QLASSIC SLIDE

QLASSIC SLIDE

Correct use of Assessment Tools

1.1m ≤ x ≤ 1.0m

Tapping Rod

QLASSIC tapping rod to check
for hollowness on wall or floor.
Also used to check for lippage
between two tiles on the floor or
wall.

152

Correct use of Assessment Tools

QLASSIC L-Square and Steel wedge also used
to measure lippage between two tiles on floor and
wall. The allowable tolerance is <1mm.

153

Correct use of Assessment Tools

Steel Wedge (0-6mm)

To measure the gaps between door leaf and floor
finishes. The allowable tolerance is <5mm..

154

Correct use of Assessment Tools

Angle Mirror

angle mirror to check the paintwork on top &
bottom of door leaf.

155

Correct use of Assessment Tools

Sprit Level 1.2m

Steel wedge

spirit level (1.2m) & steel wedge
to measure evenness of wall
surface or floor surface (tolerance
in CIS 7: <3mm/ 1.2m).

156

Correct use of Assessment Tools

steel wedge

L-square

L-square (300x200mm) & steel wedge: walls to meet at right
angle (tolerance in CIS 7: <4mm over 300mm).

157

Correct use of Assessment Tools

QLASSIC Spirit Level (1.2m length) used to check the variance in
lengths of treads and risers for staircase must not exceeding 5mm
from dimensions specified in the approved drawings.

158

Correct use of Assessment Tools

Check floor in wet areas to proper falls
using spirit level

159

Assessment Form:

Verify Compliance

verify compliance of constructed
elements against the standards

requirement

no

NA/ blank Comply X

unable to carry out assessment or yes
not available

/

160



Topic 5:

SCORE
CALCULATION
MODULE 1:

| ARCHITECTURAL WORKS
| BASIC M&E FITTINGS
| EXTERNAL WORK

162

Weightage Allocation:

Component and Building Category

Residential Building Non Residential Building ❑ Weightage for each component
or sample location is allocated
Category C Category D & distributed according to its
Category Category aesthetic consideration & cost
Component A B (Public (Public proportion.
Structural works
(Landed (Stratified /Commerci /Commerci
housing) housing)
al/Industrial al/Industria ❑ If a component is excluded
from the assessment, the
15% 20% building) l building) weightage of that component
20% 20% will be pro-rated.

Architectural works 70% 60% 55% 50%

M&E works 5% 10% 15% 20%

External works 10% 10% 10% 10%

Total Score 100% 100% 100% 100%

Refer CIS 7:2014,Table 1 (Page 4)

163

Weightage Allocation: Modified Weightage

Components Category A Category B Category C Category D
(Landed (Stratified (Public (Public
housing) housing)
/Commercial/ /Commercial/
Architectural 85.89 82.87 Industrial Industrial
Works (%) 1.84 building) building)
12.27
Basic M&E Fitting 82.24 80.00
(%) 100
3.32 2.81 4.00
External Works
(%) 13.81 14.95 16.00

Total or QLASSIC 100 100 100
Score (%)

116644

QLASSIC Score ?

Score Calculation Formula

Elements Score (%)
= (total no. of compliance ÷ total no. of check)

X weightage of each element

116655

166

QLASSIC Score

Formula 1:

Architectural Works Elements Score (%)
= (no. of compliance ÷ no. of check) X weightage of every element

Formula 2:
Architectural Works Component Score (%)
= total score for all architectural works elements X weightage

Formula 3:
External Works or Basic M&E Fittings Component Score (%)
=(no. of compliance ÷ no. of check) X weightage of every component

Formula 4:

Total Score or QLASSIC Score (%) = total score for all components

167