2. Perhitungan tubine dan plant heat rate
235
PUSAT SERTIFIKASI
236
PUSAT SERTIFIKASI
VI.2.2 Dengan Standar ASME PTC 4.1
Untuk PLTU dengan boiler tipe CFB ini dan perhitungan boiler efisiensi menggunakan
ASME PTC 4.1, Penulis mengambil contoh untuk perhitungan performance test PLTU
Punagaya (2 x 110 MW).
Data Teknik Gambar - 139 : PLTU Punagaya (2 x 110 MW)
Nama Pembangkit
Unit Pembangkit : PLTU Punagaya 2 x 100 MW
Bahan bakar : Unit 1
Koordinat : Batubara
: S: 05°37'27.93” E: 119033’03.5”
Boiler : Wuxi Huanguang Boiler Co., Ltd
- Pabrik : CFB
- Jenis : UG-443/9.3-M
- Tipe : 2015
- Tahun pembuatan : 16001
- Nomor seri : 443 t/h
- Kapasitas : 9.3 MPa
- Tekanan uap utama : 540 0C
- Temperatur uap utama
237
- Tekanan uap reheat PUSAT SERTIFIKASI
- Temperatur uap reheat
Turbin :-
- Pabrik :-
- Tipe
- Tahun pembuatan : Harbin Turbine Co., Ltd
- Daya nominal : N110-8.83/535
- Nomor seri : 2016
- Putaran : 110 MW
- Tekanan uap utama :-
- Temperatur uap utama : 3000 rpm
- Tekanan uap reheat : 8.826 MPa
- Temperatur uap reheat : 535 ˚C
Generator :-
- Pabrik :-
- Tipe
- Tahun pembuatan :Harbin Electric Co., Ltd
- Nomor seri : QF-110
- Daya nominal : 2016
- Tegangan : 3-61058
- Arus : 129.4 MVA
- Putaran : 13.8 kV
- Frekuensi : 5414 A
- Tegangan Eksitasi : 3000 rpm
- Arus Eksitasi : 50 Hz
- Jumlah fasa : 241 V
- Faktor daya : 1288 A
:3
Transformator Utama : 0.85
- Pabrik
- Tipe :Tianwei Baobian (Hefei) Transformer Co.,Ltd
- Tahun pembuatan : SFZ-125000/150TH
- Nomor seri : 2016
: 2016 05F04
238
PUSAT SERTIFIKASI
- Sistem pendinginan : ONAN/ONAF
- Jumlah fasa :3
- Kapasitas terpasang : 125 MVA
- Tegangan sisi HV : 157.5 kV
- Tegangan sisi LV : 13.8 kV
- Arus sisi HV : 458,2 A
- Arus sisi LV : 5230 A
- Jumlah Tap : 17
- Frekuensi : 50 Hz
- Kelompok vektor : Ynd11
- Impedansi :13.7 %
1. Perhitungan efisiensi boiler
239
PUSAT SERTIFIKASI
240
PUSAT SERTIFIKASI
241
PUSAT SERTIFIKASI
2. Perhitungan Elektrik
242
PUSAT SERTIFIKASI
3. Perhitungan turbine heat rate
243
PUSAT SERTIFIKASI
244
PUSAT SERTIFIKASI
245
PUSAT SERTIFIKASI
246
PUSAT SERTIFIKASI
4. Contoh penerapan kurva koreksi
247
PUSAT SERTIFIKASI
5. Resume
248
PUSAT SERTIFIKASI
VI.3 PLTU dengan Boiler Tipe Pulverized (Sub critical)
Untuk PLTU dengan boiler tipe pulverized (Sub critical) ini, Penulis mengambil contoh
untuk perhitungan performance test PLTU Tanjung Awar-awar (2 x 350 MW).
Gambar - 140 : PLTU Tanjung Awar-awar (2 x 350 MW)
Data Teknik : PLTU Tanjung Awar-awar (2 x 350 MW)
Nama Pembangkit : Unit 1
Unit Pembangkit : Batubara
Bahan bakar : S: 06,49’39”, E: 112’27”
Koordinat
249
PUSAT SERTIFIKASI
1. Boiler :
Manufaktur : HarBin Boiler Company Limited
Model : HG-1175/17.5-HM
Tipe : Pulverized boiler
Serial number : 3396
Boiler Maximum Continuous Rating (BMCR) :
Superheater steam flow : 1175 t/h
Superheater steam pressure : 17,5 MPa (g)
Superheater steam temperature : 541 °C
Reheater steam outlet flow : 971,05 t/h
Reheater steam outlet pressure : 3,724 MPa (g)
Reheater steam outlet temperature : 541 °C
Reheater steam inlet pressure : 3,914 MPa (g)
Reheater steam inlet temperature : 336,9 °C
Feedwater pressure (at economizer inlet) : 19,292 MPa (g)
Feedwater temperature (at economizer inlet) : 283,7 °C
Flue gas temperature at air preheater outlet
(uncorrected value) : 146,1 °C
Flue gas temperature at air preheater outlet
(corrected value): : 140,6 °C
Primary air temperature at air preheater outlet : 391,1 °C
Secondary air temperature at air preheater outlet : 391,1 °C
Excess air ratio at furnace outlet : 1,2
Boiler guaranteed efficiency (TMCR) : 92,5 %
Minimum load operation without oil support :35 %
Air preheater : 2 trisector Ljungstrom air
preheaters
2. Turbine :
Manufaktur : Harbin Steam Turbine Co., LTD
Model : N350-16.70/538/538
Tipe : sub critical parameter, once reheat, tandem compound two
cylinders, double exhaust, condensing steam turbine.
250
PUSAT SERTIFIKASI
Serial Number : 116091
Turbine MaximumContinuous Rating (TMCR):
Rated output (guarantee) : 350 MW
Main steam flow : 1111,83 t/h
Main steam pressure : 16.70 MPa (a)
Main steam temperature : 538 °C
Reheat steam flow : 922,38 t/h
Reheat steam temperature : 538 °C
T-G heat rate : 8164,3 KJ/KWh
Steam rate : 3,177 Kg/KWh
Rated back pressure : 8,5 kPa (a)
Rated cooling water temperature : 30 °C
Rated speed : 3000 rpm
Maximum output at VWO : 365,653 MW
Main steam flow at VWO : 1175 t/h
Maximum feedwater temperature : 280 °C
3. Generator :
Manufaktur : Harbin Generator Co., LTD
Model : QFSN-350-2
Tipe : sub critical parameter, once reheat, tandem
compound two cylinders, double exhaust,
condensing steam turbine.
Serial Number : 3-60801
Rated capacity : 412 MVA
Rated output : 350 MW
Maximum rating : 385 MW
Rated power factor : 0.85 (lag)
Rated voltage : 20 Kv
Rated stator current : 11887 A
Exciting voltage (design date) : 368 V
Exciting current (design date) : 2897 A
Rated speed : 3000 r/min
251
PUSAT SERTIFIKASI
Rated frequency : 50 Hz
Number of phases :3
Rated efficiency (guarantee) : 98.9%
Excitation mode : static
Stator winding connection type : YY
Number of terminal of stator winding : 6
Cooling mode : water-hydrogen-hydrogen
Rated hydrogen pressure : 0,35MPa (g)
4. Generator Transformator:
Manufacture : TBEA Hengyang Transformer Co. Ltd
Product Type : SFP – 420000/157,5
Serial No. : 081025 A
Product Drawing No. : 1TBEA.710.30217
No. of Phase : 3 Phase
Rated Capacity : 420000/420000 kVA
Rated Voltage : 157,5/20 kV
Rated Frequency : 50 Hz
Tapping Range : (157,5 ± 2 X 2,5% kV)
Rated Current : 1539,6 / 12124,4 A
Vector Group : YNd11
Altitude : <1000 m
Cooling Type : ONAN / ONAF / OFAF
Year : 2011
Insulation Level : LI750AC375 – LI400AC200 – LI170AC70
252
PUSAT SERTIFIKASI
1. Perhitungan efisiensi boiler
253
PUSAT SERTIFIKASI
254
PUSAT SERTIFIKASI
255
PUSAT SERTIFIKASI
256
PUSAT SERTIFIKASI
2. Perhitungan elektrikal
3. Perhitungan tubine heat rate
257
PUSAT SERTIFIKASI
258
PUSAT SERTIFIKASI
259
PUSAT SERTIFIKASI
260
PUSAT SERTIFIKASI
4. Ikhtisar
261
PUSAT SERTIFIKASI
262
PUSAT SERTIFIKASI
VI.4 PLTU dengan Boiler Tipe Pulverized (Ultra super critical)
Gambar - 141 : PLTU JAWA 7 ( 2 x 1000 MW)
Data Teknik
Nama Pembangkit : PLTU JAWA 7 (2x1050 MW)
Unit Pembangkit :1
Bahan bakar : Batubara
Koordinat : S 5° 59’31”, E 106° 06’0.2”
1. Boiler
- Pabrik : Babcock & Wilcox Beijing Co. Ltd.
- Jenis : Ultra Supercritical Boiler
- Tipe : B&WB-3100/28.25-M
- Tahun pembuatan : 2018
- Kapasitas : 2998 t/h
- Tekanan uap utama : 28,16 MPa
- Temperatur uap utama : 605 ˚C
- Tekanan uap reheat : 6,189 / 5,999 MPa
- Temperatur uap reheat : 369 / 603 ˚C
2. Turbin
- Pabrik : Shanghai Electric
- Tipe : N1050-27/600/600
- Tahun pembuatan : 2018
263
- Daya nominal PUSAT SERTIFIKASI
- Nomor seri
- Putaran : 1073 MW
- Tekanan uap utama : Unit 1: A196-10-17
- Temperatur uap utama : 3000 rpm
- Tekanan uap reheat : 27 MPa
- Temperatur uap reheat : 600 ˚C
3. Generator : 5,698 MPa
- Pabrik : 600 ˚C
- Tipe
- Tahun pembuatan : Shanghai Electric
- Nomor seri : QFSN-1073-2
- Daya nominal : 2018
- Tegangan : Unit 1: B1200W30C004
- Arus : 1268 MVA
- Putaran : 27 kV
- Frekuensi : 27001 A
- Tegangan Eksitasi : 3000 rpm
- Arus Eksitasi : 50 Hz
- Jumlah fasa : 157 V
- Faktor daya : 1885 A
4. Transformator Utama :3
- Pabrik : 0,85
- Tipe
- Tahun pembuatan : Changzhou Toshiba
- Nomor seri : SFFZ-93000/500
- Sistem pendinginan : 2018. 02
- Jumlah fasa : Unit 1: C2018022
- Kapasitas terpasang : ODAF
- Tegangan sisi HV : 3 Fasa
- Tegangan sisi LV : 1330 MVA
- Arus sisi HV : 500 kV
: 27 kV
: 1463 A
264
PUSAT SERTIFIKASI
- Arus sisi LV : 28440 A
- Jumlah Tap : 21
- Frekuensi : 50 Hz
- Kelompok vektor : YNd11
- Impedansi : 19.77 %