192 173 RG HIGH FREQUENCY COAXIAL CABLE APPLICATION : High frequency equipment, connection, internal wiring and power supply. CABLE STRUCTURE CONDUCTOR : Annealed copper (BC), Copper clad steel (CCS) or Tin INSULATION : Polyethylene (PE) or Cellular polyethylene (PEF). SHIELD : Annealed copper or Tin coated copper braid shield. SHEATH : Polyvinyl chloride (PVC) or Non - contaminating polyvinyl chloride (NC-PVC). PRODUCT CODE RG - 59 A/U (1) (2) (3) (4) 1. This symbol specifies an RG high frequency coaxial cable. 2. This indicates the high frequency coaxial cable number. 3. Sometimes there is a letter in this spot, and sometimes it is omitted. If there is a letter it indicates a change in the alphabetical sequence. 4. This letter shows that the cable is for general use. Nom inal Nom inal Nom inal Standard Im pedance Capacitance Attenuation length 100 MHz No./m m MTRL m m MTRL No./m m No./m m MTRL m m MTRL Ohm pF/km (dB/km ) m /coil RG-5/U 1/1.29 BC 4.70 LDPE 16/9/0.16 24/8/0.16 BC 8.4 ± 0.20 PVC 52.5 93.5 85 100 RG-6/U 1/1.024 CCS 4.57 LDPEF 16/9/0.16 16/8/0.16 TC 7.4 ± 0.20 PVC 75.0 56.8 69 100 RG-7/U 1/0.914 BC 6.35 LDPE 24/7/0.18 - BC 9.4 ± 0.20 PVC 94.5 41.0 66 100 RG-8/U 7/0.724 BC 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 PVC 52.0 96.8 69 100 RG-8A/U 7/0.724 BC 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 NC-PVC 52.0 96.8 69 100 RG-11/U 7/0.404 TC 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 PVC 75.0 67.3 76 100 RG-11A/U 7/0.404 TC 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 NC-PVC 75.0 67.3 76 100 RG-13/U 7/0.404 TC 7.11 LDPE 24/9/0.16 24/8/0.16 BC 10.7 ± 0.20 PVC 74.0 67.3 76 100 RG-13A/U 7/0.404 TC 7.11 LDPE 24/9/0.16 24/8/0.16 BC 10.7 ± 0.20 NC-PVC 74.0 67.3 76 100 RG-14/U 1/2.59 BC 9.40 LDPE 24/10/0.18 24/8/0.18 BC 13.8 ± 0.20 PVC 52.0 96.8 46 100 RG-14A/U 1/2.59 BC 9.40 LDPE 24/10/0.18 24/8/0.18 TC 13.8 ± 0.20 NC-PVC 52.0 96.8 46 100 RG-15/U 1/1.45 CCS 9.40 LDPE 24/10/0.18 24/8/0.18 BC 13.8 ± 0.20 PVC 76.0 65.6 49 100 RG-17/U 1/4.78 BC 17.30 LDPE 24/14/0.255 - BC 22.1 ± 0.35 PVC 52.0 96.8 28 100 RG-17A/U 1/4.78 BC 17.30 LDPE 24/14/0.255 - BC 22.1 ± 0.35 NC-PVC 52.0 96.8 28 100 RG-19/U 1/6.35 BC 23.10 LDPE 36/12/0.255 - BC 28.5 ± 0.40 PVC 52.0 96.8 22 100 RG-19A/U 1/6.35 BC 23.10 LDPE 36/12/0.255 - BC 28.5 ± 0.40 NC-PVC 52.0 96.8 22 100 RG-22/U 7/0.386X2C BC 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 PVC 95.0 52.5 118 100 RG-22A/U 7/0.386X2C BC 7.24 LDPE 24/8/0.16 24/8/0.16 BC 10.7 ± 0.20 PVC 95.0 52.5 118 100 RG-22B/U 7/0.386X2C BC 7.24 LDPE 24/8/0.16 24/8/0.16 BC 10.7 ± 0.20 NC-PVC 95.0 52.5 118 100 RG-29/U 1/0.813 BC 2.95 LDPE 16/7/0.127 - BC 4.7 ± 0.15 PE 53.5 93.5 138 100 RG-34/U 7/0.724 BC 11.60 LDPE 24/9/0.16 - BC 15.9 ± 0.25 PVC 71.0 70.5 46 100 RG-34B/U 7/0.632 BC 11.70 LDPE 24/10/0.18 - BC 16.0 ± 0.25 NC-PVC 75.0 67.0 48 100 RG-54A/U 7/0.386 BC 4.52 LDPE 16/9/0.16 - BC 6.1 ± 0.15 PE 58.0 85.8 187 100 RG-55/U 1/0.813 BC 2.90 LDPE 16/7/0.127 16/8/0.127 BC 5.0 ± 0.15 PE 53.5 93.6 138 100 RG-58/U 1/0.813 BC 2.95 LDPE 16/7/0.127 - TC 4.95 ± 0.15 PVC 53.5 93.5 138 100 RG-58A/U 19/0.18 TC 2.95 LDPEF 16/7/0.127 - TC 4.95 ± 0.15 PVC 50.0 93.5 174 100 RG-58C/U 19/0.18 TC 2.95 LDPE 16/7/0.127 - TC 4.95 ± 0.15 NC-PVC 50.0 93.5 174 100 RG-59/U 1/0.643 CCS 3.71 LDPE 16/7/0.16 - BC 6.15 ± 0.15 PVC 73.0 68.9 125 100 RG-59A/U 1/0.643 CCS 3.71 LDPE 16/7/0.16 - TC 6.15 ± 0.15 NC-PVC 73.0 68.9 125 100 RG-59B/U 1/0.584 CCS 3.71 LDPE 16/7/0.16 - BC 6.15 ± 0.15 NC-PVC 75.0 68.9 112 100 RG-62/U 1/0.643 CCS 3.71 LDPE 16/7/0.16 - BC 6.15 ± 0.15 PVC 93.0 44.3 102 100 RG-62A/U 1/0.643 CCS 3.71 LDPE 16/7/0.16 - BC 6.15 ± 0.15 NC-PVC 125.0 32.8 66 100 RG-63/U 1/0.643 CCS 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 PVC 125.0 32.8 66 100 RG-63B/U 1/0.643 CCS 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 NC-PVC 125.0 32.8 66 100 RG-71/U 1/0.643 CCS 3.71 LDPE 16/7/0.16 16/8/0.127 BC 6.4 ± 0.15 PE 93.0 44.3 102 100 RG-89/U 1/0.643 CCS 7.24 LDPE 16/12/0.18 - BC 16.0 ± 0.25 PVC 125.0 32.8 66 100 RG-108/U 7/0.32X2C TC 1.84 LDPE 16/6/0.127 - BC 6.2 ± 0.15 NC-PVC 78.0 74.3 - 100 RG-108A/U 7/0.32X2C TC 2.01 LDPE 16/6/0.127 - BC 5.97 ± 0.15 NC-PVC 78.0 74.3 - 100 RG-122/U 27/0.127 TC 2.44 LDPE 16/6/0.127 - BC 4.06 ± 0.15 NC-PVC 50.0 105.0 195 100 RG-130/U 7/0.724X2C BC 12.00 LDPE 24/8/0.255 - BC 15.9 ± 0.25 PVC 95.0 56.0 99 100 RG-133A/U 1/0.645 BC 7.20 LDPE 24/8/0.18 - BC 10.3 ± 0.20 NC-PVC 95.0 53.0 76 100 RG-164/U 1/2.65 BC 17.30 LDPE 24/14/0.255 - BC 22.1 ± 0.35 NC-PVC 75.0 67.0 30 100 RG174/U 7/0.16 CCS 1.52 LDPE 16/5/0.10 - TC 2.54 ± 0.15 NC-PVC 50.0 110.0 259 100 RG-213/U 7/0.752 BC 7.24 LDPE 24/8/0.18 - BC 10.3 ± 0.20 NC-PVC 50.0 100.0 69 100 RG-216/U 7/0.404 TC 7.24 LDPE 24/9/0.16 24/8/0.16 BC 10.8 ± 0.20 NC-PVC 75.0 67.0 88 100 RG-217/U 1/2.69 BC 9.40 LDPE 24/10/0.18 24/8/0.18 BC 13.8 ± 0.25 NC-PVC 50.0 100.0 50 100 Type Inner Braid Shield Sheath Conductor Insulation
193 174 Poly- Polyester tape propylene 100% 3 Cond. Aluminum/ 4.9 PVC - - - 100 22(7x30) Polyester tape AWG coverage w ith drain w ire Aluminum/ Cellular Polyester tape 1 Coax. Poly- 60% 6.99 PVC 75 56.7 6.9 18 ethylene 34 AWG TC or AWG Aluminum braid coverage Poly- Polyester tape propylene 100% 3 Cond. Aluminum/ 7.75 PVC - - - 22(7x30) Polyester tape AWG coverage w ith drain w ire Poly2 Cond. propylene 14(7x22) AWG CCS w hite, red 4.57 1.55 Color code : w hite, black, red 2.65 Color code : BC BC black CCS - 1.35 Color code : orange, green No. of Nominal Nominal Nominal Standard Shields Impedance Capacitance Attenuation length No./mm O.D. & O.D. 100 MHz or AWG MTRL mm MTRL Material mm MTRL Ohm pF/km (dB/100m) m/coil Aluminum/ Cellular Polyester tape Poly- 53% ethylene 34 AWG TC or Aluminum braid coverage 6.15 Aluminum/ x Cellular Polyester tape 9.60 Poly- 53% ethylene 34 AWG TC or Aluminum braid coverage Aluminum/ Cellular Polyester tape Poly- 60% ethylene 34 AWG TC or Aluminum braid coverage 6.99 Aluminum/ x Cellular Polyester tape 10.57 Poly- 60% ethylene 34 AWG TC or Aluminum braid coverage Aluminum/ Cellular Polyester tape Poly- 60% ethylene 34 AWG TC or Aluminum braid coverage 10.29 Aluminum/ x Cellular Polyester tape 13.75 Poly- 60% ethylene 34 AWG TC or Aluminum braid coverage 1/0.81 CCS 3.71 Messengered 75 56.7 8.2 100 1.3 mm. galvanized steel messenger PVC Inner Sheath Conductor Insulation 1/0.81 CCS 3.71 Type 6.15 PVC 75 8.2 100 CCS 4.57 6.99 56.7 75 56.7 6.9 100 Messengered 56.7 6.9 100 1.3 mm. galvanized steel messenger PVC 75 PVC 1/1.63 CCS 7.24 10.29 PVC 1/1.02 CCS 4.57 1/1.02 75 56.7 4.9 100 1/1.63 CCS 7.24 PVC Messengered 1.3 mm. galvanized steel messenger 75 56.7 4.9 100 SPECIAL APPLICATION MATV CABLE TVRO MULTI-PAK RG - 6/U RG - 11/U with support RG - 11/U RG - 6/U with support RG - 6/U RG - 59/U with support RG - 59/U
194
OPTICAL FIBER WIRE & CABLE OPTICAL FIBER WIRE & CABLE CONTENTS PAGE 195 OPTICAL FIBER INFORMATION 197 - Optical Specifications - Dimensional Specifications - Environmental Specifications - Mechanical Specifications - Performance Characterizations TECHNICAL CHARACTERISTICS 199 - Performance - Fiber Characteristic - Characteristic of Optical Cable SINGLE MODE OPTICAL FIBER AERIAL CABLE (A) 201 SINGLE MODE OPTICAL FIBER ARMOURED AERIAL CABLE (AA) 202 SINGLE MODE OPTICAL FIBER DUCT CABLE (D) 203 SINGLE MODE OPTICAL FIBER DIRECT BURIED CABLE (DB) 204 SINGLE MODE OPTICAL FIBER ALL-DIELECTRIC SELF-SUPPORTING CABLE (ADSS) 205 SINGLE MODE OPTICAL FIBER ANTI-RODENT ARMOURED SELF-SUPPORTING CABLE (ARSS) 206 SINGLE MODE OPTICAL FIBER FOR ACCESS SERVICE (DWT) 207 SINGLE MODE OPTICAL FIBER FOR ARMOURED ACCESS SERVICE (ADWT) 208 SINGLE MODE OPTICAL FIBER DROP CABLE ROUND TYPE FOR FTTX 209 OPTICAL FIBER SIMPLEX CABLE 210 OPTICAL FIBER DUPLEX CABLE 211 OPTICAL FIBER BREAKOUT CABLE 212 OPTICAL FIBER DISTRIBUTION CABLES 213
196
197 OPTICAL FIBER INFORMATION The optical fiber is an ITU-T Recommendation G.625.D compliant optical fiber with Corning’s enhanced low-loss and bend fiber technologies.This full-spectrum fiber has bend performance that exceeds the ITU-T Recommendation G.657.A1standard and still splices the same as the installed base of standard single-mode fibers specifications for attenuation, macrobend loss, and polarization mode dispersion values, which provide a solid foundation for new network deployments as well as upgrades to existing networks. Optical Specifications Maximum Attenuation Attenuation VS. Wavelength Macrobend Loss Point Discontinuity * Alternate attenuation offerings available upon request. ** Attenuation values at this wavelength represent post-hydrogen aging performance. The attenuation in a given wavelength range does not exceed the attenuation of the reference wavelength ( λ) by more than value α. * The induced attenuation due to fiber wrapped around a mandrel of a specified diameter. * The induced attenuation due to fiber wrapped around a mandrel of a specified diameter. Wavelength (nm) 1310 1383** 1490 1550 1625 Range (nm) 1285-1330 1525-1575 Ref. λ (nm) 1310 1550 Max. α Difference (dB/km) 0.03 0.02 Mode-Field Diameter The attenuation in a given wavelength range does not exceed the attenuation of the reference wavelength ( λ) by more than value α. Wavelength (nm) 1310 1550 MFD (µm) 9.2 +_ 0.4 10.4 +_ 0.5 Maximum Value* (db/km) < _ 0.32 < _ 0.32 < _ 0.21 < _ 0.18 < _ 0.20 Mandrel Radius (mm) 30 50 50 60 Number Of Turns 1 100 100 100 Wavelength (nm) 1550 1310 1550 1625 Induced Attenuation* (dB) < _ 0.03 < _ 0.03 < _ 0.03 < _ 0.03 Wavelength (nm) 1310 1550 Point Discontinuity (dB) < _ 0.05 < _ 0.05 Cable Cutoff Wavelength (λcc) λcc <_ 1260 nm Dispersion Polarization Mode Dispersion (PMD) Zero Dispersion Wavelength (λ0):1304 nm <_ λ0 <_ 1324 nm Zero Dispersion Slope ( s0) : <_ 0.092 ps/(nm² • km) *Complies with IEC 60794-3: 2001, Section 5.5, Method 1,(m = 20, O_ = 0.01%), September 2001. The PMD link design value is a term used to describe the PMD of concatenated lengths of fiber (also known as PMD). This value represents a statistical upper limit for total link PMD. Individual PMD values may change when fiber is cabled. Wavelength (nm) 1550 1625 PMD link Design Value Maximum Individual fiber PMD Dispersion Value [ps/(nm-km)] < _ 18.0 < _ 22.0 < _ 0.06* < _ 0.10
198 Dimensional Specifications Environmental Specifications Mechanical Specifications Performance Characterizations Glass Geometry Glass Geometry Proof test Coating Geometry Fiber Curl Cladding Diameter Core-Clad Concentricity Cladding Non-Circularity Core Diameter Numerical Aperture Effective Group Index of Refraction (Neff) Fatigue Resistance Parameter (Nd) Coating Strip Force Rayleigh Backscatter Coefficient (for 1 ns Pulse Width) Coating Diameter Coating-Cladding Concentricity > _ 4.0 m radius of curvature 125.0 +_ 0.7 µm < _ 0.5 µm < _ 0.7% 8.2 µm 0.14 NA is measured at the one percent power level of a one-dimensional far-field scan at 1310 nm. 1310 nm: 1.4676 1550 nm: 1.4682 20 Dry: 0.6 lbs. (3N) Wet, 14-day room temperature : 0.6 lbs (3N) 1310 nm: -77 dB 1550 nm: -82 dB 242 +_ 5 µm < 12 µm Environmental Test Temperature Dependence Temperature Humidity Cycling Water Immersion Heat Aging Damp Heat Test Condition -60˚C to +85˚C* -10˚C to +85˚C up to 98% RH 23˚C +_ 2˚C 85˚C +_ 2˚C 85˚C at 85% RH Induced Attenuation 1310 nm, 1550 nm, and 1625 nm (db /km) < _ 0.05 < _ 0.05 < _ 0.05 < _ 0.05 < _ 0.05 *Reference temperature = +23˚C Operating Temperature Range: -60˚C to +85˚C The entire fiber length is subjected to a tensile stress > _ 100 kpsi (0.69 GPa).* *Higher prooftest levels available Characterized parameters are typical values.
199 ♦ Low loss, low dispersion ♦ Proper design and precise excess length control and cabling process offers cable superior mechanical and environmental properties ♦ Applicable to long distance, inter-exchange communication, CATV, computer network transmission system, etc. ♦ Minimum bend radius: static 10D, Dynamic 20D ♦ Operation temperature: -10 to +70 Performance Cable Specification Fiber color code Fiber characteristic All characteristics of the cable fiber (fiber of finished cable) shall be, at least, in accordance with the ITU-T RecommendationG.657A / G.652D / G.655 Cable structure and parameter TECHNICAL CHARACTERISTICS No. Color No. Color No. Color No. Color 1 Blue 7 Red 13 Blue+BK* 19 Red+BK 2 Orange 8 Black 14 Orange+BK 20 Natural+BK 3 Green 9 Yellow 15 Green+BK 21 Yellow+BK 4 Brown 10 Violet 16 Brown+BK 22 Violet+BK 5 Gray 11 Pink 17 Gray+BK 23 Pink+BK 6 White 12 Aqua 18 White+BK 24 Aqua+BK Messenger strand steel wire diameter No. / mm 7 / 1.32 7 / 1.32 Tube Diameter mm 2.0 2.4 Fiber number 12 24 Sheath thickness (nominal*) mm 1.5 1.5 Weight (Approx.) kg/km 116 125 Diameter W*H (Nominal*) mm 7.3*14.3 7.9*14.9 * BK = Black
200 Characteristic of Optical Cable 4.1 Cable bending radius: 10 x cable diameter (during operation) 20 x cable diameter (during installation) 4.2 Temperature range Operating temperature range Storage / Transport temperature range Installation temperature range - 10˚C to + 70˚C- -10˚C to +70˚C ~ 32˚C 4.3 Main mechanical & environmental characteristics tes 1 Tensile Strength 2 Crush Test 3 Impact Test 4 Repeated Bending 5 Torsion 6 Water Penetration 7 Temperature Cycling As per IEC 60794-1-2-E1 As per IEC 60794-1-2-E3 As per IEC 60794-1-2-E4 As pe IEC 60794-1-2-E6. As pe IEC 60794-1-2-E7 As pe IEC 60794-1-2-F5B As pe IEC 60794-1-2-F1
201 SINGLE MODE OPTICAL FIBER AERIAL CABLE ( A ) TIS 2166-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 12 Fibers up to 312 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn , Ripcord : Polyester ripcord Support strand : Galvanized steel strand Sheath : Black High Density Polyethylene (HDPE) Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2166 - 2548 : ITU-T Recommendation G.652.D For primarily use in outdoor cable plant network, aerial installation by using the support messenger Number of fiber 12 24 36 48 60 72 84 96 108 120 144 216 240 264 288 312 Number of tube 2 4 3 4 5 6 7 8 9 10 12 18 20 22 24 26 Max. number of tube 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Overall diameter ( mm.) 20.0 20.0 20.0 20.0 20.0 22.5 22.5 22.5 22.5 25.5 25.5 25.5 30.0 30.0 30.0 30.0 Max. pull force ( N.) 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 Cable weight approx. ( Kg./Km. ) 195 195 195 195 195 290 290 290 290 345 345 345 490 490 490 490 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER AERIAL CABLE ( A ) TIS 2166-2548 OPTICAL FIBER
202 SINGLE MODE OPTICAL FIBER ARMOURED AERIAL CABLE ( AA ) TIS 2166-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 12 Fibers up to 312 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn Inner sheath : Black Polyethylene ( PE ) Ripcord : Polyester ripcord and Aramid ripcord Armour : Steel tape ( EGE tape ) Support strand : Galvanized steel strand Sheath : Black High Density Polyethylene ( HDPE ) Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2166 - 2548 : ITU-T Recommendation G.652.D For primarily use in outdoor cable plant network, aerial installation by using the support messenger and shall be applied to relief the cable deteriorations which result from wildfire , squirrel , rodent etc. Number of fiber 12 24 36 48 60 72 84 96 108 120 144 216 240 264 288 312 Number of tube 2 4 3 4 5 6 7 8 9 10 12 18 20 22 24 26 Max. number of tube 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Overall diameter ( mm.) 23.0 23.0 23.0 23.0 23.0 25.5 25.5 25.5 25.5 28.5 28.5 28.5 33.5 33.5 33.5 33.5 Max. pull force ( N.) 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 Cable weight approx. ( Kg./Km. ) 300 300 300 300 300 420 420 420 420 510 510 510 670 670 670 670 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER ARMOURED AERIAL CABLE ( AA ) TIS 216OPTICAL FIBER
203 SINGLE MODE OPTICAL FIBER DUCT CABLE ( D ) TIS 2165-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 12 Fibers up to 312 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn , Additional strength : E-Glass yarn or Aramid yarn (if requirement ) Ripcord : Polyester ripcord or Aramid ripcord Moisture barrier sheath : Plastic coated aluminium tape Sheath : Black High Density Polyethylene ( HDPE ) Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2165 - 2548 : ITU-T Recommendation G.652.D For primarily use in outdoor cable plant network ,underground installation in duct Number of fiber 12 24 36 48 60 72 84 96 108 120 144 216 240 264 288 312 Number of tube 2 4 3 4 5 6 7 8 9 10 12 18 20 22 24 26 Max. number of tube 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Overall diameter ( mm.) 12.0 12.0 12.0 12.0 12.0 14.1 14.1 14.1 14.1 16.5 16.5 16.5 20.5 20.5 20.5 20.5 Max. pull force ( N.) 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 Cable weight approx. ( Kg./Km. ) 300 300 300 300 300 420 420 420 420 510 510 510 670 670 670 670 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER DUCT CABLE ( D ) TIS 2165-2548 OPTICAL FIBER
204 SINGLE MODE OPTICAL FIBER DIRECT BURIED CABLE ( DB ) TIS 2165-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 12 Fibers up to 312 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn , Additional strength : E-Glass yarn or Aramid yarn (if requirement ) Ripcord : Polyester ripcord or Aramid ripcord Moisture barrier sheath : Plastic coated aluminium tape Inner sheath : Black Polyethylene ( PE ) Armour : Steel tape ( EGE tape ) Sheath : Black High Density Polyethylene ( HDPE ) Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2165 - 2548 : ITU-T Recommendation G.652.D For primarily use in outdoor cable plant network, installation direct buried to underground and shall be applied to relief the cable deteriorations which result from wildfire, squirrel, rodent etc. Number of fiber 12 24 36 48 60 72 84 96 108 120 144 216 240 264 288 312 Number of tube 2 4 3 4 5 6 7 8 9 10 12 18 20 22 24 26 Max. number of tube 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Overall diameter ( mm.) 16.9 16.9 16.9 16.9 16.9 17.0 17.6 18.3 18.8 19.5 21.0 21.7 22.4 23.1 23.8 24.6 Max. pull force ( N.) 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 Cable weight approx. ( Kg./Km. ) 260 260 265 265 265 265 290 310 325 345 400 410 440 465 490 520 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER DIRECT BURIED CABLE ( DB ) TIS 2165-2548 OPTICAL FIBER
205 SINGLE MODE OPTICAL FIBER All-DIELECTRIC SELF-SUPPORTING CABLE ( ADSS ) TIS 2166-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 12 Fibers up to 312 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn Additional strength : E-Glass yarn or Aramid yarn (if requirement ) Ripcord : Polyester ripcord Sheath : Black High Density Polyethylene ( HDPE ), FR PE or LSZH Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2166 - 2548 : ITU-T Recommendation G.652.D For primarily use in outdoor cable plant network ,for aerial application installation or indoor installation and shall be applied to relief the cable. Number of fiber 12 24 36 48 60 72 84 96 108 120 144 216 240 264 288 312 Number of tube 2 4 3 4 5 6 7 8 9 10 12 18 20 22 24 26 Max. number of tube 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Overall diameter ( mm.) 11.0 11.0 11.0 11.0 11.0 14.0 14.0 14.0 14.5 14.5 14.5 16.5 20.5 20.5 20.5 20.5 Max. pull force ( N.) 1,800 1,800 1,800 1,800 1,800 2,500 2,500 2,500 2,500 2,500 3,000 3,000 3,000 3,000 3,000 3,000 Cable weight approx. ( Kg./Km. ) 95 95 95 95 95 120 120 120 140 140 143 275 295 295 295 295 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER All-DIELECTRIC SELF-SUPPORTING CABLE ( ADSS ) TIS 2166-2548 OPTICAL FIBER
206 SINGLE MODE OPTICAL FIBER ANTI-RODENT ARMOURED SELF-SUPPORTING CABLE ( ARSS ) TIS 2166-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 12 Fibers up to 312 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn Additional strength : E-Glass yarn or Aramid yarn (if requirement) Ripcord : Polyester ripcord or Aramid ripcord Armour : Steel tape ( EGE tape ) Sheath : Black High Density Polyethylene ( HDPE ), FR PE or LSZH Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2166 - 2548 : ITU-T Recommendation G.652.D For primarily use in outdoor cable plant network for aerial application or indoor installation and shall be applied to relief the cable deteriorations which result from wildfire , squirrel , rodent etc. Number of fiber 12 24 36 48 60 72 84 96 108 120 144 216 240 264 288 312 Number of tube 2 4 3 4 5 6 7 8 9 10 12 18 20 22 24 26 Max. number of tube 6 6 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Overall diameter ( mm.) 11.0 11.0 11.0 11.0 11.0 14.0 14.0 14.0 14.5 14.5 14.5 16.5 20.5 20.5 20.5 20.5 Max. pull force ( N.) 1,800 1,800 1,800 1,800 1,800 2,500 2,500 2,500 2,500 2,500 3,000 3,000 3,000 3,000 3,000 3,000 Cable weight approx. ( Kg./Km. ) 95 95 95 95 95 120 120 120 140 140 143 275 295 295 295 295 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER ANTI-RODENT ARMOURED SELF-SUPPORTING CABLE ( ARSS ) TIS 2166-254OPTICAL FIBER
207 SINGLE MODE OPTICAL FIBER CABLE FOR ACCESS SERVICE ( DWT ) TIS 2166-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 2 Fibers up to 12 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP ( if requirement ) Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn , Ripcord : Polyester ripcord Support wire : Galvanized steel wire Sheath : Black High Density Polyethylene ( HDPE ) Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2166 - 2548 : ITU-T Recommendation G.652.D For primarily or access use in outdoor cable plant network, aerial installation by using the support messenger Number of fiber 2 4 6 8 12 Number of tube 1 1 1 2 2 Max. number of tube 2 4 6 4 6 Overall diameter ( mm.) 12.3 12.3 12.3 12.3 12.3 Max. pull force ( N.) 1,000 1,000 1,000 1,000 1,000 Cable weight approx. ( Kg./Km. ) 70 70 70 75 75 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER CABLE FOR ACCESS SERVICE ( DWT ) TIS 2166OPTICAL FIBER
208 SINGLE MODE OPTICAL FIBER CABLE FOR ARMOURED ACCESS SERVICE ( ADWT ) TIS 2166-2548 CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 2 Fibers up to 12 Fibers Buffer Tube : Polybutylene terephthalate ( PBT ) and gel-filled ( Thixotropic compound ) Core Identification : EIA/TIA -598-A Strength member : FRP ( if requirement ) Lay Up : Reverse Oscillating Lay ( ROL ) Technique ( SZ direction ) Swellable materials : Water blocking Tape and yarn , Ripcord : Polyester ripcord or Aramid ripcord Armour : Steel tape ( EGE tape ) Support wire : Galvanized steel wire Sheath : Black High Density Polyethylene ( HDPE ) Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : TIS 2166 - 2548 : ITU-T Recommendation G.652.D For primarily or access use in outdoor cable plant network, aerial installation by using the support messenger and shall be applied to relief the cable deteriorations which result from wildfire, squirrel, rodent etc Number of fiber 2 4 6 8 12 Number of tube 1 1 1 2 2 Max. number of tube 2 4 6 4 6 Overall diameter ( mm.) 12.5 12.5 12.5 12.5 12.5 Max. pull force ( N.) 1,800 1,800 1,800 1,800 1,800 Cable weight approx. ( Kg./Km. ) 110 110 110 110 110 Standard length ( m. ) 4,000/R 4,000/R 4,000/R 4,000/R 4,000/R R : Packing in Reel ARMOURED SINGLE MODE OPTICAL FIBER CABLE FOR ACCESS SERVICE ( ADWT ) TIS 216OPTICAL FIBER
209 SINGLE MODE OPTICAL FIBER DROP CABLE ROUND TYPE FOR FTTX CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 1 Fiber up to 8 Fibers Tight Buffer : PBT, TPE , PA, PVC Core Identification : EIA/TIA -598-A Strength member : Aramid yarn Support strand : Galvanized steel wire strand Sheath : FR-PE , or LSZH Optical Fiber : Single Mode Temperature installation operation : -10°C to 70°C Reference standard : ITU-T Recommendation G.652.D or ITU-T Recommendation G.657A or G657A1 For primarily or access use in outdoor cable plant network, aerial installation by using the support messenger for the last link in the optical network ( FTTX ) which terminates the fiber from the optical terminal closure or distribution point Number of fiber 1 2 4 6 8 Number of tube 3.5 3.5 5.5 5.5 6.0 Max. number of tube 6.7 6.7 9.1 9.1 10.8 Overall diameter ( mm.) 12.5 12.5 12.5 12.5 12.5 Max. pull force ( N.) 800 800 800 800 800 Cable weight approx. ( Kg./Km. ) 23 23 42 45 50 Standard length ( m. ) 1,000/R 1,000/R 1,000/R 1,000/R 1,000/R R : Packing in Reel SINGLE MODE OPTICAL FIBER DROP CABLE ROUND TYPE FOR FTTX OPTICAL FIBER
210 OPTICAL FIBER SIMPLEX CABLE CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 1 Fiber Tight Buffer : PBT, TPE , PA, PVC Core Identification : EIA/TIA -598-A Strength member : Aramid yarn Jacket : FR-PE , or LSZH , or PVC Jacket color : Yellow for singlemode , Orange for multimode and other colors possible Optical Fiber : Singlemode or Multimode Temperature installation operation : -10°C to 70°C Reference standard : ITU-T Recommendation G.652.D or ITU-T Recommendation G.657A or G657A1 For use as a path cable in distribution systems as well as for connecting terminals due to the high exibility and small diameter Cable diameter ( mm.) 1.6 1.8 2.0 2.1 2.4 2.8 2.9 3.0 3.4 Max. pull force ( N.) 200 200 300 300 400 400 400 400 400 Max. crush (N/dm) 100 100 100 100 150 150 150 150 150 Cable weight approx. ( Kg./Km. ) 2.9 3.7 5.0 5.1 5.7 7.9 8.0 8.1 12.0 Min. bending radius static (mm.) 30 30 30 30 30 30 30 30 30 Standard length ( m. ) 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R R : Packing in Reel OPTICAL FIBER SIMPLEX CABLE JACKET ARAMID YARN OPTICAL FIBER TIGHT BUFFER
211 OPTICAL FIBER DUPLEX CABLE CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 2 Fibers Tight Buffer : PBT, TPE , PA, PVC Core Identification : EIA/TIA -598-A Strength member : Aramid yarn Jacket : FR-PE , or LSZH , or PVC Jacket color : Yellow for singlemode, Orange for multimode and other colors possible Optical Fiber : Singlemode or Multimode Temperature installation operation : -10°C to 70°C Reference standard : ITU-T Recommendation G.652.D or ITU-T Recommendation G.657A or G657A1 For use as a path cable in distribution systems as well as for connecting terminals due to the high exibility and small diameter Cable diameter ( mm.) 1.6x3.3 1.8x3.7 2.0x4.1 2.1x4.3 2.4x4.9 2.8x5.7 3.0x6.1 Max. pull force ( N.) 400 400 400 400 400 600 600 Max. crush (N/dm) 200 200 200 400 400 600 600 Cable weight approx. ( Kg./Km. ) 5.8 7.4 9.0 9.0 12.6 15.8 17.5 Min. bending radius static (mm.) 30 30 30 30 30 30 30 Standard length ( m. ) 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R R : Packing in Reel OPTICAL FIBER DUPLEX CABLE JACKET OPTICAL FIBER ARAMID YARM TIGHT BUFFER TIGHT BUFFER
212 OPTICAL FIBER BREAKOUT CABLE CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 2 Fibers Tight Buffer : PBT, TPE , PA, PVC Core Identification : EIA/TIA -598-A Strength member : Aramid yarn Jacket : FR-PE , or LSZH , or PVC Jacket color : Yellow for singlemode , Orange for multimode and other colors possible Optical Fiber : Singlemode or Multimode Temperature installation operation : -10°C to 70°C Reference standard : ITU-T Recommendation G.652.D or ITU-T Recommendation G.657A or G657A1 For indoor use as a path cable in distribution systems as well as for connecting terminals or direct connector assembly and installation in the rising and horizontal. Number of Fibers 2 4 6 8 10 12 16 Cable diameter (mm.) 6.0 6.0 6.9 8.3 9.9 11.0 10.7 Max. pull force ( N.) 600 600 800 800 800 800 1,000 Max. crush (N/dm) 800 800 800 800 800 800 800 Cable weight approx. ( Kg./Km. ) 35 35 47 69 105 119 106 Standard length ( m. ) 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R R : Packing in Reel OPTICAL FIBER BREAKOUT CABLE STRENGTH MEMBER SIMPLEX CABLE OPTICAL FIBER JACKET
213 Sub -Unit OD. (mm.) N/A N/A N/A N/A N/A N/A N/A N/A 4.5 4.5 5.5 5.5 5.5 5.5 5.5 OPTICAL FIBER DISTRIBUTION CABLES CABLE STRUCTURE TECHNICAL DATA APPLICATION Optical Fiber : Size 2 - 144 Fibers Tight Buffer : PBT, TPE , PA, PVC Core Identification : EIA/TIA -598-A Additional Strength : Aramid yarn Strength Member : FRP (if requirement) Moisture Resistant : Water Blocking Tape and Yarn ( if requirement ) Jacket : FR-PE , or LSZH , or PVC Jacket color : Black or customer’s requirement Optical Fiber : Singlemode or Multimode Temperature installation operation : -10°C to 70°C Reference standard : ITU-T Recommendation G.652.D or ITU-T Recommendation G.657A or G655 For indoor and outdoor distribution systems in -Building backbone, factory floor automation, data center EDA areas and installation in the rising and horizontal. Number of Fibers 2 4 6 8 10 12 16 24 24 ( 6 F/Sub- units ) 36 ( 6 F/Sub- units ) 36 ( 12 F/Sub- units ) 48 ( 12 F/Sub- units ) 72 ( 12 F/Sub- units ) 96 ( 12 F/Sub- units ) 144 ( 12 F/Sub- units ) Cable Diameter (mm.) 4.8 4.8 4.8 5.8 5.8 5.8 8.8 8.8 13.1 16.0 14.1 15.5 19.0 22.8 25.4 Max. pull force ( N.) 550 550 550 660 660 660 1,000 1,000 2,000 3,300 2,000 2,800 4,200 5,500 8,400 Cable weight approx. ( Kg./Km. ) 22 25 31 36 39 43 64 80 145 221 162 207 321 536 602 Standard length ( m. ) 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R 300,500/R R : Packing in Reel OPTICAL FIBER DISTRIBUTION CABLES WATER BLOCKING TAPE JACKET TIGHT BUFFER FRP OPTICAL FIBER ARAMID YARN SUB‐UNIT WATER BLOCKING TAPE JACKET TIGHT BUFFER FRP OPTICAL FIBER ARAMID YARN SUB‐UNIT
214
215 ENAMELLED COPPER WIRES CONTENTS PAGE PRODUCTS PROPERTIES AND APPLICATIONS 215 DIMENSIONS OF ENAMELLED COPPER WIRE 216 DIMENSIONS OF BOBBINS AND STANDARD NET WEIGHT 217 215
216
176 217 UEW 130 POLYURETHANE WIRE IEC317.4 POLYURETHANE (B) 130°C FDD,HDD,TOY,A.V.Apparatus Solderability Adherence Lubricating oil TIS 174 - 2525 Electric tranformer TV&Display Benzol resistance Nylon coat JIS C3202 Flyback Trans,Relay coil, Timer coil Alcohol resistance High frequency coil PEW 155 POLYESTER WIRE IEC 317.3 MODIFIED POLYESTER (F) 155°C fan motors, household motors Adherence Lubricating oil TIS 226 - 2525 automobile motors & generators Acid resistance Nylon coat JIS C3202 TYPE TRADE NAME PRODUCTS PROPERTIES AND APPLICATIONS : REFERENCE STANDARDS ENAMEL BASE COAT TOP THERMAL CLASS IEC 317 TYPICAL APPLICATION SPECIAL PROPERTIES LUBRICATING
218 177 CONDUCTOR DIAMETER TOLERANCE MIN.FILM MAX.OVERALL MIN.FILM MAX.OVERALL MIN.FILM MAX.OVERALL MAX. RESISTANCE ± THICKNESS DIAMETER THICKNESS DIAMETER THICKNESS DIAMETER AT 20°c mm. mm. mm. mm. mm. mm. mm. mm. Ω/km. 0.55 0.020 0.025 0.646 0.017 0.620 0.012 0.592 74.18 0.50 0.010 0.025 0.586 0.017 0.560 0.012 0.542 89.95 0.45 0.010 0.024 0.532 0.016 0.508 0.011 0.490 112.10 0.40 0.010 0.023 0.480 0.015 0.456 0.011 0.439 141.70 0.37 0.010 0.022 0.446 0.014 0.424 0.010 0.407 165.90 0.35 0.010 0.021 0.424 0.014 0.402 0.010 0.387 185.70 0.32 0.010 0.021 0.394 0.014 0.372 0.010 0.357 222.80 0.30 0.010 0.021 0.374 0.014 0.352 0.010 0.337 254.00 0.29 0.010 0.020 0.360 0.013 0.340 0.009 0.324 273.90 0.28 0.010 0.020 0.350 0.013 0.330 0.009 0.314 294.10 0.27 0.010 0.020 0.340 0.013 0.320 0.009 0.304 316.60 0.26 0.010 0.020 0.330 0.013 0.310 0.009 0.294 341.80 0.25 0.008 0.020 0.318 0.013 0.298 0.009 0.284 370.20 0.24 0.008 0.020 0.308 0.013 0.288 0.009 0.274 402.20 0.23 0.008 0.020 0.298 0.013 0.278 0.009 0.264 438.60 0.22 0.008 0.019 0.286 0.012 0.266 0.008 0.252 480.10 0.21 0.008 0.019 0.276 0.012 0.256 0.008 0.241 522.80 0.20 0.008 0.019 0.266 0.012 0.246 0.008 0.231 577.20 0.19 0.008 0.019 0.256 0.012 0.236 0.008 0.221 640.60 0.18 0.008 0.019 0.246 0.012 0.226 0.008 0.211 715.00 0.17 0.008 0.018 0.232 0.011 0.214 0.007 0.199 787.10 0.16 0.008 0.018 0.222 0.011 0.204 0.007 0.189 890.60 0.15 0.008 0.017 0.210 0.010 0.192 0.006 0.177 1016.00 DIMENSIONS OF ENAMELLED COPPER WIRE CONDUCTOR CLASS 0 CLASS 1 CLASS 2
219 178 Inside Flange Bore Spool Standard Width Thickness Diameter Net Net (mm) (mm) (mm) Weight Weight W a h g kg PL-1 80 ± 0.5 - 50 ± 0.3 - 100 ± 0.3 10 ± 0.2 20 ± 80 ± 2 1.0 PL-2 100 ± 0.5 - 65 ± 0.5 - 125 ± 0.3 10 ± 0.2 20 ± 160 ± 3 2.0 PL-3 120 ± 0.5 - 76 ± 0.5 - 130 ± 0.4 10 ± 0.2 20 ± 220 ± 3 3.0 PL-4 125 ± 0.5 - 80 ± 0.5 - 160 ± 0.4 15 ± 0.2 25 ± 240 ± 5 4.0 PL-4S 135 ± 0.5 - 80 ± 0.5 - 110 ± 0.4 32.5 ± 0.5 20 ± 314 ± 5 4.0 PL-8 160 ± 0.5 - 100 ± 0.5 - 200 ± 15 ± 0.2 30 ± 555 ± 5 8.0 PL-1S 80 ± 0.5 - 50 ± 0.3 - 92 ± 1.5 28 ± 1.5 20 ± 80 ± 2 1.0 PL-400S 76 ± 0.1 - 60 ± 0.1 - 68 ± 0.1 12 ± 0.1 16 ± 98 ± 0.5 0.4 PL-600S 88 ± 0.1 - 68 ± 0.1 - 79 ± 0.1 14 ± 0.1 16 ± 136 ± 0.5 0.6 PT-1 105 ± 0.5 95 ± 0.5 58 ± 0.3 53 ± 0.3 100 ± 0.3 10 ± 0.2 20 ± 140 ± 3 1.5 PT-2 115 ± 0.5 105 ± 0.5 67 ± 0.3 60 ± 0.3 150 ± 0.3 10 ± 0.2 20 ± 170 ± 3 2.5 PT-4 140 ± 0.5 124 ± 0.5 86 ± 0.5 74 ± 0.5 170 ± 0.4 15 ± 0.2 26 ± 340 ± 5 4.0 PT-10 180 ± 0.5 160 ± 0.5 110 ± 0.5 96 ± 0.5 200 ± 0.4 15 ± 0.2 26 ± 620 ± 5 10.0 PT-15 200 ± 0.5 180 ± 0.5 110 ± 0.5 96 ± 0.5 200 ± 0.4 15 ± 0.2 30 ± 740 ± 10 15.0 PT-25 230 ± 0.5 215 ± 0.5 130 ± 0.5 110 ± 0.5 250 ± 0.4 15 ± 0.2 30 ± 1000 ± 15 25.0 PT-60 300 ± 0.8 270 ± 0.8 180 ± 0.8 150 ± 0.8 350 ± 1.0 25 ± 0.3 45 ± 2400 ± 30 60.0 PT-90 315 ± 1.0 300 ± 1.0 200 ± 1.0 180 ± 1.0 425 ± 1.5 38 ± 1.0 100 ± 3900 ± 30 90.0 Spool No. DIMENSIONS OF BOBBINS AND STANDARD NET WEIGHT FOR ENAMELLED COPPER WIRE Flange Diameter (mm) Barrel Diameter (mm) D1 D2 d1 d2 B O B B I N 0.5 0 0.5 0 0.5 0 0.5 0 0.5 0.5 0 0.3 0 0.1 0.1 0.5 0 0.5 0 0.5 0 0.5 0 0.5 0 0.5 0 0.5 0 1.0 0
220