COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD No. Item Description 1 Management Software • The management software shall be fully compatible with all the hardware installed 2 Access Controller • The access controller shall be complete with power supply unit, backup battery, surge protective device etc. and housed in a suitable enclosure • Minimum specification : ✓ Processor : 32-bit microchip ✓ Memory : In built for program, data and storage ✓ Card Holder Capacity : 10,000 users ✓ Event Record Capacity : 50,000 events ✓ Inputs : five (5) (door sensor, exit request, fire alarm input etc.) 3 Access Card • Minimum specification : ✓ Desfire EV1 (card serial number (CSN) read, file read and write); ✓ Mifare Classic (CSN read, sector Read and write). • Quantity of access card shall be based on projected number of staff plus 50% extra 4 Access Reader • Entry & Exit Card Reader • Specification : Comply to ISO 14443A; ISO 14443B Equipment : Management Software, Access Controller, Access Reader, Access Card, Push Button, Door Release Button, Magnetic Door Sensor, Emergency Break Glass. 351
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD No. Item Description 5 Electromagnetic Lock • The electromagnetic lock c/w mounting bracket shall • Minimum technical specifications: ✓ Holding Force : 600 lbs or 1200 lbs, as specified in bill of quantities or drawing ✓ Lock Type : Fail-safe type ✓ Power supply : 12 Vdc, 500 mA (max) 6 Magnetic Door Sensor • Minimum technical specifications: ✓ Maximum Contact Rating : 100 Vdc, 500 mA, 10 W ✓ Wide Gap up to : 25 mm wide gap closed loop 7 Emergency Break Glass • Minimum specification: ✓ Current Rating : 3A@36Vdc ✓ Output Contact : Normally closed (NC); Normally open (NO); Common (COM) 8 Backup Battery • Minimum specification: ✓ Battery : 7 AH or otherwise specified in bill of quantities or drawing ✓ Nominal Voltage : 12 Vdc ✓ Type : Rechargeable Sealed LeadAcid 352
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD No. Location Area Door Access 1. All standard wards • Main entrance (public entrance) • Staff entrance • Nurse station • Reception - Card access for entry and exit - Door release button (at nurse station/reception) 2. Operation theatre • Changing room • Transfer airlock • Nurse station (reception) - Card access for entry and exit - Door release button (at nurse station/reception) 3. Intensive care area e.g. NICU, PICU, ICU, HDW, LDR, SCN • Main entrance / visitor entrance • Staff entrance • Nurse station • Reception - Card access for entry and exit - Door release button (at nurse station/reception) 4. CSSD • Staff entrance – Staff change (dirty & clean) • Dirty receiving entrance • Sterile issuing area • Issue counter • Bulk Receiving - Card access for entry and exit - Card access for entry and push button for exit - Door release button - Door release button Hospital guideline locations and requirement 353
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD No. Location Description Note 5. Outpatient pharmacy • Staff entrance / material entrance • Drug store - Card access for entry and exit 6. Inpatient Pharmacy/Satellite Pharmacy • Main entrance (ward supply) • Issuing area • Issue counter • Dangerous Drug Room • Drug store - Entry card access and exit push button - Card access for entry and exit - Door release button - Card access for entry and exit - Card access for entry and exit 7. Medical store @ Pharmacy Logistic • Loading / unloading area • Receiving counter & office • Issue area • Issue counter • DD Room • Drug store • Fridge room - Entry card access and exit push button - Exit push button - Entry card access and exit push button - Entry card access and exit push button - Card access for entry and exit - Card access for entry and exit - Entry card access and exit push button 8. Medical Record department / admin / all departments dealing with public • Department entrance (public entrance) • Staff entrance • Medicolegal Record Room - Card access for entry and exit - Card access for entry and exit - Card access for entry and exit 354
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD Example of Door Access System Layout in 'Office Space' TAMS READER DOOR ACCESS Pintu Masuk Utama TECHNICAL DESIGN 355
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD DOOR ACCESS Example of Door Access System 'Drug Area' layout DOOR ACCESS DOOR ACCESS TECHNICAL DESIGN DOOR ACCESS 356
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD DOOR ACCESS Example of Door Access System Layout in 'Body Freezer Room' TECHNICAL DESIGN 357
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD CGSO REQUIREMENT ✓ All layout and schematic drawing for CCTV and Access Card System shall be submitted to CGSO for approval. JKR SPECIFICATION ✓ Specification For Closed Circuit Television (CCTV) System (L-S39) - Version September 2021 or Latest ✓ Specification For Electronic Access Control System (L-S29) - Version December 2018 or Latest 358
COMPONENTS OF NON-CLINICAL MATERIALS CCTV & ACCESS CARD The CCTV & Access Card System proposal document that needs to be interacted with and approved by JKR includes: • Overall layout plan - position and type of equipment • Equipment Specifications DOCUMENTS SUBMISSION 359