~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
UNIPUR·CP flexible at low temperature. with customer markings, halogen-free. ~
ME01
wear resistant, robust, screened, EMC-preferred type, meter marking
Part no. No.c:ores x outer" Cop. weight AWG·NO. Part no. No.c:ores x outer" cop. weight AWG·NO.
approx. cross-sec:. approx.
1936_ cross-sec:. approx. mm weight kg/km 17 1958_ approx. mm weight kg 1 km
1937_ 17 1959_
1938_ mm• kg/km 65.0 17 1960_ kg/km 129,0
1939_ 76.0 17 1961_
1940_ 2 X1 7.1 50.0 89.0 17 1962_ 10.0 96.0 158.0
1941_ 17 1963_ 10,7 144.0 196.0
1942_ 3G1 7.4 60.0 108.0 17 1964_ 241,0
1943_ 141,0 17 1965_ 317,0
1944_ 4G1 8,1 71,0 187,0 17 1966_ 11.9 148.0 496,0
1945_ 17 1967_
1946_ 5G1 8,8 88.0 240,0 17 1968_ 13.2 181.0 158,0
1947_ 16 1969_
1948_ 6G1 9,7 97.0 335,0 16 1970_ 16,0 255.0 261.0
1949_ 484.0 16 1971_ 316,0
1950_ 7G1 10,7 111.0 16 1972_ 19.8 441.0 384.0
1951_ 627.0 16 1973
1952_ 12 G 1 12,9 184.0 738,0 16 1974_ 11.8 120.0 592.0
1953_ 16 1975_ 259,0
1954_ 18 G 1 15,7 260.0 97,0 16 1976 12.4 174.0
1955_ 119,0 16 1977_ 394.0
1956_ 25 G 1 19,3 349.0 16 1978_ 13,8 230.0 483,0
1957_ 21,6 486.0 152.0 16 1979_
34 G 1 168.0 15.6 273.0 592.0
218,0 18,9 316.0 714,0
41 G 1 23.3 531,0 243,0
317,0 576.0
2 X 1 ,5 8.4 63.0 13.4 173.0 729.0
481.0 914.0
3 G 1,5 8.8 80.0 674,0 14.3 240.0 960,0
9.8 97,0
4 G 1,5 881.0 16,0 305.0 1813.0
1027.0 1827,0
5 G 1,5 10,9 119.0 17,9 439.0
12.1 121,0 21,6 505,0
6 G 1,5
7 G 1,5 13,2 147.0 18.1 350.0
12 G 1,5 16,5 267,0 20.2 535.0
18 G 1.5 19.6 374.0 22.5 592.0
25 cG 1. 5 24,2 526.0 20.6 585.0
34 1. 5
41 c 1.5 27.0 629.0 23.0 740.0
29,3 801,0
25.6 895.0
Dimensions and specifications may be changed without prior notice. <RA02l
Terminations and straight-through joints
Telephone calbes
Low voltage
Medium voltage
Accessories
You can find terminations and straight-throughjoints in our catalog Cable Accessories.
Request it now at www.hitechcontrols.com
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
PUR•C•PUR cu-screened, extrem conditions, halogen-free, EMC·preferred type, meter
marking
H ELUKABEL PUR-C-PUR 5G1,5 QMM I 22367 450fl50 V 001042055 C€
RoHS
Technical data Cable structure Properties
• Special PUR control cables. screened. • Bare copper. fine wire conductors. bunch • High f lexibility at low temperatures
adapted to DIN VDE 0250 stranded to DIN VDE 0295 cl. 5. BS 6360
cl. 5 and IEC 60228 cl. 5 • High abrasion resistance
• Temperature range
-40 oc to +80 oc • Special PUR insulation • Break and cut resistant
• Nominal voltage • core identification according to • Tear resistant
Uo/U 300/500 V until 1 mm2 DIN VDE 0293-308 • Resistant to
Uo/U 450/750 V from 1,5 mm2
• Green-yellow earth core (3 cores and above> Oils and fats
• Test voltage Coolant and chemicals
• Cores stranded in layers with optimal Non-alcoholic f uels and kerosene
until1 mm2 2000 v lay-length Atmospheric influences
from 1,5 mm2 2500 v
• Foil taped uv-radiation
• Insulation resistance • Copper braided screening with 80-85%
m in. 20 MOhm x km Oxygene and ozone
coverage Microbes and rotting
• Mutual capacitance <800 Hzl Sea and waste water
core/core approx. 150 pF/m • PUR outer jacket Vibrations
core/screen approx. 320 pF/m • Colour grey (RAL 7032> Acids and Lyes
• Minimum bending radius • with meter marking, change-over in 2011 • The materials used in manufacture are
flexing 10x cable 0 cadmium-free and contain no silicone and
fixed installation 5x cable 0 f ree from substances harmful to the
wetting properties of lacquers
• Radiation resistance
up to 100x106 cJ/kg Cup to 100 Mradl Note
• coupling resistance • G =with green-yellow earth core;
x =without green-yellow earth core (OJ.
max. 250 Ohm/km
• AWG sizes are approximate equivalent
values. The actual cross-section is in mm2.
Application
PUR-C-PUR screened cables are well suited as data transfer and connection cables for the machine and motor industries due to the good
level of copper screening which blocks strong electrical disturbances.
This cable type has proven to be especially suited to use in extreme weather and environmental conditions due to its good thermal and
chemical properties. (Temperature range -40 octo +80 ocl. In addition to this it also possesses excellent mechanical properties. e.g. pressure
=resistance and good abrasive resistant qualities. all of w hich go to guarantee a long life.
EMC Electromagnetic compatibillity
<To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
E=The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x outer Ill Cop. Weight AWC·NO. Part no. No.core s x Outer Ill Cop. Weight AWC· No.
cross-sec. approx. mm w eight approx. approx.
mm2 kg / km 18 22364 approx. mm w eight kg / km 16
kg / km 18 22365 16
2 X0,75 65.0 18 22366 kg / km 101.0 16
3 00,75 6.8 40.0 80.0 18 22367 125.0 16
7.4 52.0 95.0 18 22385 8.8 63,0 150.0 14
4 G 0.75 8.0 60.0 126,0 17 22386 14
5 G0.75 8.8 71.0 17 22387 9.3 80.0 --w21.0o,0 14
6 G0,75 9.5 80.0 150.0 17 22388 169,0 14
7 ,3 50,0 80,0 17 10.3 97.0
2 X1 7.7 60.0 225.0
3G1 8.3 71,0 95.0 11 ,2 119,0 275,0
4G1 9.2 88,0 106,0 ~2
5G1 149,0 96,0
10,8 144,0
12.0 148.0
13,2 181.0
Dimensions and specifications may be changed without prior notice. !RA02l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-500 HMH
MECAFLEX® 500
JZ-600 HMH
JB-750 HMH
(H)03 Z1Z1·F
(H)05 Z1Z1·F
JZ-500 HMH·C
MECAFLEX® 500-C
JZ-600 HMH·C
JB-750 HMH·C
Photo: HELUKABEL"
Halogen-free control Cables
In all locations, due to damages of large amount The most important advantages:
of materials and more of importance to protect • No fire propagation from point of f ire
human life and technical equipment against • Functionallity for important systems
damages caused by fire and also for technical • No corrosion and damage caused by released
enquiries of insurance, the installation of
halogen-free security cables are required . corrosive gases and vapours
You will find on the following pages the • Protection of human life and valuable materials,
instructions for installation as well as the test especially for high quality machines, EDP
methods and laying instructions for the halogen-
free security cables. systems etc.
• Prevention of heavy and unexpected
subsequent damages
• Low smoke density helps rescue and fire
extinguishing
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-500 HMH flexible control cable, halogen-free, extremely fire resistant, II ~,
ME01
oil resistant11• meter marking
HELUKABEL JZ-500 HMH 2001 QMM 111251 3001500 V halogen..fr. . 001042610 C(
Ro~
Technical data Cable structure Properties
• Halogen-free flexible control cable, core • Bare copper, fine wire conductors, to • 11For t he critical applications we advise for
construction adapted to DIN VDE 0281 DIN VDE 0295 cl. 5, BS 6360 cl. 5 and consu lt a tion
part 14 and DIN VDE 0281 part 13 IEC 60228 cl. 5
• The materials used in manufacture are
• Temperature range • Core insulation of halogen-free compound cadmium-free and contain no silicone and
flexing -15 octo +70 oc Tl6, to E DIN VDE 0281 part 14 free from substances harmful to the
wetting properties of lacquers
fixed installation -40 octo +70 oc • Black cores w ith white continuous
• Nominal voltage UoiU 3001500 V numbering to DIN VDE 0293 Tests
• Flame test to VDE 0482-332-3, BS 4066
• Test voltage 2000 v • Green-yellow earth core in the outer layer
<3 cores and above> part 31 DIN EN 60332-311EC 60332-3
• Minimum bending radius <equivalent DIN VDE 0472 part 804 test
flexing approx. 12,5x cable 0 • Cores stranded in layer with optimal method Cl
fixed installation approx. 4x cable 0 lay-length • self-extinguishing and f lame retardant
according to VDE0482-332-1-2, DIN EN
• Radiation resistance • Halogen-free sheath compound TM7, to 60332-1-21 1EC 60332-1 <equivalent
up to 100x106cJikg <up to 100 Mradl E DIN VDE 0281 part 14 DIN VDE 0472 part 804 test method Bl
• corrosiveness of combustion gases
• Outer jacket colour grey <RAL 7001l according to VDE 0482 part 267 1
• with meter marking, change-over in 2011 DIN EN 50267-2-211EC 60754-2 <equivalent
DIN VDE 0472 part 813)
• LSOH = Low Smoke Zero Halogen-f ree. • Halogen-free according to VDE 0482
part 2671 DIN EN 50267-2-11 1EC 60754-1
<equivalent DIN VDE 0472 part 815l
• Smoke density according to VDE 0482
part 1034-1 +2 IIEC 61034-1+2 I
DIN EN 61034·1+2 I BS 7622 part 1+2
<equivalent DIN VDE 0472 part 816l
Note
• G = with green-yellow earth core;
x =without green-yellow earth core <OZl.
• Please note the clean room qualification
when ordering.
• screened analogue type:
JZ-500 HMH-C, see page A 71
Application
Halogen-free. flame retardant cables are used as measuring and control cable in machine tools, conveyor belts. production lines as well as
in plant installations, in air-conditioning and steel production works. For fixed installation or flexible application. directed w ithout forcing by
casual, not constantly recurring free movements and without tensile stress. for medium mechanical strain. This cable is suitable for t he
application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonry excluding in
direct laying in shaked or stamped concrete. not suitable for imbedding in solidified or compressed concrete.
<E = The product is conformed with the EC Low-Voltage Directive 20061951EG
Part no. No.cores x Outer" Cop. Weight AWC·No. Part no. No.cores x outer" Cop. weight AWC·No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
11201 mm• kg / km 20 11210 mm• kg / km 20
11202 kg/km 20 11211 kg/km 20
11332 2 x0,5 4,9 9,6 43.0 20 11212 18 G0,5 204,0 20
11203 3G0,5 50,0 20 11213 20 G0,5 11 ,0 86.0 227,0 20
11333 3 x0,5 5.2 14,4 20 11214 11,5 96.0 283,0 20
11204 4 GO,S 5,2 14,4 50.0 20 11215 25 G0.5 12,9 120.0 324,0 20
11334 4 xo.s 60.0 20 11216 30 G0,5 367,0 20
11205 5,6 19,0 60.0 20 11217 34 G0,5 13,8 144,0 381,0 20
11206 SGO.S 71,0 20 11218 37 G0,5 417,0 20
11207 sxo.s 5,6 19,0 71 ,0 20 11219 41 G0,5 14,9 163.0 454,0 20
11208 7 co.s 84.0 20 11220 42 GO,S 519,0 20
11209 8G0,5 6,3 24,0 101 , 0 20 50 G0,5 14,9 178,0
10 G0.5 121,0 61 G0,5 635.0
12 G0,5 6,3 24,0 142,0 16,1 197.0 694,0
16 G0.5 183.0 65 G0.5
6,9 33,6 16.1 202.0
17,9 240.0
7,4 38.0 19,0 293,0
8,3 48,0
19.7 312,0
8,8 58,0
10.2 76,0
Continuation •
c HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
JZ·SOO HMH flexible control cable, halogen-free, extremely fire resistant, ~~ ~
ME01
oil resistant11, meter marking
Part no. No.cores x outer" Cop. Weight AWC-No. Part no. No.cores x outer" Cop. Weight AWC•NO.
cross·sec. approx. mm weight approx. cross·sec. approx.mm weight approx.
11221 mm2 kg/km 18 11277 kg/km 14
11222 kg/km 18 11278 kg/km 14
11335 2 X0,75 47,0 18 11279 118,0 14
11223 3 G0,75 5.3 14.4 18 11280 7,8 48,0 151,0 14
11336 5.6 21.6 56.0 18 11281 181,0 14
11224 3 X0.75 5.6 21 ,6 56.0 18 11282 8.3 72.0 14
11337 4 G0.75 6,3 29.0 69,0 18 11283 9.2 96,0 224.0 14
11225 6.3 29.0 69,0 18 11284 10,1 120.0 316.0 14
11338 4 X0.75 6,9 36,0 83,0 18 11285 11.2 168,0 370.0 14
11226 5 G0,75 18 11286 451.0 14
11227 5 X0,75 6.9 36.0 83.0 18 11287 12.3 192.0 499.0 14
11228 7.5 50.0 114.0 18 11288 13.9 240,0 14
11229 7 G0.75 7.5 50.0 114,0 18 11289 14.8 288.0 720.0 14
11230 7 x0.75 8,2 58,0 18 11290 17,1 384,0 769.0 12
11231 8 G0,75 136.0 18 11291 911 ,0 12
11232 9.2 72.0 172.0 18 11292 18.2 432.0 1047.0 12
11233 10 G0.75 9,8 86,0 183,0 18 11293 19.1 480,0 12
11234 12 G0,75 11,4 115.0 241 ,0 18 11294 21.6 600,0 1280.0 12
11235 16 G0.75 12.2 130,0 18 11295 199,0 12
11236 12.7 144.0 266.0 18 11296 23.0 720.0 247,0 12
11237 18 G0.75 14.3 180.0 291,0 18 11297 9,3 77,0 12
11238 20G0.75 15.3 216,0 374,0 18 11298 9,8 115,0 299.0 12
11239 25 G0.75 16.7 245,0 450,0 18 11299 369.0 12
11240 16,7 260.0 517,0 18 11300 11.0 154.0 463,0 10
11241 30G0.75 18,0 296,0 541 .0 17 11301 12,3 192.0 601 ,0 10
11242 34 G0.75 611,0 17 11302 13.6 269.0 698,0 10
11339 18.0 302.0 17 11303 14.6 307.0 10
11243 37 G0.75 19.8 360,0 621 .0 17 11304 17.8 384,0 790.0 10
11340 41 G0,75 21.2 439.0 742,0 17 11305 18.2 461.0 1130,0
11244 42 G0.75 21.7 468.0 17 11306 20.6 614,0 1280,0 8
11245 853.0 17 11307 21 ,9 691 ,0
11246 50G0.75 5,6 19.2 909.0 17 11308 266.0 8
11247 61 G0.75 5.9 29.0 63.0 17 11309 11.0 115.0 360.0 8
11248 5.9 29.0 17 11310 11.9 173.0 429,0 8
11249 65G0.75 6,6 38.4 74.0 17 11311 13.0 230,0 8
11250 2x 1 6,6 38,4 74.0 17 11312 14.5 288.0 529.0 6
11251 3G1 90.0 17 11313 16,2 403,0 631.0 6
11252 3x1 7.3 48.0 90.0 17 11314 440,0 6
11253 4G1 8,1 67.0 109,0 17 11315 14.0 192.0 550,0 6
11254 4x1 8.7 77.0 151 ,0 17 11316 14,8 288,0 6
11255 5G1 9.8 96,0 17 11317 16.4 384,0 708.0
11256 7G1 10,4 115.0 184.0 17 11318 18.3 480.0 862.0
11257 8G1 12.3 154.0 224,0 17 11319 20.2 672.0 1124,0
11258 10G1 12.9 173,0 17 11320 16.8 307.0
11259 12 G 1 13,7 192,0 243.0 17 11321 18.2 461 ,0 642,0
11260 16G1 314.0 16 11322 20.0 614.0 830.0
11261 18G1 15.4 240,0 361.0 16 11323 22.6 768.0 1060,0
11341 20G 1 17.9 326,0 387.0 16 11324 24.8 1075,0 1270,0
1 1262 25G 1 17.9 355,0 496.0 16 11325
11263 34 G1 19,4 394,0 670,0 16 11326 22.2 720.0 1794.0
11264 37 G1 19,4 403.0 16 11327 24,9 960.0 1190,0
11265 41 G1 21,2 480.0 713,0 16 11328 27,7 1200.0 1594,0
11266 22.5 586,0 784,0 16 11329 25.6 1008.0 2014,0
11267 42 G1 23.5 628,0 16 11330 28.4 1344,0
11268 50G1 824.0 16 11331 31.7 1680.0 1590,0
11269 61 G1 6.4 29.0 952.0 16 30.9 1440,0 2200.0
11270 65G 1 6.8 43.0 1140.0 16 34,2 1920.0
11271 6.8 43.0 1201 ,0 16 38.3 2400,0 2693.0
11272 2 X1.S 7.4 58.0 16 36.5 2016,0 2571.0
11273 3G 1,5 8.3 72.0 70.0 16 40,3 2688.0 3087.0
11274 3 X1,5 9.2 101,0 94,0 16 45.3 3360,0 3980.0
11275 4G 1,5 9.9 115.0 94,0 16 41 ,1 2736,0 3207,0
11276 10,9 144,0 16 45.8 3648.0 4077.0
5G1.5 12,0 173.0 112.0 50,7 4560,0 5501,0
7 G 1,5 13.9 230.0 141,0 4708,0
14.6 259.0 191,0 41:"0 3456,0
8G 1.5 15.5 288.0 224,0 51.4 4608.0 5590,0
10G 1.5 17.4 360,0 6972,0
12 G1.5 20.2 490.0 282.0
16 G1,5 20.2 533.0 311,0 5515,0
24.2 720.0
18 G1.5 25.8 878.0 392.0 7100.0
20 G1,5 26.7 936.0 450.0
497.0
25 G1.5 630.0
34 G1.5 842.0
37 G1.5 897.0
1277.0
soc 1.5 1460.0
1612.0
61 G1.5
65 G1.5
Dimensions and specifications may be changed without prior notice. !RA03l
Quality assurance inspections with the aid of
a stereo microscope at our Windsbach factory.
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
MECAFLEX® 500 halogen-free, flame retardant, oil-resistant,
uv-resistant. flexible. meter marking
- --· . HELUKABEL MEGAFLEX- 600 2& G 1,5 QMM /13427 3001500V E170315 'M AWM STYLE ( €
20939 c'M AWM 1111 AlB ao·c &OOV FT1 halogen-free FRNC oH ........nt 001061280
-~·
IRoHS i
Technical data Cable structure Properties
• Halogen-free flexible control cable, • Bare copper, fine wire conductors, to • Halogen-free
core-structure adapted to DIN VDE 0281 DIN VDE 0295 cl. 5, BS 6360 cl. 5 and • Highly flame-retardant
part 14, to UL·Style 20939, UL·Std . 758
IEC 60228 cl. 5 • Resistant to oils and greases
• Temperature range • Core insulation of halogen-free special • Resistant to UV and weathering
flexing -30 octo +80 oc
fixed installation -40 oc to +80 •c polymer • Hydrolysis resistant
• Nominal voltage UoiU 3001500 V • Black cores w ith white continuous • Flexible, abrasion- and wear-resistant
numbering to DIN VDE 0293
• Test voltage 3000 v • Ozone-resistant
• Green-yellow earth core in t he outer layer
• Minimum bending radius (3 cores and abovel • Recycleable
flexing approx. 10x cable 0 Tests
fixed installation approx. 4x cable 0 • Cores stranded in layer with optimal • Flame test to VDE 0482-332-3/ BS 4066
lay-length
• Flexible part 31
Alternate bending test according to DIN • Outer sheath, halogen-free special polymer DIN EN 60332-3/IEC 60332-3-24 (previously
VDE 0281-2 DIN VDE 0472 part 804 test method Cl
• Outer jacket colour g rey (RAL 7001 l • Self-extinguishing and flame retardant
Approved to UL/CSA according to DIN VDE 0482·332-1-2, DIN
see section N, page N 54 • with meter marking, change-over in 2011 ENIIEC 60332-1 <previously DIN VDE 0472
part 804 test method B>
• The materials used in manufacture are • Corrosiveness of combustion gases
cadmium-free and contain no silicone and according to NF X 10-702
are free from substances harmful to the
wetting properties of lacquers • Halogen-free according to DIN VDE 0482
part 267I EN 50267·2·11 IEC 60754·1
• LSOH =Low Smoke Zero Halogen -free. (equivalent DIN VDE 0472 part 815l
• smoke density according to DIN VDE 0482
part 1034·1+2, DIN EN 61034·1+21
IEC 61034·1+2, BS 7622 part 1+2 (previously
DIN VDE 0472 part 816>
• Oil-resistant to DIN EN 60811-2-1
• Hydrolysis-resistant to DIN EN 61234-1
• Ozone-resistant to DIN EN 60811-2-1 I
DIN VDE 0281-2
Note
• G = with green-yellow earth core;
x =without green-yellow earth core (0Zl.
• Also available as a 0,611 kV cable u nder
consideration of economical minimum
quantities. MEGAFLEX® 600
• screened analogue type:
MEGAFLEX® 500-C, see page A 73, N 56
Application
For fixed installation or flexible application, with free movements w ithout forcing which do not constantly recur and w ithout tensile stress.
for h igh mechanical strain.As a measuring and control cable primarily in machinery and plant contruction. in building and air-conditoning
systems, in warehousing and converying systems, in ship-building and for regenerative types of energy such as in the construction of wind
power stations. Especially well-suited for use in public buildings, such as airports and train stations, w here personal injuries and subsequent
damage must be prevented in the event of a fire. CE= The product is conformed with t he EC Low-Voltage Directive 20061951EG.
Part no. No.cores x Outer e Cop. Weight AWC·NO. Part no. No.cores x Outer e cop. Weight AWC·NO.
approx.
13344 cross-sec. approx. mm weight approx. 20 13356 cross-sec. approx. mm weight kg/ km 20
13345 kg/ km 20 13357 20
13346 mm• kg/ km 20 13359 mm• kg/km 204.0 20
13347 43,0 20 13360 227,0 20
13348 2 X 0,5 4.8 9.6 20 13361 18 G 0,5 10,7 86.0 283,0 20
13349 50,0 20 13362 324,0 20
13350 3 00,5 5,1 14.4 50,0 20 13363 20 G0,5 11,2 96,0 20
133S1 20 13364 367.0 20
13352 3 X 0 .5 5,1 14,4 60.0 20 13365 25 cG 0.5 12,7 120.0 381.0 20
13353 60,0 20 13366 30 0.5 417,0 20
13354 4 00,5 5,7 19,0 20 13367 13.5 144,0 454,0 20
13355 71.0 20
4 X 0,5 5,7 19,0 71,0 34 G0.5 14,5 163,0 519.0
84,0 635.0
5 G0.5 6,2 24.0 101,0 37 cG 0,5 15,0 178,0 694,0
121,0 41 c 0,5
5 X 0 ,5 6,2 24,0 42 0.5 15.8 197,0
142.0
700.5 7,4 33.6 183,0 15,8 202,0
800.5 8,0 38,0 50 G0,5 17.3 240,0
10G 0.5 8.8 48,0 61 G 0,5 19.4 293.0
12 cG 0.5 9,1 58,0 65 G0,5 19,4 312.0
16 0,5
10,0 76.0
Continuation •
c HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
MECAFLEX® 500 halogen-free. flame retardant, oil-resistant, ~ ~ 1•1
uv-resistant. flexible, meter marking
Part no. No.cores x Outer B cop. weight AWC•NO. Part no. No.cores x Outer" cop. weight AWC·NO.
approx. approx. mm weight approx.
13368 approx. mm w eight kg / km 19 13433 kg / km
13369 19 13434
13370 kg / km 47.0 19 13435 kg t km 118.0
13371 56,0 19 13436 151.0
13372 5.2 14.4 56,0 19 13437 7.6 48,0 181.0
13373 69,0 19 13438 224,0
13374 5 ,5 21,6 69.0 19 13439 8.3 72.0 316,0
13375 83.0 19 13440
13376 5.5 21 ,6 83.0 19 13441 9.1 96.0 370.0
13377 114,0 19 13442 451 .0
13378 6.2 29.0 19 13443 10.2 120.0 499,0
13379 114.0 19 13444
13380 6.2 29.0 136,0 19 13445 12.1 168,0 720.0
13381 172,0 19 13446 769,0
13382 6,8 36.0 19 13447 13,2 192,0
13383 183,0 19 13448 911.0
13384 6.8 36.0 241 .0 19 13449 14,6 240.0 1047,0
13385 266.0 19 13450 1280.0
13386 8,1 50,0 291 .0 19 13451 15.2 288.0 199,0
13387 374,0 19 13452
13388 8.1 50,0 19 13453 16.8 384.0 247,0
13389 450.0 19 13454 299,0
13390 8.9 58.0 517,0 19 13455 18.1 432.0 369,0
13392 541,0 19 13456 463,0
13393 9.6 72.0 18 13457 19.0 480.0 601,0
13394 611.0 18 13458 698,0
13395 9,9 86.0 621.0 18 13459 22.2 600.0 790,0
13396 742.0 18 13460 1130,0
13397 11 ,2 115,0 853.0 18 13461 22.9 720.0 1280,0
13398 909,0 18 13462
13399 11.9 130,0 18 13463 9.2 77,0 266,0
13400 63,0 18 13464 360,0
13401 12.6 144.0 74,0 18 13465 9,9 115,0 429.0
13402 74,0 18 13466
13403 14.1 180,0 90,0 18 13467 11,0 154,0 529.0
13404 90,0 18 13468 631,0
13405 15,4 216.0 109,0 18 13469 12,1 192,0
13406 151,0 18 13470 440.0
13407 16,4 245,0 184,0 18 13471 13,3 269,0 550.0
13408 224,0 13472 708.0
13409 17,2 260,0 243,0 18 13473 15,9 307,0 862.0
13410 314,0 18 13474 1124,0
13411 17,6 296.0 361,0 18 13475 17,3 384,0
13412 387,0 18 !13476 642,0
13413 17.6 302.0 496,0 18 13477 18,3 461,0
13414 670,0 18 13478 830.0
13415 19,8 360.0 713,0 16 13479 20.2 614.0 1060,0
134'16 784,0 16 13480 1270,0
13417 20.9 439,0 824,0 16 13481 21,8 691,0 1794,0
13418 952,0 16 13482
13419 21,5 468.0 1140,0 16 13483 10,8 115.0 1190,0
13420 1201,0 16 13484 1594,0
13421 5,5 19,2 16 13485 11,7 173.0 2014,0
13422 70.0 16 13486
13423 6,0 29,0 94,0 16 13487 13,0 230,0 1590,0
13425 94,0 16 13488 2200,0
13426 6.0 29,0 112,0 16 13489 14,5 288.0 2693,0
13427 141,0 16
13428 6,6 38.4 191,0 16 16.0 403,0 2571,0
13429 224.0 16 3087,0
13430 6,6 38.4 282,0 16 14,0 192.0
13431 311.0 16 3980.0
13432 7,2 48,0 392.0 16 15,0 288.0 3207.0
450,0 16 4077.0
8,6 67,0 497.0 16.8 384.0 5501 ,0
630,0 4708,0
9.4 77,0 842,0 18.7 480.0 5590,0
897.0 6972,0
10,4 96,0 1277,0 20.6 672,0
1460.0 5515.0
10,7 115,0 1612,0 16.5 307.0 7100,0
6279,0
12,0 154,0 17,6 461,0 7781,0
12.7 173,0 19,7 641,0
13,5 192,0 21,9 768,0
15,2 240,0 24.4 1075,0
17.4 326,0 22.5 720,0
18.4 355,0 25.2 960,0
18,9 394,0 27,9 1200.0
18,9 403,0 26,3 1008,0
21,0 480,0 29.2 1344.0
22,2 586,0 32,7 1680.0
22.8 628,0 31.5 1440.0
6,1 29.0 35,0 1920,0
6,5 43.0 38.7 2400.0
6.5 43,0 37.2 2016,0
7.2 58.0 42.2 2688.0
7,9 72,0 47,4 3360.0
9,5 101,0 42"71 2736,0
10.4 115.0 47,0 3648,0
11 , 3 144,0
52,3 4560,0
11,7 173,0
46,6 3456,0
13.3 230,0
51.4 4608,0
14,0 259,0
53.0 4320.0
14,9 288,0
59.0 5760.0
16,8 360.0
19,4 490,0
20,2 533,0
23.4 720,0
24,8 878,0
26,0 936,0
Dimensions and specif ications may b e changed with out p rior notice . <RA031
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols .com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil ~
ME01
resistant1 1, 0,6/1kV, meter marking
'-'"""' __. . =~ 1
~=-- ----'
' - HELUKABEL JZ-600 HMH 25G 1,5 QMM /12770 0.6/1kV halogen-free 001047001 CE
Ro@
Technical data Cable structure Properties
• Halogen-free. flexible control cable. • Bare copper. fine wire conductor to • 1l For critical applications recommend you
DIN VDE 0295 cl. 5, BS 6360 cl. 5 and/or request a consultation
adapted to DIN VDE 0281 part 14 and IEC 60228 cl. 5
DIN VDE 0281 part 13 • The materials used in manufacture are
• Temperatur e range • Halogen-free polymer core insulation. Tl6 cadmium-free and contain no silicone and
ace. to E DIN VDE 0281 Part 14 free from substances harmful to t he
flexing ·15 •c to +70 •c wetting properties of lacquers
• Black cores w ith continuous white
fixed ·40 •c to +70 •c numbering according to DIN VDE 0293 Tests
• Flame test ace. to VDE 0482·332·3 BS 4066
• Nominal voltage Uo/U 0,6/1 kV • Green-yellow earth core in the outer layer
<3 cores and abovel Part 3/ DIN EN 60332·3/IEC 60332·3 <as per
• Test voltage 4000 v DIN VDE 0472 Part 804 Test Method Cl
• Cores stranded in layers with optimal • self-extinguishing and f lame retardant
• Minimum bending radius lay-length according to VDE 0482·332·1·2, DIN EN
for permanent bending 60332·1·2/ IEC 60332·1 <equivalent
• Halogen-free polymer sheath. TM7 ace. to DIN VDE 0472 part 804 test method Bl
approx. 15x cable 0 E DIN VDE 0281 Part 14 • corrosiveness of corrosive gases ace. to
VDE 0482, Part 267/ DIN EN 50267·2·2/
• Radiation resistance • Sheath colour black <RAL 9005J IEC 607542 <as per DIN VDE 0472, Part 813l
up to 100x10&cJ/kg <up to 100 Mradl • with meter marking, change-over in 2011 • Halogen-free ace. to VDE 0482. Part 2671
DIN EN 50267·2·1/IEC 60754·1 <as per
• LSOH =Low Smoke Zero Halogen-free. DIN VDE 0472, Part 815l
• Smoke density according to VDE 0482
part 1034·1+2 I IEC 61034·1+2 I
DIN EN 61034·1+2 I BS 7622 part 1+2
<equivalent DIN VDE 0472 part 816>
Note
• G = with green-yellow earth core;
x =without green-yellow earth core <OZJ.
• screened analogue type:
JZ-600 HMH-C, see page A 75
Application
Halogen -free. flame retardant cables are used as measuring and control cable in machine tools, conveyor belts. production lines as well as
in plant installations. in heating and air-conditioning systems and steel production works. For fixed installation or f lexible application. directed
without forcing by casual. constantly recurring free movements and without tensile stress. for medium mechanical strain. This cable is
suitable for the application in dry, damp and wet environments and outdoors <fixed installation) and for laying on. in and under plaster as
well as in concrete and masonry excluding in d irect laying in vibration. compacted or compressed concrete.
EMC = Electromagnetic compatibillity
C& The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cor es x Outer" Cop. Weight AWC·NO. Part no. No.cores x Outer" Cop. Weight AWC·No.
cross-sec. approx. mm w eight approx. cross-sec. approx. mm w eight approx.
12723 mm• kg 1 km 20 12735 mm• kg 1 km 18
12724 kg l km 20 12736 kg l km 18
12725 2 X0 ,5 57,0 20 12737 2 x0,75 68,0 18
12726 3G0,5 6.3 9.6 69,0 20 12738 3 G0,75 6.6 14,4 77,0 18
12727 3 x0,5 6.6 14,4 69,0 20 12739 3 X0,75 18
12728 4G0,5 6.6 14,4 104,0 20 12740 4 G0,75 6.9 21.6 77.0 18
12729 4 x0.5 7.2 19,0 104.0 20 12741 4 X 0,75 6,9 21.6 136.0 18
12730 5G0,5 7.2 19.0 121,0 20 12742 5 G0,75 136.0 18
12731 5 x0,5 8.0 24,0 121 ,0 20 12743 7.5 29.0 152,0 18
12732 7 G0.5 8.0 24,0 145,0 20 12744 5 x0.75 7,5 29.0 18
12733 10 G0,5 8.7 33,6 186.0 20 12745 7 G0.75 8.4 36,0 152.0 18
12734 10,6 48,0 224,0 20 12746 10 G0.75 208,0 18
12 G0.5 8.4 36.0 250,0
18 G 0,5 11,4 58.0 292.0 12 G0.75 9,3 50,0 271,0 Continuation •
25 G0,5 357,0 18 G0.75
13.8 86.0 25 G0,75 11,1 72.0 387.0
16,1 120,0 12,2 86,0 498.0
14,5 130.0
17,2 180.0
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil ~
ME01
resistant11, 0,6/1kV, meter marking
Part no. No.cores x Outer e Cop. w eight AWC·No. Part no. No.cores x Outer e Cop. Weight AWC•NO.
cross-sec. approx. approx.
12747 approx. mm weight kg l km 17 12783 approx. mm weight kg 1 km
12748 17 12784
12749 kg 1 km 82.0 17 12785 kg l km 255,0
12750 99.0 17 12786 319,0
12751 7.0 19.2 99.0 17 12787 115,0
12752 140,0 17 423.0
12753 7,4 29.0 140,0 17 ~ 2788 154,0 380,0
12754 160,0 17 441 ,0
12755 7.4 29.0 160,0 17 12789 192.0 657,0
12756 217,0 17 12790
12757 8.2 38.4 271,0 17 12791 173,0 668.0
12758 17 12792 796,0
12759 8.2 38.4 301 .0 16 12793 230,0
12760 417,0 16 12794 972.0
12761 9.2 48,0 16 12795 288,0
12762 576.0 16 12796 832.0
12763 9.2 48,0 97,0 16 12797 288.0 1122.0
12764 16 12798 1604.0
12765 9,9 67.0 119,0 16 12799 384.0 1457,0
12766 119,0 16 12800 1611,0
12767 11.9 96,0 148,0 16 12801 480.0
12768 148,0 16 12802 2070.0
12769 13,1 115,0 172,0 16 12803 461.0 1914,0
12770 172,0 16 12804
12771 15.7 173,0 14 614,0 2424.0
12772 243.0 14 2970,0
12773 18.6 240,0 311 ,0 14 768.0
12774 14 3467,0
12775 8,2 29,0 392,0 14 720,0 4491,0
12776 529,0 14
12777 8.6 43,0 14 960.0 6170,6
12778 741 ,0 14
12779 8,6 43.0 160,0 14 1200.0 7618,0
12780 177,0 14
12781 9.6 58,0 177,0 14 1008,0
12782 209,0 14
9,6 58,0 209,0 1344,0
10,7 72,0 272.0 1680,0
272.0
10,7 72,0 340,0 1920,0
561,0
11.6 101,0 799,0 2688,0
940,0
15,2 144,0 1121.0 3648,0
15,5 173,0 4608,0
18,6 259,0
22,5 360,0
9,6 48,0
10,1 72,0
10,1 72.0
11.2 96,0
11,2 96,0
12,5 120.0
12,5 120.0
13,8 168,0
16,7 288,0
18,3 432,0
22 .0 480,0
26,2 600,0
Dimensions and specifications mav be changed without prior notice. !RA03J
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
CHJ03 Z1Z1·F halogen-free, meter marking
HELUKABEL (H)03 Z1 Z1-F C(
IRoHS I
R oHS] HELUKABEL (H)03 Z1Z1-F
Technical data Cable structure Properties
• flexible halogen-free control cable • Bare copper. fine wire conductor. bunch • Tests
according E DIN VDE 0281 part 14 pr HD stranded to DIN VDE 0295 cl. 5. BS 6360 Tested for flame retardation to VDE
cl. 5, IEC 60228 cl. 5, HD 383 0482-332-1-2. DIN EN 60332-1-2/
21.1451 IEC 60332-1 <equivalent DIN VDE 0472
• Temperature range • Insulating jacket thermoplastic compound. part 804 test method Bl
Tl6 according to DIN VDE 0281 part 14,
flexing -5 octo +70 oc appendix A • smoke density to VDE 0482 part 268-2
• Halogen-free to HD 21.14 appendix C
fixed installation -40 oc to +70 oc • Core identification according to • The materials used in manufacture are
• Nominal voltage DIN VDE 0293-308
cadmium-free and contain no silicone and
Uo/U 300/300 V • Green-yellow earth core. 3 cores and above f ree f rom substances harmful to the
• Test voltage 2000 V • Core stranded with optimal lay-length wetting properties of lacquers
• Breakdown voltage min. 4000 v • Outer sheath, thermoplastic compound, Note
TM7 according DIN VDE 0281 part 14,
• Minimum bending radius appendix B • G=with green-yellow earth core;
approx. 7,5x cable 0 x =without green-yellow earth core.
• Jacket colour by request
• Radiation resistance • AWG sizes are approximate equivalent
UP tO 20X106 CJ/kg (UP to 20 Mradl • with meter marking, change-over in 2011 values. The actual cross-section is in mm2•
• Colour code:
0 = RAL 9005, black
1 = RAL 9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL 1021. yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL 4005, violet
9 = RAL 7001/7032, grey
• Please add the individual part no. for order
with the identification colour code.
Further colours on request.
Application
These cables may be used when halogen-free. low smoke and corrosive gas properties are required in case of fire. For low mechanical
demands in the house. kitchen and office. for small equipment such as. for example. office machines. radios. table and stranded lamps.
Not suitable for:
Cooking and heating equipment. use in high temperature areas <for example. in lighting equipment>. outside use. industrial use or idustrial
electrical tools. cables with a nominal cross-section of 0,75 mm2 comply with the same recommendations as for cable <Hl05 Z1Z1-F.
CE:= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outer 0 cop. Weight AWG- No. Pa rt no. No.cores x outer 0 Cop. Weight AWG - No.
cross-sec. approx. mm w eight a pprox. cross-sec. approx. mm weight approx.
3233_ mm2 kg / km 20 3236_ kg / km 18
3234_ kg / km 20 3237_ mm2 kg / km 18
3235_ 2 X0.5 39.0 20 3238_ 2 X0,75 5,4 14,4 47.0 18
3 G0.5 5.0 9.6 46.0 3 G 0,75 55.0
4 GO,S 5,3 14.4 56.0 4 G0,75 5.7 21.6 69.0
5.8 19.2 6,3 29.0
Dimensions and specifications may be changed without p rior notice. <RA03l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
(H )05 Z1 Z1•F halogen-free. meter marking
HELUKABEL (H)OS Z1 Z1-F CE;
RoHS I
((
Technical data Cable structure Properties
• flexible halogen-free control cable • Bare copper, f ine wire conductor. bunch • Tests
according E DIN VDE 0281 part 14 stranded to DIN VDE 0295 cl. 5, BS 6360 Tested for flame retardation to VDE
pr HD 21.14 S1 cl. 5, IEC 60228 cl. 5, HD 383 0482·332-1-2, DIN EN 60332-1-2/
IEC 60332·1 <equivalent DIN VDE 0472
• Temperature range • Insulating jacket thermoplastic compound, part 804 test method Bl
flexing -5 oc to +70 oc Tl6 according to DIN VDE 0281 part 14,
appendix A • smoke density to VDE 0482 part 268-2
fixed installation -40 octo +70 oc • Halogen-free to HD 21.14 appendix C
• Nominal voltage • Core identification according to • The materials used in manufacture are
DIN VDE 0293-308
Uo/U 300/500 V cadmium-free and contain no silicone and
• Test voltage 2500 V • Green-yellow earth core. 3 cores and above free from substances harmful to the
• Core stranded with optimal lay-length wetting properties of lacquers
• Breakdown voltage min. 5000 v
• Outer sheath, thermoplastic compound, Note
• Minimum bending radius TM7 according DIN VDE 0281 part 14,
approx. 7,5x cable 0 appendix B • G =with green-yellow earth core;
x =without green-yellow earth core.
• Radiation resistance • Jacket colour by request
UP to 20X10G CJ/kg (UP to 20 Mradl • AWG sizes are approximate equivalent
• with meter marking, change-over in 2011 values. The actual cross-section is in mm2•
• Colour code:
0 = RAL 9005, black
1 = RAL9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL1021, yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL4005, violet
9 = RAL 7001/7032, grey
• Please add the individual part no. for order
with the identification colour code.
Further colours on request.
Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of f ire. For moderate mechanical
demands in the house. kitchen and office. for house equipment in damp rooms <for example: washing machines. spin-dryers and refrigerators>.
Suitable for cooking and heating equipment. providing the cable is not in contact with hot components or heat radiation.
Not suitable for:
in high temperature areas <for example, in lighting equipment>. outside buildings, in industrial or agricultural buildings, connection of
electrical power tools.
CE: The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x outer e Cop. Weight AWC· NO. Part no. No.core s x Outer B cop. Weight AWC·No.
cross-sec. approx. cro ss- se c . approx. mm w eight approx.
3027_ approx. mm w eight kg /km 18 3043_ kg / km 14
3028_ kg / km 18 3044_ mm2 kg / km 12
3029_ 58.0 18 3045_ 5G 2.S 260.0 12
3030_ 6.2 14.4 68,0 18 3046_ 2x4 12.3 120.0 12
3031 _ 6.6 21.6 81 ,0 17 3047_ 3G4 10.6 76,8 190.0 12
3032_ 7.1 29.0 17 4G4 11 ,5 115,2 242.0
3034_ 8.0 36,0 102.0 17 5G4 12,5 153.6 298,0
3035_ 67,0 17 14,1 192,0 371.0
3036_ 6.6 19.0 81,0 16
3037_ 6,9 29,0 16
3038_ 7,7 38.0 101 .0 16
3039_ 8.4 48,0 107,0 16
3040_ 7.4 29.0 14
3041 _ 8.1 43,0 87,0 14
3042_ 9.1 58.0 14
10.1 72.0 109,0
9,3 48,0 117.0
10,1 72.0 169,0
11,0 96.0 138,0
172,0
210.0
Dimensions and specifications may be changed without prior notice. (RA03l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-500 HMH-C flexible control cable, halogen-free, extremely fire II ~
MEOI
resistant, oil resistant1 1, cu-screened, EMC-preferred type
HELUKABEL JZ-$00 HMH.C 402,5 QMM /11748 3001500 V halogen-free 001042812 ( (
Technical data Cable structure Properties
• Halogen-free core flexible cont rol cable • Bare copper, f ine wire conductors, to • 1 ) For t he critical applications we advise for
adapted to DIN VDE 0281 part 14 and consultation
DIN VDE 0281 part 13 DIN VDE 0295 cl. 5. BS 6360 cl. 5 and
IEC 60228 cl. 5 • The materials used in manufacture are
• Temperature range • Core insulation of halogen-free compound cadmium-free and contain no silicone and
f lexing -15 octo +70 oc Tl6, toE DIN VDE 0281 part 14 free from substances harmful to t he
f ixed installation -40 octo +70 oc wetting properties of lacquers
• Black cores w ith white continuo us
• Nominal voltage UoiU 3001500 v n umbering to DIN VDE 0293 Tests
• Flame test to VDE 0482-332-3, BS 4066
• Test voltage 2000 v • Green-yellow earth core in the outer layer
<3 cores and above> part 31 DIN EN 50266-21 IEC 60332-3
• Minimum bending radius <equivalent DIN VDE 0472 part 804 test
f lexing approx. 12,5x cable 121 • Cores laid up in layers w ith optimal method Cl
f ixed installation approx. 4x cable 121 lay- le n g th • self-extingu ishing and fla m e retardant
according to VDE 0482-332-1-2, DIN EN
• coupling resistance • Separating layer 60332-1-21 IEC 60332-1 <equivalent
DIN VDE 0472 part 804 test m ethod Bl
max. 250 Ohmlkm • Screen b raid of t in ned copper wires. • Corrosiveness of combustion gases
• Radiation resistance coverage approx. 85% according to VDE 0482 part 267I
DIN EN 50267-2-21 IEC 60754-2 <equivalent
up to 100x106 cJikg <up to 100 Mrad> • Halogen-free sheath compound TM7, to DIN VDE 0472 part 813l
• Halogen -free according to VDE 0482
E DIN VDE 0281 part 14 part 267I DIN EN 50267-2-11 IEC 60754-1
• Jacket colour grey <RAL 7001 > <equivalent DIN VDE 0472 part 815)
• with meter marking, change-over in 201 1 • smoke density according to VDE 0482
• LSOH = Low Smoke zero Halogen -free. part 1034-1+2 I IEC 61034-1+2 I
DIN EN 61034-1+2 I BS 7622 part 1+2
<equivalent DIN VDE 0472 part 816>
Note
• G =with green-yellow earth core;
x = without green -yellow earth core <OZl.
• Cleanroom qualification tested with analog
type. Please note "cleanroom q ualified"
when ordering .
• u nscreened analogue type:
JZ-500 HMH. see page A 62
Application
Halogen-free. flam e retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation
belts. p roduction lines. In p lant construction. air-conditioning systems as well as in iro n and steel works. For f ixed installation o r for f lexing
applications. for casual. not constantly recurring f ree movement without forced motion and w ithout tensile stress f o r medium mechanical
loads. The cable is su itable for use in d ry, dam p and wet environments for installation above. on. in and beneath plaster as well as in masonry
and concrete walls except for direct embedding in vibrated. compacted o r tamped concrete. not suitable for imbedding in solid ified or
compressed concrete.
An interference-free transmission of signals and pulse in assured by the h ig h degree of screening.
EMC =Electromagnetic compatibillity
To optimise t he EMC features we recommend a large round contact of the copper braiding o n both ends.
<E= The product is conformed with the EC Low-Voltage Directive 20061951EG.
Part no. No.coresx outer til Cop. Weight AWG-No. Part no. No.cores x outer 0 Cop. Weight AWC-No.
cross-sec. approx. cross-sec. approx.
11656 mm• approx. mm weight kg/km 20 11678 mm• approx. mm weight kg/ km 18
11657 20 11679 18
11342 2 X 0,5 kg/km 46.0 20 11344 2 X0,75 kg/km 60.0 18
11658 3 GO,S 56,0 20 11680 3 G0,75 68,0 18
11343 3 X 0,5 5.7 35.0 56,0 20 1 1 3 45 3 X 0,75 6,1 40.0 68,0 18
11659 20 11681 18
11660 4 G0.5 5 ,9 42,0 62,0 20 1 1 3 46 4 G 0.75 6,3 52.0 78,0 18
11663 4x O.S 6 2 ,0 20 11682 4 X0. 75 78,0 18
1166 5 5,9 42.0 75,0 20 11347 5 G 0,75 6,3 52.0 95,0 18
11667 5 G0.5 20 11685 18
7 G 0.5 6.4 47.0 98.0 11687 5 X 0 .75 6,8 60.0 9 5.0 18
12 G 0.5 158,0 11689 7 G 0,75 130.0 18
1 8 G 0 ,5 6,4 47,0 21 6,0 7 X 0 ,75 6,8 60.0 1 30.0
203,0 Continuation •
25 G0.5 6,9 56,0 315.0 12 G 0,75 7.4 71,0
18 G 0.75 290.0
7.6 69.0 25 G 0 ,75 7.4 71.0 413,0
9,7 108.0 8.2 91.0
11 ,5 1 45,0 8.2 91,0
13.6 240.0 10,5 142,0
12.7 212 .0
15,0 281,0
c HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ·SOO HMH·C flexible control cable, halogen-free. extremely fire II ~
ME01
resistant, oil resistant11, cu-screened, EMC-preferred type
Part no. No.cores x Outer" cop. Weight AWC·No. Part no. No.cores x Outer" Cop. Weight AWC·No.
cross-sec. approx. mm weight appro.x. mm weight approx.
11700 approx. 11794 kg/ km 6
11 701 kg/km 11812 kg/ km 6
11348 kg / km 11795 1293.0 4
11702 6.4 50.0 66,0 11796 23,4 895.0 2149,0 4
11349 6,7 60.0 11797 25,6 1282,0 4
11703 6,7 60.0 80.0 11798 1432.0
11704 7,2 71.0 80.0 11799 23.0 1070,0 1911,0 2/0
11707 100.0 11800 25,7 1140,0 2414,0 210
11709 7,2 71.0 100.0 11801 210
11711 8,0 88.0 130,0 11802 28,5 1380.0 1914,0 310
11722 8,7 111.0 160,0 11803 26.4 1240,0 2542,0 310
11723 260,0 11804 29,2 1576,0 3180,0 310
11350 11,4 184.0 382,0 11805 32,5 1930,0 4/0
11724 540,0 11806 3080.0 4/0
11725 13,5 260.0 88,0 11807 31,7 1675,0 3550,0 350kcm ~
11726 16,2 349.0 11808 35,0 2155,0 4753.0
11729 100,0 11809 39,1 2794.0 3840,0
11731 7,0 63,0 100,0 11810 37,3 2288.0 4939,0
11733 11811 41,1 3120,0 6572,0
11744 7.4 80,0 125.0 11813 46,1 3705.0
11745 158,0 42,2 3010,0 5651;0
11746 7.4 80.0 46,9 4043,0 6690,0
11747 8,1 97.0 210.0 51,8 5026.0 8370,0
11748 9,0 119.0 340,0 47,3 3812,0
11751 52,5 50i;9,0 6342,0
11766 9,8 147.0 480,0 65,5 8040.0 8453,0
11768 12.8 267,0 702.0 10800,0
11769 15,5 374.0 132,0
11770 18,5 526,0 168,0
11771 195,0
11781 8,4 96.0 222,0
11782 8,8 144,0 345,0
11783
11784 9,8 148,0 572.0
11785
11786 10,8 181,0 184.0
11787 238.0
11788 11,9 255.0 305.0
11789 15,8 441,0 388,0
11790 504,0
11793 9.9 120.0 270,0
10.4 174,0
328.0
11,6 230.0 416,0
12.9 273.0 510,0
670,0
14,2 316.0
420.0
11,7 173,0 495,0
785,0
12.5 240,0
13,8 305.0 855.0
15,3 439.0 1308,0
16.9 505,0
882 ,0
14,5 255,0
15,5 350,0
17,1 535.0
19,1 592.0
21.2 810,0
20,8 740.0
Dimensions and specifications may be changed without p rior notice. (RA03l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
MECAF LEX® SOO•C halogen-free. flame retardant. oil-resistant,
uv-resistant. flexible, screened, EMC-preferred types, meter marking
I
-· ·--
c--..! I
IRoHS I
Technical data Cable structure Properties
• Halogen-free flexible control cable. • Bare copper. fine wire conductors. to • Halogen-free
core-structure adapted to DIN VDE 0281 DIN VDE 0295 cl. 5, BS 6360 cl. 5 and
part 14, to UL-Style 20939, UL-Std. 758 IEC 60228 cl. 5 • Highly f lame-retardant
• Temperature range • core insulation of halogen-free special • Resistant to oils and greases
f lexing -30 octo +80 oc polymer
fixed installation -40 oc to +80 oc • Resistant to uv and weathering
• Black cores with white continuous
• Nominal voltage Uo/U 300/500 V numbering to DIN VDE 0293 • Flexible. abrasion- and wear-resistant
• Test voltage 3000 v • Green-yellow earth core in the outer layer • Ozone-resistant
• Minimum bending radius <3 cores and above> • Recycleable
f lexing approx. 10x cable 0 • cores stranded in layer with optimal Tests
f ixed installation approx. 4x cable 0 • Flame test to VDE 0482-332-3 I BS 4066
lay-length
• Flexible • Separating foil part 3/
Alternate bending test according to DIN DIN EN 60332-3/IEC 60332-3 Cpreviously
VDE 0281-2 • Tinned copper braided screening, coverage DIN VDE 0472 part 804 test method Cl
approx. 85% • Self-ext inguishing and flame retardant
• coupling resistance according to DIN VDE 0482-332-1-2, DIN
max. 250 Ohm/km • Outer sheath, halogen-free special polymer EN/IEC 60332-1 Cpreviously DIN VDE 0472
part 804 test method Bl
Approved to UL/CSA • Outer jacket colour grey <RAL 7001> • Corrosiveness of combustion gases
see section N , page N 56 • with meter marking, change-over in 2011 according to NF X 10-702
Halogen-free according to DIN VDE 0482
• The materials used in manufacture are part 267/ EN 50267-2-1/IEC 60754-1
cadmium -free and contain no silicone and cequivalent DIN VDE 0472 part 815)
are free from substances harmful to the • smoke density according to DIN VDE 0482
wetting properties of lacquers part 1034-1+2, DIN EN 61034·1+2/
IEC 61034·1 +2. BS 7622 part 1+2 <previously
• LSOH = Low Smoke Zero Halogen-free. DIN VDE 0472 part 816)
• Oil-resistant to DIN 60811 -2-1
• Hydrolysis-resistant to DIN EN 61234-1
• Ozone-resistant to DIN EN 60811 -2-1/
DIN VDE 0281-2
Note
• G= with green-yellow earth core;
x = without green-yellow earth core <OZl.
• unscreened analogue type:
MECiAFLEXt> 500, see page A 64, N 54
Application
For fixed installation or flexible application, with f ree movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.An interference-free transmission of signals and pulse in assured by t he high degree of screening.
As a measuring and cont rol cable primarily in machinery and plant contruction, in building and air-conditoning systems, in warehousing and
converying systems. in ship-building and for regenerative types of energy such as in the construction of wind power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a f ire.
EMC =Electromagnetic compatibillity
CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x o u te r " cop. Weight AWC·No. Part no. No.cores x outer" Cop. w eight AWC· NO.
cross-sec. approx. cross-sec. approx.
13500 approx. mm weight kg 1 km 20 13508 mm• approx. mm weight kO / km 20
13501 mm• 20 13509 20
13502 2 x0,5 kg / km 46,0 20 13510 8G0.5 kg / km 116.0 20
13504 56.0 20 13511 10 G0,5 135.0 20
13503 3G0,5 5,7 35,0 56,0 20 13512 12 G 0 ,5 8,5 80,0 158,0 20
13505 3 X0,5 62,0 20 13514 210,0 20
13506 6,0 42.0 62,0 20 13515 16 G0,5 9.3 94.0 20
13507 4 X0,5 20 18 G0,5 216,0
4 G0,5 6,0 42,0 75,0 9,6 108,0 240,0
75,0 20C 0,5 315,0
5 G0.5 6,5 47,0 25 G 0,5 10,7 129,0
5 x 0, 5 98.0
7 C0,5 6,5 47,0 11,2 145,0
7,0 56,0 11.9 172,0
7,0 56,0 13.4 240,0
7 ,9 69.0
continuation •
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
MECAFLEX® 500-C halogen-free, flame retardant, oil-resistant,
uv-resistant, flexible, screened, EMC-preferred types, meter marking
Part no. No.cor es x outer e Cop. We i gh t AWC·NO. Part no. No.cores x
approx. cross-sec.
13516 approx. mm weight kg 1 km 18
13517 18
13518 kg 1 km 60.0 18
13519 68.0 18
13520 6.1 40.0 68.0 18
13521 78,0 18
13522 6.4 52,0 78,0 18
13523 95,0 18
13524 6.4 52,0 95,0 18
13525 18
13526 6.9 60,0 130.0 18
13527 130,0 18
13528 6,9 60.0 18
13529 7,4 71,0 145.0 18
13530 180.0 18
13531 7.4 71 ,0 203.0 18
13532 275,0 17
13533 8,6 91,0 290,0 17
13534 320,0 17
13535 8.6 91,0 413.0 17
13536 17
13537 9.4 110,0 66,0 17
13538 80,0 17
13539 10,2 137,0 80,0 17
13540 17
13541 10.4 142,0 100,0 17
13542 100,0 17
13543 11,6 200.0 17
13544 130.0 17
13545 12,4 212,0 160,0 17
13546 16
13547 12,9 238,0 197,0 16
13548 232,0 16
13549 14.8 281,0 16
13550 260,0 16
13552 6,4 50,0 346,0 16
13554 382,0 16
13556 6,7 60,0 440,0 16
13557 540,0 16
13558 6,7 60,0 16
13559 88.0 16
13560 7,3 71,0 100,0 16
13561 16
7,3 71.0 100.0
125,0
7,8 88,0 158,0
210,0
9,1 111,0
244.0
9.9 127,0 315,0
10,8 150,0 340.0
424,0
11,2 184.0
480.0
12,3 209,0 545,0
702,0
13,2 260,0
13.8 317.0
15,8 349,0
6.6 63,0
6,9 80,0
6,9 80,0
7,5 97,0
8.4 119.0
10,0 147,0
10,7 170,0
11,8 193,0
12,1 267,0
13,6 315,0
14,6 374,0
15,3 396,0
17,9 526,0
Dimensions and specifications may be changed without prior notice. (RA03l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols .com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-600 H M H •C flexible control cable, halogen-free, extremely fire resistant. ~
oil resistant1' . 0,6/1kV. screened, EMC-preferred type, meter marking ME01
.~ .
HELUKABEL JZ-600 HMH-C 4G 4 QMM /12886 0.6/1kV halogen-free 001047007 CE
{BQ:HS]
Technical data Cable structure Properties
• Halogen-free, f lexible control cable, core • Bare copper, f ine w ire conductor to • 1 ) For critical applications recommend you
construction adapted to DIN VDE 0281 DIN VDE 0295 cl. 5, BS 6360 cl. 5 and/or request a consultation
Part 14 and DIN VDE0281 Part 13 IEC 60228 cl. 5
Tests
• Temperature range • Halogen-free polymer core insulation, Tl6 • Flame test ace. to VDE 0482-332-3 BS 4066
f lexing -15 octo +70 oc ace. toE DIN VDE 0281 Part 14
fixed -40 oc to +70 oc Part 3/
• Black cores with continuous white DIN EN EN 60332-3/IEC 60332-3 <as per
• Nominal voltage Uo/U 0,6/1 kV numbering according to DIN VDE 0293 DIN VDE 0472 Part 804 Test Method Cl
• Self-extinguishing and f lame-resistant ace.
• Test voltage 4000 V • Green-yellow earth core in t he outer layer to DIN VDE 0482 Part 265-2-1/
• Minimum bending radius <3 cores and above> EN 50265-2-1/ IEC 60332-1 <as per
DIN VDE 0472 Part 804 Test Method Bl
for permanent bending • Cores stranded in layers with optimal • Corrosiveness of corrosive gases ace. to
approx. 15x cable 0 lay-length VDE 0482, Part 267/ DIN EN 50267-2-2/
IEC 607542 <as per DIN VDE 0472, Part 813)
• Coupling resistance • Inner sheath • Halogen-free ace. to VDE 0482, Part 2671
max. 250 Ohm/km • Tinned copper braided screening, coverage DIN EN 50267-2-1/ IEC 60754-1 <as per
DIN VDE 0472, Part 815)
• Radiation resistance approx. 85% • smoke density according to VDE 0482
up to 100x106cJ/kg <up to 100 Mradl • Free-free polymer sheath, TM7 ace. to part 1034-1 +2 I IEC 61034-1 +2 I
DIN EN 61034-1+2 I BS 7622 part 1+2
E DIN VDE0281 Part 14 <equivalent DIN VDE0472 part 8161
• Sheath colour black <RAL 9005l Note
• w ith meter marking, change-over in 2011
• unscreened analogue type:
• The materials used in manufacture are JZ-600 HMH, see page A 66
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Application
Halogen-free. f lame retardant cables are used as measuring and control cable in machine tools, conveyor belts. production lines as well as
in plant installations. in heating and air-conditioning systems and steel production works. For fixed installation or flexible application. directed
without forcing by casual, constantly recurring free movements and without tensile stress. for medium mechanical strain. This cable is
suitable for the application in dry, damp and wet environments and outdoors (fixed installation! and for laying on. in and under plaster as
well as in concrete and masonry excluding in direct laying in vibration. compacted or compressed concrete. The dense screening assures
interference-free transmission of all signals and impulses.
EMC = Electromagnetic compatibillitv
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
C€= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x outer e Cop. Weight AWC·No. Part no. No.cores x out er 0 Cop. Weight AWC·No.
cross-sec. approx. approx. mm w eight approx. Continuation •
12850 mm• approx. mm w ei g ht kg / km 20 12864 kg / km
12851 20 12865 kg/ km
12852 3 G0,5 kg/ km 150,0 20 12866 163,0
12853 4G0,5 170,0 20 12867 9,8 64,0 200,0
12854 8 ,8 45,0 20 12868 10,6 76,0
12855 5G0.5 199.0 20 12869 11,4 89.0 239.0
12856 7 G0.5 9,6 54,0 235,0 20 12870 12,5 114,0 289,0
12857 12 G0,5 320,0 18 12871 15,7 186.0 464,0
12858 18 G0,5 10,2 66,0 428,0 18 12872 18.4 284,0
12859 25 G 0 ,5 18 12873 21,6 387,0 628.0
12860 11 ,1 79,0 503.0 18 12874 855,0
12861 3 G0.75 155.0 18 12875 11.1 82,0
12862 4 G0,75 14,0 137,0 190,0 18 12876 11,8 99,0 187,0
12863 18 12877 240,0
5 G0,75 16,2 156,0 228,0 13,1 123.0
7 G0,75 323.0 14.2 148.0 289.0
12 G0,75 19,1 250,0 410.0 18,1 274,0 383.0
18 G0,75 560,0 21 .4 386,0 592 ,0
25 G0.75 9,3 57.0 730,0 24,9 531 ,0 806,0
9,9 63,0 1241,0
10.8 76,0
11 .5 100,0
14,8 175,0
17.1 240,0
20,2 306,0
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols .com
Click or Call for a Quotel
~ CONTROLS, INC.
JZ-600 HMH·C flexible control cable, halogen-free, extremely fire resistant, ~
MEOI
oil resistant11, 0,6/1kV, screened, EMC-preferred type, meter marking
Part no. No.cores x Outer 0 Cop. Weight AWC-No. Part no. No.cores x Outer 0 cop. Weight AWC-No.
approx. mm weight approx. cross-sec. approx. mm weight approx.
12878 kg/km kg 1 km
12879 kg 1 km kg/ km
12880 298.0 1395.0
12881 148.0 345,0 26.1 807.0 1870,0
12882 169,0 427,0 29.0 940,0 2720,0
12883 561,0 31.8 1345.0
12884 220.0 857,0 28,7 920,0 2465,0
12885 284.0 1355,0 2750.0
12886 470,0 1995,0 31.7 1169.0 3490,0
12887 35,0 1420.0 3230,0
12888 572.0 391,0
12889 740,0 527,0 31 .2 1250.0 4100.0
12890 178,0 34.5 1680,0 4950,0
12891 234,0 700,0 38,1 2020.0
12892 629,0 40,7 2370,0 5780,0
12893 284,0 731,0
245,0 1105,0 46.0 3257.0 7480.0
316,0 51,3 4060,0 10220,0
442,0 1125,0 56,4 5231.0
1345,0 13750,0
367.0 1635,0 64.3 6794.0 15900,0
549,0
604.0
Dimensions and specifications may be changed without prior notice. !RA03l
Bundling, binding, fastening
Plastic helix
Cable tie
Hook and loop cable tie
Mounting block
You can find bundling, binding, fastening in our catalog Cable Accessories.
Request it now at www.hitechcontrols.com
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JB-750 HMH·C flexible control cable, coloured core. halogen-free, II ~
MEOI
screened, extremely fire resistant. oil resistant11, EMC-preferred type, meter marking
RoH~
Technical data cable structure Properties
• Halogen-free core flexible control cable, • Bare copper, fine wire conductors, to • 1) For the critical applications we advise for
adapted toE DIN VDE 0281 part 14 and DIN VDE 0295 cl. 5, BS 6360 cl. 5 and consu lt a t i o n
DIN VDE 0281 part 13
IEC 60228 cl. 5 • The materials used in manufacture are
• Temperature range • Core insulation of halogen-free compound cadmium-free and contain no silicone and
f lexing -15 octo +70 •c free from substances harmful to the
f ixed installation -40 oc to +70 oc Tl6, toE DIN VDE 0281 part 14 wetting properties of lacquers
• Colour coded to DIN VDE 0293-308
• Nominal voltage UoiU 450/750 V Tests
• Green-yellow earth core in the outer layer • Flame test to DIN VDE 0482-332 -3 BS 4066
• Test voltage 3000 v
• Cores laid up in layers w ith optimal part 31 DIN EN 60332-311EC 60332-3
• Minimum bending radius lay-length <equivalent DIN VDE 0472 part 804 test
f lexing approx. 12,5x cable 0
f ixed installation approx. 4x cable 0 • Separating layer method C>
• Screen braid of tinned copper wires, • Self-extinguishing and flame retardant
• coupling resistance
max. 250 Ohmlkm coverage approx. 85% according to DIN VDE 0482 part 265-2-11
• Halogen-free sheath compound TM7, to EN 50265-2-11 IEC 60332-1 <equivalent
• Radiation resistance DIN VDE 0472 part 804 test method B>
up to 100x106 cJikg <up to 100 Mrad> E DIN VDE 0281 part 14 • Corrosiveness of combustion gases
• Jacket colour grey <RAL 7001) according to DIN VDE 0482 part 2671
EN 50267-2-21 IEC 60754-2 <equivalent
• with meter marking, change-over in 2011 DIN VDE 0472 part 813)
• Halogen-free according to DIN VDE 0482
• LSOH = Low smoke zero Halogen-free. part 267I EN 50267-2-11 IEC 60754-1
<equivalent DIN VDE 0472 part 815)
• Smoke density according to VDE 0482
part 1034-1+2 I IEC 61034-1+2 I
DIN EN 61034-1+2 I BS 7622 part 1+2
(equivalent DIN VDE 0472 part 816>
Note
• G =with green-yellow earth core
• Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
• unscreened analogue type:
JB-750 HMH, see page A 68
Application
Halogen -free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation
belts. production lines. in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for f lexing
applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical
loads. The cable is suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry
and concrete walls except for direct embedding in vibrated, compacted or tamped concrete, not suitable for imbedding in solidified or
compressed concrete.
An interference-free transmission of signals and pulse in assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
CE= The product is conformed with the EC Low-Voltage Directive 20061951EG.
Part no. No.cores x Outer e Cop. Weight AWG-No. Part no. No.cores x Outer e Cop. Weight AWG·No.
approx. a pprox.
11942 approx. mm weig ht kg 1 km 16 11948 approx. mm weight kg lkm
11943 16 11949
11944 kglkm 12S.O 16 11950 kg I km 251,0
11945 160,0 14 11951 315,0
11946 7,4 80,0 193,0 14 11952 10.4 174,0 396,0
11947 14 11,6 230,0
8,1 97,0 198,0 12.9 273,0 430,0
240.0 13,8 305,0 524,0
9,0 119,0 15.3 439,0
280.0
8.8 144,0
9.8 148.0
10.8 181.0
continuation •
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
JB-750 HMH-C flexible control cable. coloured core. halogen-free.
screened. extremely fire resistant. oil resistant11, EMC-preferred type, meter marking
Part no. No.cores x outer 0 Cop. weight AWC·NO. Part no. No.cores x
cross-sec. approx.mm weight approx. cross-sec.
11953 kg I km kg/km
11954
11955 17,1 535.0 804,0
11956 942,0
11957 19,1 592,0
11958 1190,0
20,8 740,0
1370,0
23.4 895.0 1968,0
2514,0
25,7 1140,0
28.5 1380,0
Dimensions and specifications may be changed without prior notice. <RA03>
Marking
Marking rings
Cable marker
Indian pen
You can find marking in our catalog Cable Accessories.
Request it now at www.hitechcontrols.com
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
OZ-BL
OZ-BL·CY
08-BL-PAAR-CY
Photo: 0 iStockphoto.com/Michael Utech
PVC control Cables for Intrinsically Safe Circuits
Electrical cables for intrinsically safe circuits The installation of these cables outside of intrinsi-
(separate power circuit of hazard type-i-) have cally safe circuits is not permitted. The installation
to be specially marked with a blue outer sheath can be done in dry and damp environments, but
(RAL 5015) according to DIN VDE. HELUKABEL® not in underground and in open air. The special
manufactures these cables according to DIN VDE
0165 and in addition, screened types according PVC outer sheath material is resistant to oil and
to DIN VDE 0165, part 1, EN 60079-14 and IEC petrol as well as being flame resistant.
HELUKABEL®can deliver almost all the cables as
60079-14 section 12.2.2.6. per typelists on the following pages, predomi-
As these cables are installed with separate power
circuit, the application of green-yellow protective nantly available in stock. Special cables can be
conductor is not allowed. manufactured in a short time.
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
OZ·BL outer jacket blue, intrinsic safety, flexible, meter marking
Technical data Cable structure Properties
• Control cable. special PVC with blue outer • Bare copper. fine wire conductors. bunch • Extensively oil resistant. oil-/ chemical
jacket for hazardous areas to hazard type stranded to DIN VDE 0295 cl. 5, BS 6360 Resistance - see table Technical
cl. 5 and IEC 60228 cl. 5 Inf o rm a tions.
+ <=intrinsically safel
• Core insulation of special PVC Z 7225 • PVC self-extinguishing and flame retardant
• For intrinsically safe installation according according to VDE 0482-332-1-2, DIN EN
to DIN EN 60079-14 and IEC 60079-1 4 • Black cores with white continuous f igure 60332-1-2/ IEC 60332-1 <equivalent
section 12.2.2 <VDE 0165 part 1l imprint to DIN VDE 0293 without earth core DIN VDE 0472 part 804 test method Bl
• Temperature range • cores stranded in layers with optimal • The materials used in manufacture are
lay-le n g th cadmium -free and contain no silicone and
f lexing -15 •c, to +80 •c f ree f rom substances harmful to the
f ixed installation -40 •c to +80 •c • Special PVC outer sheath TM2, to wetting properties of lacquers
• Nominal voltage Uo/U 300/500 v DIN VDE 0281 part 1 and HD 21 .1
Note
• Test voltage 3000 V • Colour blue <RAL 5015l
• For underground laying use NYY with blue
• Breakdown voltage min. 6000 v • with meter marking, change-over in 2011 outer sheath.
• Insulation resistance • AWG sizes are approximate equivalent
m in . 20 MOhm x km values. The actual cross-section is in mm2.
• Mutual capacitance • Instrumentation cable RE-2Y<StlYv with blue
core/core approx. 120 nF/km outer jacket see catalog part B.
• Inductance approx. 0.68 mH/km
• Minimum bending radius
flexing 7,5x cable 0
fixed installation 4x cable 0
• Radiation resistance
up to 80x106 cJ/kg Cup to 80 Mradl
• 1 ' cold bending test. impact resistance test
at low temperatures. elongation test at low
temperatures. Tested according VDE 0473
Teil81 1-1-4, EN 60811-1-4
Application
For hazardous areas the cables with special marking <bluel (hazard type-i-l used as flexible control and measuring cables to meet t he
requirements for t he installation of electrical apparatus. These installations are not earthed and require a separate power circuit . Those cables
are not suitable for underground laying .
CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outer " cop. Weight AWC-No. Part no. No.cores x Outer" cop. Weight AWC-No.
cross-sec. approx. cross-sec. approx.
14001 mm• approx. mm weight kg 1 km 18 14019 approx. mm w eight kg / km
14002 18 14020 kg / km
14003 2 X0,75 kg / km 46,0 18 14021 70,0
14004 3 X0,75 54,0 18
14075 4 X0,75 5.3 14,4 66,0 18 ~4022 6.4 29.0 90.0
14005 5 x0,75 80,0 18 6.8 43.0 109.0
14076 7 X0,75 5.6 21,6 110,0 18 14023 7,4 58.0 131,0
14006 8 X0,75 130,0 18 14024 8,3 72.0 184,0
14007 12 X0,75 6.3 29.0 179,0 18 14025 309,0
14008 18 x0.75 18 14026 440,0
14009 25 X0,75 6,9 36,0 257.0 18 14027 620,0
14010 30 X 0,75 365,0 18 14100 842,0
14011 34 X0,75 7,5 52,0 448,0 17 14101 9.2 101,0 148,0
14012 41 X 0,75 510,0 17 12,0 173,0 178,0
14013 8.2 58,0 607,0 17 ~4102 221 ,0
14014 2 X1 17
14015 3x1 9.8 88,0 60,0 17 14,6 259,0
14016 4X1 17
14017 Sx1 12,2 130.0 72.0 17 17,4 360.0
14018 7 X1 86.0 17 18.6 440,0
12 X1 14.3 180.0 104.0
18 X1 141,0
25 X1 15,3 215.0 230,0 8.3 72.0
343,0 9.2 96,0
16,7 245,0 485,0
18,0 298,0 10,1 120.0
5,6 19,0
5,9 29,0
6,6 38,0
7,3 48,0
8,1 67 ,0
10.4 115.0
12,9 173,0
15,4 240,0
Dimensions and specifications may be changed without prior notice. <RA04>
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
OZ·BL·CY outer jacket blue, intrinsic safety, flexible, meter marking
RoH~
Technical data Cable structure Properties
• Cont rol cable, special PVC with blue outer • Bare copper, fine w ire conductors. bunch • Extensively oil resistant. oil-/ chemical
jacket for hazardous areas to hazard type stranded to DIN VDE0295 cl. 5, BS 6360 Resistance- see table Technical
cl. 5 and IEC 60228 cl. 5 Inf o r m a t i o ns.
+ <=intrinsically safe>
• Core insulation of special PVC z 7225 • PVC self-extinguishing and f lame retardant
• For intrinsically saf e installation according according to VDE 0482-332-1-2, DIN EN
to DIN EN 60079-14 and IEC 60079-1 4 • Black cores with white continuous f igure 60332-1-2/ IEC 60332-1 <equivalent
section 12.2.2. <VDE 0165 part 1> imprint to DIN VDE0293 without earth core DIN VDE0472 part 804 test method Bl
• Temperature range • Cores stranded in layers with optimal • The materials used in manufacture are
lay-length cadmium -free and contain no silicone and
flexing -5 oc to +80 oc free f rom substances harmful to the
f ixed installation -40 oc to +80 oc • Core wrapping of plastic f oil wetting properties of lacquers
• Nominal voltage Uo/U 300/500 V • Braiding, t inned copper wire screening, Note
approx. 85% coverage
• Test voltage 3000 v • For underground laying use NYY with blue
• Breakdown voltage m in. 6000 v • Special PVC outer sheath TM2. to outer sheath.
DIN VDE 0281 part 1 and HD 21.1
• Insulation resistance • AWG sizes are approximate equivalent
m in. 20 MOhm x km • Colour blue <RAL 50151 values. The actual cross-section is in mm2 .
• with meter m arking, change-over in 2011
• Mutual capacitance • Instrumentation cable RE-2Y<St>Yv with blue
core/ core approx. 140 nF/km outer jacket see catalog part B.
core/screen approx. 187 nF/km
• Inductance approx. 0,68 m H/km
• coupling resistance
max. 250 Ohm/km
• Minimum bending radius
f lexing 10x cable 0
fixed installation 5x cable 0
• Radiation resistance
up to 80x10GcJ/kg <up to 80 Mradl
Application
For hazardous areas t he cables with special m arking <blue><hazard type-i-l used as flexible control and measuring cables to meet t he
requirem ents for t he installation of elect rical apparatus. These installations are not earthed and require a separate power circuit. Those cables
are not suitable for underground laying.
=The copper braided screening ensures t he t ransm ission of data signals and free from interference.
EMC Electromagnetic compat ibillity
To optim ise the EMC features we recommend a large ro und contact of t he copper braiding on both ends.
CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EG .
Part no. No.cores x outer" cop. weight AWC·No. Part no. No.cores x outer" cop. We i gh t AWC·NO.
cross-sec. approx. mm weight approx. cross-sec. approx.
14028 mm• kg / k.m 14050 mm• approx. mm w eight kg / km 16
14029 14051 16
14030 2 X 0 ,75 kg / km 59,0 14052 2 X 1,5 kg / km 88.0 16
14031 3 X 0 ,75 66,0 14053 3 X1 ,5 100.0 16
14088 4 X 0 ,75 6,1 40.0 77,0 1 4 05 4 4 X 1,5 7,0 63.0 126.0 16
14032 14055 160.0 16
14033 5 X 0 ,75 6 ,3 52 ,0 93,0 14056 5 X 1,5 7,5 80,0 208,0 16
14034 7 X 0,75 130,0 14057 7 X 1,5 16
14035 8 X 0,75 6.8 60.0 145,0 14058 12 X1,5 8 .1 97,0 3 38,0 16
14036 10 X 0 ,75 180,0 14059 479.0 16
14037 12 x0,75 7.4 71,0 202 ,0 18 X 1,5 9 ,0 119,0 705,0
14038 18 X 0,75 292.0 25 X 1,5 830,0
14039 8.2 9 1,0 362,0 30 X 1,5 9,8 147,0 900,0
14040 2d X 0,75 415,0 34 X1,5
1404 1 25 X 0,75 9.6 110.0 486,0 12,8 267,0
14042 30 x0,75 523.0
1 40 4 3 34 X 0,75 10.3 137.0 680,0 15.4 374,0
14044 41 X0,75
14045 10.5 142.0 65,0 18.4 526,0
14046 2 X1 81 ,0
14047 3x1 12 ,7 212 ,0 98,0 19 .1 555,0
14048 4 X1
1 40 4 9 5x1 13,3 238,0 127.0 20.8 629,0
7x1 158.0
12 X1 15,0 281 ,0 260,0
18 X 1 15,8 320,0 380.0
25 X1 534,0
34 X1 17,2 345,0
741.0
18.6 400,0
6.4 50.0
6,7 60,0
7.2 71 .0
8 ,0 88,0
8.7 111.0
11.4 184,0
13.5 260,0
16.2 349,0
18,5 486.0
Dimensions and specificat ions may be changed without prior not ice . <RA04l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
0 B•BL• PAA R•CY c.outer jacket blue, intrinsic safety. EMC·preferred type, meter
marking MEOI
RoHS
Technical data Cable structure Properties
• Special PVC control cable with blue outer • Bare copper. fine wire conductors. bunch • Extensively oil resistant. oil-/ chemical
jacket for hazardous areas to hazard type stranded to DIN VDE 0295 cl 5, BS 6360 Resistance - see table Technical
-i- for intrinsically safe installation according cl. 5 and IEC 60228 cl. 5 Informations
to DIN EN 60079-14 and IEC 60079-14
section 12.2.2. <VDE 0165 part 1l • Special PVC core insulation Yl2, to • PVC self-extinguishing and flame retardant
DIN VDE 0207 part 4 according to VDE 0482-332-1-2, DIN EN
• conductor resistance 60332-1-2/IEC 60332-1 <equivalent
at 0,5 mm2 s37.8 Ohm/km • Cores colour coded according to DIN 47100 DIN VDE 0472 part 804 test method Bl
at 0.75 mm2 :>25,3 Ohm/km • cores twisted in pairs • The materials used in manufacture are
• Temperature range cadmium-free and contain no silicone and
• Pairs stranded in layers with optimal free from substances harmful to the
flexing -5 oc to +80 oc lay-length wetting properties of lacquers
fixed installation -30 oc to +80 oc
• Foil taped Note
• Nominal voltage 900 V • Tinned copper braided screening, approx.
<not for power installation> • AWG sizes are approximate equivalent
80% coverage values. The actual cross-section is in mm2.
• Test voltage
• Special PVC outer sheath YM2. to • Instrumentation cable RE-2YCSt>Yv with blue
core/core 2000 v DIN VDE 0207 part 5 outer jacket see catalog part B.
core/screen 1000 v
• Breakdown voltage m in . 4000 v • Colour blue RAL 5015
• with meter marking, change-over in 2011
• Insulation resistance
min. 20 MOhm x km
• Mutual capacitance
core/core approx. 105 nF/km
core/screen approx. 145 nF/km
• Inductance
approx. 0.68 mH/km
• Characteristic impedance
approx. 80 Ohm
• Minimum bending radius
flexing 10x cable 0
fixed installation 5x cable 0
• Radiation re sistance
up to 80x106cJ/kg Cup to 80 Mradl
• Coupling resistance
max. 250 Ohm/km
Application
For hazardous areas this f lexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part
12.2.2.6. which covers the requirements for the special marking Cbluel of this type <hazard type -i-l.
The paired construction and the copper screening afford a good protection against electrical interference and ensure the transmission of
data signals.
EMC =Electromagnetic compatibillitv
To optim ise the EMC features we recommend a large round contact of the copper braiding on both ends.
C€= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.palrs x outer 0 Cop. Weight AWC·NO. Part no. No.palrs x outer 0 Cop. Weight AWC·NO.
cross-sec. approx. weight cross-sec. approx. weight approx.
14077 mm• mm kg/ km approx. 20 14089 mm• mm kg / km kg 1 km 18
14078 kg / km 20 14090 18
14079 2 X 2 X 0,5 7,8 47,0 20 14091 2x2x0,75 8,4 60.0 105,0 18
14080 3 X2 X 0,5 8,2 67,0 89,0 20 14092 3 X2 X0.75 9,0 80,0 128,0 18
14081 4 X 2 X 0,5 80,0 104,0 20 14093 4x2x0,75 9,8 110,0 156,0 18
14082 6 X2)( 0,5 9.0 108,0 126,0 20 14094 6 X2 X0,75 12,1 142,0 216,0 18
14083 8 X2 X0,5 10,6 129,0 171,0 20 14095 8x2x0,75 13,4 200,0 309,0 18
14084 10 X2 X0,5 12,3 172,0 251,0 20 14096 10x2x0,75 15,1 238,0 18
14085 12x2x0,5 13.5 235,0 282,0 20 14097 12 X2 X0,75 15,8 270,0 355.0 18
14086 16 X2 X0.5 14.4 301,0 261,0 20 14098 16x2x0,75 18,0 342,0 405,0 18
14087 20 X 2 X 0,5 16.3 343,0 445,0 20 14099 20x2x0,75 19,2 369.0 560,0 18
24 X2 X0,5 17,7 394,0 525,0 24x2x0.75 21,3 451,0 671.0
25 X2 X 0,5 406,0 25x2x0,75 21,8 461,0 795,0
19,3 590.0 803,0
19,7 622.0
Dimensions and specifications may be changed w ithout p rior notice. !RA04l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
BIOFlE ·50 ®.J
BIOF.LEX·SOO®·JZ-C
KOMPOFLEX® JZ-5 0
KOMPOFLEX® JZ-500-
Photo: FUCHS OEA SCHMIERSTOFFE GMBH & Co. KG
Bio-Oil and microbial resistant Cables
We have joined forces with large scale farmers wires from HELUKABEL®. Specially modified po-
and operators of biofuel plants to develop a lymers are used here for the core insulation and
tailor-made product - the new BIOFLEX-500®. the jacket materials.
HELUKABEL®has accordingly matched and ex- In the laboratory, these special compounds have
tended the range of products from its plant in been subjected to extreme testing according to
VDMA requirements and VDE specifications. The
Windsbach. Special control cables and wires have suitability of these compounds has been assessed
been developed which are not only friendly on by endurance testing to demonstrate the long-
the environment, abrasion-resistant and can be term resistance to bio -oils.
recycled, they are also resistant to bio-oils. These
are the special BIOFLEX-SQQ®-control cables and
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
BIOFLEX·SOO®·JZ Bio-fuel resistant, abrasion resistant, recyclable environment
friendly, bio-oil resistant11, meter marking
[RoHS I
Technical data Cable structure Properties
• Bio-oil resistant. abrasion resistant special • Bare copper. fine wire conductors, bunch • Resistant to
control cable in adapted to DIN VDE 0281 stranded to DIN VDE 0295 cl. 5, BS 6360 Bio-fuel !diesel and petroll, highly resistant
cl. 5 and IEC 60228 cl. 5 to biologically decomposable oils, Oxygene,
• Temperature range Ozone, Hydrolysis and Microbes
flexing -20 •c to +80 •c • Special polymer core insulation
fixed installation -40 •c to +80 •c • Low adhesion
• Black cores with continuous white figure
• Nominal voltage Uo/U 300/500 v imprint to DIN VDE 0293 Note
• Test voltage 3000 v
• Green-yellow earth core in t he outer layer • G = with green-yellow earth core;
• Insulation resistance <3 cores and above> x =without green-yellow earth core !OZl.
min . 20 MOhm x km
• cores stranded in layers with optimal • AWG sizes are approximate equivalent
• Minimum bending radius lay- le n g t h values. The actual cross-section is in mm2.
flexing 15x cable 0
fixed installation 4x cable 0 • Special outher sheath. polymer compound • screened analogue type:
BIOFLEX·SOO®·JZ·C, see page A 85
• Radiation resistance • Colour dark green
up to 100x106 cJ/kg !up to 100 Mradl • with meter marking, change-over in 2011
Application
HELUKABEL® BIOFLEX-500-JZ is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance
to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited f or use in the machine. tool making and plant industries as well as in the
steel industry for difficult and problem areas. The high f lexibility of this cable type makes it quick and easy to install. Suitable for outdoor
lying.
1l For the critical applications we advise for consultation.
CE.:: The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outer 111 Cop. Weight AWC•NO. Part no. No.cores x outer 111 Cop. Weight AWC·NO.
cross-sec. approx. cross- sec. approx. mm w eight approx.
25620 mm• approx. mm weight kg / km 20 25654 kg / km
25621 20 256S5 kg / km
25622 2 x0.5 kg / km 45.0 20 25656 68.0
25623 3G0,5 20 25657 29.0 87,0
25624 4 G0,5 5.4 9,6 S5.0 20 25658 43.0 106,0
25625 5,9 14.4 65,0 20 25659 58.0 131,0
25626 5G0.5 6,3 19.0 20 25660 72.0 173,0
25627 7 G0,5 6,9 24,0 75.0 20 25661 101 .0 245,0
25628 7,8 33,6 90,0 20 25662 144,0 293,0
25629 10 G0.5 9,6 48,0 20 25663 173,0 347,0
25630 12 G0.5 10.0 58,0 120.0 18 25664 454,0
25631 14 G0,5 10,3 67,0 135.0 18 25665 202.0 641,0
25632 18 G0,5 11,5 86,0 18 25666 259.0 1100,0
25633 25 G0,5 13,6 120,0 170.0 18 25667 360,0
25634 5.4 14,4 205,0 18 25668 110,0
25635 2 X 0,75 6.2 21,6 18 25669 605.0 146,0
25636 3 G0.75 6,7 29.0 270.0 18 25670 48.0 183,0
25637 4 G0,75 7,3 36,0 44,0 18 25671 72,0 222,0
25638 5 G0,75 8.8 50,0 53,0 18 25672 96.0 293.0
25639 7 G0,75 10,5 72,0 64,0 18 25673 512,0
25640 11.0 86,0 76,0 18 25674 120,0 740,0
25641 10 G0,75 11.4 101.0 96,0 18 25675 168.0 940,0
25642 12 G0.75 12,6 130,0 140.0 17 25676 288,0 147,0
25643 14 G0.75 15.2 180.0 170,0 17 25677 432.0
25644 18 G0.75 18,0 296,0 202,0 17 25678 600.0 228.0
25645 25 G0,75 18,5 310,0 260.0 17 25679 291,0
25646 41 G0,75 6.6 19,0 282,0 17 25680 77.0 355,0
25647 42 G0,75 7.0 29.0 600,0 17 25681 115.0
25648 7.6 38.0 620.0 17 25682 154.0 362,0
25649 2x1 8,2 48.0 17 25683 192.0 468.0
25650 3 G1 9.6 67,0 53.0 17 25684 173.0 570,0
25651 4G1 11,6 96,0 63,0 17 25685 230,0 555,0
25652 17 25686 288,0 720,0
25653 5G 1 12.0 115.0 75.0 17 25687 288,0 894,0
7G1 13.2 134,0 89,0 25688
10G 1 14.5 173,0 115,0 25689 384.0 1063,0
12 G1 17,6 240.0 166,0 25690 480,0 1400,0
14 G1 21.1 394.0 614~0
21.5 403.0 201.0 768,0 1590,0
18 G1 230.0
25 G1 289,0 960.0 2200.0
41 G1 1344.0 2400,0
380.0
42 G1 720.0 1920.0 4400,0
740.0 2688.0
6000.0
3648.0 7400,0
4608.0
Dimensions and specifications may be changed without prior notice. IRAOS>
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols .com
Click or Call for a Quotel
~ CONTROLS, INC.
BIOFLEX·SOO®·JZ·C Bio-fuel resistant, abrasion resistant, recyclable
environment friendly, bio·oil resistant11, cu-screened, EMC-preferred type, meter marking
Part no. No.cores x outer e Cop. Weight AWG·NO. Part no. No.cores x Outer 1/J Cop. AWG·No.
cross-sec. approx. cross-sec. approx. mm weight
approx. mm weight kg / km 16
kg / km 16 kg / km
1360.0 14 17.0 316.0
27,2 840,0 1375,0 14 18,6 442,0
27.5 890,0 14 19,5 367,0
10,6 110,0 180,0 14
11,1 148,0 14 21.5 549,0
12.1 169,0 215,0 14 23,9 604,0
13,2 220,0 268,0 12 24,6 807,0
15,9 284,0 349,0 12 27,3 940,0
19,5 470,0 406,0 12
12,6 124,0 720,0 12 30,6 1169,0
13,4 178.0 300,0 10
15,0 234,0 36.9 1680.0
16,4 284.0 340.0 41.3 2370,0
15,2 245,0 408.0 48.8 3257,0
504,0 61,8 4060.Q
65.7 5231,0
453,0
Dimensions and specificat ions may be changed without prior notice. !RAOSl
Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife
You can find tools in our catalog Cable Accessories
Request it now at www.hitechcontrols.com
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
KOMPOFLEX® JZ-500meter marking halogen-free. microbes resistant, low adhesion, ~
MEOI
Technical data Cable structure Properties
• Microbes resistant. halogen-free special • Tinned copper. fine wire conductors. bunch • Resistant to
control cable in adapted to DIN VDE 0281 stranded to DIN VDE 0295 cl. 5, BS 6360 UV-radiation, Oxygene. Ozone, Microbes.
part 13 cl. 5 and IEC 60228 cl. 5 Hydrofluoric acid. Hydrochloric acid and
diluted sulfuric acid
• Temperature range • Special thermoplastic polymer-core
flexing -30 octo+ 90 oc insulation • The materials used in manufacture are
fixed installation -40 octo +100 oc cadmium-free and contain no silicone and
• Black cores with continuous white free from substances harmful to t he
• Nominal voltage Uo/U 300/500 v numbering according to DIN VDE 0293 wetting properties of lacquers
• Test voltage 3000 V • Green-yellow earth core in the outer layer • Low adhesion
(3 cores and abovel
• Insulation resistance Note
min. 20 MOhm x km • Cores stranded in layers with optimal
lay-length • G = with green-yellow earth core;
• Minimum bending radius x =without green-yellow earth core (0Zl.
flexing 7.5x cable 0 • Outher sheath. special thermoplastic
fixed installation 4x cable 0 polymer • AWG sizes are approximate equivalent
values. The actual cross-section is in mm2•
• Radiation resistance • Colour black (RAL 9005)
up to 100x106 cJ/kg (up to 100 Mradl • screened analogue type:
• with meter marking, change-over in 2011 KOMPOFLEX®JZ-500-C, see page A 88
Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants. composting works. animal stalls
and greenhouses. Suitable for installation for f lexible use for medium mechanical, stresses with free movement w ithout tensile stress or
forced movements in dry, moist and wet rooms as well as outside.
CE= The product is conformed w ith the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outer 0 Cop. Weight AWO•No. Part no. No.cores x Outer 0 Cop. Weight AWC•No.
cross-sec. approx. cross-sec. approx. mm weight approx.
26125 approx. mm weight kg t km 20 26168 kg / km
26126 mm2 20 26169 kg tkm
26127 2 X0.5 kg tkm 41.0 20 26170 79.0
26128 3G0,5 20 26171 6.7 43.0 98.0
26129 4G0,5 4.8 9.6 so.o 20 26172 7.3 S8.0 112.0
26130 5G0,5 20 26173 8,2 72.0 1S9.0
26131 7 G0,5 5,1 14,4 61.0 20 26174 9,8 101.0 280.0
26132 72.0 20 26175 12.1 173.0 420,0
26133 12 G 0.5 5.7 19.0 86.0 20 26176 14.5 259,0 480,0
26155 18 G0,5 130,0 20 26177 15.2 288.0
26136 20G0,5 6.2 24.0 20 26178 17,8 360.0 604.0
26137 25 G 0,5 198.0 20 26179 19,8 490.0 812.0
26138 34 G0,5 7.4 33.6 211,0 20 26180 21.4 605.0 1002.0
26139 42 G 0,5 260,0 18 26181 23.7 720.0 1240,0
26140 9.1 58.0 361,0 18 26182 25.3 878,0 1421,0
26141 50G0.5 18 26183 7.6 48.0
26142 61 G 0,5 10,7 86.0 405.0 18 26184 8,3 72.0 99.0
26143 541.0 18 26185 9.1 96.0 136.0
26144 2 X0.7S 11.2 96.0 670.0 18 26186 10,2 120.0 170.0
26145 3 G0 ,75 42,0 18 26187 12.1 168.0 204,0
26146 4 G0.75 13,0 120.0 49.0 18 26189 15,2 288.0 281,0
26147 5 G0,75 60,0 18 26190 18.1 432.0 487,0
26149 7 G 0,75 14,5 163,0 18 26191 704.0
26150 12 G 0,75 71.0 18 26192 22.2 600.0
26151 18 G 0,75 15,8 202.0 88,0 18 26193 9,9 115.0 909.0
26152 20 G0,75 161 ,0 18 26195 224.0
26153 25 G 0,75 17,3 240.0 17 26196 11,0 154,0 289.0
26154 34 G 0,75 250.0 17 26197 12,1 192.0 357.0
26155 42 G0,75 19.4 293.0 266.0 17 26198 13,3 269.0 451.0
26156 50 G 0,75 273,0 17 26199 18.3 461.0 782.0
26157 61 G0,75 5,2 14.4 17 26200 11,7 173,0 34S,O
26158 501.0 17 26201 13.0 230,0 417,0
26159 2x1 5,5 21.6 591.0 17 26202 14,5 288.0
26160 3G1 712.0 17 26204 16,0 403,0 521.0
26162 4G1 6.2 29.0 820,0 17 26206 622,0
26163 17 26208 15.0 288,0
26164 5G1 6.8 36.0 48.0 17 26212 16.8 384.0 537,0
26165 7G1 56.0 17 26215 18,7 480.0 699.0
26166 12 G1 8,1 50.0 70.0 17 26216 20,6 672.0 851.0
26167 18 G1 81.0 16 19,7 614,0 1102 .0
20 G 1 9.9 86.0 109.0
30G 1 191.0 24.4 1075.0 1028.0
34 G1 11,9 130.0 274.0 25,2 960,0 1772.0
42 G 1 314.0 29,0 1344,0 1577,0
12.6 144.0 492.0
soc 1 640,0 33.4 1920.0 2097,0
61 c 1 14,5 180,0 37.2 2400.0
804.0 2914.0
2 X1,5 16.4 245.0 932.0 3919.0
1102.0
17,6 302,0
60.0
19,8 360.0
20,9 439,0
5,5 19.0
6,0 29.0
6,6 38.0
7,2 48.0
8,6 67,0
10.7 115.0
12.7 173,0
13,5 192.0
16.0 288.0
17,4 326.0
18.9 403,0
21.0 480.0
22.2 586.0
6,3 29,0
Dimensions and specifications may be changed without prior notice. <RAOSl
c HELUKABEL
~HI-TECH (800) 677-8942 I (303) 680-5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
KOMPOFLEX® JZ·SOO·CEMC-preferred type, meter marking halogen-free, microbes resistant, cu-screened, ~
M£01
RoHS I
Technical data Cable structure Properties
• Screened microbes resistant. halogen-free • Tinned copper, fine wire conductors, bunch • Resistant to
special control cable in adapted to stranded to DIN VDE 0295 cl. 5, BS 6360 UV-radiation, Oxygene, Ozone, Microbes,
DIN VDE 0281 part 13 cl. 5 and IEC 60228 cl. 5 Hydrofluoric acid, Hydrochloric acid and
diluted sulfuric acid
• Temperature range • Special thermoplastic polymer core
f lexing -30 oc to+ 90 oc in sulatio n • Low adhesion
fixed installation -40 octo +100 oc • The materials used in manufacture are
• Black cores w ith cont inuous white
• Nominal voltage Uo/U 300/500 v numbering according to DIN VDE 0293 cadmium -free and contain no silicone and
f ree from substances harmful to the
• Test voltage • Green-yellow earth core in the outer layer wetting properties of lacquers
core/core 4000 v <3 cores and above! Note
• Cores stranded in layers with optimal
core/screen 2000 V • G =with green-yellow earth core;
• Insulation resistance lay-length x = without green-yellow earth core <OZl.
• Inner-sheath to special thermoplastic
m in. 20 MOhm x km • AWG sizes are approximate equivalent
• Minimum bending radius p o ly m e r values. The actual cross-section is in mm2 .
• Screen of t inned cu braid, coverage approx.
flexing 7,5x cable 0 • unscreened analogue type:
85% KOMPOFLEX<~> JZ-500, see page A 87
fixed installation 4x cable 0 • Outer sheath, special thermoplastic
• Coupling resistance
p o ly m e r
max. 250 Ohm/km • Colour black <RAL 9005)
• Radiation resistance
• with meter marking, change-over in 2011
UP to 100x106 CJ/kg (UP to 100 Mradl
Application
Extremly robust universal cable.
This cable is specially installed in rubbish. sewage-treatment plants, composting works, animal stalls and greenhouses. The inner sheaths of
t hose cables raise the mechanical stress. Suitable for installation for flexible use for medium mechanical, stresses with free movement
without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type makes it
quick and easy to install.
This screened cable is ideal for use in data signal transmission free from interferences for measurement and control engineering technology.
EMC =Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x outer 0 Cop. Weight AWG·NO. Part no. No.cores x outer" Cop. weight AWG·NO.
approx. cross-sec. approx. Continuation •
26217 cross-sec. approx. mm weight kg 1 km 20 26245 approx. mm weight kg/ km
26218 20 26246
26219 mm• kg/km 68,0 20 26247 k g / km 98,0
26220 84,0 20 26248 102,0
26221 2 x0,5 6,9 41 ,0 95,0 20 26249 7,9 54,0 145,0
26222 107,0 20 26250 171,0
26223 5C0.5 7,2 45,0 135,0 20 26251 8,2 64.0 210,0
26224 195,0 20 26252 330,0
26225 4C0.5 7,8 54,0 278,0 20 26253 8,9 76,0 488,0
26226 310,0 20 26254 545,0
26227 5C0.5 8,5 66.0 406,0 20 26255 9,5 89.0 690,0
26228 520,0 20 26256 770.0
26229 7 C0.5 9.5 79.0 571,0 20 26257 11 ,0 114,0 811,0
26230 12 c 0,5 651,0 20 26258 996,0
26231 18 c 0.5 11,3 137.0 18 26259 13.1 186,0 1320.0
26232 760.0 18 26260 1480,0
26233 cc 13,1 156,0 911.0 18 26261 15.4 284,0 130,0
26234 18 26262
26235 20 0.5 13,8 173.0 88.0 18 26263 16,0 325.0 154,0
26236 25 0,5 98,0 18 26264 165,0
26237 30 c 0.5 15,7 250,0 112.0 18 26265 18,3 387,0 197.0
26238 130,0 18 26266 305.0
26239 34 c 0.5 16,0 297,0 18 26267 18.8 457.0 435,0
26240 185.0 18 26268 642,0
26241 42 c 0.5 17,4 316,0 294,0 18 26269 20.3 500,0
26242 18 26270 718.0
26243 50 c 0.5 18,9 360,0 357.0 18 26271 21,8 590,0 803,0
26244 404,0 18 26272 961,0
61 c 0.5 20.9 407.0 510,0 24.0 681.0 1060,0
22.9 520,0 561.0 26,2 710.0 1300.0
670.0 1677.0
2 X 0,75 7.6 46.0 960.0 8.4 64.0 1971,0
c 1104,0
3 c 0.75 7.8 57.0 1270,0 9.0 82.0
4 0,75
5 c 0,75 8.3 63.0 9.6 99.0
7 c 0.75 9.1 76.0 10.5 123.0
12 c 0.75 10.4 100.0 12.1 148.0
18 c 0,75 12.5 175.0 14.9 274.0
20 c 0,75 14.3 240.0 17.1 386.0
25 c 0,75 15,2 262.0 18.0 401.0
30 c 0,75 17.6 306.0 20,7 531.0
34 c 0.75 18,1 340.0 21,1 598.0
42 c 0.75 19.5 346.0 22.7 671.0
50 c 0.75 20,9 410.0 24.4 890.0
61 c 0.75 23.2 470.0 26.8 997.0
25.0 550.0 29.6 1120.0
c HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
KOMPOFLEX® JZ·SOO·CEMC·preferred type, meter marking halogen-free, microbes resistant, cu-screened, ~
MEOt
Part no. No.cores x Outer 0 Cop. Weight AWC·NO. Part no. No.cores x Outer 0 Cop. Weight AWC· NO.
26273 approx. mm w eight appro x. 14 26292 approx. mm weight approx.
26274 14 26293
26275 kgl km kgl km 14 26294 kg 1 km kg 1 km
26276 180,0 14 26295 730,0
26277 110,0 215,0 14 26296 17.8 367.0
26278 268,0 14 26297 1004,0
26279 148,0 349,0 14 26298 19,7 549.0 1170.0
26280 404.0 14 26299 1405,0
26281 169,0 710,0 12 :26300 21,6 604.0
26282 891 ,0 12 26301 894,0
26283 220,0 12 26302 24,0 820,0 1311,0
26284 1104,0 12 26303
26285 284,0 300,0 12 26304 20,7 653,0 1550.0
26286 12 26305 1820,0
26287 470,0 340,0 10 26306 22,6 807,0
26288 408,0 10 1430.0
26289 572,0 10 25,2 940,0 1894.0
26290 504,0 10 2272.0
26291 740.0 640.0 10 27,6 1345,0 2310,0
894,0 2740.0
124,0 26,0 920.0 3270,0
391,0 4080,0
178,0 28.9 1169.0
453.0
234,0 560,0 31,8 1420.0
680,0
284,0 33.4 1680.0
891.0
321 ,0 37,2 2020.0
581,0 38,2 2370,0
176,0 43,0 2880,0
245,0
316,0
442,0
530.0
Dimensions and specifications may be changed without prior notice. tRAOSl
Signal and power circular connectors
Series A, B, C, D, F and S
Tools
Accessories
Online configurator
Pre-assembled cables
You can find signal and power circular connectors in our catalog cable Accessories.
Request it now at www.hitechcontrols.com
C: HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
NANOFLEX® HC 500
NANOFL:EX® HC 500-C
NANOFLEX® HC TRONIC
N~NOFLEX® HC TRONIC-C
Photos: fotolia.com
Hygienic Cable
In the food and beverage processing industry sheaths. The cable is resistant to all standard
that is one of the most highly regulated detergents and offers good cleaning properties.
industries, hygiene is crucial. To achieve
complete hygiene security and to produce high- A FCN (Food contact Notification) has been
quality products all operational parameters have issued for the antimicrobial material used.
to be monitored continuously. For these special
A test certificate issued by the federal agency
environments we are now able to offer cables of material testing which approves the
with an antimicrobial outer sheath . The specially antimicrobial properties is available.
formulated insulation material helps to
prevent contamination from impurities and
the growth of micro-organisms on the outer
C HELUKABEL
HI-TECH (800) 677.8942 1 (303) 680.5159 www.hitechcontrols.com
CONTROLS_' INC.
Click or Call for a Quotel
NAN OF LEX® HC*SOO cut-resistant, meter marking
HELUKABEL NANOFLEXCI!> HC 500 3G1,5QMM/27071 300/SOOV 001091204 ( E
Ro@
Technical data Cable structure Properties
• Resistant to uv radiation, oxygen, ozone,
• Special polyurethane sheathed cable • Bare copper conductor, fine wire stranded
according to DIN VDE 0245, 0281 according to DIN VDE 0295 cl. 5, BS 6360 hydrolysis, microbes
cl. 5 or IEC 60228 cl. 5 • Self-extinguishing and flame retardant in
• Temperature range
flexing -5 oc to +80 oc • Special PVC core insulation Tl2 according accordance to VDE 0482-332-1-2, DIN EN
fixed installation -40 oc to +80 oc to DIN VDE 0281 Part 1 60332-1/ IEC 60332-1 (conforms to DIN VDE
0472 Part 804 Test method Bl
• Nominal voltage Uo/U 300/500 V • Black cores with sequential white • The materials used in manufacture are free
numbering in accordance with DIN VDE of silicone, cadmium and substances t hat
• Test voltage 4000 v 0293 Impair paint wetting
• Good cleaning properties
• Breakdown voltage • Green -yellow earth core in the outer layer, • Resistent to all standard detergents
3 cores and more
m in . 8000V Note
• Insulation resistance • Cores stranded in layers with optimal
lay-lengths • G =with green -yellow earth core;
m in . 20 MOhm x km x = without green-yellow earth core IOZl.
• Minimum bending radius • Outer sheath from special
fullpolyurethane TMPU according to • screened analogue type:
flexing 7,5x cable 0 NANOFLEX®HC 500-C, see page A 92
DIN EN 50363-10-2
fixed installation 4x cable 0 • Sheath colour - light grey IRAL 7035l • *Hygienic Cable
• Radiation resistance
• With meter marking
up to 100x106cJ/kg Jup to 100 Mradl
Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e.g. processing of dairy products, meat. f ish; production of convenience
foods, brewery and beverage industry
CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x outer" Cop. Weight AWG-No. Part no. No.cores x outer 0 cop. W eight AWG-No.
cross- sec. approx. mm w eight approx.
27031 mm• kg / km 20 27061 approx. mm weight approx.
27032 kg / km 20 27062 kg 1 km kg/ km
27033 2 X0.5 45.0 20 27063
27034 4,8 10.0 55,0 20 27064 6.6 38.0 75.0
27035 3G0.5 5,1 14,0 55,0 20 27065 7,1 48,0 89,0
27036 3 X0,5 65,0 20 27066 7,1 48.0 89,0
27037 4G 0,5 5,1 14.0 20 27067 8.6 67.0 115,0
27038 4 X 0,5 65.0 20 27068 8.6 67.0 115.0
27039 5G0,5 5.7 19,0 75.0 20 27069 10,2 96,0
27040 5 X 0,5 75.0 20 27070 10.7 115,0 166.0
27041 5.7 19,0 90.0 20 27071 12.9 173.0 201.0
27042 7 G0.5 6.2 24,0 90,0 20 27072 14,9 240,0 289,0
27043 7 X0,5 6.2 24.0 120,0 20 27073 6.2 29,0
27044 10 G0,5 7,2 34,0 135,0 18 27074 6.6 43,0 380.0
27045 12 G0.5 205,0 18 27075 6.6 43,0 68.0
27046 18 G0.5 7,2 34.0 270,0 18 27076 7.2 58,0 87,0
27047 18 27077 7.2 58.0
27048 25 G0.5 8.8 48,0 44.0 18 27078 8,2 72.0 87.0
27049 2 G 0.75 9,1 58.0 53,0 18 27079 8,2 72,0 106,0
27050 3 G0.75 10,7 86,0 53,0 18 27080 9.8 101,0
27051 18 27081 9.8 101,0 106.0
27052 3 c 0,75 13.2 120.0 64.0 18 27082 12.0 173.0 131,0
27053 64,0 18 27083 14.5 259,0 131,0
27054 4 G 0,75 5.4 14.0 18 27084 17.8 360,0
27055 76.0 18 27085 7,8 48,0 173.0
27056 4 X 0.75 5.7 22.0 76,0 18 27086 173.0
27057 5 G 0,75 96,0 17 27087 8.3 72.0 293.0
27058 5.7 22 .0 17 27088 9,2 96,0 454,0
27059 5 X 0.75 96,0 17 27089 10,1 120,0 641.0
27060 7 G 0,75 6.2 29.0 140.0 17 12,3 168,0 110,0
7 X 0,75 6.2 29,0 170.0 15,3 288,0 146,0
260,0 183,0
10 G 0.75 6.8 36.0 282,0 11,0 154,0
6,8 36.0 12,7 192,0 222.0
12 c 0,75 53,0 293,0
8.1 50.0 63,0
18 G 0.75 63,0 512.0
8.1 50.0 75,0 291.0
25 c 0,75 9,6 72.0 355,0
9,6 86.0
2 X1 11,9 130.0
14,5 180.0
3G1
3G1 5,7 19,0
4G1
6,0 29,0
6,0 29.0
6,6 38,0
Dimensions and specifications may be changed without p rior notice. !RA02>
C HELUKABEL
~HI-TECH (800) 677-8942 I (303) 680-5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
NANOFLEX® HC*SOO•C EMC preferred type, cut-resistant, screened, no inner
sheath, meter marking
_... HELUKABEL NANOFLEX® HC 500-C 3G,075QMMI27120 300/500V 001091104 C(
RoHS
Technical data Cable structure Properties
• Special polyurethane sheathed cable • Bare copper conductor. fine wire stranded • Resistant to uv radiation . oxygen. ozone,
according to DIN VDE 0245 part 201 to 1,5 according to DIN VDE 0295 cl. 5, BS 6360 hydrolysis, m icrobes
mm 2, cl. 5 or IEC 60228 cl. 5
according to DIN VDE 0245 part 102 from • Self -extinguishing and flame retardant in
2,5 mm2 • Special PVC core insulation Tl2 according accordance to VDE 0482-332-1-2, DIN EN
to DIN VDE 0281 Part 1 60332-1/ IEC 60332-1 <conforms to DIN VDE
• Temperature range 0472 Part 804 Test method Bl
flexing -5 octo +80 oc • Black cores with sequential white
fixed installation -40 oc to +80 oc numbering in accordance with DIN VDE • The materials used in manufacture are free
0293 of silicone, cadmium and substances t hat
• Nominal voltage Uo/U 300/500 V impair paint wetting
• Green-yellow earth core in the outer layer.
• Test voltage 3000 V 3 cores and more • Good cleaning properties
• Breakdown voltage • Resistent to all standard detergents
• Cores stranded in layers with optimal
min. 6000V lay-lengths Note
• Insulation resistance • Separating foil • G = with green-yellow earth core;
Min . 20 MOhm X km • Braided screening of t inned copper wires, x =without green-yellow earth core <OZl
• Minimum bending radius coverage approx. 85% • unscreened analogue type:
flexing 10x cable 0 NANOFLEX4D HC 500, see page A 91
fixed installation 5x cable 0 • Outer sheath from special
fullpolyurethane TMPU according to • *Hygienic Cable
• Radiation resistance DIN EN 50363-10-2
up to 100x106 cJ/kg <up to 100 Mradl
• Sheath colour - light grey <RAL 7035>
• coupling resistance
max. 250 Ohm/km • With meter marking
Application
screened special PUR cable for t he f ood and beverage industry; outer sheath with antimicrobial properties increases process reliability in all
applications in which food and beverages are processed unpacked and unsealed. e.g . processing of dairy products. m eat. f ish; production
of convenience foods, brewery and beverage industry
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
C€= The product is conformed with t he EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outer" Cop. Weight AWG·NO. Part no. No.cores x Outer" cop. Weight AWG - N o.
c r o ss-se c. approx. approx. mm w eight approx.
27105 approx. mm w eight kg / km 20 27135 kg/ km
27106 20 27136 kg / km
27107 kg/ km 47.0 20 27137 100,0
27108 57,0 20 27138 6,9 71,0 128,0
27109 5,3 35,0 57,0 20 27139 7,5 88,0 128.0
27110 60,0 20 271 40 7,5 88,0 157,0
27111 5,6 42.0 60,0 20 27141 8,9 111,0 157.0
27112 20 27142 8,9 111,0 230,0
27113 5.6 42.0 75.0 20 27143 10.7 150,0 262,0
27114 75,0 20 27144 10.9 184,0
27115 6,2 47.0 97.0 20 27145 13,0 260,0 381.0
27116 97,0 20 27146 15,9 349,0 535.0
27117 6,2 47,0 133,0 20 27147
27118 158.0 18 27148 6.6 63,0 87,0
27119 6,5 56,0 218,0 18 27149 6,9 80,0 102,0
27120 315,0 18 27150 6,9 80,0
27121 6.5 56.0 18 27151 7.5 97,0 102,0
27122 60,0 18 27152 7.5 97.0 127.0
27123 7,5 69,0 67,0 18 27153 8,4 119,0 127,0
27124 18 27154 8,4 119,0 159,0
27125 7,5 69,0 67,0 18 27155 10,0 147,0
27126 76.0 18 27156 10.0 147,0 159,0
27127 9,0 94.0 76.0 18 27157 12,1 267,0 207.0
27128 92,0 18 27158 14,6 374,0 207.0
27129 9.2 108.0 92.0 18 27159 17.9 526.0 340,0
27130 131,0 18 27160 8,2 96,0
27131 10,9 145.0 131,0 17 27161 8,6 144.0 480.0
27132 180,0 17 27162 9,6 148.0 704.0
27133 13.3 240.0 204,0 17 27163 10.6 181.0 131,0
27134 290,0 17 12,6 255,0 168,0
5,8 40.0 413,0 15,5 441,0 194,0
6,1 52,0 66.0 11.0 230,0 222.0
82,0 12.3 273,0 345,0
6,1 52.0 82,0 570,0
6,5 60,0 100,0 310,0
386,0
6,5 60.0
7,1 71,0
7,1 71.0
8,3 91.0
8.3 91.0
10,1 137,0
10,3 142,0
12,1 212,0
14,9 281.0
6.1 50.0
6,3 60,0
6.3 60.0
6,9 71,0
Dimensions and specifications may be changed without prior notice. <RA021
c HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols .com
Click or Call for a Quotel
~ CONTROLS, INC.
NAN 0 FLEX® H C*TRO N IC flexible, colour code to DIN 47100, meter marking
HELUKABEL NANOFLEX® HC TRONIC 7x0.34QMM/27202 001091147 ((
RoHS]
Technical data Cable structure Properties
• Special polyurethane data cable according • Bare copper, fine wire conductor, fine • Resistant to UV radiation, oxygen, ozone,
to DIN VDE 0245, 0812 wire stranded according to DIN VDE 0295 hydrolysis. microbes
cl.5 or 0245 or IEC 60228
• Temperature range • Self-extinguishing and flame retardant in
• Wire make-up for: accordance to VDE 0482-332-1-2, DIN EN
f lexing -5 oc to +80 oc 0,14 mm2 = 18x0.1 mm 60332-1/IEC 60332-1 <conforms to DIN VDE
0,25 mm2 = 14x0,15 mm 0472 Part 804 Test method Bl
fixed installation -40 octo +80 oc 0,34 mm2 = 7x0,25 mm
• The materials used in manufacture are free
• Peak operating voltage • Special PVC core insulation Tl2, to of silicone. cadmium and substances that
DIN VDE 0281 part 1 impair paint wetting
<not for purposes of high current and
• Core identification in accordance with DIN • Good cleaning properties
power installationl 47100, but without colour repetition • Resistant to all standard detergents
0,14 mm2 = 350 v • Cores stranded in layers with optimal Note
>=0.25 mm2 = 500 v lay-lengths
• screened analogue type:
• Test voltage • Outer sheath from special full NANOFLEX~HC TRONIC·C, see page A 95
to 0,25 mm21200 v
polyuretha ne TMPU according to • *Hygienic Cable
from 0,34 mm2 2000 V
DIN EN 50363-10-2
• Breakdown voltage • Colour light grey <RAL 7035l
to 0,25 mm22400 v • with meter marking
from 0,34 mm2 4000 V
• Insulation resistance
m in. 20 MOhm x km
• Operating capacity
<approx. valuel at 800 Hz
0,14 mm2120 pF/m
>=0,25 mm2 150 pF/m
• Inductance approx. 0,65 mH/km
• Impedance approx. 78 Ohm
• Minimum bending radius
f lexing 7,5x cable 0
fixed installation 4x cable 0
• Radiation resistance
up to 100x106 cJ/kg <up to 100 Mradl
Application
Special PUR data cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all
applications in which food and beverages are processed unpacked and unsealed, e.g. processing of dairy products. meat. f ish; production
of convenience foods, brewery and beverage industry
C€= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x outer B Cop . Weight AWC-No. Part no. No.cores x Outer B Cop. Weight AWC-No.
cross-sec. approx. mm weight approx. cr o ss -se c. approx.
27164 mm• kg / km 26 27180 mm2 approx. mm weight kg / km 24
27165 kg / km 26 27181 24
27166 2 X0,14 13.0 26 27182 2 X0,25 kg /km 18.0 24
27167 3 x0,14 3,3 3,0 16,0 26 27183 22.0 24
27168 4 X 0,14 3,5 4,0 19,0 26 27184 3 X0.25 3,8 5.0 26,0 24
27169 5 x0,14 3,7 5,0 26 27185 4 X 0.25 3,9 7.0 30,0 24
27170 6 X0,14 4,0 7,0 22.0 26 27186 5 X0.25 36,0 24
27171 7 x0,14 4,3 8,0 25.0 26 27187 6 X0,25 4.3 10.0 42,0 24
27172 8 X0,14 4,3 9,0 28.0 26 27188 7 X0,25 4,7 12.0 49,0 24
27173 10 X 0,14 5,1 11,0 35,0 26 27189 8 X 0,25 5,3 14,0 24
27174 12 X0,14 5,6 13,0 41.0 26 27190 57.0 24
27175 14 X 0,14 5.7 16,0 26 27191 10 X 0.25 5,3 17,0 66.0 24
27176 6,0 19,0 48.0 26 27192 12 X0.25 75.0 24
27177 16 X 0.14 6.5 22,0 53,0 26 27193 14 X0,25 5,7 19,0 84.0 24
27178 18 X 0.14 6.8 24,0 26 27194 72.0 24
27179 20 X 0,14 7.1 27.0 59.0 26 27195 16 X 0.25 6,6 24.0 84.0 24
21 )( 0,14 7.1 28,0 65.0 27196 18 X 0.25 101.0 24
24 X 0,14 7,5 32,0 70.0 19 X0.25 6.8 29.0 107.0
25 X0,14 7.7 34,0 77,0 20 x0,25 7.2 34,0 120,0 Continuation •
21 X0.25 132.0
87.0 24x0.25 7.6 38.0
91.0 25 X0.25 8,1 43.0
8.1 46.0
8,6 48.0
8,6 50.0
9,4 60.0
9,5 61,0
C HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
NANOFLEX® HC*TRON IC flexible, colour code to DIN 47100, meter marking
Part no. No.cores x Outer" Cop. Weight AWC·NO. Part no. No.cores x Outer" Cop. Weight AWC·NO.
cross-sec. approx. mm weight a pprox. cross-sec. approx. mm w eight approx.
27197 mm• kg / km 22 27218 mm• kg / km 20
27198 kg / km 22 27219 kg / km 20
27199 2 X0,34 22.0 22 27220 7 X0,5 81.0 20
27200 3 X0,34 4.2 7.0 30,0 22 27221 8x0,5 6,4 34.0 97.0 20
27201 4 X0,34 4,4 10,0 43,0 22 27222 10 X0,5 7,2 38,0 116.0 20
27202 54,0 22 27223 12 X0,5 135,0 20
27203 5 X0.34 4,8 13.0 22 27224 16 X 0,5 8 ,4 48.0 168,0 20
27204 6 X 0 ,34 58.0 22 27225 20x 0,5 8,4 58,0 213,0 18
27205 7 X0,34 5,4 16,0 61,0 22 27226 24 X0,5 241,0 18
27206 22 27227 10,0 77.0 18
27207 8 X0.34 5,9 20.0 73 .0 22 27228 2 X0,75 11,2 96.0 47.0 18
27208 10 x0.34 5,9 23.0 82,0 22 27229 3 X0,75 11,8 116.0 54,0 18
27209 12 X0,34 102,0 22 27230 18
27210 14 X0,34 7.0 26.0 108,0 22 27231 4 X0,75 5,2 14,0 66,0 18
27211 16 x0,34 7,6 33,0 126,0 22 27232 5 X 0,75 5,4 22,0 80,0 18
27212 18 X0,34 143,0 22 27233 110,0 18
27213 20 X0,34 7.7 39.0 160.0 20 27234 7 X0,75 5,9 29,0 125,0 18
27214 21 X0,34 8.4 46.0 166,0 20 8 X 0,75 6,7 36,0 148,0
27215 24 X 0,34 8.8 52,0 20 176,0
27216 9,3 59.0 186.0 20 10 X 0.75 7.3 50.0
27217 25 x0.34 9,9 65.0 192,0 20 12 X 0,75 8,6 58,0 220.0
2 x0,5 9.9 69,0 276,0
10.5 78,0 40.0 16 X 0,75 9,6 72,0
3 X0,5 10.7 82,0 46,0 20 X 0.75
4 x0,5 4,6 10,0 55,0 9.7 86.0
5 X0,5 4.8 14,0 64,0 11,6 115,0
6x0,5 5,4 19,0 73,0 12,4 144,0
5.9 24.0
6,4 29,0
Dimensions and specifications mav be changed w ithout prior notice. <RA02l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
NANOFLEX HC*TRONIC·C EMC preferred type, flexible, colour code to
DIN 47100, screened, meter marking
HELUKABE.L NANOFLEXe HC TRONIC.C 7.x0,34QMM127276 001091207 CE
Technical data Cable structure Properties
• Resistant to uv radiation. oxygen. ozone.
• Special polyurethane data cables for • Bare copper conductor, fine wire stranded
electronic control according to DIN VDE from 0,5 mm2 according to DIN VDE 0295 hydrolysis, microbes
0245,0812 cl.5 or 0245 or IEC 60228 • Self-extinguishing and f lame retardant in
• Temperature range • Wire make-up for: accordance to VDE 0482-332-1-2, DIN EN
0,14 mm2 = 18x0,1 mm 60332-1/ IEC 60332-1 <conforms to DIN VDE
f lexing -5 ·c to +80 •c 0,25 mm2 = 14x0,15 mm 0472 Part 804 Test method Bl
0,34 mm2 = 7x0,25 mm • The materials used in manufacture are free
f ixed installation -40 •c to +80 •c of silicone. cadmium and substances that
• Special PVC core insulation Tl2, according to impair paint wetting
• Peak operating voltage DIN VDE 0281 part 1 • Good cleaning properties
<not for purposes of high current and • Resistant to all standard detergents
power installation> • Core identification according to DIN 47100,
but without colour repetition Note
0,14 mm2 = 350 v
>=0,25 mm2 = 500 v • Cores stranded in lavers with optimal • unscreened analogue type:
lay-lengths
• Test voltage NANOFLEX®HC TRONIC, see page A 93
• Foil wrapping • *Hygienic Cable
core/core 1200 v • Drain stranded wire, tinned copper
core/screen 800 v
• Tinned copper braided screening, coverage
• Breakdown voltage approx. 85%
min. 2400 V
• Outer sheath from special full polyurethane
• Insulation resistance TMPU according to DIN EN 50363-10-2
min. 200 MOhm x km
• Sheath colour - light grey <RAL 7035)
• Operating capacity
<approx.-valueJat 800Hz • With meter marking
core/core at 0,14 mm2 = 120 pF/m
core/core >=0,25 mm2 =150 pF/m
core/screen at 0,14 mm2 = 240 pF/m
core/screen >=0,25 mm2 =270 pF/m
• Inductance approx. 0,65 mH/km
• Impedance approx. 78 Ohm
• coupling resistance max. 250 Ohm/km
• Minimum bending radius
f lexing 10x cable 0
f ixed installation 5x cable 0
• Radiation resi stance
up to 100x106 cJ/kg <up to 100 Mradl
Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed. e.g. processing of dairy products. meat. fish; production of convenience
foods. brewery and beverage industry
EMC = Electromagnetic compatibillitv
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EG
Pa rt no. No.cores x outer" Cop. Weight AW G·No. Part no. No.cores x outer" Cop. Weight AWG·No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm w eight approx.
27235 mm• kg / km 26 27252 mm• kg/ km 24
27236 kg tkm 26 27253 kg / km 24
27237 1 X0,14 16.0 26 27254 1 X0.25 27.0 24
27238 2 X0,14 2.5 6,0 20,0 26 27255 2 X0,25 2.9 7,0 31,0 24
27239 3 X0,14 27,0 26 27256 3 X0,25 4,2 16,0 36,0 24
27240 4 X0,14 3.7 12.0 26 27257 4 X0,25 40,0 24
27241 5 X0,14 3,9 13.0 32.0 26 27258 5 X0 ,25 4,3 19,0 24
27242 6 X 0,14 37.0 26 27259 6 X 0,25 51.0 24
27243 4.1 15.0 42,0 26 27260 7 X0 ,25 4,7 22.0 58,0 24
27244 7 X0.14 48,0 26 27261 8 X0,25 64,0 24
27245 8 X0,14 4.4 16.0 55,0 26 27262 10 X0,25 5.3 27.0 24
27246 10 X0.14 4,9 18.0 65,0 26 27263 12 X0,25 5,7 32.0 82.0 24
27247 12 X0,14 4,9 19.0 26 27264 14 X0,25 5,7 35,0 85,0 24
27248 14 X0,14 5,2 21.0 77.0 26 27265 16 X0,25 90,0 24
27249 16 X0.14 6.2 29,0 79.0 26 27266 18 X 0,25 6,6 42.0 144,0 24
27250 18 X 0,14 89,0 26 27267 19 X 0,25 7,2 50,0 24
27251 20 X0,14 6.2 31.0 103,0 26 27268 20 X0,25 110.0 24
21 X0 ,14 6,6 32,0 116,0 21 X0,25 7,3 58.0 142.0
24 X0,14 24 X0,25 7,9 62.0 146.0 Continuation •
25 X0,14 6,9 43,0 120.0
131,0 8.3 67.0 88,0
7,2 51.0 8,9 78.0 150,0
7,7 55.0 136.0 9,1 79.0 163,0
7,9 56,0 9,4 152.0
9,4 91,0
8,3 62.0
8.5 61,0 10.0 96,0
c HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
NAN OF LEX HC*TRONIC·C EMC preferred type, flexible, colour code to
DIN 47100, screened, meter marking
Part no. No.cores x Outer 0 cop. weight AWG·NO. Part no. No.cores x outer0 cop. weight AWG·NO.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
27269 mm• kg/km 24 27294 mm• kg/km 20
27270 kg/km 22 27295 kg / km 20
27271 25 X 0.25 169.0 22 27296 7 x0.5 98.0 20
27272 1 X 0,34 10.1 99.0 24,0 22 27297 8x0,5 7.3 68.0 117.0 20
27273 2 X0,34 3,2 13,0 30,0 22 27298 10x0.5 8,5 80,0 135.0 20
27274 3 x0,34 4,8 18,0 37,0 22 27299 12 X0,5 157.0 20
27275 4 X 0,34 5,2 22.0 48,0 22 27300 14 X0,5 9.2 93.0 190.0 20
27276 5 x0,34 5,5 28,0 54,0 22 27301 16X0,5 9.5 117,0 210.0 20
27277 6 x0,34 6,0 31,0 61 ,0 22 27302 18 X 0,5 10.0 122.0 217.0 20
27278 7 x0,34 6,7 45,0 67,0 22 27303 19 X 0,5 10.6 129,0 246,0 20
27279 8 x0,34 6,7 51.0 81,0 22 27304 20x0,5 10.7 152,0 20
27280 10 X 0,34 7,8 54,0 22 27305 11,2 156.0 275.0 18
27281 12 X 0.34 8,4 65,0 103.0 22 27306 24 x0.5 11.9 173,0 337.0 18
27282 14 X0,34 8,5 70,0 110,0 22 27307 25 X 0,5 12.6 256,0 351.0 18
27283 16 X0.34 9,0 81,0 153,0 22 27308 12.7 250.0 41,0 18
27284 18 X0,34 9,4 88,0 159,0 22 27309 1 x0,75 3.8 19,0 18
27285 19 X 0,34 9,8 103,0 22 27310 2 X0,75 6,0 38,0 59,0 18
27286 20x 0,34 172.0 22 27311 3 X0,75 6,2 50,0 66,0 18
27287 10.1 106.0 181,0 22 27312 4 X 0,75 6 ,7 57,0 77,0 18
27288 21 X0.34 10,1 112.0 191,0 20 27313 5 X0,75 7,3 70,0 18
27289 24 X 0,34 10,7 116,0 199,0 20 27314 6x0,75 8,1 87,0 93.0 18
27290 25 X 0,34 10,7 129,0 229,0 20 27315 7 x0,75 113.0 18
27291 12,0 120,0 241,0 20 27316 8 X0,75 8 ,2 96,0 130,0 18
27292 1 X0,5 20 27317 10 X0,75 9 ,0 110,0 145,0 18
27293 2 xo.s 3.4 15,0 40,0 20 27318 12 X0,75 10,3 140,0 180,0 18
3x0.5 5,3 29,0 45,0 27319 14 X 0,75 10.4 151,0 202,0 18
4x0,5 5,6 39,0 55,0 27320 16 X0 ,75 11,2 167,0 225,0 18
5 X 0,5 6,0 46,0 61,0 27321 18 X0,75 275,0 18
6x0.5 19 X0,75 11 ,8 183,0 292,0
6,7 52.0 76,0 20x0,75 12,6 207,0 322,0
7.3 66.0 89.0 24 X0,75 12,6 221 ,0 362,0
25 X0,75 13,1 238,0 435,0
14,1 270,0 415,0
14.3 278,0
Dimensions and specifications may be changed without prior notice. <RA02l
C HELUKABEL
(800) 677·8942 I (303) 680·5159 www. hitechcontrols .com
Click or Call for a Quotel
-I
Photo· HELUKABEl"
Data and computer Cables
C HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
CONTROLS_' INC. Click or Call for a Quotel
Data and Computer Cables
Due to the increasing data transfer between
machines and equipment the higher standards in
data and computer applications are necessary.
Besides standard processes the requirement
of precise data transfer must be the first and
foremost.
Depending on the requirement, the HELUKABEL®
customer can choose the data or computer cable
from an extensive stock, where almost al l cable
constructions are ex stock.
Depending on the required application, solid,
flexible or highly flexible constructions with
corresponding screen ing may be necessary.
In this case our technical advisors are ready to
inform you.
We can also manufacture cables according to your
specific requirements with a min imum order
quantity. For special enquiries please fi ll-in our
attached enquiry form.
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
contents
Description------------------------------------------------------------------------------- Page
TRON IC <LiYYl, f lexible, colour coded to DIN 47100, meter marking .... ......... ........... .... .............. .... ....... ........................... ............................. ... '!P 84
86
PAAR· TRON IC, flexible, colour coded to DIN 47100, meter marking .............. ........ ..... ................ ..... ... ............. ........ ...... .... ... .... ......... ............ ~ 88
89
DATAFLAMM, halogen-free, meter marking .. ............ ..... .. ... .... ... .. ....... ........ .. ... .... ............ .... .... .. .... ........... .. ... ....... ................... .................. . 811
TRON IC·CY (LiY·CYl, f lexible. cu-screened, colour coded to DIN 471DO. EMC-preferred type, meter marking ........... ............... .. ... ........ ............. ... .... ~ 813
814
PAAR·TRONIC·CY, flexible, cu-screened, colour coded to DIN 47100. EMC-preferred type, meter marking ..................... ............. .... ... .. ........... ..... .. '!P 816
817
PAAR·CY·OZ, flexible. cu-screened . EMC-preferred type, meter marking ... ............. ........ ...... .... ... .... ......... ......... ... ~ 818
819
PAAR· TRON IC·CY·CY (LiYCY·CYl, EMC-preferred type, meter marking ..... ... . ..... ... .. ....... .... .... ........ .................. ....... ............ ...... .. ..... ..... ..... . 8 20
8 21
PAAR· TRON IC·Li·2YCYv, PE-lnsulated. low capacitance, Termi-Point", EMC-preferred type, meter marking .......... ..... .... ........ .... .............. ....... ......... .. 8 22
8 23
PAAR·TRONIC·Li·2YCY, PE-insulated, low capacitance. Termi-Point", EMC-preferred type, meter marking ..... ....... ............................... .... ........ .......... 8 24
825
LifYCY , high flexible, paired. screened. EMC-preferred type, meter marking 8 26
8 27
TRON IC 1 -CY, each core individually screened . EMC-preferred type, meter marking 8 28
829
TRON IC 2 -CY, 2 cores screened, meter marking ......... ..... .. ....... ............ ............................. ........................ ..... .......................... ... ............... . 830
8 31
LiY •TPC·Y, pairs screened. EMC-preferred type, meter marking .. ... ............ ..... .. . .......... ............ ............. ................. ......................... ........ ........... 8 32
8 33
DATAPUR·C, EMC-preferred type, cu-screened . PUR-outer jacket. meter marking ... ........ .... ..... ......... ... ..... ... .......... ... ..................... ..... ....... ...... ... ... 8 34
DATAFLAMM ·C, EMC-preferred type, halogen-free, screened. meter marking .. ... .. ..... .... ....... .. .... .............................. ....... ............ ...... .. ..... ..... ..... .
DATAFLAMM·C·PAAR, EMC-preferred type, halogen-free. screened, meter marking .. ............. .... ............ ............. .... .... ................. .... .................. .
EDV· P iMF·CY, PE-insulated, low capacitance. EMC-preferred type, meter marking
RD · Y<StlY, Instrumentation Cable suitable for Maxi-Term -Point"-connection. meter marking .........
RD ·Y<StlYV I RD ·Y<StlYY , reinforced !double! outer jacket. instrumentation cable, Maxi-Termi-Point", meter marking
RE · 2Y<StlYv, Instrumentation cable. reinforced outer Jacket, meter marking ..... .... ........ .... .. .................. .. ... .......... ... ......... ... .. ...... .. ........... ........ ~
RE · 2Y<StlYV PiMF, Instrumentation cable, pairs screened, reinforced outer jacket, meter marking .......... .... ......................... ... .. .... ........ ............. .. ~
J·2Y(StlY, St Ill Bd 16 Mbits/s !Kat. 31 ISDN/EDV IZ =1DO Ohm!, meter marking
JE·Y<StlY, Bd Si lndustry-Eiektronic Cable according to DIN VDE 0815 ......... ..... ....... ..... .... .... ......... ....... ....... .. .... .............. .... ... .. ... ......... ....... .. .. .Q.
JE·LiYCY, Bd Si lndustry-Eiektronic Cable according to DIN VDE 0815 .. ... ................. ..... ........................ .. ... ........ .............. ........................ ........ .Q.
JE·LiHCH, Bd Industry electronic cable, halogen-free. according to VDE 0815 ........ .. ... ........ ..... ... .... .. ....... .... .. .................... ........ ........ ........ ........ .Q.
RD·H<STlH, Bd Instrumentation cable. halogen-free ... ... ..... .. . .. .... ............ ..... ... ..... .... ................. ............. ... ......... .... ........ .. .. .... .......... ......... ......
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
flexible. colour coded to DIN 47100, meter marking ~
TRONIC (LiYYJ
MEOI
CE
RoHS
Technical data Cable structure Properties
• Special PVC data cables. adapted to • Bare copper, f ine wire conductors. bunch • Extremely oil resistant, oil-/ chemical
DIN VDE 0812 stranded to DIN VDE 0295 cl. 5 and Resistance - see table Technical
IEC 60228 cl. 5 Informations
• Temperature range
flexing -5 oc to +80 oc • Conductor make-up for • PVC self-extinguishing and f lame retardant
0,14 mm2 = 18x0,1 mm according to VDE 0482-332 -1-2, DIN EN
fixed installation -40 octo +80 oc 0,25 mm2 = 14x0,15 mm 60332-1-2/ IEC 60332-1 (equivalent
• Nominal voltage 0,34 mm2 = 7x0,25 mm DIN VDE 0472 part 804 test method Bl
(not for purposes of high current and • Special PVC core insulation Tl2, to • The materials used in manufacture are
power installation> DIN VDE 0281 part 1 cadmium-free and contain no silicone and
free from substances harmful to the
0.14 mm2 =350 v • Colour coded to DIN 47100. but without wetting properties of lacquers
~0.25 mm2= 500 v colour repetition
Note
• Test voltage • Cores stranded in layers with optimal
up to 0,25 mm2 1200 V lay-length • AWG sizes are approximate equivalent
from 0,34 mm2 2000 v values. The actual cross-section is in mm2.
• Special PVC outer sheath TM2, to
• Breakdown voltage DIN VDE 0281 part 1 • HELUKABEL®-TRONIC is also available in
up to 0,25 mm2 2400 v paired version (e.g.
from 0,34 mm2 4000 V • Colour grey (RAL 7001 l HELUKABEL®-PAAR-TRONIC 20X2X0,14 mm2l.
• with meter marking, change-over in 2011
• Insulation resistance • screened analogue type:
m in. 20 MOhm x km TRONIC·CY (LiY·CY), see page B 9
• capacitance (approx.-valuel at 800Hz
0,14 mm2 120 pF/m
;::0,25 mm2 150 pF/m
• Inductance approx. 0.65 mH/km
• Impedance approx. 78 Ohm
• Minimum bending radius
flexing 7.5x cable 0
fixed installation 4x cable 0
• Radiation resistance
up to 80x106 cJ/kg (up to 80 Mradl
Application
These cables are used for f lexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but
not suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use.
This applies especially to such areas as tool making and machine industries as well as electronic, computer. measurement and control sectors.
<E= The product is conformed with t he EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outer 0 cop. weight AWC-No. Part no. No.cores x outer 0 Cop. weight AWC-NO.
cross-sec. approx. cross-sec. approx.
18001 mm• approx. mm weight kg/km mm• approx. mm weight kg/km 24
18002 24
18003 2 X 0,14 kg / km 13,0 2 X 0,25 kg/km 18.0 24
18004 3 X0,14 16,0 22.0 24
18005 4 X 0 ,14 3,3 2.7 19,0 26 18029 3 X0,2"5 3,8 4,8 26.0 24
18006 26 18030 4 X 0.25 30,0 24
18007 5 X0.14 3,5 4,0 22.0 26 18031 5 X0.25 3,9 7.2 36,0 24
18008 6 X0,14 25,0 26 18032 6x 0,25 24
18009 3,7 5.4 26 18033 7 X0,25 4,3 9,6 42,0 24
18010 7 X0,14 28.0 26 18034 8 X0,25 49,0 24
18011 8 X0,14 4,0 6,7 35,0 26 18035 10 X 0,25 4,7 12,0 24
18012 26 18036 12 X 0,25 57,0 24
18013 10 X0,14 4,3 8,1 41.0 26 18037 5,3 14.4 66,0 24
18014 12 x0.14 48,0 26 18038 14 X0,25 24
18015 14 X0,14 4,3 9.4 53,0 26 18039 16 X0,25 5,3 16,8 75.0 24
18117 16 X0,14 59,0 26 18040 84,0 24
18016 18 x0,14 5,1 10,7 26 18114 18 X0.25 5.7 19,2 72,0 24
18017 20 X0,14 65,0 26 18041 19 X0,25 84,0 24
18018 21 x0,14 5,6 13.4 70,0 26 18042 20 X0,25 6,6 24.0 24
18019 24 X0,14 26 18043 101,0 24
18020 5.7 16,1 77,0 26 18118 21 X0.25 6,8 28,8 107.0 24
18021 25 X0,14 87,0 26 18044 24 X 0,25 120,0 24
18022 27 X0.14 6,0 18,8 26 18045 25 X 0,25 7.2 33,6 132.0 24
18023 30 x 0,14 91.0 26 18046 140.0 24
18024 32 X0,14 6,5 21,5 97.0 26 18047 27 X0,25 7,6 38,4 156.0 24
18025 108.0 26 18115 30 X0.25 164.0 24
18026 36 x0,14 6,8 24.2 114.0 26 18048 32 X0.25 8,1 43.2 182.0 24
18027 40 X0.14 126.0 26 18049 36 X0.25 190,0 24
18028 42 x0,14 7,1 26,9 139.0 26 18050 37 X0.25 8,1 46,0 200.0 24
146.0 26 18051 40 X0.25 211,0
44 X0.14 7,1 28,2 153.0 26 18052 42 X 0,25 8,6 48,0 225.0 Continuation •
48 X0,14 164.0 26 18053 44 X 0,25 245.0
7.5 32,3 173,0 26 18054 8,6 50,0 263.0
52 X0.14 187,0 48 X0,25 280.0
56 x 0,14 7.7 33,6 c HELUKABEL 52 X0.25 9.4 60.0 305.0
61 X0,14 204.0 56 X0.25
80 x0,14 7,7 36.3 280.0 61 X0,25 9,5 61,0
370,0
100 X0.14 8.5 40.3 9.5 65.0
8.8 43,0 10.3 72.0
9,3 48.4 10,9 77,0
9.6 54,0 11,3 86.0
9.9 56.0 11,3 89,0
10.4 59.0 11,6 96.0
10,5 65,0 12.0 101,0
11,0 70,0 12,6 106,0
11,3 75,0 12.7 115.0
11.6 82,0 13,3 125,0
13.0 108,0 13,9 134.0
14.7 135.0 14.3 146.0
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
flexible. colour coded to DIN 47100, meter marking ~
TRONIC (LiYY) MEOI
Part no. No.cores x Outer" Cop. Weight AWC·NO. Part no. No.cores x Outer" Cop. Weight AWC·No.
c r o ss-se c. approx. approx.
18055 mm• approx. mm w eight kg /km 24 18085 approx. mm weight kg /km
18056 24 18086
18057 80 x0.25 kg / km 450,0 22 18087 kg 1 km 40,0
1805"8 100x0,25 590,0 22 18088
18059 16.5 192,0 22 18089 4,6 9.6 46.0
18060 2 X 0,34 22,0 22 18090 55.0
18061 18.2 240.0 22 18091 4,8 14,4 64.0
18062 3 X0,34 30,0 22 18092 73.0
18063 4 X 0.34 4.2 6,5 43.0 22 18093 5.4 19.2 81,0
18064 5 X0,34 54,0 22 18103 97,0
18065 6 X0.34 4,4 9,8 58,0 22 18101 5,9 24,0 116,0
18066 7 x0,34 22 18094 135,0
18067 8 x0.34 4.8 13,1 61,0 22 18102 6,4 28,8 168,0
18068 10 X 0,34 73.0 22 18095
18069 12 X 0.34 5,4 16,3 82.0 22 18104 6.4 33,6 213.0
18070 14 X0,34 102,0 22 18097 241.0
18071 16 X 0,34 5,9 19,6 22 18098 7,2 38.4 303.0
18096 18 X0,34 108,0 22 18099 391,0
18072 20x0.34 5 .9 22,8 126.0 22 18100 8,4 48,0
18073 21 x0,34 143,0 22 18105 47,0
18074 7.0 26.1 160,0 22 18106 8,4 58,0 54.0
18075 24 X 0.34 166.0 22 18107 66.0
18116 25 X 0,34 7.6 32,6 186.0 22 18108 10.0 77,0 80,0
18076 27 X 0.34 192,0 22 18109 110,0
18077 30 X0,34 7,7 39,2 206.0 22 18110 11.2 96.0 125.0
18078 32 X 0,34 226.0 22 18111 148,0
18079 36 x0,34 8.4 45.7 245.0 22 11,8 116,0 176,0
18080 37 X 0.34 285.0 22 1811'2 220,0
18081 40x0,34 8.8 52.0 292,0 22 13,2 144,0 276,0
18082 22 18113
18083 42 X 0.34 9,3 59.0 318.0 22 15,2 192.0 56.0
18084 44 x0,34 330.0 22 71,0
48 x0.34 9,9 65,0 370.0 5,2 14,4
52 X0,34 405,0 75,0
53 X 0,34 9,9 69,0 430,0 5.4 21,6
61 X0,34 440.0 90.0
80 x0,34 10.5 78.0 610.0 5.9 29,0
100X0.34 880,0
10.7 82,0 1050,0 6,7 36,0
10.7 88.0 7.3 50,0
11,8 98.0 8,6 58,0
11,8 104.0 9.6 72,0
12,9 118,0 9,7 86,0
12,9 121.0 11.1 115,0
13.3 131,0 12,4 144,0
14,0 137.0 5,5 19,2
14,0 144,0 5,8 29.0
14,7 157,0 6.2 29.0
15,4 170,0 6.7 43,0
15.4 183,0
16.3 199.0
18.8 264,0
21,0 327.0
Dimensions and specifications may be changed without prior notice. <RB01J
Standardised process control and visualisation
of an extrusion system at our Windsbach factorv.
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
flexible, colour coded to DIN 47100, meter marking ~
PAAR·TRONIC MEOI
HELUKABEL PAAR·TRO NIC Sx2x0,25 QMM / 19038 001042302 (E
RoHSj
Technical data Cable structure Properties
• Special PVC data cables, adapted to • Bare copper, fine wire conductors. bunch • Extensively oil resistant, oil-/ chemical
DIN VDE 0812,0814 stranded to DIN VDE 0295 cl. 5 and Resistance · see table Technical
IEC 60228 cl. 5 Inf o r m a t i o ns
• Temperature range
• Special PVC core insulation Yl2. to • PVC self-extinguishing and flame retardant
f lexing ·5 oc to +80 •c DIN VDE 0207 part 4 according to VDE 0482-332·1-2, DIN EN
fixed installation -30 •c to +80 oc 60332·1·2/ IEC 60332-1 (equivalent
• Colour coded to DIN 47100 DIN VDE 0472 part 804 test method 8)
• Nominal voltage 250 v
• Test voltage 1200 v • Cores stranded in pairs with optimal • The materials used in manufacture are
lay-length cadmium -free and contain no silicone and
• Breakdown voltage m in . 2400 V free from substances harmful to the
• Pairs stranded in layers with optimal wetting properties of lacquers
• Insulation resistance lay-length
min. 20 MOhm x km Note
• Core wrapping with foil
• Capacitance (approx.-valuel at 800Hz • AWG sizes are approximate equivalent
• Special PVC outer sheath YM2, to values. The actual cross-section is in mm2.
core/core 0,14 mm2=120 pF/m DIN VDE 0207 part 5
• screened analogue type:
core/core 0,25 mm2= 150 pF/m • Sheath colour grey (RAL 7032l PAAR· TRONIC·CY, see page 811
• Load 0,14 mm2 =1,5 A • with meter marking, change-over in 2011
0,25 mm2 =2,5 A
• Inductance approx. 0,65 mH/km
• Impedance approx. 78 Ohm
• K1·coupling approx. 300 pF/100 m
• Minimum bending radius
flexing 7.5x cable 0
fixed installation 4x cable 0
• Radiation resistance
up to 80x106 cJ/kg (up to 80 Mradl
Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet
rooms but not suitable for open air. PAAR·TRONIC is the perfect cable for use in areas where a small diameter is essential to complete wiring.
E. g. as a control and signal cable in measuring instruments. computers. signal transfer etc. This cable is suitable only for low load application.
CE= The product is conformed with t he EC Low-Voltage Directive 2006/95/EG.
Part no. No.pairs x Outer" Cop. Weight AWC·NO. Part no. No.palrs x outer" Cop. W eight AWC•NO.
cross-sec. approx. mm weight approx. cross-sec. approx.
19001 mm• kg / km 26 19018 mm• approx. mm weight kg/ km 26
19002 kg/ km 26 19019 24 x2x0,1 4 26
19003 1 x2 x0,14 20.0 26 19020 25x2x0.14 kg I km 170,0 26
19004 2 X2 X0,14 3,5 2,7 25,0 26 19021 26 x 2 x 0 ,1 4 180,0 26
19005 3 X2 X0,14 31 ,0 26 19022 27 x2 x0,14 12.4 65,0 184,0 26
19006 4 x 2 x0,14 5,1 5.4 26 19023 28 X2 X0,1 4 188,0 26
19007 5 X2 X0,14 38.0 26 19024 30 X2 X0,14 12,5 67,0 192.0 26
19008 6x2x0,14 5.2 8.0 45,0 26 19025 32 x2 x 0 ,14 26
19009 7 x2x0.14 5.6 10,7 26 19026 34 X2 X0,14 12,5 70,0 200.0 26
19010 8x2 x0,14 6.6 13,4 50.0 26 19027 36x2 x0,14 224,0 26
19011 10x2 x0,14 6.9 16,1 57,0 26 19028 38X2X0.14 12,7 73,0 247,0 26
19012 11x2x0.14 26 19029 40x 2 x 0 ,1 4 26
19013 12 x 2 x0,14 6.9 18.8 64.0 26 19030 44x2x0,14 12,8 75,0 260.0 26
19014 14x2x0,14 7.5 21,5 78,0 26 19031 45 X2 X0,1 4 272,0 26
1 90 1 5 15 x 2x0,14 86,0 26 19032 50 X2 X0,14 13,1 81,0 294,0 26
19016 16x2 x0,14 8.6 26.9 94,0 26 19033 52 x2 x 0 ,1 4 334,0 26
19017 18x2 x0,14 8,7 29,5 105.0 26 55x2 x0,14 13,5 86.0 342,0
20 X2 X0,14 108,0 387,0
22 x2 x0,14 8.9 32.3 110.0 14,0 91,0
119.0 403.0
9.6 37.6 130,0 14,2 97,0 427,0
9.8 40,3
10.1 43.0 150.0 14.3 102.0
10.4 48,4
15,0 108,0
10,8 54.0
11,6 59.0 15,9 118,0
15,9 121,0
16,5 134,0
16.9 140,0
17,5 148,0
Continuat ion •
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
PAAR•TRON IC flexible, colour coded to DIN 47100, meter marking ~
ME01
Part no. No.palrs x Oute r 1!1 Cop. weight AWC·NO. Part no. No.palrs x outer 1!1 Cop. weight
c:ross-sec:. approx. c:ross-se c:. a pprox. AWC·NO.
19034 mm• kg/km 24 19057 mm• kg/km
19035 approx. mm weight 24 19058 approx. mm weight
19036 1 x 2 x0.25 32.0 24 19059 32 X2 X0.25 410.0
19037 2 X2 X0,25 kg 1 km 37,0 24 19060 34 X2 X 0,25 kg/km 425,0
19038 3 X 2 X 0,25 24 19061 36 X 2 X 0,25 440,0
19039 4.0 5.0 47.0 24 19062 16.5 160,0
19040 4 X 2 X 0.25 6,0 10,0 58.0 24 19063 38 X2 X0,25 480,0
19041 5 X2 X0.25 70.0 24 19064 17,2 170,0
19042 6 x2 x0,25 80,0 24 19065 40X 2 X0.25 530.0
19043 7 X 2 X 0,25 6.3 15.0 24 19066 44 X2 X0,25 17.3 180.0 580,0
19044 89.0 24 19067 45 X 2 X 0,25
19045 8 X 2 X0,25 6.8 20,0 24 19068 17.6 190,0 600.0
19046 10x2 x0.25 99.0 24 19069 50 X2 X0.25 650.0
19047 7,8 25.0 114,0 24 19070 52 X 2 X0 .25 18.3 200.0
19048 11 x2x0.25 8,3 30,0 126,0 24 19071 55 X2 X0,25 670.0
19049 12x2x0.25 24 19072 19.7 220,0 7900
19050 14x2x0.25 137.0 24 19073 1 X2 X0 .34
19051 15 X2 X 0,25 8.3 35.0 161 .0 24 19074 2 X 2 X0,34 19.7 225.0 36.0
19052 174.0 24 19075 42.0
19053 16X2X0.25 9.3 40.0 24 19076 3 X 2 X 0.34 20.4 250.0 50.0
19054 18x2x0.25 187,0 24 19077 4 x 2 x0.34
19055 20 x2 x0.25 10.5 50.0 212.0 24 19078 20.8 260.0 61.0
19056 10,6 55,0 234.0 24 1 X 2 X 0,5 42.0
22 x 2 x0.25 250,0 2 X2 X0,5 21 5 275,0 51.0
24 X2 X 0,25 62,0
25 X 2 X 0,25 10,8 60.0 280.0 3 X2 X 0.5 4,4 6.5
300.0 4x 2 x o.s 73,0
26x 2 x0.25 11,6 70.0 320,0 1 X 2 X 0,75 6,9 13,1
27 X 2 X 0,25 2 X2 X 0,75 47 .0
28 X 2 X0,25 12.0 75.0 330.0 7.0 19.6 59.0
30 X2 X0,25 12,5 80,0 345.0 3 X 2 X 0 ,75 74,0
370.0 4 X2 X 0,75 7.8 26"1 93,0
12.8 90.0 4.6 9.6
13.3 100.0 7.6 19,2
14,0 110.0 7.7 28,8
15.0 120.0 8,6 38,4
15.3 125.0 5.2 14.4
15,3 130,0 8,5 28.8
15,5 135,0 8.6 43.2
15.7 140,0 9,6 57.6
16.1 150.0
Dimensions and specifications may be changed without prior notice. <RB01 l
Drag Chain Systems
Open chains
Closed chains
Accessories
Installation instructions
Selection tables
You can find drag chain systems in our catalog Cable Accessories.
Request it now at www.hitechcontrols.com
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
DATAFLAMM halogen-free, meter marking
RoHS
Technical data Cable structure Properties
• Special data cable • Bare copper. fine wire conductors to • Halogen-free according to VDE 0482
• Temperature range DIN VDE 0812, conductor make-up for part 267/ DIN EN 50267-2-1/ IEC 60754-1
0,34 mm2 - 7x0,25 mm <equivalent DIN VDE 0472 part 815)
f lexing +5 octo +70 oc
fixed installation -40 octo +70 oc • PE-insulation. compound type 2YJ1 to • Corrosiveness of combustion gases
DIN VDE 0207 part 2 according to VDE 0482 part 267/
• Nominal voltage DIN EN 50267-2-2/ IEC 60754-2 <equivalent
• Cores colour coded to DIN 47100 DIN VDE0472 part 813)
0,14 mm2 = 350 v • Cores twisted in layers w ith optimal
• Halogen-free sheath compound.
>0,14 mm2 = 500 v lay-length self -extinguishing and flame retardant
• Test voltage according to DIN VDE 0482 part 265-2-1 /
• Halogen-free outer sheath. to EN 50265-2-1/ IEC 60332-1 <equivalent
0.14 mm2 =800 v DIN VDE 0207 part 24, compound type HM2 DIN VDE0472 part 804 test method B>
>0.14 mm2 = 1200 v • Sheath colour grey, RAL 7005
• Insulation resistance
• with meter marking, change-over in 2011
m in. 2 GOhm x km
• capacitance Note
core/core <70 nF/km • screened analogue type:
• Minimum bending radius DATAFLAMM-C, see page B 23
approx. 7,5x cable 0
• Radiation resistance
up to 100x1os cJ/kg <up to 100 Mrad>
Application
DATAFLAMM halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom
speaking systems. clock installations. electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable
for installation in dry, damp and wet environments as well as in masonry and concrete.
PE-insulated-cores, compared w ith the conventional PVC-insulated cores. assure a remarkable and more favourable capacitance values.
These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, t rading
centres where t he freedom f rom halogen in case of fire and the flame propagation must be avoided.
The halogen-f ree t hermoplastic sheath produce neither corrosive nor toxic gases.
CE= The product is conformed with t he EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x Outerl!l cop. weight AWC-No. Part no. No.cores x outer Ill cop. weight AWC-NO.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
52300 mm• kg/km 26 52330 mm• kg/km
52301 kg / km 26 52331 kg 1 km
52302 2 X 0.14 14,0 26 52332 4 X 0,34 35,0
52303 3 X 0,14 3,3 2.6 26 52333 4.9 13,0
52304 4 X 0 .1 4 17.0 26 52334 5 x0.34 43,0
52305 5 X0.14 3.5 4.0 19.0 26 52335 7 X 0,34 5.4 16.4 58.0
52306 6 X 0,14 3.7 5.3 23,0 26 52336 5.9 22.7 80,0
52307 26 52337 10 x0,34 91 .0
52308 7 X 0.14 4.0 6,6 25.0 26 52338 12 X 0,34 7.8 32,4 115.0
52309 8 X 0 ,14 4.3 7.9 27,0 26 52339 8.0 39,1 135.0
52310 4.3 9,2 30.0 26 52340 15 x0.34 9.0 49,1 154,0
52311 10 X0.14 4.6 10,3 38,0 26 52341 18 X 0,34 9,6 59,1
52312 12 X 0 ,1 4 5,4 13,2 45,0 26 52342 21 X0,34 180.0
52313 26 52343 25 X 0,34 10,1 68.3 233.0
5231 4 15 X 0.14 5.7 16.0 57.0 26 52344 272 .0
52315 18 X 0,14 6.2 20.1 65.0 26 52345 34 X 0,34 11.9 81.4
52316 6.7 23,7 76.0 26 52346 40x0,34 30,0
52317 21 X0,14 7 ,3 27.9 88,0 24 52347 13.3 111,1 36,0
52318 25 X 0 .14 7.9 33,4 98,0 24 52348 2x0.5 43,0
52319 30 X0 ,1 4 111 ,0 24 52349 3 X0,5 14.4 130.5 56,0
52320 34 X 0,14 8.1 39.3 24 52350 70,0
52321 8.9 45,5 139.0 24 52351 4 x0.5 4,6 9,5
52322 40 X0.14 9.5 53,6 764.0 24 52352 5 X0.5 101.0
52323 50 X 0.14 10,5 64,9 24 52353 7 x0.5 4,9 14.2 117.0
52324 18.0 24 52354 10x0.5 5.3 19,2 145,0
52430 2 x0.25 3.7 4.7 21,0 24 52355 12 X0.5 5,9 24.0 171,0
52431 3 X 0 .25 3,9 7,1 26,0 24 52356 15 X 0,5 6.4 33,7 197,0
52325 4X 0,25 4.2 9,5 24 52357 18 X0,5 230,0
52326 4.6 12,0 31.0 24 52358 8.4 48.0 269,0
52327 5 X0.25 5,1 16,6 40,0 24 52359 21 x0.5 8,6 57.4 301,0
52328 7 X0,25 56,0 22 52360 25 x0,5 9,8 72.0 365,0
52329 10 X0 ,25 6.4 24.0 64,0 22 52361 30x 0,5 10,5 86,4
6.5 28,6 40,0
12 x0.25 80.0 34 x0.5 11.1 101.0 51,0
15 X0.25 7.3 36.0 90,0 40x0.5 12.6 120,0
18 X0 ,25 7.8 43,2 2 X0,75 13,3 142.6 61.0
21 X0,25 8,3 50.4 105.0 3 X0.75 76.0
25 X0,25 9,3 59,8 121 ,0 4x0,75 14.5 163.1 97,0
34 X0 ,25 168,0 5 X0,75 137 .0
40 X0,25 10,8 81,3 196,0 7 x0,75 15.8 192.0 167.0
10 X0,75
2 X 0,34 11.7 96.0 25.0 12 X0.75 5,2 14,3
3 X0,34 4,3 6,4 30,0
5.5 21,5
4.5 9.7 6,0 28,6
6.7 36.1
7.3 50,3
9.8 72.0
10.0 86.2
Dimensions and specifications may be changed without prior notice. <RB01l
C HELUKABEL
~HI-TECH (800) 677-8942 I (303) 680-5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
TRONIC·CY (LiY-CY) flexible, cu-screened, colour coded to DIN 47100, ~
MEOI
EMC-preferred type, meter marking
HELUKABEL TRONIC-CY (LIY-CY) CSX0,2S QMM /20083 001042052 CE
RoH~
Technical data Cable structure Properties
• Special PVC data screened cables, adapted • Bare copper, fine wire conductors for • Extensively oil resistant. oil -/ chemical
to DIN VDE 0,5 mm2 to DIN VDE 0295 cl. 5 and Resistance - see table Technical
0812 IEC 60228 cl. 5 Informations
• Temperature range • Conductor make-up for • PVC self-extinguishing and flame retardant
flexing -5 oc to +80 oc 0,14 mm2 = 18x0,1 mm according to VDE 0482-332-1-2, DIN EN
0,25 mm2 = 14x0,15 mm 60332-1-2/ IEC 60332 -1 (equivalent
fixed installation -40 oc to +80 oc 0,34 mm2 = 7x0.25 mm DIN VDE 0472 part 804 test method Bl
• Nominal voltage
• Special PVC core insulation Tl2, to • The materials used in manufacture are
0,14 mm2 =350 v DIN VDE 0281 part 1 cadmium -free and contain no silicone and
;:: 0.25 mm2 = 500 v free from substances harmful to the
• cores stranded in layers with optimal wetting properties of lacquers
• Test voltage lay-length
core/core 1200 V Note
• Colour coded to DIN 47100, but w ithout
core/screen 800 v colour reoetition • HELUKABEL®-TRONIC-CY is also available in
paired version
• Breakdown voltage min. 2400 V • Core wrapping w ith foil (e.g. HELUKABEL®- PAAR-TRONIC-CY
16x2x0,14 mm2l.
• Insulation resistance • Drain-wire. tinned
min. 200 MOhm x km • Tinned, copper braided screen , approx. • For 1 core cable screen of helically wound .
• unscreened analogue type:
• Capacitance Capprox.-value>at 800Hz 85% coverage
• Special PVC outer sheath TM2, to TRONIC lliYY), see page B 4
core/core at 0,14 mm2=120 pF/m
DIN VDE 0281 part 1
core/core <:0,25 mm2= 150 pF/m • Colour grey CRAL 7001 >
core/screen at 0,14 mm2=240 pF/m • with meter marking, change-over in 2011
core/screen <: 0,25 mm2 =270 pF/m
• Load CAl According to different
cross-sections, see table
Technical Information
• Inductance approx. 0,65 mH/km
• Impedance approx. 78 Ohm
• coupling resistance max. 250 Ohm/km
• Minimum bending radius
flexing 10x cable 0
fixed installation 5x cable 0
• Radiation resistance
up to 80x106cJ/kg cup to 80 Mradl
Application
These screened cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet
rooms but not suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is t he suitable
cable to use. This applies especially to such areas as tool making and machine industries as well as electronic, computer, measurement and
control sectors.
The extremely small outer diameter make suitable for miniature plugs etc.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
<E= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.cores x o uter 0 Cop. Weight AWC·No. Part no. No.cores x outer 0 Cop. Weight AWC·NO.
cross-sec. approx. cross-sec. approx.
20139 mm• approx. mm weight kgtkm 26 20015 mm• approx. mm weight kgt km 26
20001 26 20091 kg/ km 26
20002 1 X 0.14 kg/km 16.0 26 20016 24 X 0 ,1 4 1 31 .0 26
20003 2 X0 ,14 20,0 26 20017 25 X0,14 8.3 62.0 136.0 26
20004 3 X 0 ,14 2.5 6.1 27 ,0 26 20018 27 X 0.14 142.0 26
20005 4 X 0 ,14 3.7 12,0 32,0 26 20019 30 X0.14 8.5 61 .0 157,0 26
20006 5 X 0,14 3 7.0 26 20020 32 X 0.14 163,0 26
20007 6 X 0 ,14 3.9 13,0 26 20021 36 X 0,14 8.5 65.0 182.0 26
20008 7 X 0 ,14 4,1 14,5 42.0 26 20022 40 X 0,14 9,3 69.0 209,0 26
20009 8 X 0 ,14 4,4 15.5 48.0 26 20023 42 X0 ,14 9,6 76,0 217,0 26
20010 10 X 0.14 4,9 18.2 55,0 26 20024 44 X 0 ,1 4 226.0 26
20011 12 X0 ,14 4,9 19.0 26 20025 48 X0,14 9,9 83.0 240,0 26
2001 2 14 X 0,14 65.0 26 20026 52 X 0.14 10,2 88.0 270,0 26
20013 16 X 0 ,14 5,2 21,3 77 ,0 26 20027 56 X0.14 10,5 94.0 320,0 26
20014 18 X 0,14 79,0 26 20028 61 X 0.14 11.2 110.0 370,0 26
20 X 0,14 6.2 28,7 89,0 80 X 0,14 510,0
21 X 0 ,14 6.2 30,5 103,0 100 X 0 ,14 11,3 115.0 Contin uation ~
116.0 580.0
6.6 32.0 120.0 11,8 124.0
6.9 43,2
7 ,2 51,0 12.1 132.0
7,7 55,0 12.4 146,0
14,1 226.0
7 ,9 56.0 15,6 267.0
c HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
TRONIC·CY (LiY·CY) flexible, cu-screened, colour coded to DIN 47100, ~
MEOI
EMC-preferred type, meter marking
Part no. No.cores x outer" Cop. Weight AWG·NO. Part no. No.cores x Outer fJ Cop. Weight AWG·NO.
cross-sec. approx. mm weight approx. cross-sec. approx.
20084 mm• kg/ km 24 16012 approx. mm weight kg/ km 20
20029 kg/km 16013 20
20030 1 X0.25 27.0 24 16526 kg/ km 210,0 20
20031 2 X0,25 2.9 7.2 31,0 24 16014 217,0 20
3 X 0.25 4,2 15,8 36,0 24 16015 10.6 129,0 246,0 20
20032 4 x0,25 4,3 18.6 40,0 24 16016 275,0 20
20083 5 X0,25 4,7 22.0 24 16527 10,7 152.0 337,0 20
20033 5,3 26,5 51.0 24 16017 351,0 20
20034 6 X0.25 5,7 32,4 58,0 24 16018 11 .2 156,0 20
20035 7 X0.25 5,7 35,0 64,0 24 16164 373.0 20
20036 6,3 42,1 82,0 16019 11,7 173,0 396,0 20
20037 8 x0.25 85,0 24 16528 431,0 20
10 X0.25 7.2 49.9 90,0 24 16020 12.6 236,0 440,0 20
20038 12 X0,25 7,3 58,0 144,0 24 16021 445,0 20
20039 14 X 0,25 7,9 62,0 110,0 24 16022 12.7 250.0 458,0 20
20086 16 X0,25 8,3 67,0 142.0 24 16023 470,0 20
20040 18 X0,25 9,1 78.0 146,0 24 16024 12,7 265,0 570,0 20
20041 19 X0,25 9,1 79,0 152,0 24 18
20042 20 X0,25 9,4 88,0 150,0 24 16025 14,1 297,0 650.0 18
21 X0,25 9,4 91,0 163,0 16026 780,0 18
20092 24 X 0.25 10,0 96.0 169,0 24 16027 14.6 301.0 990,0 18
20043 25 X0,25 10,1 99,0 176,0 24 16028 41,0 18
20044 27 X 0,25 10,1 122,0 189,0 24 16029 15,3 312,0 59,0 18
20045 30 X0,25 11,1 132,0 204,0 24 16030 18
20046 32 X0,25 11,5 138.0 219,0 24 16031 15,3 320,0 66,0 18
20087 36 X0,25 11,9 146,0 230,0 24 16032 77.0 18
20047 37 X0,25 11,9 152,0 247,0 24 16033 15,3 325.0 93,0 18
20048 40 X0,25 12,4 157,0 269,0 24 16034 113,0 18
20049 42 X 0.25 12,8 160.0 292,0 16035 15,8 345.0 18
44 X0,25 13,6 164,0 317,0 24 16036 130,0 18
20050 48 X 0,25 13,7 164,0 330,0 24 16037 18,1 407,0 145,0 18
20051 52 X0,25 14,1 175,0 343.0 24 16529 180,0 18
56 X0,25 14,5 189.0 365,0 24 16038 19,1 508.0 202,0 18
20052 61 X0,25 15,1 204,0 480,0 24 16039 18
20053 80 X0,25 17,1 387,0 605,0 24 16040 21,9 690,0 225,0 18
20054 100 X0,25 19,1 505,0 24,0 24 16041 275,0 18
1 X 0,34 3,2 13.5 16042 24.3 814,0 18
20055 5,0 18,0 30.0 22 16043 292,0 18
20088 2 x0.34 5,2 22,0 37,0 22 16163 3.8 19.0 322,0 18
20056 3 X 0,34 22 16044 362,0 18
20057 4 X 0,34 5,6 28.0 48,0 22 16530 5,8 38,0 435,0 18
20058 5 X 0,34 6.0 31,0 54.0 22 16045 415,0 18
20059 6,7 45.0 61,0 22 6.3 50,0 467,0 18
20085 6 X 0,34 6,7 51 ,0 67,0 22 16120 486,0 18
20060 7 X 0,34 7,2 54.0 22 16047 6,8 57,0 530,0 18
20061 8,4 65,0 81,0 22 16048
20062 8 X 0,34 8,5 70,0 103,0 22 16049 7,3 70.0 570,0 17
20063 10 X 0,34 9,0 81 ,0 22 16475 600,0 17
20064 12 X 0,34 110.0 22 16476 8,1 87,0 17
20065 14 X0 ,34 9,6 88.0 1 5 3,0 22 16477 640,0
20066 10,1 103,0 22 16478 8,2 96.0 680,0 17
20089 16 X 0 ,34 159.0 22 16479 714,0 17
20067 18 X 0,34 10,1 106.0 172.0 22 16480 9,0 110,0 900,0 17
20068 10,7 112,0 181,0 22 1200,0
20069 19 X0,34 191 ,0 22 16481 10,3 140.0 1440,0 17
20093 20 X0.34 10.7 116.0 199,0 22 16482 17
20070 21 X0,34 11,3 129.0 229,0 22 16483 10,5 151,0 65,0
20071 24 X 0,34 11,5 120,0 22 16484 80,0 17
20072 11,5 138,0 241,0 22 16485 11.3 167.0 98,0 17
20073 25 X0,34 12,6 158,0 258,0 22 16486 127,0 17
20090 27 X0 ,34 13.0 163,0 22 16487 11,8 183,0 144,0
20074 13,7 178.0 290,0 22 16488 158,0 17
20075 30 X0 ,34 13.7 192,0 305.0 22 16489 12,6 207,0 197,0 17
20076 32 X0 ,34 14,2 198.0 330,0 22 232,0 17
20077 14.8 203.0 348.0 22 16500 12,6 221.0 260,0
20078 36 X0,34 15, 4 214,0 364.0 22 16501 302,0 17
20079 37 X 0.34 15,6 227 ,0 389,0 22 16502 13,4 238.0 346,0 16
20080 40 X0.34 16,2 242 .0 22 16503 412,0 16
20081 42 X0,34 16,6 267,0 414.0 22 16504 14,1 270,0 493,0 16
20082 420,0 16505 562,0 16
44 X0,34 17,1 295.0 20 16506 14,3 278.0 790,0 16
16001 48 X0 ,34 19,4 524,0 450.0 20 16507 16
16002 480.0 20 16508 14,3 287,0 88.0 16
16003 52 X 0 ,34 21.7 620.0 520,0 20 16509 100,0 16
16004 56 X0,34 3,6 15,0 580,0 20 16510 15,8 315.0 126.0 16
16005 5,5 29,0 20 16511 16
61 X0,34 5,7 39,0 694,0 20 16512 16,3 330,0 160.0 16
16006 80 X 0.34 6,3 46.0 40,0 20 16513 192.0 16
16007 100 X0,34 6.8 52,0 45,0 20 16514 17,1 350,0 16
16008 7,3 66,0 55,0 20 208.0 16
16009 1 X0,5 7,3 68,0 61,0 20 17,1 370,0 244,0 16
16010 2 X0 ,5 8,0 80,0 315,0
16011 3 X0,5 9,4 93.0 76.0 17.9 386.0
9,6 117,0 89,0 338.0
4 x0.5 10,1 122,0 98,0 17.9 395.0 383,0
5 X0 ,5 117,0 424,0
6x0,5 18,4 408.0 506,0
7 X 0,5 135.0
8x0,5 157,0 21,5 555,0 690.0
10 X0,5 781,0
12 X0,5 190.0 24.6 715.0 941,0
14 X0,5
27,2 910,0
6,4 46,0
6,7 56,0
7,2 69,0
8,0 89,0
8,6 105,0
8,6 111,0
9.4 130.0
11,2 140,0
11,4 168,0
12,0 198,0
12,8 218,0
13,6 268.0
15,2 320,0
15,4 360,0
18,3 485,0
7,3 63.0
7,6 76.0
8.3 98.0
9.2 116,0
9.9 140,0
9,9 152,0
10,8 172,0
13,0 193,0
13,0 254,0
13,9 272,0
14,9 285.0
15,6 387,0
17,7 448.0
17,9 506,0
21,2 682.0
Dimensions and specifications may be changed w ithout prior notice. <RB01l
C HELUKABEL
~HI-TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
~ CONTROLS, INC.
PAAR·TRONIC·CY flexible, cu-screened, colour coded to DIN 47100, ~
MEOI
EMC·preferred type, meter marking
HELUKA8EL PAAA·TAONIC-CY 6x2x0.2SOMM/21038 001002304 CE
RoH~
Technical data Cable structure Properties
• Special PVC data cables. adapted to • Bare copper, fine wire conductors, bunch • Extensively oil resistant. oil·/ chemical
DIN VDE OB12, OB14 stranded to DIN VDE 0295 cl. 5, 0245 and Resistance · see table Technical
IEC 6022B cl. 5 Informations
• Temperature range
• Conductor make-up for • PVC self-extinguishing and flame retardant
f lexing · 5 •c to +80 •c according to VDE 04B2-332·1·2, DIN EN
f ixed installation · 30 •c to +BO •c 0,14 mm2= 1Bx0,1 mm 60332·1 ·2/IEC 60332·1 <equivalent
• Operating voltage 350 v DIN VDE 0472 part 804 test method Bl
0,25 mm2 = 14x0,15 mm
<not for purposes of high current and 0,34 mm2 = 7x0,25 mm • The materials used in manufacture are
power installation> • Special PVC core insulation Yl2, to cadmium-free and contain no silicone and
• Test voltage DIN VDE 0207 part 4 free from substances harmful to the
• Colours coded to DIN 47100 with colour wetting properties of lacquers
core/core 1200 v repetition
• Cores stranded in pairs with optimal Note
core/screen BOO V lay -le n g th
• Breakdown voltage min. 2400 V • Also available in other sheath colours.
• Pairs stranded in layers with optimal • unscreened analogue type:
• Insulation resistance lay -le n g th
min. 20 MOhm x km PAAR·TRONIC, see page 8 6
• Core wrapping with foil
• conductor resistance • Tinned copper braided screening, coverage
at 0,14 mm2 s 13B Ohm/km
at 0,25 mm2 s 75,5 Ohm/km approx. B5%
at 0,34 mm2 s 57,5 Ohm/km • Special PVC outer sheath YM2. to
at 0,50 mm2 s 39 Ohm/km DIN VDE 0207 part 5
at 0,75 mm2 s 26 Ohm/km
• Sheath colour grey IRAL 7032>
• capacitance <approx.-valuel at BOO Hz • with meter marking, change-over in 201 1
core/core 0,14 mm2 =120 pF/m
core/core2:0,25 mm2 =150 pF/m
core/screen 0,14 mm2 = 240 pF/m
core/screen 2:0,25 mm2 = 270 pF/m
• Load
at0,14 mm2 =1,5 A
at 0,25 mm2 = 2,5 A
at 0,34 mm2 =4,5 A
at 0,50 mm2 = 6 A
at0,75 mm2= 9 A
• Inductance approx. 0,65 mH/km
• Impedance approx. 7B Ohm
• K1·coupling approx. 300 pF/100 m
• coupling resistance
max.250 Ohm/km
• Minimum bending radius
f lexing 10x cable 0
f ixed installation 5x cable 0
• Radiation resistance
up to 80x106 cJ/kg lup to 80 Mradl
Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet
rooms but not suitable for open air.
PAAR·TRONIC·CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially the effects
of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an "earth".
The twisted pairs conform favourable cross-talk attenuation values. These cables are suitable for dry and wet rooms. yet not for open air.
EMC = Electromagnetic compatibillity
C€= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part no. No.paln; x Outer 0 Cop. Weight AWG•No. Part no. No.paln; X Outer 0 Cop. Weight AWG•No.
cross-sec. approx. cross-sec. approx.
21001 mm• approx. mm w eight kg / km 26 21006 mm• approx. mm weight kg 1 km 26
21002 26 21007 26
21003 1X 2X 0,1 4 kg /km 34,0 26 21008 6x2x0.14 kg / km 86,0 26
21004 40,0 26 21009 7 x2x 0.14 91,0 26
21005 2x2x0.14 4.1 15,6 49,0 26 21010 8x2x0.14 7.2 48,5 97,0 26
3x2x0.14 55,0 10x2 x 0.14 109,0
4x2 x0.14 5,6 18,5 12x2x0.14 7.2 51 .1 141,0 Continuation •
5x2 x0.14 66.0
5,6 23,0 8,4 53.7
6,0 26.6 9,1 59.0
6.7 30.7 9,2 66,0
c HELUKABEL
HI·TECH (800) 677·8942 I (303) 680·5159 www. hitechcontrols.com
Click or Call for a Quotel
@ CONTROLS1 INC.
PAAR·TRONIC·CY flexible. cu-screened, colour coded to DIN 47100, ~
MEOI
EMC·preferred type, meter marking
Part no. No.palrs x Outer" Cop. Weight AWG·NO. Part no. No.palrs x Outer" Cop. Weight AWG·No.
cross-sec. approx. cross-sec.
21011 mm• approx. mm weight kg 1 km 26 19972 mm• approx. mm weight approx.
21012 14 X2 X0.14 26 19973 kg I km
21013 15 x 2 x0.14 kg 1 km 148,0 26 19974 3 X2 X0,34 kg 1 km
21014 16x2x0.14 152,0 26 19975 4 X2 X0,34
21015 18x2x0,14 9,9 74,0 155,0 26 19976 5 X2 X0,34 7,3 44,9 78.0
21016 20x2x0,14 26 19977 6 X2 X0,34
21017 22 X2 X0,14 10,4 76,0 171.0 26 19978 7 X2 X0,34 8,1 54.2 90.0
21018 24 x 2 x0,14 183,0 26 19979 8 X2 X0,34 110.0
21019 25x2x0.14 10,4 79.0 205,0 26 19980 9 X2 X0,34 8.8 63.5
21020 26x2x0,14 26 19981 10 X2 X0,34
21021 27x2x0.14 11,0 83,0 228.0 26 19982 12 X2 X0,34 9.8 73,1 130.0
21022 28 X2 X0,14 239.0 26 19983 14 X2 X0,34 145.0
21023 30x2x0,14 11,5 97.0 245,0 26 19984 16 X2 X0,34 9,8 79,5 150.0
21024 32 X2 X0,14 251,0 26 19985 18 X2 X0,34 170.0
21025 34 x 2 x0.14 12,3 103,0 258,0 26 19986 21 X2 X0.34 11,2 88,4 190,0
21026 36x2x0,14 26 19987 25 X2 X0,34
21027 38x2x0.14 12.3 111,0 270.0 26 19988 27 X2 X0,34 12,6 99,3
21028 40x2x0.14 284,0 26 19989 30 X2 X0,34
21029 44x2x0.14 12,5 113,0 300,0 26 19990 34 X2 X0,34 12,6 106,9
21030 46 X2 X0,14 316,0 26 19991 37 X2 X0,34
21031 50x2x0.14 12,5 122.0 26 19992 40 X2 X0,34 12.8 122.1 220.0
21032 52 X2 X0,14 350.0 26 19993 44 X2 X0,34 245.0
21033 55 x 2 x0,14 12,5 125.0 370.0 24 19994 50 X2 X0.34 13,3 138,2 250.0
21034 390,0 24 19995 52 X2 X0,34 275.0
21035 1 X2 X0,25 13,7 128,0 430.0 24 17047 56 X2 X0,34 14,3 154.2 300.0
21036 2 x 2 x0.25 24 17001 61 X2 X0,34 400.0
21037 3 X 2 X 0,25 13.7 140,0 440.0 24 17002 15,2 197,9 410.0
21038 460,0 24 17003 1 X 2 X0.5 440,0
21039 4 X 2 X0,25 14.2 145,0 480,0 24 17004 2 X2 X0.5 15.9 214,4
21040 5 X 2 X0,25 24 17005 3 X2 X0,5
21041 6 x2 x0,25 14,7 150,0 45,0 24 17006 4 x 2 X0,5 17,5 238.5
21042 7 X 2 X0,25 53.0 24 17007 5 X2 X0,5
21043 8 X2 X0,25 14,9 156,0 65,0 24 17008 6 X2 X0,5 17,5 262.5
21044 10 X2 X0,25 24 17009 8 X2 X0,5
21045 12 x2x0,25 15.6 162,0 80,0 24 17010 19,1 286, 6
21046 14x2 x0.25 98,0 24 17011 10 X 2 X0.5
21047 15x2x0,25 16,1 177.0 114,0 24 17048 12x2x0.5 20,8 310,1 510.0
21048 16 X2 X 0,25 121,0 24 17012 16x2 x0.5 550.0
21049 16.8 181.0 24 17013 20 X 2 X 0,5 21,5 368.7 590.0
21050 18x 2 x0.25 129,0 24 17014 25 X2 X0,5 600.0
21051 20x 2 x0,25 17.0 195.0 157,0 24 17015 22.4 392.6 650.0
21052 22 X2 X0,25 24 17016 1 X2 X0.75 680.0
21053 24 X2 X0,25 17.7 202.0 189.0 24 17017 2 X2 X0,75 23.6 424.3 750.0
21054 25 x2 x0.25 213.0 24 17018 3 X2 X0,75 840,0
21055 26 X 2 X 0,25 17,7 206,0 225.0 24 17019 4 X2 X0,75 24,8 455,9 60,0
21056 237,0 24 17020
21057 27 X 2 X0,25 18,2 210,0 248.0 24 17021 5x2 x0.75 24.8 487.6
21058 28x 2 x0,25 275,0 24 17022 6 X2 X0,75
21059 4,6 15,0 303,0 24 17049 8 X2 X0,75 25.4 518.5
21060 30x 2 x0.25 330,0 24 17050 10 X2 X0,75
21061 32 x 2 x0.25 6,3 28,0 343.0 24 17051 12 X2 X0,75 26.2 557,2
21062 34 X2 X0,25 345.0 24 17052
21063 36 X2 X0,25 6.6 32,0 350.0 24 17053 16x2 x0.75 5,6 24,0
21064 38x 2 x0.25 360,0 24 17054 20 X2 X0,75
19970 40x 2 x 0,25 7.0 38.0 375,0 22 17055 7,8 54.0 89.0
19971 400,0 22 25 X2 X0.75 104,0
44 x2 x 0,25 7.8 55,0 ~7056 1x2x1 8,2 70,0
46 X2 X 0,25 410.0 2x2x1
SOX 2 X0,25 8,6 65,0 420,0 3x2x1 9 ,1 91.0 126.0
52 x 2 x0.25 450.0 4x2x1 148,0
55 X2 X0,25 8,6 70,0 485,0 9,9 105,0
1 X2 X0,34 1 X2 X1,5
2 X2 X 0,34 9,8 75,0 500.0 2 x2 x1.s 10,7 120.0 171.0
540,0 3x2x1.5 290.0
11,0 110,0 550,0 4X2X1.5 12.8 144.0 320.0
580,0 361 ,0
11.2 117,0 14,0 178.0 421.0
630,0 580.0
12.2 122,0 58,0 14,3 199,0 740,0
65,0
12.8 134,0 16.1 254,0 71,0
105,0
12,8 143,0 17,2 302,0
13.5 148,0 19,7 3440
14.1 162,0 6,0 28.0
14,9 172,0 8.4 58,0
15,3 223,0 8,9 84,0 128.0
156,0
15.5 233,0 9,8 108,0
15,5 238,0 10,8 126.0 189.0
15.5 244,0 12.1 146.0 216.0
309,0
17,0 249,0 13.4 180.0
17,0 254,0 15.5 220.0 355.0
405,0
17.6 290,0 15.8 261,0
18,2 565,0
~12,0 18.0 328.0
18,2 322,0 19.2 392.0 700.0
950,0
19,0 339,0 21 ,8 470.0
--~
19.7 349,0 6.3 46.0
20.5 359,0 8.9 82.0 116.0
140,0
20,7 398,0 9,4 103.0 191.0
21.5 403,0 10.4 132.0 84,0
21 ,5 435.0 7.2 63.0
22,1 464,0 10.2 111.0 122.0
194,0
5.2 16,0 10,8 136,0
7.0 36,9 12,0 172.0 240.0
Dimensions and specifications may be changed without prior notice . <RB01 l
C HELUKABEL