4 mm gap left between end of weatherboards and corner flashing Ulltraclad© UA4529 Male Corner Flashing fixed to wall framing with 30x2.5 mm clouts @ 600 mm ctrs

Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by , 2016-09-03 21:03:03

Ullrich Details PDF - UlltraClad

4 mm gap left between end of weatherboards and corner flashing Ulltraclad© UA4529 Male Corner Flashing fixed to wall framing with 30x2.5 mm clouts @ 600 mm ctrs

600 600 600 600

Horizontal Cavity batten 1 Batten 1
battens at fixing
between verticals 600 mm C.03 points C.04
at soffit centres
1
2
C.07
C.04
1
1 Window 800 mm
C.08 Maximum nog 800 800
C.12 Meter
Box 1 spacing
1
C.09
C.13
1
1
C.02
C.14
1
1
C.06
C.01
Two cavity
1 battens fixed
side by side
C.05 at
window open
Stud can be 45 or 35 mm
wide

Ullrich Aluminium Co. Ltd. C.00
Ulltraclad© Aluminium Cladding
September 2012 Wall Batten Elevation

Note: Leave a 10 mm gap between 4 mm gap left between end of
battens weatherboards and corner flashing

Wall frame Ulltraclad© UA4530 Female Corner
Interior lining Flashing
Ulltraclad© UA4529 Male Corner
Flashing fixed to wall framing with
30x2.5 mm clouts @ 600 mm ctrs

Ulltraclad© locater fixed to each
stud with Ulltraclad© screws

Note: Leave a 10 mm gap between
battens

45x18 mm cavity battens

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

Ulltraclad© Weatherboards

Building underlay continuous
around corner

Ullrich Aluminium Co. Ltd. 1 : 2 C.01
Ulltraclad© Aluminium Cladding
September 2012 External Corner On Cavity

Ulltraclad© weatherboard. Leave Note: Double studs
4mm expansion gap at end of required at internal
board corners

Building underlay continuous Interior lining
around corner

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

45x18 mm cavity battens

Ulltraclad© locater fixed to each
stud with Ulltraclad© screws

Ulltraclad© UA4529 Male Corner
Flashing

Ulltraclad© UA4530 Female Corner
Flashing fixed to wall framing with
30x2.5 mm clouts @ 600 mm ctrs

Note: Leave a 10 mm gap between
battens

Ullrich Aluminium Co. Ltd. 1 : 2 C.02
Ulltraclad© Aluminium Cladding
September 2012 Internal Corner On Cavity

4 mm gap left between end of Ulltraclad© UA6323 Jointer Top
weatherboards and vertical wall Ulltraclad© UA6324 Jointer Bottom
jointer fixed to wall frame with 30x2.5 mm
45x18 mm cavity battens clouts @ 600 mm ctrs
Underlay strips to isolate aluminium
Ulltraclad© Weatherboards from treated battens (Alternatively
use 'CAVIBAT' system)
Building underlay
Leave a 10mm gap between battens

Double studs behind vertical jointer
Interior lining

Ullrich Aluminium Co. Ltd. 1 : 2 C.03
Ulltraclad© Aluminium Cladding
September 2012 Vertical Wall Jointer

Sealant over PEF backing rod

Ulltraclad© UA4535 Locater Clip 10
fixed to each stud with Ulltraclad©
screws

45x18 mm cavity battens

Building underlay

Ulltraclad© weatherboards

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

Ullrich Aluminium Co. Ltd. 1 : 2 C.04
Ulltraclad© Aluminium Cladding
September 2012 Soffit Detail On Cavity

Soffit lining

Ulltraclad© UA5833 Clip Top

Ulltraclad© UA5831 Soffit Clip
Base fixed to wall framing with
50x2.5 mm clouts

45x18 mm cavity battens

Building underlay

Ulltraclad© UA4535 Locater Clip
fixed to each stud with Ulltraclad©
screws

Ulltraclad© weatherboards

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

Ullrich Aluminium Co. Ltd. 1 : 2 C.04
Ulltraclad© Aluminium Cladding
September 2012 Soffit Detail On Cavity

Ulltraclad© weatherboards 50 overhang Interior lining
Ulltraclad© UA4535 Locater Clip Bottom plate over
fixed to each stud with Ulltraclad© 175 DPC
screws to unpaved ground to clause Concrete slab or
Underlay strips to isolate aluminium blockwork
from treated battens (Alternatively 9.1.3 of E2/AS1
use 'CAVIBAT' system) (100mm to permanent paving) 1 : 2 C.05
45x18 mm cavity battens
Building underlay Wall Starter On Cavity
Ulltraclad© cavity vent strip
Ulltraclad© UA4862 Starter Strip
fixed to bottom plate with 50 x 2.5
mm clouts @ 600 mm ctrs

Finished ground level

Ullrich Aluminium Co. Ltd.
Ulltraclad© Aluminium Cladding
September 2012

Ulltraclad© UA4535 Locater Clip Interior lining
fixed to each stud with Ulltraclad© Bottom plate
screws
Timber floor structure
Ulltraclad© weatherboards in accordance with
NZS 3604:2011
Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)
45x18 mm cavity battens
Building underlay
Ulltraclad© cavity vent strip
Ulltraclad© UA4862 Starter Strip
fixed to bottom plate with 50 x 2.5
mm clouts @ 600 mm ctrs

50 overhang

Ullrich Aluminium Co. Ltd. 1 : 2 C.06
Ulltraclad© Aluminium Cladding
September 2012 Wall Starter Timber Floor On Cavity

Underlay strips to isolate aluminium 15 Interior lining
from treated battens (Alternatively 35 min
use 'CAVIBAT' system) Airseal to perimeter of trim
flashing upstand cavity with expandable foam
Ulltraclad© UA4535 Locater Clip or sealant over PEF rod as
fixed to each stud with Ulltraclad© 10 mm cover per section 9.1.6 of E2/AS1
screws
10 mm gap nominal
Ulltraclad© weatherboards Window liner
H3.1 treated packers
45x18 mm cavity battens Flexible flashing tape at
corners
Building underlay continuous
behind head flashing and into
opening

Ulltraclad© cavity vent strip

Second layer of building underlay
over head flashing upstand

Ulltraclad© UA4533 Head Flashing.
5mm diameter drainage holes
drilled through base of flashing @
300 mm ctrs.

Sealant between head flashing and
window flange in Very High wind
zone and above
Window head flashing 15° slope
(Note: Not supplied with Ulltraclad©
system - contractor to supply as
additional flashing)

Window frame (Note: refer to
window manufacturer for method of
support and fixing)

5 mm gap between head flashings

Ullrich Aluminium Co. Ltd. 1 : 2 C.07
Ulltraclad© Aluminium Cladding
September 2012 Window head On Cavity

Ulltraclad© UA4532 Window
Flashing fixed to wall framing with
50 x 2.5 mm clouts @ 600 mm ctrs.

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

Double 45x18 mm cavity battens,
10mm gap between

Building underlay

continuous around opening min 10 mm cover

Ulltraclad© Weatherboards

Inseal 3109 - min 19 mm thick x 10
mm wide

Window frame (Note: refer to
window manufacturer for method of
support and fixing)

Window liner

H3.1 treated packers

Flexible flashing tape 100 mm
minimum up jamb

Airseal to perimeter of trim cavity
with expandable foam or sealant
over PEF rod as per section 9.1.6
of E2/AS1

Interior lining

10 mm gap nominal

Ullrich Aluminium Co. Ltd. 1 : 2 C.08
Ulltraclad© Aluminium Cladding
September 2012 Window Jamb On Cavity

Flexible flashing tape along entire Airseal to perimeter of
sill, 100 mm up each jamb and 50 trim cavity with
mm onto face of building underlay expandable foam or
sealant over PEF rod
Window frame (Note: refer to as per section 9.1.6 of
window manufacturer for method of E2/AS1
support and fixing) Window liner

Add window support bar. Required Interior lining
for windows wider than 600mm
H3.1 treated packers
10 mm min cover

100 mm long soaker located at 5
each side of the window opening
(Note: contractor to provide as
secondary flashing)

Ulltraclad© UA4535 Locater Clip
fixed to each stud with Ulltraclad©
screws

45x18 mm cavity battens

Ulltraclad© weatherboards

Building underlay

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

Note: A sloped sill trimmer is required when the glazing
pocket of window / door frame is positioned back past the
line of the wall framing

Ullrich Aluminium Co. Ltd. 1 : 2 C.09
Ulltraclad© Aluminium Cladding
September 2012 Window Jamb on Sill

40x18 mm cavity battens

Ulltraclad© head flashing

Cut channel on both sides
to 70 mm. Turn down
channel floor 90° and trim
back to 20 mm

Ulltraclad© jamb flashing

Window head flashing cut
around jamb flashing. Seal
junction with cavity battens
and Ulltraclad© jamb
flashing

Note: Ulltraclad© Head Flashing to extend 80 mm past edge of
window or door joinery. Building underlay and lashing tape
omitted for clarity

Ullrich Aluminium Co. Ltd. C.10
Ulltraclad© Aluminium Cladding
September 2012 Head / Jamb On Cavity - Isometric

Building underlay folded into 40x18 mm cavity battens
opening
Ulltraclad© jamb flashing
Flexible flashing tape continue 50
mm onto face of wall and 100 min, Back of flashing bent forward
up each jamb approximately 10 mm to
divert any water to the back of
Sill support Bar for windows wider the Ulltraclad© weatherboard
than 600mm
Underlay strips to isolate
aluminium from treated
battens

Aluminium soaker each side
of opening to divert incidental
water to back to cladding
(Note: contractor to provide
as secondary flashing)

Ullrich Aluminium Co. Ltd. C.11
Ulltraclad© Aluminium Cladding
September 2012 Sill / Jamb On Cavity - Isometric

Underlay strips to isolate aluminium 15 Nog as required
from treated battens (Alternatively 35 min
use 'CAVIBAT' system) Airseal over PEF rod around all
flashing upstand sides of meter box
Ulltraclad© UA4535 Locater Clip 10 mm gap nominal
fixed to each stud with Ulltraclad© 10 mm cover Flexible flashing tape at corners
screws Metal meter box

Ulltraclad© weatherboards

45x18 mm cavity battens
Building underlay continuous
behind head flashing and into
opening
Ulltraclad© cavity vent strip

Second layer of building underlay
over head flashing upstand

Ulltraclad© UA4533 Head Flashing
with 5mm diameter drainage holes
drilled through base of flashing @
300 mm ctrs.

20x20 mm metal angle sealed and
riveted to meter box

Window head flashing 15° slope
(Note: Not supplied with Ulltraclad©
system - contractor to supply as
additional flashing)

5 mm gap between head flashings

Ullrich Aluminium Co. Ltd. 1 : 2 C.12
Ulltraclad© Aluminium Cladding
September 2012 Meter Box Head On Cavity

Ulltraclad© UA4532 Window
Flashing fixed to wall framing with
50 x 2.5 mm clouts @ 600 mm ctrs.

Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

45x18 mm cavity battens

Building underlay continuous
around opening

Ulltraclad© Weatherboards Metal meter box

Inseal 3259 tape between angle
and jamb flashing

20x20 mm metal angle sealed and
riveted to meter box

Flexible flashing tape 100 mm
minimum up jamb

Airseal over PEF rod around all
sides of meter box

10 mm gap nominal

Ullrich Aluminium Co. Ltd. 1 : 2 C.13
Ulltraclad© Aluminium Cladding
September 2012 Meter Box Jamb On Cavity

20x20 mm metal angle sealed and Metal meter box
riveted to meter box
Flexible flashing tape to sill and
Inseal 3259 tape between angle jambs
and jamb flashing
Airseal around all sides of meter
Ulltraclad© UA4532 Window box over PEF rod
Flashing fixed to wall framing with
50 x 2.5 mm clouts @ 600 mm ctrs. 10 mm gap nominal

Ulltraclad© UA4535 Locater Clip
fixed to each stud with Ulltraclad©
screws
Ulltraclad© weatherboards

45x18 mm cavity battens

Building underlay
Underlay strips to isolate aluminium
from treated battens (Alternatively
use 'CAVIBAT' system)

Ullrich Aluminium Co. Ltd. 1 : 2 C.14
Ulltraclad© Aluminium Cladding
September 2012 Meter Box Sill On Cavity

40x18 mm cavity battens Underlay strips to isolate
aluminium from treated
Building underlay carefully cut to battens
suit pipe.
Square of flexible flashing
Ulltraclad© weatherboard over tape to a min. of 100 mm
flashing tape, carefully cut to suit outside of pipe. Ensure seal
pipe. Seal with PVC flange and with pipe bandage
flexible sealant.
Pipe to have min. 5° fall to
outside

Flexible flashing tape
bandage min. 25 mm wide all
round pipe

Ullrich Aluminium Co. Ltd. C.15
Ulltraclad© Aluminium Cladding
September 2012 Pipe Penetration On Cavity - Isometric

Ulltraclad© weatherboards 35 mm min
clear gap
Ulltraclad© UA4535 Locater Clip
fixed to each stud with Ulltraclad© 75 mm min flashing leg
screws above bottom of weatherboard
Nog as required
Underlay strips to isolate aluminium
from treated battens (Alternatively Roofing underlay turned up under
use 'CAVIBAT' system) flashing

Building underlay lapped over Selected roofing with stop ends
flashing upstand
45x18 mm cavity battens

Ulltraclad© cavity vent strip
Ulltraclad© UA4533 Head Flashing
with 15mm drip edge and 5mm
diameter drainage holes drilled
through base of flashing @ 300
mm ctrs.

Apron flashing with 75 mm upstand
cover behind cladding

Note: Refer to E2/AS1 Table 7 for apron flashing cover dimensions

Ullrich Aluminium Co. Ltd. 1 : 2 C.16
Ulltraclad© Aluminium Cladding
September 2012 Roof / Wall Junction On Cavity

Underlay strips to isolate aluminium
from treated battens

Building underlay

48x18 mm cavity battens

Ulltraclad© weatherboards

Flashing tape or extra
layer of building underlay
over flashing

Flashing upstand behind
building underlay

Fall Apron flashing with

Selected roofing tapered stopend.

Weatherboards to be

carefully cut over stopend

& sealed

End of spouting must
finish 10 mm min. clear of
weatherboards

Selected spouting

Soffit
Fascia board

Note: Refer to E2/AS1 Table 7 for apron flashing cover dimensions

Ullrich Aluminium Co. Ltd. C.17
Ulltraclad© Aluminium Cladding
September 2012 Gutter Wall Junction On Cavity - Isometric

H3.1 treated timber packer 5° slope min Underlay to provide isolation
to form slope of metal flashing from
Note: Where top of board is See table 7 E2/AS1for treated timber
cut down - screw fix through flashing depth Metal capping flashing
board, ensure fixing is (Note: not supplied with
covered by flashing Ulltraclad© system -
contractor to supply as
Ulltraclad© weatherboards additional flashing)

45x18 mm cavity battens Metal capping to be fixed
Building underlay continuous with rivets to sides only
over framing
Ulltraclad© UA4535 Locater
Clip fixed to each stud with
Ulltraclad© screws

Underlay strips to isolate
aluminium from treated
battens (Alternatively use
'CAVIBAT' system)

Ullrich Aluminium Co. Ltd. 1 : 2 C.18
Ulltraclad© Aluminium Cladding
September 2012 Parapet On Cavity

12 mm min Building underlay

45x18 mm cavity battens Solid blocking
Ulltraclad© weatherboards
Underlay strips to isolate aluminium Bolt fixing in accordance
from treated battens (Alternatively with NZS3604:2011
use 'CAVIBAT' system)
Ulltraclad© UA4535 Locater Clip
fixed to each stud with Ulltraclad©
screws
12 mm H3.2 timber packer at fixing
locations

Deck joists

50x50x3 mm thick
EPDM washer to
suit, hole to fit
tightly around bolt

H3.2 timber
stringer

Ullrich Aluminium Co. Ltd. 1 : 2 C.19
Ulltraclad© Aluminium Cladding
September 2012 Deck Junction On Cavity

Ulltraclad© weatherboards 100 mm min finished floor level Interior lining
Ulltraclad© UA4535 Locater Clip to finished deck surface
fixed to each stud with Ulltraclad© 50 overhang Bottom plate over DPC
screws Floor structure
Underlay strips to isolate aluminium Deck waterproof
from treated battens (Alternatively membrane lapped up
use 'CAVIBAT' system) behind building underlay
45x18 mm cavity battens past over bottom plate
Building underlay Minimum 150mm upstand
Ulltraclad© cavity vent strip
Ulltraclad© UA4862 Starter Strip Corner fillet
fixed to bottom plate with 50 x 2.5
mm clouts @ 600 mm ctrs 1 : 2 C.20

Waterproof deck structure Waterproof Deck On Cavity

Ullrich Aluminium Co. Ltd.
Ulltraclad© Aluminium Cladding
September 2012

Ulltraclad© UA4535 Locater Clip 35 mm min5 Bottom plate
fixed to each stud with Ulltraclad© cover Flooring to finish 10 mm
screws 15 back from outside framing
Ulltraclad© weatherboards 35 mm min
cover Continuous boundary joists
45x18 mm cavity battens
Top plate
Underlay strips to isolate aluminium Interior lining
from treated battens (Alternatively
use 'CAVIBAT' system)

Ulltraclad© cavity vent strip

Building underlay lapped over
flashing upstand
Aluminium flashing 15° slope
(Note: Not supplied with Ulltraclad©
system - contractor to supply as
additional flashing)

Note: Where top of board is cut
down - screw fix though board,
ensure fixing is covered by flashing

45x18 mm cavity battens

Ullrich Aluminium Co. Ltd. Note: This detail is required to limit
Ulltraclad© Aluminium Cladding cavities to two storeys or 7m maximum.
September 2012 Refer E2/AS1 clause 9.1.9.4

1 : 2 C.21

Inter-Storey Junction On Cavity


Click to View FlipBook Version