DATA ACQUISITION & DISTRIBUTION
ACCESSORIES
Backplane for Power and
Communication
Code S401-L EASY SETUP SOFTWARE
Description Plug & Play set-up software for
OLED brightness display: 2,7" Interfaces: programmable devices
1 x RS485 Modbus Master +
1 x RS485 Modbus Slave
+ ++ Code Description
Z-PC-DINAL2-17.5 Head + 2 Slots
Code DATA RECORDER SOFTWARE S117P-1 Z-PC-DIN2-17.5 2 Slots
Z-PC-DIN8-17.5 8 Slots
Data acquisition Programming kit for head mount temp. Z-PC-DINAL2-35 Head + 1 Slots
visualisation & transmitters. Consists of: Serial Cables, USB to Z-PC-DIN1-35 1 Slot
recording software. RS232/TTL, Config. software Z-PC-DIN4-35 4 Slots
Cable Accessories
Code Description Terminal Type
RJ10/ DB9F
PM001420 RS232 serial cable (Z-TWS, Z-RTU, Z107, Z-LINK) RJ10/ DB25M
PM001430 Modem communication cable (Z-TWS) RJ10/ DB25M
PM001440 Modem and HMI communication cable (ZTWS, Z-RTU) RJ45/ RJ45
PM001450 Ethernet cable-right (Z-TWS - network device) RJ45/ RJ45
PM001460 Crossing Ethernet cable ( Z-TWS-PC) RJ10/ DB9M
PM001530 Modem serial cable (Z-TWS, Z-RTU) Jack/ DB9F
PM001601 Programming serial cable (Z-4AI-D, Z-4TC-D, Z8AI, Z-8TC, Z-4RTD2, Z-SG, Z203) DB9M/ Bolt Heads
PM002350 RS485 serial cable for Radio modem Tp-wire/ Bolt heads
PM002460 RS485 serial cable TP-WIRE (Z-TWS) RJ10/ RJ10
PM002470 Serial cable (Z-TWS, Z-RTU, Z107) RJ10/ Bolt heads
PM002480 RS485 Serial cable (Z-TWS) DB9M/ DB9F
PM002490 RS232 Serial cable - programming (Z-RTU, M-RTU, Radio Modem) DB9M/ DB9F
PM002500 RS232 modem for firmware updating (ZRTU, M-RTU, Radio Modem) DB9F/ Puntali
PM002510 Serial cable for Radio Modem DB9M/ DB9M
PM002520 Serial cable DB9F/ DB9F
PM002530 Serial cable
TRANSMITTERS
Signal Isolator Transmitter
Code S4X-DT-* DC Input Range DC Output Range
V2: 0-5V; V3: 1-5V;
*Add Supply Voltage: A = 85 - 265VAC/100 to 330 VDC or B = 20 - 60VDC V4: 0-10V; A1: 0-1mA; V2: 0-5V; V3: 1-5V; INSTRUMENTS & TELEMETRY
Multi-range Input / Output selectable by solder jumper wire on inside of unit. A3: 0-20mA; A4: 4 -20mA V4: 0-10V; A2: 0-10mA;
(AC/DC Workshop will set Input/Output configuration if requested on ordering) A3: 0-20mA; A4: 4 -20mA
Input - 3 Wire
Potentiometer Transmitter
Code S4X-DT-*
Supply Voltage: AC 85 – 265V/DC 100 – 330V Total Resistance - 100Ω - 10kΩ
RTD (PT100) Transmitter (Isolator)
Code S4X-RR-P*-A4-* DC Output Multi Range (Selectable by Dip Switch)
* Add °C to code: F (0 - 100°C), D (-50 - 200°C), G (0 - 200°C) V2: 0-5V; V3: 1-5V; V4: 0-10V;
* Add Supply Voltage: A = 85 - 265VAC/100 to 330 VDC or B = 20 - 60VDC A1: 0-1mA; A2: 0-10mA; A3: 0-20mA; A4: 4 -20mA
Speed (Frequency Transmitter) Specifications
Code Description Code Description Accuracy: ± 0.1% RO.
Isolation: Input/Output/Power
S4X-RT-B-2-M-A 0-100Hz Input S4X-RT-F-2-M-A 0-2Hz Input Insulation Resistance: ≥ 100MV, DC 500V
Impulse Withstand Test: IEC 1000-4-5, class 4
S4X-RT-E-2-M-A 0-1KHz Input S4X-RT-H-2-M-A 0-10KHz Input
Supply Volts: 85-265VAC Output Programmable: 4-20mA, 0-10V
DPM 258
GENSET CONTROLLERS
All controllers are DSE702 DSE331 DSE4520 DSE6120 DSE7320
suitable for 12/24VDC
systems. Manual Start / Stop ATS AMF AMF AMF
Code N 4 4 4 4
Application 1 4 4 6 8
Config DC Output N
Config Input Dedicated N Can be Configured Can be Configured Can be Configured
Oil Pressure Dedicated Y Can be Configured Can be Configured Can be Configured
Coolant Temp 4 Can be Configured Can be Configured Can be Configured
Remote Start Y N
Config Relay Output N N N N 2
Fuel & Crank Output Y N Y Y Y
Pre Heat relay Output Y N N N N
Analogue Input N N 3 4 4
E-stop Input Y N Y Y Y
Current Input N N Y Y Y
MPU Pick-Up N Y N Y Y
CANbus N N Y Y Y
USB Port N N Y Y Y
RS232 Port N N N N Y
RS485 Port N Y N N Y
Event Logging N Full 50 Events 100 Events 250 Events
PC Config N Y Y Y
Front Config N 180 x 116 x 42 Full Partial Partial
Dimensions (mm) 84 x 72 x 35 154 x 98 140 x 113 x 43 216 x 158 x 42 240 x 181 x 42
Panel Cut Out (mm) 80 x 68 8- 35VDC 118 x 92 182 x 137 220 x 160
Supply 8 - 35VDC 8 - 35VDC 8 - 35VDC 8 - 35VDC
DSE890 Accessories
Code Description
DSE890 Gateway for remote monitoring & control connects to DSE data server by Ethernet, GPRS, RS232 or
RS485. Includes GPS functionality. Suitable for use with controllers with USB Port.
DSE-GSMANT GSM Antenna
DSE-GPSANT GPS Antenna
Automatic Manual Key Start
Transfer Switch Controller
Model EAOM-36 EAOM-7 EAOM-71 ATS-10 EAOM-3
Controls
INSTRUMENTS & TELEMETRY Automatic engine Start/Stop Y Y Y Controls Fuel and stop solenoid
Automatic Shutdown on fault Generator remote start Starter motor
condition Y Y Y Load transfer to mains Manual generator start/ stop
Alternator voltage and fre- Mains and generator Preheat (Glow Plug)
quency measurement Frequency Generator Voltage/ Generator Voltage/ contactor Monitors
Measurement Power Measurement Power Measurement Monitors Engine running time
Load current measurement 3 Phase mains voltage Error Indication
Remote Start/Stop input N 3 Phase 3 x 1 Phase Alternator voltage Fail Monitoring
3 resistive sender units Y Y Y Program parameters Low oil pressure
User configurable inputs N N Y High temperature
User configurable outputs 2 3 3 Over speed failure
Speed sensing off Alternator 1 2 2 Charging fail
Speed sensing off magnetic Y Y Y
Pickup 72 x 72
RS-232 Serial Comms N YY
Remote use from PC
Standard Modem Comms Y Y Y 72 x 72
Display Y Y Y
N Y Y
Size (mm) LED LED LED
72 x 72 96 x 96 96 x 96
259
DPM
ANTI-HARMONIC PFC
Anti-Harmonic PFC Plug-In Systems
Code Code with kVAr at Steps Step values @400V Dimensions
Comms 400V 25kVAr 50VAr H x WxD
VMPH-150 VMPHC-150 150 4 2 2 1600 x 800 x 600
VMPH-175 VMPHC-175 175 4 1 3 1600 x 800 x 600
VMPH-200 VMPHC-200 200 5 2 3 1850 x 800 x 600
VMPH-225 VMPHC-225 225 5 1 4 1850 x 800 x 600
VMPH-250 VMPHC-250 250 6 2 4 2050 x 800 x 600
VMPH-300 VMPHC-300 300 7 2 5 1600 x 1600 x 600
VMPH-350 VMPHC-350 350 8 2 6 1600 x 1600 x 600
VMPH-400 VMPHC-400 400 9 2 7 1600 x 1600 x 600
VMPH-450 VMPHC-450 450 10 2 8 1600 x 2400 x 600
VMPH-500 VMPHC-500 500 11 2 9 1600 x 2400 x 600
VMPH-600 VMPHC-600 600 12 0 12 1600 x 2400 x 600
Connect ready Automatic Power Factor Correction Systems where harmful harmonics exist as caused by
UPS, VSDs and other similar devices. It is always recommended that a detailed site analysis be undertaken
before ordering.
• Robust design for systems subjected to VTHD <7% and ITHD <20%. VTHD<14% on application.
• Top, bottom and side cable entry.
• Plug-in full busbar system.
• Thermostatically controlled forced cooling
• Door interlocked isolator with surge protection and control fuse protection.
• Data acquisition option with GSM comms and PC software. Sim card required.
• Each plug-in step includes:
- Heavy duty 440V harmonic filtration rated capacitors with discharge resistors
- Fusegear and capacitor switching rated contactor T2
- Anti-Harmonic reactor
ENERGY SAVING INSTALLATIONS - COMMERCIAL & DOMESTIC
Passive Power Factor Correction
Power Factor Correction (PFC) is a technique of counteracting the undesirable
effects of electric loads that create a power factor less than one. This range of
passive (PFC) units can save 10%-20% of energy consumption.
Code Description Dimensions
ES100 Single Phase (2000kWh pm) 125 x 85 x 60
ES100 ES300 Three-Phase (6200kWh pm) 190 x 140 x 70D
ES300
ES3001 Three-Phase (10 000kWh pm) 240 x 190 x 90D
ES3002 Three-Phase (15 000kWh pm) 240 x 190 x 90D
Features Technical Info The three-phase energy saver can be
wired either at the DB or the incoming
• Prolongs life of appliances • Single-Phase voltage: 220-240VAC 50Hz Eskom box.
• Stabilise electrical current • Three-Phase voltage: 380-420VAC Note: As long as the black is connected
• Available in single and three-phase • Operating temperature: 60˚C (max.) to neutral, it does not matter which of
• Suitable for home, shops, offices, the other wires connect to which phase.
CAPACITORS & PFCs
restaurants, etc.
Combination Geyser / Power Factor Protection & Surge Protection Technical Info
Combination units consist of both geyser controller and passive power factor • Single-Phase voltage: 220-240VAC 50Hz
(energy saving). These are parallel connection types, for single and three • Three-Phase voltage: 380-420VAC
phase units, some available fitted with surge protection. • Surge Protection: 65kA
Code Description Dimensions
ES100-GC 170 x 200 x 85mm
Single phase power + Geyser controller
ES100-GC-SS Single phase power + Geyser + Surge protection 170 x 200 x 85mm
ES100-2GC-SS Single phase power + 2 x Geyser + Surge protection 170 x 200 x 85mm Red (or Brown) White (or Brown) wire to
ES300-GC Wire to Red Phase Secondary side of Geyser
ES300-GC-SS C/B (or Isolator)
ES300-2GC-SS Three phase power + Geyser controller 210 x 215 x 100mm White (or green/ Yellow)
Wire to Phase Red Wire to Geyser
Three phase power + Geyser + Surge protection (3ph+N) 210 x 215 x 100mm Blue wire to Ditto for other controllers
Three phase power + 2 x Geyser + Surge protection (3ph+N) 210 x 215 x 100mm Blue phase
Black Wire
to Neutral
265 T
THERMOSTATS
Code Contact Rating Control
Clima – Series 6-30˚C Surface mount
CLIMA ML 16A Heating only
MLI ML CLIMA MLI 10A Heating only + on/off switch
MLW
CLIMA MLW 10A Heating – Off – Cooling
CLIMA FC 10A Heating – Off – Cooling, Speed 1/Speed 2
CLIMA FC
Rio – Series 6-30˚C Surface mount
VN650800 15A Heating only
Heating/Cooling + on/off switch
VN652400 10A Heating/Cooling + on/off switch + on lamp
VN653200 10A
Room Thermostats 10-30°C
BEL-B1 BEL4118-A2 A7700 A7700 16A Heating only 10 - 30˚C with on/off 20A isolator mounting into stan-
BEL-B2 BEL4118-B1 BEL4118-E1 dard 4 x 2 box. Max switching 3600W
16A Heating only 10-30°C with on/off switch mounting into
BEL4118-A2 75 x 75mm box
16A
Heating only with on/off switch mounting into 75 x 75mm box c/w
BEL4118-B1 remote sensor with 3m cable, adj between 10 - 50˚C.
BEL4118-E1 16A LCD Electronic Thermostat. heating only 10-30˚C with 7 day timer
programmable. 6 times, 6 temperature settings per day. Remote
sensor with 3m cable
BEL-B1 – 75 x 75 x 32(D)mm Flush Mount Wall Box
BEL-B2 – 86 x 86 x 32(D)mm Surface Mount Box
Thermostats for Air Conditioning Systems (Surface Mount)
Temperature Control 10-30˚C
BEL-3538/03A 5A 3 Speed Fan Switch with 10-30°C Temp. Control and on/off switch
BEL-3538/03LA 5A As BEL-3538/03A with Digital Temp. Display
BEL-3538/03A BEL-3538/03LA
Digital Room Thermostats
NEO-ML 7A Heating only for surface mounting. Temperature regulation 5 - 35˚C
DECO-TERMO 8A Heating and cooling, control with two programmable temperature
levels, mounts into 75 x 75mm box.
Temperature range 0-40˚C TEMPERATURE CONTROLS
DECO-TERMO NEO-ML Thermostats - c/w Timing Functions
NEO ERA
ERA 5A Heating and cooling with comfort and saving settings. Daily timing.
DECO CRONO NEO 5A Temperature range 10 - 40˚C.
DECO-CRONO 8A Heating and cooling with 2 temperature settings and anti-ice setting.
Weekly timing with 8 programs . Surface mounting. Temperature
range 0 - 50˚C
Heating and cooling with 2 temperature settings and anti-ice setting.
Weekly timing with 8 programs. Mounts into 75 x 75mm box.
Temperature range 0 - 40˚C.
TC 266
PID TEMPERATURE CONTROLLERS
Universal 4 Digit Temperature Controller – Dual Indication (full PID controller)
Control Relay & Alarm Relay TZN4S-14R TZ4ST-14R TZN4M-14R TZ4L-14R TZ4H-14R TZ4W-14R
4-20mA output & Alarm Relay TZN4S-14C TZ4ST-14C TZN4M-14C TZ4L-14C
Control Relay + 2 Alarm Relays TZN4ST-24R TZN4M-24R – TZ4H-14C TZ4W-14C
Size (H x W) - 48 x 48mm
48 x 48mm 72 x 72mm / 96 x 96mm – TZ4W-24R
96 x 48mm 48 x 96mm
Features • S V2 input for oven door interlock Specifications
• Indicating accuracy of ±0.3% ( F - S)
• 2 x 7 digit LED displays: • D ual PID function selectable fast response • M ulti-volt Supply: 100 to 240VAC
PV (Process Value) RED • C onsumption: 5VA
SV1 (Set Point Value) GREEN PID action (PIDF) or slow response PID action (PIDS) • C ontrol Relay output: C/O 3A @ 250VAC
• Control: ON/OFF, P, PI, PD, PIDF, PIDS control • S ampling time: 250ms
• M easure range: multi-range and pre-scalable
• Input types: T C (J, K, R, S, T,...)
RTD (PT100...)
0-10V, 1-5V, 4-20mA
Connection Diagram for TZN4S Connection Diagram for TZN4M Connection Diagram for TZ4H
Control
O/P ‘C’
TEMPERATURE INDICATORS
Indicator Indicator 5 Sensor Input Indicator Indicator Indicator
TEMPERATURE CONTROLS Code: PT100 T3NI-400P T4YI-400P T4WM-400P MTR10-599P SG-781*P SG-681*P
Code: J – T4YI-500J T4WM-500J MTR10-999J SG-781*J SG-681*J
Code: K – T4YI-1200K T4WM-1200K MTR10-999K SG-781*K SG-681*K
Size 36 x 72mm 48 x 96mm 72 x 72mm 96 x 96mm
Supply Volts 24 x 48mm 100-240VAC 110-240VAC 34 x 76mm
12-24VDC 230VAC 110-230VAC
Temperature Range – – *Add Temp Range to code:
– – 100, 200, 400°C
267 TC
DIGITAL TEMPERATURE CONTROLLERS
Accuracy ±0.25%
Read Rate 3/sec
Code ESM4410-*-230 ESM4420-** ESM-4430-** ESM-7730-** ESM4435-**
Voltage 230VAC 230VAC, 115VAC, 24VAC/DC 100-240VAC / 24VAC/DC 100-240VAC / 24VAC/DC 100-240VAC / 24VAC/DC
On/Off On/Off, P, PI, PD, PID On/Off, P, PI, PD, PID
Control Method On/Off, P, PI, PD, PID On/Off, P, PI, PD, PID Auto / Manual Auto / Manual
PID Tuning ― 4 digit 10mm (red) 4 digit 10mm (red)
Process Display 3 digit 10mm (red) Auto / Manual Auto / Manual 4 digit 8mm (Green) 4 digit 8mm (Green)
Set Value Display Display during set-up
Sensor Input * Select when ordering 4 digit 10mm (red) 4 digit 10mm (red) J, K, R, S, T,B,E,N, PT100 J, K, R, S, T,B,E,N, PT100
Process Inputs N/A 0-50mV/5V/10V, 0/4-20mA
N/A 4 digit 8mm (Green) 4 digit 8mm (Green) 0-50mV/5V/10V, 0/4-20mA
Process Supply ― 0-50mV/5V/10V, 0/4-20mA
Heating/Cooling √ J, K, R, S, T, PT100 J, K, R, S, T,B,E,N, PT100 √ √
Programmable Alarms ― √ √
N/O Relay 7A@250VAC N/A N/A N/O Relay 5A@250VAC
Output 1 ― N/O Relay 5A@250VAC N/O Relay 5A@250VAC
― ― 0-50mV/5V/10V, 0/4-20mA N/O Relay 5A@250VAC 0/4-20mA / 0/2-10V
Output 2 48x48x116mm SSR (20mA@12VDC) 48x48x116mm
Output 3 √√
3 readings/sec 72x72x87.5mm 3 readings/sec
Size √√ 3 readings/sec
Read Rate
N/O Relay 5A@250VAC N/O Relay 5A@250VAC
N/O Relay 5A@250VAC N/O Relay 5A@250VAC
SSR (20mA@12VDC) SSR (20mA@12VDC)
48x48x116mm 48x48x116mm
3 readings/sec 3 readings/sec
* Add to code J = J-Type, K = K-Type, P = PT100, N = NTC
** Add to code 230 (230VAC), 240 (100-240VAC), 115 (115VAC), 24 (24VAC/DC)
Features
• User friendly installation and operation. • Adjustable hysteresis for greater flexibility
• Universal Input TC, RTD, mVDC, VDC,mADC (excl ESM4410) • Text based Function menu for ease of set-up
• Automatic or manual PID tuning for greater control • Dual Display of process temperature and set value (excludes ESM4410)
• Adjustable PID cycle time for greater control • Adjustable On and Off delay on alarms
SCR HEATER ELEMENT REGULATORS
Voltage Control for Heaters Single Phase (230V)
Code Current KW Ultra fast Code Current KW Ultra fast
Fuse Fuse
SG-027 27A 6 30A SG-100 100A 22 100A
SG-057 57A 12.5 60A SG-132 132A 29.3 160A
SG-162 162A 36 160A
Three Phase (400V)
Code Load KW Ultra fast Code Load KW Ultra fast
Current Fuse Current Fuse
16.5 SG-3100 100A 66 100A
SG-325 25A 33 25A SG-3130 130A 86 160A TEMPERATURE CONTROLS
SG-350 50A 49 50A SG-3160 160A 105 160A
SG-375 75A
75A
Benefits Specifications Output Voltage: 0-100%
Input Signal: 4-20mA, 0-20mA, 1-5VDC. 0-5VDC Constant- Voltage Characteristics: Output accuracy 1%
• Small size, saving space Control System: Phase control Ambient Temperature: -10/50°C Humidity 90% RH below
• H igh accuracy and fast response Insulation Resistance: 500VDC (10g ohms) VR1: Min V output Ads.
• Eliminates contactor noise VR2: Max V output Ads.
• Extends heater life Connection Diagram
• High efficiency, no maintenance
• M aintains stable process
temperature
TC 268
TEMPERATURE CONTROLLERS
ON/OFF Analogue Setting Analog Setting Thumbwheel Setting
Control Analogue Setting & Deviation & Full Scale Display & Digital Display
Display
Size 96 x 48 – – – – – KE-861*
–
Size 72 x 72 KE-714* KE-724* – KE-742* KE-771* –
Size 96 x 96 KE-612* KE-622* KE-632* KE-642* KE-671* KE-861/A*
–
72 xW7i2th/ 9a6laxrm96 – – – – KE-771/A*/KE-671/A*
Range & Probe Digital
*Add temperature 100, 200, 400 or 600°C and Probe type PT100., J or K e.g. KE-724 200K
Higher Range ‘K’ – – 800 & 1200°C –
Technical Specifications Connection Diagram
Supply: 110/220VAC Output: Relay 1C/O
Input: Thermocouple 5A@250V
K, J and PT100 Hysteresis: 2,5% full scale
Accuracy: 1% of full scale Alarm: 10% of full scale
Control: On/Off action
Digital 1 Set Point Digital 2 Set Point Thumbwheel 1 Set Point Analogue 1 Set Point
ON/OFF
Control
Size 72 x 72mm 72 x 72mm 48 x 48mm 48 x 48mm 34 x 76mm
Probe PT100 TR-48*P *100, 200, 400°C MTR11-150PTC*
Probe J & K VM6251 -99° to 999°C VM6269 -99° to 999°C TP-48*P *100, 200, 400°C TR-48*J *100, 200, 400°C
TR-48*K *100, 200, 400°C –
VM6392 -99° to 999°C VM6400 -99° to 999°C TP-48*J *200, 400°C
Reversed 8 pin P3G-08 –
Technical Specifications TP-48*K *200, 400°C
• Supply: 230VAC
Supply: 24 or 230VAC • D irect/Reverse PWM & All supplied complete with * C/W Probe
Input: Thermocouple K, J Neutral zone operation Range: 50-150°C
& PT100 Y-50 mounting bracket Spare Probe: PTC150
Accuracy: 1% of full scale Specifications:
Output: Relay C/O 8A@250V Connection Diagram Supply voltage
110-240VAC
TEMPERATURE CONTROLS • Min/Max Alarms Hysteresis 2,5% full scale
• D ifferential or Hysteresis Relay output: 1 C/O @ 2A
p rogrammable 250VAC
Panel-mount or 8 pin
plug-in.
When using 2-wire PT100 Probe, short circuit terminals 4 and 5 Connection Diagram
Transparent cover for 72 x 72 Adaptor for 72 x 72 to 96 x 96
VJ4482 VJ4458
Supply
Volts
269 IP54 TC
For blind temperature controllers, see pages 6 & 24.
TEMPERATURE PROBES
Thermocouples
NOTE: Wire Colours - J: Red & Blue, K: Red & Green, PT100: 2 x White, 1 x Red
PVC Cable
Probe size 100mm x 5.0 Ø
Cable: 1.5m
Steel Cable
Probe size 100mm x 5.0 Ø Thread size 1/4” or 1/2” Steel Braided Cable PVC Coated Probe:
Cable: 1.5m Cable: 1.5m 1/2” Thread
150mm x 5.0 Ø
Probe Thermo- Temp Cable Screw Temp Code Description Com
Type couple Range Type Type Range Head Large pression
Type Code Type Head Clamp
Code Code
PT100 TC-P 100D 100°C PVC TC-P/S* 400°C TC-P2 CABLE 200°C PVC coated Grey KSE-P KEN-P 1/2” Brass
TC-P4 CABLE 400°C Steel braided CC-02B
Std 1/4” thread 200°C PVC KSE-J KEN-J
PT100 TC-P 200D* 400°C Steel KSE-K KEN-K 1/4” Brass
PT100 TC-P STEEL CC-04B
400°C Steel TC-J/S* 400°C TC-J CABLE 400°C Steel braided
Std ¼” thread 400°C Steel TC-K/S* 400°C TC-K CABLE 400°C Steel braided 1/2” S/Steel
Type J TC-J* CC-02S
Type K TC-K* *Specify 1/4” or 1/2”
1/4” S/Steel
*Specify 1/4” or 1/2” CC-04S
Head Mount Temperature Transmitter - Programmable & Loop Powered Thermocouple Connectors
Code T121
Description Programmable using Programming Kit S117P-1 (see page 258)
Input: PT100, Ni100, PT500, PT1000, J, K, R, S, T, B, E, N thermocouples
Power Supply: 7 - 30 VDC. Current Output: 4/20 or 20/4mA (2 wire) Female Male
Resolution: 2μA (>13bit). Response Time: >1s
Over range fault output: 102.5 - 105% full scale FPL-PT100 MPL-PT100
Connection by spring terminals: (wire size 0.2 - 0.25mm² ) FPL-J MPL-J
Size: 20mm x 43.7mmØ FPL-K MPL-K
Temperature Transmitter (2 wire) - Fits into Head Type KEN-P/J/K
Code Temperature Range Specifications
Output Signal: 4 - 20mA DC
TRT-PT100* 50, 100,150, 200, 400°C Power Supply: 10 - 36VDC
Accuracy: ±0.15% F.S. (PT100)
TRT-J* 100,150, 200, 400, 600°C ±0.5% F.S. (J & K)v
Installation TRT-K* 100,150, 200, 400, 600, 1000, 1200°C
example
*Add Temperature range to code
TEMPERATURE SWITCHES
Electronic Temperature Switch Mechanical Temperature High Performance Temperature Switch TEMPERATURE CONTROLS
- with fixed Switching Point IP66 - with Power relay, with fixed Switching Point IP67
- with programmable LED Display IP65
• 12 - 24VDC, 48VAC • 24VDC
• 12 - 30VDC • 4A Switch rating • 30A Switch rating
• 100mA
• M12 4-pin Plug
Probe Size: Probe Size: Cable:
Ø6 x 0.75mm (up to 40 Bar) Ø10mm (up to 100 Bar) 1.5m open leads
Length: 25mm Length: 28mm 1/2" thread
SL6410* S6410*
Code Output Temp Code Output Temp Code Output Temp
Range Range Range
TC5400-* 2 x PNP -50 to 125°C SL6410-*-** NO/NC + 40 to 200°C S6300-* NO - 20 to 120°C
TC5410-* 1 x PNP & 1 x 4-20mA -50 to 200°C S6410-*-** NO/NC + 40 to 200°C - - -
*Specify 1/4" or 1/2" thread **Add Temperature: 040, 060, 080, 100, 120, *Add Temperature: 040, 050, 060, 070, 080,
140, 160,180, 200°C 090, 100, 110°C
e.g. SL6410-1/4-040 e.g. S6300-040
*Specify 1/4" or 1/2" thread
TC 270
TEMPERATURE CONTROLLERS IP64
Size: 76 x 36mm
Cutout: 71 x 29mm
Display: 3 Digit + Sign
Code KLT11BB-J (J Probe) KLT11D KLT11D2 KLT12D KLT22D KLT32
KLT11BB-K (K Probe)
Range -50 to 150°C
J = 0 to 700°C
Supply K = 0 to 999°C 230VAC, 110VAC, 24VAC/DC or 12VAC/DC to be specified
Probe (excluded)
J or K Probe PTC or NTC PTC or NTC PTC20±2°C / PTC05±0.5°C
Output relay Program Selectable Program Selectable Program Selectable
N/O 16A Control, C/O 5A
Function 1 Relay C/O 16A N/O 20A 16A N/O Control Defrost, N/O 8A Fan
Alarm C/O 16A N/ O 8A C/O Defrost
Communication Control Control for compressor,
Card Output (KL-KEY) 2 Alarm set points Control C ontrol Control & fan & defrost
Connection Diagram Defrost –
Yes
– – – –
Yes Yes Yes Yes
KLT11D KLT12D 16A
KLT11D2 KLT22D 16A 8A
Specifications • Cooling or heating • Cooling or heating • 1 or 2 Probe selectable • 1 or 2 Probe selectable
• Inside alarm buzzer • High & low value set point • Designed for refrigeration • D esigned for refrigeration
• Accuracy 1% • A ble to program 23 • A ble to program 52
different parameters, i.e. different parameters, i.e.
hysteresis, defrost time hysteresis, defrost time
Temperature Indicators Accessories (Probes c/w 1.5m cable)
Code TKTZ DT-101S Code Description
Range -50 to +99°C
TEMPERATURE CONTROLS Supply 230VAC or 115VAC -40 to +70°C PTC20 PVC Cable. Accuracy ± 2°. Range -50°C / 105°C
Probe PTC20 (included) Battery included PTC05 PVC Cable. Accuracy ± 0.5°. Range -50°C / 105°C
Size 62(W)x29mm(H) 1.1m cable (included) NTC20 PVC Cable. Accuracy ± 1°. Range -50°C / 105°C
48(W)x28mm(H)
KLRS485 KLGATEWAY
Communication Accessories - for KLT Range
Code Description
KLRS485 Isolated RS485 Communication Module for KLT Range Controllers
KLRTRL Interface Cable between Controller & KLRS485
KLUSB485 RS485 - USB Interface between PC and KLT Devices
KLGATEWAY RS485 - Ethernet Interface between KLT Controller Installation and
KLNetCenter through Lan or Internet
KLUSB485
271 TC
HUMIDITY & TEMPERATURE CONTROLS
Humidity Sensors Combined Humidity & Temperature Sensors
IP30 1.5m cable length 1.5m cable length
Code VN8736 KLSH03 TH-102W TH-101D TH-103S
Supply Voltage
Range 9-30VDC / 12-24VAC 5VDC 12/24VDC 12/24VDC 12/24VDC
20-90% RH 10-90% RH 0-100°C / 0-100%RH 0-100°C / 0-100%RH 0-100°C / 0-100%RH
Output 4-20mA or 0.1-1V 1 to 3VDC 4-20mA (2-wire) 4-20mA (2-wire) 4-20mA (2-wire)
HUMIDITY CONTROLLERS TEMPERATURE & HUMIDITY CONTROLLER
IP65 Features
Code KLTH43 • R ed display for
temperature and green
Code DPM-RH-* KLH11RH Size 134 x 105mm display for humidity
Cutout Size 130.5 x 100.5mm • T emperature control can
76 x 36 x 60D mm Supply 230VAC be ON/OFF, n eutral zone
Size 72 x 72 mm 110VAC or 230VAC Temp. Range -50°C to 150°C (0.5%) or refrigeration
Supply 110VAC or 230VAC 0-1V, 1-3V KLSH03, Hum. Range 0-100% RH (5%) • Second temperature
Input* 4-20mA (VN8736) / 1-3V Temp 2 x PTC05 ±0.5% or PTC20 ±2% probe can be used for
0-100% RH Probes defrosting control
Range 0-100% RH • Humidity control can be
Differential or Hysteresis (excluded) Humidity 1 x (0-1V) / (0-3V) 4-20mA probe ON/OFF or neutral zone.
Settings Hysteresis Adj. Relay C/O 8A 4 SPDT Relays 8A @ 250VAC • H umidity probe (0-1V) /
Output Relay C/O 8A Outputs (0-3V) / (4-20mA) select
able by programme
Display Red for temperature; Green for humidity • Resolution:
Temp: 0.1°C
Humidity: 1%
Indicators Indoor In/Outdoor Wireless Weather Centre
Thermometer Thermometer
Code CTH-608 CTH-609 WS1170
Wall or Table mount (back stand built-in) • Display: in °C or °F
• Temperature Ranges:
Memory store and recall of max/min temp. and humidity
Indoor:
Clock: 12/24hr Format, Alarm, Calendar Function 0°C to 60°C (built in)
Outdoor:
CTH-608 Battery: 1 x AAA size (included) -40°C to 65°C (wireless x1)
CTH-609 • H umidity Range:
LCD Size 80 x 70mm 1%RH-99%RH
• A ccuracy: ±1°C
Temperature Display in "C" or "F" selectable Battery: 3 x 1.5V AA (excluded)
Sensor: 2 x 1.5V AAA (excluded)
WS1170 Range: -10ºC to 50ºC ±1ºC
Indoor: -14ºF to 122ºF±1.8ºF
Range: -50ºC to 70ºC ±1ºC Outdoor: -50ºC to 70ºC ±1ºC TEMPERATURE CONTROLS
-58ºF to 158ºF±1.8ºF
- -58ºF to 158ºF±1.8ºF
Humidity: 10% to 99%RH±1% Frost Warning: -1 to 4ºC
Humidity: 20% to 99%RH±1%
Temperature & Humidity Temperature Only Indicator Glass Temperature Thermometer
Indicator Indicator
TH-920 TH-922 CS-120
Size mm: 360H x 395W x 100D • 0-100°C Temp • 0-120°C/20-180°F
• 0-100% Humidity • 1/2” BSP thread
• Length: 150mm
• Supply 85-265VAC
• Sensor TH-101/2/3 • Size mm: 200H x 395W x 100D
or VN8736 (see above) • 0-100°C Temp
• Input: 4-20mA • Supply 85-265VAC
• Digit size mm: 100H x 60W • Input: TC-P 100D
TC 272
DIGITAL DEFROSTING & TEMPERATURE CONTROLS
Temperature Controllers for Walk-in Freezers and Cooling Displays
Size: 71 x 28 x 71mm
Cut Out: 71 x 29mm
Display: 3 Digit/Sign
Code TC-900RI-CL TC-900RI-P TC-920RI TC-940RI-P
Range -50 to +75˚C/ -58 to 167 F
Supply -50 to +75˚C/ -58 to 167 F -50 to +75˚C/ -58 to 167 F -50 to +75˚C/ -58 to 167 F
Probe 115 or 230VAC ±10% 90-264VAC 115 or 230VAC ±10% 115 or 230VAC ±10%
2 x SB19 2 x SB19 3 x SB19 2 x SB19
Relay Output NTC Sensor (Inc.) NTC Sensor (Inc.) NTC Sensor (2 Inc.) NTC Sensor (Inc.)
N/O 5A Refr N/O 16A Comp N/O 5A Refr
Coms N/O 5A Fans N/O 5A Fans N/O 5A Fans N/O 16A Comp 3A N/O Alrm
Function N/O 5A Defrost N/O 8A Defrost N/O 3A Defrost N/O 5A Defrost
Connection diagram Yes No N/O 5A Fans
Control/ Ref/ Defrost No Control/ Ref/ Defrost Yes
Control/ Ref/ Defrost
Control/ Ref/ Defrost
Remote management
software R/ deaayl t&imienteclroncakl,buapttetory8 defrost
Code: SITRAD
Refrigeration Frozen
Size: 71 x 28 x 71mm Display: 2
Cut Out: 71 x 28mm Digit/Sign
Display: 3 Digit/Sign
Code MT-512RI MT-512RI-LOG TC-900RG2
Range -50 to +75˚C/ -58 to 167 F
Supply 0 to 50˚C/ 32 to 122˚F -50 to +75˚C/ -58 to 167 F
Probe 115 or 230VAC ±10% 115 or 230VAC ±10% 115 or 230VAC ±10%
1 x SB19 2 x SB19
Relay Output 1 x SB19
NTC Sensor (Inc) NTC Sensor (Inc)
Coms NTC Sensor (Inc) N/O 16(8)A/ 250VAC 1HP N/O 16(8)A/ 250VAC 1HP
Function N/O 16(8)A/ 250VAC 1HP
Connection diagram N/C 8A/ 250VAC N/C 8A/ 250VAC
N/C 8A/ 250VAC Yes No
Remote manage- Yes
ment software Refrigerate Control/ Comp/ Defrost/ FANS
Code: SITRAD Refrigerate/Display coolers
Temperature & Humidity
Size: 71 x 28 x 71mm With a timer for cooling & defrost times
Cut Out: 71 x 28mm Temperature Controls
Display: 3 Digit/Sign
TEMPERATURE CONTROLS Code MT-516RVTI MT-518RI MT-530SUPER
Range -50 to 105˚C
Supply -50 to 105˚C -50 to 105˚C
Probe 115 or 230VAC ±10% 115 or 230VAC ±10% 115 or 230VAC ±10%
1 x SB56 NTC Temperature and
Relay Output 1 x SB19 1 x SB19
NTC Sensor (Inc) NTC Sensor (Inc) Humidity Sensor (Inc)
Coms N/O 8A/ 250VAC 1HP N/O 8A/ 250VAC 1HP 3 x N/O 5A @ 250VAC
Function N/O 8A/ 250VAC N/O 8A/ 250VAC
Connection diagram Temp/Humidity/Aux
Yes No Yes
Remote manage- Temperature Controller with over/under voltage protection Temperature Controller/Cooling or Heating
ment software Temperature/ Humidity Controller
Code: SITRAD For milk cooling Includes For air conditioning
For data centres & genl. aircon
273 Cyclic
Timer
0-999min
TC
POWER MONITORS TIMERS TEMPERATURE DISPLAY
Instrument for Scheduler with real- The big therm is a
measuring and time clock that digital thermometer.
monitoring the allows configuring The dimensions and
major parameters up to four events design of this
regarding energy for each weekday, instrument allow the
quality on three- through the defini- temperature for
phase electrical tion of start and end long-distance
installations times for each one. visualization.
Code PHASE LOG PLUS PROGS-1 TIC-17G
Supply
Control Range 85 to 265VAC (50/60Hz) 85 to 265VAC (50/60Hz) 110 or 220VAC (50/60Hz)
Current 90-500VAC 24hr, 365 days -55 - 90˚C
Dimensons
Operation Temp 5A/ 250VAC 1/8hp 10A (resistive load) NTC with cable 1,5m
Communication 71 x 28 x 71mm 70 x 28 x 60mm 90 x 44 x 27mm
Application 0-60˚C 0 - 50˚C
0-50˚C No No
Features yes, RS-485
Electrical panels Ovens, injection machine, defrost control Refrigerating equipment greenhouse, ovens,
Other multi-phase equipment climatized rooms.
Over/ Under voltage (Adjustable) Remote Management Software
Phase Failure & Phase Sequence
Code SITRAD-*
Data Logger Per Phase
More than just automation, sitrad innovates in the management of cooling, heating, air conditioning, and solar heating
systems by means of its most distinguishing feature: connectivity. The user can continuously evaluate, configure and
store data on temperature, humidity and pressure, among others
• *Local: must be installed in the computer to which the instruments are connected via interface
• *Remote: must be installed in the computer that will remotely manage the installation, via Internet
• *Mobile: manages facilities via cell phone, communicating with the local module
With mobile, the user has another option for remote management. Without using a computer, it provides even easier
remote installation management. It is the connectivity allowing to take over the control, anytime, anywhere
DIGITAL DEFROSTING & TEMPERATURE CONTROLS
Differential Temperature Controllers for Pumped Solar Heating Systems
Code ANASOL MICROSOL RI *V6 MICROSOL II *PLUS
Features
Economy range of differential Differential thermostat for automation of Differential temperature controller for
Supply temperature controller used to control pumped solar heating systems. automation of pumped solar heating
the pump of solar water heating With Anti-Freeze and Overheating systems.With Anti-Freeze, Overheating
applications. With Anti-Freeze function. functions. and solar back-up functions.
Supplied with 2 colour coded sensors. Supplied with 2 colour coded sensors. Supplied with 3 colour coded sensors.
115-250VAC 115-250VAC or 115-250VAC or
* Add "L" for 12-24VAC/DC * Add "L" for 12-24VAC/DC
Control Range -50 to 105°C
Load Current 16A@ 250VAC 1HP -50 to 105°C -50 to 105°C
Operating Temp 16A@ 250VAC 1HP 16A@ 250VAC 1HP
0° to 50°C
No. of Sensors IP's 2 Colour Coded 0° to 50°C 0° to 50°C
Dimension 100 x 72.8 x 36.8mm 3 Colour Coded 3 Colour Coded
Connection Diagram 71 x 28 x 71mm 71 x 28 x 71mm
115V
230V
Sensor 1
Black Cable
Sensor 2
Grey Cable
Sensor 3
Black Cable
COMMON
NO
NC
Serial Communication
RS-485
Sensor 1
Black Cable
Sensor 2
Grey Cable
Sensor 3
COMMON
PUMP
ACDC1
ACDC2
TEMPERATURE CONTROLS
115V 230V Load 230V 115V
Power
Sensor S1 - Black Silicone Pump Power Load Supply
Panels or Solar Collector Supply Supply
Load Supply To the terminal of distribution box
Sensor S2 - Grey PVC
Reservoir/Pool Power Supply
5-6 / 115V
5-7 / 230V
TC 274
RADIO REMOTE CRANE & MACHINE CONTROL IP65
8 Button Hand Held Controllers 10 Button Hand Held Controllers
With Display
Code 946091-400 949190-400 946093-400 949192-400 947704-400
Functions 10 x 2 Stage Buttons
8 x 2 Stage Buttons 8 x 2 Stage Buttons 10 x 2 Stage Buttons 10 x 2 Stage Buttons Quick Stop Switch
Markings Quick Stop Switch
Display Quick Stop Switch Quick Stop Switch Quick Stop Switch Din Symbols
Size Din Symbols LCD 02 x 64 Pixels
Weight ― Symbols 1-8 Din Symbols Symbols 1-10
Features
―― ―
243 x 77 x 41mm
480grams
• Output: 10mW @ 433-434MHz • Baud Rate: 9600 • Internal Antenna
• Battery: 3.7V / 1.8Ah • 13hr Operating Time
9 Button Hand Held Controllers Jupiter Joy-Stick Controllers
With Display
With Display With Display
Code 947823-400 947824-400 949767-401 949768-401 949769-401
Functions
9 x 2 Stage Buttons 9 x 2 Stage Buttons 3 Directions 2 Speed 3 Directions 2 Speed 3 Directions 2 Speed
Markings
Display 1 x Rotary Switch (4 Pos) 1 x Rotary Switch 2 Extra controls 2 Extra controls 5 Extra controls
Size
Weight Quick Stop Switch Quick Stop Switch
Features
DIN Symbols DIN Symbols DIN Symbols DIN Symbols DIN Symbols
― LCD Display 102 x 64px ― LCD Display 102 x 64px LCD Display 102 x 64px
243 x 77 x 41mm 260 x 165 x 150mm
480grams 520grams
• Output: 10mW @ 433-434MHz • Baud Rate: 9600 • Internal Antenna
• Battery: 3.7V / 1.8Ah • 13hr Operating Time
Jupiter Receiver - RX160 Accessories for Remotus - Hand Held
CRANE & VEHICLE CONTROLS Code 948470-800 Code 934158-000 935408-001 934157-001
No Of Outputs Code Belt Clip Vehicle Bracket Protective Bag
16: 4 C/O & 12 Open Contacts of
No Of Inputs which 6 are safety relays Accessories for Jupiter
1 Analogue 0(4)-20mA or 0/2-10V
Digital Inputs 1 Serial Input RS422/RS485 944204-000 947108-000
2 Opto Isolated for 24/48V AC/DC, Shoulder Strap Harness
Radio Freq. 115VAC or 230VAC 50/60 Hz
Mem Capacity 433-434 MHz
Protection 500 Transmitters
Casing IP67
Outputs For E/Stop Flame Retardent Plastic (UL 94 5VA)
Antenna 2 Safety Relays: 2 C/O Contacts
Size Internal
Weight 277 x 217 x 115mm
Supply Voltage 1.5kg
Consumption 24-230VAC/24VDC
Operating Temp MAX 12 VA
-25 to +55°C
279 For customised solutions contact ACDC Dynamics and Q
refer to shortform catalogue for complete range.
AIR LINE FILTERS & REGULATORS
Type Filter Regulator Filter/ TC Series Treatment TC Series Treatment Triplet
Regulator Oil Sprayer Dual Regulator & Air Filter/Regulator/Lubricator
Lubricator
Code 3/4” TF4000-06 TR4000-06 TW4000-06 TL4000-06 TC4010-06 TC4000-06
TW5000-10 TC5000-10
Code 1” TF5000-10 TR5000-10 TL5000-10 TC5010-10
TAD
Specifications Auto Drain Valve UW Series
• Filtration: 5µm Code 3/8” TAD402-03
• Applicable Pressure Range: 0-1.0MPa Code 1/2” TAD402-04
• Applicable Temperature: 0-60°C
• Gauge Port Size: G1/4
• Material (Body): Aluminium Alloy Die-cast
(Bowl): Polycarbonate (PC)
SOLENOID VALVES
US Series
USSC
USC US-10 US-25 UW-15 UW-25
UW-25 *
Code US-10 * US-15 * US-20 * US-25 * UW-15 * UW-20 *
Spare Coil Code
Spare Solenoid USC * UWC *
c/w Coil
Material of body USSC * UWSC *
Operating method
Pipe size Brass
Nominal diameter (mm)
Applicable fluid P lunger Pilot Film Pilot LIMIT & PRESSURE SWITCHES & SENSORS
Pressure range
Applicable temperature ZG3/8” ZG1/2” ZG3/4” ZG1” ZG1/2” ZG3/4” ZG1”
Operating voltage range
Minimum activating time 17 17 17 20 20 20 25
PS-02A Air, Water, Oil (50CST below) & Steam Air, Water, Oil (50CST below)
0.05 – 1.5Mpa 0 – 0.8Mpa
-5 to 185°C -5 to 99°C
± 10%
0.05S
*Add Voltage to Code: 12VDC, 24VDC, 24VAC, 110VAC, 230VAC
Pressure Switches
Pressure (Bar) Contact Rating Pipe Thread Code
Min. Max. (NPT)
PS-02B 1.4 2.8 2 Pole 20A N/C 1/4” PS-02A 2.8
2.1 3.5 2 Pole 20A N/C 1/4” PS-02A 3.5
2.8 4.3 2 Pole 20A N/C 1/4” PS-02A 4.3
3.5 5.6 2 Pole 20A N/C 1/4” PS-02B 5.6
4.9 7.2 2 Pole 20A N/C 1/4” PS-02B 7.2
CON 280
PROCESS GAUGES
Type Stainless Steel Case Robust Liquid Filled Economic
Code PBB- * - ** - *** - **** - ***** PBG- * - ** - *** - **** - ***** PBN- * - ** - *** - **** - *****
Connection This gauge is ideally suited to most For heavy duty services where vibration or For non-corrosive liquids and gases on light
A-Bottom Connection industrial applications where high accuracy shock of medium would cause excessive wear duty service in more corrosive environments.
D-Rear Connection and durability is required. Gauges are on a dry gauge or corrosive ambient Applications include coastal application for
available with either brass/bronze internals, conditions prevail. Applications include valve positioner and regulators, swimming
Case all stainless steel internals, or Manel hydraulic equipment, mining equipment and pool pumps and stationary irrigation systems.
Internals Bourdan tube and socket with stainless irrigation.
Range (Max) steel movement. Steel Black, Powder Coated
Temperature 304 SS, Crimped Bezel Brass
Accuracy Brush finish 304 SS, Bayonet Bezel Brass 6000 kPa
Configuration Available with either Brass/Bronze, or SS 6000 kPa -25℃ to 60℃
-25℃ to 60℃ 1.6% @ FSD
Thread 6000 kPa 1.6% @ FSD
Code Fitting -25℃ to 60℃
02 1/4 NPT 100Ø 1% @ FSD / 63Ø 1.6% @FSD
04 1/2 NPT
12 1/4 BSP Conn. A + D A+D Conn. A + D A+D Conn. A
14 1/2 BSP
Add to code
* Connection A (Bottom) & D (Rear) A (Bottom) & D (Rear) A (Bottom) only
** Add size (mm) 63 100 63 only 54 only
*** System material BB&SS BB BB
**** Thread size 02, 12 02, 04, 12, 14 02, 12 02, 12
***** Add pressure 100kPA, 160kPA, 250KPA, 400kPA, 600kPA, 1000kPA, 1600kPA, 2500kPA, 4000kPA, 6000kPA. Other ranges available on request.
Process Gauges Accessories
Steam Line Piping Valve Dairy Seals Chemical Seals Flanged Seals
LIMIT & PRESSURE SWITCHES & SENSORS NW40 NW50
Code U-TYPE Code VG ISOLATE Code NW40-* NW50-* XWD4-* NFD01-*
Code PIGTAIL Isolation valves and Material Grade 316 SS 316 Stainless Steel Grade 316 SS
gauge cocks to isolate Max Pressurer
• Steam line piping should pressure from gauge. Gauge Port 40 MPA 150 Mpa 150 Mpa
be installed on all live Application
steam applications to Equipped with a facility 1/4", NPT or BSP 1/4" or 1/2", NPT or BSP 1/4" and 1/2", NPT
protect the gauge from to vent the gauge. Thread Size
the high temperatures Suitable for use with Is used in health and Is used in applications Flanged seals, one for
encountered. gases, liquids and dairy application, can be where the process fluid continuous use for safety
• Available in either "pigtail” vapours. used for pulp/paper. (medium) is corrosive or concerns.
or “U-type” configurations viscous (could even Cleanout type for easy
for installation on horizontal Material - Brass For non-corrosive liquids contain waste particles) cleaning with flushing
or vertical line respectively and gases on light duty and could clog the connections available.
Material - Steel. service in more corrosive instruments internals.
environments. *Add Thread Type to Code:
02, 04
*Add Thread Type to Code: *Add Thread Type to Code:
02, 12 02, 04,12,14
281 RHE
PRESSURE TRANSMITTERS
Standard IP67 Mini Model IP67 Pressure Transmitter IP65
DIN Plug
To be ordered
separately
EDS-ST
Code SMP136-* SMP132-* PT1X*P**R01
Pressure Range
Output * Add to code 2, 5, 10, 20, 50 or 100 bar • Accuracy to better than 0.5%FS
Supply Voltage (including linearity and repeatability)
Media Temperature 4 - 20mA • Transducer rated at 50 million cycles
Thread • Metalwork made of Type 316
Overload Pressure 12 - 30VDC Stainless Steel
Accuracy • Protected against reverse voltage
Connector ˗25°C to 85°C and overvoltage
Seal Material • Protected against noise on the supply line
Housing Material G1/4, SS316 • Wide supply range, 8 to 36VDC -
Size (Ø x L)mm allows a wide range of load resistance
Application 1.5 x Full scale • Transducer is temperature compensated
by means of laser-trimmed resistors
0.5%F.S. • Operating temperature range from
0℃ to +85℃
DIN (4 PIN) Plug • Internal Trimpots for field calibration
Fluoro Elastomer
Aluminium
Ø27mm x 97mm Ø48mm x 74mm
Machine Tools Petroleum Industry Mechanical Engineering
Environmental Chemical Industry Machine tools
Dry Gases etc Sewage plants etc Hydraulics
Hi-Temperature IP67 Flush Seal IP67 General Purpose IP68
DIN Plug SMP135-* SMP134-* LLS2.5/5 LLS10/15 GENERAL SPECIFICATIONS
To be ordered 3 bar 10 bar Output: 4 - 20mA
separately * Add to code 2, 5, 10, 20, 50 or 100 bar 4 - 20mA Excitation: 8 - 36V DC
15 - 30VDC Accuracy (BFSL):< 0.5% FS
EDS-ST 4 - 20mA 0°C - 70°C Compensated Temp. Range: 0º to 85º C LIMIT & PRESSURE SWITCHES & SENSORS
1/4" Gas Temperature error zero: < -0,02% FS / K
Code 12 - 30VDC 6 bar 20 bar Temperature error span: < -0,01% FS / K
Pressure Range 1.5%F.S. (0-70ºC)
Output ˗60°C to 200°C ˗25°C to 85°C Ingress protection: IP65
Supply Voltage Cable 5m Cable 15m Burst pressure: 2.5 x FS (except when
Media Temperature M20X1,5 G1/2 (50 & 100Bar = G3/4) Ceramic indicated)
Thread (SS316) SS314 Wetted Parts/Connection: 316 Stainless
Overload Pressure 1.5 x Full scale steel, ceramic, Nitrile (Specify media where
Accuracy Ø30mm x 54mm Nitrile is not compatible)
Connector 0.5%F.S. Pumps / Fluids WIRING CONNECTIONS
Seal Material Compressors 1 Red: + Us
Housing Material Gas 2 Black: - Vs
Size (Ø x L)mm 3 Yellow: GND
Application
* **
Code Transducer Range Code Fitting
DIN (4 PIN) Plug 0010 1 Bar 02 1/4” NPT
0040 4 Bar 04 1/2” NPT
SS316 Fluoro Elastomer 0060 6 Bar 12 1/4” BSP
Aluminium 0100 10 Bar 14 1/2” BSP
0160 16 Bar
0250 25 Bar Other options available
0400 40 Bar
Ø48mm x 219mm Ø27mm x 70mm 1000 100 Bar
4000 400 Bar
Steam / Heated process Machine tools
Thermal energy process Mechanical Engineering Other options available
Process control Hydraulics/Pneumatics PRODUCT TRANS PRESSURE FITTING
RANGE DUCER
RANGE P ** R01
PT1X
*
CON 282
ELECTRONIC AIR PRESSURE SENSORS & SWITCHES
Electronic Air Pressure Controllers
Code Code Cut-out- Cut-in- Maximum Repeat
pressure pressure pressure Accuracy
Relay Output Supply 4-20mA Supply Supply at 25°C
0.2-2 bar 0-50% of
1C/O only Output 0.5-10 bar cut-out
1-16 bar pressure
EDR-2 230VAC – – 3 bar +/-0.05 bar
– – EDI-10 12-30VAC 25 bar +/-0.1 bar
EDR-16 230VAC EDI-16 12-30VDC 25 bar +/-0.15 bar
Note: 4mA = 0 bar. 20mA = measuring range highest value
EDR & EDI • Accurate compressor and process control • User friendly menu programming
• Electronic pressure switch with integrated pressure sensor • Relay output – (All models) 6A @ 250VAC
• Push-on connector for air tube inlet (Festo PAN 6 x 16mm) • 0-10V Analogue output and digital LED display
• Adjustable relay set point and hysteresis
• Fail safe (EDRA only)
• Din rail mounting
Electronic Pressure Sensor
Code NPN N/O PSA-01 PSA-1
Code PNP N/O PSA-01P PSA-1P
Pressure Range 0-100.0kPa (0-1.000 Bar) 0-1000.0kPa (0-10.00 Bar)
Specifications 12V to 24VDC ± 10%. 50mA • Hysteresis: 1 digit (2 digit/psi) fixed
Max. 100mA 30VDC • R epeat Error: ± 0.2% F.S. ± 1 digit
• Power Supply: 1V-5VDC ± 2% F.S. • Response Time: Selectable 2.5ms, 5ms,
• O utput Current: kPa, kfg/cm2, bar, psi 100ms, 500ms
• Analog Output: 30x30x38.5(D)mm • Short Circuit Protection: Built-in
• Pressure Display:
• Size:
Accessories
Code Description
PS-01 Bracket for panel mount. Size of cutout 36X36mm
PS-02 Clear protection cover
2-Wire Electronic Air Pressure Transducer IP65
• Accurate process control • Service friendly plug-in electrical connection
• 2-Wire device installs directly on the machinery • Converts measured pressure to 4-20mA
• Ceramic sensor technology
Code Description Pipe Measuring Output Repeat Supply
Thread Range Accuracy
EDS-16 Transducer External G1/4" 0-16 bar 4-20mA +/-1% 11-30VDC
EDS-ST Connection plug DIN3852 Form E
EDS-16
Pressure Switch Diagrams
The co-ordinates of a cut out and cut in pressure must lie within the shaded area for the switch to be suitable for the application.
LIMIT & PRESSURE SWITCHES & SENSORS EDS-ST
283 CON
PRESSURE SWITCHES
Direct Motor Switching Ui = 500V
Cut-out Contacts Features Pipe Code Code with
Pressure (Bar) AC3 Thread Auto-Off
Min Max Diff Switch
MDR1 F or use with air, water, mineral oils, sea/salt water, butane, acetylene, carbon dioxide etc.
Medium temperature: Air -5 to +80°C. Water +70°C max. IP44
Contacts 2 N.C. Ith 20Amps, 2,2/4kW @ 240V. Bursting strength Pz >35 Bar.
MDR1/11 2.5 6.0 Adj 1ph 4.0kW For Pumps only Factory set 1.5-3 Bar 1/4" BSP MDR1/6/DIF –
2.5 11.0 2 Bar 1ph 2.2kW For Compressor only Factory set 6-8 Bar 1/4" BSP MDR1/11 MDR1/11/EA
MDR2 F or use with air, water.
Medium temperature: Water +80°C max. IP44
Contacts 2 N.C. Ith 20Amps, AC3 2.2kW @ 240V. Bursting strength Pz >35 Bar.
1.5 7.0 Adj 1ph 2.2kW 1/4" BSP MDR2/6 –
4.0 12.0 Adj 1ph 2.2kW 1/4" BSP MDR2/11 MDR2/11/EA
MDR1/11/EA MDR4 F or use with air, water.
Medium temperature: Water +80°C max. IP44
Contacts 3 N.C. Ith 20Amps, AC3 5.5kW @ 400V. Bursting strength Pz >35 Bar.
1.5 6.0 Adj 3ph 5.5kW 1/2" BSP MDR4/6 MDR4/6/EA4
4.0 11.0 Adj 3ph 5.5kW 1/2" BSP MDR4/11 MDR4/11/EA4
6.0 16.0 Adj 3ph 5.5kW 1/2" BSP MDR4/16 MDR4/16/EA4
MDR5 F or use with air, water, sea water, petrol, diesel, natural gas, butane, carbon dioxide etc.
Medium temperature: Air -5 to +80°C. Water +80°C max. IP54
Contacts 3 N.C. Ith 25Amps, AC3 5.5kW @ 400V. Bursting strength Pz >40 Bar.
MDR2/6 or /11 2.0 8.0 Adj 3ph 5.5kW 1/2" BSP MDR5/8
2.5 16.0 Adj 3ph 5.5kW 1/2" BSP MDR5/16
Fitted with Unloader Valve, Overload & Start/Stop Buttons
MDR5/8 Range: 2 .4-4.2A 1/2" BSP MDR5/16/4.2
MDR2 or 4/EA or /16 4.0-7.0A 1/2" BSP MDR5/16/7
6.1-10.3A 1/2" BSP MDR5/16/10
9.0-14.0A 1/2" BSP MDR5/16/14
11.0-18.0A 1/2" BSP MDR5/16/18
With Overload
Accessories
Spare Covers for MDR5
Description Code Unloader Valve Code
plain H5-COVER EV1S For MDR1 EV1S
with On/Off buttons H5K-COVER EV2 For MDR2 EV2
EV4 For MDR4/43 EV4
H5-COVER H5K-COVER EV5 For MDR5 EV05
Control Circuit Switching 10Amp 250VAC Ui = 400V IP65
MDR43 F or use with a wide range of mediums including air, water, oils and refrigerants. LIMIT & PRESSURE SWITCHES & SENSORS
Medium temperature: Air -25 to +100°C. Water +100°C max. IP54
MDR43 Cut-out Pressure (Bar) Contacts Bursting Pipe Thread Code
Min Max Diff Strength
1 NO + 1 NC 1/4" BSP MDR43/3
0.5 3.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4" BSP MDR43/6
2.5 6.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4" BSP MDR43/11
5.0 11.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4" BSP MDR43/16
8.0 16 Adj Pz >60 Bar
MDR-F MDR-F H igh pressure range – for use with air, water, sea water, petrol, diesel, natural gas butane, propane,
nitrogen etc.
Medium temperature: +70°C max. IP54
0.5 8.0 Adj 1 C/O 10A Pz >40 Bar 3/8" BSP MDR-F8H-S
1.0 16.0 Adj 1 C/O 10A Pz >48 Bar 3/8" BSP MDR-F16H-S
2.0 32.0 Adj 1 C/O 10A Pz >64 Bar 3/8" BSP MDR-F32H-S
8.0 60.0 Adj 1 C/O 10A Pz >120 Bar 3/8" BSP MDR-F60HH-S
See page 283 for pressure diagrams. CON 284
LIMIT SWITCHES
Steel Type AH8 (28mm) IP65
• Contact: NC & NO 5A • Cable entry: Rubber Grommet
Code AH8111 AH8112 AH8122 AH8104 AH8107 AH8108 AH8166 AH8101 AH8169
180° Tilt Wobble 180° Tilt
Steel Type WL5 (40mm) IP65 180° Tilt Maintained Pull Switch
• Contact: NC & NO 10A • Cable entry: 20mm
Hole centres:
Pushbutton Pushroller Rollerball 20-22mm
Code WL5101 WL5102 WL5103 WL5104 WL5106 WL5107-2 WL5108-2 WL5105 AP5-T98
Compact Enclosed Type AH-7 IP65
Code AH-7100 AH-7110 AH-7310 AH-7311
LIMIT & PRESSURE SWITCHES & SENSORS Code AH-7312 AH-7120 AH-7140 AH-7121
Mounting holes
Code AH-7141 AH-7124 AH-7144
Specifications • Service life: Mechanically: 1 000 000 operations min
Electrically: 100 000 operations min
• Contact resistance: 25mΩ max (initial) • Current rating: 10A @ 250VAC C/O
• Insulation resistance: 100MΩ min (at 500VDC)
• Dielectric strength: 1 000VAC 50/60Hz for 1 min
285 HIG
LIMIT SWITCHES
Plastic Type AP1 – 30mm Width IP65
• EN50047
• Contact:
NC & NO
10A@24VAC
3A@240VAC
• Cable entry:
M20x1.5
Code AP5T11 AP5T13 AP5T31 AP5T41 AP5T51 AP5T52 AP5T71 AP5T91 AP5T92
Plastic Type BP1 – 40mm Width IP65
• EN50041
• Contact:
NC & NO
10A@24VAC
3A@240VAC
• Cable entry:
M20x1.5
Code BP5H12 BP5H19 BP5H33 BP5H43 BP5H53 BP5H54 BP5H91 BP5H92 BP5H93
Plastic Type DP1 – 50mm Width IP65
• C ontact:
1N/O & 1NC
10A@24VAC
3A@240VAC
• M20x1.5
Cable entry
• 2 x cable
entries
Code DP5T11 DP5T13 DP5T31 DP5T41 DP5T51 DP5T52 DP5T71 DP5T91 DP5T92 LIMIT & PRESSURE SWITCHES & SENSORS
Metal Pre-Wired • Type EM1 30W x 50H (mm) IP67 • Type EM2 33W x 70H (mm) IP67
• IEC 947-1
• E N60947-1
• Contact: 1N/O
& 1N/C
5A@24VAC
1A@240VAC
• Cable: 1m
EM2 mounting holes
EM1 mounting holes EM1G11Z EM1G12Z EM1G14Z EM1G21Z EM1G22Z EM1G24Z EM1G41Z EM1G42Z
Code side cable EM2G11Z EM2G12Z EM2G14Z EM2G21Z EM2G22Z EM2G24Z EM2G41Z EM2G42Z
Code bottom cable
HIG 286
MICRO SWITCHES
General purpose Z-type
Code Z15G-1701 Z15G-1702 Z15G-1703 Z15G-1704
Code Z15G-1744 Z15G-1300 Z15G-1305 Z15G-1306
Code Z15G-1307 Z15G-1705 Z15G-1308 Z15G-1318
Mounting holes
Specifications Terminal Cover for
• Contact resistance: 15mΩ max (initial) Z-type Micro Switches
• Insulation resistance: 100MΩ min (at 500VDC)
• Dielectric strength: 1 000VAC 50/60Hz for 1 min Z15G-1307
• Service life: Mechanically: 1 000 000 operations p/min 50mm
Electrically: 100 000 operations p/min
• Current rating: 15A @ 250VAC C/O
Type VS Micro switch (High mechanical life)
27mm
Code VS15P01C VS15P02C VS15P03C VS15P04C
Low torque
LIMIT & PRESSURE SWITCHES & SENSORS Code VS15P05C VS15P06C VS15P07C P-CS-71
Push Buttons
Specifications
Contact resistance: 15mΩ max (initial) Fits onto VS15P01C Micro Switch Hole Size 10mm
Insulation resistance: 100MΩ min (at 500VDC)
Dielectric strength: 1 000VAC 50/60Hz for 1 min
Service life: Mechanically: 1 000 000 operations p/min
Electrically: 100 000 operations p/min
Current rating: VS: 1C/O 15A @ 250V
P-CS: 1C/O 5A @ 250V
Code VAQ-5-* VAQ-4-* AB6161-* AB5151-*
Mounting holes HIG Hole Size 12mm
*Add colour of button: ●R, ● Y, ● GN
287
LIMIT & FOOT SWITCHES
Heavy Duty
Code 1NO + 1NC FS-1 FS-2 FS-3 FS-4 (SPDT)
FS-4/DP (DPDT)
Code 2NO + 2NC – – –
15A 250VAC
Contacts 10A 250VAC (SPDT) 10A 250V (SPDT) 10A 250V (SPDT) Aluminium
Enclosure material Steel cover Poly-carb Aluminium Not supplied (16mm entry)
Cable/Entry PVC 0.75mm x 3 core PVC 0.75mm x 3 core PVC 0.75mm x 3 core IP54
IP rating IP40 IP40 IP40 Z15G-1704
Spare contact 1NO + 1NC – – –
Footswitch - With locking device in neutral Steel Mounting Frames Safety Limit Switches
IP67
position (Pedal in the up position) Without foot switch
400mm
WW
Code 1NO+1NC FS-PS1211 (SPDT) Code Description Width
Code 2NO+2NC FS-PS1213 (DPDT)
Contacts 10A 250VAC PD-1000 For 2 foot 350mm
Code
Enclosure material Shock resistant ABS switches EDR-6-1-22 EDR-6-1-27 EDR-6-1-32
700mm
IP rating IP65 For 4 foot 1NO + 1NC (3A 230VAC)
Cable/Entry Cable Entry 20mm
Spare contact for Not supplied (PG16 entry)
Z11 PD-1002 switches
Latching limit switch manual pull to reset
1NO+1NC
Safety Limit Switches Keys
K101 LIMIT & PRESSURE SWITCHES & SENSORS
90˚ adjustable head 360˚ fully turnable head K100
Code SP5K20 SP5K120 K101 K100
Key
Contact K101/K100 Key fits on front or top of the limit switches
Enclosure
Dimensions (mm) 1NO + 1NC 3A@240VAC Order key separately
IP65 Plastic body
30 x 30 x 90 – M20 entry
HIG 288
ROPE PULL SWITCHES
Rope Mounting holes Contacts Rope Pull Switches
Pull for PL-967 1NO + 1NC
Latching Housing IP65 Code Description
3A/400VAC
PL-967 4kg rope pull switch
Latching on rope break
Rope Accessories PL-967-7.5KG 7.5kg rope pull switch
PL-967-15KG 15kg rope pull switch
Features Safety Rope Break Switches
• Complies to IEC-947-5-1
• 1NO + 1NC Positive Action With reset SM5K98X11 SBM5K99X11
• AC-15 = 3A at 230V. ui = 690V
• For cable lengths up to 6 metres Without reset SM5K96X11 SBM5K97X11
MET Not latching Weight 4.7kg 6.7kg
Dimensions 30 x 30 x 143 40 x 44 x 162
M20 entry M20 entry
IP Rating IP65 IP66
Enclosure Die-cast Body Die-cast Body
Code PWR SB209331/6 SB209332/6.5 SB209333/M8 SB209333/M10 SB209333/M12 SB209336/8
M8 Eye bolt
Description Steel Wire. PVC sheathed Thimble Clamp M10 Eye bolt M12 Eye bolt Tensioner
rope. 100m. Ø5mm Red. 6mm 6.5mm 8mm
CONVEYORS SAFETY SWITCHES
Safety Cable Pull Switches Belt Alignment Switch Speed Monitor
IP67 IP67 IP65
Code SRS SRT ED400
Switching Capacity SPDT x 2 10A@250VAC SPDT x 2 10A@250VAC
Action Force 49 ± 9.8n 3.4-5.4N.m Specifications
(5±1kgf.m) (0.35-0.55kgf.m)
Reset Manual Auto • Speed: 0~999rpm
Ambient Temp -20-60˚C -20-60˚C • 7-seg LED display: 0~999
Enclosure Material Die-Cast Aluminium Die-Cast Aluminium • Alarm set point: 1~1999rpm
Weight Approx. 2.9kg 2.9kg • Rotate direction: CW or CCW
Certified for use in • Alarm: Underspeed, Standstill, Reverse, Power Failure
LIMIT & PRESSURE SWITCHES & SENSORS Zone 21/22 Standard Slack Rope Ripped/Torn • Speed output: 4~20mA
Conveyor Belt Conveyor Belt Conveyor Belt • Supply: 85~265VAC
• Ambient Temperature: -20˚~70˚C
Trip Switch Trip Switch Trip Switch • Housing: Die-cast Aluminium
Conveyor Belt Alignment
Switch
CHW53201
Code CHW93053 CHW93058
Type 1NO/NC 2NO/2NC
PT125CW5000 CHW53198 CHW53198A CHW53198B Switching Capacity 3A @ 230VAC 10A @ 230VAC
CHW53197 - Protection rating IP65
Code Single End CHW53197A Cable Entries
Code Double End 10A @ 230VAC HIG 1 x M20
Rated Continuous Current
Protection rating IP66 Accessories for Conveyor Belt Trip Switches
Cable Entries 3 x M20
Code Description
289 CHW53201 Padlock Attachment
PT125CW5000 Pigtail M10 x 125mm
COMPACT RECTANGULAR/SQUARE INDUCTIVE SENSORS IP67
3 Wire DC Inductive Sensors 2 Wire DC
Inductive
NPN NO PS17-5DN PS17-8DN PFI25-8DN PSN25-5DN PSN30-10DN PSN30-15DN PSN40-20DN PS50-30DN NO Output
PNP NO PS17-5DP PS17-8DP PFI25-8DP PSN25-5DP PST17-5DO
NPN NC PS17-5DN2 PS17-8DN2 PFI25-8DN2 PSN25-5DN2 PSN30-10DP PSN30-15DP PSN40-20DP PS50-30DP NC Output
PNP NC – – PFI25-8DP2 PSN25-5DP2 PST17-5DC
PSN30-10DN2 PSN30-15DN2 – PS50-30DN2
PSN30-10DP2 PSN30-15DP2 PSN40-20DP2 PS50-30DP2
Switching distance 5mm ±10% 8mm ±10% 5mm ±10% 10mm ±10% 15mm ±10% 20mm ±10% 30mm ±10% 5mm ±10%
Hysteresis Max. 10% of switching distance
Standard detecting 18 x (1Ir8onx ) 25 x 25 x 1mm (Iron) 30 x 30 x 45 x 45 x 60 x 60 x 90 x 90 x 18 x 18 x
target 1mm 1mm (Iron) 1mm (Iron) 1mm (Iron) 1mm (Iron) 1mm (Iron)
Response frequency 700Hz 200Hz 300Hz 250Hz 200Hz 100Hz 50Hz
Dimensions 17 x 17 x 31 26 x 10 x 49 25 x 25 x 39 30 x 30 x 53 40 x 40 x 53 53 x 53 x 35 17 x 17 x 31
Protection circuit Surge protection circuit. Surge protection circuit. Reverse polarity protection. Surge
Reverse polarity protection Overload & short-circuit protection Protection Circuit
Power supply 12-24VDC
(Operation voltage) (10-30VDC)
Leakage current Max. 10mA
Residual voltage Max. 1.5V Max. 4V
Affection by Temp. -25 to +70°C
Control output 200mA 2-100mA
Insulation resistance Min. 50MΩ (at 500VDC)
Operation indicator (Red LED)
Indicator
Ambient temperature -25 – +70°C (at non-freezing status)
2 Wire AC Inductive Sensors
NO Output PSN25-5AO PSN30-10AO PSN30-15AO PSN40-20AO
NC Output PSN25-5AC PSN30-10AC PSN30-15AC PSN40-20AC
Switching distance 5mm ±10% 10mm ±10% 15mm ±10% 20mm ±10%
Hysteresis Max. 10% of switching distance
Standard detecting 25 x 25 x 1mm 30 x 30 x 1mm 45 x 45 x 1mm 60 x 60 x 1mm
(Iron) (Iron) (Iron)
target (Iron)
Dimensions 25 x 25 x 39 30 x 30 x 53 30 x 30 x 53 40 x 40 x 53
Power supply 100-240VAC
(Operation voltage) (85-264VAC)
Leakage current Max. 2.5mA
Response frequency 20Hz
Residual voltage Max. 10V
Affection by Temp. ±10% Max. for detecting distance at +20°C within temperature range of -25 – +70°C LIMIT & PRESSURE SWITCHES & SENSORS
Control output 5-200mA
Insulation resistance Min. 50MΩ (at 500VDC)
Indicator Operation indicator (Red LED)
Ambient temperature -25 to +70°C (at non-freezing status)
Protection Circuit Surge protection circuit
AUTO DOOR SENSOR
Code ADS-A
Supply Voltage 24-240VAC
Relay Output 0.1A @ 50VDC
Mounting Height 2-2.7m (max. detecting distance: 3m)
Output Delay Time 2/7/15 sec selectable by dip switch
Detection Four angles for front detection area, 7.5°, 14.5°,
21.5°, 28.5°
Right/Left detection area elimination function
Also see page 316
SCA 290
MAGNETIC PROXIMITY SWITCHES IP67
Reed Contact Magnetic Switches (Cable length 2m)
Nickel Plated Brass Housing SM19 SM02
SM21
SM22
Plastic Housing
Nickel Plated Brass Housing
Diameter/Length Code Amps Code Amps Code Amps Code Amps
N/O 30VDC 250VAC N/O+N/C 30VDC 250VAC N/O 30VDC 250VAC N/O + N/C 30VDC 250VAC
0.1A 0.01A –– –– ––
8 30mm SM03 0.33A 0.04A – 0.33A 0.04A – –– – ––
–– SM06 0.1A 0.01A – 1.6A 0.2A – ––
10 30mm SM05 –– SM08 –– SM09 3A 0.4A – 3A 0.4A
–– – –– SM13 3A 0.4A SM14 2A 0.25A
12 40mm – – SM17 SM18
12 70mm –
18 70mm –
Plastic Housing N/O N/O+N/C N/O Bistable N/O
Diameter/Length
6 38mm – –– SM02 0.1A 0.01A – –– – – –
12 100mm SM19 1.6A 0.2A –– – SM21 0.4A
Specifications 3A 0.4A SM22 3A
Wiring Diagrams
• Max Voltage: 230VAC
• Switching Frequency: 200Hz
• Delay on Activation: N/O + N/C
• Repeatability: 2mS N/O
• Temperature Limits: ± 0.3mm
-20 to + 60 °C
• Cable section (N/O): 2 x 0.50mm2
• Cable section (N/O N/C): 3 x 0.50mm2
Hall Effect Magnetic Proximity Switches 12-30VDC IP67
Type Code Bi-lateral Sensing Code Frontal Sensing • Voltage 12-30VDC Bi-lateral sensing
• Fast 50µsec on/off Frontal sensing
12mm 18mm 12mm 18mm • LED yellow: output on
• LED green: supply on Bi-lateral sensing
PNP N/O - HS05B HS03F HS05F • Switching frequency 10kHz
• Max output 200mA
PNP N/C HS04B HS06B HS04F HS06F • Nickel Plated Brass housing
• Cable length 2m
Reed Contact Switch / Magnet Switching distances (mm)
MG01 MG02 MG03 MG04 MG05
Distance Hysteresis Distance Hysteresis Distance Hysteresis Distance Hysteresis Distance Hysteresis
LIMIT & PRESSURE SWITCHES & SENSORS Diameter 6 24 5 22 5 6 2.5 32 5 29 5
Diameter 8 24 5 22 5 6 2.5 32 5 29 5
Diameter 10 24 5 22 5 6 2.5 32 5 29 5
Diameter 12 (L=40mm) 24 5 22 5 6 2.5 22 9 20 9
Diameter 12 (L=70mm) 12 7 10 6 – – 22 9 20 9
Diameter 18 12 7 10 6 – – 22 9 20 9
Warning: The data specified in this table has an approximate value because it depends on the magnet position, the material on which it is applied (ferromagnetic or
not) and because it is related to the magnet during the frontal approach. Reed contact sensors can also be activated laterally considering that switching distances are
always influenced by the magnet position, orientation and the material on which it is applied (ferromagnetic or not).
Magnets Dimensions (mm)
291 DAT
SQUARE INDUCTIVE PROXIMITY SWITCHES IP67
Square 40x40mm AS80 Square 80x80mm
• PBT (resin) or Nickel-plated 65 80
Brass Housing
• Operating Distance 1.5 ... 15mm –
• 40x40mm or 8x8mm dimension 50mm
• Cable, M8/M12 Connector or 12-48VDC
Terminal Block 200mA
• 2 or 3 Wires
• PNP, PNP/NPN, NO, NC, NO/NC –
100Hz
Short Housing M12 Plug* Cable
Available Shielded Not Shielded Shielded Not Shielded –
Switching Distance (Sn) 1.5mm
Operating Voltage 15mm 30mm 15mm 30mm 10-30VDC
Max Output Current 200mA
Operation LED 10-30VDC 20-250 VAC/DC Yellow
Switching Frequency 500Hz
Connection 200mA 200mA *M8 Plug, Cable
Dimensions Yes Yes
100Hz 25Hz AC; 40Hz Dc Terminal
M12 Plug*, Terminal Block Block
40 LED 30
46 60 PG 13.5
40 118 11
65 23 40
40
Ø22.4 15
20
34 M12x1
OUTPUT: 40 26
PNP NO –––– – IS-88-Q1-03*
AS80-50DN3 –
NPN NO + NC IS-40-W6-03 IS-40-Y6-03 – – –
– –
NPN NO + NC Short Housing M12 Plug* IS-40-X6-S2 – – – AS80-50P3 –
–
PNP NO + NC IS-40-W5-03 IS-40-Y5-03 – – – –
–
PNP NO + NC Short Housing M12 Plug* IS-40-X5-S2 – – – –
2 Wires AC/DC NO – – IS-40-W7-03 IS-40-Y7-03 LIMIT & PRESSURE SWITCHES & SENSORS
2 Wires AC/DC NC – – IS-40-W8-03 IS-40-Y8-03
*For M8 plug type replace 03 with S1 e.g. IS-88-Q1-S1
For sensor cable and accessories see pages 329-332
DC SENSOR TESTER
For M12 Connector, Cable & Terminal DC Sensors
Code Description
ST-02 • PNP (sourcing) and NPN (sinking) Testing
• M12-5-Pin Plug Input
• Terminal Inputs
• Two Output LED's
• Battery Powered
DAT 292
DC 2 WIRE 10-30VDC INDUCTIVE PROXIMITY SWITCHES IP67
DC DC DC
Diameter Ø12 Ø18 Ø30
Shielded Non Shielded
• Nominal Voltage: 10-30VDC
• Max. Output Current: 100mA
• Temperature Range: -25 to 70°C
• Housing Material: Nickel Plated Brass
• Cost Effective
Switching Distance 2mm 4mm 5mm 8mm 10mm 15mm
Operation LED Yellow Yellow Yellow
Switching Frequency 1000Hz 1000Hz View of male 300Hz
Cable Length 2m 2m connector 2m
Wiring Diagrams M12
BROWN
For sensor cable and
accessories see pages 329-332 NO Configuration of Contacts
BLUE N. contacts
BLUE Available
1 2 3 4
NC NO + _
NC _ +
BROWN
OUTPUT: IS-12-A9-03 IS-12-C9-03 IS-18-A9-03 IS-18-C9-03 IS-30-A9-03 IS-30-C9-03
NO-NC programmable Cable IS-12-A9-S2 IS-12-C9-S2 IS-18-A9-S2 IS-18-C9-S2 IS-30-A9-S2 IS-30-C9-S2
NO-NC programmable (M12 connector)
SPECIAL DC INDUCTIVE PROXIMITY SWITCHES IP67
Weld Field Immune Metal Face
Diameter Ø12 Ø18 Ø12 Ø18
Shielded Non Shielded
• Nominal Voltage: 10-30VDC
• Max. Output Current: 200mA
• Temp. Range: -25 to 70°C
• Housing Material: Stainless
Steel
• Weld field immune is
intrinsically safe and used in
welding bays.
LIMIT & PRESSURE SWITCHES & SENSORS Switching Distance 2mm 4mm 5mm 8mm 2mm 4mm 5mm 8mm
Operation LED Present 1000Hz Present 500Hz Present 1000Hz Present 500Hz
Switching Frequency 2000Hz 1000Hz 2000Hz 1000Hz
Active Face Material ETFE ETFE Stainless Steel Stainless Steel
Wiring Diagrams
View of quadripole Configuration of Contacts
For sensor cable and male connector
accessories see M12 N. contacts
pages 329-332
Available 1 2 3 4
NO + - no
OUTPUT: IS-F12-S1-S2 IS-F12-T1-S2 IS-F18-S1-S2 IS-F18-T1-S2 IS-12-I1-S2 IS-12-L1-S2 IS-18-I1-S2 IS-18-L1-S2
PNP NO M12 Plug
293 DAT
24-250VAC/VDC INDUCTIVE PROXIMITY SWITCHES NO OR NC IP67
Diameter Ø 12 Ø 18 Ø 30
Shielded Non Shielded
• Current output 200mA max
Switching Distance 2mm 4mm 4mm 8mm 5mm 8mm 8mm 16mm 10mm 16mm 15mm 25mm
Nominal Voltage 20-250VAC/VDC 20-250VAC/VDC
Max Output Current 20-250VAC/VDC 200mA 200mA
Switching Frequency 25Hz AC/ 35Hz DC 25Hz AC/ 35Hz DC
Operating Temperature 200mA -25°C to 75°C -25°C to 75°C
Sensing Face PBT PBT
Housing 25Hz AC/ 35Hz DC Nickel Plated Brass Nickel Plated Brass
Connection Cable 2m, M12 Plug Cable 2m, M12 Plug
Operation LED -25°C to 75°C Present Present
Wiring Diagram
PBT
Nickel Plated Brass
Cable 2m, M12 Plug
Present
Dimensions
M12x1 M12x1 M12x1 M12x1 M18x1 M18x1 M18x1 M18x1 M30x1,5 M30x1,5 M30x1,5 M30x1,5
60 52 8 26 55 5 43 12 55 40 15 15 15
42 34 60 8 79 LEDx4 64 15
79
26 15 15
68 38 79
M12 Connector LED LED LED
LED LED
LED LEDx4 LEDx4 M12x1 LEDx4 M12x1
LEDx4 15 15
OUTPUT: M12x1
LEDx4
15 15
M12x1 M12x1 M12x1
NO Output (Cable Type) IPS12-S2UO60*-A2P IPS12-N4UO60*-A2P IPS18-S5UO55**-A2P IPS18-N8UO55**-A2P IPS30-S10UO55**-A2P IPS30-N15UO55**-A2P
Double Sensing IPS12-S4UO60*-A2P IPS12-N8UO60*-A2P IPS18-S8UO55**-A2P IPS18-N16UO55**-A2P IPS30-S16UO55**-A2P IPS30-N25UO55**-A2P
NC Output (Cable Type) IPS12-S2UC60*-A2P IPS12-N4UC60*-A2P IPS18-S5UC55**-A2P IPS18-N8UC55**-A2P IPS30-S10UC55**-A2P IPS30-N15UC55**-A2P
Double Sensing IPS12-S4UC60*-A2P IPS12-N8UC60*-A2P IPS18-S8UC55**-A2P IPS18-N16UC55**-A2P IPS30-S16UC55**-A2P IPS30-N25UC55**-A2P
*For plug type replace 0-A2P with 8-A12 For sensor cable and accessories see pages 329-332
**For plug type replace 55-A2P with 79-A12
ANALOG INDUCTIVE PROXIMITY SWITCHES 0-10V 4-20mA IP67
Diameter Ø 12 Ø 18 Ø 30
Shielded Non Shielded 0.6-6mm 3.1-10mm 3.1-10mm 7.3-20mm 7.3-20mm 17.6-40mm
Measuring Distance
Nominal Voltage 18-30VDC 18-30VDC 18-30VDC
Load Resistor
Output Following Frequency V: > 2 kOhm, A: 400 Ohm V: > 2 kOhm, A: 400 Ohm V: > 2 kOhm, A: 400 Ohm LIMIT & PRESSURE SWITCHES & SENSORS
Operating Temperature
Sensing Face 100Hz 100Hz 100Hz
Housing
Connection 0°C to 70°C 0°C to 70°C 0°C to 70°C
Wiring Diagram
PBT PBT PBT
Nickel Plated Brass Nickel Plated Brass Nickel Plated Brass
Cable 2m Cable 2m Cable 2m
Dimensions
OUTPUT:
Voltage 0-10V IA12-S6V010-2NP IA12-N10V010-2NP IA18-S10V010-2NP IA18-N20V010-2NP IA30-S20V010-2NP IA30-N40V010-2NP
IA12-N10I420-2NP IA18-S10I420-2NP IA18-N20I420-2NP IA30-S20I420-2NP IA30-N40I420-2NP
Current 4-20mA IA12-S6I420-2NP
SCA 294
DC INDUCTIVE PROXIMITY SWITCHES STANDARD & SHORT »
Diameter NPN or PNP Ø5 Ø6.5 DC Ø8
Shielded Non Shielded
• Nominal Voltage 10-30VDC
• 4 Wire programing type
• 3 Wire plug and cable type
• Standard & Short Housing versions
For Sensor Cable & Acces-
sories see pages 329-332
Nominal Switching Distance (Sn) 0.8mm 1.5mm 2mm 2mm
200mA
Max. Output Current 100mA 200mA Present (Yellow)
1000Hz
Operation LED Present Present -20 to 60°C
2m
Switching Frequency 2000Hz 1000Hz Nickel plated brass
Temperature Limits -25 to 60°C -25 to 70°C *For plug type M12 change 'S1' to 'S2' e.g. IS-08-G3-S2
Cable Length 2m 2m
Housing Material Stainless Steel Nickel-plated brass
View of male connector M12 Wiring Diagrams *For plug type M8 change '03' to 'S1' e.g. IS-65-A3-S1
4
13
Contacts Numbers
OUTPUT: Available 1 3 4 3 wire sensors
NPN/PNP BROWN BLUE BLACK
M8 Plug Type
+ __ NO/NC
NPN & PNP, (NO & NC) Cable type (4 Wire) – – – Cable Type
– –
NPN & PNP, (NO & NC) M12 connector (4 Wire) – IS-65-A1-03* IS-65-C1-03*
IS-65-A2-03* IS-65-C2-03*
PNP NO output (3 Wire) IS-05-A1-03* IS-65-A3-03* IS-65-C3-03* IS-08-G1-03 IS-08-G1-S1*
IS-65-A4-03* IS-65-C4-03* IS-08-G2-03 IS-08-G2-S1*
PNP NC output (3 Wire) – IS-08-G3-03 IS-08-G3-S1*
IS-08-G4-03 IS-08-G4-S1*
NPN NO output (3 Wire) IS-05-A3-03*
NPN NC output (3 Wire) –
NAMUR INDUCTIVE PROXIMITY SWITCHES IP67
Diameter DC DC DC DC Ø30
Ø8 Ø12 Ø18
Shielded Non Shielded
LIMIT & PRESSURE SWITCHES & SENSORS Switching Distance (± 20%) 1mm 2mm 2mm 4mm 5mm 8mm 10mm 15mm
Nominal Voltage (Load Resistance 1K) 7.7-9VDC 7.7-9VDC 7.7-9VDC 7.7-9VDC
Supply Voltage 5-24VDC 5-24VDC 5-24VDC 5-24VDC
Switching Frequency 2000Hz 2000Hz 1000Hz 500Hz
Cable IS-08-A20-03 IS-08-C20-03 IS-12-A20-03 IS-12-C20-03 IS-18-A20-03 IS-18-C20-03 IS-30-A20-03 IS-30-C20-03
Plug-in (M12 Connector) IS-08-A20-S2 IS-08-C20-S2 IS-12-A20-S2 IS-12-C20-S2 IS-18-A20-S2 IS-18-C20-S2 IS-30-A20-S2 IS-30-C20-S2
NPN NO-NC - - - - - - - -
PNP NO-NC - - - - - - - -
Relay Output: 18 to 240VAC/DC - - - - - - - -
Wiring Diagrams View of male connector M12 Configuration of Contacts
N. contacts
Available 1 2 3 4
NAMUR + _
For Sensor Cable & Accessories Note: Can only be used with AC/DC
see pages 329-332 NAMUR Relay "NSI" or instruments with
NAMUR inputs
295 DAT
» HOUSING 3 WIRE OR 4 WIRE PROGRAMMABLE OUTPUT IP67
DC Ø12 DC Ø18 DC Ø30
2mm 4mm 4mm 8mm 5mm 8mm 8mm 14mm 10mm 15mm 15mm 20mm
200mA 200mA 200mA
Present (Yellow) Present (Yellow) Present (Yellow)
1000Hz 1000Hz 300Hz
-25 to 70°C -25 to 70°C -25 to 70°C
2m 2m 2m
Nickel plated brass Nickel plated brass Nickel plated brass
*For plug type M12 change '03' to 'S2' e.g. IS-12-A3-S2
Housing Lengths (mm)
Standard Short
Connector Cable Connector Cable
SH NS SH NS SH NS SH NS
M12 68 72 58 64 48 54 42 48
M18 73 82 70 78 56 65 47 56
4 wire sensors programmable output 3 wire sensors M30 74 85 70 82 56 68 49 56
IS-12-A0-03 IS-12-E0-03 IS-12-C0-03 IS-12-F0-03 IS-18-A0-03 IS-18-E0-03 IS-18-C0-03 IS-18-F0-03 IS-30-A0-03 IS-30-E0-03 IS-30-C0-03 IS-30-F0-03
IS-12-A0-S2 IS-12-E0-S2 IS-12-C0-S2 IS-12-F0-S2 IS-18-A0-S2 IS-18-E0-S2 IS-18-C0-S2 IS-18-F0-S2 IS-30-A0-S2 IS-30-E0-S2 IS-30-C0-S2 IS-30-F0-S2
IS-12-A1-03* IS-12-G1-03* IS-12-C1-03* IS-12-H1-03* IS-18-A1-03* IS-18-G1-03* IS-18-C1-03* IS-18-H1-03* IS-30-A1-03* IS-30-G1-03* IS-30-C1-03* IS-30-H1-03*
IS-12-A2-03* IS-12-G2-03* IS-12-C2-03* IS-12-H2-03* IS-18-A2-03* IS-18-G2-03* IS-18-C2-03*IS-18-H2-03* IS-30-A2-03* IS-30-G2-03* IS-30-C2-03* IS-30-H2-03*
IS-12-A3-03* IS-12-G3-03* IS-12-C3-03* IS-12-H3-03* IS-18-A3-03* IS-18-G3-03* IS-18-C3-03* IS-18-H3-03* IS-30-A3-03* IS-30-G3-03* IS-30-C3-03* IS-30-H3-03*
IS-12-A4-03* IS-12-G4-03* IS-12-C4-03* IS-12-H4-03* IS-18-A4-03* IS-18-G4-03* IS-18-C4-03* IS-18-H4-03* IS-30-A4-03* IS-30-G4-03* IS-30-C4-03* IS-30-H4-03*
CAPACITIVE SENSORS 12-30VDC NPN OR PNP 18-240VAC/DC RELAY OUTPUT IP67
DC DC AC AC
Ø18 Ø30 Ø30 Ø18/*Ø30 Available
1-5mm 1-10mm 1-20mm 1-25mm 1-20mm 2-30mm 2-8mm *2-20mm 2-15mm *2-30mm LIMIT & PRESSURE SWITCHES & SENSORS
- -
12-30VDC (-15/+10%) 12-30VDC (-15/+10%) --
10Hz 10Hz
- - - - 18-230VAC/DC (-15/+10%) 50Hz 20-250VAC/DC (-15/+10%) 50Hz
- - - -
CS-07 CS-13 CS-09 CS-15 10Hz 25Hz (Ø18) 25Hz (Ø18)
CS-08 CS-14 CS-10 CS-16
- - - - - - N/O CCM1-1808A-A3L2 CCM2-1815A-A3L2
- - N/C CCM1-1808A-B3L2 CCM2-1815A-B3L2
Ex Class II
- - *2-20mm(Ø30) *2-30mm(Ø30)
- - N/O CCM1-3020A-A3L2 CCM2-3020A-A3L2
CS-31 *CS-31TE CS-32 *CS-32TE N/C CCM1-3020A-B3L2 CCM2-3020A-B3L2
*with 1s-5m time activating delay.
Relay Output
DAT 296
M12 DC PHOTOELECTRIC SENSOR PLASTIC AND METAL PNP/NPN IP67
Type DC M12 Ø12 Diffuse Proximity Retro-Reflective Through Beam
M12 SERIES Non-Polarized Polarized
• Nominal Voltage 10-30VDC
• Output: NPN or PNP
• Output Current: 150mA
• Housing Material: PBT (plastic v)
Nickel Plated Brass ( metal v)
• Temperature Range: -25 to 70°C
Sensing Distance 200mm 2m 1m 5.2m
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30Vdc
Emission Infrared LED 880nm Infrared LED 880nm Red light 660nm Infrared LED 880nm
Setting sensitivity trimmer sensitivity trimmer sensitivity trimmer sensitivity trimmer
Switching Frequency 1kHz 1kHz 1kHz 25Hz
Operation Mode Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^
Wiring Diagrams PNP Output Type Emitter of Thru-beam Mode
NPN Output Type
^Light/Dark changeover by the A. load or B. load ^Light/Dark changeover by the A. load or B. load
OUTPUT: Metal Housing Version Plug Type
NPN Cable Version M12P*-D0200N-CX9C4U2** M12P*-L2000N-CX9C4U2** M12P*-L1000N-CX6C4U2**-PF M12P*-T5200N-CX9C4U2**
PNP Cable Version
Emitter Cable Version M12P*-D0200P-CX9C4U2** M12P*-L2000P-CX9C4U2** M12P*-L1000P-CX6C4U2**-PF M12P*-T5200P-CX9C4U2**
Emitter M12 Plug Version
- - - M12P*-T5200D-EX9C3L2
- - - M12P*-T5200D-EX9Q4LE
*For metal type replace P with B e.g. M12B-D0200N-CX9C4U2 **For plug type replace C4U2 with Q4UE e.g. M12P-D002N-CX9Q4UE
For Sensor Cables and accessories see pages 329-332
MINI BEAM PHOTOELECTRIC SENSOR PNP AND NPN CONFIGURABLE IP67
Type DC Diffuse Proximity Retro-Reflective Through Beam
MP SERIES Medium Distance Fixed Focus
Non-Polarized Polarized
• Nominal Voltage 10-30VDC
• Output: NPN or PNP Configurable
• Output Current: 150mA
• Housing Material: Reinforced
Thermoplastic Polyester
• Temperature Range: -25 to 70°C
LIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 380mm 16mm 0.1-5m 2m 0-3m
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 880nm Infrared LED 880nm Red light 650nm Red light 650nm Infrared LED 880nm
Setting sensitivity trimmer sensitivity trimmer sensitivity trimmer sensitivity trimmer
Switching Frequency** 1kHz 1kHz 1kHz 1kHz 25Hz
Operation Mode Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON
select switch select switch select switch select switch select switch
Pico Style Pigtail Plug Type Wiring Diagrams
OUTPUT: NPN/PNP Emitter of Thru-beam Mode
NPN & PNP Cable Version
NPN & PNP M8 Pigtail Pico** MP-D0380D-CX9C4U2 MP-C0016D-CX9C4U2 MP-L5000D-CX6C4U2 MP-L2000D-CX6C4U2-PF MP-T3000*D-CX9C4U2
Emitter Cable Version
Emitter M8 Pigtail Pico** MP-D0380D-CX9P4UP MP-C0016D-CX9P4UP MP-L5000D-CX6P4UP MP-L2000D-CX6P4UP-PF MP-T3000*D-CX9P4UP
297 - - - - MP-T3000*D-EX9C3L2
- - - - MP-T3000*D-EX9P4LP
*For units with 30m sensing distance change 3000 to 030M e.g. MP-T030MD-CX9C4U2
For sensor cable and accesssories see pages 329-332. **High Speed Type available on request
SCA
AC PHOTOELECTRIC SENSORS 3 WIRE DARK/LIGHT MODE IP67
Type AC M18 Ø18 Fixed Focus Short Distance Medium Distance Retro-Reflective Through Beam Through Beam
Proximity Diffuse Proximity Diffuse Proximity Receiver Emitter
S5 SERIES
• Nominal Voltage 15-264VAC
• Output: SCR + Bidge Rectifier
• Max. Output Current: 100mA
• Temperature Range: -25 to 55°C
• Housing Material: ABS
• Switching Frequency: 25Hz
Sensing Distance 15mm 80mm 300mm 0.1-4m (R2 Reflector*) 8m 8m
AC Supply Voltage 15-264VAC
Emission 15-264VAC 15-264VAC 15-264VAC 15-264VAC 15-264VAC Infrared LED 880nm
Setting –
Output LED Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Red
Dimensions
– – Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
OUTPUT:
Dark Mode. Cable Version Red Red Red Red Red
Light Mode. Cable Version AC AXIAL VERSION
Wiring Diagrams
23.5 Models S5
For sensor cable and Output LED With trimmer Without Trimmer
accessories see pages 329-332 Power on LED
22 3.2 X1 52 42
L 75 65
LIMIT & PRESSURE SWITCHES & SENSORS
S5-1-D15-10 S5-1-C8-10 S5-1-C30-10 S5-1-A2-10 S5-1-F8-10 S5-1-G8-00
S5-1-D15-20 S5-1-C8-20 S5-1-C30-20 S5-1-A2-20 S5-1-F8-20
Light = NO. Dark = NC Receiver
For Radial Optics 90° Sensing use DEV90 Accessory
Emitter
S5 SERIES AXIAL 10-30VDC 4 WIRE CONFIGURABLE DARK/LIGHT MODE IP67
Type DC M18 Ø18 Diffuse Proximity Retro-Reflective Through Beam
S5 SERIES
Short Medium Long Fixed Focus Non- Polarized Receiver Emitter
• Nominal Voltage 10-30VDC Distance
• Output: NPN or PNP Configurable Distance Distance Polarized
• Max. Output Current: ≤150mA
• Temp. Range: -25 to 55°C
• Housing Material: ABS
Sensing Distance 100mm 350mm 600mm 15mm 4m(R2 Reflector)* 3m(R2 Reflector)* 12m 12m
Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Red LED 880nm
Setting Sensitivity – – Sensitivity Sensitivity – – Sensitivity
trimmer trimmer trimmer trimmer
Output LED Red OUTPUT Red OUTPUT Red OUTPUT Red OUTPUT Red Power
Green STABILITY Green STABILITY Green STABILITY Green STABILITY
Switching Frequency 500Hz 500Hz 500Hz 250Hz
Dimensions
For sensor cable and
accessories see pages 329-332.
For Radial Optics 90° Sensing use
DEV90 Accessory
OUTPUT:
NPN & PNP Dark/Light.Cable Version S5-5-C10-30 S5-5-C35-30 S5-5-C60-30 S5-5-D15-30 S5-5-A4-30 S5-5-B3-30 S5-5-F12-30 S5-5-G12-00
S5-5-C60-32 S5-5-D15-32 S5-5-A4-32 S5-5-B3-32 S5-5-F12-32 S5-5-G12-02
NPN & PNP Dark/Light. M12 plug* S5-5-C10-32 S5-5-C35-32
Plug Type Wiring Diagrams
DAT 298
DC PHOTOELECTRIC SENSORS SHORT HOUSING PLASTIC »
Type DC M18 Ø18 Diffuse Proximity Medium Distance Long Distance Fixed Focus
Short Distance
S15 SERIES
• Nominal Voltage 12-30VDC
• Output: NPN or PNP
• Output Current: ≤100mA
• Temperature Range: -25 to 55°C
• New stainless steel models
• IP67+IP69K on all models
• Johnson Diversey certification for
detergents
• Atex II 3dg certification
Sensing Distance 1-10cm 1-35cm 1-100cm 1-5cm
DC Supply Voltage 12-30VDC 12-30VDC
Emission 12-30VDC 12-30VDC Infrared LED 880nm Red LED 660nm
Setting Sensitivity Trimmer* -
Output LED Infrared LED 880nm Infrared LED 880nm Yellow Output LED Yellow Output LED
Switching Frequency 500 Hz 1Khz
Operation Mode – Sensitivity Trimmer* Light/Dark Selectable^ Light/Dark Selectable^
S15-PA-2/3
Yellow Output LED Yellow Output LED S15-PA/NA-5
500 Hz 500 Hz
Light/Dark Selectable^ Light/Dark Selectable^
Dimensions S15-PA-2/3-D50
A01/B01/C31/ M01
T01/F01/G01
OUTPUT: L 48.8 53.3
NPN Cable
PNP Cable L1 32.85 37.55
NPN M12 Plug
PNP M12 Plug S15-PA-2-C00-NK S15-PA-2-C10-NK - S15-PA-2-D50-NK
NPN M12 Plug Stainless Steel
PNP M12 Plug Stainless Steel S15-PA-2-C00-PK S15-PA-2-C10-PK - S15-PA-2-D50-PK
– S15-PA-5-C11-NK S15-PA-5-C31-NK -
– S15-PA-5-C11-PK S15-PA-5-C31-PK -
– S15-NA-5-C11-NK S15-NA-5-C31-NK -
– S15-NA-5-C11-PK S15-NA-5-C31-PK -
*Sensitivity trimmer on M12 Plug Units Only For sensor cable and accessories see pages 329-332
DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN NO-NC IP67
Type DC M18 Ø18 Diffuse Proximity
S50 SERIES Short Distance Medium Distance Long Distance Fixed Focus
• Nominal Voltage 10-30VDC 400mm
• Output: NPN or PNP 10-30VDC
• Contacts: NO and NC Infrared LED 880nm
• Output Current: ≤100mA –
• Housing Material: PBT - Lens PMMA Sensitivity trimmer
• Temperature Range: -25 to 55°C Yellow/Green (stability)
''One For All" 1kHz
• Flat plastic or cylindrical metal housing Dark on NO / light on NC
• Versions with Trimmers
• Cable or M12 Connection
• EN standard NPN or PNP NO-NC
configuration
Sensing Distance 100mm 700mm 100mm
10-30VDC 10-30VDC
DC Supply Voltage 10-30VDC Infrared LED 880nm Red LED 630nm
– –
LIMIT & PRESSURE SWITCHES & SENSORS Emission Red 630nm Sensitivity trimmer –
Yellow/Green (stability) Yellow
Minimum Detectable Object – 1kHz 1kHz
Dark on NO / Light on NC Dark on NO / light on NC
Setting –
M12 Connector
Output LED Yellow
Switching Frequency 1kHz
Operation Mode Dark on NO / Light on NC
Metal Housing Version Wiring Diagrams
Plug Type
OUTPUT:
NPN NO-NC Cable S50-P**A-2*-C10-NN S50-P**A-2*-C21-NN S50-P**A-2*-C01-NN S50-P**A-2*-D00-NN
PNP NO-NC Cable S50-P**A-2*-C10-PP S50-P**A-2*-C21-PP S50-P**A-2*-C01-PP S50-P**A-2*-D00-PP
Emitter Cable – – ––
*For plug type replace 2 with 5 e.g. S50-PA-5-B01-NN For sensor cable and accessories see pages 329-332
**For metal type replace P with M e.g. S50-MA-5-C10-PK For Radial Optics 90° Sensing use DEV90 Accessory
299 DAT
»AND STAINLESS STEEL PNP/NPN IP67 & IP69K ATEX II 3dg
Retro-Reflective Polarized Transparents Through Beam Emitter
Non-Polarized Background Suppression Receiver
0.1-5m (R2 Reflector) 0.1-4m (R2 Reflector) 0.1-8m (R2 Reflector) 40-120mm 0-20m 0-20m
12-30VDC 12-30VDC 12-30VDC 12-30VDC 12-30VDC 12-30VDC
Infrared LED 880nm Red LED 660nm Red LED 660nm Red LED 660nm - Infrared LED 880nm
Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* -
Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED
500 Hz 500 Hz 500 Hz 500 Hz 250 Hz -
Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^
Wiring Diagrams M12 Connector ^With Light/Dark input not connected
Cable S15...A01/B01/C11/C31/T01/F01/M01 S15...G01 the Proximity models function in the
S15...A00/B00/C00/C10/F00/D50 S15...G00 light mode, the retroreflex and
through beam models in the Dark
mode. The Light mode can be
selected connecting the Light/Dark
input to +Vdc and the Dark mode
connecting it to the 0Vdc.
S15-PA-2-A00-NK S15-PA-2-B00-NK - - S15-PA-2-F00-NK S15-PA-2-G00-XG
S15-PA-2-A00-PK S15-PA-2-B00-PK - - S15-PA-2-F00-PK
S15-PA-5-A01-NK S15-PA-5-B01-NK S15-PA-5-T01-NK S15-PA-5-M01-NK S15-PA-5-F01-NK S15-PA-5-G01-XG
S15-PA-5-A01-PK S15-PA-5-B01-PK S15-PA-5-T01-PK S15-PA-5-M01-PK S15-PA-5-F01-PK
S15-NA-5-A01-NK S15-NA-5-B01-NK S15-NA-5-T01-NK - S15-NA-5-F01-NK S15-NA-5-G01-XG
S15-NA-5-A01-PK S15-NA-5-B01-PK S15-NA-5-T01-PK - S15-NA-5-F01-PK
*Sensitivity trimmer on M12 Plug Units Only For sensor cable and accessories see pages 329-332
DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN NO-NC IP67
Retro-Reflective Contrast Sensor Through Beam
Non-Polarized Retroreflex for Transparents
Polarized
0.1-5m (R2,R5 reflector*) 4m (R2,R5 reflector*) 0.7-1.7m (R2,R5 reflector*) 10mm 0-20m LIMIT & PRESSURE SWITCHES & SENSORS
10-30VDC 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Infrared LED 880nm Red 660nm Red LED 660nm White LED 400-700nm Infrared LED 880nm
– – – 0.5mm –
– Sensitivity trimmer Sensitivity trimmer Teach-in push-button Sensitivity trimmer
Yellow Yellow/Green (stability) Yellow Yellow/Green/Red Error Yellow/Green (stability)
1kHz 1kHz 1kHz 5kHz 250kHz
Dark on NO / light on NC Dark on NO / light on NC Dark on NO / light on NC Dark with EASYtouch™ Dark on NO / light on NC
S50-P**A-2*-A00-NN S50-P**A-2*-B01-NN S50-P**A-2*-T01-NN S50-P**A-2*-W03-NN S50-P**A-2*-F01-NN
S50-P**A-2*-T01-PP S50-P**A-2*-W03-PP S50-P**A-2*-F01-PP
S50-P**A-2*-A00-PP S50-P**A-2*-B01-PP – – S50-P**A-2*-G00-XG
–– DAT 300
Laser models available on request
DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN IP67
Type DC M18 Ø18 Diffuse Proximity Retro-Reflective Through Beam
Non-Polarized Polarized
S51 SERIES Short Distance Long Distance Receiver Emitter
• Nominal Voltage 10-30VDC
• Output: NO, NPN or PNP
• Output Current: ≤100mA
• Housing Material: PBT (plastic v) Nickel
Plated Brass (metal v)
• Temperature Range: -25 to 55°C
• Flat plastic or cylindrical metal housing
• Cable or M12 connection NPN or PNP
output
•Standard 3 wire connection configuration
Sensing Distance 100mm 400mm 0.1-4m (R5 Reflector) 0.1-3m (R5 Reflector) 20m
DC Supply Voltage
Emission 10-30VDC 10-30VDC 10-30VDC
Setting
Output LED Infrared LED 880nm Infrared LED 880nm Red LED 650nm Infrared LED 880nm
Switching Frequency
Operation Mode – Sensitivity trimmer – Sensitivity trimmer –
–– – Yellow Output LED
500Hz 500Hz 120Hz –
Dark/Light selectable^ Dark/Light selectable^ Dark/Light selectable^
^With Light/Dark input not connected the Proximity models function in the light mode, the retroreflex and through beam models in the
Dark mode. The Light mode can be selected connecting the Light/Dark input to +Vdc and the Dark mode connecting it to the 0Vdc
Metal Housing Version Wiring Diagrams M12 Connector
OUTPUT: Plug Type
NPN Cable
PNP Cable S51-P**A-2*-C10-NK S51-P**A-2*-C01-NK S51-P**A-2*-A00-NK S51-P**A-2*-B01-NK S51-P**A-2*-F00-NK S51-P**A-2*-G00-XG
S51-P**A-2*-C10-PK S51-P**A-2*-C01-PK S51-P**A-2*-A00-PK S51-P**A-2*-B01-PK S51-P**A-2*-F00-PK
*For plug type replace 2 with 5 e.g. S51-PA-5-B01-PK For sensor cable and accessories see pages 329-332
**For metal type replace P with M e.g. S51-MA-5-B01-PK For Radical Optics, replace A with R. E.g. S51-PR-5-B01-PK
MINIATURE PHOTOELECTRIC SENSOR BASIC LINE NPN or PNP NO-NC IP66
Type DC Diffuse Proximity Retro-Reflective Through Beam Through Beam
S41 SERIES Emitter Receiver
Polarized Transparents
• Nominal Voltage 10-30VDC
• Output: NPN or PNP NO-NC
• Output Current: 100mA max.
• Housing Material: PMMA Plastic
• Temperature Range: -25 to 55°C
• Models with trimmer setting
• NPN or PNP output
•Double NO-NC
Sensing Distance 0.2-350mm 0.1-2.5m (R2 Reflector) 0.1-0.7m (R2 Reflector) 0.1-6m 0.1-6m
Supply Voltage 10-30VDC 10-30VDC
LIMIT & PRESSURE SWITCHES & SENSORS Emission Infrared LED 880nm 10-30VDC 10-30VDC 10-30VDC Infrared LED 880nm
Setting Sensitivity trimmer –
Output LED Red/Green Red LED 660nm Red LED 660nm Infrared LED 880nm Red/Green
Switching Frequency 500Hz 500Hz
Operation Mode Dark or Light Sensitivity trimmer Sensitivity trimmer – Dark or Light
Wiring Diagrams
32H x 12W x 20D Yellow/Green Red/Green Red/Green
500Hz 500Hz 500Hz
Dark or Light Dark or Light Dark or Light
Plug Type M8 CONNECTOR M8 CONNECTOR M8 CONNECTOR
OUTPUT: S41-2*-C-P S41-2*-B-P S41-2*-T-P S41-2*-G S41-2*-F-P
PNP NO-NC Cable
NPN NO-NC Cable S41-2*-C-N S41-2*-B-N S41-2-*T-N S41-2*-G S41-2*-F-N
301 *For plug type replace 2 with 5 e.g. S41-5-C-P For sensor cable and accessories see pages 329-332
*For plug and cable use part number CS-B1-02-G-05/03
DAT
PHOTOELECTRIC SENSORS MICROPROCESSOR-BASED TEACH-IN NPN/PNP IP67
Type DC Diffuse Polarized Retro-Reflective Background
Proximity Transparents Suppression
S40 SERIES
• Nominal Voltage 10-30VDC
• Output: NPN or PNP
• Output Current: 100mA max.
• Housing Material: ABS
• Temperature Range: -20 to 60°C
• EASYtouch™ microprocessor teach in
and Remote setting
• Cable or M8 connection
• NPN or PNP
Sensing Distance 0.5-300mm 0.1-2.5m (R2 Reflector) 0.1-7m (R2 Reflector) 15-100mm
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC
Emission Red LED 660nm Red LED 660nm Red LED 660nm
Setting Teach-in button Teach-in push-button Teach-in button
Output LED Yellow/Green Yellow/Green Yellow/Green
Switching Frequency 4kHz 1kHz 1kHz
Operation Mode Dark/light prog. Dark/light programmable Dark/light prog.
M8 Connector Wiring Diagrams
NPN output PNP output S40-x-G
Plug Type
OUTPUT: S40-PR-2*-C03-PH S40-PR-2*-B03-PH S40-PR-2*-T03-PH S40-PR-2*-M03-PH
PNP Cable
NPN Cable S40-PR-2*-C03-NH S40-PR-2*-B03-NH S40-PR-2*-T03-NH S40-PR-2*-M03-NH
*For plug type replace 2 with 5 e.g. S40-PR-5-A03-PH For sensor cable and accessories see pages 329-332
*For plug and cable use part number CS-B1-02-G-05/03 Laser models available on request
DC MINIATURE PHOTOELECTRIC SENSORS NPN/PNP DARK/LIGHT MODE IP67
Type DC Diffuse Proximity Polarized Narrow Beam Proximity Through Beam Set
Retro-Reflective
S3Z SERIES Ø 1mm
• Nominal Voltage 10-30VDC
• Output: NPN or PNP
• Output Current: ≤100mA
• Housing Material: PC/PBT
• Temperature Range: -25 to 55°C
Sensing Distance 0-700mm 0.05-4m (R5 Reflector)* 150mm 15m LIMIT & PRESSURE SWITCHES & SENSORS
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 870nm Red LED 665nm Red LED 665nm Infrared LED 870nm
Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
Output LED Yellow/Green (stability) Yellow/Green (stability) Yellow/Green (stability) –
Switching Frequency 500Hz 500Hz 500Hz 500Hz
Operation Mode Dark or light Dark or light Dark or light Dark or light
Wiring Diagrams
M8 Connector
OUTPUT: S3Z-PR-2*-C11-PL S3Z-PR-2*-B01-PL S3Z-PR-2*-C01-PL S3Z-PR-2*-FG01-PL
PNP Light. Cable Version
PNP Dark. Cable Version S3Z-PR-2*-C11-PD S3Z-PR-2*-B01-PD S3Z-PR-2*-C01-PD S3Z-PR-2*-FG01-PD
NPN Light. Cable Version
NPN Dark. Cable Version S3Z-PR-2*-C11-NL S3Z-PR-2*-B01-NL S3Z-PR-2*-C01-NL S3Z-PR-2*-FG01-NL
Light = NO. Dark = N.C
S3Z-PR-2*-C11-ND S3Z-PR-2*-B01-ND S3Z-PR-2*-C01-ND S3Z-PR-2*-FG01-ND
*For plug type replace 2 with 5 e.g. S3Z-PR-5-C01-PL For sensor cable and accessories see pages 329-332
*For plug and cable use part number CS-B1-02-G-05/03 Laser models available on request
DAT 302
ECONOMY DC MINIATURE SENSOR PNP/NPN IP67
Type DC Diffuse Proximity Long Distance Fixed Focus
S100 SERIES Medium Distance
• Nominal Voltage: 10-30VDC
• Output: NPN or PNP
• Output Current: 100mA
• Temperature Range: -25 to 55°C
• Housing Material: ABS (housing) /
PMMA (indicators cover)
• Cost Effective
Sensing Distance 300mm 500mm 70mm
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC
Emission Red LED 632nm Red LED 632nm Red LED 632nm
Switching Frequency 500 Hz 500 Hz 500 Hz
Operation Mode Dark/Light input Dark/Light input Dark/Light input
Plug Type Dimensions
Anti tampering sensor
Two threaded
front mounting
holes
OUTPUT: Two slotted rear
mounting holes
PNP Cable S100-PR-2*-C00-PK S100-PR-2*-C10-PK S100-PR-2*-D00-PK
NPN Cable S100-PR-2*-C00-NK S100-PR-2*-C10-NK S100-PR-2*-D00-NK
Type DC *For plug type replace 2 with 5 e.g. S50-PA-5-B01-NN Through Beam
S100 SERIES For sensor cable and accessories see pages 329-332
• Nominal Voltage: 10-30VDC Retro-Reflective Background
• Output: NPN or PNP Suppression
• Output Current: 100mA Non-Polarized Polarized
• Temperature Range: -25 to 55°C
• Housing Material: ABS (housing) /
PMMA (indicators cover)
• Cost Affective
LIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 8m 6m 30-100mm 12m
DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Infrared LED 860nm Red LED 632nm Red LED 632nm Infrared LED 860nm
Switching Frequency 500 Hz 500 Hz 500 Hz 250Hz
Operation Mode Dark/Light input Dark/Light input External Teach-In Dark/Light input
Wiring Diagrams
For plug and cable, use code CS-BI-02-G-05/3
PNP Cable S100-PR-2*-A00-PK S100-PR-2*-B10-PK S100-PR-2*-M00-PH S100-PR-2*-FG00-PK
S100-PR-2*-B10-NK S100-PR-2*-M00-NH S100-PR-2*-FG00-NK
NPN Cable S100-PR-2*-A00-NK
DAT
303
DC ADVANCED PHOTOELECTRIC SENSORS NPN/PNP IP67 ATEX
Type DC Diffuse Proximity Retro-Reflective Through Beam
S8 SERIES Polarized
Transparents
• Nominal Voltage 12-30VDC 500mm 5m (R2 Reflector) 50-800mm** 25m
• Output: NPN or PNP NO 12-30VDC
• Output Current: ≤100mA max. Red LED 660nm 12-30VDC 12-30VDC
• Housing Material: ABS Mono turn sensitivity adj. trimmer
• Temperature Range: -10 to 55°C Yellow/Green Red LED 660nm Red LED 660nm
• Excellent performances within 500us
small dimensions (14x42x25mm) 1kHz Mono turn sensitivity adj. trimmer Set push button (T53) Mono turn sensitivity adj. trimmer
• Compact Dimensions Dark/Light selectable
• Very High Resolution Yellow/Green Yellow/Green
• High performance for most M8 Connector
challenging applications 500us 250us 500us
Sensing Distance 1kHz 2kHz 1kHz
DC Supply Voltage Dark/Light selectable Dark/Light selectable
Emission M8 Connector - B01/T51 Version - T53 Version M8 Connector
- F01 Version
Setting
Output LED
Response Time
Switching Frequency
Operation Mode
Wiring Diagrams
- G00 Version
OUTPUT: S8-PR-5-C01-PP S8-PR-5-B01-PP S8-PR-5-T51**-PP S8-PR-5-F01-PP
PNP M8 Plug*
NPN M8 Plug* S8-PR-5-C01-NN S8-PR-5-B01-NN S8-PR-5-T51**-NN S8-PR-5-F01-NN
Through Beam Emitter
- - - S8-PR-5-G00-XG
*For M8 plug and cable see pages 329-332. Stainless Steel models available on request
**For retro-reflective for transparent units with 2000mm sensing distance replace 1 with 3 e.g. S8-PR-5-T53-PP
*For plug and cable use part number CS-B1-02-G-05/03
Type DC Clear and Shiny Detection Background Suppression Contrast
S8 SERIES
• Nominal Voltage 12-30VDC
• Excellent performances within
small dimensions
• Compact Dimensions
• Very High Resolution
Sensing Distance 100-300mm 50-150mm 50-300mm 20-200mm 9mm
DC Supply Voltage 12-30VDC
Emission 12-30VDC 12-30VDC Blue, Green, Red
Setting Teach-in push-button
Output LED Red LED 660nm Red Laser Red LED 660nm Red Laser Yellow/Green LIMIT & PRESSURE SWITCHES & SENSORS
Response Time 50us
Switching Frequency 8-turn distance adj. trimmer, Teach 8-turn distance adj. trimmer 10kHz
Operation Mode Dark/Light selectable
Wiring Diagrams Yellow/Green Yellow/Green
OUTPUT: 1ms 1ms 100us
PNP M8 Plug*
NPN M8 Plug* 500Hz 500Hz 5kHz
Remote Dark/Light selectable Dark/Light selectable
M8 Connector M8 Connector -
PR Version
S8-PR-5-M53-PP S8-PH-5-M53-PP S8-PR-5-M01-PP M8 Connector -
- - S8-PR-5-M01-NN PH Version
*For M8 plug and cable see pages 329-332
S8-PH-5-M01-PP S8-PR-5-W03-PP
S8-PH-5-M01-NN S8-PR-5-W03-NN
All the safety electrical and mechanical regulations and laws have to be respected during sensor functioning. The sensor has to be protected
against mechanical damages. Place the given labels in a visible position close to the laser emission. • Do not look directly into the laser beam! •
Do not point the laser beam towards people! • These sensors are not to be used for safety applications!
DAT 304
THE MOST COMPLETE UNIVERSAL SENSOR IN A COMPACT 50X50MM HOUSING IP67
Type DC Diffuse Proximity Retro-Reflective Through Beam
S62 SERIES C01 C11
Non-Polarised Polarised Receiver Emitter
• New better modern look
50x50 housing
• Better performance
• Retroreflective up to 13m
• VDC and VAC Models
Sensing Distance 0-900mm 0-200cm 0.1-13m (R2,R5 reflector) 0.1-8m (R2,R5 reflector) 0-25m 0-25m
Supply Voltage
Emission 10-30VDC / 24-240VAC/24-60VDC**
Setting
Output LED RED 640nm Red 640nm
Output
Mono-turn sensitivity adjustment trimmer. Mono-turn light/dark trimmer (S62-RX/PN)
Output Current
Saturation Voltage OUTPUT LED (yellow) / STABILITY LED (green) POWER ON LED (green)
Response Time
Switching Frequency NPN/PNP (S62-PN)dc vers. NPN or PNP NO/NC Test + Test -
Mechanical Protection (S62-PP/NN)dc vers. Relay SPDT 250VAC/30VDC (S62-RX)
Housing Material
Operating Temperature S62-PA-2/5, S62-M version: ≤100mA (overload and overvoltage protection), S62-PA-1-RX version: 2A Max (resist load)
Dimensions ≤2v S62-PA-2/5 VDC vers
500us max, 25ms (Relay version) 500us max, 25ms (Relay version) 1ms, 25ms (Relay version)
1kHz, 20Hz (Relay version) 2kHz, 20Hz (Relay version) 50kHz, 20Hz
IP67 IP67 IP67
ABS ABS ABS
-10 to 55C° -10 to 55C° -10 to 55C°
OUTPUT: S62-PA-2*-C01-NN S62-PA-2*-C11-NN - S62-PA-5-B01-NN S62-PA-2*-F01-NN
NPN NO-NC Cable
PNP NO-NC Cable S62-PA-2*-C01-PP S62-PA-2*-C11-PP - S62-PA-2*-B01-PP S62-PA-2*-F01-PP S62-PA-2*-G00-XG
NPN/PNP Cable
Relay Cable** S62-PA-2*-C01-PN S62-PA-2*-C11-PN S62-PA-2*-A01-PN S62-PA-2*-B01-PN S62-PA-2*-F01-PN
S62-PA-1-C01-RX S62-PA-1-C11-RX S62-PA-1-A01-RX S62-PA-1-B01-RX S62-PA-1-F01-RX S62-PA-1-G00-XX
Wiring Diagrams
LIMIT & PRESSURE SWITCHES & SENSORS *For plug type replace 2 wih 5 e.g. S62-PA-5-C01-NN Laser models available on request
For sensor cable and accessories see pages 329-332
DC Models AC Models**
S62-PA-2/5-PN S62-PA-1-A/B/C/F S62-PA-1-G
S62-PA-2/5-PP/NN S62-PA-2/5-G S62-PA-5...PP/NN (M12 connector)
305 DAT
BACKGROUND SUPPRESSION 50X50 COMPACT PNP/NPN IP67
Type DC Background Suppression
S62 SERIES
• Nominal Voltage 10-30VDC
• Units with time adjustment
trimmer
• Background suppression
from 3cm-2m
Sensing Distance 30-300mm 60-600mm 60-1200mm 200-2000mm
DC Supply Voltage
Emission 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Setting
Output LED RED 660nm Infrared (880nm)
Output
Output Current Muliti Turn distance adjustment trimmer / Timer adjustment trimmer (S62-M05/M15/M25/M35). Dark/light selection mono turn trimmer (S62-M01/M11-PN)
Saturation Voltage
Response Time OUTPUT LED (yellow) / STABILITY LED (green) (S62-M0/M1) POWER ON LED (green) (S62-M2/M3)
Switching Frequency
Mechanical Protection NPN or PNP NO/NC (S62-PP/NN)
Housing Material
Operating Temperature 100mA (overload and voltage protection)
Dimensions ≤2v ≤2v ≤2v ≤2v
500us (S62-M0/M1), 1ms (S62-M2) 1,5ms(S62-M3)
1kHz (S62-M0/M1), 500Hz (S62-M2), 330Hz (S62-M3)
IP67 IP67 IP67 IP67
ABS ABS ABS ABS
-10 to 55C° -10 to 55C° -10 to 55C° -10 to 55C°
OUTPUT: S62-PA-2-M01-PP S62-PA-2-M11-PP S62-PA-2-M21-PP S62-PA-2-M31-PP
PNP NO-NC Cable
NPN NO-NC M12 Plug S62-PA-5-M01*-NN S62-PA-5-M11*-NN S62-PA-5-M21*-NN S62-PA-5-M31*-NN
PNP NO-NC M12 Plug
S62-PA-5-M01*-PP S62-PA-5-M11*-PP S62-PA-5-M21*-PP S62-PA-5-M31*-PP
Wiring Diagrams
* For units with timer adjustment trimmer change 1 to 5 e.g. S62-PA-5-M01-NN to S62-PA-5-M05-NN
For sensor cable and accessories see pages 329-332 Laser models available on request
S62-PA-2/5...PN S62-PA-2...PP/PN S62-PA-5...PP/PN (M12 connector)
Detection Diagrams LIMIT & PRESSURE SWITCHES & SENSORS
DAT 306
MAXI SENSOR FOR CRITICAL APPLICATIONS VAC/VDC IP67
Type AC/DC Diffuse Proximity Polarized Background Through Beam
S300-PR SERIES Retro-Reflective Suppresion Receiver Emitter
• Excellent Optical Performances
• Heavy duty industrial plastic housing
• Distance trimmer clutch for mechanical
background suppression models
• Units with defogging functions
Sensing Distance 5m 22m 2.5m 60m
Supply Voltage
Emission 24-240VAC / 12-240VDC
Setting
Infrared LED 940nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm
Output LED Mono-turn Mono-turn Multi-turn Mono-turn Sensitivity Trimmer
Output Sensitivity Trimmer Sensitivity Trimmer Adjustment Screw
Output current
Saturation Voltage Output LED (Yellow) Stability LED (GREEN) Output Yellow/ Power On LED Green
Response Time Stability Green
Switching Frequency
Mechanical Protection NPN & PNP open collector. Relay SPDT electromagnetic relay 250VAC, 30VDC*
Housing Material 100mA (Resistive Load). 3A (Resistive Load)*
Connections <2.4V Max NPN & PNP only
Operating Temperature
20ms (AC), 1ms (S300-C, S300-B, S300-F/G) (DC) 2ms (S300-M) (DC)
25Hz (AC), 500Hz (S300-B, S300-C, S300-F/G) (DC), 250Hz (S300-M) (DC)
IP67
PBT (30% Fibre-reinforced Glass)
Terminal Block (Recommended Cable Diameter 8mm – 10mm) (AC), 4-Pin M12 Plug (DC)
-40º to 55ºC
Dimensions M12 Connector Version
OUTPUT:
Relay NO/NC ADJ, No Timer S300-PR-1-C01-RX S300-PR-1-B01-RX S300-PR-1-M01-RX S300-PR-1-F01-RX S300-PR-1-G00-EX***†
Relay NO/NC ADJ, Timer S300-PR-1-C06-RX*** S300-PR-1-B06-RX*** S300-PR-1-M06-RX*** S300-PR-1-F06-RX***
NPN & PNP M12 Plug ADJ, No Timer S300-PR-5-C01-OC S300-PR-5-B01-OC S300-PR-5-M01-OC S300-PR-5-F01-OC
NPN & PNP M12 Plug ADJ, Timer S300-PR-5-C06-OC S300-PR-5-B06-OC S300-PR-5-G00-EX***†
S300-PR-5-M06-OC S300-PR-5-F06-OC
*24-240VAC/12-240VDC AC voltage untis only. ***For defogging functions, add -M to part number. †No ADJ, No Timer, No Outputs
For sensor cable and accessories see pages 329-332
LIMIT & PRESSURE SWITCHES & SENSORS Wiring Diagrams M12 Connector (only DC models)
Connections G
Connections B, C, M , F
M12 Connector (only DC models)
Timing Functions Indicators
Four selectable timing functions: one shot, ON DAT
delay, OFF delay, ON/OFF delay and normal
mode. Trimmer adjustment of the functions is
available. The timing functions can be
particularly useful in applications where the
output signal pulse has to be modified.
307
ADVANCED COST EFFECTIVE MAXI SENSORS VAC/VDC IP67
Type AC/DC Diffuse Proximity Retro-Reflective Background Through Beam
S300-PA SERIES Non-Polarized Polarized Suppresion Receiver Emitter
• Excellent cost/performance ratio
• Terminal block for both VDC and
VAC/VDC free voltage versions
• Sturdy industrial plastic housing IP67
Sensing Distance 5-200cm 01.-15m 0.1-10m 20-200cm 0-50m
Supply Voltage
Emission 12-30VDC or 24-240VAC / 12-60VDC Infrared LED 880nm
Setting Infrared LED 940nm Infrared LED 880nm Red LED 660nm Infrared LED 880nm
Output LED 7-Turns adjustment screw. Mono-turn Sensitivity Trimmer
Output
Output Current Mono-turn Sensitivity Trimmer. Dark/Light Dip Switch mode On Dark/Light Dip Switch. Dip Dark/Light Dip Switch.
Saturation Voltage delay/Off delay/Single pulse (One-Shot)(S300-X06 version only)
Response Time Switch mode On delay/Off Dip Switch mode On
Switching Frequency delay/Off delay/On-Off
Mechanical Protection delay/On-Off delay/Single delay/Single pulse
Housing Material pulse (One-Shot (One-Shot)(S300-X06
Connections
Operating Temperature (S300-X06 version only) version only)
Dimensions
OUTPUT LED (Yellow) / STABILITY LED (Green) / POWER ON LED (Green)(S300-G version)
NPN & PNP open collector. Relay SPDT electromagnetic relay 250VAC, 30 VDC*
100mA (resistive load). 3A (resistive load)*
<2.4V Max NPN & PNP only
1ms (DC) 25ms (AC) 2ms (S300-G version)
500Hz (DC) 20Hz (AC) 250Hz (S300-G version)
IP67
PBT 30% fibre-reinforced glass
Terminal Block (recommended cable diameter 8-10mm)
-20 to 55°C
100,4 96
OUTPUT: 27 40 50 5589.7S300-PA-1-B01-RX S300-PA-1-M01-RX S300-PA-1-F01-RX S300-PA-1-G00-EX**
Relay NO/NC ADJ, No Timer 67.5 S300-PA-1-B06-RX S300-PA-1-M06-RX S300-PA-1-F06-RX
Relay NO/NC ADJ, Timer S300-PA-1-C01-RX S300-PA-1-A01-RX
NPN & PNP ADJ, No Timer S300-PA-1-C06-RX S300-PA-1-A06-RX LIMIT & PRESSURE SWITCHES & SENSORS
NPN & PNP ADJ, Timer
S300-PA-2-C01-OC S300-PA-2-A01-OC S300-PA-2-B01-OC S300-PA-2-M01-OC S300-PA-2-F01-OC
Wiring Diagrams S300-PA-2-C06-OC S300-PA-2-A06-OC S300-PA-2-B06-OC S300-PA-2-M06-OC S300-PA-2-F06-OC S300-PA-2-G00-EX**
*24-240VAC/24-60VDC AC voltage untis only.
**No ADJ, No Timer, No Outputs.
Connections G Connections A, B, C, M, F Timing Functions
AC Modles DC Modles AC Modles DC Modles Five selectable timing functions: one shot, ON delay, OFF
delay, ON/OFF delay and normal mode. Trimmer adjustment
of the functions is available.The timing functions can be
particularly useful in applications where the output signal
pulse has to be modified.
DAT 308
COMPLETE RANGE OF CONTRAST, REGISTRATION MARK,»
Type DC TLU Series TL46 Series
Trimmer Basic
• Nominal Voltage 10-30VDC
• World leading mark sensors
• Red/green or white LED
emission
• Rotatable connector
Sensing Distance 6-12mm 6-12mm 6-12mm
DC Supply Voltage
Setting 10-30VDC 10-30VDC 10-30VDC
Output LED Teach-in with 2 Pushbuttons / Remote Multi Turn Digital Trimmer for an easy and
Automatic
Emission
Spot quick adjustment of the switching threshold
Spot Dimension
Output Red Output / Green Ready Yellow Output / Green Ready / Orange Yellow Output / Green Ready
Analogue Output Indicator Arrows
Output Current
Saturation Voltage Red / Green LED White 400-700nm RGB LED
Response Time
Switching Frequency Vertical Horizontal Vertical Vertical Horizontal
Operation Mode
Mechanical Protection 1.5 x 5mm 1.5 X 5mm 1.5 X 5mm
Housing Material
Operating Temperature NPN and PNP NPN and PNP Programmable NPN or PNP Programmable
Connections
Dimensions Yes 0-5VDC 0.5-5.5VDC on white target 0.5-5.5VDC on white target
200mA Max <100mA Max <100mA Max
1V max (NPN Version) 2V Max (PNP Version) < 2V < 2V
50us 25us 33us
10KHz 20KHz 15KHz
Automatic Dark/Light Selection Dark/Light with switch Dark/Light selectable
IP67 IP67 IP67
ZAMA Aluminium Aluminium
-10o to 55oC -10o to 55oC -10o to 55oC
3m 6.1mm Shielded Cable *M12 4-Pole connector *M12 5-Pole Connector *M12 5-Pole Connector
M5
M5
OUTPUT:
NPN & PNP (Programmable) - - - TL46-W-815 TL46-W-815L
- -
NPN Cable TLU-011** TLU-011**L TL46-A-425 - -
- -
LIMIT & PRESSURE SWITCHES & SENSORS PNP Cable TLU-111** TLU-111**L TL46-A-415 - -
NPN-NO RS485 - - -
PNP-NO RS485 - - -
**For plug type replace 1 with 5 e.g. TLU-115
For sensor cable and accessories see pages 329-332
Wiring Diagrams Trimmer Verion
309 Basic Standard
and Enhanced
Versions
** For plug and cable
use part number
CS-A1-03-G-03
DAT
TL46 Series »COLOUR AND LUMINESCENCE SENSORS IP67
Standard
Luminescence LD46 Series Colour S65-V Series
Enhanced
RGB
6-12mm 6-12mm 10-20mm 5-45mm
10-30VDC 10-30VDC 15-30VDC 10-30VDC
Automatic / Manual / Remote Automatic / Manual / Remote / Dynamic Manual using +, - and SET push buttons SET & SEL push buttons
Yellow Output / Green Ready / Orange Delay/ Yellow Output / Green Ready / Orange Delay/ Yellow Output / Green Ready / Orange Delay/ 4 Digit Display Green active Outputs, yellow
Orange Keylock / 5 Segment Bargraph Orange Keylock / 4 Digit Display Orange Keylock / 5 Segment Bargraph or function output
RGB LED RGB LED LED UV, 375nm White LED 400-700nm
Vertical Horizontal Vertical Horizontal
1.5 X 5mm 1.5 X 5mm 2 x 8mm at 10mm 4mm at 20mm
NPN or PNP Programmable NPN or PNP Programmable 1 x NPN 1 x PNP 3 x PNP or NPN
Yes 0-5VDC Yes 0-5VDC
<100mA Max <100mA Max <100mA Max <100mA Max
< 2V < 2V < 2V < 2V
25us 17us 250us 335us
20KHz 30KHz 2KHz 1.5KHz
Dark/Light Selectable Dark/Light Selectable Light C or C+I Independant for each channel
IP67 IP67 IP67 IP67
Aluminium Aluminium Aluminium ABS
-10o to 55oC -10o to 55oC -10o to 55oC -10o to 55oC
*M12 5-Pole Connector *M12 5-Pole Connector *M12 - 5 Pole Connector *M12 - 8 Pole Connector
M5
M5
TL46-WL-815 TL46-WL-815L TL46-WFL-815 TL46-WFL-815L LD46-UL-715 -
- - -
- - -- - -
- - S65-PA-5-V09-NNNZ
- - -- - S65-PA-5-V09-PPPZ LIMIT & PRESSURE SWITCHES & SENSORS
-- - M12 Connector
-- -
For sensor cable and accessories see pages 329-332
** For plug and cable use part *Available only for version with RS485
number CS-A1-03-G-03 serial connection (S65-PA-5-V09-xxxZ)
** For plug and cable use part
DAT number CS-A1-06-B-03
310
Type DC M18 DC LASER PNP/NPN NO-NC IP67 Laser Emitter
S50 SERIES Laser Diffuse Proximity Laser Retro-Reflective Laser Receiver 0-60m
10-30VDC
• Output: NPN or PNP NO-NC Red Laser 650nm²
• Output Current: ≤100mA max. Sensitivity trimmer
• Response Time 333µs Green/Yellow
• Housing Material: PBT 1.5kHz
• Temperature Range: -10 to 50°C
Sensing Distance 0-350mm 0-16m 0-60m
Supply Voltage 10-30VDC 10-30VDC 10-30VDC
Emission Red Laser 650nm² Red Laser 650nm² Red Laser 650nm²
Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
Output LED Green/Yellow Green/Yellow Green/Yellow
Switching Frequency 1.5kHz 1.5kHz 1.5kHz
Dimensions
OUTPUT: S50-PL-5-C01-PP S50-PL-5-B01-PP S50-PL-5-F01-PP –
PNP NO-NC M12 S50-PL-5-C01-NN S50-PL-5-B01-NN S50-PL-5-F01-NN –
NPN NO-NC M12 – – – S50-PL-5-G00-XG
Emmitter
Wiring Diagrams Laser Emitter
For Sensor Cables and
accessories see page 329-332
Type DC DC LASER PNP/NPN NO-NC IP67
S60 SERIES Laser diffuse proximity Laser Retro-Reflective Laser Receiver
• Output: NPN or PNP NO-NC
• Output Current: ≤100mA max.
• Response Time 250µs
• Housing Material: ABS
• Temperature Range: -10 to 50°C
LIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 0-600mm 0.1-20m 0-60m 0-60m
Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Emission Red Laser 650nm² Red Laser 650nm² Red Laser 650nm² Red Laser 650nm²
Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
Output LED Green/Yellow Green/Yellow Green/Yellow Green/Yellow
Switching Frequency 2kHz 2kHz 1.5kHz 1.5kHz
Dimensions
OUTPUT: S60-PL-5-C01-PP S60-PL-5-B01-PP S60-PL-5-F01-PP –
S60-PL-5-C01-NN S60-PL-5-B01-NN S60-PL-5-F01-NN –
PNP NO-NC M12 – – – S60-PL-5-G00-XG
NPN NO-NC M12
Emitter DAT
Wiring Diagrams
For Sensor Cables and
accessories see pages 329-332
311
ECONOMY U-SHAPE SENSORS 2mm SLOT SENSORS IP65
SR31 Series 30mm SR22 Series 1mm Slot Width 2mm 2mm
SR21 Series
Fork Slot • High 25kHz switching frequency
• Output Current: 200mA max. • Detection of semi-transparent
• Switching Frequency 10kHz
labels
• Detection of register marks on
transparents
• NPN and PNP output
• Output: NPN & PNP
• Output Current: 100mA Sci
Protection
• Housing Material: ZAMA
• Temperature Range:
-20 to 60°C
DC Supply Voltage 10-30VDC 24VDC DC Supply Voltage 10-30VDC 10-30VDC
Setting
Output LED Multi-turn Sensitivity Trimmer Trimmer Emission Infrared LED 880nm Green LED 535nm
Output
Operation Mode Red Output Red Output Setting Auto Set push-button Auto Set push-button
Housing Material
Wiring Diagrams NPN or PNP NPN & PNP Resolution 0.5mm 0.5mm
Dark/Light Configurable Dark and Light Output LED Yellow Yellow
ZAMA Aluminium Operating Mode Light/Dark Light/Dark
Wiring Diagrams
Light Mode Dark Mode
OUTPUT: For plug and cable use part number CS-B1-02-G-05/03
For sensor cable and accessories see pages 329-332
NPN & PNP (programmable) SR31 –
SR22-5-IR-OD
Dark Mode – SR22-5-IR-OL OUTPUT:
PNP & NPN M8
Light Mode – SR21-IR SR21-RG
ULTIMATE PRECISION FORK TYPE PHOTOELECTRIC SENSOR PNP/NPN MODE
Fork Width IP65 30mm 50mm 80mm 120mm
SRF SERIES 10-30VDC 10-30VDC 10-30VDC 10-30VDC
Red LED 640nm² Red LED 640nm² Red LED 640nm² Red LED 640nm²
• Nominal Voltage 10-30VDC Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer
• Output: NPN or PNP 0.3mm 0.5mm 0.5mm 0.8mm
• Output Current: 200mA Sci Protection Red LED Red LED Red LED Red LED
• Switching Frequency: 1.5kHz 333µs 333µs 333µs 333µs
• Housing Material: Anodised Aluminium Light/Dark Light/Dark Light/Dark Light/Dark
• Temperature Range: -10 to 60°C
• High resolution with visible red LED M8 Connector
emission
• Sensitivity adjustment trimmer
• Sturdy industrial metal housing with
glass lenses
DC Supply Voltage
Emission LIMIT & PRESSURE SWITCHES & SENSORS
Setting
Resolution
Output LED
Response Time
Operation Mode
Wiring Diagrams
OUTPUT: SRF-30-5-P SRF-50-5-P SRF-80-5-P SRF-120-5-P
PNP NO-NC Selectable M8
NPN NO-NC Selectable M8 SRF-30-5-N SRF-50-5-N SRF-80-5-N SRF-120-5-N
For plug and cable use part no. CS-B1-01-G-05 (axial) For sensor cable and accessories see pages 329-332
Lazer models available on request
DAT 312
SLOT SENSORS IP65 ULTRASONIC FORK SENSOR IP54
Slot Sensor SR23 Series 5mm Slot Sensor SRX3 Series 3mm
SR23 SERIES SRX3 SERIES For Transparent Label Detection
• Setting: Auto Set Push-Button
• Output: NPN & PNP
For Sensor Cables and 12 kHz 12 kHz Switching Speed 500Hz
accessories see pages 10-30VDC 10-30VDC DC Supply Voltage 10-30VDC
329-332 Infrared LED 850nm Infrared LED 850nm Emission Ultrasonic
0.5mm 0.5mm Max tape Speed 300m/min
Switching Speed Yellow. Green (Ready) Yellow. Green (Ready) Settings Dynamic/Static Teach-in
DC Supply voltage 100mA 100mA Output LED
Emission 2v 2v Output Current Yellow
Resolution 40us 40us Output 250mA
Output LED class 2 class 2 Response Time PNP/NPN
Output current Zinc Alloy Zinc Alloy Housing Material 1ms
Saturation voltage -25° to 55°C -25° to 55°C Ingress Protection Aluminium
Response Time 2m Cable M8 4-pole Connections IP54
Electrical Protection M12 5-Pole Connector M8 4-Pole Connector
Housing Material Cable M8 Connector Wiring Diagrams
Operating temperature M12 Connector - 5 Pin M8 Connector - 8 Pin
Connection
Wiring Diagrams
OUTPUT: SR23-2-IR-NH SR23-5-IR-NH OUTPUT: SRX3-5-US-M12-PNH SRX3-6-US-M8-PH
NPN SR23-2-IR-PH SR23-5-IR-PH PNP/NPN Dynamic SRX3-5-US-3-M12-PNH SRX3-6-US-3-M8-PH
PNP PNP/NPN Static
ULTRASONIC SENSORS FOR MEASUREMENT AND INSPECTION IP67
Type DC M18 M30 M50
US SERIES
• Nominal Voltage: 10-30VDC
• Output: NPN & PNP / 0-10VDC /
4-20mA
• Output Current: 100mA max.
• Complete Range
Sensing Distance 30-300mm 100-1000mm 200-2000mm 0.2-8m
Setting Teach-in Or Remote Input Teach-in Push button / Remotely /
Analogue Push Button
Output LED Yellow-Green Output / Red Power Yellow Output / Green Power ON / Green Power On / Red Signal /
Red Signal Yellow, Red Output
LIMIT & PRESSURE SWITCHES & SENSORS Housing Material Polyester PBT ABS Polycarbonate
Operating Temperature -25° to 55°C -40° to 70°C -20° to 70°C
Connections M12 5-pole Connector M12 4-pole Connector M12 5-pole Connector
Wiring Diagrams
M12 4-POLE CONNECTOR M12 5-POLE CONNECTOR
Analogue Analogue
NPN Output
PNP Output
Digital Digital
OUTPUT:
NPN & PNP US18-PA*-5-N03-OH US30-PR-5-N13-OH US30-PR-5-N23-OH US50-PR-5-N43-OH
Analogue Output 0 - 10 VDC US18-PA*-5-N03-VH US30-PR-5-N13-VH US30-PR-5-N23-VH US50-PR-5-N43-IVH
Analogue Output 4 - 20 mA US18-PA*-5-N03-IH US30-PR-5-N13-IH US30-PR-5-N23-IH (0-10V / 4-20mA Configurable Output)
* For radial type replace A with R e.g. US18-PR-5-N03-OH For sensor cable and accessories see pages 329-332
313 DAT
TIME OF FLIGHT LASER MEASUREMENT DISTANCE SENSORS
Type DC Analogue Distance Analogue Distance Analogue Distance Analogue Distance Analogue Distance
S80 SERIES
S80 Series S80 Series S80 Series S80 Series S81 Series Cost Effective
Distance 0.3-4m 0.3-7m 0.3-20.3m (on R80 reflector) 0.3-100.3m (on R80 reflector) 0.3-4m
DC Supply Voltage
Digital Resolution 15-30VDC 15-30VDC 15-30VDC 15-30VDC 24VDC +/-20%
Linearity
Switching Frequency 0.9mm 0.4mm 0.6mm 6mm
Light Emission
Response Time 0.3% 0.3% 0.25% 0.15% <1%
Serial Interface
Settings 100Hz(normal)/500Hz(fast) 100Hz 100Hz(normal)/500Hz(fast) 100Hz(normal)/500Hz(fast) 80Hz
Output
Red Laser cl.2 Red Laser cl.2 Red Laser cl.2 Red Laser cl.2 Red Laser 665nm, cl.2
Contact
Connection 5ms(normal)/1ms(fast) 5ms 5ms(normal)/1ms(fast) 5ms(normal)/1ms(fast) 5ms
Electrical Protection
Housing Material RS485 RS485 RS485 RS485 -
Ingress Protection
Operating Temperature Teach-in push-button Teach-in push-button Teach-in push-button Teach-in push-button Teach-in push-button
Dimensions
2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2PNP or NPN outputs
1PNP or NPN alarm output
(only S81...M) 1analogue
0-10V output (S81...Y)
NO NO NO NO -
M12 8-pole connector M12 8-pole connector M12 8-pole connector M12 8-pole connector M12 5-pole connector
Class 2 Class 2 Class 2 Class 2 Class 2
Aluminium Aluminium Aluminium Aluminium ABS
IP67 IP67 IP67 IP67 IP67
-10° to 50°C -10° to 50°C -10° to 50°C -10° to 50°C -10° to 50°C
S80 S81
OUTPUT:
2 x PNP 4 - 20mA S80-MH-5-Y09-PP*IZ S80-MH-5-YL09-PP*IZ S80-MH-5-Y19-PP*IZ S80-MH-5-Y29-PP*IZ -
- - S81-PL-5-M03-PP*C
2 x PNP 1 x PNP Alarm B- ackground suppression - - - S81-PL-5-Y03-PP*V
- - S81-PL-5-Y03-PPVK
2 x PNP 0-10V Analogue - - LIMIT & PRESSURE SWITCHES & SENSORS
S80L-Y S81-M S81-Y
2 x PNP Scalable 0-10V Analogue - -
Wiring Diagrams *For NPN replace PP with NN
E.g. S80-NG-5-Y09-NN
Detection Diagrams For plug and cable use part no. S81 Series
CS-A1-06-B-03.Use only R80 reflector
S80 Series
DAT 314
DC FIBRE OPTIC AMPLIFIERS AND CABLES IP65 DIN RAIL
Type DC Through Beam + Proximity Through Beam + Proximity Through Beam + Proximity
S7 SERIES
• 10 bit resolution models with 500µs response for
high operating distances
• 12 bit resolution models with 50µs response and
4 digit display for high speed
• Cost-effective models with multiturn trimmer
adjustment
• EASYtouch™ push-button setting with remote
control, keylock and output delay
• Ultra-thin housing with CLEARLOCK™ patented
fibre fixing system
Switching Frequency 1KHz 5KHz 10KHz
Sensing Distance 100mm Prox. 300mm Through Beam 50mm Prox. 300mm Through Beam 25mm Prox. 75mm Through Beam
DC Supply Voltage 12-24VDC ±10% 12-24VDC ±10% 12-24VDC ±10%
Emission Red LED 670nm Red LED 670nm White LED 460-630nm
Setting Teach-in push-button Teach-in push-button Teach-in push-button
Output LED Yellow/Green/Red error Yellow/Green/Red error Yellow/Green/Red error
Output PNP or NPN PNP or NPN PNP or NPN
Contact NO NO NO
Output current ≤100ma ≤100ma ≤100ma
Saturation Voltage ≤2V ≤2V ≤2V
Response Time 500µS 100µs 500µs
Timing Function 20ms minimum out ON 20ms minimum out ON 20ms minimum out ON
Operation Mode light with EASYtouch™ light with EASYtouch™ light with EASYtouch™
Plug Type
Wiring Diagrams
OUTPUT: NPN output PNP output
PNP NO M8 Plug S7-6-E-P – –
– –
NPN NO M8 Plug S7-6-E-N S7-5-E-P –
S7-5-E-N –
PNP NO M8 Plug Dispaly – S7-2-E-P S7-1-E-P
S7-2-E-N S7-1-E-N
NPN NO M8 Plug Display –
PNP NO Cable Display –
NPN NO Cable Display –
For plug and cable use part number CS-B1-02-G-05/03
Fibre Optic Cables Stainless Steel Protective Metal Sheath 2m
Optic Function Terminal/Tips Fibre Type Length Part Number Part Number Suitable Fibres
Coaxial Proximity M6 x 1mm Standard 1mm 2m OF-36-ST-20 AF-7 M6 x 0.75mm fibres OF-42-xx
OF-18-ST-10
Proximity M6 x 1mm Standard 1mm 1m OF-22-ST-20 AF-9 M4 x 0.7mm fibres OF-43-xx**
OF-26-TN-10
LIMIT & PRESSURE SWITCHES & SENSORS Proximity M6 x 1mm* Standard 1mm 2m OF-42-ST-20
OF-42-HP-20
Proximity M3 x 0.5mm Thin 0.5mm 1m OF-19-ST-10
OF-23-ST-20
Proximity M6 x 0.75mm Standard 1mm 1m OF-25-TN-10
OF-43-ST-20
Proximity M6 x 0.75mm High Efficiency 1.5mm 2m OF-43-HP-20
Through Beam M4 x 0.7mm Standard 1mm 1m
Through Beam M4 x 0.7mm* Standard 1mm 2m
Through Beam M2 x 0.4mm Thin 0.5mm 1m
Through Beam M4 x 0.7mm Standard 1mm 1m AF-7 Dimensions
Through Beam M4 x 0.7mm High Efficiency 1.5mm 2m AF-9 Dimensions
Application Fibre Optics ** 2 Sheaths have to be ordered for both the emitter-receiver fibres
Optic Function Terminal/Emission Fibre Length Part Number
Through Beam Axial, 16 Beam Array 2m OFA-1-AE-20
Through Beam Radial, 16 Beam Array 2m OFA-1-AS-20
Proximity Axial, 32 Beam Array 2m OFA-2-AE-20
Proximity Radial, 32 Beam Array 2m OFA-2-AS-20
* A bendable stainless steel extension 90mm long protrudes from the threaded optic head
315 DAT
PHOTOELECTRIC SENSORS
Long Range Photoelectric Sensors IP54
Type Through Beam Kits Through Beam Kit for
Note: Each kit includes emitter and receiver. Automatic Doors
Receiver Emitter
Receiver Emitter Receiver Emitter Receiver Emitter Battery operated 9V
Ideal for P41 – surface mount P40 – flush mount emitter-150 days minimum
automatic gates
Solar cell power supply on
request Note: Each kit includes 1 pair of projectors.
10M
Switching Distance 15M 35M 55M 15M
One Beam Selection
Available Receiver & Emitter Receiver & Emitter Receiver & Emitter Receiver & Emitter Infrared (875hm)
Emission Infrared (875nm) Infrared (875nm) Infrared (875nm) Relay: 8A @ 250VAC
70mA
Output 2 Relay SPDT Relay: 1A @ 24VDC 2 Relay
Output and activated thru beam indicator
Consumption 40mA 40mA 70mA Supply indicator
Present
Yellow LED Output Indicator Output indicator Output Indicator 5Hz
200mS
Green LED Supply Indicator Supply indicator Supply Indicator ≤ 300mS
-20° to 60°C
Sensitivity Adjustment – – – > 5000 Lux
Switching Frequency 50Hz - 60Hz 5Hz 1Hz Amplifiers IP54. Projectors IP65
Amplifiers ABS. Projectors Body – Lenses: methacrylate
Response Time – – 500mS
350 g
Start Up Delay ≤ 300mS ≤ 300mS ≤ 300mS 12VAC/DC BP10-120
Ambient -20° to 60°C -20° to 60°C -20° to 60°C 24VAC/DC BP10-240
Light Immunity 230VAC/DC BP10-220
> 5000 Lux > 5000 Lux > 5000 Lux(1) Wiring Diagram
Protection Degree IP54 IP54 IP54 8A
Housing Material PMMA Housing: glass-filled nylon – Filter: methacrylate
Weight (Approx) 160 g 315 g 340 g
12-24VAC/DC P63 P 41 P40 P44
9V alkaline battery P44
230VAC/DC – – – –
Wiring Diagram Wiring Diagram for Wiring Diagram for P44
EMITTER P63, P40 & P41 EMITTER RECEIVER
RECEIVER
12VAC/DC
or 24VAC/DC
Accessories for P41 8A
▼ C41080 105 Anti-Vandalism Projector Dimensions
▼ Box (grey)
500 LIMIT & PRESSURE SWITCHES & SENSORSCharacteristic Curve BP10
▼ 88
S410 ▼ 75 316
15 ▼
▼
▼ 85
77
4.5 Metal Box ▼
42 wall mounting
(grey) 28 SI41
30 Metal Post (grey)
65
Accessories for P40 85 Solar Accessory for P44
C340 Box for wall SCP44
75 mounting
Battery operated 9V emitter-150
(grey) 530 days minimum. Solar cell power
supply on request.
75
▼
S340
Metal Post (grey) ▼
60
DAT