The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by phil.kretzschmar, 2021-06-04 05:16:39

San Ace 2021

m3h

■ Wiring DiagramAC power supply

Standard

A
C



フFァANン

with Sensor For sensor circuit 12 V (ITEM-30)
5 V (ITEM-20)
For fan power supply
AC power supply Sensor circuit Brown +4.5 to 5.5 V Sensor circuit Brown
CA +9.6 to 14.4 V

源 Yellow 100 mA max. Yellow 200 mA max.
+27.6 V max. +27.6 V max.
フFァANン Pull-up resistor Pull-up resistor
Sensor output
Black GND (0 V) Black Sensor output
GND (0 V)

GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated.

■ Options page: p. 584 Resin finger guards page: p. 591
Model no.: 109-1001G
Finger guards
Model no.: 109-099E, 109-099H, 109-099C

Resin filter kits page: p. 592 Plug cord page: pp. 594 to 595

Model no.: 109-1001F13 (13PPI), 109-1001F20 (20PPI), Model no.: 489-016-L10, 489-016-L21, 489-047-L10,
109-1001F30 (30PPI), 109-1001F40 (40PPI) 489-047-L21

AC Fan 92 mm sq. AC

551CATALOG No. C1111B001 '21.2.IT

AC Fan

120×120×25 mm
San Ace 120
Only standard fans (without sensors) have acquired CSA certification.

■ General Specifications

· Material �������������� Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1)
· Expected life ������������ See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)

Expected life at 40°C is for reference only.
· Motor structure ���������� Shaded coil motor
· Motor protection function ������ Locked rotor burnout protection, Reverse polarity protection

For details, please refer to p. 599.
· Dielectric strength ��������� 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame)
· Dielectric strength (with sensor) ��� 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame)

50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame)
· Insulation resistance �������� 10 MΩ or more with a 500 VDC megger
· Sound pressure level (SPL) ����� At 1 m away from the air inlet
· Operating voltage range ������ Voltage of each model ±10%
· Storage temperature �������� -30 to +70˚C (Non-condensing)
· Sensor-Purpose lead wire ������ Brown Black Sensor Yellow
· Mass ��������������� 370 g/390 g (with Sensor)

■ Specifications
Standard

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109S085
109S084 100 50/60 0.16/0.14 0.19/0.17 2500/2900 48 /51.9 0.193/0.216 38/41
109S088 115 0.16/0.15
109S087 200 13.5/12 0.14/0.12 0.1 /0.09 2200/2350 1.95/2.3 68.9/81.3 29.4/26.5 0.118/0.106 34/35
109S081 230 0.08/0.07 0.08/0.07 1400/1600 14.7/18.6 0.059/0.075 24/27
109S083 100 0.11/0.1
109S082 115 0.07/0.06 0.1 /0.09 25000/60˚C
109S089 200 0.07/0.06 (56000/40˚C)
109S086* 230 0.11 0.06/0.05 -30 to +60
100 0.15/0.13
AC Fan 120 mm sq. AC 9.5/8.5 0.1 1.7 /1.8 60.1/63.6
0.07 1.1 /1.25 38.9/44.2

0.06

12/10 0.14/0.12

*These are low-speed models.

with Sensor

For sensor specifications, please refer to p. 602. Sensor specification differs depending on the fan's speed specification.
For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109S485-20
For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109S485-30

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109S485
109S484 100 50/60 0.16/0.14 0.19/0.17 2500/2900 48 /51.9 0.193/0.216 38/41
109S488 115 1400/1600 14.7/18.6 0.059/0.075 24/27
109S487 200 13.5/12 0.14/0.12 0.16/0.15 1.95/2.3 68.9/81.3 -10 to +60 25000/60˚C
109S486* 230 0.08/0.07 0.1 /0.09 (56000/40˚C)
100
0.07/0.06 0.08/0.07

12/10 0.14/0.12 0.15/0.13 1.1 /1.25 38.9/44.2

*These are low-speed models.

Note:These are Short LeadTime Service applicable models. Contact your point of sale for stock availability. For more information on the service, see p. 654.

552 CATALOG No. C1111B001 '21.2.IT

■ Set Models

Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 655.

Order no. Set items

Fan Voltage Low-speed sensor Plug cord* Finger guards Mounting screws

ST1-109S085 109S085 100 V ◯ (5 V) 489-016-L10 109-019E M3×40 mm (4 screws)
ST1-109S084 109S084 115 V ◯ (12 V) 489-016-L10 109-019E
ST1-109S088 109S088 200 V ◯ (5 V) 489-016-L10 109-019E
ST1-109S087 109S087 230 V ◯ (12 V) 489-016-L10 109-019E
ST1-109S081 109S081 100 V ◯ (5 V) 489-016-L10 109-019E
ST1-109S083 109S083 115 V ◯ (12 V) 489-016-L10 109-019E
ST1-109S082 109S082 200 V ◯ (5 V) 489-016-L10 109-019E
ST1-109S089 109S089 230 V ◯ (12 V) 489-016-L10 109-019E
ST1-109S086 109S086 ◯ (5 V) 489-016-L10 109-019E
ST1-109S485-20 109S485-20 100 V ◯ (12 V) 489-016-L10 109-019E
ST1-109S485-30 109S485-30 489-016-L10 109-019E
ST1-109S484-20 109S484-20 115 V 489-016-L10 109-019E
ST1-109S484-30 109S484-30 489-016-L10 109-019E
ST1-109S488-20 109S488-20 200 V 489-016-L10 109-019E
ST1-109S488-30 109S488-30 489-016-L10 109-019E
ST1-109S487-20 109S487-20 230 V 489-016-L10 109-019E
ST1-109S487-30 109S487-30 489-016-L10 109-019E
ST1-109S486-20 109S486-20 100 V 489-016-L10 109-019E
ST1-109S486-30 109S486-30 489-016-L10 109-019E

* PSE compatible.

■ Airflow - Static Pressure Characteristics
Standard

109S085, 109S084, 109S088, 109S087 109S081, 109S083, 109S082, 109S089 109S086

(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)

0.30 0.15 0.12 30
70 0.10
Static静pr圧essure 60 Hz 100 V/115 V/200 V/230 V Static静pr圧essure 30 60 Hz 100 V/115 V/200 V/230 V Static静pr圧essure 0.08 20 60 Hz 100 V
0.25 60 50 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 0.06 50 Hz 100 V
0.10 0.04 10
0.20 50 1 2 3 (m3/min) 20 0.02 1 2 (m3/min)
20 40 60 80 100 (CFM) 20 40 60 80 (CFM)
0.15 40 0.05 10 00 AC Fan 120 mm sq. AC
30 Ai風rfl量ow 0 Ai風rfl量ow
00 1 2 3 (m3/min)
0.10
20 0 20 40 60 80 100 (CFM)

0.05 10 Ai風rfl量ow

00

0

with Sensor

109S485, 109S484, 109S488, 109S487 109S486

Static静pr圧essure(inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V Static静pr圧essure(inch H2O) (Pa) 60 Hz 100 V
50 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V
0.30 0.12 30
70 1 2 3 (m3/min) 0.10 12 (m3/min)
20 40 60 80 100 (CFM) 0.08 20 20 40 60 80
0.25 60 0.06 100 (CFM)
Ai風rfl量ow 0.04 10 Ai風rfl量ow
0.20 50 0.02

0.15 40 00
30 0

0.10
20

0.05 10

00

0

553CATALOG No. C1111B001 '21.2.IT

■ Dimensions (unit: mm)

Standard 8-ø3.7

Mou取n付tin用g穴hole MM44××00..77, 深6 m6 m deep

Eアaーrthスgr用ouタndッtプap

119±0.5
104.8±0.5

104.8±0.5 3.5 3.5
119±0.5
25±0.5

2266m以a下x.

Rota回tin転g 方di向rection Air風flo吹w出d方ire向ction

with Sensor When mounting the model with a sensor, please screw-mount through both flanges as it has a sensor box.

Sセeンnsサor用-pリurーpoドse線lead wire
L長eさng3t0h03L00L
AWG28
1.5 UL 1007 8-ø3.7

9.5 41 Mo取u付nti用ng穴hole

119±0.5 MM44××00.7.7, 深6 m6 m deep
104.8±0.3
Eアaーrthスg用roタunッdプtap
79 9.5

1.5

104.8±0.3 3.5 3.5
119±0.5
25.3±0.5
Rota回tin転g方di向rection
AC Fan 120 mm sq. AC 26 m以a下x.

ø117 Air風flo吹w出d方ire向ction
104.8±0.3
■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)

Inlet side, Outlet side 4-ø4 115 4-ø4
104.8±0.3
104.8±0.3

ø127
104.8±0.3

115

554 CATALOG No. C1111B001 '21.2.IT

■ Wiring DiagramAC power supply

Standard

A
C



フFァANン

with Sensor For sensor circuit 12 V (ITEM-30)
5 V (ITEM-20)
For fan power supply
AC power supply Sensor circuit Brown +4.5 to 5.5 V Sensor circuit Brown
CA +9.6 to 14.4 V

源 Yellow 100 mA max. Yellow 200 mA max.
+27.6 V max. +27.6 V max.
フFァANン Pull-up resistor Pull-up resistor
Sensor output
Black GND (0 V) Black Sensor output
GND (0 V)

GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated.

■ Options

Finger guards page: p. 585 Resin finger guards page: p. 591
Model no.: 109-1000G
Model no.: 109-019E, 109-019K, 109-019C, 109-019H

Resin filter kits page: p. 592 Plug cord page: pp. 594 to 595

Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI), Model no.: 489-016-L10, 489-016-L21, 489-047-L10,
109-1000F30 (30PPI), 109-1000F40 (40PPI) 489-047-L21

AC Fan 120 mm sq. AC

555CATALOG No. C1111B001 '21.2.IT

AC Fan

120×120×38 mm
San Ace 120
Certifications vary by model no. Please refer to pp. 614 to 615.

■ General Specifications

· Material �������������� Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1)
· Expected life ������������ See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)

Expected life at 40°C is for reference only.
· Motor structure ���������� Shaded coil motor
· Motor protection function ������ Locked rotor burnout protection, Reverse polarity protection

For details, please refer to p. 599.
· Dielectric strength ��������� 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and G terminal)
· Dielectric strength (with sensor) ��� 50/60 Hz 1500 VAC 1 minute (between AC input terminal and G terminal)

50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame)
· Insulation resistance �������� 10 MΩ or more with a 500 VDC megger
· Sound pressure level (SPL) ����� At 1 m away from the air inlet
· Operating voltage range ������ Voltage of each model ±10%
· Storage temperature �������� -30 to +70˚C (Non-condensing)
· Sensor-Purpose lead wire ������ Brown Black Sensor Yellow
· Mass ��������������� 550 g/580 g (with Sensor)

■ Specifications
Standard

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109S075UL
109S074UL 100 18/16 0.24/0.21 0.32/0.28 2700/3100 2.5 /2.9 88.3/102.5 57.9/68.7 0.233/0.276 42/45
109S078UL 115 0.21/0.18 0.27/0.24
109S072UL 200 14/12 0.12/0.1 0.16/0.14 40/43
109S005 230 0.11/0.09 0.14/0.13
109S005UL 14/12 38/40
109S024 100 13/11 0.18/0.16 0.25/0.22 30/32
109S024UL 7/7 28/28
AC Fan 120 mm sq. AC 109S008 120 10/10 0.16/0.14 0.21/0.18 55.9/65.7 0.224/0.264 30/31
109S008UL 115 7/7 2700/3100 2.35/2.7 83 / 95.4 28/28
109S025 11/11 30/32
109S025UL 200 0.09/0.08 0.13/0.11
109S029UL 230 50/60
109S013 0.08/0.07 0.11/0.09 -30 to +60 25000/60˚C
109S013UL 0.18/0.16 0.23/0.21 2450/2700 2.15/2.35 76 / 83 (56000/40˚C)
109S006* 0.16/0.14 0.16/0.15 1800/2000 1.55/1.75 54.8/ 60.8
100 44.1/49.0 0.177/0.197
23.5/26.4 0.094/0.106

109S006UL* 115 0.1 /0.09 0.1 /0.09 1650/1700 1.45/1.5 51.2/ 53 17.6/17.6 0.071/0.071
109S010* 200 0.13/0.11 0.13/0.11 1800/1900 1.56/1.64 55 / 57.9 20 /20.6 0.08 /0.083
109S010UL* 240 0.05/0.04 0.05/0.04 1650/1700 1.45/1.5 51.2/ 53 17.6/17.6 0.071/0.071
0.06/0.05 0.06/0.05 1800/1950 1.58/1.68 55.8/ 59.3 20.6/21.6 0.083/0.087

*These are low-speed models.

556 CATALOG No. C1111B001 '21.2.IT

with Sensor

For sensor specifications, please refer to p. 602. Sensor specification differs depending on the fan's speed specification.
For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109S405UL-20
For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109S405UL-30

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109S405UL
109S424UL 100 14/12 0.18/0.16 0.25/0.22 55.9/65.7 0.224/0.264 40/43
109S408UL 115 7/6
109S425UL 200 18/16 0.16/0.14 0.21/0.18 2700/3100 2.35/2.7 83 / 95.4 44.1/49.0 0.177/0.197 38/40
109S429UL 230 0.09/0.08 0.13/0.11 17.7/17.7 0.071/0.071 28/28
109S406UL*
109S475UL 0.08/0.07 0.11/0.09 57.9/68.7 0.233/0.276 42/45
109S474UL
109S478UL 100 50/60 0.18/0.16 0.23/0.21 2450/2700 2.15/2.35 76 / 83 -10 to +60 25000/60˚C
109S472UL (56000/40˚C)
0.09/0.08 0.1 /0.09 1650/1700 1.45/1.5 51 / 53

100 0.24/0.21 0.32/0.28
115
200 0.21/0.18 0.27/0.24 2700/3100 2.5 /2.9 88.3/102.4
230 0.12/0.1 0.16/0.14

0.11/0.09 0.14/0.13

*These are low-speed models.

Note:These are Short LeadTime Service applicable models. Contact your point of sale for stock availability. For more information on the service, see p. 654.

For the San Ace 120AD 9AD type 120×120×38 mm fan, please refer to p. 519.

This fan works while internally converting AC power into DC power, providing the superior performance of a DC fan with the flexibility of AC input.

■ Set Models

Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 655.

Order no. Set items

Fan Voltage Low-speed sensor Plug cord* Finger guards Mounting screws

ST1-109S075UL 109S075UL 100 V 489-037-L10 109-019E M3×55 mm (4 screws) AC Fan 120 mm sq. AC
ST1-109S074UL 109S074UL 115 V 489-037-L10 109-019E
ST1-109S078UL 109S078UL 200 V 489-037-L10 109-019E
ST1-109S072UL 109S072UL 230 V 489-037-L10 109-019E
ST1-109S005 109S005 100 V 489-006-L10 109-019E
ST1-109S005UL 109S005UL 120 V 489-037-L10 109-019E
ST1-109S024 109S024 115 V 489-006-L10 109-019E
ST1-109S024UL 109S024UL 200 V 489-037-L10 109-019E
ST1-109S008 109S008 489-006-L10 109-019E
ST1-109S008UL 109S008UL 230 V 489-037-L10 109-019E
ST1-109S025 109S025 489-006-L10 109-019E
ST1-109S025UL 109S025UL 100 V 489-037-L10 109-019E
ST1-109S029UL 109S029UL 489-037-L10 109-019E
ST1-109S013 109S013 100 V 489-006-L10 109-019E
ST1-109S013UL 109S013UL 115 V 489-037-L10 109-019E
ST1-109S006 109S006 489-006-L10 109-019E

ST1-109S006UL 109S006UL 489-037-L10 109-019E

ST1-109S010 109S010 200 V 489-006-L10 109-019E

ST1-109S010UL 109S010UL 200 V ◯ (5 V) 489-037-L10 109-019E
240 V ◯ (12 V)
ST1-109S405UL-20 109S405UL-20 100 V ◯ (5 V) 489-037-L10 109-019E
ST1-109S405UL-30 109S405UL-30 115 V ◯ (12 V) 489-037-L10 109-019E
ST1-109S424UL-20 109S424UL-20 200 V ◯ (5 V) 489-037-L10 109-019E
ST1-109S424UL-30 109S424UL-30 230 V ◯ (12 V) 489-037-L10 109-019E
ST1-109S408UL-20 109S408UL-20 100 V ◯ (5 V) 489-037-L10 109-019E
ST1-109S408UL-30 109S408UL-30 100 V ◯ (12 V) 489-037-L10 109-019E
ST1-109S425UL-20 109S425UL-20 100 V ◯ (5 V) 489-037-L10 109-019E
ST1-109S425UL-30 109S425UL-30 115 V ◯ (12 V) 489-037-L10 109-019E
ST1-109S429UL-20 109S429UL-20 200 V ◯ (5 V) 489-037-L10 109-019E
ST1-109S429UL-30 109S429UL-30 230 V ◯ (12 V) 489-037-L10 109-019E
ST1-109S406UL-20 109S406UL-20 ◯ (5 V) 489-037-L10 109-019E
ST1-109S406UL-30 109S406UL-30 ◯ (12 V) 489-037-L10 109-019E
ST1-109S475UL-20 109S475UL-20 ◯ (5 V) 489-037-L10 109-019E
ST1-109S475UL-30 109S475UL-30 ◯ (12 V) 489-037-L10 109-019E
ST1-109S474UL-20 109S474UL-20 ◯ (5 V) 489-037-L10 109-019E
ST1-109S474UL-30 109S474UL-30 ◯ (12 V) 489-037-L10 109-019E
ST1-109S478UL-20 109S478UL-20 ◯ (5 V) 489-037-L10 109-019E
ST1-109S478UL-30 109S478UL-30 ◯ (12 V) 489-037-L10 109-019E
ST1-109S472UL-20 109S472UL-20 489-037-L10 109-019E
ST1-109S472UL-30 109S472UL-30 489-037-L10 109-019E

* PSE compatible.

557CATALOG No. C1111B001 '21.2.IT

■ Airflow - Static Pressure Characteristics
Standard

109S075UL, 109S074UL, 109S078UL, 109S005, 109S005UL, 109S024, 109S029UL
109S072UL 109S024UL, 109S008, 109S008UL,
109S025, 109S025UL

Static静pr圧essure (inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V Static p静r圧essure(inch H2O) (Pa) 60 Hz 100 V/115 V/120 V/200 V/230 V Static p静r圧essure(inch H2O) (Pa) 60 Hz 100 V
50 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/120 V/200 V/230 V 50 Hz 100 V
80 0.30 0.30
0.30 1 2 3 (m3/min) 70 70 1 2 3 (m3/min)
20 40 60 80 100 120 (CFM) 20 40 60 80 100 120 (CFM)
70 0.25 60 0.25 60
0.25 60 Ai風rfl量ow Ai風rfl量ow
0.20 50 0.20 50
0.20 50
0.15 40 0.15 40 0.15 40
30 30
30
0.10 20 0.10 0.10
0.05 10 20 20

00 0.05 10 0.05 10

0 00 1 2 3 (m3/min) 00

0 20 40 60 80 100 120 (CFM) 0

Ai風rfl量ow

109S013, 109S013UL 109S006, 109S006UL, 109S010,
109S010UL
(inch H2O) (Pa)
(inch H2O) (Pa)
30
0.12 30
0.10
Static p静re圧ssure 60 Hz 100 V Static p静r圧essure 0.10 60 Hz 115 V/240 V
20 50 Hz 100 V 0.08 20 50 Hz 115 V/240 V
0.06 60 Hz 100 V/200 V
50 Hz 100 V/200 V

0.05 0.04 10
10

0.02

00 1 2 3 (m3/min) 00 0.5 1.0 1.5 2.0 (m3/min)

0 20 40 60 80 100 (CFM) 0 10 20 30 40 50 60 70 (CFM)

Ai風rfl量ow Ai風rfl量ow

■ with Sensor
AC Fan 120 mm sq. AC
109S405UL, 109S424UL, 109S408UL, 109S429UL 109S406UL
Static p静re圧ssure109S425UL

(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)

0.30 0.30 0.12 30
70 70
60 Hz 100 V/115 V/200 V/230 V 60 Hz 100 V 0.10
0.25 60 50 Hz 100 V/115 V/200 V/230 V 0.25 60 50 Hz 100 V
Static p静re圧ssure Static p静r圧essure 0.08 20
0.20 50 0.20 50 1 2 3 (m3/min)
20 40 60 80 100 (CFM) 0.06
0.15 40 0.15 40
30 30 Ai風rfl量ow 0.04 10 60 Hz 100 V
1.5 (m3/min)
0.10 0.10 0.02
20 20
50 Hz 100 V
0.05 10 0.05 10

00 1 2 3 (m3/min) 00 00 0.5 1.0

0 20 40 60 80 100 (CFM) 0 0 10 20 30 40 50 60 (CFM)

Ai風rfl量ow Ai風rfl量ow

109S475UL, 109S474UL, 109S478UL,
109S472UL

Static p静r圧essure(inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V
50 Hz 100 V/115 V/200 V/230 V
0.35
80

0.30 70
0.25 60

0.20 50

0.15 40
30

0.10 20
0.05 10

00 1 2 3 (m3/min)

0 20 40 60 80 100 (CFM)

Ai風rfl量ow

558 CATALOG No. C1111B001 '21.2.IT

■ Dimensions (unit: mm)

Standard

119±0.8 6.8±0.3 38±0.5 6.5±0.3
104.8±0.3
(4) (4)
119±0.8
104.8±0.3 AIR-
FLOW

8-ø3.7 Rota回tin転g方di向rection Air風flo吹w 出di方rec向tion

Mo取u付nti用ng穴hole

with Sensor When mounting the model with a sensor, please screw-mount through both flanges as it has a sensor box.

119±0.8 38±0.5
104.8±0.3
6.8±0.3 6.5±0.3

(4) (4)

119±0.8 長セASLAleeeWンaWnnさdGサgswGot2用h3r8i-r0リ3pe20u0ー80rLpLドo線se AIR-
104.8±0.3 UULL10100707 FLOW

8-ø3.7 Rota回tin転g 方dir向ection Air風flo吹w出di方re向ction

Moun取tin付g用ho穴le

■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)

Inlet side 4-ø4 Outlet side 4-ø4 AC Fan 120 mm sq. AC
104.8±0.3
115

104.8±0.3

ø117
104.8±0.3

ø127
104.8±0.3

115

559CATALOG No. C1111B001 '21.2.IT

AC power supply■ Wiring Diagram

Standard

A
C



フFァANン

with Sensor For sensor circuit 12 V (ITEM-30)
5 V (ITEM-20)
For fan power supply
AC power supply Sensor circuit Brown +4.5 to 5.5 V Sensor circuit Brown
AC +9.6 to 14.4 V

源 Yellow 100 mA max. Yellow 200 mA max.
+27.6 V max. +27.6 V max.
フFァANン Pull-up resistor Pull-up resistor
Sensor output
Black GND (0 V) Black Sensor output
GND (0 V)

GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated.

■ Options

Finger guards page: p. 585 Resin finger guards page: p. 591
Model no.: 109-1000G
Model no.: 109-019E, 109-019K, 109-019C, 109-019H

Resin filter kits page: p. 592 Filter kits page: p. 593
Model no.: 109-018
Model no.: 109-1000F13 (13PPI), 109-1000F20 (20PPI),
109-1000F30 (30PPI), 109-1000F40 (40PPI)

Screen kits page: p. 593 Plug cord page: pp. 594 to 595
Model no.: 109-020
Exclusive for fans without UL at the end of the model number.
AC Fan 120 mm sq. AC Model no.: 489-006-L10, 489-006-L21, 489-006-L35

Exclusive for fans with UL at the end of the model number.
Model no.: 489-037-L10, 489-037-L21, 489-037-L35,

489-007-L10, 489-007-L21

560 CATALOG No. C1111B001 '21.2.IT

AC Fan

160×160×51 mm
San Ace 160
Only standard fans (without sensors) have acquired CSA certification.

■ General Specifications

· Material �������������� Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1)
· Expected life ������������ See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)

Expected life at 40°C is for reference only.
· Motor structure ���������� Capacitor motor
· Motor protection function ������ Locked rotor burnout protection, Reverse polarity protection

For details, please refer to p. 599.
· Dielectric strength ��������� 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame)
· Dielectric strength (with sensor) ��� 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame)

50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame)
· Insulation resistance �������� 10 MΩ or more with a 500 VDC megger
· Sound pressure level (SPL) ����� At 1 m away from the air inlet
· Operating voltage range ������ Voltage of each model ±10%
· Storage temperature �������� -30 to +70˚C (Non-condensing)
· Sensor-Purpose lead wire ������ Brown Black Sensor Yellow
· Mass ��������������� 1100 g

■ Specifications
Standard

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109-601
109-604 100 50/60 0.43/0.35 0.72/0.7 2850/3350
109-602 115 0.62/0.61
109-603 200 37.5/33 0.39/0.31 0.36/0.35 7.2/8.5 254.4/300.4 156.8/166.6 0.63/0.669 56/60 -30 to +60 25000/60˚C
230 0.23/0.18 0.32/0.31 (56000/40˚C)

0.21/0.16

with Sensor AC Fan 160 mm sq. AC

For sensor specifications, please refer to p. 602. Sensor specification differs depending on the fan's speed specification.
For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109-641-20
For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109-641-30

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109-641
109-644 100 50/60 0.43/0.35 0.72/0.7 2850/3350
109-642 115 0.62/0.61
109-643 200 37.5/33 0.39/0.31 0.36/0.35 7.2/8.5 254.4/300.4 156.8/166.6 0.63/0.669 56/60 -10 to +60 25000/60˚C
230 0.23/0.18 0.32/0.31 (56000/40˚C)

0.21/0.16

Note:These are Short LeadTime Service applicable models. Contact your point of sale for stock availability. For more information on the service, see p. 654.

■ Set Models

Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 655.

Order no. Fan Voltage Low-speed sensor Set items Finger guards Mounting screws

ST1-109-601 109-601 100 V ◯ (5 V) Plug cord* 109-619E M5×20 mm (4 screws)
ST1-109-604 109-604 115 V ◯ (12 V) 109-619E
ST1-109-602 109-602 200 V ◯ (5 V) 489-1618-L10 109-619E
ST1-109-603 109-603 230 V ◯ (12 V) 489-1618-L10 109-619E
ST1-109-641-20 109-641-20 100 V ◯ (5 V) 489-1618-L10 109-619E
ST1-109-641-30 109-641-30 ◯ (12 V) 489-1618-L10 109-619E
ST1-109-644-20 109-644-20 115 V ◯ (5 V) 489-1618-L10 109-619E
ST1-109-644-30 109-644-30 ◯ (12 V) 489-1618-L10 109-619E
ST1-109-642-20 109-642-20 200 V 489-1618-L10 109-619E
ST1-109-642-30 109-642-30 489-1618-L10 109-619E
ST1-109-643-20 109-643-20 230 V 489-1618-L10 109-619E
ST1-109-643-30 109-643-30 489-1618-L10 109-619E
489-1618-L10
489-1618-L10

* PSE compatible.

561CATALOG No. C1111B001 '21.2.IT

■ Airflow - Static Pressure Characteristics

Standard with Sensor

109-601, 109-604, 109-602, 109-603 109-641, 109-644, 109-642, 109-643

(inch H2O) (Pa) (inch H2O) (Pa)

0.8 200 0.8 200

0.6 150 60 Hz 100 V/115 V/200 V/230 V 0.6 150 60 Hz 100 V/115 V/200 V/230 V
0.4 100 50 Hz 100 V/115 V/200 V/230 V 0.4 100 50 Hz 100 V/115 V/200 V/230 V
0.2 50Static p静re圧ssure 0.2 50
Static静pr圧essure

0 0 1 2 3 4 5 6 7 8 9 (m3/min) 0 0 1 2 3 4 5 6 7 8 9 (m3/min)
0 50 100 150 200 250 300 350 (CFM) 0 50 100 150 200 250 300 350 (CFM)

Ai風rfl量ow Ai風rfl量ow

■ Dimensions (unit: mm)

Standard +1 2288m以a下x. +1
160 0 51 0
8-ø5.5
M取ou付nti用ng穴hole 138.5±0.3 (4) (4)

MM44××00..77,深55mm deep
Eアaーrthスg用roタuッndプtap

+1 AIRFLOW
160 0 ROTATION

138.5±0.3

Rotat回in転g 方dir向ection Airfl風ow吹d出ir方ec向tion

with Sensor

8-ø5.5
Mo取un付tin用g 穴hole
AC Fan 160 mm sq. AC +1 2288m以a下x. +1
+1 160 0 51 0
160 0 (4) (4)
138.5±0.3 138.5±0.3
M4×0.7深, 55mm deep
Eアaーrthスg用roタuッndプtap

AIRFLOWROTATION

Rotat回in転g 方di向rection Sセeンnsサo用r-pリurーpドos線e lead wire
UALU長AeWWLLさn11GGg300t2200h080877L300L
Airflo風w吹d出ire方c向tion

■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)
Inlet side, Outlet side

157 4-ø5.7

138.5±0.3

ø175 138.5±0.3

157

562 CATALOG No. C1111B001 '21.2.IT

■ Wiring DiagramAC power supply

Standard

A
C



フFァANン

with Sensor For sensor circuit 12 V (ITEM-30)
5 V (ITEM-20)
For fan power supply
AC power supply Sensor circuit Brown +4.5 to 5.5 V Sensor circuit Brown
AC +9.6 to 14.4 V

源 Yellow 100 mA max. Yellow 200 mA max.
+27.6 V max. +27.6 V max.
フFァANン Pull-up resistor Pull-up resistor
Sensor output
Black GND (0 V) Black Sensor output
GND (0 V)

GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated.

■ Options page: p. 585 Plug cord page: pp. 594 to 595

Finger guards Model no.: 489-084-L10, 489-084-L21, 489-086-L10,
Model no.: 109-619E, 109-619H, 109-620 489-086-L21, 489-1618-L10, 489-1618-L21,
489-1618-L28, 489-1619-L10, 489-1619-L21

AC Fan 160 mm sq. AC

563CATALOG No. C1111B001 '21.2.IT

AC Fan Sidecut type

ø172×150×51 mm

San Ace 172

■ General Specifications

· Material �������������� Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1)
· Expected life ������������ See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)

Expected life at 40°C is for reference only.
· Motor structure ���������� Capacitor motor
· Motor protection function ������ Locked rotor burnout protection, Reverse polarity protection

For details, please refer to p. 599.
· Dielectric strength ��������� 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame)
· Insulation resistance �������� 10 MΩ or more with a 500 VDC megger
· Sound pressure level (SPL) ����� At 1 m away from the air inlet
· Operating voltage range ������ Voltage of each model ±10%
· Storage temperature �������� -30 to +70˚C (Non-condensing)
· Mass ��������������� 1000 g

■ Specifications

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109S301
109S304 100 50/60 27/25 0.33/0.25 0.65/0.64 147/196 0.59/0.787 51/56
109S302 115
109S303 200 0.29/0.22 0.55/0.54 2900/3500 5.3/6.4 187.3/226.1 -30 to +60 25000/60˚C
230 0.16/0.13 0.33/0.32 (56000/40˚C)

0.14/0.11 0.28/0.27

Note:These are Short LeadTime Service applicable models. Contact your point of sale for stock availability. For more information on the service, see p. 654.

■ Set Models

Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 655.

AC Fan ø172 mm AC Order no. Set items

Fan Voltage Low-speed sensor Plug cord(1) Finger guards Mounting screws

ST1-109S301 109S301 100 V 489-1619-L10 109-319E M4×25 mm (4 screws)(2)
ST1-109S304 109S304 115 V 489-1619-L10 109-319E
ST1-109S302 109S302 200 V 489-1619-L10 109-319E
ST1-109S303 109S303 230 V 489-1619-L10 109-319E

(1) PSE compatible.
(2)Though these are 2-hole or 3-hole frame mount types, 4 screws are included for extra.

■ Airflow - Static Pressure Characteristics

109S301, 109S304, 109S302, 109S303

(inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V

0.8 200
0.6 150
Static静pr圧essure
0.4 100 50 Hz 100 V/115 V/200 V/230 V

0.2 50

00 2 4 6 8 (m3/min)

0 50 100 150 200 250 300 (CFM)

Ai風rfl量ow

564 CATALOG No. C1111B001 '21.2.IT

■ Dimensions (unit: mm)

M4×0.7,深55mm deep

Eアaーrthスg用roタunッdプtap

ROTATION

ø172±0.8 4-ø4.3
162±0.5
M取o付un用ti穴ng hole
AIRFLOW

(7.5) (7.5)

150±0.8 51±0.8

Rota回tin転g方di向rection Airfl風ow吹d出ir方ec向tion

■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)
Inlet side, Outlet side

148

162±0.3
2-R4.25 ø168

AC power supply 8.5 2-ø4.5 AC Fan ø172 mm AC

■ Wiring Diagram

AC



フFァANン

■ Options page: p. 586 Plug cord page: pp. 594 to 595

Finger guards Model no.: 489-1619-L10, 489-1619-L21, 489-084-L10,
Model no.: 109-319E, 109-319H, 109-320 489-084-L21

565CATALOG No. C1111B001 '21.2.IT

AC Fan Only standard fans (without sensors) have acquired CSA certification. Round type

ø172×51 mm

San Ace 172

■ General Specifications

· Material �������������� Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1)
· Expected life ������������ See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage)

Expected life at 40°C is for reference only.
· Motor structure ���������� Capacitor motor
· Motor protection function ������ Locked rotor burnout protection, Reverse polarity protection

For details, please refer to p. 599.
· Dielectric strength ��������� 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame)
· Dielectric strength (with sensor) ��� 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame)

50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame)
· Insulation resistance �������� 10 MΩ or more with a 500 VDC megger
· Sound pressure level (SPL) ����� At 1 m away from the air inlet
· Operating voltage range ������ Voltage of each model ±10%
· Storage temperature �������� -30 to +70˚C (Non-condensing)
· Sensor-Purpose lead wire ������ Brown Black Sensor Yellow
· Mass ��������������� 1000 g

■ Specifications
Standard

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109-311
109-314 100 50/60 27/25 0.33/0.25 0.65/0.64 147/196 0.59/0.787 47/51
109-312 115
109-313 200 0.29/0.22 0.55/0.54 2900/3500 5.3/6.4 187.3/226.1 -30 to +60 25000/60˚C
230 0.16/0.13 0.33/0.32 (56000/40˚C)

0.14/0.11 0.28/0.27

AC Fan ø172 mm AC with Sensor

For sensor specifications, please refer to p. 602. Sensor specification differs depending on the fan's speed specification.
For a 5 V sensor power supply (ITEM-20), please append "-20" to the end of model number. E.g. 109-371-20
For a 12 V sensor power supply (ITEM-30), please append "-30" to the end of model number. E.g. 109-371-30

Model no. Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life
[V] [Hz] [W] [A] [A] [min-1] [m³/min] [CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
109-371
109-374 100 50/60 27/25 0.33/0.25 0.65/0.64 147/196 0.59/0.787 47/51
109-372 115
109-373 200 0.29/0.22 0.55/0.54 2900/3500 5.3/6.4 187.3/226.1 -10 to +60 25000/60˚C
230 0.16/0.13 0.33/0.32 (56000/40˚C)

0.14/0.11 0.28/0.27

Note:These are Short LeadTime Service applicable models. Contact your point of sale for stock availability. For more information on the service, see p. 654.

■ Set Models

Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 655.

Order no. Fan Voltage Low-speed sensor Set items Finger guards Mounting screws

ST1-109-311 109-311 100 V ◯ (5 V) Plug cord* 109-319E M4×25 mm (4 screws)
ST1-109-314 109-314 115 V ◯ (12 V) 109-319E
ST1-109-312 109-312 200 V ◯ (5 V) 489-1619-L10 109-319E
ST1-109-313 109-313 230 V ◯ (12 V) 489-1619-L10 109-319E
ST1-109-371-20 109-371-20 100 V ◯ (5 V) 489-1619-L10 109-319E
ST1-109-371-30 109-371-30 ◯ (12 V) 489-1619-L10 109-319E
ST1-109-374-20 109-374-20 115 V ◯ (5 V) 489-1619-L10 109-319E
ST1-109-374-30 109-374-30 ◯ (12 V) 489-1619-L10 109-319E
ST1-109-372-20 109-372-20 200 V 489-1619-L10 109-319E
ST1-109-372-30 109-372-30 489-1619-L10 109-319E
ST1-109-373-20 109-373-20 230 V 489-1619-L10 109-319E
ST1-109-373-30 109-373-30 489-1619-L10 109-319E
489-1619-L10
489-1619-L10

* PSE compatible.

566 CATALOG No. C1111B001 '21.2.IT

■ Airflow - Static Pressure Characteristics

Standard with Sensor

109-311, 109-314, 109-312, 109-313 109-371, 109-374, 109-372, 109-373

Static静pr圧essure(inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V Static静pr圧essure(inch H2O) (Pa) 60 Hz 100 V/115 V/200 V/230 V
50 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V
0.8 200 0.8 200
0.6 150 0.6 150
0.4 100 0.4 100

0.2 50 0.2 50

00 2 4 6 8 (m3/min) 00 2 4 6 8 (m3/min)

0 50 100 150 200 250 300 (CFM) 0 50 100 150 200 250 300 (CFM)

Ai風rfl量ow Ai風rfl量ow

■ Dimensions (unit: mm) with Sensor
Standard
MM44××00..77,深55mm deep
M4×0.7,深55mm deep
Eアarーthスg用roタunッdプtap
アEaーrthスg用roタunッdプtap
ROTATION
ROTATION
10.8±0.4 10.8±0.4
7.5±0.4 7.5±0.4

AIRFLOW AIRFLOW

ø172±0.8 ø172±0.8
162±0.5 162±0.5

78 AC Fan ø172 mm AC

8-ø4.3 (7.5) (7.5) 300L 72 8-ø4.3 (7.5) (7.5)
Sensor-purpose
M取ou付n用tin穴g hole 51±0.8 lセeaンd サw用ireリード線 M取ou付nt用ing穴hole 51±0.8
L長eさng3t0h03L00L
Rotati回ng転d方ire向ction Airfl風ow吹出dir方ec向tion AWWGG2288 162±0.5 Airf風lo吹w 出di方re向ction
UL 1000077
Rota回tin転g 方di向rection

■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)

Inlet side, Outlet side
162±0.3

162±0.3
4-R4.25 ø168

8.5 4-ø4.5

567CATALOG No. C1111B001 '21.2.IT

AC power supply■ Wiring Diagram

Standard

A
C



フFァANン

with Sensor For sensor circuit 12 V (ITEM-30)
5 V (ITEM-20)
For fan power supply
AC power supply Sensor circuit Brown +4.5 to 5.5 V Sensor circuit Brown
AC +9.6 to 14.4 V

源 Yellow 100 mA max. Yellow 200 mA max.
+27.6 V max. +27.6 V max.
フFァANン Pull-up resistor Pull-up resistor
Sensor output
Black GND (0 V) Black Sensor output
GND (0 V)

GND (Black) should be shared in case that power supply for sensor circuit (Brown) and that for sensor pull-up (Yellow) are separated.

■ Options

Finger guards page: p. 586 Plug cord page: pp. 594 to 595

Model no.: 109-319E, 109-319H, 109-320, 109-1066, Model no.: 489-1619-L10, 489-1619-L21, 489-084-L10,
109-1068 489-084-L21

AC Fan ø172 mm AC

568 CATALOG No. C1111B001 '21.2.IT

569CATALOG No. C1111B001 '21.2.IT

San Ace Controller

■ Features Only the 9CT1-U001 model is cUL-certified.
Preventive maintenance of equipment (IoT functionality)

・Easy to connect to user's terminal devices. (Wireless LAN /
wired LAN)

・Enables users to monitor the status of fans and sensors from
remote terminal devices.

・Enables users to control the fan speed remotely via terminal
devices.

・Detects outlier sensor measurements and sends alerts.
・Saves the fan's cumulative operating time and other fan

measurement data to the cloud for later use.
・Prevents heat problems with user equipment, contributing

to reducing maintenance time and costs.

Low noise and high energy efficiency (Automatic control)

・Stores temperature, humidity, and air pressure measurements
for automatic fan speed control based on the setting
conditions.

・Makes fan cooling and ventilation more efficient, reducing
noise and improving efficiency.

Optimized fan settings (Manual control)

・Can connect and control a maximum of four fans, enabling
different speed settings for individual fans.

・Optimizes the airflow and static pressure of individual fans
in multi-fan systems.

■ Specifications

With wireless LAN Without wireless LAN With wireless LAN, cUL certified

Model no. 9CT1-001 9CT1-002 9CT1-U001(1)

Rated voltage [VDC] 12/24/48 12/24

Power consumption [W] 3.1(2)

Max. input power 970 W or less 64 W or less (At 12 VDC)
100 W or less (At 24 VDC)

San Ace Controller Operating voltage range [VDC] 7 to 60 7 to 27.6

Operating temperature range [˚C] -20 to +70

Control functions Manual / automatic

Control signal PWM signal
High-level voltage (VOH): 3.3/5 V
Frequency: 25 kHz

Monitoring criteria Fan speed, fan current, fan operation hours, sensor detection value, external input

No. of connectable fans Max. 4

Max. fan connection terminal 5A 5 A (At 12 VDC)
current (per terminal) 4 A (At 24 VDC)

Max. output current (Total) 20 A 5 A (At 12 VDC)
4 A (At 24 VDC)

No. of connectable sensors Max. 4

Compatible sensors(3) Temperature / humidity, air pressure, acceleration

External I/O functions Input Photocoupler-isolated input, ON: 15 to 28.8 VDC, OFF: 0 to 5 VDC

Output Photocoupler-isolated open-collector output, load voltage: 28.8 VDC or less,
output current: 0.1 A or less

Communication Wireless IEEE 802.11b/g/n, frequency: ― IEEE 802.11b/g/n, frequency:
2.4 GHz(4) 2.4 GHz(4)

Wired Ethernet 10BASE-T,100BASE-TX

Size [mm] 50 (W) × 135 (D) × 180 (H)

Mass [g] 450

Material Casing: Plastic

(1) Use a UL Class 2 power supply. (2) For use of this product alone, at 20˚C ambient temperature
(3) Use our dedicated sensors (options). (4) Available channels: Ch. 1 to 11

570 CATALOG No. C1111B001 '21.2.IT

■ Front View

External I/O connector Status LED
Fan connectors Power button
Reset button
DC power connector
LAN connector

microSD card slot

Sensor connectors A, B

■ System Configuration

Equipment

Controller (Cloud server) Terminal device

External
input/output

Fans

Wireless Internet
communication

Settings, control, LAN San Ace Controller
monitoring PC
Data, alarm
DC power supply
Sensors

571CATALOG No. C1111B001 '21.2.IT

■ Graphical User Interface (GUI) Screens
Settings, control, monitoring, and data download can be done through web browsers.

Sample screens Measurement data

Control settings

Graphs Alarms

■ Dimensions (unit: mm)

San Ace Controller 4-ø8.5±0.3 135±1
4-ø4.5±0.3 121±0.5 50±1
166±0.5
180±1

572 CATALOG No. C1111B001 '21.2.IT

■ Options

• Sensors

Sensor type Temperature / Air pressure sensor Accelerometer
Humidity sensor
9CT1-A
Model no. 9CT1-T 9CT1-P Acceleration: 0 to
60 m/s2 (2)
Measurement range Temperature: -20 to +70˚C Air pressure: 800 to
Humidity: 20 to 85% RH(1) 1100 hPa

Operating temperature -20 to +70
range [˚C]

Operating humidity 20 to 85(1)
range [% RH]

Size [mm] 53 (W)× 46 (D)× 22 (H)

Mass [g] 35

Material Casing: Plastic

(1) Non-condensing (2) Total acceleration from three axes

• Dimensions (unit: mm)

4-3.5±0.3 53±0.5
4-7.2±0.3 44±0.5

46±0.5
37±0.5

22±0.5

San Ace Controller

573CATALOG No. C1111B001 '21.2.IT

PWM Controller Box type

■ Features PCB type
Reduces system power consumption and fan noise

For PWM fan speed control, a PWM control circuit needs to be
newly designed and configured.
By using this product, however, PWM control function fans can
be fully utilized without the need for preparing new circuits,
contributing to reducing the system power consumption and
the fan noise.

Can be common-powered by the fan power supply

The controller can be powered by the fan power supply of
rated voltage 12, 24, and 48 VDC, and no separate supply is
required.

Maximum of four fans connectable

Up to four fans with PWM control function can be connected
and controlled.

■ Specifications

Box type

Model no. 9PC8666X-S001 9PC8666X-S101

Size [mm] 86 (H)× 66 (W)× 38 (D)

Rated voltage [V] 12/24/48

Power consumption [W] 0.2(1)

Operating temperature [˚C] -20 to +70

Input Input voltage range [V] (V+, V-) 7 to 60

terminal Control voltage range [V] 0 to 5.5

Output PWM signal output VOH (high level voltage): 3.3 or 5 VDC selectable
terminal PWM frequency [kHz] 25 1

Output current 20 mA max. (total sum of 4 terminals)

Output breakdown voltage [V] 6.5

No. of connectable fans Up to 4 fans

Control functions(2) Voltage control, Internal adjustment (variable resistor) control,

External adjustment (variable resistor) control(3),Thermistor control(3)

Mounting method DIN rail mounting or screw mounting

Mass [g] 110

Material Case: Plastic

PWM Controller PCB type

Model no. 9PC8045D-V001 9PC8045D-R001 9PC8045D-T001 9PC8045D-V101 9PC8045D-R101 9PC8045D-T101

Size [mm] 80 (H)× 45 (W)× 17 (D)

Rated voltage [V] 12/24/48

Power consumption [W] 0.2(1)

Operating temperature [˚C] -20 to +70

Input Input voltage range [V] (V+, V-) 7 to 60

terminal Control voltage range [V] 0 to 5.5

Output PWM signal output VOH (high level voltage): 3.3 or 5 VDC selectable
terminal PWM frequency [kHz] 25 1

Output current 20 mA max. (total sum of 4 terminals)

Output breakdown voltage [V] 6.5

No. of connectable fans Up to 4 fans

Control functions Voltage control Variable resistor Thermistor Voltage control Variable resistor Thermistor

control(3) control(3) control(3) control(3)

Mounting method Screw mounting

Mass [g] 27

Material PCB: FR-4

(1) When output terminals are turned on. (2) Control functions are mutually exclusive for Box type.
(3) Variable resistor and thermistor are not supplied with the controller and need to be prepared separately.
Note: Be noted that if applied input voltage or frequency is out of range of the connected fan, how the fan speed responds to the PWM duty cycle may be altered.

574 CATALOG No. C1111B001 '21.2.IT

■ Front View (component names) Thermistor conサnーecミtiスonタte接rm続i端na子ls • PCB type

• Box type T温e度m設pe定raスtuイreッsチelector switch
((fサorーthミerスmタisコtoンr cトoロntーroルl mのoみde)l only)
Gグroラuウndンtドer端m子inal
P電o源we入r力su端p子ply input terminal Variable resistor I入np力ut端te子rminals
Control voltage ground or conn可ec変tio抵n抗te接rm続i端na子ls PPWWMM s信ig号na出l 力ou端tp子ut terminals
vコarンiaトblロe ーreルsis電to圧r グラウンド, Control function機s能el切ec替toスr イswッitチch
cまonたnはec可tio変n抵te抗rm接i続na端l 子 P出W力MPoWuMtpu電t 圧voltage
Control voltage PWM output voltage VVOOHHs切e替lecスtoイr ッswチitch
inコpンutトteロrmーiルna電l 圧入力端子 出力 PWM 電V圧OHVsOeHl切ec替toスr sイwッitcチh

A調d整juつstmまeみnt knob PWM signaPlWoMutp信u号t t出er力m端ina子ls

■ Connection Examples and PWM Signal Output Characteristics

Controller can be common-powered by the power supply for 12, 24, and 48 VDC rated voltage fans.
It can also be powered by a separate supply as long as both supplies share the same ground.

Voltage control *Ensure that the input voltage does not exceed 5.5 VDC.

Output duty cycle controlled with input voltage of 0 to 5 VDC.

• Box type

DC power supply
+ GND

Control voltage Control Voltage -
+ GND Output Duty Cycle Characteristics

(%)
100

80

Output duty cycle60

PWM signal 40 PWM Controller
20
• PCB type (Model no.: 9PC8045D-V001)

0 1 2 3 4 5 (VDC)
Control voltage

+ GND + GND PWM signal

DC power supply Control voltage

575CATALOG No. C1111B001 '21.2.IT

Internal adjustment (variable resistor) control Inner Scale Reading -
Output duty cycle controlled with the adjustment knob. Output Duty Cycle Characteristics

• Box type (%)
100
DC power supply
+ GND

75

Output duty cycle 50

PWM signal 25

Output duty cycle controlled 0 25 50 75 100 (%)
with the adjustment knob (on the inner scale) Inner scale reading with adjustment knob

PWM Controller

External adjustment (variable resistor) control

Output duty cycle controlled with variable resistor connected to terminals.

• Box type DC power supply
+ GND

Resistance -
Output Duty Cycle Characteristics

Variable resistor Recommended total resistance: 10 kΩ
Resistance taper: B (linear curve tting)

(%)
100

80

PWM Controller Output duty cycle 60

PWM signal 40
20
• PCB type (Model no.: 9PC8045D-R001)

0 1 2 3 4 5 6 7 8 9 10 (kΩ)
Resistance

+ GND PWM signal
DC power supply Variable resistor

576 CATALOG No. C1111B001 '21.2.IT

Thermistor control

Automation control of output duty cycle in response to the temperature detected with an external thermistor.

• Box type DC power supply
+ GND

Controlling Conditions

Thermistor TST: Temperature set with the adjustment knob (30 to 50°C)
TTH: Temperature detected with thermistor

Recommended thermistor conditions
Type: NTC
R25 (Resistance at 25°C): 10 kΩ
B value: B25/85 = 3435 K

Target temperature Temperature Duty cycle Fan rotational speed
can be set with the conditions Increases
adjustment knob TST <TTH Decreases (For reference)
(on the outer scale) TST >TTH Maintained
TST ~~ TTH Increases
Decreases
Maintained

PWM signal

• PCB type (Model no.: 9PC8045D-T001)

Target temperature selected
with switch

+ GND PWM signal
DC power supply
Thermistor

■ Dimensions (unit: mm)

• Box type Fro正nt面view Side側v面iew Bac裏k面view
((3939m以a下x.))
4-ø3.5±0.3 66±1
M取o付u用nt穴ing hole 57±0.5

DDIINNレraーil ルba取se付s位ec置tion

86±1 PWM Controller
77±0.5
35.5±0.5

25±0.5 (4) DIN rail clip
36±1 Sid側e面view
• PCB type Fro正nt面view
80±0.5 Temperature setting 13 max.
70±0.3 selector switch 2.5 max.
(Only for model no.: 9PC8045D-T001)
45±0.5 5 67 12 3 (1.6)
39±0.3 0
4 577CATALOG No. C1111B001 '21.2.IT
ON PWM output voltage
VOH selector switch

4-ø3.5±0.3

Airflow Tester

■ Features (Patented as a movable measurement device for
measuring device airflow and system impedance)

Enables the selection of the optimal fan for a device

An optimal fan for a device can be selected by entering
accurate measurement results into thermal design
simulation software.

Compact and lightweight

With a compact design and weight of approximately 6 kg, it is
portable enough to measure immobile equipment.

■ Measurement Functions

・System Impedance Measurement of the resistance to the
flow of air within a device

・Operating Airflow Measurement of the actual airflow that
passes through a device when a fan is
mounted With connection duct mounted

・P-Q Performance Measurement of airflow versus static
pressure characteristics*

* Performance curve that illustrates the characteristics of a fan for use within
a certain system.
It shows the relationship between airflow and static pressure.

■ Specifications

Model no. 9AT2560S-000□(1) 9AT2560A-000□(1) 9AT2560C-000□(1)

Measurement Airflow m3/min CFM CFM
units Static pressure Pa
Measurement Airflow Pa inchH2O 7 to 282 CFM
range Static pressure 0.20 to 8.00 m3/min 7 to 282 CFM 0 to 1000 Pa
Measurement Airflow
accuracy Static pressure 0 to 1000 Pa 0 to 4.01 inchH2O

Operating Ambient ±7% of maximum measurable airflow with each nozzle
environment temperature
±10 Pa (0.04 inchH2O) for measurement results < 200 Pa,
±50 Pa (0.20 inchH2O) for measurement results ≥ 200 Pa
0 to 40˚C

Humidity 20 to 85% RH (non-condensing)

Display Data no., Measurement values (airflow, static pressure(2)), Measurement status,
Nozzle selection, Measurement mode selection

Interface Digital output: Included USB serial adapter

Power supply Input voltage 100 to 240 VAC,50/60 Hz

Power 260 VA max.
consumption

Airflow Tester Dimensions 600 (W)× 250 (H)× 250 (D) mm

Mass Main unit: Approx. 6 kg, Connection duct (including board holder): Approx. 1.5 kg

Included peripherals 1 Set of measurement nozzles, Plastic mounting board (5 pcs / set), Connection duct,
AC power cable (2.5 m), USB serial adapter, Instruction manual, Quick start guide, Data
viewer software

(1) The AC power plug shape differs with the number in □ of model numbers.
AC power plug included in models with 1 in □ is for Japan and North America regions (2 parallel flat pins + a round grounding pin), Input voltage: 100/120 VAC,
50/60 Hz
AC power plug included in models with 2 in □ is for Europe region (2 round pins + a female grounding contact), Input voltage: 220 VAC, 50 Hz
AC power plug included in models with 3 in □ is for China region (2 angled flat pins + a flat grounding pin), Input voltage: 220 VAC, 50 Hz
Product also available without an AC power cable. Model no. 9AT2560S-0000, 9AT2560A-0000, 9AT2560C-0000

(2) Static pressure values are calculated with standard atmosphere as 1013 hPa at 20˚C.

578 CATALOG No. C1111B001 '21.2.IT

■ Airflow Tester Part Names

T上op面view

↓↓SiBde側v面iew B C持a運rrびyiハngンhドaルndle

Con操tr作olパpネanルel ↑↑SiAde側v面iew A

F前ro面n(t v吸ie込w口(a)ir inlet side) SAid側e面view A SPeCrイiaンl pタoフrtェース B背ac面k(v吐ie出w口(a)ir outlet side)

P主o電we源r switch
AACC 電so源ck入e力t

A空ir気in取le込t 口 測M定o機de能s切e替leバctiルoブn valves Aux補ili助arフy ァfaンn

SBid側e面view B

ノNズoルzz交le換s部lot

Co操n作troパl pネanルe(l (拡zo大om図e)d in) A風irf量low Static静p圧ressure

デDaーtaタNNoo. .

Airflow Tester

S状ta態tu表s示indicator

Nノoズzzルle選se択leボctタioンn Sスtaタrtー/Sトto/p
button bスuトttoッnプボタン

Mモoーdドe s選el択ecボtioタnン
button

Mode seモleーctiドon選i択nd表ic示ator Nノoズzzルle選se択le表ct示ion indicator

579CATALOG No. C1111B001 '21.2.IT

Airflow Tester

■ Usage Examples

Cut out a hole in the mounting board matching the vent opening of the device to be measured, and place the mounting board
firmly against the device to perform measurements.

D測ev定ice物to be measured

D測ev定ic物e to be measured

V通en風t 孔

接Co続nnダecクtioトn V通en風t 孔

duct

P樹la脂sti取c 付板

mounting
board

■ Data Viewer Software (included)
Obtained measurement data can be represented as a graph and saved on a PC.

Screen examples P-Q performance shown below based on catalog data.

Airflow Tester ■ Option

Carrying case Measurement nozzle case included Plastic mounting boards 

Model no. 9AT2560-B001 Sized to fit the duct frame. Five boards included with AirflowTester.
Please add "CS" to the end of the model no.
of AirflowTester in page 1 when ordering Model no. 9AT2560-P001
AirflowTester and carrying case as a set. Quantity 5 pcs / set
e.g. 9AT2560S-0001CS Dimensions 525 (W)× 275 (H)× 4 (D) mm

Dimensions 705 (W)× 385 (H)× 415 (D) mm

Carrying case, measurement nozzle case Plastic mounting boards (5 pcs)

580 CATALOG No. C1111B001 '21.2.IT

■ Dimensions (unit: mm)

• Main unit

T上op面view ↓↓SiBde側v面iew B

F前ro面nt(vi吸ew込(口air)inlet side) SAid側e v面iew A ↑↑SiAde側v面iew A A風irf吹lo出w方di向rection
600
170 B背ac面k(vie吐w出(a口ir)outlet side)
140 220
186

170 B下ot面tom view U1/N4-C201U/4N"-C20ネsジcrew
140 SBid側e v面iew B
302
• Connection duct 250552
177500
186273
250

Airflow Tester

177

581CATALOG No. C1111B001 '21.2.IT

Option Options

Cooling Fan Units Customized Products

Features
We provide assembled fan units in accordance with the specification or requirements of the equipment.
For use in communications equipment, servers, storage systems.

■Example

Electrolytic Corrosion Proof Fans Customized Products → p. 606

Features
This cooling fan prevents electrolytic corrosion of bearings even under conditions where electromagnetic noise is generated.
Electrolytic corrosion of ball bearings is prevented by using ceramic balls in ball bearings. The ceramic material is an insulating material.
Manufacturable to meet specifications of all San Ace series fans.

582 CATALOG No. C1111B001 '21.2.IT

Finger guards List
Increases safety by preventing foreign objects from entering fans. Fans can be used with little effect on airflow and static pressure.

Size Model no. Mounting side Surface treatment

Nickel-chrome plating (silver) Cation electropainting (black)

36 mm sq. type 109-1050 Inlet side, Outlet side ✓ -
38 mm sq. type 109-1065
40 mm sq. type 109-059 Inlet side, Outlet side ✓ -
109-059H
✓ -
Inlet side, Outlet side ✓



52 mm sq. type 109-149E Inlet side, Outlet side ✓ -
109-149
Outlet side ✓ -

60 mm sq. type 109-139E ✓ -
109-139H Inlet side, Outlet side ✓
70 mm sq. type, ø70 mm type 109-1128
80 mm sq. type 109-049E -
109-049H
Inlet side, Outlet side ✓ -

✓ -
Inlet side, Outlet side ✓



109-049C Outlet side ✓ -

92 mm sq. type 109-099C Outlet side ✓ -
ø92 mm type 109-1147
92 mm sq. type, ø100 mm type 109-099E Impeller side, Nameplate side ✓ -
109-099H
✓ -
Inlet side, Outlet side ✓



120 mm sq. type 109-019E ✓ -
109-019K Inlet side, Outlet side ✓



109-019C Outlet side ✓ -
- ✓
109-019H
127 mm sq. type, ø175 mm type 109-722 Inlet side, Outlet side ✓ -
109-722H
Inlet side, Outlet side - ✓

127 mm sq. type 109-723 Outlet side ✓ -
ø133 mm type 109-1112
ø136 mm type 109-1139 Inlet side ✓ -
140 mm sq. type 109-719
109-719H Impeller side, Nameplate side ✓ -

✓ -
Inlet side, Outlet side ✓



150 mm sq. type 109-1051 Inlet side, Outlet side ✓ -
ø150 mm type 109-1052
109-1104 Outlet side ✓ -
109-1104H
Inlet side ✓ -
- ✓

160 mm sq. type 109-619E ✓ -
109-619H Inlet side, Outlet side ✓



109-620 Outlet side ✓ -
109-319J
ø172 mm Sidecut type 109-319E Inlet side, Outlet side ✓ -
ø172 mm Sidecut, Round type 109-319H
✓ -
Inlet side, Outlet side ✓



109-320 Outlet side ✓ -
109-1066
ø172 mm Round type 109-1068 Inlet side, Outlet side ✓ - Option
ø200 mm type 109-1102*
109-1102H* Outlet side ✓ -

✓ -
Inlet side, Outlet side ✓



109-1103* Outlet side ✓ -
- ✓
109-1103H*

109-720 ✓ -
Inlet side, Outlet side ✓
109-720H


109-721 Outlet side ✓ -
- ✓
109-721H
ø221 mm type 109-1138 Inlet side ✓ -
ø225 mm type 109-1138H - ✓
109-1137
109-1137H Inlet side ✓ -
- ✓

270 mm sq. type 109-1146 Inlet side ✓ -
(for Bracket-mounted Centrifugal Fan) 109-1146H - ✓

* Applicable model no.: 9GV20*

583CATALOG No. C1111B001 '21.2.IT

Options

Finger guards Dimensions (unit: mm)
For use in environments subject to water splashes, cation electroplating models are recommended.

36 mm sq. type 38 mm sq. type 40 mm sq. type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-1050 Nickel-chrome plating (silver) 4 109-1065 Nickel-chrome plating (silver) 5 109-059 Nickel-chrome plating (silver) 7
109-059H Cation electropainting (black)

Inlet side, Outlet side Inlet side, Outlet side Inlet side, Outlet side

4-ø4 +00.3 4.8 +1 4-ø4±0.3 4.8±0.5 3.5±0.3 4 +10
0 ø1.6

ø1.6 ø28.5
29.5±0.5

32

30±0.5

34
49 -+01..55
38.5
ø1.6 ø1.6 ø1.6ø29.5

ø1.6 ø26 ø18.3
ø45.3

ø17.5
30±0.5

ø15
29.5±0.5

52 mm sq. type 60 mm sq. type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-149E Nickel-chrome plating (silver) 9 109-149 Nickel-chrome plating (silver) 7 109-139E Nickel-chrome plating (silver) 14.5
109-139H Cation electropainting (black)

Inlet side, Outlet side Outlet side Inlet side, Outlet side

3.7±0.3 4 +01 3.7±0.3 4 +01 4.3±0.3 4 +10
ø1.6 ø1.6
ø1.6 ø1.6 ø43.8
ø43.8 ø1.6 ø53 ø1.6

63.2 -+01..55
53.3

63.2 -+01..55
53.3

75 -+01..55
62
ø32.6

ø59.4 ø59.4 ø70.7

70 mm sq. type, ø70 mm type 80 mm sq. type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-1128 Nickel-chrome plating (silver) 17 109-049E Nickel-chrome plating (silver) 21 109-049C Nickel-chrome plating (silver) 17
109-049H Cation electropainting (black)

Inlet side, Outlet side Inlet side, Outlet side Outlet side

4.3±0.3 5 +10 4.3±0.3 5 +10 4.3±0.3 5 +10
ø1.6
ø63.2 ø1.6 ø16 ø75 ø1.6 ø1.6 ø75
ø1.6 ø1.6

Option 78 88 +1.5 99 88
105 -+01..55 -0.5
+1.591
-0.5 105 ø39.6

(ø87) ø101.2 ø101.2

92 mm sq. type ø92 mm type 92 mm sq., ø100 mm type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-099C Nickel-chrome plating (silver) 22 109-1147 Nickel-chrome plating (silver) 23 109-099E Nickel-chrome plating (silver) 29
109-099H Cation electropainting (black)

Outlet side Impeller side, Nameplate side Inlet side, Outlet side

4.3±0.3 5 +10 3.5±0.5 (ø85) 4.3±0.3 5 +10
ø1.6 ø1ø.63ø9.887 ø1.6ø1.6
3.5±0.3 ø77.6 ø1.6
ø1.6 ø87

120.5 -+01..55 99 3.5±0.5 +1.5
88.8±0.5 -0.5

75 120.5

ø116.6 ø18.6 ø16.2
ø1.6
4 +10 ø116.6

584 CATALOG No. C1111B001 '21.2.IT

Finger guards Dimensions (unit: mm)
For use in environments subject to water splashes, cation electroplating models are recommended.

120 mm sq. type 127 mm sq., ø175 mm type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-019E Nickel-chrome plating (silver) 42 109-019C Nickel-chrome plating (silver) 32 109-722 Nickel-chrome plating (silver) 43
109-019K Cation electropainting (black) 109-019H Cation electropainting (black) 109-722H Cation electropainting (black)

Inlet side, Outlet side 5 +01 ø148 Outlet side 5 +01 Inlet side, Outlet side
ø118
ø1.6ø1.ø6113 ø1.6 ø1.6 ø1.6 ø1.6
ø113
152.5±0.5 ø42.2
4.3±0.3
ø18.6

130

4.3±0.3

130

165±0.5
ø119

4.3 +-00..24

ø24.6

142
5 -01
ø148 ø160.5
152.5 +1.5
-0.5

127 mm sq. type ø133 mm type ø136 mm type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-723 Nickel-chrome plating (silver) 34 109-1112 Nickel-chrome plating (silver) 65 109-1139 Nickel-chrome plating (silver) 41

Outlet side Inlet side 3.2±1 Impeller side, Nameplate side

3.2 -01 4.3±0.3 ø1.6
ø1.6 ø1ø.6108.4
ø1.6 ø1.6 ø1.6
ø1(1ø960)
ø87
165±0.5
4.3±0.2

123.1±1
133±2

3.5±0.3 ø16
120
ø16
(ø128) 5 +1
ø160.5 0

140 mm sq. type 150 mm sq. type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-719 Nickel-chrome plating (silver) 51 109-1051 Nickel-chrome plating (silver) 63 109-1052 Nickel-chrome plating (silver) 53
109-719H Cation electropainting (black)

Inlet side, Outlet side Inlet side, Outlet side Outlet side

ø1ø816+70-6.15 4.3 +-00..24 5.5 -10 øø129001.+9-01.5 4.3 +0.4 5.5 -10 ø1.6 ø190.9 3.2 0
-0.2 -1

ø1.6 ø1.6 4.3±0.2

4-12 4-12 197.7±0.5
Option
ø145 ø156

4-4.5 ø26.8 4-4.5 (ø62.2)
ø1.6 ø1.6
ø1.6 ø1ø3266.2.8 ø143.8 ø143.8

ø150 mm type 160 mm sq. type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-1104 Nickel-chrome plating (silver) 31 109-619E Nickel-chrome plating (silver) 85 109-620 Nickel-chrome plating (silver) 74
109-1104H Cation electropainting (black) 109-619H Cation electropainting (black)

Inlet side Inlet side, Outlet side Outlet side

ø136.2 +2 ø128.7 5.5 -01 ø205.2ø+-011.95ø51.599.7 ø205.2ø+10-1.95ø51.599.7
-1
5.5 +-00..24 8 -10.5 5.5 +-00..24
4.3 +0.4 3.6 -01.5
ø1.6 -0.2 ø26.3 ø1.8 ø1.8
ø1.8
ø111.5 ø1.8 ø61.7

ø97.6 ø184
ø1.6

585CATALOG No. C1111B001 '21.2.IT

Options

Finger guards Dimensions (unit: mm)
For use in environments subject to water splashes, cation electroplating models are recommended.

ø172 mm Sidecut type

Model no. Surface treatment Mass (g) Applicable model no. Finger guard 109-319J should be mounted with four holes
9HV57*/9SG57*/9GV57* as in the drawing.
109-319J Nickel-chrome plating (silver) 65 9CR57*/9WG57*
Hexagonal nuts

Inlet side, Outlet side Finger guards

ø172 +0.5 ø162 4.3 +0.4 5.5 0 Plain
-1 -0.2 -1 washers
Spring
ø1.6 ø1.6 washers

ø147 Screws

ø152

55.5° 71.3±1 Fan
71.3±1 No nuts or screws for use in attachment included.

ø172 mm Sidecut, Round type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Finger guards 109-319E, 109-319H, and 109-320
should be mounted with two holes as in the
109-319E Nickel-chrome plating (silver) 69 109-320 Nickel-chrome plating (silver) 53 drawing and do not use any other holes.
109-319H Cation electropainting (black)

Inlet side, Outlet side Outlet side

øø114.68 øø161722+0-1.5 4.3 +0.4 9.5 -01 4ø.31.+6-00..24 ø1.6 3.2 -01 Hexagonal nuts
-0.2 ø62.2
Finger guards
ø1.6 Plain washers
Spring washers
ø152
Screws

ø148 Fan
ø172 +-01.5
ø162

No nuts or screws for use in attachment included.

ø172 mm Round type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

Option 109-1066 Nickel-chrome plating (silver) 61 109-1068 Nickel-chrome plating (silver) 54

Inlet side, Outlet side Outlet side

ø162 4.3 +-00..24 9.5 -01 ø162 4.3 +-00..24 3.2 -01
ø172+-10.5 ø172+-10.5
ø1.6 ø1.6 ø1.6
ø148 ø1.6 ø62.2
ø148

ø152

586 CATALOG No. C1111B001 '21.2.IT

Finger guards Dimensions (unit: mm)
For use in environments subject to water splashes, cation electroplating models are recommended.

ø200 mm type

Model no. Surface treatment Mass (g) Applicable model no. Model no. Surface treatment Mass (g) Applicable model no.
9GV20* 9GV20*
109-1102 Nickel-chrome plating (silver) 100 109-1103 Nickel-chrome plating (silver) 80
109-1102H Cation electropainting (black) 109-1103H Cation electropainting (black)

Inlet side, Outlet side Outlet side

4.3 +0.4
-0.2
ø208ø189.8ø1.69.5 +-109.5+0ø2000-14.3+0.43.2+-01
199+1-0.5 A -1 ø1.6 ø1.6 -0.2
B
ø1.6
øø210882.8

214.1+-10.5 (ø92.2)
(196.3)
214.1+-10.5

B Sec断ti面onAAAA Se断ct面ioBnB BB
A

ø200 mm type

Model no. Surface treatment Mass (g) Applicable model no. Model no. Surface treatment Mass (g) Applicable model no.
109E20* 109E20*
109-720 Nickel-chrome plating (silver) 84 9EC20* 109-721 Nickel-chrome plating (silver) 66 9EC20*
109-720H Cation electropainting (black) 109-721H Cation electropainting (black)

Inlet side, Outlet side Outlet side
4.3 +-00..24
4.3 +-00..42 3.2 -10
ø1.6
ø1.6
ø1ø8817.488 -10
øø118781.4

ø1.6 ø1.6

+1 ø178 +1
-0.5 -0.5

194.5 194.5

ø221 mm type ø225 mm type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-1138 Nickel-chrome plating (silver) 105 109-1137 Nickel-chrome plating (silver) 94
109-1138H Cation electropainting (black) 109-1137H Cation electropainting (black)

Inlet side Inlet side Option
+0.4
4.3±0.3
4.3 - 0.2 A
ø1.6
ø1.6
205.9±1.5 ø245 ø1.6+1 ø1.6 Bø186.9
250.8 - 0.5 ø1.6 ø213ø.1380.2
ø26.8 210.6±1.5 ø26.8
ø192
194.4±1 217.6±1
ø194.1

ø1.6 B A 5±0.5 3.2 +-10
0
Se断ct面ioAnAAA Se断ct面ioBnBBB
5.5-1

587CATALOG No. C1111B001 '21.2.IT

Options

Finger guards Dimensions (unit: mm)
For use in environments subject to water splashes, cation electroplating models are recommended.

270 mm sq. type (for Bracket-mounted Centrifugal Fan)

Model no. Surface treatment Mass (g) Finger guard 109-1146 and 109-1146H should be mounted with four holes
as in the drawing.
109-1146 Nickel-chrome plating (silver) 106
109-1146H Cation electropainting (black)

Inlet side Fフinィgンerガgーuaガrdード
Sネcrジews
5.3±0.3
ø2 A

194.4±1
ø186.9
311±1
ø194.1
ø1.6 B
øø261..86
øø310850..72

+0.5 +0
3.6 -1 3.2-1

B

Se断ct面ionBBBB

A 5±1 Fフaァn ン
Se断ct面ionAAAA No nuts or screws for use in attachment included.

Mounting example Hexagonal nuts Centrifugal fan
Fan
Axial fan Fan
Hexagonal nuts
Finger guard
Plain washers Inlet nozzle
Spring washers Finger guard
Screws
Plain washers
Spring washers
Screws

Chassis

No nuts or screws for use in attachment included.

Option

588 CATALOG No. C1111B001 '21.2.IT

Inlet nozzle for centrifugal fan and splash proof centrifugal fan Dimensions (unit: mm)

Nozzle mounted in fan inlet side to adjust the flow of introduced air. Material: Steel sheet
For use in environments subject to water splashes, cation electroplating models are recommended.

ø70 mm type ø100 mm type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)
109-1106 Electro nickel plating (silver) 40 109-1080 Electro nickel plating (silver) 80
109-1080H Cation electropainting (black)

ø87±ø09.85±1 90°±1°(Each) 3±1 ø56±0.5 ø70±0.55±1
(1)
4-ø4.5±0.5 90°±1(°(E等a配ch)) 4-ø4.3±0.5 (1)
(R2.8) ø116ø.61±208.±51
(R4.8)

ø133 mm type Surface treatment Mass (g) ø150 mm type Surface treatment Mass (g)
Electro nickel plating (silver) 76 Electro nickel plating (silver) 70
Model no. Cation electropainting (black) Model no. Cation electropainting (black)
109-1069 109-1081
109-1069H 109-1081H

ø85±0.513±1 ø100±0.57±1
(1)
(Each) 90°±1(°(E等a配ch)) 4-ø4.5±0.5 (1)
ø1ø1182±90±.51 ø12ø81±309±.51 (R6)
90°±1(° 等配



4-ø4.5±0.5

ø175 mm type Surface treatment Mass (g) ø221 mm type Surface treatment Mass (g)
Electro nickel plating (silver) 100 Electro nickel plating (silver) 230
Model no. Cation electropainting (black) Model no. Cation electropainting (black)
109-1073 109-1135
109-1073H 14±1 109-1135H

(1) 6-ø5.5±0.5 ø155.2±0.5
ø242±0.5
(R10)
ø126±0.5 ø252±1 45°±1° 4-ø4.3±0.5 21±1 118±1
(0.8)
90°±1(°(E等a配ch)) 4-ø4.5±0.5 ((E等6a0c配°h±))1° (R22)
øø115780±±01.5
ø245±0.5 90°±1°((E等ac配h))

Option

ø225 mm type Surface treatment Mass (g)
Electro nickel plating (silver) 360
Model no. Cation electropainting (black)
109-1134
109-1134H

ø210ø±202.35±1 90°±1(°(E等ac配h)) 29.5±1 ø146±0.5
(1.5)

4-4.5±0.5 (R24)

589CATALOG No. C1111B001 '21.2.IT

Options

EMC guards Dimensions (unit: mm)

It is a metallic piece that protects materials from the adverse effects of electromagnetic noise sources. It provides electromagnetic shielding.
It is attached to the casing of a device by means of the fan fixing screw (s). Ground the devices equipped with an EMC guard.
Rust may occur if used in wet environments. Please refer to page 606 for detail.

80 mm sq. type 80 mm sq. type 92 mm sq. type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-1038 Nickel-chrome plating (silver) 14 109-1039 Nickel-chrome plating (silver) 10 109-1040 Nickel-chrome plating (silver) 15

Representative fans Dimensions of fans Representative fans Dimensions of fans Representative fans Dimensions of fans
model numbers (mm) model numbers (mm) model numbers (mm)
109P08* 109P08* 9G09*
9GV08* 80 × 80 × 20 9GA08* 80 × 80 × 15 9G09* 92 × 92 × 32
9GV08* 80 × 80 × 25 109R08* 80 × 80 × 20 9GV09*
9HV08* 9A08* 9GA09* 92 × 92 × 38
9HVA08* 80 × 80 × 38 9GA08* 80 × 80 × 25 9AD09*
9HVB08* 9GA08*
80 × 80 × 32
9G08* 80 × 80 × 38
9GA08*

4.3±0.3 5 +1 4.3±0.3 5 +1 4.3±0.3 5 +1
ø1.6 0 ø1.6 0 ø1.6 0

ø43 ø31
10 5 -+01..55 ø43
88

10 5 -+01..55
88

120.5-+01..55
99

ø116.6
ø101.2
ø101.2

120 mm sq. type ø172 mm type

Model no. Surface treatment Mass (g) Model no. Surface treatment Mass (g)

109-1037 Nickel-chrome plating (silver) 26 109-1036 Nickel-chrome plating (silver) 49

Representative fans Dimensions of fans Representative fans Dimensions of fans
model numbers (mm) model numbers (mm)
9G12* 109E47*
9GV12* 120 × 120 × 25 109L17* ø172 × 25
9GL12* 9GV57* ø172 × 51
9G12* 120 × 120 × 38 109E17*
9GV12* 109E57*
9HV12* 9SG57*
9LG12*
9AD12*

4.3±0.3 ø1625+1ø172+-10.54 . 3+- 00..24 9.5+-10
ø1.6 ø148 0
ø1.6
Option
ø57.2
152.5±0.5

130

ø72
ø152

EMC guard attached to a cooling fan

590 CATALOG No. C1111B001 '21.2.IT

Resin finger guards Dimensions (unit: mm)
Material Frame: Resin (PPE+PS) UL file no. E82268 94V-0

60 mm sq. type Mass (g) 80 mm sq. type Mass (g)
7 10
Model no. Model no.
109-1003G 109-1002G

60.5±1 6.5±0.5 4-ø4.3±0.3 82±1 7±0.5 4-ø4.3±0.3
50±0.3 4-2±0.5 71.5±0.3 4-2±0.5

60.5±1 82±1
50±0.3 71.5±0.3

92 mm sq. type Mass (g) 120 mm sq. type Mass (g)
12 23
Model no. Model no.
109-1001G 7±0.5 4-ø4.3±0.3 109-1000G 7±0.5 4-ø4.3±0.3
4-2±0.5 4-2±0.5
92±1 119±1
82.5±0.3 104.8±0.3

92±1 119±1
82.5±0.3 104.8±0.3

Airflow - Static pressure characteristics Mounting example

Measured with our double chamber measuring device Hexagonal nuts (4)
(120 mm sq. type)
Fan
Static pressure (Pa) Fan unit Chassis
160 (9G1212G101) Finger guard
140 Small pan-head screws (4)
120 With resin nger guard
100 (109-1000G) equipped*

80
60
40
20

0 1 2 3 4 5 (m3/min) Option

Air ow

Applied voltage: 12 VDC
* Finger guard is attached on air inlet side of fan.

Operating temperature limit is between -20 to +70˚C. (non condensing)
Plastic finger guards are placed on both the intake and exhaust sides of the fan.
No nuts or screws for use in attachment included.

591CATALOG No. C1111B001 '21.2.IT

Options

Resin filter kits Dimensions (unit: mm)

Material Guard, cover: Resin (PPE+PS) UL file no. E82268 94V-0 Filter: Polyurethane foam UL file no. E74916 (S) 94HF-1
PPI: Particles Per Inch Indicates the number of holes per inch. Note that the higher the number, the finer the grain of the sponge.

60 mm sq. type Mass (g) 80 mm sq. type Mass (g)
11 19
Model no. Model no.
109-1003F13 (13 PPI) Quantity 109-1002F13 (13 PPI) Quantity
109-1003F20 (20 PPI) 5 109-1002F20 (20 PPI) 5
109-1003F30 (30 PPI) 109-1002F30 (30 PPI)
109-1003F40 (40 PPI) 9.5±0.5 4-ø4.3±0.3 109-1002F40 (40 PPI) 10.5±0.5 4-ø4.3±0.3

Replacement filter model no. Replacement filter model no.
109-1003M13 (13 PPI) 109-1002M13 (13 PPI)
109-1003M20 (20 PPI) 109-1002M20 (20 PPI)
109-1003M30 (30 PPI) 109-1002M30 (30 PPI)
109-1003M40 (40 PPI) 109-1002M40 (40 PPI)

64±1 85.5±1
50±0.3 71.5±0.3

64±1 85.5±1
50±0.3 71.5±0.3

4-ø10±0.5 4-2±0.5 4-ø10±0.5 4-2±0.5

92 mm sq. type Mass (g) 120 mm sq. type Mass (g)
25 44
Model no. Model no.
109-1001F13 (13 PPI) Quantity 109-1000F13 (13 PPI) Quantity
109-1001F20 (20 PPI) 109-1000F20 (20 PPI)
109-1001F30 (30 PPI) 5 109-1000F30 (30 PPI) 5
109-1001F40 (40 PPI) 109-1000F40 (40 PPI)
10.5±0.5 4-ø4.3±0.3 10.5±0.5 4-ø4.3±0.3
Replacement filter model no. Replacement filter model no.
109-1001M13 (13 PPI) 109-1000M13 (13 PPI)
109-1001M20 (20 PPI) 109-1000M20 (20 PPI)
109-1001M30 (30 PPI) 109-1000M30 (30 PPI)
109-1001M40 (40 PPI) 109-1000M40 (40 PPI)
96.5±1 124±1
82.5±0.3 104.8±0.3

96.5±1 124±1
82.5±0.3 104.8±0.3

4-ø9.5±0.5 4-2±0.5 4-ø11±0.5 4-2±0.5

Airflow - Static pressure characteristics Mounting example Filter replacement (example)

Measured with our double chamber Hexagonal Replacement filters can be replaced by
measuring device (120 mm sq. type) nuts (4) taking off the front part of the filter kit.
There is no need to remove the screws.
(Pa)
160
Option
140 Fan unit
Static pressure 120 (9G1212G101)
100
With lter kit
(109-1000F20) equipped*

80 With lter kit Fan

(109-1000F40) equipped*

60

40

20 Chassis Replacement lters
Filter kits
0 1 2 3 4 5 (m3/min) Small pan-head screws (4)
Air ow

Applied voltage: 12 VDC
* Filter kit is attached on air inlet side of fan.

Filter kit is one of the option to keep air in the chassis clean filtering dust in external atmosphere when pulling-air cooling is implemented. The filter kit is hooked up through
mounting hole of fan frame with screw as well as finger guard. Some performances (airflow & static pressure) of the fan motor decreases when filter kit is hooked up.
This Filter Kit is composed of 3 components, including a guard, a filter and a cover. It is delivered as a finished product at delivery, saving assembly time when mounting.
It can be mounted by inserting a screw in the apertures of the cover.
The filter and cover can be easily removed from the guard with one touch. There is no need for fan removal when undertaking maintenance. Operating temperature limit is between -10 to +60˚C. (non condensing)
The filter will deteriorate with age, and the level of deterioration will vary upon usage conditions. Please be aware that the filter has a greater tendency to deteriorate under high temperature and
humidity. For long-term storage, please store under the temperature range of 10 to 30˚C, humidity range of 20 to 65%. Usage and storage period is approximately 2 years.
Cooling ability decreases with filter contamination due to clogging. Filter replacement is recommended approximately every six months of usage. Please replace the filter if deterioration or
clogging is seen at inspection.
When replacing the filter, please use genuine SANYO DENKI filters. Do not water-wash the filter.
Avoid use and storage under high temperature or humidity, direct sunlight or exposure to ultraviolet light, or in corrosive gas. No nuts or screws for use in attachment included.

592 CATALOG No. C1111B001 '21.2.IT

Filter kits Applicable models: AC Fan 120 × 120 × 38 mm Dimensions, Reference Dimensions of Mounting Holes (unit: mm)
Neither filter kit can be installed on ACDC fans, or AC fans with sensors. Please evaluate it by assembly filter kits on the derice.

Model no. Material Mass (g)
109-018 Steel Wire Mesh: Stainless 16-mesh nets in 3 layers 182
Cover: Resin
Metal fittings: Steel (chromate-plated)

Dimensions Airflow - Static Pressure Characteristics

(64) (Measured with our double chamber measuring device)
8.5
(Pa) 109S005
80 109S005+109-018
70 Filter kits
60
Static pressure
131±0.8 50
60 Hz

40
50 Hz

30

20

10

155.6±0.8 0 1 2 3 (m3/min)

Air ow

Reference Dimensions of Mounting Holes Mounting Example Hexagon nut
Spring washer
44--4øm4穴m dia holes Mounting plate
Spncer Washer

Round head screw

127
89

131 Filter Fan
140.5 Installation brackets (2 pcs)
Holes for cabinet installation
The parts shown in the installation diagram (nuts, washers, and screws) are included.
Cover
(resin)

Screen kits Applicable models: AC Fan 120 × 120 × 38 mm Dimensions, Reference Dimensions of Mounting Holes (unit: mm)
Neither screen kit can be installed on ACDC fans, or AC fans with sensors.

Model no. Material Mass (g)
109-020 Steel Wire Mesh: Stainless 16-mesh nets in 1 layers 135
Cover: Resin
Metal fittings: Steel (chromate-plated)

Dimensions 8.5 Airflow - Static Pressure Characteristics

140.5±0.8 (Measured with our double chamber measuring device)

131±0.8 Static pressure(Pa) 109S005 Option
89±0.6 80 109S005+109-020
70 Screen kits
60
50 60 Hz
40 50 Hz
30
155.6±0.8 20 12 3 (m3/min)
10
Reference Dimensions of Mounting Holes Air ow
0
44--4øm4穴m dia holes
Mounting Example

Round head screw Washer
Mounting Plate
Spring washer
Screen Kit Hexagon nut

127
89

131 Fan
140.5 Installation brackets (2 pcs)
Holes for cabinet installation
The parts shown in the installation diagram (nuts, washers, and screws) are included.
593CATALOG No. C1111B001 '21.2.IT

Options

Plug cord for AC fan Dimensions (unit: mm)

Products compliant with electrical appliance and material safety law

For 80 × 80 × 42 mm For 80 × 80 × 25 mm, 80 × 80 × 38 mm, 92 × 92 × 25 mm,
120 × 120 × 25 mm
Model no. Power cord length [L] (mm) Mass (g)
489-008-L10 1000 30 Model no. Power cord length [L] (mm) Mass (g)
489-008-L21 2100 61 489-016-L10 1000 34
489-008-L35 3500 99 489-016-L21 2100 64

Flat 2-core vinyl cord Pre-soldered Flat 2-core vinyl cord
VFF0.75 mm2 VFF0.75 mm2
Black Black

16.5 11 Pre-soldered
7.5
<PS>E JET 20
3A 250V 17.5

ORIEX 9.5
11.5
5 3A 250V
10 1.5 ORIEX
5.6
50 10 <PS>E JET
L
4 18 50 10
10 24 L
20
6
25
8.9
8

6

For 120 × 120 × 38 mm (not including AC/DC fan) For 120 × 120 × 38 mm (not including AC/DC fan)

Model no. Power cord length [L] (mm) Mass (g) Model no. Power cord length [L] (mm) Mass (g)
489-006-L10 1000 47 489-037-L10 1000 46
76
489-006-L21 2100 76 489-037-L21 2100 114
489-006-L35 3500 114 489-037-L35 3500

(Exclusive for fans without UL at the end of the model number.) (Exclusive for fans with UL at the end of the model number.)

VSF1.25 mm2 VSF1.25 mm2
For ground, Black For ground, Black

7.9 600+200 7.9 R1 600+200

Pre-soldered Pre-soldered

IN G <PS> E JET ORIEX G IN G 8 <PS>E JET ORIEX G
3A 250V 21.2 3A 250V
58 24.7
19.5 26.9
26.9
50 10
L 5 50 10
L
4 Flat 2-core vinyl cord 4
24 VFF0.75 mm2 24 Flat 2-core vinyl cord
Black VFF0.75 mm2
Black

For 160 × 160 × 51 mm For ø172 × 51 mm, ø172 × 150 × 51 mm,
160 × 160 × 51 mm
Model no. Power cord length [L] (mm) Mass (g)
489-1618-L10 1000 34 Model no. Power cord length [L] (mm) Mass (g)
489-1618-L21 2100 63 489-1619-L10 1000 34
489-1618-L28 2800 83 489-1619-L21 2100 64

Option 17.5 ORIEX L 50 10 19.5 18.5 3A 250V
8 3A 250V Pre-soldered 18
〈PS〉E JET 〈PS〉E JET
ORIEX S272

20 4 16.5 19
40.5
R0.3 9 5.5 Flat 2-core vinyl cord 9.5
11 VFF0.75 mm2
Black

9 50 10
13.5 16.5 Pre-soldered

30

L

17.5
8

Flat 2-core vinyl cord
VFF0.75 mm2
Black

●Be careful not to damage the plug/cord when taking them out of the package.

594 CATALOG No. C1111B001 '21.2.IT

Plug cord for AC fan Dimensions (unit: mm)

UL/CSA certified UL file no.: E50197 CSA file no.: LR67048

For 120 × 120 × 38 mm (not including AC/DC fan) For 80 × 80 × 25 mm, 80 × 80 × 38 mm, 92 × 92 × 25 mm,
120 × 120 × 25 mm
Model no. Power cord length [L] (mm) Mass (g)
48
489-007-L10 1000 80 Model no. Power cord length [L] (mm) Mass (g)
489-007-L21 2100 489-047-L10 1000 38
489-047-L21 2100 71
(Exclusive for fans with UL at the end of the model number.)

UL 1015 AWG18 Flat 2-core vinyl cord
For ground, green/yellow spiral UL SPT-1 AWG18
Black
Pre-soldered 11 7.5 R1
8.9 17.5 Pre-soldered

60 0 +20 11.5
0 9.5
20
8 8.2
24.7

4 18 50 10
24
4 26.9 50 10 L
24 Flat 2-core vinyl cord R1
L UL SPT-1 AWG18
Black R1.5

7.9 8
6

For ø172 × 51 mm, ø172 × 150 × 51 mm, For 160 × 160 × 51mm
160 × 160 × 51 mm
Model no. Power cord length [L] (mm) Mass (g)
Model no. Power cord length [L] (mm) Mass (g) 489-086-L10 1000 37
489-084-L10 1000 37 489-086-L21 2100 70
489-084-L21 2100 70

16.5 8 ORIEX L
15.5 17.53A 250V 50 10
5.5
Pre-soldered

9 9 16.5 4 16.5 Flat 2-core vinyl cord
13.5 16.5 UL SPT-1
AWG 18
30 10 11 37 Black
L
50

8 Pre-soldered
Flat 2-core vinyl cord
UL SPT-1
AWG 18
Black

Plug cord for ACDC fan Dimensions (unit: mm)

Products compliant with electrical appliance and material safety law, UL/CSA [c-UL] certified
UL file no.E43202

Model no. Power cord length [L] (mm) Mass (g) 8
489-1635-L10 1000 38 10
489-1635-L21 2100 74
15.5 8

Option
L
P先re端-s予o備ldはerんedだ

4 10 50±5 10±2
20 4 17

F平la形t 22-芯coビreニvーinルylコcoーrドd
SSPPTT-1-1&&HHVVFFFF
00.7.755mmmm22((AAWWGG1188))
B黒lack

Wiring Harness for Sensor

Model no. Mass (g) 1000±20
489-1636 9
10±1
Pre-soldered

●Be careful not to damage the plug/cord when taking them out of the package.

595CATALOG No. C1111B001 '21.2.IT

Options

Typical Connectors for DC Fans
Listed below are the typical contact/housing connectors with a proven track record with our products. For customization details, contact us.

Manufacturer 2 pins 3 pins 4 pins 6 pins 8 pins Contact model number
Housing model number Housing model number Housing model number Housing Housing
model model 08-55-0130:P/N 2759-(558)B
number number 08-50-0113:P/N 2759-(P909)B
794617-8
22-01-1022:P/N 5051-02* 22-01-1032:P/N 5051-03* 22-01-1042:P/N 5051-04* 08-70-0064:P/N 5159T*
22-01-3037:P/N 2695-03RP* 08-70-0048:P/N 5159PBT*
22-01-3047:P/N 2695-04RP 39-00-0372:P/N 2759T*
47054-1000
39-00-0374:P/N 2759GS
MOLEX 39-00-0376:P/N 2759G
39-00-0380:P/N 2759PBG
43025-0200* 43025-0400* 44133-0600
43030-0001*
51191-0200* 51191-0300* 51021-0400 43030-0002*
43030-0003*
50-37-5023:P/N 5264-02* 50-37-5033:P/N 5264-03* 51191-0400*
50-37-5043:P/N 5264-04* 43030-0004
39-01-2020:P/N 5557-02R* 39-01-2040:P/N 5557-04R* 43030-0005
171822-4* 43030-0006
171822-2* 171822-3* 179228-4* 46235-0001
TE Connectivity 179228-2* 179228-3* 50079-8000

Hirose DF1B-2EP-2.5RC* DF1B-3EP-2.5RC* DF3-4EP-2C* 50802-9001*
DF3-2EP-2C* DF3-3EP-2C* DF3AA-4EP-2C*
DF3AA-2EP-2C* DF3AA-3EP-2C* EHR-4* 50802-8000
EHR-2* EHR-3* SMP-04V-BC*
SMP-02V-BC* SMP-03V-BC* 08-70-1039:P/N 5263PBT*
SMP-02V-NC* SMP-03V-NC* PHR-4* 39-00-0059:P/N 5556PBT*
H2P-SHF-AA* H3P-SHF-AA* XAP-04V-1* 39-00-0038:P/N 5556T*
170262-1*
PHR-2* PHR-3* 179227-1*

Japan Solderless XAP-02V-1* XAP-03V-1* 1-794607-1
Terminals XMP-02V* XMP-03V*
DF1B-2428PCF*
XHP-2* XHP-3* XHP-4*
DF3-EP2428PCF*
Option SMR-02V-B* SMR-03V-B* SMR-04V-B*
SMR-02V-N* SMR-03V-N* SMR-04V-N* SEH-001T-P0.6*

* Recommended connectors ZHR-4 SHF-001T-0.8BS*

SPH-002T-P0.5S*

SPH-002T-P0.5L

SXA-001T-P0.6*

SXA-01T-P0.6

SXH-001GU-P0.6*
SXH-001T-P0.6*

SXH-002T-P0.6

SYM-001T-P0.6*

SZH-002T-P0.5

Recommended tubes and cable ties for DC fan

Manufacturer Representative model numbers Specifications UL file no.
E55011
PVC tube YAMAICHI CHEMICAL YET-300H 105˚C 300 V VW-1 E56036
IWASE KAGAKU KOGYO AH-3
E48762
Thermal contraction SUMITOMO ELECTRIC SUMITUBE® F2 (Z) 125˚C 600 V VW-1
tube SUMI-PAC SUMITUBE® F32 E49405
E56854
THOMAS & BETTS TY-23M E64962

Cable tie PANDUIT BT1M UL 94V-2

HellermannTyton T18R

Note: The specifications in this table are for reference purposes only. When selecting, please check catalogs of each brand.

596 CATALOG No. C1111B001 '21.2.IT

Technical Material

Overview and Characteristics of Fan

Overview

A cooling fan is widely used to extend life of your system by cooling off heat of the system that many electrical components are mounted
in a very high density and dissipating heat. Since we SANYO DENKI developed San Ace which is the first AC fan in Japan in 1965, we have
increased fan motor lineup until now meeting customer s needs rapidly based on our tremendous career. We SANYO DENKI will continue to
develop new fans with high airflow, low noise, low vibration, and energy - saving design.

Characteristics

We can roughly devide fan into two types which are AC and DC. DC fans

AC fans SANYO DENKI succeeded in the mass-production of DC fans in
1982.
SANYO DENKI succeeded in the mass-production of AC fans in
1965. SANYO DENKI was the first Japanese manufacturer to have High performance
succeeded at this. Low power consumption
Low vibration
High performance Low leakage of flux
High reliability High reliability
Safety

SANYO DENKI currently has a wider variety of products like Long Life Fan, CPU cooler, Splash Proof Fan, and Oil Proof Fan etc to meet all
customer needs.

Reliability and expected life Expected life of DC fans

A cooling fan generally cools itself as well. 1000000
The temperature rise of the motor is relatively
low and the temperature rise of the grease 100000 Expected life 180000 h (L10, 60˚C)
in the bearings is also low, so expected life Expected life 150000 h (L10, 60˚C)
is longer than general some either motors. Expected life (h) Expected life 60000 h (L10, 60˚C) Expected life 130000 h (L10, 60˚C)
Since the service life of bearings is a Expected life 40000 h (L10, 85˚C)
theoretical value that applies when they are 10000 Expected life 40000 h (L10, 60˚C)
ideally lubricated, the life of lubricant can be Expected life 30000 h (L10, 60˚C) Expected life 100000 h (L10, 60˚C)
regarded as expected life of the fan. DC fan Expected life 80000 h(L10, 60˚C)
consumes less power and its temperature rise
of bearing is very low. When the measurement 1000 20 40 60 80 100
conditions are: L10 (the remaining product Ambient temperature (˚C)
life in the lifespan test is 90%),with an
atmospheric temperature of 60 degrees, at Rated voltage, continuously run in a free air state, survival rate of 90%
the rated voltage, and continuously run in a
free air state. The table below indicates the
relationship between ambient temperature
and expected life estimated on the basis of our
life tests and same other tests conducted by
SANYO DENKI.

Expected life of AC fans

1000000

100000 Expected life 60000 h (L10, 60˚C) Technical Material
(ACDC fans 92×92 mm, 120×120 mm)

Expected life 40000 h (L10, 60˚C)
(ACDC fans ø225 mm)

Expected life (h) Expected life 25000 h (L10, 60˚C)
(AC fans)
10000

1000 20 40 60 80 100

Ambient temperature (˚C)

Rated voltage, continuously run in a free air state, survival rate of 90%

597CATALOG No. C1111B001 '21.2.IT

Technical Material Fan
Noise meter
Noise characteristics
Noise is average value that measured at l meter away from air intake side of fan
that is suspended on special frame in anechoic chamber (as per JIS B 8346).

AIRFLOW 1m

Acoustic radio wave anechoic chamber Noise characteristic measurement equipment

Measuring airflow and static pressure Q 60Av¯ (A)
where
It is very difficult to measure airflow and static pressure. In fact,
the performance curve may vary greatly according to the type of Q = airflow (m3/min)
measuring equiment.
The commonly-used type of measuring equipment is a wind tunnel A = cross sectional area of nozzle 4 D2 (m2)
using a Pitot tube. SANYO DENKI uses a very precise method using D = nozzle diameter
double chamber equipped with many nozzles. v¯ = average airflow velocity of nozzle 2gPn (m/s)

U-shaped tube Specific weight of air = g (N/m3)

Pn Throttle device (Air density = 1.2 kg/m3 at 20˚C, 1 atm)
Ps
g = acceleration of gravity = 9.8 (m/s2)

Pn= differential pressure (Pa)

Chamber B Ps= static pressure (Pa)

U-shaped tube Chamber A

BM The measuring equipment using double chanber is method to
Nozzle be calculated from airflow goes through nozzle and differential
pressure between pressure of inside of chamber (Ps) and
Auxiliary blower atomospheric pressure by measuring differetial pressure between
Fan to be measured air intake and exhaust of nozzle (Pn).
Double chamber measuring equipment

Conversion table Airflow

Static pressure 1 m3/min 35.31 ft3/min (CFM)
1 CFM 0.0283 m3/min
1 mm H2O 0.0394 inch H2O 1 m3/min 16.67 /s
1 mm H2O 9.8 Pa (Pascal)
1 inch H2O 25.4 mm H2O 1 CFM 0.472 /s
1 Pa 0.102 mm H2O 1 /s 0.06 m3/min
1 inch H2O 249 Pa

Technical Material

598 CATALOG No. C1111B001 '21.2.IT

Motor Protection Technical Material

If the fan blades are restricted, an overcurrent occurs and leads to a rise in the fan coil temperature. This can result in
reduced performance, damage, or a fire. To prevent this from occurring, SANYO DENKI's fans incorporate an overheating
protection function.

Reverse polarity protection function (DC fan)

No problem about fan even if positive & negative lead are connected in reverse.
However, when wiring fans with sensors or PWM speed control function, connecting positive and negative leads in reverse
may damage the fans.

Burnout protection function at locked rotor condition (DC fan, ACDC fan)

Current cutoff system
If the fan blades are restricted, the coil current is cut off at regular cycles to prevent overheating of the coil. When the
hindrance is removed, the fan restarts automatically.

Burnout protection function at locked rotor condition (AC fan)

Impedance protection (60 mm sq., 80 mm sq., 92 mm sq., 120 mm sq.)
This system is used for shading coil-type fans. When the blades are restricted, the current is reduced by the impedance of
the coil itself to prevent a temperature rise in the coil. However, if the applied voltage exceeds the specification range, an
overcurrent can occur and result in overheating, and so care needs to be taken.
Thermal protection (160 mm sq., ø172 mm)
This system is used for condenser phase-type fans. A temperature sensor is incorporated in the coil so that if the
temperature exceeds the specification temperature, the current is cut off to prevent overheating of the coil.

599CATALOG No. C1111B001 '21.2.IT

Technical Material

Guideline in Selecting a Fan

How to select an appropriate fan
The following example is a guideline regarding how to select an appropriate fan for cooling your system

1. Determining of your system specifications System
and conditions Fan

Determine the temperature rise inside your system and obtain the total heating ℃ Q'
value inside your system on the basis of its inputs and outputs.
T
Example
V: Total heating value of your system (W)=100 (W) V
T: Inside temperature rise (K)=15 (K)

Heat source

2. Calculating the required airflow for cooling
After the equipment specifications and conditions of your system have been determined, calculate required airflow to meet the conditions.

(Note that the formula shown below only applies when the heat radiation is performed only by cooling air from the fan.)

Example

Q': Motion airflow (m3/min)

Q'= V = 100 (W) 0.33 (m3/min)
20 T 20×15 (K)

3. Selecting the fan

After the motion airflow has been calculated, select an appropriate fan motor based on the value.The motion airflow when the fan motor is

actually mounted in your system can be obtained using the airflow-static pressure characteristics curve and system impedance.However,

the system impedance cannot be measured without a measuring equipment, so fan with 1.5 to 2 times higher airflow than the actual max

airflow should be selected (operating airflow is one-third to two-thirds of maximum airflow).

Example

Q: Maximum airflow (m3/min) Characteristics of air ow versus static pressure
and those of pressure losses of equipment
Q'=Q×2/3
Q=Q'×3/2=0.33×3/2 0.5 (m3/min) Static pressure

Next, In case that you select a fan having an airflow of 0.5 (m3/min) or more and a appropriate

size for the space inside your system. System impedance

For example, If you need a fan of 60 mm square, 25 mm thickness and 12 V, you should select

is 109R0612H402 (maximum airflow = 0.53 m3/min). Pressure loss

4. Confirming the selected fan Operating air ow Air ow

Calculate the temperature rise inside your sysetem when your sysetem having 100 (W) of
total heating value is forcefully cooled down by a 109R0612H402 fan.

Example
Q' =Q×2/3=0.53×2/3 0.353 (m3/min)
T =V/20Q'=100 (W)/20×0.353 (m3/min) 14.2 (K)

From the above, the temperature rise inside your system is calculated as 14.2 (K).

Since the value obtained from the above equation is only a rough target, final fan selection should be based on your actual installation test.

Technical Material Portable measuring device for measuring airflow and system impedance within equipment

San Ace Airflow Tester
■Features

Enables the selection of the optimal fan for a device
An optimal fan for a device can be selected by entering accurate measurement
results into thermal design simulation software.
Compact and lightweight
With a compact design and weight of approximately 6 kg, it is portable enough
to measure immobile equipment.

Please refer to page 578 for detail.

With connection duct mounted

600 CATALOG No. C1111B001 '21.2.IT


Click to View FlipBook Version