DATA ACQUISITION & DISTRIBUTION

ACCESSORIES

Backplane for Power and
Communication

Code S401-L EASY SETUP SOFTWARE
Description Plug & Play set-up software for
OLED brightness display: 2,7" Interfaces: programmable devices
1 x RS485 Modbus Master +
1 x RS485 Modbus Slave

+ ++ Code Description
Z-PC-DINAL2-17.5 Head + 2 Slots
Code DATA RECORDER SOFTWARE S117P-1 Z-PC-DIN2-17.5 2 Slots
Z-PC-DIN8-17.5 8 Slots
Data acquisition Programming kit for head mount temp. Z-PC-DINAL2-35 Head + 1 Slots
visualisation & transmitters. Consists of: Serial Cables, USB to Z-PC-DIN1-35 1 Slot
recording software. RS232/TTL, Config. software Z-PC-DIN4-35 4 Slots

Cable Accessories

Code Description Terminal Type
RJ10/ DB9F
PM001420 RS232 serial cable (Z-TWS, Z-RTU, Z107, Z-LINK) RJ10/ DB25M
PM001430 Modem communication cable (Z-TWS) RJ10/ DB25M
PM001440 Modem and HMI communication cable (ZTWS, Z-RTU) RJ45/ RJ45
PM001450 Ethernet cable-right (Z-TWS - network device) RJ45/ RJ45
PM001460 Crossing Ethernet cable ( Z-TWS-PC) RJ10/ DB9M
PM001530 Modem serial cable (Z-TWS, Z-RTU) Jack/ DB9F
PM001601 Programming serial cable (Z-4AI-D, Z-4TC-D, Z8AI, Z-8TC, Z-4RTD2, Z-SG, Z203) DB9M/ Bolt Heads
PM002350 RS485 serial cable for Radio modem Tp-wire/ Bolt heads
PM002460 RS485 serial cable TP-WIRE (Z-TWS) RJ10/ RJ10
PM002470 Serial cable (Z-TWS, Z-RTU, Z107) RJ10/ Bolt heads
PM002480 RS485 Serial cable (Z-TWS) DB9M/ DB9F
PM002490 RS232 Serial cable - programming (Z-RTU, M-RTU, Radio Modem) DB9M/ DB9F
PM002500 RS232 modem for firmware updating (ZRTU, M-RTU, Radio Modem) DB9F/ Puntali
PM002510 Serial cable for Radio Modem DB9M/ DB9M
PM002520 Serial cable DB9F/ DB9F
PM002530 Serial cable

TRANSMITTERS

Signal Isolator Transmitter

Code S4X-DT-* DC Input Range DC Output Range
V2: 0-5V; V3: 1-5V;
*Add Supply Voltage: A = 85 - 265VAC/100 to 330 VDC or B = 20 - 60VDC V4: 0-10V; A1: 0-1mA; V2: 0-5V; V3: 1-5V; INSTRUMENTS & TELEMETRY
Multi-range Input / Output selectable by solder jumper wire on inside of unit. A3: 0-20mA; A4: 4 -20mA V4: 0-10V; A2: 0-10mA;
(AC/DC Workshop will set Input/Output configuration if requested on ordering) A3: 0-20mA; A4: 4 -20mA
Input - 3 Wire
Potentiometer Transmitter

Code S4X-DT-*

Supply Voltage: AC 85 – 265V/DC 100 – 330V Total Resistance - 100Ω - 10kΩ

RTD (PT100) Transmitter (Isolator)

Code S4X-RR-P*-A4-* DC Output Multi Range (Selectable by Dip Switch)

* Add °C to code: F (0 - 100°C), D (-50 - 200°C), G (0 - 200°C) V2: 0-5V; V3: 1-5V; V4: 0-10V;

* Add Supply Voltage: A = 85 - 265VAC/100 to 330 VDC or B = 20 - 60VDC A1: 0-1mA; A2: 0-10mA; A3: 0-20mA; A4: 4 -20mA

Speed (Frequency Transmitter) Specifications

Code Description Code Description Accuracy: ± 0.1% RO.
Isolation: Input/Output/Power
S4X-RT-B-2-M-A 0-100Hz Input S4X-RT-F-2-M-A 0-2Hz Input Insulation Resistance: ≥ 100MV, DC 500V
Impulse Withstand Test: IEC 1000-4-5, class 4
S4X-RT-E-2-M-A 0-1KHz Input S4X-RT-H-2-M-A 0-10KHz Input
Supply Volts: 85-265VAC Output Programmable: 4-20mA, 0-10V

DPM 258

GENSET CONTROLLERS

All controllers are DSE702 DSE331 DSE4520 DSE6120 DSE7320
suitable for 12/24VDC
systems. Manual Start / Stop ATS AMF AMF AMF
Code N 4 4 4 4
Application 1 4 4 6 8
Config DC Output N
Config Input Dedicated N Can be Configured Can be Configured Can be Configured
Oil Pressure Dedicated Y Can be Configured Can be Configured Can be Configured
Coolant Temp 4 Can be Configured Can be Configured Can be Configured
Remote Start Y N
Config Relay Output N N N N 2
Fuel & Crank Output Y N Y Y Y
Pre Heat relay Output Y N N N N
Analogue Input N N 3 4 4
E-stop Input Y N Y Y Y
Current Input N N Y Y Y
MPU Pick-Up N Y N Y Y
CANbus N N Y Y Y
USB Port N N Y Y Y
RS232 Port N N N N Y
RS485 Port N Y N N Y
Event Logging N Full 50 Events 100 Events 250 Events
PC Config N Y Y Y
Front Config N 180 x 116 x 42 Full Partial Partial
Dimensions (mm) 84 x 72 x 35 154 x 98 140 x 113 x 43 216 x 158 x 42 240 x 181 x 42
Panel Cut Out (mm) 80 x 68 8- 35VDC 118 x 92 182 x 137 220 x 160
Supply 8 - 35VDC 8 - 35VDC 8 - 35VDC 8 - 35VDC

DSE890 Accessories

Code Description

DSE890 Gateway for remote monitoring & control connects to DSE data server by Ethernet, GPRS, RS232 or

RS485. Includes GPS functionality. Suitable for use with controllers with USB Port.
DSE-GSMANT GSM Antenna

DSE-GPSANT GPS Antenna

Automatic Manual Key Start
Transfer Switch Controller

Model EAOM-36 EAOM-7 EAOM-71 ATS-10 EAOM-3
Controls
INSTRUMENTS & TELEMETRY Automatic engine Start/Stop Y Y Y Controls Fuel and stop solenoid
Automatic Shutdown on fault Generator remote start Starter motor
condition Y Y Y Load transfer to mains Manual generator start/ stop
Alternator voltage and fre- Mains and generator Preheat (Glow Plug)
quency measurement Frequency Generator Voltage/ Generator Voltage/ contactor Monitors
Measurement Power Measurement Power Measurement Monitors Engine running time
Load current measurement 3 Phase mains voltage Error Indication
Remote Start/Stop input N 3 Phase 3 x 1 Phase Alternator voltage Fail Monitoring
3 resistive sender units Y Y Y Program parameters Low oil pressure
User configurable inputs N N Y High temperature
User configurable outputs 2 3 3 Over speed failure
Speed sensing off Alternator 1 2 2 Charging fail
Speed sensing off magnetic Y Y Y
Pickup 72 x 72
RS-232 Serial Comms N YY
Remote use from PC
Standard Modem Comms Y Y Y 72 x 72
Display Y Y Y
N Y Y
Size (mm) LED LED LED
72 x 72 96 x 96 96 x 96
259
DPM

ANTI-HARMONIC PFC

Anti-Harmonic PFC Plug-In Systems

Code Code with kVAr at Steps Step values @400V Dimensions
Comms 400V 25kVAr 50VAr H x WxD

VMPH-150 VMPHC-150 150 4 2 2 1600 x 800 x 600
VMPH-175 VMPHC-175 175 4 1 3 1600 x 800 x 600
VMPH-200 VMPHC-200 200 5 2 3 1850 x 800 x 600
VMPH-225 VMPHC-225 225 5 1 4 1850 x 800 x 600
VMPH-250 VMPHC-250 250 6 2 4 2050 x 800 x 600
VMPH-300 VMPHC-300 300 7 2 5 1600 x 1600 x 600
VMPH-350 VMPHC-350 350 8 2 6 1600 x 1600 x 600
VMPH-400 VMPHC-400 400 9 2 7 1600 x 1600 x 600
VMPH-450 VMPHC-450 450 10 2 8 1600 x 2400 x 600
VMPH-500 VMPHC-500 500 11 2 9 1600 x 2400 x 600
VMPH-600 VMPHC-600 600 12 0 12 1600 x 2400 x 600

Connect ready Automatic Power Factor Correction Systems where harmful harmonics exist as caused by

UPS, VSDs and other similar devices. It is always recommended that a detailed site analysis be undertaken

before ordering.

• Robust design for systems subjected to VTHD <7% and ITHD <20%. VTHD<14% on application.

• Top, bottom and side cable entry.

• Plug-in full busbar system.

• Thermostatically controlled forced cooling

• Door interlocked isolator with surge protection and control fuse protection.

• Data acquisition option with GSM comms and PC software. Sim card required.

• Each plug-in step includes:

- Heavy duty 440V harmonic filtration rated capacitors with discharge resistors

- Fusegear and capacitor switching rated contactor T2
- Anti-Harmonic reactor

ENERGY SAVING INSTALLATIONS - COMMERCIAL & DOMESTIC

Passive Power Factor Correction

Power Factor Correction (PFC) is a technique of counteracting the undesirable
effects of electric loads that create a power factor less than one. This range of
passive (PFC) units can save 10%-20% of energy consumption.

Code Description Dimensions
ES100 Single Phase (2000kWh pm) 125 x 85 x 60

ES100 ES300 Three-Phase (6200kWh pm) 190 x 140 x 70D
ES300
ES3001 Three-Phase (10 000kWh pm) 240 x 190 x 90D

ES3002 Three-Phase (15 000kWh pm) 240 x 190 x 90D

Features Technical Info The three-phase energy saver can be
wired either at the DB or the incoming
• Prolongs life of appliances • Single-Phase voltage: 220-240VAC 50Hz Eskom box.
• Stabilise electrical current • Three-Phase voltage: 380-420VAC Note: As long as the black is connected
• Available in single and three-phase • Operating temperature: 60˚C (max.) to neutral, it does not matter which of
• Suitable for home, shops, offices, the other wires connect to which phase.
CAPACITORS & PFCs
restaurants, etc.

Combination Geyser / Power Factor Protection & Surge Protection Technical Info

Combination units consist of both geyser controller and passive power factor • Single-Phase voltage: 220-240VAC 50Hz
(energy saving). These are parallel connection types, for single and three • Three-Phase voltage: 380-420VAC
phase units, some available fitted with surge protection. • Surge Protection: 65kA

Code Description Dimensions
ES100-GC 170 x 200 x 85mm
Single phase power + Geyser controller

ES100-GC-SS Single phase power + Geyser + Surge protection 170 x 200 x 85mm

ES100-2GC-SS Single phase power + 2 x Geyser + Surge protection 170 x 200 x 85mm Red (or Brown) White (or Brown) wire to
ES300-GC Wire to Red Phase Secondary side of Geyser
ES300-GC-SS C/B (or Isolator)
ES300-2GC-SS Three phase power + Geyser controller 210 x 215 x 100mm White (or green/ Yellow)
Wire to Phase Red Wire to Geyser

Three phase power + Geyser + Surge protection (3ph+N) 210 x 215 x 100mm Blue wire to Ditto for other controllers
Three phase power + 2 x Geyser + Surge protection (3ph+N) 210 x 215 x 100mm Blue phase

Black Wire
to Neutral

265 T

THERMOSTATS

Code Contact Rating Control

Clima – Series 6-30˚C Surface mount

CLIMA ML 16A Heating only

MLI ML CLIMA MLI 10A Heating only + on/off switch
MLW
CLIMA MLW 10A Heating – Off – Cooling

CLIMA FC 10A Heating – Off – Cooling, Speed 1/Speed 2

CLIMA FC

Rio – Series 6-30˚C Surface mount

VN650800 15A Heating only
Heating/Cooling + on/off switch
VN652400 10A Heating/Cooling + on/off switch + on lamp

VN653200 10A

Room Thermostats 10-30°C

BEL-B1 BEL4118-A2 A7700 A7700 16A Heating only 10 - 30˚C with on/off 20A isolator mounting into stan-
BEL-B2 BEL4118-B1 BEL4118-E1 dard 4 x 2 box. Max switching 3600W
16A Heating only 10-30°C with on/off switch mounting into
BEL4118-A2 75 x 75mm box
16A
Heating only with on/off switch mounting into 75 x 75mm box c/w
BEL4118-B1 remote sensor with 3m cable, adj between 10 - 50˚C.

BEL4118-E1 16A LCD Electronic Thermostat. heating only 10-30˚C with 7 day timer
programmable. 6 times, 6 temperature settings per day. Remote

sensor with 3m cable

BEL-B1 – 75 x 75 x 32(D)mm Flush Mount Wall Box
BEL-B2 – 86 x 86 x 32(D)mm Surface Mount Box

Thermostats for Air Conditioning Systems (Surface Mount)

Temperature Control 10-30˚C

BEL-3538/03A 5A 3 Speed Fan Switch with 10-30°C Temp. Control and on/off switch
BEL-3538/03LA 5A As BEL-3538/03A with Digital Temp. Display

BEL-3538/03A BEL-3538/03LA

Digital Room Thermostats

NEO-ML 7A Heating only for surface mounting. Temperature regulation 5 - 35˚C

DECO-TERMO 8A Heating and cooling, control with two programmable temperature
levels, mounts into 75 x 75mm box.
Temperature range 0-40˚C TEMPERATURE CONTROLS

DECO-TERMO NEO-ML Thermostats - c/w Timing Functions
NEO ERA
ERA 5A Heating and cooling with comfort and saving settings. Daily timing.
DECO CRONO NEO 5A Temperature range 10 - 40˚C.
DECO-CRONO 8A Heating and cooling with 2 temperature settings and anti-ice setting.
Weekly timing with 8 programs . Surface mounting. Temperature
range 0 - 50˚C
Heating and cooling with 2 temperature settings and anti-ice setting.
Weekly timing with 8 programs. Mounts into 75 x 75mm box.
Temperature range 0 - 40˚C.

TC 266

PID TEMPERATURE CONTROLLERS

Universal 4 Digit Temperature Controller – Dual Indication (full PID controller)

Control Relay & Alarm Relay TZN4S-14R TZ4ST-14R TZN4M-14R TZ4L-14R TZ4H-14R TZ4W-14R
4-20mA output & Alarm Relay TZN4S-14C TZ4ST-14C TZN4M-14C TZ4L-14C
Control Relay + 2 Alarm Relays TZN4ST-24R TZN4M-24R – TZ4H-14C TZ4W-14C
Size (H x W) - 48 x 48mm
48 x 48mm 72 x 72mm / 96 x 96mm – TZ4W-24R

96 x 48mm 48 x 96mm

Features • S V2 input for oven door interlock Specifications
• Indicating accuracy of ±0.3% ( F - S)
• 2 x 7 digit LED displays: • D ual PID function selectable fast response • M ulti-volt Supply: 100 to 240VAC
PV (Process Value) RED • C onsumption: 5VA
SV1 (Set Point Value) GREEN PID action (PIDF) or slow response PID action (PIDS) • C ontrol Relay output: C/O 3A @ 250VAC
• Control: ON/OFF, P, PI, PD, PIDF, PIDS control • S ampling time: 250ms
• M easure range: multi-range and pre-scalable
• Input types: T C (J, K, R, S, T,...)

RTD (PT100...)
0-10V, 1-5V, 4-20mA

Connection Diagram for TZN4S Connection Diagram for TZN4M Connection Diagram for TZ4H

Control
O/P ‘C’

TEMPERATURE INDICATORS

Indicator Indicator 5 Sensor Input Indicator Indicator Indicator

TEMPERATURE CONTROLS Code: PT100 T3NI-400P T4YI-400P T4WM-400P MTR10-599P SG-781*P SG-681*P
Code: J – T4YI-500J T4WM-500J MTR10-999J SG-781*J SG-681*J
Code: K – T4YI-1200K T4WM-1200K MTR10-999K SG-781*K SG-681*K
Size 36 x 72mm 48 x 96mm 72 x 72mm 96 x 96mm
Supply Volts 24 x 48mm 100-240VAC 110-240VAC 34 x 76mm
12-24VDC 230VAC 110-230VAC
Temperature Range – – *Add Temp Range to code:
– – 100, 200, 400°C
267 TC

DIGITAL TEMPERATURE CONTROLLERS

Accuracy ±0.25%
Read Rate 3/sec

Code ESM4410-*-230 ESM4420-** ESM-4430-** ESM-7730-** ESM4435-**

Voltage 230VAC 230VAC, 115VAC, 24VAC/DC 100-240VAC / 24VAC/DC 100-240VAC / 24VAC/DC 100-240VAC / 24VAC/DC
On/Off On/Off, P, PI, PD, PID On/Off, P, PI, PD, PID
Control Method On/Off, P, PI, PD, PID On/Off, P, PI, PD, PID Auto / Manual Auto / Manual
PID Tuning ― 4 digit 10mm (red) 4 digit 10mm (red)
Process Display 3 digit 10mm (red) Auto / Manual Auto / Manual 4 digit 8mm (Green) 4 digit 8mm (Green)
Set Value Display Display during set-up
Sensor Input * Select when ordering 4 digit 10mm (red) 4 digit 10mm (red) J, K, R, S, T,B,E,N, PT100 J, K, R, S, T,B,E,N, PT100
Process Inputs N/A 0-50mV/5V/10V, 0/4-20mA
N/A 4 digit 8mm (Green) 4 digit 8mm (Green) 0-50mV/5V/10V, 0/4-20mA
Process Supply ― 0-50mV/5V/10V, 0/4-20mA
Heating/Cooling √ J, K, R, S, T, PT100 J, K, R, S, T,B,E,N, PT100 √ √
Programmable Alarms ― √ √
N/O Relay 7A@250VAC N/A N/A N/O Relay 5A@250VAC
Output 1 ― N/O Relay 5A@250VAC N/O Relay 5A@250VAC
― ― 0-50mV/5V/10V, 0/4-20mA N/O Relay 5A@250VAC 0/4-20mA / 0/2-10V
Output 2 48x48x116mm SSR (20mA@12VDC) 48x48x116mm
Output 3 √√
3 readings/sec 72x72x87.5mm 3 readings/sec
Size √√ 3 readings/sec
Read Rate
N/O Relay 5A@250VAC N/O Relay 5A@250VAC

N/O Relay 5A@250VAC N/O Relay 5A@250VAC

SSR (20mA@12VDC) SSR (20mA@12VDC)

48x48x116mm 48x48x116mm

3 readings/sec 3 readings/sec

* Add to code J = J-Type, K = K-Type, P = PT100, N = NTC
** Add to code 230 (230VAC), 240 (100-240VAC), 115 (115VAC), 24 (24VAC/DC)
Features

• User friendly installation and operation. • Adjustable hysteresis for greater flexibility

• Universal Input TC, RTD, mVDC, VDC,mADC (excl ESM4410) • Text based Function menu for ease of set-up

• Automatic or manual PID tuning for greater control • Dual Display of process temperature and set value (excludes ESM4410)

• Adjustable PID cycle time for greater control • Adjustable On and Off delay on alarms

SCR HEATER ELEMENT REGULATORS

Voltage Control for Heaters Single Phase (230V)

Code Current KW Ultra fast Code Current KW Ultra fast
Fuse Fuse
SG-027 27A 6 30A SG-100 100A 22 100A
SG-057 57A 12.5 60A SG-132 132A 29.3 160A
SG-162 162A 36 160A

Three Phase (400V)

Code Load KW Ultra fast Code Load KW Ultra fast
Current Fuse Current Fuse
16.5 SG-3100 100A 66 100A
SG-325 25A 33 25A SG-3130 130A 86 160A TEMPERATURE CONTROLS
SG-350 50A 49 50A SG-3160 160A 105 160A
SG-375 75A
75A

Benefits Specifications Output Voltage: 0-100%
Input Signal: 4-20mA, 0-20mA, 1-5VDC. 0-5VDC Constant- Voltage Characteristics: Output accuracy 1%
• Small size, saving space Control System: Phase control Ambient Temperature: -10/50°C Humidity 90% RH below
• H igh accuracy and fast response Insulation Resistance: 500VDC (10g ohms) VR1: Min V output Ads.
• Eliminates contactor noise VR2: Max V output Ads.
• Extends heater life Connection Diagram
• High efficiency, no maintenance­
• M aintains stable process

temperature­

TC 268

TEMPERATURE CONTROLLERS

ON/OFF Analogue Setting Analog Setting Thumbwheel Setting
Control Analogue Setting & Deviation & Full Scale Display & Digital Display

Display

Size 96 x 48 – – – – – KE-861*

Size 72 x 72 KE-714* KE-724* – KE-742* KE-771* –

Size 96 x 96 KE-612* KE-622* KE-632* KE-642* KE-671* KE-861/A*

72 xW7i2th/ 9a6laxrm96 – – – – KE-771/A*/KE-671/A*
Range & Probe Digital
*Add temperature 100, 200, 400 or 600°C and Probe type PT100., J or K e.g. KE-724 200K

Higher Range ‘K’ – – 800 & 1200°C –

Technical Specifications Connection Diagram

Supply: 110/220VAC Output: Relay 1C/O
Input: Thermocouple 5A@250V
K, J and PT100 Hysteresis: 2,5% full scale
Accuracy: 1% of full scale Alarm: 10% of full scale
Control: On/Off action

Digital 1 Set Point Digital 2 Set Point Thumbwheel 1 Set Point Analogue 1 Set Point

ON/OFF
Control

Size 72 x 72mm 72 x 72mm 48 x 48mm 48 x 48mm 34 x 76mm
Probe PT100 TR-48*P *100, 200, 400°C MTR11-150PTC*
Probe J & K VM6251 -99° to 999°C VM6269 -99° to 999°C TP-48*P *100, 200, 400°C TR-48*J *100, 200, 400°C
TR-48*K *100, 200, 400°C –
VM6392 -99° to 999°C VM6400 -99° to 999°C TP-48*J *200, 400°C
Reversed 8 pin P3G-08 –
Technical Specifications TP-48*K *200, 400°C
• Supply: 230VAC
Supply: 24 or 230VAC • D irect/Reverse PWM & All supplied complete with * C/W Probe
Input: Thermocouple K, J Neutral zone operation Range: 50-150°C
& PT100 Y-50 mounting bracket Spare Probe: PTC150
Accuracy: 1% of full scale Specifications:
Output: Relay C/O 8A@250V Connection Diagram Supply voltage
110-240VAC
TEMPERATURE CONTROLS • Min/Max Alarms Hysteresis 2,5% full scale
• D ifferential or Hysteresis Relay output: 1 C/O @ 2A
p­ rogrammable 250VAC
Panel-mount or 8 pin

plug-in.

When using 2-wire PT100 Probe, short circuit terminals 4 and 5 Connection Diagram
Transparent cover for 72 x 72 Adaptor for 72 x 72 to 96 x 96

VJ4482 VJ4458

Supply
Volts

269 IP54 TC
For blind temperature controllers, see pages 6 & 24.

TEMPERATURE PROBES

Thermocouples
NOTE: Wire Colours - J: Red & Blue, K: Red & Green, PT100: 2 x White, 1 x Red



PVC Cable

Probe size 100mm x 5.0 Ø
Cable: 1.5m

Steel Cable

Probe size 100mm x 5.0 Ø Thread size 1/4” or 1/2” Steel Braided Cable PVC Coated Probe:
Cable: 1.5m Cable: 1.5m 1/2” Thread
150mm x 5.0 Ø
Probe Thermo- Temp Cable Screw Temp Code Description Com­
Type couple Range Type Type Range Head Large pression
Type Code Type Head Clamp
Code Code

PT100 TC-P 100D 100°C PVC TC-P/S* 400°C TC-P2 CABLE 200°C PVC coated Grey KSE-P KEN-P 1/2” Brass
TC-P4 CABLE 400°C Steel braided CC-02B
Std 1/4” thread 200°C PVC KSE-J KEN-J
PT100 TC-P 200D* 400°C Steel KSE-K KEN-K 1/4” Brass
PT100 TC-P STEEL CC-04B
400°C Steel TC-J/S* 400°C TC-J CABLE 400°C Steel braided
Std ¼” thread 400°C Steel TC-K/S* 400°C TC-K CABLE 400°C Steel braided 1/2” S/Steel
Type J TC-J* CC-02S
Type K TC-K* *Specify 1/4” or 1/2”
1/4” S/Steel
*Specify 1/4” or 1/2” CC-04S

Head Mount Temperature Transmitter - Programmable & Loop Powered Thermocouple Connectors

Code T121

Description Programmable using Programming Kit S117P-1 (see page 258)
Input: PT100, Ni100, PT500, PT1000, J, K, R, S, T, B, E, N thermocouples
Power Supply: 7 - 30 VDC. Current Output: 4/20 or 20/4mA (2 wire) Female Male
Resolution: 2μA (>13bit). Response Time: >1s
Over range fault output: 102.5 - 105% full scale FPL-PT100 MPL-PT100
Connection by spring terminals: (wire size 0.2 - 0.25mm² ) FPL-J MPL-J
Size: 20mm x 43.7mmØ FPL-K MPL-K

Temperature Transmitter (2 wire) - Fits into Head Type KEN-P/J/K

Code Temperature Range Specifications
Output Signal: 4 - 20mA DC
TRT-PT100* 50, 100,150, 200, 400°C Power Supply: 10 - 36VDC
Accuracy: ±0.15% F.S. (PT100)
TRT-J* 100,150, 200, 400, 600°C ±0.5% F.S. (J & K)v

Installation TRT-K* 100,150, 200, 400, 600, 1000, 1200°C
example
*Add Temperature range to code

TEMPERATURE SWITCHES

Electronic Temperature Switch Mechanical Temperature High Performance Temperature Switch TEMPERATURE CONTROLS
- with fixed Switching Point IP66 - with Power relay, with fixed Switching Point IP67
- with programmable LED Display IP65
• 12 - 24VDC, 48VAC • 24VDC
• 12 - 30VDC • 4A Switch rating • 30A Switch rating

• 100mA
• M12 4-pin Plug

Probe Size: Probe Size: Cable:
Ø6 x 0.75mm (up to 40 Bar) Ø10mm (up to 100 Bar) 1.5m open leads
Length: 25mm Length: 28mm 1/2" thread
SL6410* S6410*

Code Output Temp Code Output Temp Code Output Temp
Range Range Range

TC5400-* 2 x PNP -50 to 125°C SL6410-*-** NO/NC + 40 to 200°C S6300-* NO - 20 to 120°C
TC5410-* 1 x PNP & 1 x 4-20mA -50 to 200°C S6410-*-** NO/NC + 40 to 200°C - - -

*Specify 1/4" or 1/2" thread **Add Temperature: 040, 060, 080, 100, 120, *Add Temperature: 040, 050, 060, 070, 080,
140, 160,180, 200°C 090, 100, 110°C

e.g. SL6410-1/4-040 e.g. S6300-040

*Specify 1/4" or 1/2" thread

TC 270

TEMPERATURE CONTROLLERS IP64

Size: 76 x 36mm
Cutout: 71 x 29mm
Display: 3 Digit + Sign

Code KLT11BB-J (J Probe) KLT11D KLT11D2 KLT12D KLT22D KLT32
KLT11BB-K (K Probe)
Range -50 to 150°C
J = 0 to 700°C
Supply K = 0 to 999°C 230VAC, 110VAC, 24VAC/DC or 12VAC/DC to be specified
Probe (excluded)
J or K Probe PTC or NTC PTC or NTC PTC20±2°C / PTC05±0.5°C
Output relay Program Selectable Program Selectable Program Selectable
N/O 16A Control, C/O 5A
Function 1 Relay C/O 16A N/O 20A 16A N/O Control Defrost, N/O 8A Fan
Alarm C/O 16A N/ O 8A C/O Defrost
Communication Control Control for compressor,
Card Output (KL-KEY) 2 Alarm set points Control C ontrol Control & fan & defrost
Connection Diagram Defrost –
Yes
– – – –

Yes Yes Yes Yes

KLT11D KLT12D 16A

KLT11D2 KLT22D 16A 8A

Specifications • Cooling or heating • Cooling or heating • 1 or 2 Probe selectable • 1 or 2 Probe selectable
• Inside alarm buzzer • High & low value set point • Designed for refrigeration • D esigned for refrigeration
• Accuracy 1% • A ble to program 23 • A ble to program 52

­different parameters, i.e. ­different parameters, i.e.

hysteresis, defrost time hysteresis, defrost time

Temperature Indicators Accessories (Probes c/w 1.5m cable)

Code TKTZ DT-101S Code Description
Range -50 to +99°C
TEMPERATURE CONTROLS Supply 230VAC or 115VAC -40 to +70°C PTC20 PVC Cable. Accuracy ± 2°. Range -50°C / 105°C
Probe PTC20 (included) Battery included PTC05 PVC Cable. Accuracy ± 0.5°. Range -50°C / 105°C
Size 62(W)x29mm(H) 1.1m cable (included) NTC20 PVC Cable. Accuracy ± 1°. Range -50°C / 105°C
48(W)x28mm(H)
KLRS485 KLGATEWAY
Communication Accessories - for KLT Range

Code Description
KLRS485 Isolated RS485 Communication Module for KLT Range Controllers
KLRTRL Interface Cable between Controller & KLRS485
KLUSB485 RS485 - USB Interface between PC and KLT Devices
KLGATEWAY RS485 - Ethernet Interface between KLT Controller Installation and
KLNetCenter through Lan or Internet

KLUSB485

271 TC

HUMIDITY & TEMPERATURE CONTROLS

Humidity Sensors Combined Humidity & Temperature Sensors

IP30 1.5m cable length 1.5m cable length

Code VN8736 KLSH03 TH-102W TH-101D TH-103S
Supply Voltage
Range 9-30VDC / 12-24VAC 5VDC 12/24VDC 12/24VDC 12/24VDC
20-90% RH 10-90% RH 0-100°C / 0-100%RH 0-100°C / 0-100%RH 0-100°C / 0-100%RH
Output 4-20mA or 0.1-1V 1 to 3VDC 4-20mA (2-wire) 4-20mA (2-wire) 4-20mA (2-wire)

HUMIDITY CONTROLLERS TEMPERATURE & HUMIDITY CONTROLLER

IP65 Features

Code KLTH43 • R ed display for
temperature and green
Code DPM-RH-* KLH11RH Size 134 x 105mm ­display for humidity
Cutout Size 130.5 x 100.5mm • T emperature control can
76 x 36 x 60D mm Supply 230VAC be ON/OFF, n­ eutral zone
Size 72 x 72 mm 110VAC or 230VAC Temp. Range -50°C to 150°C (0.5%) or refrigeration
Supply 110VAC or 230VAC 0-1V, 1-3V KLSH03, Hum. Range 0-100% RH (5%) • Second temperature
Input* 4-20mA (VN8736) / 1-3V Temp 2 x PTC05 ±0.5% or PTC20 ±2% probe can be used for
0-100% RH Probes defrosting control
Range 0-100% RH • Humidity control can be
Differential or Hysteresis (excluded) Humidity 1 x (0-1V) / (0-3V) 4-20mA probe ON/OFF or neutral zone.
Settings Hysteresis Adj. Relay C/O 8A 4 SPDT Relays 8A @ 250VAC • H umidity probe (0-1V) /
Output Relay C/O 8A Outputs (0-3V) / (4-20mA) select­
able by programme
Display Red for temperature; Green for humidity • Resolution:
Temp: 0.1°C
Humidity: 1%

Indicators Indoor In/Outdoor Wireless Weather Centre
Thermometer Thermometer

Code CTH-608 CTH-609 WS1170

Wall or Table mount (back stand built-in) • Display: in °C or °F
• Temperature Ranges:
Memory store and recall of max/min temp. and humidity
Indoor:
Clock: 12/24hr Format, Alarm, Calendar Function 0°C to 60°C (built in)
Outdoor:
CTH-608 Battery: 1 x AAA size (included) -40°C to 65°C (wireless x1)
CTH-609 • H umidity Range:
LCD Size 80 x 70mm 1%RH-99%RH
• A ccuracy: ±1°C
Temperature Display in "C" or "F" selectable Battery: 3 x 1.5V AA (excluded)
Sensor: 2 x 1.5V AAA (excluded)
WS1170 Range: -10ºC to 50ºC ±1ºC
Indoor: -14ºF to 122ºF±1.8ºF
Range: -50ºC to 70ºC ±1ºC Outdoor: -50ºC to 70ºC ±1ºC TEMPERATURE CONTROLS
-58ºF to 158ºF±1.8ºF

- -58ºF to 158ºF±1.8ºF
Humidity: 10% to 99%RH±1% Frost Warning: -1 to 4ºC
Humidity: 20% to 99%RH±1%

Temperature & Humidity Temperature Only Indicator Glass Temperature Thermometer
Indicator Indicator

TH-920 TH-922 CS-120

Size mm: 360H x 395W x 100D • 0-100°C Temp • 0-120°C/20-180°F
• 0-100% Humidity • 1/2” BSP thread
• Length: 150mm
• Supply 85-265VAC
• Sensor TH-101/2/3 • Size mm: 200H x 395W x 100D
or VN8736 (see above) • 0-100°C Temp
• Input: 4-20mA • Supply 85-265VAC
• Digit size mm: 100H x 60W • Input: TC-P 100D

TC 272

DIGITAL DEFROSTING & TEMPERATURE CONTROLS

Temperature Controllers for Walk-in Freezers and Cooling Displays
Size: 71 x 28 x 71mm
Cut Out: 71 x 29mm
Display: 3 Digit/Sign

Code TC-900RI-CL TC-900RI-P TC-920RI TC-940RI-P
Range -50 to +75˚C/ -58 to 167 F
Supply -50 to +75˚C/ -58 to 167 F -50 to +75˚C/ -58 to 167 F -50 to +75˚C/ -58 to 167 F
Probe 115 or 230VAC ±10% 90-264VAC 115 or 230VAC ±10% 115 or 230VAC ±10%
2 x SB19 2 x SB19 3 x SB19 2 x SB19
Relay Output NTC Sensor (Inc.) NTC Sensor (Inc.) NTC Sensor (2 Inc.) NTC Sensor (Inc.)
N/O 5A Refr N/O 16A Comp N/O 5A Refr
Coms N/O 5A Fans N/O 5A Fans N/O 5A Fans N/O 16A Comp 3A N/O Alrm
Function N/O 5A Defrost N/O 8A Defrost N/O 3A Defrost N/O 5A Defrost
Connection diagram Yes No N/O 5A Fans
Control/ Ref/ Defrost No Control/ Ref/ Defrost Yes
Control/ Ref/ Defrost
Control/ Ref/ Defrost

Remote management

software R/ deaayl t&imienteclroncakl,buapttetory8 defrost
Code: SITRAD

Refrigeration Frozen

Size: 71 x 28 x 71mm Display: 2
Cut Out: 71 x 28mm Digit/Sign
Display: 3 Digit/Sign

Code MT-512RI MT-512RI-LOG TC-900RG2
Range -50 to +75˚C/ -58 to 167 F
Supply 0 to 50˚C/ 32 to 122˚F -50 to +75˚C/ -58 to 167 F
Probe 115 or 230VAC ±10% 115 or 230VAC ±10% 115 or 230VAC ±10%
1 x SB19 2 x SB19
Relay Output 1 x SB19
NTC Sensor (Inc) NTC Sensor (Inc)
Coms NTC Sensor (Inc) N/O 16(8)A/ 250VAC 1HP N/O 16(8)A/ 250VAC 1HP
Function N/O 16(8)A/ 250VAC 1HP
Connection diagram N/C 8A/ 250VAC N/C 8A/ 250VAC
N/C 8A/ 250VAC Yes No
Remote manage- Yes
ment software Refrigerate Control/ Comp/ Defrost/ FANS
Code: SITRAD Refrigerate/Display coolers
Temperature & Humidity
Size: 71 x 28 x 71mm With a timer for cooling & defrost times
Cut Out: 71 x 28mm Temperature Controls
Display: 3 Digit/Sign

TEMPERATURE CONTROLS Code MT-516RVTI MT-518RI MT-530SUPER
Range -50 to 105˚C
Supply -50 to 105˚C -50 to 105˚C
Probe 115 or 230VAC ±10% 115 or 230VAC ±10% 115 or 230VAC ±10%
1 x SB56 NTC Temperature and
Relay Output 1 x SB19 1 x SB19
NTC Sensor (Inc) NTC Sensor (Inc) Humidity Sensor (Inc)
Coms N/O 8A/ 250VAC 1HP N/O 8A/ 250VAC 1HP 3 x N/O 5A @ 250VAC
Function N/O 8A/ 250VAC N/O 8A/ 250VAC
Connection diagram Temp/Humidity/Aux
Yes No Yes
Remote manage- Temperature Controller with over/under voltage protection Temperature Controller/Cooling or Heating
ment software Temperature/ Humidity Controller
Code: SITRAD For milk cooling Includes For air conditioning
For data centres & genl. aircon
273 Cyclic
Timer

0-999min

TC

POWER MONITORS TIMERS TEMPERATURE DISPLAY

Instrument for Scheduler with real- The big therm is a
measuring and time clock that digital thermometer.
monitoring the allows configuring The dimensions and
major parameters up to four events design of this
regarding energy for each weekday, instrument allow the
quality on three- through the defini- temperature for
phase electrical tion of start and end long-distance
installations times for each one. visualization.

Code PHASE LOG PLUS PROGS-1 TIC-17G
Supply
Control Range 85 to 265VAC (50/60Hz) 85 to 265VAC (50/60Hz) 110 or 220VAC (50/60Hz)
Current 90-500VAC 24hr, 365 days -55 - 90˚C
Dimensons
Operation Temp 5A/ 250VAC 1/8hp 10A (resistive load) NTC with cable 1,5m
Communication 71 x 28 x 71mm 70 x 28 x 60mm 90 x 44 x 27mm
Application 0-60˚C 0 - 50˚C
0-50˚C No No
Features yes, RS-485
Electrical panels Ovens, injection machine, defrost control Refrigerating equipment greenhouse, ovens,
Other multi-phase equipment climatized rooms.

Over/ Under voltage (Adjustable) Remote Management Software
Phase Failure & Phase Sequence
Code SITRAD-*
Data Logger Per Phase
More than just automation, sitrad innovates in the management of cooling, heating, air conditioning, and solar heating
systems by means of its most distinguishing feature: connectivity. The user can continuously evaluate, configure and
store data on temperature, humidity and pressure, among others

• *Local: must be installed in the computer to which the instruments are connected via interface
• *Remote: must be installed in the computer that will remotely manage the installation, via Internet
• *Mobile: manages facilities via cell phone, communicating with the local module
With mobile, the user has another option for remote management. Without using a computer, it provides even easier
remote installation management. It is the connectivity allowing to take over the control, anytime, anywhere

DIGITAL DEFROSTING & TEMPERATURE CONTROLS

Differential Temperature Controllers for Pumped Solar Heating Systems

Code ANASOL MICROSOL RI *V6 MICROSOL II *PLUS
Features
Economy range of differential Differential thermostat for automation of Differential temperature controller for
Supply temperature controller used to control pumped solar heating systems. automation of pumped solar heating
the pump of solar water heating With Anti-Freeze and Overheating systems.With Anti-Freeze, Overheating
applications. With Anti-Freeze function. functions. and solar back-up functions.
Supplied with 2 colour coded sensors. Supplied with 2 colour coded sensors. Supplied with 3 colour coded sensors.

115-250VAC 115-250VAC or 115-250VAC or
* Add "L" for 12-24VAC/DC * Add "L" for 12-24VAC/DC
Control Range -50 to 105°C
Load Current 16A@ 250VAC 1HP -50 to 105°C -50 to 105°C
Operating Temp 16A@ 250VAC 1HP 16A@ 250VAC 1HP
0° to 50°C
No. of Sensors IP's 2 Colour Coded 0° to 50°C 0° to 50°C
Dimension 100 x 72.8 x 36.8mm 3 Colour Coded 3 Colour Coded
Connection Diagram 71 x 28 x 71mm 71 x 28 x 71mm
115V
230V

Sensor 1
Black Cable

Sensor 2
Grey Cable
Sensor 3
Black Cable

COMMON
NO
NC

Serial Communication
RS-485
Sensor 1
Black Cable
Sensor 2
Grey Cable
Sensor 3
COMMON
PUMP
ACDC1
ACDC2

TEMPERATURE CONTROLS
115V 230V Load 230V 115V
Power
Sensor S1 - Black Silicone Pump Power Load Supply
Panels or Solar Collector Supply Supply
Load Supply To the terminal of distribution box
Sensor S2 - Grey PVC
Reservoir/Pool Power Supply
5-6 / 115V
5-7 / 230V

TC 274

RADIO REMOTE CRANE & MACHINE CONTROL IP65

8 Button Hand Held Controllers 10 Button Hand Held Controllers

With Display

Code 946091-400 949190-400 946093-400 949192-400 947704-400
Functions 10 x 2 Stage Buttons
8 x 2 Stage Buttons 8 x 2 Stage Buttons 10 x 2 Stage Buttons 10 x 2 Stage Buttons Quick Stop Switch
Markings Quick Stop Switch
Display Quick Stop Switch Quick Stop Switch Quick Stop Switch Din Symbols
Size Din Symbols LCD 02 x 64 Pixels
Weight ― Symbols 1-8 Din Symbols Symbols 1-10
Features
―― ―

243 x 77 x 41mm

480grams

• Output: 10mW @ 433-434MHz • Baud Rate: 9600 • Internal Antenna

• Battery: 3.7V / 1.8Ah • 13hr Operating Time

9 Button Hand Held Controllers Jupiter Joy-Stick Controllers
With Display
With Display With Display

Code 947823-400 947824-400 949767-401 949768-401 949769-401
Functions
9 x 2 Stage Buttons 9 x 2 Stage Buttons 3 Directions 2 Speed 3 Directions 2 Speed 3 Directions 2 Speed
Markings
Display 1 x Rotary Switch (4 Pos) 1 x Rotary Switch 2 Extra controls 2 Extra controls 5 Extra controls
Size
Weight Quick Stop Switch Quick Stop Switch
Features
DIN Symbols DIN Symbols DIN Symbols DIN Symbols DIN Symbols

― LCD Display 102 x 64px ― LCD Display 102 x 64px LCD Display 102 x 64px

243 x 77 x 41mm 260 x 165 x 150mm

480grams 520grams

• Output: 10mW @ 433-434MHz • Baud Rate: 9600 • Internal Antenna

• Battery: 3.7V / 1.8Ah • 13hr Operating Time

Jupiter Receiver - RX160 Accessories for Remotus - Hand Held

CRANE & VEHICLE CONTROLS Code 948470-800 Code 934158-000 935408-001 934157-001
No Of Outputs Code Belt Clip Vehicle Bracket Protective Bag
16: 4 C/O & 12 Open Contacts of
No Of Inputs which 6 are safety relays Accessories for Jupiter
1 Analogue 0(4)-20mA or 0/2-10V
Digital Inputs 1 Serial Input RS422/RS485 944204-000 947108-000
2 Opto Isolated for 24/48V AC/DC, Shoulder Strap Harness
Radio Freq. 115VAC or 230VAC 50/60 Hz
Mem Capacity 433-434 MHz
Protection 500 Transmitters
Casing IP67
Outputs For E/Stop Flame Retardent Plastic (UL 94 5VA)
Antenna 2 Safety Relays: 2 C/O Contacts
Size Internal
Weight 277 x 217 x 115mm
Supply Voltage 1.5kg
Consumption 24-230VAC/24VDC
Operating Temp MAX 12 VA
-25 to +55°C

279 For customised solutions contact ACDC Dynamics and Q
refer to shortform catalogue for complete range.

AIR LINE FILTERS & REGULATORS

Type Filter Regulator Filter/ TC Series Treatment TC Series Treatment Triplet
Regulator Oil Sprayer Dual Regulator & Air Filter/Regulator/Lubricator

Lubricator

Code 3/4” TF4000-06 TR4000-06 TW4000-06 TL4000-06 TC4010-06 TC4000-06
TW5000-10 TC5000-10
Code 1” TF5000-10 TR5000-10 TL5000-10 TC5010-10
TAD
Specifications Auto Drain Valve UW Series

• Filtration: 5µm Code 3/8” TAD402-03
• Applicable Pressure Range: 0-1.0MPa Code 1/2” TAD402-04
• Applicable Temperature: 0-60°C
• Gauge Port Size: G1/4
• Material (Body): Aluminium Alloy Die-cast
(Bowl): Polycarbonate (PC)

SOLENOID VALVES

US Series

USSC

USC US-10 US-25 UW-15 UW-25
UW-25 *
Code US-10 * US-15 * US-20 * US-25 * UW-15 * UW-20 *
Spare Coil Code
Spare Solenoid USC * UWC *
c/w Coil
Material of body USSC * UWSC *
Operating method
Pipe size Brass
Nominal diameter (mm)
Applicable fluid P lunger Pilot Film Pilot LIMIT & PRESSURE SWITCHES & SENSORS
Pressure range
Applicable temperature ZG3/8” ZG1/2” ZG3/4” ZG1” ZG1/2” ZG3/4” ZG1”
Operating voltage range
Minimum activating time 17 17 17 20 20 20 25

PS-02A Air, Water, Oil (50CST below) & Steam Air, Water, Oil (50CST below)

0.05 – 1.5Mpa 0 – 0.8Mpa

-5 to 185°C -5 to 99°C

± 10%

0.05S

*Add Voltage to Code: 12VDC, 24VDC, 24VAC, 110VAC, 230VAC

Pressure Switches

Pressure (Bar) Contact Rating Pipe Thread Code
Min. Max. (NPT)

PS-02B 1.4 2.8 2 Pole 20A N/C 1/4” PS-02A 2.8
2.1 3.5 2 Pole 20A N/C 1/4” PS-02A 3.5
2.8 4.3 2 Pole 20A N/C 1/4” PS-02A 4.3
3.5 5.6 2 Pole 20A N/C 1/4” PS-02B 5.6
4.9 7.2 2 Pole 20A N/C 1/4” PS-02B 7.2

CON 280

PROCESS GAUGES

Type Stainless Steel Case Robust Liquid Filled Economic

Code PBB- * - ** - *** - **** - ***** PBG- * - ** - *** - **** - ***** PBN- * - ** - *** - **** - *****

Connection This gauge is ideally suited to most For heavy duty services where vibration or For non-corrosive liquids and gases on light
A-Bottom Connection industrial applications where high accuracy shock of medium would cause excessive wear duty service in more corrosive environments.
D-Rear Connection and durability is required. Gauges are on a dry gauge or corrosive ambient Applications include coastal application for
available with either brass/bronze internals, conditions prevail. Applications include valve positioner and regulators, swimming
Case all stainless steel internals, or Manel hydraulic equipment, mining equipment and pool pumps and stationary irrigation systems.
Internals Bourdan tube and socket with stainless irrigation.
Range (Max) steel movement. Steel Black, Powder Coated
Temperature 304 SS, Crimped Bezel Brass
Accuracy Brush finish 304 SS, Bayonet Bezel Brass 6000 kPa
Configuration Available with either Brass/Bronze, or SS 6000 kPa -25℃ to 60℃
-25℃ to 60℃ 1.6% @ FSD
Thread 6000 kPa 1.6% @ FSD

Code Fitting -25℃ to 60℃
02 1/4 NPT 100Ø 1% @ FSD / 63Ø 1.6% @FSD
04 1/2 NPT
12 1/4 BSP Conn. A + D A+D Conn. A + D A+D Conn. A
14 1/2 BSP

Add to code

* Connection A (Bottom) & D (Rear) A (Bottom) & D (Rear) A (Bottom) only

** Add size (mm) 63 100 63 only 54 only

*** System material BB&SS BB BB

**** Thread size 02, 12 02, 04, 12, 14 02, 12 02, 12

***** Add pressure 100kPA, 160kPA, 250KPA, 400kPA, 600kPA, 1000kPA, 1600kPA, 2500kPA, 4000kPA, 6000kPA. Other ranges available on request.

Process Gauges Accessories

Steam Line Piping Valve Dairy Seals Chemical Seals Flanged Seals

LIMIT & PRESSURE SWITCHES & SENSORS NW40 NW50

Code U-TYPE Code VG ISOLATE Code NW40-* NW50-* XWD4-* NFD01-*

Code PIGTAIL Isolation valves and Material Grade 316 SS 316 Stainless Steel Grade 316 SS
gauge cocks to isolate Max Pressurer
• Steam line piping should pressure from gauge. Gauge Port 40 MPA 150 Mpa 150 Mpa
be installed on all live Application
steam applications to Equipped with a facility 1/4", NPT or BSP 1/4" or 1/2", NPT or BSP 1/4" and 1/2", NPT
protect the gauge from to vent the gauge. Thread Size
the high temperatures Suitable for use with Is used in health and Is used in applications Flanged seals, one for
encountered. gases, liquids and dairy application, can be where the process fluid continuous use for safety
• Available in either "pigtail” vapours. used for pulp/paper. (medium) is corrosive or concerns.
or “U-type” configurations viscous (could even Cleanout type for easy
for installation on horizontal Material - Brass For non-corrosive liquids contain waste particles) cleaning with flushing
or vertical line respectively and gases on light duty and could clog the connections available.
Material - Steel. service in more corrosive instruments internals.
environments. *Add Thread Type to Code:
02, 04
*Add Thread Type to Code: *Add Thread Type to Code:

02, 12 02, 04,12,14

281 RHE

PRESSURE TRANSMITTERS

Standard IP67 Mini Model IP67 Pressure Transmitter IP65

DIN Plug
To be ordered
separately

EDS-ST

Code SMP136-* SMP132-* PT1X*P**R01
Pressure Range
Output * Add to code 2, 5, 10, 20, 50 or 100 bar • Accuracy to better than 0.5%FS
Supply Voltage (including linearity and repeatability)
Media Temperature 4 - 20mA • Transducer rated at 50 million cycles
Thread • Metalwork made of Type 316
Overload Pressure 12 - 30VDC Stainless Steel
Accuracy • Protected against reverse voltage
Connector ˗25°C to 85°C and overvoltage
Seal Material • Protected against noise on the supply line
Housing Material G1/4, SS316 • Wide supply range, 8 to 36VDC -
Size (Ø x L)mm allows a wide range of load resistance
Application 1.5 x Full scale • Transducer is temperature compensated
by means of laser-trimmed resistors
0.5%F.S. • Operating temperature range from
0℃ to +85℃
DIN (4 PIN) Plug • Internal Trimpots for field calibration

Fluoro Elastomer

Aluminium

Ø27mm x 97mm Ø48mm x 74mm

Machine Tools Petroleum Industry Mechanical Engineering

Environmental Chemical Industry Machine tools

Dry Gases etc Sewage plants etc Hydraulics

Hi-Temperature IP67 Flush Seal IP67 General Purpose IP68

DIN Plug SMP135-* SMP134-* LLS2.5/5 LLS10/15 GENERAL SPECIFICATIONS
To be ordered 3 bar 10 bar Output: 4 - 20mA
separately * Add to code 2, 5, 10, 20, 50 or 100 bar 4 - 20mA Excitation: 8 - 36V DC
15 - 30VDC Accuracy (BFSL):< 0.5% FS
EDS-ST 4 - 20mA 0°C - 70°C Compensated Temp. Range: 0º to 85º C LIMIT & PRESSURE SWITCHES & SENSORS
1/4" Gas Temperature error zero: < -0,02% FS / K
Code 12 - 30VDC 6 bar 20 bar Temperature error span: < -0,01% FS / K
Pressure Range 1.5%F.S. (0-70ºC)
Output ˗60°C to 200°C ˗25°C to 85°C Ingress protection: IP65
Supply Voltage Cable 5m Cable 15m Burst pressure: 2.5 x FS (except when
Media Temperature M20X1,5 G1/2 (50 & 100Bar = G3/4) Ceramic indicated)
Thread (SS316) SS314 Wetted Parts/Connection: 316 Stainless
Overload Pressure 1.5 x Full scale steel, ceramic, Nitrile (Specify media where
Accuracy Ø30mm x 54mm Nitrile is not compatible)
Connector 0.5%F.S. Pumps / Fluids WIRING CONNECTIONS
Seal Material Compressors 1 Red: + Us
Housing Material Gas 2 Black: - Vs
Size (Ø x L)mm 3 Yellow: GND
Application
* **
Code Transducer Range Code Fitting

DIN (4 PIN) Plug 0010 1 Bar 02 1/4” NPT
0040 4 Bar 04 1/2” NPT
SS316 Fluoro Elastomer 0060 6 Bar 12 1/4” BSP
Aluminium 0100 10 Bar 14 1/2” BSP
0160 16 Bar
0250 25 Bar Other options available
0400 40 Bar
Ø48mm x 219mm Ø27mm x 70mm 1000 100 Bar
4000 400 Bar
Steam / Heated process Machine tools

Thermal energy process Mechanical Engineering Other options available

Process control Hydraulics/Pneumatics PRODUCT TRANS PRESSURE FITTING
RANGE DUCER
RANGE P ** R01
PT1X
*

CON 282

ELECTRONIC AIR PRESSURE SENSORS & SWITCHES

Electronic Air Pressure Controllers

Code Code Cut-out- Cut-in- Maximum Repeat
pressure pressure pressure Accuracy
Relay Output Supply 4-20mA Supply Supply at 25°C
0.2-2 bar 0-50% of
1C/O only Output 0.5-10 bar cut-out
1-16 bar pressure
EDR-2 230VAC – – 3 bar +/-0.05 bar

– – EDI-10 12-30VAC 25 bar +/-0.1 bar

EDR-16 230VAC EDI-16 12-30VDC 25 bar +/-0.15 bar

Note: 4mA = 0 bar. 20mA = measuring range highest value

EDR & EDI • Accurate compressor and process control • User friendly menu programming
• Electronic pressure switch with integrated ­pressure sensor • Relay output – (All models) 6A @ 250VAC
• Push-on connector for air tube inlet (Festo PAN 6 x 16mm) • 0-10V Analogue output and digital LED display
• Adjustable relay set point and hysteresis
• Fail safe (EDRA only)
• Din rail mounting

Electronic Pressure Sensor

Code NPN N/O PSA-01 PSA-1
Code PNP N/O PSA-01P PSA-1P
Pressure Range 0-100.0kPa (0-1.000 Bar) 0-1000.0kPa (0-10.00 Bar)

Specifications 12V to 24VDC ± 10%. 50mA • Hysteresis: 1 digit (2 digit/psi) fixed
Max. 100mA 30VDC • R epeat Error: ± 0.2% F.S. ± 1 digit
• Power Supply: 1V-5VDC ± 2% F.S. • Response Time: Selectable 2.5ms, 5ms,
• O utput Current: kPa, kfg/cm2, bar, psi 100ms, 500ms
• Analog Output: 30x30x38.5(D)mm • Short Circuit Protection: Built-in
• Pressure Display:
• Size:

Accessories

Code Description

PS-01 Bracket for panel mount. Size of cutout 36X36mm
PS-02 Clear protection cover

2-Wire Electronic Air Pressure Transducer IP65

• Accurate process control • Service friendly plug-in electrical connection
• 2-Wire device installs directly on the machinery • Converts measured pressure to 4-20mA
• Ceramic sensor technology

Code Description Pipe Measuring Output Repeat Supply
Thread Range Accuracy

EDS-16 Transducer External G1/4" 0-16 bar 4-20mA +/-1% 11-30VDC
EDS-ST Connection plug DIN3852 Form E

EDS-16

Pressure Switch Diagrams

The co-ordinates of a cut out and cut in pressure must lie within the shaded area for the switch to be suitable for the application.

LIMIT & PRESSURE SWITCHES & SENSORS EDS-ST

283 CON

PRESSURE SWITCHES

Direct Motor Switching Ui = 500V

Cut-out Contacts Features Pipe Code Code with
Pressure (Bar) AC3 Thread Auto-Off
Min Max Diff Switch

MDR1 F or use with air, water, mineral oils, sea/salt water, butane, acetylene, carbon dioxide etc.
Medium temperature: Air -5 to +80°C. Water +70°C max. IP44
Contacts 2 N.C. Ith 20Amps, 2,2/4kW @ 240V. Bursting strength Pz >35 Bar.

MDR1/11 2.5 6.0 Adj 1ph 4.0kW For Pumps only Factory set 1.5-3 Bar 1/4" BSP MDR1/6/DIF –

2.5 11.0 2 Bar 1ph 2.2kW For Compressor only Factory set 6-8 Bar 1/4" BSP MDR1/11 MDR1/11/EA

MDR2 F or use with air, water.
Medium temperature: Water +80°C max. IP44
Contacts 2 N.C. Ith 20Amps, AC3 2.2kW @ 240V. Bursting strength Pz >35 Bar.

1.5 7.0 Adj 1ph 2.2kW 1/4" BSP MDR2/6 –
4.0 12.0 Adj 1ph 2.2kW 1/4" BSP MDR2/11 MDR2/11/EA

MDR1/11/EA MDR4 F or use with air, water.
Medium temperature: Water +80°C max. IP44
Contacts 3 N.C. Ith 20Amps, AC3 5.5kW @ 400V. Bursting strength Pz >35 Bar.

1.5 6.0 Adj 3ph 5.5kW 1/2" BSP MDR4/6 MDR4/6/EA4
4.0 11.0 Adj 3ph 5.5kW 1/2" BSP MDR4/11 MDR4/11/EA4
6.0 16.0 Adj 3ph 5.5kW 1/2" BSP MDR4/16 MDR4/16/EA4

MDR5 F or use with air, water, sea water, petrol, diesel, natural gas, butane, carbon dioxide etc.

Medium temperature: Air -5 to +80°C. Water +80°C max. IP54
Contacts 3 N.C. Ith 25Amps, AC3 5.5kW @ 400V. Bursting strength Pz >40 Bar.

MDR2/6 or /11 2.0 8.0 Adj 3ph 5.5kW 1/2" BSP MDR5/8
2.5 16.0 Adj 3ph 5.5kW 1/2" BSP MDR5/16
Fitted with Unloader Valve, Overload & Start/Stop Buttons

MDR5/8 Range: 2 .4-4.2A 1/2" BSP MDR5/16/4.2
MDR2 or 4/EA or /16 4.0-7.0A 1/2" BSP MDR5/16/7
6.1-10.3A 1/2" BSP MDR5/16/10
9.0-14.0A 1/2" BSP MDR5/16/14
11.0-18.0A 1/2" BSP MDR5/16/18

With Overload

Accessories

Spare Covers for MDR5

Description Code Unloader Valve Code

plain H5-COVER EV1S For MDR1 EV1S
with On/Off buttons H5K-COVER EV2 For MDR2 EV2
EV4 For MDR4/43 EV4
H5-COVER H5K-COVER EV5 For MDR5 EV05

Control Circuit Switching 10Amp 250VAC Ui = 400V IP65

MDR43 F or use with a wide range of mediums including air, water, oils and refrigerants. LIMIT & PRESSURE SWITCHES & SENSORS
Medium temperature: Air -25 to +100°C. Water +100°C max. IP54

MDR43 Cut-out Pressure (Bar) Contacts Bursting Pipe Thread Code
Min Max Diff Strength
1 NO + 1 NC 1/4" BSP MDR43/3
0.5 3.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4" BSP MDR43/6
2.5 6.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4" BSP MDR43/11
5.0 11.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4" BSP MDR43/16
8.0 16 Adj Pz >60 Bar

MDR-F MDR-F H igh pressure range – for use with air, water, sea water, petrol, diesel, natural gas butane, propane,
nitrogen etc.

Medium temperature: +70°C max. IP54

0.5 8.0 Adj 1 C/O 10A Pz >40 Bar 3/8" BSP MDR-F8H-S
1.0 16.0 Adj 1 C/O 10A Pz >48 Bar 3/8" BSP MDR-F16H-S
2.0 32.0 Adj 1 C/O 10A Pz >64 Bar 3/8" BSP MDR-F32H-S
8.0 60.0 Adj 1 C/O 10A Pz >120 Bar 3/8" BSP MDR-F60HH-S

See page 283 for pressure diagrams. CON 284

LIMIT SWITCHES

Steel Type AH8 (28mm) IP65
• Contact: NC & NO 5A • Cable entry: Rubber Grommet

Code AH8111 AH8112 AH8122 AH8104 AH8107 AH8108 AH8166 AH8101 AH8169
180° Tilt Wobble 180° Tilt
Steel Type WL5 (40mm) IP65 180° Tilt Maintained Pull Switch
• Contact: NC & NO 10A • Cable entry: 20mm
Hole centres:
Pushbutton Pushroller Rollerball 20-22mm

Code WL5101 WL5102 WL5103 WL5104 WL5106 WL5107-2 WL5108-2 WL5105 AP5-T98
Compact Enclosed Type AH-7 IP65

Code AH-7100 AH-7110 AH-7310 AH-7311

LIMIT & PRESSURE SWITCHES & SENSORS Code AH-7312 AH-7120 AH-7140 AH-7121
Mounting holes

Code AH-7141 AH-7124 AH-7144

Specifications • Service life: Mechanically: 1 000 000 operations min
Electrically: 100 000 operations min
• Contact resistance: 25mΩ max (initial) • Current rating: 10A @ 250VAC C/O
• Insulation resistance: 100MΩ min (at 500VDC)
• Dielectric strength: 1 000VAC 50/60Hz for 1 min

285 HIG

LIMIT SWITCHES

Plastic Type AP1 – 30mm Width IP65

• EN50047
• Contact:

NC & NO
10A@24VAC
3A@240VAC
• Cable entry:
M20x1.5

Code AP5T11 AP5T13 AP5T31 AP5T41 AP5T51 AP5T52 AP5T71 AP5T91 AP5T92

Plastic Type BP1 – 40mm Width IP65

• EN50041

• Contact:
NC & NO
10A@24VAC
3A@240VAC

• Cable entry:
M20x1.5

Code BP5H12 BP5H19 BP5H33 BP5H43 BP5H53 BP5H54 BP5H91 BP5H92 BP5H93

Plastic Type DP1 – 50mm Width IP65

• C ontact:
1N/O & 1NC
10A@24VAC
3A@240VAC

• M20x1.5
Cable entry

• 2 x cable
entries

Code DP5T11 DP5T13 DP5T31 DP5T41 DP5T51 DP5T52 DP5T71 DP5T91 DP5T92 LIMIT & PRESSURE SWITCHES & SENSORS

Metal Pre-Wired • Type EM1 30W x 50H (mm) IP67 • Type EM2 33W x 70H (mm) IP67

• IEC 947-1
• E N60947-1
• Contact: 1N/O

& 1N/C
5A@24VAC
1A@240VAC
• Cable: 1m

EM2 mounting holes

EM1 mounting holes EM1G11Z EM1G12Z EM1G14Z EM1G21Z EM1G22Z EM1G24Z EM1G41Z EM1G42Z
Code side cable EM2G11Z EM2G12Z EM2G14Z EM2G21Z EM2G22Z EM2G24Z EM2G41Z EM2G42Z
Code bottom cable
HIG 286

MICRO SWITCHES

General purpose Z-type

Code Z15G-1701 Z15G-1702 Z15G-1703 Z15G-1704

Code Z15G-1744 Z15G-1300 Z15G-1305 Z15G-1306

Code Z15G-1307 Z15G-1705 Z15G-1308 Z15G-1318
Mounting holes
Specifications Terminal Cover for
• Contact resistance: 15mΩ max (initial) Z-type Micro Switches
• Insulation resistance: 100MΩ min (at 500VDC)
• Dielectric strength: 1 000VAC 50/60Hz for 1 min Z15G-1307

• Service life: Mechanically: 1 000 000 operations p/min 50mm

Electrically: 100 000 operations p/min

• Current rating: 15A @ 250VAC C/O

Type VS Micro switch (High mechanical life)

27mm

Code VS15P01C VS15P02C VS15P03C VS15P04C

Low torque

LIMIT & PRESSURE SWITCHES & SENSORS Code VS15P05C VS15P06C VS15P07C P-CS-71
Push Buttons
Specifications
Contact resistance: 15mΩ max (initial) Fits onto VS15P01C Micro Switch Hole Size 10mm
Insulation resistance: 100MΩ min (at 500VDC)
Dielectric strength: 1 000VAC 50/60Hz for 1 min

Service life: Mechanically: 1 000 000 operations p/min

Electrically: 100 000 operations p/min

Current rating: VS: 1C/O 15A @ 250V

P-CS: 1C/O 5A @ 250V

Code VAQ-5-* VAQ-4-* AB6161-* AB5151-*

Mounting holes HIG Hole Size 12mm
*Add colour of button: ●R, ● Y, ● GN

287

LIMIT & FOOT SWITCHES

Heavy Duty

Code 1NO + 1NC FS-1 FS-2 FS-3 FS-4 (SPDT)
FS-4/DP (DPDT)
Code 2NO + 2NC – – –
15A 250VAC
Contacts 10A 250VAC (SPDT) 10A 250V (SPDT) 10A 250V (SPDT) Aluminium
Enclosure material Steel cover Poly-carb Aluminium Not supplied (16mm entry)
Cable/Entry PVC 0.75mm x 3 core PVC 0.75mm x 3 core PVC 0.75mm x 3 core IP54
IP rating IP40 IP40 IP40 Z15G-1704
Spare contact 1NO + 1NC – – –

Footswitch - With locking device in neutral Steel Mounting Frames Safety Limit Switches
IP67
position (Pedal in the up position) Without foot switch

400mm

WW

Code 1NO+1NC FS-PS1211 (SPDT) Code Description Width

Code 2NO+2NC FS-PS1213 (DPDT)

Contacts 10A 250VAC PD-1000 For 2 foot 350mm
Code
Enclosure material Shock resistant ABS switches EDR-6-1-22 EDR-6-1-27 EDR-6-1-32
700mm
IP rating IP65 For 4 foot 1NO + 1NC (3A 230VAC)
Cable/Entry Cable Entry 20mm
Spare contact for Not supplied (PG16 entry)
Z11 PD-1002 switches
Latching limit switch manual pull to reset
1NO+1NC

Safety Limit Switches Keys

K101 LIMIT & PRESSURE SWITCHES & SENSORS

90˚ adjustable head 360˚ fully turnable head K100

Code SP5K20 SP5K120 K101 K100
Key
Contact K101/K100 Key fits on front or top of the limit switches
Enclosure
Dimensions (mm) 1NO + 1NC 3A@240VAC Order key separately

IP65 Plastic body

30 x 30 x 90 – M20 entry

HIG 288

ROPE PULL SWITCHES

Rope Mounting holes Contacts Rope Pull Switches
Pull for PL-967 1NO + 1NC
Latching Housing IP65 Code Description
3A/400VAC
PL-967 4kg rope pull switch
Latching on rope break
Rope Accessories PL-967-7.5KG 7.5kg rope pull switch

PL-967-15KG 15kg rope pull switch

Features Safety Rope Break Switches
• Complies to IEC-947-5-1
• 1NO + 1NC Positive Action With reset SM5K98X11 SBM5K99X11
• AC-15 = 3A at 230V. ui = 690V
• For cable lengths up to 6 metres Without reset SM5K96X11 SBM5K97X11

MET Not latching Weight 4.7kg 6.7kg
Dimensions 30 x 30 x 143 40 x 44 x 162
M20 entry M20 entry
IP Rating IP65 IP66
Enclosure Die-cast Body Die-cast Body

Code PWR SB209331/6 SB209332/6.5 SB209333/M8 SB209333/M10 SB209333/M12 SB209336/8
M8 Eye bolt
Description Steel Wire. PVC sheathed Thimble Clamp M10 Eye bolt M12 Eye bolt Tensioner
rope. 100m. Ø5mm Red. 6mm 6.5mm 8mm

CONVEYORS SAFETY SWITCHES

Safety Cable Pull Switches Belt Alignment Switch Speed Monitor

IP67 IP67 IP65

Code SRS SRT ED400
Switching Capacity SPDT x 2 10A@250VAC SPDT x 2 10A@250VAC
Action Force 49 ± 9.8n 3.4-5.4N.m Specifications
(5±1kgf.m) (0.35-0.55kgf.m)
Reset Manual Auto • Speed: 0~999rpm
Ambient Temp -20-60˚C -20-60˚C • 7-seg LED display: 0~999
Enclosure Material Die-Cast Aluminium Die-Cast Aluminium • Alarm set point: 1~1999rpm
Weight Approx. 2.9kg 2.9kg • Rotate direction: CW or CCW
Certified for use in • Alarm: Underspeed, Standstill, Reverse, Power Failure
LIMIT & PRESSURE SWITCHES & SENSORS Zone 21/22 Standard Slack Rope Ripped/Torn • Speed output: 4~20mA
Conveyor Belt Conveyor Belt Conveyor Belt • Supply: 85~265VAC
• Ambient Temperature: -20˚~70˚C
Trip Switch Trip Switch Trip Switch • Housing: Die-cast Aluminium

Conveyor Belt Alignment
Switch

CHW53201

Code CHW93053 CHW93058

Type 1NO/NC 2NO/2NC

PT125CW5000 CHW53198 CHW53198A CHW53198B Switching Capacity 3A @ 230VAC 10A @ 230VAC
CHW53197 - Protection rating IP65
Code Single End CHW53197A Cable Entries
Code Double End 10A @ 230VAC HIG 1 x M20
Rated Continuous Current
Protection rating IP66 Accessories for Conveyor Belt Trip Switches
Cable Entries 3 x M20
Code Description
289 CHW53201 Padlock Attachment
PT125CW5000 Pigtail M10 x 125mm

COMPACT RECTANGULAR/SQUARE INDUCTIVE SENSORS IP67

3 Wire DC Inductive Sensors 2 Wire DC
Inductive

NPN NO PS17-5DN PS17-8DN PFI25-8DN PSN25-5DN PSN30-10DN PSN30-15DN PSN40-20DN PS50-30DN NO Output
PNP NO PS17-5DP PS17-8DP PFI25-8DP PSN25-5DP PST17-5DO
NPN NC PS17-5DN2 PS17-8DN2 PFI25-8DN2 PSN25-5DN2 PSN30-10DP PSN30-15DP PSN40-20DP PS50-30DP NC Output
PNP NC – – PFI25-8DP2 PSN25-5DP2 PST17-5DC
PSN30-10DN2 PSN30-15DN2 – PS50-30DN2

PSN30-10DP2 PSN30-15DP2 PSN40-20DP2 PS50-30DP2

Switching distance 5mm ±10% 8mm ±10% 5mm ±10% 10mm ±10% 15mm ±10% 20mm ±10% 30mm ±10% 5mm ±10%

Hysteresis Max. 10% of switching distance

Standard detecting 18 x (1Ir8onx ) 25 x 25 x 1mm (Iron) 30 x 30 x 45 x 45 x 60 x 60 x 90 x 90 x 18 x 18 x
target 1mm 1mm (Iron) 1mm (Iron) 1mm (Iron) 1mm (Iron) 1mm (Iron)

Response frequency 700Hz 200Hz 300Hz 250Hz 200Hz 100Hz 50Hz

Dimensions 17 x 17 x 31 26 x 10 x 49 25 x 25 x 39 30 x 30 x 53 40 x 40 x 53 53 x 53 x 35 17 x 17 x 31

Protection circuit Surge protection circuit. Surge protection circuit. Reverse polarity protection. Surge
Reverse polarity protection Overload & short-circuit protection Protection Circuit

Power supply 12-24VDC

(Operation voltage) (10-30VDC)

Leakage current Max. 10mA

Residual voltage Max. 1.5V Max. 4V

Affection by Temp. -25 to +70°C

Control output 200mA 2-100mA

Insulation resistance Min. 50MΩ (at 500VDC)
Operation indicator (Red LED)
Indicator

Ambient temperature -25 – +70°C (at non-freezing status)

2 Wire AC Inductive Sensors

NO Output PSN25-5AO PSN30-10AO PSN30-15AO PSN40-20AO

NC Output PSN25-5AC PSN30-10AC PSN30-15AC PSN40-20AC

Switching distance 5mm ±10% 10mm ±10% 15mm ±10% 20mm ±10%

Hysteresis Max. 10% of switching distance

Standard detecting 25 x 25 x 1mm 30 x 30 x 1mm 45 x 45 x 1mm 60 x 60 x 1mm
(Iron) (Iron) (Iron)
target (Iron)

Dimensions 25 x 25 x 39 30 x 30 x 53 30 x 30 x 53 40 x 40 x 53

Power supply 100-240VAC

(Operation voltage) (85-264VAC)

Leakage current Max. 2.5mA

Response frequency 20Hz

Residual voltage Max. 10V

Affection by Temp. ±10% Max. for detecting distance at +20°C within temperature range of -25 – +70°C LIMIT & PRESSURE SWITCHES & SENSORS

Control output 5-200mA

Insulation resistance Min. 50MΩ (at 500VDC)

Indicator Operation indicator (Red LED)

Ambient temperature -25 to +70°C (at non-freezing status)

Protection Circuit Surge protection circuit

AUTO DOOR SENSOR

Code ADS-A
Supply Voltage 24-240VAC
Relay Output 0.1A @ 50VDC
Mounting Height 2-2.7m (max. detecting distance: 3m)
Output Delay Time 2/7/15 sec selectable by dip switch
Detection Four angles for front detection area, 7.5°, 14.5°,
21.5°, 28.5°
Right/Left detection area elimination function

Also see page 316

SCA 290

MAGNETIC PROXIMITY SWITCHES IP67

Reed Contact Magnetic Switches (Cable length 2m)

Nickel Plated Brass Housing SM19 SM02
SM21
SM22
Plastic Housing

Nickel Plated Brass Housing

Diameter/Length Code Amps Code Amps Code Amps Code Amps
N/O 30VDC 250VAC N/O+N/C 30VDC 250VAC N/O 30VDC 250VAC N/O + N/C 30VDC 250VAC
0.1A 0.01A –– –– ––
8 30mm SM03 0.33A 0.04A – 0.33A 0.04A – –– – ––
–– SM06 0.1A 0.01A – 1.6A 0.2A – ––
10 30mm SM05 –– SM08 –– SM09 3A 0.4A – 3A 0.4A
–– – –– SM13 3A 0.4A SM14 2A 0.25A
12 40mm – – SM17 SM18

12 70mm –

18 70mm –

Plastic Housing N/O N/O+N/C N/O Bistable N/O
Diameter/Length
6 38mm – –– SM02 0.1A 0.01A – –– – – –
12 100mm SM19 1.6A 0.2A –– – SM21 0.4A
Specifications 3A 0.4A SM22 3A

Wiring Diagrams

• Max Voltage: 230VAC
• Switching Frequency: 200Hz
• Delay on Activation: N/O + N/C
• Repeatability: 2mS N/O

• Temperature Limits: ± 0.3mm

-20 to + 60 °C
• Cable section (N/O): 2 x 0.50mm2
• Cable section (N/O N/C): 3 x 0.50mm2

Hall Effect Magnetic Proximity Switches 12-30VDC IP67

Type Code Bi-lateral Sensing Code Frontal Sensing • Voltage 12-30VDC Bi-lateral sensing
• Fast 50µsec on/off Frontal sensing
12mm 18mm 12mm 18mm • LED yellow: output on
• LED green: supply on Bi-lateral sensing
PNP N/O - HS05B HS03F HS05F • Switching frequency 10kHz
• Max output 200mA
PNP N/C HS04B HS06B HS04F HS06F • Nickel Plated Brass housing
• Cable length 2m

Reed Contact Switch / Magnet Switching distances (mm)

MG01 MG02 MG03 MG04 MG05

Distance Hysteresis Distance Hysteresis Distance Hysteresis Distance Hysteresis Distance Hysteresis

LIMIT & PRESSURE SWITCHES & SENSORS Diameter 6 24 5 22 5 6 2.5 32 5 29 5

Diameter 8 24 5 22 5 6 2.5 32 5 29 5

Diameter 10 24 5 22 5 6 2.5 32 5 29 5

Diameter 12 (L=40mm) 24 5 22 5 6 2.5 22 9 20 9

Diameter 12 (L=70mm) 12 7 10 6 – – 22 9 20 9

Diameter 18 12 7 10 6 – – 22 9 20 9

Warning: The data specified in this table has an approximate value because it depends on the magnet position, the material on which it is applied ­(ferromagnetic or
not) and because it is related to the magnet during the frontal approach. Reed contact sensors can also be activated laterally considering that switching distances are
always influenced by the magnet position, orientation and the material on which it is applied (ferromagnetic or not).

Magnets Dimensions (mm)

291 DAT

SQUARE INDUCTIVE PROXIMITY SWITCHES IP67

Square 40x40mm AS80 Square 80x80mm

• PBT (resin) or Nickel-plated 65 80
Brass Housing
• Operating Distance 1.5 ... 15mm –
• 40x40mm or 8x8mm dimension 50mm
• Cable, M8/M12 Connector or 12-48VDC
Terminal Block 200mA
• 2 or 3 Wires
• PNP, PNP/NPN, NO, NC, NO/NC –
100Hz
Short Housing M12 Plug* Cable

Available Shielded Not Shielded Shielded Not Shielded –
Switching Distance (Sn) 1.5mm
Operating Voltage 15mm 30mm 15mm 30mm 10-30VDC
Max Output Current 200mA
Operation LED 10-30VDC 20-250 VAC/DC Yellow
Switching Frequency 500Hz
Connection 200mA 200mA *M8 Plug, Cable

Dimensions Yes Yes

100Hz 25Hz AC; 40Hz Dc Terminal

M12 Plug*, Terminal Block Block

40 LED 30
46 60 PG 13.5

40 118 11
65 23 40

40

Ø22.4 15
20

34 M12x1

OUTPUT: 40 26

PNP NO –––– – IS-88-Q1-03*
AS80-50DN3 –
NPN NO + NC IS-40-W6-03 IS-40-Y6-03 – – –
– –
NPN NO + NC Short Housing M12 Plug* IS-40-X6-S2 – – – AS80-50P3 –

PNP NO + NC IS-40-W5-03 IS-40-Y5-03 – – – –

PNP NO + NC Short Housing M12 Plug* IS-40-X5-S2 – – – –

2 Wires AC/DC NO – – IS-40-W7-03 IS-40-Y7-03 LIMIT & PRESSURE SWITCHES & SENSORS

2 Wires AC/DC NC – – IS-40-W8-03 IS-40-Y8-03

*For M8 plug type replace 03 with S1 e.g. IS-88-Q1-S1

For sensor cable and accessories see pages 329-332

DC SENSOR TESTER

For M12 Connector, Cable & Terminal DC Sensors

Code Description
ST-02 • PNP (sourcing) and NPN (sinking) Testing
• M12-5-Pin Plug Input
• Terminal Inputs
• Two Output LED's

• Battery Powered

DAT 292

DC 2 WIRE 10-30VDC INDUCTIVE PROXIMITY SWITCHES IP67

DC DC DC

Diameter Ø12 Ø18 Ø30
Shielded Non Shielded

• Nominal Voltage: 10-30VDC
• Max. Output Current: 100mA
• Temperature Range: -25 to 70°C
• Housing Material: Nickel Plated Brass
• Cost Effective

Switching Distance 2mm 4mm 5mm 8mm 10mm 15mm
Operation LED Yellow Yellow Yellow
Switching Frequency 1000Hz 1000Hz View of male 300Hz
Cable Length 2m 2m connector 2m
Wiring Diagrams M12
BROWN
For sensor cable and
accessories see pages 329-332 NO Configuration of Contacts

BLUE N. contacts
BLUE Available
1 2 3 4
NC NO + _
NC _ +
BROWN

OUTPUT: IS-12-A9-03 IS-12-C9-03 IS-18-A9-03 IS-18-C9-03 IS-30-A9-03 IS-30-C9-03
NO-NC programmable Cable IS-12-A9-S2 IS-12-C9-S2 IS-18-A9-S2 IS-18-C9-S2 IS-30-A9-S2 IS-30-C9-S2
NO-NC programmable (M12 connector)

SPECIAL DC INDUCTIVE PROXIMITY SWITCHES IP67

Weld Field Immune Metal Face

Diameter Ø12 Ø18 Ø12 Ø18

Shielded Non Shielded

• Nominal Voltage: 10-30VDC
• Max. Output Current: 200mA
• Temp. Range: -25 to 70°C
• Housing Material: Stainless
Steel
• Weld field immune is
intrinsically safe and used in
welding bays.

LIMIT & PRESSURE SWITCHES & SENSORS Switching Distance 2mm 4mm 5mm 8mm 2mm 4mm 5mm 8mm
Operation LED Present 1000Hz Present 500Hz Present 1000Hz Present 500Hz
Switching Frequency 2000Hz 1000Hz 2000Hz 1000Hz
Active Face Material ETFE ETFE Stainless Steel Stainless Steel
Wiring Diagrams
View of quadripole Configuration of Contacts
For sensor cable and male connector
accessories see M12 N. contacts
pages 329-332
Available 1 2 3 4
NO + - no

OUTPUT: IS-F12-S1-S2 IS-F12-T1-S2 IS-F18-S1-S2 IS-F18-T1-S2 IS-12-I1-S2 IS-12-L1-S2 IS-18-I1-S2 IS-18-L1-S2
PNP NO M12 Plug

293 DAT

24-250VAC/VDC INDUCTIVE PROXIMITY SWITCHES NO OR NC IP67

Diameter Ø 12 Ø 18 Ø 30

Shielded Non Shielded

• Current output 200mA max

Switching Distance 2mm 4mm 4mm 8mm 5mm 8mm 8mm 16mm 10mm 16mm 15mm 25mm
Nominal Voltage 20-250VAC/VDC 20-250VAC/VDC
Max Output Current 20-250VAC/VDC 200mA 200mA
Switching Frequency 25Hz AC/ 35Hz DC 25Hz AC/ 35Hz DC
Operating Temperature 200mA -25°C to 75°C -25°C to 75°C
Sensing Face PBT PBT
Housing 25Hz AC/ 35Hz DC Nickel Plated Brass Nickel Plated Brass
Connection Cable 2m, M12 Plug Cable 2m, M12 Plug
Operation LED -25°C to 75°C Present Present
Wiring Diagram
PBT

Nickel Plated Brass

Cable 2m, M12 Plug

Present

Dimensions

M12x1 M12x1 M12x1 M12x1 M18x1 M18x1 M18x1 M18x1 M30x1,5 M30x1,5 M30x1,5 M30x1,5

60 52 8 26 55 5 43 12 55 40 15 15 15
42 34 60 8 79 LEDx4 64 15
79
26 15 15
68 38 79

M12 Connector LED LED LED
LED LED

LED LEDx4 LEDx4 M12x1 LEDx4 M12x1
LEDx4 15 15
OUTPUT: M12x1
LEDx4
15 15
M12x1 M12x1 M12x1

NO Output (Cable Type) IPS12-S2UO60*-A2P IPS12-N4UO60*-A2P IPS18-S5UO55**-A2P IPS18-N8UO55**-A2P IPS30-S10UO55**-A2P IPS30-N15UO55**-A2P

Double Sensing IPS12-S4UO60*-A2P IPS12-N8UO60*-A2P IPS18-S8UO55**-A2P IPS18-N16UO55**-A2P IPS30-S16UO55**-A2P IPS30-N25UO55**-A2P

NC Output (Cable Type) IPS12-S2UC60*-A2P IPS12-N4UC60*-A2P IPS18-S5UC55**-A2P IPS18-N8UC55**-A2P IPS30-S10UC55**-A2P IPS30-N15UC55**-A2P

Double Sensing IPS12-S4UC60*-A2P IPS12-N8UC60*-A2P IPS18-S8UC55**-A2P IPS18-N16UC55**-A2P IPS30-S16UC55**-A2P IPS30-N25UC55**-A2P

*For plug type replace 0-A2P with 8-A12 For sensor cable and accessories see pages 329-332

**For plug type replace 55-A2P with 79-A12

ANALOG INDUCTIVE PROXIMITY SWITCHES 0-10V 4-20mA IP67

Diameter Ø 12 Ø 18 Ø 30

Shielded Non Shielded 0.6-6mm 3.1-10mm 3.1-10mm 7.3-20mm 7.3-20mm 17.6-40mm
Measuring Distance
Nominal Voltage 18-30VDC 18-30VDC 18-30VDC
Load Resistor
Output Following Frequency V: > 2 kOhm, A: 400 Ohm V: > 2 kOhm, A: 400 Ohm V: > 2 kOhm, A: 400 Ohm LIMIT & PRESSURE SWITCHES & SENSORS
Operating Temperature
Sensing Face 100Hz 100Hz 100Hz
Housing
Connection 0°C to 70°C 0°C to 70°C 0°C to 70°C
Wiring Diagram
PBT PBT PBT

Nickel Plated Brass Nickel Plated Brass Nickel Plated Brass

Cable 2m Cable 2m Cable 2m

Dimensions

OUTPUT:

Voltage 0-10V IA12-S6V010-2NP IA12-N10V010-2NP IA18-S10V010-2NP IA18-N20V010-2NP IA30-S20V010-2NP IA30-N40V010-2NP
IA12-N10I420-2NP IA18-S10I420-2NP IA18-N20I420-2NP IA30-S20I420-2NP IA30-N40I420-2NP
Current 4-20mA IA12-S6I420-2NP
SCA 294

DC INDUCTIVE PROXIMITY SWITCHES STANDARD & SHORT »

Diameter NPN or PNP Ø5 Ø6.5 DC Ø8

Shielded Non Shielded

• Nominal Voltage 10-30VDC
• 4 Wire programing type
• 3 Wire plug and cable type
• Standard & Short Housing versions

For Sensor Cable & Acces-
sories see pages 329-332

Nominal Switching Distance (Sn) 0.8mm 1.5mm 2mm 2mm
200mA
Max. Output Current 100mA 200mA Present (Yellow)
1000Hz
Operation LED Present Present -20 to 60°C
2m
Switching Frequency 2000Hz 1000Hz Nickel plated brass

Temperature Limits -25 to 60°C -25 to 70°C *For plug type M12 change 'S1' to 'S2' e.g. IS-08-G3-S2

Cable Length 2m 2m

Housing Material Stainless Steel Nickel-plated brass

View of male connector M12 Wiring Diagrams *For plug type M8 change '03' to 'S1' e.g. IS-65-A3-S1

4

13

Contacts Numbers

OUTPUT: Available 1 3 4 3 wire sensors
NPN/PNP BROWN BLUE BLACK
M8 Plug Type
+ __ NO/NC

NPN & PNP, (NO & NC) Cable type (4 Wire) – – – Cable Type
– –
NPN & PNP, (NO & NC) M12 connector (4 Wire) – IS-65-A1-03* IS-65-C1-03*
IS-65-A2-03* IS-65-C2-03*
PNP NO output (3 Wire) IS-05-A1-03* IS-65-A3-03* IS-65-C3-03* IS-08-G1-03 IS-08-G1-S1*
IS-65-A4-03* IS-65-C4-03* IS-08-G2-03 IS-08-G2-S1*
PNP NC output (3 Wire) – IS-08-G3-03 IS-08-G3-S1*
IS-08-G4-03 IS-08-G4-S1*
NPN NO output (3 Wire) IS-05-A3-03*

NPN NC output (3 Wire) –

NAMUR INDUCTIVE PROXIMITY SWITCHES IP67

Diameter DC DC DC DC Ø30
Ø8 Ø12 Ø18

Shielded Non Shielded

LIMIT & PRESSURE SWITCHES & SENSORS Switching Distance (± 20%) 1mm 2mm 2mm 4mm 5mm 8mm 10mm 15mm

Nominal Voltage (Load Resistance 1K) 7.7-9VDC 7.7-9VDC 7.7-9VDC 7.7-9VDC

Supply Voltage 5-24VDC 5-24VDC 5-24VDC 5-24VDC

Switching Frequency 2000Hz 2000Hz 1000Hz 500Hz

Cable IS-08-A20-03 IS-08-C20-03 IS-12-A20-03 IS-12-C20-03 IS-18-A20-03 IS-18-C20-03 IS-30-A20-03 IS-30-C20-03

Plug-in (M12 Connector) IS-08-A20-S2 IS-08-C20-S2 IS-12-A20-S2 IS-12-C20-S2 IS-18-A20-S2 IS-18-C20-S2 IS-30-A20-S2 IS-30-C20-S2

NPN NO-NC - - - - - - - -

PNP NO-NC - - - - - - - -

Relay Output: 18 to 240VAC/DC - - - - - - - -

Wiring Diagrams View of male connector M12 Configuration of Contacts

N. contacts

Available 1 2 3 4

NAMUR + _

For Sensor Cable & Accessories Note: Can only be used with AC/DC
see pages 329-332 NAMUR Relay "NSI" or instruments with
NAMUR inputs

295 DAT

» HOUSING 3 WIRE OR 4 WIRE PROGRAMMABLE OUTPUT IP67

DC Ø12 DC Ø18 DC Ø30

2mm 4mm 4mm 8mm 5mm 8mm 8mm 14mm 10mm 15mm 15mm 20mm

200mA 200mA 200mA

Present (Yellow) Present (Yellow) Present (Yellow)

1000Hz 1000Hz 300Hz

-25 to 70°C -25 to 70°C -25 to 70°C

2m 2m 2m

Nickel plated brass Nickel plated brass Nickel plated brass

*For plug type M12 change '03' to 'S2' e.g. IS-12-A3-S2

Housing Lengths (mm)

Standard Short

Connector Cable Connector Cable

SH NS SH NS SH NS SH NS
M12 68 72 58 64 48 54 42 48

M18 73 82 70 78 56 65 47 56

4 wire sensors programmable output 3 wire sensors M30 74 85 70 82 56 68 49 56

IS-12-A0-03 IS-12-E0-03 IS-12-C0-03 IS-12-F0-03 IS-18-A0-03 IS-18-E0-03 IS-18-C0-03 IS-18-F0-03 IS-30-A0-03 IS-30-E0-03 IS-30-C0-03 IS-30-F0-03

IS-12-A0-S2 IS-12-E0-S2 IS-12-C0-S2 IS-12-F0-S2 IS-18-A0-S2 IS-18-E0-S2 IS-18-C0-S2 IS-18-F0-S2 IS-30-A0-S2 IS-30-E0-S2 IS-30-C0-S2 IS-30-F0-S2

IS-12-A1-03* IS-12-G1-03* IS-12-C1-03* IS-12-H1-03* IS-18-A1-03* IS-18-G1-03* IS-18-C1-03* IS-18-H1-03* IS-30-A1-03* IS-30-G1-03* IS-30-C1-03* IS-30-H1-03*

IS-12-A2-03* IS-12-G2-03* IS-12-C2-03* IS-12-H2-03* IS-18-A2-03* IS-18-G2-03* IS-18-C2-03*IS-18-H2-03* IS-30-A2-03* IS-30-G2-03* IS-30-C2-03* IS-30-H2-03*

IS-12-A3-03* IS-12-G3-03* IS-12-C3-03* IS-12-H3-03* IS-18-A3-03* IS-18-G3-03* IS-18-C3-03* IS-18-H3-03* IS-30-A3-03* IS-30-G3-03* IS-30-C3-03* IS-30-H3-03*

IS-12-A4-03* IS-12-G4-03* IS-12-C4-03* IS-12-H4-03* IS-18-A4-03* IS-18-G4-03* IS-18-C4-03* IS-18-H4-03* IS-30-A4-03* IS-30-G4-03* IS-30-C4-03* IS-30-H4-03*

CAPACITIVE SENSORS 12-30VDC NPN OR PNP 18-240VAC/DC RELAY OUTPUT IP67

DC DC AC AC
Ø18 Ø30 Ø30 Ø18/*Ø30 Available

1-5mm 1-10mm 1-20mm 1-25mm 1-20mm 2-30mm 2-8mm *2-20mm 2-15mm *2-30mm LIMIT & PRESSURE SWITCHES & SENSORS
- -
12-30VDC (-15/+10%) 12-30VDC (-15/+10%) --
10Hz 10Hz
- - - - 18-230VAC/DC (-15/+10%) 50Hz 20-250VAC/DC (-15/+10%) 50Hz
- - - -
CS-07 CS-13 CS-09 CS-15 10Hz 25Hz (Ø18) 25Hz (Ø18)
CS-08 CS-14 CS-10 CS-16
- - - - - - N/O CCM1-1808A-A3L2 CCM2-1815A-A3L2
- - N/C CCM1-1808A-B3L2 CCM2-1815A-B3L2
Ex Class II
- - *2-20mm(Ø30) *2-30mm(Ø30)

- - N/O CCM1-3020A-A3L2 CCM2-3020A-A3L2

CS-31 *CS-31TE CS-32 *CS-32TE N/C CCM1-3020A-B3L2 CCM2-3020A-B3L2

*with 1s-5m time activating delay.

Relay Output

DAT 296

M12 DC PHOTOELECTRIC SENSOR PLASTIC AND METAL PNP/NPN IP67

Type DC M12 Ø12 Diffuse Proximity Retro-Reflective Through Beam

M12 SERIES Non-Polarized Polarized

• Nominal Voltage 10-30VDC
• Output: NPN or PNP
• Output Current: 150mA
• Housing Material: PBT (plastic v)
Nickel Plated Brass ( metal v)
• Temperature Range: -25 to 70°C

Sensing Distance 200mm 2m 1m 5.2m

DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30Vdc

Emission Infrared LED 880nm Infrared LED 880nm Red light 660nm Infrared LED 880nm

Setting sensitivity trimmer sensitivity trimmer sensitivity trimmer sensitivity trimmer

Switching Frequency 1kHz 1kHz 1kHz 25Hz

Operation Mode Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^

Wiring Diagrams PNP Output Type Emitter of Thru-beam Mode

NPN Output Type

^Light/Dark changeover by the A. load or B. load ^Light/Dark changeover by the A. load or B. load

OUTPUT: Metal Housing Version Plug Type

NPN Cable Version M12P*-D0200N-CX9C4U2** M12P*-L2000N-CX9C4U2** M12P*-L1000N-CX6C4U2**-PF M12P*-T5200N-CX9C4U2**
PNP Cable Version
Emitter Cable Version M12P*-D0200P-CX9C4U2** M12P*-L2000P-CX9C4U2** M12P*-L1000P-CX6C4U2**-PF M12P*-T5200P-CX9C4U2**
Emitter M12 Plug Version
- - - M12P*-T5200D-EX9C3L2

- - - M12P*-T5200D-EX9Q4LE

*For metal type replace P with B e.g. M12B-D0200N-CX9C4U2 **For plug type replace C4U2 with Q4UE e.g. M12P-D002N-CX9Q4UE

For Sensor Cables and accessories see pages 329-332

MINI BEAM PHOTOELECTRIC SENSOR PNP AND NPN CONFIGURABLE IP67

Type DC Diffuse Proximity Retro-Reflective Through Beam
MP SERIES Medium Distance Fixed Focus
Non-Polarized Polarized

• Nominal Voltage 10-30VDC
• Output: NPN or PNP Configurable
• Output Current: 150mA
• Housing Material: Reinforced
Thermoplastic Polyester
• Temperature Range: -25 to 70°C

LIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 380mm 16mm 0.1-5m 2m 0-3m
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 880nm Infrared LED 880nm Red light 650nm Red light 650nm Infrared LED 880nm
Setting sensitivity trimmer sensitivity trimmer sensitivity trimmer sensitivity trimmer
Switching Frequency** 1kHz 1kHz 1kHz 1kHz 25Hz
Operation Mode Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON
select switch select switch select switch select switch select switch
Pico Style Pigtail Plug Type Wiring Diagrams

OUTPUT: NPN/PNP Emitter of Thru-beam Mode
NPN & PNP Cable Version
NPN & PNP M8 Pigtail Pico** MP-D0380D-CX9C4U2 MP-C0016D-CX9C4U2 MP-L5000D-CX6C4U2 MP-L2000D-CX6C4U2-PF MP-T3000*D-CX9C4U2
Emitter Cable Version
Emitter M8 Pigtail Pico** MP-D0380D-CX9P4UP MP-C0016D-CX9P4UP MP-L5000D-CX6P4UP MP-L2000D-CX6P4UP-PF MP-T3000*D-CX9P4UP

297 - - - - MP-T3000*D-EX9C3L2

- - - - MP-T3000*D-EX9P4LP

*For units with 30m sensing distance change 3000 to 030M e.g. MP-T030MD-CX9C4U2

For sensor cable and accesssories see pages 329-332. **High Speed Type available on request

SCA

AC PHOTOELECTRIC SENSORS 3 WIRE DARK/LIGHT MODE IP67

Type AC M18 Ø18 Fixed Focus Short Distance Medium Distance Retro-Reflective Through Beam Through Beam
Proximity Diffuse Proximity Diffuse Proximity Receiver Emitter
S5 SERIES

• Nominal Voltage 15-264VAC
• Output: SCR + Bidge Rectifier
• Max. Output Current: 100mA
• Temperature Range: -25 to 55°C
• Housing Material: ABS
• Switching Frequency: 25Hz

Sensing Distance 15mm 80mm 300mm 0.1-4m (R2 Reflector*) 8m 8m
AC Supply Voltage 15-264VAC
Emission 15-264VAC 15-264VAC 15-264VAC 15-264VAC 15-264VAC Infrared LED 880nm
Setting –
Output LED Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Red
Dimensions
– – Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
OUTPUT:
Dark Mode. Cable Version Red Red Red Red Red
Light Mode. Cable Version AC AXIAL VERSION
Wiring Diagrams
23.5 Models S5
For sensor cable and Output LED With trimmer Without Trimmer
accessories see pages 329-332 Power on LED

22 3.2 X1 52 42
L 75 65
LIMIT & PRESSURE SWITCHES & SENSORS
S5-1-D15-10 S5-1-C8-10 S5-1-C30-10 S5-1-A2-10 S5-1-F8-10 S5-1-G8-00
S5-1-D15-20 S5-1-C8-20 S5-1-C30-20 S5-1-A2-20 S5-1-F8-20

Light = NO. Dark = NC Receiver
For Radial Optics 90° Sensing use DEV90 Accessory

Emitter

S5 SERIES AXIAL 10-30VDC 4 WIRE CONFIGURABLE DARK/LIGHT MODE IP67

Type DC M18 Ø18 Diffuse Proximity Retro-Reflective Through Beam
S5 SERIES
Short Medium Long Fixed Focus Non- Polarized Receiver Emitter
• Nominal Voltage 10-30VDC Distance
• Output: NPN or PNP Configurable Distance Distance Polarized
• Max. Output Current: ≤150mA
• Temp. Range: -25 to 55°C
• Housing Material: ABS

Sensing Distance 100mm 350mm 600mm 15mm 4m(R2 Reflector)* 3m(R2 Reflector)* 12m 12m

Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC

Emission Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Red LED 880nm

Setting Sensitivity – – Sensitivity Sensitivity – – Sensitivity

trimmer trimmer trimmer trimmer

Output LED Red OUTPUT Red OUTPUT Red OUTPUT Red OUTPUT Red Power

Green STABILITY Green STABILITY Green STABILITY Green STABILITY

Switching Frequency 500Hz 500Hz 500Hz 250Hz

Dimensions
For sensor cable and
accessories see pages 329-332.
For Radial Optics 90° Sensing use
DEV90 Accessory
OUTPUT:

NPN & PNP Dark/Light.Cable Version S5-5-C10-30 S5-5-C35-30 S5-5-C60-30 S5-5-D15-30 S5-5-A4-30 S5-5-B3-30 S5-5-F12-30 S5-5-G12-00
S5-5-C60-32 S5-5-D15-32 S5-5-A4-32 S5-5-B3-32 S5-5-F12-32 S5-5-G12-02
NPN & PNP Dark/Light. M12 plug* S5-5-C10-32 S5-5-C35-32

Plug Type Wiring Diagrams

DAT 298

DC PHOTOELECTRIC SENSORS SHORT HOUSING PLASTIC »

Type DC M18 Ø18 Diffuse Proximity Medium Distance Long Distance Fixed Focus
Short Distance
S15 SERIES

• Nominal Voltage 12-30VDC
• Output: NPN or PNP
• Output Current: ≤100mA
• Temperature Range: -25 to 55°C
• New stainless steel models
• IP67+IP69K on all models
• Johnson Diversey certification for
detergents
• Atex II 3dg certification

Sensing Distance 1-10cm 1-35cm 1-100cm 1-5cm
DC Supply Voltage 12-30VDC 12-30VDC
Emission 12-30VDC 12-30VDC Infrared LED 880nm Red LED 660nm
Setting Sensitivity Trimmer* -
Output LED Infrared LED 880nm Infrared LED 880nm Yellow Output LED Yellow Output LED
Switching Frequency 500 Hz 1Khz
Operation Mode – Sensitivity Trimmer* Light/Dark Selectable^ Light/Dark Selectable^
S15-PA-2/3
Yellow Output LED Yellow Output LED S15-PA/NA-5

500 Hz 500 Hz

Light/Dark Selectable^ Light/Dark Selectable^

Dimensions S15-PA-2/3-D50

A01/B01/C31/ M01
T01/F01/G01

OUTPUT: L 48.8 53.3
NPN Cable
PNP Cable L1 32.85 37.55
NPN M12 Plug
PNP M12 Plug S15-PA-2-C00-NK S15-PA-2-C10-NK - S15-PA-2-D50-NK
NPN M12 Plug Stainless Steel
PNP M12 Plug Stainless Steel S15-PA-2-C00-PK S15-PA-2-C10-PK - S15-PA-2-D50-PK

– S15-PA-5-C11-NK S15-PA-5-C31-NK -

– S15-PA-5-C11-PK S15-PA-5-C31-PK -

– S15-NA-5-C11-NK S15-NA-5-C31-NK -

– S15-NA-5-C11-PK S15-NA-5-C31-PK -

*Sensitivity trimmer on M12 Plug Units Only For sensor cable and accessories see pages 329-332

DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN NO-NC IP67

Type DC M18 Ø18 Diffuse Proximity

S50 SERIES Short Distance Medium Distance Long Distance Fixed Focus

• Nominal Voltage 10-30VDC 400mm
• Output: NPN or PNP 10-30VDC
• Contacts: NO and NC Infrared LED 880nm
• Output Current: ≤100mA –
• Housing Material: PBT - Lens PMMA Sensitivity trimmer
• Temperature Range: -25 to 55°C Yellow/Green (stability)
''One For All" 1kHz
• Flat plastic or cylindrical metal housing Dark on NO / light on NC
• Versions with Trimmers
• Cable or M12 Connection
• EN standard NPN or PNP NO-NC
configuration

Sensing Distance 100mm 700mm 100mm
10-30VDC 10-30VDC
DC Supply Voltage 10-30VDC Infrared LED 880nm Red LED 630nm
– –
LIMIT & PRESSURE SWITCHES & SENSORS Emission Red 630nm Sensitivity trimmer –
Yellow/Green (stability) Yellow
Minimum Detectable Object – 1kHz 1kHz
Dark on NO / Light on NC Dark on NO / light on NC
Setting –
M12 Connector
Output LED Yellow

Switching Frequency 1kHz

Operation Mode Dark on NO / Light on NC

Metal Housing Version Wiring Diagrams

Plug Type

OUTPUT:

NPN NO-NC Cable S50-P**A-2*-C10-NN S50-P**A-2*-C21-NN S50-P**A-2*-C01-NN S50-P**A-2*-D00-NN

PNP NO-NC Cable S50-P**A-2*-C10-PP S50-P**A-2*-C21-PP S50-P**A-2*-C01-PP S50-P**A-2*-D00-PP

Emitter Cable – – ––

*For plug type replace 2 with 5 e.g. S50-PA-5-B01-NN For sensor cable and accessories see pages 329-332

**For metal type replace P with M e.g. S50-MA-5-C10-PK For Radial Optics 90° Sensing use DEV90 Accessory

299 DAT

»AND STAINLESS STEEL PNP/NPN IP67 & IP69K ATEX II 3dg

Retro-Reflective Polarized Transparents Through Beam Emitter
Non-Polarized Background Suppression Receiver

0.1-5m (R2 Reflector) 0.1-4m (R2 Reflector) 0.1-8m (R2 Reflector) 40-120mm 0-20m 0-20m

12-30VDC 12-30VDC 12-30VDC 12-30VDC 12-30VDC 12-30VDC

Infrared LED 880nm Red LED 660nm Red LED 660nm Red LED 660nm - Infrared LED 880nm

Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* -

Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED

500 Hz 500 Hz 500 Hz 500 Hz 250 Hz -

Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^

Wiring Diagrams M12 Connector ^With Light/Dark input not connected
Cable S15...A01/B01/C11/C31/T01/F01/M01 S15...G01 the Proximity models function in the
S15...A00/B00/C00/C10/F00/D50 S15...G00 light mode, the retroreflex and
through beam models in the Dark
mode. The Light mode can be
selected connecting the Light/Dark
input to +Vdc and the Dark mode
connecting it to the 0Vdc.

S15-PA-2-A00-NK S15-PA-2-B00-NK - - S15-PA-2-F00-NK S15-PA-2-G00-XG

S15-PA-2-A00-PK S15-PA-2-B00-PK - - S15-PA-2-F00-PK

S15-PA-5-A01-NK S15-PA-5-B01-NK S15-PA-5-T01-NK S15-PA-5-M01-NK S15-PA-5-F01-NK S15-PA-5-G01-XG
S15-PA-5-A01-PK S15-PA-5-B01-PK S15-PA-5-T01-PK S15-PA-5-M01-PK S15-PA-5-F01-PK

S15-NA-5-A01-NK S15-NA-5-B01-NK S15-NA-5-T01-NK - S15-NA-5-F01-NK S15-NA-5-G01-XG
S15-NA-5-A01-PK S15-NA-5-B01-PK S15-NA-5-T01-PK - S15-NA-5-F01-PK

*Sensitivity trimmer on M12 Plug Units Only For sensor cable and accessories see pages 329-332

DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN NO-NC IP67

Retro-Reflective Contrast Sensor Through Beam
Non-Polarized Retroreflex for Transparents
Polarized

0.1-5m (R2,R5 reflector*) 4m (R2,R5 reflector*) 0.7-1.7m (R2,R5 reflector*) 10mm 0-20m LIMIT & PRESSURE SWITCHES & SENSORS
10-30VDC 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Infrared LED 880nm Red 660nm Red LED 660nm White LED 400-700nm Infrared LED 880nm
– – – 0.5mm –
– Sensitivity trimmer Sensitivity trimmer Teach-in push-button Sensitivity trimmer
Yellow Yellow/Green (stability) Yellow Yellow/Green/Red Error Yellow/Green (stability)
1kHz 1kHz 1kHz 5kHz 250kHz
Dark on NO / light on NC Dark on NO / light on NC Dark on NO / light on NC Dark with EASYtouch™ Dark on NO / light on NC

S50-P**A-2*-A00-NN S50-P**A-2*-B01-NN S50-P**A-2*-T01-NN S50-P**A-2*-W03-NN S50-P**A-2*-F01-NN
S50-P**A-2*-T01-PP S50-P**A-2*-W03-PP S50-P**A-2*-F01-PP
S50-P**A-2*-A00-PP S50-P**A-2*-B01-PP – – S50-P**A-2*-G00-XG

–– DAT 300

Laser models available on request

DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN IP67

Type DC M18 Ø18 Diffuse Proximity Retro-Reflective Through Beam
Non-Polarized Polarized
S51 SERIES Short Distance Long Distance Receiver Emitter

• Nominal Voltage 10-30VDC
• Output: NO, NPN or PNP
• Output Current: ≤100mA
• Housing Material: PBT (plastic v) Nickel
Plated Brass (metal v)
• Temperature Range: -25 to 55°C
• Flat plastic or cylindrical metal housing
• Cable or M12 connection NPN or PNP
output
•Standard 3 wire connection configuration

Sensing Distance 100mm 400mm 0.1-4m (R5 Reflector) 0.1-3m (R5 Reflector) 20m
DC Supply Voltage
Emission 10-30VDC 10-30VDC 10-30VDC
Setting
Output LED Infrared LED 880nm Infrared LED 880nm Red LED 650nm Infrared LED 880nm
Switching Frequency
Operation Mode – Sensitivity trimmer – Sensitivity trimmer –

–– – Yellow Output LED

500Hz 500Hz 120Hz –

Dark/Light selectable^ Dark/Light selectable^ Dark/Light selectable^

^With Light/Dark input not connected the Proximity models function in the light mode, the retroreflex and through beam models in the

Dark mode. The Light mode can be selected connecting the Light/Dark input to +Vdc and the Dark mode connecting it to the 0Vdc

Metal Housing Version Wiring Diagrams M12 Connector

OUTPUT: Plug Type
NPN Cable
PNP Cable S51-P**A-2*-C10-NK S51-P**A-2*-C01-NK S51-P**A-2*-A00-NK S51-P**A-2*-B01-NK S51-P**A-2*-F00-NK S51-P**A-2*-G00-XG
S51-P**A-2*-C10-PK S51-P**A-2*-C01-PK S51-P**A-2*-A00-PK S51-P**A-2*-B01-PK S51-P**A-2*-F00-PK
*For plug type replace 2 with 5 e.g. S51-PA-5-B01-PK For sensor cable and accessories see pages 329-332
**For metal type replace P with M e.g. S51-MA-5-B01-PK For Radical Optics, replace A with R. E.g. S51-PR-5-B01-PK

MINIATURE PHOTOELECTRIC SENSOR BASIC LINE NPN or PNP NO-NC IP66

Type DC Diffuse Proximity Retro-Reflective Through Beam Through Beam
S41 SERIES Emitter Receiver
Polarized Transparents
• Nominal Voltage 10-30VDC
• Output: NPN or PNP NO-NC
• Output Current: 100mA max.
• Housing Material: PMMA Plastic
• Temperature Range: -25 to 55°C
• Models with trimmer setting
• NPN or PNP output
•Double NO-NC

Sensing Distance 0.2-350mm 0.1-2.5m (R2 Reflector) 0.1-0.7m (R2 Reflector) 0.1-6m 0.1-6m
Supply Voltage 10-30VDC 10-30VDC
LIMIT & PRESSURE SWITCHES & SENSORS Emission Infrared LED 880nm 10-30VDC 10-30VDC 10-30VDC Infrared LED 880nm
Setting Sensitivity trimmer –
Output LED Red/Green Red LED 660nm Red LED 660nm Infrared LED 880nm Red/Green
Switching Frequency 500Hz 500Hz
Operation Mode Dark or Light Sensitivity trimmer Sensitivity trimmer – Dark or Light
Wiring Diagrams
32H x 12W x 20D Yellow/Green Red/Green Red/Green

500Hz 500Hz 500Hz

Dark or Light Dark or Light Dark or Light

Plug Type M8 CONNECTOR M8 CONNECTOR M8 CONNECTOR

OUTPUT: S41-2*-C-P S41-2*-B-P S41-2*-T-P S41-2*-G S41-2*-F-P
PNP NO-NC Cable
NPN NO-NC Cable S41-2*-C-N S41-2*-B-N S41-2-*T-N S41-2*-G S41-2*-F-N

301 *For plug type replace 2 with 5 e.g. S41-5-C-P For sensor cable and accessories see pages 329-332

*For plug and cable use part number CS-B1-02-G-05/03

DAT

PHOTOELECTRIC SENSORS MICROPROCESSOR-BASED TEACH-IN NPN/PNP IP67

Type DC Diffuse Polarized Retro-Reflective Background
Proximity Transparents Suppression
S40 SERIES

• Nominal Voltage 10-30VDC
• Output: NPN or PNP
• Output Current: 100mA max.
• Housing Material: ABS
• Temperature Range: -20 to 60°C
• EASYtouch™ microprocessor teach in
and Remote setting
• Cable or M8 connection
• NPN or PNP

Sensing Distance 0.5-300mm 0.1-2.5m (R2 Reflector) 0.1-7m (R2 Reflector) 15-100mm
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC
Emission Red LED 660nm Red LED 660nm Red LED 660nm
Setting Teach-in button Teach-in push-button Teach-in button
Output LED Yellow/Green Yellow/Green Yellow/Green
Switching Frequency 4kHz 1kHz 1kHz
Operation Mode Dark/light prog. Dark/light programmable Dark/light prog.

M8 Connector Wiring Diagrams

NPN output PNP output S40-x-G

Plug Type

OUTPUT: S40-PR-2*-C03-PH S40-PR-2*-B03-PH S40-PR-2*-T03-PH S40-PR-2*-M03-PH
PNP Cable
NPN Cable S40-PR-2*-C03-NH S40-PR-2*-B03-NH S40-PR-2*-T03-NH S40-PR-2*-M03-NH

*For plug type replace 2 with 5 e.g. S40-PR-5-A03-PH For sensor cable and accessories see pages 329-332

*For plug and cable use part number CS-B1-02-G-05/03 Laser models available on request

DC MINIATURE PHOTOELECTRIC SENSORS NPN/PNP DARK/LIGHT MODE IP67

Type DC Diffuse Proximity Polarized Narrow Beam Proximity Through Beam Set
Retro-Reflective
S3Z SERIES Ø 1mm

• Nominal Voltage 10-30VDC
• Output: NPN or PNP
• Output Current: ≤100mA
• Housing Material: PC/PBT
• Temperature Range: -25 to 55°C

Sensing Distance 0-700mm 0.05-4m (R5 Reflector)* 150mm 15m LIMIT & PRESSURE SWITCHES & SENSORS
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 870nm Red LED 665nm Red LED 665nm Infrared LED 870nm
Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
Output LED Yellow/Green (stability) Yellow/Green (stability) Yellow/Green (stability) –
Switching Frequency 500Hz 500Hz 500Hz 500Hz
Operation Mode Dark or light Dark or light Dark or light Dark or light
Wiring Diagrams
M8 Connector

OUTPUT: S3Z-PR-2*-C11-PL S3Z-PR-2*-B01-PL S3Z-PR-2*-C01-PL S3Z-PR-2*-FG01-PL
PNP Light. Cable Version
PNP Dark. Cable Version S3Z-PR-2*-C11-PD S3Z-PR-2*-B01-PD S3Z-PR-2*-C01-PD S3Z-PR-2*-FG01-PD
NPN Light. Cable Version
NPN Dark. Cable Version S3Z-PR-2*-C11-NL S3Z-PR-2*-B01-NL S3Z-PR-2*-C01-NL S3Z-PR-2*-FG01-NL
Light = NO. Dark = N.C
S3Z-PR-2*-C11-ND S3Z-PR-2*-B01-ND S3Z-PR-2*-C01-ND S3Z-PR-2*-FG01-ND

*For plug type replace 2 with 5 e.g. S3Z-PR-5-C01-PL For sensor cable and accessories see pages 329-332

*For plug and cable use part number CS-B1-02-G-05/03 Laser models available on request

DAT 302

ECONOMY DC MINIATURE SENSOR PNP/NPN IP67

Type DC Diffuse Proximity Long Distance Fixed Focus
S100 SERIES Medium Distance

• Nominal Voltage: 10-30VDC
• Output: NPN or PNP
• Output Current: 100mA
• Temperature Range: -25 to 55°C
• Housing Material: ABS (housing) /
PMMA (indicators cover)
• Cost Effective

Sensing Distance 300mm 500mm 70mm
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC
Emission Red LED 632nm Red LED 632nm Red LED 632nm
Switching Frequency 500 Hz 500 Hz 500 Hz
Operation Mode Dark/Light input Dark/Light input Dark/Light input
Plug Type Dimensions

Anti tampering sensor

Two threaded
front mounting
holes

OUTPUT: Two slotted rear
mounting holes

PNP Cable S100-PR-2*-C00-PK S100-PR-2*-C10-PK S100-PR-2*-D00-PK
NPN Cable S100-PR-2*-C00-NK S100-PR-2*-C10-NK S100-PR-2*-D00-NK

Type DC *For plug type replace 2 with 5 e.g. S50-PA-5-B01-NN Through Beam
S100 SERIES For sensor cable and accessories see pages 329-332

• Nominal Voltage: 10-30VDC Retro-Reflective Background
• Output: NPN or PNP Suppression
• Output Current: 100mA Non-Polarized Polarized
• Temperature Range: -25 to 55°C
• Housing Material: ABS (housing) /
PMMA (indicators cover)
• Cost Affective

LIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 8m 6m 30-100mm 12m
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 860nm Red LED 632nm Red LED 632nm Infrared LED 860nm
Switching Frequency 500 Hz 500 Hz 500 Hz 250Hz
Operation Mode Dark/Light input Dark/Light input External Teach-In Dark/Light input
Wiring Diagrams

For plug and cable, use code CS-BI-02-G-05/3

PNP Cable S100-PR-2*-A00-PK S100-PR-2*-B10-PK S100-PR-2*-M00-PH S100-PR-2*-FG00-PK
S100-PR-2*-B10-NK S100-PR-2*-M00-NH S100-PR-2*-FG00-NK
NPN Cable S100-PR-2*-A00-NK
DAT
303

DC ADVANCED PHOTOELECTRIC SENSORS NPN/PNP IP67 ATEX

Type DC Diffuse Proximity Retro-Reflective Through Beam
S8 SERIES Polarized
Transparents

• Nominal Voltage 12-30VDC 500mm 5m (R2 Reflector) 50-800mm** 25m
• Output: NPN or PNP NO 12-30VDC
• Output Current: ≤100mA max. Red LED 660nm 12-30VDC 12-30VDC
• Housing Material: ABS Mono turn sensitivity adj. trimmer
• Temperature Range: -10 to 55°C Yellow/Green Red LED 660nm Red LED 660nm
• Excellent performances within 500us
small dimensions (14x42x25mm) 1kHz Mono turn sensitivity adj. trimmer Set push button (T53) Mono turn sensitivity adj. trimmer
• Compact Dimensions Dark/Light selectable
• Very High Resolution Yellow/Green Yellow/Green
• High performance for most M8 Connector
challenging applications 500us 250us 500us

Sensing Distance 1kHz 2kHz 1kHz

DC Supply Voltage Dark/Light selectable Dark/Light selectable

Emission M8 Connector - B01/T51 Version - T53 Version M8 Connector
- F01 Version
Setting

Output LED

Response Time

Switching Frequency

Operation Mode
Wiring Diagrams

- G00 Version

OUTPUT: S8-PR-5-C01-PP S8-PR-5-B01-PP S8-PR-5-T51**-PP S8-PR-5-F01-PP
PNP M8 Plug*
NPN M8 Plug* S8-PR-5-C01-NN S8-PR-5-B01-NN S8-PR-5-T51**-NN S8-PR-5-F01-NN
Through Beam Emitter
- - - S8-PR-5-G00-XG

*For M8 plug and cable see pages 329-332. Stainless Steel models available on request

**For retro-reflective for transparent units with 2000mm sensing distance replace 1 with 3 e.g. S8-PR-5-T53-PP

*For plug and cable use part number CS-B1-02-G-05/03

Type DC Clear and Shiny Detection Background Suppression Contrast
S8 SERIES

• Nominal Voltage 12-30VDC
• Excellent performances within
small dimensions
• Compact Dimensions
• Very High Resolution

Sensing Distance 100-300mm 50-150mm 50-300mm 20-200mm 9mm
DC Supply Voltage 12-30VDC
Emission 12-30VDC 12-30VDC Blue, Green, Red
Setting Teach-in push-button
Output LED Red LED 660nm Red Laser Red LED 660nm Red Laser Yellow/Green LIMIT & PRESSURE SWITCHES & SENSORS
Response Time 50us
Switching Frequency 8-turn distance adj. trimmer, Teach 8-turn distance adj. trimmer 10kHz
Operation Mode Dark/Light selectable
Wiring Diagrams Yellow/Green Yellow/Green

OUTPUT: 1ms 1ms 100us
PNP M8 Plug*
NPN M8 Plug* 500Hz 500Hz 5kHz

Remote Dark/Light selectable Dark/Light selectable

M8 Connector M8 Connector -
PR Version

S8-PR-5-M53-PP S8-PH-5-M53-PP S8-PR-5-M01-PP M8 Connector -
- - S8-PR-5-M01-NN PH Version
*For M8 plug and cable see pages 329-332
S8-PH-5-M01-PP S8-PR-5-W03-PP
S8-PH-5-M01-NN S8-PR-5-W03-NN

All the safety electrical and mechanical regulations and laws have to be respected during sensor functioning. The sensor has to be protected
against mechanical damages. Place the given labels in a visible position close to the laser emission. • Do not look directly into the laser beam! •
Do not point the laser beam towards people! • These sensors are not to be used for safety applications!

DAT 304

THE MOST COMPLETE UNIVERSAL SENSOR IN A COMPACT 50X50MM HOUSING IP67

Type DC Diffuse Proximity Retro-Reflective Through Beam
S62 SERIES C01 C11
Non-Polarised Polarised Receiver Emitter

• New better modern look

50x50 housing

• Better performance

• Retroreflective up to 13m
• VDC and VAC Models

Sensing Distance 0-900mm 0-200cm 0.1-13m (R2,R5 reflector) 0.1-8m (R2,R5 reflector) 0-25m 0-25m
Supply Voltage
Emission 10-30VDC / 24-240VAC/24-60VDC**
Setting
Output LED RED 640nm Red 640nm
Output
Mono-turn sensitivity adjustment trimmer. Mono-turn light/dark trimmer (S62-RX/PN)
Output Current
Saturation Voltage OUTPUT LED (yellow) / STABILITY LED (green) POWER ON LED (green)
Response Time
Switching Frequency NPN/PNP (S62-PN)dc vers. NPN or PNP NO/NC Test + Test -
Mechanical Protection (S62-PP/NN)dc vers. Relay SPDT 250VAC/30VDC (S62-RX)
Housing Material
Operating Temperature S62-PA-2/5, S62-M version: ≤100mA (overload and overvoltage protection), S62-PA-1-RX version: 2A Max (resist load)
Dimensions ≤2v S62-PA-2/5 VDC vers

500us max, 25ms (Relay version) 500us max, 25ms (Relay version) 1ms, 25ms (Relay version)

1kHz, 20Hz (Relay version) 2kHz, 20Hz (Relay version) 50kHz, 20Hz

IP67 IP67 IP67

ABS ABS ABS

-10 to 55C° -10 to 55C° -10 to 55C°

OUTPUT: S62-PA-2*-C01-NN S62-PA-2*-C11-NN - S62-PA-5-B01-NN S62-PA-2*-F01-NN
NPN NO-NC Cable
PNP NO-NC Cable S62-PA-2*-C01-PP S62-PA-2*-C11-PP - S62-PA-2*-B01-PP S62-PA-2*-F01-PP S62-PA-2*-G00-XG
NPN/PNP Cable
Relay Cable** S62-PA-2*-C01-PN S62-PA-2*-C11-PN S62-PA-2*-A01-PN S62-PA-2*-B01-PN S62-PA-2*-F01-PN
S62-PA-1-C01-RX S62-PA-1-C11-RX S62-PA-1-A01-RX S62-PA-1-B01-RX S62-PA-1-F01-RX S62-PA-1-G00-XX
Wiring Diagrams
LIMIT & PRESSURE SWITCHES & SENSORS *For plug type replace 2 wih 5 e.g. S62-PA-5-C01-NN Laser models available on request

For sensor cable and accessories see pages 329-332

DC Models AC Models**

S62-PA-2/5-PN S62-PA-1-A/B/C/F S62-PA-1-G

S62-PA-2/5-PP/NN S62-PA-2/5-G S62-PA-5...PP/NN (M12 connector)

305 DAT

BACKGROUND SUPPRESSION 50X50 COMPACT PNP/NPN IP67

Type DC Background Suppression
S62 SERIES

• Nominal Voltage 10-30VDC
• Units with time adjustment
trimmer
• Background suppression
from 3cm-2m

Sensing Distance 30-300mm 60-600mm 60-1200mm 200-2000mm
DC Supply Voltage
Emission 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Setting
Output LED RED 660nm Infrared (880nm)
Output
Output Current Muliti Turn distance adjustment trimmer / Timer adjustment trimmer (S62-M05/M15/M25/M35). Dark/light selection mono turn trimmer (S62-M01/M11-PN)
Saturation Voltage
Response Time OUTPUT LED (yellow) / STABILITY LED (green) (S62-M0/M1) POWER ON LED (green) (S62-M2/M3)
Switching Frequency
Mechanical Protection NPN or PNP NO/NC (S62-PP/NN)
Housing Material
Operating Temperature 100mA (overload and voltage protection)

Dimensions ≤2v ≤2v ≤2v ≤2v
500us (S62-M0/M1), 1ms (S62-M2) 1,5ms(S62-M3)

1kHz (S62-M0/M1), 500Hz (S62-M2), 330Hz (S62-M3)

IP67 IP67 IP67 IP67

ABS ABS ABS ABS

-10 to 55C° -10 to 55C° -10 to 55C° -10 to 55C°

OUTPUT: S62-PA-2-M01-PP S62-PA-2-M11-PP S62-PA-2-M21-PP S62-PA-2-M31-PP
PNP NO-NC Cable
NPN NO-NC M12 Plug S62-PA-5-M01*-NN S62-PA-5-M11*-NN S62-PA-5-M21*-NN S62-PA-5-M31*-NN
PNP NO-NC M12 Plug
S62-PA-5-M01*-PP S62-PA-5-M11*-PP S62-PA-5-M21*-PP S62-PA-5-M31*-PP
Wiring Diagrams
* For units with timer adjustment trimmer change 1 to 5 e.g. S62-PA-5-M01-NN to S62-PA-5-M05-NN

For sensor cable and accessories see pages 329-332 Laser models available on request

S62-PA-2/5...PN S62-PA-2...PP/PN S62-PA-5...PP/PN (M12 connector)

Detection Diagrams LIMIT & PRESSURE SWITCHES & SENSORS

DAT 306

MAXI SENSOR FOR CRITICAL APPLICATIONS VAC/VDC IP67

Type AC/DC Diffuse Proximity Polarized Background Through Beam
S300-PR SERIES Retro-Reflective Suppresion Receiver Emitter

• Excellent Optical Performances
• Heavy duty industrial plastic housing
• Distance trimmer clutch for mechanical
background suppression models
• Units with defogging functions

Sensing Distance 5m 22m 2.5m 60m
Supply Voltage
Emission 24-240VAC / 12-240VDC
Setting
Infrared LED 940nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm
Output LED Mono-turn Mono-turn Multi-turn Mono-turn Sensitivity Trimmer

Output Sensitivity Trimmer Sensitivity Trimmer Adjustment Screw
Output current
Saturation Voltage Output LED (Yellow) Stability LED (GREEN) Output Yellow/ Power On LED Green
Response Time Stability Green
Switching Frequency
Mechanical Protection NPN & PNP open collector. Relay SPDT electromagnetic relay 250VAC, 30VDC*
Housing Material 100mA (Resistive Load). 3A (Resistive Load)*
Connections <2.4V Max NPN & PNP only
Operating Temperature
20ms (AC), 1ms (S300-C, S300-B, S300-F/G) (DC) 2ms (S300-M) (DC)
25Hz (AC), 500Hz (S300-B, S300-C, S300-F/G) (DC), 250Hz (S300-M) (DC)

IP67
PBT (30% Fibre-reinforced Glass)
Terminal Block (Recommended Cable Diameter 8mm – 10mm) (AC), 4-Pin M12 Plug (DC)

-40º to 55ºC

Dimensions M12 Connector Version

OUTPUT:

Relay NO/NC ADJ, No Timer S300-PR-1-C01-RX S300-PR-1-B01-RX S300-PR-1-M01-RX S300-PR-1-F01-RX S300-PR-1-G00-EX***†
Relay NO/NC ADJ, Timer S300-PR-1-C06-RX*** S300-PR-1-B06-RX*** S300-PR-1-M06-RX*** S300-PR-1-F06-RX***

NPN & PNP M12 Plug ADJ, No Timer S300-PR-5-C01-OC S300-PR-5-B01-OC S300-PR-5-M01-OC S300-PR-5-F01-OC
NPN & PNP M12 Plug ADJ, Timer S300-PR-5-C06-OC S300-PR-5-B06-OC S300-PR-5-G00-EX***†

S300-PR-5-M06-OC S300-PR-5-F06-OC

*24-240VAC/12-240VDC AC voltage untis only. ***For defogging functions, add -M to part number. †No ADJ, No Timer, No Outputs

For sensor cable and accessories see pages 329-332

LIMIT & PRESSURE SWITCHES & SENSORS Wiring Diagrams M12 Connector (only DC models)
Connections G
Connections B, C, M , F

M12 Connector (only DC models)

Timing Functions Indicators

Four selectable timing functions: one shot, ON DAT
delay, OFF delay, ON/OFF delay and normal
mode. Trimmer adjustment of the functions is
available. The timing functions can be
particularly useful in applications where the
output signal pulse has to be modified.

307

ADVANCED COST EFFECTIVE MAXI SENSORS VAC/VDC IP67

Type AC/DC Diffuse Proximity Retro-Reflective Background Through Beam
S300-PA SERIES Non-Polarized Polarized Suppresion Receiver Emitter

• Excellent cost/performance ratio
• Terminal block for both VDC and
VAC/VDC free voltage versions
• Sturdy industrial plastic housing IP67

Sensing Distance 5-200cm 01.-15m 0.1-10m 20-200cm 0-50m
Supply Voltage
Emission 12-30VDC or 24-240VAC / 12-60VDC Infrared LED 880nm
Setting Infrared LED 940nm Infrared LED 880nm Red LED 660nm Infrared LED 880nm

Output LED 7-Turns adjustment screw. Mono-turn Sensitivity Trimmer
Output
Output Current Mono-turn Sensitivity Trimmer. Dark/Light Dip Switch mode On Dark/Light Dip Switch. Dip Dark/Light Dip Switch.
Saturation Voltage delay/Off delay/Single pulse (One-Shot)(S300-X06 version only)
Response Time Switch mode On delay/Off Dip Switch mode On
Switching Frequency delay/Off delay/On-Off
Mechanical Protection delay/On-Off delay/Single delay/Single pulse
Housing Material pulse (One-Shot (One-Shot)(S300-X06
Connections
Operating Temperature (S300-X06 version only) version only)
Dimensions
OUTPUT LED (Yellow) / STABILITY LED (Green) / POWER ON LED (Green)(S300-G version)

NPN & PNP open collector. Relay SPDT electromagnetic relay 250VAC, 30 VDC*

100mA (resistive load). 3A (resistive load)*

<2.4V Max NPN & PNP only

1ms (DC) 25ms (AC) 2ms (S300-G version)

500Hz (DC) 20Hz (AC) 250Hz (S300-G version)

IP67

PBT 30% fibre-reinforced glass

Terminal Block (recommended cable diameter 8-10mm)

-20 to 55°C

100,4 96

OUTPUT: 27 40 50 5589.7S300-PA-1-B01-RX S300-PA-1-M01-RX S300-PA-1-F01-RX S300-PA-1-G00-EX**
Relay NO/NC ADJ, No Timer 67.5 S300-PA-1-B06-RX S300-PA-1-M06-RX S300-PA-1-F06-RX
Relay NO/NC ADJ, Timer S300-PA-1-C01-RX S300-PA-1-A01-RX
NPN & PNP ADJ, No Timer S300-PA-1-C06-RX S300-PA-1-A06-RX LIMIT & PRESSURE SWITCHES & SENSORS
NPN & PNP ADJ, Timer
S300-PA-2-C01-OC S300-PA-2-A01-OC S300-PA-2-B01-OC S300-PA-2-M01-OC S300-PA-2-F01-OC
Wiring Diagrams S300-PA-2-C06-OC S300-PA-2-A06-OC S300-PA-2-B06-OC S300-PA-2-M06-OC S300-PA-2-F06-OC S300-PA-2-G00-EX**

*24-240VAC/24-60VDC AC voltage untis only.

**No ADJ, No Timer, No Outputs.

Connections G Connections A, B, C, M, F Timing Functions

AC Modles DC Modles AC Modles DC Modles Five selectable timing functions: one shot, ON delay, OFF
delay, ON/OFF delay and normal mode. Trimmer adjustment
of the functions is available.The timing functions can be
particularly useful in applications where the output signal
pulse has to be modified.

DAT 308

COMPLETE RANGE OF CONTRAST, REGISTRATION MARK,»

Type DC TLU Series TL46 Series

Trimmer Basic

• Nominal Voltage 10-30VDC
• World leading mark sensors
• Red/green or white LED
emission
• Rotatable connector

Sensing Distance 6-12mm 6-12mm 6-12mm
DC Supply Voltage
Setting 10-30VDC 10-30VDC 10-30VDC

Output LED Teach-in with 2 Pushbuttons / Remote Multi Turn Digital Trimmer for an easy and
Automatic
Emission
Spot quick adjustment of the switching threshold
Spot Dimension
Output Red Output / Green Ready Yellow Output / Green Ready / Orange Yellow Output / Green Ready
Analogue Output Indicator Arrows
Output Current
Saturation Voltage Red / Green LED White 400-700nm RGB LED
Response Time
Switching Frequency Vertical Horizontal Vertical Vertical Horizontal
Operation Mode
Mechanical Protection 1.5 x 5mm 1.5 X 5mm 1.5 X 5mm
Housing Material
Operating Temperature NPN and PNP NPN and PNP Programmable NPN or PNP Programmable
Connections
Dimensions Yes 0-5VDC 0.5-5.5VDC on white target 0.5-5.5VDC on white target

200mA Max <100mA Max <100mA Max

1V max (NPN Version) 2V Max (PNP Version) < 2V < 2V

50us 25us 33us

10KHz 20KHz 15KHz

Automatic Dark/Light Selection Dark/Light with switch Dark/Light selectable

IP67 IP67 IP67

ZAMA Aluminium Aluminium
-10o to 55oC -10o to 55oC -10o to 55oC

3m 6.1mm Shielded Cable *M12 4-Pole connector *M12 5-Pole Connector *M12 5-Pole Connector

M5
M5

OUTPUT:

NPN & PNP (Programmable) - - - TL46-W-815 TL46-W-815L
- -
NPN Cable TLU-011** TLU-011**L TL46-A-425 - -
- -
LIMIT & PRESSURE SWITCHES & SENSORS PNP Cable TLU-111** TLU-111**L TL46-A-415 - -

NPN-NO RS485 - - -

PNP-NO RS485 - - -

**For plug type replace 1 with 5 e.g. TLU-115

For sensor cable and accessories see pages 329-332

Wiring Diagrams Trimmer Verion

309 Basic Standard
and Enhanced
Versions
** For plug and cable
use part number
CS-A1-03-G-03

DAT

TL46 Series »COLOUR AND LUMINESCENCE SENSORS IP67
Standard
Luminescence LD46 Series Colour S65-V Series

Enhanced

RGB

6-12mm 6-12mm 10-20mm 5-45mm
10-30VDC 10-30VDC 15-30VDC 10-30VDC

Automatic / Manual / Remote Automatic / Manual / Remote / Dynamic Manual using +, - and SET push buttons SET & SEL push buttons

Yellow Output / Green Ready / Orange Delay/ Yellow Output / Green Ready / Orange Delay/ Yellow Output / Green Ready / Orange Delay/ 4 Digit Display Green active Outputs, yellow

Orange Keylock / 5 Segment Bargraph Orange Keylock / 4 Digit Display Orange Keylock / 5 Segment Bargraph or function output

RGB LED RGB LED LED UV, 375nm White LED 400-700nm

Vertical Horizontal Vertical Horizontal

1.5 X 5mm 1.5 X 5mm 2 x 8mm at 10mm 4mm at 20mm

NPN or PNP Programmable NPN or PNP Programmable 1 x NPN 1 x PNP 3 x PNP or NPN

Yes 0-5VDC Yes 0-5VDC

<100mA Max <100mA Max <100mA Max <100mA Max

< 2V < 2V < 2V < 2V

25us 17us 250us 335us

20KHz 30KHz 2KHz 1.5KHz

Dark/Light Selectable Dark/Light Selectable Light C or C+I Independant for each channel

IP67 IP67 IP67 IP67

Aluminium Aluminium Aluminium ABS
-10o to 55oC -10o to 55oC -10o to 55oC -10o to 55oC

*M12 5-Pole Connector *M12 5-Pole Connector *M12 - 5 Pole Connector *M12 - 8 Pole Connector

M5
M5

TL46-WL-815 TL46-WL-815L TL46-WFL-815 TL46-WFL-815L LD46-UL-715 -
- - -
- - -- - -
- - S65-PA-5-V09-NNNZ
- - -- - S65-PA-5-V09-PPPZ LIMIT & PRESSURE SWITCHES & SENSORS

-- - M12 Connector

-- -

For sensor cable and accessories see pages 329-332

** For plug and cable use part *Available only for version with RS485
number CS-A1-03-G-03 serial connection (S65-PA-5-V09-xxxZ)
** For plug and cable use part
DAT number CS-A1-06-B-03

310

Type DC M18 DC LASER PNP/NPN NO-NC IP67 Laser Emitter

S50 SERIES Laser Diffuse Proximity Laser Retro-Reflective Laser Receiver 0-60m
10-30VDC
• Output: NPN or PNP NO-NC Red Laser 650nm²
• Output Current: ≤100mA max. Sensitivity trimmer
• Response Time 333µs Green/Yellow
• Housing Material: PBT 1.5kHz
• Temperature Range: -10 to 50°C

Sensing Distance 0-350mm 0-16m 0-60m
Supply Voltage 10-30VDC 10-30VDC 10-30VDC
Emission Red Laser 650nm² Red Laser 650nm² Red Laser 650nm²
Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
Output LED Green/Yellow Green/Yellow Green/Yellow
Switching Frequency 1.5kHz 1.5kHz 1.5kHz
Dimensions

OUTPUT: S50-PL-5-C01-PP S50-PL-5-B01-PP S50-PL-5-F01-PP –
PNP NO-NC M12 S50-PL-5-C01-NN S50-PL-5-B01-NN S50-PL-5-F01-NN –
NPN NO-NC M12 – – – S50-PL-5-G00-XG
Emmitter
Wiring Diagrams Laser Emitter

For Sensor Cables and
accessories see page 329-332

Type DC DC LASER PNP/NPN NO-NC IP67

S60 SERIES Laser diffuse proximity Laser Retro-Reflective Laser Receiver

• Output: NPN or PNP NO-NC
• Output Current: ≤100mA max.
• Response Time 250µs
• Housing Material: ABS
• Temperature Range: -10 to 50°C

LIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 0-600mm 0.1-20m 0-60m 0-60m
Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Red Laser 650nm² Red Laser 650nm² Red Laser 650nm² Red Laser 650nm²
Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
Output LED Green/Yellow Green/Yellow Green/Yellow Green/Yellow
Switching Frequency 2kHz 2kHz 1.5kHz 1.5kHz
Dimensions

OUTPUT: S60-PL-5-C01-PP S60-PL-5-B01-PP S60-PL-5-F01-PP –
S60-PL-5-C01-NN S60-PL-5-B01-NN S60-PL-5-F01-NN –
PNP NO-NC M12 – – – S60-PL-5-G00-XG
NPN NO-NC M12
Emitter DAT
Wiring Diagrams

For Sensor Cables and
accessories see pages 329-332

311

ECONOMY U-SHAPE SENSORS 2mm SLOT SENSORS IP65

SR31 Series 30mm SR22 Series 1mm Slot Width 2mm 2mm
SR21 Series

Fork Slot • High 25kHz switching frequency

• Output Current: 200mA max. • Detection of semi-transparent
• Switching Frequency 10kHz
labels

• Detection of register marks on

transparents

• NPN and PNP output

• Output: NPN & PNP

• Output Current: 100mA Sci

Protection

• Housing Material: ZAMA

• Temperature Range:

-20 to 60°C

DC Supply Voltage 10-30VDC 24VDC DC Supply Voltage 10-30VDC 10-30VDC
Setting
Output LED Multi-turn Sensitivity Trimmer Trimmer Emission Infrared LED 880nm Green LED 535nm
Output
Operation Mode Red Output Red Output Setting Auto Set push-button Auto Set push-button
Housing Material
Wiring Diagrams NPN or PNP NPN & PNP Resolution 0.5mm 0.5mm

Dark/Light Configurable Dark and Light Output LED Yellow Yellow

ZAMA Aluminium Operating Mode Light/Dark Light/Dark

Wiring Diagrams

Light Mode Dark Mode

OUTPUT: For plug and cable use part number CS-B1-02-G-05/03
For sensor cable and accessories see pages 329-332
NPN & PNP (programmable) SR31 –
SR22-5-IR-OD
Dark Mode – SR22-5-IR-OL OUTPUT:
PNP & NPN M8
Light Mode – SR21-IR SR21-RG

ULTIMATE PRECISION FORK TYPE PHOTOELECTRIC SENSOR PNP/NPN MODE

Fork Width IP65 30mm 50mm 80mm 120mm

SRF SERIES 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Red LED 640nm² Red LED 640nm² Red LED 640nm² Red LED 640nm²
• Nominal Voltage 10-30VDC Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
• Output: NPN or PNP 0.3mm 0.5mm 0.5mm 0.8mm
• Output Current: 200mA Sci Protection Red LED Red LED Red LED Red LED
• Switching Frequency: 1.5kHz 333µs 333µs 333µs 333µs
• Housing Material: Anodised Aluminium Light/Dark Light/Dark Light/Dark Light/Dark
• Temperature Range: -10 to 60°C
• High resolution with visible red LED M8 Connector
emission
• Sensitivity adjustment trimmer
• Sturdy industrial metal housing with
glass lenses

DC Supply Voltage

Emission LIMIT & PRESSURE SWITCHES & SENSORS

Setting

Resolution

Output LED

Response Time

Operation Mode

Wiring Diagrams

OUTPUT: SRF-30-5-P SRF-50-5-P SRF-80-5-P SRF-120-5-P
PNP NO-NC Selectable M8
NPN NO-NC Selectable M8 SRF-30-5-N SRF-50-5-N SRF-80-5-N SRF-120-5-N

For plug and cable use part no. CS-B1-01-G-05 (axial) For sensor cable and accessories see pages 329-332

Lazer models available on request

DAT 312

SLOT SENSORS IP65 ULTRASONIC FORK SENSOR IP54

Slot Sensor SR23 Series 5mm Slot Sensor SRX3 Series 3mm
SR23 SERIES SRX3 SERIES For Transparent Label Detection

• Setting: Auto Set Push-Button
• Output: NPN & PNP

For Sensor Cables and 12 kHz 12 kHz Switching Speed 500Hz
accessories see pages 10-30VDC 10-30VDC DC Supply Voltage 10-30VDC
329-332 Infrared LED 850nm Infrared LED 850nm Emission Ultrasonic
0.5mm 0.5mm Max tape Speed 300m/min
Switching Speed Yellow. Green (Ready) Yellow. Green (Ready) Settings Dynamic/Static Teach-in
DC Supply voltage 100mA 100mA Output LED
Emission 2v 2v Output Current Yellow
Resolution 40us 40us Output 250mA
Output LED class 2 class 2 Response Time PNP/NPN
Output current Zinc Alloy Zinc Alloy Housing Material 1ms
Saturation voltage -25° to 55°C -25° to 55°C Ingress Protection Aluminium
Response Time 2m Cable M8 4-pole Connections IP54
Electrical Protection M12 5-Pole Connector M8 4-Pole Connector
Housing Material Cable M8 Connector Wiring Diagrams
Operating temperature M12 Connector - 5 Pin M8 Connector - 8 Pin
Connection

Wiring Diagrams

OUTPUT: SR23-2-IR-NH SR23-5-IR-NH OUTPUT: SRX3-5-US-M12-PNH SRX3-6-US-M8-PH
NPN SR23-2-IR-PH SR23-5-IR-PH PNP/NPN Dynamic SRX3-5-US-3-M12-PNH SRX3-6-US-3-M8-PH
PNP PNP/NPN Static

ULTRASONIC SENSORS FOR MEASUREMENT AND INSPECTION IP67

Type DC M18 M30 M50
US SERIES

• Nominal Voltage: 10-30VDC
• Output: NPN & PNP / 0-10VDC /
4-20mA
• Output Current: 100mA max.
• Complete Range

Sensing Distance 30-300mm 100-1000mm 200-2000mm 0.2-8m
Setting Teach-in Or Remote Input Teach-in Push button / Remotely /
Analogue Push Button
Output LED Yellow-Green Output / Red Power Yellow Output / Green Power ON / Green Power On / Red Signal /
Red Signal Yellow, Red Output
LIMIT & PRESSURE SWITCHES & SENSORS Housing Material Polyester PBT ABS Polycarbonate
Operating Temperature -25° to 55°C -40° to 70°C -20° to 70°C
Connections M12 5-pole Connector M12 4-pole Connector M12 5-pole Connector
Wiring Diagrams
M12 4-POLE CONNECTOR M12 5-POLE CONNECTOR
Analogue Analogue

NPN Output
PNP Output

Digital Digital

OUTPUT:

NPN & PNP US18-PA*-5-N03-OH US30-PR-5-N13-OH US30-PR-5-N23-OH US50-PR-5-N43-OH

Analogue Output 0 - 10 VDC US18-PA*-5-N03-VH US30-PR-5-N13-VH US30-PR-5-N23-VH US50-PR-5-N43-IVH

Analogue Output 4 - 20 mA US18-PA*-5-N03-IH US30-PR-5-N13-IH US30-PR-5-N23-IH (0-10V / 4-20mA Configurable Output)

* For radial type replace A with R e.g. US18-PR-5-N03-OH For sensor cable and accessories see pages 329-332

313 DAT

TIME OF FLIGHT LASER MEASUREMENT DISTANCE SENSORS

Type DC Analogue Distance Analogue Distance Analogue Distance Analogue Distance Analogue Distance
S80 SERIES
S80 Series S80 Series S80 Series S80 Series S81 Series Cost Effective

Distance 0.3-4m 0.3-7m 0.3-20.3m (on R80 reflector) 0.3-100.3m (on R80 reflector) 0.3-4m
DC Supply Voltage
Digital Resolution 15-30VDC 15-30VDC 15-30VDC 15-30VDC 24VDC +/-20%
Linearity
Switching Frequency 0.9mm 0.4mm 0.6mm 6mm
Light Emission
Response Time 0.3% 0.3% 0.25% 0.15% <1%
Serial Interface
Settings 100Hz(normal)/500Hz(fast) 100Hz 100Hz(normal)/500Hz(fast) 100Hz(normal)/500Hz(fast) 80Hz
Output
Red Laser cl.2 Red Laser cl.2 Red Laser cl.2 Red Laser cl.2 Red Laser 665nm, cl.2
Contact
Connection 5ms(normal)/1ms(fast) 5ms 5ms(normal)/1ms(fast) 5ms(normal)/1ms(fast) 5ms
Electrical Protection
Housing Material RS485 RS485 RS485 RS485 -
Ingress Protection
Operating Temperature Teach-in push-button Teach-in push-button Teach-in push-button Teach-in push-button Teach-in push-button
Dimensions
2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2PNP or NPN outputs

1PNP or NPN alarm output

(only S81...M) 1analogue

0-10V output (S81...Y)

NO NO NO NO -

M12 8-pole connector M12 8-pole connector M12 8-pole connector M12 8-pole connector M12 5-pole connector

Class 2 Class 2 Class 2 Class 2 Class 2

Aluminium Aluminium Aluminium Aluminium ABS

IP67 IP67 IP67 IP67 IP67

-10° to 50°C -10° to 50°C -10° to 50°C -10° to 50°C -10° to 50°C

S80 S81

OUTPUT:

2 x PNP 4 - 20mA S80-MH-5-Y09-PP*IZ S80-MH-5-YL09-PP*IZ S80-MH-5-Y19-PP*IZ S80-MH-5-Y29-PP*IZ -
- - S81-PL-5-M03-PP*C
2 x PNP 1 x PNP Alarm B- ackground suppression - - - S81-PL-5-Y03-PP*V
- - S81-PL-5-Y03-PPVK
2 x PNP 0-10V Analogue - - LIMIT & PRESSURE SWITCHES & SENSORS
S80L-Y S81-M S81-Y
2 x PNP Scalable 0-10V Analogue - -

Wiring Diagrams *For NPN replace PP with NN

E.g. S80-NG-5-Y09-NN

Detection Diagrams For plug and cable use part no. S81 Series
CS-A1-06-B-03.Use only R80 reflector

S80 Series

DAT 314

DC FIBRE OPTIC AMPLIFIERS AND CABLES IP65 DIN RAIL

Type DC Through Beam + Proximity Through Beam + Proximity Through Beam + Proximity

S7 SERIES

• 10 bit resolution models with 500µs response for
high operating distances
• 12 bit resolution models with 50µs response and
4 digit display for high speed
• Cost-effective models with multiturn trimmer
adjustment
• EASYtouch™ push-button setting with remote
control, keylock and output delay
• Ultra-thin housing with CLEARLOCK™ patented
fibre fixing system

Switching Frequency 1KHz 5KHz 10KHz
Sensing Distance 100mm Prox. 300mm Through Beam 50mm Prox. 300mm Through Beam 25mm Prox. 75mm Through Beam
DC Supply Voltage 12-24VDC ±10% 12-24VDC ±10% 12-24VDC ±10%
Emission Red LED 670nm Red LED 670nm White LED 460-630nm
Setting Teach-in push-button Teach-in push-button Teach-in push-button
Output LED Yellow/Green/Red error Yellow/Green/Red error Yellow/Green/Red error
Output PNP or NPN PNP or NPN PNP or NPN
Contact NO NO NO
Output current ≤100ma ≤100ma ≤100ma
Saturation Voltage ≤2V ≤2V ≤2V
Response Time 500µS 100µs 500µs
Timing Function 20ms minimum out ON 20ms minimum out ON 20ms minimum out ON
Operation Mode light with EASYtouch™ light with EASYtouch™ light with EASYtouch™
Plug Type
Wiring Diagrams

OUTPUT: NPN output PNP output

PNP NO M8 Plug S7-6-E-P – –
– –
NPN NO M8 Plug S7-6-E-N S7-5-E-P –
S7-5-E-N –
PNP NO M8 Plug Dispaly – S7-2-E-P S7-1-E-P
S7-2-E-N S7-1-E-N
NPN NO M8 Plug Display –

PNP NO Cable Display –

NPN NO Cable Display –

For plug and cable use part number CS-B1-02-G-05/03

Fibre Optic Cables Stainless Steel Protective Metal Sheath 2m

Optic Function Terminal/Tips Fibre Type Length Part Number Part Number Suitable Fibres

Coaxial Proximity M6 x 1mm Standard 1mm 2m OF-36-ST-20 AF-7 M6 x 0.75mm fibres OF-42-xx
OF-18-ST-10
Proximity M6 x 1mm Standard 1mm 1m OF-22-ST-20 AF-9 M4 x 0.7mm fibres OF-43-xx**
OF-26-TN-10
LIMIT & PRESSURE SWITCHES & SENSORS Proximity M6 x 1mm* Standard 1mm 2m OF-42-ST-20
OF-42-HP-20
Proximity M3 x 0.5mm Thin 0.5mm 1m OF-19-ST-10
OF-23-ST-20
Proximity M6 x 0.75mm Standard 1mm 1m OF-25-TN-10
OF-43-ST-20
Proximity M6 x 0.75mm High Efficiency 1.5mm 2m OF-43-HP-20

Through Beam M4 x 0.7mm Standard 1mm 1m

Through Beam M4 x 0.7mm* Standard 1mm 2m

Through Beam M2 x 0.4mm Thin 0.5mm 1m

Through Beam M4 x 0.7mm Standard 1mm 1m AF-7 Dimensions

Through Beam M4 x 0.7mm High Efficiency 1.5mm 2m AF-9 Dimensions

Application Fibre Optics ** 2 Sheaths have to be ordered for both the emitter-receiver fibres

Optic Function Terminal/Emission Fibre Length Part Number

Through Beam Axial, 16 Beam Array 2m OFA-1-AE-20
Through Beam Radial, 16 Beam Array 2m OFA-1-AS-20
Proximity Axial, 32 Beam Array 2m OFA-2-AE-20
Proximity Radial, 32 Beam Array 2m OFA-2-AS-20

* A bendable stainless steel extension 90mm long protrudes from the threaded optic head

315 DAT

PHOTOELECTRIC SENSORS

Long Range Photoelectric Sensors IP54

Type Through Beam Kits Through Beam Kit for
Note: Each kit includes emitter and receiver. Automatic Doors

Receiver Emitter

Receiver Emitter Receiver Emitter Receiver Emitter Battery operated 9V

Ideal for P41 – surface mount P40 – flush mount emitter-150 days minimum
automatic gates
Solar cell power supply on

request Note: Each kit includes 1 pair of projectors.
10M
Switching Distance 15M 35M 55M 15M
One Beam Selection
Available Receiver & Emitter Receiver & Emitter Receiver & Emitter Receiver & Emitter Infrared (875hm)

Emission Infrared (875nm) Infrared (875nm) Infrared (875nm) Relay: 8A @ 250VAC
70mA
Output 2 Relay SPDT Relay: 1A @ 24VDC 2 Relay
Output and activated thru beam indicator
Consumption 40mA 40mA 70mA Supply indicator
Present
Yellow LED Output Indicator Output indicator Output Indicator 5Hz
200mS
Green LED Supply Indicator Supply indicator Supply Indicator ≤ 300mS
-20° to 60°C
Sensitivity Adjustment – – – > 5000 Lux

Switching Frequency 50Hz - 60Hz 5Hz 1Hz Amplifiers IP54. Projectors IP65
Amplifiers ABS. Projectors Body – Lenses: methacrylate
Response Time – – 500mS
350 g
Start Up Delay ≤ 300mS ≤ 300mS ≤ 300mS 12VAC/DC BP10-120
Ambient -20° to 60°C -20° to 60°C -20° to 60°C 24VAC/DC BP10-240
Light Immunity 230VAC/DC BP10-220
> 5000 Lux > 5000 Lux > 5000 Lux(1) Wiring Diagram

Protection Degree IP54 IP54 IP54 8A
Housing Material PMMA Housing: glass-filled nylon – Filter: methacrylate

Weight (Approx) 160 g 315 g 340 g

12-24VAC/DC P63 P 41 P40 P44

9V alkaline battery P44

230VAC/DC – – – –

Wiring Diagram Wiring Diagram for Wiring Diagram for P44

EMITTER P63, P40 & P41 EMITTER RECEIVER
RECEIVER

12VAC/DC
or 24VAC/DC

Accessories for P41 8A

▼ C41080 105 Anti-Vandalism Projector Dimensions
▼ Box (grey)
500 LIMIT & PRESSURE SWITCHES & SENSORSCharacteristic Curve BP10
▼ 88
S410 ▼ 75 316

15 ▼

▼ 85
77
4.5 Metal Box ▼
42 wall mounting

(grey) 28 SI41

30 Metal Post (grey)
65
Accessories for P40 85 Solar Accessory for P44

C340 Box for wall SCP44
75 mounting
Battery operated 9V emitter-150
(grey) 530 days minimum. Solar cell power
supply on request.
75



S340

Metal Post (grey) ▼
60

DAT