Correct use of Assessment Tools
1.1m ≤ x ≤ 1.0m
Tapping Rod
QLASSIC tapping rod to check
for hollowness on wall or floor.
Also used to check for lippage
between two tiles on the floor or
wall.
152
Correct use of Assessment Tools
QLASSIC L-Square and Steel wedge also used
to measure lippage between two tiles on floor and
wall. The allowable tolerance is <1mm.
153
Correct use of Assessment Tools
Steel Wedge (0-6mm)
To measure the gaps between door leaf and floor
finishes. The allowable tolerance is <5mm..
154
Correct use of Assessment Tools
Angle Mirror
angle mirror to check the paintwork on top &
bottom of door leaf.
155
Correct use of Assessment Tools
Sprit Level 1.2m
Steel wedge
spirit level (1.2m) & steel wedge
to measure evenness of wall
surface or floor surface (tolerance
in CIS 7: <3mm/ 1.2m).
156
Correct use of Assessment Tools
steel wedge
L-square
L-square (300x200mm) & steel wedge: walls to meet at right
angle (tolerance in CIS 7: <4mm over 300mm).
157
Correct use of Assessment Tools
QLASSIC Spirit Level (1.2m length) used to check the variance in
lengths of treads and risers for staircase must not exceeding 5mm
from dimensions specified in the approved drawings.
158
Correct use of Assessment Tools
Check floor in wet areas to proper falls
using spirit level
159
Assessment Form:
Verify Compliance
verify compliance of constructed
elements against the standards
requirement
no
NA/ blank Comply X
unable to carry out assessment or yes
not available
/
160
Topic 5:
SCORE
CALCULATION
MODULE 1:
| ARCHITECTURAL WORKS
| BASIC M&E FITTINGS
| EXTERNAL WORK
162
Weightage Allocation:
Component and Building Category
Residential Building Non Residential Building ❑ Weightage for each component
or sample location is allocated
Category C Category D & distributed according to its
Category Category aesthetic consideration & cost
Component A B (Public (Public proportion.
Structural works
(Landed (Stratified /Commerci /Commerci
housing) housing)
al/Industrial al/Industria ❑ If a component is excluded
from the assessment, the
15% 20% building) l building) weightage of that component
20% 20% will be pro-rated.
Architectural works 70% 60% 55% 50%
M&E works 5% 10% 15% 20%
External works 10% 10% 10% 10%
Total Score 100% 100% 100% 100%
Refer CIS 7:2014,Table 1 (Page 4)
163
Weightage Allocation: Modified Weightage
Components Category A Category B Category C Category D
(Landed (Stratified (Public (Public
housing) housing)
/Commercial/ /Commercial/
Architectural 85.89 82.87 Industrial Industrial
Works (%) 1.84 building) building)
12.27
Basic M&E Fitting 82.24 80.00
(%) 100
3.32 2.81 4.00
External Works
(%) 13.81 14.95 16.00
Total or QLASSIC 100 100 100
Score (%)
116644
QLASSIC Score ?
Score Calculation Formula
Elements Score (%)
= (total no. of compliance ÷ total no. of check)
X weightage of each element
116655
166
QLASSIC Score
Formula 1:
Architectural Works Elements Score (%)
= (no. of compliance ÷ no. of check) X weightage of every element
Formula 2:
Architectural Works Component Score (%)
= total score for all architectural works elements X weightage
Formula 3:
External Works or Basic M&E Fittings Component Score (%)
=(no. of compliance ÷ no. of check) X weightage of every component
Formula 4:
Total Score or QLASSIC Score (%) = total score for all components
167
QLASSIC REPORT
168
QLASSIC CERTIFICATE
169