ADEX

ADEX VALVE

A05P, A05R Series

Optional Accessories and Spare parts

Collective wiring connector AB plate
A05R AB M5
A05PS CC □
Port size
Polarity M5 : M5
C4 : * With push-in fitting for φ 4
Type No mark : NPN type C6 : * With push-in fitting for φ 6

M : * PNP type

PS : For PR type single solenoid

PD : For PR type double solenoid

For PR type single solenoid Mounting Mounting
screw screw
For PR type double solenoid
AB plate AB plate
(Tapped hole (With push-
type) in fitting)
Plate gasket
Plate gasket

Locking cover Blank plate For A05R
A05P LA
For A05P A05RG BP
Color
A : Orange A05PG BP Mounting
screw
(Note) For common use with all A05 and A12 Mounting Blank plate
screw
Tag for solenoid valve Blank plate Manifold
A 0 5 P N (Pack of 10) gasket
Base
Tag gasket Blank
cover
Blank
cover

Solenoid valve Manifold gasket
A05R G
(Note) For common use with sub-base mountig type of A05
and A12 Content of kit
SG : Gasket & mounting screws
Base gasket G : Gasket only(Pack of 10)
A05PX G S : Mounting screw only (Pack of 20)

Content of kit Mounting screw
SG : Gasket & mounting screws
G : Gasket only(Pack of 10) Manifold gasket
S : Mounting screw only (Pack of 20)

Special specifications
No mark : Standard

X : * For external pilot(With port X)

Mounting screw

Base gasket

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

51

ADEX VALVE (Unit : mm)

A05P, A05R Series

DMimCeCn□s-Aio0n5s-M5 C4, C6 -DL

With locking cover

5.4

φ 9.4 4.7 11.3 21.5
22.7
(51.5) 6.5 49.5
44.5
61.5 3
A05PS25 A05PD25
D sub-connector(25P) A05PD35,A05PE35,A05PO35

50 6 Blank plate A05PG-BP

3-Rc1/8(Both side)
(Port 1,3,5)

42 24 0.2 51 3
26
10 6 50

(7.3 : For C4) 9.5 6 58 2-M2.6 4-φ 4.5
(8.4 : For C6) 12.5 (Mounting hole)
13 4 P=12.5n+34.5
L=12.5n+42.5 (4)

4 2n-M5
2 (Push-in fitting for 2n-φ 4 : C4)
(Push-in fitting for 2n- φ 6 : C6)
1.4 4.4 (Port 2 & 4)
38 12.5
64.6 36.5
29.5
21
6

Parker Hannifin Corporation
Pneumatic Division

52

ADEX VALVE (Unit : mm)

A05P, A05R Series

DMimCeCn□s-Aio0n5sP-M5 C4, C6 -ML

With locking cover

5.4

φ 9.4

(63.5) 4.7 11.3 21.5
44.5

A05PS25 A05PD25
Flat cable connector(26P) A05PD35,A05PE35,A05PO35
Blank plate A05PG-BP
22
3-Rc1/8(Both side) 50 6 61.5 3
(Port 1,3,5)

42 1.2 51 3 49.5
26
10 24 22.7

(7.3 : For C4) 9.5 6 58 6 50 6.5
(8.4 : For C6)
12.5 4-φ 4.5
13 (Mounting hole)

4 P=12.5n+34.5 (4)
L=12.5n+42.5
2n-M5
4 (Push-in fitting for 2n-φ 4 : C4)
2 (Push-in fitting for 2n-φ 6 : C6)
(Port 2 & 4)
1.4 4.4
64.6 38 12.5 36.5
29.5
21
6

Parker Hannifin Corporation
Pneumatic Division

53

ADEX VALVE (Unit : mm)

A05P, A05R Series

DMimCeS□ns-Aio0n5sP-01-DL, MCX□-A05P-01 C4, C6 -DL

With locking cover

5.4

φ 9.4 6 50 0.2 47 4.7 11.3 24
24 (54) 30.2
M5(Both side) A05PS25(For MCS) A05PD25(For MCS)
(X port for MCX) A05PS25X(For MCX) 57A05PD25X(For MCX)
D sub cable connector(25P) 69 3A05PD35,A05PE35,A05PO35(For MCS)
3-Rc1/8 (Both side) A05PD35X,A05PE35X,A05PO35X(For MCS)
(P, R1, R2 port) 22
Blank plate A05PG-BP

50 6 5 X 1 3Y

49.5 6 58
47.5
33.5
17.5

(7.3 : For MCX-C4) M5(Both side) 2-M2.6 4-φ 4.5
(8.4 : For MCX-C6) (Y port for MCX) (Mounting hole)
11.5
14.5

27.5

4 P=12.5n+34.5 (4)
L=12.5n+42.5
2n-Rc1/8
4 (Push-in fitting for 2n-φ 4 : MCX-C4)
2 (Push-in fitting for 2n-φ 6 : MCX-C6)
(Port 2 & 4)
1.4 4.4
67.1 38 12.5 39
32
22

7.5

Parker Hannifin Corporation
Pneumatic Division

54

ADEX VALVE (Unit : mm)

A05P, A05R Series

DMimCeS□ns-Aio0n5sP-01-ML, MCX□-A05P-01 C4, C6 -ML

With locking cover

5.4

φ 9.4

24

(66)
47

M5(Both side) A05PS25(For MCS) A05PD25(For MCS)
(Port X for MCX) A05PS25X(For MCX) A05PD25X(For MCX)
Flat cable connector(26P) A05PD35,A05PE35,A05PO35(For MCS)
3-Rc1/8(Both side) A05PD35X,A05PE35X,A05PO35X(For MCX)
(Port 1,3,5) 22
Blank plate A05PG-BP

50 6 5X 1 3 Y 11.3 69 3

49.5 24 1.2 4.7 30.2
47.5
33.5 6 58 6 50
17.5

(3.6 : For MCX-C4) 11.5 M5(Both side) 4-φ 4.5
(8.4 : For MCX-C6) 14.5 (Port X for MCX) (Mounting hole)

27.5

4 P=12.5n+34.5 (4)
L=12.5n+42.5
2n-Rc1/8
4 (Push-in fitting for 2n-φ 4 : MCX-C4)
2 (Push-in fitting for 2n-φ 6 : MCX-C6)
(Port 2 & 4)
1.4 4.4
67.1 38 12.5 39
32
22

7.5

Parker Hannifin Corporation
Pneumatic Division

55

ADEX VALVE (Unit : mm)

A05P, A05R Series

DMimCeUn□s-Aio0n5sR-M5 C4, C6 -DL

With locking cover

5.4

φ 9.4

(49) 8 8 19
42 23.5

D sub-connector(25P) A05RD2547
9 59 3
3-Rc1/8 (Both side) 50 6 A05RS25 A05RD35,A05RE35,A05RO35
(Port 1,3,5) 22
2m-Rc1/8
(Push-in fitting for 2n- φ 4 : C4)
(Push-in fitting for 2n- φ 6 : C6)
(Port 2 & 4)

Blank plate A05RG-BP

39.5 24 5.1 5.1 3.5 513
23.5
7.5 9.5 6 58 6 50
15.5
2-M2.6 4-φ 4.5
52 (Mounting hole)
(62.7 : For C4) 4 P=12.5n+34.5
(63.5 : For C6) L=12.5n+42.5 (4)

59.1 31
24

38 12.5

Parker Hannifin Corporation
Pneumatic Division

56

ADEX VALVE (Unit : mm)

A05P, A05R Series

Dimensions

MCU□-A05R-M5 C4, C6 -ML

With locking cover

5.4

φ 9.4

(61) 8 8 19
42 23.5

A05RS25 47A05RD25
9 59 3A05RD35,A05RE35,A05RO35
Flat cable connector(26P)
2m-M5
50 6 22 (Push-in fitting for 2n- φ 4 : C4)
(Push-in fitting for 2n- φ 6 : C6)
(Port 2 & 4)
Blank plate A05RG-BP

3-Rc1/8 (Both side)
(Port 1,3,5)

16 16 24 5.1 5.1 513
4.5

9.5 6 58 6 50 4- φ4.5
15.5 (Mounting hole)

52 4 P=12.5n+34.5 (4)
L=12.5n+42.5
(62.7 : For C4)
(63.5 : For C6)

59.1 31
24

38 12.5

Parker Hannifin Corporation
Pneumatic Division

57

ADEX VALVE

5 Port pilot operated solenoid valve

A12P Series

Rubber Seal /Sub-base Mounting type

A12PS25 2-position
A12PD25 Single solenoid
A12PD35
A12PE35 2-position
A12PO35 Double solenoid

3-position
Closed center

3-position
Exhaust center

3-position
Pressure center

Specifications Unit A12PS25 A12PD25 A12PD35 A12PE35 A12PO35
mm2
Model No. Non-lubricated / lubricated air 14.1
Fluid 0.78
Port size Rc1/8
Effective area
Cv value 11.1 7.6
Operating ambient temperature
0.61 0.42

5 50

Pressure range MPa 0.15 0.7 0.1 0.7 0.2 0.7

0.1 0.7 For external pilot operation

Maximum frequency cycle/min 600 500

Response ON s 0.015 0.010 0.012
time DC s 0.018 (0.024) 0.036 (0.042)

OFF

Pilot air exhaust Captured exhaust

Manual override Screwdriver-operated locking button

Mounting position Free
150/30
Shock resistance, m/s2 75 79
vibration resistance g 161 166
g
Mass Without sub-base 60
With sub-base 143

(Note) ● Service kit not available
● When temperature of valve site goes down below 5 , complete dry air should be supplied to prevent from freezing.
● Pressure range of external pilot supply : 0.25 0.7MPa
● Response time in bracket ( ) shows with surge suppressor.
● Response time shown above is in accordance with JIS B 8375.
● Effective area shown above is a value between ports 1 and 2, 4.

Electrical Specifications

Rated voltage DC V 24

Permissible voltage fluctuation % 10, 10

Power DC W 0.6 (with indicator light and surge suppressor), 0.55 (without indicator light and surge suppressor)
consumption

Grade of Insulation JIS grade E
Wiring Plug-in connector
Surge suppressor
Indicator light Diode
LED

Parker Hannifin Corporation
Pneumatic Division

58

ADEX VALVE

A12P Series 1 P 02 E

Ordering Instructions Wiring
No mark: Without connector
A12P S25
E : Connector with lead wire
Function (Length : 500mm)
S25 : 2-position, single solenoid
Port size
(A) (B) No mark : Without sub-base
42
02 : Rc1/8
513
(R1) (P) (R2) G2 : * G 1/8
N2 : * NPT 1/8
D25 : 2-position, double solenoid F2 : * NPTF 1/8

(A) (B) Note Valve without sub-base comes with a
42 base gasket & two mounting screws.

513 Connector position
(R1) (P) (R2) P: S:

D35 : 3-position, closed center (With indicator light (Without indicator light
and surge suppressor) and surge suppressor)
(A) (B)
42

513
(R1) (P) (R2)

E35 : 3-position, exhaust center

(A) (B)
42

513
(R1) (P) (R2)

O35 : 3-position, pressure center

(A) (B)
42

513
(R1) (P) (R2)

Voltage
1 : DC24V

Special specification
No mark: Standard (Internal pilot)

X : * External pilot

(Pilot air is exhaust
through exclusive port Y.)

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

59

ADEX VALVE

A12P Series

Optional Accessories and Spare parts

Connector with lead wire Sub-base
A05P DC CL5 A12P B 02X

Lead wire length Special specifications
5 : 500mm No mark: Standard
10 : * 1000mm
Voltage X : For external pilot
DC : For DC (Port X)

Type Port size
P : For PR type 02 : Rc1/8
G2 : * G 1/8
N2 : * NPT1/8
F2 : * NPTF1/8

For PR type DC
( ) Black

( ) Red

(Note) For common use with PR type of A05 and A12

Locking cover Base gasket
A05P LA A12PX G

Color Content of kit
A : Orange SG : Gasket & mounting screws
G : Gasket only(Pack of 10)
(Note) For common use with all A05 and A12 S : Mounting screw only (Pack of 20)

Tag for solenoid valve Special specifications
A 0 5 P N (Pack of 10) No mark : Standard

Tag X : * For external pilot(With port X)

Mounting screw

Base gasket

Solenoid valve

(Note) For common use with sub-base mounting type of
A05 and A12

* : Made to order Parker Hannifin Corporation
60 Pneumatic Division

ADEX VALVE

A12P Series

Material Specification

2-position
Single solenoid

2-position
Double solenoid

3-position
Closed center
3-position
Exhaust center
3-position
Pressure center

Main Components Material
Aluminium die-casting
No. Description
Body Aluminium/NBR
Spool ass'y Resin
End cover Resin
Piston housing Resin
Piston
Pilot valve Refer to A00 Series
Base gasket NBR
Sub-base
Aluminium die-casting
Parker Hannifin Corporation
61 Pneumatic Division

ADEX VALVE (Unit : mm)

A12P Series 16
M5 Port Y
Dimensions For model with
symbol X
A12PS25

Connector position: 18 9.5
P or S 14.5
56 6
2-φ 4.3 48 4 22 14.5 4
16 Mounting hole 40.5

23.5 Y
X
15
10

M5 Port X

For model with 500 6 93.5
symbol X
59.5 34

Manual override

61.1
57.5
49.5
33
22
9.5

5-Rc1/4 18 18
28

With locking cover

φ 9.4

5.4

Parker Hannifin Corporation
Pneumatic Division

62

ADEX VALVE (Unit : mm)

A12P Series 16
M5 Port Y
Dimensions For model with
symbol X
A12PD25

Connector position: 18 9.5
P or S 14.5
56 31.5
2-φ 4.3 48 4 22 14.5 4
16 Mounting hole 40.5
Y
23.5
X
15
10

M5 Port X 119 6 500
For model with 59.5
symbol X 500 6
Manual override
59.5

61.1
57.5
49.5
22
9.5

5-Rc 1/4 18 18
28

With locking cover

φ 9.4

5.4

Parker Hannifin Corporation
Pneumatic Division

63

ADEX VALVE (Unit : mm)

A12P Series 16
M5 Port Y
Dimensions For model with
symbol X
A12PD35, A12PE35, A12PO35

Connector position: 18 9.5
P or S 14.5
56 42.5 22 14.5 4
2- φ 4.3 48 4 40.5
16 Mounting hole Y

23.5
X
15
10

M5 Port X

For model with 500 6 130 6 500
symbol X 59.5
70.5
Manual override

61.1
57.5
49.5

22
9.5

5-Rc 1/4 18 18
28

With locking cover

φ 9.4

5.4

Parker Hannifin Corporation
Pneumatic Division

64

ADEX VALVE

5 Port pilot operated solenoid valve

A12R Series

Rubber Seal /In-line Mounting type

A12RS25 2-position
A12RD25 Single solenoid
A12RD35
A12RE35 2-position
A12RO35 Double solenoid

3-position
Closed center

3-position
Exhaust center

3-position
Pressure center

Specifications Unit A12RS25 A12RD25 A12RD35 A12RE35 A12RO35
0.15 0.7
Model No. Non-lubricated / lubricated air 12
Fluid 0.66

Port size Port 2, 4 : Rc1/8 , C6, C8

Port 1, 3, 5 : Rc 1/8

Effective area mm2 8.8 8.5
Cv value 0.48
Operating ambient temperature 0.46
600
5 50

Pressure range MPa 0.1 0.7 0.2 0.7

0.1 0.7 For external pilot operation

Maximum frequency cycle/min 500

Response ON s 0.015 0.010 0.012
time DC s 0.018 (0.024) 0.036 (0.042)

OFF

Pilot air exhaust Individual exhaust

Manual override Screwdriver-operated locking button

Mounting position m/s2 83 Free
g 150/30
Shock resistance, 101 106
vibration resistance

Mass

(Note) ● Service kit not available be supplied to prevent from freezing.
● When temperature of valve site goes down below 5 , complete dry air sh
● Pressure range of external pilot supply : 0.25 0.7MPa
● Response time in bracket ( ) shows with surge suppressor.
● Response time shown above is in accordance with JIS B 8375.
● Effective area shown above is a value between ports 1 and 2, 4.

Electrical Specifications

Rated voltage DC V 24

Permissible voltage fluctuation % 10, 10

Power DC W 0.6 (with indicator light and surge suppressor), 0.55 (without indicator light and surge suppressor)
consumption

Grade of Insulation JIS grade E
Wiring Plug-in connector
Surge suppressor
Indicator light Diode
LED

Parker Hannifin Corporation
Pneumatic Division

65

ADEX VALVE

A12R Series 1 P 01 E

Ordering Instructions Wiring
No mark: Without connector
A12R S25
E : Connector with lead wire
Function (Length : 500mm)
S25 : 2-position, single solenoid
Size of ports 2 and 4
(A) (B) 01 : Rc1/8
42 C6 : * With push-in fitting forφ 6
513 C8 : * With push-in fitting forφ 8
Note When using G, NPT, NPT
(R1) (P) (R2)
threads, consult KURODA Pneumatics Ltd.
D25 : 2-position, double solenoid Connector position
P: S:
(A) (B)
42 (With indicator light (Without indicator light
and surge suppressor) and surge suppressor)
513 Q: B:
(R1) (P) (R2)
(With indicator light (Without indicator light
D35 : 3-position, closed center and surge suppressor) and surge suppressor)

(A) (B) Voltage
42 1 : DC24V

513
(R1) (P) (R2)

E35 : 3-position, exhaust center

(A) (B)
42

513
(R1) (P) (R2)

O35 : 3-position, pressure center

(A) (B)
42

513
(R1) (P) (R2)

Special specification
No mark: standard (Internal pilot)

X : * External pilot

(Pilot air is exhaust
through exclusive port Y.)

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

66

ADEX VALVE

A12R Series

Optional Accessories and Spare parts

Connector with lead wire AB plate
A05P DC CL5 A12R AB 01X

Lead wire length Note Special specifications
5 : 500mm No mark : Standard
10 : * 1000mm
Voltage X : * For external pilot
DC : For DC
(With port X)
Type
P : For PR type Port size

01 : Rc1/8

C6 : * With push-in fitting forφ 6
C8 : * With push-in fitting forφ 8

When using G, NPT, NPT
threads, consult KURODA Pneumatics Ltd.

For PR type DC AC Mounting Mounting
( ) Black Blue screw screw

( ) Red Blue AB plate AB plate
(Tapped hole (With push-
(Note) For common use with PR type of A05 and A12 type) in fitting)

Voltage convertor with connector Plate gasket Plate gasket

Refer to page 16 for voltage convertor with connector.

Locking cover Bracket BF
A05P LA A12R
Mounting
Color F : Foot bracket
A : Orange S : Side bracket

(Note) For common use with all A05 and A12

Solenoid Mounting screw
valve

Foot bracket/F

(Note) Only single solenoid
mountable

Side bracket/S

Mounting screw

* : Made to order Solenoid valve
67 Parker Hannifin Corporation
Pneumatic Division

ADEX VALVE

A12R Series

Material Specification

2-position
Single solenoid

2-position
Double solenoid

3-position
Closed center
3-position
Exhaust center
3-position
Pressure center

Main Components Material
Aluminium die-casting
No. Description
Body Aluminium/NBR
Spool ass'y Resin
End cover Resin
Piston housing Resin
Piston
Pilot valve Refer to A00 Series
Plate gasket NBR
AB plate
Aluminium die-casting

68 Parker Hannifin Corporation
Pneumatic Division

ADEX VALVE

A12R Series (Unit : mm)

Dimensions

A12RS25

1.1 15 1.1 2-φ 3.1 36
10 (Mounting hole) 14

Push-in fitting for 2- φ6,φ 8 0.8 0.8 20 12 M3 (Port X)
(For C6, C8) 34 (For model with symbol X)
C6 : (58.3)
500 6 93.5 C8 : (63.6) 58
34
Connector position: 59.5 500 6 5 34.6

P or S

41.6
39.5
38
30
13.5
9

2-M2.5 Depth 4(Rear surface) 13.4
(Bracket mounting hole)
55
13.6 13.6
Connector position:
Q or B

5-Rc1/8or 3-Rc1/8 (For C6, C8)

With locking cover

5.4 φ 9.4 With foot bracket

With side bracket 2-φ 3.5
(Mounting hole)

1.2 38
20.3 47

29
22

44 2-φ 3.5
37 (Mounting hole)

41.5
45

38.2
1.2

Parker Hannifin Corporation
Pneumatic Division

69

ADEX VALVE

A12R Series (Unit : mm)

Dimensions

A12RD24

1.1 15 1.1 2-φ 3.1 36
10 (Mounting hole) 14

12

Push-in fitting for 2- φ 6, φ8 M3 (Port X)
(For C6, C8) (For model with symbol X)

500 6 113 6 500
59.5
59.5

Connector 58
position:
P or S C6 : (58.3) C8 : (63.6)

41.6 0.8 0.8 2034 500 6 5 34.6
39.5
38
30
13.5
9

2-M2.5 Depth 4(Rear surface) 13.4
(Bracket mounting hole)
55

Connector position:
Q or B

13.6 13.6 5-Rc1/8or 3-Rc1/8(For C6, C8)

With locking cover

φ 9.4

5.4 With side bracket

1.2

20.3

44 2- φ 3.5
37 (Mounting hole)

41.5 45

Parker Hannifin Corporation
Pneumatic Division

70

ADEX VALVE (Unit : mm)

A12R Series

Dimensions

A12RD35, A12RE35, A12RO35

18 1.1 2-φ 3.1 36
10 (Mounting hole) 14

12

1.1

Push-in fitting for 2- φ 6, φ8 M3 (Port X)
(For C6, C8) (For model with symbol X)

500 6 130 6 500
70.5
Connector 59.5

position: 58

P or S

41.6 C6 : (58.3) C8 : (63.6) 500 6 5 34.6
39.5
38 20 0.8 0.8 34
30
13.5
9

2-M2.5 Depth 4(Rear surface) 13.4
(Bracket mounting hole)
55

Connector position:
Q or B

With locking cover 13.6 13.6 5-Rc1/8or 3-Rc1/8 (For C6, C8)

φ 9.4 With side bracket

5.4

1.2

44 2-φ3.5 45 20.3
37 (Mounting hole)

41.5

Parker Hannifin Corporation
Pneumatic Division

71

ADEX VALVE

Individual wiring type manifold

MF A 1 2 P
Bar type R

MFS□ A12P Common SUP, Common EXH
Ports 2 & 4 on side

MFX□ A12P Common SUP, Common EXH
Common external pilot
Ports 2 & 4 on side

MFU□ A12R Common SUP, Common EXH
Ports 2 & 4 on valve body

Manifold Specifications

For A12P Series For A12R Series

MFS□ A12P MFX□ A12P MFU□ A12R

Type of manifold Common SUP, Common EXH Common SUP, Common EXH Common SUP, Common EXH
Pilot valve captured exhaust Common external pilot Pilot valve captured exhaust
Ports 2 & 4 on side Pilot valve captured exhaust Ports 2 & 4 on valve body
Ports 2 & 4 on side
Rc1/4
Ports 1, 3, 5 Rc1/4 Rc1/4 Rc1/4, C6, C8
Rc1/4, C6, C8 Rc1/4, C6, C8
Port size Ports 2, 4 A12RS25
Port Y M5 A05RD25
M5 A05RD35
Port X 2 20 A05RE35
Direct mount A05RO35
Number of stations
A12R-BP
Mounting

Mountable solenoid valve A12PS25 A12PS25X
A12PD25 A12PD25X
A12PD35 A12PD35X
A12PE35 A12PE35X
A12PO35 A12PO35X

Blank plate A12P-BP

Parker Hannifin Corporation
Pneumatic Division

72

ADEX VALVE

A12P, A12R Series

Ordering Instructions MFS 7 A12P 02

Manifold for A12P Series Size of ports 2 and 4
01 : Rc1/8
Type of manifold C4 : * With push-in fitting forφ 6
MFS : Common SUP, Common EXH C6 : * With push-in fitting forφ 8

Ports 2 & 4 on side (Note) When using G, NPT, NPTF
MFX : Common SUP, Common EXH threads, consult KURODA
Pneumatics Ltd.
Common external pilot
Ports 2 & 4 on side

Number of stations Mountable solenoid valve series
2 2 station A12P

20 20 station



Mountable solenoid valve For details refer to Pages 58 60. E

A12P S25 1 P

Function Wiring
S25 : 2-position, single solenoid No mark: Without connector

(A) (B) E : Connector with lead wire
42 (Length : 500mm)

513 Port size
(R1) (P) (R2) No mark: Without sub-base
(Note) A gasket & two mounting screws
D25 : 2-position, double solenoid
come with valve.
(A) (B) Connector position
42 P: S:

513 (With indicator light (Without indicator light
(R1) (P) (R2) and surge suppressor) and surge suppressor)

D35 : 3-position, closed center Voltage
1 : DC24V
(A) (B)
42

513
(R1) (P) (R2)

E35 : 3-position, exhaust center

(A) (B)
42

513
(R1) (P) (R2)

O35 : 3-position, pressure center

(A) (B)
42

513
(R1) (P) (R2)

Special specifications

No mark : Standard(Internal pilot)

X : * External pilot

(Note) External pilot valve is available only
when it is mounted on MFX.

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

73

ADEX VALVE

A12P, A12R Series

Ordering Instructions

Manifold for A12R Series

MFU 7 A12R 01

Type of manifold Size of ports 2 and 4
MFU : Common SUP, Common EXH 01 : Rc1/8
C4 : *With push-in fitting forφ 6
Ports 2 & 4 on valve body C6 : * With push-in fitting forφ 8

Number of stations (Note) When using G, NPT, NPTF
2 2 station threads, consult KURODA
Pneumatics Ltd.
20 20 station



Mountable solenoid valve series
A12R

Mountable solenoid valve For details refer to Pages 65 67.

A12R S25 1 P 01 E

Function For mounting on manifold
S25 : 2-position, single solenoid MF : For mounting on manifold
(Note) A gasket & two mounting
(A) (B)
42 screws come with valve.
Wiring
513 No mark: Without connector
(R1) (P) (R2)
E : Connector with lead wire
D25 : 2-position, double solenoid (Length : 500mm)

(A) (B) Size of ports 2 and 4
42 01 : Rc1/8
C6 : *With push-in fitting for φ 6
513 C8 : *With push-in fitting for φ 8
(R1) (P) (R2) (Note) When using G, NPT, NPTF threads,

D35 : 3-position, closed center consult KURODA Pneumatics Ltd.
Connector position
(A) (B) P: S:
42
(With indicator light (Without indicator light
513 and surge suppressor) and surge suppressor)
(R1) (P) (R2)

E35 : 3-position, exhaust center

(A) (B)
42

513
(R1) (P) (R2)

O35 : 3-position, pressure center

(A) (B)
42

513
(R1) (P) (R2)

Voltage
1 : DC24V

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

74

ADEX VALVE

A12P, A12R Series

Optional Accessories and Spare parts

Collective wiring connector AB plate
A05P DC A12R AB 01

Lead wire length Port size
5 : 500mm
10 : * 1000mm 01 : Rc1/8

Voltage C4 : * With push-in fitting forφ 6
DC : For DC C6 : * With push-in fitting forφ 8

(Note) When using G, NPT, NPTF
threads, consult KURODA Pneumatics Ltd.

Type Mounting Mounting
P : For PR type screw screw
AB plate
For PR type DC AB plate (With push-
(-)Black (Tapped hole in fitting)
(+)Red type)
Plate gasket
(Note) For common use with PR type of A05 and A12 Plate gasket

Locking cover Blank plate For A12R
A05P LA
For A12P A12R BP
Color
A : Orange A12P BP Mounting
screw
(Note ) For common use with all A05 and A12 Mounting
screw
Tag for solenoid valve
A 0 5 P N (Pack of 10) Blank plate Blank plate

Tag Base gasket Manifold
gasket

Solenoid valve Manifold gasket
A12R G
(Note) For common use with sub-base mountig type of A05,
and A12 Content of kit
SG : Gasket & mounting screws
Base gasket G : Gasket only(Pack of 10)
A12PX G S : Mounting screw only (Pack of 20)

Content of kit Mounting screw
SG : Gasket & mounting screws
G : Gasket only(Pack of 10) Manifold gasket
S : Mounting screw only (Pack of 20)
* : Made to order
Special specifications
No mark : Standard

X : * For external pilot(With port X)

Mounting screw

Base gasket

Parker Hannifin Corporation
Pneumatic Division

75

ADEX VALVE (Unit : mm)

A12P, A12R Series

DMimFSe□ns-Aio1n2Ps-02 C6, C8 , MFX□-A12P-02 C6, C8

With locking cover

5.4

φ 9.4

A12PS25(For MFS) A12PD25(For MFS)
A12PS25X(For MFX) A12PD25X(For MFX)

M5(Both side) 59.5 6 A12PD35,A12PE35,A12PO35(For MFS)
(Port X for MFX) A12PD35X,A12PE35X,A12PO35X(For MFX)

3-Rc1/4 (Both side) Blank plate A12P-BP
(Port 1,3,5)

X5 1 10.9

63.5 70.5 3Y 8.7
61 59.5 40.2
41.5 34
22 72
18.5

(3.6 : For MFX-C6) 14 M5(Both side) 6 4- φ 4.5
(14.5 : For MFX-C8) 18 (Port Y) 6 (Mounting hole)

20 P=17.5n+8.5
35 5 (P=16n+10 : For C6,C8) (5)

L=17.5n+18.5
(L=16n+20 : For C6,C8)

78.6 4
2
39.5 49.4
28 2.5 6.8 17.5
9.5 18 (16 : For C6,C8)

2n=Rc 1/4
(Push-in fitting for 2n-φ 6 : C6)
(Push-in fitting for 2n-φ 8 : C8)

(Port 2 & 4)

Parker Hannifin Corporation
Pneumatic Division

76

ADEX VALVE (Unit : mm)

A12P, A12R Series

DMimFUe□ns-Aio1n2Rs-01 C6, C8

With locking cover

5.4

φ 9.4

A12RS25 A12RD25
A12RD35,A12RE35,A12RO35
3-Rc1/4 (Both side) 59.5 6
(Port 1,3,5) 2m=Rc1/8
(Push-in fitting for 2n-φ 6 : C6)
(Push-in fitting for 2n- φ 8 : C8)
(Port 2 & 4)

Blank plate A12R-BP

19.5 19.5 77 R1 P R2 9.8 9.8
29
34
58

10.5 6 70.5 6 59.5 4-φ 4.5
18 (Mounting hole)

67.5
(86.3 : For C6)
(91.6 : For C8)

5 P=16n+10 (5)
L=16+20

69.6 37.4
27.5

18 16

Parker Hannifin Corporation
Pneumatic Division

77

ADEX VALVE

Multipin connector type manifold
P
MC A 1 2 R
Bar type

MCS□ A12P Common SUP, Common EXH
Ports 2 & 4 on side

MCX□ A12P Common SUP, Common EXH
Common external pilot
Ports 2 & 4 on side

MCU□ A12R Common SUP, Common EXH
Ports 2 & 4 on valve body

Manifold Specifications

For A12P Series For A12R Series

MCS□ A12P MCX□ A12P MCU□ A12R

Type of manifold Common SUP, Common EXH Common SUP, Common EXH Common SUP, Common EXH
Pilot valve captured exhaust Common external pilot Pilot valve captured exhaust
Ports 2 & 4 on side Pilot valve captured exhaust Ports 2 & 4 on valve body
Ports 2 & 4 on side
Rc1/4
Ports 1, 3, 5 Rc 1/4 Rc1/4 Rc1/8 , C6, C8
Rc1/4, C6, C8 Rc1/4, C6, C8
Port size Ports 2, 4 A12RS25
Port Y M5 A05RD25
M5 A05RD35
Port X 2 12 A05RE35
Direct mount A05RO35
Number of stations
A12RG-BP
Mounting

Mountable solenoid valve A12PS25 A12PS25X
A12PD25 A12PD25X
A12PD35 A12PD35X
A12PE35 A12PE35X
A12PO35 A12PO35X

Blank plate A12PG-BP

WIRING

When doing wiring work, be sure to turn off power beforehand.
For wiring instructions, refer to Pages 23 and 24.

Parker Hannifin Corporation
Pneumatic Division

78

ADEX VALVE

A12P, A12R Series

Ordering Instructions A12P 02 ML P

Manifold for A12P Series Ootion 2
DMF : With Manifold drive unit
MCS 7
No mark : Without Manifold drive unit
Type of manifold (Note) Manifold drive unit can be
MCS : Common SUP, Common EXH
mounted for ML type only.
Ports 2 & 4 on side Polarity
MCX : Common SUP, Common EXH P : NPN type
M : *PNP type
Common external pilot
Ports 2 & 4 on side Connector specification
ML : Flat cable connector
Number of stations… DL : D sub-connector
2 2 station…
Size of ports 2 and 4
12 12 station 02 : Rc1/8
Mountable solenoid valve series C6 : * With push-in fitting forφ 4
A12P C8 : * With push-in fitting forφ 6
(Note) When using G, NPT, NPTF threads,

consult KURODA Pneumatics Ltd.

Mountable solenoid valve For details refer to Pages 58 60. PS

A12P S25 1 P

Function Wiring
S25 : 2-position, single solenoid No mark: Without connector

(A) (B) PS : With connector for collective wiring
42 (For single solenoid)

513 PD : With connector for collective wiring
(R1) (P) (R2) (For double solenoid)

D25 : 2-position, double solenoid (Note) For minus common (PNP), order a
connector in addition
(A) (B)
42 Port size
No mark: Without sub-base
513 (Note) A gasket & two mounting screws
(R1) (P) (R2)
come with valve.
D35 : 3-position, closed center
Connector position
(A) (B) P: S:
42
(With indicator light (Without indicator light
513 and surge suppressor) and surge suppressor)
(R1) (P) (R2)
Voltage
E35 : 3-position, exhaust center 1 : DC24V

(A) (B) * : Made to order
42

513
(R1) (P) (R2)

O35 : 3-position, pressure center

(A) (B)
42

513
(R1) (P) (R2)

Special specifications
No mark : Standard(Internal pilot)

X : * External pilot
(Note) External pilot valve is available only when

it is mounted on MCX.

Parker Hannifin Corporation
Pneumatic Division

79

ADEX VALVE

A12P, A12R Series

Ordering Instructions A12R 01 ML P

Manifold for A12R Series Ootion 2
DMF : With Manifold drive unit
MCU 7 No mark : Without Manifold drive unit
(Note) Manifold drive unit can be
Type of manifold
MCU : Common SUP, Common EXH mounted for ML type only.

Ports 2 & 4 on valve body Polarity
P : NPN type
Number of stations… M : *PNP type
2 2 station…
Connector specification
12 12 station ML : Flat cable connector
DL : D sub-connector
Mountable solenoid valve series
A12R Size of ports 2 and 4
01 : Rc 1/8
C6 : * With push-in fitting for φ 6
C8 : * With push-in fitting for φ 8
(Note) When using G, NPT, NPTF threads,

consult KURODA Pneumatics Ltd.

Mountable solenoid valve For details refer to Pages 65 67.

A12R S25 1 P 01 PS

Function For mounting on manifold
S25 : 2-position, single solenoid MF : For mounting on manifold
(Note) A gasket & two mounting
(A) (B)
42 screws come with valve.
Wiring
513 No mark: Without connector
(R1) (P) (R2)
PS : With connector for collective wiring
D25 : 2-position, double solenoid (For single solenoid)

(A) (B) PD : With connector for collective wiring
42 (For double solenoid)

513 (Note) For minus common (PNP), order a
(R1) (P) (R2) connector in addition

D35 : 3-position, closed center Size of ports 2 and 4
01 : Rc 1/8
(A) (B) C6 : * Wi th push-in fitting for φ 6
42 C8 : * With push-in fitting for φ 8
(Note ) When using G, NPT, NPTF threads,
513
(R1) (P) (R2) consult KURODA Pneumatics Ltd.

E35 : 3-position, exhaust center Connector position
P: S:
(A) (B)
42 (With indicator light (Without indicator light
and surge suppressor) and surge suppressor)
513
(R1) (P) (R2)

O35 : 3-position, pressure center

(A) (B)
42

513
(R1) (P) (R2)

Voltage
1 : DC24V

* : Made to order Parker Hannifin Corporation
80 Pneumatic Division

ADEX VALVE

A12P, A12R Series

Optional Accessories and Spare parts

□Collective wiring connector AB plate
A12R AB 01
A12PS CC

Polarity Port size
01 : Rc1/8
No mark : NPN type C6 : * With push-in fitting forφ 6
C8 : * With push-in fitting forφ 8
Type M : * PNP type (Note) When using G, NPT, NPTF threads,
consult KURODA Pneumatics Ltd.
PS : For PR type single solenoid
PD : For PR type double solenoid

For PR type single solenoid Mounting Mounting
screw screw

For PR type double solenoid AB plate AB plate
(Tapped hole (With push-
type) in fitting)

Plate gasket Plate gasket

Locking cover Blank plate For A12R
A05P LA
For A12P A12RG BP
Color
A : Orange A12PG BP Mounting
screw
(Note) For common use with all A05 and A12 Mounting Blank plate
screw
Tag for solenoid valve Blank plate Manifold
A 0 5 P N (Pack of 10) gasket
Base
Tag gasket Blank
cover
Solenoid valve Blank
cover
(Note) For common use with sub-base mountig type of A05,
and A12. Manifold gasket
A12R G
Base gasket
A12PX G Content of kit
SG : Gasket & mounting screws
Content of kit G : Gasket only(Pack of 10)
SG : Gasket & mounting screws S : Mounting screw only (Pack of 20)
G : Gasket only(Pack of 10)
S : Mounting screw only (Pack of 20) Mounting screw

Special specifications Manifold gasket
No mark : Standard

X : * For external pilot(With port X)

Mounting screw

Base gasket

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

81

ADEX VALVE (Unit : mm)

A12P, A12R Series

DMimCeS□ns-Aio1n2sP-02 C6, C8 -DL, MCX□-A12P-02 C6, C8 -DL

With locking cover

5.4

φ 9.4

(61.5) 8.7 10.9 31.5
54.5 40.4

M5(Both side) A12PS25(For MCS)59.5 6 72A12PD25(For MCS)
(Port X for MCX) A12PS25X(For MCX) 84 3A12PD25X(For MCX)
D sub-connector(25P) A12PD35,A12PE35,A12PO35(For MCS)
3-Rc1/4 (Both side) A12PD35X,A12PE35X,A12PO35X(For MCX)
(Port 1,3,5) 23.5
Blank plate A12PG-BP

63.5 6 59.5 4.6 34 513
61
41.5 6 70.5
22
18.5

(3.6 : For C6) M5(Both side) 2-M2.6 4-φ 4.5
(14.5 : For C8) (Port Y for MCX) (Mounting hole)
5 P=17.5n+34
14 L=17.5n+44 (5)

18 4 2n=Rc1/4
20 2 (Push-in fitting for 2n- φ6 : C6)
(Push-in fitting for 2n- φ8 : C8)
35 2.5 6.8 (Port 2 & 4)
42.5 17.5
78.6 49.4
39.5
28
9.5

Parker Hannifin Corporation
Pneumatic Division

82

ADEX VALVE (Unit : mm)

A12P, A12R Series

DMimCeSn□s-Aio1n2sP-02 C6, C8 -ML , MCX□-A12P-02 C6, C8 -ML

With locking cover

5.4

φ 9.4

(73.5) 31.5
54.5

M5(Both side) A12PS25(For MCS)59.5 6 A12PD25(For MCS)
(Port X for MCX) A12PS25X(For MCX) A12PD25X(For MCX)
Flat cable connector(26P)
3-Rc1/4 (Both side) A12PD35,A12PE35,A12PO35(For MCS)
(Port 1,3,5) 23.5 A12PD35X,A12PE35X,A12PO35X(For MCX)

Blank plate A12PG-BP

4.6 5 13 8.7 10.9
40.4
63.5 34
61 72
41.5 70.5 59.5 84 3
22
18.5

(3.6 : For C6) M5(Both side) 4-φ 4.5
(14.5 : For C8) (Port Y for MCX) (Mounting hole)

14 6 (5)

18 6 2n=Rc1/8
20 (Push-in fitting for 2n- φ 6 : C6)
(Push-in fitting for 2n- φ 8 : C8)
35 (Port 2 & 4)

5 P=17.5n+34
L=17.5n+44

78.6 4

39.5 49.4
28
9.5 2

2.5 6.8

42.5 17.5

Parker Hannifin Corporation
Pneumatic Division

83

ADEX VALVE (Unit : mm)

A12P, A12R Series

DMimCeUn□s-Aio1n2sR-01 C6, C8 -DL

With locking cover

5.4

φ 9.4

(49.5) 9.8 9.8 19.5
42.5 29

59.5 6 A12RS25 A12RD2558
D sub-connector(25P) 70 3
A12RD35,A12RE35,A12RO35
23.5
2m=Rc1/8
(Push-in fitting for 2n- φ 6 : C6)
(Push-in fitting for 2n- φ 8 : C8)
(Port 2 & 4)

Blank plate A12RG-BP

3-Rc1/4 (Both side)
(Port 1,3,5)

19.5 19.5 77 2 5 13

34

10.5 (86.3 : For C6) 6 70.5 6 59.5 2-M2.6 4-φ 4.5
18 (91.6 : For C8) (Mounting hole)

5 P=17.5n+34 (5)

L=17.5n+44

69.5 37.4
27.5

42.5 17.5

Parker Hannifin Corporation
Pneumatic Division

84

ADEX VALVE (Unit : mm)

A12P, A12R Series

DMimCeUn□s-Aio1n2sR-01 C6, C8 -ML

With locking cover

5.4

φ 9.4

(49.5) 19.5
42.5

A12RS25 A12RD25

Flat cable connector(26P) A12RD35,A12RE35,A12RO35

59.5 6 2m=Rc1/8
(Push-in fitting for 2n- φ 6 : C6)
(Push-in fitting for 2n- φ 8 : C8)
(Port 2 & 4)

Blank plate A12RG-BP

3-Rc1/4 (Both side) 23.5 9.8 9.8
(Port 1,3,5) 29

19.5 19.5 77 1 5 13 58
70 3
34

10.5 (86.3 : For C6) 6 70.5 6 59.5 4- φ 4.5
18 (91.6 : For C8) (Mounting hole)

5 P=17.5n+34 (5)

L=17.5n+44

69.5 37.4
27.5

42.5 17.5

Parker Hannifin Corporation
Pneumatic Division

85

ADEX VALVE

A00S SERIES

Parker Hannifin Corporation
Pneumatic Division

86

ADEX VALVE

3 Port direct operated solenoid valve

A00S Series

Poppet Seal /Sub-base Mounting type

A00SO23 2-position
A00SC23 Single solenoid
Normal open

2-position
Single solenoid
Normal closed

Specifications Unit A00SO23 A00SC23 A00SO23J A00SC23J
0 0.5 0 0.7
Model No. mm2 Non-lubricated/lubricated air
Fluid °C
Port size MPa M3
Effective area MPa
Cv value cycle/min 0.14 0.22
Operating ambient temperature 0.008 0.012
Pressure range
5 50
Vacuum version
0 0.7 0 0.5
Maximum frequency
0.1 0.4 0.1 0.6 0.1 0.5 0.1 0.6

Port 3 → Vacuum Port 1 → Pressured air Port 3 → Vacuum Port 1 → Pressured air

Port 1 → Pressured air Port 3 → Vacuum Port 1 → Pressured air Port 3 → Vacuum

600

Response ON s 0.005
time DC s 0.005(0.01)

OFF

Manual override Screwdriver-operated locking button

Mounting position Free
150/30
Shock resistance. m/s2
vibration resistance g 12.6
g 20.6
Mass No base
With sub-base

(Note) ● Service kit not available
● When temperature of valve site goes down below 5 , complete dry air should be supplied to prevent from freezing.
● Response time in bracket ( ) shows with surge suppressor.
● Response time shown above is in accordance with JIS B 8375.
● Effective area shown above is a value between ports 1 and 2, 4.

Electrical Specifications

Rated voltage DC V 24
%
Permissible voltage fluctuation W 10, 10

Power DC 0.6 (with indicator light and surge suppresso)r, 0.91 (with indicator light and surge suppresso)r,
consumption 0.55 (without indicator light and surge suppresso)r 0.86 (without indicator light and surge suppresso)r

Grade of insulation JIS grade E
Wiring Plug-in connector
Surge suppressor
Indicator light Diode
LED
Parker Hannifin Corporation
87 Pneumatic Division

ADEX VALVE

A00S Series

Ordering Instructions

A00S O23 J 1 P M3 E

Function Wiring
O23 : Single solenoid, normal open No mark: Without connector

(A) E : Connector with lead wire
2 (Length : 500mm)

31 Port size
(P) (R) No mark : Without sub-base

C23 : Single solenoid, normal closed M3 : M3
(Note) Valve without sub-base comes with a
(A)
2 base gasket & two mounting screws.

13 Connector position
(P) (R) P: S:

Flow (With indicator light (Without indicator light
No mark : Standard type and surge suppressor) and surge suppressor)
Q: B:
J : Large flow type

Voltage
1 : DC24V

(With indicator light (Without indicator light
and surge suppressor) and surge suppressor)

Parker Hannifin Corporation
Pneumatic Division

88

ADEX VALVE

A00S Series

Optional Accessories and Spare parts

Connector with lead wire Sub-base
A05P DC CL5 A00S B M3

Lead wire length Port size
5 : 500mm M3 : M3
10 : *1000mm
Voltage
DC : For DC

DC Base gasket
( ) Black A00S G
( ) Red
(Note) For common use with PR type of A05, A12 Content of kit
and A00S SG : Gasket & mounting screws
G : Gasket only(Pack of 10)
Locking cover S : Mounting screw only (Pack of 20)
A05P LA
Mounting screw
Color
A : Orange Base gasket

(Note) For common use with all A05, A12 and A00S

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

89

ADEX VALVE

A00S Series

Material Specification

Main Parts Material
Resin
No. Description ―
Body
Solenoid coil Stainless
Core Stainless/NBR
Armature ass'y
Return spring Stainless
Valve seat NBR
Base gasket NBR
Sub-base
Aluminium alloy

Parker Hannifin Corporation
Pneumatic Division

90

ADEX VALVE

A00S Series (Unit : mm)

DAim00eSnOs2io3-n□sP S , A00SC23-□P S

8.2

2-φ 2.7 220 4.5
(Mounting hole) 212 4.5 5 7.5 2.5

25.4 10.5

18.9

9.5 9.2

5 6 500 With locking cover

5.4

Manual override

28.2 φ 9.4
23.2
9.7 13
7
3 3-M3
4.4 0.4

A00SO23-□Q B , A00SC23-□Q B (Unit : mm)

8.2

32 2-φ 2.7 20
28.7 (Mounting hole) 12 4.5
28.2
23.2500 630.4 10.5 With locking cover
9.7
7 9.5 9.2 5.4
3
Manual override
5 7.5 2.5 4.5
φ 9.4

13 Parker Hannifin Corporation
3-M3 Pneumatic Division

4.4 0.4

91

ADEX VALVE

Individual Wiring type manifold

MFS A00S

Bar type

MFS□ A00S Common SUP, Common EXH
Port 2 on side

Manifold Specifications MFS□ A00S

Type of manifold Common SUP, Common EXH
Port 2 on side

Port size Port 1, 3 M5
Port 2 M3, M5
2 20
Number of stations Direct mount

Mounting

Mountable solenoid valve A00SO23, A00SO23J
A00SC23, A00SC23J

Blank plate A00S-BP

(Note) A00SO23 ( J ) cannot be mounted on the same manifold together with A00SC23 ( J ).

Parker Hannifin Corporation
Pneumatic Division

92

ADEX VALVE

A00S Series

Ordering Instructions

Manifold for A00S Series

MFS 7 A00S M3

Type of manifold Size of port 2
MFS : Common SUP, Common EXH M3 : M3

A port on side Mountable solenoid valve series
A00S
Number of stations
2 2 station (Note) A00SO23 (J ) cannot be mounted on the
20 20 station same manifold together with A00SC23 (J ).



Mountable solenoid valve For details refer to Pages 87 89. E

A00S O23 J 1 P

Function Wiring
O23 : Single solenoid, normal open No mark: Without connector

(A) E : Connector with lead wire
2 (Length : 500mm )

31 Port size
(P) (R) No mark : Without sub-base
(Note) A gasket & two mounting screws
C23 : Single solenoid, normal closed
come with a valve.
(A)
2 Connector position
P: S:
13
(P) (R) (With indicator light (Without indicator light
and surge suppressor) and surge suppressor)
Flow Q: B:
No mark : Standard type

J : Large flow type

Voltage
1 : DC24V

(With indicator light (Without indicator light
and surge suppressor) and surge suppressor)

Parker Hannifin Corporation
Pneumatic Division

93

ADEX VALVE Base gasket
A00S G
A00S Series
Content of kit
Optional Accessories Spare parts SG : Gasket & mounting screws
G : Gasket only(Pack of 10)
Connector with lead wire S : Mounting screw only (Pack of 20)
A05P DC CL5
Mounting screw
Lead wire length
5 : 500mm Base gasket

10 : * 1000mm Blank plate
A00S BP
Voltage
DC : For DC Mounting screw

DC Blank plate
( ) Black
( ) Red Plate gasket
(Note) For common use with PR type of A05, A12
and A00S

Locking cover
A05P LA

Color
A : Orange

(Note) For common use with all A05, A12 and A00S

* : Made to order

Parker Hannifin Corporation
Pneumatic Division

94

ADEX VALVE (Unit : mm)

A00S Series
DMimFSe□ns-Aio0n0Ss-M3

Connector position : Connector position :
Q or B P or S

2-M5 (Both side) (Note) A00SO23 (J ) cannot be mounted on the same
(Port 1, 3) manifold together with A00SC23 (J ).

6 500 2-φ 3.2 A00SC23(J ) or A00SO23(J )
(Mounting hole)

Blank plate A00S-BP

25.4 25.4 13
30.4

18 8
8 13

22.5

25.5 9.2 5 9.2 2.5 P 10.5n 6.5 2.5
30.5 25.5
34 30.5 L (10.5n 11.5) 3
35.5
6 500

With locking cover Port 2 : M3

φ 9.4 12 2 16.4
9

0.6 n-M3

5.4 11 10.5 (Port 2)

Port 2 : M5

8 2

0.6 n-M5
11 10.5 (Port 2)

Parker Hannifin Corporation
Pneumatic Division

95

ADEX VALVE

Manifold Specifications

Parker Hannifin Corporation
Pneumatic Division

96

ADEX VALVE

INDIVIDUAL WIRING TYPE/MFC Date of issue ..

MANIFOLD Your company name Set (s ) Date of delivery
SPECIFICATIONS Person in charge
Specification No. (Note) * : Made to order
(Duplicate this page and fill in this form). Order No.
Quantity

Type of manifold

Write a mark of circle in□ at the head of the type of manifold to be used and fill in this form.

PR type MFC A05P

Number of stations Size of ports 2 and 4 Bracket
2 2 station
20 20 station M5 ○ No mark : Without bracket
… C4 B : With bracket
… C6
CZ (Note) Bracket can be mounted only when
A05PS25 alone is mounted.

(Note) CZ : For use with tubes of different diameter

Type of mountable solenoid valve

Fill in blanks for type of solenoid valve.

A05P Voltage Wiring
1 : DC24V
Function NPN type
P : With indicator light and surge suppressor
S : Without indicator light and surge suppressor

* PNP type (Only GF type)

M : With indicator light and surge suppressor
J : Without indicator light and surge suppressor

Number of stations

Specify the type and arrangement of solenoid valve to be mounted by a mark of circle. Number of stations

Standard manifold is so designed that all ports open.

When plugging a port, specify the intended place to be plugged by writing"× " in the
column of port specification.

When using tubes of different diameter on the same manifold, specify the required

size by writing a symbol C4 or C6 in the column of port specification.

Number of stations for manifold 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity
S25
Single solenoid D25
D35
Mounted Double solenoid E35
solenoid Closed center O35
valve Exhaust center

Pressure center

Blank plate

Port specification Port 2
Port 4

For factory use For sales department use

Control No. Approved by : Checked by : Received by: Manufacture No. Approved by : Person in charge

Parker Hannifin Corporation
Pneumatic Division

97

ADEX VALVE

INDIVIDUAL WIRING TYPE/MFS,MFX Date of issue ..

MANIFOLD Your company name Set(s) Date of delivery
SPECIFICATIONS Person in charge
Specification No. (Note) * : Made to order
(Duplicate this page and fill in this form). Order No.
Quantity

Type of manifold

Write a mark of circle in□ at the head of the type of manifold to be used and fill in this form.

PR type MF A P Bracket
No mark : Without bracket

Special specifications B : With bracket
S : Standard Size of ports 2 and 4 (Note) Bracket can be mounted only
X : Common external pilot
Mountable solenoid 05 12 20 when A05PS25 alone is mounted.
Number of stations
2 2 station Value series 01 ○ (Note) C4 and C6 of A05 series can be applied
A05 Series
20 20 station A12 Series 02 ○ ○ to MFX alone.

C4 * CZ : For use with tubes of different
C6 * * diameter
… C8 **
… When using G, NPT, NPTF threads,
* consult KURODA Pneumatics Ltd.
C10 **

CZ *

Type of mountable solenoid valve Wiring

Fill in blanks for type of solenoid valve. NPN type
P : With indicator light and surge suppressor
AP S : Without indicator light and surge suppressor

* PNP type (Only GF type)

M : With indicator light and surge suppressor
J : Without indicator light and surge suppressor

Solenoid valve series Function Voltage
1 : DC24V
A05 : Series Special specifications
A12 : Series (Note) X is used only when solenoid
No mark : Standard valve is mounted on manifold
X : External pilot for common external pilot.

Number of stations

Specify the type and arrangement of solenoid valve to be mounted by a mark of circle. Number of stations →

Standard manifold is so designed that all ports open.

When plugging a port, specify the intended place to be plugged by writing" " in the

column of port specification.

When using tubes of different diameter on the same manifold, specify the required

size by writing a symbol C4, C6, C8 or C10 in the column of port specification.

Number of stations for manifold 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity
S25
Single solenoid D25
D35
Mounted Double solenoid E35
solenoid Closed center O35
valve Exhaust center

Pressure center

Blank plate

Port specification Port 2
Port 4

For factory use For sales department use

Control No. Approved by : Checked by : Received by: Manufacture No. Approved by : Person in charge

Parker Hannifin Corporation
Pneumatic Division

98

ADEX VALVE

INDIVIDUAL WIRING TYPE/MFU Date of issue ..

MANIFOLD Your company name Set(s) Date of delivery
SPECIFICATIONS Person in charge
Specification No. (Note) * : Made to order
(Duplicate this page and fill in this form). Order No.
Quantity

Type of manifold

Write a mark of circle in□ at the head of the type of manifold to be used and fill in this form.

PR type MFU AR

Number of stations Mountable solenoid valve series Size of ports 2 and 4

2 2 station A05 Series 05 12
20 20 station A12 Series M5 ○ ○
… 01
… (Note) When using G. NPT, NPTF 02 *
threads, consult KURODA Pneumatics Ltd. *
C4 *
C6 *

C8
C10

Type of mountable solenoid valve

Fill in blanks for type of solenoid valve.

AR Wiring

Solenoid valve series Function Voltage NPN type
1 : DC24V P : With indicator light and surge suppressor
A05 Series S : Without indicator light and surge suppressor
A12 Series
M : With indicator light and surge suppressor
J : Without indicator light and surge suppressor

Number of stations

Specify the type and arrangement of solenoid valve to be mounted by a mark of circle. Number of stations →
Standard manifold is so designed that all ports open.

When plugging a port, specify the intended place to be plugged by writing" ×" in the
column of port specification.

Number of stations for manifold 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity
S25
Single solenoid D25
D35
Mounted Double solenoid E35
solenoid Closed center O35
valve Exhaust center

Pressure center

Blank plate

Port specification Port 2
Port 4

For factory use For sales department use

Control No. Approved by : Checked by : Received by: Manufacture No. Approved by : Person in charge

Parker Hannifin Corporation
Pneumatic Division

99

ADEX VALVE

MULTIPIN CONNECTOR TYPE/MCC Date of issue ..

MANIFOLD Your company name Set(s) Date of delivery
SPECIFICATIONS Person in charge
Specification No. (Note) * : Made to order
(Duplicate this page and fill in this form). Order No.
Quantity

Type of manifold

Write a mark of circle in□ at the head of the type of manifold to be used and fill in this form.

PR type MCC A05P

Number of stations Size of ports 2 and 4 Connector specification Polarity
2 2 station P : NPN type
M5 ○ DL : D sub-connector
12 12 station M : * PNP type
… C4 * ML : Flat cable connector
… *(Note) : Made to order

C6 *
CZ *

(Note) CZ : For use with tubes of different diameter

Type of mountable solenoid valve

Fill in blanks for type of solenoid valve.

A05P Voltage Wiring
1 : DC24V
Function NPN type
P : With indicator light and surge suppressor
S : Without indicator light and surge suppressor
M : With indicator light and surge suppressor
J : Without indicator light and surge suppressor

Number of stations Number of stations

Specify the type and arrangement of solenoid valve to be mounted by a mark of circle.
Standard manifold is so designed that all ports open.
When plugging a port, specify the intended place to be plugged by writing"×" in the
column of port specification.
When using tubes of different diameter on the same manifold, specify the required
size by writing a symbol C4 or C6 in the column of port specification.

Number of stations for manifold 1 2 3 4 5 6 7 8 9 10 11 12 Quantity

Single solenoid S25

Mounted Double solenoid D25
solenoid Closed center D35
valve Exhaust center E35

Pressure center O35

Blank plate

Port specification Port 2
Port 4

For factory use For sales department use

Control No. Approved by : Checked by : Received by: Manufacture No. Approved by : Person in charge

100 Parker Hannifin Corporation
Pneumatic Division