ALUMINUM FLUTED ROUND POLES WITH DECORATIVE BASE
POLE ORDERING INFORMATION
5FRN2TYPICAL ORDER EXAMPLE: A125 14 N BRZ
Pole Series Material Height1 Mounting Pole Options
Tenon Mount Configuration Finish LAB - Less Anchor Bolts
Round Fluted Pole with 21-1/2" Tall Decorative Base A125 - .125 Aluminum 8' N – Tenon Mount BRZ – Bronze
4FRN2 A188 - .188 Aluminum 10' 4N - Tenon Mount BLK – Black
5FRN2 12' WHT – White
6FRN2 14' SVG - Satin Verde Green
Round Fluted Pole with 31-1/2" Tall Decorative Base 16' MSV - Metallic Silver
4FRN3 18'
5FRN3
6FRN3 Consult Pole Selection
Chart on opposite page
FOOTNOTES: POLES & BRACKETS
1 - Pole heights will have +/- 2" tolerance.
BOLT CIRCLE EPA INFORMATION
4", 5", & 6” FRN2 4", 5", & 6” FRN3 All poles are guaranteed to meet the EPA requirements listed. Pole
17"(432mm) diameter base plate 17"(432mm) diameter base plate manufacturer is not responsible if a pole order has a lower EPA
rating than the indicated wind-loading zone where the pole will be
180o located.
CAUTION: This guarantee does not apply if the
90o 270o pole/bracket/fixture combination is used to support any other
items such as flags, pennants, or signs, which would add stress
to the pole. Pole manufacturer cannot accept responsibility for
harm or damage caused in these situations.
Bolt Circle 0o - Access Door 0o - Access Door NOTE: Pole calculations include a 1.3 gust factor over steady
Anchor Bolt 11-1/2" (292mm) Dia. Bolt Circle 11-1/2" (292mm) Dia. Bolt Circle wind velocity. Example: poles designed to withstand 80 MPH
Size steady wind will withstand gusts to 104 MPH. EPAs are for
+/- 1-1/2" (38mm) +/- 1-1/2" (38mm) locations 100 miles away from hurricane ocean lines. Consult LSI
P for other areas. Note: Hurricane ocean lines are the Atlantic and
O Gulf of Mexico coastal areas. For applications in Canada and areas
11-1/2" +/- 1-1/2" 11-1/2" +/- 1-1/2" using code requirements other than AASHTO LTS-3-94, consult
(292mm +/- 38mm) (292mm +/- 38mm) factory.
3/4" dia. x 17" x 3" hook
3/4" dia. x 17" x 3" hook (19mm x 432mm x 76mm)
(19mm x 432mm x 76mm)
Anchor Bolt 3-1/2" +/- 1/4" 3-1/2" +/- 1/4"
Projection (89mm +/- 6mm) (89mm +/- 6mm)
Base Plate 17" dia. x 3/4" thk. 17" dia. x 3/4" thk.
Dimensions (432mm x 19mm) (432mm x 19mm)
Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
49
ALUMINUM ROUND POLES
DIMENSIONS RPN – POLE SHAFT - The pole shaft is extruded from seamless alloy aluminum. On tenon mount
N = 2-3/8" (60mm) poles, tenon is of high-strength pipe. Tenon N option is 2-3/8” O.D. x 4” tall. Tenon 4N
O.D. x 4" (102mm) option is 4” O.D. x 5” tall. Aluminum round poles are 4” and 5” in diameter.
Tall Tenon HAND HOLE - Covered and gasketed 2” x 4” non-reinforced hand-hole is located 12” above
bottom of pole base. For pole with greater EPA rating, reinforced hand hole is available
8'-20' 4N = 4" (102mm) as an option; consult factory. Optional festoon for GFI receptacle (with or without GFI Kit
(2.4m - 6.1m) O.D. x 5" (127mm) supplied) is available. Minimum height for location of festoon is 18” above standard hand
hole.
Tall Tenon
BASE - Pole base is cast from 356 alloy aluminum. Completed assembly is heat-treated to a
RPB3, RPB5 - T6 temper. Aluminum nut covers are included with anchor base.
Bolt-On Mount,
BASE COVERS - Aluminum nut covers are included with anchor base. Optional two-piece
2-Bolt Pattern decorative die-cast aluminum (GBC) base covers or optional one-piece spun aluminum
collars are available. Must be ordered separately.
Nut Covers
(Standard) ANCHOR BOLTS - Set of four anchor bolts conform to ASTM F1554 Grade 55. Each bolt is
provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and
POLES & BRACKETS Hand-hole are galvanized a minimum of 12” on the threaded end.
12" One-Piece Spun GROUND LUG - Ground lug is standard.
(305mm) Aluminum Collar GROUND FAULT CIRCUIT INTERRUPTER - Ground fault circuit interrupter kit is optional.
Standard
(Optional) Pole Preparation (festoon) with GFI Kit must be ordered. Specify location in feet above
base of pole and side orientation. Minimum height for location of festoon is 18” above
GBC Two-Piece 9-3/4” standard hand hole.
Decorative Cast (248mm) FINISHES - Baked-on polyester-powder finish provides one year limited warranty.
DETERMINING THE LUMINAIRE/POLE COMBINATION FOR YOUR APPLICATION:
Base Cover • Select luminaire from luminaire ordering information
(Optional) • Select bracket configuration if required
• Determine EPA value from luminaire/bracket EPA chart
15" • Select pole height
(381mm) • Select MPH to match wind speed in the application area (See windspeed map).
• Confirm pole EPA equal to or exceeding value from note above
DRILLING LOCATIONS Side “C” • Confirm total luminaire/bracket weight does not exceed maximum weight shown
Side “D” Side “B” in chart below
• Consult factory for special wind load requirements and banner brackets
POLE SELECTION CHART: 4" (102mm) and 5" (127mm) aluminum round poles
Side “A” (Hand-hole Side) Height EPA Outside Material Max Weight Bolt Structure
70 MPH 80 MPH 90 MPH 100 MPH Dimensions (lbs)1 Circle Weight (lbs)2
Sides A BC D 8' (2.4m)
Hand-hole X 10' (3.0m) 10.7 7.9 6.0 4.7 4" (102mm) 0.125 75 E 19
X 10' (3.0m)
Single X X 12' (3.7m) 8.1 5.9 4.3 3.3 4" (102mm) 0.125 75 E 22
X 12' (3.7m)
D180° X X 12' (3.7m) 15.4 11.5 8.9 7.1 5" (127mm) 0.125 100 F 27
12' (3.7m)
D90° X 14' (4.3m) 6.2 4.3 3.0 2.2 4" (102mm) 0.125 75 E 26
14' (4.3m)
T90° X X 14' (4.3m) 12.2 9.0 6.9 5.5 5" (127mm) 0.125 100 F 32
TN120o* X 14' (4.3m)
Q90° XX X 16' (4.9m) 15.5 11.5 8.9 7.1 5" (127mm) 0.156 100 F 38
16' (4.9m)
*Other two locations will be 120o to the left and right side of A. 16' (4.9m) 18.8 14.0 10.9 8.7 5" (127mm) 0.188 100 F 45
16' (4.9m)
18' (5.5m) 4.6 3.0 1.9 1.2 4" (102mm) 0.125 100 E 30
18' (5.5m)
18' (5.5m) 9.7 6.9 5.3 4.1 5" (127mm) 0.125 100 F 36
20' (6.1m)
20' (6.1m) 12.5 9.1 7.0 5.5 5" (127mm) 0.156 100 F 44
20' (6.1m)
15.3 11.2 8.7 6.9 5" (127mm) 0.188 100 F 52
3.2 1.9 1.0 0.5 4" (102mm) 0.125 100 E 33
7.4 5.1 3.8 3.0 5" (127mm) 0.125 100 F 41
9.8 6.9 5.3 4.1 5" (127mm) 0.156 100 F 50
12.2 8.7 6.7 5.3 5" (127mm) 0.188 100 F 58
5.6 3.7 2.7 2.0 5" (127mm) 0.125 100 F 45
7.7 5.2 3.9 3.0 5" (127mm) 0.156 100 F 55
9.7 6.8 5.1 4.0 5" (127mm) 0.188 100 F 65
4.1 2.4 1.7 1.2 5" (127mm) 0.125 100 F 50
5.9 3.8 2.8 2.0 5" (127mm) 0.156 100 F 61
7.6 5.2 3.8 2.9 5" (127mm) 0.188 100 F 72
LED ARRA EPA based on AASHTO LTS-3-94. For applications in Canada, areas using code requirements other than
AASHTO LTS-3-94, and for banner brackets, consult factory. Designs are limited to top-mounted and
Funding Compliant side-mount luminaires. Variations from sizes above are available, consult factory. Satisfactory performance
of poles is dependent upon the pole being properly attached to a supporting foundation of adequate design.
Project Name Refer to EPA information on next page. Maximum luminaire/bracket weight is shown on the above chart.
1- Maximum weight of fixtures/brackets to be mounted to pole.
50 Catalog # 2- Structure weight is a nominal value which includes the pole shaft and base plate.
Fixture Type © 2015
LSI INDUSTRIES INC.
ALUMINUM ROUND POLES
POLE ORDERING INFORMATION
5RPB5TYPICAL ORDER EXAMPLE: A188 20 S BRZ
Pole Series Material Height 3 Mounting Pole Options
Bolt-On Mount1 - See selection guide for patterns and Configuration Finish RHH - Reinforced Hand Hole4
fixture matches. A125 - .125 Aluminum 8' S - Single/Parallel BRZ – Bronze FP - Festoon Outlet Provision
4RPB3 - 3" Reduced Drilling Pattern A156 - .156 Aluminum 10' D180o - Double BLK – Black
5RPB3 - 3" Reduced Drilling Pattern A188 - .188 Aluminum 12' D90o - Double WHT – White Less GFI Kit5
4RPB5 - 5" Traditional Drilling Pattern 14' T90o - Triple SVG - Satin Verde Green FPG - Festoon Outlet Provision
5RPB5 - 5" Traditional Drilling Pattern 16' TN120o - Triple MSV - Metallic Silver
Tenon Mount - See selection guide for tenon and 18' Q90o - Quad With GFI Kit5
fixture/bracket matches. 20' LAB - Less Anchor Bolts
4RPN N – Tenon Mount
5RPN2 4N - Tenon Mount (Available
with 5RPN only. For 4"
poles, use 4RPSF below)
Greenlee Slipfit - Use with Greenlee Lifestyle CC, SC & CH Consult Pole Selection * POLES & BRACKETS
mounting styles. Enterprise, Intrepid & Lexington PT single Chart on opposite page
mounting styles 2
4RPSF
Greenlee Universal Bracket1 (No Drilling) - Use
with Lifestyle UCLS and UCLD180
4RPI
5RPI
FOOTNOTES: 4 - Reinforced hand-holes are 2-3/8” x 4” on 4” dia. round poles and 3” x 5” on 5”
1 - Standard pole cap provided. Domed Greenlee pole cap will ship with SA4 and SA5 Enterprise, dia. round poles. Both are located 18” above bottom of pole base.
Intrepid and Lexington fixtures, SA Lifestyle fixtures, BK SPT BO, BK MPT BO and UCL brackets. 5 - Specify location in feet above base of pole and side orientation. Minimum height is
2 - For Enterprise, Intrepid and Lexington D180o or other mounting configuration styles using BK 18” above standard hand hole.
SPT BO and BK MPT BO accessories, order 4RPB3 or 5RPB3 pole. 6 - Banner Brackets will add EPA to pole.
3 - Pole heights will have +/- 2" tolerance.
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description Order Number
4 / 5 GBC - Decorative Base Cover 483859CLR
4RSAC - 4" Round 1-Piece Spun Aluminum Collar 506859CLR
5RSAC - 5" Round 1-Piece Spun Aluminum Collar 506860CLR
BBB - Breakaway Banner Brackets6 Consult Factory6
BOLT CIRCLE EPA INFORMATION
All poles are guaranteed to meet the EPA requirements
4" (102mm) Round 5" (127mm) Round listed. Pole manufacturer is not responsible if a pole order
8-15/16" (226mm) Square Base Plate 9-5/8" (244mm) Square Base Plate has a lower EPA rating than the indicated wind-loading zone
where the pole will be located.
Bolt Bolt CAUTION: This guarantee does not apply if the
Holes Holes pole/bracket/fixture combination is used to support any
other items such as flags, pennants, or signs, which would
Bolt Bolt add stress to the pole. Pole manufacturer cannot accept
Circle Circle responsibility for harm or damage caused in these
0° Handhole situations.
0° Handhole NOTE: Pole calculations include a 1.3 gust factor over
steady wind velocity. Example: poles designed to withstand
7-1/2" (191mm) Dia. Bolt Circle 8-5/8" (219mm) Dia. Bolt Circle 80 MPH steady wind will withstand gusts to 104 MPH. EPAs
+/- 3/4" (19mm) +/- 7/8" (22mm) are for locations 100 miles away from hurricane ocean lines.
Consult LSI for other areas. Note: Hurricane ocean lines are
EF the Atlantic and Gulf of Mexico coastal areas. For
applications in Canada, areas using code
Bolt Circle 7-1/2" +/- 3/4" 8-5/8" +/- 7/8" requirements other than AASHTO LTS-3-94, and for
(191mm +/- 19mm) (219mm +/- 22mm) banner brackets, consult factory.
Anchor Bolt 3/4" dia. x 17" x 3" hook 3/4" dia. x 17" x 3" hook
Size (19mm x 432mm x 76 mm) (19mm x 432mm x 76 mm)
Anchor Bolt 3-1/4" 3-1/4"
Projection (83mm) (83mm)
Base Plate 8-15/16" sq. x 5/8" thk. 9-5/8" sq. x 5/8" thk.
Dimensions (226mm x 16mm) (244mm x 16mm)
Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
51
ALUMINUM ROUND HINGED BASE POLES
DIMENSIONS RHPN – POLE SHAFT - The pole shaft is extruded from seamless alloy aluminum. Tenon N option
N = 2-3/8" (60mm) O.D. is 2-3/8” O.D. x 4” tall. Tenon 4N option is 4” O.D. x 5” tall. Aluminum round poles are
4” and 5” in diameter.
x 4" (102mm)
Tall Tenon
8'-20' 4N = 4" (102mm)O.D. HAND HOLE - Round hinged poles are shipped standard without hand hole. An optional
(2.4m - 6.1m) x 5" (127mm) covered, gasketed, non-reinforced hand hole is available. Optional festoon for GFI
Tall Tenon receptacle (with or without GFI Kit supplied) is available.
RHPB3, RHPB5 - BASE - Hinged pole base is cast from 356 alloy aluminum. Completed assembly is heat-
Bolt-On Mount, treated to a T6 temper.
2-Bolt Pattern
BASE COVERS - Aluminum two-piece base cover is included.
Round Hinged ANCHOR BOLTS - Set of four anchor bolts conform to ASTM F1554 Grade 55. Each bolt
Base is provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end
and are galvanized a minimum of 12” on the threaded end.
POLES & BRACKETS GROUND LUG - Ground lug is standard.
Aluminum 2-Piece GROUND FAULT CIRCUIT INTERRUPTER - Ground fault circuit interrupter kit is optional.
Cast Base Cover Pole Preparation (festoon) with GFI Kit must be ordered. Specify location in feet above
(Standard) base of pole and side orientation. If optional hand hole ordered, minimum height for
location of festoon is 18” above hand hole. If no hand hole required, minimum height is
12” above bottom of pole base.
FINISHES - Baked-on polyester-powder finish provides one year limited warranty.
DRILLING LOCATIONS Side “C” DETERMINING THE LUMINAIRE/POLE COMBINATION FOR YOUR APPLICATION:
• Select luminaire from luminaire ordering information
• Select bracket configuration if required
• Determine EPA value from luminaire/bracket EPA chart
• Select pole height
• Select MPH to match wind speed in the application area (See windspeed map).
• Confirm pole EPA equal to or exceeding value from note above
• Confirm total luminaire/bracket weight does not exceed maximum weight
shown in chart below
• Consult factory for special wind load requirements and banner brackets
Side “D” Side “B”
POLE SELECTION CHART: 4" (102mm) and 5" (127mm) aluminum round hinged base poles
Height EPA Outside Material Max Weight Bolt Structure
70 MPH 80 MPH 90 MPH 100 MPH Dimensions (lbs)1 Circle Weight (lbs)2
Side “A” 8' (2.4m) 10.8 8.0 6.1 4.8 4" (102mm) 0.125 50 W 19
Sides A BC D 10' (3.0m) 8.2 5.9 4.4 3.3 4" (102mm) 0.125 50 W 22
Hinge X X 10' (3.0m) 15.5 11.6 9.0 7.2 5" (127mm) 0.125 50 W 27
X
Hand-hole (optional) X X 12' (3.7m) 6.3 4.4 3.1 2.2 4" (102mm) 0.125 50 W 26
X
Single X 12' (3.7m) 12.4 9.1 7.0 5.6 5" (127mm) 0.125 50 W 32
D180° X 12' (3.7m) 15.7 11.6 9.0 7.2 5" (127mm) 0.156 50 W 38
D90° X 12' (3.7m) 18.9 14.1 11.0 8.8 5" (127mm) 0.188 50 W 45
T90° X X 14' (4.3m) 4.7 3.1 2.0 1.3 4" (102mm) 0.125 50 W 30
TN120o* X 14' (4.3m) 9.8 7.0 5.4 4.2 5" (127mm) 0.125 50 W 36
Q90° XX X 14' (4.3m) 12.6 9.2 7.1 5.6 5" (127mm) 0.156 50 W 44
*Other two locations will be 120o to the left and right side of A. 14' (4.3m) 15.4 11.3 8.7 6.9 5" (127mm) 0.188 50 W 52
16' (4.9m) 3.4 2.0 1.1 0.5 4" (102mm) 0.125 50 W 33
16' (4.9m) 7.6 5.2 3.9 3.0 5" (127mm) 0.125 50 W 41
16' (4.9m) 10.0 7.1 5.4 4.2 5" (127mm) 0.156 50 W 50
16' (4.9m) 12.3 8.9 6.8 5.3 5" (127mm) 0.188 50 W 58
18' (5.5m) 5.7 3.7 2.7 2.0 5" (127mm) 0.125 75 W 45
18' (5.5m) 7.7 5.3 4.0 3.0 5" (127mm) 0.156 75 W 55
18' (5.5m) 9.8 6.8 5.2 4.0 5" (127mm) 0.188 75 W 65
20' (6.1m) 4.2 2.5 1.7 1.2 5" (127mm) 0.125 75 W 50
20' (6.1m) 6.0 3.9 2.8 2.1 5" (127mm) 0.156 75 W 61
20' (6.1m) 7.7 5.2 3.9 2.9 5" (127mm) 0.188 75 W 72
LED ARRA EPA based on AASHTO LTS-3-94. For applications in Canada and areas using code requirements other than
AASHTO LTS-3-94, consult factory. Designs are limited to top-mounted and side-mount luminaires.
Funding Compliant Variations from sizes above are available, consult factory. Satisfactory performance of poles is dependent
upon the pole being properly attached to a supporting foundation of adequate design.
Refer to EPA information on next page. Maximum luminaire/bracket weight is shown on the above chart.
1- Maximum weight of fixtures/brackets to be mounted to pole.
2- Structure weight is a nominal value which includes the pole shaft and base plate.
CAUTION: Raising or lowering of the pole requires adequate preparation. Do not underestimate the force
required to raise or lower poles with heavy luminaires at the top.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
52 Catalog #
ALUMINUM ROUND HINGED BASE POLES
POLE ORDERING INFORMATION
5RHPB5TYPICAL ORDER EXAMPLE: A188 20 S BRZ
Pole Series Material Height 3 Mounting Pole Options
Bolt-On Mount1 - See selection guide for patterns and Configuration Finish HH - Non-reinforced Gasketed
fixture matches. A125 - .125 Aluminum 8' S - Single/Parallel BRZ – Bronze
4RHPB3 - 3" Reduced Drilling Pattern A156 - .156 Aluminum 10' D180o - Double BLK – Black Hand Hole4
5RHPB3 - 3" Reduced Drilling Pattern A188 - .188 Aluminum 12' D90o - Double WHT – White FP - Festoon Outlet Provision
4RHPB5 - 5" Traditional Drilling Pattern 14' T90o - Triple SVG - Satin Verde Green
5RHPB5 - 5" Traditional Drilling Pattern 16' TN120o - Triple MSV - Metallic Silver Less GFI Kit5
Tenon Mount - See selection guide for tenon and 18' Q90o - Quad FPG - Festoon Outlet Provision
fixture/bracket matches. 20'
4RHPN N – Tenon Mount With GFI Kit5
5RHPN2 4N - Tenon Mount (Available LAB - Less Anchor Bolts
Greenlee Slipfit - Use with Greenlee Lifestyle CC, SC & CH
mounting styles. Enterprise, Intrepid & Lexington PT Single with 5RHPN only. For 4"
mounting styles 2 poles, use 4RHPSF below
4RHPSF
Greenlee Universal Bracket1 (No Drilling) - Use Consult Pole Selection * POLES & BRACKETS
with Lifestyle UCLS and UCLD180 Chart on opposite page
4RHPI
5RHPI
FOOTNOTES: 4 - Covered and gasketed 2” x 4” non-reinforced had-hole is located 12” above bottom of pole
1 - Standard pole cap provided. Domed Greenlee pole cap will ship with SA4 and SA5 Enterprise, Intrepid and base.
Lexington fixtures, SA Lifestyle fixtures, BK SPT BO, BK MPT BO and UCL brackets. 5 - Specify location in feet above base of pole and side orientation. If optional hand hole
2 - For Enterprise, Intrepid and Lexington D180o or other mounting configuration styles using BK SPT BO and ordered, minimum height for location of festoon is 18” above hand hole. If no hand hole
required, minimum height is 12” above bottom of pole base.
BK MPT BO accessories, order 4RPB3 or 5RPB3 pole.
3 - Pole heights will have +/- 2" tolerance.
BOLT CIRCLE EPA INFORMATION
All poles are guaranteed to meet the EPA requirements listed.
4" (102mm) & 5" (127mm) Round Hinged Pole manufacturer is not responsible if a pole order has a
12-5/8"(321mm) diameter base plate lower EPA rating than the indicated wind-loading zone where
the pole will be located.
(optional) CAUTION: This guarantee does not apply if the
pole/bracket/fixture combination is used to support any other
9-1/4" (235mm) Dia. Bolt Circle items such as flags, pennants, or signs, which would add
+/- 3/4"(19mm) stress to the pole. Pole manufacturer cannot accept
responsibility for harm or damage caused in these situations.
W NOTE: Pole calculations include a 1.3 gust factor over steady
wind velocity. Example: poles designed to withstand 80 MPH
Bolt Circle 9-1/4" +/- 3/4" steady wind will withstand gusts to 104 MPH. EPAs are for
(235mm +/- 19mm) locations 100 miles away from hurricane ocean lines. Consult
LSI for other areas. Note: Hurricane ocean lines are the
Anchor Bolt 3/4" dia. x 17" x 3" hook Atlantic and Gulf of Mexico coastal areas. For applications in
Size (19mm x 432mm x 76 mm) Canada and areas using code requirements other than
AASHTO LTS-3-94, consult factory.
Anchor Bolt 3-1/2"
Projection (89mm)
Base Plate 12-5/8" dia. x 3/4" thk.
Dimensions (321mm x 19mm)
Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
53
ALUMINUM ROUND TAPERED POLES
DIMENSIONS RTPN – POLE SHAFT - The pole shaft is spun from seamless alloy aluminum. On Tenon Mount
N = 2-3/8" (60mm) O.D. poles, tenon is 2-3/8” O.D. x 4” tall high-strength pipe.
18'-30'
(5.5m - 9.1m) x 4" (102mm) HAND HOLE - On listed poles 20’ and under, standard non-reinforced hand-hole is 2” x 4”.
Tall Tenon For poles with greater EPA rating, reinforced hand hole is available as an option; consult
factory. Listed poles 25’ and above have a 4” x 6” reinforced hand-hole as standard.
B2o-ltB-oOlntRPMTaPotBtuen5rtn,- Hand-hole gasket and cover are provided. Hand-hole is located 12” above pole base
on poles with 5” O.D. bottom and 18” above pole base on poles with 6”, 8” or 9” O.D.
bottom (see Pole Selection Chart below). Optional festoon for GFI receptacle (with or
without GFI Kit supplied) is available. Minimum height for location of festoon is 18”
above standard hand hole.
N(SuttaCnodvaerdrs) BASE - Pole base is cast from 356 alloy aluminum. Completed assembly is heat-treated to a
T6 temper. Aluminum nut covers are included with anchor base.
POLES & BRACKETS One-Piece Spun BASE COVERS - Aluminum nut covers are included with anchor base. Optional one-piece
Aluminum Collar round spun aluminum collars are available for poles with 5”, 6” or 8” O.D. bottom (see
Pole Selection Chart below). Must be ordered separately.
(Optional)
ANCHOR BOLTS - Set of four anchor bolts conform to ASTM F1554 Grade 55. Each bolt is
provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and
are galvanized a minimum of 12” on the threaded end.
12” (305mm) for GROUND LUG - Ground lug is standard.
5” Pole Bottom GROUND FAULT CIRCUIT INTERRUPTER - Ground fault circuit interrupter kit is optional.
18"(457mm) for
6”, 8” or 9” Pole Bottom Pole Preparation (festoon) with GFI Kit must be ordered. Specify location in feet above
base of pole and side orientation. Minimum height for location of festoon is 18” above
standard hand hole.
FINISHES - Baked-on polyester-powder finish provides one year limited warranty.
DRILLING LOCATIONS Side “C” DETERMINING THE LUMINAIRE/POLE COMBINATION FOR YOUR APPLICATION:
• Select luminaire from luminaire ordering information
Side “D” Side “B” • Select bracket configuration if required
• Determine EPA value from luminaire/bracket EPA chart
Side “A” (Hand-hole Side) • Select pole height
• Select MPH to match wind speed in the application area (See windspeed map).
• Confirm pole EPA equal to or exceeding value from note above
• Confirm total luminaire/bracket weight does not exceed maximum weight shown
in chart below
• Consult factory for special wind load requirements and banner brackets
Sides A BC D
Hand-hole X
Single X X
D180° X X POLE SELECTION CHART: aluminum round tapered poles
X
D90° X X Height EPA MPH100 MPH Pole Top Pole Bottom Material Max Wt Bolt Struct.
T90° X X MPH 90 O.D.1 O.D.1 (lbs)2 Circle Wt (lbs)3
18' (5.5m) 70 MPH 80
18' (5.5m) 3.0 (76mm) 5.0 (127mm) F 40
TN120o* X 18' (5.5m) 6.5 4.4 3.1 2.2 4.0 (102mm) 6.0 (152mm) 0.125 100 X 59
Q90° XX X 20' (6.1m) 4.0 (102mm) 6.0 (152mm) 0.156 100 X 70
*Other two locations will be 120o to the left and right side of A. 20' (6.1m) 15.4 11.3 8.6 6.8 3.0 (76mm) 5.0 (127mm) 0.188 100 F 42
20' (6.1m) 4.0 (102mm) 6.0 (152mm) 0.125 100 X 63
25' (7.6m) 18.9 14.0 10.7 8.5 4.0 (102mm) 6.0 (152mm) 0.156 100 X 74
25' (7.6m) 4.5 (114mm) 8.0 (203mm) 0.188 100 Y 96
30' (9.1m) 5.1 3.3 2.1 1.3 4.5 (114mm) 8.0 (203mm) 0.156 150 Y 113
30' (9.1m) 4.5 (114mm) 9.0 (229mm) 0.188 150 Z 127
30' (9.1m) 12.7 9.1 6.8 5.3 4.5 (114mm) 9.0 (229mm) 0.156 150 Z 149
4.5 (114mm) 8.0 (203mm) 0.188 150 Y 174
15.8 11.4 8.6 6.8 0.250 150
19.4 14.2 10.8 8.5
24.2 17.8 13.7 10.8
18.8 13.6 10.3 8.0
23.7 17.4 13.3 10.4
24.2 17.7 13.6 10.7
EPA based on AASHTO LTS-3-94. For applications in Canada and areas using code requirements other than
AASHTO LTS-3-94, consult factory. Designs are limited to top-mounted and side-mount luminaires.
Variations from sizes above are available, consult factory. Satisfactory performance of poles is dependent
upon the pole being properly attached to a supporting foundation of adequate design.
Refer to EPA information on next page. Maximum luminaire/bracket weight is shown on the above chart.
1- Variations from sizes above are available.
2- Maximum weight of fixtures/brackets to be mounted to pole.
3- Structure weight is nominal value which includes the pole shaft and base plate.
LED ARRA
Funding Compliant
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
54 Catalog #
ALUMINUM ROUND TAPERED POLES
POLE ORDERING INFORMATION
RTPB5TYPICAL ORDER EXAMPLE: A156 25 S BRZ
Pole Series Material Height 2 Mounting Pole Options
Bolt-On Mount1 - See selection guide for patterns and fixture A125 - .125 Aluminum 18' - 17'-8" Configuration Finish RHH - Reinforced Hand-hole
matches. A156 - .156 Aluminum 20' - 19'-8" S - Single/Parallel BRZ – Bronze
RTPB5 - 5" Traditional Drilling Pattern A188 - .188 Aluminum 25' - 24'-8" D180o - Double BLK – Black for poles 20’ and under3
A250 - .250 Aluminum 30' - 29'-8" D90o - Double WHT – White FP - Festoon Outlet Provision
T90o - Triple SVG - Satin Verde Green
TN120o - Triple MSV - Metallic Silver Less GFI Kit4
Q90o - Quad FPG - Festoon Outlet Provision
Tenon Mount - See selection guide for tenon and
fixture/bracket matches. N – Tenon Mount With GFI Kit4
RTPN LAB - Less Anchor Bolts
Consult Pole Selection
Chart on opposite page
FOOTNOTES: 3 - Reinforced hand-holes are 3” x 5” on poles with 5” or 6” O.D. bottom and located 18” above pole POLES & BRACKETS
1 - Standard pole cap provided. base.
2 - Pole heights will have +/- 2" tolerance.
4 - Specify location in feet above base of pole and side orientation. Minimum height is 18" above
standard hand hole.
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description Order Number
5RSAC - Round 1-Piece Spun Aluminum Collar for RTP w/5” bottom 505647CLR
6RSAC - Round 1-Piece Spun Aluminum Collar for RTP w/6” bottom 505648CLR
8RSAC - Round 1-Piece Spun Aluminum Collar for RTP w/8” bottom 505649CLR
BOLT CIRCLE
5" (127mm) O.D. Pole Bottom 6" (152mm) O.D. Pole Bottom 8" (203mm) O.D. Pole Bottom 9" (229mm) O.D. Pole Bottom
9-5/8" (244mm) square base plate 10-5/16" (262mm) square base plate 12-1/16"(306mm) square base plate 12-1/2" (317mm) square base plate
Bolt Bolt Bolt Bolt
Holes Holes Holes Holes
Bolt Bolt Bolt Bolt
Circle Circle Circle Circle
0° Handhole 0° Handhole 0° Handhole
9-1/2" (241mm) Dia. Bolt Circle 11-5/8" (295mm) Dia. Bolt Circle 0° Handhole
8-5/8" (219mm) Dia. Bolt Circle +/- 3/4" (19mm) +/- 3/8" (9mm) 13-1/4" (337mm) Dia. Bolt Circle
+/- 7/8" (22mm)
+/- 3/4" (19mm)
F XY Z
Bolt Circle 8-5/8" +/- 7/8" 9-1/2" +/- 3/4" 11-5/8" +/- 3/8" 13-1/4" +/- 3/4"
(219mm +/- 22mm) (241mm +/- 19mm) (295mm +/- 9mm) (337mm +/- 19mm)
1" dia. x 36" x 4" hook
Anchor Bolt 3/4" dia. x 17" x 3" hook 3/4" dia. x 17" x 3" hook 1" dia. x 36" x 4" hook (25mm x 914mm x 102mm)
Size (19mm x 432mm x 76 mm) (19mm x 432mm x 76 mm) (25mm x 914mm x 102mm)
4-1/8"
Anchor Bolt 3-1/4" 3-1/2" 4-1/8" (105mm)
Projection (83mm) (89mm) (105mm) 12-1/2" sq. x 1-1/4" thk.
(317mm x 32mm)
Base Plate 9-5/8" sq. x 5/8" thk. 10-5/16" sq. x 5/8" thk. 12-1/16" sq. x 3/4" thk.
Dimensions (244mm x 16mm) (262mm x 16mm) (306mm x 19mm)
Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates.
EPA INFORMATION NOTE: Pole calculations include a 1.3 gust factor over steady wind velocity. Example: poles
All poles are guaranteed to meet the EPA requirements listed. Pole manufacturer is not responsible if a designed to withstand 80 MPH steady wind will withstand gusts to 104 MPH. EPAs are for locations
pole order has a lower EPA rating than the indicated wind-loading zone where the pole will be located. 100 miles away from hurricane ocean lines. Consult LSI for other areas. Note: Hurricane ocean
CAUTION: This guarantee does not apply if the pole/bracket/fixture combination is used to support any lines are the Atlantic and Gulf of Mexico coastal areas. For applications in Canada and areas using
other items such as flags, pennants, or signs, which would add stress to the pole. Pole manufacturer code requirements other then AASHTO LTS-3-94, consult factory.
cannot accept responsibility for harm or damage caused in these situations.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
55
ALUMINUM SQUARE POLES (SOFT CORNER)
DIMENSIONS SQN – POLE SHAFT - The soft corner pole shaft is extruded from seamless alloy aluminum. On
N = 2-3/8" (60mm) Tenon Mount poles, tenon is 2-3/8” O.D. x 4” tall high-strength pipe. Aluminum straight
8'-35' O.D. x 4" (102mm) poles are 4”, 5” and 6” square.
(2.4m - 10.7m)
Tall Tenon HAND-HOLE - On 4” square poles, standard hand hole is 2” x 4” located 12” up from
SQB3, SQB5 – bottom of base plate. On 5” square poles, standard hand hole is 2” x 4” located 14” up
Bolt-On Mount from bottom of base plate. On 6” square poles, standard hand hole is 2-5/8” x 5” located
2-Bolt Pattern 18” up from bottom of base plate. Hand hole gasket is provided. Optional festoon for GFI
receptacle (with or without GFI Kit supplied) is available. Minimum height for location of
festoon is 18” above standard hand hole.
BASE - Pole base is cast from 356 alloy aluminum. Completed assembly is heat-treated to a
T6 temper. Tamper-resistant aluminum nut cover discs are included with anchor base.
SQI – BASE COVERS - Tamper-resistant aluminum nut cover discs are included with anchor base.
No Mounting Optional two-piece square cast base covers available. Must be ordered separately.
POLES & BRACKETS Hand-hole Holes ANCHOR BOLTS - Set of four anchor bolts conform to ASTM F1554 Grade 55. Each bolt is
provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and
Hand Hole Heights are galvanized a minimum of 12” on the threaded end.
4" (102mm) = 12" (305mm) Standard
5" (127mm) = 14" (356mm) Standard GROUND LUG - Ground lug is standard.
6" (152mm) = 18" (457mm) Standard
GROUND FAULT CIRCUIT INTERRUPTER - Ground fault circuit interrupter kit is optional.
Nut Covers Discs Square Two-Piece Pole Preparation (festoon) with GFI Kit must be ordered. Specify location in feet above
(Standard) Cast Base Cover base of pole and side orientation. Minimum height for location of festoon is 18” above
standard hand hole.
(Optional)
FINISHES - Baked-on polyester-powder finish provides one year limited warranty.
DRILLING LOCATIONS Side “C” DETERMINING THE LUMINAIRE/POLE COMBINATION FOR YOUR APPLICATION:
• Select luminaire from luminaire ordering information
• Select bracket configuration if required
• Determine EPA value from luminaire/bracket EPA chart
• Select pole height
• Select MPH to match wind speed in the application area (See windspeed map).
• Confirm pole EPA equal to or exceeding value from note above
• Confirm total luminaire/bracket weight does not exceed maximum weight shown
in chart below
• Consult factory for special wind load requirements
POLE SELECTION CHART: 4" (102mm), 5" (127mm) and 6" (152mm) aluminum square poles
Height EPA Outside Material Max Weight Bolt Structure
70 MPH 80 MPH 90 MPH 100 MPH Dimensions (lbs)1 Circle Weight (lbs)2
Side “D” Side “B” 8' (2.4m) 24.3 18.2 14.0 10.9 4" (102mm) 0.125 350 G 24
10' (3.0m) 18.9 13.9 10.5 8.0 4" (102mm) 0.125 260 G 28
12' (3.7m) 14.7 10.6 7.7 5.7 4" (102mm) 0.125 260 G 33
14' (4.3m) 11.9 8.3 5.8 4.1 4" (102mm) 0.125 200 G 37
15' (4.6m) 8.3 5.7 3.8 2.6 4" (102mm) 0.125 200 G 39
Side “A” (Hand-hole Side) 16' (4.9m) 7.3 4.8 3.1 1.9 4" (102mm) 0.125 200 G 42
AB
Sides X C D 16' (4.9m) 12.3 8.6 6.1 4.3 4" (102mm) 0.188 200 G 59
Hand-hole X X X
Single X X 18' (5.5m) 5.9 3.6 2.1 N/A 4" (102mm) 0.125 100 G 46
D180° X X
D90° XX X 18' (5.5m) 10.1 6.8 4.6 3.0 4" (102mm) 0.188 150 G 66
T90° XX
Q90° 18' (5.5m) 18.0 12.7 9.0 6.4 5" (127mm) 0.188 260 H 85
20' (6.1m) 4.1 2.1 N/A N/A 4" (102mm) 0.125 150 G 51
20' (6.1m) 8.1 5.2 3.1 1.7 4" (102mm) 0.188 150 G 73
20' (6.1m) 15.4 10.5 7.1 4.7 5" (127mm) 0.188 150 H 93
20' (6.1m) 24.8 17.4 12.3 8.7 6" (152mm) 0.188 150 I 114
20' (6.1m) 33.8 24.3 17.8 13.2 6" (152mm) 0.250 260 I 148
25' (7.6m) 9.5 5.6 3.0 1.0 5" (127mm) 0.188 100 H 115
25' (7.6m) 15.8 10.1 6.1 3.3 6" (152mm) 0.188 260 I 139
25' (7.6m) 23.3 15.8 10.7 7.0 6" (152mm) 0.250 260 I 182
30' (9.1m) 14.2 8.6 4.8 2.0 6" (152mm) 0.250 260 I 216
32' (9.8m) 12.2 6.9 3.2 N/A 6" (152mm) 0.250 150 I 229
35' (10.7m) 9.1 4.2 N/A N/A 6" (152mm) 0.250 100 I 250
LED ARRA EPA based on commercial criteria. For applications in Canada and areas using code requirements other than
commercial criteria, consult factory. Designs are limited to top-mounted and side-mount luminaires.
Funding Compliant Variations from sizes above are available, consult factory. Satisfactory performance of poles is dependent
upon the pole being properly attached to a supporting foundation of adequate design.
Refer to EPA information on next page. Maximum luminaire/bracket weight is shown on the above chart.
1- Maximum weight of fixtures/brackets to be mounted to pole.
2- Structure weight is a nominal value which includes the pole shaft and base plate.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
56 Catalog #
ALUMINUM SQUARE POLES (SOFT CORNER)
POLE ORDERING INFORMATION
5SQB5TYPICAL ORDER EXAMPLE: A188 25 S BRZ
Pole Series Material Height2 Mounting Pole Options
Configuration4 Finish FP - Festoon Outlet Provision
Bolt-On Mount - See selection guide for patterns and fixture matches. A125 - .125 Aluminum 8' S - Single/Parallel BRZ – Bronze
4SQB3 - 3" Reduced Drilling Pattern A188 - .188 Aluminum 10' D180o - Double BLK – Black Less GFI Kit5
5SQB3 - 3" Reduced Drilling Pattern A250 - .250 Aluminum 12' D90o - Double WHT – White FPG - Festoon Outlet Provision
4SQB5 - 5" Traditional Drilling Pattern 14' T90o - Triple SVG - Satin Verde Green
5SQB5 - 5" Traditional Drilling Pattern 16' Q90o - Quad MSV - Metallic Silver With GFI Kit5
6SQB5 - 5" Traditional Drilling Pattern 18' N – Tenon Mount LAB - Less Anchor Bolts
20' *
25'
Tenon Mount - See selection guide for tenon and 30'3
fixture/bracket matches. 32'3
4SQN 35'3
5SQN
6SQN
Consult Pole Selection POLES & BRACKETS
Chart on opposite page
Internal Slip-fitter1
No mounting holes or pole caps - Use with BKA 4ISF,
BKA 5ISF, BKA X4ISF & BKA X5ISF
4SQI
5SQI
FOOTNOTES: 4 - TN120o mounting configuration not available.
1 - See Area Lighting Brackets - Bolt-on and XAS3/XAMU Area Lighting Brackets pages for Internal Slip-fitter brackets. 5 - Specify location in feet above base of pole and side orientation.
2 - Pole heights will have +/- 2" tolerance.
3 - Pole includes factory installed vibration damper. Minimum height is 18" up from standard hand hole.
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description Order Number
4DABC - 4" Square Cast 2-Piece Base Cover 505605CLR
5DABC - 5" Square Cast 2-Piece Base Cover 505606CLR
6DABC - 6" Square Cast 2-Piece Base Cover 505608CLR
BOLT CIRCLE EPA INFORMATION
4" (102mm) Square 5" (127mm) Square 6" (152mm) Square All poles are guaranteed to meet the EPA requirements listed. Pole
12-3/4" (324mm) Square Base Plate manufacturer is not responsible if a pole order has a lower EPA
9-15/16" (252mm) Square Base Plate 11-9/16" (294mm) Square Base Plate rating than the indicated wind-loading zone where the pole will be
located.
Bolt Circle 9" (229mm) Dia. Bolt Circle 11" (279mm) Dia. Bolt Circle 12-1/2" (318mm) Dia. Bolt Circle CAUTION: This guarantee does not apply if the
Anchor Bolt +/- 1/2” (13mm) +/- 1/2” (13mm) +/- 7/16” (11mm) pole/bracket/fixture combination is used to support any other
Size G H I items such as flags, pennants, or signs, which would add stress
Anchor Bolt 9" +/- 1/2" 11" +/- 1/2" 12-1/2" +/- 7/16" to the pole. Pole manufacturer cannot accept responsibility for
Projection harm or damage caused in these situations.
(229mm +/- 13mm) (279mm +/- 13mm) (318mm +/- 11mm) NOTE: Pole calculations include a 1.3 gust factor over steady
3/4" dia. x 17" x 3" hook 3/4" dia. x 17" x 3" hook 1" dia. x 36" x 4" hook wind velocity. Example: poles designed to withstand 80 MPH
(19mm x 432mm x 76 mm) (19mm x 432mm x 76 mm) (25mm x 914mm x 102mm) steady wind will withstand gusts to 104 MPH. EPAs are for
locations 100 miles away from hurricane ocean lines. Consult LSI
3-1/8" 3-1/4" 4" for other areas. Note: Hurricane ocean lines are the Atlantic and
(79mm) (83mm) (102mm) Gulf of Mexico coastal areas. For applications in Canada, and
areas using code requirements other than commercial criteria,
consult factory.
Base Plate 9-15/16" sq. x 3/8" thk. 11-9/16" sq. x 1/2" thk. 12-3/4" sq. x 9/16" thk.
Dimensions (252mm x 10mm) (294mm x 13mm) (324mm x 14mm)
Note: Base plate illustrations may change without notice. Do not use for setting anchor bolts. Consult factory for the base plate templates.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
57
LSI ABOLITE NOSTALGIC POLES 8' (2.4m) 9-1/2"
10' (3m) (241mm)
Nostalgic Design 12' (3.7m) Bolt 12-1/8" O.D.
(308mm)
4” Aluminum Pole Specifications: Center
• P ole shaft is aluminum tubing welded
Hand-hole
to a cast aluminum base.
POLES & BRACKETS • End of pole is designed for use with
Shepherd’s Crook or other optional
pole brackets. All brackets must slip fit
over 4” O.D. pole.
• Standard finish is textured white
baked-on powder coating. Other
finishes are optional. Poles are
furnished with anchor bolts with zinc
plated double nut washers. Galvanized
anchor bolts are standard. Anchor
bolts conform to ASTM-A36 with a
minimum yield strength of 36,000 PSI.
• Hand-hole is 9" above base.
Foundation By Other
4" ALUMINUM POLE RATING
Height Pole Description EPA 4NOS ALUM 8 S WHT 8’ Pole-Aluminum with 4”
Series 80 MPH 90 MPH 100 MPH Round Shaft and Nostalgic
8' 4NOS 70 MPH Cast Base*
10' 4NOS 18.3 14.3 11.5
12' 4NOS ALUM 24.1 12.6 9.7 7.7
9.2 7 5.4
ALUM 16.8 4NOS ALUM 10 S WHT 10’ Pole-Aluminum with 4”
12.5 Round Shaft and Nostalgic
ALUM Cast Base*
Nostalgic pole weights: 8’: 31-1/2 lbs. 10’: 38-1/4 lbs. 12’: 41 lbs.
4NOS ALUM 12 S WHT 12’ Pole-Aluminum with 4”
Round Shaft and Nostalgic
Bolt Circle Cast Base*
Bolt Slotted *NOTE: Base plate cast into base
Circle 9-1/2"
Anchor Bolt Size 1/2" x 18"
Anchor Bolt Projection
Base Plate Thickness 3"
1/2"
Note: B ase plate illustrations may change without notice. Do not use for setting anchor
bolts. Consult factory for the base plate templates.
LED ARRA
Funding Compliant Fixture Type © 2015
LSI INDUSTRIES INC.
Project Name
58 Catalog #
LSI ABOLITE POLES
Straight Round Design
Steel Pole Specifications: Steel Pole Rating
• P ole shaft is electro-welded ASTM-A500 Grade B 4" steel tubing with a
Height Pole Description EPA
minimum yield strength of 46,000 PSI. 8' Series 70 MPH 80 MPH 90 MPH 100 MPH
• B ase is ASTM-A36 hot-rolled steel plate with a minimum yield strength 10' 4RPSF
12' 4RPSF S10G 24.1 18.3 14.1 11.2
of 36,000 PSI. 4RPSF S10G 18.6 13.8 10.6 8.3
• S tandard finish is textured white baked-on powder coating. Other S10G 14.7 10.8 8.1 6.2
finishes are optional. Steel pole weights: 4" Dia. 10 Ga. is approximately 10 lbs. per ft.
• P oles are available with anchor bolts with zinc plated double nuts and
Bolt Circle
washers. Galvanized anchor bolts are optional. Anchor bolts conform
with ASTM F1554-07a grade 55 with a minimum yield strength of Bolt Slotted POLES & BRACKETS
55,000 PSI. Anchor bolts must be ordered separately. Circle 8"
• Hand-hole is 12" above pole base. Anchor Bolt Size
• W ill accept commercial postline ballast. CFL only. MH provided by Anchor Bolt Projection 3/4" x 30"
others. Base Plate Thickness 3-1/4"
• Ground lug is standard. 3/4"
• Cast aluminum base covers available. Note: B ase plate illustrations may change without notice. Do not use for setting
anchor bolts. Consult factory for the base plate templates.
4"
4" (102mm) square (102mm) 8' (2.4m) 4RPSF S10G 8 * WHT 8' Pole–Steel 4" Round (Specify Color)
10-1/8" (257mm) sq. 10' (3m) 4RPSF S10G 10 * WHT 1 0' Pole–Steel 4" Round (Specify Color)
O.D. 12' (3.7m) 4RPSF S10G 12 * WHT 1 2' Pole–Steel 4" Round (Specify Color)
11" (279mm) Dia. Bolt Circle Optional
Cast Base Cover 12" American Innovation ARRA
(see accessories) (305mm) American Made
Funding Compliant
ACCESSORIES
NOTE: Consult factory for Projection GBC – 9-3/4”
availability of DuraGrip® Plus Cast Decorative (248mm)
(specify “DGP”) for steel poles. Foundation Base Cover 15"
By Other (381mm)
Aluminum Pole Specifications: ALUMINUM POLE RATING GBC 4 5
• P ole shaft is 6063-T6 grade 4" aluminum extrusion. Height Pole Description EPA
80 MPH 90 MPH 100 MPH
• Base is 356-T6 aluminum. Series 70 MPH
8.42 6.75 5.42
• Standard finish is Satin Anodized Aluminum. Gloss White, Black, and Red 8' RLM A125 12.8 6.33 4.92 3.92
powder coated finishes are optional. Consult factory for lead times. 10' RLM A125 9.8 4.75 3.58 2.75
12' RLM A125 7.6
• Poles are furnished with galvanized anchor bolts, cast base cover, Aluminum pole weights: 4" Dia. 10 Ga. is approximately 10 lbs. per ft.
double nuts and washers.
• H and-hole is 12" above pole base. Bolt Circle
• Will accept commercial postline ballast. CFL only. MH provided by Bolt Slotted
others. Circle 9-1/4"
Anchor Bolt Size 5/8" x 16"
• Ground lug is standard. Anchor Bolt Projection 2-3/4"
Base Plate Thickness 3/4"
• Base cover is square fabricated 4"
aluminum. (102mm) Note: B ase plate illustrations may change without notice. Do not use for setting anchor
bolts. Consult factory for the base plate templates.
O.D.
4" round 8' (2.4m) RLM 4RD A125 8 S SAA 8' Pole–Aluminum 4" Round with Square Base
8-1/2" sq. 10' (3m) Cover-Satin Anodized Aluminum*
8-5/8” sq. 12' (3.7m)
5” O.H. RLM 4RD A125 10 S SAA 10’ Pole–Aluminum 4" Round with Square Base
12" Cover-Satin Anodized Aluminum*
(305mm)
9-1/4" Bolt Circle RLM 4RD A125 12 S SAA 12’ Pole–Aluminum 4" Round with Square
Base Cover-Satin Anodized Aluminum*
Projection
ARRA Foundation *Note: Also available with Gloss Black, White or Red powder finish-consult factory.
By Other
Funding Compliant
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
59
SELECTION GUIDE FOR ROUND POLES AND SQUARE POLES
BOLT-ON MOUNT
3” REDUCED 2X 9/16” - 7/8” SLOT 5”TRADITIONAL 2-1/2” 9/16” DIA. HOLES
DRILLING PATTERN 1-1/16” DRILLING PATTERN (64mm) (TYP. 2 PLCS.)
(27mm) 3/4” DIA. HOLE
3-1/2” 4-5/8”
2-1/8” (89mm) (117mm)
(54mm) Ø 5/8”
1-1/2”
(38mm)
Use when mounting the below fixtures & bracket/fixture combinations: Use when mounting the below fixtures & bracket/fixture combinations:
ROUND POLES - 4RPB3 / 5RPB3 ROUND & SQUARE POLES - 4RPB5/5RPB5/4SQB5/5SQB5/6SQB5
• XLCS & XLCM (requires X4RPP or X5RPP) Round pole plate is required on Round Poles, except for HFSH, HFSV & HFR fixtures.
POLES & BRACKETS • PASU, XASU & XAMU (requires X4RPP or X5RPP) CH2HM CHH CT2H
• XPMAR Option on XPWS3, XCHWM3, XGBWM3 & PWM CTL CVF GFM
• SA4 & SA5 Mounting Styles on XENM, ENS, ENM, GFR HFR PTH
& Lifestyle XLS & XLM
PTHS XCHM3 XGBM
• BK SPT BO 4 & BK SPT BO 5 Accessories in Single, D180 or
other multiple mounting configurations on ENS & LXS XPT3 XPTS3 XSB
• BK MPT BO 4 & BK MPT BO 5 Accessories in Single, D180 or PMA (for Square Pole) & PMAR (for Round Pole) Options on CHWS,
other multiple mounting configurations on XCN3, XENM, CHWM, GBWS, GBWM, HIWSD, HIWS and PTWS
XLXM, ENM & LXM
SQUARE POLES - 4SQB3 / 5SQB3
• PASU • XAMU
• XASU • XPMA Option on XPWS3,
• XLCS/XLCM XCHWM3, XGBWM3 & PWM
ROUND POLES AND SQUARE POLES WITH TENON MOUNT
N TENON MOUNTING CONFIGURATION 5” DIAMETER ROUND POLES WITH 4N TENON MOUNTING
CONFIGURATION
4RPN / 5RPN / 4SQN / 5SQN / 6SQN N = 2-3/8” O.D. 5RPN with 4N Tenon Configuration
with N Tenon Configuration X
4N = 4” O.D.
4-3/4” tall X
Select this Tenon Mounting Configuration to use with vertically 4-7/8” tall
mounted tenon brackets shown on pages titled -
4N Tenon Mount Configuration is available with 5RPN only. (See 4RPSF
• Area Lighting Brackets - Tenon Mount for 4” poles). Select to use with:
• Flood Lighting Brackets • Lifestyle CH mounting styles
• Constitution, Enterprise & Lexington PT Single mounting
• PASU/XASU/XAMU Area Light Brackets
styles (For D180 or other mounting configuration styles requiring BK
• LED Roadway Light Mast Arms SPT BO or BK MPT BO accessories, see Bolt-on Mount 4RPB3 /
5RPB3 drilling pattern section.)
Subject to change. Consult factory.
LED ARRA
Funding Compliant Fixture Type © 2015
LSI INDUSTRIES INC.
Project Name
60 Catalog #
WINDSPEED MAP
POLES & BRACKETS
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
61
AREA LIGHT BRACKETS - 3” REDUCED DRILL PATTERN (XASU/XAMU/PASU/XLCS/XLCM)
BOLT ON BRACKETS (with 3” Reduced Drill Pattern)
EXTENSION ARM - Use this 6" extension arm ROUND POLE PLATE - For mounting fixtures to round poles
to position the fixture further from the pole.
BKA-XBO-EC-6-CLR X4RPP - For 4" Round Poles Order Number
Note: PASU/XASU/XAMU can be mounted X5RPP - For 5" Round Poles 379967CLR
in any drilling configuration (D180, D90, etc.) 379968CLR
without the use of this arm. Order Number 382136CLR
WALL MOUNT PLATE - Order Number 382132CLR
BKS XBO WM * CLR
POLES & BRACKETS 8" x 8"
(203mm x 203mm)
TENON BRACKETS (with 3” Reduced Drill Pattern)
BKA-XNM-*-CLR - Tenon mount fitter slip-fits 2-3/8" O.D. tenon
(2.0 pipe tenon).
10-3/4”
(273mm)
BKA-XNM-S or D180-*-CLR BKA-XNM-D90, T90 or Q90-*-CLR
Single/D180 D90/T90/Q90
(Drilled 2 Sides) (Drilled 4 Sides)
INTERNAL SLIP-FITTER - Fits 4" (102mm) or 5" (127mm) SQI square steel
poles with wall thickness of 11ga. (0.120"-3mm) or 7ga. (0.180"-5mm)
17” BKA-X4ISF-D180-*-CLR
(432mm) BKA-X4ISF-Q90-*-CLR
BKA-X5ISF-D180-*-CLR
9-3/4” BKA-X5ISF-Q90-*-CLR
(248mm)
RETROFIT BRACKETS - Mounting adaptor plates convert poles with existing 2-, 3-, and 4-hole LSI drilling patterns to use with fixtures with 3”
reduced drill pattern.
BKS-XBO-ADP-2H-CLR - To convert 2-hole 5” BKS-XBO-ADP-2H-CLR BKS-XBO-ADP-2H-CLR-EC6 BKS-XBO-ADP-3H-CLR BKS-XBO-ADP-4H-CLR
traditional LSI drilling pattern used with Challenger, 5-9/16” x 2-5/8” Mounting Bracket w/EC6 Arm 4-1/2” x 3-3/4” 4-3/4” x 3-3/4”
Greenbriar, etc. on round or square poles. Order
Number 388239CLR
BKS-XBO-ADP-2H-CLR-EC6 - To convert 2-hole 5”
traditional LSI drilling pattern and with 6" extension arm
and proper hardware for use with round or square
poles.
Order Number 388241CLR
BKS-XBO-ADP-3H-CLR1 - To convert 3-hole LSI drilling FOOTNOTES:
pattern on square poles. 1- When ordering adaptors for 3- and 4-hole drilled square poles, ordering a replacement
Order Number 388059CLR cap is also recommended due to the aging of the existing plastic pole cap.
BKS-XBO-ADP-4H-CLR1 - To convert 4-hole LSI drilling
pattern on square poles.
Order Number 388060CLR
LED ARRA
Funding Compliant Fixture Type © 2015
LSI INDUSTRIES INC.
Project Name
62 Catalog #
AREA LIGHT BRACKETS - 3” REDUCED DRILL PATTERN (XASU/XAMU/PASU/XLCS/XLCM)
BRACKET ORDERING INFORMATION
Bracket Bracket Bracket Length Bracket Finish Options EPA Estimated
Designation1 Type Configuration 6” BRZ – Bronze None Values2 Weight (kg/lbs.)
* BLK – Black
BKA – Bracket XBO-Bolt-On EC - Extension PLP – Platinum Plus 0.5 2/5
Aluminum XNM-Tenon Mount S - Single WHT – White
D180˚-Double GPT - Graphite 0.5 3/6
D90˚-Double SVG - Satin Verde Green 0.5 3/6
T90˚-Triple MSV - Metallic Silver 0.5 3/6
Q90˚-Quad 0.5 3/6
0.5 3/6
X4ISF-Internal Fitter D180˚-Double * 0.4 3/7
Q90˚-Quad 0.4 3/7
X5ISF-Internal Fitter D180˚-Double * 0.5 4/9
Q90˚-Quad 0.5 4/9
BKS – Bracket Steel XBO-Bolt-On WM-Wall Mount *- 2/5 POLES & BRACKETS
1/2
XBO-ADP-Pole 2H - 2 Hole *- 3/7
Retrofit Bracket 2H - 2 Hole 1/2
* EC6 - w/extension arm 0.3 1/2
3H - 3 Hole * None -
4H - 4 Hole -
FOOTNOTES: 2- The bracket EPA should be added to the fixture EPA when selecting the proper pole.
1- For mounting of fixtures with 3” reduced drilling pattern.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
63
AREA LIGHTING BRACKETS - BOLT-ON
BOLT-ON BRACKETS (with 5” Traditional Drill Pattern)
BO-Bolt-On Bracket BKA-HRBO-S-6-CLR: Upsweep Bracket - BKU-BO-S-19
BKA-BO-S-6 Hilton II (457mm)
BKA-BO-S-8 18"
BKA-BO-S-12
POLES & BRACKETS BKA BO RA 8 CLR: BKS-BO-WM-*-CLR:
Radius Arm for Wall Mount Plate
Challenger, for flat
Challenger II, surfaced
Patriot Small, Patriot, arm
and all Square and
Rectangular Fixtures 8" x 8"
(203mm x 203mm)
For Patriot Small order BKS-BO-PTS-WM-*-CLR
BKA-BO-ADJ-6-CLR: Adjustable 6" BKA-BO-EC-6-CLR: INTERNAL SLIP-FITTER 9-3/4”
Designed for direct mounting (152mm) Challenger & Patriot BKA-4ISF-D180-*-CLR (248mm)
Extension Arm BKA-4ISF-Q90-*-CLR
of fixture to face of bracket. For Challenger & Patriot Only BKA-5ISF-D180-*-CLR 17”
For Patriot Small order BKA-BO-PTS-EC-6-CLR BKA-5ISF-Q90-*-CLR (432mm)
Standard arms not required.
Not compatible with certain Fits 4" (102mm) or 5" (127mm) SQI
fixtures. Consult factory. square steel poles with wall thickness of
11ga. (0.120" - 3mm) or 7ga. (0.180" - 5mm).
For use with Square poles only.
BKS-BO-PA-40-CLR:
Parallel Arm
2" x 8" x 40"
(51mm x 203mm x 1016mm)
Note: Bolt-on parallel arms are designed for direct mounting
of fixture to face of bracket. Standard arms not required,
except for Hilton series.
LED ARRA
Funding Compliant Fixture Type © 2015
LSI INDUSTRIES INC.
Project Name
64 Catalog #
AREA LIGHTING BRACKETS - BOLT-ON
BRACKET ORDERING INFORMATION
BKATYPICAL ORDER EXAMPLE: BO S 8 BRZ
Bracket Bracket Bracket Length Bracket Finish Options EPA Values 2
Designation1 Type Configuration 6" BRZ – Bronze None –
BKA – Bracket Aluminum S – Single BLK – Black 0.4
HRBO – Hilton II D180° - Double * PLP – Platinum Plus 0.5
Q90° - Quad 6" WHT – White –
4ISF - Internal Fitter S – Single 8" GPT - Graphite –
5ISF - Internal Fitter 12" SVG - Satin Verde Green –
RA – Single 8" MSV - Metallic Silver 0.7
BO – Bolt-On ADJ – Adjustable 6" 0.1
EC - Extension 0.3
BKS – Bracket Steel BO – Bolt-On PTS EC - Extension * 0.3 POLES & BRACKETS
WM – Wall Mount ––
BKU – Upsweep Bracket PTS WM – Wall Mount 40" ––
Aluminum PA – Parallel Mount 19” 2.9
S – Single 0.4
ROUND POLE PLATE – For mounting fixtures to round poles1 Order Number RPPC - Challenger, RPP2 - ROUND
Patriot, and POLE PLATE
Description 162914BLK Patriot Small only
RPP2 – Round Pole Plate 141940CLR
RPPC – Round Pole Plate - Challenger, Patriot, & Patriot Small
FOOTNOTES:
1- For mounting of fixtures with 5” traditional drilling pattern.
2 - The bracket EPA should be added to the fixture EPA when selecting the proper pole. BKA HRBO and BKA BO are already included in the fixture EPA.
SHIPPING WEIGHTS - Area Lighting Brackets (Bolt-on and Tenon Mount)
Catalog Number Est. Weight (kg/lbs.) Catalog Number Est. Weight (kg/lbs.) Catalog Number Est. Weight (kg/lbs.)
BKS-BO-WM-* 2/5 BKA-BO-S-8 2/4 BKA-NM-T90/Q90 3/6
BKS-BO-PTS-WM-* 2/5 BKA-BO-S-12 2/5 BKS-RPT-TA-2.0+ 2/4
BKS-BO-PA-40 17/38 BKA-BO-EC-6 2/5 BKS-RPT-TA-2.5+ 4/8
BKS-NM-PA-40 19/41 BKA-BO-PTS-EC-6 2/5 BKS-RPT-TA-3.0+ 4/9
BKS-NM-RD-2.5/2 5/10 BKA-4ISF-D180 3/7 BKA-NM-ADJ+ 1/3
BKS-NM-RD-3.0/2 5/10 BKA-4ISF-Q90 3/7 BKA-BO-ADJ+ 2/5
BKS-NM-RD-3.5/2 5/10 BKA-5ISF-D180 4/9 BKA-RNM-TN120+ 4/8
BKU-BO-S-19 7/15 BKA-5ISF-Q90 4/9 BKA-BO-RA-8 3/7
BKA-HRBO-S-6 2/5 BKA-NM-S/D180 3/6 BKA-NM-MA-5 2/5
BKA-BO-S-6 1/3
+Aluminum bolt-on brackets and tenon mounts are bulk-packed.
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
65
AREA LIGHTING BRACKETS - TENON MOUNT
TENON BRACKETS (with 5”Traditional Drill Pattern)
BKA-NM-*-CLR: Tenon Mount Fitter BKA-RNM-TN120-CLR TENON MOUNT FITTER: BKA-NM-MA-5-CLR: Mast Arm Adaptor BKA-NM-ADJ-*-CLR: Tenon Mount Adjustable
For Radius Surface Brackets (Cannot be used w/ Hilton Series) Slip (Direct mount of fixture to bracket- discard arm.)
fits 2” pipe (2-3/8” (60mm) O.D.) Not compatible with certain fixtures.
Consult factory.
10-3/4” 11”
(273mm) (279mm) 9-3/4"
(248mm)
Single/D-180 D90/T90/Q90
(Drilled 2 Sides) (Drilled 4 Sides)
For flat surface brackets Drilled 3 sides at 120°
For Square fixtures, RPP2 or RPPC is required
P/N Description I.D. O.D. Fits
TENON 137096CLR BKS-NM-RD-2.5-CLR 3.068" (78mm) 3.5" (89mm) 2.875" (73mm)O.D.
REDUCERS* 137093CLR BKS-NM-RD-3.0-CLR 3.640" (92mm) 4.0" (107mm) 3.5" (89mm)O.D.
137090CLR BKS-NM-RD-3.5-CLR 4.140" (105mm) 4.5" (114mm) 4.0" (102mm)O.D.
BKS-NM-PA-40-CLR: Parallel Arm
POLES & BRACKETS 2" x 8" x 40" (51mm x 203mm x *Consult factory for other sizes.
1016mm) Tenon Adaptor
POLE TOP ADAPTOR
Note: Tenon mount parallel P/N Description I.D. O.D. Fits
arms are designed for direct mounting 107073CLR BKS-RPT-TA-2 2.469" (63mm) 2.875" (73mm) 2.375" (60mm) O.D.
of fixture to face of bracket. Standard arms 107074CLR BKS-RPT-TA-2.5 3.068" (78mm) 3.5" (89mm) 2.875" (73mm) O.D.
not required, except for Hilton Series. 107075CLR BKS-RPT-TA-3 3.548" (90mm) 4.0" (102mm) 3.5" (89mm) O.D.
BRACKET ORDERING INFORMATION
Bracket Bracket Bracket Length Bracket Finish Options EPA Values 4
Designation Type Configuration 40" BRZ – Bronze None 3.0
2.5/23 BLK – Black 0.1
BKS – Bracket Steel NM – Tenon Mount PA – Parallel Mount 3.0/23 PLP – Platinum Plus 0.1
3.5/23 WHT – White 0.1
RD – Reducers 2.0 GPT - Graphite 0.1
2.5 SVG - Satin Verde Green 0.1
– RPT-TA – Pole Top Adaptor 3.0 MSV - Metallic Silver 0.1
* 0.5
BKA – Bracket NM – Tenon Mount1 S – Single 0.5
Aluminum RNM - Round Tenon D180°– Double 5 0.5
Mount2 D90°– Double * 0.5
T90°– Triple 0.5
Q90°– Quad 0.3
ADJ – Adjustable 0.2
MA - Mast Arm Adaptor 0.2
TN120°– Triple
BKATYPICAL ORDER EXAMPLE: NM S * BLK NOTE: Standard slip-fitter fits 2-3/8" O.D. tenon (2.0 pipe tenon)
FOOTNOTES: 3- 2.5", 3.0", 3.5" I.D. pipe size is reduced to standard size 2-3/8" O.D.
1- For mounting of fixtures with 5” traditional drilling pattern. 4- The bracket EPA should be added to the fixture EPA when selecting the proper pole.
2- RNM requires RPP2 or RPPC.
SHIPPING WEIGHTS - Area Brackets
Catalog Number WEesitgihmta(tlebds.) EPA Catalog Number WEesitgihmta(tlebds.) EPA Catalog Number WEesitgihmta(tlebds.) EPA Catalog Number WEesitgihmta(tlebds.) EPA
BKA-BO-S-6+ 9 0.4 BKS-NM-ADJ++
BKS-BO-WM- * 5 - 4 0.4 BKA-5ISF-Q90 3 0.1
2.9 BKA-BO-S-8+ BKA-NM-S/D180 4 0.3 BKS-BO-ADJ++
BKS-BO-PA-40 38 3.0 4 0.4 5 0.1
0.1 BKA-BO-S-12+ 5 0.7 BKA-RNM-Q90++ 4 0.2
BKS-NM-PA-40 41 0.1 BKA-NM-T90/Q90 4 0.3 BKA-RNM-TN120++ 8
0.1 BKS-RPT-TA-2.0++
BKS-NM-RD-2.5/2 10 50.4 BKA-BO-EC-6 5 0.3 BKS-RPT-TA-2.5++ 4 0.1 0.2
0.4 BKA-RBO-WM++ 4 -
A R R ABKS-NM-RD-3.0/210 BKS-RPT-TA-3.0++ 8 0.1 BKA-BO-RA-8 7 0.7
10
BKS-NM-RD-3.5/2 BKA-4ISF-D180 7 0.3 9 0.1 BKA-NM-MA-5 5 0.2
LED BKA-HIBFOu-nSd-i6n+g Complia4nt
BKA-HRBO-S-8+ BKA-4ISF-Q90 7 0.3 + When ordered with fixture, bracket EPA included in fixture EPA.
5 BKA-5ISF-D180 9 0.4 ++Aluminum bolt-on brackets and tenon mounts are bulk-packed.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
66 Catalog #
FLOOD LIGHTING BRACKETS
TENON BRACKETS
BKS-PTB-2 17" BKS-PTB-3 17" BKS-PTB-3-30 BKS-PTB-4 17"
17" (432mm) 17" (432mm) 30" (762mm) 17" (432mm)
(432mm) (432mm) 30" (432mm)
(762mm)
2" 2" 2"
(51mm) (51mm) 2" (51mm)
(51mm)
PIPE PIPE PIPE
PIPE
BKS-PTB-12 BKS-PTB-13-30 BKS-PTB-14
48" 30" 24"
(1219mm) (762mm) (610mm)
STEEL POLE BOLT-ON BRACKETS1 POLES & BRACKETS
BKS-FBO-5 4-3/4" BKS-FBO-18 18-7/8" BKS-FBO-30 30"
(121mm) (479mm) (762mm)
BRACKET ORDERING INFORMATION
Bracket Bracket Bracket Bracket Finish Options EPA Values3
Designation Type Configuration BRZ – Bronze None 1.6
BLK – Black 2.1
TENON MOUNT PTB2 2 PLP – Platinum Plus 2.4
BKS – Bracket Steel 3 WHT – White 2.3
3-30 GPT - Graphite 1.8
4 SVG - Satin Verde Green 2.1
12 MSV - Metallic Silver 2.5
13-30
14
BOLT-ON FBO1 5 .1
BKS – Bracket Steel 18 .6
30 1.0
NOTE: Standard slip-fitter fits 2-3/8" O.D. tenon (2.0 pipe tenon)
BKS FBO 5TYPICAL ORDER EXAMPLE: BLK
3- The bracket EPA should be added to the fixture EPA when selecting the proper pole.
FOOTNOTES:
1- FBO brackets require pole preparation and must be ordered with “SF” or “DF” pole option. For
use with Steel Poles only. Consult factory for bolt-on flood brackets for aluminum poles.
2- PTB brackets slipfit 2-3/8" O.D. tenon. Order N tenon mount on poles.
SHIPPING WEIGHTS - Flood Brackets
Catalog Number Est. Weight (kg/lbs.) Catalog Number Est. Weight (kg/lbs.) Catalog Number Est. Weight (kg/lbs.)
BKS-PTB-2 11/24 BKS-PTB-12 9/28 BKS-FBO-5 2/5
BKS-PTB-13-30 15/38 BKS-FBO-18 6/14
BKS-PTB-3 15/32 BKS-PTB-14 17/37 BKS-FBO-30 13/29
BKS-PTB-3-30 13/29
BKS-PTB-4 18/40
ARRA LED
Funding Compliant Fixture Type © 2015
LSI INDUSTRIES INC.
Project Name 67
Catalog #
LSI ABOLITE® POLE BRACKETS Photograph may show
optional equipment.
• All LSI ABOLITE Designer Pole mounting hubs feature cast aluminum construction
for years of trouble-free service.
• All brackets are finished with gloss white powder finish but can be supplied in other
optional colors upon specification.
• All conduit supplied is rigid aluminum threaded for 3/4" N.P.T.
• Drawings are not shown to scale and are for general appearance only.
• Wet Location–All brackets are suitable for use in wet locations with RLM reflectors
(specify reflectors separately). Fixtures used in wet locations must be specified “WL”.
R 14"
(356mm)
3/4" NPT 47"
(1.2m)
POLES & BRACKETS
29-1/4"
(743mm)
3/4" 25-3/8" Single Reflector Pole Top Bracket.
(19mm) (645mm) Measures 19" high by 25-3/8" deep,
less reflector. Bracket slip fits over 4”
NPT 21-1/4" O.D. pole (see Pole Data page). The
(540mm) bracket features a gloss white
4-1/2" (114mm) powder finish.
For 4” pole order DPB4 1 GWT
Single Reflector Pole Top Bracket. Measures 40-1/8" high by
27" wide, less reflector. Bracket slip fits over 4” O.D. pole 19"
(see Pole Data page). The bracket features gloss white (483mm)
powder finish.
For 4” pole order SHCR4 1 GWT
6-7/8" (175mm) 3/4" N.P.T. 11-7/8"
(302mm)
16-3/4" R 9-1/8"
(425mm) (232mm)
4-1/2"
(114mm)
21"
(533mm)
Single Reflector Pole Top Bracket. Measures 15-1/2" high by 50-3/4"
18-1/4" wide, less reflector. Bracket slip fits over 4” O.D. pole (see (1.3m)
Pole Data page). The bracket features gloss white powder finish.
For 4” pole order CPC 1 GWT 19"
21" (483mm)
(533mm)
R 9-1/8" Single Reflector Pole Top 3/4" N.P.T.
(232mm) Bracket. Measures 36" high
24-1/4" by 18-1/4" wide, less 6-3/4" 42-1/2"
(616mm) reflector. Bracket slip fits (171mm) (1.1m)
over 4" O.D. pole (see Pole
37" Data page). The bracket Double Reflector Pole Top Bracket. Measures 19" high by 50-3/4" deep, less
(940mm) features gloss white reflectors. Bracket slip fits over 4" O.D. pole (see Pole Data page). The bracket
powder finish. features gloss white powder finish.
For 4” pole order For 4” pole order DPB4 2 GWT
CPCL 1 GWT
LED 4-1/2" ARRA
(114mm)
Funding Compliant
Project Name
Fixture Type © 2015
68 Catalog # LSI INDUSTRIES INC.
POLE BRACKETS AND ACCESSORIES
LSI GREENLEE LIFESTYLE BRACKETS LSI GREENLEE POLE BANNER BRACKETS -
BRACKETS - Brackets are extruded and cast aluminum assemblies or FOR USE WITH STEEL ROUND POLES
fabrications. All decorative elements are die cast or extruded aluminum. 1.50 Ø
FINISH - Finished with LSI’s DuraGrip® polyester powder coat finishing process. 18”, 24”, or 30”
The DuraGrip finish withstands extreme weather changes without cracking or
peeling, and is guaranteed for five full years. Standard colors include bronze,
black, platinum plus, white, satin verde green, metallic silver, and graphite.
LS BK CH STYPICAL ORDER EXAMPLE: BRZ
On any mounting style, order one bracket per pole. Choose the configuration
required and the correct brackets/arms will be supplied.
LSieferisetsy/lBerPacokleetBracketsMounting Style Configuration Pole Diameter Bracket Finish SITE
SPECIFIC
LM LS BK - CH - Classic Hook1 S - Single * BRZ – Bronze POLES & BRACKETS
D180˚ - Double BLK – Black
W - Wall Mount PLP – Platinum Plus
LS BK CH S BRZTYPICALLOifReDstEyRleEBXrAaMckPeLtE: WHT – White
SVG - Satin Verde Green
Orenquainryedmaonudntthinegcsotryrleec,tobrdraecrkSoeAnts-e/SabirdrmaecsAkrwemti2lpl ebrepsoulpeDSDT.p991Cl-0i80ehS˚˚0doi-˚-n.oT-gDsrlDoeeipoutlbuhelbeeleconf45ig--u54ra””tRRiooonuunndd GPT - Graphite
MSV - Metallic Silver
SLLLiiMeffereisLsettSsyy/lleBBeKrBPar-coaklceekteBtrackCeHtsM- ColuasnstiiUcnCgHCLolSa-omtkUy1plne3iverDWSsaC1-lo-8PSn0Woif˚nlieag-glullDerMTQSWDoa1u91to-i2b-80uoS0l˚0nWnei˚-˚tna--gQlTPllDuerMoaoiplduoelbeuDlneit*a4m54e--te54r”” Bracket Finish 4”.00 Ø OR 5”.00 Ø Pole
BRZ – Bronze
LSLMieferLiseStsyB/lBKerPPaSMceAkne-d- tLaSinifdetesMtAyorlemuPn2et nBdraanctkSDTDeM9t19-so008uS˚0˚ni--˚ntT-gDBrlDoeirpaoulcubeklbeelet 4 - 4” Round RRoouunnWPBddLLHPKT–––PBWllaahtciiknteum Plus
5 - 5” Round SGVPGTL--SeGStneragatmiptnhViteerdBeraGcrkeeent Finish
MSV - M1431326462880e"""""""tallicGBWBMPSSLLRVPSHiPKGlTZVvTe––-–--–rGSBPBMWrallraaaetohtciptnniaiknhtzleVuileticmeerSdPiellvuGesrreen
T120˚ - Triple Special EPA calculations are required on banner bracket applications, consult factory.
WQ9-0˚W-aQlluMadount4
TYPICAL ORDER EXAMPLE: BBKS 4R S 24 BLK
UCL - Universal Pole S - Single 4 - 4” Round Bracket Size Style Arm Length Finish
Clamp3 D180˚ - Double 5 - 5” Round S - Single 18 - 18" BRZ – Bronze
24 - 24" BLK – Black
Lifestyle FPOeOnTdNaOnTt EMSo: unt Brackets diameter Stem BpBoRlrZea.–ckBerot nFzienish BBKS - 4R - For 4" Dia. Arm 30 - 30" PLP – Platinum Plus
LSMerLieSsB/BKr21Pa--McPPkeoo- lltLeeifddeiisaatmmyleeetteePrreiinssdnreaoqntutrierMqeduo.iureUndtsieBnwrdaiecthskce3rti”prteiodnu.ceSdlipdfriitlslin4g”pattern.tenoLne(n46gN"t)hor BLK – Black Banner Round Pole D - D180 WHT – White
PLP – Platinum Plus Bracket 5R - For 5" Dia. SVG - Satin Verde Green
3- Pole diameter is required. 12" WHT – White (set of 2) Round Pole Double GPT - Graphite
4- Pole diameter not required in description. 18" SVG - Satin Verde Green Arm MSV - Metallic Silver
24" GPT - Graphite
GBC 4 5 BLKTYPICAL ORDER EXAMPLE: 30" MSV - Metallic Silver
36"
48"
FOOTNOTES:
1- Pole ddddiiiiaaaaDmmmmEeeeeamttttCeeeerrrrrOeoiniisssRlopdnrrteeAooerqqetTduulqryiieIurreVqfeeirrdduseEo..idtrGeemUiBdBnrsCAiednpb-eSwdsDoliaceEetwhrsccicopC3Skdrrtai”itpOoetysritnvlreiVioee.dlnciBuEc.acoRsoeSeadnliCt-pdeeofrviOditlerslripun4tgotb”ipodbmainaettmraea.reltntce.drhetePcpnoooolnrelae(D4t.4iiNavG5)meoBrebCtpeaorblsee.asceocvBPBWoeRLLHPKrvZTse––––rhBPBWllrfaaaoihtcFvtniiknsitzeneueim4tsw”hPloaus-npdie5c”e die cast construction with stainless steel fasteners. Base covers
2- Pole diameter straight round poles. Includes 4” round pole adaptor
3- Pole
4- Pole
GBC 4 5 BLKTYPICAL ORDER EXAMPLE: SVG - Satin Verde Green
GPT - Graphite
MSV - Metallic Silver
Style Pole Diameter Finish 9-3/4”
GBC - Decorative Base Cover 45 BRZ – Bronze (248mm)
BLK – Black 15"
PLP – Platinum Plus (381mm)
WHT – White
SVG - Satin Verde Green
GPT - Graphite
MSV - Metallic Silver
GBC 4 5
ARRA LED
Funding Compliant Fixture Type © 2015
LSI INDUSTRIES INC.
Project Name 69
Catalog #
WALL MOU NT LED CHALLENGER® WALL SCONCE (XCHWM3)
US patent 7828456, 8002428 and CAN 2736757 & 2736757 and MX patent 29631 and ISRL 49679 and AUS
2008312668 and US & Int'l. patents pending
SMARTTEC™ ENERGY SAVING FEATURES:
THERMAL CONTROL -LSI drivers feature integral sensor which reduces drive current, when
ambient temperatures exceed rated temperature.
OPTIONAL INTEGRAL MOTION SENSOR - Passive infrared motion sensor activates switching
of luminaire light levels. High level light is activated when passersby enter target zone and
increased to full bright in 1-2 seconds. Low light level (30% of maximum drive current)
is activated when target zone is absent of motion activity for 5 minutes and is gradually
ramped down (10 seconds) to low level. Sensor detection range 110° horizontal x 93°
vertical x 10 meters maximum distance.
EXPECTED LIFE - Minimum 60,000 hours to 100,000 hours depending upon the ambient
temperature of the installation location. See LSI web site for specific guidance.
DOE LIGHTING FACTS LEDS - Available with 28 or 48 select high-brightness LEDs in Cool White (5000K nominal) or
Department of Energy has verified representative product test Neutral White (4000K nominal) color temperature, 70 CRI (nominal).
data and results in accordance with its Lighting Facts Program.
Visit www.lightingfacts.com for specific catalog strings. OPTICS/DISTRIBUTIONS - Ultra-high efficiency reflectors provide three distributions. Choose
from Wide Throw (WT), Forward Throw (FT) or Wall Wash (WW).
LIGHT OUTPUT - XCHWM3
HOUSING - The aerodynamic aluminum housing is a rectangular shape. All mounting
Distribution/Lumens (Nominal) hardware is stainless steel or electro-zinc plated steel. Housing and optical unit are sealed
Milliamps # of LEDs Type FT Type WT Type WW Watts with extruded silicone gasket; supply conductors with molded EPDM bushing.
Neutral White Cool White 28 2876 2902 3032 34 OPTICAL UNIT - Clear tempered optical-grade flat glass lens sealed to the aluminum optic
450 mA 350 mA 450 mA 350 mA 55 housing creates an IP67 rated unit. Pressure stabilizing breather allows super-tight
48 4855 4931 5038 44 protection while preventing cycling from building up internal pressures and vacuums that
72 can stress optical unit seals.
28 3522 3542 3720
WALL MOUNTING - Galvanized-steel universal wall mounting plate easily mounts directly
48 5900 5972 6115 to 4” octagonal or square junction box. EPDM gasket is supplied to be installed between
mounting plate and junction box, sealing junction box from entrance of water. Universal
28 2787 2792 2898 34 plate permits fixture to be mounted in uplighting (indoor only) or downlighting position.
55
48 4553 4660 4580 44 POLE MOUNTING - XPMA (for square) or XPMAR (for round) allows mounting to poles in
72 single and D180 configurations. Use with 3” reduced drilling pattern.
28 3377 3369 3517
ELECTRICAL - Two-stage surge protection (including separate surge protection built into
48 5453 5562 5452 electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal
voltage power supply 120-277VAC (50/60Hz input) or 347-480VAC.
LED Chips are frequently updated therefore values may increase.
DRIVER - Available in 350mA and 450mA drive currents (Drive currents are factory
programmed). Components are fully encased in potting material for IP65 moisture
resistance. Driver complies with IEC and FCC standards. Driver can be easily accessed and
removed.
Also available in traditional light sources EMERGENCY OPTIONS - Integral emergency battery-back-up options are available. BB
option operates in 0°C to 60°C ambient temperature and CWBB operates in -20°C to 60°C
ambient temperature. When primary AC power failure occurs, both options operate 10
This product, or selected versions of this product, meet the standards LEDs for minimum of 90 minutes.
listed below. Please consult factory for your specific requirements.
OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F)
ARRA FINISH - Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process.
The DuraGrip finish withstands extreme weather changes without cracking or peeling.
wet location Funding Compliant
WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
IP65 PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT (in carton) - 30 lbs./13.6Kg
LISTING - ETL listed to ANSI/UL1598. UL8750 and other U.S. and international safety
standards. Suitable for wet locations in downlight position. For a list of the specific
products in this series that are DLC listed, please consult the LED Lighting section of our
website or the Design Lights website at www.designlights.org.
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
70 Catalog #
LED CHALLENGER® WALL SCONCE (XCHWM3) WALL MOU NT
LUMINAIRE ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XCHWM3 FT LED 48 450 CW UE WHT BB
Prefix Distribution Light Source # of LEDs Drive Current Color Temperature Input Voltage Finish Options
XCHWM3 - LED WT - Wide Throw LED 28 350 - 350mA CW - Cool White UE - Universal BLK - Black BB - Battery Back-up2
Challenger Wall FT- Forward Throw 48 450 - 450mA NW - Neutral White BRZ - Bronze CWBB - Cold Weather Battery Back-up2
Sconce WW - Wall Wash Voltage GPT - Graphite IMS - Integral Motion Sensor
(120-277) MSV - Metallic Silver PCI120 - 120V Button Type Photocell
PLP - Platinum Plus PCI208 - 208V Button Type Photocell
347-480 SVG - Satin Verde Green PCI240 - 240V Button Type Photocell
WHT - White PCI277 - 277V Button Type Photocell
1201 PCI347 - 347V Button Type Photocell
XPMA - Pole Mount Adaptor for use with
square pole (for single or D180 mounting
configuration only)3
XPMAR4 - Pole Mount Adaptor w/fixture
backplate for use with 4” O.D. round poles3
XPMAR5 - Pole Mount Adaptor w/fixture
backplate for use with 5” O.D. round poles3
TP - Tamper Proof4
NOTES: ACCESSORY ORDERING INFORMATION (Accessories are field installed)
1- On 28 LEDLuminaires, 120 Volt only is DLC qualified. Specify 120 in place of UE.
2- Available with UE voltage only Description Order Number
3- Designed with 3" reduced drilling pattern. For S or D180 mounting configuration only.
4- Tamper-proof Screwdriver must be ordered separately (See Accessory Ordering Information). XCHWM3 PLS - Polycarbonate Shield 172787
5- SW BLK not compatible with XPMA or XPMAR option. Available in black only. XCHWM3 SW BLK - Surface Wiring Box 173156BLK5
6- Fusing to be installed in a compatible junction box supplied by contractor. SCD - Tamper-proof Screwdriver
FK120 - Single Fusing 477974
FK277 - Single Fusing FK1206
DFK208, 240 - Double Fusing FK2776
DFK480 - Double Fusing DFK208,2406
FK347 - Single Fusing DFK4806
FK3476
DIMENSIONS 8-5/8"
(219 mm)
20"
(508 mm) 30° 3-7/8" 5 11/16"
3" (98 mm) (145 mm)
(76 mm) 11"
J-BOX CENTERLINE (279 mm) 7 3/4"
(197 mm)
13-1/2"
(343 mm) Universal Mounting Plate
8-5/8"
(219 mm)
J-BOX CENTERLINE 3-7/8"
(98 mm)
11"
(279 mm)
20" 15-3/8"
(508 mm) (390 mm)
Shown with IMS option LED
Project Name
Catalog # Fixture Type © 2015
LSI INDUSTRIES INC.
71
WALL MOU NT LED GREENBRIAR® WALL SCONCE (XGBWM3)
US patent 7828456, 8002428 and CAN 2736757 & 2736757 and MX patent 29631 and ISRL 49679 and AUS
2008312668 and US & Int'l. patents pending
SMARTTEC™ ENERGY SAVING FEATURES:
THERMAL CONTROL -LSI drivers feature integral sensor which reduces drive current, when
ambient temperatures exceed rated temperature.
OPTIONAL INTEGRAL MOTION SENSOR - Passive infrared motion sensor activates switching
of luminaire light levels. High level light is activated when passersby enter target zone and
increased to full bright in 1-2 seconds. Low light level (30% of maximum drive current)
is activated when target zone is absent of motion activity for 5 minutes and is gradually
ramped down (10 seconds) to low level. Sensor detection range 110° horizontal x 93°
vertical x 10 meters maximum distance.
Shown with optional decal striping EXPECTED LIFE - Minimum 60,000 hours to 100,000 hours depending upon the ambient
temperature of the installation location. See LSI web site for specific guidance.
DOE LIGHTING FACTS
Department of Energy has verified representative product test LEDS - Available with 28 or 48 select high-brightness LEDs in Cool White (5000K nominal) or
data and results in accordance with its Lighting Facts Program. Neutral White (4000K nominal) color temperature, 70 CRI (nominal).
Visit www.lightingfacts.com for specific catalog strings.
OPTICS/DISTRIBUTIONS - Ultra-high efficiency reflectors provide three distributions. Choose
LIGHT OUTPUT - XGBWM3 from Wide Throw (WT), Forward Throw (FT) or Wall Wash (WW).
Distribution/Lumens (Nominal) HOUSING - The aerodynamic aluminum housing is a rectangular shape. All mounting
Milliamps # of LEDs Type FT Type WT Type WW Watts hardware is stainless steel or electro-zinc plated steel. Housing and optical unit are sealed
with extruded silicone gasket; supply conductors with molded EPDM bushing.
Neutral White Cool White 28 2876 2902 3032 34
450 mA 350 mA 450 mA 350 mA 55 OPTICAL UNIT - Clear tempered optical-grade flat glass lens sealed to the aluminum optic
48 4855 4931 5038 housing creates an IP67 rated unit. Pressure stabilizing breather allows super-tight
protection while preventing cycling from building up internal pressures and vacuums that
28 3522 3542 3720 44 can stress optical unit seals.
72
48 5900 5972 6115 WALL MOUNTING - Galvanized-steel universal wall mounting plate easily mounts directly
to 4” octagonal or square junction box. EPDM gasket is supplied to be installed between
28 2787 2792 2898 34 mounting plate and junction box, sealing junction box from entrance of water. Universal
55 plate permits fixture to be mounted in uplighting (indoor only) or downlighting position.
48 4553 4660 4580 44
72 POLE MOUNTING - XPMA (for square) or XPMAR (for round) allows mounting to poles in
28 3377 3369 3517 single and D180 configurations. Use with 3” reduced drilling pattern.
48 5453 5562 5452 ELECTRICAL - Two-stage surge protection (including separate surge protection built into
electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal
LED Chips are frequently updated therefore values may increase. voltage power supply 120-277VAC (50/60Hz input) or 347-480VAC.
DRIVER - Available in 350mA and 450mA drive currents (Drive currents are factory
programmed). Components are fully encased in potting material for IP65 moisture
resistance. Driver complies with IEC and FCC standards. Driver can be easily accessed and
removed.
EMERGENCY OPTIONS - Integral emergency battery-back-up options are available. BB
option operates in 0°C to 60°C ambient temperature and CWBB operates in -20°C to 60°C
ambient temperature. When primary AC power failure occurs, both options operate 10
LEDs for minimum of 90 minutes.
OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F)
This product, or selected versions of this product, meet the FINISH - Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process.
standards listed below. Preleqausireecmoennstusl.t factory for your specific The DuraGrip finish withstands extreme weather changes without cracking or peeling.
DECAL STRIPING - Optional color-coordinated decals in 9 standard colors to accent the
fixture. Decals are guaranteed for five years against peeling, cracking, or fading.
wet location WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
A R R A IP65 PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data
Funding Compliant
SHIPPING WEIGHT (in carton) - 31 lbs./14Kg
LISTING - ETL listed to ANSI/UL 1598. UL8750 and other U.S. and international safety
standards. Suitable for wet locations in downlight position. For a list of the specific
products in this series that are DLC listed, please consult the LED Lighting section of our
website or the Design Lights website at www.designlights.org.
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
72 Catalog #
LED GREENBRIAR® WALL SCONCE (XGBWM3) CW UE WHT BB WALL MOU NT
LUMINAIRE ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XGBWM3 FT LED 48 450
Prefix Distribution Light Source # of LEDs Drive Current Color Temperature Input Voltage Finish Options
XGBWM3 - LED WT - Wide Throw LED 28 350 - 350mA CW - Cool White UE - Universal
FT- Forward Throw 48 450 - 450mA NW - Neutral White BLK - Black BB - Battery Back-up2
Greenbriar Wall WW - Wall Wash Voltage BRZ - Bronze CWBB - Cold Weather Battery Back-up2
Sconce (120-277) GPT - Graphite IMS - Integral Motion Sensor
MSV - Metallic Silver PCI120 - 120V Button Type Photocell
347-480 PLP - Platinum Plus PCI208 - 208V Button Type Photocell
SVG - Satin Verde Green PCI240 - 240V Button Type Photocell
1201 WHT - White PCI277 - 277V Button Type Photocell
PCI347 - 347V Button Type Photocell
XPMA - Pole Mount Adaptor for use with
Square Pole (for single or D180 mounting
configuration only)3
XPMAR4 - Pole Mount Adaptor w/fixture
backplate for use with 4” O.D. round poles3
XPMAR5 - Pole Mount Adaptor w/fixture
backplate for use with 5” O.D. round poles3
TP - Tamper Proof4
Color Decals
45 - Light Gold Metallic 55 - Black
20 - Charcoal Metallic 50 - White
94 - Blue Metallic 51 - Dark Red
21 - Tomato Red 59 - Dark Green
700 - Aztec Silver Metallic
NOTES: ACCESSORY ORDERING INFORMATION (Accessories are field installed)
1- On 28 LEDLuminaires, 120 Volt only is DLC qualified. Specify 120 in place of UE.
2- Available with UE voltage only Description Order Number
3- Designed with 3" reduced drilling pattern. For S or D180 mounting configuration only.
4- Tamper-proof Screwdriver must be ordered separately (See Accessory Ordering Information). XGBWM3 PLS - Polycarbonate Shield 172787
5- SW BLK not compatible with XPMA or XPMAR option. Available in black only. XGBWM3 SW BLK - Surface Wiring Box 173156BLK5
6- Fusing to be installed in a compatible junction box supplied by contractor. SCD - Tamper-proof Screwdriver
FK120 - Single Fusing 477974
FK277 - Single Fusing FK1206
DFK208, 240 - Double Fusing FK2776
DFK480 - Double Fusing DFK208,2406
FK347 - Single Fusing DFK4806
FK3476
DIMENSIONS 8-5/8" 3-7/8" 5 11/16"
(219 mm) (98 mm) (145 mm)
20-1/8"
(511 MM) 30° 11-3/8" 7 3/4"
3" J-BOX CENTERLINE (289 mm) (197 mm)
(76 mm)
13-1/2" Universal Mounting Plate
(343 MM)
3-7/8"
8-5/8" (98 mm)
(219 mm)
11-3/8"
30° (289 mm)
J-BOX CENTERLINE
20-1/8" 13-1/2"
(511 MM) (343 MM)
15-3/8"
(390 mm)
Shown with IMS option LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
73
WALL MOU NT LED PATRIOT® WALL SCONCE (XPWS3)
US patent 7828456, 8002428 and CAN 2736757 & 2736757 and MX patent 29631 and ISRL 49679 and AUS
2008312668 and US & Int'l. patents pending
SMARTTEC™ ENERGY SAVING FEATURES:
THERMAL CONTROL -LSI drivers feature integral sensor which reduces drive current, when
ambient temperatures exceed rated temperature
OPTIONAL INTEGRAL MOTION SENSOR - Passive infrared motion sensor activates switching
of luminaire light levels. High level light is activated when passersby enter target zone and
increased to full bright in 1-2 seconds. Low light level (30% of maximum drive current)
is activated when target zone is absent of motion activity for 5 minutes and is gradually
ramped down (10 seconds) to low level. Sensor detection range 110° horizontal x 93°
vertical x 10 meters maximum distance.
EXPECTED LIFE - Minimum 60,000 hours to 100,000 hours depending upon the ambient
temperature of the installation location. See LSI web site for specific guidance.
DOE LIGHTING FACTS LEDS - Available with 28 or 48 select high-brightness LEDs in Cool White (5000K nominal) or
Department of Energy has verified representative product test Neutral White (4000K nominal) color temperature, 70 CRI (nominal).
data and results in accordance with its Lighting Facts Program.
Visit www.lightingfacts.com for specific catalog strings. OPTICS/DISTRIBUTIONS - Ultra-high efficiency reflectors provide three distributions. Choose
from Wide Throw (WT), Forward Throw (FT) or Wall Wash (WW).
LIGHT OUTPUT - XPWS3
HOUSING - One-piece die-cast aluminum housing is smoothly contoured rectangular shape.
Distribution/Lumens (Nominal) Mounting hardware is stainless steel or electro-zinc plated steel. Housing and optical unit
Milliamps # of LEDs Type FT Type WT Type WW Watts are sealed with extruded silicone gasket; supply conductors with molded EPDM bushing.
Neutral White Cool White 28 3100 3000 3200 34 OPTICAL UNIT - Clear tempered optical-grade flat glass lens sealed to the aluminum optic
450 mA 350 mA 450 mA 350 mA 55 housing creates an IP65 rated unit. Pressure stabilizing breather allows super-tight
48 5100 5100 5200 protection while preventing cycling from building up internal pressures and vacuums that
can stress optical unit seals.
28 3700 3600 3800 44
72 WALL MOUNTING - Galvanized-steel universal wall mounting plate easily mounts directly
48 6200 6100 6300 to 4” octagonal or square junction box. EPDM gasket is supplied to be installed between
mounting plate and junction box, sealing junction box from entrance of water. Universal
28 2900 2900 3100 34 plate permits fixture to be mounted in uplighting (indoor only) or downlighting position.
55
48 4900 4800 4900 44 POLE MOUNTING - XPMA (for square) or XPMAR (for round) allows mounting to poles in
72 single and D180 configurations. Use with 3” reduced drilling pattern.
28 3500 3500 3700
ELECTRICAL - Two-stage surge protection (including separate surge protection built into
48 5800 5700 5800 electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal
voltage power supply 120-277VAC (50/60Hz input) or 347-480VAC.
LED Chips are frequently updated therefore values may increase.
DRIVER - Available in 350mA and 450mA drive currents (Drive currents are factory
Also available in traditional light sources programmed). Components are fully encased in potting material for IP65 moisture
resistance. Driver complies with IEC and FCC standards. Driver can be easily accessed and
removed.
EMERGENCY OPTIONS - Integral emergency battery-back-up options are available. BB
option operates in 0°C to 60°C ambient temperature and CWBB operates in -20°C to 60°C
ambient temperature. When primary AC power failure occurs, both options operate 10
LEDs for minimum of 90 minutes.
OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F)
This product, or selected versions of this product, meet the FINISH - Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process.
standards listed below. Preleqausireecmoennstusl.t factory for your specific The DuraGrip finish withstands extreme weather changes without cracking or peeling.
WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
ARRA wet location PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
(downlight only) photometric data.
Funding Compliant
IP65 SHIPPING WEIGHT (in carton) - 30 lbs./13.6Kg
LISTING - ETL listed to ANSI/UL1598, UL8750 and other U.S. and international safety
standards. Suitable for wet locations in downlight position. Optional Class 1 Division 2
(groups A, B, C &D) hazardous location rating is available (Select HL option). For a list
of the specific products in this series that are DLC listed, please consult the LED Lighting
section of our website or the Design Lights website at www.designlights.org.
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
74 Catalog #
LED PATRIOT® WALL SCONCE (XPWS3) WALL MOU NT
LUMINAIRE ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XPWS3 FT LED 48 450 CW UE WHT BB
Prefix Distribution Light Source # of LEDs Drive Current Color Temperature Input Voltage Finish Options
XPWS3 - 350 - 350mA CW - Cool White UE - Universal BLK - Black BB - Battery Back-up1
WT - Wide Throw LED 28 450 - 450mA NW - Neutral White BRZ - Bronze CWBB - Cold Weather Battery Back-up1
LED FT - Forward Throw 48 Voltage GPT - Graphite IMS - Integral Motion Sensor
Patriot WW - Wall Wash (120-277) MSV - Metalic Silver EMR2 - Two Emergency 12V Circuit Provisions
Wall PLP - Platinum Plus
Sconce 347-480 SVG - Satin Verde Green with (2) 35 Watt Halogen Lamps2
WHT - White PCI 120 - Button Type Photocell
PCI 208 - Button Type Photocell
PCI 240 - Button Type Photocell
PCI 277 - Button Type Photocell
PCI 347 - Button Type Photocell
HL - Class1, Division2, Hazardous Location Rating.
ETL listed to UL8443
XPMA - Pole Mounting Adaptor w/fixture
backplate for use with square poles4
XPMAR4 - Pole Mounting Adaptor w/fixture
backplate for use with 4” O.D. round poles4
XPMAR5 - Pole Mounting Adaptor w/fixture
backplate for use with 5” O.D. round poles4
ACCESSORY ORDERING INFORMATION (Accessories are field installed) Order Number
Description Order Number Description DFK208,2405
DFK4805
XPWS3 Polycarbonate Shield 244657 DFK208, 240 - Double Fusing FK3475
DFK480 - Double Fusing
XPWS3 SW BLK - Surface Wiring Box (Available in black only) 356915BLK FK347 - Single Fusing
FK120 - Single Fusing FK1205
FK277 - Single Fusing FK2775
FOOTNOTES:
1- Available with UE voltage only.
2 - Utilizes GZ4 sockets. 12 volt separate circuits required. Not available with battery back-up, photocell option, HL, XPMA or XPMAR options.
3 - Not available with battery backup, photocell or EMR2 option.
4 - Not available with EMR2 option. Designed with 3” reduced drilling pattern. For S or D180 mounting configuration only.
5 - Fusing to be installed in a compatible junction box supplied by contractor.
DIMENSIONS
4-5/8” 5-11/16”
(117mm) 8” (145mm)
(203mm) 7-3/4”
(197mm)
19-1/4” 11” Universal Mounting Plate
(489mm) (279mm)
4-5/8”
(117mm) 8”
(203mm)
19-1/4” 12-13/16”
(489mm) (325mm)
Shown with IMS Option
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
75
WALL MOU NT LED WALL SCONCE (PWM) US & Int'l. patents pending
DOE LIGHTING FACTS ENERGY SAVING CONTROL OPTIONS – DIM – 0-10 volt dimming enabled with controls by
Department of Energy has verified representative product test others.
data and results in accordance with its Lighting Facts Program.
Visit www.lightingfacts.com for specific catalog strings. EXPECTED LIFE - Minimum 60,000 hours to 100,000 hours depending upon the ambient
temperature of the installation location. See LSI web site for specific guidance.
LIGHT OUTPUT - PWM
LEDS - Available with select high-brightness LEDs in Cool White (5000K nominal) or Neutral
Distribution/Lumens (Nominal) White (4000K nominal) color temperature, 70 CRI (nominal).
Type S Watts DISTRIBUTION/PERFORMANCE - Type S (Standard Symmetric). Exceptional uniformity
creates bright environment at lower light levels.
Neutral White Cool White LW 1400 15
HOUSING - One-piece die-cast aluminum housing is smoothly contoured rectangular shape.
HO 5200 56 Mounting hardware is stainless steel or electro-zinc plated steel. Housing and optical unit
are sealed with extruded silicone gasket; supply conductors with molded EPDM bushing.
OPTICAL UNIT - Clear tempered optical-grade flat glass lens sealed to the aluminum optic
housing creates an IP65 rated unit. Pressure stabilizing breather allows super-tight
protection while preventing cycling from building up internal pressures and vacuums that
can stress optical unit seals.
WALL MOUNTING - Galvanized-steel universal wall mounting plate easily mounts directly
to 4” octagonal or square junction box. EPDM gasket is supplied to be installed between
mounting plate and junction box, sealing junction box from entrance of water. Universal
plate permits fixture to be mounted in uplighting (indoor only) or downlighting position.
POLE MOUNTING - XPMA (for square) or XPMAR (for round) allows mounting to poles in
single and D180 configurations. Use with 3” reduced drilling pattern.
ELECTRICAL - Two-stage surge protection (including separate surge protection built into
electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal
voltage power supply 120-277VAC (50/60Hz input) or 347-480VAC.
DRIVER - Available in Low Wattage (LW) and High Output (HO) drive currents (Drive currents
are factory programmed). Components are fully encased in potting material for moisture
resistance. Driver complies with FCC standards. Driver can be easily accessed and
removed. Optional 0-10V dimming available with controls by others.
OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F)
FINISH - Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process.
The DuraGrip finish withstands extreme weather changes without cracking or peeling.
WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT (in carton) - 27 lbs./12.2Kg
LISTING - UL listed to ANSI/UL1598, UL8750 and other U.S. and international safety
standards. Suitable for wet locations in downlight position. For a list of the specific
products in this series that are DLC listed, please consult the LED Lighting section of our
website or the Design Lights website at www.designlights.org.
LW 1300 15 This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
HO 4900 56
LED Chips are frequently updated therefore values may increase. ARRA IP65
Funding Compliant wet location
(downlight only)
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
76 Catalog #
LED WALL SCONCE (PWM) WALL MOU NT
LUMINAIRE ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: PWM S LED HO CW UE WHT PCI 120
Prefix Distribution Light Source Drive Current Color Temperature Input Voltage Finish Options
PWM - S - Standard LED LW - Low Watt CW - Cool White UE - Universal BLK - Black PCI 120 - Button Type Photocell
Symmetrical HO - High Output NW - Neutral White BRZ - Bronze PCI 208 - Button Type Photocell
LED Voltage GPT - Graphite PCI 240 - Button Type Photocell
Wall (120-277) MSV - Metallic Silver PCI 277 - Button Type Photocell
Sconce 347-480 PLP - Platinum Plus PCI 347 - Button Type Photocell
SVG - Satin Verde Green DIM - 0-10V Dimming (from external signal)
1201 WHT - White XPMA - Pole Mounting Adaptor w/fixture
backplate for use with square poles2
XPMAR4 - Pole Mounting Adaptor w/fixture
backplate for use with 4” O.D. round poles2
XPMAR5 - Pole Mounting Adaptor w/fixture
backplate for use with 5” O.D. round poles2
ACCESSORY ORDERING INFORMATION (Accessories are field installed) Order Number
Description Order Number Description
DFK208,2403
PWM Polycarbonate Shield 244657 DFK208, 240 - Double Fusing DFK4803
DFK480 - Double Fusing FK3473
PWM SW BLK - Surface Wiring Box (Available in black only) 356915BLK FK347 - Single Fusing
FK120 - Single Fusing FK1203
FK277 - Single Fusing FK2773
FOOTNOTES:
1- On Low Watt (LW) drive current, 120V only is DLC qualified. Specify 120 in place of UE.
2- Designed with 3” reduced drilling pattern. For S or D180 mounting configuration only.
3- Fusing to be installed in a compatible junction box supplied by contractor.
DIMENSIONS
4-5/8” 5-11/16”
(117mm) 8” (145mm)
(203mm) 7-3/4”
(197mm)
19-1/4” 11” Universal Mounting Plate
(489mm) (279mm)
4-5/8”
(117mm) 8”
(203mm)
19-1/4” 12-13/16”
(489mm) (325mm)
Shown with IMS Option
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
77
WALL MOU NT SMALL LED WALL PACK (SWS)
DIMENSIONS LEDs - Select high-brightness LEDs. Color temperature 5000K (CW), 4000K (NW) and
3000K (WW). CRI = 65 (All values nominal).
.47”
CONSTRUCTION - Die-cast aluminum housing with stainless steel hardware, tempered
6.30” 5.90” flat glass lens and silicon gaskets. Knock-out of top of housing for available photocell
accessory.
5.79” 3.53”
6.73” THERMAL MANAGEMENT - Driver and LED module are mounted directly to aluminum
housing to maximize heat dissipation.
DIMMING - 0-10 volt dimming standard.
INSTALLATION - Luminaire features a back plate design that can be easily mounted to any
vertical surface.
ELECTRICAL - Class 2 driver has universal voltage (120-277v, 50/60 Hz) input. Active
power factor correction (0.98 typical) and protection against over-voltage, over-
temperature, short-circuit conditions and lightning (ANSI/IEEE 62.41 Class A).
OPERATING TEMPERATURE - -35° to 40°C (-31° to 104°F)
EXPECTED LIFE - Minimum 50,000 hours.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
WARRANTY - Limited 5-year warranty.
LISTING - UL listed to U.S. and Canadian safety standards. For a list of the specific products
in this series that are DLC listed, please consult the LED Lighting section of our website or
the Design Lights website at www.designlights.org.
This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
wet location
LIGHT OUTPUT - SWS Watts LPW
14 92
Lumens
1322
LUMINAIRE ORDERING INFORMATION NW UE GBZ
SWS 2 LEDTYPICAL ORDER EXAMPLE:
Prefix Distribution Light Source Color Temperature Voltage Color
2 LED CW - Cool White GBZ - Grey Bronze
SWS - 14-watt NW - Neutral White UE -
LED Wall Pack WW - Warm White Universal
Electronic
(120-277V)
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description Order Number
120VAC Photocell SW PC1
208-277VAC Photocell SW PC2
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
78 Catalog #
MEDIUM LED WALL PACK (SWM) WALL MOU NT
LEDs - Select high-brightness LEDs. Color temperature 5000K (CW), 4000K (NW) and DIMENSIONS 8.07”
3000K (WW). CRI = 65 (All values nominal).
8.65” 1.48”
CONSTRUCTION - Die-cast aluminum housing with stainless steel hardware, tempered 5.24”
flat glass lens and silicon gaskets. Knock-out of top of housing for available photocell 10.61”
accessory. 11.80”
THERMAL MANAGEMENT - Driver and LED module are mounted directly to aluminum
housing to maximize heat dissipation.
DIMMING - 0-10 volt dimming standard.
INSTALLATION - Luminaire features a back plate design that can be easily mounted to any
vertical surface.
ELECTRICAL - Class 2 driver has universal voltage (120-277v, 50/60 Hz) input. Active
power factor correction (0.98 typical) and protection against over-voltage, over-
temperature, short-circuit conditions and lightning (ANSI/IEEE 62.41 Class A).
OPERATING TEMPERATURE - -35° to 40°C (-31° to 104°F)
EXPECTED LIFE - Minimum 50,000 hours.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
WARRANTY - Limited 5-year warranty.
LISTING - UL listed to U.S. and Canadian safety standards. For a list of the specific
products in this series that are DLC listed, please consult the LED Lighting section of our
website or the Design Lights website at www.designlights.org.
This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
wet location
LIGHT OUTPUT - SWM Watts LPW
42 98
Lumens
4080
LUMINAIRE ORDERING INFORMATION LED NW UE GBZ
SWM 2TYPICAL ORDER EXAMPLE:
Prefix Distribution Light Source Color Temperature Voltage Color
2 LED CW - Cool White GBZ - Grey Bronze
SWM - 42-watt NW - Neutral White UE -
LED Wall Pack WW - Warm White Universal
Electronic
(120-277V)
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description Order Number
120VAC Photocell SW PC1
208-277VAC Photocell SW PC2
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
79
WALL MOU NT LED WALL LIGHTS - AEROMAXTM (XAWSU/XAWMU)
US patent 7828456, 7952293, 8002428 and CAN 2693131 & 2701653 and US & Int'l. patents pending
SMARTTEC™ - LSI drivers feature integral sensor which reduces drive current, when ambient
temperatures exceed rated temperature.
ENERGY SAVING CONTROL OPTIONS – DIM – 0-10 volt dimming enabled with controls by
others. BLS – Bi-level switching responds to a 120-277V signal from separate controller or
sensor (by others), with low light level decreased to 30% maximum drive current.
OCCUPANCY SENSOR (IMS) - Optional internal passive infrared motion sensor activates
switching of luminaire light levels. High level light is activated and increased to full bright
in 1-2 seconds upon detection of motion. Low light level (30% maximum drive current)
is activated when target zone is absent of motion activity for ~ 2 minutes and ramps down
(10-15 sec.) to low level to allow eyes time to adjust. Sensor is located on the front of
optical assembly. Sensor optic has a detection cone of approximately 45°.
DARK-SKY FRIENDLY EXPECTED LIFE - Minimum 60,000 hours to 100,000 hours depending upon the ambient
temperature of the installation location. See LSI web site for specific guidance.
DOE LIGHTING FACTS LEDS - Select high-brightness LEDs in Cool White (5000K nominal) or Neutral White (4000K
Department of Energy has verified representative product test nominal) color temperature. 70 CRI (nominal).
data and results in accordance with its Lighting Facts Program.
Visit www.lightingfacts.com for specific catalog strings. DISTRIBUTION/PERFORMANCE - Types 3 and FT. Exceptional uniformity creates bright
environment at lower light levels.
LIGHT OUTPUT - XAWSU HOUSING - One-piece, die-formed aluminum. Weather-tight housing contains factory
prewired driver and field connections. Extruded one-piece EPDM gasketed wiring access
# of Lumens (Nominal) Watts door (with safety lanyard) is located underneath and utilizes tool-less thumbscrew fastener.
LEDS Type 3 Type FT (Nominal)
OPTICAL UNIT - Clear tempered optical grade flat glass lens sealed to aluminum optics
Neutral Cool SS 64 7000 6200 69 housing creates an IP67 rated, sealed optical unit (includes pressure-stabilizing breather).
White White 89 Optical unit is recessed into housing cavity and sealed to the housing with extruded one-
HO 64 8500 7650 69 piece EPDM gasket. Optical unit lanyard serves dual purposes of safety and provides
89 positive ground between unit and housing.
SS 64 6700 5700
MOUNTING - Tapered rear design allows fixtures to be easily mounted over a recessed junction
HO 64 7900 6700 box using a wall plate (supplied).
LIGHT OUTPUT - XAWMU ELECTRICAL - A terminal block for attachment of incoming primary wiring is supplied. Two-
stage surge protection (including separate surge protection built into electronic driver)
# of Lumens (Nominal) Watts meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power
LEDS Type 3 Type FT (Nominal) supply 120-277VAC (50/60Hz input), and 347-480 VAC. Optional twistlock photocell
receptacle is available. Photocell must be ordered separately.
Neutral Cool SS 128 13500 14100 139
White White 176
HO 128 16500 17300 139
176
SS 128 12400 13200
HO 128 15000 15800
LED Chips are frequently updated therefore values may increase.
DRIVER - Available in SS (Super Saver) and HO (High Output) drive currents (Drive currents
are factory programmed). Components are fully encased in potting material for IP65
moisture resistance. Driver complies with IEC and FCC standards. Driver and key electronic
components can easily be accessed.
OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F).
FINISH - Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process.
The DuraGrip finish withstands extreme weather changes without cracking or peeling.
WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT (in carton) - 31 lbs. / 14.1 Kg (small, fixture only). 39 lbs. / 17.7 Kg
(medium, fixture only). Add 5 lbs. / 12 Kg for wall plate for total shipment weight.
LISTING - ETL listed to U.S. and International safety standards. Suitable for wet locations.
This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
ARRA IP65
IP67
wet location Funding Compliant
LED Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Lighting Equipment - Luminaire Vibration 3G requirements.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
80 Catalog #
LED WALL LIGHTS - AEROMAXTM (XAWSU/XAWMU) WALL MOU NT
LUMINAIRE ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XAWSU FT LED 64 HO CW UE WHT PCR
Prefix Distribution Light # of Drive Color Input Voltage Finish Optional Controls Optional
Source LEDs Current Temperature Virtinet Wireless Network Sensor/Options
LED 64 SS - Super Saver (requires a Ventura controller/Malibu link) Sensor
XAWSU 3 - Type III CW - Cool White UE - Universal BLK - Black (blank) - None ES - External Sensor2
XAWMU FT - Forward HO -High Ouput NW - Neutral White Voltage BRZ - Bronze VCM - Standard (revenue grade) IMS - Integral Motion Sensor3
128 (120-277) GPT - Graphite VCMB - Basic
Throw MSV - Metallic Silver VCMH - Standard (Host) Options
VCMBH - Basic (Host) PCR - Photoelectric C ontrol
347-480 - Universal PLP - Platinum Plus DIM - 0-10 volt dimming
Voltage SVG - Satin Verde (required for satellite fixtures) Receptacle4
(347-480V) Green
WHT - White
Stand-Alone Control
(blank) - None
DIM - 0-10V Dimming
(from external signal)1
BLS Bi-level Switching
(from external 120-277V signal)1
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description Order Number Description Order Number
PC120 Photocell for use with PCR option (120V) 1225145 ROSB120 - WL Remote Box with 120V Occupancy Sensor C/F6
ROSB277 - WL Remote Box with 277V Occupancy Sensor C/F6
PC208-277 Photocell for use with PCR option (208V, 240V, 277V) 1225155 RPSB120 - Wet Location Remote Box with 120V External Photocell C/F6
RPSB208-277 - Wet Location Remote Box with 208-277V External Photocell C/F6
PC347 Photocell for use with PCR option (347V) 1595165
PC480 Photocell for use with PCR option (480V) 12251805
FOOTNOTES: 4- Photocell must be ordered separately. See Accessories.
1- IMS, DIM and BLS cannot be ordered together. 5 - Factory installed PCR option required.
2 - Do not specify for satellite units. 6 - Includes VCM. To be used in conjunction with VCM option in fixture. Consult factory.
3- Not compatible with Virtinet wireless systems, DIM or BLS.
DIMENSIONS (shown with VCM/VCMES option)
Medium
6-3/8" 18-3/8"
(161 mm) (465 mm)
6-3/8" 35-7/16" Bottom View
(161 mm) (900 mm)
Side View
18-3/8" Small 18-3/8"
(466 mm) (465 mm)
Front View 6-3/8"
(161 mm) Bottom View
26-1/2"
(674 mm)
Side View
Wall Bracket 8” (203mm)
6-1/2”
8”
(203mm) 6” (165mm)
11/16” 4-3/4” (152mm)
(18mm) (121mm)
Top View Front View
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
81
LED ALV MR16 WALL CYLINDERS (XALV WC) – LOW VOLTAGE
SHIELD/LENS ASSEMBLY – Shield is machined from premium alloys to match housing.
Downlight has a machined flat recessed lens. Uplight has a flush machined lens for
improved drainage. Uplight/Downlight combination has one of each. Lenses are tempered
glass.
SSUF – Short Uplight Shield with Flush Lens – Standard on Uplight.
SCDR – Collar Downlight Shield with Recessed lens – Standard on Downlight.
SCUD – Uplight/Downlight Shield Combination.
EXPECTED LIFE - Minimum 60,000 hours, depending upon the ambient operating
temperature of the installation location.
LED MODULE - LED MR16 Low Voltage, Bi-Pin module offers a choice of 3 color
temperatures; Neutral White (NW) - 4000K, Warm White (WW) - 3000K and Very Warm
(VW) - 2700K, with CRI>80.
ACCENT & FLOOD DIMENSIONS “HO” module features 4 “field selectable” light level equivalents of 50w, 35w, 20w & 10w,
via an easily accessible push button. Lamp is included with fixture.
XALV MR16 LED WCC HO 3.38” 1.15” “SS” module features 2 “field selectable” light level equivalents of 35w or 20w, via an
3.5” (88mm) (29mm) easily accessible High/Low mode switch.
(89mm) OPTICS / DISTRIBUTION - “HO” offers a choice of 3 beam patterns; Spot (SP) = 12°,
#8-32 HEX Medium Flood (MF) = 21°, Flood (FL) = 41° “SS” choices are Spot (SP) = 19°, Medium
SKT CAP Flood (NF) = 34°, Flood (FL) = 60°.
SCREW WIRING - Pre-wired with 250°C rated, 18 gauge, Teflon wire.
(2X)
8.76 (223)
4.72 0.38 (10) HOUSING - Aluminum housing is machined from premium 6061-T6 alum solid bar alloy.
Ø5.00 (120) Ø2.23 (Ø57) MOUNTING - Side mounted arm has a ½” NPSM threaded stainless steel connector for
(Ø127)
mounting to standard J-Box.
XALV MR16 LED WCD HO 3.38” 2.27” ELECTRICAL - 12V AC, 50/60 HZ input. Complies with UL8750 safety regulations and with
Ø5.00 (88mm) (58mm) ANSI/IEEE C62.41 Class A operation.
(Ø127)
#8-32 HEX DRIVER - Powered by a fully integrated, constant current, low voltage Class 2 LED driver,
SKT CAP with active power factor correction.
SCREW
(2X) 5.47 TRANSFORMER - Required and must be ordered separately. Compatible with low voltage
(139) magnetic or electronic transformers.
4.72 0.38 (10) OPERATING TEMPERATURE - -40°C to 55°C (-22°F to +104°F)
(120) FINISH - Standard finishes are BRS - Bronze Smooth, WHS - White Smooth and BKS -
3.5” Ø2.23 Black Smooth. MSV - Metallic Silver, SVG - Satin Verde Green and Graphite are available
(89mm) (Ø57) in textured finishes. All finishes are in a UV resistant, thermoset polyester powder coat
XALV MR16 LED WCU HO finish, which provides durable protection from environmental conditions, corrosion and the
3.5” Ø2.23 elements.
(89mm) #8-32 HEX (Ø57) 0.38 (10) WARRANTY - Limited 5-year warranty.
SKT CAP EXTRA VALUE FEATURES:
SCREW 4.04
(2X) (103)
4.79 3.38” 2.27” • Premium aluminum alloys protected by a chromate conversion process and polyester
(122) (88mm) (58mm) powder coat finish, provide XALV Series with incredible corrosion resistance, ensuring a
Ø5.00 long life and trouble free operation.
(Ø127)
• Precision O-ring sealing system between the lens and housing are high temperature
silicone or Viton fluoroelastomer material, prevents dust and water ingress.
This product, or selected versions of this product, meet the standards
listed below. Please consult factory for your specific requirements. • Posi-Seal provides reliable protection against water and dirt intrusion. No RTV silicone is
used to seal XALV fixtures.
ARRA IP66 • Available Spread Lenses, Color Filters, and Louvers expand performance.
• Waterproof wire connectors are provided with each low-voltage luminaire.
wet location Funding Compliant • ADA compliant.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
LED SHIPPING WEIGHT - 5 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
82 Catalog #
LED ALV MR16 WALL CYLINDERS (XALV WC) – LOW VOLTAGE
PRODUCT ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XALV WCC LED16 HO NW MF 12V SCUD BKS S75T
Prefix Type Light Color Beam Voltage Shield(s) Finish Mounting
Source Temp3 Angle4 Accessories
XALV WCU LED16 SS1 NW - Neutral SP - Spot Flood 12V - 12 volt SSUF - Short Uplight Shield BKS - Black Smooth NO - None
(LED ALV - (UpLight) LED16 HO2 White MF - Medium Flood - Flush Lens BRS - Bronze Smooth
Low Voltage) WW - Warm FL - Flood WHS - White Smooth Junction Box W/Xformer
WCD LED16 SS1 White SCDR -Collar Downlight Sheild SVG - Satin Verde S75T - Single Canopyr & J-Box
(Downlight) LED16 HO2 - Recessed Lens Green Textured with 75w 120:12v Stepdown
VW - Very Warm MSV - Metallic Silver
White SCUD - Uplight/Downlight Shield
WCC LED16 SS1 x 2 Lamps - Combination6 Textured Xformer
(Combo)7 LED16 HO2 x 2 Lamps
ACCESSORIES5
CFX16 - MR16 Color Filters
HL16 - MR16 Hexcell Louvers
LS16 - MR16 Linear Spread Lens
PS16 - MR16 Prismatic Spread Lens
ACCENT & FLOOD
NOTES:
1. 16 SS = MR16, 2-Position lamp featuring adjustable Hi/Lo switch, to replicate either 35w or 20w halogen light output levels.
2. 16 HO = MR16, 4-Position lamp featuring push button, to replicate four halogen light output levels (20w, 30w, 35w or 50w).
3. Color Temperatures; NW = 4,000k, WW = 3,000k, VW = 2,700k.
4. Beam Angle (SS): SP = 19 degree, MF = 34 degree, FL = 60 degree.
(HO): SP = 12 degree, MF = 21 degree, FL = 41 degree.
5. Only Single Filter/Louver Accessory Can Be Installed in Shield.
6. SCUD Shield Combines SSUF for Uplight & SCDR for Downlight LED Module Shielding.
7. WCC - Model supplied with identical LED Lamp Dist. For Upper & Lower Housings.
S75T Wall Mount with
LV Transformer
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
83
LED ALV PAR20 WALL CYLINDERS (XALV WC) – LINE VOLTAGE
ACCENT & FLOOD DIMENSIONS 3.91” 1.19” SHIELD/LENS ASSEMBLY – Shield is machined from premium alloys to match housing.
XALV WCC PAR20 LED (99mm) (30mm) Downlight has a machined flat recessed lens. Uplight has a flush machined lens for
improved drainage. Uplight/Downlight combination has one of each. Lenses are tempered
Ø5.00 5.86” glass.
(Ø127) (149mm) SSUF – Short Uplight Shield with Flush Lens – Standard on Uplight.
SCDR – Collar Downlight Shield with Recessed lens – Standard on Downlight.
#8-32 HEX 6.89” 0.38 (10) SCUD – Uplight/Downlight Shield Combination.
SKT CAP (175mm)
SCREW EXPECTED LIFE - Minimum 60,000 hours, depending upon the ambient operating
(2X) Ø2.73” temperature of the installation location.
(69mm)
3.5” LED MODULE - LED PAR20 Line Voltage, module offers a choice of 3 color temperatures;
(89mm) 3.91” (625.5m5m”) Neutral White (NW) - 4000K, Warm White (WW) - 3000K and Very Warm (VW) - 2700K,
(99mm) with CRI>80. The lamp features 4 “field selectable” light levels of 100%, 80%, 55% &
XALV WCD PAR20 LED 18%, via an easily accessible push button.
Ø(Ø51.2070) (310.1m9m”)
OPTICS / DISTRIBUTION - Choice of 4 beam patterns; Spot (SP) = 15°, Narrow Flood (NF)
7.64” = 23°, Flood (FL) = 35° and Wide Flood (WF) = 51°.
#8-32 HEX (194mm)
SKT CAP 6.89” 0.38 (10) WIRING - Pre-wired with 200°C rated wire.
SCREW (175mm) (Ø629.m7m3”) HOUSING - Aluminum housing is CNC machined from premium 6061-T6 alum solid bar
(2X)
alloy.
(839.m5”m) MOUNTING - Side mounted arm has a ½” NPSM threaded stainless steel connector for
XALV MR16 LED WCU HO (Ø629.m7m3”) attachment to mounting devices.
ELECTRICAL - 120 VAC, 50/60 HZ input. Complies with UL8750 safety regulations and with
(ØØ#SS518.KC20-RT730E)2CWAHPEX(166(.8165m41.9”m8m6)”m) 0.38 (10)
(2X) 1.19” ANSI/IEEE C62.41 Class A operation.
(30mm) DRIVER - Powered by a fully integrated, constant current, line voltage Class 2 LED driver,
(839.m5”m) (939.9m1m”) (625.5m5m”)
with active power factor correction.
OPERATING TEMPERATURE - -40°C to 55°C (-22°F to +104°F)
FINISH - Standard finishes are BRS - Bronze Smooth, WHS – White Smooth and BKS –
Black Smooth. MSV – Metallic Silver, SVG – Satin Verde Green and Graphite textured
finishes. All finishes are in a UV resistant, thermoset polyester powder coat finish, which
provides durable protection from environmental conditions, corrosion and the elements.
WARRANTY - Limited 5-year warranty.
EXTRA VALUE FEATURES:
• Premium aluminum alloys protected by a chromate conversion process and polyester
powder coat finish, provide XALV Series with incredible corrosion resistance, ensuring a
long life and trouble free operation.
• Precision O-ring sealing system between the lens and housing are high temperature
silicone or Viton fluoroelastomer material, prevents dust and water ingress.
• Posi-Seal provides reliable protection against water and dirt intrusion. No RTV silicone is
used to seal XALV fixtures.
• Available Spread Lenses, Color Filters, and Louvers expand performance.
• ADA compliant.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT - 5 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
This product, or selected versions of this product, meet the standards
listed below. Please consult factory for your specific requirements.
ARRA IP66
LED wet location Funding Compliant
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
84 Catalog #
LED ALV PAR20 WALL CYLINDERS (XALV WC) – LINE VOLTAGE WM
PRODUCT ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XALV WCC LED20 VW FL 120V SCUD BKS J4R
Prefix Type Light Color Beam Voltage Shield(s) Finish Mounting
Source Temp2 Angle4 Accessories
LED201
XALV WCU NW - Neutral SP - Spot Flood 120V SSUF - Short Uplight Shield BKS - Black Smooth NO - None
(LED ALV - (UpLight) LED201 White NF - Narrow Flood - Flush Lens BRS - Bronze Smooth
Line Voltage) WW - Warm FL - Flood WHS - White Smooth Junction Boxes
WCD White WF - Wide Flood SCDR -Collar Downlight Sheild SVG - Satin Verde J4R WM - Junction Box
(Downlight) VW - Very Warm - Recessed Lens Green Textured
White MSV - Metallic Silver J4R WM SCE - Junction Box Side
WCC LED201,2 SCUD - Uplight/Downlight Shield Textured Conduit Entry
(Combo - Combination6
Up/Down)2 ACCESSORIES5
CFX20 - PAR20 Color Filters
HL20 - PAR20 Hexcell Louvers
LS20 - PAR20 Linear Spread Lenses
PS20 - PAR20 Prismatic Spread Lenses
NOTES: ACCENT & FLOOD
1. PAR20 - Lamp provides choice of 4 field selectable light levels: 100%, 80%, 55% & 18%.
2. WCC - Model supplied with identical LED Lamp Dist. For Upper & Lower Housings.
3. Color Temperatures; NW = 4,000K, WW = 3,000K, VW = 2,700K.
4. Beam Angle: SP = 15 degrees, NF = 23 degrees, FL = 35 degrees, WF = 51 degrees.
5. Only Single Filter/Louver Accessory Can Be Installed in Shield
6. SCUD Shield Combines SSUF for Uplight & SCDR for Downlight LED Module Shielding
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
85
LED ALV MR16 SIGN LIGHTS (XALV SL) – LOW VOLTAGE
SHIELD/LENS ASSEMBLY – Available in six combinations to maximize design flexibility.
Shield is machined from premium alloys to match housing. Lenses are tempered glass.
Select R – Recessed flat lens or F – Flush machined lens (for improved drainage).
SSDR – Short Shield – Recessed Lens; SSUF – Short Shield – Flush Lens;
SCDR – Collar Shield – Recessed lens and Aqueducts; SCUA – Collar Shield – Flush
Lens and Aqueducts; S3DR – 30° Cutoff Shield – Recessed Lens; S3UF – 30° Cutoff
Shield – Flush Lens
EXPECTED LIFE - Minimum 60,000 hours, depending upon the ambient operating
temperature of the installation location.
LED MODULE - LED MR16 Low Voltage, Bi-Pin module offers a choice of 3 color
temperatures; Neutral White (NW) - 4000K, Warm White (WW) - 3000K and Very Warm
(VW) - 2700K, with CRI>80.
ACCENT & FLOOD DIMENSIONS “HO” module features 4 “field selectable” light level equivalents of 50w, 35w, 20w & 10w,
via an easily accessible push button.
XALV SL LED MR16 HO SCDR “SS” module features 2 “field selectable” light level equivalents of 35w or 20w, via an
easily accessible High/Low mode switch.
5.26” 2.23” (57mm) OPTICS / DISTRIBUTION - “HO” offers a choice of 3 beam patterns; Spot (SP) = 12°,
(134mm) Medium Flood (MF) = 21°, Flood (FL) = 41° “SS” choices are Spot (SP) = 19°, Medium
Flood (MF) = 34°, Flood (FL) = 60°.
2” (51mm) WIRING - Pre-wired with 250°C rated, 18 gauge, Teflon wire. Extended leads provided (SL).
HOUSING - Aluminum housing is CNC machined from premium 6061-T6 alum solid bar
alloy.
XALV SL LED MR16 SS SCDR MOUNTING - Rear mounted arm has a ½” NPSM threaded stainless steel knuckle for
4.58” mounting to standard J-Box or mounts.
(116mm) 2.23” (57mm) ELECTRICAL - 12V AC, 50/60 HZ input. Complies with UL8750 safety regulations and with
ANSI/IEEE C62.41 Class A operation.
2” (51mm) DRIVER - Powered by a fully integrated, constant current, low voltage Class 2 LED driver,
with active power factor correction.
TRANSFORMER - Required and must be ordered separately. Compatible with low voltage
magnetic or electronic transformers.
OPERATING TEMPERATURE - -40°C to 55°C (-22°F to +104°F)
FINISH - Standard finishes are BRS - Bronze Smooth, WHS - White Smooth and BKS - Black
Smooth. MSV - Metallic Silver, SVG - Satin Verde Green and Graphite are textured finishes.
All finishes are in a UV resistant, thermoset polyester powder coat finish, which provides
durable protection from environmental conditions, corrosion and the elements.
WARRANTY - Limited 5-year warranty.
This product, or selected versions of this product, meet the standards EXTRA VALUE FEATURES:
listed below. Please consult factory for your specific requirements. • Premium aluminum alloys protected by a chromate conversion process and polyester
powder coat finish, provide XALV Series with incredible corrosion resistance, ensuring a
long life and trouble free operation.
IP66
ARRA • Precision O-ring sealing system between the lens and housing are high temperature
silicone or Viton fluoroelastomer material, prevents dust and water ingress.
wet location Funding Compliant
• Posi-Seal provides reliable protection against water and dirt intrusion. No RTV silicone is
used to seal XALV fixtures.
• Available Spread Lenses, Color Filters, and Louvers expand performance.
• Waterproof wire connectors are provided with each low-voltage luminaire.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT - 3 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
86 Catalog #
LED ALV MR16 SIGN LIGHTS (XALV SL) – LOW VOLTAGE
PRODUCT ORDERING INFORMATION
XALVTYPICAL ORDER EXAMPLE: SL LED16 HO NW MF 12V S3DR SVG CH MS24 SLB90 S75T
Prefix Light Drive Color Beam Voltage Shield(s) Finish Mounting
Type Source Current Temp4 Angle5 Accessories
XALV SL - Sign1 LED16 SS2 NW - Neutral SP - Spot Flood 12V - 12 volt9 SSDR - Short Shield - BKS - Black Smooth NO - None
(LED ALV - Light HO3 White MF - Medium Flood Recessed Lens BRS - Bronze Smooth
Low Voltage) WW - Warm FL - Flood SSUF - Short Shield - WHS - White Smooth Mounting Stems
White Flush Lens SVG - Satin Verde MSXX - Straight Stem (Specify Length)
VW - Very Warm SCDR - Collar Shield -
White Recessed Lens Aqueducts Green Textured 18", 24", 30", & 36"
SCUA - Collar Shield - MSV - Metallic Silver Mounting Brackets
Flush Lens Aqueducts A90 - 90° Arm Bracket
S3DR - 30° Cutoff Shield - Textured CH - Classic Hook Bracket
Recessed Lens GPT - Graphite TMA - Twin Mount Adaptor7
SLB90 - Single 90° Sign Light Bracket
Textured
S3UF - 30° Cutoff Shield - TLB90 - Twin 90° Sign Light Bracket7
Junction Box W/Xformer
Flush Lens S75T - Single Canopyr & J-Box
with 75w 120:12v Transformer ACCENT & FLOOD
ACCESSORIES6
CFX16 - MR16 Color Filters8
HL16 - MR16 Hexcell Louvers
LS16 - MR16 Linear Spread Lenses
PS16 - MR16 Prismatic Spread Lenses
CC250 - 250' Spool of 12-2 stranded
Low Energy - Underground Cable
NOTES:
1. SL - Sign Lights. Sign lights have extended leads for use with mounting stems & brackets.
2. 16 SS = MR16, 2-Position lamp featuring adjustable Hi/Lo switch, to replicate either 35w or 20w halogen light output levels.
3. 16 HO = MR16, 4-Position lamp featuring adjustable button, to replicate four Halogen light output levels (10w, 20w, 35w or 50w).
4. Color Temperatures; NW = 4,000K, WW = 3,000K, VW = 2,700K.
5. Beam Angle (SS): SP = 19 degree, MF = 34 degree, FL = 60 degree.
(HO): SP = 12 degree, MF = 21 degree, FL = 41 degree.
6. Only Single Accessory Can Be Installed in Shield
7. TLB90 & TMA twin mounts supplied with 2ea identical XALV SL luminaires.
8. Color Filters - Replace "X" with required filter color - R-Red, G-Green, B-Blue, Y-Yellow.
9. Transformer is required.
A90 - 90° Arm S75T Wall Mount with CH - Classic Hook MS - Straight Stem
LV Transformer
TMA - Twin SLB90 – Single 90º TLB90 – Twin 90º
Mount Adaptor Sign Light Fitting Sign Light Fitting
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
87
LED ALV PAR20 SIGN LIGHTS (XALV SL) – LINE VOLTAGE
ACCENT & FLOOD DIMENSIONS SHIELD/LENS ASSEMBLY – Available in six combinations to maximize design flexibility.
Shield is machined from premium alloys to match housing. Lenses are tempered glass.
XALV SL PAR20 LED SCDR Select R – Recessed flat lens or F – Flush machined lens (for improved drainage).
SSDR – Short Shield – Recessed Lens; SSUF – Short Shield – Flush Lens;
7.41” (188mm) 2.72” (69mm) SCDR – Collar Shield – Recessed lens and Aqueducts; SCUA – Collar Shield – Flush
Lens and Aqueducts; S3DR – 30° Cutoff Shield – Recessed Lens; S3UF – 30° Cutoff
2” (51mm) Shield – Flush Lens.
XALV SL PAR20 LED S3DR 2.72” (69mm) EXPECTED LIFE - Minimum 60,000 hours, depending upon the ambient operating
7.92” (201mm) temperature of the installation location.
2” (51mm) LED MODULE - LED PAR20 Line Voltage, module offers a choice of 3 color temperatures;
Neutral White (NW) - 4000K, Warm White (WW) - 3000K and Very Warm (VW) - 2700K,
XALV SL PAR20 LED SSDR with CRI>80. The lamp features 4 “field selectable” light levels of 100%, 80%, 55% &
6.37” (162mm) 2.72” (69mm) 18%, via an easily accessible push button.
2” (51mm) OPTICS / DISTRIBUTION - Choice of 4 beam patterns; Spot (SP) = 15°, Narrow Flood (NF)
= 23°, Flood (FL) = 35° and Wide Flood (WF) = 51°. XALV Sign Lights are easy to adjust,
aim and lock in place.
WIRING - Pre-wired with 200°C rated Tefzel wire. Extended leads are provided (SL).
HOUSING - Aluminum housing is CNC machined from premium 6061-T6 alum solid bar
alloy.
MOUNTING - RM – Rear Mount arms have a ½” NPSM threaded stainless steel connector
for attachment to J-box or mounts.
ELECTRICAL - 120 VAC, 50/60 HZ input. Complies with UL8750 safety regulations and with
ANSI/IEEE C62.41 Class A operation.
DRIVER - Powered by a fully integrated, constant current, line voltage Class 2 LED driver,
with active power factor correction.
OPERATING TEMPERATURE - -40°C to 55°C (-40°F to +131°F)
FINISH - Standard finishes are BRS - Bronze Smooth, WHS – White Smooth and BKS –
Black Smooth finishes. MSV – Metallic Silver, SVG – Satin Verde Green and Graphite are
textured finishes. All finishes are in a UV resistant, thermoset polyester powder coat finish,
which provides durable protection from environmental conditions, corrosion and the
elements.
WARRANTY - Limited 5-year warranty.
EXTRA VALUE FEATURES:
• Premium aluminum alloys protected by a chromate conversion process and polyester
powder coat finish, provide XALV Series with incredible corrosion resistance, ensuring a
long life and trouble free operation.
• Precision O-ring sealing system between the lens and housing are high temperature
silicone or Viton fluoroelastomer material, prevents dust and water ingress.
• Posi-Seal provides reliable protection against water and dirt intrusion. No RTV silicone is
used to seal ALV fixtures.
• Available Spread Lenses, Color Filters, and Louvers expand performance.
• Shield/Lens combinations give designers unequalled choice and flexibility.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT - 5 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
LED ARRA IP66
wet location Funding Compliant
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
88 Catalog #
LED ALV PAR20 SIGN LIGHTS (XALV SL) – LINE VOLTAGE
PRODUCT ORDERING INFORMATION
XALVTYPICAL ORDER EXAMPLE: SL LED20 NW FL 120V S3UF MSV MS24 A90 TMA J4R WM
Prefix Type Light Color Beam Voltage Shield(s) Finish Mounting
XALV SL - Sign1 Source Temp3 Angle4 120V SSDR - Short Shield - Accessories
LED20 2
(LED ALV - Light NW - Neutral SP - Spot Flood Recessed Lens BKS - Black Smooth NO - None
Line Voltage) White NF - Narrow Flood SSUF - Short Shield - BRS - Bronze Smooth
WHS - White Smooth Mounting Stems
WW - Warm FL - Flood Flush Lens SVG - Satin Verde MSXX - Straight Stem (Specify Length)
White WF - Wide Flood SCDR - Collar Shield - Green Textured
VW - Very Warm Recessed Lens Aqueducts 6", 12", 18", 24", 30", & 36"
White SCUA - Collar Shield - MSV - Metallic Silver Mounting Brackets
Textured
Flush Lens Aqueducts GPT - Graphite A90 - 90° Arm Bracket
S3DR - 30° Cutoff Shield - CH - Classic Hook Bracket
Textured TMA - Twin Mount Adaptor6
Recessed Lens
S3UF - 30° Cutoff Shield - SLB90 - Single 90° Sign Light Bracket
TLB90 - Twin 90° Sign Light Bracket6
Flush Lens Junction Boxes
J4R SC - Junction Box ACCENT & FLOOD
J4R SCE - Junction Box Side
Conduit Entry
ACCESSORIES5
CFX20 - PAR20 Color Filters7
HL20 - PAR20 Hexcell Louvers
LS20 - PAR20 Linear Spread Lenses
PS20 - PAR20 Prismatic Spread Lenses
NOTES:
1. SL - Sign Lights. Sign lights have extended leads for use with mounting stems & brackets.
2. PAR20 - Lamp provides choice of 4 field selectable light levels: 100%, 80%, 55% & 18%.
3. Color Temperatures; NW = 4,000K, WW = 3,000K, VW = 2,700K.
4. Beam Angle: SP = 15 degrees, NF = 23 degrees, FL = 35 degrees, WF = 51 degrees.
5. Only Single Filter/Louver Accessory Can Be Installed in Shield
6. TLB90 & TMA twin mounts supplied with 2ea identical XALV SL luminaires.
7. Color Filters - Replace "X" with required filter color - R-Red, G-Green, B-Blue, Y-Yellow.
A90 - 90° Arm CH - Classic Hook MS - Straight Stem
TMA - Twin SLB90 – Single 90º TLB90 – Twin 90º JAR SC
Mount Adaptor Sign Light Fitting Sign Light Fitting Junction Box
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
89
LED ALV MR16 ACCENT LIGHTS (XALV AL) – LOW VOLTAGE
SHIELD/LENS ASSEMBLY – Available in six combinations to maximize design flexibility.
Shield is machined from premium alloys to match housing. Lenses are tempered glass.
Select R – Recessed flat lens or F – Flush machined lens (for improved drainage).
SSDR – Short Shield – Recessed Lens; SSUF – Short Shield – Flush Lens;
SCDR – Collar Shield – Recessed lens and Aqueducts; SCUA – Collar Shield – Flush
Lens and Aqueducts; S3DR – 30° Cutoff Shield – Recessed Lens; S3UF – 30° Cutoff
Shield – Flush Lens
EXPECTED LIFE - Minimum 60,000 hours, depending upon the ambient operating
temperature of the installation location.
LED MODULE - LED MR16 Low Voltage, Bi-Pin module offers a choice of 3 color
temperatures; Neutral White (NW) - 4000K, Warm White (WW) - 3000K and Very Warm
(VW) - 2700K, with CRI>80.
ACCENT & FLOOD DIMENSIONS “HO” module features 4 “field selectable” light level equivalents of 50w, 35w, 20w & 10w,
via an easily accessible push button.
XALV AL LED MR16 HO SCDR “SS” module features 2 “field selectable” light level equivalents of 35w or 20w, via an
easily accessible High/Low mode switch.
5.26” 2.23” (57mm) OPTICS / DISTRIBUTION - “HO” offers a choice of 3 beam patterns; Spot (SP) = 12°,
(134mm) Medium Flood (MF) = 21°, Flood (FL) = 41° “SS” choices are Spot (SP) = 19°, Medium
Flood (MF) = 34°, Flood (FL) = 60°.
2” (51mm) WIRING - Pre-wired with 250°C rated, 18 gauge, Teflon wire.
HOUSING - Aluminum housing is CNC machined from premium 6061-T6 alum solid bar
alloy.
XALV AL LED MR16 SS SCDR MOUNTING - Rear mounted arm has a ½” NPSM threaded stainless steel knuckle for
4.58” mounting to standard J-Box or mounts.
(116mm) 2.23” (57mm) ELECTRICAL - 12V AC, 50/60 HZ input. Complies with UL8750 safety regulations and with
ANSI/IEEE C62.41 Class A operation.
2” (51mm) DRIVER - Powered by a fully integrated, constant current, low voltage Class 2 LED driver,
with active power factor correction.
TRANSFORMER - Required and must be ordered separately. Compatible with low voltage
magnetic or electronic transformers.
OPERATING TEMPERATURE - -40°C to 55°C (-22°F to +131°F)
FINISH - Standard finishes are BRS - Bronze Smooth, WHS – White Smooth and BKS –
Black Smooth. MSV – Metallic Silver, SVG – Satin Verde Green and GPT – Graphite are
textured finishes. All finishes are in a UV resistant, thermoset polyester powder coat
finish, which provides durable protection from environmental conditions, corrosion and the
elements.
WARRANTY - Limited 5-year warranty.
EXTRA VALUE FEATURES:
• Premium aluminum alloys protected by a chromate conversion process and polyester
powder coat finish, provide XALV Series with incredible corrosion resistance, ensuring a
long life and trouble free operation.
• Precision O-ring sealing system between the lens and housing are high temperature
silicone or Viton fluoroelastomer material, prevents dust and water ingress.
This product, or selected versions of this product, meet the standards • Posi-Seal provides reliable protection against water and dirt intrusion. No RTV silicone is
listed below. Please consult factory for your specific requirements. used to seal XALV fixtures.
• Shield/Lens combinations give designers unequaled choice and flexibility.
ARRA IP66 • Available Spread Lenses, Color Filters, and Louvers expand performance.
• Waterproof wire connectors are provided with each low-voltage luminaire.
wet location Funding Compliant
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
LED SHIPPING WEIGHT - 3 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
90 Catalog #
LED ALV MR16 ACCENT LIGHTS (XALV AL) – LOW VOLTAGE MTP12
PRODUCT ORDERING INFORMATION
XALVTYPICAL ORDER EXAMPLE: AL LED16 HO WW MF 12V S3DR SVG
Prefix Type Light Drive Color Beam Voltage Shield(s) Finish Mounting
Source Current Temp3 Angle4 SSDR - Short Shield - Accessories
LED16
XALV AL - Accent SS1 NW - Neutral SP - Spot Flood 12V - 12 volt Recessed Lens BKS - Black Smooth NO - None
(LED ALV - Light HO2 White MF - Medium Flood SSUF - Short Shield - BRS - Bronze Smooth
Low Voltage) WW - Warm FL - Flood WHS - White Smooth Mounting Spikes
White Flush Lens SVG - Satin Verde SPP - ABS Spike for Low Voltage fixtures
VW - Very Warm SCDR - Collar Shield - Green Textured SPB - Heavy Duty Spike for Line or Low
White MSV - Metallic Silver
Recessed Lens Aqueducts Textured MTP12 - 12" PVC Ground Conduit Mount
SCUA - Collar Shield - GPT - Graphite with 120/12v Stepdown Xformer
MTP18 - 18" PVC Ground Conduit Mount
Flush Lens Aqueducts Textured with 120/12v Stepdown Xformer
S3DR - 30° Cutoff Shield -
Junction Box W/Xformer
Recessed Lens S75T - Single Canopyr & J-Box with 75w
S3UF - 30° Cutoff Shield - 120:12v Stepdown Xformer
ACCESSORIES5
Flush Lens
CFX16 - MR16 Color Filters6 ACCENT & FLOOD
HL16 - MR16 Hexcell Louvers
LS16 - MR16 Linear Spread Lenses
PS16 - MR16 Prismatic Spread Lenses
CC250 - 250' Spool of 12-2 stranded
Low Energy - Underground Cable
NOTES:
1. 16 SS = MR16, 2-Position lamp featuring adjustable Hi/Lo switch, to replicate either 35w or 20w halogen light output levels.
2. 16 HO = MR16, 4-Position lamp featuring adjustable button, to replicate four Halogen light output levels (10w, 20w, 35w or 50w).
3. Color Temperatures; NW = 4,000K, WW = 3,000K, VW = 2,700K.
4. Beam Angle (SS): SP = 19 degree, MF = 34 degree, FL = 60 degree.
(HO): SP = 12 degree, MF = 21 degree, FL = 41 degree.
5. Only Single Accessory Can Be Installed in Shield
6. Color Filters - Replace "X" with required filter color - R-Red, G-Green, B-Blue, Y-Yellow.
7. Transformer is required.
S75T Wall Mount with MTP - Spike (SPB) SPP -
LV Transformer Mounting Spike LV Mounting Spike
with Transformer
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
91
LED ALV PAR20 ACCENT LIGHTS (XALV AL) – LINE VOLTAGE
ACCENT & FLOOD DIMENSIONS SHIELD/LENS ASSEMBLY – Available in six combinations to maximize design flexibility.
Shield is machined from premium alloys to match housing. Lenses are tempered glass.
XALV AL PAR20 LED SCDR Select R – Recessed flat lens or F – Flush machined lens (for improved drainage).
SSDR – Short Shield – Recessed Lens; SSUF – Short Shield – Flush Lens
7.41” (188mm) 2.72” (69mm) SCDR – Collar Shield – Recessed lens & Aqueducts; SCUA – Collar Shield – Flush Lens
and Aqueducts; S3DR – 30° Cutoff Shield – Recessed Lens; S3UF – 30° Cutoff Shield
2” (51mm) – Flush Lens
XALV AL PAR20 LED S3DR 2.72” (69mm) EXPECTED LIFE - Minimum 60,000 hours, depending upon the ambient operating
7.92” (201mm) temperature of the installation location.
2” (51mm) LED MODULE - LED PAR20 Line Voltage, module offers a choice of 3 color temperatures;
Neutral White (NW) - 4000K, Warm White (WW) - 3000K and Very Warm (VW) - 2700K,
XALV AL PAR20 LED SSDR with CRI>80. The lamp features 4 “field selectable” light levels of 100%, 80%, 55% &
6.37” (162mm) 2.72” (69mm) 18%, via an easily accessible push button.
2” (51mm) OPTICS / DISTRIBUTION - Choice of 4 beam patterns; Spot (SP) = 15°, Narrow Flood (NF)
= 23°, Flood (FL) = 35° and Wide Flood (WF) = 51°, that puts the light where it is needed,
in the most efficient way possible. XALV Sign Lights are easy to adjust, aim and lock in
place.
WIRING - Pre-wired with 200°C rated Tefzel wire.
HOUSING - Aluminum housing is CNC machined from premium 6061-T6 alum solid bar
alloy.
MOUNTING - RM – Rear Mount arms have a ½” NPSM threaded stainless steel knuckle for
attachment to J-box or mounts.
ELECTRICAL - 120 VAC, 50/60 HZ input. Complies with UL8750 safety regulations and with
ANSI/IEEE C62.41 Class A operation.
DRIVER - Powered by a fully integrated, constant current, line voltage Class 2 LED driver,
with active power factor correction.
OPERATING TEMPERATURE - -40°C to 55°C (-40°F to +131°F)
FINISH - Standard finishes BRS - Bronze Smooth, WHS – White Smooth and BKS – Black
Smooth. MSV – Metallic Silver, SVG – Satin Verde Green and Graphite are textured
finishes. All finishes are in a UV resistant, thermoset polyester powder coat finish, which
provides durable protection from environmental conditions, corrosion and the elements.
WARRANTY - Limited 5-year warranty.
EXTRA VALUE FEATURES:
• Premium aluminum alloys protected by a chromate conversion process and polyester
powder coat finish, provide XALV Series with incredible corrosion resistance, ensuring a
long life and trouble free operation.
• Precision O-ring sealing system between the lens and housing are high temperature
silicone or Viton fluoroelastomer material, prevents dust and water ingress.
• Posi-Seal provides reliable protection against water and dirt intrusion. No RTV silicone is
used to seal XALV fixtures.
• Available Spread Lenses, Color Filters, and Louvers expand performance.
• Shield/Lens combinations give designers unequalled choice and flexibility.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT - 5 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
LED ARRA IP66
wet location Funding Compliant
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
92 Catalog #
LED ALV PAR20 ACCENT LIGHTS (XALV AL) – LINE VOLTAGE MSV SPB
PRODUCT ORDERING INFORMATION
XALVTYPICAL ORDER EXAMPLE: AL LED20 NW FL 120V S3UF
Prefix Type Light Color Beam Voltage Shield(s) Finish Mounting
XALV AL - Accent Source Temp2 Angle3 120V SSDR - Short Shield - Accessories
LED20 1
(LED ALV - Light NW - Neutral SP - Spot Flood Recessed Lens BKS - Black Smooth NO - None
Line Voltage) White MF - Medium Flood SSUF - Short Shield - BRS - Bronze Smooth
WW - Warm FL - Flood WHS - White Smooth Mounting Spikes
White WF - Wide Flood Flush Lens SVG - Satin Verde SPB - Heavy Duty Spike for Line or Low
VW - Very Warm SCDR - Collar Shield - Green Textured JEP12 - 12" PVC Ground Conduit Mount
White MSV - Metallic Silver JEP18 - 18" PVC Ground Conduit Mount
Recessed Lens Aqueducts Textured
SCUA - Collar Shield - GPT - Graphite Junction Boxes
Textured CFH LB - Composite Grade Mount J-Box
Flush Lens Aqueducts
S3DR - 30° Cutoff Shield - ACCESSORIES4
CFX20 - PAR20 Color Filters5
Recessed Lens HL20 - PAR20 Hexcell Louvers
S3UF - 30° Cutoff Shield -
Flush Lens
LS20 - PAR20 Linear Spread Lenses ACCENT & FLOOD
PS20 - PAR20 Prismatic Spread Lenses
NOTES:
1. PAR20 - LED Module provides choice of 4 field selectable light levels: 100%, 80%, 55% & 18%.
2. Color Temperatures; NW = 4,000K, WW = 3,000K, VW = 2,700K.
3. Beam Angle: SP = 15 degrees, NF = 23 degrees, FL = 35 degrees, WF = 51 degrees.
4. Only Single Filter/Louver Accessory Can Be Installed in Shield
5. Color Filters - Replace "X" with required filter - R-Red, G-Green, B-Blue, Y-Yellow.
JEP - Spike (SPB) CFH LB
Mounting Spike
Junction Box
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
93
LSI LED BULLETS LARGE FLOOD (XBAL)
ACCENT & FLOOD DIMENSIONS 7-13/16” SHIELD – One-piece, die-cast aluminum, 360 alloy, low copper .125” nominal wall thickness
(199mm) shield secures to housing via three, stainless steel recessed hex socket screws. .228” thick
clear tempered glass lens is sealed to shield by a one-piece molded silicone gasket.
(155-07m/8m” ) 7-7/8”
(201mm) EXPECTED LIFE - Minimum 60,000 to 100,000 hours depending upon the ambient
XBAL CSF / CSC 8” temperature of installation location.
12-5/8” (202mm)
(320mm) LEDS - Select high-brightness LEDs in Moon White (6000K nominal) for tree lighting
applications, Cool White (5000K nominal), Neutral White (4000K nominal) or Warm White
6-5/16” (3500K nominal) color temperature, 80 CRI (LW & CW 70 CRI) nominal.
(161mm)
DISTRIBUTION PATTERN - LED module is strategically mounted to interchangeable optical
panels, to deliver a choice of 3 high performance distributions; FL40°, NFL25°, SP10°.
HOUSING - Architecturally styled, one-piece, die-cast aluminum, 360 alloy, low copper
housing features a multi-radius round shape with integral cooling ribs over the back, and
.125” nominal wall thickness. One-piece molded silicone gasket seals the shield to the
housing and is concealed when fixture is closed.
MOUNTING - ½” NPSM mounting arm is standard. Mounting arm may be threaded into
hubs in tree or surface mounts, spikes, junction boxes, or CFH composite J-box. Mounting
arm provides a 200° + range of motion to achieve desired aiming angles.
ELECTRICAL - Surge protection (including separate surge protection built into electronic
driver) IEEE C62.41.2-2002, Scenario 1, Location Category C, 3KV. Available with universal
voltage power supply 120-277VAC (UE - 50/60Hz input).
INTEGRAL DRIVERS - Available in Super Saver (SS) and High Output (HO) drive currents.
Driver components are fully encased in potting for moisture resistance. Complies with IEC
and FCC standards. Optional 0-10V dimming driver available, with controls by others.
OPERATING TEMPERATURE - -40°C to +40°C (-40°F to +104°F).
FINISH - Each fixture is finished with a polyester powder coat process. Standard colors
include bronze, black, platinum plus, white, satin verde green, metallic silver, and graphite.
WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT (IN CARTON) - 7 lbs. (3.2 kg.)
LISTINGS - UL listed to UL 1598, UL8750 and other U.S. and International safety standards.
Suitable for wet locations.
XBAL DSF/DSC This product, or selected versions of this product, meet the standards listed below. Please consult factory
for your specific requirements.
IP66
wet location
LIGHT OUTPUT - XBAL Lumens (Nominal) FL40 Watts
SP10 NFL25 (Nominal)
NEMA Type Lumens LER NEMA Type Lumens LER NEMA Type Lumens LER
LED SS 3H x 3V 2129 101 4H x 3V 1592 76 4H x 4V 1636 78 21
Warm Neutral Cool Moon HO 3H x 2V 2612 93 4H x 3V 1981 70 4H x 4V 2396 86 28
White White White White
SS 3H x 3V 1936 94 4H x 4V 1814 89 4H x 4V 1773 87 21
HO 3H x 3V 2646 97 4H x 4V 2253 82 4H x 4V 2287 84 28
SS 3H x 3V 1823 86 4H x 3V 1367 66 4H x 4V 1613 78 21
HO 3H x 3V 2185 79 4H x 3V 1720 62 4H x 4V 2001 73 28
SS 3H x 3V 1631 78 4H x 3V 1263 60 4H x 4V 1435 69 21
HO 3H x 3V 1984 71 4H x 3V 1589 57 4H x 4V 1862 66 28
LED Chips are frequently updated therefore values may increase.
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
94 Catalog #
LSI LED BULLETS LARGE FLOOD (XBAL)
PRODUCT ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: XBAL SP10 LED HO CW UE BRZ USC
Prefix Distribution Light Drive Color Temp2 Input Voltage Finish Shield/Lens Style
XBAL - SP10 - 10° Spot Source Current1 MW - Moon White UE - Universal BLK - Black USC - Uplight Cast Shield Convex3
NFL25 - 25° Flood HO - High Output CW - Cool White BRZ - Bronze USF - Uplight Cast Shield Flat3
LED Bullet - FL40 - 40° Flood LED SS - Super Saver NW - Neutral White Electronic GPT - Graphite DSC - Downlight Cast Shield Convex4
Large WW - Warm White (120-277V) MSV - Metalic Silver DSF - Downlight Cast Shield Flat4
PLP - Platinum Plus
SVG - Satin Verde ACCESSORIES
JB1 - Architectural J-Box 1/2" Hub
Green J35AH1 - Aluminum J-Box
WHT - White SPB - Mounting Spike PVC J-Box
T - Tree Mount J-Box
J4RSC - Single Canopy & 4" J-Box
CFH LB - Composite J-Box w/ Hub Lid
NOTES: 3.5” 1.4” (36mm) ACCENT & FLOOD
1. Drive currents are HO = 450mA, SS = 350mA. (89mm)
2. Color temperatures are MW = 6000k, CW = 5000k, NW = 4000k, WW = 3200k.
3. Uplight shields are 4 " in length and provides 30 degree cut-off angle.
4. Downlight shields are 9 " in length and provides 60 degree cut-off angle.
3.35Ø 1/2 – 14 NPSM
(85mm)
EXTRUDED ALUMINUM 4.5”
3/4"-14 NPSM 2.3” COVER. COVER GASKET, 1/2-14 NPSM TAP (114mm) 2.25” (57mm)
(58mm) & MOUNTINGSCREW
.84” (21mm) 3.5” 5”
PROVIDED. 1 EA. 1/2-14 2.25” (57mm) (89mm) (127mm)
NPSM PLUG PROVIDED
(4x) 15.25”
2.47” (387mm)
(63mm) (BURIED)
8.2”
4.5” 3/4-14 NPT PIPE TAP 2X (208mm)
(114mm)
1.4” (36mm) 1.7” (43mm)
1.532 3.063” (78mm) 1.75” 7.5”
1.25” (32mm) (44mm) (191mm)
1/2"-1(42XN)PSM J35AH1 Aluminum J-Box (2x)
1.625” (41mm)
INTERIOR VOLUME 16.5 in (SPB) Heavy Duty PVC Spike J-Box
JB1 Architectural J-Box
3/4-14 NPS (4X) 7.85”
(199mm)
1.97” 8.7”
(50mm) (221mm)
3.93” 1.81”
(100mm) (46mm)
JCuonvcetrion Box 1/2-14 NPS HUB 3.93” 2.04”
(100mm) (52mm)
5.16” 2.4” 2.16” 2.38”
(131mm) (61mm) (55mm) (60mm)
4.86”
(123mm) 1.75”
(44mm)
3” 1/2” 1/2” 2.12”
(76mm) NPS NPS tap center (54mm)
threaded back box
(T) Tree Mount J-Box hub 1.5”
(38mm)
.71”
(18mm) 3.8”
(96mm)
J4R SC or J4R SCE 4” J-Box
5.84”
(148mm)
CFH LB Composite J-Box w/Hub Lid
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
95
LSI LED BULLETS MEDIUM FLOOD (SBAM)
ACCENT & FLOOD DIMENSIONS SHIELD – Fixture features a built-in visor to better control beam pattern and minimize spill of
light into adjacent properties.
EXPECTED LIFE - Minimum 50,000 hours depending upon the ambient temperature of the
installation location.
LEDS - Features an array of select LED chips; CW - 4700K color temperature, with a CRI of
75 (nominal).
OPTICS / DISTRIBUTION - Multiple LED modules and lenses are strategically mounted
to the optical panel / heat sink, to distribute light in a tightly controlled beam pattern that
puts light where it is needed, in the most efficient way possible. It delivers a 4H x 4V
distribution.
HOUSING - Precision designed die-cast aluminum housing with stainless steel hardware,
tempered glass lens and silicon gaskets.
MOUNTING - ½” NPSM mounting arm is standard. Mounting arm may be threaded into
hubs in tree or surface mounts, spikes, junction boxes, or CFH style ballast enclosures.
Adjustable mounting arm provides angle markings, for accurate and easy aiming.
ELECTRICAL - Universal voltage power supply, 120-277 VAC, 50/60 HZ input. Powered by
a constant current, high efficiency Class 2 LED driver, with active power factor correction,
an IP66 rating and all around protection against over-voltage, over-temperature and short
circuit conditions as well as lightning protection. Driver has a Class A EMI rating and
complies with UL8750 safety regulations and with ANSI/IEEE C62.41 Class A operation.
DRIVERS - Available in High Output (HO) drive current, to provide the highest lumen output
approach.
OPERATING TEMPERATURE - -30°C to +40°C (-22°F to +104°F).
FINISH - Standard colors are Black, Bronze or Verde Green in a UV resistant, thermoset
polyester powder coat finish, which provides durable protection from environmental
conditions, corrosion and the elements.
WARRANTY - Limited 5-year warranty.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT - 5 lbs.
LISTINGS - UL listed to UL8750. Suitable for wet locations.
LIGHT OUTPUT - SBAM Watts This product, or selected versions of this product, meet the standards listed below. Please consult factory
Lumens LPW for your specific requirements.
Cool SBAM 1140 15 74 IP66
White1
1 - 4700K CCT standard. wet location
LED Chips are frequently updated therefore values may increase.
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
96 Catalog #
LSI LED BULLETS MEDIUM FLOOD (SBAM)
PRODUCT ORDERING INFORMATION
TYPICAL ORDER EXAMPLE: SBAM FL LED HO NW UE BLK
Prefix Distribution Light Drive Color Temp1 Input Voltage Finish Options
SBAM - FL - Flood 4H x 4V Source Current NW - Neutral White UE - Universal BLK - Black None
HO - High Output BRZ - Bronze ACCESSORIES
LED Bullet - LED Electronic VG - Verde Green JB1 - Architectural J-Box 1/2" Hub
Medium (120-277V) J35AH1 - Aluminum J-Box
SPB - Mounting Spike PVC J-Box
T - Tree Mount J-Box
J4RSC - Single Canopy & 4" J-Box
CFH LB - Composite J-Box w/ Hub Lid
NOTES: ACCENT & FLOOD
1. Standard oolor temperature is Neutral White (NW) - 4700K CCT. Consult factory for availability of optional color
temperatures.
3.5” 1.4” (36mm)
(89mm)
3.35Ø
(85mm) 1/2 – 14 NPSM
3/4"-14 NPSM EXTRUDED ALUMINUM 1/2-14 NPSM TAP 4.5” 2.25” (57mm)
2.3” COVER. COVER GASKET, (114mm)
(58mm) & MOUNTINGSCREW
.84” (21mm) 3.5” 5”
PROVIDED. 1 EA. 1/2-14 2.25” (57mm) (89mm) (127mm)
NPSM PLUG PROVIDED
(4x) 15.25”
2.47” (387mm)
(63mm) (BURIED)
8.2”
4.5” 3/4-14 NPT PIPE TAP 2X (208mm)
(114mm)
1.4” (36mm) 1.7” (43mm)
1.532 3.063” (78mm) 1.75” 7.5”
1.25” (32mm) (44mm) (191mm)
1/2"-1(42XN)PSM J35AH1 Aluminum J-Box (2x)
1.625” (41mm)
INTERIOR VOLUME 16.5 in (SPB) Heavy Duty PVC Spike J-Box
JB1 Architectural J-Box
3/4-14 NPS (4X) 7.85”
(199mm)
1.97” 8.7”
(50mm) (221mm)
3.93” 1.81”
(100mm) (46mm)
CJuonvcetrion Box 1/2-14 NPS HUB 3.93” 2.04”
(100mm) (52mm)
5.16” 2.4” 2.16” 2.38”
(131mm) (61mm) (55mm) (60mm)
4.86”
(123mm) 1.75”
(44mm)
3” 1/2” 1/2” 2.12”
(76mm) NPS NPS tap center (54mm)
threaded back box
(T) Tree Mount J-Box hub 1.5”
(38mm)
.71”
(18mm) 3.8”
(96mm)
J4R SC or J4R SCE 4” J-Box
5.84”
(148mm)
CFH LB Composite J-Box w/Hub Lid
LED
Project Name Fixture Type © 2015
Catalog # LSI INDUSTRIES INC.
97
LSI LED BULLETS SMALL FLOOD (SBAS)
SHIELD – Fixture features a built-in visor to better control beam pattern and minimize spill
of light into adjacent properties.
EXPECTED LIFE - Minimum 50,000 hours depending upon the ambient temperature of the
installation location.
LEDS - Features an array of select LED chips; CW - 4700K color temperature, with a CRI of
75 (nominal).
OPTICS / DISTRIBUTION - Multiple LED modules and lenses are strategically mounted
to the optical panel / heat sink, to distribute light in a tightly controlled beam pattern that
puts light where it is needed, in the most efficient way possible. It delivers a 3H x 3V
distribution.
HOUSING - Precision designed die-cast aluminum housing with stainless steel hardware,
tempered glass lens and silicon gaskets.
ACCENT & FLOOD DIMENSIONS MOUNTING - ½” NPSM mounting arm is standard. Mounting arm may be threaded into
hubs in tree or surface mounts, spikes, junction boxes, or CFH style ballast enclosures.
Adjustable mounting arm provides angle markings, for accurate and easy aiming.
ELECTRICAL - Universal voltage power supply, 120-277 VAC, 50/60 HZ input. Powered by
a constant current, high efficiency Class 2 LED driver, with active power factor correction,
an IP66 rating and all around protection against over-voltage, over-temperature and short
circuit conditions as well as lightning protection. Driver has a Class A EMI rating and
complies with UL8750 safety regulations and with ANSI/IEEE C62.41 Class A operation.
DRIVERS - Available in Super Saver (SS) drive current, to provide the most energy efficient
approach.
OPERATING TEMPERATURE - -30°C to +40°C (-22°F to +104°F).
FINISH - Standard colors are Black, Bronze or Verde Green in a UV resistant, thermoset
polyester powder coat finish, which provides durable protection from environmental
conditions, corrosion and the elements.
WARRANTY - Limited 5-year warranty.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed
photometric data.
SHIPPING WEIGHT - 3 lbs.
LIGHT OUTPUT - SBAS Watts LISTINGS - UL listed to UL8750. Suitable for wet locations.
Lumens
LPW
Cool SBAS 778 11 69 This product, or selected versions of this product, meet the standards listed below. Please consult factory
White1 for your specific requirements.
IP66
1 - 4700K CCT standard.
LED Chips are frequently updated therefore values may increase. wet location
LED
Project Name Fixture Type © 2015
LSI INDUSTRIES INC.
98 Catalog #