SOLAR LIGHTING KITS
Outdoor lighting has long been associated with solar technology. AC/DC provides another new range of Solar lighting.
These products include Solar Panels and batteries.
Security Flood Light Solar Night Light Solar Detector Light Solar Spot Light
IP44
IP56 IP65 IP44 IP44
- High Quality PV
- Rechargeable
Battery
- Super Bright
LED
PIR 10m
Detection
& Timer
Code BSSJ10 BSSJ25 BSSJ23 BSSJ03 BSSJ09
Battery Type Lead Acid Lithium Lithium Lithium Lead Acid
Battery Life 8hrs full charge 10hrs full charge 24hrs full charge 24hrs full charge 8hrs full charge
Lamp Power / Lumen 10W / 550lm 6.5W / 550lm 1W / 112lm 3.5W / 360lm 2 x 2.3W / 500lm
PV Panel 18W Polycrystalline 10W Polycrystalline 0.4W Polycrystalline 1.8W Polycrystalline 10W Polycrystalline
Accessories Mounting Kit Mounting Kit Infra-Red Motion Detector Infra-Red Motion Detector Mounting Kit
Solar Security Light Solar Motion Light Solar Guard Light Solar Gutter/Wall Light
PIR 3 - 5m IP65 PIR 2m IP65 Pole Excluded IP65 Fix to Gutter or Wall
Detection & Timer Detection & Timer
- High Quality PV Top View
- Rechargeable
Battery
- Super Bright
LED
Code ESL-09 ESL-08 BSS7CLPL SLL-02-*
Battery Type Li-ion Li-ion Lead Acid 1.2V 800mAH
Battery Life 6hrs full charge
Lamp Power / Lumen 4hrs 40hrs (Dim) / 4hrs (Bright) 13hrs full charge 0.2W / 30lm
PV Panel 4.3W / 460lm
Specifications 7W / 700lm 3W / 300lm 2V /100mA
10W Polycrystalline * Add 3 to code for
3W Polycrystalline 3W Polycrystalline Day Night Sensor
PIR Sensor. Off in daytime. PIR Sensor. Off in daytime. packet of 3
Bright light when required Bright light when required Bulk System
Solar Flood Light
at night at night Solar Courtyard Light
IP44
Solar Security Light High Power Solar Light IP44
PIR 10m IP54 PIR 10m IP65
detection detection
& timer & timer
- High Quality PV SOLAR
- Rechargeable
Battery
- Super Bright
LED
Code BX-GY-02 BSSDM02 BSSJ22 BSSJ12
Battery Type Lithium Lead Acid Lead Acid Lead Acid
Battery Life 24hrs full charge 6hrs full charge 8hrs full charge
Lamp Power / Lumen 24hrs full charge 18W / 1485lm 3.5W / 378lm 1.8W / 180lm
PV Panel 3W / 310lm 12W Polycrystalline 10W Polycrystalline 2.3W Polycrystalline
Specifications PIR, Day Night Sensor Mounting Kit PV Panel Holder
1.8W Polycrystalline
Mounting Kit included SSOOLL2
100
c/w Motion Sensor LED SOLAR LIGHTS
Sound Activated
Code RW-X12A RW-X12B LS48M-2 LS48M-5 FL-5-1
Rated Power 16 pcs 3528 LED 16 pcs 3528 LED 2W / 120lm 5W / 240lm 5W / 240lm
Battery 3.7V / 800mAh 3.7V / 800mAh 3.7V / 2000mA 7.4V / 2000mA 3.7V / 2000mA
PV Panels 1.0W Amorphous 1.0W Amorphous 2W Amorphous 5W Monocrystalline 1W Polycrystalline
Working Time 50 sec (PIR sensor) 8hrs (fully charged) 30 sec (PIR Sensor) 30 sec (PIR Sensor)
Detection Distance 36 hrs
Dimensions (mm) 2m - 5 - 7m 5 - 7m N/A
80H x 95W x 125D 80H x 95W x 125D 55H x 221W x 320D 55H x 221W x 320D
127H x 205W x 60D
COMPACT SOLAR STREET LIGHTING IP65
• Ideal for Eco Estates • Low cost installation - No cabling required
• PIR Sensor c/w Lithium Battery in body
• All in one Battery & Solar Panel • Luminosity is increased when a person is
• Colour Temperature: 6000-7000K detected by PIR Sensor
• Note: Pole Not Included
• Light is dim when no movement is detected
20 - 40W 5 - 10W Top View SOL
Split Module Self-Contained
Code LS48-5 LS48-8 LS48-10 LS48-15 LS48-20 LS48-30 LS48-40
8W 10W 15W 20W 30W 40W
Lamp Power 5W 18W 23W 25W 70W 100W 135W
960lm 810lm 1800lm 1600lm 2400lm 3200lm
Solar Panel 12W 300lm 270lm 600lm 800lm 1200lm 1600lm
Lumen Bright Mode 410lm 8hrs Bright 10hrs Bright 8hrs Bright 10hrs Bright 10hrs Bright 10hrs Bright
24hrs Dim 30hrs Dim 24hrs Dim 30hrs Dim 30hrs Dim 30hrs Dim
Lumen Dim Mode 120lm 8 - 10m 8 - 10m
4 - 5m 3 - 5m 5 - 6m 5 - 8m
Working TIme 8hrs Bright 10 - 14m 13 - 18m 13 - 18m 20m 25m 25m
9.4 LUX @ 4m 7.9 LUX @ 5m 19.5 LUX @ 5m 9.2 LUX @ 8m 8.9 LUX @ 9m 8.9 LUX @ 10m
24hrs Dim 688 x 306 x 56 818 x 306 x 56 698 x 291 x 142 892 x 817 x 228 892 x 817 x 228 1252 x 817 x 228
Installation Height 2.5 - 3m
Distance btwn Poles 8 - 10m
LUX 20 LUX @ 4m
Size - LxWxD (mm) 423 x 291 x 142
SOLAR GARDEN LIGHTING
Solar garden lights are self contained units for parks and housing developments.
These lights are easy to install and low to no maintenance is required.
SOLAR • Maintenance free
• c/w Battery Box
• Batteries to be ordered separately
LM-TT011 LM-TT012 No of Lights 1 LED Light 2 LED Lights
Code LM-TT011 LM-TT012
101 Lamp Power 12W x 2
Solar Panel 15W 70W / 18V
Controller 40W / 18V 12V / 5A
Battery 12V / 5A
Pole Height 45AH / 12V (SY12045) 80Ah / 12V (SY12080)
Battery Life 3m (Included) 3m (Included)
8hrs
8hrs
SOL2
Note: Supplied SOLAR STREET LAMPS IP65
without
batteries. 6m 6m
Batteries to be
ordered
seperately.
6m
Eco-Frie ndly
Code SOLARSL-30WSL-60W SL-90W
24V/60W LED Lamp
Light Source 12V/30W LED Lamp 24V/90W LED Lamp
Luminous Flux 2700lm 5400lm 8100lm
Colour Temp 6500K (Daylight)
Housing material 6500K (Daylight) Tempered glass and Die-cast Aluminium 6500K (Daylight)
Solar Panels Tempered glass and Die-cast Aluminium 80W*2pcs Mono Crystalline Tempered glass and Die-cast Aluminium
Battery 12V/65AH x 2pcs (SY12065)
Controller 40W*2pcs Mono Crystalline 12V/10A - PWM charging mode 120W*2pcs Mono Crystalline
12V/65AH (SY12065) Protection against over charge/discharge, 12V/100AH x 2pcs (SY120102)
Battery Box Overload & short circuit 24V/10A - PWM charging mode
Pole Included 12V/10A - PWM charging mode Integrated day/night switching Protection against over charge/discharge, Overload &
Working time Protection against over charge/discharge,
Max endurance PP Plastic short circuit
Overload & short circuit 6M, steel, hot dip galvanised Integrated day/night switching
Integrated day/night switching
8hrs per day PP Plastic
PP Plastic 3 consecutive rainy days 6M, steel, hot dip galvanised
6M, steel, hot dip galvanised
8hrs per day
8hrs per day 3 consecutive rainy days
3 consecutive rainy days
Components included
STREET LIGHTING ACCESSORIES
Charge Controllers
SOL-10/24 Code Description • Battery reverse connection protection
SOL-10/24 10A/ 24V controller • Overload and short-circuit protection
SOL-20/24 20A/ 24V controller • Battery open-circuit protection
SOL-45/24 45A/ 24V controller • Deep discharge and over-charge protection
• Solar panel reverse polarity connection protection
This controller has an advanced light-control function with • Back-flow from battery to solar module protection
an incorporated daylight switch. The lights can also be • LCD display
controlled with built-in timer function. This controller is
especially suitable for solar powered street lighting systems. LIT
Low Voltage Street Light Head
LU56W-24VDC LU56W-24VDC LED light 24VDC, cool white(5500K) 28LUX (8m) IP65.
BAT-BOX1 Pipe size 60mmØ
Pole Mounting Battery Box
BAT-BOX1 Battery Box for 2 x 80AH/12V batteries + solar controller
Size: 560 x 410 x 250mm
SOL 102
SOLAR GARDEN / STREET LIGHTING
Note: Supplied
without
batteries.
Batteries to be
ordered
seperately.
SOLAR Eco-Frie White only
ndly
c/w Built-in
day/night
switching
function
SOL
Code SGL-A-3501 SGL-A-3502 SGL-A-3505 SGL-B-4001 SDGG307
2.2m
Height 4m 4m 4m 4m
Light Source 2pcs 12V/9W LED Lamp 12V/1.2W LED Lamp
Luminous Flux 12V/9W LED Lamp 12V/9W LED Lamp 12V/9W LED Lamp 80lm
Solar Panel 700±70lm
Battery 550±50lm 550±50lm 550±50lm 40W Monocrystalline 3.5W Monocrystalline
Post Type 12V45Ah Battery (SY12045) 3.2V/6Ah Lithium
(Included) 35W Monocrystalline 35W Monocrystalline 35W Monocrystalline Galvanised steel with plastic
Working Time Glass Fibre reinforced
Endurance 12V/45Ah Battery (SY12045) 12V45Ah Battery (SY12045) 12V45Ah Battery (SY12045) spray treatment plastic pole
10hrs per day 8hrs per day
Galvanised steel with plastic Galvanised steel with plastic Galvanised steel with plastic 4 consecutive rainy days
5 consecutive rainy days
spray treatment spray treatment spray treatment
10hrs per day 10hrs per day 10hrs per day
4 consecutive rainy days 4 consecutive rainy days 4 consecutive rainy days
ALL-IN-ONE SOLAR POST-TOP LIGHT
Note: Pole not included All-In-One is an intelligent outdoor lighting system. It combines a high efficiency solar panel,
controller, high-capacity lithium-ion battery and LED light source into a compact housing.
Smaller, lighter, higher efficiency and easier installation.
Code AI-5L-8N
Solar Panel 15.6W Polycrystalline
LED Power 9W / 900lm
Battery 3.7V / 26000mAh Lithium
Control Mode Daylight Switching
Light Output 5hrs @ 100% then 25% until dawn
Endurance 3 nights when fully charged
Size Ø526 x 163mm
Features
• Easy Installation. No cabling required • Modular design
• Lithium-ion battery inside to extend product life • Compact and light weight design
• Light output automatically controlled • Rustproof, dustproof and waterproof
DC APPLIANCES
DC TV DC Ceiling Fan DC Fan DC Fridge/Freezer
Code JY-60-TV SLE-F2001HD SF-D6609 SLA-0145
Rated Power - 20W 16W 45W
Voltage 12VDC 12VDC
Specifications 12VDC/ 230VAC 12/ 24VDC
15" Colour LCD TV Metal construction 9" inch, aluminium, chrome 45lt capacity, temperature
103 Antenna not included 3 blades, 1 speed 3 blades, 2 speed
-10°C to 18°C
SOL2
SOLAR BATTERY CHARGERS
SOL2
Code SLP10F-12 SLP20F-12 SLP80F-12 SLP120F-12
Max Power 10W 20W 80W 120W
Voltage Pmax (Vmp) 17.0V 17.2V 17.2V 17.2V
Current Pmax (Imp) 0.58A 0.87A 4.56A 6.98A
Open Voltage (Voc) 21.6V 21.6V 22.84V 22.89V
Short Circuit Current 0.68A 0.96A 5.17A 7.72A
Package Size
302 x 357 x 30mm 576 x 357 x 30mm 720 x 150 x 635mm 1070 x 610 x 140mm
SOL2
FOLDABLE / FLEXIBLE SOLAR PANELS Semi-Rigid
Code
Max Power Foldable SLP10F-12A
Voltage Pmax (Vmp) 10W
Current Pmax (Imp) SHB-10W SHB-20W SHB-50W 17.0V
Open Voltage (Voc) 0.61A
Short Circuit Current 10W 20W 50W 21.8V
Package Size 17.42V 17.46V 17.7V 0.69A
0.57A 1.18A 2.87A
21.2V 21.6V 21.8V 350 x 30 x 358mm
0.62A 1.29A 3.1A
220 x 320 x 40mm 220 x 320 x 40mm 360 x 450 x 60mm
Flexible Semi-Rigid
Code SLP20F-12A SLP30F-12A SLP40F-12A SLP50F-12A
Max Power 20W 30W 40W 50W
Voltage Pmax (Vmp) 17.4V 17.4V 17.6V 17.7V
Current Pmax (Imp) 1.25A 1.67A 2.5A 2.95A
Open Voltage (Voc) 21.8V 21.9V 22.6V 22.8V
Short Circuit Current 1.41A 1.78A 2.89A 3.5A
Package Size 350 x 30 x 358mm 375 x 30 x 635mm 375 x 30 x 795mm 475 x 40 x 955mm
GEL DEEP CYCLE SOLAR BATTERIES
AGM / Gel Deep Cycle Solar Batteries 10 Year Turbular Gel Batteries OPZV-Range
Design Life
• Reduce Cell failure due to premature NSB-Range Cycle Life at Different DOD for 12V • Tubular positive plates *Battery
dry-out • Pasted negative plates Stand
• ABS Containers & Lids Excluded
• Extend cycle service life by reducing • One way relief valve
plate corrosion • 15 - 18 Years Service Life
• Gelled Thixotropic Electrolyte @ 20% DOD
• 10 year service life
Code Type Nominal Voltage Ah@C20 Ah@C10 Ah@C5 Terminal Type Size (mm) Weight (kg)
12V 70 65 52 M8 305 x 167 x 183 22.5
NSB065-12 AGM / Gel Deep Cycle 12V 110 100 80 M8 407 x 174 x 233 31.5
12V 220 200 160 M8 522 x 240 x 240 62.4
NSB100-12 AGM / Gel Deep Cycle 12V 260 250 215 M8 520 x 268 x 225 71 SOLAR
2V 765 710 660 M8 695 x 206 x 145 56
NSB200-12 AGM / Gel Deep Cycle 2V 1020 950 880 M8 695 x 210 x 191 76
2V 1275 1190 1100 M8 695 x 210 x 233 92
NSB250-12 AGM / Gel Deep Cycle 2V 1530 1425 1320 M8 695 x 210 x 275 110
2V 1890 1760 1632 M8 845 x 210 x 275 136
OPZV-600-2 Tubular Gel 2V 2520 2350 2176 M8 812 x 212 x 397 185
2V 3155 2935 2720 M8 812 x 212 x 487 224
OPZV-800-2 Tubular Gel 2V 3785 3525 3264 M8 812 x 212 x 576 269
OPZV-1000-2 Tubular Gel
OPZV-1200-2 Tubular Gel
OPZV-1500-2 Tubular Gel
OPZV-2000-2 Tubular Gel
OPZV-2500-2 Tubular Gel
OPZV-3000-2 Tubular Gel
SOSLOL 104
SOLAR PV MODULES
AC/DC offers a range of Polycrystalline panels designed for both On‐Grid and Off‐Grid applicatons.
All panels are constructed using the highest quality components and are CE certified according to the IEC61215:1995 standard.
All AC/DC panels are covered by our 25 year warranty.
(Poly) Multicrystalline PV Module (Lower cost)
Code Maximum Voltage @ Current @ Pmax Open-Circuit Short-Circuit Dimensions
Power (Pmax) Pmax (Vmp) (Imp) Voltage (Voc) Current (Isc) LxWxH
17,2V 0,29A 21,60V 0,31A
SLP005-12 5W 17,3V 0,58A 21,70V 0,61A 290 x 190 x 15mm
17,7V 1,13A 21,70V 1,21A 290 x 350 x 18mm
SLP010-12 10W 17,7V 1,70A 22,00V 1,78A 505 x 350 x 25mm
17,8V 2,25A 22,10V 2,37A 495 x 512 x 25mm
SLP020-12 20W 17,8V 2,81A 22,00V 3,02A 488 x 670 x 30mm
17,9V 3,35A 22,10V 3,55A 588 x 670 x 30mm
SLP030-12 30W 17,8V 4,49A 21,90V 4,78A 695 x 670 x 30mm
17,5V 5,14A 21,70V 5,58A 908 x 670 x 30mm
SLP040-12 40W 17,7V 5,65A 22,00V 5,93A 1005 x 670 x 35mm
17,8V 6,74A 22,10V 7,09A 1115 x 670 x 35mm
SLP050-12 50W 17,9V 7,82A 22,00V 8,31A 1325 x 670 x 35mm
27V 5,00A 32,60V 5,50A 1482 x 670 x 35mm
SLP060-12 60W 25,8V 6,59A 32,29V 7,24A 1020 x 992 x 35mm
26,5V 6,79A 32,60V 7,21A 1265 x 990 x 35mm
SLP080-12 80W 28,5V 7,34A 35,60V 7,90A 1330 x 990 x 35mm
30,1V 7,97A 36,70V 8,50A 1640 x 992 x 40mm
SLP090-12 90W 34,9V 7,44A 43,70V 8,18A 1640 x 992 x 40mm
35,2V 7,67A 43,60V 8,20A 1956 x 992 x 40mm
SLP100-12 100W 35,8V 7,82A 44,00V 8,32A 1956 x 992 x 40mm
36V 8,06A 43,56V 8,71A 1956 x 992 x 50mm
SLP120-12 120W 37,5V 8,00A 45,20V 8,69A 1956 x 992 x 50mm
1956 x 992 x 50mm
SLP140-12 140W 22,14V 5,46A
22,63V 5,84A 1195 x 541 x 35mm
SLP135-24 135W 45,00V 5,35A 1195 x 541 x 35mm
45,07V 5,84A 1580 x 808 x 40mm
SLP170-24 170W 45.6V 9.03A 1580 x 808 x 40mm
1956 x 992 x 45mm
SLP180-24 180W
SLP210-24 210W
SLP240-24 240W
SLP260-24 260W
SLP270-24 270W
SLP280-24 280W
SLP290-24 290W
SLP300-24 300W
Monocrystalline PV Modules
SLP090S-12 90W 18,54V 4,86A
18,83V 5,31A
SLP100S-12 100W 36,1V 4,99A
37,73V 5,30A
SLP180S-24 180W 37.7V 8.49A
SLP200S-24 200W
SLP320S-24 320W
Mechanical Characteristics
Solar Cells: Multicrystalline or Monocrystalline Solar cells
Construction: Front High-Transmission 3.2mm Tempered Glass; Encapsulate: EVA; Back: TPT
Frame: Clear Anodized Aluminium Alloy (Silver colour)
Module Warranty
• 25 year Limited Warranty of 80% Power Output;
• 10 year Limited Warranty of 90% Power Output;
• 10 year Limited Warranty of materials & workmanship
CIS THIN FILM SOLAR PANELS
SOLAR Dimensions: 1257 x 977 x 35mm
Weight: 20kg
Maximum Load: 2400Pa
Highlights of CIS Technology Code SF1505-CIS
• Production output in unfavourable conditions
• Excellent low light performance Nominal Power 150W
• Light soaking effect raises output after installation Open Circuit Voltage 108,0V
• High shadow tolerance Short Circuit Current 2,20A
• High temperature stability Current at Nominal Power 1,85A
• Aesthetically pleasing black appearance Voltage at Nominal Power 81,5V
105 SOL
PMW SOLAR CHARGE REGULATORS
Electronically regulated charging: Boost and float charge, Deep discharge protection PWM regulation. Fully electronically protected: Panel surge, wrong
polarity at the panel or battery, overload and short circuit at load. CML Range: Automatic 12/ 24 Volt detection, boost, equalize and float charging
4 LED Indications: c/w Built-in Day/
Charge Status, Night Sensor
SOC, LVD,
Overload / Short
Circuit
Code CA-08 CML-05 CML-08DS CML-10 CML-20 CML-2S0LC-NR24*
Max module current 8A 5A 8A 10A 20A 10A / 20A (*Add to Code)
Max load current 8A 5A 8A 10A 20A 10A / 20A
Voltage 12V 12 / 24V 12 / 24V 12 / 24V 12 / 24V 12V / 24V
Display 2 x LED, 1 x Duo-LED 2 x LED, 1 x Duo-LED 2 x LED, 1 x Duo-LED 2 x LED, 1 x Duo-LED 2 x LED, 1 x Duo-LED LED
Self consumption <4mA <4mA <4mA <4mA <4mA <15mA
Dimensions 80 x 100 x 32mm 80 x 100 x 32mm 80 x 100 x 32mm 80 x 100 x 32mm 80 x 100 x 32mm 168 x 88 x 34mm
ECO PWM CHARGE REGULATORS
The SLX range of solar controllers are optimally suited for inverter systems. The charging can be individually set up by using four buttons behind the front
casing. Multi-stage charging technology + PWM control. Integrated self test function.
LCD Indications: SLX-10 SLX-20 SLX-30 SLX-40 SLX-4*
Battery Voltage
PV Wattage 10A 20A 30A 40A *10A / 40A (Add to code)
Charge Current 10A 20A 30A 10A 10A / 40A
12 / 24V 12 / 24V 12 / 24V 12 / 24V 48V
Code < 47VDC < 47VDC < 47VDC < 47VDC < 47VDC
LCD LCD LCD LCD LCD
Max module current 12.5mA 12.5mA 12.5mA 12.5mA 25mA
Max load current 187 x 95 x 44mm 187 x 95 x 44mm 187 x 95 x 44mm 187 x 128 x 49mm
Voltage 187 x 128 x 49mm
Max Voc
Display
Self consumption
Dimensions
SOLAR MPPT CHARGE REGULATORS
iTracer is an industrial grade product with advanced Maximum Power Point Tracking (MPPT) algorithm. It can deliver the maximum available power for
charging batteries and charge a lower nominal voltage battery from a higher nominal voltage array. It can be applied in the off-grid PV systems up to 3.2kW.
The die-cast aluminium design ensures excellent heat dispersion.
Code IT3415ND-30 IT4415ND-45 IT6415ND-60 Features
Rated Battery Current 30A 45A 60A • Advanced MPPT algorithm with tracking
Rated Load Current 30A 45A 60A efficiency of 99%
Nominal System Voltage 8 - 72V • Multi-phase synchronous rectification technology
Max PV Open Circuit V 150V 800W realizing peak conversion efficiency 98%
Peak Conversion Efficiency 98% 1600W • Dual-core (ARM CPU+DSP) control architecture
600W 2400W improves the system response speed and optimizes the
Max PV Input Power: 12V 400W 1200W 3200W performance of the system SOLAR
24V 800W 1800W 440x231x110 • Multi-phase control technology, optimizes charging
36V 1200W 2400W 5.9kg current smoothness, reduces ripple and improves the
48V 1600W 382x231x107 system efficiency
358x219x102 4.6kg • Diversified load control mode
Dimensions (mm) 3.7kg • Programmable battery management parameters
Net Weight • Built-in running data and event logging (Max 15 months)
• Extensive communication capabilities (RS232, RS485
Accessories with Modbus protocol, CAN Bus extendable)
Code RS485-USB • PC software available for real time monitoring and
Description PC Communication Cable RS485 to USB parameter setting
• Field upgradable firmware
SOL2 106
SOLAR CHARGE REGULATORS
The BlueSolar range includes both MPPT & PWM type charge controllers. Ultra fast maximum power point tracking (MPPT) will improve energy harvest by
up to 30% compared to PWM charge controllers. Pulse width modulation (PWM) charge controllers offer lower cost solutions with 3-stage battery charging
and comprehensive protection.
PWM Lite PWM Pro
Code BLUESOLAR-5 BLUESOLAR-10 BS-PRO-10 BS-PRO-20 BS-PRO-30
Rated charge current 5A 10A 10A 20A 30A
Max. load current 10A 10A 10A 20A 30A
Battery Voltage
Control method 12/24V (Auto) 12/24V (Auto) 12/24V (Auto) 12/24V (Auto) 12/24V (Auto)
Max. solar voltage PWM PWM PWM PWM PWM
Dimensions
Temperature Sensor 28/55VDC 28/55VDC 28/55VDC 28/55VDC 28/55VDC
70 x 133 x 34mm 70 x 133 x 34mm 138 x 70 x 37mm 160 x 82 x 48mm 200 x 100 x 57mm
- - BS-PRO-TC BS-PRO-TC BS-PRO-TC
Code BS-MPPT-75/15 BS-MPPT-100/15 BS-MPPT-100/50 BS-MPPT-150/70 BS-MPPT-150/85
Rated charge current 15A 15A 50A 70A 85A
Max. load current 15A 15A – – –
Battery Voltage
Control method 12/24V (Auto) 12/24V (Auto) 12/24V (Auto) 12/24/36/48V (Auto) 12/24/36/48V (Auto)
Max. solar voltage MPPT MPPT MPPT MPPT MPPT
Dimensions 75VDC 100VDC 100VDC 150VDC 150VDC
VWB-CCGX 100 x 113 x 40mm 100 x 113 x 47mm 130 x 186 x 70mm 350 x 160 x 135mm 350 x 160 x 135mm
107 COLOUR CONTROL GX
The Colour Control (CCGX) provides intuitive control and monitoring for all Victron products connected to it.
Besides monitoring and controlling products connected to the Colour Control, Information can also be
forwarded to the free remote monitoring website.Visit www.vrm.victronenergy.com to try the free demos.
The CCGX has endless possibilities and features, that will be added to with free updates as they become
available.
Code CCGX
Supply Voltage 9 - 70VDC
Current Draw Max 245mA/12VDC, 125mA/24VDC, 65mA/48VDC
Output 1 x NO relay 3A /230VAC-30VDC
Comm Ports 2 x VE Direct, 2 x VE Can RJ45, 2 x VE Bus RJ45, 2 x USB,
SOLAR 1 x Ethernet 10/100/1000MB RJ45
Interface Modbus TCP
Dimensions 130 x 120 x 28mm
VWB-CCGX/BMV Accessories Description
CAN-USB Interface
Code MK2-USB Interface
CAN-USB VED-USB Cable
MK2-USB VE.Direct Cable
VED-USB Wall Mount Exclosure for CCGX
VED-CABLE Wall Mount Exclosure for CCGX & BMV Battery Monitor
VWB-CCGX
VWB-CCGX/BMV
SOL
PURE SINE WAVE INVERTERS
SOL2 Code 12V CZ-150S-12 P300-12-2 P600-12-2 P1000-12-2 P1500-12-2 P2000-12-2 P3000-12-2 BP4000W-12 BP5000W-12 BP6000W-12
Pure Sine Code 24V - P300-24-2 P600-24-2 P1000-24-2 P1500-24-2 P2000-24-2 P3000-24-2 BP4000W-24 BP5000W-24 BP6000W-24
Code 48V - P300-48-2 P600-48-2 P1000-48-2 P1500-48-2 P2000-48-2 P3000-48-2 BP4000W-48 BP5000W-48 BP6000W-48
Rated Power 150W 300W 600W 1000W 1500W 2000W 3000W 4000W 5000W 6000W
Surge Power 300W 600W 1200W 2000W 3000W 4000W 6000W 8000W 10 000W 12 000W
Output 230V 50/60Hz ± 3% Pure Sine Wave
Soft Start - 5V 500mA Yes
USB N/A
Protection Battery Low Voltage Alarm & Shutdown, Overload, Over Temperature, Over Voltage, Short Circuit, Reverse Polarity, Earth Leakage
Dimensions(mm) 180x105x60 260x150x58 260x150x78 293x150x98 405x230x108 460x230x108 465x200x145 518x200x145
Inverter / Charger - With Automatic Changeover Inverter / Charger
Code 12V - - CPS600-12-2 CPS1000-12-2 CPS1500-12-2 CPS2000-12-2 BP3000W-12 - - -
Code 24V - - CPS600-24-2 CPS1000-24-2 CPS1500-24-2 CPS2000-24-2 BP3000W-24 BP4000W-24 - -
Code 48V -
-- - - - BP3000W-48 BP4000W-48 BP5000W-48 BP6000W-48
Charger Size - - 12V/10A, 24V/5A 12V/15A, 24V/8A 12V/30A, 24V/15A, 48V/10A
PURE SINE WAVE INVERTERS
A true sine wave inverter with optimized efficiency. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in
weight and capable of supplying power, problem-free to any load. A unique feature is very high start up power.
Phoenix Inverters
Code 12V GX-12/180 GX-12/350 GX-12/800 GX-12/1200 GX-12/3000 -
Code 24V GX-24/180 GX-24/350 GX-24/800 GX-24/1200 GX-24/3000 GX-24/5000
Code 48V - GX-48/350 GX-48/800 GX-48/1200 GX-48/3000 GX-48/5000
Max. Power (25°C) 180VA/175W 350VA/300W 800VA/700W 1200VA/1000W 3000VA/2500W 5000VA/4500W
Peak power 350W 700W 1600W 2400W 6000W 10000W
Input DC range 10.5 - 15.5VDC / 21 - 31VDC / 42 - 62VDC 9.2 - 17.3VDC / 18.4 - 34VDC / 36.8 - 68VDC
Output voltage 230VAC +/- 3% 50Hz or 60Hz +/- 0,1%
No. Load Consumption 2.6W / 3.8W 3.1W / 5W / 6W 6W / 5W / 4W 6W / 5W / 6W 15W / 15W / 16W 25W / 25W
Battery connection Screw terminals 2+2 M8 Bolts
Dimensions (mm) 72x132x200 72x155x237 108x165x305 108x165x305 362x258x218 444x328x240
Features • Extra start-up power • Self diagnostic function • Remote on/off switch • 3000/5000VA models allow for
• Low Battery Protection • LED fault diagnosis • Input/output protection parallel or three-phase operation
INVERTER / CHARGER WITH AUTOMATIC CHANGEOVER
Type Multiplus Quattro
-
Code 12V MPIC-12/2000/80 MPIC-12/3000/120 - -
Code 24V -
Code 48V - MPIC-24/3000/70 - QIC-48/10000/140
Cont Power @ 25deg 9000W
Peak Power 2000VA/1600W MPIC-48/3000/35 MPIC-48/5000/70 20000W
4000W
Power Control 3000VA/2500W 5000VA/4500W 100A
Power Assist 30A
Transfer Switch 6000W 10000W 140A
Output 80/50A 2 x 100A
Charger 30A Yes
Max Feedthrough Current 1 3
Programmable relay Yes SOLAR
12/24V = 16A; 48V = 50A 100A
230VAC +- 2% 50Hz+-0.1% Pure Sine wave
120/70/35A 70A
1 x 16A / 1 x 50(48V) 1 x 100A
11
The MultiPlus & Quattro inverters are powerful true sine wave inverters. A battery charger that features adaptive charge technology. A high-speed AC transfer
switch in a single compact enclosure. • Two AC Outputs
Programming Description • Three phase capability
Code • Virtually unlimited power thanks to parallel operation
• PowerControl - Dealing with limited generator or grid power
VIC-PRO Programming of System Parameters • PowerAssist - Boosting the capacity of mains or generator power
SOL 108
INVERTER / CHARGER WITH AUTOMATIC CHANGEOVER
SOL This home solar inverter system incorporates features such as overload protection, short circuit protection and a DC cold
start function. The inverter is designed for 24 hour operation. Pure sine wave, 230VAC output.
Code HU-103 HU-203 HU-303 HU-503 HU-603 HU-803
Max.Con power 1.2kVA / 800W 2.4kVA / 1600W 3.6kVA / 2400W 5kVA / 4000W 6kVA / 6000W 8kVA / 8000W
Input Voltage Range 120 - 270VAC
Input DC Range 12VDC 24VDC 24VDC 48VDC 48VDC 48VDC
Output Voltage 220 / 230 / 240VAC Re-Settable via LCD Display
Output Current 3.5A 7A 10A 17A 26A 35A
Battery Charger >40A >50A >50A >60A >60A >60A
NB: Dimensions (mm) 298 x 400 x 150 298 x 450 x 190 298 x 450 x 190 415 x 600 x 260 415 x 600 x 260 415 x 600 x 260
Requires External
Solar Controller Specifications • Pre-Settable parameters • High efficiency design • Self-diagnostic function
• Input/ output protection
• Multi stage charger • Removable LCD Display
EASYSOLAR - HYBRID GRID INTERACTIVE SOLUTION
EasySolar combines MPPT solar Type EasySolar 1600VA EasySolar 3000VA
charger and inverter/charger in Code 12V
one enclosure. Batteries can be Code 24V ESIC-12/1600/70 ESIC-12/1600/40 - -
charged with solar power and/or Code 48V
with AC power (inverter/charger) Transfer Switch - - ESIC-24/3000-70 -
from the grid. Power Assist
technology protects the utility Input Voltage DC - - - ESIC-48/3000-35
from being overloaded by adding Output Voltage
extra inverter power as required. Max Power (25°C) 16A 16A 50A 35A
Batteries are protected from Peak Power 9.5-17V 19-33V 38-63V
overheating by over temp. Inverter
sensor. Input Voltage AC 19-33V
Charger Current
Programmable Relay 230VAC ± 2% 50Hz ± 0.1% 230VAC ± 2% 50Hz ± 0.1%
MPPT Controller 1600VA / 1300W 3000VA / 2500W
Max Output Current
Max PV Power 3000W 6000W
No. of PV Strings
Mains Charger
EasySolar 1600 SOL 187 - 265V / 45-65Hz 187 - 265V / 45-65Hz
Programming 70A 40A 70A 35A
Code Description Yes Yes Yes Yes
VIC-PRO Programming of System
Parameters Solar Charge Controller
100V / 50A 100V / 50A 2 x 100V / 50A 2 x 150V / 35A
2 x 35A
50A 50A 2 x 50A
2 x 2000W
700W 1400W 2 x 1400W 6
3 36
MODIFIED SINE WAVE INVERTERS
Modified
Sine
Code 12V PM-A-0150AH12 PM-A-0300AH12 PM-A-0600AH12 PM-A-1000AH12 PM-A-1200AH12 PM-A-1500AH12 PM-A-2500AH12 PM-A-3000AH12
Code 24V - - PM-A-0600AH24 PM-A-1000AH-24 PM-A-1200AH2 PM-A-1500AH2 PM-A-2500AH24 PM-A-3000AH24
Max continu- 150W 300W 600W 1000W 1200W 1500W 2500W 3000W
SOLAR ous power
Peak power 300W 600W 1200W 2000W 1400W 2000W 4200W 4800W
Output Amps 0.6A 1.25A 2.5A 4.16A 5A 7A 10.4A 10.4A
Size (mm) 115 x 101 x 63 189 x 101 x 63 245 x 176 x 85 360 x 236 x 83 330 x 275 x 110 480 x 275 x 110 510 x 275 x 110 330 x 220 x 140
Code 12V with charger PM-A-0700CA12 PM-A-1000CA12 PM-A-1200CA12 PM-A-1500CA12 PM-A-2500CA12 -
Code 24V with charger PM-A-0700CA24 PM-A-1000CA24 PM-A-1200CA24 PM-A-1500CA24 PM-A-2500CA24 -
Specifications Features
• AC Output voltage 230VAC • Overload protection
• Regulations ± 0.5% • DC Input/ AC Output short circuit protection
• Frequency 50Hz ±1% • All inverters supplied with cables
• Low voltage shut down 12/ 24 9.8V/ 19.12V • Cooling Fan
109 SOL2
ECONOMY MODIFIED SINE WAVE INVERTERS
BC1
Code OP-W150 OP-W450 OP-W450C OP-W600 OP-W800 OP-W800C
Wattage 150W 450W 450W 600W 800W 800W
Input Voltage 10 - 14VDC 10 - 14VDC 10 - 14VDC 10 - 14VDC 10 - 14VDC 10 - 14VDC
Output Voltage 165 - 270VAC 180 - 255VAC 180 - 240VAC 180 - 255VAC 180 - 255VAC 180 - 240VAC
Battery Charger
Dimensions (mm) N/A N/A 12A Max N/A N/A 12A Max
197 x 100 x 160 235 x 430 x 150 235 x 430 x 150 235 x 430 x 150 235 x 430 x 150 235 x 430 x 150
AUTOMATIC TRANSFER SWITCHES IP54
Designed to automatically switch between different power sources such as Mains supply - Generator / Inverter -
Generator / Mains supply - Inverter. The transfer switch has 2 x inputs and 1 x output.Input 1 has time delay 10 secs
adjustable. 1 x Aux contact 240VAC/20A.
Code Power Voltage Current Transfer Time
VETS-5KVA 5KVA 200-250VAC Input 1 Input 2 Output Closing Opening
VETS-10KVA 10KVA 200-250VAC 20A 20A 20A 10-20ms 5-10ms
40A 40A 40A 10-20ms 5-10ms
PV JUNCTION BOXES
Off Grid PV String Box
Code STRB-PWM-* STRB-01 STRB-02 STRB-04 STRB-06
PV input voltage 55VDC 150VDC 150VDC 150VDC 150VDC
4 6
PV Input string no. 1 1 2 20A 20A
80A
Maximum current/string *5/8/10/20/30/40A 20A 20A 120A
Protection output current 5/8/10/20/30/40A 20A 40A
* Add String Current to Code: 5/8/10/20/30/40A
• Separate fuse protection for each string on positive and negative
• STRB-PWM Includes: PV Isolation & Fuse Protection only
• STRB-01/02/04/06: PV Surge Protection and Isolation included PST25PV
PV String Box PV-JBOX16 Characteristics
Code • Equipped with PV dedicated
PV input voltage <1000V surge arrestor
PV Input string no. 16 • With function or arrestor failure alarm
Maximum current/string 10A • Including RS 232/485 Communication interface
Protection level IP65 Note: Incl. DIN mount 24VDC
Communication mode RS-485, RS-232 1.25A Power Supply
String Boxes for Grid-Tied Systems - IP65
High voltage string boxes are enclosures where PV arrays are electrically
connected and where the isolation function is performed in order to permit
maintenance work to be done. Junction boxes are supplied complete with
fuse, surge and overload protection.
According to Standards SOLAR
• IEC 60634-7-712 • IEC 60943-7-3 • EN 61439-1-2 • IEC61643-11
NB: GRP= Glass Reinforced Polyester
Code Strings Voltage Isc Surge Protection Material Size (mm) Gland Size
ST039025P 3 1000VDC 25A PST31PV ABS/PC 225 x 305 x 130 M12 / M16
ST049025P 4 1000VDC 25A PST31PV GRP 285 x 380 x 185 M12 / M16
ST068060P 6 800VDC 63A PST31PV GRP 285 x 570 x 185 M12 / M16
ST106080P 10 600VDC 80A PST31PV GRP 380 x 570 x 185 M12 / M16
ST148012P 14 800VDC 125A PST31PV GRP 380 x 760 x 225 M12 / M16
SH161012 16 1200VDC 160A PST31PV GRP 760 x 380 x 225 M12 / M16
SOL 110
GRID TIE HOME SOLAR SETS
Solar Frontier home based grid tie solar systems are designed with precisely matching components for maximum
output and efficiency using the latest CIS thin film technology solar panels and highly efficient Solar Frontier inverters.
Grid tie solar systems are designed with the aim of working in conjunction with your utility supply to offset your usage
from the utility by making use of solar power before utility power and feeding excess power back into your local grid.
Code Capacity No. of No. of DC Cable Connectors Modules in Roof Area
Inverters Modules Series Required
SOLARSET 3.0 3.0kWp 50m 5 male / 5 female
SOLARSET 4.6 4.6kWp 1 x 3kW 18 50m 10 male / 10 female 6 23.4m2
SOLARSET 5.9 5.9kWp 50m 10 male / 10 female
2 x 3kW 28 Grid Inverter 7 36.4m2
Code
2 x 3kW 36 SF-WR-3000 6 46.8m2
• Mounting brackets not included - for Mounting Systems see page 120-121 Description
• Compatible electricity meter required 3kW Single Phase Grid Inverter
• South African prepaid meters are not compatible
• Web based monitoring available on requested
COMPLETE HYBRID SOLAR BACKUP SYSTEMS
Solar Junction Box
Solar Array with tile Grid Tie for Only
roof mounting frame HYBH-10KVA
Batteries with Inverter/Charger Load
Fuse Protection
MKS / Infini Series Inverter/Charger with Auto Change Over - Turnkey Solar Kits
System Type Single Phase Grid-Interactive Hybrid System 3 Phase Grid-Tied Hybrid System
Kit Only Code HYBH-1KVA HYBH-3KVA HYBH-5KVA HYBH-10KVA-A HYBH-10KVA-B
AC Output Voltage 800W 230VAC 4000W 230VAC (P-N) / 400VAC (P-P)
Max. Continuous Power 180 min 2400W 144 min
Backup Time@ full load 360 min 150 min 288 min 10,000W 10,000W
Backup Time@ half load MKS-1K 24VDC 300 min MKS-5K 48VDC
Inverter SLP240-24 x 2 MKS-3K-PLUS 48VDC SLP290-24 x 9 86 min 115 min
Solar Panels 480W SLP240-24 x 6 2,610W
Solar Array Pmax NSB200-12 x 2 1,440W NSB200-12 x 8 172 min 230 min
Batteries 200Ah @ 24VDC NSB250-12 x 4 400Ah @ 48VDC
Battery Bank Capacity 250Ah @ 48VDC INFINI-10K-48 INFINI-10K-48
SLP290-24 x 16 SLP290-24 x 24
4,640W 6,960W
NSB200-12 x 12 OP2V-800-2 x 24
SOLAR 600Ah @ 48VDC 800Ah @ 48VDC
Additional Installation Charge
Installation Code INST-HYBH-1KVA INST-HYBH-3KVA INST-HYBH-5KVA INST-HYBH-10KVA-A INST-HYBH-10KVA-B
Kit Includes • Solar Combiner Box & Isolator NOTE:
• Fuse protection for Batteries The kit contains the components required for most installations, but does not include
• Grid-interactive Hybrid Inverter • Solar Cable & Connectors site specific items like racking or cable routes. Different solar panel mounting systems
• Solar Panels • Battery Cables & Lugs are available on request - Installation Excluded.
• Solar Batteries • Battery Cabinet / Stand Cable supplied is based on general estimations and additional cables and lugs or
• Tile roof Mounting Kit connectors may need to be ordered. Installation charge is an estimated charge and
will be confirmed after site inspection and confirmation of the location of the site.
Estimated pricing is based on a standard installation in the Gauteng Area.
111 SOL
HYBRID GRID-INTERACTIVE INVERTERS
• Combines the functions of • Selectable Input Voltage
Inverter, MPPT Solar Charger, • Cold Start Function
AC Battery Charger, UPS • Short Circuit Protection
• Input Voltage Selection
• MKS-4K and MKS-5K can be • Selectable Charger Current
connected in parallel and/or • Configurable AC / Solar Charge Priority
3Phase configuration • Mains or Generator Power
(parallelling unit built-in) • Overload / Over Temp Protection
• Smart Charge for Optimized Performance
• Pure Sine Wave Inverter
• Built in MPPT Controller
Code MKS-1K 24VDC MKS-1K 48VDC MKS-3K-PLUS 24VDC MKS-3K-PLUS 48VDC MKS-4K 48VDC MKS-5K 48VDC
4kVA / 3.2kW 5kVA / 4kW
Rated Power 1kVA / 800W 1kVA / 1000W 3kVA / 2.4kW 3kVA / 2.4kW 6kVA 6kVA
Surge Power
Input Volts 2kVA 6kVA 6kVA 48 48
Output Volts 60 60
230VAC
AC Charger / Battery 3KW 3KW
Battery Volts 230VAC 60 - 115VDC 60 - 115VDC
Max Charge Amps
24 48 24 48 145VDC 145VDC
Solar Charger 20 50 30 15 60 60
Max PV Power 600W 900W 1.5KW 3KW 6 x 290W 9 x 290W
8 x 200Ah 8 x 200Ah
MPPT Volt Range 30 - 66VDC 60 - 88VDC 60 - 115VDC 60 - 115VDC
Max PV VOC Volts 75VDC 102VDC 145VDC 145VDC
Max Charge Amps 25 18 60 60
Suggested Configuration to Provide 3 Hours of Back Up at 70% of Full Load Wattage
Solar Panels 2 x 240W 3 x 180W 6 x 240W 6 x 240W
Batteries 2 x 200Ah 4 x 100Ah 4 x 250Ah 4 x 250Ah
Web Connectivity
Code Description
MKS-WEB Web server to monitor and manage off-grid inverters in a network environment
GRID-TIED 3 PHASE HYBRID INVERTERS
Grid
Code INFINI-10K-48
• Combines Grid-tied Inverter, MPPT Solar Charger, AC Battery Charger, UPS
• Programmable supply priority for Grid, PV, Battery RS-485 Energy
Meter
• Programmable battery charging current
• Programmable operating mode: Grid-Tie, Off Grid, Grid-Tie with Backup PV Array
• Muliple comms options: USB, RS232, ModBus and SNMP
• Real time status display and control via software Modbus Card
• Built in timer for various modes of ON/OFF operation L1
L2
Grid
• True 3 phase output (230VAC P - N, 400VAC P - P) Hybrid L3
Inverter SOLARN
• Mains or Generator power
G
• Short Circuit Protection AC Output Main
Load
G N L3 L2 L1
• Overload / Over temp protection
• Rated Power: 10kW Battery
Priority Load
Hybrid Operation Off Grid Operation
PV Input AC Input
Nominal DC Voltage 720VDC Input Voltage Range 171 - 280 per phase
Max DC Voltage 900VDC Max AC Current Input 40A
MPPT Voltage Range 350-850VDC PV Input
Number of MPP Trackers 2
MPPT Voltage Range 350 - 850VDC
Max Input current 2 x 18.6A Number of MPP Trackers 2
Max Input Current 2 x 18.6A
Grid Output AC
Nominal Voltage 230VAC(P-N) / 400VAC(P-P) Battery Mode AC Output
Output Voltage Range 184-265VAC per phase
Nominal Voltage 230VAC(P-N) / 400VAC(P-P)
Nominal Output Range 14.5A per phase
AC Input Off Grid Operation
Input Voltage Range 170-280VAC PV input
Max AC Input Current 40A
Max PV Power Input 14.85kW
Battery Mode AC Output Nominal DC Voltage 720VDC
MPPT Voltage Range 350 - 850VDC
Nominal Output Voltage 230VAC(P-N) / 400VAC(P-P) Number of MPPT 2
Max Input Current 2 x 18.6A
Battery & Charger
Nominal DC Voltage 48VDC
Charge Current 10A-200A Adjustable Grid Tie Output
(Factory Default 60A)
Nominal Output Voltage 230VAC(P-N) / 400VAC(P-P)
SOL 112
SOLAR EDGE GRID-TIED SOLUTIONS
Fixed Voltage Inverter Safe DC Power Optimiser Multiple Orientations Cloud-based
Monitoring Platform
• Design Flexibility • Higher Power Yield • Lower O&M Cost, Efficient Monitoring • Enhanced Safety Solutions
The SolarEdge portfolio of products includes power optimizers, highly efficient PV inverters and a web portal for module-level monitoring and fault
detection. The SolarEdge system enables harvesting more solar power from any PV system by effectively removing the known system constraints across
the photovoltaic energy space.
SolarEdge Power Optimizer
The SolarEdge power optimizer is a DC/DC converter which is connected by installers to each PV module. The SolarEdge power optimizers increase
energy output from PV systems by constantly tracking the maximum power point (MPPT) of each module individually. Furthermore, the power optimizers
monitor the performance of each module and communicate performance data to the SolarEdge monitoring portal. Each power optimizer is equipped with
the unique SafeDC™ feature which automatically shuts down modules' DC voltage whenever the inverter or grid power is shut down.The MPPT per
module allows for flexible installation design with multiple orientations, tilts and module types in the same string. When working with SolarEdge Inverters,
SolarEdge power optimizers automatically maintain a fixed string voltage, allowing installers even greater flexibility with longer strings and strings of
different lengths in order to design optimal PV systems.The SolarEdge power optimizers have a 25 year warranty.
SolarEdge PV Inverter
The SolarEdge DC-AC PV inverter is specifically designed to work with the SolarEdge power optimizers. Because MPPT and voltage management are
handled separately for each module by the power optimizer, the inverter is only responsible for DC to AC inversion. Consequently, it is a less complicated,
more cost effective, more reliable solar inverter with a standard 12 year warranty, extendable to 20 or 25 years. The fixed string voltage ensures operation
at the highest efficiency at all times (>97% weighted efficiency) independent of string length and temperature.
SolarEdge PV Monitoring Portal
The SolarEdge PV Monitoring Portal is a web-based application that provides module-level, string-level and system-wide monitoring. The portal
automatically provides alerts for accurate and immediate fault detection, localized on a virtual site map for on-site and remote troubleshooting at the
module level. Module performance is communicated across existing power lines, so no extra wiring is required.
Single Phase Inverters
Code SE2200 SE3000 SE3500 SE4000 SE5000 SE6000 SE4000-16
2200W 3000W 3500W 4000W 5000W 6000W 4000W
Rated AC Power Output (Max) 220/230VAC
AC Output Voltage (Nominal) 12A 16,5A 19,5A 184-264.5VAC 27A 27A 16A
AC Output Voltage Range 2400W 3300W 3900W 50/60Hz ±5% 5500W 6600W 4400W
AC Frequency
Max Current Output 22A
Recommended Max DC Power 4400W
(module STC)
Max input voltage 8,5A 11,5A 13,5A 500VDC 19,5A 23A 15,5A
Nominal DC input voltage 350VDC
Max input current PV 15,5A
Support communication interface
RS485, RS232, ETHERNET, Zigbee (Optional)
Three Phase Inverters
Code SE7K SE8K SE9K SE10K SE12.5K SE15K SE16K SE17K
7000W 8000W 9000W 10000W 12500W 15000W 16000W 17000W
Rated AC Power Output (Max)
AC Output Voltage (Nominal) 11,5A 13A 14,5A 400/ 230VAC 23A 25,5A 26A
AC Output Voltage Range (L-N) 7700W 8800W 9900W 184-264.5VAC 16500W 17600W 18700W
Max Current Output 16A 20A
SOLAR
Recommended Max DC Power 11000W 13700W
(module STC)
Max input voltage 950VDC
Nominal DC input voltage
Max input current PV 750VDC
Support communication interface
12A 13,5A 15A 16,5A 21A 22A 23A 23A
Extended Warranty
RS485, RS232, ETHERNET, ZIGBEE or GSM (Optional see page 114)
Code* Description Safety Standard compliance Emissions
WE-1M-25
WE-1S-25 Extended warranty, single phase inverter 4 - 6kW IEC-62103 (EN50178), IEC-62109 IEC61000-6-2, IEC61000-6-3
WE-3H-25 Extended Warranty, single phase inverter <4kW
WE-3M-25 Extended warranty, three phase inverter 15 - 17kW Grid connection standards:
Extended warranty, three phase inverter 7 - 12.5kW
113 VDE 0126-1-1, VDE-AR-N-4105, AS-4777, RD-1663, IEC61000-3-11,
IEC61000-3-12, FCC part 15 class B, RoHS Yes
SOL
SOLAR EDGE GRID-TIED SOLUTIONS
Power Optimisers - Only for use with Solar Edge Inverters
Code OPA250-RV OPA300-LV OPA400-MV OPA400-EV
Rated Input DC Power 250W 300W 400W 400W
Absolute max Input Voltage
MPPT Operating range 47VDC 55VDC 75VDC 130VDC
Max Input Current
Max Output Current 5-47VDC 5-55VDC 5-75VDC 15-130VDC
Operating Output Voltage 10A 10A 12.5A 7A
Min Number Optimizers per String
Max Number Optimizers per String 15A
5-60VDC
8 (1Ph system)/ 16 (3Ph system)
Module power dependant: Maximum 25 (1Ph system)/ 50 (3Ph system)
Smart Energy Meter- To Enable Feed In Limitation
Code SE1000-CCG-G
SE-WNC-3Y-400-MB-K Watt node meter to enable feed in limitation
SE-ACT-0750-50 50A Split core CT for use with Watt node meter
SE-ACT-0750-100 100A Split core CT for use with Watt node meter
SE-ACT-0750-250 250A Split core CT for use with Watt node meter
SE-CTS-2000-1000 1000A Split core CT for use with Watt node meter
Control and Communication Gateway
Highlights Application Examples
• Analogue inputs accomodate a variety of environmental
sensors, including temperature, irradiance and wind
• Logs inverter monitoring data
• Power reduction interface - To enable
feed-in limitation
• Wireless connectivity - GSM or Zigbee wireless
connection options (see below)
• Interfaces to non-Solar Edge monitoring loggers
• Revenue meter connection
Code SE1000-CCG-G
Power Supply Included, 100-240VAC Number of analogue inputs 3
Supply Voltage 9 - 140VDC (2W)
Ethernet Interface 10 / 100 - BaseT Input 1 0-2V or 0-10V
Wireless Connection ZigBee Module (see below)
Power Reduction INT. 4 control pins, 5V, GND Input 2 0-20mV or 0-2V
RS232 Interface For local connection
Input 3 -20mA - 20mA
Supported RS485 Devices: Solar Edge devices, export inverter data, Revenue
meter, Exported Data to Non-Solar Edge Logger
GSM Modem
Solar Edge offers a GSM/ GPRS modem for wireless connectivity. The modem enables a wireless link between a master
inverter and the Solar Edge monitoring server using GSM cellular communication. GSM connectivity allows to effortlessly
connect remote installations to the monitoring portal.
Effortless Monitoring
• Connects wirelessly to the monitoring portal • Uses any available GSM network
• Easy installation, connects to serial port of master inverter or communication gateway • External antenna for strong reception
• European compliance
Code Description
SE1000-GSEG-20E GSM Modem, quad band c/w antenna
Wireless Communication Products
Solar Edge offers Zigbee products for wireless connectivity. These enable either a wireless mesh network between multiple inverters at a site, or wireless
link between a single inverter and a remote internet gateway point.
Interconnect with ease SOLAR
• Replaces either RS485 or Ethernet wiring
• External antennas for long or non-line-of-sight-links
• Interconnects inverters wirelessly
• Connects wirelessly between an inverter
and a remote internet gateway
• Zigbee unit installed within the inverter enclosure
for outdoor resilience
Code Description Functions
SE1000-ZB02-MST 1 Digi X-bee-Pro coordinator module, antenna (Master inverter) Inter-inverter communication
SE1000-ZB02-SLV 1 Digi X-bee-Pro coordinator module, antenna (Slave inverter) Inter-inverter communication
SE1000-ZB00-DG2-X 1 Digi Connect Port x2 gateway, 1 Digi X-bee-Pro router module, antenna Ethernet Gateway
SOL 114
GRID TIE INVERTERS
The Fronius IG Plus generation of inverters represents an evolution of the proven Fronius IG product family. Power categories from 2.6 to 12kW promise
suitability for every possible system size. With a maximum efficiency of 95.9%, the Fronius IG Plus range achieves one of the highest values for
transformer inverters. Fronius inverters always achieve maximum yield, even when in the partial-load range. This is all down to
the unique Fronius Master Inverter X-Change system (MIXTM). The "master" is allocated alternately, taking
into account the operating hours worked.
Fronius transformer inverters use a high-frequency (HF) transformer. The automatic transformer switchover
facility produces three efficiency peaks. The result: a constant level of efficiency across the entire input
voltage range, resulting in higher yields.
With the Fronius Datamanager, we offer a WLAN interface in the inverter itself. The inverter is connected to
the internet without additional cabling and grants you the perfect overview of how the PV system is
operating. (Optional)
Fronius inverters are ready for the Smart Grid of tomorrow. A series of smart functions, known as Advanced
Grid Features, are built into the devices. kfd
Single Phase Inverters
Code FIGP25V-1 FIGP30V-1 FIGP35V-1 FIGP50V-1 FIGP55V-1 FIGP60V-1
Input Data
DC maximum power at cos Ø=1 2740W 3170W 3710W 4260W 5260W 6320W
11.9A 13.8A 22.9A 27.5A
Max. input current (Idc max) 16.2A 18.6A
Max input voltage (Udc,1)
MPP voltage range (Umpp min - Umpp max) 600V
Number of DC inputs
230 - 500V
6
Output Data
AC nominal output (Pac, r) 2600W 3000W 3500W 4000W 5000W 6000W
Max. output power 2600VA 6000VA
11.3A 3000VA 3500VA 4000VA 5000VA 26.1A
Max. output current (Iac max)
Grid connection (Uac, r), (Uac min) - (Uac max) 13.0A 15.2A 17.4A 21.7A
General Data 1-NPE 230V, 180 - 270VAC (50/6-Hz)
Inverters Dimensions (HxWxD) 673 x 434 x 250mm 968 x 434 x 250mm
FRONIUS-DW Weight 23.8kg 36.9kg
FRONIUS-DM
FRONIUS-CC Degree of protection IP54
FRONIUS-PCBOX
FRONIUS-SBOX Three Phase Inverters FIGP55V-3 FIGP60V-3 FIGP80V-3 FIGP100V-3 FIGP120V-3 FIGP150V-3
FRONIUS-IS Code
FRONIUS-MT
FRONIUS-WS Input Data
FRONIUS-AT
DC maximum power at cos Ø=1 5250W 6300W 7360W 8430W 10590W 12770W
22.8A 27.5A
Max. input current (Idc max) 32.0A 36.7A 46.2A 55.6A
Max input voltage (U )
600V
dc,1
230 - 500V
MPP voltage range (Umpp min - Umpp max)
6
Number of DC inputs
Output Data
AC nominal output (Pac, r) 5000W 6000W 7000W 8000W 10000W 12000W
Max. output power 5000VA 6000VA 7000VA 8000VA 10000VA 12000VA
Max. output current (Iac max)
Grid connection (Uac, r), (Uac min) - (Uac max) 7.3A 8.7A 10.2A 11.6A 14.5A 17.4A
3-NPE 400V/ 230V, 180 - 270VAC (50/60Hz)
General Data
1.263 x 434 x 250mm
Dimensions (HxWxD) 49.2kg
Weight IP54
Degree of protection
SOLAR Accessories Datalogger for up to 100 inverters in real time. Inverters must be equiped with Com Card.
FRONIUS-DW Includes RS422, Ethernet and USB interfaces.
FRONIUM-DM Datamanager card enables inverters to be connected directly to the internet for remote monitoring and
control. Integrated web server. RS422, Ethernet and Wlan interfaces as well as Ripple control interface.
FRONIUS-CC Com Card - Network card each inverter requires for data communication with other Fronius devices.
FRONIUS-PCBOX Power control box. RS422 and Ripple control interface. Inverters must be equipped with Com Card.
FRONIUS-SBOX Sensor Box. Allows for collection of environmental data by connecting various sensors.
FRONIUS-IS Irradiation sensor c/w 3m cable
FRONIUS-MT Module temperature sensor c/w 3m cable
FRONIUS-WS Wind speed sensor, Pulse output. c/w 3m cable
FRONIUS-AT Ambient temperature sensor PT1000 c/w 3m cable
115 SOL
DC ISOLATORS
DC Rotary Isolator - DC21B
Code Code Din/ Rated Current Rated Voltage No of Poles Size (mm)
32A 600V 2P in Series HxWxD
Panel Mount Chassis Mount 60 x 47 x 90mm
BYS-1-2P BYS-2-2P
BYS-1-4P BYS-2-4P 32A 1200V 4P in Series 60 x 47 x 111mm
BYS-1-6P BYS-2-6P 32A 1500V 6P in Series 60 x 47 x 133mm
DIN Rail Mounting Modular DC Isolator - DC21B
Code Rated Current Rated Voltage No of Poles Din Width
2P in Series 2 modules
BB1H-63-2P 63A 600V
BB1H-63-4P 63A 1200V 4P in Series 2 modules
Moulded Case DC Isolator - DC21B
Code Rated Current Rated Voltage No of Poles Size (mm)
BDH-125 125A 1200V 4P in Series Hx WxD
151 x 123 x 114mm
BDH-250 250A 1200V 4P in Series 165 x 140 x 110mm
BDH-400 400A 1000V 4P in Series 259 x 199 x 153mm
DC Rotary Isolator - DC21B No of Poles Size (mm)
4P in Series H xW xD
Code Rated Current Rated Voltage 181 x 150 x 68mm
BH-250 250A 1000V
c/w Extension shaft and pistol grip handle
HIGH RATING DC ISOLATORS
Series 55DC / 55PV switch-disconnectors are manually operated
load break switches that provide safety isolation for any high voltage
DC circuit in photovoltaic applications.
According to Standards General Characteristics
• Visual indication of contact position
• IEC 60947-3 • High thermal and dynamic withstand
• IEC 60364-7-712 • Operational load duty categories
• EN 60947-3
• DIN VDE 0126 DC-21 and DC-22
• VDE 0660-107 (1992)
• IEC 60364-4-410 9 Series bridges, handle & shaft to be ordered seperately
Code 220VDC 400VDC 600VDC 800VDC 1000V
55DC4014 125ADC 125ADC 80ADC
55DC4026 250ADC 250ADC 125ADC 63ADC -
55PV4012 - - -
55PV4016 - - - 125ADC -
55DC4014 - 125ADC
1000VDC
8kV - 160ADC
Technical 55DC4026 55PV4012 55PV4016
Rated insulation voltage Ui 1000VDC 1000VDC 1200VDC
Rated impulse withstand voltage Uimp 8kV 12kV 12kV
Accessories For Specific Types Accessories For All types
Lockable Lockable Set of 2
200mm SOLAR
Type Internal External Series Bridge Terminal Shaft Extender Auxilliary Inter Phase
Handle Handle + Shaft Screen Contacts Barrier
55DC4014 26995042 41DC4014 26984012 14001020 (200m) 26990031 (1NO/1NC) -
55DC4026 55K1G200 41DC4026 14001025 (250m) 26990032 (2NO/2NC) -
55PV 26995052 26092025 26984020 14001032 (320m) 29980024
55K1G200 14001050 (500m) - -
26995052 26984020 -
55K1G200 116
SOL
DC ISOLATORS
Manually operated multiple load break switches that IP20 - Finger safe Series links mounted in factory
ensure safe on-load opening and closing of photovoltaic
circuits on small and medium systems.
• Double breaking mechanism
• Contacts in series to optimize electrical characteristics
• External series links mounted in factory
• Silver alloy contacts
Code Voltage A-5342PVO A-5362PVO A-5382PVO A-5102PVO
M5 M5
Connecting Screw - 10-25 M5 M5 10-25
Standard wire (mm2) - 10-16 10-25 10-25 10-16
4 10-16 10-16 4
Flexible (mm2) -
4 4 -
Impulse Voltage Uimp kV - -
-
Current ratings @ load duty category DC - 21 -
-
300VDC 35ADC - - 25ADC
400VDC - 25ADC -
500VDC - 20ADC - Double breaking
600VDC - 15ADC 25ADC mechanism avoids
800VDC - 10ADC arching due to high
1000VDC - - speed closing or
- opening, independant
of operator turning
speed and pressure.
Accessories
Code AK1200523 AK0100007 AK0000003 AK1740003
Description Padlockable operating DIN Rail mounting Base mounting plate DIN Rail mounting kit with extension
handle Plate shaft and door interlock.
DC COMPACT ENCLOSED ISOLATORS IP65
Enclosed DC Isolators that use standard MC4 connectors, making them extremely easy to install in PV installations.
General Characteristics Simple & fast plugin
• Original and compact design
• Base mounting
• Enclosure UV resistant
• Auxiliary contacts option
SOLAR
Code Padlockable Handle A-5362MC7 A-5382MC7 A-5102MC7
Description Available
PV switch isolator 25A @ PV switch isolator 25A @ PV switch isolator 25A @
117 A-5342MC7 400VDC/ 20A @ 500VDC 600VDC/ 16A @ 800VDC 1000VDC
PV switch isolator 35A @
(MC4 included) (MC4 included) (MC4 included)
300VDC
(MC4 included)
SOL
LIGHTNING & SURGE PROTECTION
Special Surge Protection for Invertors (e.g. Wind Turbines)
Code Class No. of Max. Up Uc Backup Network DIN
Poles MCB Width
Discharge
8/20µS
SLP-880V/3 2 3 40kA <3.2kV 880V 160A TN-S/TN-C/TT 3
Photovoltaic System Protection
Code No of Max Nominal Up Uc Uoc stc DIN Width
Poles Discharge
Discharge 8/20µS 0.8kV 170VDC
8/20µS 15kA 4.0kV 500VDC
3.6kV 350VDC
SLP-170PHV/2 2 40kA 20kA 250VDC 2
750VDC 2
SLP-500PHV/2 2 40kA 20kA 750VDC 3
1000VDC 3
SLP-700PHV/3 3 40kA
SLP-1000PHV/3 3 30kA 15kA 4kV 500VDC
Uoc stc refers to the maximum voltage of the photovoltaic panel
DC SURGE PROTECTION
Photovoltaic System Protection
Code Class No of Imax In Iimp Up Uc DIN Width Auxilliary
Poles 8/20 80/20 10/350
2.2kV 550VDC 2N
PST25PV 2 2 40kA 20kA - 3.0kV 1000VDC 3N
20kA - 1.9kV 1000VDC 3Y
PST31PV 2 3 40kA 40kA 12.5kA
PST41PV 1+2 2 -
PST25/31: Surge protection devices Class II are developed to protect PV Photovoltiac networks against atmospheric lightning. These
units must be installed in parallel on the DC networks to provide common and differential mode protection. The design is based on
high energy MOVs equipped with specific thermal disconnectors and related failure indicators.
PST41: Surge protector devices Class I are recommended for both ends of the DC power supply line. Due to their extraodinarily
high discharge capacity, they are recommended for use on installations with elevated risk of direct lightning strikes. The protection is
based on high energy MOVs and specific thermal disconnectors achieving a superior protection level and a lack of follow-up current.
1000VDC FUSES
10 x 38 1000VDC Fuse
Code Current Rating Power Loss Temperature Derating Curves
0.8In In
30F6PV 6A 1.1W 1.8W
30F8PV 8A 1.2W 2.1W
30F10PV 10A 1.3W 2.3W
30F12PV 12A 1.5W 2.7W
30F15PV 15A 1.7W 2.9W
30F20PV 20A 2.1W 3.6W
14 x 51 1000VDC Fuse
30F32PV 32A 3.3W 6.2W
A range of fuse links specifically designed for protection and isolation of photovoltaic strings. The fuse links
are capable of interrupting low overcurrents associated with faulted PV string arrays.
General Characteristics • Rated breaking capacity: 33kA (VDC)
• Rated Voltage: 1000VDC • Minimum interrupting rating 1.3 x In
• Time constant (L/R): under 1ms
1000VDC FUSEHOLDERS
Fuse Holders for DC Applications
Code Thermal Rating Fuse Size Poles Width SOLAR
211PV 20A 10 x 38 1 Pole 18mm
14 x 51 1 Pole 27mm
221PV 50A
Accessories
Code Description
21KE Multipole assembly kits
According To Characteristics
• IEC 60947-1 • 1000VDC - DC-20B
• IEC 60947-3 • Mounting 35mm DIN rail
• High temperature resistant plastics
• Elevated insulation characteristics For multipole fuse holders use multipole assembly kits - 21KE
SOL 118
ROOF/GROUND PV PANEL MOUNTING KITS (4 MODULES)
Ondulated Klip-Lock Trapezoidal
Tiled Roof Portrait Landscape
Kits contain Clamps, Supports, Profiles, Crossbeam Braces, Double Threaded Screws for the relevant installation
Code Description Contents
MK001 Tile Roof Mounting Kit (Adjustable support LS400540) 2 x LS145420, 4 x LS106500, 6 x LS106600, 8 x LS400540
MK002 Tile Roof Mounting Kit (Adjustable support LS340320) 2 x LS145420, 4 x LS106500, 6 x LS106600, 8 x LS340284
MK003 Corrugated Ondulated Tin Roof Mounting Kit 2 x LS145420, 4 x LS106500, 6 x LS106600, 8 x LS530210
MK004 Corrugated Trapezoidal Roof Mounting Kit (Side of profile mounting) 2 x LS145420, 4 x LS106500, 6 x LS106600,12 x LS500472
MK005 Corrugated Trapezoidal Roof Mounting Kit (Top of profile mounting) 2 x LS165420, 4 x LS106500, 6 x LS106600
MK006 Klip Lock Sheet Steel Roof Mounting Kit 2 x LS145420, 4 x LS106500, 6 x LS106600, 12 x LS700320
MK007 Flat Roof / Ground Mounting Kit (Portrait orientation) 2 x LS145420, 4 x LS106500, 6 x LS106600, 2 x LSCVP1650,
3 x LSTE14001530
MK008 Flat Roof / Ground Mounting Kit (Landscape orientation) 4 x LS145420, 4 x LS106500, 8 x LS106600, 2 x LSGLI145,
5 x LSTE11901530, 4 x LSCVP1650
SOLAR ROOF TILT RACKING SYSTEM
ACDC is continually developing kits to use with our panels. These kits are designed for the most rugged conditions and consist of the highest quality components.
SOLAR
Code GR-AD-FL GR-AD-FL 10/15 GR-AD-FL 15/30 GR-AD-FL 30/60
Description Front Support Rear Support: 10-15cm Rear Support: 15-30cm Rear Support: 30-60cm
* Use the following Parts Code: CK-FZ-F4200 (Solar Panel Profile) Specifications • High class aluminium alloy Al16005-T5 & stainless steel 304
• PV Modules: framed • Roof Slope: up to 60° • Suitable for pitched or flat roof
119 SOL
SOLAR MOUNTING SYSTEMS
Wind Speeds Up To 28m/s Wind Speeds Up To 36m/s
Code LS145420 LS165420 LS146420 LS156420
Description Universal Mounting Profile 4.2m Universal Mounting Profile 4.2m Solar Standard Rail 4.2m
Aluminium Double Height
Rail 4.2m
Code LS106600 LS106500 LS108500 LS108600
Description Universal Central Clamp
Pre-assembled Universal Pre-assembled Universal Pre-assembled Universal
Lateral (End) Clamp Lateral (End) Clamp Central Clamp
Pre-Cut at 380mm
Code LSGLI145 LS500472 LSGLI140 LS700160
Description Junction for Linear Connection Support for Trapezoidal Roof Junction for linear connection Bracket For Corrugated Sheet
Code LS700200 LS700320 LS500471 LS500450A
Description Support For Metal Roof Support For Corrugated Sheet
Stainless Steel Clamp for Universal Lateral Support For
Klip-Lock Roof Trapezoidal Metal Roof
Code LS700330 LS400540 LS340320 LS340284
Description Adjustable Roof Fixing Support Adjustable Roof Fixing Support Adjustable Fixing Support
Electro Galvanized Clamp for
Klip-Lock Roof
Code LS060185 LS530210 LSL-FL2030 LSGPU140
Description Aluminium Tin Hook Double Thread Screw 12 x 300 Adjustment Flange
Junction For Perpendicular
1400mm 1190mm Connections
Code LSCVP1650 LSTE14001530 LSTE11901530 LS100730-10 SOLAR
Description Clamp For Fixing Cables
Flat Aluminium Cross-Beam Adjustable light alloy floor support Adjustable Light Alloy Floor
Size: 40 x 4 x 1650mm 15o, 20o, 25o, 30o Support 15⁰, 20⁰ , 25⁰ , 30⁰
ElimTinhaetfet
Code AC700 B134-100 LS500531-100 LS500-S20-100
Description Stainless Steel Fixing Screw -100pc
Note: Self-Adhesive Sealing Tape 15m Burglar Sphere - 100pcs Aluminium Rivets - 100pcs Blue = Universal fittings
Orange = Wind speed up to 28m/s, Green = Wind speed up to 36m/s, 120
SOL
SOLAR MOUNTING SYSTEMS
We provide professional solutions for Solar photovoltaic mounting for residential, corporate and utility scale applications.
Features • Roof Top mounting: Tile, Tin & Tilt Tin/ tiled • Open area: Ground mounting/ pole mounting • Suitable for all roof types and PV modules
• Fast and simple installations • High quality material in Aluminium 6005-T5
Panel Mounting Section 1 Panel Mounting Section 2
BMF4001 BMF4110
Aluminium profile - 4m Positioning support
Code CK-FZ-F4200 CK-FZ-SK CK-FZ-AM CK-FZH-01
Adj Solar mid clamp Solar SUS304 Tile Hook
Description Solar standard rail 4.2m Solar standard rail splice
BMF4401
Adjustable Tile Hook BMF4402
Solar Panel Adjustable Tile Hook
Clamps
(packs of 10)
Code CK-FZH-013 CK-FZH-TC CK-FZ-AE CK-FZH-021 End End Clamp Middle Mid. Clamp
Adj end clamp Solar tin thin roof AL Clamp Code Code
Description Solar aluminium tin hook Solar tin roof AL Clamp Module Module
Thickness Thickness
BMF4021 34mm BMF4011 34 ÷ 37mm
BMF4022 35mm BMF4012 38 ÷ 42mm
BMF4023 36mm BMF4013 43 ÷ 47mm
BMF4024 38mm BMF4014 48 ÷ 50mm
BMF4025 40mm
Code CK-FZA-FL CK-TM-1530 CK-2V-3035 CK-FSC-CP1 BMF4026 42mm End Cap
Solar Cable Clips BMF4027 46mm BMF4008
Description Solar Adj front leg Solar Adj Tri structure 2V ground support 30/35° BMF4028 48mm (packs of 10)
BMF4029 50mm
15-30
Pre-Assembled Pole Bracket Stainless Steel Fasteners
Watts 1 Panel 2 Panel Code Description Pack
5-10W DM110 – BMF4004 BMF4006 BMF4004 M8 x 20 Hammer-headed screws 50
20W DM120 – BMF4005 BMF4303
40-60W DM175 DM275 BMF4006 M8 x 20 Hexagonal head screws 50
Galvanised BMF4005 M8 Self-blocking flanged nut 50
Pre-Assembled Triangle Bracket BMF4303 4,8 x 32 Self-tapping hex screws 100
Watts 1 Panel 2 Panel
60-120W BMF4301 –
170-270W – DR275
Bracing Bar Code BMF4002 BMF4501 BMF4003 BMF4100
Code Description Fixing Bracket Crimped Plate
Alluminium or BMF4302 4m Bar 13x6mm Alu. Profile Joint for Cover for gap
Galvanised BMF4001 between panels-4m
8 PANEL MOUNTING KITS
SOLAR Kits Includes CK-PM-08 CK-TL-08 CK-TNO-08 CK-ADJ-08
Pole Mounting Kit Tile Mounting Kit Tin Mounting Kit Tin-Tilt Mounting Kit
• Frame Work & Clamps
• Structure fixing
Bolts & Nuts
• Profile 4.2m
• Suited for 170-290W
Code
Description
Code CK-TNC-08 CK-GD-08 CK-UT-08 CK-V2-08
Description Tin-Clamp Mounting Kit Ground Mounting Kit Utility Ground Mounting Kit Tin-Tilt Mounting Kit
121 SOL
SOLAR OFF-GRID MOUNTING KITS
Solar SLB Series Off-Grid Mounts - Fit for 1 Panel
AC/DC Dynamics provides complete off-grid mounting kits. These kits include all brackets and
hardware needed to mount panels on any surface such as: walls, roofs, caravans, poles and etc.
Code SLB-0111 SLB-0112 SLB-0113 SLB-0102 SLB-0103
Module Frame 18mm 30/35mm 35mm 35mm 35mm
Mounting Holes 5.5mm x 8 3.5mm x 12 4.5mm x12
Module Power 5W 10 - 30W 4.5mm x 12 4.5mm x12 40 - 135W
Mounting Type Pole- Pole- Flat
Mounted Adjustable 40 - 135W 40 - 135W Surface
Adjustable
Wall, Vertical Fixed
Surface Bracket
Adjustable
SOLAR-FLEX ADHESIVE PV CONNECTORS IP67
Solar-Flex white - 290ml Features
Code WST-310SOL-WH • For connecting to panel contacts
• Durable and weather-resistant
Elastic one-component adhesive and sealant with fast • Modules protected by means of
development of adhesive strength. It contains no
substances that hinder the coating of laquer one or more diodes
(eg. silicone), no solvents and no isocyanate.
Solar-Flex has a very high initial adhesive strength and • Temperature Range:
also enables adhesive bonds on vertical surfaces indoors
and outdoors. For strongly stressed adhesive -40˚C - +90˚C
bonds in the following areas:
• UV-Resistant
• Solar Power systems;
• Junction Boxes; • High-quality contacts Code Description Cable Size
• Marking systems; • Material: Contact: CuSn PV panel box enclosure 2.5 - 10mm2
• Metalworking;
• Tank and apparatus construction; Casing: PC/PA 903709
• Ventilation and air conditioning
and wherever silicone or PV MC4 Female Branch Connector
products containing
silicone are unsuitable. For secure and easy connection of PV modules in parallel.
MFF= Male/ Female/ Female Connectors
Code Description Pack
905228-1 PV MC4 MFF Branch 1
PV MC4 Male Branch Connector
FMM= Female/ Male/ Male Connectors
Code Description Pack
905229-1 PV MC4 FMM Branch 1
Advantages PV MC4 Female Coupling Connector
• High initial adhesive strength on Code Core Cross Cable Ø mm Pack
vertical surfaces;
• Broad range of adhesion, even on PV-ST01/F1 2.5mm2 3-6 1
moist surfaces; PV-ST01/F2 4 - 6mm2 6.5 - 7.5 1
• Resistant to weathering and UV;
• Free of silicone, isocyanate and PV MC4 Male Coupling Connectors
halogen;
• Solvent-Free, odour-free, non- Code Core Cross Cable Ø mm Pack
corrosive;
• Sandable & can be painted over PV-ST01/M1 2.5mm2 3-6 1
even when wet.
PV-ST01/M2 4 - 6mm2 6.5 - 7.5 1
1000VDC UV Resistant PV MC4 Fly-Leads
See page 123 for Solar Cable Code Description
& Crimping Tools
SLE-1M 1m 4mm PV Cable(Black) MC Male & Female
SLE-2M 2m 4mm PV Cable (Black) MC Male & Female
P3 SLE-5M 5m 4mm PV Cable (Black) MC Male & Female
SLE-10M 10m 4mm PV Cable (Black) MC Male & Female SOLAR
SOLAR MODULE ANALYSER
Code PROVA200 PROVA300XP
Description Analyser Printer
• Voltage Range: 0-60VDC • Maximum solar power (Pmax)search • Voltage at open circuit (V-open)
• Current Range: 0-6A by Auto-scan (60V, 6A) • Current at short circuit
• I-V Curve test for solar cell • Maximum voltage (Vmaxp) at Pmax • Calculation of efficiency (%)
• Maximum current (Imaxp) at Pmax • Manual single point test
SOL 122
SOLAR CABLE
Solar Cable (100m roll) Code Colour Size mm2 Amps
• Rated Voltage: WIR SW101* Black 2.5mm2 25
600/1000VAC SW102* Black 4mm2 32
900/1500VDC SW103* Black 6mm2 41
SW104* Red 4mm2 32
• Stranded tin-plated copper insulated SW105* Red 6mm2 41
with XLPE under a PVC jacket
*Add cut length to code: /5m, /10m, /20m, /50m, /500m, /1000m
INSTALLATION TOOLS & ACCESSORIES
Wire Stripper Wire Stripper X-PRO 50mm Shears Maxi Grip Crimping Tool Solar Tool Kit
PARTEAEDWNADTROEDDT PARTEAEDWNADTROEDDT
MET
Code STRIP-7-SOLAR STRIP-SOLARMINI BM1325 BM1311 BM531 PV-BOX
Aluminium box with foam
An automatic stripper for • Stripping depth stop • Innovative new spring • Wire Shears • For barrel open
round cables used in PV • Compact wire loaded opening action • Bi-Component terminals 0.5-6mm² cushion for PV tools.
solar and electric fence stripper designed • For the easy stripping handle for greater • Possibility to change All tools in storage.
installation. Precise for the solar industry and cutting of cables cutting force the crimping force
adjustment allows easy • Suits 1.5-6mm2 • Especially designed • Non-slip serrated Solar Connector Spanner
removal of multiple cable blade for cutting of blades
insulation layers of solar • Side blade cutter aluminium and copper • Tempered stainless
cables from 1.5-6mm². cables up to a size of steel blade
50mm² • Belt clip holder
PV-STX
SOLAR PUMPING SYSTEMS
• The system dispenses with energy storage devices and stores water instead of electricity. It improves the reliability of the device and at the same time,
it lowers the construction and maintenance costs of the system dramatically.
• Excellent stability and 98% energy conversion ratio.
• Protection against lightning, dry running, blocking and overload.
Application
• Desert control Order PV Panels Separately
• Sea water desalinization
• Agricultural irrigation Inverter Only
• Daily water supply
• Forest irrigation
• Remote watering troughs for animals
• Waste water treatment
Code KW Description Head (m) Flow Water No. of PV Code Rated Output MPP
(m³/day) Panels Current Voltage
PS370-1 0.37KW Solar Pumping System 27 - 35m 10-7.5m³/day 20 x 40W PB400L 3A 280 - 350V
PS550-1 0.55KW Solar Pumping System 37 - 52m 10-7.5m³/day 20 x 60W PB750L 5A 280 - 350V
PS750-1 0.75KW Solar Pumping System 45 - 61m 10-7.5m³/day 20 x 80W PB1500L 7A 280 - 350V
PS1100-2 1.10KW Solar Pumping System 54 - 73m 10-7.5m³/day 20 x 120W PB2200L 11A 280 - 350V
PS1500-2 1.50KW Solar Pumping System 68 - 95m 10-7.5m³/day 10 x 270W PB3700H 9A 500 - 600V
PS2200-1 2.20KW Solar Pumping System 91 - 133m 10-7.5m³/day 22 x 170W PB5500H 13A 500 - 600V
PS3000-1 3.7KW Solar Pumping System 118 - 169m 15-10m³/day 28 x 170W
SOLAR PS4000-1 5.5KW Solar Pumping System 155 - 207m 15-10m³/day 36 x 180W
System incl Inverter, Pump + Cable 30m + Connections
Features
• Solar pumping inverter converts DC voltage from the solar array into AC voltage to drive the pump.
• With the function of MPPT (maximum power point tracking), it regulates the output frequency according to irradiation in real time to achieve the
max power.
Product Advantages
• To drive pumps equipped with 3-phase induction motors. • Adjustable speed range of pump based on the actual situation
• Optimized SPWM (Sinusoidal pulse width modulation). (available solar power) of the system.
• Various operation modes and MPPT algorithms are available. • Protection functions: lightning, over/low input voltage, over current and overload
• Option of water-level detection and control is available. protection, etc.
123 SOL
DC SUBMERSIBLE PUMPS
Features
• Floating impeller design prevents sand blockages
• Highly durable
• Can handle upthrust load
Application Accessories Incl. Order PV Panels Separately
• Domestic & Municipal • Liquid Level Sensor
water supply • Torch light
• Irrigation • Connecting cable
• Industrial & Mining • Control Box
• Ponds & Gardens • Water level Sensor
Code Voltage Power Max. Flow Rate Max. Head Pump Size Solar Panels Outlet
80W 3" 100W x 1 3/4"
3TSS-0.5-28-12/80 12VDC 200W 0.5m3/h 28m 3" 90W x 3 3/4"
3TSC-1.9-23-36/250 36VDC 400W 1.9m3/h 23m 3" 130W x 4 3/4"
3TSC-3.5-34-48/400 48VDC 400W 3.5m3/h 34m 3" 130W x 4 3/4"
3TSC-2-80-48/400 48VDC 500W 2m3/h 80m 4" 170W x 4 1"
4TSS-2.5-70-48/500 48VDC 1000W 2.5m3/h 70m 4" 100W x 14 1"
4TSS-2.5-140-110/1000 110VDC 500W 2.5m3/h 140m 4" 170W x 14 1¼"
4TSC-4-57-48/500 48VDC 1000W 4.0m3/h 57m 4" 100W x 14 2"
4TSC-12.5-44-110/1000 110VDC 1200W 12.5m3/h 44m 5" 100W x 16 1½"
5TSS-5-80-110/1200 110VDC 5m3/h 80m
DC SOLAR FOUNTAIN PUMPS
Accessories Application Area
Pump Controller, Brass Impeller, This product is mainly used for
Cable Connector, Water Level fountain pumps, circulation or
Sensor, Cable for Solar Panel, small irrigation applications.
Eco-Frie Solar Flash Light.
ndly
ndly TSQB Order PV Panels Separately
Pump Type SOLARVoltagePowerMax. Flow RateMax. HeadI/0 SizeRequired PV Panels
24VDC 120W 2m3/h 25m 1" x 1" 80W x 2
TSQB2.0-25-24/120 24VDC 120W 3.2m3/h 18m 1" x 1" 80W x 2
TSSGJ3.2-18-24/120 36VDC 210W 2.2m3/h 37m 1" x 1" 90W x 3
TSQB2.2-37-36/210
DC SOLAR POOL PUMPS
Accessories
Pump Controller, Brass Impeller, Cable
Connector, Water Level Sensor, Cable for
Solar Panel, Solar Flash Light.
Eco-Frie Application Area TSSP Order PV Panels Separately
This product is mainly used for
swimming pool pumping applications.
Pump Type Voltage Power Max. Flow Rate Max. Head I/0 Size Required PV Panels
48VDC 500W 16m3/h 15m 1.5" x 1.5" 170W x 4
TSSP16-15-48/500 72VDC 750W 18m3/h 12m 2" x 2" 80W x 14
TSSP18-12-72/750 110VDC 1200W 25m3/h 15m 2.5" x 2.5" 100W x 16
TSSP25-15-110/1200 110VDC 1500W 30m3/h 20m 3" x 3" 100W x 16
TSSP30-20-110/1500
PV PUMP SYSTEM CONTROLLER
MPPT and DSP control features provide a stable clean DC to the batteries extending battery life and system reliability.
For use with the above TAIFU Solar Pumping Systems. Select controller to match system voltage.
Code Description
TSPC-12-24V 12 - 24VDC Solar pump system controller
TSPC-36-48V 36 - 48VDC Solar pump system controller
TSPC-72-110V 72 - 110VDC Solar pump system controller
SOL 124
Perfect for SOLAR GEYSER
use as stand-alone
unit or as a prefeed Solcrafte Solar Hot Water Solutions
system for a geyser. Solcrafte is a solar collector with an integrated tank. It offers various benefits such as frost
protection, easy installation and aesthetic design. Quick installation saves you time and money.
Heating Element Solcrafte is the answer: connect it either directly to the water lines or pre-feed it into an existing
geyser. Standard packaging includes a mounting kit (either on-roof @ 0º or flat roof @ 45º), a
Twin Port valve and a Pressure Reducing valve.
Code SOL 90-* SOL 150-* SOL 200-*
Number of collectors 1 1 1
Collector area 1.1m2 1.8m2 2.4m2
Tank size in litres
90l 150l 200l
Size (L x W x H) 2184 x 510 x 212mm 2184 x 800 x 212mm 2184 x 1100 x 212mm
Max Temp/Pressure 100˚C/4 bar 100˚C/4 bar 100˚C/4 bar
*Mounting system 0°/45° Incl. Incl. Incl.
Accessories
Code Description
SOL-1279 Optional screw-in heating element (2kW)
Heating Element HEAT PUMPS
Using a small amount of energy, a heat pump simply transfers heat from one source to another in order to create
hot water for residential, commercial and industrial applications.
* Heat Pump Only Code SDAW3.5-220 SDAW4.6-220 SDAW6.7-220 SDAW11.2-380
Power Supply
Rated Heating Capacity 220V / 1Ph /50Hz 220V / 1Ph /50Hz 220V / 1Ph /50Hz 380V / 3Ph /50Hz
Rated Power Input 3.5KW 5KW 7.2KW 10.5KW
Refrigerant 0.9KW 1.79KW 2.55KW
Compressor Type R410A 1.28KW R410A R417A
Max Outlet Water Temp Rotary R410A Rotary Rotary
Noise 60°C Rotary 60°C 60°C
COP (Heating/Work Done) 52dbA 60°C 54dbA 55dbA
3.89W/W 53dbA 4.02W/W 4.12W/W
3.91W/W
SABS SOLAR LGow PEreYssuSre ER
High Pressure System - SABS Approved
Code Tank Length Tank Capacity Collector Collector Area (m2)
ASHP-1858-15 1680mm 15 Tubes 1.86
ASHP-1858-20 2160mm 150l 20 Tubes 2.49
200l
Collector Area (m2)
Low Pressure System - SABS Approved 1.67
1.88
High Pressure Code Tank Length Tank Capacity Collector
SL-NF1.8-16 16 Tubes All the prices include tank,
Low Pressure SL-NF1.8-18 1225mm 150l 18 Tubes heat pipe vacuum tubes,
SL6-C1301BX003 1446mm 200l frame, air vent valve,
Note: Order Mixing Valve Seperately magnesium rod, screws & nuts
Accessories for Low Pressure System and carton box only.
125
SOLAR Code Description
SL-NF16-TUBES
SL-NF18-TUBES Spare Glass Tube for 100l Low Pressure
SL-NF-FTANK Spare Glass Tube for 150l Low Pressure
SL6-C1301BX003 Spare filler tank for 100/150l Low Pressure
Mix/Tempering Valve
• Inner tank: SUS304-2B (Low Pressure), SUS316 (High Pressure)
• Working pressure: 0.6MPA (High Pressure), 0.1MPA (Low Pressure)
• Vacuum tube: 58*1800mm 2.2mm thickness with special coating to aid absorption
• Frame: Galvanized steel 1.5mm
• Insulation: 50mm of high density polyurethane foam - Heat preservation: 72hrs
• Hail resistance: 40mm
SOL
WIND GENERATORS
Deltatronic wind generators are the latest design in wind generating technology. Units are built for harsh environments
using aluminium and stainless steel. Wind speed, vibration and generator RPM are electronically analysed and
controlled. Fitted with an emergency electronic braking system. The high quality alternators fitted to the generators are
manufactured exclusively for Deltatronic by Ducati energia.
Code DTWIND-1500 DTWIND-3000
Maximum Power 1500W 3000W
Output Voltage 0-300VAC 0-300VAC
Aux. Voltage 12V x 2 (102Ah batteries) 12V x 4 (102Ah batteries)
Pure Sine Inverter Yes Yes
Charge Regulator Yes Yes
Start Speed 2.2m/sec (8km/h) 2m/sec (7.2km/h)
Run Speed 12.5m/sec (45km/h) 12.5m/sec (45km/h)
No. of Blades 3 3
Blade Dia 2.1m 3.1m
Temp Range -20˚C to +45˚C -20˚C to +45˚C
Wind Brake Yes Yes
* Kits Includes: All accessories except the 6m mounting pole.
Mounting pole specification available from our technical department.
Spare Parts
Code Description Code Description
6061T6 Aluminium blade for DTWIND-1500 DTKIT-2 Complete body assembly
6061T8 Aluminium blade for DTWIND-3000 DTALT Alternator (same for both models)
DTANE Anemometer, wind speed monitor DTINV-1500 1.5kW Inverter for DTWIND-1500
JACK05 DT Wind System controller DTINV-3000 3.0kW Inverter for DTWIND-3000
DTKIT-1 Ball bearings, slip ring assembly, rectifier, SY120102 12V 102Ah Battery
gas shock absorber
HYBRID WIND & SOLAR TURBINES
Q-Series are small all-weather wind turbines which produce 400-1000W. These units are small in size, easy to
install, low cost, high efficiency, and could be used in a variety of geographical climate conditions.
Kit Code Q400 Q600 Q1000
Rated Power (W) 400W 600W 1000W
Rated Voltage (VDC)
Rated Current (A) 24 24 48
Rotor Diameter (M) 16 25 41
Start-Up Wind Speed (m/s) 1.5 1.6 1.8
Rated Wind Speed (m/s) 2.5-4 2.5-4 2.5-4
Max. Wind Speed (m/s) 9.6 10.5 13
45 45 45
Wind Turbine Type Permanent magnet Permanent magnet Permanent magnet
synchronous generator synchronous generator synchronous generator
Yaw Mode Mechanical Mechanical Mechanical
Wind Turbine Lifespan 15-20yrs 15-20yrs 15-20yrs
Blade Material Carbon Fibre Reinforced Plastic
No. of Blades 3 3
Tower Height 6m 3 6m
Matched Inverter Type Sine Wave 6m Sine Wave
Sine Wave
Kit Includes: Sine Wave Inverter, Wind Turbine, Blades, Pole and Wind/Solar Hybrid Controller
Hybrid Charge Controller SOLAR
Code SPWS05A-24 SPWS06A-24 SPWS10A-24
500W 1000W
Wind Turbine Max Power (W) 24V 600W 48V
Rated Battery Voltage (V) 40A 24V 60A
Wind Turbine Max Input Current (A) 10A 40A 10A
PV Max Charge Current LCD 10A LCD
Display 28V LCD 56V
Output Voltage 28V
Output Current 0-25A (adj) 0-25A (adj) 0-50A (adj)
SOL 126
INTEGRA INTELLIGENT ENERGY EFFICIENT SOFT STARTERS
The Integra Solo is a smart energy saving soft starter that reduces energy consumption on single phase motors and compressors when
under low or no load conditions. Applications include: Refridgeration, Chillers, Industrial Sewing Machines, small Conveyors, Oven Fans.
Code - 1ph Rating Amp kW Rating @ 220V - 1ph Cooling Weight KG
SI-SOLO13 13A 2.2kW Natural 0.8
SI-SOLO40 40A 7.5kW Natural 1.55
• Ensure that your motor only consumes the energy it requires when off load • Switch motors automatically off when not needed
EnSeaDrvegivnyigce • Significantly reduce your energy bills • Protect motors from excess heat & vibration
• Energy Saving Applications: Plastic Injection Moulding Machines, Power Presses, Timber Saws, Aggregate Crushers, Granulators,
Hydraulics, Pump-Jack Oil Pumps, Cutting Machines, Textile Looms, Conveyors, Fly-wheel Applications and Sewing Machines.
Code Code Code Motor Motor kW Semi-Con- Chassis
220-480V 525-575V 690V ductor Size mm
- 3ph - 3ph - 3ph Rating 690V Cooling Fuses
208-690V 208-230V 380-480V 525-575V
SI-11/V220-480 - - 23A 5.5 11 15 22 H 315
SI-15/V220-480 SI-15/V575 SI-15/V690 30A
7.5 15 22 30 Natural N/A W 130
SI-22/V220-480 SI-22/V575 SI-22/V690 42A 11 22 30 37 D 120
SI-30/V220-480/F* SI-30/V575/F* SI-30/V690/F* 53A 15 30 37 45 H 385
SI-37/V220-480/F* SI-37/V575/F* SI-37/V690/F* 65A 22 37 45 75 Forced N/A W 130
SI-55/V220-480/F* SI-55/V575/F* SI-55/V690/F* 97A
30 55 75 90 D 215
SI-75/V220-480/F* SI-75/V575/F* SI-75/V690/F* 145A 45 75 110 150 H 448
SI-90/V220-480/F* SI-90/V575/F* SI-90/V690/F* 170A 55 90 132 155 Forced Fitted W 305
SI-110/V220-480/F* SI-110/V575/F* SI-110/V690/F* 205A 63 110 150 190 D 205
SI-132/V220-480/F* SI-132/V575/F* SI-132/V690/F* 255A 75 132 186 240
SI-150/V220-480/F* SI-150/V575/F* SI-150/V690/F* 290A 300 H 670
SI-186/V220-480/F* SI-186/V575/F* SI-186/V690/F* 340A 85 150 220 Forced Fitted W 380
SI-225/V220-480/F* SI-225/V575/F* SI-225/V690/F* 410A 110 186 260 320 D 225
132 225 315 400
SI-260/V220-480/F-UN SI-260/V575/F* SI-260/V690/F* 475A 150 260 375 450 H 750
SI-315/V220-480/F-UN SI-315/V575/F* SI-315/V690/F* 580A 186 315 450 550 Forced Fitted W 480
SI-375/V220-480/F-UN SI-375/V575/F* SI-375/V690/F* 670A 215 375 500 630 D 265
* Add 110 for 110V Fan & 220 for 220V Fan. UN = Universal 110/220V
COMPACT SOFT STARTERS
3-Phase 400V Soft Starter (Din Mount)
Code kW @ 400V Amp Size (H x W x D)
HPISE4006-C10 2.2kW 3 - 6A 149.5 x 47 x 113.8
HPISE4010-C10 4kW 7 - 10A 149.5 x 47 x 113.8
HPISE4016-C10 7.5kW 11 - 16A 149.5 x 47 x 113.8
HPISE4025-C10 11kW 17 - 25A 167.0 x 47 x 128.0
HPISE4030-C10 15kW 26 - 30A 167.0 x 47 x 128.0
HPISE4045-C10 22kW 31 - 45A 202.0 x 54 x 153.0
Application
Features • Top of Ramp aux
• Phase sequence/over temp alarm aux
• Pumps • Control Voltage 110-240VAC • Soft Start 1 - 20 sec
• Packaging Machinery • LED Indication • Soft Stop 0 - 20 sec
• Conveyors • 4 Starts per hour • Start V adj 5 - 50%
• Built-in bypass contacts
PUMP SPEEDDRIVE IP55
MOTOR CONTROL The most efficient system for adjusting a pump’s hydraulic performance to the
pressure and flow requirements of supplying is through the use of a variable speed
technology. The potential to SAVE UP TO 50% of energy from conventional methods.
Code I/O Voltage Max Current Dimensions (mm)
ESD-M2-1,5KW 1PH 230V / 3PH 230V 7 207 x 207 x 128
ESD-T3-4,0KW 3PH 400V / 3PH 400V 9 207 x 207 x 128
Accessories
Code Description
ESD-PT Pressure Transducer Output: 4 - 20mA
Specifications
ESD-PT • Simple set - up • Programmable constant flow
• 2x 4-20mA sensor inputs • Adjustable stop time
• Single or multiple pump control • Max no. of 4 units in series
127 EES
CSXI Series AUCOM SOFT STARTERS
Input Voltage: 3 Phase 200-575V EMX3 Series
• Compact Size
• Integrated Bypass Contactors Input Voltage: 3 Phase 380-690V
• Essential Motor Protection • Advanced Start & Stop Control Functions
• Simple to Use • Full Graphical LCD Display
• IP65 Remote Mountable Keypad (Optional)
• Extensive Motor Protections
Amp Code Dimensions (mm) Amp Code Dimensions (mm) Amp Code Dimensions (mm)
17A H xW x D H x WxD H x WxD
CSXI-007-61 203 x 98 x 165 17A EMX3-0023B-711 295 x 156 x 192 284A EMX3-0350B-711 440 x 424 x 298
30A CSXI-015-61 203 x 98 x 165 34A EMX3-0043B-711 295 x 156 x 192 355A EMX3-0425B-711 440 x 424 x 298
40A CSXI-022-61 203 x 98 x 165 46A EMX3-0050B-711 295 x 156 x 192 383A EMX3-0500B-711 620 x 430 x 296
49A CSXI-030-61 203 x 98 x 165 55A EMX3-0076B-711 295 x 156 x 223 425A EMX3-0580B-711 620 x 430 x 296
65A CSXI-037-61 215 x 145 x 193 95A EMX3-0105B-711 295 x 156 x 223 512A EMX3-0700B-711 620 x 430 x 296
73A CSXI-045-61 215 x 145 x 193 106A EMX3-0145B-711 438 x 282 x 250 606A EMX3-0820B-711 620 x 430 x 296
96A CSXI-055-61 215 x 145 x 193 121A EMX3-0170B-711 438 x 282 x 250 684A EMX3-0920B-711 620 x 430 x 296
120A CSXI-075-61 240 x 202 x 214 178A EMX3-0220B-711 438 x 282 x 250 796A EMX3-1000B-711 620 x 430 x 296
142A CSXI-090-61 240 x 202 x 214 201A EMX3-0255B-711 440 x 424 x 298
165A CSXI-110-61 240 x 202 x 214
Accessories
Code Description Code Description
995-04938-00 995-04803-00 995-04938-00 EMX3 Keypad PIM-MB-01 Modbus Interface
995-08133-00 EMX3 Keypad Mounting Kit (3m) PIM-PB-01 Profibus Interface
995-04803-00 EMX3 I/0 Expansion Card PIM-USB-01 USB Interface
995-04804-00 EMX3 RTD/Ground Fault PIM-MT-01 Modbus TCP Interface
Expansion Card PIM-PN-01 Profinet Interface
PIM 995-04804-00 PIM-EI-01 Ethernet IP Interface
MEDIUM VOLTAGE SOFT STARTERS
Features
• High Voltage isolated from user control using fibre optics
• Modular design allows for expansion
• Extended phase arms allow quick inspection and replacement
• Enclosed panels in IP54 and MVX IP4X
• Fully customisable protection
• Unit can be fully tested at Low Voltage 400V MOTOR CONTROL
• Run, protection and signalling simulations can be done without motor connected
• Constant current or current ramp start mode Code Description Dimensions (mm)
H x D xW
Optional Features MVS***-V02
• Fieldbus options- Modbus, Profibus and Devicenet MVS***-V03 3 x 2300 VAC (± 10%) 2322 x 1349 x 844
ModbusTCP, Profinet, Ethernet IP MVS***-V04
• Over voltage protection MVS***-V06 3 x 3300 VAC (± 10%) 2322 x 1349 x 844
• Control supply transformer MVS***-V07
• Line and Bypass contactors MVS***-V11 3 x 4160 VAC (± 10%) 2322 x 1349 x 844
• Earthing and isolation switches MVS***-V13
3 x 6600 VAC (± 10%) 2322 x 1337 x 1044
3 x 7200 VAC (± 10%) 2322 x 1337 x 1044
3 x 11000 VAC (± 10%) Enquire for dimensions
3 x 13800 VAC (± 10%) Enquire for dimensions
***Current Range 80A - 500A Please contact ACDC Dynamics for a
fully customisable Medium Voltage
Soft Starter Solution
EES 128
VACON AC VARIABLE SPEED DRIVES
A compact drive with all Vacon 10 Series - 1 x 230VAC Input; 3 x 230VAC Output
functionality built into a IP20; Air Cooled; EMC Class C2; No Brake Chopper
single unit. Quick to
install, easy to use and High Overload Ratings Dimensions (mm)
perfect for many OEM
Applications. Code Motor Power KW Continuous WxHxD
Current IH
VACON0010-1L-0002-2
VACON0010-1L-0003-2 0,37 2,4 66 x 160 x 99
VACON0010-1L-0004-2
VACON0010-1L-0005-2 0,55 2,8 66 x 160 x 99
VACON0010-1L-0007-2
VACON0010-1L-0009-2 0,75 3,7 90 x 195 x 102
1,1 4,8 90 x 195 x 102
1,5 7 90 x 195 x 102
2,2 9,6 100 x 255 x 109
Vacon 10 Series - 3 x 380VAC Input; 3 x 380VAC Output
IP20; Air Cooled; EMC Class C2; Brake Chopper from 1,1KW up
VACON0010-3L-0002-4 0,55 1,9 66 x 160 x 99
VACON0010-3L-0003-4 0,75 2,4 66 x 160 x 99
VACON0010-3L-0004-4 1,1 3,3 90 x 195 x 102
VACON0010-3L-0005-4 1,5 4,3 90 x 195 x 102
VACON0010-3L-0006-4 2,2 5,6 90 x 195 x 102
VACON0010-3L-0008-4 3,0 7,6 100 x 255 x 109
VACON0010-3L-0009-4 4,0 9 100 x 255 x 109
VACON0010-3L-0012-4 5,5 12 100 x 255 x 109
Vacon 20 offers Vacon 20 Series - 3 x 380VAC Input; 3 x 380VAC Output
outstanding performance IP20; Air Cooled; EMC Class C4; Brake Chopper
adaptablility and built-in
functionality. VACON0020-3L-0016-4 7,5 16 165 x 370 x 165
VACON0020-3L-0023-4 11 23 165 x 370 x 165
VACON0020-3L-0031-4 15 31 165 x 414 x 202
VACON0020-3L-0038-4 18,5 38 165 x 414 x 202
Vacon 100 Series - 3 x 380VAC Input; 3 x 380VAC Output
Vacon 100 bursts IP21; Wall-Mounted; EMC Class C2; Ethernet
with smart features
for a wide range of Code Code High Overload Ratings Dimensions
applications including VACON 100
those where energy General Purpose HD* VACON 100 FLOW Motor Continuous (mm)
efficiency and
productivity VACON0100-3L-0003-5 Pump & Fan Applications Power KW Current IH W x H x D
improvements result
in rapid return of VACON0100-3L-0003-5-FLOW 0,75 2,6 128 x 328 x 190
investments.
C/w Built-In Brake VACON0100-3L-0004-5 VACON0100-3L-0004-5-FLOW 1,1 3,4 128 x 328 x 190
Chopper.
VACON0100-3L-0005-5 VACON0100-3L-0005-5-FLOW 1,5 4,3 128 x 328 x 190
VACON0100-3L-0008-5 VACON0100-3L-0008-5-FLOW 2,2 5,6 128 x 328 x 190
VACON0100-3L-0009-5 VACON0100-3L-0009-5-FLOW 3 8 128 x 328 x 190
Vacon 100 VACON0100-3L-0012-5 VACON0100-3L-0012-5-FLOW 4 9,6 128 x 328 x 190
VACON0100-3L-0016-5 VACON0100-3L-0016-5-FLOW 5,5 12 144 x 419 x 214
VACON0100-3L-0023-5 VACON0100-3L-0023-5-FLOW 7,5 16 144 x 419 x 214
MOTOR CONTROL Intelligent pump & VACON0100-3L-0031-5 VACON0100-3L-0031-5-FLOW 11 23 144 x 419 x 214
fan control. Vacon
100 FLOW features VACON0100-3L-0038-5 VACON0100-3L-0038-5-FLOW 15 31 195 x 557 x 229
a real-time clock
that supports VACON0100-3L-0046-5 VACON0100-3L-0046-5-FLOW 18,5 38 195 x 557 x 229
calendar based
functions. VACON0100-3L-0061-5 VACON0100-3L-0061-5-FLOW 22 46 195 x 557 x 229
No Brake Chopper.
VACON0100-3L-0072-5 VACON0100-3L-0072-5-FLOW 30 61 237 x 660 x 259
VACON0100-3L-0087-5 VACON0100-3L-0087-5-FLOW 37 72 237 x 660 x 259
VACON0100-3L-0105-5 VACON0100-3L-0105-5-FLOW 45 87 237 x 660 x 259
VACON0100-3L-0140-5 VACON0100-3L-0140-5-FLOW 55 105 290 x 966 x 343
VACON0100-3L-0170-5 VACON0100-3L-0170-5-FLOW 75 140 290 x 966 x 343
Vacon 100 FLOW VACON0100-3L-0205-5 VACON0100-3L-0205-5-FLOW 90 170 290 x 966 x 343
*HD - Heavy Duty Applications
VACON0100-3L-0261-5 VACON0100-3L-0261-5-FLOW 110 205 480 x 1150 x 365
VACON0100-3L-0310-5 VACON0100-3L-0310-5-FLOW 132 261 480 x 1150 x 365
129 EES
VACON NXS & NXP AC VARIABLE SPEED DRIVES
Vacon NXS 525-690V
IP21 Air-Cooled Wall-Mounted, EMC Class H, Brake Chopper
OPT-A1 and OPT-A2 is standard with all NXS units. IP54 enclosure available on request.
High Overload Ratings Dimensions (mm)
Code Motor Power KW Continuous WxHxD
NXS00046A2H1SSSA1A2 Current IH
2,2 3,2 195 x 519 x 237
NXS00056A2H1SSSA1A2 3 4,5 195 x 519 x 237
NXS00076A2H1SSSA1A2 4 5,5 195 x 519 x 237
NXS00106A2H1SSSA1A2 5,5 7,5 195 x 519 x 237
NXS00136A2H1SSSA1A2 7,5 10 195 x 519 x 237
A robust, powerful standard AC drive with trip free NXS00186A2H1SSSA1A2 11 13,5 195 x 519 x 237
operation which is fit for use in heavy industrial or NXS00226A2H1SSSA1A2 15 18 195 x 519 x 237
mining applications. NXS00276A2H1SSSA1A2 18,5 22 195 x 519 x 237
NXS00346A2H1SSSA1A2 22 27 195 x 519 x 237
NXS00416A2H1SSSA1A2 30 34 237 x 591 x 257
NXS00526A2H1SSSA1A2 37,5 41 237 x 591 x 257
NXS00626A2H1SSSA1A2 45 52 291 x 758 x 344
NXS00806A2H1SSSA1A2 55 62 291 x 758 x 344
NXS01006A2H1SSSA1A2 75 80 291 x 758 x 344
NXS01256A2H1SSFA1A2 90 100 480 x 1150 x 362
NXS01446A2H1SSFA1A2 110 125 480 x 1150 x 362
NXS01706A2H1SSFA1A2 132 144 480 x 1150 x 362
NXS02086A2H1SSFA1A2 160 170 480 x 1150 x 362
Vacon NXS 380-500V
IP21 Air-Cooled Standalone, EMC Class H, No Brake Chopper. IP54 enclosure available on request.
High Overload Ratings Dimensions (mm)
Code Motor Power KW Continuous WxHxD
NXS03855A2L0SSAA1A2 Current IH
160 300 595 x 2020 x 602
NXS04605A2L0SSAA1A2 200 385 595 x 2020 x 602
NXS05205A2L0SSAA1A2 250 460 595 x 2020 x 602
NXS05905A2L0SSAA1A2 250 520 794 x 2020 x 602
NXS06505A2L0SSAA1A2 315 590 794 x 2020 x 602
NXS07305A2L0SSAA1A2 355 650 794 x 2020 x 602
Vacon NXS 525-690V MOTOR CONTROL
IP21 Air-Cooled Standalone, EMC Class L, No Brake Chopper. IP54 enclosure available on request.
NXS02616A2L0SSAA1A2 200 208 595 x 2020 x 602
NXS03256A2L0SSAA1A2 250 261 595 x 2020 x 602
NXS03856A2L0SSAA1A2 315 325 595 x 2020 x 602
NXS04166A2L0SSAA1A2 315 325 794 x 2020 x 602
NXS04606A2L0SSAA1A2 355 385 794 x 2020 x 602
NXS05026A2L0SSAA1A2 450 460 794 x 2020 x 602
A robust and fully enclosed standalone AC drive NXS05906A2L0SSAA1A2 500 502 794 x 2020 x 602
with IP21 protection which makes it perfect for
heavy use areas with limited space.
EES 130
VACON NXS & NXP OPTIONS
Installation Accessories
Display panels, Door installation sets, RS232 cables (Confirm selection with drives division prior to ordering)
DU/DT Filters & Sine Wave Filters Available For All VSD's
Code Description Code Description
PAN-A Alphanumeric display panel DRA-15B Door installation set for display panel, 15 m cable
PAN-A-A-MP Enhanced NXP alphanumeric panel DRA-02L Door installation set for display panel, 2 m cable
VACON-PAN-HMGR-MC02-HVAC Vacon 100 HVAC Graphical keypad DRA-04L Door installation set for display panel, 4 m cable
VACON-PAN-HMGR-MK01 Vacon 100 Graphical keypad RS232C-2M 2 m RS232 serial link cable, pin to pin
VACON-PAN-HMDR-MK01-NM Vacon 100 door mounting kit. RS232C-4M 4 m RS232 serial link cable, pin to pin
VACON-PAN-HMDR-MK01-3M Vacon 100 door mounting kit with 3m cable. RS232C-15M 15 m RS232 serial link cable, pin to pin
VACON-PAN-HMDR-MK01-6M Vacon 100 door mounting kit with 6m cable. RS232-1,5M 1,5 m RS232 PC cable
CAB-RJ45P-3M Vacon 100 RJ45 3m cable for door mounting kit SYS-1M Fiber optic cable (pair), 1 m
CAB-RJ45P-6M Vacon 100 RJ45 6m cable for door mounting kit SYS-2M Fiber optic cable (pair), 2 m
PAN-G-A-MP Enhanced NXP Full graphic panel SYS-4M Fiber optic cable (pair), 4 m
DRA-02B Door installation set for display panel, 2m SYS-10M Fiber optic cable (pair), 10 m
incl cable for NSX/NXP CAB-USB/RS485 PC cable for SW tools Vacon 100 HVAC, USB to RS-485, cable
DRA-04B Door installation set for display panel, 4m incl cable length 3 m
Expansion options for 100 / HVAC / FLOW / NXS / NXP (Confirm selection with drives division prior to ordering)
MOTOR CONTROL Code Description Code Description
OPT-A1 6DI, 1DO, 2AI(mA/V), 1AO(mA/V), +10Vref, OPT-B9-V 1 x RO, 5 x DI (42-240VAC)
+24V INT/EXT OPT-BF-V 1 x AO, 1 x DO, 1 x RO
OPT-A2 2RO(NO/NC) OPT-BH-V 3 x Temp sensor inputs (PT100, PT1000,
OPT-A3-V 1RO(NO/NC), 1RO(NO), Thermistor KTY84-130, KTY84-150, KTY84-131, NI1000)
OPT-A4-V 3DI(Encoder RS422, Out +5 V/+15 V) OPT-BJ-V Safe Torque Off/ATEX (Vacon 100/FLOW slot E)
OPT-A5-V 3DI(Encoder 10...24V, Out +15 V/+24 V) OPT-C2 Modbus RTU / N2 Interface
OPT-A7 Double encoder (Wide Range), 6D1, 2xDO OPT-C3-V Profibus DP Interface
OPT-A8 As OPT-A1, but analog I/O and +10Vref galv. OPT-C4-V LonWorks Interface
de-coupled as a group OPT-C5-V Profibus DP (D9 type connector) Interface
OPT-A9 As OPT-A1, but 2,5 mm² terminals, (not to be used OPT-C6 CANopen Interface
with OPT-AF-V board) OPT-C7-V DeviceNet Interface
OPT-AA 3DI, 1RO(NO/NC), 1DO OPT-C8 Modbus RTU / N2 (D9 type connector) Interface
OPT-AE Encoder board (Wide Range), 3DI(Encoder 10..24 V OPT-CI-V Modbus TCP/IP Interface
Out +15 V/+24 V) 2DO (encoder divider and direction) OPT-CJ-V BACnet MS/TP Interface
OPT-AF-V STO SIL2/PL"d" + ATEX approved thermistor. (Not to OPT-CG-V S2 Protocol Interface
be used with OPT-A9 Board) OPT-CP-V ProfiNet I/O Interface
OPT-AI I/O expander board for NXL, 3DI, 1RO (NO), OPT-CQ-V Ethernet/IP Interface
Thermistor OPT-D1 System Bus adapter (2x fiber optic cable)
OPT-AK-V SIN/COS encoder interface OPT-D2-V System Bus (1x fiber optic cable) & CAN-bus
OPT-AL-V 6DI (42…240VAC), 2AI, 2AO, 1DO (galv. decoupled)
OPT-AN-V 6DI galv. de-coupled as a group, 2AI and 2AO OPT-D3 RS232 adapter card (not galvanically decoupled)
(Programmable 0…20mA, 4…20mA, 0…10V, 2… OPT-D6-V CAN-Bus (galv. decoupled) Interface
OPT-B1-V 10V, -10…+10V) OPT-D7 Line voltage measurement board
OPT-B2-V 6DI/DO (programmable, DI or DO) OPT-E3-V Profibus DPV1 Interface
OPT-B4-V 1RO(NO/NC), 1RO(NO), Thermistor OPT-E5-V Profibus DPV1 (D9) Interface
OPT-B5-V 1AI(mA, isolated), 2AO(mA, isolated), +24V INT/EXT OPT-E6-V CANopen Interface
OPT-B8-V 3RO(NO) OPT-E7-V DeviceNet Interface
OPT-BB 3Pt100, +24V INT/EXT OPT-F1-V 3 x RO
OPT-BC ENDAT encoder card, 2xDO (RS422) OPT-F2-V 2 x RO + Thermistor
OPT-BE-V RESOLVER, 3x DO (Wide Range) OPT-F3-V 3 x RO
SSI and Endat Encoders OPT-F4-V 2 x RO + Thermistor
Abbreviations RO - Relay Output I/O - Input/Output MEDIUM VOLTAGE VSD'S
DI - Digital Input NO - Normally Open mA - Milli Amps
DO - Digital Output NC - Normally Closed V - Volts WATCH THIS SPACE!
AO - Analogue Output STO - Safe Torque Off VAC - Volts AC
AI - Analogue Input
131 EES
ELECTRIC MOTOR / PUMP PROTECTION RELAYS
Pump and Motor Protection / Phase Angle Relays Selection Guide
Specifications Code TE01* TE02* TE03*
Supply Voltage 230VAC ±20% Single phase 11 Pin Plug In • ••
400VAC or 525VAC ±20% 3phase Running dry- Under load
Power Consumption 2VA •••
blocked in/outlet
Calibration Manual or Automatic (Model dependant) Overcurrent Auto Auto
Dry Trip Level 10% of calibrated phase angle / current 2s delay Phase Failure / Reversal ••
Dry Restart Delay 15 minutes to 24 hours adjustable Over / Under voltage • •
•
Output Relay SPDT 250VAC/10A •
Voltage Trip Level 10% of calibrated voltage, 2 sec delay (TE02/TE03) Star/Delta or Soft Start •** •
Current Trip Level 20% of calibrated current, 1 sec delay (TE02/TE03) Locked Rotor •
TE01
TE02/TE03 Rapid Start Cycle 3 per 15 minutes maximum (TE03 only) Shunt Required •
LED Status Indication TE02/TE03 Rapid pump start protection
Green Amber Red Condition Cut-out over 12 starts/hour •
ON OFF OFF Normal Pumping LED Status Indication •
FLASH OFF OFF Dry-timing or phase failure/reversal Calibration Manual Auto Auto
OFF ON OFF Supply Voltage Low/High Tank Control (float switch) •
OFF FLASH OFF Rapid Cycle *Add to Code: 230 = 230VAC, 400 = 400VAC, 525 = 525VAC
OFF OFF ON Motor Overload or Phase Failure **TE01/S version only
ON ON ON TE02/3 Uncalibrated Accessories
FLASH FLASH FLASH TE02/3 Calibrating Code Description
OFF OFF OFF Unable to Calibrate TE01 SHUNT R Spare Red Shunt
Spare White Shunt
M1 TE01 SHUNT W
Current Transformer Selection Chart for TE Series
230VAC 400VAC
TE01 - PW155 PW205 PW255 - - PW205 PW305 PW405 PW405 DS-505 DS-755 DS-1005 DS-1005 DS-1055
TE02/03 - PW155 PW205 PW255 - PW155 PW205 PW305 PW405 PW405 DS-505 DS-755 DS-1005 DS-1005 DS-1055
HP 0.36-1.1 1.5 2 3 0.5-1.5 2-7.5 10 15 20 25 30 40 50 60 75
Kw 0.25-0.75 1.1 1.5 2.2 0.37-1.1 1.5-5.5 7.5 11 15 18.5 22 30 37 45 55
Shunt White Red White
ELECTRONIC MOTOR & OVERLOAD PROTECTION RELAYS
Phase Angle Motor Protection Relays
Mainly used for borehole protection with liquid level control tank filling. DIN mount.
Code Description Max. Current Continuous
MP820/230VAC-SP Single phase motor protection relay up to 1.1kW * 15A
MP825/230VAC-SP Single phase motor protection relay above 1.1kW * 15A
MP830/230VAC-SP Three phase motor protection relay up to 3.7kW * 12A
MP830/400VAC-SP Three phase motor protection relay up to 3.7kW * 12A
MP830/525VAC-SP Three phase motor protection relay up to 3.7kW * 12A
MP835/230VAC-SP Three phase motor protection relay up to 3.7kW * 12A
MP835/400VAC-SP Three phase motor protection relay up to 3.7kW * 12A
Single Phase Features * For higher load current use 5 Amp CT to achieve accurate calibration MOTOR CONTROL
Three Phase Features
MP820: • Direct in-line current sensing of motor, up to 1.1kW RHE MP830: • Direct in-line current sensing of motor, up to 3.7kW
• Auto calibration of over/under current and voltage • Auto calibration of over/under current and voltage
• Start up delay (3 seconds standard) • Start up delay (3 seconds standard)
• Adjustable reset time 15 mins to 24 hrs • Adjustable reset time 15 mins to 24 hrs
• Latching on overload conditions • Latching of over load conditions
• Liquid Level Control (50kΩ) • Liquid Level Control (50kΩ)
• Reset Lock out, Max 3 reset attempts in 15 minutes • Reset Lock out, Max 3 reset attempts in 15 minutes
MP825: As for MP820 plus • Phase sequence/phase failure detection
• Latching of over and under load conditions MP835: As for MP830 plus
• Manual adjustment of under load sensitivity • Latching of over and under load conditions
(after auto calibration) • Manual adjustment of under load sensitivity
(after auto calibration)
132
ELECTRIC MOTOR / PUMP PROTECTION RELAYS
Motorscope Pump Protection Relay
Protection of AC motors and their driven systems can be achieved by limiting the maximum
and minimum consumed motor power. The power consumption (kW) formula is:
P = √³ x V x I x CosØ. All Motorscopes mount directly onto DIN RAIL.
Features UNO TRIO SUPRA B110*
Description 1 Phase 3 Phase 3 Phase Industrial
230V 400V 400V 110/230
0.37-2.2kW 0.37-5.6kW 5.6-37kW 400/525
1000V TRIO B110
Running dry, under load blocked inlet/outlet • • •• LED Status Indication
Overcurrent •
Phase failure/phase reversal • • • • Green Amber Red Condition
Phase imbalance •
Over / Under voltage ― • • • ON OFF OFF Normal Running
―
• • • OFF FLASH FLASH Voltage Fault
• • OFF FLASH OFF Underload/ Restart
Star Delta and Soft start connection ― • • • OFF FLASH ON Current Fault
Tank control (float/pressure switch)5VDC • • • • FLASH FLASH OFF Start Delay
Locked rotor • • • • OFF ON ON Phase Rotation Fault
CT250/1 Supplied with unit •―• • OFF OFF ON Overload
Built-In Optimizer
― ― • ― OFF ON OFF Underload
B110: * To be used where the supply voltage and the motor voltage differ, e.g. Motor is 525V and the control is 110V. Note: Specify control voltage when ordering.
Accessories Description
Code
DOWNLOADER DOWNLOADER Comprises of PC software and hardware to download data from Motorscope to PC.
It can also interface between Motorscope and PC for data logging and real time
graphic display of parameters. Supplied with cables.
OPTIMIZER Has 2 funtions: 1) For commissioning, it can modify a number of factory default
settings to optomise the Motorscope for each application, as well as viewing every
operational parameter. 2) For maintenance, it can download the last 30 events from
the Motorscope and in turn download data to a PC via DOWNLOADER.
AGEM Advanced GSM Enabled Modem which acts as a gateway between Motorscope relay
and the internet. Data is transfered from the device to an online database. The data
OPTIMIZER AGEM stored on the database can then be accessed through our browser based
ROCS (Remote Online Control System)
Electronic Overload Protection Relays
Code Current Range OL PL LR PU PR STL UL ALT GF Trip Disp Control
Type Type Voltage
CSMPA-60-T CSMPA-60-T 6A 0.5-6A • • - - - - - - - D LED 110/220
CSMPA-60-T 60A 5-60A • • - - - - - - - D LED 110/220
MOTOR CONTROL CSMPA-22-3S-5A0 0.3-1.5A* • • - • - • - - - I LED 110-260
CSMPA-22-3S5A 1-5A • • - • - • - - - I LED 110-260
CSMPA-40R 1-SA 0.3-1.5A • • - • • • - - - I LED 110-260
CSMPA-40R 5A 1-5A • • - • • • - - - I LED 110-260
CSMPM-06-SZ 0.5-6A • • • • • • • • • I + D LED 110/220
CSMPM-60-SZ 5-60A • • • • • • • • • I + D LED 110/220
Key : OL: over current PL: Phase Loss LR: Locked Rotor PU: Phase Unbalance PR: Phase Reverse
STL: Stalling UL: Under Current ALT: Alert (60-110%) GF: Ground Fault I: Inverse Time
D: Definite Time • : Available - : not available LED: Red & Green SSD: Seven Segment Display
CSMPA-40 Accessories Ground Fault Core Balance Transformer
CSMPM-06-SZ Code Description Code Hole Ø
CSMPM - 1.5M 1.5m ext cable for CSMPM - 06/60-S/ S1/SZ Z-CT D30 30mm
133
CSMPM - 4M 4m ext cable for CSMPM - 06/60-S/S1/SZ Z-CT D50 50mm
*NOTES: CSMPA22 - models with current range 1 - 5A can be used up to Z-CT D65 65mm
600A with suitable ratios CTs having 5A secondary, class 1 accuracy. Z-CT D80 80mm
EMP
ELECTRONIC MOTOR PROTECTION RELAYS
LA-Series Code Code
Standard with Battery(1)
Current
Range
1-10A LA-010 LA-010N
5-50A LA-050 LA-050N
10-100A LA-100 LA-100N
25-250A LA-250 LA-250N
(1)Required to maintain LED status if within cubicle with electrical interlock
Features - See chart on pg 135 for protection • Integrated current transformers
• O verload protection cyclic and s ustained • 1NO + 1NC 6A@250VAC
• 110/220VAC control supply
based on a 15 second cold curve
K-Series
KA- Current Code Code Code
KB- Range KA KB KC
KC-
MA-250-PM 0.1-1A KA-001 KB-001 KC-001
MA-RDU-1 0.5-5A KA-005 KB-005 KC-005
MA-RDU216
1-10A KA-010 KB-010 KC-010
2.5-25A KA-025 KB-025 KC-025
5-50A Use ‘-05’ with 3 x 50:5 CL1 2.5VA CTs
10-100A Use ‘-05’ with 3 x 100:5 CL1 2.5VA CTs
20-200A Use ‘-05’ with 3 x 200:5 CL1 2.5VA CTs
Features See chart on pg 135 for protection
• O verload protection cyclic and s ustained based on a 15 second cold thermal curve
• K A is powered from the 3ph 400V or 525V mains supply
• K B & KC is suitable for 110V/220VAC c ontrol only
• 1NO + 1NC 6A@250VAC
For CTs see page 228
MA-Series
Description Current Range Code
MA-005-*
Relay Without fieldbus interface 0.5-5A MA-010-*
MA-050-*
1-10A MA-100-*
MA-250-*
5-50A
* . . . - PM
10-100A * . . . - MM
* . . . - CM
25-250A MA-CAB1
MA-CD
For larger currents, use MA-005 with 3 x 5A CL1 CTs MA-RDU-1
Profibus comms replace * with MA-RDU216
MA-SD
Modbus comms replace * with
Canbus comms replace * with
Laptop Cable 1m
CD Front End Software MOTOR CONTROL
Door mount fault indicator c/w 1.5m cable
Door mountable MMI programming & interface unit c/w 1m cable
Security Dongle for MA-RDU216
Features See chart for “full house” protection info.
• O verload protection cyclic and s ustained with user • 5 x programmable digital inputs
adjustable thermal curves 5 to 35 seconds • 4 x 1C/O relay outputs 5A@220VAC
• F ield bus interfaces • 110V/220VAC control supply
• S oftware programmable LV protection for process
control
To set up or alter parameters, either use laptop with software (free) and cable, or
MA-RDU216 (supplied with 1.5m cable and security dongle)
EMP 134
ELECTRONIC MOTOR PROTECTION RELAYS
KD-Series - Supply Volts 110/230VAC
KD- Current Code Code CT’s Required
Range KD KE
KE-* with Internal
profibus 0.5-5A KD-005 KE-005 Internal
BBRTU Internal
module 1-10A KD-010 KE-010 Internal
100:5 Class 1 2.5VA
2.5-25A KD-025 KE-025 200:5 Class 1 2.5VA
400:5 Class 1 2.5VA
5-50A KD-050 KE-050
10-100A KD-100 KE-100
25-200A KD-200 KE-200
40-400A KD-400 KE-400
Note: KE-Relay cannot be programmed via front panel
Accessories
Code Description
KD-FLED KD-FLED Door mount indicator with Reset,Test and last fault indication. Provides IR
link to MMI or Laptop
KD-MMI420-EP KD-RDU420 KD-RDU420 Door mount Paramatization unit to set KD-KE parameters and display
values and faults. Provides IR link to MMI or Laptop.
KD-MMI420-EP To set KD-KE parameters, upload events, upload fault records, display
actual values and faults, connects via IRDA to relay
FPR0768 KD-KE profibus BBRTU module for profibus communication
CAB0100 RJ11-RJ11: Cable for connecting KD-FLED/KD-RDU420 to relay
CAB0101 RJ11-RS232: Cable for connection between relay and computer
CAB0016 USB to serial converter
FPR0202 RJ11-IRDA: Infrared eye for relay
FPR0205 RS232-IRDA: Infrared eye for computer
Features Protection Features
• Stores 2000 events and 60 faults with time and • Overload (both cyclic and sustained overload) • Phase rotation/over or under voltage
date stamping • Locked rotor by vectorial stall • Short circuit protection trip threshold power
• Running stall/jam
• Thermal curves selectable • Single phasing/unbalance factor dependant
• Profibus communication • Over/Under frequency protection • Starts per hour with selectable 1-3
• Earth leakage with harmonics filtering ideally • Insulation failure prestart lock-out
• Undercurrent/load loss/cavitation consecutive start attempts
suited for V.S.D. and large D.O.L applications • Under power (CosØ measurement)
• KE-Relay does power measurement, real and
apparent, in real time or consumption over time
Protection Features for Newelec Relays
LA KB KA KC MA* KD/KE LA KB KA KC MA* KD/KE
Max. current (w/o ext. CTs) 250A 25A 25A 25A 250A 50A Max. current (w/o ext. CTs) 250A 25A 25A 25A 250A 50A
Thermal memory ✔ ✔ ✔ ✔ ✔ ✔ Under voltage ✔ ✔ ✔ ✔
Locked rotor (at start) ✔ ✔ ✔ ✔ ✔ ✔ Voltage phase symmetry ✔ ✔ ✔ ✔
MOTOR CONTROL Jam (from running) ✔ ✔ ✔ LED trip indication ✔ ✔ ✔ ✔ ✔ ✔
Unbalanced load ✔ ✔ ✔ ✔ ✔ ✔ Door mount control option ✔ ✔
Phase loss ✔ ✔ ✔ ✔ ✔ ✔ MCCB fail - upstream tripping ✔
User select O/L auto reset ✔ ✔ ✔(1) ✔(1) ✔(1) MCCB/Contactor co-ordination ✔
Under current ✔ ✔ ✔ ✔ ✔ Earth leakage* (core incl. up to 250A) ✔ ✔
Restart timer ✔ ✔ ✔ Protocol option ✔
Restart contact ✔ ✔ ✔ 3 x PTC100 inputs ✔
Phase rotation ✔ ✔ ✔ ✔ Totalised running hours ✔
Over voltage ✔ ✔ ✔ ✔ Last 4 faults memory ✔
* For MA, CB CT is internal up to 250A. For over 250A use external core balance CT, see page 136. (1) 3 Starts per hour limit in auto mode.
135 EMP
ELECTRONIC MOTOR PROTECTION RELAYS
Comprehensive Motor Protection & Control Relay - Size: 99(H) x 45(W) x 113(D)mm
Code FPR0400
Supply Voltage 110 - 230VAC/DC
Power Usage 2.5W
Relay Outputs 4 x C/O (5A@220VAC)
3 Phase Current Measurement 1 - 400A
Voltage Range 110 - 1100V (Via CT Module Block)
Earth Leakage 30mA - 3A
Insulation Resistance Measurement 1-99kΩ
Real Time Clock 24 Hours
Battery Back-up for Clock 5 Days
• Fully configurable with the aid of free software or Man Machine Interface (MMI)
• Two types of Date/Time based records are stored in the onboard database store:
A. Fault Records (last 35 faults)
B. Event records (1400 events)
• Event records can be downloaded for further analysis
• All settings can be password protected
• A spectrum analyser for analysis of power quality and harmonics (up to 9th)
• Supported Comms Protocols: Profibus, Modbus, Canbus
Protection Features Automation Features Management Features
LED Indication LED Fault • Thermal Overload • Timers • Power Factor Measurement
of Input/Output State Indication • Locked Rotor • Real Time Clock • Power Consumption
• Running Stall-Jam • Start Control Logic
• Vectorial Start - Start Stall • 7 Field Inputs Measurement
• Unbalanced Current • Motor Parameter Calculator • 35 Last Fault Records
• Single Phasing • 4 Programmable Outputs • Statistical Data
• Underload - Dry Run • 3 Phase Recorder • 1400 Event Records
• Earth Fault - 30mA-3A • Multiple Comms Protocols
• Short Circuit
IRDA & USB Configurable Memory • Starts per Hour Limitation
Communication & Module on a T-Bus • Over/Under Voltage
Profibus address (option) allows easy • Phase Rotation
replacement & setup. • Over/Under Frequency
indication. • Insulation Lock-Out
Accessories
FPR0412 FPR0413 FPR0414
FPR0401/2 FPR0407 Code Description MOTOR CONTROL
BTX0005
FPR0420 FPR0407 External settings Memory Module for easy maintenance
FPR0404/5/6 FPR0409 FPR0420 Insulation Lock Out - Monitors resistance of static motor prevents start up if below 20kΩ
FPR0412 Expansion I/O, 8 In/4 Out (programmable relays)
FPR0413 RTD expansion module - 4 inputs which can be NTC, PTC, PT100 or PT1000
FPR0414 4/20mA module - 2 x input loops and 2 x output loops
FPR0404 CT Module Block 0.5 - 5A / 110 - 550VAC Volt Converter
FPR0405 CT Module Block 2.5 - 25A / 110 - 550VAC Volt Converter
FPR0406 CT Module Block 5 - 50A / 110 - 550VAC Volt Converter
FPR0402 CT Module Block 10 - 100A / 110 - 550VAC Volt Converter
FPR0401 CT Module Block 30 - 300A / 110 - 550VAC Volt Converter
FPR0208 Volt Converter - 1100V to 550V
FPR0408 CT Module to Relay Cable 1m
FPR0409 CT Module to Relay Cable 500mm
FPR0410 CT Module to Relay Cable 300mm
FPR0411 CT Module to Relay Cable 100mm
BTX0004 Core Balance CT 43mm
BTX0001 Core Balance CT 60mm
BTX0002 Core Balance CT 100mm
EMP 136
BOREHOLE PUMP CONTROLS
DOL Borehole Pump Control Panels with TE03 Pump Protection Relay
Protection Features: Dry run, locked rotor, overload, phase failure/reverse/imbalance,over/under
voltage, LED Status indication through window. Auto calibration for ease of commissioning.
General Features: Supplied with an Isolator, Contactor or Soft Starter, CT (where required),
Lightning Arrestors, TE03 protection relay, "Power On" and "Pump Run" LED indication lights.
Control Options: Standard: Hand / Off / Auto Selector Switch / Float Switch
LL: Hand / Off / Auto Selector Switch / Liquid Level Relay
U: Hand / Off / Auto Selector / 24-hour Timer
For optional extras, see below.
Pump Polycarbonate Enclosure IP56 Metal Enclosure IP65
kW Float Switch* With Liquid Level* With Time Switch Float Switch* With Liquid Level* With Time Switch
Single Phase 230VAC DOL
0.75kW B00S/IS/P U B00S/IS/LL/P U B00S/IS/U/P U B00S/IS/S U B00S/IS/LL/S U B00S/IS/U/S U
1.1kW B09S/IS/P U B09S/IS/LL/P U B09S/IS/U/P U B09S/IS/S U B09S/IS/LL/S U B09S/IS/U/S U
1.5kW B12S/IS/P U B12S/IS/LL/P U B12S/IS/U/P U B12S/IS/S U B12S/IS/LL/S U B12S/IS/U/S U
2.2kW B18S/IS/P U B18S/IS/LL/P U B18S/IS/U/P U B18S/IS/S U B18S/IS/LL/S U B18S/IS/U/S U
Three Phase 400VAC DOL B09T/IS/LL/P N B09T/IS/U/P N
B12T/IS/LL/P N B12T/IS/U/P N
4kW B09T/IS/P N B18T/IS/LL/P N B18T/IS/U/P N B09T/IS/S N B09T/IS/LL/S N B09T/IS/U/S N
B25T/IS/LL/P N B25T/IS/U/P N B12T/IS/S N B12T/IS/LL/S N B12T/IS/U/S N
5.5kW B12T/IS/P N B32T/IS/LL/P N B32T/IS/U/P N B18T/IS/S N B18T/IS/LL/S N B18T/IS/U/S N
B40T/IS/LL/P N B40T/IS/U/P N B25T/IS/S N B25T/IS/LL/S N B25T/IS/U/S N
7.5kW B18T/IS/P N B50T/IS/LL/P N B50T/IS/U/P N B32T/IS/S N B32T/IS/LL/S N B32T/IS/U/S N
B65T/IS/LL/P N B65T/IS/U/P N B40T/IS/S N B40T/IS/LL/S N B40T/IS/U/S N
11kW B25T/IS/P N B50T/IS/S N B50T/IS/LL/S N B50T/IS/U/S N
BS05T/IS/LL/P N BS05T/IS/U/P N B65T/IS/S N B65T/IS/LL/S N B65T/IS/U/S N
15kW B32T/IS/P N BS07T/IS/LL/P N BS07T/IS/U/P N
BS11T/IS/LL/P N BS11T/IS/U/P N
18.5kW B40T/IS/P N BS15T/IS/LL/P N BS15T/IS/U/P N
BS18T/IS/LL/P N BS18T/IS/U/P N
22kW B50T/IS/P N BS22T/IS/LL/P N BS22T/IS/U/P N
BS30T/IS/LL/P N BS30T/IS/U/P N
30kW B65T/IS/P N
Three Phase 400VAC Soft Start
5.5kW BS05T/IS/P N BS05T/IS/S N BS05T/IS/LL/S N BS05T/IS/U/S N
7.5kW BS07T/IS/P N BS07T/IS/S N BS07T/IS/LL/S N BS07T/IS/U/S N
11kW BS11T/IS/P N BS11T/IS/S N BS11T/IS/LL/S N BS11T/IS/U/S N
15kW BS15T/IS/P N BS15T/IS/S N BS15T/IS/LL/S N BS15T/IS/U/S N
18.5kW BS18T/IS/P N BS18T/IS/S N BS18T/IS/LL/S N BS18T/IS/U/S N
22kW BS22T/IS/P N BS22T/IS/S N BS22T/IS/LL/S N BS22T/IS/U/S N
30kW BS30T/IS/P N BS30T/IS/S N BS30T/IS/LL/S N BS30T/IS/U/S N
Optional Extras for Borehole Pump Controls *Order float switch or probes separately. See page 47 - 48.
Note: When requesting a price or when ordering a starter with optional extra, please
Code Description order optional extra as a separate line. Order example: 1) Borehole pump control
3 phase 5.5KW with isolator and liquid level control in a steel enclosure with running
EFS01 Ammeter Selector Switch up to 18.5kW hour meter as optional extra.
EFS03 Voltmeter 72 x 72, c/w Fuses - IP42 Item 1: B12T/IS/LL/S N Item 2: EFS05
EFS04 Voltmeter Selector Switch
EFS05 Running Hour Meter 48 x 48 Wireless solutions available including GSM. Contact our Panel Workshop
EFS19 Ammeter 72 x 72 - IP42
V1N-S Vigilec Pump Control Panels - IP56
Single and multi-pump dual voltage DOL control panels offering great control & protection features in one compact product.
Ratings: 12A max per motor. 1-ph: 230V 0.37-1.5kW; 3-ph: 400V 0.55-5.5kW. With front indication in poly enclosure.
Control Circuits: Probes 24VAC; Pressure Switches 12VAC.
Remote control provision wired (standard) or wireless (optional extra).
MOTOR CONTROL
1 ProbeApplicationControlProtection
2 Probe
Code Pump
Pressure SwQty
FloatsV2PType
Multi-Control
Alt Duty Cycle
Alarm Contact1
Isolator Hand
Lighting
Over Voltage
Phase Failure
Cable Break
Anti-Seize2
Dry Run3
Overload
Underload
V1N Borehole 1 •• • •• • • ••• • •••
V2P Booster 2 •• •••• • • •• ••
V3P V3P Booster 3 •• ••• • ••
V2B Sump4 2 • ••• •• ••
137
1 - Excess Start Frequency 2 - 1 Sec run per 23hrs when not in use 3 - 15 min Restart Time 4 - Drainage or sewerage
CO2
BOREHOLE PUMP CONTROLS
Economy Borehole Control Panel IP43 - Size: 275 x 300 x 150mm
Weatherproof steel enclosed control panels with 3 conduit entries, On-off switch, Pump protection relay
with provision for float switch, CT where required, Incoming isolator, Surge protection & contactor.
For features of the different protection relays, see pg 132-133.
Motor 230V FLC UNO TE03 TE03 +
Ammeter
≤ 0.75kW ≤ 6A BEUN1-015 BETE1-007 BETE1A-007
1.1kW 8.8A BEUN1-015 BETE1-011 BETE1A-011
1.5kW 11.8A BEUN1-015 BETE1-015 BETE1A-015
2.2kW 17A BEUN1-022 BETE1-022 BETE1A-022
Motor FLC TRIO SUPRA TE03 TE03 +
400V Ammeter
BETE3A-040
≤ 4.0kW 9A BETR3-055 - BETE3-040 BETE3A-055
BETE3A-075
BETR3-055 ≤ 5.5kW 13.2A BETR3-055 - BETE3-055
7.5kW 17.8A - BESU3-075 BETE3-075
DOL Borehole Pump Control Panel with Motorscope Relay IP65
Fitted in IP65 steel or fireglass enclosure with Door interlocked isolator, Surge protection, Contactor,
Motorscope relay with protection fuses and CT. Door fitted with "power on" and "run" LED pilot-lights,
on-off selector switch and viewing window for Motorscope LED array. Provision for remote float swtich.
Code Pump kW Voltage Enclosure Type Size (H x W x D)
TRIO-SP5.6 0.37 - 5.6kW 400V Steel 450 x 300 x 220mm
TRIO-SP5.6 TRIO-SP5.6/F 0.37 - 5.6kW 400V Fibre Glass 350 x 250 x 160mm
SUPRA-SP11 7.5 - 11kW 400V Steel 450 x 300 x 220mm
SUPRA-SP22 15 - 22kW 400V Steel 450 x 300 x 220mm
TRIO-SP5.6/F SUPRA-SP37 30 - 37kW 400V Steel 450 x 300 x 220mm
Compact Borehole DOL Starter with TE03 Protection
With Contactor for motors up to 5.6kW @ 400V and 2.2kW @ 230V. Protection features: Dry run,
locked rotor, overload, phase failure/reversal/imbalance, over/under voltage, auto calibration for easy
commissioning and LED array for full status indication. Housed in compact IP56 polycarbonate
enclosure with glands and on/off switch. Connection for float switch.
Code Description Size (H x W x D)
TE05M Pump controller for 230V single phase motors up to 0.75kW 200 x 140 x 80mm
TE05M-1 Pump controller for 230V single phase motors 1.1 to 2.2kW 200 x 140 x 80mm
TE05Q Pump controller for 400V three phase motors up to 4kW 200 x 140 x 80mm
TE05 TE05Q-1 Pump controller for 400V three phase motors 5.6kW 200 x 140 x 80mm
Compact Borehole DOL Starter with Motorscope Protection
TRIO PANEL With Contactor for motors up to 5.6kW @ 400V. Protection features: Event memory, dry run, locked
rotor, overload, phase failure/reversal/imbalance, over/under voltage, auto calibration for easy
commissioning and LED array for full status indication. Housed in compact IP56 polycarbonate MOTOR CONTROL
enclosure. Connection for float switch.
Code Description Size (H x W x D)
TRIO PANEL Pump controller for 400V 3Ph Motors 0.37 - 5.6kW 300 x 220 x 180mm
COMPRESSOR STARTERS
Star-Delta starters with on-off selector switch and provision for pressure switch connection.
415V coils fitted. IP56
Code Motor kW @ 400V Size (H x W x D)
AS7.5 7.5kW 240 x 190 x 160mm
AS11 11kW 300 x 220 x 180mm
AS15 AS15 15kW 300 x 220 x 180mm
CO2 138
Economy DOL Starters - 3ph DOL STARTERS
Economy DOL Starters - 1ph
For 230V Single
Phase motors,
Coil fitted,
U 240V
(Customer to fit T1-L2 Link)
BE1-T40 (Steel)
kW AC3 Overload DOL Starter IP65 DOL Starters with DOL Starters with kW AC3 Overload
0.37kW Range isolator IP65 ammeter IP54 Current DOL Starter IP65
0.55kW Range Fitted
0.63-1.0A
LE1-D123N305 ILE1-D123N305 ALE1-D123N305 0.37kW 2-8-4.2A LE1-D123U308
1.0 -1.6A
LE1-D123N306 ILE1-D123N306 ALE1-D123N306 0.55kW 4-6A LE1-D123U310
0.75kW 1.6-2.5A LE1-D123N307 ILE1-D123N307 ALE1-D123N307 0.75kW 4-6A LE1-D123U310
1.1kW 1.6-2.5A LE1-D123N307 ILE1-D123N307 ALE1-D123N307 1.1kW 7-10A LE1-D123U314
1.5kW 2.5-4.0A LE1-D123N308 ILE1-D123N308 ALE1-D123N308 1.5kW 9-13A LE1-D123U316
2.2kW 4-6A LE1-D123N310 ILE1-D123N310 ALE1-D123N310 2.2kW 12-18A LE1-D183U321
3kW 5.5-8A LE1-D123N312 ILE1-D123N312 ALE1-D123N312
4kW 7-10A LE1-D123N314 ILE1-D123N314 ALE1-D123N314 New wide range coil voltages
5.5kW 9-13A LE1-D123N316 ILE1-D123N316 ALE1-D123N316 U 240V (170-280V)
7.5kW 12-18A LE1-D183N321 ILE1-D183N321 ALE1-D183N321
11kW 17-25A LE1-D253N322 ILE1-D253N322 ALE1-D253N322
15kW 23-32A LE1-D323N353 ILE1-D323N353 ALE1-D323N353 N 415V (352-465V)
15kW 23-32A BE1-T3235N353 - -
18.5kW 30-40A BE1-T4035N355 - - SF 550V (465-605V)
22kW 37-50A BE1-T5036N357 - -
30kW 48-65A BE1-T6535N361 - - Ideal for agricultural applications
37kW LE1 c/w plastic enclosure
45kW BE1 c/w metal enclosure
139 63-80A BE1-T8035N363 - -
80-93A BE1-T9535N343 - -
MOTOR CONTROL DOL Starters without Overload Accessories
Code
Code Description Description
LE1-D12 Empty enclosure c/w push buttons
LE1-D123* 5.5kW LE1-D25 Up to 7.5kW
LE1-D32 For 11kW
LE1-D183* 7.5kW BE1-T40 For 15kW
LA9-D09906 For 18-24kW (Steel)
LE1-D253* 11kW LE1-DSBG Start switch - Up to 7.5kW
LE1-DSBR Green Start Button
LE1-D323* 15kW BE1-T40 (Steel) LE1-D32 Red Stop Button
Coil voltage: 275(L) x 160(W) 195(L) x 100(W) x
*SF 550V (465-605V)
*U 240V (170-280V) x 145(D) 145(D)
*N 415V (352-465V)
Size: 195(L) x 100(W) x 145(D)
CO1
DOL STARTERS & DOL REVERSING STARTERS
DOL Starters
Optional extras: Isolator, Ammeter and choice of IP65 Steel Enclosure or IP56 Polycarbonate Enclosure.
Starters can be customised by adding items from the Optional Extras table below.
Code Motor Motor Overload With With Enclo- Coil Steel Encl. Poly Encl.
kW @ kW @ Range Isolator Am- sure Voltage Size* Size*
400V 550V meter Material HxWxD HxWxD
ELC009 4kW 5.5kW 7-10A /IS /AM /S or /P B = 24V 300 x 250 x 200 240 x 190 x 160
ELC012 5.5kW 7.5kW 9-13A /IS /AM /S or /P 300 x 250 x 200 240 x 190 x 160
ELC018 7.5kW 11kW 12-18A /IS
/AM /S or /P E = 48V 300 x 250 x 200 240 x 190 x 160
ELC025 11kW 15kW 17-25A /IS /AM /S or /P 300 x 250 x 200 300 x 220 x 180
ELC032 15kW 18.5kW 23-32A /IS /AM /S or /P F = 110V 300 x 250 x 200 300 x 220 x 180
ELC040 18.5kW 22kW 30-40A /IS /AM /S U = 240V 400 x 300 x 200 -
ELC050 22kW 30kW 37-50A /IS /AM /S 400 x 300 x 200 -
ELC065 30kW 37kW 48-65A /IS /AM /S N = 415V 400 x 300 x 200 -
ELC080 37kW 45kW 63-80A /IS /AM /S 600 x 400 x 260 -
ELC095 45kW 55kW 80-93A /IS /AM /S SF = 550V 600 x 400 x 260 -
ELC115 55kW 75kW 100-160A /IS /AM /S B = 24V 700 x 500 x 260 -
Steel Enclosed ELC150 75kW 90kW 100-160A /IS /AM /S F = 110V 800 x 600 x 320 -
shown with isolator & ELC185 90kW 110kW 125-200A /IS /AM /S 1000 x 600 x 320 -
ammeter ELC225 110kW 132kW 160-250A /IS /AM /S P = 230V 1000 x 600 x 320 -
ELC265 132kW 160kW 200-315 /IS /AM /S V = 400V 1200 x 800 x 320 -
ELC330 160kW 220kW 250-400A /IS /AM /S 1200 x 800 x 320 -
ELC400 220kW 275kW 315-500A /IS /AM /S SF = 550V 1675 x 600 x 400 -
Note: When requesting a price or when ordering a starter with optional extra from list below, please order optional extra as a
separate line. Order example:
1) 4kW, 400V, with Isolator,Ammeter, Hour Meter, Phase Failure monitor, Steel enclosure, 240V coil.
Item 1: ELC009/IS/AM/S U
Item 2: EFS05
Item 3: EFS18
DOL Reversing Starters
Complete with mechanical and electrical interlocks and thermal overload relay. Steel Enclosure IP65 or
Polycarbonate Enclosure IP56. Enclosed starters can be customised by adding items from Optional Extras table below.
Open Enclosed Motor Motor Overload Standard Options Enclosure Coil Enclosure
Starter Starter kW @ kW @ Range Isolator Ammeter Material Voltage Size*
400VAC 550VAC HxWxD
RC009A ERC009A 0.37kW 0.55kW 1-1.6A /IS /AM /P B = 24V 240 x 190 x 160
Open RC009B ERC009B 0.55-0.75kW 1.5kW 1.6-2.5A /IS /AM /P 240 x 190 x 160
Plastic Enclosed RC009C ERC009C 1.1-1.5kW 2.2kW 2.5-4A /IS /AM /P 240 x 190 x 160
*Standard panel sizes RC009D ERC009D 2.2kW 3kW 4-6A /IS /AM /P F = 110V 240 x 190 x 160
listed. Change /P or /S
if required. RC009E ERC009E 3kW 4kW 5.5-8A /IS /AM /P 240 x 190 x 160
Note:
The selection of optional RC009 ERC009 4kW 5.5kW 7-10A /IS /AM /P 240 x 190 x 160
extras may impact on the
enclosure size. RC012 ERC012 5.5kW 7.5kW 9-13A /IS /AM /P U = 240V 240 x 190 x 160
For accurate quotation
please contact our RC018 ERC018 7.5kW 11kW 12-18A /IS /AM /P 240 x 190 x 160
panel shop.
RC025 ERC025 11kW 15kW 17-25A /IS /AM /S 400 x 300 x 200
RC032 ERC032 15kW 18.5kW 23-32A /IS /AM /S N = 415V 400 x 300 x 200
RC40 ERC40 18.5kW 22kW 30-40A /IS /AM /S 500 x 400 x 200
RC50 ERC50 22kW 30kW 37-50A /IS /AM /S 500 x 400 x 200
RC65 ERC65 30kW 37kW 48-65A /IS /AM /S SF = 550V 500 x 400 x 200 MOTOR CONTROL
RC80 ERC80 37kW 45kW 63-80A /IS /AM /S 600 x 400 x 260
Optional Extras - for Enclosed DOL Starters ELC Series & Reversing Starters ERC Series
Code Description Code Description
EFS01 Ammeter selector switch Up to 18.5kW EFS10 Surge Protection - 3-phase, 40kA
EFS02 Ammeter selector switch 22kW+ EFS11 Surge Protection - 3-phase+N, 40kA
EFS03 Voltmeter 72x72, c/w fuses (IP42) EFS12 Emergency Stop
EFS04 Voltmeter selector switch EFS13 Man/Off/Auto selector
EFS05 Running Hour Meter 48x48 EFS14 Man/Off/Auto sel + 24VAC field circuit
EFS06 Surge Protection - 1-phase, 5kA EFS15 Pilot light - Run - Green
EFS07 Surge Protection - 3-phase, 5kA EFS16 Pilot Light - Trip - Red
EFS08 Surge Protection - 3-phase+N, 5kA EFS17 Pilot Light - Power On - Amber
EFS09 Surge Protection - 1-phase, 40kA EFS18 Phase Failure Relay
CO1 140
STAR-DELTA STARTERS & STAR DELTA STARTERS WITH PFC
Star-Delta Starters - Complete with mechanical and electrical interlocks, thermal overload relay and electronic
timer. Steel enclosure IP65 or Polycarbonate Enclosure IP56. Enclosed starters can be customised by adding items
from the Optional Extras table shown below. Control fuses fitted on enclosed starters ≥ 5.5kW.
Open Enclosed Motor kW Motor kW Overload Standard Options Encl. Coil Standard
Starter Starter @400VAC @550VAC Range Isolator Ammeter Mate- Voltage Encl. Size
rial Lx WxH
DC009A EDC009A 4kW 5.5kW 4-6A /IS /AM /P B = 24V 240 x 190 x 160
DC009B EDC009B 5.5kW 7.5kW 5.5-8A /IS /AM /P 240 x 190 x 160
DC009 EDC009 7.5kW 11kW 7-10A /IS /AM /P F = 110V 240 x 190 x 160
DC012 EDC012 11kW 15kW 9-13A /IS /AM /P 240 x 190 x 160
Open Type DC018 EDC018 15kW 18.5kW 12-18A /IS /AM /P FT* = 110V 240 x 190 x 160
EDC-Type - Plastic Enclosed
DC025 EDC025 18.5kW 22kW 17-25A /IS /AM /P 300 x 220 x 180
DC032 EDC032 22kW 30kW 23-32A /IS /AM /P U = 240V 300 x 220 x 180
DC038 EDC038 30kW 37kW 28-36A /IS /AM /P 300 x 220 x 180
DC040A EDC040A 37kW 45kW 37-50A /IS /AM /S UT*= 240V 500 x 400 x 200
DC050 EDC050 45kW 55kW 37-50A /IS /AM /S 600 x 400 x 260
DC065 EDC065 55kW 75kW 48-65 /IS /AM /S N = 415V 600 x 400 x 260
DC080 EDC080 75kW 90kW 63-80A /IS /AM /S 700 x 500 x 260
DC095 EDC095 90kW 110kW 80-93A /IS /AM /S SF = 550V 700 x 500 x 260
DC115 EDC115 110kW 132kW 100-160A /IS /AM /S B = 24V 1000 x 800 x 320
DC150 EDC150 132kW 160kW 100-160A /IS /AM /S F = 110V 1000 x 800 x 320
DC185 EDC185 160kW 200kW 125-200A /IS /AM /S FT* = 110V 1000 x 800 x 320
DC225 EDC225 220kW 250kW 160-250A /IS /AM /S P = 230V 1200 x 800 x 320
DC265 EDC265 250kW 315kW 200-315A /IS /AM /S PT* = 230V 1200 x 800 x 320
DC330 EDC330 315kW 400kW 250-400A /IS /AM /S V = 400V 1575 x 800 x 400
DC400 EDC400 375kW 450kW 315-500A /IS /AM /S SF = 550V 1575 x 800 x 400
Change /P or /S if required.
* Starter c/w Control Transformer. To specify Control Transformer primary voltage add: 4 (400V), 5 (550V).
EDC-Type - Steel Enlosed Note: The selection of optional extras may impact the enclosure size. For accurate quotation contact our panel shop.
Note: When requesting a price or when ordering a starter with optional extras, order the optional extra as a separate line.
Order example: 1) 4kW, 400V, with Isolator,Ammeter, Hour Meter, Phase Failure monitor, Steel enclosure, 240V coil.
Item 1: EDC009/IS/AM/S U Item 2: EFS05 Item 3: EFS18
Star-Delta with Static Power Factor Correction (PFC) IP42
Complete with isolator, ammeter, mechanical and electrical interlocks, thermal overload relay, 2 x electronic timers,
cooling fans, HRC control fuses, capacitor switching contactor and 3PH capacitor. Starters can be customised by
adding items from the Optional Extras table shown below.
Code Motor Kw Overload Compensation Coil Voltage Standard Encl. Size
@400VAC Range @400V LxWxH
MOTOR CONTROL Note: Star-Delta starters with EDCP018 15kW 12 - 18A 4 kVAr F = 110V
power factor correction are only EDCP025 18.5kW 17 - 25A 6 kVAr
available in ventilated steel EDCP032 22kW 23 - 32A 8,5 kVAr U = 240V
enclosures. Compensation is EDCP038 30kW 28 - 36A 10,5 kVAr
calculated for 4 pole motors only, EDCP040A 37kW 37 - 50A 13 kVAr N = 415V
to meet or exceed 0.95 PF. EDCP050 45kW 37 - 50A 13 kVAr F = 110V
EDCP065 55kW 48 - 65A 17 kVAr P = 230V
EDCP080 75kW 63 - 80A 22 kVAr V = 400V
EDCP095 90kW 80 - 93A 26 kVAr
EDCP115 110kW 100 - 160A 29 kVAr
EDCP150 132kW 100 - 160A 32 kVAr
Optional Extras - for Enclosed Starters
Code Description Code Description
EFS01 Ammeter selector switch Up to 18.5kW EFS10 Surge Protection - 3-phase, 40kA
EFS02 Ammeter selector switch 22kW+ EFS11 Surge Protection - 3-phase+N, 40kA
Note: The selection of EFS03 Voltmeter 72x72, c/w fuses (IP42) EFS12 Emergency Stop Pushbutton
optional extras may impact EFS04 Voltmeter selector switch EFS13 Man/Off/Auto selector
on the enclosure size. For EFS05 Running Hour Meter 48x48 EFS14 Man/Off/Auto sel + 24VAC field circuit
accurate quotation please EFS06 Surge Protection - 1-phase + N, 5kA EFS15 LED Pilot light - Run - Green
contact our panel shop. EFS07 Surge Protection - 3-phase, 5kA EFS16 LED Pilot Light - Trip - Red
EFS08 Surge Protection - 3-phase + N, 5kA EFS17 LED Pilot Light - Power On - Amber
EFS09 Surge Protection - 1-phase + N, 40kA EFS18 Phase Failure Relay SPR3
141 CO1
MANUAL MOTOR STARTERS
With thermal overload and magnetic short-circuit release
Back-up fuses With Current Limiter
(gL, aM) [A]
kA NM1-SB Adj. Code
230V 400V 500V 230V 400V 500V kA range
230V 400V
0.1 - 0.16A NM1-0.16
No additional No additional No additional 0.16 - 0.25A NM1-0.25
protective protective protective 0.25 - 0.40A NM1-0.4
installations installations installations 0.40 - 0.63A NM1-0.63
necessary. necessary. n ecessary. 0.63 - 1.0A NM1-1
1.0 - 1.6A NM1-1.6
50 1.6 - 2.5A NM1-2.5
25 3 100 50 2.5 - 4.0A NM1-4
35 3 100 50 4.0 - 6.3A NM1-6.3
Phase failure sensitivity according to IEC 947-4-1 50 3 100 50 6.3 - 10A NM1-10
Ambient temperature -25...+40°C (enclosed) 80 50 6 3 100 50 10 - 16A NM1-16
Operating voltage Ue 690V 80 80 63 10 6 3 100 50 16 - 20A NM1-20
Current heat loss 6.0W (total)
80 80 63 10 6 3 100 50 20 - 25A NM1-25
Intrinsically safe up to 6kA @ 400VAC
Enclosures & Fittings
Code Description
NM1-G1 Surface mounting enclosure - IP55 Insulated with entries 4 x M20 threaded
NM1-FP1 Flush mounting enclosure - IP55 For flush-mounting in enclosures,
switchboard or machines
NM1-PV Emergency Stop Button - Latch-in, twist to release
NM1-VS Padlock Device to lock an enclosed starter in the OFF position using up to
3 padlocks (6-8mm shackle)
NM1-G1 NM1-FP1 Accessories
NM1-PV NM1-VS
Code Description
NM1-HS NM1-SB
NM1-U NM1-B13 Auxiliary Contacts
NM1-HS11 UI = 500V Ith = 6A Side mount Aux 1NO +1NC
NM1-HS02 AC11: 3.5A at 250V, 2A at 400V Side mount Aux 2NC
NM1-EHS11 Internal mount Aux 1NO +1NC
*Side mount alarm contact 1NC
NM1-ESS01
*Alarm contacts o perate on thermal or magnetic trip. NC on tripped condition
Undervoltage Release (Internal Mounting)
NM1-U230V Actuating voltage ≤85% Vn 230V
NM1-U400V Tripping voltage 35-75% Vn 400V
Rated duty 100% (uninterrupted)
Heat Loss 1.8W
Fitting of accessories: Internal mount, one per starter. Side mount, max two per starter. MOTOR CONTROL
Current Limiter
NM1-SB For increasing the breaking capacity of not intrinsically safe MMS to 50kA
Busbars at 400V. Rated continuous current 32A.
Also for use as group back-up protection: 4 x 10 or 2 x 16A
NM1-B02 For starters without 2 way 90mm
NM1-B03 External Aux Contact 3 way 136mm
NM1-B04 4 way 180mm
NM1-B12 For starters with 2 way 99mm
NM1-B13 RH External Aux fitted 3 way 153mm
NM1-B14 4 way 207mm
NM1-B15 5 way 261mm
CON 142
MOTOR PROTECTION CIRCUIT BREAKER MPCB
Motor Protection Circuit Breaker - 32A Frame - High Breaking Capacity
Code Rated Thermal Magnetic 400/415V 3-phase [kW] (50/60Hz)
Operational Release Release 230V 400V 500V 690V
Adjustment Operating Icu Ics
Current Range Current [kA] [kA]
Ie
[A] [A] [A]
TCMS-32H 0.16 0.16 0.1-0.16 2.1 100 100 - 0.02 - -
TCMS-32H 0.25 0.25 0.16-0.25 3.3 100 100 0.03 0.06 - -
TCMS-32H 0.4 0.4 0.25-0.4 5.2 100 100 0.06 0.09 - -
TCMS-32H 0.63 0.63 0.4-0.63 8.2 100 100 0.09 0.12 0.25 0.25
TCMS-32H 1 1 0.63-1.0 13 100 100 0.12 0.25 0.37 0.55
TCMS-32H 1.6 1.6 1.0-1.6 20.8 100 100 0.25 0.55 0.55/0.75 1.1
TCMS-32H 2.5 2.5 1.6-2.5 32.5 100 100 0.37 0.75 1.1 1.5
TCMS-32H 4 4 2.5-4.0 52 100 100 0.75 1.5 1.5/2.2 3
TCMS-32H 6 6 4-6 78 100 100 1.5 2.2 3 4
TCMS-32H 8 8 5-8 104 100 100 1.5 3 3.7 5.5
TCMS-32H 10 10 6-10 130 100 100 3 4 4/5.5 7.5
TCMS-32H 13 13 9-13 169 100 100 3 5.5 7.5 11
TCMS-32H 17 17 11-17 221 50 38 4 7.5 11 11
TCMS-32H 22 22 14-22 286 50 38 4 7.5 11 15
TCMS-32H 26 26 18-26 338 50 38 5.5 11 15 18.5
TCMS-32H 32 32 22-32 416 50 38 7.5 15 18.5 22
Motor Protection Circuit Breaker - 63A Frame - High Breaking Capacity
Rated Thermal Magnetic 400/415V 3-phase [kW] (50/60Hz)
Operational Release Release
Code Adjustment Operating Icu Ics
Current Range Current [kA] [kA]
Ie 230V 400V 500V 690V
[A] [A] [A]
TCMS-63H 32 32 22-32 416 50 50 7.5 15 18.5 22
TCMS-63H 40 40 28-40 520 50 50
TCMS-63H 50 50 34-50 650 50 50 7.5 18.5 22 30
TCMS-63H 63 63 45-63 819 50 50
11 22 30 45
15 30 37 55
Motor Protection Circuit Breaker - 100A Frame - High Breaking Capacity
Code Rated Thermal Magnetic 400/415V 3-phase [kW] (50/60Hz)
Operational Release Release 230V 400V 500V 690V
Adjustment Operating Icu Ics
Current Range Current [kA] [kA]
Ie
[A] [A] [A]
TCMS-100H 63 63 45-63 819 100 50 15 30 37 55
TCMS-100H 75 75 55-75
TCMS-100H 90 90 70-90 975 100 50 22 37 45 63
TCMS-100H 100 100 80-100
1170 100 50 30 45 55 75
MOTOR CONTROL 1300 100 50 30 45 63 90
TCMS-32H TCMS-62H TCMS-100H
143 CO1
MOTOR PROTECTION CIRCUIT BREAKER MPCB
Accessories
Code Description
Auxiliary Contacts
• TFX Front mounting Auxiliary contacts - One module per MPCB
TFX • TLX Left side mounting Auxiliary contacts - One module per MPCB
• TLX modules can be stacked on top of TLA and TLAM alarm contacts
TFX-11 Aux Switch for MPCB front mounting - 1NO1NC
TFX-20 Aux Switch for MPCB front mounting - 2NO
TFX-02 Aux Switch for MPCB front mounting - 2NC
TLX-11 Aux Switch for MPCB left side mounting - 1NO1NC
TLX-20 Aux Switch for MPCB left side mounting - 2NO
TLX TLX-02 Aux Switch for MPCB left side mounting - 2NC
Alarm Contacts
• Alarm contacts must be installed first when being used with TLX module
• TLA and TLAM modules cannot be stacked together
• Refer to diagram on left for maximum configuration
TLA-11 Trip Alarm Switch for MPCB left side mounting - 1NO1NC
TLA-20 Trip Alarm Switch for MPCB left side mounting - 2NO
TLA-02 Trip Alarm Switch for MPCB left side mounting - 2NC
TLAM-11 Magnetic Trip Alarm Switch for MPCB left side mounting - 1NO1NC
TLA, TLAM TLAM-20 Magnetic Trip Alarm Switch for MPCB left side mounting - 2NO
TLAM-02 Magnetic Trip Alarm Switch for MPCB left side mounting - 2NC
Shunt Release
• Right side mounting
• One right side mounting module per MPCB
TRS-24V 24V 50Hz / 28V 60Hz
TRS-110V 110V 50Hz/ 120V 60Hz
TRS-230V 220-230V 50Hz / 240-260V 60Hz
TRS-400V 380-400V 50Hz / 440-460V 60Hz
Undervoltage Release
• Right side mounting
• One right side mounting module per MPCB
TRU-24V 24V 50Hz / 28V 60Hz
TRU-110V 110V 50Hz/ 120V 60Hz
TRU-230V 220-230V 50Hz / 240-260V 60Hz
TRU-400V 380-400V 50Hz / 440-460V 60Hz
Undervoltage Release with Auxiliary
• Right side mounting
• Includes 2 NO Aux
• One right side mounting module per MPCB
TRUX-24V 24V 50HZ / 28V 60Hz
TRUX-110V 110V 50Hz/ 120V 60Hz
TRUX-230V 220-230V 50Hz / 240-260V 60Hz
TRUX-400V 380-400V 50Hz / 440-460V 60Hz MOTOR CONTROL
Mounting Accessories
TPIL32 Mounting Lug for securing the TCMS-32 onto chassis plate
TIB100 Insulation barrier for TCMS-100
EPH32-65S IP65 enclosure to accomodate TCMS-32
MU-45 TPIL32 MEH TDA32HA* Direct adaptor used to connect TCMS-32 directly with a mini
contactor
MU45* Mounting unit to connect TCMS-32 with a mini contactor
TDA-32HA MEH32-115 Pad-lockable vari-depth rotary handle for use with TCMS-32
MEH63-115 Pad-lockable vari-depth rotary handle for use with TCMS-63
MEH100-115 Pad-lockable vari-depth rotary handle for use with TCMS-100
*Items used for Type 2 co-ordination
CO1 144
VACUUM CONTACTORS
CSOOMOINNG! Vacuum Contactors - 3P
CV-80/1.14 Code Rated Rated Rated Rated Auxiliary Mecha- Electrical Pick-Up Hold Wei-
Current Voltage Making Breaking Contacts nical Life Life Power Power ght
CKJ11-160 Capacity Capacity (W) (W)
960A
CV-80/1.14 80A 1.14kV 1600A 800A 2NO/1NC 1 000 000 60 000 270W 10W 1.8kg
1.5kV 2500A
CKJ11-400 CKJ11-160/1.5-* 160A 1.5kV 1280A 3NO/1NC 1 000 000 60 000 265W 30W 3.5kg
CKJ11-250/1.5-* 250A 2000A 3NO/1NC 1 000 000 60 000 265W 30W 5kg
CKJ11-400/1.5-* 400A 1.5kV 4000A 3200A 4NO/1NC 1 000 000 60 000 342W 38W 7.5kg
CKJ11-630/3.6-* 630A 3.6kV 6300A 5000A 4NO/2NC 1 000 000 60 000 400W 45W 10kg
CKJ11-630 *Add Control Voltage to code: 110V, 230V, 400V - All sizes supplied with auxiliary contacts
CKJ11-250 2 POLE CONTACTORS
TCDP 2 Pole Contactors - Suitable for air conditioners
Rated Volts: 550VAC Code Rating A (AC1) No. of Poles Terminals
Cable Entry: 20mm
IP42 TCDP202-* 20A 2 N/O Screw/PushOn
Screw/PushOn
TCDP302-* 30A 2 N/O Screw/PushOn
TCDP402-* 40A 2 N/O
*Add coil voltage: M = 240VAC, Q = 400VAC
Heavy Duty Relay
G7LB-2A* 25A 2 N/O Clamp
*Add coil voltage: 24VAC, 110VAC, 230VAC G7LB-2A
MINI CONTACTORS
Code Auxiliary Max ratings for application Max ratings for application on
FDC-K0910* Contacts of 3-phase motors - AC3 resistive heating loads - AC1
N/O 9A@400V 4kW@400V 20A@400V
FDC-K0901* N/C 9A@400V 4kW@400V 20A@400V
*Add coil voltage: B = 24VAC, F = 110VAC, M = 230VAC, Q = 400VAC
Spare Coil Code FDC-D2* *Add voltage: B = 24VAC, F = 110VAC, M = 230VAC, Q = 400VAC
MOTOR START PUSH BUTTONS
Direct Motor Starters for Three Phase Motors
IP42
MOTOR CONTROL Code SP-315 SP-330 SY-315 SY-330
Rated Current 15A 30A 15A 30A
Rated Power
Mounting 0-2.2kW 0-3.7kW 0-2.2kW 0-3.7kW
Material Surface Surface Flush Flush
Steel Steel Steel Steel
IP55
Single Phase IP55 Three Phase
IP55 IP55 IP55
Code SDZ-6A SDZ-6B SDZ-6E SDZ-08B SDZ08-8
15A 15A
Rated Current 15A 15A 12A (AC-3)
Rated Power 2.2kW (AC-3) 2.2kW (AC-3) 2.2kW (AC-3) 2.2kW (AC-3) 3PH 400VAC
Cutout Size 50 x 23mm 50 x 23mm 46 x 22mm Surface Mount Surface Mount
• Power Failure Protection • Under Voltage Protection CO1
145
MINI 3-POLE CONTACTORS & OVERLOAD RELAYS
Electronic Timer Coil Supressor Auxiliary Contact
configurations
Current AC3@415V 6A 9A 12A 16A
Code* 1N/O Aux TC1-M0610* TC1-M0910* TC1-M1210* TC1-M1610*
Code* 1N/C Aux TC1-M0601* TC1-M0901* TC1-M1201* TC1-M1601*
Rated operating voltage 690VAC 690VAC 690VAC 690VAC
AC1 Duty Resistive Load 20A 20A 20A 20A
AC3 Duty Current rating
AC3 Duty Power rating 6A@380/440V 9A@380/440V 12A@380/440V 16A@380/440V
AC3 Duty Power rating 2.2kW@380/440V 4kW@380/440V 5.5kW@380/440V 7.5kW@380/440V
Coil Consumption Inrush/sealed 3kW@500/550V 3.7kW@500/550V 4kW@500/550V 5.5kW@500/550V
Mechanical life (million ops)
Electrical life (million ops) 32/6VA 32/6VA 32/6VA 32/6VA
Size H x W x D 12 12 12 12
Mounting Rail 1 1 1 1
58 x 45 x 57mm 58 x 45 x 57mm 58 x 45 x 57mm 58 x 45 x 57mm
DIN / Chassis DIN / Chassis DIN / Chassis DIN / Chassis
*Add coil voltage to code: B = 24VAC E = 48VAC F = 110VAC M = 220VAC N = 415VAC
Thermal Overload Relay for use with mini contactors - c/w 1NO+1NC Auxiliary Contacts
Aux & Coil Terminals Extended Code Relay Range KW @400V Code Relay Range KW @400V
through overload TR2-M0.14A 0.10-0.16A - TR2-M3.3A 2.5-4A 1.1-1.5kW
TR2-M0.21A 0.16-0.25A - TR2-M5A 4-6A 2.2kW
TR2-M0.33A 0.25-0.4A - TR2-M6.5A 5-8A 3.kW
TR2-M0.52A 0.4-0.63A - TR2-M7.5A 6-9A 3.5kW
TR2-M0.82A 0.63-1A - TR2-M8.5A 7-10A 4.0kW
TR2-M1.3A 1-1.6A 0.37kW TR2-M11A 9-13A 5.5kW
TR2-M2.1A 1.6-2.5A 0.55-0.75kW TR2-M14A 12-16A 7.5kW
Ambient compensated -5°C to 40°C Automatic/Manual reset site selectable
Auxiliaries Top And Side Mount - Ith = 10A
Code Contact Code Contact Mounting
Configuration Mounting Configuration
TA1-M22 2NO + 2NC Front
TA1M40 TA1-M20 2NO Front TA1-M13 Front
TA1-M04 1NO + 3NC Front
TA1M20 TA1-M11 1NO + 1NC Front TA8-M01 Side
TA8-M10 4NC Side
Coil TA1-M02 2NC Front
Supressor 1NC
TA8 TA1-M40 4NO Front
TA9-M978 1N0
TA1-M31 3NO + 1NC Front
Accessories Description MOTOR CONTROL
Code
Mechanical Interlock for TC1-M06-M16 for horizontal mounting
TA9-M978 Coil Supressor for 24-48VAC coils
TA9-M980-1 Coil Supressor for 60-127VAC coils
TA9-M980-2 Coil Supressor for 200-240VAC coils
TA9-M980-3
AC Mini Control Relay - Ith = 20A Uc = 690VAC
Code Contact Configuration
TCA2-M22* 2NO + 2NC
TCA2-M31* 3NO + 1NC
TCA2-M40* 4NO
TCA2-M13* 1NO + 3NC
TCA2-M04* 4NC
*Add coil voltage to code: B = 24VAC E = 48VAC F = 110VAC M = 220VAC N = 415VAC
CO1 146
AC CONTACTORS & OVERLOADS
3 & 4 Pole Contactors AC Coil
INMEDPWREOSIVGEND with Front Dust Cover
CB Certification
All ratings are for ambient temperature upto
40°C and 2000m above sea level.
D09-D95 supplied with wide range coils
Code* 1N/O Aux TC1- D0910 D1210 D1810 D2210 D2510 D3210 D3810 D40 D50 D65 D80 D95
Code* 1N/C Aux TC1- D0901 D1201 D1801 D2201 D2501 D3201 D3801 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC
Code* 4 Pole Contactors TC1- D09004 D12004 D18004 D25004
Code* 4 Pole 2NO/2NC TC1- D09008 D12008 - - D25008 - - D40004 D50004 D65004 D80004 D95004
- - - D40008 D50008 D65008 D80008 D95008
Rated operating voltage AC 690V 690V 690V 690V 690V 690V 690V 690V 690V 690V 690V 690V
AC1 Duty Resistive Load 25A 25A 32A 32A 40A 50A 50A 60A 80A 80A 125A 125A
AC3 Duty Current rating 400V 9A 12A 18A 22A 25A 32A 38A 40A 50A 65A 80A 95A
AC3 Duty Power rating 400V 4kW 5.5kW 7.5kW 11kW 11kW 15kW 18.5kW 18.5kW 22kW 30kW 37kW 45kW
550V 5.5kW 7.5kW 11kW 12.5kW 15kW 18.5kW 18.5kW 22kW 30kW 37kW 45kW 55kW
1000V - - - - - - - - - - - -
AC4 Duty 200K ops 400V 2.2kW 3.7kW 4kW 4.5kW 5.5kW 7.5kW 7.5kW 9kW 11kW 11kW 15kW 15kW
Star-Delta Power rating 400V 7.5kW 11kW 15kW 15kW 18.5kW 22kW 30kW 37kW 45kW 55kW 75kW 90kW
550V 7.5kW 11kW 18.5kW 18.5kW 22kW 37kW 37kW 45kW 55kW 75kW 90kW 110kW
Generator Set 400V 17kVA 17kVA 22kVA 22kVA 27kVA 34kVA 38kVA 42kVA 55kVA 55kVA 85kVA 85kVA
Electrical life (million ops) AC3 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6
Power Dissipation/Pole AC1 1.56W 1.56W 2.5W 2.5W 3.2W 5W 5W 5.4W 9.6W 6.4W 12.5W 12.5W
Coil Consumption Inrush/sealed 50Hz 60/7VA 90/7.5VA 200/20VA
Cable Size required 50/ 4mm2 4mm2 6mm2 6mm2 10mm2 10mm2 10mm2 16mm2 25mm2 25mm2 35mm2 35mm2
for AC 1 Duty 60Hz
Size H x W x D - 3 Pole mm 74 x 45 x 80 84 x 56 x 93 127 x 75 x 114 127 x 85 x 125
Mounting Rail DIN 35mm 35mm 35/70mm 35/70mm
Spare Coils
Code TX1-D2* TX1-D4* TX1-D6*
Coil Voltages*
J = 12V 50/60Hz (10.2-13.2V) N = 415V 50Hz (352-465V) S = 500V 50Hz (425-550V) SF = 550V 50Hz (467-605V)
B = 24V 50/60Hz (20.4-26.4V)
E = 48V 50/60Hz (41-53V)
F = 110V 50/60Hz (77-121V)
U = 240V 50Hz (170-280V)
Thermal Overload Relays
MOTOR CONTROL Code Range kW@400V Code Range Code Range kW@400V
TR2-D09303 TR2-D40353 23 - 32A 15kW
TR2-D09304 0.25 - 0.40A 0.37kW TR2-D25322 17 - 25A TR2-D40355 30 - 40A 18.5kW
TR2-D09305 0.40 - 0.63A 0.55 - 0.75kW (11kW@400V) TR2-D65357 37 - 50A 22kW
TR2-D09306 0.63 - 1.00A 1.1 - 1.5kW TR2-D65359 48 - 65A 25 - 30kW
TR2-D09307 1.00 - 1.60A 2.2kW TR2-D32353 23 - 32A TR2-D65361 55 - 70A 30 - 37kW
TR2-D09308 1.60 - 2.50A 3.0kW (15kW@400V) TR2-D80363 63 - 80A 37kW
TR2-D09310 2.50 - 4.00A 4.0kW TR2-D95365 80 - 93A 45kW
TR2-D09312 4.00 - 6.00A 5.5kW TR2-D32355 28 - 36A
TR2-D09314 5.50 - 8.00A 7.5kW (18.5kW@400V)
TR2-D12316 7.00 - 10.00A
TR2-D18321 9.00 - 13.00A
12.00 - 18.00A
147
CO1
World class 1000V CONTACTORS & OVERLOADS
accreditation 780A
UL508-17th edition
CSA22.2 No.14-95
CB Certification
LC1-FDP... 150A 185A 225A 265A 330A 400A 500A 630A 780A*
115A
1504A Use same auxillaries as TC1 contactors. Each contactor accepts up to 2 add-on units. Refer to page 3 7804A*
1154A - -
- 1854A 2254A 2654A 3304A 4004A 5004A 6304A
1000V 1000V
1000V 250A - -- - - -- 1600A
200A 150A 780A
115A 75kW 1000V 1000V 1000V 1000V 1000V 1000V 1000V 400kW
55kW 90kW 450kW
75kW 75kW 275A 315A 350A 400A 500A 700A 1000A 450kW
65kW 22kW 110kW
18.5kW 132kW 185A 225A 265A 330A 400A 500A 630A
110kW 160kW –
132kW 165kVA 90kW 110kW 132kW 160kW 200kW 250kW 335kW –
135kVA 2.4 1100kVA
2.4 25W 110kW 129kW 160kW 200kW 257kW 355kW 400kW 0.8
18W 550/45VA 250W
550/45VA 100kW 100kW 147kW 160kW 185kW 335kW 450kW 2100/50VA
40kW 45kW 55kW 63kW 75kW 80kW 100kW
160kW 200kW 250kW 315kW 375kW – –
220kW 250kW 315kW 375kW 425kW – –
185kVA 225kVA 240kVA 280kVA 350kVA 475kVA 680kVA
2.4 2.4 2.4 2.4 2.4 2.4 1.2
26W - 39W - 70W 88W 120W
805/55VA 805/55VA 1200/95VA 700/10VA 1075/15VA 1100/18VA 1650/22VA
50mm2 70mm2 95mm2 Flexibar Flexibar Flexibar Flexibar Flexibar Flexibar Flexibar
24 x 4mm 24 x 4mm 24 x 4mm 24 x 5mm
24 x 5mm 24 x 10mm 50 x 5mm
162 x 164 x 173 174 x 169 x 185 197 x 169 x 185 203 x 202 x 207 206 x 206 x 223 206 x 213 x 226 238 x 233 x 238 304 x 309 x 260 434 x 702 x 250
Chassis Mounted * 2 x Coils - Coils to be Ordered Separately
AC Coils
Code LX1-FF* LX1-FG* LX1-FH2* LX1-FJ* LX1-FK* LX1-FL* LX1-FX*
LX1 Coil
Coil Voltages* Thermal Overload Relays
Internal CT's, Separate Mounting, 1000V Rated
B = 24V 50Hz (20.4-26.4V)
E = 48V 50Hz (41-53V) Code Range Motor@400V
F = 110V 50Hz (77-121V)
P = 230V 50Hz (195-253V) LR1-F(M)105 65 - 105A 37 - 55 kW
V = 400V 50Hz (340-440V)
S = 500V 50Hz (425-550V) LR1-F160 100 - 160A 75 - 90 kW
SF = 550V 50Hz (467-605V)
LR1-F200 125 - 200A 90 - 110kW
LR1-F250 160 - 250A 110 - 132kW
Overload Base Plate LR1-F315 200 - 315A 132 - 160kW
DIN or Screw Mount LR1-F400 250 - 400A 160 - 220kW
LR1-F500 315 - 500A 200 - 250kW
LR1-F630 400 - 630A 250 - 375kW MOTOR CONTROL
Electronic Overload Relays
Internal CT's, Separate Mounting, 1000V Rated
Code Range Motor@400V
LR9-F5367 60-100A 90 - 110kW
Code To Fit Overload Sizes LR9-F5369 90-150A 110 - 132kW
TA7-D0964
TA7-D3264 From TR2-D09301 LR9-F5371 132-220A 132 - 160kW
TA7-D4064 To TR2-D25322
LR9-F7375 200-330A 160 - 220kW
From TR2-D32353
To TR2-D32355 LR9-F7379 300-500A 200 - 250kW
From TR2-D40353
To TR2-D95365 LR9-F7381 380-630A 250 - 375kW
For more electronic overloads, see pages 132-136
CO1 148
CONTACTORS & CONTROL RELAYS
3 Pole Contactors DC Coils
D09-D80 TP1- D0910* D1210* D1810* D2510* D3210* D4011* D5011* D6511* D8011*
supplied with coil TP1- D0901* D1201* D1801* D2501* D3201* 1NO+1NC
1NO+1NC 1NO+1NC 1NO+1NC
Code* 1N/O Aux 4kW 5.5kW 7.5kW 11kW 15kW 37kW
Code* 1N/C Aux 9W 9W 9W 11W 11W 18.5kW 22kW 30kW 22W
AC3 Rated Power @ 400V 30 30 30 25 25 22W 22W 22W 20
Coil Consumption 84 x 56 x 130 127 x 85 x 181
Mechanical Life (million ops) 74 x 45 x 115 20 20 20
Dimensions H x W x D mm 127 x 75 x 168
Spare Coils
Code TX4-D2* TX4-D4* LX4-D40* LX4-D80*
* Voltage DC JD = 12VDC BD = 24VDC ED = 48VDC FD = 110VDC MD = 220VDC
Contactors for 3 Phase PF Correction Capacitors
Internal diagram of Contactor Conforms to AC6b
IEC 60947-4-1
D12K-D75K
supplied with coil
Code* 1N/O + 1N/C TC1- D12K11* D16K11* D20K11* D25K11* D33K12* D40K12* D60K12* D75K12*
Code* 2N/C TC1- D12K02* D16K02* D20K02* D25K02* 1NO+2NC 1NO+2NC 1NO+2NC 1NO+2NC
Rated operating voltage 690V 690V 690V 690V 690V 690V 690V 690V
Capacitor switching 60kVAr 75kVAr
400V 12.5kVAr 16.7kVAr 20kVAr 25kVAr 33.3kVAr 40kVAr
* Add Coil Voltage F = 110V 50/60Hz U = 240V 50Hz N = 415V 50Hz
Reversing Contactors (Wide range of AC coilsAC Coils) AC Control Relays DC Control Relays
MOTOR CONTROL Code AC3 400V Aux Contacts Code Contacts Code Contacts
TC2-D0901* 4kW 1N.C. TCA2-DN22* 2N.O. + 2N.C. TCA3-DN22* 2N.O. + 2N.C.
TC2-D1201* 5.5kW 1N.C. TCA2-DN31* 3N.O. + 1N.C. TCA3-DN31* 3N.O. + 1N.C.
TC2-D1801* 7.5kW 1N.C. TCA2-DN40* 4N.O. TCA3-DN40* 4N.O.
TC2-D2501* 11kW 1N.C. Uc = 12-600V Uc = 12-600V
TC2-D3201* 15kW 1N.C. Ith = 10A Ith = 10A
TC2-D4011* 18.5kW 1N.O. + 1N.C. Max ops per sec = 3 Max ops per sec = 3
TC2-D5011* 22kW 1N.O. + 1N.C. Mechanical life: Mechanical life:
TC2-D6511* 30kW 1N.O. + 1N.C. 50Hz coil 20m ops DC coil 30m ops
TC2-D8011* 37kW 1N.O. + 1N.C. 50/60Hz coil 30m ops
TC2-D9511* 45kW 1N.O. + 1N.C.
* C oil Voltage AC J = 12V 50Hz (9-32A only) B = 24V 50/60Hz E = 48V 50/60Hz F = 110V 50/60Hz * C oil Voltage DC JD = 12VDC
U = 240V 50Hz N = 415V 50Hz SF = 550V 50Hz V = 400V 50Hz P = 230V 50Hz S = 500V 50Hz BD = 24VDC ED = 48VDC
FD = 110VDC MD = 220VDC
149 CO1