Technical Training Syringe Pump (Mindray BeneFusion eSP), JKN NS, 7 & 8 June 2022

02-BeneFusion nSP&eSP Syringe Pump Training_V3.0_EN (1) - JKN NS

Keywords: Technical training

7 & 8 June 2022

BeneFusion nSP/eSP Syringe Pump Training

BeneFusion nSP BeneFusion eSP

Applicable to nSP ex/nSP Neo Applicable to eSP ex/eSP Neo

2 © 2016 Mindray Confidential

Content

Introduction

 Appearance
 Technical Specification
 Operation
 Feature

Installation

 Installation Process
 Standard Pump
 Mass Installation
 Customer Training

3 © 2016 Mindray Confidential

Objective:

 Be familiar with the nSP/eSP and the specification
 Ability to perform the calibration and Installation

4 © 2016 Mindray Confidential

1 Introduction

5 © 2016 Mindray Confidential ✓ Appearance
 Technical specification
 Operation
 Feature

Introduction

BeneFusion nSP/eSP Syringe Pump

 Designed to accurately control and monitor the flow of solutions to the patient.
 Rated for adults, children and newborns use
 Apply to ICU, CCU, PICU, NICU, OR, ER, general ward

WARNING

This product must not be operated by anyone who has not received professional training.

6 © 2016 Mindray Confidential

Appearance——Front View Viewing Window
Stainless steel axle
nSP Electric push & pull box

Alarm Light On-Off
Red and Yellow. Observable STOP

7 inch capacitive
touchscreen

Weight:≤1.7Kg. Size:≤257x 150 x73(mm)

7 © 2016 Mindray Confidential

Appearance——Front View Infusion status
indicator
eSP
Stainless steel axle
Alarm Light
Red and Yellow. Observable Electric push & pull box

3.5 inch capacitive
touchscreen

STOP On-Off

Weight:≤1.6Kg. Size:≤257x 150 x73(mm)

8 © 2016 Mindray Confidential

Appearance——Rear View Speaker

1、DC supply USB Port
2、DOCK communication
3、Nurse Call FAT32 format USB
4、PCA Port 1、upgrade the system
software
Multifunction Interface 2、Export and import brand
library and configuration
9 © 2016 Mindray Confidential 3、Import drug library
4、Export history record

AC Port

Appearance——Bottom View

Placement for stacking pump Placement for pole
Max 3 pumps clamp

10 © 2016 Mindray Confidential

Appearance——Door Open Flange detection sensor

Magnet

Extension tube Syringe Holder
hook

Syringe installation guidance Syringe fixing clamp
label

11 © 2016 Mindray Confidential

Appearance——Accessary The step is designed for the
waterproof
Power
Cord

12 © 2016 Mindray Confidential

Appearance——Accessary

Standard stack Fast clamping clamp (high
structure configuration)

Standard pole Adjust the handle direction to match the
clamp Vertical and horizontal pole

13 © 2016 Mindray Confidential Manual fasten the screw to fix
the device and clamp

SN rule

N series XXX X X X XXXXXX(T)

TCN

Model code Product Serial SG1-0800001T
“-” number
nSP-SG1 Initiation
nSP ex-SG2 Component 000001
nSP Neo-SG3 “A”
Month
nVP-SG4 Year 1-9、
nVP ex-SG5 0-9 A(Oct.)、B、
nVP Neo-SG6 C

nDS-SG7
nDS ex-SG8

nCS-SG9

14 © 2016 Mindray Confidential

SN rule

E series XXX X X X XXXXXX(T)

TCN

Model code Product Month Serial
“-” 1-9、 number
eSP-SH1 A、B、C Initiation
eSP ex-SH2 Component 000001
eSP Neo-SH3 “A”
SG1-0800001T
eVP-SH4 Year
eVP ex-SH5 0-9
eVP Neo-SH6

eDS-SH7
eDS ex-SH8

eCS-SH9

15 © 2016 Mindray Confidential

1 Introduction

16 © 2016 Mindray Confidential  Appearance
✓ Technical specification
 Operation
 Feature

Introduction——Technical Specification

No. Items Specification

1 Syringe ⚫ 1ml、2ml、3ml、5ml、10ml、20ml、30ml、50/60ml

2 Accuracy error ⚫ Accuracy error≤±1.8%,bolus accuracy error ≤±2%或0,05ml

3 Rate ⚫ 1ml:0.01-50ml/h
⚫ 2/3ml:0.01-150ml/h
⚫ 5/6ml:0.01-300ml/h
⚫ 10/12ml:0.1-800ml/h
⚫ 20ml:0.1-1200ml/h
⚫ 30/35ml:0.1-1500ml/h
⚫ 50/60ml:0.1-2300ml/h

4 Infusion Mode ⚫ 9 modes available
⚫ Rate/ Dose/ Time/ Dose Time/ Sequential/ Intermittent/ Loading Dose/ Ramp/

Micro-infusion
⚫ No Loading Dose in Ex Ver. No Ramp Mode in Neo
⚫ TCI/TIVA/PCA Optional。

5 Pressure detection ⚫ 15 level are adjustable
⚫ 50/150/225/300/375/450/525/600/675/750/825/900/975/1050/1125 mmHg
⚫ Unit ,mmHg / Kpa / bar / psi

Note: 50mmHg and 15ul are not accessible in General Option, but in User maintenance

17 © 2016 Mindray Confidential

Introduction——technical Specification

No. Items Specification

7 KVO Rate ⚫ 0.1 ~5.0ml/h,Default:0.5ml/h
8 History Record
9 Drug Library ⚫ Max 3500

10 Audio Alarm ⚫ 5000 drugs
12 Brightness ⚫ 30 Colors
13 Battery run time ⚫ 50 Categories
14 Lock Time
⚫ 3 Sound
⚫ 8 level adjustable

⚫ 8 level adjustable
⚫ Brightness on Battery adjustable

⚫ Normal battery:Run time 5H,charge time5H. 7.2V,2600mAH
⚫ Intelligent battery:Run time 11H,charge time 6H. 10.8V,2900mAH

⚫ Lock Time For No Infusion:OFF/1/2/3/4/5min
⚫ Lock Time In Infusion :OFF/15s/30s/1/2/3/4/5min

18 © 2016 Mindray Confidential

1 Introduction

19 © 2016 Mindray Confidential  Appearance
 Technical Specification
✓ Operation
 Feature

Operation——Turn On

1. Press [On-Off] button。
2. The loading guidance will be displayed on the screen
3. The push & pull box will move out automatically ,and the clamps will be open

20 © 2016 Mindray Confidential

Operation——Loading the syringe

3. Open the door Press this place
4. Pull down the syringe clamp

Press this place

21 © 2016 Mindray Confidential

Operation——Loading the syringe

5. Place the syringe into the syringe slot, ensure that the barrel flange is in the space between the pump
and the flange holder

6. Lift the syringe clamp until it locks the syringe
7. The push box automatically slides left until it reaches the plunger end, the push box automatically

squeeze the plunger flange and clamps hold the plunger.

Keep the scale mark Fool proof
outside If the syringe is not installed correctly,

it will not be detected

pull up the syringe fixing The sensor will detect the status(to touch or not to touch)
clamp

22 © 2016 Mindray Confidential

Operation——Drug & Brand Selection

nSP

If turn off the brand selection,
no this interface;

9:16

Common Other Drug A

10%KCl 10%NaCl 25%MgSO Bolus The pump can be configured
Belladonna with a drug library or a drug info
library
Search
50%Glucose Aminophylline Exit

1/9

23 © 2016 Mindray Confidential

Operation——Drug & Brand Selection Search

eSP

If turn off the brand selection, The pump can be configured
no this interface; with a drug library or a drug info
library
24 © 2016 Mindray Confidential

Operation——Parameter Setting

VTBI Bolus

Infusion Mode Rate Time Start
Syringe type

25 © 2016 Mindray Confidential

Operation——Parameter Setting

Rate VTBI
Time

Infusion Mode Syringe type

Bolus Start

26 © 2016 Mindray Confidential

Operation——Lock&Unlock

Lock Unlock

27 © 2016 Mindray Confidential

Operation——Running

Running progress bar You can modify rate, dose rate, drug name, pressure without stopping
the infusion.

VTBI: The remaining infusion
time is the expected time

No VTBI: the remaining
infusion time is empty time

28 © 2016 Mindray Confidential

Operation——Running

VTBI No VTBI
You can modify rate, dose rate, drug name, pressure without stopping
the infusion.

29 © 2016 Mindray Confidential

Operation——Bolus

Bolus: Manual or Automatic

1、Automatic Bolus Infusion

⚫ Select【Bolus】, the Bolus setting interface will be displayed in the screen.
⚫ Select bolus volume and select 【Bolus】to start a bolus infusion

2、Manual Bolus Infusion

⚫ Press and hold【Bolus】to deliver a bolus infusion
⚫ Bolus will be stopped when you release the【Bolus】or the bolus volume limit (0~20ml) is reached

30 © 2016 Mindray Confidential

Operation——Bolus

Remaining time

Automatic Bolus Infusion

⚫ Select【Bolus】, the Bolus setting interface will be displayed in the screen.
⚫ Select bolus volume and select 【Bolus】to start a bolus infusion

31 © 2016 Mindray Confidential

Operation——Bolus

Manual Bolus Infusion

⚫ Press and hold【Bolus】to deliver a bolus infusion
⚫ Bolus will be stopped when you release the【Bolus】or the bolus volume limit (0~20ml) is reached

32 © 2016 Mindray Confidential

Operation——Turn Off

12. Remove the syringe and turn off 。
➢ The pump cannot be turned off if the syringe is not removed
➢ The plunger holder automatically slides left
Pull down the syringe clamp ,the push box
automatically slider right and release the syringe

33 © 2016 Mindray Confidential

Operation——Alarm

Alarm Priority Alarm Lamp Alarm Lamp Alarm Sound Alarm Message Alarm priority Duty cycle
Color Flashing Frequency Interval indicator

High priority Red 2.0±0.6Hz 5s(±2s) White text or symbol *** 20% to 80%
alarm inside a red box
Not flashing
Low priority Yellow 20s(±2s) Black text or Symbol * 100%
alarm inside a yellow box

High Priority Alarm
Air In Line, Accumulated Air, Empty, Drop Error, Upstream Occlusion, Downstream Occlusion, Infusion Set Disengaged,
No Infusion Tube, Infusion Set Error, No Drop Sensor, Battery Depleted, VTBI Complete, KVO finish, Relay Invalid,
System Error

Low Priority Alarm
KVO Running, Battery in Use, Battery Error, CMS/eGW Disconnected, Standby Time Expired, Dock Connection
interrupted, System Time Error, Relay Invalid soon, Time Near End, Reminder, Low battery

34 © 2016 Mindray Confidential

Operation——Alarm

√ ***Downstrem Occlusion 9:16

10% NaCl Check the infusion set or adjust the limit

Rate Mode Rate 55.0 Peak Pressure:383>=Pressure Threshold:375 Alarm Reset
AudioPause
Regular-Bbraun Pause Pressure Setup

ml/h

Audio Pause Alarm Reset

Touch to silence the alarm sound Touch to acknowledge and reset the alarm

 Alarms will be silenced for 2 min,except for Battery depleted  √ appears in the front of the alarm message
 Alarm sound is silenced
 will be displayed in the behind of alarm message
 is displayed in the behind of alarm message
 If a new alarm is triggered during the audio pause, No alarm sound

35 © 2016 Mindray Confidential

Operation——Alarm

36 © 2016 Mindray Confidential

Operation——Relay & Volume

Relay mode is available in n/e series pump, nDS or eDS is required

9:16

10% NaCl VTBI Vloume

Audio Pause Relay Lock 30Standby .6P4urge 19Volume.36 Menu

5.0 ml ml Bolus

Rate Mode Rate Time Pressure 450
mmHg
Regular-Bbraun Pause 06:07:57 0 Start

ml/h h:m:s

37 © 2016 Mindray Confidential

Operation——Menu

Menu

38 © 2016 Mindray Confidential

Operation——General Option

General Option

39 © 2016 Mindray Confidential

Operation——System Option

System Option

40 © 2016 Mindray Confidential

Operation——User Maintenance

Log in

Password is required, 8868@m

41 © 2016 Mindray Confidential

1 Introduction

42 © 2016 Mindray Confidential  Appearance
 Technical Specification
 Operation
✓ Feature

Feature——Easy to use

UI Friendly

7/3.5 inch Capacitive Touchscreen

Syringe loading Easy

Electric plunder holder system

Alarm Clear

Navigating Alarm Solution

Infusion Smooth

Circular & Customized Relay

43 © 2016 Mindray Confidential

Feature——Safety & Efficiently

Drug Name with different Color, easy to distinguish
Infusion View, easy to observe the treatment
DERS drug library, safety to use the drug
Common drug setting, easy to start the infusion

44 © 2016 Mindray Confidential

Feature——New Technology

⚫ Response Fast
2 seconds to turn on and 3 seconds to start infusion

⚫ Infusion accurate
Accuracy error ±1.8%

⚫ Intelligent occlusion management system
• Occlusion alarm triggered, the pump can automatically restart when it detects the occlusion has released.
• If infusion restart fails 5 times, anti-bolus will help to release the pressure in the tube

⚫ extension Tube detection

45 © 2016 Mindray Confidential

2 Installation

46 © 2016 Mindray Confidential ✓ Installation Process
 Standard Pump
 Mass Installation
 Customer Training

Installation——Installation Process Tool Required

1、USB

2、Maintenance Kit

1. Calibrate 1 pump and 3、knife

configurate the infusion Prepare: Prepare Standard Pump
parameter Collect the IV eSP or nSP
2. Export the configuration set information

information Mass Installation

OPEN BOX System Check Upgrade Brand Configurate Fixing
Information Parameter

Select 1 unit for accuracy confirmation Accuracy
Confirmation
47 © 2016 Mindray Confidential

2 Installation

48 © 2016 Mindray Confidential  Installation Process
✓ Standard Pump
 Mass Installation
 Customer Training

Installation——Prepare Standard Pump

Brand information

Standard Infusion Parameter
pump

Drug Library

eSP and nSP use same standard pump

49 © 2016 Mindray Confidential

Installation——Brand Management

Brand management Take nSP as an example

Menu——User Maintenance——Brand Management

Add or modify the infusion IV set Brand information in system according to the customer requirement

50 © 2016 Mindray Confidential


Click to View FlipBook Version