92 Conductor :Concentric Stranded and compacted round Classification : Maximum conductor temperature 900 C annealed copper : Circuit voltage not exceeding 1,200 Volts Single Core : Size 1.5 mm2 up to 1,000 mm2 Reted voltage (Uѿ/U) 0.6/1 kV Multi-cores : Size 1.5 mm2 up to 400 mm2 600 Volts between Line-to-Earth Insulation :Cross-linked Polyethylene (XLPE) 1,000 Volts between Line-to-Line Core identification Testing voltage : 3,500 Volts Single-core :Natural (Translucent) Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1 2 Cores :Blue and Brown IEC 60332-3-24 (Cat.C) ,TIS 2143-2546 3 Cores :Brown, Black and Grey 4 Cores :Blue, Brown, Black and Grey Use for installation exposed or in raceway Other colors are available on customer request or direct burial in ground, at wet or dry location. Sheath :Black Flame Retardant polyvinyl chloride (PVC/ST2) Number Nominal Number Insulation Sheath Overall Conductor Insulation Continuous Cable Standard of corss of thickness thickness diameter resistance resistance current weight length core sectional wires nominal nominal approx. at 20϶ C at 20϶ C rating in approx. area minimum maximum minimum free air maximum (mm²) (No./mm) (mm) (mm) (mm) (ё/km) (MёͲkm) (A) (kg/km) (m) 1.5 7/0.53 0.7 1.8 12.0 12.1 2,500 22 180 500/D 2.5 7/0.67 0.7 1.8 13.5 7.41 2,100 29 230 500/D 4 7/0.85 0.7 1.8 14.5 4.61 1,700 39 300 500/D 6 7/1.04 0.7 1.8 16.0 3.08 1,450 49 400 500/D 10 6 0.7 1.8 17.5 1.83 1,250 66 550 500/D 16 6 0.7 1.8 20 1.15 1,000 88 800 500/D 25 6 0.9 1.8 24 0.727 1,050 118 1,200 500/D 35 6 0.9 1.8 27 0.524 900 145 1,600 500/D 50 6 1.0 1.9 30 0.387 850 176 2,200 500/D 70 12 1.1 2.0 35 0.268 800 222 3,000 500/D 95 15 1.1 2.1 39 0.193 700 272 4,100 500/D 120 18 1.2 2.3 44 0.153 700 320 5,000 500/D 150 18 1.4 2.4 49 0.124 700 366 6,500 500/D 185 30 1.6 2.6 54 0.0991 700 422 8,000 300/D 240 34 1.7 2.8 61 0.0754 650 498 10,500 300/D 300 34 1.8 3.0 68 0.0601 600 567 13,000 200/D 400 53 2.0 3.3 76 0.0470 600 652 16,500 200/D 4 D: Packing in drum 0.6/1 KV-CV-FD CABLE STRUCTURE TECHNICAL DATA APPLICATION TIS 2143-2546, IEC 60502-1 0.6/1 kV 90϶ C CROSSͲLINKED POLYETHYLENE INSULATED PVC SHEATHED FLAME RETARDANT POWER CABLE CONDUCTOR INSULATION BINDING TAPE FILLERS SHEATH
93 77 TIS 2143-2546, IEC 60502-1 TIS 2143-2546 INNER SHEATH CONDUCTOR INSULATION SEPARATOR TAPE ARMOR OUTER SHEATH BINDING TAPE FILLERS
7894 TIS 2143-2546, IEC 60502-1 TIS 2143-2546 INNER SHEATH CONDUCTOR INSULATION SEPARATOR TAPE ARMOR OUTER SHEATH BINDING TAPE FILLERS
7995 TIS 2143-2546, IEC 60502-1 TIS 2143-2546 INNER SHEATH CONDUCTOR INSULATION SEPARATOR TAPE ARMOR OUTER SHEATH BINDING TAPE FILLERS
96
COPPER CONDUCTOR CABLES HIGH & MEDIUM VOLTAGE POWER CABLES COPPER CONDUCTOR CABLES HIGH AND MEDIUM VOLTAGE POWER CABLES CONTENTS PAGE 97 1.8/3KV-CV 1.8/3(3.6) kV 90o C CROSS-LINKED POLYETHYLENE INSULATED 99 AND PVC SHEATHED POWER CABLE (TIS 2143-2546, IEC 60502-1) 3.6/6KV-CV 3.6/6(7.2) kV 90o C CROSS-LINKED POLYETHYLENE INSULATED 101 AND PVC SHEATHED POWER CABLE (TIS 2143-2546, IEC 60502-2) 6/10KV-CV 6/10(12) kV 90o C CROSS-LINKED POLYETHYLENE INSULATED 103 AND PVC SHEATHED POWER CABLE (TIS 2143-2546, IEC 60502-2) 8.7/15KV-CV 8.7/15(17.5) kV 90o C CROSS-LINKED POLEYTHYLENE INSULATED 105 AND PVC SHEATHED POWER CABLE (TIS 2143-2546, IEC 60502-2) 12/20KV-CV 12/20(24) kV 90o C CROSS-LINKED POLYETHYLENE INSULATED 107 AND PVC SHEATHED POWER CABLE (TIS 2143-2546, IEC 60502-2) 18/30KV-CV 18/30(36) kV 90o C CROSS-LINKED POLYETHYLENE INSULATED 109 AND PVC SHEATHED POWER CABLE (TIS 2143-2546, IEC 60502-2) 69 kV - CE 69 kV 90°C CROSS LINKED POLYETHYLENE INSULATED WITH 111 COPPER WIRE SCREEN AND POLYETHYLENE SHEATH POWER CABLE (TIS 2202-2547, IEC 60840) 115 kV - CE 115 kV 90°C CROSS LINKED POLYETHYLENE INSULATED WITH 112 COPPER WIRE SCREEN AND POLYETHYLENE SHEATH POWER CABLE (TIS 2202-2547, IEC 60840)
98
99 INSULATION SHIELD TAPE CONDUCTOR SEPARATOR TAPE INSULATION SHEATH CONDUCTOR COVERING TAPE COPPER SHIELD TAPE : Copper tape : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
100 CONDUCTOR INSULATION SEPARATOR TAPE COPPER SHIELD TAPE SHEATH FILLERS CIRCUIT IDENTIFICATION TAPE CONDUCTOR COVERING TAPE INSULATION SHIELD TAPE : Copper tape : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
101 CONDUCTOR EXTRUDED CONDUCTOR SHIELD INSULATION EXTRUDED INSULATION SHIELD SEPERATOR TAPE COPPER SHIELD TAPE SHEATH : Copper tape : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
102 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION SEPERATOR TAPE COPPER SHIELD TAPE FILLERS CIRCUIT IDENTIFICATION TAPE : Copper tape : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
103 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION SEPERATOR TAPE COPPER SHIELD TAPE : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
104 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION SEPERATOR TAPE COPPER SHIELD TAPE FILLERS CIRCUIT IDENTIFICATION TAPE : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
105 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION SEPERATOR TAPE COPPER SHIELD TAPE : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
106 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION SEPERATOR TAPE COPPER SHIELD TAPE FILLERS CIRCUIT IDENTIFICATION TAPE : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
107 CONDUCTOR INSULATION EXTRUDED CONDUCTOR SHIELD COPPER SHIELD TAPE OUTER SHEATH SEPERATOR TAPE EXTRUDED INSULATION SHIELD : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
108 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION COPPER SHIELD TAPE CIRCUIT IDENTIFICATION TAPE SEPERATOR TAPE FILLERS : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
109 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD TAPE SHEATH CONDUCTOR INSULATION COPPER WIRE AND COPPER TAPE SHIELD SEPERATOR TAPE : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
110 EXTRUDED CONDUCTOR SHIELD EXTRUDED INSULATION SHIELD SHEATH CONDUCTOR INSULATION CIRCUIT IDENTIFICATION TAPE SEPERATOR TAPE COPPER SHIELD TAPE FILLERS : Copper Tape or Copper Wire : Black polyvinyl chloride (PVC/ST2) or Black polyethylene (PE)
111 Number of core CrossSectional Area (mm²) No of wires (Min.) Conductor Diameter (mm) (Approx.) Thickness of condustor shield (mm) (Nominal) Thickness of insulation (mm) (Nominal) Thickness of insulation shield (mm) (Nominal) Area of metallic screen (mm²) Thickness of outer sheath (mm) (Nominal) Overall diameter (mm) (Approx.) DC Conductor resistance DW& ȍNP (Max.) Capacitance )NP (Nominal) Currentrating direct burial in ground DW& (A) Cable weight NJNP (Approx.) Standard Cable length PGUXP 400 500 630 800 1200 53 53 53 53 - 23.5 26.7 30.3 34.1 43 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 11.0 11.0 11.0 11.0 11.0 95 95 120 120 120 3.2 3.2 3.5 3.5 3.5 68 70 75 79 90 0.047 0.0366 0.0283 0.0221 0.0151 0.222 0.246 0.269 0.292 0.351 690 790 900 1010 1300 7,000 8,000 10,000 11,500 18,500 ' ' ' ' ' Classification Maximun circuit voltage Testing voltage Reference standard ffl0D[LPXPFRQGXFWRUWHPSHUDWXUHffi& : 72.5 kV : 90,000 Volts : TIS 2202 -2547, IEC 60840 APPLICATION Preferably laid in substations, factories and urban area . The cable shall be suitable for use in ducts, trays and direct burial in ground , subjected to immerse in water all time CABLE STRUCTURE TECHNICAL DATA : Compacted round stranded annealed copper, : Semi-Conductive cross-linked polyethylene compound : Cross-linked Polyethylene (XLPE) : Semi-Conductive cross-linked polyethylene compound : Semi-Conductive water blocking tape : Copper wire screen with copper contact tape : Copper Tape or Copper Wire : Aluminium laminate tape ffl%ODFNSRO\YLQ\OFKORULGH39&67 or Black polyethylene (PE) Conductor Conductor shield Insulation Insulation shield Water blocking tape Metallic screen Synthetic water blocking and cushioning tape Radial water barrier Sheath 69 kV - CE TIS 2202-2547, IEC 60840 69 kV 90°C CROSS LINKED POLYETHYLENE INSULATED WITH COPPER WIRE SCREEN AND POLYETHYLENE SHEATH POWER CABLE CONDUCTOR INSULATION SHEATH COPPER WIRE SCREEN NON CONDUCTIVE WATER BLOCKING TAPE ALUMINUM LAMINATE INSULATION SHIELD CONDUCTOR SHIELD COPPERCONTACT TAPE SEMI CONDUCTIVE WATER BLOCKING TAPE 1 D: Packing in drum
112 Number of core CrossSectional Area (mm²) No of wires (Min.) Conductor Diameter (mm) (Approx.) Thickness of condustor shield (mm) (Nominal) Thickness of insulation (mm) (Nominal) Thickness of insulation shield (mm) (Nominal) Area of metallic screen (mm²) Thickness of outer sheath (mm) (Nominal) Overall diameter (mm) (Approx.) DC Conductor resistance DW& ȍNP (Max.) Capacitance )NP (Nominal) Currentrating direct burial in ground DW& (A) Cable weight NJNP (Approx.) Standard Cable length PGUXP 400 500 630 800 53 53 53 53 23.5 26.7 30.3 34.1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 16.0 16.0 16.0 16.0 95 95 120 120 3.2 3.2 3.5 3.5 76 37 84 89 0.047 0.0366 0.0283 0.0221 0.170 0.187 0.203 0.219 180 785 890 1010 8,000 9,000 11,000 12,950 ' ' ' ' Classification Maximun circuit voltage Testing voltage Reference standard ffl0D[LPXPFRQGXFWRUWHPSHUDWXUHffi& : 123 kV : 160,000 Volts : TIS 2202 -2547, IEC 60840 APPLICATION Preferably laid in substations, factories and urban area . The cable shall be suitable for use in ducts, trays and direct burial in ground , subjected to immerse in water all time CABLE STRUCTURE TECHNICAL DATA : Compacted round stranded annealed copper, : Semi-Conductive cross-linked polyethylene compound : Cross-linked Polyethylene (XLPE) : Semi-Conductive cross-linked polyethylene compound : Semi-Conductive water blocking tape : Copper wire screen with copper contact tape : Copper Tape or Copper Wire : Aluminium laminate tape ffl%ODFNSRO\YLQ\OFKORULGH39&67 or Black polyethylene (PE) Conductor Conductor shield Insulation Insulation shield Water blocking tape Metallic screen Synthetic water blocking and cushioning tape Radial water barrier Sheath 115 kV - CE TIS 2202-2547, IEC 60840 115kV 90°C CROSS LINKED POLYETHYLENE INSULATED WITH COPPER WIRE SCREEN AND POLYETHYLENE SHEATH POWER CABLE 1 D: Packing in drum CONDUCTOR INSULATION SHEATH COPPER WIRESCREEN NON CONDUCTIVE WATER BLOCKING TAPE ALUMINUM LAMINATE INSULATION SHIELD CONDUCTOR SHIELD COPPERCONTACT TAPE SEMI CONDUCTIVE WATER BLOCKING TAPE
113 COPPER CONDUCTOR CABLES ²BARE CONDUCTOR² CONTENTS PAGE FHC HARD DRAWN COPPER STRANDED CONDUCTOR 115 (TIS 64-2517) 113
114
115 111 FHC HARD DRAWN COPPER STRANDED CONDUCTOR CABLE STRUCTURE CONDUCTOR ffi *CTFFTCYPEQRRGTYKTGUEQPEGPVTKEUVTCPFGFEQPFWEVQT UK\GUOO WRVQOO &KTGEVKQPQHQWVGTOQUVNC[GT< REFERENCE ffi 6+5 6+5 %10&7%614
116 112 (*% 6+5 Nominal cross sectional area (mm2 ) Breaking strength (Kgf) Maximum conductor resistance at 20C (Ω/Km) Maximum continuous current rating in free air (Ampere) Standard length (m) Cable weight (approx.) (Kg/Km) fl fl fl fl Number and diameter of wire (No/mm) fl fl fl & & & & & & & & & & & & & & & Overall conductor diameter (mm) &ffi2CEMKPIKPFTWO fl fl fl fl fl fl fl fl fl fl fl fl fl fl fl fl
ALUMINIUM CONDUCTOR CABLES BUILDING WIRES AND CABLES ALUMINIUM CONDUCTOR CABLES BUILDING WIRES AND CABLES CONTENTS PAGE 117 THWA 750 V 70 o C ALUMINIUM CONDUCTOR PVC INSULATED, 119 SINGLE CORE (TIS 293-2541) THWA-C 750 V 70o C COMPACTED ALUMINIUM CONDUCTOR PVC INSULATED, 120 SINGLE CORE (TIS 293-2541)
118
94 119 CONDUCTOR INSULATION
120 95 CONDUCTOR INSULATION
HIGH VOLTAGE POWER CABLES ALUMINIUM CONDUCTOR CABLES ALUMINIUM CONDUCTOR CABLES HIGH VOLTAGE POWER CABLES CONTENTS PAGE 121 24KV-OC 24kV CROSS-LINKED POLYETHYLENE PARTIAL INSULATED 123 ALL ALUMINIUM CABLE (ICEA S-66-524, ICEA S-93-639) 33KV-OC 33kV CROSS-LINKED POLYETHYLENE PARTIAL INSULATED 124 ALL ALUMINIUM CABLE (ICEA S-66-524, ICEA S-93-639) 15KV-CC 15kV ALL ALUMINIUM CONDUCTOR SPACED AERIAL CABLE 125 (ICEA S-66-524, ICEA S-93-639) SAC 25KV-CC 25kV ALL ALUMINIUM CONDUCTOR SPACED AERIAL CABLE 126 (TIS 2341-2564) (ICEA S-66-524, ICEA S-93-639) SAC 35KV-CC 35kV ALL ALUMINIUM CONDUCTOR SPACED AERIAL CABLE 128 (TIS 2341-2564) (ICEA S-66-524, ICEA S-93-639)
122
12397 ALUMINIUM CONDUCTOR EXTRUDED CONDUCTOR SHIELD INSULATION
124 98 ALUMINIUM CONDUCTOR EXTRUDED CONDUCTOR SHIELD INSULATION
125 ALUMINIUM CONDUCTOR EXTRUDED CONDUCTOR SHIELD INSULATION SHEATH
126 (Mё-km)
127 (Mё-km)
128
129
130
131 ALUMINIUM CONDUCTOR CABLES ²BARE CONDUCTOR² CONTENTS PAGE 131 AAC ALL ALUMINIUM STRANDED CONDUCTOR 133 (TIS 85-2548) ACSR ALUMINIUM CONDUCTOR STEEL REINFORCED 134 (TIS 85-2548)
132
103 133 HARD DRAWN ALUMINIUM WIRE
134 104 GALVANIZED STEEL WIRE HARD DRAWN ALUMINIUM WIRE
135 105 GALVANIZED STEEL WIRE HARD DRAWN ALUMINIUM WIRE
136
137 COPPER CONDUCTOR CABLES ²AUTOMOBILE WIRES AND CABLES² CONTENTS PAGE 137 AV 60o C LOW VOLTAGE FLEXIBLE CONDUCTOR FOR 139 AUTOMOBILE (TIS 118-2522 AND JIS C - 3406)
138
107 139 AV 60°C LOW VOLTAGE FLEXIBLE CONDUCTOR FOR AUTOMOBILE CABLE STRUCTURE CONDUCTOR : Flexible annealed copper wires. sizes 0.5 mm2 up to 95mm2 INSULATION : PVC-Any Colour CLASSIFICATION : Maximum conductor temperature 60°C Low voltage circuit TESTING VOLTAGE : 5,000 volts REFERENCE : TIS 118-2522 and JIS C 3406 REMARK : Nowadays the wires are produced according to two kinds of standard. But, such the Ministerial Regulations shall come into force upon their publication in Government Gazatte, the production must be in the way of THAI INDUSTRIAL STANDARD. TIS 118-2522 JIS C - 3406 CONDUCTOR INSULATION
140 108 AV TIS 118 - 2522 1 16/0.20 7/0.30 24/0.20 12/0.30 32/0.20 40/0.20 18/0.30 30/0.25 28/0.30 50/0.25 44/0.30 56/0.30 70/0.30 84/0.30 63/0.40 80/0.40 126/0.40 84/0.60 98/0.67 144/0.67 192/0.67 266/0.67 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.9 0.9 1.1 1.1 1.4 1.4 1.6 2.0 2.0 1.0 1.0 1.20 1.20 1.40 1.50 1.50 1.60 1.90 2.10 2.30 2.60 3.0 3.20 3.7 4.2 5.8 7.0 8.5 10.9 12.60 14.1 0.5 0.5 0.75 0.85 1.0 1.25 1.25 1.5 2 2.5 3 4 5 6 8 10 16 25 35 50 70 95 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 500/D 500/D 500/D 500/D 500/D 2.2 2.2 2.4 2.4 2.6 2.7 2.7 2.8 3.1 3.5 3.7 4.2 4.6 5.0 5.5 6.4 8.0 9.8 11.3 14.1 16.6 18.1 9 9 11 12 14 17 17 19 24 30 37 47 57 69 88 114 173 261 366 537 727 971 8 8 11 11 13 15 15 16 20 23 26 31 36 40 48 58 75 98 124 163 200 248 37.1 37.1 24.7 22.0 18.5 14.8 14.7 12.7 9.42 7.60 6.00 4.71 3.77 3.14 2.31 1.82 1.16 0.770 0.524 0.357 0.268 0.193 Number of core Nominal cross sectional area (mm2 ) Approx overall diameter (mm) Maximum conductor resistance at 20C (Ω/Km) Maximum continuous current rating in free air (Ampere) Standard length (m) Cable weight (approx.) (Kg/Km) Number and diameter of wire (No/mm) Approx. conductor diameter (mm) Mean value of insulation thickness (mm) (THAI INDUSTRIAL STANDARD)
141 109 AV JIS C 3406 (JAPANESE INDUSTRIAL STANDARD) 1 20/0.18 7/0.32 30/0.18 11/0.32 50/0.18 16/0.32 26/0.32 41/0.32 65/0.32 50/0.45 84/0.45 41/0.80 70/0.80 85/0.80 108/0.80 127/0.80 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.8 0.9 1.1 1.1 1.4 1.4 1.6 1.6 0.95 1.00 1.15 1.25 1.50 1.50 1.90 2.40 3.00 3.70 5.10 6.10 8.00 8.80 10.00 10.60 0.5 f 0.5 0.75 f 0.85 1.25 f 1.25 2 3 5 8 15 20 30 40 50 60 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 500/D 500/D 500/D 500/D 2.1 2.1 2.3 2.4 2.7 2.7 3.1 3.8 4.5 5.4 7.2 8.2 10.5 11.5 13.0 13.5 8.5 9 12 13 17 17 26 40 60 90 160 220 380 450 570 670 8 9 11 12 15 15 20 27 37 48 67 88 122 139 177 199 36.7 32.7 24.4 20.8 14.7 14.3 8.81 5.59 3.52 2.32 1.38 0.887 0.520 0.428 0.337 0.287 f : More flexible. c : Packing in coil. Number of core Nominal cross sectional area (mm2 ) Approx overall diameter (mm) Maximum conductor resistance at 20C (Ω/Km) Maximum continuous current rating in free air (Ampere) Standard length (m) Cable weight (approx.) (Kg/Km) Number and diameter of wire (No/mm) Average Stranded of conductor diameter (mm) Mean value of insulation thickness (mm)