The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.

ACDC FULL MAIN CATALOGUE 2016.compressed

Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by monde, 2016-09-20 06:34:49

ACDC FULL MAIN CATALOGUE 2016.compressed

ACDC FULL MAIN CATALOGUE 2016.compressed

1 - 46 Timers, Process Control, Power Monitors, Liquid Level Controllers, Time Switches, AUTOMATION PRODUCTS
Counters, Relays & Bases and Solid State Relays LEVEL CONTROL & PUMPS
POWER SUPPLIES, TRANSFORMERS & UPS
47 - 72 Float Switches, Level Sensors, Flow Switches, Irrigation Controllers,
Pressure Switches, Swimming Pool Products and Pumps SOLAR
MOTOR CONTROL
73 - 97 Transformers, Variacs, Regulated Power Supplies, DC-DC Converters, CIRCUIT BREAKERS, FUSES & SWITCHGEAR
98 - 126 Batteries & Battery Chargers, UPS's, AVR's and Power Managers PUSHBUTTONS & PILOT LIGHTS
Solar Lighting Kits, Batteries & Solar Battery Chargers, Solar Panels, Charge Regulators, TERMINALS, INSULATORS & COPPER
On-Grid & Off-Grid Inverters and Home Systems SURGE & NOISE PROTECTION
INSTRUMENTS & TELEMETRY
127 - 150 Soft Starters, Variable Speed Drives, Motor Protection, Motor Starters CAPACITORS & PFCs
Contactors & Overloads TEMPERATURE CONTROLS
CRANE & VEHICLE CONTROLS
151 - 186 Ready Boards, Circuit Breakers (MCB & MCCB), Air Circuit Breakers, Isolators, LIMIT & PRESSURE SWITCHES & SENSORS
Change Over Switches & Fuse Protection AUDIO & VISUAL ALARMS

187 - 196 Pushbuttons, Pilot Lights, Legend Plates, Lamps, Enclosures AUTOMOTIVE
Rocker & Toggle Switches FLAMEPROOF & MINING
TEST INSTRUMENTS, TOOLS & GENSETS
197 - 214 Din Rail, Terminals, Terminal Blocks, Insulators, Busbars & Copper and Wire WIRING ACCESSORIES

215 - 223 Surge Protection Devices, Lightning Protection, Line Filters and MOV's ELECTRONICS
ENCLOSURES & FITTINGS
224 - 260 Panel Meters, Current Transformers, Network Analysers, Energy Meters, PLC's,
Telemetry Systems, Modbus Interfaces , Signal Isolators/Transmitters and Genset Controllers GEWISS
LIGHTING
261 - 265 Motor & Lighting Capacitors, Power Factor Controllers, Harmonic Filters, FANS, BUG KILLERS & HYGIENE
PFC Capacitors and Complete PFC Systems SECURITY
TECHNICAL INFORMATION
266 - 275 Thermostats, Temperature Controllers, Temperature Probes, Temperature &
Humidity Control, Refrigeration Controllers and Solar Water Heating Controllers © Copyright - ACDC Dynamics 2016

276 - 279 Wired Pendant Stations, Wireless Remote Crane Controls,
Worm Drive Limit Switches and DC Contactors

280 - 332 Solenoid Valves, Gauges, Pressure Transmitters, Pressure Switches, Limit Switches,
Proximity Sensors and Safety Systems

333 - 353 Speakers, PA Systems, Fire Protection, Sounders, Beacons, Sirens and Tower Lights

354 - 367 Traffic Lights, Light Bars, DC Worklights, LED & HID Auto Lamps, Solar Road Marking,
Aviation Obstacle Lights and Marine Navigation Lights

368 - 392 Robust & Explosion Proof Lighting, Enclosures, Limit Switches, Control Stations,
Starters, Gulley Boxes, Beacons & Sounders and Telephones

393 - 438 Two Way Radios, Test Instruments, Power Quality Analysers, Measuring Equipment &
Tools, Tool Boxes, Hand Tools, Power Tools, Welders and Generators

439 - 512 Sockets & Switches, Plug Tops & Adaptors, Extension Cords, Cable Connectors & Joints,
Cable Marking, Cable Routing Systems, Wiring Consumables Adhesives & Sprays

513 - 519 Terminals, Heatsinks, LED's, Rectifiers, Appliance Plugs & Sockets and
Multi-Pole Connectors

520 - 547 Panel Locks and Hinges, Safety Lockout, Stainless Steel, Mild Steel & Plastic Enclosures
& Distribution Boards, Kiosks, Meter Boxes and 19" Racks

548 - 609 Enclosures & Distribution Boards, Conduit, Lighting Isolators, IEC309 Plugs & Sockets,
Circuit Breakers, Chorus Sockets, Switches & Intercom Systems and Lighting

610 - 779 Highbays, Flood Lights, Street Lights, Domestic & Commercial Lighting, Decorative
Lighting. LED, CFL's, Discharge & Induction Light Sources

780 - 798 Ceiling Fans, Domestic & Industrial Fans, Extractor Fans, Heaters, Underfloor Heating,
Insect Killers, Hygiene Products, Instant Water Heaters, Taps and Water Dispensers

799 - 840 TV & Satellite Accessories, Intercoms & Access Control Systems, Alarm Systems,
Camera & Recording Systems, Gate Motors & Electric Fencing

841 - 847 Technical Information & Index
Specifications are subject to change from time to time, without notification in this publication.

TIMERS

Type Unequal Repeating Delay On Interval Equal Repeating Delay Off
Code & Two-Shot Timer DP1* DP2* DP3 No Power
IP1* IP2* IP3 EP1* EP2*
Outputs UP1/M UP2/M SPDT DDP1* DDP2* DDP3
Mode of UP1/MV UP2/MV SPDT DPDT +INST
Operation SPDT SPDT
SPDT DPDT SPDT DPDT +INST SPDT DPDT SPDT DPDT +INST

Multi range timer Upon application of the Upon application of the Upon application of the No power required delay
Time Ranges: supply voltage the delay supply voltage the relay supply voltage the relay off function. Upon
0.15s to 10s time period begins and the operates, the power and operates and the ON time application of the supply
1s to 60s power LED lights up. On relay LED lights up and period starts. After the ON voltage the relay
1.5s to 100s the expiry of the set time the time period begins. period has expired the operates. When the
10s to 10m the relay LED will light up On the expiry of the set relay releases and an supply voltage is
1m to 60m and the relay will operate time, the relay releases equal OFF time period disconnected the time
10m to 10hr and will not release until and will not operate again, starts. This equal operation period starts and at the
Selectable by DIP the supply voltage is until the supply is continues until the supply end of the time period the
switches 1, 2, 3 & 4 disconnected. re-applied. voltage is relay releases, the time is
at rear of timer. disconnected. reset and the relay
Timing functions: DP3: Output relay A is IP3: Output relay A is remains released until
Unequal repeating instantaneous. instantaneous. the supply voltage is
(off first) reapplied. For time ranges
Unequal repeating above 600 sec there is a
(on first) built-in battery.
Two-shot (off first)
Two-shot (on first) This timer is not to be
Selectable by DIP used for short pulses,
switches 5 & 6 at as battery requires
rear of timer. 24H to recharge.
Use IAP1or 2.
UP1/MV & UP2/MV:
Multivolt range
24-250VAC/DC

Connection
Diagram

AUTOMATION PRODUCTS Note: SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY
Standard VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE
stock is 11
Pin. 8 Pin 11 Pin SPDT 11 Pin DPDT 11 Pin SPDT+INST 8 Pin SPDT 8 Pin DPDT
available on A=Instantaneous
order
Contact
Supply AC
Multi-Volt Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% (Test volts 2kV)
Supply DC 24 - 250VAC/DC (available only on models marked *)
12, 24, 48VDC

Specification Range accuracy: ±5% Power consumption AC: 1.5VA
100mA @ 12VDC
Repeatability: 1% DC: 10A 250VAC
5A 250VAC
Scale accuracy: ±5% Contact rating SPDT:

Reset time: 300mSec DPDT:

Operating temperature: -20 to 70°C For external potentiometer: use 1MΩ

1 M1 See Page 6 for Time Ranges

TIMERS

Multi-Range Dual Timers Forward Reverse Percentage Timer Delay on Pulse Start Interval Pulse Start
Multi-Function Timer (Multi-Range)

MFMR MFMRV DP/DP DP/IP WM1/M PP1 DAP1 DAP2 IAP1* IAP2*

DPDT 2 x SPDT 2 x SPDT SPDT SPDT SPDT DPDT SPDT DPDT

Time Ranges: OUTSTANDING Function: When the power Upon application of the Start switch between Start switch between
0.02 to 1s; 0.15 to 10s VALUE, TWO TIMERS is applied the contact supply voltage the OFF 5 & 7: Apply supply 5 & 7: Apply supply
1s to 60s; 10s to 600s IN ONE! between 1 & 4 closes. The time starts. At the end of voltage. Upon the voltage. Upon the
1m to 60m; 10m to 10h contact remains closed for the OFF time the relay closure of switch 5 & 7 closure of switch
22m to 24h; 3h45m to DP/DP an adjustable forward or ON operates and stays in the timing period starts, between 5 & 7 the relay
240h Two delay on timers time period. It then opens operation for the remaining irrespective of whether operates and the time
sharing common power for an adjustable pause or on time. Thereafter it the start switch is closed period starts. When the
Selectable by DIP supply. Independently OFF time period. After the returns to the OFF or not. After the set time set time has expired the
switches 1, 2 & 3 at rear adjustable. pause delay, contacts 1 & 3 position. ie. The total OFF the relay will operate. To relay releases
of timer. close and remain closed for and ON period is equal to repeat this function irrespective of whether
DP/IP a reverse or ON time (same the full time. This recycling supply voltage must be the start switch is still
Functions: One delay on timer and as the forward time). After operation will continue until removed and re-applied closed or not.
Delay on (DP2) interval timer sharing the reverse period the the supply voltage is again.
Delay on pulse start common power supply. contact between 1 & 3 removed. Start switch between
(DAP2) Independently opens for the pause time. Start switch between 6 & 7: Apply supply
Interval timer (IP2) adjustable. This cycle is repeated until 6 & 7: Apply supply voltage. Upon closure
Interval timer pulse start supply is removed. voltage. Upon closure of of start switch between
(IAP2) switch 6 & 7 nothing 6 & 7 the relay
Equal repeating timer DIP Switches 1 to 5: happens. The timing operates. The time
(EP2) OFF first On Pause & Time Ranges: period will only start period ONLY STARTS
Equal repeating timer 0.15s to 10s 1.5s to 100s when the switch between from the break of the
(EP2) ON first 1s to 1m 10s to 10m 6 & 7 has opened, upon switch.
10s to 10m 100s to 100m opening the timing period
Selectable by DIP 1m to 1h 10m to 10h begins. After the set time
switches 4 & 5 at rear of the relay will operate.
timer. DIP switch 6: OFF. Pause
period first. ON: on period
MFMRV: Multivolt supply first. External POT 100K
24-250VAC/DC

External POT 100K

SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY AUTOMATION PRODUCTS
VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE

SPDT DPDT

Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% (Test volts 2kV)
Multivolt 24-250VAC/DC (available only on models marked*).
12, 24, 48VDC

Specification Range accuracy: ±5% Power consumption AC: 1.5VA
100mA @ 12VDC
Repeatability: 1% DC: 10A 250VAC
5A 250VAC
Scale accuracy: ±5% Contact rating SPDT:

Reset time: 300mSec DPDT:

Operating temperature: -20 to 70°C For external potentiometer: use 1MΩ

See Page 6 for Time Ranges M1 2

TIMERS

Type Star-Delta Timer One-shot Timer Triac Flasher Relay Flasher Defrost Timer Repeating Pulse

Code SDP1 OSP1 OSP2 TFP1 TFP2 RFP1 RFP1/A DET1 DET1/F RP1
Outputs
Operation Mode SPDT SPDT DPDT Triac Output SPDT WITHOUT WITH SPDT
FAN FAN
Connection When supply voltage LINK:5-6: Pulse on TFP1 (230VAC only) RFP1 DELAY DELAY Upon application of
Diagram is applied c­ onnection energisation Upon applying the On applying the the supply voltage
between Pin 1 & Pin 4 LINK 6-7: Pulse on supply the lamp will supply, the lamp will Upon application of the delay period
is made. The time de-energisation. flash with an equal flash with a fixed supply voltage, begins. On expiry of
period starts for Star When the power is on and off time until equal on and off time cooling cycle starts, the set time, the
connection. After the applied the relay the supply is of 0.5 sec. This will (4, 6, 8 or 12 hrs) relay pulses on for
Star set time has operates for 0.5 sec. removed. This on continue until the followed by defrost 0.5 sec and a new
elapsed When power is and off time is supply is removed. cycle (1-60min). time period begins.
connection between de-energised the relay adjustable from 0.02 Can be used to LINK 5-6: As above This repeating pulse
Pin 1 & 4 is opened operates for 0.5 sec. - 1 sec. switch one lamp or except defrost cycle continues until the
and stays in a n­ eutral two alternating lamp starts first. supply voltage is
position for 100mS. TFP2 (230VAC only) circuits. DET1/F: Is for freezer disconnected.
After the 100mS Upon applying the rooms and has
pause ­connection is supply, lamp 1 will RFP1/A additional relay for
made between pin 1 & switch on then As per RFP1 except fan delay (6-360
3 for the Delta switch off and then that the equal on and Sec).
contactor. lamp 2 will switch off time is adjustable LEDs “defrost on”
on. This on and off from 0.02 to 3 sec. “fan on”.
time is adjustable Dip switch selection:
from 0.02 - 1 sec.
cycle times
Triac: 1000W (4A) 4 hour
@ 250VAC
6 hour

8 hour

12 hour

OSP1 TFP1 C:COOLING
D:DEFROST
F:FAN

RFP1 & /A TEMP
OVERRIDE

SUPPLY
VOLTAGE

AUTOMATION PRODUCTS OSP2

TFP2

SUPPLY SUPPLY TEMP SUPPLY
VOLTAGE VOLTAGE OVERRIDE VOLTAGE

SUPPLY
VOLTAGE

SUPPLY
VOLTAGE

Supply AC Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% (Test volts 2kV)
Supply DC
Specification Output Rating: SPDT: 10A @ 250VAC 12, 24, 48VDC
DPDT: 5A @ 250VAC
3 Triac: 1000W (4A) @ 250VAC Power Consumption: AC 1.5VA
DC 100mA @ 12VDC

M1 See Page 6 for Time Ranges

PROCESS CONTROLS

FADIELSSIAGFNE

Type Alarm Relay Thermistor Relay Single & Dual Differential Relay Signal Converter
Code 3I/P / 3O/P Alarm Relay
Outputs
Mode of AL3 TH1 SAR1 DAR2 DIR DIRV SIC1† SIC2†
Operation SPDT SIC1† SIC2†
4 x SPST SPDT SPDT DPDT
Connection 4-20mA 0-10V
Diagram
On closing of any input The relay is normally SAR1: Single trip point This module provides a The Signal Converter
contact, the energised, when one of DAR2: Two trip point relay output with high ­modules convert various
corresponding output the thermistors reaches (2 relay outputs and low set points from input signals to a 4-20mA
relay and hooter will tripping ­temperature the independently adjustable) an ­analogue instrument­ or 0-10V DC signal. They
e­ nergise. By using a relay de-energises. The signal.­ are intended for use with all
common flasher ­connect relay will energise when The relay is normally PLC and other
to Pin 11 lamp 1 will the temperature drops to de-energised and will The output relay will instrumentation­ systems.
flash. By pressing the below trip level. energise when the input energise on the high set †Input selection
accept button the lamp signal reaches the set point and de-energise A: 0-5 Amps AC/DC
will steady and remain Latch facility level, set by a on the low setpoint B: 0-1 Amps AC/DC
on until the fault is Link Pins 7-9. Relay potentiometer. The relay offering a wide R: Ohms
removed, and the hooter remains de-energised will de-energise when the adjustable differential­. V: Voltage range AC/DC
will stop. More alarms after tripping. input signal drops below Calibration: For field
can be added by merely To reset, break supply the set level by 3% When more than one calibration, energise module
­commoning up more voltage or operate N/C unit is used in series and set input to maximum.
modules with no external reset device The second alarm relay and the supply is DC, Adjust SPAN until output­is
restriction. Pins to be connected to Pins 7-9. operates the same but set an isolator must be 20mA/10V. Set input to
common when at a different trip level. used for each unit: minimum­requirement and
expanding; 11,10, 9, 7 ISO-12VDC adjust ZERO until output is
and common of hooter. ISO-24VDC 4mA/0V. Calibration is
complete.
Red LED: Power on.

INPUT INPUT
LINK 6 & 7 LINK 6 & 7
0 -20 mA 0 - 5VDC
NO LINK 6 & 7 NO LINK 6 & 7
4 - 20 mA 1 - 5VDC

SUPPLY SUPPLY SUPPLY SUPPLY AUTOMATION PRODUCTS
VOLTAGE VOLTAGE VOLTAGE VOLTAGE

Specification Lamp test Pin 7 Tripping resistance Input signal: Input signal: Inputs:
Alarm accept Pin 9 1.2kΩ 4 - 20mA SIC*A: 0-5 Amps, AC/DC
Power Hooter Pin 8 No. of thermistors to be 0 - 20mA }4 - 20mA DIR SIC*B: 0-1 Amps, AC/DC
Consumption To be utilised with connected in series not or SIC*R: 1-20kΩ
Supply AC relay flasher RFP1 to to exceed 1kΩ 0 - 5VDC 0 - 20mA SIC*V 10V: 0-10V, AC/DC
Supply DC Pin 11 1 - 5VDC SIC*V 150V: 0-150V, AC/DC
Contact Rating or SIC*V 300V: 0-300V, AC/DC
DC: 600mA SIC*V 600V: 0-600V, AC/DC
@12VDC }0 - 5VDC DIRV * 1: for 4-20mA. 2: 0-10V output

Not Available 1 - 5VDC

12, 24VDC AC ± 1.5VA

Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% (Test volts 2kV)

SPDT: 10A @ 250VAC 12, 24, 48VDC
DPDT: 5A @ 250VAC

M1 4

PROCESS CONTROLS

FADIELSSIAGFNE FADIELSSIAGFNE

Type Namur Sensor Pivot Shut Centre Pivot Three Start Pulse Counter Signal Isolator
Relay Down Relay Shut Down Attempt Relay (Transducer)
Code
Outputs NS1 VCT1 EVCT1 TSAP1 CO1 Input Output Code
Mode of
Operation SPDT SPDT SPDT Start: SPDT SPDT 4-20mA 4-20mA SI-1A
Alarm: SPDT
The Namur sensor For use with centre Popular VCT1 11 Pin
relay converts the pivot irrigation Plug in module Upon application of When the supply 4-20mA 0-10V SI-1A/V
changing current of systems to prevent mounted in an easy the supply voltage,
an Inductive or overwatering of the connect box. the ‘start’ relay voltage is applied
Capacitive Namur field. Add on kit to the operates for a set
sensor into a relay On application of existing centre pivot ‘on’ duration the relay remains All outputs are
switching. The ­voltage, the output control panel to followed by a set
sensor can be relay energises for prevent overwatering ‘dwell’ cycle. After OFF. galvanically isolated from
connected between the adjustable start should the pivot arm the relay has
5 & 6 to energise up delay period. get stuck or the operated for the no. The Pulse count is inputs.
the relay when the Once running, if the percentage timer of starts as per the
sensor is activated, pivot arm motors do misfunction. dip switches and the incremented on
or between 6 & 7 to not draw a minimum Supplied with CT-5 supply voltage is still
energise the relay adjustable current with flying leads for present, the ‘alarm’ each closure Output: 4-20mA into
when the sensor is within an adjustable simple installation. relay will operate
deactivated. time (usually 3 and this condition (pulse) of switch 0-600 ohms load.
­minutes for 20% will prevail until the
See page 295 for watering), the supply voltage is 6-7.
Namur sensors. output contact removed.
de-energises, When the preset Isolation between IP/OP
switching off the
Pump Start circuit. number of pulses is and Mains = 600V

reached the relay

switches on.

At the next closure

of switch 6-7 the

relay is reset and

the count cycle

starts again.

Dip switch setting: No. of Pulses
3-6 starts 4 Link 9-11
Start time: 0.5- 5 Link 5-11
30sec adjustable. 6 No link

Connection
Diagram

AUTOMATION PRODUCTS SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY
VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE

Specification Sensor current: 8mA For use with DIN type CT-5 current Supply Voltage: 1.5VA
Open voltage: 8.5V transformer (see page 166) 9-30VDC s­ tandard –
(Input 0-4V) Other Voltages
available

Power AC: ±1.5VA DC: 100mA @ 12VDC
Consumption Galvanic isolation with internal transformer 24, 48, 115, 230, 400, 525VAC ±15% (Isolation test volts 2kV)
Supply AC ––
Supply DC
Contact Rating SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC

5 MM11

FADIELSSIAGFNE PROCESS CONTROLS ACCESSORIES

For Plug-In Modules

RC BC

Coincidence Over/Under Speed Temperature Relay Temperature Relay Accessories Code
Relay A1024BK
& Tacho Relay for T/C: J & K for T/C: PT100 Timer box - Black RC
Retaining clip BC
CS1 TM1 TM4 TRJ2 TRJ4 SPDT -20 to +80°C TR1 11 Pin base cover POT 1MEG
TM4/R TRK2 TRK4 Remote pot. 1MΩ POT 10K
Remote pot. 10kΩ
SPDT SPDT SPDT 0 to 100°C TR2
SPDT SPDT

External contacts A and B The Tacho relay connects to 0 to 0 to SPDT +50 to 150°C TR3
typically are pushbuttons a PNP,NPN or Namur induc- 200°C 400°C SPDT +50 to 200°C TR4

mounted 1m + apart on a tive or capacitive sensor TRJ2 & TRJ4 for Link 8 & 9: (under temp)
The temperature relay
press or guillotine. Under Speed: Link 5 & 11 J type thermocouple

The operator must press The relay energises if input TRK2 & TRK4 for connects to a temperature
both buttons, keeping his K type thermocouple sensor PT100. The relay
hands safely away, before speed drops below the set energises when the
limit.

the machine operates. Over Speed: No link 5 & 11 The temperature relay temperature exceeds the set
Apply the supply voltage. The relay energises when the connects to a temperature limit. The relay de-energises
when the temperature drops
The contacts A & B must be speed exceeds the set limit sensor. The relay
below the set limit.
actuated within 0.5s in order DIP SW: SW1 ON: NPN energises when the

to make the relay operate. SW1 OFF: PNP temperature exceeds the NO Link 8 & 9: (over temp).
If one of the contacts is Output TM4: set limit. The relay The relay energ­ ises on
interrupted the relay will SW2 ON: 4-20mA de-energises when the application of power and will
immediately release. SW2 OFF: 0-20mA temperature drops below de-energise when the temp.
Ranges: the set limit. exceeds the set value.
Ideal for use in machine Posn RPM Posn RPM
safety guard systems. 1 2-20 6 100-1k Remote control available
2 5-50 7 200-2k on request.

3 10-100 8 500-5k AC Supply Only
4 20-200 9 1k-10k

5 50-500 10 2k-20k

PNP OR NPN

External dimensions (mm) A1024BK

Standard Time Ranges

SUPPLY SUPPLY SUPPLY SUPPLY 0.02 - 1 sec 0.05 - 30 min AUTOMATION PRODUCTS
VOLTAGE VOLTAGE VOLTAGE 0.05 - 3 sec 1 - 60 min
VOLTAGE 0.20 - 10 sec 2 - 120 min
Control: On/Off Overtemp: No link between 0.50 - 30 sec 3 - 180 min
TM1 - 1mA Output Proportional on request Pins 8 & 9 1 - 60 sec 0.08 - 5 hours
TM4 - 4-20mA Output Latch: Pin 8 & 9 Undertemp: Link 8 & 9 3 - 180 sec 0.1 - 6 hours
TM5 - 0-20mA Output Hysteresis 3% fixed Hysteresis: 0 - 100% 6 - 360 sec 0.13 - 8 hours
TM4/R - Remote 1MV pot Faulty thermocouple 10 - 600 sec 0.26 - 16 hours
Hysteresis: 3% fixed Indication: Flashing LED 0.25 - 15 min 0.4 - 24 hours
Namur connect 6-7
NPN/PNP connect 5-6-7 All timers, 11 Pin & 8 Pin,
above 360 seconds: prices differ.

AC: ±1.5VA DC: 100mA @ 12VDC 8-pin Plug-In Timers

Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% The following 8-pin timers are available:
(Isolation test volts 2kV) DP1, DP2, DP3, IP2, IP3, EP1, EP2, UP1, UP2,
12, 24, 48VDC DDP1, DDP2, DDP3,
DAP1, IAP1, SDP1, PP1, TSP1
SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC & OSP1.

M1 6

FADIELSSIAGFNE POWER MONITORS

Type Phase Failure & Phase Failure & Supply Protection Over & Under Voltage
Code Sequence Relay Sequence Relay Relay Three Phase
Outputs
Mode of SMP1 1000 SMP1 SMP2 SPR3 SPR3/N TWCP1 TWCP1/N
Operation
SMP1/N SMP2/N
Connection
Diagram SPDT SPDT DPDT SPDT SPDT

This three phase (3 wire) unit This three phase (3 or 4 wire) unit SPR3: 3 Phase (3 wires) TWCP1: 3 Phase (3 wires)
monitors the supply voltage for monitors the supply voltages. The
all systems between 525 and output relay energises if the phases SPR3/N: 3 Phase + N (4 wires) TWCP1/N: 3 Phase + N
1000V. The output relay are all present, in the correct
­energises if the phases are all sequence and each voltage is within This three phase (3 or 4 wire) unit monitors the (4 wires)
­present and in the correct 5-15% range (adjustable) of each supply voltage and combines the protection
sequence. The relay other. The relay de-energises on: features of the SMP1 and TWCP1. The output This three phase (3 or 4 wire)
de-energises when any phase is a. A phase voltage imbalance
lost or the phase sequence is relay energises if the phases are all present, in window voltage comparator
incorrect. exceeding the adj limit (5-15%).
b. T otal failure of one or more the correct sequence and each voltage is to monitors the supply voltage. The
The unit is housed in a DIN rail within the adjustable over and undervoltage
mounting housing ­suitable for p­ hases. limits. output relay energises if the
1000V c­ onnections. c. Incorrect phase sequence. The relay de-energises on: voltage level is within the
d. Supply exceeds 15% under/over a. Phase voltage imbalance exceeding the adjustable over and undervoltage
limits and de-energises when the
nominal voltage (Link 2-10 10% (preset)
options).
Built-in optional facilities (SMP1 & b. Total failure of one or more phases. voltage is outside this range.
SMP1/N only)
1. 180 sec fault restart delay. c. Incorrect phase sequence. Built-in optional facilities:
2. 15% fixed over/under voltage. d. Any phase falling outside the set voltage 1. External latch
These facilities can be utilised by
connecting external links as per the range. 2. 10 sec start up delay
diagram below.
Built-in optional facilities:

1. External latch N/C 3. 180 sec fault restart delay

2. 10 sec start up delay These facilities can be utilised by
3. 180 sec fault restart delay connecting external links as per
These facilities can be utilised by connecting the diagram below.
external links as per the diagram below.

SMP1 ONLY

AUTOMATION PRODUCTS N: FOR SMP1/N ONLY N: FOR SPR3/N N: FOR TWCP1/N

Specification For any 3 phase system with a SMP1 & SMP2 – 3 Phase Link 8 & 9 Link 8 & 9
nominal voltage from 525 to 1000V. SMP1/N & SMP2/N – 3Phase + N External latch Ext. Latch N/C
Hystersis LED: Link 9 & 10 Link 9 & 10
Supply AC Supply healthy – Green Phase imbalance: 5-15% ADJ. 10 sec start up delay 10 sec start up delay
Supply DC DIN mounting housing Link 9 & 11 Link 9 & 11
Contact Rating SMP1 & SMP1/N only 180 sec fault restart delay. 180 sec fault restart delay
2% Fixed Link 8 & 9 Phase imbalance: 10% fixed
7 525-1000VAC 180sec fault restart delay Overvolts 0 - 20% ADJ. Overvolts 5 - 20% ADJ.
- Link 2 & 10 for SMP1 only Undervolts 0 - 20% ADJ. Undervolts 5 - 20% ADJ
15% fixed over/under voltage protection. LEDs:
Over/Undervolt – Red LEDs:
LED: Phase rotation – Red x2 Over voltage – Red
Supply healthy – Green Supply healthy – Green Undervoltage – Red
Available for 110, 230, 400V and 525V Supply healthy – Green
systems 2% Fixed
2% Fixed
2% Fixed 400 & 525VAC
115*, 400 & 525VAC
115, 230*, 400 & 525VAC -
-
- DPDT: 5A @ 250VAC

SPDT: 10A @ 250VAC

M1

FADIELSSIAGFNE POWER MONITORS

Over & Under Voltage Monitor Over Current Under Current Over & Under Over & Under
Voltage Single Phase Monitor Monitor Current Monitor Frequency Monitor
FR1
WCPT1 VCP1 VCP1/M OCP1 OCP1/D UCP1 UCP1/D CWP1

SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT

This new single phase The output relay is OCP1 - 1A/5A AC/DC UCP1 - 1A/5A AC/DC CWP1 - 1A/5A AC/DC The unit senses the
supply frequency and
­window voltage comparator energised when the OCP1/D - 6 0mV/150mV UCP1/D - 60mV/150mV The relay senses the the relay will energise if
the ­frequency is within
replaces WCP1 and voltage peak (peak AC/DC AC/DC input current and the the set over f­requency
limits.
monitors the supply voltage. voltage on AC) relay will energise, if the
The relay will
The ­output relay energises if overshoots the level current is within the set de-energise if the
overcurrent and f­requency rises above
the voltage level is within selected on the front Trip Point - The relay Trip Point - The relay undercurrent. the over frequency
setpoint or drops below
the adjustable over and face potentiometer. It de-energises when the de-energises when the The relay will the under frequency s­ et
de-energise if the point.
undervoltage limits and de-energises when input current rises above input current drops c­ urrent rises above the
overcurrent ­setpoint or Link 6 & 5: Under Hz
de-energises when the voltage falls below the the set point and below the set point and drops below the under­
current set point. Link 6 & 7: Over Hz
voltage is outside this normal voltage Ue by energises when the energises when the

range. 5-50% or when supply input ­current falls a input ­current rises a

Built-in optional facilities: breaks. certain percentage certain percentage

1. External latch The hysteresis is (hysteresis) below the (hysteresis) above the

adjustable and its set point. set point.
selection does not
2. 10 sec start up delay Hysteresis - The Hysteresis - The
d­ ifference between the d­ ifference between the
3. 1 80 sec fault restart delay change the chosen trip level and the set set trip level and the LEDs:
level. recovery level. Over current – Red
These facilities can be voltage level. Under current – Red

utilised by connecting

external links as per the Supply on – Green

diagram below.

SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY AUTOMATION PRODUCTS
VOLTAGE VOLTAGE VOLTAGE VOLTAGE VOLTAGE

Link 8 & 9 VCP1/M: Multi voltage UCP1 UCP1/D Response delay: 1 sec
External latch N/C inputs: OCP1 OCP1/D Over: 52 - 58Hz adjustable
Link 8 & 7 CWP1 Under: 48 - 42Hz adjustable
10 sec start up delay. Connect: Input: DC: 0 - 150MV
Link 8 & 6 5-8 0 -10VAC (RMS) DC AC: 0 - 1A Pins 5 +7 LEDs:
180 sec fault restart delay. 6-8 0.4 -40VAC (RMS) DC Pins 5 +7 0 - 60MV Over frequency – Red
7-8 4 -400VAC (RMS) DC 0 - 5A Pins 6 +7 Under frequency – Red
Overvolts 5 - 30% ADJ. 11-8 6 -600VAC (RMS) DC Pins 6 +7 Supply on – Green
Undervolts 5 to 30% ADJ. Startup delay: 10 seconds
For external pot use 10kV
LEDs:
Over voltage – Red
Under voltage – Red
Supply healthy – Green

2% Fixed 5 - 50% Adjustable 5 - 50% Adjustable 2% Fixed 2% Fixed
-
Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% (Isolation test volts 2kV)

12, 24, 48VDC (110VDC for VCP1)

SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC

M1 8

LEVEL & PUMP CONTROL

FADIELSSIAGFNE

Type Capacitive Level Relay Flip-Flop Relay Flip-Flop Mains Pump Sequence
Code Pulse Start Controlled Control Relay
Outputs
Mode of CLR1 CLR2 FNCP1 FFCP1 FFP1 FFP2 FFP3 FFP4
Operation
SPDT SPDT SPDT SPDT DPDT 3 Pumps 4 Pumps
Connection
Diagram CLR1 For alternating pumps Mains controlled: Change on Float or Pressure switches are
Using NPN Probe FNCP1 (No memory) removal of supply. c­ onnect­ed to pins 1, 11, 6 and
Filling: The relay energises Closing of contact across 5 & 7 The relay is initially in any state, on ­common on 5. When the first switch
when the level drops below the the relay will energise. Closure or off, apply supply voltage. The closes, relay 1 energises. When the
lower level sensor and of contact again, the relay will relay keeps its state. Remove the second and third switches close, the
d­ e-energises when it reaches the de-energise. When the relay is supply voltage. The relay will now second and third relays energise.
high level s­ ensor. in the ON position and the change state and will keep its state There will always be as many relays
Emptying: As above with ­supply voltage is removed, the without the supply. Apply & remove energised as there are input switch-
­opposite function. Link 7 & 9. relay will reset. (No memory). the supply again for the next es closed. When 1, 2 or 3 pressure
Using PNP Probe change in state. switches open, 1, 2 or 3 relays will
Functions reverse. FFCP1 (With memory) Mains controlled: Change on de-energise. The positions of the
NPN Sensor: SD10G-ARN1 Closure of contact across 5 & 7, application of supply. pressure switches do not matter,
Page 49 the relay will energise. On Link pins 5 and 7 (Link A). Apply only how many are switched on at a
NPN Sensor: CS-09 page 296 closure of the contact again the supply voltage. The relay changes time. When all switches open and
relay will state. Remove supply. The relay no relays are energised, and a
CLR2 de-energise. The relay remains keeps its state. switch closes again, then relay 2
2 Wire Probe ­connection: in this position even on removal Pulse controlled. Link pins 6 & 7 will be the primary relay, that is the
Probe 1 5(+) 6(–) of supply. (with memory). (Link B). The relay is initi­ally in any first relay to energise, then relay 3,
Probe 2 7(+) 6(–) state, apply supply voltage. The and then relay 4 or 1. Every time
Probes VR1A or VR1B Pg. 49. relay keeps its state. When the the first switch closes, the next
Single Probe c­ onnection: contact between pins 5 & 7 closes, relay will be the first to e­ nergise.
Probe 5(+) 7(–) the relay will change state. The supply must be connected for
Remove the supply voltage. The the relays to energise. The currently
relay will keep its state without the selected primary relay is stored in
supply. non-volatile memory. The relay will
Minimum time supply connected for remember which relay to energise
relay to react: 1 second. first, even if the supply is discon-
nected.

NB: Voltage Free Inputs
FFP3

AUTOMATION PRODUCTS CLR1 SUPPLY SUPPLY SUPPLY FFP4
VOLTAGE VOLTAGE VOLTAGE
SUPPLY
VOLTAGE FFCP1: Not available in 12VDC Response time: 0.2S
Not available in 12VDC
Response time: 500mS
Sensor connections NPN:
Pin 5 (P) H Level - Black
Pin 6 (P) Common - Brown
Pin 7 (N) Common Blue
Pin 8 (P) L Level - Black
Use VP02E or CS09

Power AC: ± 1.5VA DC: 100mA @ 12VDC
consumption
Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% (Isolation test volts 2kV)
Supply AC 12, 24, 48VDC
Supply DC
SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC
Contact Rating
M1
9

FADIELSSIAGFNE LEVEL & PUMP CONTROL PHASE ANGLE RELAYS

2-Level Liquid 3-Level Liquid Submersible Pump Pump & Motor Protection
Level Relay Level Relay Seal Monitor Phase Angle Relays

TE101 TE201 DLR DLRA SPSM TE01 / TE01/S TE02 / TE03

SPDT DPDT DPST SPDT • Supply Voltage: Single Phase: 230VAC ±20%
Three Phase: 400VAC or 525VAC ±20%
Filling: Link 7 & 8. The relay DLR For protection of submersible
energises when the level drops For alternating pumps motors against damage caused • Power Consumption: ±2VA
below the low level probe and There are two relay outputs with flip- by the ingress of water. • Calibration: Manual or Automatic (Model dependant)
de-energises when it reaches the flop action each cycle for alternating • Dry Trip Level: 10% of calibrated phase angle /
high level probe. Top and bottom duty of pumps. Relay is connected Terminals 5 & 7 ­connect to the
probes are interchangeable. to four probes. ­monitoring terminals on the current 2s delay
Emptying: No link between 7 & Filling: Link 7 & 8. Pump 1 starts s­ ubmersible motor. • Dry Restart Delay: 15 minutes to 24 hours
8. The relay energises when the when the level drops below the start
level reaches the high probe and level probe. Pump 2 will start if the The output relay energises upon adjustable
de-energises when it drops below level drops to the ­second probe. a­ pplication of power. The relay • Output Relay: SPDT 250VAC/10A
the low probe. Both pumps run until tank is full. The will de-energise if probe current • Voltage Trip Level: 10% of calibrated voltage,
• For single level sensing con- next cycle pump 2 first then pump 1. is more than 20µA or if probe
nect pins 5 & 6 (Probes 5 & 7). Emptying: No link between 7 & 8. resistance is less than 1Mohm. 2 second delay (TE02/TE03)
• 1s response time to limit effect Function as above but reversed. The relay will e­ nergise if probe • Current Trip Level: 20% of calibrated current,
of water ripple. Longer times DLRA current is less than 15µA or if
manufactured to order. For one pump & alarm probe resistance is more than 1 second delay (TE02/TE03)
Output relay energises and de-ener- 1,4Mohm. • Rapid start cycle: 3 per 15 minutes maximum
TE101B: Dual voltage 230/400V gises between 2 levels like TE101.
When extreme level is reached, the (TE03 only)
alarm output energises (2nd Relay).
Alarm can be used for high or low LED Status Indication TE02/TE03
function.
For Probes, see Pg. 48 Green Amber Red Condition

TE101LE: Long Distance ON OFF OFF Normal pumping
Emptying 150-200m FLASH OFF OFF Dry-timing or phase failure/reversal
Only available in 230V ON OFF Supply voltage low/high
and 400V OFF FLASH OFF Rapid cycle
OFF OFF ON Motor overload or phase failure
For Probes, see Pg. 48 OFF ON ON TE02/3 uncalibrated
ON FLASH FLASH TE02/3 calibrating
FLASH OFF OFF Unable to calibrate
OFF

Selection Guide

Code TE01* TE02* TE03*

11 Pin Plug In •••

Running dry- Under load

blocked in/outlet •••

Overcurrent Auto Auto

Phase Failure / Reversal ••

SUPPLY SUPPLY SUPPLY Over / Under voltage •• AUTOMATION PRODUCTS
VOLTAGE VOLTAGE VOLTAGE

Level sensor: Max Voltage on probe = 24VDC Star / Delta or Soft Start • * * • •
Probe volts 5 VAC @ 1.5mA Max Current through probe =
Adjustable sensitivity: 0 - 50 kΩ 120µA = 0.12mA. Locked Rotor ••
LEDs:
Power on – Red Shunt Required •
Seal healthy – Green
Rapid pump start protection •

Cut-out over 12 starts/hour •

AC: ± 1.5VA DC: 100mA @ 12VDC LED Status Indication ••

Galvanic isolation with internal transformer 12, 24, 48, 115, 230, 400, 525VAC ±15% Calibration Manual Auto Auto
(Isolation test volts 2kV)
12, 24, 48VDC Tank Control (float switch) •

SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC *Add to Code: 230 = 230VAC, 400 = 400VAC,
525 = 525VAC **TE01/S version only

M1 10

DIGITAL POWER MONITORS DIGITAL TIMERS

Multifunction Multifunction

Type Digital 3-Phase Voltage Digital Frequency Digital Delay On Timer 8 Function 18 Function
Relay Relay 0.025 to 99H99M

Code AEVR-YH 400VAC AEFR-Y AS14S V0DDTS V0DDTS1
AEVR-Y4 (400VAC+N)

Output Relay 5A @ 250VAC Relay 5A @ 250VAC Relay 5A @ 250VAC 1 C/O 8Amp @ 250VAC

Mounting 8 PIN plug-in/Flush mount 8 PIN plug-in/Flush mount 11 PIN plug-in DIN/Base

Specification • Over and Under Voltage • Over Frequency: 50Hz-99Hz. • Delay on Operation. • Supply Voltage:
detection which is adjustable. • Under Frequency: 10Hz-60Hz. • S upply Voltage: 230VAC, 24-240VAC/DC 50Hz
Connection • Trip Delay: 1-10sec. • Accuracy: < 0.3%. • Display: 3 Digit LCD
Diagram • O ver and Under Voltage Trip • M anual/Auto Reset with 1-5 sec • P ower consumption: < 3W. • Time Range: 0.1s - 999h
Delay adjustable 0.1-10 sec. • M aster reset on closure of • Reset Time: 200ms
trip delay. • LED Indication: Red-Relay On
• Phase Loss Detection. • Cutout Size: 62 x 50mm. contact on Pins 5 & 7. • Dimensions: 17.5 x 89 x 76
• Phase Sequence detection. • Frequency Display 0-99,9. • P ause on closure of contact on
• Phase Imbalance. V0DDTS - Functions
• Manual/Auto Reset with 1-5 sec Pins 5 & 6, timer will continue on
opening of contact. • ON Delay
trip delay. • Cycle Off/On
• Cutout Size: 62 x 50mm. • Cycle On/Off
• Voltage Display 0-999. • Signal On/Off
• Signal Off Delay
SUPPLY VOLTAGE • Interval
• Signal Off/On
• One Shot

V0DDTS1 - Functions

AEVR-YH no neutral SUPPLY SUPPLY • ON Delay
AEVR-Y4 with neutral VOLTAGE • Cycle Off/On
VOLTAGE • Cycle On/Off
Digital Timer Switch • Impulse On/Off
85-264VAC • Accumulative
Delay on Signal
DIN Timers • Accumulative Delay on
Inverted Signal
With triggering function. • Accumulative Impulse
Independant self on Signal
supply from internal • Signal On Delay
battery • Inverted Signal ON Delay
• Signal Off Delay
AUTOMATION PRODUCTS Code MCB200 Description Time Range Code • Impulse On/Off
Delay on Timer 0.1-10secs NTE8-10B • Signal Off/On
Time Ranges 0.2-9999s/0.1-9999min • Leading Edge Impulse 1
• Leading Edge Impulse 2
Supply Voltage 230V (85-315VAC/DC) 10-120secs NTE8-120B • Trailing Edge Impulse 1
• Trailing Edge Impulse 2
Output Type 1 C/O 0.5-8mins (480secs) NTE8-480B • Delayed Impulse
• Inverted Signal ON Delay
Reset Time <120ms Pulse Start Interval Timer 0.5-8mins (480secs) NTE8-480A Display

Rated Current 6A@230VAC Connection Diagram

Mounting DIN Rail Contact N/O 5 Amp @ 230VAC

Battery Life 10 Years / 1000 000 operations Supply 230VAC

Triggering Input Functions STOP 6 54 Connection Diagram
START
• Delay
• OFF Delay 654
• Pulse
• Asymmetrical Flasher 1
• Symmetrical Flasher 3 21

32

L
N

Connection Diagram

11 DPM

MINI DIN TIMERS, STAIRCASE TIMERS & DIMMERS

Timers

Operating
Temp:
-20 to 60°C

Code PCM-04* PCM-10* PCM-01* PCM-01/U PCM-02* PCM-02/U PCM-06/U
Type Multi-functional Timer Multi-functional Timer Delay ON (12-240VAC/DC) (12-240VAC/DC)
Delay OFF (no power)
Output Relay Delay OFF (Internal) or Delay ON
Function 2 C/O 8A
1 C/O - 16A 1 C/O - 16A 1 C/O - 16A 1 C/O - 16A Mode A: On application of
the supply voltage the relay
This multi-function timer has 10 This multi-function timer has 10 The one mode time relay has Upon application of the operates when the supply
volage is disconnected the
independant operating modes. independant operating modes. a delayed switch on function. supply voltage the relay timer period starts. After the
operates and the time starts. adjusted time is over the
Wide time adjustment 0.1sec to Wide time adjustment The relay is released by On the expiry of the set time relay releases.
the relay releases. The relay Time ADJ 0.15s-10m for
10 days. 0.1sec to 100 days. power to the system. is reset by Power OFF to the delay OFF.
• Delay ON operate. relay. Wide time adjustment Time ADJ 0.1s-1h for delay ON
• Delay OFF (Interval). • Unequal repeating OFF first. Wide time adjustment range: range: 0.1sec to 10 days. Power & Relay on LED
• Repeating starting with OFF. Power & Relay ON LED. Accuracy 0.2%
• Repeating starting with ON • Unequal repeating ON first. 0.1sec to 10 days. Accuracy 0.2%. Mode B: Delay ON
• Delay pulse on 0.5 secs operation
• Two shot timer ON first. Power & Relay ON LED.

• Two shot timer OFF first. Accuracy 0.2%.

• Interval pulse start on rising • Permanent switch ON mode.

edge. • Permanent switch OFF

• Interval pulse start on mode.

falling edge. •Switch ON pulse start T1

• Bistable relay with time delay and pulse OFF T2 delay.

• Switch ON/OFF delay. •Pulse start interval T1,

• Interval pulse start with second pulse T2.

retriggering. •ON pulse OFF starts T1 & T2

Supply *230VAC, *230VAC, *230VAC, *230VAC, 12-240VAC/DC
*24V(AC/DC) *24V(AC/DC) *24V(AC/DC)
*Add voltage to code *24V(AC/DC)
IP65 IP40
Operating
Temp:
-20 to 45°C

Code PCM-03* PCM-03/U ASH-01/U ASM-01/U DIP-02 DIM-20
Staircase Timer
Type (12-240VAC/DC) Staircase Timer 10 Sec - 10 Min
Time 10 Sec - 10 Min 1NO - 16A
Output relay Cycling Timer 1NO - 16A Similar to ASH-01 but in DIN Light Dimmer Light Dimmer
Function Staircase, corridor time Power: Red LED indication – –
0.1 Sec - 10 Days delay device. Operating Time adjustment: 10 secs to – –
time adjustable from 10 10mins Light intensity memory. Intelligent dimmer lighting
1 C/O - 16A secs to 10mins by means 1 Module width Compact Design. LED control unit for resistive,
of potentiometer. 2 Way indicator. 3 Wire design. Can inductive loads or
The one mode time relay switching. 3-wire or 4-wire 12-240VAC/DC fit into 4x2 flush box. Triac electronic ballasts and AUTOMATION PRODUCTS
installation. Output. Wiring: Black: Live dimmable energy saving
has an equal ON/OFF Size: 69 x 56 x 27mm flourescent lamps. DIN Rail
Brown: Load Mount. LED indicates load
repeating time delay Red: Switch on. Lighting level memory
Size: 50 x 50 x 26mm when power OFF. Energy
starting with OFF. Max load: 350VA saving in Stand-by mode.
Resistive load Max load: 500VA Resistive
Wide time adjustment Min load: 30VA or inductive load. Min:30VA

range: 0.1sec to 10 days

Power & Relay ON LED.

Accuracy 0.2%.

Supply *230VAC 12-240VAC/DC 230VAC 230VAC 50/60Hz

*Add voltage to code *24V (AC/DC)

DPM 12

PHASE FAILURE, VOLTAGE, DAYLIGHT & TEMPERATURE RELAYS

IP65

Operating
Temp:
-20 to 60°C

Code CKM-01 CKH-01 PNM-10 PNM-31 PNM-32
1 phase Over / Under
Type 3 Phase Failure & 3 Phase Failure & Voltage Relay 3 phase Over / Under Digital Display Over / Under
1 C/O - 10A
Output Relay Sequence Sequence Over / under Voltage Voltage Relay Voltage Phase Failure
Function monitoring relay. Single
1 C/O - 10A 1 C/O - 10A phase monitoring 1 C/O - 16A 1 C/O 16A
Minimum and Maximum
Phase sequence, total Phase sequence, total and voltage adjustment Over / under Voltage Protection of 3 phase systems against:
Min value: 170V - 225V
and partial loss monitoring partial loss monitoring Max value: 235V - 290V monitoring relay. Three • Phase sequence
Switch off time delay
device. Monitors wrong device. Monitors wrong adjustment: 0 to 12Secs phase monitoring • Phase failure

phase sequence, or loss phase sequence, or loss of 230VAC 50/60Hz Minimum and Maximum • Over / Under volts

of one phase. < 180V one phase. < 180V voltage adjustment adjustable 170-225V

Switch on Delay: 5-10 Secs Switch on Delay: 5-10 Secs Min value: 170V - 225V 235-290V

Switch off Delay: 1-5 Secs Switch off Delay: 1-5 Secs Max value: 235V - 290V phase to neutral volts

Voltage Threshold ADJ Voltage Threshold 185V Switch off delay 5 secs • Features:

170 - 200V Hysteresis ±10V Phase seq. LED - Delay ON time setting 2-15s

Hysteresis ±10V Correct / wrong phase Voltage asymmetry - Delay OFF time setting 2-15s

Correct / wrong phase seq. LED LED - Voltage histeresis 1-4V

seq. LED L1, L2, L3 phase LED - Voltage asymmetry level

Powered from own supply Relay ON LED setting 10-60V
Powered from own supply 400V + N
Supply 400V + N Powered from own Powered from own supply

Operating IP65 supply 400V + N 400V + N
Temp:
-20 to 45°C

Code WZH-01 WZM-01 RTM-01 RTM-20 RTM-30

Type Daylight Relay Daylight Relay Temperature Regulator Digital Temp Regulator
Supply 230VAC 50/60Hz 230VAC 50/60Hz 230VAC, 50/60Hz
1 C/O - 16A 1 C/O - 16A 230VAC 50/60Hz
Used to control lighting depending on lux DIN mounted temperature
Output relay 1NO - 16A density levels. The unit is resistant to controller. -5°C to 40°C. 1C/O - 16A
momentary changes in lighting levels Underfloor heating etc.
Function Used to control lighting Requires Light Sensor For use with standard NTC RTM-20: -5°C to 60°C.
depending on lux density Lux adj 0.1 to 200Lx sensor, from 3m to 50m
Sensor cable max length 50m (See below) RTM-30: -10˚C to 90˚C
levels. The unit is Switching delay: 30S Underfloor heating etc. LCD display
Hysteresis: +5-60Lux
resistant to momentary No freeze, comfort, economy modes
changes in lighting levels
Indication of temp value and

AUTOMATION PRODUCTS Lux adj 0.1 to 200Lx adjustable temp required.

Photocell included 24hr 7day ON / OFF settings
Size: 69 x 56 x 27mm
RTM-20 Heating only

Switching delay: 30S RTM-30 Heating & cooling

Hysteresis: +5-60Lux For use with standard NTC sensor,

from 3m to 50m. (See below)

Daylight Sensor Daylight Sensor Temperature Sensor IP67

Code SOH-* Code SOS-01 Code NTC-03
IP54 The SOS-01 is a stand-
13 The SOH is designed for alone sensor. To be used For use with the RTM-01,
operation with the with WZM-01. The length of RTM-20 and RTM-30 temp.
Daylight Switches. the interconnecting cable regulators. Cable length: 3m
*01: 1m connecting cable. may not exceed 50m. (can be extended up to 50m)
*03: 3m connecting cable Temperature -5°C to 60°C
*05: 5m connecting cable

DPM

NREAWNGE VOLTAGE & CURRENT RELAYS

1 phase 3 phase

Code LDM-10 LDM-30 PMH-01 PMM-01 PPM-05/5 (0.5-5A)
PPM-05/16 (1.6-16A)
Type Voltage Indicator Over Current Limiter Over Current Limiter
Output Relay 1 NO - 16A 1 NO - 16A Load Control Relay
Function – – AC1 4kW AC1 4kW 1 C/O - 16A
Used to monitor and Used to monitor and AC1 4kW
Supply The module is used for graphical presentation of switch off supply when switch off supply when When the adjusted current value is
either one phase or three phase voltage supply the Load power value the Load power value exceeded (term 1, 2) the monitor
system levels. The voltage value is shown by has been exceeded, Adj: has been exceeded, Adj: switches off the non-priority load, with
lines of LEDs. Range from 195V to 245VAC PH/N 0.2 - 2kW. Unit 0.2 - 2kW. Unit the adjusted time delay. Current values
Powered from own supply. measures current every measures current every and time delay can be adjusted.
LDM-30 Loss of L1 will cause total switch off 40 secs. 40 secs.
Input voltage tolerance: -15 to +10% 230VAC 50/60Hz 230VAC 50/60Hz 230VAC 50/60Hz
LDM-10: 1 phase 230VAC monitoring
LDM-30: 3 phase 400 VAC + N monitoring On application of the supply voltage, the
relay will energise, and the geyser will
Operating temp: switch on. Current adjustment can be set
-20 to 45°C so that if one stove plate is on, the gey-
ser will remain on. When the second
stove plate is switched on the geyser will
be switched off after an adjustable time
delay. Current can also be set so that
even if one stove plate is switched, the
geyser will switch off.
Use PPM-05/16 for 3kW geyser.
Use PPM-05/5 with CT's for larger loads
For geysers use external contacts.

Code PBM-01* PBM-02* SSRC-04*

Type Bi-stable Relay Liquid Level Relay

Supply *230VAC or *24V (VAC/DC) *230VAC, 400VAC

*Add voltage to code SSRC-04 is used for the level and discharge control of
conductive liquids in tanks located in industrial plants
Function Used to control lighting or other devices by and domestic applications. The output relay switches
means of a pushbutton or pushbuttons in ON when the liquid reaches the upper level electrode.
parallel. Pushing any button causes switching The output relay switches OFF when the lower level = Lamp to indicate that geyser is off. AUTOMATION PRODUCTS
on or switching off. L or N line signal. electrode is no longer in contact with the liquid. The Stove load not to exceed 16 Amps, if
PBM-02: Internal relay memory remembers sensitivity (i.e. impedance between electrodes) can be larger use external CT. Eg. DS-505
position of relay when power fails. Can be adjusted to 5-50Ω for different liquids by means of the 50/5A with relay PPM-05/5.
centrally controlled. knob of the front panel. The LED on the front panel
lights when the relay is ON position.
Output Relay 1NO @ 16A 1C/O 8A
AC 1 4kW
LED LED Green: Power LED LED Green: Power LED
Indication LED Red: Relay on LED LED Red: Relay on LED
Test button
Dimensions 17.5mm width
DIN mounting
35mm width DIN mounting
14
DPM

FFAEIALTSUARFEES POWER MONITORS

Type Current Monitor - Current Monitor - Current Window DC Current Window
Single Phase Single Phase Comparator - Single Phase Comparator

Code SP100/SP103 SP101/SP104 SP120/SP123 SP121
Features
• Internal shunt for direct in-line • Internal shunt for direct in-line sensing • Direct in-line current sensing • Combined overload and under
Connection current sensing (AC or DC) of currents up to 200mA (AC or DC) • Combined overload and underload load detection
Diagram • Adjustable responsible delay of 0.1 to • Adjustable responsible delay of 0.1 to detection • Internal shunt for direct in-line
10 seconds on SP103 10 seconds on SP104 • Internal shunt for direct in-line current sensing of currents up to
• 1A or 5A, AC or DC input range • Direct interface with DC Shunt sensing 200mA DC
(programmable) Resistors • Adjustable responsible delay of 0.1 to • Direct interface
• Direct interface with conventional • Trip point adjustable on calibrated 10 seconds on SP123 • Seperate adjustment of overload
current transformers. scale 0-100% • 1A or 5A AC input range and underload thresholds
• Trip point adjustable on percentage • Hysteresis adjustable 5-30% (programmable) • Latching in both modes
scale • Programmable for overload or • Direct interface with conventional • Range selector switch for 1mA,
• Hysteresis adjustable 5-30% underload detection. current transformers 20mA, 200mA, 60mV, 150mV,
• Programmable for overload or • Latching on overload or • Seperate adjustment of overload and and 5V
underload detection. underload (programmable). undeload threshold • LED indication for overload,
• Latching on overload or underload • Start-up delay • Latching in both modes. underload and normal load
(programmable) • 10A SPDT relay output • LED indications for overload, • Start-up delay
• Start-up delay underload and normal load. • 10A SPDT relay output
• 10A SPDT relay output • Start-up delay
• 10A SPDT relay output

DPDT on request (No Latching) DPDT on request (No Latching) DPDT on request (No Latching) DPDT on request (No Latching)

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage:12, 24, 115, 230, AC: Supply voltage:12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230,
*Relay Contacts: 400, 415, 525V ±15% 400, 415, 525V ±15% Isolation (current 400, 415, 525V ±15% 400, 415, 525V ±15%
SP = Single Pole Isolation (current input to power supply): input to power supply): 2kV Isolation (current input to power Isolation (current input to power
DP = Double Pole 2kV Power consumption: 3VA (approx), supply): 2kV Power consumption: 3VA supply): 2kV
Ordering Code Power consumption: 3VA (approx), 6VA for 415, 525V (approx) (approx), 6VA for 415, 525V (approx) Power consumption: 3VA (approx),
Example 6VA for 415, 525V (approx) DC: Supply voltage: 10-30V, 48, 60, DC: Supply voltage: 10-30V, 48, 60, 6VA for 415, 525V (approx)
DC: Supply voltage: 10-30V, 48, 60, 110V 110V ± 15% 110V ± 15% DC: Supply voltage: 12, 24, 48, 60,
± 15% Isolation: no galvanic isolation. Isolation: no galvanic isolation. 110V ± 15%
Isolation: No galvanic isolation. Power consumption: 100mA (10-30V), Power consumption: 100mA (10-30V), Isolation: no galvanic isolation.
Power consumption: 100mA 30mA for 48V and higher 30mA for 48V and higher Power consumption: 100mA (12, 24V),
(10-30V), 30mA for 48V and higher CURRENT INPUT CURRENT INPUT 30mA for 48V and higher
CURRENT INPUT Repetitive accuracy: 1% Trip point: 0.1 to 1A or 0.5 to 5A AC CURRENT INPUT
Trip point: 0.1 to 1A or 0.5 to 5A AC/DC Hysteresis: 5% to 30% (adjustable) (adjustable) Repetitive accuracy: 1%
(adjustable) Repetitive accuracy: 1% Hysteresis: 2% Fixed
AUTOMATION PRODUCTS Repetitive accuracy: 1% Range Input Max. Input Hysteresis: 2% Fixed (relative to sensitivity setting)
Hysteresis: 5% to 30% (adjustable) Impedance (Continuous) (relative to trip point setting)
Maximum input current 1mA Maximum input current (continuous): Range Input Max. Input
(continuous): 6A 20mA 60 Ohm 60mA 6A Impedance (Continuous)
Peak short-term over-current 200mA 3 Ohm 350mA Peak short-term over-current (10 1mA
(10 seconds): 20A 60mV 0.7 Ohm 800mA seconds): 20A 20mA 60 Ohm 60mA
Current input impedance: 50 milliohms. 150mV Current input impedance: 50 milliohms 200mA 3 Ohm 350mA
RESPONSE 5mV 10k 50V RESPONSE 60mV 0.7 Ohm 800mA
Start-up delay: Approximately 10 10k 50V Start-up delay: approximately 10 150mV
seconds, standard. (0.1 to 15 seconds 10k 50V seconds, standard (1 to 15 seconds 5mV 10k 50V
also possible on special order) Response also possible on special order) 10k 50V
Delay: SP100 - 1 second, SP103 - RESPONSE Response delay: SP120 - 1 second. 10k 50V
adjustable from 0.1 to 10 seconds (other Start-up delay: approximately 10 SP123 - adjustable from 1 to 10
ranges on special order) seconds, standard. (1 to 15 seconds also seconds (other ranges on special RESPONSE
possible on special order) Response order) Start-up delay: approximately 10
delay: SP101 - 1 second. SP104 - seconds, standard (1 to 15 seconds
adjustable from 0.1 to 10 seconds (other also possible on special order)
ranges on special order) Response delay: SP121 - 1 second

TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
SP 100 SP 101 SP 120 SP 121
230V AC S*P 230V AC * 230V AC * 230V AC *

15 RHE

FFAEIALTSUARFEES POWER MONITORS

Type Voltage Monitor - Voltage Window Comparator - Voltage Window Comparator Combined Over/Under Voltage
Single Phase
Single Phase - Single Phase AC/DC Monitor, 2 Independent Relays

Code SP200/SP201 SP220/SP221 AP221 AP224
Features
• Programmable input voltage range • Combined over-voltage and • DIN rail format • DIN rail format
0 to 600V AC(RMS) or DC under-voltage detection • Combined over-voltage and • Combined over and under
• Adjustable response delay from 0.1 • Adjustable response delay of 0.1 under-voltage monitoring detection voltage
to 10 seconds on SP201 to 10 seconds on SP221 • Monitoring of own supply voltage • Internal shunt for direct in-line
• Voltage threshold adjustable on • Monitoring of own supply voltage • Selectable power supply voltages sensing of currents up to
calibrated scale, 0-100% • High precision and repetitive • High precision and repetitive accuracy 200mA DC
Adjustable hysteresis 5-30% accuracy • Independent adjustment of • Direct interface
• Programmable for over-voltage or • Independent setting of over- over-voltage and under-voltage • Seperate relay for over-voltage
under-voltage detection voltage and under-voltage tripping setpoints and under-voltage
• Latching on over-voltage or under- points • Adjustable response times • Seperate adjustment of
voltage • LED indication for type of fault available on trip and/or recovery overload and underload
• 10A SPDT relay output and status of the relay (0.1-10 secs) thresholds
• Latching facility • Adjustable start-up delay (0-10 secs) • Latching in both modes
• 10A SPDT relay output • Latching on over-voltage or under- • Range selector switch for 1mA,
voltage fault conditions 20mA, 200mA, 60mV, 150mV,
(programmable) and 5V
• LED indication for Relay ON, over- • LED indication for overload,
voltage & undervoltage underload and normal load
• 5A DPDT relay output • Start-up delay
• 5A DPDT relay output

Connection Voltage Input 6
Diagram AC or DC 57
48
6 Under volts Over volts
57 39
48 DPDT only SPDT only (2x single pole relay)
2 10
39 1 11
2 10
1 11 AC or DC
Power Supply
~ AC ~ DPDT on request (No Latching)
Power Supply
DPDT on request (No Latching)

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY AUTOMATION PRODUCTS
AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230, AC: 12, 24, 115, 230, 400, 525V AC AC: Supply voltage: 12, 24, 115, 400,
*Relay Contacts: 400, 415, 525V ±15% 400, 415, 525V ±20% Isolation: Galvanic (without latching) 525V AC
SP = Single Pole Isolation (current input to power Isolation (current input to power Power consumption: 2VA (approx) Isolation: Galvanic (without latching)
DP = Double Pole supply): 2kV supply): 2kV Housing width: 45mm Power consumption: 2VA (approx)
Ordering Code Power consumption: 3VA (approx), Power consumption: 3VA (approx), Voltage tolerance: ±20% Housing width: 45mm
Example 6VA for 415, 525V (approx) 6VA for 415, 525V (approx) DC: Supply voltage: 12, 24, 48, 60, Voltage tolerance: ±20%
DC: Supply voltage: 10-30V, 48, 60, DC: Supply voltage: 12, 24, 48, 60, 110V DC DC: Supply voltage: 12, 24, 48, 60,
110V ± 15% 110V ±20% Isolation: No galvanic isolation 110V DC
Isolation: No galvanic isolation Isolation: no galvanic isolation Power consumption: 30mA (approx) Isolation: No galvanic isolation
Power consumption: 100mA Power consumption: 100mA (12, 24V), Housing width: 45mm Power consumption: 30mA (approx)
(10-30V), 30mA for 48V and higher 30mA for 48V and higher Voltage tolerance: ±20% Housing width: 45mm
VOLTAGE INPUT VOLTAGE SENSING VOLTAGE SENSING Voltage tolerance: ±20%
Repetative accuracy: 1% Calibrated to respond to RMS of a Repetitive accuracy: 1% VOLTAGE SENSING
Hysteresis: 5% to 30% (adjustable) sinusoidal waveform Hysteresis: 2% fixed Repetitive accuracy: 1%
Repetitive accuracy: 1% Hysteresis relates to the supply Hysteresis: 2% (fixed)
Range Input Max. Input Hysteresis: 2% fixed (relative to its voltage Setpoints: The unit is calibrated to
Impedance Voltage supply voltage) Setpoints: The unit is calibrated to trip on the RMS value of the supply
0-15V Response dealy: SP220 - 1 second trip on the RMS value of the supply voltage (assuming no AC waveform
0-30V 500k Ohm 700V SP221 - adjustable from 0.1 to 10 voltage (assuming no AC waveform distortion)
0-60V 500k Ohm 700V seconds (other ranges on special distortion) RESPONSE
0-150V 500k Ohm 700V order) RESPONSE Response time on trip:
0-300V 500k Ohm 700V Latching disabled during power-up: Response time on trip: 0,1 - 10 seconds (adjustable)
0-600V 500k Ohm 700V approx. 10 seconds 0.1 - 10 seconds (adjustable) Response time on recovery:
500k Ohm 700V Response time on recovery: 0,1 - 10 seconds (adjustable)
0.1 - 10 seconds (adjustable) Start-up delay: 0 - 10 seconds
RESPONSE Start-up delay: (adjustable)
Response delay: SP200 - 1 second 0 - 10 seconds (adjustable) Latching inhibited during power up
SP201 - adjustable from 0.1 to 10 sec- Latching inhibited during power up
onds (other ranges on special order)
Latching disabled during
power-up: approx. 10 seconds

TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
SP 200 SP 220 AP 221 AP 224
230V AC * 230V AC * 230V AC DP 230V AC SP

RHE 16

FFAEIALTSUARFEES POWER MONITORS

Type Voltage Window Comparator - Voltage Window Comparator - Combined Over/Under- Frequency Monitor
Three Phase
Three Phase Voltage Monitor, Three Phase

Code SP230/SP231/SP232 AP231/AP232 AP234/AP235 SP320
Features
• Combined over-voltage and • Combined over-voltage and under • DIN rail format • Monitoring frequency of own
Connection under-voltage detection voltage monitoring • Combined over-voltage and under- power supply
Diagram • Monitoring of own supply voltage • Monitoring of own supply voltages voltage monitoring • High precision and repetitive
• Adjustable response delay on • AP232 available with neutral • Seperate relays for over-voltage accuracy
SP231 • Selectable power supply voltages and under-voltage • Independent setting of over
• SP232 available with neutral • High precision and repetitive accuracy • Monitoring of own supply voltage and under-frequency tripping
• High precision and repetitive • Independent adjustment of over- • AP235 Available with neutral point
accuracy voltage and under-voltage setpoints • Selectable power supply voltages • LED indication of type of fault
• Independent setting of over- • Separately adjustable response times • High precision and repetitive and relay status
voltage tripping points on trip and recovery (0.1 to 10 secs.) accuracy • Programmable for over-
• LED indication for type of fault • Adjustable start-up delay (0-10 • Independent adjustment of over frequency, under-frequency or
and status of the relay seconds) voltage and under-voltage setpoints frequency window detection
• Latching facility • Latching of fault conditions (prog.) • Adjustable response times - • Start-up delay
• 10A SPDT relay output • Microprocessor technology available on trip and/or recovery • 10A SPDT relay output
incorporated (0.1 to 10 seconds)
• LED indication for type of fault and • LED indication of over-voltage
relay status relay on and under-voltage relay
• 5A DPDT relay as standard on (power LED flashes when timing)
• DIN rail mounting • 8A SPDT over-voltage relay output

Link for start-up delay

SP-230/231 AP-231 AP-234
SP-232 AP-232 AP-235

DPDT on request (No Latching) DPDT only SPDT only (2x single pole relay) DPDT on request

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
Supply type: AC transformer supply Supply voltage: 12, 24, 115, 230,
*Relay Contacts: Supply voltage (phase-to-phase): 115, Supply type: AC transformer supply only only 400, 415, 525V, AC ±15%
SP = Single Pole Supply voltage: 115, 230, 400, 525V Power consumption: 3VA
DP = Double Pole 230, 400, 415, 525V AC ±15% Supply voltage: 115, 230, 400, 525V AC (approx), 6VA for 415, 525V
Housing width: 45mm (approx)
Power consumption: 3VA (approx), 6VA Housing width: 45mm Power consumption: 2VA (approx) Supply frequency: 42Hz - 58Hz
Isolation: Galvanic (60Hz available on special order)
for 415, 525V AC (approx) Power consumption: 2VA (approx) (without latching) RESPONSE
Voltage tolerance: ±20% Start-up delay: Approximately 10
VOLTAGE SENSING Isolation: Galvanic VOLTAGE SENSING seconds standard
Setpoints: The unit is calibrated to (1 to 15 seconds available on
Calibrated to respond to the RMS of a Voltage tolerance: ±20% trip on the RMS value of the supply special order)
voltage (assuming no AC waveform Response delay: 1 second
sinusoidal waveform. VOLTAGE SENSING distortion) FREQUENCY SENSING
Repetitive accuracy: 1% Repetitive accuracy: 1%
Repetitive accuracy: 1% Setpoints: The unit is calibrated to trip Hysteresis: 2% (fixed) Hysteresis: 0.5 Hz fixed
Hysteresis relates to the supply
Hysteresis: 2% fixed on the RMS value of the supply voltage voltage
RESPONSE
(relative to its supply voltage) (assuming no AC waveform distortion) Response time on trip: 0.1 - 10
seconds (adjustable)
Response delay: 1 second Repetitive accuracy: 1% Response time on recovery: 0.1 - 10
seconds (adjustable)
Latching disabled during power-up: Hysteresis: 2% (fixed) Start-up delay: 0 - 10 seconds
(adjustable)
AUTOMATION PRODUCTS approx. 10 seconds - SP231 Only Hysteresis relates to the supply voltage Latching inhibited during power up

RESPONSE

Response time on trip: 0.1 - 10 seconds

(adjustable)

Response time on recovery: 0.1 - 10

seconds (adjustable)

Start-up delay: 0 - 10 seconds

Latching inhibited during power up

Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
Example SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
SP 230 AP 231 AP 234 SP 320
230V AC * 230V AC DP 230V AC SP 230V AC *

17 RHE

FFAEIALTSUARFEES Phase Sequence, Phase Failure, POWER MONITORS
Phase Asymmetry Detector
Type Phase Sequence, Phase Failure, Single Phase, Reverse Power Phase Sequence, Phase Failure, Phase
Phase Assymetry Monitor Monitor (Generator Protection) Asymmetry Detector withAlarm

Code SP430/SP431 AP430/AP432 SP510 SX125/SX131
Features
• Detection of phase asymmetry • DIN rail mount • Reverse current tripping level • Detection of phase asymmetry
Connection • Adjustable sensitivity • Detection of phase asymmetry adjustable up to 20% of • Clear warning alarm when
Diagram • Insensitive to regenerated EMF • Adjustable Negative Phase maximum forward current detection has taken place
• High stability under harmonic Sequence (NPS) sensitivity • Current monitoring through (SX125)
distortion • Insensitive to regenerated EMF internal shunt • 5mm bright LED indication with
• Insensitive to balanced supply • High stability under harmonic • Response time adjustable up detection (SX125 & SX131)
voltage variations distortion to 10 seconds • Insensitive to regenerated EMF
• Fast response to reversed • Insensitive to balance supply • Start-up delay adjustable up • High stability under harmonic
phase sequence voltage variations to 10 seconds distortion
• SP431 available with neutral • Fast response to reversed phase • Insensitive to changes in • Insensitive to balanced supply
• 10A SPDT Relay output sequence power factor voltage variations
• AP432 Available with neutral • LED indication for reverse • Fast response to reversed phase
• Power ON and Relay ON LED’s power and Relay ON sequence
• Latching facility • 10A DPDT Relay Output
• 10A SPDT Relay output

Specifications SP-430 SP-430 DPDT On Request (No Latching) DPDT Only
SP-431 SP-432
POWER SUPPLY POWER SUPPLY
DPDT on request SPDT On Request Supply voltage: 115, 230, 400, 415, Supply voltage (phase-to-phase):
525V AC ±15% 115, 230, 400, 525V AC ±20%
POWER SUPPLY POWER SUPPLY Power consumption: 3VA Power consumption: 3VA
Supply voltage (phase-to-phase): Type: AC transformer (approx), 6VA for 415, 525V AC (approx), 6VA for 415, 525V AC
115, 230, 400, 525V AC ±20% (2kV galvanic isolation) (approx) (approx)
Power consumption: 3VA Voltage: 115, 230, 400, 525, 550V CURRENT INPUT VOLTAGE SENSING
(approx), 6VA for 415, 525V AC Tolerance: ±20% Input current range: 0 - 5A AC Repetitive accuracy: 1%
(approx) Power consumption: 2VA (approx) Reverse current sensitivity: Hysteresis: 2% fixed (relative to its sup-
VOLTAGE SENSING HOUSING 100mA to 1A AC (adjustable) ply voltage)
Repetitive accuracy: 1% 250V and below: 22.5mm width Repetitive accuracy: 1% Response delay: 1 second
Hysteresis: 2% fixed Above 250V: 45mm width Hysteresis: 5% (fixed) (approx)
(relative to its supply voltage) VOLTAGE SENSING Maximum input current
Response delay: 1 second Repetitive accuracy: 1% (continuous): 6A
(approx) Hysteresis: 2% (fixed) Peak short term over current
Hysteresis relates to the supply (10 seconds): 20A
voltage Current input impendance: AUTOMATION PRODUCTS
Response delay: 1 second (approx) 50 milliohms
RELAY RESPONSE
Relay options (250V): 10A SPDT Start-up delay: 0 - 10 seconds
or 5A DPDT (adjustable)
Response delay: 1 - 10 seconds
(adjustable)

*Relay contact
SP= Single Pole
DP= Double Pole

Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER
Example SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY
SP 430 AP 430 SP 510 SX 125
230V AC * 230V AC * 230V AC * 230V AC

RHE 18

FFAEIALTSUARFEES ELECTRONIC TIMERS

Type Multi-Function Timer Multi-Function Timer Electronic Reset Timer Electronic Reset Timer

Code ST100/ST101 AT100 ST110/ST111/ST112/ST113 AT110
Features
• Programmable functions: • 4 programmable functions: • Programmable functions: Delayed • Programmable functions: Delayed ON,
Connection Delayed ON, Interval (one shot), Delayed ON, Interval (one shot) or ON, Interval (one shot), both with Interval (one shot), both with hold or pulse
Diagram Equal Repeating Equal Repeating (OFF/ON first) hold or pulse reset reset
• Programmable functions and • Programmable in six independent • 18 overlapping programmable time ranges
independent overlapping time • 18 overlapping programmable overlapping time ranges from 0,2 seconds to 100 hours, achieved by:
ranges time ranges from 0,2 seconds to • Direct interface with DC three-wire · 3 programmable time ranges:
• Extended supply voltage range: 100 hours, achieved by: NPN (ST110/ST111) and PNP seconds, minutes, hours
10V to 30V AC/DC, 90V to 250V AC · 3 programmable time ranges: (ST112/ST113) sensors · 6 programmable time scales for
• Specific power supply voltage seconds, minutes, hours • High speed electronic reset & each of 3 time ranges
available on request · 6 programmable time scales repetitive accuracy • Time Setting on calibrated scale(10 -100%)
• Time adjustment on calibrated for each of 3 time ranges • Time adjustment on calibrated • High speed electronic reset and high
scale: 0 - 100% scale, 0-100% repetitive accuracy
• High repetitive accuracy • Time Settings on calibrated scale • 5A double pole relay output (10A • Direct interface with DC three-wire
• 5A DPDT relay output (10% - 100%) SPDT offered on request) NPN/PNP sensors, with reset inputs
• Time range: ST100: Up to 120 sec. • High repetitive accuracy • Time Ranges: for either PNP or NPN in the same unit
ST101: Up to 240 min • Microprocessor technology ST110/ST112: Up to 120 sec • Power ON, Relay ON and reset LED’s
• Extended time ranges available up • Power ON and Relay ON LED’s ST111/ST113: Up to 240 min • Flashing Power ON LED when unit is timing
to 25 hours or 200 hours on special • Flashing Power ON LED when unit • Extended time ranges available up • Microprocessor technology incorporated
order is timing to 200 hours on special orders • 5A SPDT or DPDT relay output
• 5A SPDT or DPDT relay output

SPDT SPDT SPDT SPDT
DPDT DPDT DPDT DPDT

Instantaneous Contacts & External Pot available

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230,
Not galvanic: 230VAC = 90 - 250VAC 400, 525V 400, 415, 525V ±15%. Isolation (reset AC: Supply voltage: 12, 24, 115, 230,
Galvanic: 12, 24, 115, 230, 400, 415, Power Consumption: 2VA (approx) input to power supply): 2kV 400, 525V
525V ±15% Tolerance: ±15% Power consumption: 3VA (approx), 2kV Galvanic isolation
Power consumption: 3VA (approx), AC Reactive: Supply Voltage: 6VA for 415, 525V (approx) Power Consumption: 2VA (approx)
6VA for 415, 525V (approx) 230VAC = 90-250VAC DC: Supply voltage: 10-30V, 48, 60, Tolerance: ±15%
DC: Supply voltage: 48, 60, 110V ±15% Power consumption: 2VA (approx) 110V ± 15% Isolation: no galvanic DC: Supply Voltage: 48, 60, 110V
Power consumption: 30mA DC: Supply Voltage: 48, 60, 110V isolation. Power consumption: 100mA Power Consumption: 30mA (approx)
AC/DC: Supply voltage: 10 - 30V Power Consumption: 30mA (appro.) (10-30V), 30mA for higher ranges Tolerance: ±15%
Power consumption: 100mA Tolerance: ±15% RESET INPUT AC/DC: Supply Voltage: 12/24V
Reset: Power supply to be interrupted AC/DC: Supply Voltage: 12/24V Reset time: 2 milliseconds Power Consumption: 100mA (approx)
for at least 0,5 seconds. For high speed Power Consumption: 100mA (approx) Short circuit current: 1mA Tolerance: ±15%
reset applications, refer to ST110 Tolerance: 15% Open circuit voltage: 8.2V RESET INPUT
TIME SPECIFICATION 12V DC OUTPUT: Input type: NPN Sensor, PNP
ST-100 Setting Accuracy: 5% Voltage tolerance: 10-15V DC Sensor, Potential free contact
Repeatability: 0.5% Source current: 30mA (max.) Minimum Pulse width: 4mS
Switch S1 Time Ranges HOUSING Open circuit Voltage: <5, 6V
250V and below: 22,5mm width. HOUSING
AUTOMATION PRODUCTS 1,8s - Up to 1,8s Above 250V: 45mm width ST-110/112 250V and below: 22,5mm width
7,5s - Up to 7,5s RELAY Above 250V: 45mm width
**L = Extended 15s - Up to 15s Relay Options (250V, 5A)SPDT, DPDT Switch S1 Time Ranges RELAY
Time Range 30s - Up to 30s TIME RANGES (STANDARD) Relay Options: (250, 5A)SPDT or DPDT
**E = External Pot 60s - Up to 60s 2: 0.2 to 2 sec, min or hrs 1,8s - Up to 1,8s DC OUTPUT
**I = Instantaneous 120s - Up to 120s 5: 0.5 to 5 sec, min or hrs 7,5s - Up to 7,5s Voltage tolerance: 10-24V
Contacts 10: 1 to 10 sec, min or hrs 15s - Up to 15s Source Current: 10mA
**TX = Galvanic ST-101 20: 2 to 20 sec, min or hrs 30s - Up to 30s Setting Accuracy: 5%
50: 5 to 50 sec, min or hrs 60s - Up to 60s Repeatability: 0,5%
*Relay contact Switch S1 Time Ranges 100: 10 to 100 sec, min or hrs 120s - Up to 120s TIME RANGES (STANDARD)
SP= Single Pole 2: 0,2 to 2 sec, min or hrs
DP= Double Pole 220s - Up to 220s ST-111/113 5: 0,5 to 5 sec, min or hrs
7,5m - Up to 7,5m 10: 1 to 10 sec, min or hrs
15m - Up to 15m 220s - Up to 220s 20: 2 to 20 sec, min or hrs
60m - Up to 60m 50: 5 to 50 sec, min or hrs
120m - Up to 120m 7,5m - Up to 7,5m
240m - Up to 240m 100: 10 to 100 sec, min or hrs
15m - Up to 15m

60m - Up to 60m

120m - Up to 120m

Extended time range available on 240m - Up to 240m
special order: 6, 12, 5, 25, 50, 100,
and 200 hours Extended time ranges on special order:

• 6, 12, 5 and 25 hours

• 50, 100, and 200 hours

Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
Example SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
ST 100 AT 100 230V ST 110
230V AC ** * AC * 230V AC ** * AT 110 230V AC *

19 RHE

FFAEIALTSUARFEES ELECTRONIC TIMERS

Type Star-Delta Timer Star-Delta Timer Unequal Cycling Timer Unequal Cycling Timer

FCeoadtueres ST130 AT130 ST200/ST201/ST202/ST203 AT200
Features
• Relay de-energises to “centre-off” • Relay de-energises to “centre-off” • Programmable OFF-cycle first or • Programmable for either OFF-cycle
Connection position for failsafe operation position for failsafe operation ON-cycle first first or ON-cycle first
Diagram • Adjustable time range of 0-60 • Adjustable Star Time range of up to • Programmable in 6 overlapping • 12 overlapping programmble time
seconds 60 seconds time ranges ranges from 0,2 seconds to 4 hours
• Incorporates 75 millisecond pause • Fixed 75/50 millisecond pause • Extended time ranges available up • High repetitive accuracy
time to prevent overlapping of Star time to prevent overlapping of Star to 25 hours or 200 hours on special • Power ON and Relay ON LED’s
and Delta switching and Delta switching order • Flashing Power ON LED when unit is
• LED indication of relay output • LED indication of relay output • Seperate off/on time adjustment on timing (flash rate increases when
status, i.e.: Star or Delta mode status i.e. Star or Delta mode calibrated scale, 0-100% relay is about to switch)
• Two relay method for interlocking • Two SPDT relays with neutral • High repetitive accuracy • Microprocessor technology
of contacts ensuring break before centre position ensure break before • 5A DPDT relay output (10A SPDT incorporated
make make offered on request) • 5A SPDT or DPDT relay output.
• 5A relay output • Microprocessor technology • Seperate OFF/ON time range
• Rated for continuous operation incorporated Timer T1 T2 selection and time adjustments on
• 5A SPDT relay output calibrated scales, 0-100%
• Rated for continuous operation ST200 A A • Link Y1/Y2 to Y3 for minutes
ST201 A B • Link Y3 to Y4 for “On” first
ST202 B B
ST203 B A

AC or DC SPDT SPDT
Power Supply DPDT DPDT
External Pot available, Pins 5, 6, 7
2x External Pot available, Pins 5, 6, 7 POWER SUPPLY
POWER SUPPLY (Off cycle first only) AC: Supply voltage: 12, 24, 115, 230,
AC: Supply voltage: 48, 60, 115, 400, 525V
Specifications 230, 400, 415, 525V ±15% POWER SUPPLY POWER SUPPLY 2kV Galvanic isolation AUTOMATION PRODUCTS
Power consumption: 3VA (approx), AC Transformer: Supply Voltage: AC: Supply voltage: Power Consumption: 2VA, 6VA (approx)
**L = Extended 6VA for 415, 525V (approx) 12, 24, 115, 230, 400, 525V ±15% 230, 400, 415, 525V ±15% Tolerance: ±15%
Time Range AC Reactive: Supply voltage: 2kV galvanic isolation AC Reactive: Supply voltage: AC Reactive: Supply voltage:
**E = External Pot 230V (90-250V) Power consumption: 2VA, 6VA 230V (90-250V) 230V (90-250V)
**I = Instantaneous DC: Supply voltage: 10-30V (approx) Power consumption: Power Consumption: 100mA
Contacts AC/DC, 48, 60, 110V DC ±10% AC Reactive: Supply voltage: 3VA, 6VA for 415, 525V (approx) DC: Supply Voltage: 48, 60, 110V
**TX = Galvanic Isolation: no galvanic isolation 230V (90-250V) DC: Supply voltage: Power consumption: 30mA
Power consumption: 100mA for Power consumption: 100mA 48, 60, 110V DC ±15% Tolerance: ±15%
10-30V AC/DC, 30mA for higher DC: Supply voltage: 48, 60, 110V Power consumption: 30mA AC/DC: Supply voltage: 12/24V
ranges Power Consumption: 30mA ±15% AC/DC: Supply voltage: 10-30V Power consumption: 100mA
RESET AC/DC: Supply voltage: 12/24V AC/DC. Power consumption: 100mA Tolerance: ±15%
Power supply to be interrupted for Power consumption; 100mA ±15% RESET HOUSING
at least 1 second HOUSING Power supply to be interrupted for at 250V and below: 22.5mm width
TIME SETTINGS 250V and below: 22,5mm width least 0,5 seconds Above: 45mm width
0 - 60 seconds adjustable Above 250V: 45mm width Extended time ranges available on RELAY
PAUSE TIMER RELAY: special order: 6, 12.5, 25, 50, 100 Relay options (250V, 5A): SPDT, DPDT
Approximately 75 milliseconds Relay Options (250V, 5A): SPDT and 200 hours TIME SPECIFICATION
±10% (1x SPST for Delta and 1x SPST Setting
for Star) A Accuracy 5% Repeatability 0.5%
RESET TIME RANGES (STANDARD)
Power supply to be interrupted for at Switch Position Time Ranges 2: 0,2 to 2 sec or min
least 1 second 6: 0,6 to 6 sec or min
PAUSE TIME 1 - Up to 1,8s 20: 2 to 20 sec or min
2 - Up to 7,5s 60: 6 to 60 sec or min
75 milliseconds 3 - Up to 15s 120: 12 to 120 sec or min
4 - Up to 30s 240: 24 to 240 sec or min
5 - Up to 60s
6 - Up to 120s

B

STAR TIME ADJUSTMENT 7 - Up to 220s
8 - Up to 7,5m
*Relay contact SPDT FUNCTION 9 - Up to 15m
SP= Single Pole 10 - Up to 60m
DP= Double Pole S1 60s Delay / 75ms Pause 11 - Up to 120m
S2 30s Delay / 75ms Pause 12 - Up to 240m
S3 60s Delay / 50ms Pause
S4 30s Delay / 50ms Pause

Ordering Code TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER STAR TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
Example SUPPLY SUPPLY TIME SUPPLY CONTACTS SUPPLY CONTACTS
ST 130 230V AT 130 AT 200
AC 230V AC S1 ST 200 230V AC ** * 230V AC *

RHE 20

ELECTRONIC TIMERS

Type Multi-function Asym- No Power Delay AC Interval or Comple- Multi-Start Attempt Unit Multi-Start Attempt Unit
metrical Reset Timer OFF Timer mentary Lamp Flasher

FFAEIALTSUARFEES

Code ST210 ST300/ST301 ST410/ST411 ST500 AT500
Features
• 6 Programmable reset functions • Internal NiCd battery back-up • Programmable: continuous • Programmable number of • Programmable number of start
attempts: 3 to 8
with hold or pulse reset or on ST301 flashing or interval flashing starts: 3 to 8 • Start failure alarm output
• Seperately adjustable starter
both, and power supply on reset • Programmable in 6 independent • Adjustable interval 1-10 secs • Adjustable cranking time: and pause times
• Adjustable starter time:
• Programmable in 6 independent overlapping time ranges • Pulse rate of 90 flashes per 1 to 10 seconds 1 to 20 seconds
• Adjustable pause time:
overlapping time ranges up to • Time adjustment on calibrated minute as standard (other rated • Start failure alarm output 1 to 20 seconds
• Power On, Start Relay and
120 seconds scale, 0-100% on special order) Alarm Relay LED’s
• Microprocessor technology
• Direct interface with DC three- • High repetitive accuracy • Solid state switching incorporated
• 5A SPDT Start Relay
wire NPN sensor • 10A single pole or 5A double • Switching capacity 4A, 1000W • 5A SPDT Alarm Relay
(start failure)
• High speed electronic reset pole relay output / 250V
• High repetitive accuracy • Time ranges: • Power supply range
• Time adjustment on calibrated 90V-250VAC
scale, 0-100% • ST300: up to 120 sec • Two wire in-line connection
• ST301: up to 240 min

• 5A double pole relay output (ST410) or three wire in-line
(10A SPDT offered on request) connection (ST411)

Connection
Diagram

SPDT SPDT
DPDT DPDT

AC or DC AC or DC ST410 AC or DC
Power Supply Power Supply ST411 Power Supply

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY

AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 12, 24, 115, Supply voltage: 230 (90-250V) AC: Supply voltage: 48, 60, 115, AC: Supply Voltage: 12, 24, 115,

230, 400, 415, 525V ±10% 230, 400, 415, 525V ±15% Supply frequency: 45-70Hz 230V ±15% 230, 400, 525V

Isolation (reset to power supply): Power consumption: 3VA, Minimum load: 15W (250VAC), Power consumption: 3VA (approx) 2kV galvanic isolation

2kV 6VA for 415, 525V (approx) 10W(110VAC) DC: Supply voltage: 48, 60, 110V Power Consumption: 2VA

Power consumption: 3VA, 6VA for DC: Supply voltage: 48, 60, Maximum load: 1000W ±15% (approx)

400, 415, 525V (approx) 110V ±15% (250VAC), 400W (110VAC) Power consumption: 30mA Tolerance: ±15%

DC: Supply voltage: 10-30V Power consumption: 30mA Maximum load current: AC/DC: Supply voltage: AC Reactive: Supply voltage:

48, 60, 110V DC ±15% AC/DC: Supply voltage: 12V 4A continuous 10-30V AC/DC 230 (90-250V)
Isolation: no galvanic isolation AC/DC and 24V AC/DC
Power consumption: Power consumption: 100mA TIMING Power consumption: 100mA Power Consumption: 2VA
100mA (10-30V), 30mA for
Flash rate: 90 flashes per minute RESET DC: Supply Voltage: 48, 60, 110V

higher ranges (standard). Optional pulse rates Power supply to be Power consumption: 30mA

RESET INPUT available on special order interrupted for at least Tolerance: ±15%

Reset time: 6ms Interval: 1-10 seconds 0,5 seconds AC/DC: Supply voltage: 12/24V

Short circuit current: 2mA ST-300 (adjustable) NUMBER OF START Power consumption: 100mA
Open circuit voltage: 8,2V
AUTOMATION PRODUCTS 12V DC Output: Voltage RESET 3 to 8 (programmable) Tolerance: ±15%
tolerance 10-15V DC
Source current: 30mA (max) Switch S1 Time Ranges Power supply to be interrupted DURATION OF START ATTEMPT HOUSING
Adjustable from 1 to 10 seconds 250V and below: 22.5mm width
1,8s - Up to 1,8s for at least 5 seconds Above 250V: 45mm width
7,5s - Up to 7,5s ALARM RELAY
15s - Up to 15s DURATION OF PAUSE Contact rating 250V, 5A SPDT
30s - Up to 30s Equal to set duration of start STARTER RELAY
60s - Up to 60s attempt
120s - Up to 120s

Switch 220s ST301 Contact rating 250V, 5A SPDT
Position 7,5m
Time Ranges 15m - Up to 220s START ATTEMPTS
1 60m - Up to 7,5m
2 - Up to 1,8s 120m - Up to 15m Number of Start Attempts: 3 to 8
3 - Up to 7,5s 240m - Up to 60m
4 - Up to 15s - Up to 120m Duration of Start Attempts:
5 - Up to 30s - Up to 240m
*Relay contact 6 - Up to 60s Adjustable from 1 to 20 secs
SP= Single Pole - Up to 120s
DP= Double Pole **I = Instantaneous Contacts Duration of Pause between Start

Attempts: Adjustable from 1 to 20

secs

Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER RELAY
Example SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY SUPPLY SUPPLY CONTACTS
ST 410 ST 500
ST 210 230V AC * ST 300 230V AC ** * 250V AC 230V AC AT 500 230V AC SP

21 RHE

PROCESS CONTROLLERS

Type Control Module for resistive Liquid Level Control Module Liquid level controller Level Control Module for
Sensors NAMUR Sensor

FFAEIALTSUARFEES FFAEIALTSUARFEES FFAEIALTSUARFEES

Code SC100 SC130 AC130 SC230
Features
• Senses conductivity between two • Programmable for charging and • Programmable for charging and • Interfaces with industrial standard NA-
Connection probe terminals providing a relay discharging operation discharging operation MUR sensors (inductive or capacitive)
Diagram output if conductivity exceeds a • AC modulation of probe signal to • AC modulation of probe signal to • Low power sensor signal to DIN19234
set limit prevent plating and electrolytic prevent plating and electrolytic • Programmable charge or discharge
• AC modulation of probe signal to corrosion corrosion modes
prevent plating and electrolytic • Low voltage, probe signal for • Low voltage, probe signal for • Programmable single or double
corrosion human safety human safety sensor selection
• Low voltage probe signal for • Adjustable sensitivity • Adjustable sensitivity • Independent indication of each
human safety • DC or AC power supply option • Power ON and RELAY ON LED’s sensor status
• Adjustable sensitivity from 15k to • 10A SPDT relay output • 5A SPDT or DPDT relay output • Seperate cable fault indication for
500k Ohm each sensor
• 10A SPDT relay output • Failsafe operation under cable fault
conditions
Possible Applications: • Direct interface with solid state relay
• Protected NPN output for direct
• Liquid Level Control interface with PLC’s or counters
• Flame Detection / Daylight Switching • 10A SPDT relay output
• Temperature Control • DC or AC power supply option
• Soil Moisture Monitoring
• Remote Start/Stop

DPDT on request DPDT on request DPDT on request. No Solid State Output

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: (AC only - see SC130 for DC AC: Supply voltage: 12, 24, 115, 230,
applications) AC: Supply voltage: 12, 24, 115, 230, AC: Transformer (2kV galvanic 400, 415, 525 ±15%
Supply voltage: 12, 24, 115, 230, Isolation (sensor input to power supply):
400, 415, 525V AC ±15% 400, 415, 525V ±15% isolation): Supply Voltage: 12, 24, 2kV
Isolation (probe input to power Power consumption: 3VA, 6VA for 415,
supply): 2kV Isolation (probe input to power 115, 230, 400, 525VAC 525V (approx)
Power consumption: 3VA, 6VA for DC: Supply voltage: 10-30V, 48, 60, 110V
415, 525V (approx) supply): 2kV Power consumption: 2VA (approx) ±15%
PROBE INPUT Isolation: no galvanic isolation
Sensitivity: approx. 15-500k Ohm Power Consumption: 3VA, 6VA for 415, Tolerance: ±15% Power Consumption: 100mA (10-30V),
(adjustable) 30mA for higher ranges
Probe voltage: 12V AC 525V (approx) DC: Supply voltage: 48, 60, 110V SENSOR INPUT
Probe frequency: 50Hz Type NAMUR (DIN 19234)
DC: Supply voltage: 10-30V, 48, 60, Power Consumption: 30mA (approx) Maximum Sensing Speed: 25Hz
(when using relay output)
110V ±15% AC/DC: Supply Voltage: 12 - 24V Short Circuit Current: 20mA DC
Open Circuit Voltage: 8,2V DC
Isolation: no galvanic isolation Power Consumption:
OUTPUTS (SP)
Power consumption: 100mA (10-30V), 100mA (approx) NPN Open Connector (9,11)
Solid State Relay Drive (8,9)
30mA for higher ranges Tolerance: ±15% C/O (1,3,4)

LEVEL SENSING INPUT HOUSING If DP Contacts, no solid state O/P AUTOMATION PRODUCTS

Probe voltage: 4V AC 250V and below: 22,5mm width

Probe frequency: 100Hz Above 250V: 45mm width

Sensitivity: 0 - 50kOhm (adjustable) LEVEL SENSING INPUT

Response time: 0,5 seconds Probe voltage: 4V AC

Probe frequency: 100Hz

*For Probe parts, see page 48 Sensitivity: 0 to 100kOhm

(adjustable)

Response: 0.5 seconds

RELAY

Relay Contacts (250V, 5A): SPDT,

*Relay contact DPDT.
SP= Single Pole
DP= Double Pole *For probe parts see page 48

Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
Example SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
SC 100 SC 130 AC 130 SC 230
230V AC * 230V AC * 230V AC * 230V AC *

RHE 22

PROCESS CONTROLLERS

Type Control Module for Intrinsically Safe Control 3-Wire DC Sensor Interface Tachometer Relay
NAMUR Sensor
Module for NAMUR Sensor Relay Module

FFAEIALTSUARFEES FFAEIALTSUARFEES

Code SC300 SC301 SC314 SC320
Features
• Direct interface with Namur two- • Intrinsically safe classification: • Interfaces with all types of 3-wire • Direct interface with Namur
Connection wire proximity sensors (inductive, (Ex ib) Gr 2C, T6. NPN or PNP DC sensors two-wire proximity sensors or
Diagram capacitive and opto-electronic) • Direct interface with Namur two (inductive, capacitive and limit switches
• Sensor cable fault detection with wire proximity switches optoelectronic) • Low power sensor signal to
LED indication • Failsafe operation • LED indication of relay status DIN19234
• Proximity switching in hostile • Sensor cable fault detection and • Robust power supply • Sensor cable fault indication
supply voltage environments indication • Cost efficient interface for DC • Programmable speed ranges:
(transients, surges) • Low power sensor signal to sensors in AC environments 10 RPM to 10 000 RPM
• High reliability proximity switching DIN19234 • Cost efficient module replacement • Programmable for over-speed
compared to limit switches • SPST relay outputs • 10A SPDT relay output or under-speed detection
• Cost efficient sensor and module • 0 to 1mA proportional output
replacement for tachometer instruments
• Impervious to interference between • 4-20mA available on request
sensor and amplifier over long cable • Speed set point adjustable on
runs calibrated scale 0-100%
• Low power sensor signal to • Start-up delay
DIN19234 • 10A SPDT relay output
• 10A single pole or 2 x 5A double
pole relay outputs Note: Analogue output not
available when DP option selected

DPDT on request DPDT on request DPDT on request DPDT on request

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 115, 230V AC: Supply voltage: 12, 24, 115,
AUTOMATION PRODUCTS 230, 400, 415, 525V ±15% ±15% SUPPLY VOLTAGE 230, 400, 415, 525V ±15%
Isolation (sensor input to power Isolation (sensor input to power AC: Supply Voltage: 12, 24, 115, Isolation (sensor input to power
supply): 2kV supply): 2kV 230, 400, 415, 525V ±15% supply): 2kV
Power consumption: 3VA, 6VA for Power consumption: 3VA Isolation (sensor input to power Power consumption: 3VA, 6VA for
415, 525V (approx) approximately supply): 2kV 415, 525V (approx)
DC: Supply voltage: 10-30V, 48, DC: Supply voltage: 24V ±15% Power consumption: 3VA, 6VA for DC: Supply voltage: 10-30V, 48,
60, 110V ±15% Isolation: no galvanic isolation 415, 525V (approx) 60, 110V ±15%
Isolation: no galvanic isolation Power consumption: 100mA DC OUTPUT SUPPLY FOR Isolation: no galvanic isolation
Power consumption: 100mA (10- SENSOR INPUT SENSORS Power consumption: 100mA (10-
30V), 30mA for higher ranges Type: Namur (DIN 19234) 10-15V at 30mA 30V), 30mA for higher ranges
SENSOR INPUT Quiescent Voltage: <8.2V DC SENSORS INPUT: (PNP pin 5, SENSOR INPUT
Type: NAMUR (DIN 19234) Short circuit current: < 25mA NPN pin 8) Type: Namur (DIN 19234)
Maximum Sensing Speed: 25Hz Max External Capacitance: Each sensor must be able to Short Circuit Current: 20mA DC
Short Circuit Current: 20mA DC < 300nF (AC supply), < 700nF conduct at least 80mA to operate Open Circuit Voltage: 8,2V DC
Open circuit voltage: 8,2V DC (DC supply) the modules internal relay Hysteresis: 10% (fixed)
Max External Inductance: < 2mH Maximum switching speed: 25Hz Repeatability: 1%
Relay options: SPST (pins 1 & 3, Start-up delay: approximately 10
NO), DPST (pins 1 & 3 NO / pins 11 (when using relay output) seconds (Available 0-15 seconds
& 9, NO) on special order)
Maximum relay current: 5A Analogue output: 0-1mA DC**
Maximum relay voltage: 250V (0-20mA or 4-20mA - available as an
Maximum product of relay current output order option)
and voltage: 100VA Maximum load: 7k Ohm
Internal fuse rating: (AC supply) Accuracy: 5% of full scale
100mA, 250V
Speed Range Approximate
Response time

*Relay contact 10-100 RPM 10 seconds
SP= Single Pole 30-300 RPM 10 seconds
DP= Double Pole 100-1 000 RPM 1 second
300-3 000 RPM 1 second
1 000- 10 000 RPM 1 second

Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER OUTPUT RELAY
Example SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
SC 300 SC 301 SC 314 SUPPLY CONTACTS
23 230V AC * 230V AC * 230V AC SP
**SC 320 230V AC *

RHE

PROCESS CONTROLLERS

Type Opto-electronic Control Unit Temperature Control Module Thermistor Motor Protection Flip Flop Relay with/without

Module Memory

FFAEIALTSUARFEES FFAEIALTSUARFEES FFAEIALTSUARFEES

Code SC410/SC411 SC501 SC510/SC511 SC610/SC611
Features
• Directly interfaces with the R02 • Interfaces with industrial standard • Interfaces with PTC sensors as • Many power supply options
Connection Detector range of rectangular and PT-100 temperature sensors per DIN 44081 • Direct connection of a NPN
Diagram tubular opto-electronic sensors • Six programmable overlapping • The SC511 has a fault latching sensor (SC611)
• 10 metre sensing distance with the temp. ranges between -50 - 300°C feature, can be reset via external • SC610 - without memory
appropriate barrier heads • Programmable for over and under opening contact or via the reset • SC611 - with memory
• Programmable for dark or light temperature button on the unit • 10A SPDT or a 5A DPDT relay
response • Temperature level adjustment on • Test button to simulate fault
• Adjustable on and off response calibrated scale 0 - 100% condition on the SC511
delay of 0-5 seconds • High repetitive accuracy • Sensor or cable fault detection
• Signal modulated beam to stop • Programmable inversion of relay and indication with an automatic
foreign light source interference output for fail-to-safe operation relay de-energisation for failsafe
• Adjustable light intensity • 0 to 1mA proportional output for operation
• High speed solid state (NPN) open each temperature range • 10A SPDT relay output
collector output • Proportional output is limited to 1,2
• Direct interface with solid state relays mA to protect analogue instruments
• Opto sensor cable fault detection • Latching on under-temperature or
(SC411 only) over-temperature (programmable)
• 10A SPDT relay output • 10A SPDT relay output

Specifications See page 327 for sensors. DPDT on request DPDT on request .No Latching DPDT on request DPDT on request AUTOMATION PRODUCTS
POWER SUPPLY
*Relay contact (No Solid State Output) POWER SUPPLY POWER SUPPLY AC: Supply voltage: 12, 24, 115,
SP= Single Pole AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 12, 24, 115, 230, 400, ±15%
DP= Double Pole POWER SUPPLY 230, 400, 415, 525V ±15% 230, 400, 415, 525V ±15% Isolation (reset to power supply):
Ordering Code AC: Supply voltage: 12, 24, 115, Isolation (sensor input to power Power consumption: 3VA, 6VA for 2kV
Example 230, 400, 415, 525V ±15% supply): 2kV 415, 525V (approx) Power consumption: 3VA
Isolation (sensor input to power Power consumption: 3VA, 6VA for DC: Supply voltage: 10-30V, 48, (approx)
supply): 2kV 415, 525V (approx) 60, 110V ±15% DC: Supply voltage: 12, 24, 48,
Power consumption: 3VA, 6VA for DC: Supply voltage: 12, 24V 15% Isolation: no galvanic isolation 60,110V ±15%
415, 525V (approx) Isolation: no galvanic isolation Power consumption: 100mA for Isolation: no galvanic isolation
DC: Supply voltage: 10-30V, 48, ±15% Power consumption: 100mA 10-30V, 30mA for 48V and higher Power consumption: 100mA for
Isolation: no galvanic isolation CONNECTION CABLE SENSOR INPUT 12V and 24V, 30mA for 48V and
(common negative) 2 - core, unscreened. Resistance of Type: PTC sensor as per DIN 44081 higher
Power consumption: 100mA long cables affect temp. accuracy Input impedance: 2200 Ohms 12V DC Output:
(10-30V), 30mA for higher ranges (Approx.1°C per 0.3 ohms) Open-circuit voltage: <=2.5V Voltage tolerance: 10-15V DC.
RESPONSE SENSOR INPUT Short circuit current: 1mA (max) Source Current: 50mA (max.)
ON - Delay = 0.03 - 5 seconds Type PT-100 resistive temperature MEASURING
(adjustable) sensor CHARACTERISTICS OF THE INPUT
OFF - Delay = 0.03 - 5 seconds Short-circuit current: 1mA SENSOR
(adjustable) Open-circuit voltage: 220mV Maximum cold resistance of PTC SC-610
SOLID STATE RELAY OUTPUT TEMPERATURE SENSING sensor: 1500ohms (i.e. 1 to 6 Short circuit current: 8.5mA
(Pin 8-9) RANGE - Repetitive accuracy: 1% sensors can be connected)
Max. output source current: 8mA Triggering threshold: 3100 Ohms Open Circuit Voltage: 8.2V
Open circuit output voltage: 12V DC RANGE S1 ±10%
TRANSMITTER ( Pin 6 - 7) Recovery threshold: 1650 Ohms Input reset speed: 20 millisecs.
Current pulse: 1.5A/25 microseconds -50 to 50 C 1 ±10%
Maximum wire impedance: 2,5 0 to 100 C 2 Short-circuit detection: < 20ohms SC-611
Ohms (use coaxial cable) 50 to 150 C 3 Open-circuit detection: 10k ±10% Short circuit current: 1mA
Short circuit current: 20 mA (average) 100 to 200 C 4 Repetitive accuracy: 0,5%
RECEIVER (Pin 5 - 6) 150 to 250 C 5 Response Time: 50 milliseconds Open Circuit Voltage: 8.2V
Short circuit current: 3mA 200 to 300 C 6
Open circuit voltage: 8.2V Input reset speed: 10 millisecs.
OPEN COLLECTOR ANALOGUE OUTPUT
TRANSISTOR OUTPUT (Pin 9-11) Rating 0 to 1mA (proportional)
Type: NPN transistor 4-20mA available as an order option
Output sink current: 100mA on any one range
Maximum voltage: 30V DC Maximum voltage between pins 7
and 11 (pin 11 positive): 12V DC
Maximum load: 7k Ohm. Current
limits at 1.2mA to protect analogue
instruments

TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS
SC 410 SC 501 SC 510 SC 610
230V AC * 230V AC * 230V AC * 230V AC *

RHE 24

COUNTALINE

Type Power Supply Module Totalising Counter Multi-function Preselect Preselect Counter
Counter

Code SC900 CC120 SC700 CC701
Features
• Cost effective power supply. • Large 6-digit LED display with leading • High & low speed inputs in one unit • High & low speed inputs in one unit
Connection • A large variety of output supply zero suppression • Selectable ADD, SUBTRACT or • Relay hold time programmable from
Diagram options (see table below) • High speed count input (5kHz) with ADD/SUBTRACT count modes 0,1 - 25 seconds in 0,1 second
• High input voltage ranges (up positive or negative active edge (order • Relay hold time programmable increments
to 525V AC) option) from 0,1 - 25 seconds in 0,1 • Reset achieved via the front panel
• Ease of installation due to • Independent low speed count input seconds increments push-button, via external switch or
11-pin plug-in concept (30Hz) suitable for mechanical sensors • Reset achieved via the front via NPN sensors
• Reset achieved via the front panel panel push-button, via external • DC (NPN or PNP) or Namur
push-button, via external switch or via switch or via NPN sensors sensor compatible high speed input
NPN sensor • DC (NPN or PNP) or Namur (order option)
• Gate input for ignoring high speed count sensor compatible high speed • Large 4-digit display with leading
input pulses and gate inputs (order option) zero suppression
• DC (NPN or PNP) or Namur sensor • Tamperproof keylock feature for • Separate up and down count inputs
compatible high speed and gate inputs protection of programmed in ADD/SUBTRACT mode 1
(order option) parameters • Separate count and count direction
• 48 x 72mm panel mount housing format • 11-pin plug-in format (Industrial input in ADD/SUBTRACT mode 2
Standard) • User friendly keypad programming
• 48 x 48mm (1/16 DIN) panel
mounting housing format

AUTOMATION PRODUCTS Specifications INPUT SUPPLY VOLTAGE INPUT SPECIFICATIONS INPUT SPECIFICATIONS INPUT SPECIFICATIONS
AC: Supply Voltage: 12, 24, 115, Namur: High Speed & Gate Input: AC/DC: Supply voltage: 24V ±15% High speed input:
Ordering Code 230, 400, 415, 525V 10% Namur sensor DIN 19234 Isolation: No galvanic isolation Namur: Namur sensor DIN 19234
Example Isolation ( input to input): 2kV Reset Input: Potential free contact/NPN sensor Power consumption: 100mA DC: NPN or PNP sensor
Power consumption: 6VA (approx) Slow Speed Input: Potential free contact Low speed input: Maximum input frequency: 500Hz
25 OUTPUT SUPPLY VOLTAGE or NPN sensor Input type: potential-free contact or NPN Minimum pulse width: 1 millisecond
Type: AC, DC, DCRG DC: High Speed & Gate Input: NPN/PNP sensor sensor Active pulse edge: Positive or Negative
Output Voltage: 12, 24, 36 Reset Input; Potential free contact/NPN sensor Maximum count frequency: 30Hz Slow speed input:
AC Supply (±10%) Output Slow Speed Input: Potential free contact Minimum pulse width: 16.7ms Namur & DC: Potential free contact or
Current: 300mA, 150mA,100mA or NPN sensor High speed input: NPN sensor (open collector type)
DC Unregulated (±10%) Max. Input frequency: High Speed Input: 5kHz Maximum count frequency: 1kHz Maximum input frequency: 30 Hz
Output Current: Gate & Reset Input: 1kHz Minimum pulse width: 500Hz Minimum pulse width: 16.7 ms
200mA, 120mA, 100mA Slow Speed Input: 30Hz RESET INPUT Active pulse edge: Positive or Negative
% Ripple: <5 Minimum pulse width: High Speed Minimum pulse width: 500ms RESET INPUT: Namur & DC: Potential
DCRG Regulated (±1%) Input: 100 microseconds SENSOR INTERFACE free contact or NPN sensor
Output Current: Gate & Reset Input: 500 microseconds Replace * with sensor type Maximum input frequency: 500Hz
150mA, 100mA, 80mA Slow Speed Input: 16.7microseconds *D= PNP/NPN Minimum pulse width: 1 millisecond
% Ripple: <0,5 Active pulse edge: *N= Namur Active pulse edge: Negative: holds count
High & slow Speed Input: Positive or Namur: 8.2V DC/ 10mA value. Positive (if low for < 2 sec): resets
*Add to code output type negative, Namur and DC DC (NPN/PNP):12V DC/ 50mA count value and clears error messages
AC = AC Gate Input: Low level on input Max. NPN sensor saturation voltage: 2VDC SENSOR INTERFACE
DC = DC (UNREGULATED) SENSOR INTERFACE OUTPUT SPECIFICATIONS Replace* with Sensor Type
DCRG = DC (REGULATED) Replace* with sensor type Solid state relay: 12V at 10mA *D= PNP/NPN
1= Namur negative edge GENERAL SPECIFICATIONS *N= Namur
2= Namur positive edge Supply voltage: Replace** with Namur: 8.2V DC / 10mA
3= Negative - NPN/PNP(DC) 12VDC, 24VAC/DC, 115VAC, 230VAC, NPN or PNP sensor: 12V DC/ 30mA
4= Positive - NPN/PNP(DC) 400VAC, 415VAC, 525VAC Max.NPN sensor saturation voltage: 2V
Maximum count frequency exceeded: DC, 2.5V DC
Namur option: 8.2V DC/10mA 3 decimal points illuminating Maximum PNP sensor saturation
DC (NPN or PNP) option:12V DC/ 50mA Power supply interruption < 1 second: voltage: 2V DC (high speed count input)
Max. NPN saturation voltage: 2V DC 3 decimal points flashing OUTPUT SPECIFICATIONS
(high speed count and gate inputs)2.5V Relay ON time: Adjustable range: Relay: 250 VAC, 8A, SPDT
DC (low speed count input) 0.1 to 25 seconds SSR Drive: 10mA at 6V
Max. PNP sensor saturation voltage: 2V Resolution: 0.1 second repeatable ±1% GENERAL SPECIFICATIONS
DC (high speed count and gate inputs) Set-up and data retention: ±10 years Supply voltage: Replace** with
GENERAL SPECIFICATIONS 12VAC, 12VDC, 24VAC, 24VDC, 48VAC,
Supply voltage: Replace ** with 24VAC/DC, 115VAC, 230VAC, 400VAC
110VAC,230VAC, 400VAC, 415VAC, 525VAC
Protection class : IP 54 (front), IP30 (rear)
Connection: Plug-connector

AC OUTPUT OUTPUT TYPE MODEL ACTIVE POWER TYPE MODEL VOLTAGE SENSOR RELAY TYPE MODEL VOLTAGE SENSOR RELAY
TYPE MODEL VOLTAGE VOLTAGE TYPE EDGE SUPPLY TYPE CONTACTS TYPE CONTACTS
SC 700 * *
SC 900 * ** CC 120 * ** * SP CC 701 * * * SP

RHE

DIN RAIL MOUNT TIMERS

Type Delay on Timer Multifunction Timer Star Delta Timer Passage Light Timer Unequal Cycling Timer

(Replace *
with relay
type.)

(Replace *
with supply
voltage.)

Code ZHRT1-A - */ * ZHRT1-M - */ * ZHRT1-ST/ * ZHRT1-LS/ * ZHRT1-S2-/ *
Output
Replace * in Code with Replace * in Code with 2 x NO 1 x NO 2 x C/O
Relay *2 = 2 x Timed C/O *2 = 2 x Timed C/O
Rating *2T = 1 x Timed + 1 x *2T = 1 x Timed + 1 x
Function Instantaneous C/O Instantaneous C/O

5A@250VAC 5A@250VAC 5A@250VAC 10A@250VAC 5A@250VAC

• Microprocessor based • Microprocessor based • Microprocessor based • Microprocessor based • Microprocessor based
• LED indication of supply • LED indication of supply • LED indication of supply
and relay state and relay state and relay state. • Control of stairwell • LED indication of supply
• On application of power • 10 Independant operating • Start time adjustable
the time function starts. functions: 1s - 10min. or Passage Lighting and relay state
At the end of time delay A - Delay on operate • Pause time adjustable
the relay operates B - Delay on Release 20ms - 300ms. • When the unit receives a • Time ranges from 0.1s to
• The unit is reset by removal C - Cycle timer OFF first • The unit is reset by removal
and re-application of power D - Cycle timer ON first and re-application of power pulse input (L/N) the relay 100Hr
supply E - Interval hold reset supply
• Wide time range of F - Interval pulse reset operates for the preset time. • Timing Functions start on
0.1s to 100Hr G - Delay OFF hold reset
H - Delay ON/OFF pulse At the end of the set time it application of power supply.
reset
I - Latching pulse reset switches of automatically. • The unit is reset by removal
J - Pulse Generator
• Wide time range of • LED indication of supply and re-application of power
0.1s to 100Hr
and relay state supply.

• Auto or Manual Mode

• Time Range adjustable:

30s - 20min

Supply *D12 = DC12V *D12 = DC12V *A110 = AC110V *A110 = AC110V *AD240 = AC/DC 24-240V
Voltage *AD240 = AC/DC 24-240V *AD240 = AC/DC 24-240V *A230 = AC230V *A230 = AC230V *A110 = AC110V
*A400 = AC400 *A400 = AC400V *A400 = AC400V *A400 = AC400V *A400 = AC400V
Diagram

AUTOMATION PRODUCTS

RHE 26

VOLTAGE MONITORS

Type 3 Phase 3 Phase Over and Under 3 Phase 3 Phase
Phase Failiure/ Over/Under Voltage, Voltage Monitor Over/Under Voltage, Phase Sequence/
Over or Under (Comparator) Failure/Asymmetry
Sequence/ Phase Sequence/ Voltage Monitor Phase Sequence/
Asymmetry Failure/Symmetry Failure/Symmetry

(Replace *
with supply
voltage.)

Code ZHRV3-01-Z/ * ZHRV3-07-Z/ * ZHRV5-01/ * ZHRV5-02/ * ZHRV5-09/ * ZHRV5-11/ *
Output
2 x C/O 2 x C/O 1 x C/O 1 x C/O 1 x C/O 1 x C/O
5A@250VAC 5A@250VAC 5A@250VAC 5A@250VAC 5A@250VAC 5A@250VAC

Function Phase Sequence/Failure Phase Sequence/Failure Selectable Operating Over & Under Voltage Phase Sequence/Failure Phase Sequence/Failure
Overvoltage 2-20% Asymmetry 8%
Asymmetry 5-15% Overvoltage 2-20% Modes: Levels adjustable Undervoltage 2-20% Trip Delay 2s
Asymmetry fixed 8%
Trip Delay 0.1-10s Undervoltage 2-20% - Over Voltage Latching (Dependant on supply Trip Delay: 0.1-10s • Microprocessor based
• True RMS measurement
Reset Time 0.1-10s Asymmetry 5-15% - Over Voltage Non- voltage). • Microprocessor based • 8 Nominal voltage
• True RMS measurement
Trip Delay 0.1-10s Latching Fixed Hysteresis: 5% • 8 Nominal voltage Operating Ranges
• Frequency Range:
Reset Time 0.1-10s - Under Voltage Latching Time Delay: 0.1-10s Operating Ranges
• LED status indication. 45-65Hz
- Under Voltage Non- • LED status indication
*M460 = AC 220V-440V
Latching (8 Set Points-P/P) *M460 = AC 220V - 440V
Frequency Range (8 Set Points-P/P)
• Microprocessor based • Microprocessor based • Voltage threshold • Microprocessor based 45 - 65Hz Frequency Range
45 - 65Hz
• True RMS measurement • True RMS measurement adjustable (Dependant • True RMS measurement

• 8 Nominal voltage • 8 Nominal voltage on Supply Voltage) • Monitor AC or DC

operating ranges operating ranges • Hysteresis: 5-20% • LED indication of

• LED status indication • LED status indication •Time Delay: 0.1-10s control state.

• Trip/Reset delay • Trip/Reset delay • Microprocessor based

adjustable adjustable • True RMS measurement

• Suitable for either 3 • Suitable for either 3 • Monitor AC or DC.

or 4-Wire systems or 4-Wire systems • LED indication of

control state.

*M440 = AC 208V-440 *M440 = AC 208V-440 *D12 = DC12V *D12 = DC12V

(8 Set Points-P/P) (8 Set Points-P/P) *AD48 = AC/DC 24-48V *AD48 = AC/DC 24-48V

*M254 = AC 120V-254V *M254 = AC 120V- 254V *AD240 = *AD240 =

(8 Set Points-P/N) (8 Set Points-P/N) AC/DC 110-240V AC/DC 110 - 240V

Frequency Range: Frequency Range:

45 - 65Hz 45 - 65Hz

AUTOMATION PRODUCTS ZHRV3-01-Z/M245 - 4 Wire

ZHRV3-01-Z/M440 - 3 Wire RHE

27

MOTOR PROTECTION RELAYS LIQUID LEVEL CONTROLLER

Type Motor Protector Type Liquid Level Control

(Replace * (Replace *
with trip with supply
current) voltage)

(Replace *
with supply
voltage)

Code ZHRA1-*/ * ZHRA5-* Code ZHRL1-A/*
Output Output
Function 1 x C/O 1 x N/C 1 x C/O
5A@230VAC 1A@240VAC [email protected]
Supply
Voltage Inverse time current protection, over- Does not require power supply. Function Charge and Discharge. (Fill & Drain)
load, phase failiure, phase assymetry Simplified wiring & installation. Adjustable Sensitivity: 5kΩ - 100kΩ.
and locked rotor protection. Overload, Phase Failure Protection Supply Can operate as 2 or 3 probe system
LED Indication of status Thyristor Output. Voltage Adjustable delay to prevent false triggers: 0.1-10s
Current transformers integrated into LED Indication of status. Connection LED indication of high/low water level
the body of the unit. Compact design. Low Cost. Diagram
Current transformers integrated into *A110 = AC 110V
Various Current Ranges available: the body of the unit. *A230 = AC 230V

Trip Current Motor Kw Various Current Ranges available: 3-Wire (Drain)
Trip Current
*1A-5A 0.5 - 2.5kW *0.5A - 5A
*2A - 20A
*6A-30A 3 - 15kW *20A - 80A
*64A - 160A
*16A-80A 8 - 40kW

*80A-400A 40 - 200kW

Current adjustable within range.
Adjustable start Delay: 2-30s

3-Wire (Fill)

*AC230V No power supply required
*AC400V
Frequency Range 45 - 65Hz

Connection
Diagram

2-Wire (Drain)

Direct Start with AC230V 2-Wire (Fill) AUTOMATION PRODUCTS

contactor. For other configurations 28
see product data sheet.

RHE

SPECIAL PRODUCTS

Type 3-Phase Current Monitor Re-cycling Timer Control Module for Semi-Automatic Spark Detector
with Pause Namur Sensors Synchronising Unit

FFEAAITLUSARFEES

Code CM193 DT310/12 PSM1130/3 SAS110 SP08M
Features
• Ready to operate when the • Unit starts with pause • Transistorised switching • Senses differences in voltage, • Detects infra light from arcing or flames
Connection
Diagram current transformers and shunt mode amplifier for inductive proximity, frequency and phase angle • Long dist. sensing and acc. location
resistor block-SR3 is connected • Contacts totally isolated sensors to DIN19234 (Namur) between the generator and the • Cost effective solutions, detection in
• When power is applied the • Adjustable pause time • Available as a solid state or busbar system burners, boilers or fire detection equip.

relay energises immediately ranges relay output • LED illuminates when all 3 • In conjunction with a suitable infra light

• LED indication showing • Adjustable cycle time • Selectable delay on output parameters match source, a high speed opto-barrier syst.

power ON ranges • Programmable for metal • Hysteresis setting for voltage • Syst. consists of a Control Unit SP-08M

• If the current on any of the 3 • Whole cycle will sensing and non metal sensing • Response delay 0,3 to 3 secs & side or front sensor heads SP-08S

phases fails below the set limit continuously • LED indication for metal • Adjustable voltage • Initiates power shut down before

for at least one second, the repeat until power has sensed or no metal sensed synchronisation point, permanent damage is done

relay will de-energise and the been switch off • LED indication when relay is 5-30V RMS • The sensor heads can be connected in

LED extinguishes energised parallel and any sensor will trigger

the relay output

• The module can be configured to latch

when arcing is sensed

SPDT AC or DC AC
DPDT POWER SUPPLY

POWER SUPPLY SUPPLY VOLTAGE

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 115, 230,
Ordering Code 400, 415, 525V ±15% AC: Supply voltage: 48, AC Transformer: Supply Voltage: AC: Supply voltage:115, 230, AC: Supply Voltage: 12, 24, 115, 230,
Example Power consumption: 3VA
(approx), 6VA for 415, 525V 60, 115, 230, 400, 415, 12, 24, 48, 60,115, 230V ±15% 400, 415, 525V ±15% 400V
29 (approx)
Isolation: no galvanic isolation 525V ±15% Operating frequency: 40-60 Hz Power consumption: 3VA, 6VA Power Consumption: 3VA(approx)
Shunt resistor block - SR3 - Power consumption: 3VA Isolation test voltage: 2KV
1Amp or 5 Amp (approx), 6VA for 415, Power Consumption: 2,5VA for 415, 525V (approx) Isolation: 2kV (voltage input to power

GENERAL Over voltage protection: 50% supply)Tolerance: ±15%
Weight: 190g Overvoltage protection: 50% for for 1 minute
Colour: Blue 525V (approx) 1 min(50Hz)

DC: 24V only. DC: Supply Voltage: 24V, ±15% Red Phase: protection: 750V GENERAL
Max. ripple: 100% (above 50Hz) Over voltage Weight: 190g
GENERAL Power Consumption: approx. 1,5W Colour: Blue
Weight: 190g
Colour: Blue Overvoltage protection:100% for GENERAL Sensor Head, to be ordered separately
1 min. on 24VDC
Rating for continuous op.:100% ED Weight: 200g
Colour: Blue
Voltage stabilisation: Yes

AUTOMATION PRODUCTS PAUSE TIME RANGES Transient protection: Yes
Operating temp.: -20 to +50℃
0,1 - 2 sec 1 - 20 min Supply interruptions: Will not react
0,3 - 6 sec 3 - 60 min to interruptions less than 30ms
1 - 20 sec 10 - 200min TIMERS:
3 - 60 sec 0,5 - 10 hrs Input pulse length: 0,1 to 5 secs
10 - 200 sec 1 - 20 hrs Output hold time: 0,1 to 5 secs
30 - 600 sec 1 - 30 hrs Repeatability: approx. 1%

CYCLE TIME RANGES Overall accuracy: approx. 5%
OUTPUT
0,1 - 2 sec 1 - 20 min Relay contact: 1x single pole
0,3 - 6 sec 3 - 60 min change over contact Front sensing - SP08F
1 - 20 sec 10 - 200min Contact rating (resistive load): Side sensing - SP08S

3 - 60 sec 0,5 - 10 hrs 380VAC - 10A - 2500VA
10 - 200 sec 1 - 20 hrs Contact isolation:2500V
30 - 600 sec 1 - 30 hrs SOLID STATE

*Relay contact Type: Open collector transistor

SP= Single Pole Output sink current: 100mA/12VDC

DP= Double Pole GENERAL

Weight: 190g Colour: Blue

RELAY TYPE RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER
TYPEMODEL SHUNT VOLTAGE POWER CON- MODEL VOLTAGE POWER CON- SUPPLY CONTACTS SUPPLY SUPPLY
1130/3 SAS 110 SP 08M
SUPPLY TACTS SUPPLYTACTS 230V AC SP 230V AC 230V AC

DT 301/12 230V AC
CM 193 * * * *AC PSM

RHE

TIME SWITCHES

Orbis Digital Time Switches

Code No. of Time Total No. of Working Minimum Width in Relay

channels Range programmes Reserve Interval DIN Output

DATALOG1† 1 24hrs/7days 50 on + 50 off 5 years 1 sec 2 16A,C/O
DATALOG2† 2 24hrs/7days 50 on + 50 off 5 years 1 sec
MINITLOG† 1 24hrs/7days 50 on + 50 off 5 years 1 sec 2 16A,C/O

Panel Mount 16A,C/O
72 x 72

†Specify voltage with order: 230VAC, 110VAC, 24VAC/DC. 12VAC/DC.

Features Lamp Loads

DATALOG MINITLOG • Programming with text menus Incandescent lamps 3000W
• Output pulse 1-59 secs programmable Uncompensated fluorescent 1200W
• R andom programming for security lighting LV Halogen 1000W
• Running hour counter 230V Halogen 2500W

Economy Digital Time Switch

Code No. of Time Total No. of Working Minimum Width in Relay

channels Range programmes Reserve Interval DIN Output

TH-857-2 * 1 24hrs/7days 8 on + 8 off 200hrs 1 min 2 16A,C/O

*Add Voltage to code: 230VAC, 110VAC, 24VAC/DC. 12VAC/DC.

Factory / School Time Switch

Code Description

FTDE7 Complete with digital time switch in IP55 Gewiss (GW40001) enclosure
VP-PROG 170 x 105 x 98mm. Programmable 50 On + 50 Off settings per week and block programming which
enables programs to be repeated for each weekday or 6 or 7 days. Duration of siren can be set from
1 to 59 sec. Supply: 230VAC. Relay Output: C/O 16A @ 250VAC. Reserve: 5 years
Features as per DATALOG1

Programming Charge for FTDE7 Timer

For complete range of Audible &Visual Alarms see pages 333-353.

Bluetooth Connectivity for Panel Fitted Daylight Switch
IOS4s/Android 4.0 & above
Code ASTRO NOVA

Accessory - Bluetooth Dongle OB709971

Power Supply 230VAC (6VA) Astro Nova fits inside your distribution
Switching Capacity 16(10)A/250V AC 2C/O board. Enter in your co-ordinate or city
Operating Accuracy and it will control your lights perfectly!
Switching Accuracy ±1sec/day at 23°C
Battery Back-up Better than 1 second
Memory Spaces 10 years (Lithium battery)
Auto change summer/winter
Max Recommended Load 22
Incandescent Yes
Non-compensated Fluorescent
3000W
1200W

Digital Time Switches

Code No. of Time Total No. of Working Minimum Width in Relay
channels Range programmes Reserve Interval DIN Output

Annual / Monthly / Weekly / Daily Time Switch 16A,C/O

VE3406 1 D/W/M/Y 30 on + 30 off 3 years 1 Min 2

• Supply Volts: 230VAC AUTOMATION PRODUCTS

Features as per DATALOG1 but with additional programming:

Monthly – every month on the same day.

Annual – every year in the same month and on the same day, at a preset date during the year.

4 Channel Annual / Monthly / Weekly / Daily Time Switch

VP8692 4 D/W/M/Y 100 on + 100 off 5 years 1 Min 4 16A,C/O

VE3406 VP8692 Supply Volts: 230VAC & 24VAC/DC

Geyser Controller with Embedded Microprocessor

Geysers are the largest user of electricity in most households using up
to 60%. GC-100 geyser controller will save 40%-60% of geyser usage.

Code GC-100 Technical Info
Features
• Immediate saving from first monthly bill. • Input Voltage: 220/240VAC 50Hz
• Ensures geyser is off during peak periods • Mounting: Din Rail
• Back-up battery to retain memory • Memory: 120 day battery
• Override switch geyser off and on • Current Sensor: 20Amps
• 8 Pre-programmable time periods • Relay output 20A

DOPRM1 30

24 Hour TIME SWITCHES 7 Day
2G0feoAyrsers
• Easy to program DIN Rail Electronic Time Switches
• Manual ON/ OFF/ AUTO override 7 Day
• LCD Display with backlight

Code DHC20 DHC15A DHC15A-20A
No of Channels
Time Range 1 1 1
No of Programs 24 Hours 24 Hours / 7 Days 24 Hours / 7 Days
Working Reserve 48 On / 48 Off
Minimum Interval 150 Hours 8 On / 8 Off 8 On / 8 Off
DIN Width 15 min 150 Hours 150 Hours
Relay Output 3 Modules
SPDT 16A 1 min 1 min
TS-MS1 2 Modules 2 Modules
SPDT 16A SPDT 20A
31
Electronic School Timer

Code No. of Time Total no. of Working Minimum Width in Relay
channels Range programmes Reserve Interval DIN Output

SDM-10/U 1 24hrs/ 50 on + 50 off 3 years 1 sec 2 16A, C/O
7 days

Features • Complete with protective flap.
• Supply Voltage: 24V - 230VAC/DC
• User friendly, and easy to program. Lesson times can • Relay output rated at 16A, AC1 rating
easily be added or changed. The controller has a real • Battery backup, preventing data loss during power failure
time clock and calendar. • LED illumination of the LCD display
• Able to back up programmed times for 10 years
• Adjustable ringing duration
• Width: 35mm (2 Module width) • Seasonal and holiday programming available
• Not more than 120 minutes between bells

Electronic School Control Box

Code Description Features

EW-01 The Electronic School Janitor is an assembled unit. Two ways of connecting directly to the school bell

Used for controlling school utilizing the SDM-10. or connecting to the existing installation instead

It consists of: of manually ringing the bell.

• Over Voltage Protection • Easily programmable timetable.

• Bell Controller (SDM-10) • Real time clock.

• Electromagnetic Relay x 2 • Adjustable ringing duration.

• Alarm Button • Programmable alarm bells.

• Accoustic Alarm Indicator • Seasonal and holiday programming available

• Short period selection button

Astronomic Weekly Timer / Daylight Switch - 230VAC
Just program in your geographical co-ordinates and the unit will do the rest.
Can also use a photocell to give additional control.

Code Description Relay Output

AUTOMATION PRODUCTS DTR-14 Astronomic timer with photocell 2C/O (8A)
DTR-10 Astronomic timer 2 C/O (8A)
DTR-10T Astronomic timer 1 C/O (16A)
FG-GOZ Photocell sensor for DTR-14 –

• Battery back-up: 5yrs. Connection Diagram
• Super capacitor for additional 10hrs reserve
• No. of programs: 15
• Operating accuracy: ≤1 sec/day.

Plug In-Mains Timers

Code Dial Working Minimum Contact
Reserve Setting Rating
TS-MS1 24h
TS-MS2 7 day – 30 min 16A
TS-30 7 day digital – 1 hr 16A
100 hrs 1 min 16A

TS-MS2 TS-30

OR1

TIME SWITCHES

battery Supra Type
SUPRA
Code TTyyppee MMoototorr Dial Working Minimum No of CCoonnttaaccttRRaattiinngg
Reserve Switching Mod @@223300VV
time
SD Supra D Synchronous 1 x 24h – 15min 2.5 16A
SQRD Supra QRD 100hrs 15min 2.5 16A
Quartz 1 x 24h 100hrs 2hrs 2.5 16A
– 30min 2 16A
SQRS Supra QRS Quartz 1 x 7 day

DUOD Duo D Synchronous 1 x 24h

New design includes replaceable battery from front

DUO Spare Battery Code 54225
UNO
Uno & INCA DuoType

Code TTyyppee MMoottoorr Dial Working Minimum No of Contact Rating
Reserve Switching Mod @ 230V
time
INCA UD Uno D Synchronous 1 x 24h – 15min 1 16A
UQRD Uno QRD Quartz 1 x 24h 100hrs 15min 1 16A UNO
UQRS Uno QRS Quartz 1 x 7 day 100hrs 2hrs 1 16A
DD INCA D Synchronous 1 x 24h – 15min 2 16A
DQRD INCA QRD Quartz 1 x 24h 100hrs 15min 2 16A INCA
DQRS INCA QRS Quartz 1 x 7 day 100hrs 2hrs 2 16A

Defrost (Refrigeration) Time Switches

Code Type Defrost Duration Time between Defrost Contact Rating
16A
FRI-60 FRI 5-50m Minimum 2 hours

Ideal for freezer rooms where fan delay is required

Alpha Type

Code Type Motor Dial Working Minimum Contact
Reserve
– Switching time Rating @ 230V

AD Alpha D Synchronous 1 x 24h 100hrs 15min 16A
AQRD Alpha QRD
AS Alpha S Quartz 1 x 24h – 15min 16A
AQRS Alpha QRS
Synchronous 1 x 7 day 100hrs 2hrs 16A

Quartz 1 x 7 day 2hrs 16A

Crono Type – DIN Mount or Panel Mount 72 x 72mm

Code Type Motor Dial Working Minimum Contact

Reserve Switching time Rating @ 230V

CQRD Crono QRD Quartz 1 x 24h 100hrs 15min 16A

CQRS Crono QRS Quartz 1 x 7day 100hrs 2hrs 10A

CDD Crono DD Synchronous 2 x 24h – 30min 15min 10A CRONO D, QRD, S, QRS

CQRDD Crono QRDD Quartz 2 x 24h 100hrs 30min 15min 10A

CQRSD Crono QRSD Quartz 1 x 24h & 1 x 7day 100hrs 2hrs 20min 16A CRONO DD, QRDD, QRSD, SM

Swimming Pool Timer

Code TDyiaple RWMeoosretkorinvr eg SMDeintitaiimnl gum Woidrtkhining tSMimwRinieeitmcsChiusoimntnigvteacNMtooRIdonafdtiuncgC@toiv2ne3ta0cVt RAaCtinSgupply AUTOMATION PRODUCTS
TB-17 24h - DReINserve

30min 2 15A 10A 240VAC

Replaceable battery Economy Time Switches

Code Dial Working Minimum Width in Contact Spare
Reserve Setting DIN Rating Battery
15min 3 16A VB80H2A6H
SUL181D 24h 200h
30min 1 16A -
BND-X5 24h 15h

Ideal for swimming pool pump control

SUL181D BND-X5

OR1 32

ELECTRONIC TIMERS

Type Multi-Function Timer Delayed ON / Interval
(One Shot) Timer

Code 48T100 48T101 A-LINE & PUMP MONITOR
Features PROTECTION HOUSING
• Microprocessor based • Microprocessor based
Connection • Power On LED indication • Power On LED indication Clips for Slimline
Diagram • Relay operation LED indication • Relay operation LED indication consists of 10 sets
• Programmable functions: • Time Range 0.1s to 100hrs
Specifications Delay on (Pulse start); Interval (Hold/ • DPDT relay (5A) as standard RMC
Pulse Start); Equal • Flashing Power LED when timing
Ordering Code Repeating (On/Off First); Signal On/ • 5 Sec Test Mode to confirm circuit 10 Sets / Pack
Example Off Delay operation and assist
• Start - Reset - Gate Inputs commissioning
33 • Gate Input: When activated the unit • Front dial doubles as screwdriver
stops timing and continues when for adjusting controls
released
• Time Range 0.1s to 100hrs
• DPDT relay (5A) as standard
• Flashing Power LED when timing
• 5 Sec Test Mode to confirm circuit
operation and assist commissioning
• Front dial doubles as screwdriver for
adjusting controls

45
36

27
18

~~
-+
Power Supply

Available in 8 or 11 Pin Format

AUTOMATION PRODUCTS Power Supply: Power Supply:
AC Reactive: AC Reactive:
Supply Voltage: 230 (100-230VAC) Supply Voltage: 230(100-230VAC)
Power Consumption: 3VA Power Consumption: 3VA
AC/DC: AC/DC:
Supply Voltage: 24(24VAC/DC) Supply Voltage: 24(24VAC/DC)
DC: DC:
Supply Voltage: 12VDC Supply Voltage: 12VDC
Power Consumption: 1.5W Power Consumption: 1.5W
Tolerance: ±10% Tolerance: ±10%
Reset Times Reset Times
Input Reset: 50msec min Input Reset: 50msec min
Power Reset: 100msec min Power Reset: 100msec min

Timing Settings Timing Settings

Range Scale Multiplier Range Scale Multiplier

Sec X1 X10 Sec X1 X10
Min Min
Hrs 0.1- 1sec 1 - 10sec Hrs 0.1- 1sec 1 - 10sec
10Hrst 0.1 - 1min 1 - 10 min 10Hrst 0.1 - 1min 1 - 10 min
0.1 - 1hrs 1 - 10 hrs 0.1 - 1hrs 1 - 10 hrs
1 - 10hrs 10 - 100hrs 1 - 10hrs 10 - 100hrs

General Specifications: General Specifications:
Enclosure protection rating: IP40 Enclosure protection rating: IP40
Size: 48 x 48 x 67 Size: 48 x 48 x 67
Weight: ± 100gm (approx) Weight: ± 100gm (approx)
Only 11Pin *Add to code 08 = 8Pin
*Add to code 11 = 11Pin

TYPE MODEL TYPE VOLTAGE TYPE MODEL TYPE VOLTAGE

48 T100 11 230V 48 T101 * 230V

RHE

SPECIAL TIMERS

Type Multi-Range Function Multi-Range Timer Digital Setting & ­ Multi-Range Miniature Timer
Multi-Voltage Timer Multi-Voltage Display (4 Digit) 4 Digit Timer

Code AT11DN (2 delay) AH5N (1S-600H) AH5F SP3-48 AMY-2**
Relay Contacts
Operation AT11EN (1 Del + 1 Inst) AH5N-S (6S-60min) 5A @ 250VAC 5A @ 250VAC 5A @ 250VAC
Delay On SPDT &
Size 3A @ 250VAC 5A @ 250VAC instantaneous SPDT Delay On Delay on operate
Time Range Up/Down timing Contacts: DPDT
• Delay On Mode A Delay On DPDT Start/Reset mode
Supply Voltage • Delay Off (interval) Mode B Delay On SPDT Programmable
Connection • Delay On pulse start & instantaneous SPDT power-off memory
Diagram • Delay Off pulse start
• Equal repeating On or

Off first
AT11DN (2 delay SPDT)
AT11EN (1 delay + 1
instantaneous SPDT)

48 x 48mm Panel Mount 48 x 48mm Panel Mount 48 x 48mm Panel Mount 48 x 48mm Panel Mount 22 x 28mm Base Mount
Base required (ZM2VP)
or 11 PIN.Base Mounting or 8 PIN. Base Mounting or 8 PIN Base Mounting or 8 PIN Base Mounting
*6 sec
bracket included bracket excluded.(Y-50) bracket included. bracket included *10 sec
*30 sec
0.05 – 10sec 0 – 1S 0 – 1H 999,9 sec Time Selections *60 sec
0.05 – 10min 0 – 10S 0 – 10H 9999 sec 9999HR 9999SEC *180 sec
0.05 – 10 hour 0 – 1M 0 – 60H 999,9 min 9999MIN 999,9SEC
0.05 – 10 (x10 hour) 0 – 10M 0 – 600H 9999 min 999,9MIN 99,99SEC DC: *12, *24VDC
AC: *24, *110, *230VAC
100-24VAC 24-240VAC/DC 35-240VAC/DC 12VAC/DC, 24VAC/DC,
24-240VDC 110VAC, 230VAC

Code SUPPLY VOLTAGE Accessories 11 PIN Base Base for Timer AMY-2 AUTOMATION PRODUCTS
8 PIN Base P3G-11 ZM2VP
Panel Mounting Bracket
Y-50 P3G-08

Features Size: 48 x 48mm With reversed terminals With reversed terminals RE1
for AH5N, AH5F & SP3-48
DPM 14 Pin DIN Rail Mount Base
For more plug-in bases see pages 39-42
34

DIGITAL TIMERS & COUNTERS

Type Timer Timer/ Counter Pre-Set Counter Up / Down Total Counter
Totalizing Counter Hour Meter

6 Timing Functions Auto or Manual Reset Auto or Manual Reset Manual or Electronic Reset

Code DHC48 DHC10J DHC5J DHC9J-J DHC15J

Size(mm) 48 x 48 x 92 48 x 48 48 x 48 x 92 36 x 72 x 77 2 Module DIN mount
Panel Cutout 45 x 45 45 x 45 45 x 45 33 x 68.5 0-99999999
Range Timer: 0.01s-99h59m
Delay ON/ Interval/ Equal Counter: 0-9999 0-9999 0-9999
Repeating. 0.01s-99h59m

Counting Speed – 30/500cps 30/1000cps 30/1000cps 10cps
Display 0.3 inch LED (4 digit) 8 digit LCD display
Power Supply 2 line 4 digit LED 0.3 inch LED (4 digit) 0.56 inch LED (6 digit) 100-240VAC/DC
Input Signal 100-240VAC/DC
Pulse Start & Reset 100-240VAC/DC 100-240VAC/DC (12-24VAC/DC) 100-240VAC/DC DC 4-30V
Output
Memory Backup 2 C/O 3A@250VAC Contact or solid-state [H]: Contact or solid-state [H]: 4~30V Contact or solid-state [H]: -
– 4~30V [L]: 0~2V Input ≥ 4.7kΩ [L]: 0~2V Input ≥ 4.7kΩ 4~30V [L]: 0~2V Input ≥ 4.7kΩ 5 years

1 C/O 3A@250VAC 1 C/O 3A@250VAC -

10 years 10 years 10 years

DIGITAL TIMER WITH DISPLAY HOUR METERS

Range Code LCD Hour Meter

9999 (S) (H) (M), NT-411 Panel cut out 50 x 25mm
99M 59S, 99H 59S • 8 digit LCD Hour Meter
99 Days 23H Contacts: • Panel Mount
5A @ 250VAC • External reset
Supply: Operation:
AC: 110 and 230VAC 4 digit setting & d­ isplay Range Input Code
timer with multi output 999999H59M 80-250VAC LT8MA1
Diagram: mode: delay auto reset. 999999H59M Contact LT8MC1
Auto/man reset and self 999999H59M 6-30VDC LT8MD1
hold, Instant reset.
Remote start/stop & Power Supply Connections
reset.
Mounting: • 2 x AA batteries included
72 x 72mm • Estimated Battery life is 3 years
• Low battery ­indication

For more hour meters see page 163

Mechanical ELECTROMECHANICAL TIMERS TOTALIZER
Timers
With LCD Totalizer – Battery Operated
Motor
Size 56 x 31mm
Panel cutout
50 x 25mm

AUTOMATION PRODUCTS G-100 MI-4 JV100 Speed No Reset With Reset
10Hz LC8MC1 LC8MC1R
Time Range Code Time Range Code Time Range Code 50Hz LC8MC3 LC8MC3R

2-30s G-100 30S 1-15m MI-4 15M 0.3-12h JV100 12H*
3-60s G-100 60S 1.6-30m MI-4 30M
15-300s G-100 300S 3-60m MI-4 60M 0.6-24h JV100 24H* • 8 digit LCD
10-4m (240 sec) G-100 4M 6-120m MI-4 120M totalizer (up
20-7m (420 sec) G-100 7M 15m-6h MI-4 6H *Add AC voltage to code: 110V, count) with
45-15m G-100 15M 30m-12h MI-4 12H 230V, 400V. More accurate for long external reset
1.5-30m G-100 30M 1-24h MI-4 24H time ranges. Time tolerance ±2%. • Battery life 3
3-60m G-100 60M Contact 16A @ 250VAC (NO + NC) years type ‘AA’
1.5V 2pcs (incl).
• Time tolerance ±3% • Time tolerance ±3% • Low battery
• Contact 16A @ 250VAC (NO+NC) Contact 16A @ 250VAC (NO + NC) indication
• Contact Input

35 DPM

COUNTERS & TOTALIZERS

Type 4 Digit Up or Down Counter 4 Digit Up or Down Counter 3 Digit Up Counter 4 Digit Counter 6 Digit Up or
0-999 6 Digit Totalizer Down Counter
0-9999 0-9999 with power off memory

Code AH5K SC-48 ASC-3 NC-4116 NC-611
Relay Outputs
Size 5A @ 250VAC 5A @ 250VAC 5A @ 250VAC 3A @ 250VAC
Specification
48 x 48mm Panel Mount & 8 PIN 48 x 48mm Panel Mount & 8 PIN 65 x 50mm Panel cut-out 72 x 72mm Panel Mount
Supply Volts only
Connection plug-in c/w mounting bracket plug-in c/w mounting bracket & 8 PIN plug-in
Diagram 6 digit pulse counter with delay
Up/Down count to 9999 Up/Down count to 9999. Up Count to 999 auto reset, instant reset, auto/
Contact Input. man. reset and self hold.
Auto Reset or Reset by r­emoving Sampling Multiplying Factor. Reset by removing power Remote start/stop reset.
20CPS Total reset on front of unit.
power. Auto Reset/Manual Reset. Selectable 250CPS or 25CPS.
Addition/Subtraction Count.
12VDC 30mA supply for proximity Output Relay Delay: 0.1 to 9.9 Output: Relay and NPN O/P

switches. sec. AC: 110 and 230VAC

Input: Contact or NPN proxi­mity 12VDC 30mA supply for proximity

sensor (see pages 295-296). sensor (see pages 295-296).

IS-18-C3-03 or equivalent. 250CPS 500CPS

24-240VAC/DC AC: 110 or 230VAC AC: 110 and 230VAC

Other Counters - Mechanical Pulse Counters 6 Digits (Panel Mount)

Without Reset With Reset

AC DC AC DC AUTOMATION PRODUCTS
NX-06P 24VAC FX-06P 12VDC E-16Y 24VAC E-16Y 12VDC
NX-06P 110VAC FX-06P 24VDC E-16Y 110VAC E-16Y 24VDC
NX-06P 230VAC E-16Y 230VAC
Count Speed 10CPS Count Speed 20CPS Count Speed 10CPS
Panel cutout 25 x 40mm Panel cutout 19 x 30mm Count Speed 10CPS Panel cutout 25 x 45mm
Panel cutout 25 x 45mm
Counting Speed
Base Mount - Without Reset 10 CPS
10 CPS
Code Supply Voltage Consumption
LFC-6N 12VDC
LFC-6N 24VDC 12VDC 3.5W
24VDC 3.5W

On-time continuously rated at rated voltage

DPM 36

MECHANICAL COUNTERS

Meter Counters Turn Counters

Water-Tight

Code EM-12M EM-24M EM-6R EM-5R EM-5RE

Digits 5 5 6 5 5
Digit Size 7mm 4.5mm 8mm 4.5mm 4.5mm
Max Speed 500mpm 500mpm 600rpm 500rpm
Reset Pushbutton Pushbutton Key Pushbutton –
Size 150 x 80 x 50.5mm 112 x 45 x 35mm 150 x 80 x 50.5mm 112 x 45 x 35mm Knob
62 x 45.5 x 30mm
Features • Position of the impulse shaft on both sides. • Position of the impulse • Position of the impulse
• Addition/subtraction variable according to requirements shaft on both sides. shaft on both sides. • Special for use in
• Addition / Subtraction • Addition / Subtraction adverse environments:
• Turning relation: • Turning relation: variable according to variable according to Chemical industries,
2 turns =1m 5 turns = 1m requirements. requirements. outdoors, etc.
• Spare reset key.
Code: EM-ZSK

Please Note: our range of meter and Revolution Counters Weatherproof Stroke Counter
turn counters count as illustrated

Pre-Select Counters

• Position of the impulse shaft on both sides. • Position of lever on the shaft, variable
• Addition / Subtraction variable according to requirements according to requirements.
• Cuts the electrical signal when reaches "0" reducing • Rear mounting by ØM4 screws
from a number previously selected.
• 1 C/O 1A@230VAC EM-22GE
5
Code EM-12EPR JJ-75-I JJ-67-1
Digits 5 5 5 4.5mm
Digit Size 8 4.4 1000spm
Max Speed 7mm
Reset – 350rpm 350rpm Wheel
Size (mm) Lever Wheel 62 x 45.5 x 30
Pushbutton 147 x 72 x 57 80 x 37 x 30
150 x 80 x 55
Stroke Counters

AUTOMATION PRODUCTS Code JJ-75-II JJ-108A JJ-1142 JJ-114 JJ-101
Digits 5 5 6 5 5
4
Digit Size (mm) 8 4.4 4.4 4.4
500c/s
Max Speed 500c/s 500c/s 500c/s 500c/s Wheel
65 x 37 x 32
Reset Lever Non-Reset Wheel Wheel

Size (mm) 119 x 72 x 57 50 x 42 x 35 86 x 47 x 34 80 x 46 x 32

Position of lever on shaft, variable according to requirements. Automatic return to initial position after each impulse.

37 DPM

METER COUNTER ASSEMBLIES

c/w Bench Clamp

Code EM-8MP EM-12MP EM-12MTP EM-24MP
Digit Size
Max Speed 7mm 7mm 7mm 7mm
Reset 500mpm 300mpm 300mpm 200mpm
Weight Pushbutton Pushbutton Pushbutton Pushbutton
Diameters 1.4kg 2.1kg 2.7kg 0.5kg
Max Length – 3 to 23mm 3 to 20mm 3 to 23mm
Wheel Size 9999.99m 9999.99m 9999.99m 9999.99m
Spare Counter 500mm 500mm 500mm 200mm
Features EM-12M EM-12M EM-12M EM-24M

• Meter counter 12m • For measuring cables, • For measuring cables, • For measuring cables, pipes,
• 2 wheels 500mm pipes, ropes, etc. pipes, ropes, etc. ropes, etc.
• Counter balance
• Fabric measuring, steel rolls etc. • c/w bench clamp. • Manual table assembly. • Manual hand grip.

Accessories

Code EM-G5 EM-G2 EM-A5 EM-A2 EM-E5 EM-E2 RG500 RG200
Aluminium Aluminium Aluminium Aluminium Plastic Plastic Rubber Rubber
Material
Diameter/ 159.154/25mm 63.66/12.5mm 159.154/28mm 63.66/13mm 159.154/24.5mm 63.66/17.6mm 200mm
Thickness
Perimeter 500mm (2:1) 200mm (5:1) 500mm (2:1) 200mm (5:1) 500mm (2:1) 200mm (5:1) 500mm EM-G5
Axle Ø7mm Ø6mm Ø7mm Ø6mm Ø7mm Ø6mm EM-E5
Accessory for: 8MP 24MP 8MP 24MP 8MP 24MP EM-G5
12MP 12MP 12MP EM-E5
12MTP 12MTP 12MTP

Tally Counters Road Counter

Hand Tally Desk Tally

Code H102 D102C WM-12M WM-08 AUTOMATION PRODUCTS

• 4 Digit Counter • 4 Digit Counter • 318mm (12”) wheel • 212mm (8”) wheel
• Ideally used for traffic • Ideally used for traffic • Accuracy 99.96% • Accuracy 99.96%
• Carry bag included • Carry bag included
surveys, assembly line surveys, assembly line • T elescopic handle • Telescopic handle
parts counting, attendance parts counting, attendance • Kick Down Stand • Reset
at any functions etc. at any functions etc. • Handle Reset

DPM 38

RELAYS & BASES

D2/N D - Series Relays - c/w Flag Indication and Mechanical Latch

1 C/O 2 C/O 4 C/O AC DC
16A 10A 5A

D4/N Base Mounting

– D2/N D4/N 6VAC 6VDC
D1/N D2/N D4/N 12VAC 12VDC
– D2/N D4/N 24VAC 24VDC
– D2/N D4/N 48VAC 48VDC
– D2/N D4/N 60VAC 60VDC
– D2/N D4/N 110VAC 110VDC
– D2/N D4/N 230VAC 220VDC

PCB Mounting 12VDC
24VDC
– D2/P D4/P – –
D1/P D2/P D4/P 24VAC –
– D2/P D4/P 110VAC
– D2/P D4/P 230VAC Code
ZM2CS
Bases & Accessories for D-Series Relays ZM3CS
ZM4CS
ZMD2/4 Compact screw terminal base IP20 250V & Printed Circuit Base 250V ZM6CS
ML LED Modules Description ZM8CS
For D1 & D2 Relays
Description Width Code For D3 Relays Code
For D4 Relays ZM2SP
For D1 & D2 Relays 26mm ZMD2 For D6 Relays ZM3SP
For D8 Relays ZM4SP
For D4 Relays 26mm ZMD4
Code
MPD Ejector/Retaining Clip - MPD MBD
MBM
Ejector/Retaining Clip LED Module - ML*
Voltages
*Add Voltage: 24, 110, 230VAC/DC

Compact screw terminal base IP20 300V Solar Panel Base 250V
& LED Modules Description
For D1 & D2 Relays
For D1 & D2 relays 30mm ZM2VP For D3 Relays
For D4 Relays
ZM2/4VP For D3 relays 30mm ZM3VP†
Retaining Clips
AL For D4 relays 30mm ZM4VP Description
D1 to D4 Relays
LED Module †Does not accept LED moudule For ZM4M base

LED Module for: AL*
ZM2VP / ZM4VP / ZM4M

*Add Voltage 024, 060, 230 (110-230VAC/DC)

Diode Module A-D

Compact screw terminal base IP20 250V
Suitable for Diode or LED Modules

ZM4M For D4 Relays ZM4M

E-Series PCB Relays

Standard Relays Latching Bi-Stable Relays

AUTOMATION PRODUCTS 2 C/O 1 C/O 1 C/O 1Coil 1 Coil 2 Coil AC DC
5A 10A 16A 1C/O 10A 2 C/O 5A 2 C/O 5A

E52/S E51/S – – – – – 4VDC
E52/S E51/S E61/S
RT424 Latching Relays E52/S E51/S E61/S –– – 6VAC 6VDC
*DC Coil Voltages Only E52/S E51/S E61/S
E-Series E52/S E51/S E61/S – – – – 9VDC
E52/S E51/S E61/S
E52/S E51/S E61/S – RT424A12 RT424F12 12VAC 12VDC
E52/S E51/S E61/S
E52/S E51/S E61/S – RT424A24 RT424F24 24VAC 24VDC
E52/S E51/S E61/S
– – – – – – 36VAC 36VDC

– – – 48VAC 48VDC

– – – 60VAC 60VDC

VIEW ON TERMINALS VIEW ON TERMINALS VIEW ON TERMINALS – – – 110VAC 110VDC

E51/R1 E52/R2 5A E52/S, – – – 230VAC –
E51/S RT424F E61/S &
RT424A E51/R1 E52/R1 –
220VAC/DC –

39 RE1

RELAYS & BASES

C - Series Relays - 10A 250V - c/w Flag and LED Indication

8 Pin 11 Pin AC DC
2 C/O 3 C/O
10A 8 pin - 6VAC 6VDC
10A 11 pin C42 C43 - 12VDC
C42 C43 24VAC 24VDC
C43 C43 11 Pin C42 - 32VAC -
C42 8 Pin C42 C43 36VAC 36VDC
C42 C43 48VAC 48VDC
C42 C43 60VAC (C42) 60VDC
C42 C43 110VAC 110VDC
C42 C43 230VAC 220VDC (C42)
C42

Bases for C42 & C43 Relays

Screw terminal base (IP20) 300V Screw terminal base (IP20) 300V

Description Width Code Description Width Code

8 PIN 40mm ZOVI 8 PIN 38mm ZVO
11 PIN 38mm ZVU
ZOVI 11 PIN 43mm ZUVI

Suitable for LED module

Solder Panel Base - 300V

ZUVI Description Width Code
8 PIN - AZOS
11 PIN - AZUS

Screw terminal oval base (IP20) 300V Solder Cable Cover Base

Description Width Code Description Width Code

8 PIN (black) 38mm BOV 8 PIN - ZOQS
11 PIN (black) 38mm BUV ZUQS
11 PIN -

Screw terminal base (IP20) 400V Printed Circuit Base - 300V

Description Width Code Description Width Code
8 PIN -
8 PIN 38mm ZVE8 11 PIN - AZOCS
AZUCS
11 PIN 38mm ZVE11

Screw terminal base (IP00) 300V Accessories Description Code

Description Width Code Retaining clip MBOU
8 PIN 36mm for C42 & C43 relays
11 PIN 36mm ZROV
ZRUV Diode Module for ZVO & ZVU A-D

LED Module for ZVO & ZVU AL*

*Add voltage 024, 060, 230 (110-230VAC/DC)

G-Series - Low-profile hermetically sealed PCB Relays

Volts 3.5mm Pin spacing 5mm Pin spacing
DC 12A (1C/O)
12A (1C/O) 16A (1C/O) 8A (2C/O)
GN8-2C 12VDC
F15 A-5,0mm 12V GN13-1C 12VDC GN12-1C 12VDC GN16-1C 12VDC GN8-2C 24VDC
F13 A-3.2mm
24V GN13-1C 24VDC GN12-1C 24VDC GN16-1C 24VDC
VIEW ON TERMINALS

GN12/13

Bases for E-Series Relays 10A 250V & Retaining Clips Bases for E & G-Series Relays 10A 250V AUTOMATION PRODUCTS

Screw terminal IP20 Retaining Clip

Description Code Code MPE

For E & F15 relays ZME5 With eject function

For F13 relay ZME3 Printed Circuit Base IP20 Retaining Clip

LED Module * Add voltage to code: 024, 060, 110, 230VAC/DC Description Code Code

Fits ZME3 and ML* For GN13 relays ZMECS/3.5 MBE
ZME5 bases only 3.5mm pin spacing

Screw terminal IP20 Retaining Clip

Description Code Code MEM
For E relays ZMEM/5
Screw terminal IP20 Retaining Clip Description Code Code
Description Code Code MEM MBE
For E relays ZMEM/5 For E & F15 relays ZMECS/5
5.0mm pin spacing

RE1 40

INDUSTRIAL RELAYS

Type 8 Pin Plug-in Relay Flat 14 Pin Plug-in Relay Flat 8 Pin Plug-in Relay Flat 14 Pin Plug-in Relay Flat

RELAYS 2 Pole Change Over (5A) 4 Pole Change Over (5A) 2 Pole Change Over (10A) 4 Pole Change Over (10A)
- Test button function *Add voltage to code *Add voltage to code *Add voltage to code *Add voltage to code
- Flag plus LED R5502-*L R5504-*L R5602-*L R5604-*L
- Orange for AC R5502-*L R5504-*L R5602-*L R5604-*L
- Blue for DC R5502-0*L R5504-0*L R5602-0*L R5604-0*L
R5502-0*L R5504-0*L R5602-0*L R5604-0*L
Relay Type R5502-0*L R5504-0*L R5602-0*L R5604-0*L
*AC *DC
230VAC —
110VAC 110VDC
48VAC 48VDC
24VAC 24VDC
12VAC 12VDC

Wiring Diagram

Bases for R5502 & R5504 Relays 300V/10A Bases for R5602 & R5604 Relays 300V/10A
Screw Terminal Base IP20 Screw Terminal Base IP20

RHE

RB944-14F ZM3VP ZM6V ZM8V

Code Description Code Description
RB943-08F ZM6V Base for R5602
RB944-14F 8 Pin blue base for 2 pole relays ZM8V Base for R5604
ZM3VP
14 Pin blue base for 2 & 4 pole relays
11 Pin black base for 2 & 3 pole relays

AB - Series Relays 10A Bases for AB2 & AB3 Relays 250V/10A
Screw Terminal Base IP20
Screw Terminal Base IP20

2 C/O 3 C/O Volts
10A 10A
AC DC ZAV/A ZACS
AB2 AB3 12 VAC 12 VDC
RE1 AB2 AB3 24 VAC 24 VDC Code Description
AB2 – 48 VAC 48 VDC ZAV/A Base for AB2 relay
AB2 AB3 110 VAC 110 VDC ZACS P.C.B. base for AB2 relay
AB2 AB3 230 VAC – Bases for Interface Relays IP20

AUTOMATION PRODUCTS Interface Relays

*Add coil voltage
to code: 230VAC,
110VAC, 24VDC,
12VDC

C12 Type C10 Type CSS-AZ S-12 Relay Bases in combination S-10M

Code Description Code Description
1 c/o 10A relay, plug-in type
C10/A10/* 2 c/o 5A relay, plug-in type S-12 Base for C12 relay 250V/5A
C12/A21/* Solid-state relay, Input 5-32VAC Out switch 3A@250VAC
CSS-AZ S-10M Base for C10/C14 relay 250V/16A

41 RHE

INDUSTRIAL RELAYS

Type 8 Pin Plug-in Relay 11 Pin Plug-in Relay 8 Pin Plug-in Relay 11 Pin Plug-in Relay

UL recognised, CE
approval

Colour coding:
Orange: AC
Blue: DC

Relay type 2 Pole Change Over (10A) 3 Pole Change Over (10A) 2 Pole Change Over (10A) 3 Pole Change Over (10A)
*Add voltage to code *Add voltage to code *Add voltage to code *Add voltage to code
*AC *DC R6002-*L R6003-*L — —
240VAC — R6002-*L R6003-*L C2/A20/* C3/A30/*
R6002-*L R6003-*L C2/A20/* C3/A30/*
230VAC 220VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
R6002-0*L R6003-0*L C2/A20/* C3/A30/*
110VAC 110VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
R6002-0*L R6003-0*L C2/A20/* C3/A30/*
48VAC 48VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
R6002-00*L R6003-00*L C2/A20/* C3/A30/*
36VAC 36VDC
Test button function Test button function Test button function & Test button function &
32VAC 32VDC Flag plus LED Flag plus LED Flag ind Flag ind

24VAC 24VDC

12VAC 12VDC

6VAC 6VDC

Features

Wiring Diagram

Bases for R6002 & R6003 Relays 300V/10A Timers IP40
Screw Terminals IP20

Code Description

BUV-B BOV-B 8 Pin oval base blue
RB750-08R
BUV-B 11 Pin oval base blue

RB750-08R 8 Pin rectangle base blue

RB740-11R 11 Pin rectangle base blue

Screw Terminals IP20 300V/10A

Code Description Code Description

RB083-08R 8 Pin rectangle base blue CT2A * 8 Pin Delay OFF timer
CT3A * 11 Pin Delay OFF timer
RB113-11R RB083-08R RB113-11R 11 Pin rectangle base blue CT2B * 8 Pin Equal Repeating timer
CT3B * 11 Pin Equal Repeating timer
Screw Terminals IP20 300V/10A CT2E * 8 Pin Delay ON timer
CT3E * 11 Pin Delay ON timer
Code Description CT2K * 8 Pin one-shot pulse start timer
CT3K * 11 Pin one-shot pulse start timer
PM-S8D 8 Pin rectangle DIN mount base CT2W * 8 Pin one-shot timer
CT3W * 11 Pin one-shot timer
PM-S11D 11 Pin rectangle DIN mount base

PM-S8D PM-S11D Retainer clip secures relay to the socket protecting AUTOMATION PRODUCTS
against vibration

Bases for C2/A20 & C3/A30 IP20 250V/10A

Code Description

S2-B 8 Pin rectangle base *Add voltage to code:
S3-B 11 Pin rectangle base S (9.5-18VDC),
L (20-65VAC/DC),
Unique retainer clip securing module to socket M (90-150VAC/DC for timer A & K),
providing protection against vibration. U (180-265VAC/DC for timer A & K),
H (90-265VAC/DC for timer B, E & W)
A - Series Relays - For use with fast-on connectors

Type 1 N/O 2 N/O 1 C/O Coil Volts
30A 16A 16A AC DC

30A 1C/O, A1/1 A1/2 A1/A 12 VAC 12 VDC The module CT2 & CT3 are electronic timers which are
16A 2C/O A1/1 A1/2 A1/A 24 VAC 24 VDC designed to be inserted between a standard plug-in relay and its
A1/1 A1/2 A1/A 110 VAC socket, enabling the relay to be operated as a timer relay. The
A1/2 RE1 A1/1 A1/2 A1/A 230 VAC relay coil voltage must be in the range shown for each model.

RHE 42

RELAYS

JQX - Series PCB Relays

Voltage 1C/O 10A 2C/O 5A 1C/O 16A

12VDC JQX-14FC-1C 12VD JQX-14FC-2C 12VD JQX-14FC-1CH 12VD

24VDC JQX-14FC-1C 24VD JQX-14FC-2C 24VD JQX-14FC-1CH 24VD

VIEW ON TERMINALS VIEW ON TERMINALS

Base 10A 250V for JQX Relay IP20 JQX-50F Series - 1 C/O 30A - No Base, Screw Terminals

Code Description Code Volts
PSF14AE/L JQX-50F 12VDC
For E-Relays JQX-50F 24VDC
5mm PIN spacing JQX-50F 110VAC
JQX-50F 230VAC

T73-Series - 10A 1C/O Relays Code Volts
Description

1 C/O 10A @ 250VAC T73 12VDC 12VDC
T73 24VDC 24VDC

AUTOMATION PRODUCTSF1/C BOTTOM VIEW F-Series - Automotive Relays F1/C 12VDC 12VDC
1 C/O 30A Open type F1/C 24VDC 24VDC
COM F2 12VDC 12VDC
1 C/O 30A Enclosed type F2 24VDC 24VDC
F2

TRK-Series - Automotive Relays 30A, 80A 1C/O

1 C/O 30A TRK792 12VDC 12VDC
1 C/O 80A TRK792 24VDC 24VDC
ALB-80 12VDC 12VDC
ALB-80 24VDC 24VDC

CGB-1C CGB & JQX-30F Series 40A 1C/O 20A 2C/O 12VDC
JQX-30F 24VDC
CGB-1C JQX-30F 110VAC
CGB-1C JQX-30F 230VAC
CGB-1C JQX-30F
CGB-1C JQX-30F

DIN MOUNT RELAYS

DIN Mount Relays • 16A - 250V Momentary Contacts DIN Step Relay Control Contacts
Capacity: Incandescent lamps 2400W fluorescent lamps with Relay Type Width Code voltage Type
Code (17.5mm) VAC
p.f. correction 500W halogen lamps 1000W GW96601 N/O GW96626 C/O
GW96602 N/O 1 GW96627 12V C/O
GW96638 GW96603 N/O 1 GW96628 24V C/O
GW96601/02/03 GW96613 C/O 1 GW96638 230V 2 N/O
GW96616 4 N/O 1 GW96641 230V 4 N/O
GW96617 4 N/O 2 GW96642 12V 4 N/O
GW96618 4 N/O 2 GW96643 24V 4 N/O
Contactors 2 230V
Contacts No. of
GW99613 Code Type Rated Current Coil Mod.
GW96626/27/28 @ 400V Voltage
GWD6731 2 N/O 3
GWD6708/22/31/2/4 GWD6708 3 N/O 63A 230VAC/DC 2
GWD6722 3 N/O 20A 230VAC 3
GEW GWD6732 3 N/O 40A 230VAC/DC 3
GWD6734 4 N/O 63A 230VAC/DC 3
63A 230VAC/DC

43 RE1

RELAY INTERFACE MODULES

Open Base Type Closed Base Slim Type 5A Box Type

IMZ RB-4/8/12L RB-4/8/12LP & LPP RB-1CP RB-4/8/12CP RB-1SL RB-8SL RB-4/8/16BT
RB2-1CP
DIN Mounting Fixed Relays Plug-in Relays 16-Way DIN Mounting
8-Way 12-Way 16-Way L &LP Type
Code 1-Way 4-Way
RB-16CP
SPDT (1C/O) 10A (DIN Mounting) L & LP with 20
way ribbon plug

Fixed relays open base – RB-4L* RB-8L* RB-12L* RB-16L*
RB-16LP*
Plug-in relays open base – RB-4LP* RB-8LP* RB-12LP* RB-16CP*

Plug-in relays closed base RB-1CP* RB-4CP* RB-8CP* RB-12CP* RB-16BT 24VDC

Slim type RB-1SL* – RB-8SL 24VDC –

Box type – RB-4BT 24VDC RB-8BT 24VDC –

Base without relay IMZ – ––

*Add voltage required: 24, 110, 230VAC; 12, 24, 110VDC

*NB: All Codes are for common negative, for common positive add “P” to Code, eg. RB-4LPP
Common Positive only available in LP Range

DPDT (2 C/O) 5A (DIN Mounting)

Fixed relays open base – RB2-4L* RB2-8L* RB2-12L* RB2-16L*
Plug-in relays open base – RB2-4LP* RB2-8LP* RB2-12LP* RB2-16LP*
Plug-in relays closed base RB2-1CP* RB2-4CP* RB2-8CP* RB2-12CP* RB2-16CP*

*Add voltage required: 24, 110, 230VAC; 12, 24, 110VDC

*NB: All Codes are for common negative, for common positive add “P” to Code, eg. RB2-4LPP
Common negative only available in LP Range

Inter-Connecting Modules Opto Coupling Modules

Flat Connector Sub-D Connector Male DC in/DC out 1-Way 4-Way DC in/AC out
Input Output Output
Code No. of Poles Code No. of Poles Code 1-Way Code 4-Way Volts Volts Current
24VDC 5-48VDC 100mA
JUM72-16 16-Way JUM72-D15 15-Way OCM1-24VDC OCM4-24VDC AUTOMATION PRODUCTS
JUM72-26 26-Way JUM72-D25 25-Way OCM1-220VDC OCM4-220VDC 240VDC 5-300VDC 100mA
JUM72-34 34-Way JUM72-D37 37-Way ET-MS01 ET-MSZ04
JUM72-40 40-Way JUM72-D50 50-Way 24VDC 240VAC 4A
JUM72-50 50-Way

Size: Slim Type Relays Step Relay (Base Mount) 10A @ 250VAC
20mm(L) x
5mm(W) x Code No. of Step 1 Sequences 4
12.5mm(H) AFH-BF01* 2 23

AFH-BF02* 2

Code Coil Volts Contact Rating NB: Not continuously AFH-BF04* 4
SA-1A 12VDC (20.4mA) 5A C/O rated coils (pulse only) *Add Voltage: 12VDC, 12VAC, 24VDC, 24VAC, 110VAC, 230VAC
SA-1A 24VDC (10.2mA)
5A C/O

RE1 44

SOLID STATE CONTACTORS

Code Poles Operational Current Rating Control Voltage Ultra Fast
Voltage AC1 AC3 Fuse

SSRSC1-15 1 24-240VAC 15A 3A 24-230VAC/DC 15A

SSRSC1-30 1 24-240VAC 30A 7A 24-230VAC/DC 30A

SSRSC1-50 1 24-240VAC 50A 12A 24-230VAC/DC 50A

SSRSC2-30 2 48-600VAC 30A 7A 24-230VAC/DC 30A

SSRSC2-50 2 48-600VAC 50A 12A 24-230VAC/DC 50A

SSRSC3-10 3 48-600VAC 10A 2A 24-230VAC/DC 10A

SSRSC3-20 3 48-600VAC 20A 4.5A 24-230VAC/DC 20A

Specification • LED status indication • Integrated heatsink • IP20 protection • Bounce free & Arcless switching

• Built-in varistor protection • For motor, lamps, heaters, etc • Zero crossing commutation • High switching frequency

INDUSTRIAL SOLID STATE RELAYS

1 Phase Solid State Relays

Code Line Di-Electric Contol Maximum
Voltage AC Strength Voltage Current

Single Phase HHG1C-1/32F-1206 60-1200VAC 2.5kV 3-32VDC 60A
Three Phase HHG1C-1/32F-1208 60-1200VAC 2.5kV 3-32VDC 80A
HHG1C-1/32F-1210 60-1200VAC 2.5kV 3-32VDC 100A
HHG1C-1/32F-1215 60-1200VAC 2.5kV 3-32VDC 150A
HHG1C-1/32F-1220 60-1200VAC 2.5kV 3-32VDC 200A
HHG1C-1/32F-1225 60-1200VAC 2.5kV 3-32VDC 250A

Specification • Insulation Resistance: 500MΩ 500 VDC • Voltage Drop: Less than 1.6 VAC

• Ambient Temperature: - 30 - 80˚C • Working Indicator: LED

3 Phase Solid State Relays

Code Code Line Di-Electric Maximum
Strength Current
3-32VDC Control 90-250VAC Control Voltage

HHG1-3/32F10 HHG1-3/250F10 400VAC 2500VAC 10A
HHG1-3/32F20 HHG1-3/250F20 400VAC 2500VAC 20A
HHG1-3/32F40 HHG1-3/250F40 400VAC 2500VAC 40A
HHG1-3/32F80 HHG1-3/250F80 400VAC 2500VAC 75A
HHG1-3/32F100 HHG1-3/250F100 400VAC 2500VAC 100A
HHG1-3/32F120 HHG1-3/250F120 400VAC 2500VAC 120A

Specification • Insulation Resistance: 500MΩ / 500VDC • Voltage Drop: Less than ≤1.6VAC

• Temperature: - 30 - 80˚ • Working Indicator: LED • Control Current: 5-30mA • On-Off Time ≤10mS

3 Phase Solid State Reversable Relays

Line Line Di-electric Control Max. Current Max. Current Max. Current
Voltage AC Strength Voltage** 10A 25A 40A

400V 2500VAC 4.5 - 5.5VDC HHG1F-3/5 10A HHG1F-3/5 25A HHG1F-3/5 40A

400V 2500VAC 9 - 11VDC HHG1F-3/10 10A HHG1F-3/10 25A HHG1F-3/10 40A

**Note control voltage must not be exceeded

DC SOLID STATE RELAYS

DC Switching Solid State Relays - Size (mm) 42L x 25W x 10D

AUTOMATION PRODUCTS RD Load Voltage Control Voltage Max. Current 1A Max. Current 4A

3-60VDC 3-32VDC - RD0605-D
3-200VDC 3-32VDC RD2001-D -
3-350VDC 3-32VDC RD3501-D -

DC Switching Solid State Relays - Chassis Mount

CT-SSR-5DD Load Voltage Control Voltage Max. Current 1A Max. Current 5A
3-60VDC 3-32VDC -
1. In general CT-SSR-5DD
Current, voltage,
temperature and load type Heater Connection
are crucial factors when
mounting SSRs’. This 2. Protection against overload 3. Protection against 4. Protection against
applies to single as well as
3-phase relays. The relay is to be protected voltage transients excessive heating
against overload
and short-circuit by means The relay must be protected The relay must be protected
of a semi-conductor fuse. against voltage transients effectively against excessive
by mounting a varistor heating. Do not forget to
across the semiconductor. apply conducting paste
between relay and heatsink.

45 EES

SOLID STATE RELAYS

RS-Series S.S.R.

Load Non-Rep. Control Max. Current Max.Current Max.Current
Voltage Peak Voltage Voltage 40A AC1
10A AC1 25A AC1 (8A) AC3

(2A) AC3 (5A) AC3 RS1A23D40
RS1A23LA40
230VACrms 650Vp 4.5-32VDC RS1A23D10 RS1A23D25 RS1A48D40
480VACrms 1200Vp 18-36VAC/DC RS1A23LA10 RS1A23LA25 RS1A48LA40
4.5-32VDC RS1A48D10 RS1A48D25
18-36VAC/DC RS1A48LA10 RS1A48LA25

RS • Triac or Alternistor switching mode • LED indication • Protection Cap.
• Zero switching 1 phase solid state relays for resistive, inductive and capacitive loads
RM1A
RM1C RM-Series S.S.R.
R2425 & R2441
SSR-VR Load Non-Rep. Control Max. Current Max.Current Max.Current Max.Current
Voltage Peak Voltage
Voltage 25A AC1 50A AC1 75A AC1 100A AC1

(5A) AC3 (10A) AC3 (15A) AC3 (20A) AC3

230VACrms 650Vp 4-32VDC RM1A23D25 RM1A23D50 RM1A23D75 RM1A23D100

24-265VAC RM1A23A25 RM1A23A50 RM1A23A75 RM1A23A100
24-48VDC

480VACrms 1200Vp 4-32VDC RM1A48D25 RM1A48D50 RM1A48D75 RM1A48D100
RM1A48A50 RM1A48A75 RM1A48A100
24-265VAC RM1A48A25
24-48VDC

600VACrms 1600Vp 4-32VDC RM1A60D25 RM1A60D50 RM1A60D75 RM1A60D100
RM1A60A50 RM1A60A75 RM1A60A100
24-265VAC RM1A60A25
24-48VDC

• Zero switching 1 phase solid state relay. • Thyristor switching • LED indication • Built-in varistor • Protection Cap

Peak Switching 1 Phase Solid State Relays

400VACrms 800Vp 4-32VDC RM1C40D25 RM1C40D50 - -
600VACrms 1400Vp 4-32VDC RM1C60D25 RM1C60D50 - -
For inductive loads with iron core (eg neon lighting transformers)

Analog Switching 1 Phase Solid State Relays (with proportional output)

Load Non-Rep. Control Max. Current Max. Current
Voltage Peak Volts Voltage 25A(AC51) 50A(AC51)

90-280VAC 650Vp 4-20mA DC RE2425-AA06 RE2450-AA06
RE4825-AA12 RE4850-AA12
265-530VAC 1200Vp 4-20mA DC R2425 (25A) R2441 (41A)Supplied c/w 100K POT

90-280VAC 650Vp 0-200K Ω

For resistive, inductive & capacitive loads

Built-in Potentiometer Max. Current Max. Current Max. Current Max. Current
10A 15A 25A 40A
Load Non-Rep. Control
Voltage Peak Volts Voltage SSR-VR2-10 SSR-VR2-15 SSR-VR2-25 SSR-VR2-40
24-380VAC 600V Peak Pot -fixed

For resistive, inductive & capacitive loads. Isolation Voltage: >2500VRMS

SSR ACCESSORIES & HEAT SINKS

Accessories

RHS180 RHS127 AUTOMATION PRODUCTS

RHS120 RHS150 Heat Sinks SSR RHS105
RHS300 1-Phase
Code Size (mm) 1-Phase Mounting RMIP20
LxWxD 1-Phase
1-Phase DIN Rail / Screw
RHS45A 100 x 50 x 96 3-Phase DIN Rail BRR
3-Phase Screw
RHS100 85 x 45 x 82 3-Phase Screw RHS00
3-Phase Base Mount
RHS127 127 x 70 x 50 3-Phase DIN Rail / Screw
Screw
RHS180 180 x 150 x 48 Screw c/w fan Code Description
Screw c/w fan RMIP20 Spare cover for RS1 & RM1
RHS300 150 x 88 x 35 RHS00 DIN rail adaptor for 1 phase
BRR Clear cover for 1 Phase
RHS301 115 x 100 x 96
46
RHS105 105 x 100 x 80

RHS150 150 x 125 x 135

RHS100 RHS45A RHS301 RHS120 200 x 125 x 135

EES

FLOAT SWITCHES

Micro Float Switch Micro & Mercury Mercury Float Switches Accessories
Float Switches

30mm Ø
Ideal for autoclaves

Typical Application B-01/5 B-01/10 MAG-* MER-* REMEX-P MER30/5 Not for use with
showing use of 1 B-01 float 5metres 10metres *Add 05, 10, 15, 20 metres Mercury Float
switch to start and stop ✔ ✔ ✔ N/A 1m Float Cord No cable 5 metres
pump. One B-01 Float Switches
Switch can be used for ✔ N/A MAG-W
both high and low levels. 1.5kg weight to
240VAC/200VDC 250VAC 440VAC/200VDC 250V hold MAG Float.
Code 4A 4A 0.5A 5A 5A Switches down in
Length of Cable 15A 6A 1A 10A – tanks.
Weight Supplied Micro C/O Micro NO+NC Mercury C/O Mercury N.O. Mercury N.O.
Switching Voltage Max. MER30/GP
Switching Current Max. (A) 0°C to 60°C -20°C to 50°C -20°C to 70°C -20°C to 60°C/8 bar 11/4” male gland
Carry Current Max. (A) plug for use with
Switch Type Polypropylene/Cable P.V.C. Moplen/Cable P.V.C ABS Moplen MER30/5
Operating Temperature Water & weak Acids Water & weak Acids
Material Water & weak Acids Water & weak Acids
Resistance to

Plastic Reed Float Switches - Not suitable for use in Diesel or Petrol

External (Threaded) Thread 177mm
LS-103-4 1/8”
1/2” NPT M16
LEVEL CONTROL & PUMPS FF-80EFM

53mm 177mm

Internal (Compression) ø 25mm RF-0V41 FF-81EFM
LS-103-3 RF-0V2 RF-0V41
Code Hole ø 20mm FF-80EFM FF-81EFM
RF-0V2
Mounting Internal External
Thread Size LS-103-3 LS-103-4 Flange M20
Length Lead Wire Compression
Switching Voltage Max. 1/8" PF M16 2” x 5kg/cm2 Connection Screw
Switching Current Max. (A) M16 1/2" NPT
Carry Current Max. (A) 300mm 300mm
Switch Type 300mm
Max. Pressure (kg/cm2) 240VAC/200VDC 240VAC/200VDC
Operating Temperature 240VAC/200VDC
Material 0,5A 0,5A
Suitable Specific Gravity 0,5A
Resistance to: 1A 1A
1A
47 Reed Switch N.O. Reed Switch N.O.
Reed Switch N.O.
1 4 10
4
-20°C to 80°C -10°C to 80°C
-20°C to 80°C
Polypropylene (PP) Polypropylene (PP)
Polypropylene (PP)
0,7 g/cm3 0,7 g/cm3 0,6 g/cm3

Water, Acids & Oils Water, Acids & Oils Corrosive liquids, i.e. Acids, Seawater etc

PRO

STAINLESS STEEL FLOAT SWITCHES IP65

Side Mount - RF-3002D

75mm

LF-10CEQ FD-MH16A

Top or bottom mount - RF-3001 260mm

Thread
1/8”

57mm LF-10CEM
&
Ø 28mm FD-4022 (brass)
FF-70SSS
Top/Bottom
Code RF-3001 Side Mount LF-10CEM LF-10CEQ FF-70SSS FD-MH16A FD-4022
RF-3002D
Mounting
Thread Size 1/8" PF 1/8" PF Explosion 1/2" PT
Length of Cable Adaptor 1”
Switching Voltage Max. Flange 11/2" PT Proof Flange
Switching Current Max. (A)
Carry Current Max. (A) 300mm – 300mm –
Switch Type
Max. Pressure 240VAC/200VDC 250VAC/200VDC 250VAC
Operating Temperature
Material 0,5A 2A 0.5A 5A
Suitable Specific Gravity
Resistance to: 1A 5A 1A 16A

Reed Switch N.O. or N.C. Reed switch 1C/O Reed switch N.O. Micro Switch C/O

8.5 Bar 12.8 Bar 4.2 Bar 10 Bar

-20°C to 120°C -25 to 100°C -10 to 120°C

304 Stainless Steel Housing: Aluminium IP65, Wetted parts 304 S/S 3 04 Stainless Steel Brass

0.75 S.G. 0.65 S.G. 0.8 S.G.

Water & Liquids Water, Acids & Oils Seawater, Corrosive Liq. Non-Aggresive Liq.

LEVEL PROBES & SENSORS

More Float Switches Probe Assemblies Probe Components Conductive Probe Kits IP65
1/8”
APS - 3C APS - 5C PS-5S APS-3 AF-12
1/8”

ø 25mm RHE
126mm
90mm Reed 1 PF-101 PF-104 Coated CP2/C 2-Way CP3/C 3-Way
PF-102 PF-103
40mm Reed 2 Uncoated CP2 2-Way CP3 3-Way
120mm PF-101P
c/w 2 x 1 Metre c/w 3 x 1 Metre
x Ø 4mm Rods Ø 4mm Rods

RF-0V61 RF-PV2 • Material: Nylon
1 x Reed 2 x Reed • Thread: 1.5" BSP
• Max Temp: 70˚C

RF-OV61 RF-PV2 APS-3C 3-way APS-5C 5-way Description Code LEVEL CONTROL & PUMPS

• Thread Size: 1/8” PF • 3 or 5-way holder 3 Probe holder only APS-3 DD3 EP1/C
• Steel locking ring (6 mm thread)
• O utput Reed Switch @ 1A • 3 or 5 x 1m 304 S/S probes PS-5S Accessories
250VAC • Suitable for use with all liquid 5 Probe holder only AF-12
Steel Locking ring for Code Description
• Switching • Switching level relays holders - 115mmØ
1xReed Switch 2xReed Switches CP2/CX 2-Way head only
CP3/CX 3-Way head only
N.O. Top N.O., e.g. TE101 – APS-3C, 3 Probe Spacers (porcelain) PF-101 DD2 2-Way Probe Spacer
Bot. N.C. DLR – APS-5C DD3 3-Way Probe Spacer
• Max temperature: 100°C 3 Probe Spacers (plastic) PF-101P EP1/C Spare 1m s/s Rod coated
• Max Pressure: 4kg/cm2 • Cut Probes to suit application 5 Probe Spacers (Porcelain) PF-105 EP1/U Spare uncoated s/s Rod 1m
EP1/EXT M4 Connecting Nut Brass
• Material: Polypropylene (PP) Connecting nut PF-102
(304 stainless steel)
• Specific Gravity: 0.7 S.G.
Tank probe PF-104 Coating of the rods improves resistance,
• -20 to 80℃ prevents switching caused by frothing or
1 Metre 304 stainless condensation.
steel rod 6mmØ PF-103

PRO 48

PROBE & ROTARY LEVEL SWITCHES

Optical Level Sensor IP68 Capacitive Level Vibration Probe Rotary Paddle Switch
Sensors for Solids
Switch For use in:
Milk Powder, Cement, Fertilizer,
Optical sensor Capacitive Granulated products, etc.
with infrared level sensor
light for use in for solid,
liquids such as fluid or
oil, water, ­granulated
sewerage, beer, substances.
wine etc.
(3/8” PT) 32mm Ø

Code SD10G-ARN1 (NPN NO) VP02-230TB VR1A VR1B
8mm
SD10G-ARP1 (PNP NO) Un-modulated Sensing 15mm

Sensing

Length of cable 2 meters 5 meters (PVC)

Switching Voltage 10-28VDC (NPN, N.O.) 230VAC (N.O.) 20-30VDC (1kΩ) RP10C RP80C

Operating Temperature -20°C to 80°C 0°C to 70°C SC1110 Code RP10C RP80C
Mounting 1"PF ¾"PF
Material Polysulphone Polyester • Mounting Thread 1” Thread
Size 0.5 -1kg Adjustable
Switching Current Max (A) DC: 100mA AC: 100mA 10A @ 250VAC • Probe Material S/S 304
Torque
Max ambient light 5000 lux 100 lux For use with amplifier • Housing Alu. IP65

Relay Type CLR2 • O utput: 5A @ 250V

pg 9 1C/O Gravity >0.50 S.G <0.3 S.G

DC Units for use with Relay Type CLR1 pg 9 • Supply: 0-110-230VAC Contact Micro Switch 1C/O
Type
• V ibrating Frequency:
360-370Hz Contact 5A 5A
Rating
• O perating Temp.:
-10 to 80°C Operating -10 to 60°C -40 to 85°C
Temp
• M aterial Density: 0.32g/
For 1 Level Control only cm2 Housing Aluminium IP65
Link 5 & 8 Material
Probe 5, 6, 7
R=Relay SUPPLY VOLTAGE Spare Paddle Code RP10-PADDLE RP80-PADDLE
SUPPLY VOLTAGE 230VAC

TUNING FORK LEVEL SWITCH IP65 CAPACITIVE LEVEL SWITCH IP65

Vibration Fork Level Switch

Wire Probe

200mm Application

100mm • High temperature
environment
100mm L • Corrosive
environment
LEVEL CONTROL & PUMPS Code SC1420-R SC1400-R SC2406-D • Tank application
L
• Mounting Thread 1" PT • Output: 2Wire 3mA
• Probe Material 316 • Supply Voltage: 20-250VAC, 50Hz L
• Housing Alu. IP65 • 2 Wire electronic switch
• Output: SPDT 5A 250VAC/28VDC • Fork Length: 100m SA150A
• Supply Voltage: 20-250VAC, • Operating Temperature: -40~60˚C L = 1m

50/60Hz VAC/DC SA111A-DQ-250 SA110A-DQ-150
• Vibrating Frequency 350~370Hz
• Operating Temp in Bin: -40~130C L = 250mm L = 150mm
• Material Density: >0.07 g/cm3
• Fail Safe Protection • Mounting Thread 1"PT • Sensitivity Range 10pf, STD

• Probe Material Stainless Steel 304 • Operating Temp in Bin:

• Housing Alu. IP65 -20˚C - 60˚C

• Output: 5A @ 250V, Relay • Operating Pressure:

• Supply Voltage 110/230VAC 50/60Hz 20kg/cm3

49 PRO


Click to View FlipBook Version