The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by janet.niemi, 2017-05-24 19:54:15

The Rheem PHB 2017 flipbook version

The Rheem PHB 2017 flipbook version

Gas Continuous Flow

Scan code for
details & installation

instructions

65

66

Rheem 12L 1-2 Outdoor
876612, 874612
PEOPLE INSTALLATION

Features & Benefits

UÊ 12 L/min continuous hot water
delivery @ 25oC rise

ENERGSYTEAFRFICIENT UÊ Remote Temperature Controller
options

UÊ Accessories: Pipe cover 299841,
Recess Box 299842, 299842/WA
Security Cage 299867

UÊ 50°C models available, requiring no
tempering valve3

UÊ LED display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ 10 year heat exchanger warranty1

350
90 MOUNTING

HOLES

592 592
560
520
490

54

HOT WATER GAS 53 57
OUTLET CONNECTION 10

COLD WATER 16
INLET 163

126 125 POWER LEAD CONNECTION
43 GAS CONNECTION

HOT WATER 164
OUTLET 43 45

51 CL COLD WATER INLET

MODEL 876612 Scan code for
874612 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.7 instructions
Max Water Supply Pressure (kPa) 94
Min Water Supply Pressure (kPa) 1000 67
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
16

Rheem Standard Flue Diverter Outdoor
299881 - suitable for 12L/16L
INSTALLATION

Features & Benefits

UÊ Enables compliance with relevant
national and local regulations for
installation in covered open areas.*

UÊ Suitable for Rheem 12L or
Rheem Metro 16L

UÊ Offers added flexibility in installation

UÊ Fits simply to the water heater

UÊ Natural gas model

UÊ Suitable for installation with
Recess Box 299842, 299842/WA
Pipe Cover 299841

5 24

262
379 160

520

350

*Confirm with your local authorities that the installation
complies with all regulations applicable in your area.

PART 299881

To suit models:
876612NF, 874612NF
876E16NF, 874E16NF

68

Rheem Metro 16L 1-3 Outdoor
876E16, 874E16
PEOPLE INSTALLATION

Features & Benefits

UÊ 16 L/min continuous hot water
delivery @ 25oC rise

ENERGSYTEAFRFICIENT UÊ 60ºC hot water for kitchen and
laundry

UÊ 50ºC models provide added safety

UÊ Remote Temperature Controller
options for added convenience and
safety

UÊ LED display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ 10 year heat exchanger warranty¹

350
90 MOUNTING

HOLES

592 592
560
520
490

54

HOT WATER GAS 53 57
OUTLET CONNECTION 10

COLD WATER 16
INLET 163

126 125 POWER LEAD CONNECTION
43 GAS CONNECTION

HOT WATER 164
OUTLET 43 45

51 CL COLD WATER INLET

MODEL 876E16 Scan code for
874E16 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.7 instructions
Max Water Supply Pressure (kPa) 126
Min Water Supply Pressure (kPa) 1000 69
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
16

Rheem 20L 2-4 Outdoor
876620, 874620
PEOPLE INSTALLATION

Features & Benefits

UÊ 20 L/min continuous hot water
delivery @ 25oC rise

ENERGSYTEAFRFICIENT UÊ Remote Temperature Controller
options

UÊ 50°C models available, requiring no
tempering valve3

UÊ LED display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ Accessories: Pipe Cover 299841,
Recess Box 299842, 299842/WA
Security Cage 299867

UÊ 10 year heat exchanger warranty1

350
90 MOUNTING

HOLES

592 592
560
520
490

54

HOT WATER GAS 53 57
OUTLET CONNECTION 10

COLD WATER 16
INLET 163

126 125 POWER LEAD CONNECTION
43 GAS CONNECTION

HOT WATER 164
OUTLET 43 45

51 CL COLD WATER INLET

MODEL 876620 Scan code for
874620 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.7 instructions
Max Water Supply Pressure (kPa) 153
Min Water Supply Pressure (kPa) 1000
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
70 16

Rheem Metro Plus 24L 4-5 Outdoor
875E24, 871E24
PEOPLE INSTALLATION

Features & Benefits

UÊ 24 L/min continuous hot water
delivery @ 25oC rise

ENERGSYTEAFRFICIENT UÊ Remote Temperature Controller
options

UÊ 50°C models available, requiring no
tempering valve3

UÊ Digital display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ Accessories: Pipe Cover 299848,
Recess Box 299842, 299842/WA,
Security Wall Mounting 299868,
Security Cage 299867

UÊ 10 year heat exchanger warranty1

MOUNTING 350
HOLES 90 19

44

605 562 647
565

HOT WATER GAS 50 65
OUTLET CONNECTION
POWER 132 COLD 10
17 16
CONNECTION 92 WATER INLET
21 205
HOT WATER
OUTLET GAS INLET

127 112 53 103

COLD CL

WATER INLET

MODEL 875E24 Scan code for
871E24 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.7 instructions
Max Water Supply Pressure (kPa) 188
Min Water Supply Pressure (kPa) 1000 71
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
19

Rheem 24L 4-5 Outdoor
875624, 871624
PEOPLE INSTALLATION

Features & Benefits

UÊ 24 L/min continuous hot water
delivery @ 25oC rise

ENERGSYTEAFRFICIENT UÊ Flamesafe® overheat protection

UÊ Remote temperature controller
options

UÊ 50°C models available, requiring no
tempering valve3

UÊ Digital display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ 10 year heat exchanger warranty1

MOUNTING 350 647
HOLES 90 19

605 44
565
562

HOT WATER GAS 50 65
OUTLET CONNECTION
POWER 132 COLD 10
17 16
CONNECTION 92 WATER INLET
21 205
HOT WATER
OUTLET GAS INLET

127 112 53 103

COLD CL

WATER INLET

MODEL 875624 Scan code for
871624 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.7 instructions
Max Water Supply Pressure (kPa) 188
Min Water Supply Pressure (kPa) 1000
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
72 21

Rheem Metro Plus 24L 4-5 Outdoor
Standard Flue Diverter
875E24NF-FD PEOPLE INSTALLATION

Features & Benefits

UÊ Enables compliance with relevant
national and local regulations for
installation in covered open areas.*

UÊ Adjustable to deliver 50OC at the
nearest tap

UÊ Recess Box available -299842 to set
water heater into the wall. Compatible
with flue diverter.

UÊ Digital display for easy fault diagnosis
and service

UÊ Natural gas model

UÊ 10 year heat exchanger warranty¹

33

379 305
350 205

119 137

*Confirm with your local authorities that the installation
complies with all regulations applicable in your area.

MODEL 875E24NF-FD

Min. Operating Flow rate (L/min) 2.7 Scan code for
Nom. Gas Consumption (MJ/hr) 188 details & installation
Max Water Supply Pressure (kPa) 1000
Min Water Supply Pressure (kPa) 140 instructions
Water Connections R3/4
Gas Connection R3/4 73
Approx. Weight (Empty) kg 19

Rheem Metro Plus 24L 4-5 Outdoor
Extended Flue Diverter
875E24NF-FE PEOPLE INSTALLATION

Features & Benefits

UÊ Enables compliance with relevant
national and local regulations for
installation in covered open areas.*

UÊ Digital display for easy fault diagnosis

UÊ Natural gas model

UÊ 10 year heat exchanger warranty¹

no greater than 695 Edge of
350 balcony

591

938 66 305
350 205
Edge of
565 balcony

119 137

*Confirm with your local authorities that the installation
complies with all regulations applicable in your area.

MODEL 875E24NF-FE

Min. Operating Flow rate (L/min) 2.7 Scan code for
Nom. Gas Consumption (MJ/hr) 188 details & installation
Max Water Supply Pressure (kPa) 1000
Min Water Supply Pressure (kPa) 140 instructions
Water Connections R3/4
Gas Connections R3/4
Approx. Weight (Empty) kg 19

74

Rheem Metro Max 26L 4-5 Outdoor
875E26, 871E26
PEOPLE INSTALLATION

Features & Benefits

UÊ 26 L/min continuous hot water
delivery @ 25oC rise

ENERGSYTEAFRFICIENT UÊ Remote Temperature Controller
options

UÊ 50°C models available, requiring no
tempering valve3

UÊ Digital display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ Accessories: Pipe Cover 299848,
Recess Box 299842, 299842/WA,
Security Wall Mounting 299868,
Security Cage 299867

UÊ 10 year heat exchanger warranty1

MOUNTING 350
HOLES 90 19

44

605 562 647
565

HOT WATER GAS 50 65
OUTLET CONNECTION
POWER 132 COLD 10
17 16
CONNECTION 92 WATER INLET
21 205
HOT WATER
OUTLET GAS INLET

127 112 53 103

COLD CL

WATER INLET

MODEL 875E26 Scan code for
871E26 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.7 instructions
Max Water Supply Pressure (kPa) 199
Min Water Supply Pressure (kPa) 1000 75
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
21

Rheem 27L 4-6 Outdoor
876627, 874627
PEOPLE INSTALLATION

Features & Benefits

UÊ 27 L/min continuous hot water
delivery @ 25oC rise

UÊ Remote Temperature Controller

ENERGSYTEAFRFICIE NT options for added convenience and
safety

UÊ 50°C models available, requiring no
tempering valve3

UÊ Digital display for easy fault diagnosis

UÊ Natural gas & Propane models

UÊ 10 year heat exchanger warranty1

351 669
269
90 17

42

669 601

54

POWER LEAD 132 127 226
CONNECTION
HOT WATER GAS
CONNECTION
OUTLET
227
84 64 97

28 COLD WATER INLET

CL

MODEL 876627 Scan code for
874627 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.0 instructions
Max Water Supply Pressure (kPa) 205
Min Water Supply Pressure (kPa) 1000
Water Connections 140
Gas Connection R3/4
Approx. Weight (Empty) kg R3/4
76 24

Rheem 27L Internal 4-6 Indoor
866627, 864627
PEOPLE INSTALLATION

Features & Benefits

UÊ 27 L/min continuous hot water
delivery @ 25oC rise

UÊ Remote Temperature Controller

ERGSYTEAFRFICIE options for added convenience and
safety
EN NT

38UÊ Rheem co-axial flue system
53
UÊ 50°C models available, requiring no
tempering valve3

UÊ Digital display for easy fault diagnosis

UÊ Natural gas model

UÊ 10 year heat exchanger warranty1

351 240
331 131

Ø127

17

763 650
707

49

HOT WATER OUTLET GAS 21 10 to 40
POWER LEAD CONNECTION
CONNECTION

COLD WATER INLET

POWER LEAD 132 127 GAS
CONNECTION
CONNECTION 5

HOT WATER 28 240
OUTLET 119
CL
107 86

COLD WATER
INLET

MODEL 866627 Scan code for
864627 details & installation
Min. Operating Flow rate (L/min)
Nom. Gas Consumption (MJ/hr) 2.0 instructions
Max Water Supply Pressure (kPa) 205
Min Water Supply Pressure (kPa) 1000 77
Water Connections 140
Gas Connections R3/4
Approx. Weight (Empty) kg R3/4
24

Rheem Continuous Flow Flue Components
Suitable for 866627, 864627, 862627

295116 Horizontal Terminal 295117 Vertical Terminal

227 Ø233
97 Ø208

Ø127 Ø76 140
300 260

295118 90° Bend

Ap2p5r5ox Approx 400
Ap1p9r2ox Ap5p0r0oAxp3p8r0ox

Ap2p0r7ox

Ap2p7r0ox

295119 45° Bend 400

260

210 280Ap1p5r3ox

PART DESCRIPTION WHERE USED

295116 Horizontal Terminal Required where flue terminates horizontally

295117 Vertical Terminal Required where flue terminates vertically

295118 90º Bend Maximum of 3 per installation

295119 45º Bend Maximum of 6 per installation (with no 90º
bends)

Rheem INTERNAL Continuous Flow Water Heater must only be installed
using certified Rheem coaxial flue components. Do not use any other
type of flue system. Carefully follow the installation instructions.
78

Rheem Continuous Flow Flue Components
Suitable for 866627, 864627, 862627

295122 – Straight 295123 FF
Length 900mm Adapter

213

887 295124 MM
Adapter

187

295125 Trim Ring 295126 Straight Length
300mm
Ø230
Ø133 277

PART DESCRIPTION WHERE USED

295122 Straight Length 900mm Long straight sections

295123 Female Female Adapter Required to reverse flue pipe direction to
allow condensate to drain away correctly
from water heater in long horizontal sections
of horizontally terminating flues

295124 Male Male Adapter Required to reverse flue pipe direction to
allow condensate to drain away correctly
from water heater in long horizontal sections
of horizontally terminating flues

295125 Trim Ring (optional) Conceal internal and/or external hole in wall
or ceiling terminating flues

295126 Straight Length 300mm Short straight sections

Rheem INTERNAL Continuous Flow Water Heater must only be installed
using certified Rheem coaxial flue components. Do not use any other
type of flue system. Carefully follow the installation instructions.

79

Rheem Continuous Flow Flue Components
Suitable for 866627, 864627, 862627

295127 – Adjustable
Straight 560 – 890mm

890
MAX
560
MIN

295129 – Bracket

145 180

Ø127 295139
25 Condensate Trap

PART DESCRIPTION WHERE USED
295127 Adjustable Length 560 –
890mm Allows to trim flue to exact length required
Support flue at intervals not exceeding 2m
295129 Bracket and after any bend
Required with every condensate drain. Can
295139 Condensate Trap be connected to a common waste

Rheem INTERNAL Continuous Flow Water Heater must only be installed
using certified Rheem coaxial flue components. Do not use any other
type of flue system. Carefully follow the installation instructions.
80

Rheem Continuous Flow Flue System
Typical Internal Flue Installation

Refer to Rheem Owner’s Guide and Installation Instruction for
details.

Horizontal termination to adjacent wall

13.5m MAXIMUM LINEAL LENGTH*
SUBTRACT 1.5M PER 90˚ BEND OR 0.75m PER 45˚ BEND

295124 295127 295122 295123 295116

295118 SLOPE 295125
20mm
295126/
295122/ 1000mm
295127

Direct Vent Horizontal Wall Direct Vent Vertical Termination

295118 295126 295116 VERTICAL
TERMINAL
295117

295125 FLASHING
(optional)
(not supplied)

13.5m MAXIMUM*
295122

295126

295139

* Note: Maximum flue length with no bends is 13.5m. Reduce
the maximum length by 1.5m for every 90° bend and reduce the
maximum length by 0.75m for every 45° bend.

Flue termination must comply with the requirements of
AS/NZS 5601.1

81

Controllers
Rheem Standard and Deluxe Electronic
Temperature Controllers

Features & Benefits
UÊ Suitable for all Rheem Continuous Flow models
UÊ Allows you to choose the desirable hot water temperature
UÊ Standard or Deluxe models
UÊ Deluxe controllers offer a “bath fill’ mode to turn off the water

flow once the bath is filled
Temperature Controller with cable
299850 - Kitchen
299851 - Bathroom 1
299852 - Bathroom 2

Deluxe Temperature Controller with
cable
299858 - Kitchen
299859 - Bathroom 1
299860 - Bathroom 2

Controllers and cable also available separately

82

Rheem EZ Link®
290141

Features & Benefits

UÊ Suitable for use with all Rheem 12,16,
20 and 27 L/min Continuous Flow gas
water heater models

UÊ Flexible delivery of up to 54 L/min

UÊ Staged heating, so energy usage
corresponds only to the hot water
demand

UÊ 2 units means no loss of hot
water supply in the event of a unit
breakdown

UÊ Optional remote controller for
temperature control, easy fault
diagnosis and service

MODEL 290141 Scan code for
details & installation
Suitable for Rheem 12,16, 20 and 27 L/min
models instructions

Refer to EZ Link Owner’s Guide and 83
Installation Instructions for the set up
procedure.

Rheem Security Cage
299867

Rheem Security Cage for use with all Rheem continuous flow gas
water heater models.
The kit contains:
1. Security cage
2. Top mounting bracket
3. Bottom mounting bracket
4. Securing fasteners

600 2
508 261 4

1

1030

3

565

84

Rheem Security Wall Bracket
299868

Suitable for most Rheem Continuous Flow units

A

Hole size
Ø7mm

B

Flat Security Bracket – to be fixed to the masonry wall with
supplied anchors and shear-off nuts.

A

233
190

33
30

42
42
117

U Shaped Security Bracket –to be fastened to flat bracket using a
padlock (padlock not supplied)

B

86

168

PART 299868

Suitable for models: 875E24, 871E24,
875624, 871624, 875E26, 871E26, 876627,
874627

85

Rheem Recess Box
299842 (12-26L), 299831 (27L)

Features & Benefits
UÊ Galvanised Steel
UÊ Especially designed for standard double brick

construction, WA models suit solid brick construction
UÊ In-built anti-theft bracket
UÊ Easy access door

Security Bracket
Requires Padlock
(not Supplied)

TH

0
0

PART NO. FASCIA CAVITY

Height Width Depth Height Width Depth
B C D E F
A 425 25 347 160
435 50 1010 352 160
299842 (12-26L) 1088 425 59 1010 347 125
435 85 1015 353 125
299831 (27L) 1081 1018

299842/WA (12-26L) 1088

299831/WA (27L) 1091

Scan code for
details & installation

instructions

The installation position of the Rheem
Continuous Flow unit must comply with
AS 5601 or AS/NZS 5601.1. This should be
considered when choosing the installation
position of the Recess box.
86

Rheem Pipe Cover Kit 3-5 Indoor/
299841, 299848, 299830 Outdoor
PEOPLE
INSTALLATION

The Pipe Cover is to be installed after the Continuous Flow water
heater has been installed. The pipe cover is designed to be installed
underneath the water heater to cover the pipe work and valves, but
cannot cover the external GPO.

The kit contains:

1. Pipe cover housing

2. Pipe cover access panel

1
2

MODEL Scan code for
details & installation
299841 suitable for 12-20L/min
299848 suitable for 24L/min and 26L/min instructions
299830 suitable for 27L/min
87

Rheem Pronto® 13 - 24 Indoor/
834012 OOuuttddoooorr
PEOPLE
INSTALLATION

EN Features & BenefitsNT
UÊ Easy installation matching common

mechanical water heater fittings

UÊ 6 Star energy efficiency
UÊ 12 L/min continuous hot water

delivery @ 25oC rise

ERGSYTEAFRFICIE UÊ Electronic temperature control
UÊ Overheat protection
UÊ No electrical connection required
UÊ Available in natural and propane
UÊ Optional heat shield available - 299880
UÊ 10 year heat exchanger warranty1

285
268 120 120

840

R3.5

465

R8

45 45 70 70
388 222
COLD
HOT WATER HOT WATER
WATER INLET OUTLET
OUTLET GAS INLET
69 55
(FLUSH TO
BASE) GAS INLET

120 120 69

CL COLD
WATER
INLET

MODEL 834012

Min. Operating Flow rate (L/min) 3.0

Nom. Gas Consumption (MJ/hr) 99 Natural Scan code for
details & installation
Nom. Gas Consumption (MJ/hr) 96 Propane
instructions

Max Water Supply Pressure (kPa) 800

Min Water Supply Pressure (kPa) 120
Water Connections R1/2
Gas Connection Rp3/4
Approx. Weight (Empty) kg 21

88

Rheem Pronto® 1-3 Outdoor
834016
PEOPLE INSTALLATION

Features & Benefits

UÊ Easy installation matching common
mechanical water heater fittings

EN 5.9 NT UÊ 5.9 Star (NG) 5.8 Star (Propane)

ERGSYTEAFRFICIE UÊ 16 L/min continuous hot water
delivery @ 25oC rise

UÊ Electronic temperature control

UÊ Overheat protection

UÊ No electrical connection required

UÊ Available in natural and propane

UÊ Optional heat shield available - 299880

UÊ 10 year heat exchanger warranty1

285
268 120 120

875

R3.5

451

R8

50 50 84 84
443 222
COLD
HOT WATER HOT WATER
INLET OUTLET
WATER
OUTLET GAS INLET

(FLUSH TO

BASE)

69 48 120 120 69

GAS INLET CL COLD
WATER
INLET

MODEL 834016

Min. Operating Flow rate (L/min) 3.0

Nom. Gas Consumption (MJ/hr) 128 Natural Scan code for
details & installation
Nom. Gas Consumption (MJ/hr) 125 Propane
instructions
Max Water Supply Pressure (kPa) 800
89
Min Water Supply Pressure (kPa) 140
Water Connections R1/2
Gas Connection Rp3/4
Approx. Weight (Empty) kg 25

Conditions apply:
1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty
2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.
3 60ºC and higher temperature models and some applications require a

tempering valve in accordance with AS 3500.4.

Solar

Scan code for
details & installation

instructions

91

92

Rheem Loline 160L 1-4 Outdoor
511161
PEOPLE INSTALLATION

Features & Benefits

UÊ Split system design – vitreous enamel
lined cylinder installed at ground level

UÊ Limited frost protection4

UÊ 24 L/min in-series gas booster site
integrated or Rheem 27L/min in-series
gas booster installed remotely

UÊ Suitable with CSA2612 collector (VIC
& SA) or 2 LCS collectors (VIC only)

UÊ Eligible for STCs5

UÊ 5 year cylinder warranty1

514 695
480 23°

65° 47°110°

1615 SOLAR
987 PREHEAT
OUTLET

395

SOLAR HOT
(FROM
COLLECTOR)
INLET

937

529 COLD WATER
61
105 INLET

SOLAR COLD
(TO COLLECTOR) OUTLET

MODEL 511161

Storage Capacity (L) 165

Solar Collectors (VIC or SA) 1 CSA2612

Solar Collectors (VIC only) 2 LCS Scan code for
details & installation
Booster Type Gas
instructions
Weight Empty (kg)- Tank without booster 52
93
Weight Empty (kg)- Tank with booster 73

Tank Water Connections RP 3/4

Gas Booster Water Connections R3/4

Gas Connection R3/4

Rheem Loline 270L 2-5 Indoor/
511271 Outdoor
PEOPLE
INSTALLATION

Features & Benefits

UÊ Split system design – vitreous enamel
lined cylinder installed at ground level

UÊ Limited frost protection4

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ Gas booster tank mounting kit
available

UÊ 2 or 3 NPT200 or 2 LCS collectors

UÊ Eligible for STCs5

UÊ 5 year cylinder warranty1

640

32o 680
88o
32o
HOT WATER
OUTLET ELECTRICAL
CABLE ENTRY
TPR
VALVE SOLAR COLD

1395 588 OUTLET
SOLAR HOT INLET 1112
(FROM
(FROM COLLECTOR) COLLECTOR)

412 73

COLD WATER 73
INLET

MODEL 511271 Scan code for
details & installation
Storage Capacity (L) 270
Solar Collectors 2 or 3 NPT200, instructions

Booster Type 2 LCS
Element size (kW) Electric or Gas
Weight Empty (kg) - Tank
Water Connections 3.6
94 71
RP 3/4

Rheem Loline 325L 2-6 Indoor/
511325 Outdoor
PEOPLE
INSTALLATION

Features & Benefits

UÊ Split system design – vitreous enamel
lined cylinder installed at ground level

UÊ Limited frost protection4

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ Gas booster tank mounting kit
available

UÊ 2 or 3 NPT200 or 2 LCS collectors

UÊ Eligible for STCs5

UÊ 5 year cylinder warranty1

640

32o 680
88o
32o
HOT WATER
OUTLET ELECTRICAL
CABLE ENTRY
T&PR
VALVE SOLAR COLD

1640 710 OUTLET

SOLAR HOT 1357 (FROM
INLET 481 COLLECTOR)
(FROM
73
COLLECTOR)

COLD WATER
INLET

73

MODEL 511325 Scan code for
details & installation
Storage Capacity (L) 325
Solar Collectors 2 or 3 NPT200, instructions

Booster Type 2 LCS 95
Element size (kW) Electric or Gas
Weight Empty (kg) - Tank
Water Connections 3.6
87
RP 3/4

Rheem Loline 410L 3-7 Indoor/
511410 Outdoor
PEOPLE
INSTALLATION

Features & Benefits

UÊ Split System design – vitreous enamel
lined cylinder installed at ground level

UÊ Limited frost protection4

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ 2, 3 or 4 NPT200 or 2 or 3 LCS
collectors

UÊ Eligible for STCs5

UÊ 5 year cylinder warranty1

690

30o 730
82o
30o
HOT WATER
OUTLET ELECTRICAL
CABLE ENTRY
T&PR
VALVE SOLAR COLD

1840 795 OUTLET

SOLAR HOT INLET 1519 (FROM
COLLECTOR)
(FROM COLLECTOR)
81
COLD WATER 532
INLET 81

MODEL 511410

Storage Capacity (L) 410 Scan code for
Solar Collectors 2, 3 or 4 NPT200, details & installation

Booster Type 2 or 3 LCS instructions
Element size (kW) Electric or Gas
Weight Empty (kg) - Tank
Water Connections 3.6
96 111
RP 3/4

Rheem Premier ® Loline 160L 2-5 Outdoor
590160
PEOPLE INSTALLATION

Features & Benefits

UÊ Complete Frost Protection – Unique
Drain-Back™ heat exchange
technology

UÊ Complies with regulations in all states

UÊ Booster – 6-star continuous flow gas

UÊ Compact spilt system design

UÊ 1 T200, 2 NPT200 or 2 LCS
collectors

UÊ Eligible for STCs5

UÊ 5 year cylinder warranty1

423 212
51

503
211

SOLAR SOLAR
PREHEAT CONNECTIONS
OUTLET
TPR
VALVE

1818 1613
1615 1858

1213

COLD 402
WATER
INLET

MODEL 590160

Storage Capacity (L) 160 Scan code for
Solar Collectors 1 T200, 2 LCS details & installation

Booster Type or 2 NPT200 instructions
Weight Empty - (kg) Tank Gas
Tank Water Connections 93 97
Gas Booster Water Connections RP 3/4
Gas Connections R 3/4
R 3/4

Rheem Premier® Loline 160L 2-5 Outdoor
596160
PEOPLE INSTALLATION

Features & Benefits

UÊ Complete Frost Protection – Unique
Drain-Back™ heat exchange
technology

UÊ Complies with regulations in all states

UÊ Booster – 6-star 20 L/min continuous
flow gas (factory fitted)

UÊ Compact spilt system design

UÊ 1 T200, 2 NPT200 or 2 LCS
collectors

UÊ Eligible for STCs5

UÊ 5 year cylinder warranty1

423 212
51

690
503
211

SOLAR SOLAR
PREHEAT CONNECTIONS
OUTLET
TPR
HOT VALVE
WATER 1818
OUTLET 1206
402 805 408
COLD
WATER 1613
INLET 1858

MODEL 596160

Storage Capacity (L) 160

Solar Collectors 1 T200, 2 LCS Scan code for
details & installation
or 2 NPT200
instructions

Booster Type Gas

Weight Empty (kg) - Tank 112

Water Connections RP 3/4
Gas Booster Water Connections R 3/4
Gas Connections R 3/4

98

Rheem Premier® Loline 270L 2-5 Outdoor
596270
PEOPLE INSTALLATION

Features & Benefits
UÊ Complete Frost Protection – Unique

Drain-Back™ heat exchange
technology

UÊ Complies with regulations in all states
UÊ Booster – 27 L/min 6-star continuous

flow gas (site integrated)

UÊ Full mains pressure for multiple outlets
UÊ Integrated tempering valve
UÊ 2 or 3 SPA2000 or T200 collectors
UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

648
182

215 324

890
48o

351

FLUE
TERMINAL

1701 1654
1787 1455

510
772

265

MODEL 596270

Storage Capacity (L) 270

Solar Collectors 2 or 3 SPA2000 Scan code for
Booster Type details & installation
2 or 3 T200 instructions

Gas

Weight Empty - (kg) Tank without booster 141

Weight Empty - (kg) Tank with booster 165
Water Connections RP 3/4
Gas Connections R 3/4

99

Rheem Premier® Loline 270L 2-5 Indoor/
591270 Outdoor
PEOPLE
INSTALLATION

Features & Benefits
UÊ Complete Frost Protection – Unique

Drain-Back™ heat exchange
technology

UÊ Complies with regulations in all states
UÊ Booster – electric element
UÊ Full Mains Pressure for multiple outlets
UÊ 2 or 3 SPA2000 or T200 collectors
UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

648

47o 324 344385
73o 682

HOT WATER ELECTRICAL
OUTLET CABLE ENTRY

TPR 980
VALVE

1775 1078

1701

COLD WATER
INLET

377

MODEL 591270

Storage Capacity (L) 270 Scan code for
Solar Collectors 2 or 3 SPA2000 details & installation

Booster Type 2 or 3 T200 instructions
Element size (kW) Electric
Weight Empty (kg) - Tank 3.6
Weight Empty - (kg) 146

Solar Collector (each) 48

Water Connections RP 3/4
100

Rheem 52L Series 1-2 Outdoor
52L180
PEOPLE INSTALLATION

YLINDE R Features & Benefits
W
7C UÊ Suitable for temperate or tropical
TY location
YEAR
ARRAN UÊ Stainless steel cylinder

UÊ The 52L Series system directly heats
the water as it passes through the
collectors

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ Eligible for STCs5

UÊ 7 year cylinder warranty1 with NPT200
collector

UÊ 10 year cylinder warranty1 with
L, CSA2007 collector*

HOT WATER 563 1495
OUTLET

TPR
VALVE

ELECTRICAL 79
CONNECTION 10212138

COLD 1937
WATER
INLET

2490

* Available through Rheem Solar Specialists only

MODEL 52L180

Storage Capacity (L) 180 Scan code for
Solar Collectors 1 NPT200, L, details & installation

Booster Type CSA2007 instructions
Weight Empty (kg) - Tank Electric or Gas
Weight Empty - (kg)
48
Solar Collector (each)
33
Water Connections
Gas Connections DN15 Compression
DN15 Compression

101

Rheem 52L Series 2-5 Outdoor
52L300
PEOPLE INSTALLATION

YLINDE R Features & Benefits
W
C7 UÊ Suitable for temperate or tropical
TY location
YEAR
ARRAN UÊ Stainless steel cylinder

UÊ The 52L Series system directly heats
the water as it passes through the
collectors

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ Available in four COLORBOND® Steel
colours

UÊ Eligible for STCs5

UÊ 7 year cylinder warranty1

UÊ 10 year cylinder warranty1 with
L, CSA2007 collector*

563 2180

HOT WATER 79
OUTLET 20924198

TPR
VALVE

ELECTRICAL
CONNECTION

COLD
WATER
INLET

2490 1937

* Available through Rheem Solar Specialists only

MODEL 52L300 Scan code for
details & installation
Storage Capacity (L) 300
Solar Collectors 2 NPT200, instructions
L, CSA2007
Booster Type Electric or Gas
Weight Empty (kg) - Tank
Water Connections 72
102 DN15 Compression

Rheem Hiline 52S 1-2 Outdoor
52S160
PEOPLE INSTALLATION

Features & Benefits
UÊ Energy efficient
UÊ Booster – choice of electric element

or 6-Star continuous flow gas

UÊ Vitreous enamel lined cylinder
UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

HOT WATER 540 1070
OUTLET

TPR
VALVE

ELECTRICAL 79
CONNECTION 1022 1138

COLD
WATER
INLET

2490 1937

MODEL 52S160 Scan code for
details & installation
Storage Capacity (L) 160
Solar Collectors 1 NPT200 instructions
Booster Type Electric or Gas
Weight Empty (kg) - Tank 103
Hot Water Connection 70
Cold Water Connection RP 3/4
G 1/2 B

Rheem Hiline 52S 23 - 5 Outdoor
52S300
PEOPLE INSTALLATION

Features & Benefits
UÊ Energy efficient
UÊ Booster – choice of electric element

or 6-Star continuous flow gas

UÊ Vitreous enamel lined cylinder
UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

HOT WATER 540 1865
OUTLET

TPR 79
VALVE 1022 20924198

ELECTRICAL
CONNECTION

COLD
WATER
INLET

2490 1937

MODEL 52S300 Scan code for
details & installation
Storage Capacity (L) 300
Solar Collectors 2 NPT200 instructions
Booster Type Electric or gas
Weight Empty (kg) - Tank
Hot Water Connection 100
Cold Water Connection RP 3/4
104 G 1/2 B

Rheem Premier® Hiline 52H 1-2 Outdoor
52H180
PEOPLE INSTALLATION

RYLINDEFeatures & Benefits
W
C7 UÊ Complete frost protection
TY
YEAR UÊ Space saving design – a complete
ARRAN roof mounted installation

UÊ Stainless steel cylinder

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ Eligible for STCs5

UÊ 7 year cylinder warranty1 with
SPA2000, NPT200

UÊ 10 year cylinder warranty1 with
L, CSA2007 collector*

HOT WATER 563 1495
OUTLET

TPR
VALVE

ELECTRICAL 79
CONNECTION 10212138

COLD 1937
WATER
INLET

2490

* Models with NPT200, L, CSA2007 collectors
available through Rheem Solar Specialists only

MODEL 52H180

Storage Capacity (L) 180 Scan code for
Solar Collectors 1 SPA2000, details & installation
NPT200, L
Booster Type instructions
Weight Empty (kg) - Tank
Hot Water Connection Electric or Gas
Cold Water Connection
52

DN15 Compression

DN15 Compression

105

Rheem Premier® Hiline 52H 2-5 Outdoor
52H300
PEOPLE INSTALLATION

RYLINDEFeatures & Benefits
W
C7 UÊ Complete frost protection
TY
YEAR UÊ Space saving design – a complete
ARRAN roof mounted installation

UÊ Stainless steel cylinder

UÊ Booster – choice of electric element
or 6-Star continuous flow gas

UÊ Eligible for STCs5

UÊ 7 year cylinder warranty1 with
SPA2000, NPT200

UÊ 10 year cylinder warranty1 with
L, CSA2007 collector*

563 2180

HOT WATER 79
OUTLET 20924198

TPR
VALVE

ELECTRICAL
CONNECTION

COLD
WATER
INLET

2490 1937

* Models with NPT200, L, CSA2007 collectors
available through Rheem Solar Specialists only

MODEL 52H300 Scan code for
details & installation
Storage Capacity (L) 300
Solar Collectors 1 SPA2000, instructions
NPT200, L
Booster Type Electric or Gas
Weight Empty - (kg) Tank
Hot Water Connection 79
Cold Water Connection R 3/4
106 RP 1/2

Rheem Premier® Hiline 300L 2-5 Outdoor
52C300
PEOPLE INSTALLATION

Features & Benefits
UÊ Complete frost protection
UÊ Energy efficient
UÊ Booster – choice of electric element

or 6-Star continuous flow gas

UÊ Suitable for a range of water supplies
UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

HOT WATER 2290

OUTLET 508

T.P.R

VALVE

ELECTRICAL 77
CONNECTION

COLD 2475 1937 1022 2118 2425
WATER
INLET

MODEL 52C300 Scan code for
details & installation
Storage Capacity (L) 300
Solar Collectors 2 NPT200 instructions
Booster Type Electric or Gas
Weight Empty - (kg) Tank 107
Hot Water Connection 109
Cold Water Connection DN15 Compression

R 3/4

Rheem Collectors Outdoor
NPT200, LCS, CSA2007, SPA2000,
T200, CSA2612, L INSTALLATION

A B

PIPE WORK TO SOLAR COLLECTORS

2.0m2 Collector A B
1 Collector 1240 1875
2 Collector 2360 1875
3 Collector 3480 1875
3 Collector 3480 1875
2.6m2 Collector
1 Collector 1340 2165

COLLECTOR DATA

Collector Dimension Weight Kg System
(empty)
NPT200 direct/indirect
LCS 1943 x 1027 x 82 36 direct/indirect
CSA2007 1943 x 1027 x 82 31 direct/indirect
SPA2000 1996 x 1043 x 82 36
T200 1996 x 1043 x 82 45 indirect
CSA2612 1943 x 1027 x 82 48 indirect
L 2285 x 1130 x 82 47 direct
1943 x 1027 x 82 29 direct/indirect

108

Conditions apply:
1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty
2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.
3 60ºC and higher temperature models and some applications require a

tempering valve in accordance with AS 3500.4.
4 Frost protection to 400m altitude above sea level
5 Eligibility criteria apply.

109

110

Heat Pump

111

Scan code for
details & installation

instructions

112

HDi-310 3-6 Outdoor
551310
PEOPLE INSTALLATION

Features & Benefits
UÊ Top Down heating
UÊ No Solar collectors
UÊ Energy efficient
UÊ Back-up element – Provides hot water

regardless of the weather

UÊ Fits on a compact footprint
UÊ LED display to indicate operating

status

UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

WALL CONDENSATE
DRAIN
100

300 300 679
MIN MIN

30O
50O

643 VENTILATION
670 CLEARANCE

TPR
VALVE

AIR AIR
INLET OUTLET

HOT
OUTLET

1870

1075 820

COLD
OUTLET

108

MODEL 551310 Scan code for
details & installation
Storage Capacity (L) 310
Element Rating (kW) 3.6 instructions
Relief Valve Setting (kPa) 1000
Expansion Control Valve (kPa) 850 113
Max Water Supply Pressure:
680
with ECV (kPa) 800
without ECV (kPa) RP 3/4
Water Connections 135
Approx. Weight (Empty) kg

MPi-325 Series II 2-5 Outdoor
551325
PEOPLE INSTALLATION

Features & Benefits

UÊ Multi-pass heating – Heats the water
by passing the water through the heat
exchanger multiple times

UÊ No Solar collectors

UÊ Back up electric element

UÊ One man installation – can be fully
installed by plumbing regular trades

UÊ LED display to indicate operating
status

UÊ Eligible for STCs5
UÊ 5 year cylinder warranty1

WALL

100 AIR INLET

AIR 638
OUTLET

32O 300 MIN 574

TPR AIR VENTILATION
VALVE INLET CLEARANCE
CONDENSATE DRAIN
619 275
894

HOT AIR INLET
OUTLET
VENTILATION
CLEARANCE

300 min

1631 AIR 1018
1317 OUTLET 872

COLD 544
INLET
162
114
ELECTRICAL
MODEL CONNECTION

Storage Capacity (L) 551325 Scan code for
Element Rating (kW) details & installation
Relief Valve Setting (kPa) 325
Expansion Control Valve (kPa) 3.6 instructions
Max Water Supply Pressure: 1000
850
with ECV (kPa)
without ECV (kPa) 680
Water Connections 800
Approx. Weight (Empty) kg RP 3/4
114 130


Click to View FlipBook Version