The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by McCrometer, 2020-11-05 11:15:04

Ag Resource Binder (English)

Specification Sheet
MW600 Weld-on Saddle Flow Meter



DESCRIPTION

• The Model MW600 is manufactured to
comply with applicable provisions of AWWA
Standard No. C704-02 for propeller-type
flowmeters.
• As with all McCrometer propeller
flowmeters, standard features include a
magnetically coupled drive, instantaneous
flowrate indicator and straight reading, six-
digit totalizer.
• Model MW600 Weld-On Saddle Meter is
machined to the same radius as the tube on
which it is to be installed to provide accurate
alignment.






Typical Applications

FEATURES
The McCrometer propeller meter is the most
Weldment widely used flowmeter for municipal and
wastewater treatment applications as well as
• The meter head weldment is either Stainless agricultural and turf irrigation measurement.
Steel or fusion-bonded epoxy coated carbon Typical applications include:
steel for maximum corrosion protection.
• Water and wastewater management
Impellers
• Center pivot systems
• Impellers are manufactured of high-impact • Sprinkler irrigation systems
plastic, capable of retaining their shape and • Drip irrigation systems
accuracy over the life of the meter. • Golf course and park water management
• Each impeller is individually calibrated at • Gravity turnouts for underground pipelines
the factory to accommodate the use of any • Commercial nurseries
standard McCrometer register, and since no
change gears are used, the MW600 can be Register
field-serviced without the need for factory • The instantaneous flowrate indicator is standard
recalibration. and available in gallons per minute, cubic feet per
Bearings second, liters per second and other units.

• Factory lubricated, stainless steel bearings • The register is driven by a flexible steel cable
are used to support the impeller shaft. encased within a protective vinyl liner.
• The shielded bearing design limits the entry • The register housing protects both the register
of materials and fluids into the bearing and cable drive system from moisture while
chamber providing maximum bearing allowing clear reading of the flowrate indicator
protection. and totalizer.







24517-21 Rev. 2.3 | 23MAR2020

Specification Sheet
MW600 Weld-on Saddle Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise the
factory. A straight run of full pipe the length of ten pipe diameters upstream and two diameters downstream of
the meter is recommended for meters without straightening vanes. Meters with optional straightening vanes
require at least five pipe diameters upstream and two diameters downstream of the meter.

SPECIFICATIONS


Performance
• ±2% of reading guaranteed throughout full range.
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 4” to 48”
Maximum (Standard Construction) 160°F constant
Temperature

Pressure Rating 150 psi. Consult factory for higher rated version.
Materials
Top Plate Stainless steel (4”) or fusion-bonded epoxy coated carbon steel (6” and larger)

Weldment Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel.
Magnets Permanent type. Alnico.
Bearing Housing • For models 4” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case. This
protective housing includes a domed acrylic lens and hinged lens cover with locking
hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and accuracy
over the life of the meter. High temperature impeller is optional.
Options

• Extended warranty
• Weld-on saddle can be profiled to fit any outside diameter pipe dimensions
• Register extensions

• High temperature construction 180°F
• Marathon bearing assembly for higher than normal flowrates
• Digital register available in all sizes of this model
• A complete line of flow recording/control instrumentation
• Canopy boot







Page 2 24517-21 Rev. 2.3 | 23MAR2020

Specification Sheet
MW600 Weld-on Saddle Flow Meter


DIMENSIONS



C





B








A


MW600 DIMENSIONS
Meter Size 4 6 8 10 12 14 16 18 20 24 30 36 42 48
(inches)
Minimum Flow 50 90 100 125 150 250 275 400 475 700 1200 1500 2000 2500
U.S. GPM
Maximum Flow 600 1200 1500 1800 2500 3000 4000 5000 6000 8500 12500 17000 25000 30000
U.S. GPM
Maximum Flow
w/ Marathon 900 1800 2250 2700 3750 4500 6000 7500 9000 12750 18750 25500 37500 45000
Bearing
Approx. Head
Loss in Inches at 23 17 6.75 3.75 2.75 2 1.75 1.5 1.25 1 0.7 0.5 0.45 0.3
Max. Flow
Standard Dial 800/ 1300/ 2500/ 3000/ 4000/ 6000/ 8000/ 10000/ 10000/ 15000/ 15000/ 30000/ 35000/ **
Face (GPM/Gal) 100 100 100 1000 1000 1000 1000 1000 10000 10000 10000 10000 1000

Approx.
Shipping 30 45 70 90 120 125 130 150 175 190 205 210 220 230
Weight-lbs.
A (inches) 11.37 12.87 12.87 12.12 12.12 12.12 12.12 15 15 15 15 15 15 15
B (inches) 10.75 10.75 11.75 13.75 14.75 14.75 16.75 16.75 18.75 20.75 22.38 26.38 29.38 32.38
C (inches) * 5 ½ 7 ½ 7 ½ 10 ¾ 10 ¾ 10 ¾ 10 ¾ 12 ¾ 12 ¾ 12 ¾ 18 20 20 20
No. of Top Plate 6 8 8 12 12 12 12 16 16 16 16 16 Contact
Bolts Factory
* Dimension C is O.D. of saddle.
** Per customer requirements. Larger flowmeters on special order.
To order:
Specify pipe I.D. and O.D. The pipe O.D. determines the meter size. The model number is established by taking the pipe O.D. to the next larger
size. For example, a 14” cast iron pipe with a 15.3” O.D. would be a 16” meter, or a model ‘MW616.’








Page 3 24517-21 Rev. 2.3 | 23MAR2020

SADDLE Specification Sheet
MW600 Weld-on Saddle Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.


PIPE RUN REQUIREMENTS



Confi guration A B
Without straightening vanes 10 1
With straightening vanes 5 1
With FS100 Flow Straightener 1.5 1
Flow B


15”

A


Measure 15” from center of
ell to determine average
location of the propeller tip.




Elbow shown - Other piping components can be
pumps, valves and expansions or reductions


STRAIGHTENING VANES

Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal


sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can
travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.


















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-21 Rev. 2.3 | 23MAR2020

Specification Sheet
MW600 Weld-on Saddle Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer

The instantaneous owrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.






Wireless Telemetry

The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-21 Rev. 2.3 | 23MAR2020



Specification Sheet
L0200 Bolt-On Meter Head Assembly



DESCRIPTION

The model L0200 can replace an existing
meter head or kept as a spare for those meter
locations that cannot have significant down-
time.
The meter head bolts to any McCrometer
meter that accepts a standard meter head
assembly, including models MW500, MW600,
MW900, MT900, and MG900.
All Mc Propeller flow meters are manufactured
to comply with applicable provisions of AWWA
Standard No. C704-02 for propeller-type flow
meters.


FEATURES

Impellers
• Impellers are manufactured of high-impact
plastic, capable of retaining their shape and Typical Applications
accuracy over the life of the meter.
• Each impeller is individually calibrated at The Mc propeller meter is the most widely
the factory to accommodate the use of any used flowmeter for municipal and wastewater
standard McCrometer register, and since no treatment applications as well as agricultural
change gears are used, the meter can be and turf irrigation measurement. Typical
field-serviced without the need for factory applications include:
recalibration. • Water and wastewater management
Bearings • Center pivot systems
• Sprinkler irrigation systems
• Factory lubricated stainless steel bearings • Drip irrigation systems
are used to support the impeller shaft. • Golf course and park water management
• The shielded bearing design limits the entry • Gravity turnouts for underground pipelines
of materials and fluids into the bearing • Commercial nurseries
chamber, providing maximum bearing
protection.
Register
• The register housing protects both the register
• The instantaneous flowrate indicator is and cable drive system from moisture while
standard and available in gallons per minute, allowing clear reading of the flowrate indicator
cubic feet per second, liters per second and and totalizer.
other engineering units.

• The register is driven by a flexible steel cable
with a magnetically coupled drive, encased
within a protective vinyl liner.










24510-21 Rev. 1.7 | 23MAR2020

Specification Sheet
L0200 Bolt-On Meter Head Assembly


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 2” to 36”
Maximum
Temperature (Standard Construction) 160°F constant
Pressure Rating 150 psi. Consult factory for higher rated version.
Environmental NEMA 4X
Rating
Materials
Top Plate Stainless steel (2” to 4”) or fusion-bonded epoxy coated carbon steel (6” and larger)
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel

Magnets (Permanent type) Alnico
Bearing Housing • For models 2” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional

Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.

Options
• Extended warranty
• Register extensions

• High temperature construction, 180°F max
• Marathon bearing assembly for higher than normal flowrates
• Digital propeller meter available for model sizes 4” and larger
• A complete line of flow recording/control instrumentation

• Canopy boot





















Page 2 24510-21 Rev. 1.7 | 23MAR2020

Specification Sheet
L0200 Bolt-On Meter Head Assembly


DIMENSIONS



C






B









Plate
Centerline
A



L0200 DIMENSIONS
2,
Meter Size (inches) 4 6 8 10 12 14 16 18 20 24 30 36
2.5, 3
OD up to (inches) 5.5 7.5 9.5 11.5 13.5 15.5 17.5 19.5 21.5 26.5 32.5 38.5
L0233- L0234- L0235- L0236- L0237- L0238- L0239- L0240- L0241- L0242- L0243- L0243-
Part No. **
10 10 10 10 10 10 10 10 10 10 10 30
Minimum Flow U.S. 40 50 90 100 125 150 250 275 400 475 700 1200 1500
GPM
Maximum Flow U.S. 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500 12500 17000
GPM
Maximum Flow w/ 900 1800 2250 2700 3750 4500 6000 7500 9000 12750 18750 25500
Marathon Bearing
Approx. Head Loss in 1.06 .83 .61 .24 .14 .1 .07 .06 .05 .05 .04 .03 .02
psi at Max. Flow
Standard Dial Face 250/ 1000/ 1800/ 2500/ 3K/ 4K/ 6K/ 8K/ 10K/ 10K/ 15K/ 15K/ 30K/
(GPM/Gal)* 10 100 100 100 1000 1000 1000 1000 1000 10K 10K 10K 10K
A* (inches) 8.5 11.37 12.87 12.87 12.12 12.12 12.12 12.12 15.00 15.00 15.00 15.00 15.00
B (inches) 9.5 10.75 10.75 11.75 13.75 14.75 14.75 16.75 16.75 18.75 20.75 22.38 26.38
C (inches) 4.5 5.5 7.5 7.5 10.75 10.75 10.75 10.75 12.75 12.75 12.75 18 20
Approx. Shipping 36 30 45 70 90 120 125 130 150 175 190 205 210
Weight-lbs.
No. of Top Plate Bolts 6 6 8 8 12 12 12 12 16 16 16 16 16
*Dimension A is from center of meter head weldment.

**Use L0232-10 for meters built prior to January 1, 2000, and L0232-20 for meters built after January 1, 2000 and
beginning with serial #00-7974-XX.
On ordering, please specify serial number of existing meter head assembly.











Page 3 24510-21 Rev. 1.7 | 23MAR2020

Specification Sheet
L0200 Bolt-On Meter Head Assembly


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1
15”
Flow



A





Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions



STRAIGHTENING VANES


Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal
sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can


travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.



















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24510-21 Rev. 1.7 | 23MAR2020

Specification Sheet
L0200 Bolt-On Meter Head Assembly


TOTALIZERS

Typical face plates

2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000
500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register




Mechanical Totalizer


The instantaneous owrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.





Wireless Telemetry


The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.


Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24510-21 Rev. 1.7 | 23MAR2020



Specification Sheet
MW500 / MZ500 Flanged Main Line Flow Meter



DESCRIPTION

Model MW500 and MZ500 main line propeller
flow meters are manufactured to comply with
AWWA Standard No. C704-02 for propeller
type flowmeters.
• Model MW500 is designed for a maximum
continuous working pressure of up to 150
psi and is fitted with AWWA Class D flanges.

• Model MZ500 is designed for a continuous
working pressure of up to 300 psi and is
fitted with ANSI B16.5 Class 300 flanges.
As with all McCrometer propeller flowmeters,
standard features include a magnetically
coupled drive, instantaneous flowrate
indicator and straight reading, six-digit
totalizer. The MW500 and MZ500 can be
field-serviced without the need for factory
recalibration.
Typical Applications
FEATURES
The McCrometer propeller meter is the most
Top Plate / Meter Head Weldment widely used flowmeter for municipal and
wastewater treatment applications as well as
• The meter head weldment is either stainless agricultural and turf irrigation measurement.
steel or fusion-bonded epoxy coated carbon Typical applications include:
steel for maximum corrosion protection.
• Water and wastewater management
• The top plate is either stainless steel (for sizes • Center pivot systems
2” to 4”) or fusion-bonded epoxy coated
carbon steel (6” and larger). • Sprinkler irrigation systems
• Drip irrigation systems
Impellers • Golf course and park water management
• Impellers are manufactured of high-impact • Gravity turnouts from underground pipelines
plastic, capable of retaining their shape and • Commercial nurseries
accuracy over the life of the meter.
• The shielded bearing design limits the entry of
• Each impeller is individually calibrated at
the factory to accommodate the use of any materials and fluids into the bearing chamber
standard McCrometer register. providing maximum bearing protection.
Register
• The impeller and drive assembly are easily
removed through the top flange connection. The instantaneous flowrate indicator is standard
The meter flow tubes are coated with fusion- and available in gallons per minute, cubic feet
bonded epoxy for maximum corrosion per second, liters per second and other units. The
protection, and integral flow straightening register is driven by a flexible steel cable encased
vanes reduce upstream flow turbulence. within a protective vinyl liner. The register housing
protects both the register and cable drive system
Bearings
from moisture while allowing clear reading of the
• Factory lubricated stainless steel bearings flowrate indicator and totalizer.
are used to support the impeller shaft.





24517-20 Rev. 2.5 | 23MAR2020

Specification Sheet
MW500 / MZ500 Flanged Main Line Flow Meter

SPECIFICATIONS


Performance

• ±2% of reading guaranteed throughout the full range
Accuracy /
Repeatability • ± 1% over the reduced range
• Repeatability 0.25% or better
Range 2” to 36”
Maximum
Temperature (Standard construction) 160°F constant
Pressure Rating • Model MW500: 150 psi
• Model MZ500: 300 psi

Materials
Top Plate Stainless steel (2” to 4”) or fusion-bonded epoxy coated carbon steel (6” and larger)
Top Plate Weldment Stainless steel (2” to 4”) or fusion-bonded epoxy coated carbon steel (6” and larger)
Spool Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Body Epoxy-coated carbon steel pipe conforming to ANSI/ASME pipe schedules

Magnets (Permanent type) Alnico
Bearing Housing • For models 2” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are standard.
The register is hermetically sealed within a die cast aluminum case. This protective housing
includes a domed acrylic lens and hinged lens cover with locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and accuracy over
the life of the meter. High temperature impeller is optional.

Options
• International flange standards available
• Other than standard laying lengths available
• Register extensions available
• All stainless steel construction
• High temperature construction
• “Over Run” bearing assembly for higher-than-normal flowrates
• Electronic propeller meter available in all sizes of this model
• A complete line of flow recording/control instrumentation
• Certified calibration test results
• Canopy boot



















Page 2 24517-20 Rev. 2.5 | 23MAR2020

Specification Sheet
MW500 / MZ500 Flanged Main Line Flow Meter


DIMENSIONS - MW500

FLOW


















MW500 DIMENSIONS
inches 2 2 ½ 3 4 6 8 10 12 14 16 18 20 24 30 36
Meter Size
mm 51 64 76 102 152 203 254 305 356 406 457 508 610 762 914
GPM 40 40 40 50 90 100 125 150 250 275 400 475 700 1200 1500
Minimum Flow
LPS 2.5 2.5 2.5 3.2 5.7 6.3 7.9 9.5 15.8 17.3 25.2 30 44.2 75.7 94.6
GPM 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500 12500 17000
Maximum Flow
LPS 15.8 15.8 15.8 37.9 75.7 94.6 113.6 157.7 189.3 252.4 315.5 378.5 536.3 788.6 1072.5
Maximum Flow w/ GPM n/a n/a n/a 900 1800 2250 2700 3750 4500 6000 7500 9000 12750 18750 25500
Marathon Bearing
Approx. Head Loss inches 29.5 29.5 29.5 23 17 6.75 3.75 2.75 2 1.75 1.5 1.25 1 1 1
in Inches at Max.
Flow mm 749 749 749 584 432 172 95 70 51 45 38 32 25 25 25
Standard Dial GPM/ 250/ 250/ 250/ 1000/ 1800/ 2500/ 3000/ 4000/ 6000/ 8000/ 10000/ 10000/ 15000/ 15000/ 30000/
Face* Gal 10 10 10 100 100 100 1000 1000 1000 1000 1000 10000 10000 10000 10000
Approx. Shipping lbs 36 36 43 54 115 135 197 325 465 530 744 890 1,293 1450 1650
Weight, lbs. kg 16.3 16.3 19.5 24.5 52.2 61.2 89.4 147.4 210.9 240.4 337.5 403.7 586.5 657.7 748.4
inches 0.75 0.75 0.75 0.75 0.875 0.875 1 1 1.125 1.125 1.25 1.25 1.375 1.375 1.625
B
mm 19 19 19 19 22 22 25 25 29 29 32 32 35 35 41
inches 4.75 5.5 6 7.5 9.5 11.75 14.25 17 18.75 21.25 22.75 25 29.5 36 42.75
C
mm 121 140 152 191 242 299 362 432 476 540 578 635 749 914 1086
inches 6 7 7.5 9 11 13.5 16 19 21 23.5 25 27.5 32 38.75 46
D
mm 553 179 191 229 279 341 406 483 533 597 635 699 813 984 1168
inches 11.75 12.25 12.5 15.25 16.25 18.5 21.75 24.25 25.25 28.5 29.25 32.5 36.75 42.75 49.25
H
mm 299 311 318 387 413 470 553 616 641 724 743 826 934 1086 1251
inches 14 16 16 20 22 24 26 28 42 48 54 60 60 60 60
L
mm 356 406 406 508 559 610 660 711 1067 1219 1372 1524 1524 1524 1524
No. of Bolts per Flange 4 4 4 8 8 8 12 12 12 16 16 20 20 28 32
No. of Topplate Bolts 6 6 6 6 8 8 12 12 12 12 16 16 16 16 16
*Indicates the dial face range and multiplier

Note: Flanges meet ASTM-A-181 specs. Larger flowmeters on special order.

McCROMETER reserves the right to change design or specifications without notice.




MZ500 DIMENSIONS
inches 2 2 ½ 3 4 6 8 10 12 14 16 18 20 24 30 36
Meter Size
mm 51 64 76 102 152 203 254 305 356 406 457 508 610 762 914
GPM 40 40 40 50 90 100 125 150 250 275 400 475 700 1200 1500
Minimum Flow
LPS 2.5 2.5 2.5 3.2 5.7 6.3 7.9 9.5 15.8 17.3 25.2 30 44.2 75.7 94.6
GPM 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500 12500 17000
Maximum Flow
LPS 15.8 15.8 15.8 37.9 75.7 94.6 113.6 157.7 189.3 252.4 315.5 378.5 536.3 788.6 1072.5
Maximum Flow w/ GPM n/a n/a n/a 900 1800 2250 2700 3750 4500 6000 7500 9000 12750 18750 25500
Marathon Bearing
Approx. Head Loss inches 29.5 29.5 29.5 23 17 6.75 3.75 2.75 2 1.75 1.5 1.25 1 1 1
in Inches at Max. Page 3 24517-20 Rev. 2.5 | 23MAR2020
Flow mm 749 749 749 584 432 172 95 70 51 45 38 32 25 25 25
Standard Dial GPM/ 250/ 250/ 250/ 1000/ 1800/ 2500/ 3000/ 4000/ 6000/ 8000/ 10000/ 10000/ 15000/ 15000/ 30000/
Face* Gal 10 10 10 100 100 100 1000 1000 1000 1000 1000 10000 10000 10000 10000
Approx. Shipping lbs 50 55 62 90 145 220 340 430 650 820 1,315 1,508 2,165
Weight, lbs. kg 22.7 24.9 28.1 40.8 65.8 99.8 154.2 195 294.8 371.9 596.5 684 982
inches 0.75 0.875 0.875 0.875 0.875 1 1.125 1.25 1.25 1.375 1.375 1.375 1.625
B
mm 19 22 22 22 22 25 29 32 32 35 35 35 41
inches 5 5.875 6.625 7.875 11 13 15.25 17.75 20.25 22.5 24.75 27 32
C
mm 127 149 168 200 279 330 387 451 514 572 629 686 813
inches 6.5 7.5 8.25 10 12.5 15 17.5 20.5 23 25.5 28 30.5 36
D
mm 165 191 210 254 318 381 445 521 584 648 711 775 914
inches 12 12.5 12.875 15.75 17 19.25 22.5 25 26.25 29.5 32.75 34 38.75
H
mm 305 318 327 400 432 489 572 635 667 749 832 864 984
inches 20 20 20 24 26 28 30 32 42 48 54 60 60
L
mm 508 508 508 610 660 711 762 813 1067 1219 1372 1524 1524
No. of Bolts per Flange 8 8 8 8 12 12 16 16 20 20 24 24 24
*Indicates the dial face range and multiplier
Note: Flanges meet ASTM-A-181 specs. Larger flowmeters on special order.


McCROMETER reserves the right to change design or specifications without notice.

MW500
2
10
2 ½
16
30
24
20
14
6
12
3
18
4
36
8
Meter Size
51
305
152
356
mm
610
914
76
102
254
762
457
203
406
508
64
GPM
400
275
50
40
90
100
125
150
250
40
40
475
1200
700
1500
Minimum Flow
LPS
44.2
30
15.8
9.5
75.7
2.5
6.3
7.9
2.5
3.2
2.5
94.6
25.2
17.3
5.7
GPM
250
8500
1500
6000
12500
2500
250
1200
5000
250
3000
17000
4000
1800
600
Maximum Flow
LPS
252.4
788.6
378.5
157.7
536.3
37.9
189.3
94.6
315.5
75.7
Maximum Flow w/
7500
n/a
2250
900
2700
n/a
25500
12750
9000
1800
4500
18750
n/a
3750
GPM
6000
Marathon Bearing
1
23
6.75
Approx. Head Loss
17
29.5
2
1
2.75
inches
1.5
1.25
1.75
3.75
29.5
29.5
1
in Inches at Max.
45
25
38
25
70
95
25
172
51
32
749
mm
749
749
584
432
Flow
Standard Dial
GPM/
6000/
250/
4000/
250/
250/
30000/
3000/
1000
1000
1000
10000
Gal
10000
1000
10000
10000
10
1000
Face* inches 15.8 15.8 15.8 1000/ 1800/ 2500/ 113.6 DIMENSIONS 8000/ 10000/ 10000/ 15000/ 15000/ 1072.5
100
100
100
10
10
Approx. Shipping lbs 36 36 43 54 115 135 197 325 465 530 744 890 1,293 1450 1650
Weight, lbs. kg 16.3 16.3 19.5 24.5 52.2 61.2 89.4 147.4 210.9 240.4 337.5 403.7 586.5 657.7 748.4
Specification Sheet
inches 0.75 0.75 0.75 0.75 0.875 0.875 1 1 1.125 1.125 1.25 1.25 1.375 1.375 1.625
B
MW500 / MZ500 Flanged Main Line Flow Meter
mm 19 19 19 19 22 22 25 25 29 29 32 32 35 35 41
inches 4.75 5.5 6 7.5 9.5 11.75 14.25 17 18.75 21.25 22.75 25 29.5 36 42.75
C mm 121 140 152 191 242 299 362 432 476 540 578 635 749 914 1086
DIMENSIONS - MZ500 7.5 9 11 13.5 16 19 21 23.5 25 27.5 32 38.75 46
7
inches
6
D
mm 553 179 191 229 279 341 406 483 533 597 635 699 813 984 1168
FLOW
inches 11.75 12.25 12.5 15.25 16.25 18.5 21.75 24.25 25.25 28.5 29.25 32.5 36.75 42.75 49.25
H
mm 299 311 318 387 413 470 553 616 641 724 743 826 934 1086 1251
inches 14 16 16 20 22 24 26 28 42 48 54 60 60 60 60
L
mm 356 406 406 508 559 610 660 711 1067 1219 1372 1524 1524 1524 1524
No. of Bolts per Flange 4 4 4 8 8 8 12 12 12 16 16 20 20 28 32
No. of Topplate Bolts 6 6 6 6 8 8 12 12 12 12 16 16 16 16 16
*Indicates the dial face range and multiplier

Note: Flanges meet ASTM-A-181 specs. Larger flowmeters on special order.
McCROMETER reserves the right to change design or specifications without notice.

MZ500 DIMENSIONS
inches 2 2 ½ 3 4 6 8 10 12 14 16 18 20 24 30 36
Meter Size
mm 51 64 76 102 152 203 254 305 356 406 457 508 610 762 914
GPM 40 40 40 50 90 100 125 150 250 275 400 475 700 1200 1500
Minimum Flow
LPS 2.5 2.5 2.5 3.2 5.7 6.3 7.9 9.5 15.8 17.3 25.2 30 44.2 75.7 94.6
GPM 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500 12500 17000
Maximum Flow
LPS 15.8 15.8 15.8 37.9 75.7 94.6 113.6 157.7 189.3 252.4 315.5 378.5 536.3 788.6 1072.5
Maximum Flow w/ GPM n/a n/a n/a 900 1800 2250 2700 3750 4500 6000 7500 9000 12750 18750 25500
Marathon Bearing
Approx. Head Loss inches 29.5 29.5 29.5 23 17 6.75 3.75 2.75 2 1.75 1.5 1.25 1 1 1
in Inches at Max.
Flow mm 749 749 749 584 432 172 95 70 51 45 38 32 25 25 25
Standard Dial GPM/ 250/ 250/ 250/ 1000/ 1800/ 2500/ 3000/ 4000/ 6000/ 8000/ 10000/ 10000/ 15000/ 15000/ 30000/
Face* Gal 10 10 10 100 100 100 1000 1000 1000 1000 1000 10000 10000 10000 10000
Approx. Shipping lbs 50 55 62 90 145 220 340 430 650 820 1,315 1,508 2,165
Weight, lbs. kg 22.7 24.9 28.1 40.8 65.8 99.8 154.2 195 294.8 371.9 596.5 684 982
inches 0.75 0.875 0.875 0.875 0.875 1 1.125 1.25 1.25 1.375 1.375 1.375 1.625
B
mm 19 22 22 22 22 25 29 32 32 35 35 35 41
inches 5 5.875 6.625 7.875 11 13 15.25 17.75 20.25 22.5 24.75 27 32
C
mm 127 149 168 200 279 330 387 451 514 572 629 686 813
inches 6.5 7.5 8.25 10 12.5 15 17.5 20.5 23 25.5 28 30.5 36
D
mm 165 191 210 254 318 381 445 521 584 648 711 775 914
inches 12 12.5 12.875 15.75 17 19.25 22.5 25 26.25 29.5 32.75 34 38.75
H
mm 305 318 327 400 432 489 572 635 667 749 832 864 984
inches 20 20 20 24 26 28 30 32 42 48 54 60 60
L
mm 508 508 508 610 660 711 762 813 1067 1219 1372 1524 1524
No. of Bolts per Flange 8 8 8 8 12 12 16 16 20 20 24 24 24
*Indicates the dial face range and multiplier

Note: Flanges meet ASTM-A-181 specs. Larger flowmeters on special order.

McCROMETER reserves the right to change design or specifications without notice.
Page 4 24517-20 Rev. 2.5 | 23MAR2020

Specification Sheet
MW500 / MZ500 Flanged Main Line Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1

Flow 15”




A Measure 15” from center of
ell to determine average
location of the propeller tip.


Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions




STRAIGHTENING VANES

Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal
sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can


travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.



















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 5 24517-20 Rev. 2.5 | 23MAR2020

Specification Sheet
MW500 / MZ500 Flanged Main Line Flow Meter


TOTALIZERS

Typical face plates

2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000
500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register




Mechanical Totalizer

The instantaneous owrate indicator is standard and available in gallons per

minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.





Wireless Telemetry


The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.


Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 6 24517-20 Rev. 2.5 | 23MAR2020

Specification Sheet
MW900/MG900/MT900 Main Line Flow Meter



DESCRIPTION

Models MW900, MG900 and MT900 are
manufactured to comply with the applicable
provisions of AWWA Standard No. C704-02 for
propeller type flowmeters.
The 900 series is manufactured in three
different end connections:
• MW900 with beveled ends
• MG900 with grooved ends
• MT900 in line sizes 2” to 6” NPT threaded
ends
The 900 series can be field-serviced without
the need for factory recalibration. The meter
flow tubes are coated with fusion-bonded
epoxy for maximum corrosion protection FLOW
and integral flow straightening vanes reduce
upstream flow turbulence.


FEATURES Typical Applications

Weldment/Top Plate The McCrometer propeller meter is the most
• The meter head weldment is either stainless widely used flow meter for municipal and
steel or fusion-bonded epoxy coated carbon wastewater treatment applications as well as
steel for maximum corrosion protection. agricultural and turf irrigation measurement.

• The top plate is either stainless steel (for sizes Typical applications include:
2” to 4”) or fusion-bonded epoxy coated • Water and wastewater management
carbon steel (6” and larger). As with all • Center pivot systems
McCrometer propeller flow meters, standard • Sprinkler irrigation systems
features include a magnetically coupled • Drip irrigation systems
drive, instantaneous flow rate indicator and • Golf course and park water management
straight-reading, six-digit totalizer. • Gravity turnouts from underground pipelines
Impellers • Commercial nurseries
• Impellers are manufactured of high-impact
plastic, capable of retaining their shape and
accuracy over the life of the meter. Register

• Each impeller is individually calibrated at • The instantaneous flow rate indicator is standard
the factory to accommodate the use of any and available in gallons per minute, cubic feet per
standard McCrometer register. second, liters per second and other units.
Bearings • The register is driven by a flexible steel cable
• Factory lubricated stainless steel bearings encased within a protective vinyl liner.
are used to support the impeller shaft. The • The register housing protects both the register
sealed bearing design limits the entry of and cable drive system from moisture while
materials and fluids into the bearing chamber allowing clear reading of the flow rate indicator
providing maximum bearing protection. and totalizer.





24517-23 Rev. 2.3 | 23MAR2020

Specification Sheet
MW900/MG900/MT900 Main Line Flow Meter


SPECIFICATIONS

Performance

Accuracy / ±2% of reading guaranteed throughout range. ±1% over reduced range.
Repeatability Repeatability 0.25% or better.
Range 2” to 24”

Maximum
Temperature (Standard construction) 160°F constant
Pressure Rating 150 psi


Materials
Top Plate
Weldment Stainless steel (2” to 4”) or fusion-bonded exoxy coated carbon steel (6” and larger)
Top Plate Stainless steel (2” to 4”) or fusion-bonded epoxy coated carbon steel (6” and larger)
Spool Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Body Epoxy-coated carbon steel pipe conforming to A.S.A pipe schedules
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel

Magnets (Permenant type) Alnico
Bearing Housing • For models 2” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional

Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter. High temperature impeller is optional.

Options

• Register extensions available
• All stainless steel construction
• High temperature construction
• “Over Run” bearing assembly for higher-than-normal flowrates (available only on
4” and larger)
• Electronic propeller meter available in all sizes of this model
• A complete line of flow recording/control instrumentation
• Certified calibration test results
• Stainless steel bearing housing
• Canopy boot













Page 2 24517-23 Rev. 2.3 | 23MAR2020

Specification Sheet
MW900/MG900/MT900 Main Line Flow Meter


DIMENSIONS




FLOW






NOMINAL
METER SIZE










MW900 / MG900 / MT900 DIMENSIONS
inches 2 2 1/2 3 4 6 8 10 12 14 16 18 20 24
Meter Size
mm 51 64 76 102 152 203 254 305 356 406 457 508 610
GPM 40 40 40 50 90 100 125 150 250 275 400 475 700
Minimum Flow
LPS 2.5 2.5 2.5 3.2 5.7 6.3 7.9 9.5 15.8 17.3 25.2 30.0 44.2
GPM 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500
Maximum Flow
LPS 15.8 15.8 15.8 37.9 75.7 94.6 113.6 157.7 189.3 252.4 315.5 378.5 536.3
Maximum Flow w/ GPM n/a n/a n/a 900 1800 2250 2700 3750 4500 6000 7500 9000 12750
Marathon Bearing
Approx. Head Loss in inches 29.5 29.5 29.5 23 17 6.75 3.75 2.75 2 1.75 1.5 1.25 1
Inches at Max. Flow mm 749 749 749 584 432 171 95 70 51 44 38 32 25
GPM/ 1000/ 1800/ 2500/ 3K/ 4K/ 6K/ 8K/ 10K/ 10K/ 15K/
Standard Dial Face*
Gal 100 100 100 1000 1000 1000 1000 1000 10K 10K
Approx. Shipping lbs 25 45 80 110 190 232 259 300 596 680 885
Weight, lbs. kg 11 20 36 50 86 105 117 136 270 308 401
inches 16 20 22 24 26 28 42 48 54 60 60
A
mm 406 508 559 610 660 711 1067 1219 1372 1524 1524
inches 5.25 5.25 6.25 6.25 8.25 10 13 13 14 16 18
B
mm **See special 133 133 159 159 210 254 330 330 356 406 457
inches note 5.25 5.25 6.25 6.25 8.25 10 13 13 14 16 18
C
mm 133 133 159 159 210 254 330 330 356 406 457
inches 10.5 13 14 16 19 21 21.75 24.75 25.75 28.75 32.75
D
mm 267 330 356 406 483 533 552 629 654 730 832
inches 3.5 4.5 6.5 8.5 10.75 12.75 14 16 18 20 24
H
mm 89 114 165 216 273 324 356 406 457 508 610
No. of Bolts Per Flange 6 6 6 8 8 12 12 12 12 16 16 16
* Indicates the dial face range and multiplier
** SPECIAL NOTE: Reducing ttings (female threaded), are included to adapt the 3-inch model to 2” and 2 ½” line sizes.

Larger owmeters on special order.

MT900 available in sizes 2” through 6” only.







Page 3 24517-23 Rev. 2.3 | 23MAR2020

Specification Sheet
MW900/MG900/MT900 Main Line Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1
15”
Flow



A





Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions



STRAIGHTENING VANES


Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal
sand separator. These cause swirling flow in the line that affect propeller meters. Well developed swirls can


travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.



















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-23 Rev. 2.3 | 23MAR2020

Specification Sheet
MW900/MG900/MT900 Main Line Flow Meter


TOTALIZERS

Typical face plates

2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000
500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register




Mechanical Totalizer

The instantaneous flowrate indicator is standard and available in gallons per

minute, cubic feet per second, liters per second and other units. The register is
driven by a flexible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the flowrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a flowmeter’s flowrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be fitted to any new or existing McCrometer


propeller flowmeter.





Wireless Telemetry


The optional FlowConnect is designed specifically for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze flow rate, consumption, and possible
anomalies in an irrigation system.


Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-23 Rev. 2.3 | 23MAR2020



Specification Sheet
MW800 / MM800 Right Angle Flow Meter



DESCRIPTION

Model MW800/MM800 Right Angle Meters
have a standard coating of fusion-bonded
epoxy.
These models are manufactured to comply
with the applicable provisions of the American
Water Works Association Standard No. C704-
02 for propeller type flowmeters.

As with all McCrometer propeller flowmeters,
standard features include a magnetically
coupled drive, instantaneous flowrate indicator
and straight-reading, six-digit totalizer. and FLOW
since no change gears are used, the MW800
and MM800 can be field-serviced without the
need for factory recalibration.

FEATURES

Impellers Typical Applications
• Impellers are manufactured of high-impact
plastic, capable of retaining their shape and The McCrometer propeller meter is the most
accuracy over the life of the meter. widely used flowmeter for municipal and
wastewater treatment applications as well as
• Each impeller is individually calibrated at agricultural and turf irrigation measurement.
the factory to accommodate the use of any Typical applications include:
standard McCrometer register, • Water and wastewater management
Bearings • Center pivot systems

• Factory lubricated stainless steel bearings • Sprinkler irrigation systems
are used to support the impeller shaft. • Drip irrigation systems
• Golf course and park water management
• The sealed bearing design limits the entry • Gravity turnouts from underground
of materials and fluids into the bearing pipelines
chamber providing maximum bearing • Commercial nurseries
protection.
Register

• The instantaneous flowrate indicator is
standard and available in gallons per minute,
cubic feet per second, liters per second and
other units.
• The register is driven by a flexible steel cable
encased within a protective vinyl liner.
• The register housing protects both the
register and cable drive system from
moisture while allowing clear reading of the
flowrate indicator and totalizer.






24517-22 Rev. 2.2 | 23MAR2020

Specification Sheet
MW800 / MM800 Right Angle Flow Meter


INSTALLATION

Meter may be mounted in any convenient position compatible with the balance of the system, as long as a full
pipeline is assured. Specify direction of flow when ordering. Model MW800 for up flow and model MM800 for
down flow.



SPECIFICATIONS


Performance
Accuracy /
Repeatability ±2% of reading guaranteed throughout range
Range 3” to 24”
Maximum (Standard Construction) 160°F constant
Temperature
Pressure Rating 150 psi. Consult factory for special applications.

Materials

Top Plate Stainless steel (2” to 4”) or fusion-bonded epoxy coated carbon steel (6” and larger)
Drop Pipe 304 stainless steel
Spool Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Body Epoxy-coated carbon steel pipe conforming to A.S.A pipe schedules
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel.
Magnets (Permanent type) Alnico

Bearing Housing • For models 2” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case. This
protective housing includes a domed acrylic lens and hinged cover with locking hasp.


Options
• Can be fitted with any flange standard including common international standards
• Register extensions available
• High temperature construction

• A complete line of flow recording/control instrumentation
• Certified calibration test results
• Canopy boot












Page 2 24517-22 Rev. 2.2 | 23MAR2020

Specification Sheet
MW800 / MM800 Right Angle Flow Meter


DIMENSIONS





















MW800 (UP FLOW) /
MM800 (DOWN FLOW) DIMENSIONS
Meter and Nominal 3 4 6 8 10 12 14 16 18 20 24
Pipe Size (inches)
Minimum Flow. U.S. 40 50 90 100 125 150 250 275 400 475 700
GPM
Maximum Flow U.S. 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500
GPM
Maximum Flow w/ 900 1800 2250 2700 3750 4500 6000 7500 9000 12750
Marathon Bearing

Approx. Head Loss in 29.50 23.00 17.00 6.75 3.75 2.75 2.00 1.75 1.50 1.25 1.00
Inches at Max. Flow
Standard Dial Face 800/ 1300/ 2500/ 3K/ 4K/ 6K/ 8K/
(GPM/Gal) 100 100 100 1K 1K 1K 1K
Approx. Shipping 50 87 128 182 272 370 519 601 814 976 1293
Weight- lbs.
A (inches) 22 1/2 27 7/8 29 7/8 36 3/8 42 3/8 48 3/8 54 60 66 72 1/2 84 1/2
B (inches) 5 6 1/2 8 9 11 12 14 15 16 1/2 18 22
C (inches) 12 1/4 16 5/8 18 23 28 33 38 43 48 53 1/2 63 1/2
D (inches) 6 7 1/2 9 1/2 11 3/4 14 1/4 17 18 3/4 21 1/4 22 3/4 25 29 1/2

E (inches) 7 1/2 9 11 13 1/2 16 19 21 23 1/2 25 27 1/2 32
F (inches) 3/4 3/4 7/8 7/8 1 1 1 1/8 1 1/8 1 1/4 1 1/4 1 3/8
No. of Bolts per Flange 4 8 8 8 12 12 12 16 16 20 20

Flanges in accordance with A.SA. B16.5, A.S.T.M. A181 Grade I.
Larger flowmeters on special order.
Contact the factory for MM800 (downflow) meter dimensions.











Page 3 24517-22 Rev. 2.2 | 23MAR2020

Specification Sheet
MW800 / MM800 Right Angle Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer

The instantaneous flowrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a flexible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the flowrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a flowmeter’s flowrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard

4-20mA signal. The FlowCom can be fitted to any new or existing McCrometer

propeller flowmeter.






Wireless Telemetry
The optional FlowConnect is designed specifically for wireless telemetry via either

satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility
provides data tools that can analyze flow rate, consumption, and possible

anomalies in an irrigation system.








Page 4 24517-22 Rev. 2.2 | 23MAR2020

Specification Sheet
M1700 Open Flow Flow Meter



DESCRIPTION

Model M1700 open flow meters are designed
to measure the flow in canal outlets, discharge
and inlet pipes, irrigation turnouts and other
similar installations.
The M1700 series meets or exceeds the
American Water Works Association Standard
C704-02.


FEATURES

Construction
• Constructed of stainless steel, the meter
incorporates bronze mounting brackets that
permit simple installation and removal.
Impellers
• Impellers are manufactured of high-impact
plastic, designed to retain both shape and
accuracy over the life of the meter. Typical Applications
• Each impeller is individually calibrated at the The McCrometer propeller meter is the most
factory to accommodate the use of standard widely used flowmeter for municipal water and
McCrometer registers, and since no change wastewater applications as well as agricultural
gears are necessary, the M1700 can be and turf irrigation measurements.
field-serviced without the need for factory
recalibration. Typical applications include:
Bearings • Water and wastewater management
• Canal laterals
• Factory lubricated, stainless steel bearings • Gravity turnouts from underground
are used to support the impeller shaft.
pipelines
• The sealed bearing design limits the entry • Sprinkler irrigation systems
of materials and fluids into the bearing • Golf course and park water management
chamber providing maximum bearing
protection.
• The register is driven by a flexible steel cable
Register
encased within a protective, self-lubricating vinyl
• An instantaneous flowrate indicator is liner.
standard and available in gallons per minute,
cubic feet per second, liters per second and • The die-cast aluminum register housing protects
other units. both the register and cable drive system from
moisture while allowing clear reading of the
flowrate indicator and totalizer.














24517-14 Rev. 2.1 | 23MAR2020

Specification Sheet
M1700 Open Flow Flow Meter


INSTALLATION

The M1700 must be mounted on a headwall, standpipe or other suitable structure so that the propeller is located
in the center of the discharge or inlet pipe.


PIPE RUN REQUIREMENTS

A straight run of full pipe the length of ten pipe diameters upstream and one diameter downstream of the meter
is recommended for meters without straightening vanes. Meters with optional straightening vanes require at
least five pipe diameters upstream of the meter.


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 10” to 72”
Maximum
Temperature (Standard Construction) 160°F constant
Materials

Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel
Drop Pipe 304 stainless steel construction
Bearing Housing • Impeller shaft: 316 stainless steel
• Ball bearings: 440C stainless steel
Magnets Permanent type. Alnico.
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.
Options

• Marathon bearing assembly for higher than normal flowrates 4” and larger
• Digital register available in all sizes of this model
• A complete line of flow recording/control instrumentation
• Extra wall brackets

• Canopy boot













Page 2 24517-14 Rev. 2.1 | 23MAR2020

Specification Sheet
M1700 Open Flow Flow Meter


DIMENSIONS






IMPORTANT
Open flow meters 30” and larger
require a FlowCom register.























M1700 DIMENSIONS
Meter Size (inches) 10 12 14 16 18 20 24 30 36 42 48 54 60 72
Maximum Flow U.S.
GPM 1800 2500 3000 4000 5000 6000 8500 12500 17000 22000 30000 36000 42000 60000
Minimum Flow U.S. 125 150 250 275 400 475 700 1200 1500 2200 2800 3500 4000 6000
GPM

Max. Flow w/ 2700 3750 4500 6000 7500 9000 12750 18750 25500 37500 45000 54000 63000 90000
Marathon Bearing
Approx. Head
Loss in Inches at 3.75 2.75 2.00 1.75 1.50 1.20 1.00 .52 .40 - - - - -
Maximum Flow
Standard Dial Face 3K/ 4K/ 6K/ 8K/ 10K/ 10K/ 15K/ 15K/ 30K/ 35K/
(GPM/Gal) * 1000 1000 1000 1000 1000 10K 10K 10K 10K 10K Consult factory
A * (in feet) 5 5 5 5 6 6 6 6 6 10 10 10 10 10
B Regular Brackets 2 13/16 4 3/8
(inches)
B Universal 3 15/16 -
Brackets (inches)

C (inches) 14 3/4 14 3/4 14 3/4 14 3/4 17 17 17 17 17 21 1/2 21 1/2 21 1/2 21 1/2 21 1/2
Approx. Shipping 120 120 120 120 140 140 140 140 140 250 250 250 250 250
Weight Crated - lbs.

Overall Height (ft) 5 5 5 5 6 6 6 6 6 10 10 10 10 10
* Standard lengths, optional lengths in 12” increments per customer order





Page 3 24517-14 Rev. 2.1 | 23MAR2020

Specification Sheet
M1700 Open Flow Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer

The instantaneous owrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.






Wireless Telemetry

The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 4 24517-14 Rev. 2.1 | 23MAR2020

Specification Sheet
M1104 Fire Hydrant Meter Head Assembly



DESCRIPTION

Designed for testing the flow rate of fire
hydrants, the M1104 fire hydrant flow
meter also provides totalization for use in
determining collectible revenue for temporary
hydrant deliveries.
The compact design enables the operator
to quickly and easily install the flow meter
for instantaneous and accurate flow
measurement.
The short length design and convenient
carrying handle facilitates installation,
particularly in cramped spaces.







FEATURES

• Complies with the applicable provisions Typical Applications
of AWWA Standard C704-02 and latest
revisions for propeller flowmeters
• Industrial fire control
• A lightweight and portable meter that • Marine and sprinkler system testing
provides both instantaneous flowrate
indication and totalization. • Center pivot systems
• Sprinkler irrigation systems
• Features a six-digit, straight-reading
totalizer available in U.S. gallons, cubic • Drip irrigation systems
feet and other standard units. • Golf course and park water management
• The instantaneous flowrate indicator is • Commercial nurseries
standard and available in gallons per • Water and wastewater management
minute, cubic feet per second, liter per
second and other units.
• Full 4-inch diameter stainless steel meter
tube

• Standard 2½-inch fire hydrant threads:
male threads on the outlet with a brass
swivel coupling on the inlet side
• Modular assembly for easy removal and
maintenance of major components














24517-24 Rev. 1.7 | 23MAR2020

Specification Sheet
M1104 Fire Hydrant Meter Head Assembly


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 4”
Maximum
Temperature (Standard Construction) 160°F constant
Pressure Rating 150 psi. Consult factory for higher rated version.
Materials

Flow Tube The flow tube is made of stainless steel. The impeller and bearing assembly are
suspended in the center of the tube by 304 stainless steel ell. Stator vanes located
in the inlet of the flow tube generate steady, non-rotational water flow for greater
accuracy. The swivel race and outlet threads are stainless steel for trouble-free hook
up.

Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel
Bearing Housing 304 stainless steel standard, 316 stainless steel optional
Magnets (Permanent type) Alnico
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case. This
protective housing includes a domed acrylic lens and hinged lens cover with locking
hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter. High temperature impeller is optional.
Options

• Extended warranty
• Register extensions
• All stainless steel construction
• High temperature construction
• Marathon bearing assembly for higher than normal flowrates

• A complete line of flow recording/control instrumentation
• Flow straightening vanes
• Certified calibration test results
• Canopy boot
















Page 2 24517-24 Rev. 1.7 | 23MAR2020

Specification Sheet
M1104 Fire Hydrant Meter Head Assembly


DIMENSIONS












FLOW
FLOW














M1104 DIMENSIONS
Meter and Nominal Pipe Size (inches) 4”
Minimum Flow U.S. GPM 50
Maximum Flow U.S. GPM 600
Max Flow w/ Marathon Bearing 900
Approx. Head Loss in inches at Max. Flow 60.00
Standard Dial Face (GPM/Gal) 1000/100
Approx. Shipping Weight-lbs. 20
A (inches) 15
B (inches) 16

Large flowmeters available on special order.
McCrometer reserves the right to change design or specifications without notice.




























Page 3 24517-24 Rev. 1.7 | 23MAR2020

FLANGED
INSTALLATION
Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.
PIPE RUN REQUIREMENTS
A
B
Confi guration
Without straightening vanes
1
10
5
1
With straightening vanes
1
With FS100 Flow Straightener
1.5
Flow
A 15” B
FLANGED Specification Sheet
M1104 Fire Hydrant Meter Head Assembly
INSTALLATION Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions
Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.
STRAIGHTENING VANES
PIPE RUN REQUIREMENTS
Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal


sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can
B
A
Confi guration
travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
Without straightening vanes
1
10
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
5
1
With straightening vanes
B
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.
1
1.5
With FS100 Flow Straightener
Flow
15”
A
Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions
Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener
STRAIGHTENING VANES
Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal
sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can


travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.


















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-24 Rev. 1.7 | 23MAR2020

Specification Sheet
M1104 Fire Hydrant Meter Head Assembly


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer
The instantaneous owrate indicator is standard and available in gallons per

minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.






Wireless Telemetry

The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-24 Rev. 1.7 | 23MAR2020



Propeller CONFIGURATION SHEET


MODEL L0780 REGISTER EXTENSION


DESCRIPTION APPLICATIONS

The L0780 Register Extension provides a means for Applications that would benefit from the installation of the
relocating a McCrometer Propeller Flow Meter register to a L0780 Register Extension are:
height that improves access and protection of the register.
• Flow meter locations subjected to temporary local
The L0780 Register Extension extends the register up from flooding or washdown.
the top of the flow meter to a maximum height of 120”. The • Pits and other meter locations considered enclosed
extension pipe material is 1” Schedule 80, 304 stainless spaces.
steel. The extension is provided as a kit, including drive • Meters installed below walkway level.
cable and sealing hardware. All Mc Propeller flow meters • Meters configured for higher than normal fluid
can utilize the extension. The existing meter base plate, temperatures.
register and register canopy are reused. • Electronic meters with digital registers or pulse
transmitters can also use the extension for meter
METER PERFORMANCE mounted or remote models.

Meter performance is typically unaffected by the addition of INSTALLATION
a register extension. Long extensions on small flow meters
may require a higher minimum flow rate to operate properly. The L0780 Register Extension is always mounted vertically
Maximum flow rates are unaffected. All other aspects of on horizontally installed flow meters (see figure below).
meter performance are unchanged by the extension. The Meters subjected to pipe vibration should include appropriate
stainless steel construction provides corrosion resistance anchoring of longer extensions. In areas with limited
and requires little maintenance once installed. The meter clearance over the meter, the overall height, including an
environmental protection rating of NEMA 4x is retained open canopy lid, should be considered. Orientation of the
when the installation is properly installed and maintained. register for easy viewing is accomplished when installing the
register base plate after the extension is secured in place.

APPLICATIONS

• On flow meters in enclosed spaces
• Areas subject to flooding
• Pits or areas with poor lighting
• Areas with difficult access
• Applications with higher than normal fluid temperature

ORDERING REGISTER EXTENSION


Provide the meter serial number if the extension is being in-
stalled on an existing meter.

Note any installed transmitters or electronics.
Complete the part number with the length in inches.

Example: L0780-88 = 7’4” Long Register Extension

Extensions are manufactured to the length indicated by the part
number. Pricing is by 6” increments.




3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Printed In The U.S.A. Lit. # 24517-05 Rev. 1.2/08-12
Copyright © 2008 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published technical
www.mccrometer.com data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and instructions.



Section 2







Digital Registers



Specification Sheet
FlowCom Register Models FC100 and FC101



DESCRIPTION

The FlowCom Register displays a flow meter’s
flow rate and volumetric total. The FlowCom
can be fitted to any new or existing Mc
Propeller or Water Specialties propeller flow
meter.

FEATURES

• Retrofits to any existing Mc Propeller or
Water Specialties propeller flow meter.
• Four output options: 4-20mA Loop, Open
Collector, Optically Isolated, and Contact
Closure.

• Unique Units of Measurement for Rate, Total,
4-20mA and Pulse Outputs.
• Factory sealed Remote and Meter-Mounted
Models.



SPECIFICATIONS

Environmental

Operating Temp. -4°F to 158°F (-20°C to 70°C)
Storage Temp. -4°F to 158°F (-20°C to 70°C)
Housing Rating NEMA 4X
Meter Rating (with remote mount) IP67

Input Signal

Input Compatibility McCrometer Flowmeters
Remote Distance 50 feet max.

Rate Functions

Display 5-digit
Rate Units 22 different units

Totalizer Functions
Display 8-digit
Totalizer Units 20 different units
Accuracy 0.25%
Non-Volatile Storage Updated hourly








24510-49 Rev. 1.8 | 27JUN2019

Specification Sheet
FlowCom Register Models FC100 and FC101



Programming

Program Access Magnetic wand
Access Lockout 4-digit code
Test Modes 4mA and 20mA test modes
Totalizer Reset Programming
Total Reset Disable Programming (permanent)
Calibration Adjustment + or - .01% to 10%

4-20mA Analog
Power Requirements 12 to 30VDC
Transmissions 5,000 feet max.
4mA/20mA Trim .01mA to .50mA
Engineering/Time Units 22 different units


Pulse Outputs
Engineering Units 20 different units
Optically Iso. Pulse Width 80 ms
Open Collector Pulse Width adjustable
Collector to emitter voltage 50v @ 50mA max.
Pulse Width 80 ms
Max Pulses Per Minute 150
Signal Distance 500 feet max.

Contact Closure Output

Contact Rating 30v @ 1Amp max.
Pulse Width 80 ms
Max Counts Per Minute 30
Signal Distance 500 feet

Power Requirement

Battery Type Lithium 3.6V
Battery Life 6 - 10 years
Optional 4-20mA Loop powered



















24510-49 Rev. 1.8 | 27JUN2019

Specification Sheet
FlowCom Register Models FC100 and FC101


FLOWCOM FC100 AND FC101 PART NUMBER MATRIX
CONVERSION KIT FROM MECHANICAL TO DIGITAL
Lead time for parts is ve days. For large orders contact Factory for lead time.

F C 1 0 0 -
F C 1 0 1 - __ - __ - __ - __ - __ PRICE ADDER

OUTPUT OPTIONS
No Outputs 0 0 $428
(no cable)
Open Collector $428
(7-pin or open lead cable) 0 1
4-20mA & Opto Isolated Pulse 0 2 $428
(open lead cable only)
4-20mA & Dry Contact Pulse 0 3 $428
(open lead cable only)
Telemetry Ready Open Collector $428
(7-pin to 7-pin male cable required) 0 5
Sensus w/ no pulse or 4-20mA 0 6 $75
(no pulse or 4-20mA)
Sensus w/ open collector 0 7 $75
Sensus w/ 4-20mA & Opto Isolated Pulse 0 8 $75
Sensus w/ 4-20mA & Dry Contact Pulse 0 9 $75
(no remote mount option)
CONFIGURATION
Conversion Kit K $78
Replacement R $0
REMOTE CABLE OPTIONS * (With Telemetry)
Remote Mount w/ 25ft Cable RM25 $107
Remote Mount w/ 50ft Cable RM50 $161
OUTPUT CABLE OPTIONS
OC06
Output Cable 6ft (Default Length) $0
OCT06
OC18
Output Cable 15ft $17
OCT15
Output Cable 25ft OC25 $27
OCT25
OC50
Output Cable 50ft OCT50 $54
Output Cable 75ft OC75 $80
Output Cable 100ft OC100 $107
Output Cable 125ft OC125 $134
Output Cable 150ft OC150 $161
NON-PROGRAMMABLE OPTION
Set Unit at Factory as Non-Programmable NP $0
* For telemetry cable length longer than 50 feet, contact McCrometer customer
service.













Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 3 24510-49 Rev. 1.8 | 27JUN2019



Section 3







Mc Propeller Transmitters



CONFIGURATION SHEET
EA618-02 PULSE TRANSMITTER
MODEL NON-POWERED ELECTRONIC



DESCRIPTION

The EA618-02 Non-Powered Electronic Pulse Transmitter Mc® Propeller
is a wafer-style transmitter that mounts directly below the Mechanical Register
mechanical register of any McCrometer Mc® Propeller flow
meter. Installation of the EA618-02 does not require removal
of the flow meter and can be done under flowing conditions.
The transmitter produces an output pulse frequency that is
linear with the flow rate and can be connected to McCrometer
CONNECT® remote telemetry systems or other telemetry EA618-02
systems, flow computers, digital counters, Programmable Logic Pulse Transmitter
Controllers (PLCs), and computerized data acquisition systems.
The EA618-02 requires no power source and is typically
specified for use on telemetry systems that are capable of real-
time flow. The EA618-02 is available with data logger built in
and cable security alarm options. 7-Pin Female Quick
Connect Cable
Connector
REQUIRED ORDERING INFORMATION

• The flow meter serial number when ordering for a IMPORTANT NOTE: Cable sold separately. See
McCrometer flow meter i the tables below for part numbers.
• The system the EA618 will be connected to
• The minimum pulse width specifications for the device
receiving the EA618-02 pulses CABLE OPTIONS
• Desired cable length McCrometer CONNECT Cables (Quick Connect to Quick
SPECIFICATIONS Connect)
Supply Voltage: None required Description Part Number
Output Type: 40v max open drain 15 ft., 7 pin to 7 pin cable 7M-015-7M
Max. Pulses per 25 ft., 7 pin to 7 pin cable 7M-025-7M
Output Pulse RPM's Revolution Pulse Width 50 ft., 7 pin to 7 pin cable 7M-050-7M
Duration:
1600 1 20ms Other Output Cable Options (Quick Connect To Bare
Signal 65 feet max. Lead Wires)
Distance: Description Part Number
6 ft. 7 pin to bare leads 7M-006-OE2
Additional Options
15 ft. 7 pin to bare leads 7M-015-OE2
EA618-02A EA618-02 with Cable Security Alarm
MC20-D2 EA618-02 with Data logger 25 ft. 7 pin to bare leads 7M-025-OE2
50 ft. 7 pin to bare leads 7M-050-OE2
MC20-D2 Data Logger Specifications
Max Pulse Rate 10,000Hz Open End Cable Connection
Connects To
Color
Memory 500,000 readings Yellow (-) Pulse Counter
Report rate 1/sec - 1/24 hours Gray (+) Pulse Counter
Battery life 10yrs (depends on frequency/duty cycle)
Communication IFC200 Interface USB w/ cable



3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Printed In The U.S.A. Lit. # 24527-38 Rev. 1.5 / 6-1-17
Copyright © 2012-2015 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any
published technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical
data and instructions.

SPECIFICATION SHEET

MODEL MC20-D2 MC PROPELLER DATA LOGGER





DESCRIPTION
The MC20-D2 Mc Propeller Data Logger is a wafer-style
transmitter that mounts directly below the mechanical Mc® Propeller
register of any McCrometer Mc® Propeller flow meter. Mechanical Register
Installation of the MC20-D2 does not require removal of the
flow meter and can be done under flowing conditions.

The MC20-D2 Data Logger captures pulses that are linear
with the flow rate. It stores up to 500,000 readings in the
internal memory. The data logger software saves and stores MC20-D2
downloaded data into an internal database. The software Pulse Transmitter
interface allows users to manage devices and review data,
and offers many reporting capabilities.


7-Pin Female Quick
Connect Cable
ORDERING INFORMATION Connector

You will need the flow meter serial number when ordering a McCrometer Data Logger.



i IMPORTANT NOTE: Cable and software sold separately. See the tables below for part numbers.






MC20-D2 Data Logger Specifications Additional Options
Max Pulse Rate 10,000Hz MC20-DA Data Logger communications cable
Memory 500,000 readings and software
Report rate 1/sec - 1/24 hours
Battery life 10yrs (depends on frequency/duty cycle)
Communication IFC200 Interface USB w/ cable


















3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Lit. # 30124-56, Rev. 1.0 / 6-27-18
Copyright © 2018 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published
technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data
and instructions.


Click to View FlipBook Version