PRODUCT PORTFOLIO
Medical Gas Terminal Units / Outlets
Infections, such as MRSA and C. difficile, are caused by microbes that thrive on objects we
touch every day. Antimicrobial Copper kills the microbes that cause those infections.
Three main characteristics make Antimicrobial Copper the most effective touch surface
material:
Continuously kills microbes
• Efficacy as an antimicrobial is scientifically proven to be far more effective than silver-
containing coatings
• Proven to continuously kill the microbes that cause infections
• The only solid metal touch surface approved by the US Environmental Protection
Agency (EPA).
G. Samaras SA uses antimicrobial copper for the Never wears out
caps of the gas outlets. This kind of cap is suit- • Continuous and ongoing antimicrobial action
able for the prevention and/or elimination of • Remains effective even after repeated wet and dry abrasion and re-contamination
various microbes, bacterias, fungi and viruses, • Natural oxidation does not impair efficacy.
ensuring maximum purity in supplying medical
gases to the patient. Safe to use
• Not harmful to people or the environment
• Inherently antimicrobial, no chemicals added
• Completely recyclable.
3.3.2 Quick action fittings/probes/adapters
G.SAMARAS S.A. manufactures high quality quick action fittings/adapters/probes ensuring great durability. They are being produced
from brass (agss from aluminum) while they bear sticker or engrave of the gas. They meet the following international standards:
NORM TYPE OF GAS
1. ENV 737-6 (European Standard) O2 N2O AIR/MA4 Vac Air800/SA7 AGSS Special
•••••
2. AFNOR NF S 90-116 (French Standard) ••••
3. DIN 13260-2 (German Standard) •••• N2/CO2
4. BS 5682 (British Standard) •••••
5. SS 875 24 30 (Svensk Standard) ••••
6. ISO 9170-2 (International Standard) • AirMotor
7. SANS 1409:2008 (South Africa Standard) •••••
8. NIST EN 739 (International Standard) •••••
Quick action fittings:
- direct coupling for antistatic tubes
- 90° coupling
- Y connections with gas outlets
- direct coupling to 1/8”
- direct coupling to 1/4”
G. Samaras S.A. MEDICAL GAS SYSTEMS 49
3.3.3 PG profiles
The specific aluminum profile can be considered as a substitute for a bed head unit. It is a simple and cost efficient solution and is in-
dicated in cases of minimum available space. It can be installed either wall mounted (PG-EX) or wall embedded (PG-EM) while it can
accommodate basic components of a typical bed head unit such as medical gas outlets, electrical sockets, switches, etc.
External mounted PG-EX aluminium profile in anodized color Internal mounted PG-EM aluminium profile in white (RAL 9016)
Number Recommended
of gas outlets length of profile
1 9cm
2 18cm
3 27cm
4 36cm
5 45cm
6 (with AGSS) 65cm
Examples of internal mounted PG-EM
aluminium profile with electrical
sockets, gas outlets and combination
of them in woodstyle color or stan-
dard RAL9016.
Option for one gas outlet in plastic box
66.5
Wall chase for Wall chase
electrical cables for medical gas
pipework
68 600 100 100 100 100
108 108 356 EQ cable
108 Socket cables
124
Data cables
372
PG-EX
66.5 0653
0653
0653
Oxygen A ir Vacuum Gas Pipes
(O2:10, AIR:10, Vac:12)
DIN13260-2
DIN13260-2
DIN13260-2
SECTION 800
68
124 66.5 800
PG-EM 108 108 Ox y gen V a c u um
80 124
B S 5682:1998
0653
B S 5682:1998
0 6 53
Profile “PG” for gas outlet or electrical equipment for vertical, horizontal, embented (PG-EM) or external mounted (PG-EX). Standard colors RAL9016 or anodized gray.
50 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Control and Reducer Panel
3.4 CONTROL AND REDUCER PANEL
The 2nd stage pressure regulator units are equped withline pressure regulators of 25–438m³/h
3.4.1 Low and middle pressure reducers up to 30bars
TYPE OF TYPE OF GAS INLET MIN. INLET OUTLET (m³/h) CONNECTION
REDUCER PRESSURE (P1) PRESSURE (P1) PRESSURE (P2) (inches)
LPR/GS1-L4 O2, N2O, Air, CO2, N2 25 (4bar)
LPR/GS2-L8 Air800 8bar 6bar 4/5bar 28 (8bar) 3/8”
LPR/GS2D-L4 S/L 10bar 9bar 7/8bar 50 (4bar) 3/8”
LPR/GS2D-L8 S/L O2, N2O, Air, CO2, N2 8bar 6bar 4/5bar 56 (8bar) 3/8”
LPR/GS3D-L4/8A S/L Air800 10bar 9bar 7/8bar 56 (8bar) 3/8”
LPR/GS3-DL 10bar 9bar 4/5 & 7/8bar 144 (8bar) 3/8”
LPR/GS4-DV Air / Air800 8/10bar 6/9bar 4/5 & 7/8bar 438 (8bar) 1/2”
O2, N2O, Air, CO2, N2 / Air800 8/10bar 6/9bar 4/5 & 7/8bar 3/4”
O2, N2O, Air, CO2, N2 / Air800
140 140
1 5 26.5
2
10EN 837-1 4 6EN 837-1
5
28
15
65 68.5 0 6 6 0 10 9
40
3 11 4
12
0653 G.S.
O2, N2O, Air, CO2
LPR GS LOT 0513
P1=8bar P2=4,5bar
G3/8" connection 7 11
12.5 10
OFF P1=8bar - P2=4.5bar
ON ON OFF
Oxygen-O2
89 8
108 13
49.5 35
LPR GS1-L4, LPR GS2-L8
200 260
170 230
100 5 130 5
3 +- 3 + -
6 6
0653 G.S. 4 1 4
7 O2, N2O, Air, CO2 6 7
7 LPR GS LOT 4414 7 0653 G.S. 6
6 P1=8bar P2=4,5bar O2, N2O, Air, CO2 10
30 45 6
30 75 LPR GS LOT 4414 5
6
P1=8bar P2=4,5bar
8
G.SAMARAS S.A. 10 4 EoNxS8yg37e-n1 6 2 G.SAMARAS S.A. 4S6 2
28 EoNx8yg37e-n1
medical gas systems medical gas systems
0 bar 10 28
219 OFF P1=8bar - P2=4.5bar CL.2,5 OFF P1=8bar - P2=4.5bar
115 0 bar 10
ON ON G.Samaras S.A. ON ON CL.2,5
MEDICAL GAS SYSTEMS
AIR OFF OXYGEN OFF G.Samaras S.A.
MEDICAL GAS SYSTEMS
69 9
12 12
+ 1+
5
5 --
13
LPR GS1D-L4S, LPR GS2D-L8S LPR GS1D-L4L, LPR GS2D-L8L
G. Samaras S.A. MEDICAL GAS SYSTEMS 51
170 370 170
5 170
100
-+ 5 ⌀67 5
+- 1/2" 1/2" 0
4 3 0653 G.S. 4
Air800 6
6 0653 G.S. 6 6 72 7
O2, N2O, Air, CO2 LPR GS2 LOT 4414
P1=10bar P2=8bar
LPR GS LOT 4414
P1=8bar P2=4,5bar
4S6 7 G.SAMARAS S.A. 10 5 S 10 7 G.SAMARAS S.A. 10 5 S 10 3 4
EoNx8yg37e-n1 7 EoNx8yg37e-n1 7 EoNx8yg37e-n1 30 2
2 medical gas systems medical gas systems 1 145
28
OFF P1=8bar - P2=4.5bar bar 15 OFF P1=10ar - P2=8bar bar 15
0 bar 10 16 16
CL.2,5 0 0
G.Samaras S.A. ON ON CL.2,5 ON ON CL.2,5
MEDICAL GAS SYSTEMS G.Samaras S.A. G.Samaras S.A.
AIR OFF AIR800 OFF
MEDICAL GAS SYSTEMS MEDICAL GAS SYSTEMS
96 66 69 5
12
12
- -+ + 5
-+
5 5
LPR/GS3D-L4/8S Line pressure reducer
144m3/h LPR GS3-DL
130 230 490 230 ⌀114
230
5 5 G1/2"RH
1/2" G3/4"RH
-+ +-
3/4" G1"RH
1"
83 7
4 3 4 4
2
6 0653 G.S. 6 6 0653 G.S. 6 41 3
O2, N2O, Air, CO2 10 7 Air800 10 213 5
LPR GS LOT 4414 6 7 LPR GS2 LOT 4414 6
6 P1=10bar P2=8bar
P1=8bar P2=4,5bar
4S6 7 G.SAMARAS S.A. 5 S 10 G.SAMARAS S.A. 5 S 10
EoNx8yg37e-n1 7 EoNx8yg37e-n1 EoNx8yg37e-n1
2 medical gas systems medical gas systems 1
28
OFF P1=8bar - P2=4.5bar bar 15 OFF P1=10ar - P2=8bar bar 15
0 bar 10 16 16
CL.2,5 0 0
G.Samaras S.A. ON ON CL.2,5 ON ON CL.2,5
MEDICAL GAS SYSTEMS G.Samaras S.A. G.Samaras S.A.
AIR OFF AIR800 OFF
MEDICAL GAS SYSTEMS MEDICAL GAS SYSTEMS
96 9
12
12
- +
5 5
LPR/GS3D-L4/8L Line pressure reducer
438m3/h LPR GS4-DV
INDEX 8 G1/8’’ female corner connection (set with 11)
1 Manometer Ø40 0÷16bar 9 NIST emergency outlet
2 Manometer Ø40 0÷10bar
3 Inlet connection (high pressure) Optional O2/Air/N2O outlet/NIST
4 Outlet connection (low pressure) 10 Support bracket
5 Adjustment screw 11 Fitting with Ø0,4 mm hole
6 On/off plastic ball valve 12 Digital pressure switch (ON/OFF)
7 Access plug to the filter and the pressure 13 Analogue transducer (4÷20mA, 16bar)
regulators valve
52 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Control and Reducer Panel
3.4.2 Second Stage Pressure Regulator Unit (Y/S GS N S/D) 93/42 MED
The 2nd stage pressure regulator unit con- GASES
trols and isolates the medical gases (O2,
N2O, Air, CO2) that feed the gas outlets. Second reducer panels O2 N2O AIR/MA4 Vac Air800SA7 Special gas
The 2nd stage panel is suitable for flash or 1. One gas single
chased distribution networks, contains re- 2. One gas double •
ducers, shut-off valves (upstream and down- 3. Two gas single
stream of reducers), pressure gauges, 4. Two gas double •
gas-specific connectors and low-high pres- 5. Three gas single
sure switches, according to EN ISO 7396-1, 6. Three gas double ••
HTM 02-01 standards. 7. Four gas single
8. Four gas double ••
Output @ 4bar 9. Five gas single
10. Five gas double • ••
26m³/h 11. Six gas single
144 m3/h 12. Six gas double • ••
180 m3/h
438 m3/h ••• •
2 x 26m³/h
2 x 144 m3/h ••• •
2 x 180 m3/h
2 x 438 m3/h ••• ••
Y/S GS N S/D ••• ••
N: Number of gases ••• •••
S: Single
D: Double ••• •••
• Sensors: can be analog 4-20mA or digital On/Off
• Alarm panels: can be set or separate
• Emergency inlet point: can be NIST type-N or gas specific type-S (according to table 3.3)
• The 2nd Reducer Panels can be either type-E with external manometers - emergency inlet point (for easy ac-
cess) or Type-S with internal placement of manometers - Emergency Inlet Point visable through plexiglass cover.
Flow rate with nitrogen refers to normal pressure and temperature conditions.
For the other gases multiply the values for nitrogen by the following coefficients:
AIR = 0.98
OXYGEN = 0.93
NITROUS OXIDE = 0.79
CARBON DIOXIDE = 0.79
2nd stage Reducer Panel of 3 gases O2, Air, Vac (double reducers)
2×25m³/h, Type-E
G. Samaras S.A. MEDICAL GAS SYSTEMS 53
Second stage pressure regulator units with alarm panel
EARTH 3x2,50mm EARTH 3x2,50mm EARTH 3 3x2,50mm
1x 4mm 230V, 50/60Hz 1x 4mm 230V, 50/60Hz 1x 4mm 230V, 50/60Hz
0653 G.S . 0 G.S . 0 G.S . 0 G.S . 0653 G.S . 0 G.S . 0 G.S . 0 G.S . 0 G.S . 0653 G.S . 0 G.S . 0653 G.S . 0 G.S . 0 G.S . 0 G.S . 0 G.S .
O2, N2O, Air, C O2 O O O O2, N2O, Air, C O2 O O O O O2, N2O, Air, C O2 O O2, N2O, Air, C O2 O O O O
L OT 3511 L OT 3511 L OT 3511 L OT 3511 L OT 3511 L OT 3511 L OT 3511 L OT 3511 L OT 3511 L OT 3511
L PR G S L OT 3511 P P 2=4,5bar P P 2=4,5bar P P 2=4,5bar L PR G S L OT 3511 P P 2=4,5bar P P 2=4,5bar P P 2=4,5bar P L OT 3511L P R G S L OT 3511 P P 2=4,5bar L PR G S L OT 3511 P P 2=4,5bar P P 2=4,5bar P L OT 3511 P 2=4,5bar
P 2=4,5barP
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 2=4,5barP 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
4 6 4 6 400 300 4 6 4 6
2 8 2 8 500 200 2 8 2 8
0 10 0 10 600 0 10 0 10
100
700
760 mmHg
OFF P 1=8 bar - P 2=4.5bar OFF P 1=8 bar - P 2=4.5bar OFF P 1=8 bar - P 2=4.5bar OFF P 1=8 bar - P 2=4.5bar
A IR
ON ON ON ON VAC ON ON ON ON
OXY GE N OXY GE N OXY GE N
OFF OFF OFF OFF
650 450
450SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal ACT Normal ACT Normal
700LINK LINK LINK
450SILENCEMENUTEST SILENCE MENU TEST SILENCE MENU TEST
HP HP HP
LP LP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
450 450 550
Y/S GS 1D/L6 Y/S GS 2D/L6 Y/S GS 2D/L6 Y
EARTH 3x2,50mm
1x 4mm 230V, 50/60Hz
EARTH 3x2,50mm
1x 4mm 230V, 50/60Hz
0653 G.S . 0 G.S . 0 G.S .
O2, N2O, Air, C O2 O O
L OT 3511 L OT 3511
L PR G S L OT 3511 P P 2=4,5bar P P 2=4,5bar
P 1=8bar P 2=4,5bar
OFF P 1=8 bar - P 2=4.5bar 4 6
2 8
0 10
ON ON OFF
NIT R O US O XIDE
400 300 400 300
500 200 500 200
600 600
100 100
700 700
760 mmHg 760 mmHg
VAC VAC
0 G.S . 0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S . 0 G.S . 0 G.S .
O O2, N2O, Air, C O2 O2, N2O, Air, C O2 O2, N2O, Air, C O2 O2, N2O, Air, C O2 O A
L OT 3511 L OT 3511 LOT 3511
P P 2=4,5bar L PR G S L OT 3511 L PR G S L OT 3511 L PR G S L OT 3511 L PR G S L OT 3511 P P 2=4,5bar
P P 2=8bar
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
OFF P 1=8 bar - P 2=4.5bar 4 6 OFF P 1=8 bar - P 2=4.5bar 4 6 P 1=8 bar - P 2=4.5bar 4 6 P 1=8 bar - P 2=4.5bar 4 6
2 8 2 8 2 8 2 8
0 10 0 10 0 10 0 10
OFF OFF
A IR
ON ON ON ON ON ON ON ON
OXY GE N OXY GE N OXY GE N
OFF OFF OFF OFF
SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal ACT Normal
LINK LINK
SILENCE MENU TEST SILENCE MENU TEST
HP HP
LP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
580 600
Y/S GS 3D/L6 Y/S GS 4D/L6
EARTH 3x2,50mm EARTH 3x2,50mm
1x 4mm 230V, 50/60Hz 1x 4mm 230V, 50/60Hz
400 300 400 300
500 200 500 200
600 600
100 100
700 700
760 mmHg 760 mmHg
VAC VAC
0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S .
O2, N2O, Air, C O2 O2, N2O, Air, C O2 O2, N2O, Air, C O2 A ir800
L PR G S L OT 3511 L PR G S L OT 3511 L PR G S L OT 3511 L PR G S 2 LOT 3511
P 1=10ba r P 2=8bar
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
OFF P 1=8 bar - P 2=4.5bar 4 6 OFF P 1=8 bar - P 2=4.5bar 4 6 OFF P 1=8 bar - P 2=4.5bar 4 6 OFF P 1=10 ar - P 2=8bar 10
2 8 2 8 2 8 5
0 10 0 10 0 10 15
0 16
ON ON OFF ON ON OFF ON ON OFF ON ON OFF
OXY GE N NIT R O US O XIDE NIT R O US O XIDE A IR 800
950
950
0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S .
O2, N2O, Air, C O2 A ir800 O2, N2O, Air, C O2 O2, N2O, Air, C O2
L PR G S L OT 3511 L PR G S 2 LOT 3511 L PR G S L OT 3511 L PR G S L OT 3511
P 1=10ba r P 2=8bar
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
4 6 OFF P 1=8 bar - P 2=4.5bar OFF P 1=10 ar - P 2=8bar 10 OFF P 1=8 bar - P 2=4.5bar 4 6 OFF P 1=8 bar - P 2=4.5bar 4 6
2 8 A IR 5 2 8 A IR 2 8
0 10 15 0 10 0 10
0 16
ON ON ON ON ON ON ON ON
A IR 800 OXY GE N
OFF OFF OFF OFF
SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal ACT Normal
LINK LINK
SILENCE MENU TEST SILENCE MENU TEST
HP HP
LP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
650 650
Y/S GS 5D/L6 Y/S GS 5D/L6
54 visit us on www.gsamaras.gr
Second stage pressure regulator units without alarm panel PRODUCT PORTFOLIO
Control and Reducer Panel
1ExAR4TmHm² LiYCY 6x 0,75mm²
600 VAC
· GND VAC
· O2 H.P. DH1
1ExAR4TmHm²LiYCY 3x 0,75mm² 1ExAR4TmHm²LiYCY 4x 0,75mm² · O2 L.P. DL1
O2 O2 · Air H.P. DH2
· Air L.P. DL2 400 300
· Vac L.P. DL3 500 200
· EARTH
600
VAC 100
700
760 mmHg
O2 O2 VAC ·
·
DH1 ·
DL1 ·
·
· GND O2 O2 AIR AIR ·
· O2 H.P. ·
· O2 L.P.
· EARTH
0653 G.S . 0653 G.S .
O2, N2O, Air, C O2 O2, N2O, Air, C O2
L PR G S L OT 3511
L PR G S L OT 3511 P 1=8bar P 2=4,5bar
P 1=8bar P 2=4,5bar
400
4 6 400 300 0653 G.S . 0653 G.S .
2 8 500 200 O2, N2O, Air, C O2 O2, N2O, Air, C O2
0 10 600 L PR G S L OT 3511 L PR G S L OT 3511
4 6 100 P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
2 8
OFF P 1=8 bar - P 2=4.5bar 700
0 10 760 mmHg
350
OFF P 1=8 bar - P 2=4.5bar ON ON OFF VAC
OXYGEN
ON ON OFF 4 6 4 6
OXYGEN 2 8 2 8
OFF P 1=8 bar - P 2=4.5bar 0 10 OFF P 1=8 bar - P 2=4.5bar 0 10
A IR
ON ON ON ON
OXYGEN
OFF OFF
· GND DH1
· O2 H.P. DL1
· O2 L.P. DL3
· Vac L.P.
· EARTH
350 450 550
Y/S GS 1D Y/S GS 2D Y/S GS 2D
LiYCY 10x 0,50mm² 1ExAR4TmHm² LiYCY 10x 0,50mm² 1ExAR4TmHm²
· DL1 O2 AIR · DL3 VAC N2O AIR800 VAC · DL1 O2 AIR · DL3 VAC N2O AIR800 VAC
VAC VAC
· EARTH · EARTH
· GND· DH1 · DH2 · DH4 · DH5 · GND· DH1 · DH2 · DH4 · DH5
· DL2 · DL4 · DL5 · DL2 · DL4 · DL5
400 300 400 300
500 200 500 200
1ExAR4TmHm² LiYCY 8x 0,75mm² 600 600
100 100
700 700
760 mmHg 760 mmHg
VAC VAC
N2O N2O VAC O2 O2 N2O N2O N2O N2O AIR 8 AIR 8
0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S .
O2, N2O, Air, C O2 O2, N2O, Air, C O2 O2, N2O, Air, C O2 A ir800
L PR G S L OT 3511 L PR G S L OT 3511 L PR G S L OT 3511
L P R G S 2 L OT 3511
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
P 1=10bar P 2=8bar
0653 G.S .
O2, N2O, Air, C O2 900 4 6 4 6 900 4 6
L PR G S L OT 3511 2 8 2 8 2 8
P 1=8bar P 2=4,5bar
0 10 0 10 0 10
OFF P 1=8 bar - P 2=4.5bar OFF P 1=8 bar - P 2=4.5bar OFF P 1=8 bar - P 2=4.5bar OFF P 1=10 ar - P 2=8bar 10
5
4 6 ON ON ON ON ON ON ON ON
2 8 OXYGEN NIT R OUS OXIDE NIT R OUS OXIDE A IR 800 15
0 16
0 10
OFF OFF OFF OFF
OFF P 1=8 bar - P 2=4.5bar
ON ON OFF
NIT R OUS OXIDE
400 300
500 200
600
100
700
760 mmHg
600 O2 · GND O2 AIR AIR A IR C .AIR AIR 800 O2 O2 AIR AIR
· O2 H.P. DH1
· O2 L.P. DL1
· Air H.P. DH2
· Air L.P. DL2
· Vac L.P. DL3
· N2O H.P. DH4
· N2O L.P. DL4
· EARTH
0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S . 0653 G.S .
O2, N2O, Air, C O2 O2, N2O, Air, C O2 O2, N2O, Air, C O2 A ir800 O2, N2O, Air, C O2 O2, N2O, Air, C O2
L PR G S L OT 3511 L PR G S L OT 3511
L PR G S L OT 3511 L P R G S 2 LOT 3511 L PR G S L OT 3511 L PR G S L OT 3511
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=10bar P 2=8bar
P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar P 1=8bar P 2=4,5bar
4 6 4 6 4 6 OFF P 1=8 bar - P 2=4.5bar 10 OFF P 1=10 ar - P 2=8bar 10 OFF P 1=8 bar - P 2=4.5bar 4 6 OFF P 1=8 bar - P 2=4.5bar 4 6
2 8 2 8 2 8 A IR 5 5 2 8 A IR 2 8
0 10 0 10 0 10 15 15 0 10 0 10
0 0
ON ON ON ON ON ON ON ON
16 A IR 800 16 OXYGEN
OFF P 1=8 bar - P 2=4.5bar OFF P 1=8 bar - P 2=4.5bar
A IR
OFF OFF OFF OFF
ON ON ON ON
OXYGEN
OFF OFF
550 580 650
Y/S GS 4D Y/S GS 5D Y/S GS 5D
G. Samaras S.A. MEDICAL GAS SYSTEMS 55
NET B' STAGE 10EN 837-1 10EN 837-1 Air A ir - 8 0 0
PRESSURE AIR 5 5
NET B' STAGE 10EN 837-1 10EN 837-1
PRESSURE AIR800 15 15 5 5
0 0
15 15
Air A ir - 8 0 0 0 0
OFF ON
· + Vs OFF ON
· - IN OFF ON
· + Vs
· - IN
· EARTH
OFF ONNET B' STAGE
OFF ONPRESSURE AIR
OFF ON NET B' STAGE
PRESSURE AIR800
550
· + Vs 500
· - IN
· + Vs
· - IN
· EARTH
OFF ON OFF ON
OFF ON OFF ON
OFF ON OFF ON
10EN 837-1 10EN 837-1
5 5
15 15
0 0
450 400
2nd stage Reducer Panel of 1 gas Air (double reducers) 2x438m³/h @4bar & 1x438m³/h @ 8bar
2nd stage Reducer Panel 2x144m³/h@4bar + 1x144m³/h@8bar for air
10EN 837-1 NET A' STAGE 10EN 837-1
5 PRESSURE O2 5
NET B' STAGE
15 PRESSURE O2 15
0 0
NET A' STAGE OFF ON · + Vs OFF ON OFF ON
PRESSURE O2 OFF ON · - IN
NET B' STAGE · + Vs
PRESSURE O2 · - IN
· EARTH
· + Vs
· - IN
· + Vs
· - IN
· EARTH
550 500
OFF ON OFF ON OFF ON
OFF ON
10EN 837-1
10EN 837-1 5
5
15
15 0
0
400
400
2nd stage Reducer Panel 2x144m³/h @8bar or @4bar
2nd stage Reducer Panel of 1 gas 2x438m³/h @8bar or @4bar
LiYCY 6x 0,50mm²
EARTH
1x 4mm²
O2 Vac Air
• + Vs • + Vs • + Vs • EARTH
• - IN 1 • - IN 3 • - IN 4
400 VAC
500 EN 837-1 300 Air
200
600
100
700 mmHg
760
Air
OFF ON OFF ON
OFF ON OFF ON
2x144 m3/h10EN837-1
5
15
0
10EN 837-1
5
15
0
950
O2 O2
OFF ON OFF ON
OFF ON OFF ON
2x144 m3/h10EN837-1
5
15
0
46
EN 837-1
28
0 10
Control point of vacuum with ball valve, 500
manometer, sensor, screwed nipples,
according to HTM 02-01
2nd stage Reducer Panel of 3 gases O2, Air, Vac (double reducers) 2x144m³/h Type-S
56 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Control and Reducer Panel
3.4.3 Reducers
High pressure reducers up to 300bars (for different gases)
Type Supply Pressure Outlet Inlet-Outlet Flow Rate
Pressure Range Pressure Connection
m³/h l/min
of Reducer max. bar bar bar W21,7x1/14” 177 2950 1/2" 1/2"
HPR GS1-F 300 0 … 12 8 G½” 160 2667 3 4
HPR GS2-B 300 0 … 12 8 G½” 75 1250
HPR GS3-DL* 300 0 … 40 8 G½” 170 2830 41 202
HPR GS4-DH* 300 0 … 40 8 G½” 30 1800
HPR GS5-DL 300 0 … 40 8 G½” 50 1800
HPR GS6-DL 300 0 … 40 8
*Metal diaphragm up to 5.0 purity
∅63 4 ∅63 185 7
120 181
100 200 W 21,7x1/14" 5 OXYGEN 10
OXYGEN EN 837-1 5
EN 837-1
Line pressure regulator 170m3/h LPR GS4-DH
0 300 0 15 7
bar 315 bar 16
1/2"
1/2"
∅167 3 3/8"
4
5 ∅79
3/8"
185
5
Line pressure regulator 160m3/h HPR/GS2-B
1/2" ∅∅72
1/2"
3
7
93
HP 3 The index flow rates refer to Air. For other gases multi- 156
ply the values for Air by the following factors:
W 21,7x1/14"
FLOW RATE CORRECTION FACTOR 333 4
Line pressure regulator 180m3/h HPR/GS-F Type of Gas Factor 4
INDEX Compressed Air Air 1.00 142 7
1 Manometer Ø40 0÷16bar Oxygen 0.95
2 Manometer Ø40 0÷10bar Nitrous Oxide O2 0.80 5
3 Inlet connection (high pressure) Carbon Dioxide N2O 0.81
4 Outlet connection (low pressure) Nitrogen CO2 1.02 Line pressure regulator 75m3/h LPR GS3-DL
5 Adjustment screw Hydrogen N2 3.80
6 On/off plastic ball valve Argon H2 0.85
7 Access plug to the filter and the pressure Helium Ar 2.70
regulators valve Propane 0.80
He
C3H8
G. Samaras S.A. MEDICAL GAS SYSTEMS 57
3.4.4 Area valve service unit (KIB GS N) 93/42 MED
The AVSU are fitted to all medical gas and vacuum services in a prominent and ac-
cessible position at the entry of wards, theatres, intensive care, recovery rooms, etc.
The AVSU panel is conforming to EN ISO 7396-1, HTM 02-01 standards and contains:
- Shut-off valves (for Oxygen use)
- Pressure/Vacuum gauges
- Gas-specific connectors
- Pressure sensors (digital or transducer)
all placed inside a metal box galvanized and coated with electrostatic paint.
AVSU with alarm panel 450 450 308 450
65 278 193 65
225 230V 50/60Hz 128 65 230V 50/60Hz 78 230V 50/60Hz
3x2,50mm² 65 3x2,50mm ²
EARTH EARTH EARTH 65 3x2,50mm ²
Repeater 1x 25 Repeater 1x 4mm² 25
UTP 4mm² UTP 65Repeater 1x 4mm² 25
55 UTP
25
55 340 55 340
25 25
100 ෘ15 100
ෘ15 100
ෘ15 ෘ15
ෘ15
ෘ15
O2 O2 VAC O2 AIR VAC
Ox ygen Ox ygen 400 Ox ygen Air 400
500 EN 837-1 300 500 EN 837-1 300
10EN 837-1 0653 DIN132 60-2 10EN 837-1 0653 DIN132 60-2 10EN 837-1 DIN132 60-210EN 837-1
5 5 200 5 DIN132 60-2 5 200
600 600
15 15 15 15
0 0 100 0 0 100
700 mmHg 0653 700 mmHg
0653
760 760
SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal ACT Normal ACT Normal
LINK LINK LINK
SILENCE MENU TEST SILENCE MENU TEST SILENCE MENU TEST
HP HP HP
LP LP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
Oxygen - O 2 Oxygen - O 2 Vacuum Oxygen - O 2 Air Vacuum
Vac Vac
10EN 837-1 10EN 837-1 10EN 837-1 10EN 837-1
5 5 400 5 5 400
500 EN 837-1 300 500 EN 837-1 300
15 15 15 15
0 0 200 0 0 200
600 600
100 100
700 mmHg 700 mmHg
760 760
400
400
400
SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2 SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal ACT Normal ACT Normal
LINK LINK LINK
SILENCE MENU TEST SILENCE MENU TEST SILENCE MENU TEST
HP HP HP
LP LP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
450 450 450
KIB GS 1/L6 KIB GS 2/L6 KIB GS 3/L6
KIB GS N 575 548 700 663 825
433 65 548
N: Number of gases 423 318 433
308 203 318
OPTIONS: 193 88 203
S: Sensor (Analog 4-20mA or Digital 78 88
2/6, 4/ , 9/15 or Without sensor) EARTH 230V 50/60Hz EARTH 230V 50/60Hz EARTH 230V 50/60Hz
E: Emergency gas outlet (NIST, 3x2,50mm ²
65 65 65Repeater 1x 4mm² 65 3x2,50mm ² 65Repeater 1x 4mm ² 65 65 65 3x2,50mm² 65 65 65 65 65 65Repeater 1x 4mm²
AFNOR, DIN, SS, BS or Without) 25
A: Alarm panel (L5 , L6 or Without) UTP UTP 25 UTP
55 455 65 570 65 685
25 25
ෘ15 100 ෘ15 100 ෘ15
ෘ18 ෘ15 ෘ15
ෘ15 ෘ18 ෘ15
ෘ15 ෘ15 ෘ18
ෘ15 ෘ15
ෘ15
O2 AIR VAC N2O O2 AIR VAC N2O AIR800 O2 AIR VAC N2O AIR800 CO2
Ox ygen A ir NitrousOx ide Ox ygen A ir NitrousOx ide Ox ygen Air 400 NitrousOx ide
500 EN 837-1 300
400 400 10EN 837-1 10EN 837-1 10EN 837-1 10EN 837-1 10EN 837-1
500 EN 837-1 300 500 EN 837-1 300 5 5 200 5 5 5
600
200 200 15 15 15 15 15
600 600 0 0 100 0 0 0
700 mmHg
100 100
700 mmHg 700 mmHg 760
DIN132 60-2
760 760
DIN132 60-2
DIN132 60-2
10EN 837-1 DIN132 60-210EN 837-110EN 837-110EN 837-1 DIN132 60-210EN 837-110EN 837-1 10EN 837-1 0653
5 5 5 5 5 5 5 0653
DIN132 60-2 DIN132 60-2 0653
15 DIN132 60-2 15 15 15 DIN132 60-2 15 15 15
0 0 0 0 0 0 0
0653
0653
0653
0653
0653
0653
SYSTEM SYSTEM SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT ACT ACT Normal
LINK GAS O2 Air Vac N2O Air800 CO2 LINK GAS O2 Air Vac N2O Air800 CO2 LINK
SILENCE Normal SILENCE Normal SILENCE
MENU TEST
MENU TEST MENU TEST HP
HP HP
LP
LP LP +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
Oxygen - O2 A ir V ac uum N itr ous Ox ide Air-8 00 Ca rbon Diox ide
Vac N2O CO2
Oxygen - O 2 Air Vacuum Nitrous Oxide Oxygen - O 2 Air Vacuum Nitrous Oxide Air-800 10EN 837-1
Vac N 2O Vac N 2O 5 10EN 837-1
10EN 837-1 5
400 10EN 837-1 10EN 837-1 400 10EN 837-1 10EN 837-1 10EN 837-1 400 10EN 837-1 5 10EN 837-1 10EN 837-1 400 10EN 837-1 15
40055 500 EN 837-1 300 5 5 5 500 EN 837-1 300 5 5 5 500 EN 837-1 300 5 0 15
100 250 15 0
15 15 200 15 15 15 200 15 0 15 15 200 15
400006000 0 0 600 0 0 0 600 0
100 250
100 100 100
700 mmHg 700 mmHg 700 mmHg
760 760 760
SYSTEM SYSTEM SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT ACT ACT Normal
LINK LINK LINK
SILENCE GAS O2 Air Vac N2O Air800 CO2 SILENCE GAS O2 Air Vac N2O Air800 CO2 SILENCE MENU TEST
Normal Normal
HP
MENU TEST MENU TEST
HP HP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
LP LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
575 700 825
KIB GS 4/L6 KIB GS 5/L6 KIB GS 6/L6
58 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Control and Reducer Panel
AVSU without alarm panel
450 430 600 65
65 315 65
350 305 65 200 65
190 65 190 85 65
105 300 75 65 75 65
80 65
40 250
115 40 350 50 470
O1590 90 90 90
O18350 350 350
O15 O15O2LiYCY 3x 0,50mm²O2VACLiYCY 4x 0,50mm² O2 AIR VAC LiYCY 6x 0,50mm² O2 AIR VAC N2O LiYCY 8x 0,50mm²
O15 O15EARTH EARTH EARTH EARTH
1x 4mm² 1x 4mm² 1x 4mm² 1x 4mm²
O15
4 6 O1846400300 4 6 4 6 400 300 4 6 4 6 400 300 4 6
2 8 O1528500 200 2 8 2 8 500 200 2 8 2 8 500 200 2 8
O18
0 10 O15010600 0 10 0 10 600 0 10 0 10 600 0 10
O15
O15 100 100 100
O15 700 700 700
O15 760 mmHg 760 mmHg 760 mmHg
O18
DH1 O18 DH1 DH1 DH1 12
· DL1 O15 · DL1 · DL1 · DL1
· O15 · DL3 · DL3 · DH2 · GND
O15 · · DH4 · DL2 · O2 H.P. DH1
· DL4 · DL3 · O2 L.P. DL1
O15 · · DH4 · Air H.P. DH2
· DL4 · Air L.P. DL2
· GND DH1 · GND DH1 · GND · · Vac L.P. DL3
· O2 H.P. DL1 · O2 H.P. DL1 · O2 H.P. DH1 · N2O H.P. DH4
· O2 L.P. · O2 L.P. DL3 · O2 L.P. DL1 · N2O L.P. DL4
· EARTH · Vac L.P. · Vac L.P. DL3 · EARTH
· N2O H.P. DH4
· EARTH · N2O L.P. DL4
· EARTH
12
350 4 6 350 4 6 400 300 4 6 4 6 400 300 4 6 4 6 4 6 400 300
2 8 2 8 500 200 2 8 2 8 500 200 2 8 2 8 2 8 500 200
0 10 0 10 600 0 10 0 10 600 0 10 0 10 0 10 600
100 100 100
700 700 700
760 mmHg 760 mmHg 760 mmHg
Oxygen - O2 Oxygen - O2 V a c uum Oxygen - O2 N itr ous Ox ide V a c uum Oxygen - O2 A ir N itr ous Ox ide V a c uum
Vac N2O Vac N 2O Vac
300 350 450 600 90
KIB GS 1 K KIB GS 2 KIB GS 3 KIB GS 4
545 700 65 825
430 65 545 65
315 65 545 65
200 65 430 65
85 65 315 65
200 65
50 580 85 65
60 690
350 O2 AIR VAC N2O AIR800 LiYCY 10x 0,50mm² O2 AIR VAC N2O AIR800 CO2 LiYCY 12x 0,50mm²
90 EARTH EARTH
1x 4mm² 1x 4mm²
350
90464640030046 10
2 8 2 8 500 200 2 8 5
0 10 0 10 600 0 10 15
0 16
100 4 6 4 6 4 6 10 4 6
2 8 2 8 2 8 5 2 8
700 400 300
760 mmHg 0 10 0 10 500 200 0 10 15 0 10
0 16
600
100
700
760 mmHg
12 DH1 · GND DH1
· DL1 · O2 H.P. DH1 · DL1
· GND · DH2 · O2 L.P. DL1 · DH2
· O2 H.P. DH1 · DL2 · Air H.P. DH2 · DL2
· O2 L.P. DL1 · DL3 · Air L.P. DL2 · DL3
· Air H.P. DH2 · DH4 · Vac L.P. DL3 · DH4
· Air L.P. DL2 · DL4 · N2O H.P. DH4 · DL4
· Vac L.P. DL3 · DH5 · N2O L.P. DL4 · DH5
· N2O H.P. DH4 · DL5 · Air8 H.P. DH5 · DL5
· N2O L.P. DL4 · · Air8 L.P. DL5 · DH6
· Air8 H.P. DH5 · CO2 H.P. DH6 · DL6
· Air8 L.P. DL5 · CO2 L.P. DL6 ·
· EARTH · EARTH
4 6 4 6 4 6 400 300 10
2 8 2 8 2 8 500 200 5
0 10 0 10 0 10 600 15 4 6 4 6
0 16 2 8 2 8
100 4 6 4 6 400 10
Air-8 00 2 8 2 8 500 0 10 5 0 10
700 300
760 mmHg 0 10 0 10 600 200 15
0 16
100
Air-8 00
700
760 mmHg
Oxygen - O2 A ir N itr ous Ox ide V a c uum
N 2O Vac
Oxygen - O2 A ir V a c uum N itr ous Ox ide Ca rbon Diox ide
Vac N 2O CO2
700 825 90
9
KIB GS 5 KIB GS 6
G. Samaras S.A. MEDICAL GAS SYSTEMS 59
3.5 ALARM SYSTEMS FOR MEDICAL GAS PANELS
The medical gases alarm panels are designed to monitor remotely the signals of medical gases installations with uninterrupted visual
and sound notice to technical service personnel according to EN ISO 7396-1 and HTM 02-01.
LOX Tank
O2 Cylinder Station
N2O Cylinder Station Vacuum CO2 Cylinder Station
Central System
SYSTEM
ACT GAS O2 Air Vac N2O Air800 CO2
LINK Normal
SILENCE
MENU TEST
HP
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
O2 Generator
SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal
LINK
SILENCE MENU TEST
HP
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal
LINK
SILENCE MENU TEST
HP
LP SYSTEM
ACT
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 LINK
SILENCE
GAS O2 Air Vac N2O Air800 CO2
Normal
MENU TEST
HP
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
SYSTEM ΜΟ2CSS O2 GENERATOR
ACT
LINK INLET O2 GENERATOR O2 O2 O2
SILENCE AIR VESSEL PURITY NET
RUN STAND-BY PRESS. SUPPLY
PRESS.
O2 AUX Cylinder Station MENU TEST FAULT SERVICE N2O AUX Cylinder Station N2 Cylinder Station
ALARM / FAULT
q +30 2310 463388 http//www.gsamaras.gr [email protected] ΜΟ2CSS FILTER DRYER DEW POINT CO CO2 TEMP.
Nurse Call System with Voice Communication Central Medical Gas Alarm Panel
Central Nurse Call Station CONTROL & ALARM PANEL FOR MEDICAL STATION
SOURCE 1
SOURCE 2
SOURCE 3
NET
TCP/IP LS: Voltage FAULT/ 2nd STAGE
Control SERVICE ALARM PANEL
FILTERS
q +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP C1
LAN Ethernet Network UTP CAT 5e Local PC Touch Screen
60 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Alarm Systems
HTM02-01 ENISO7396-1 TCP/IP ICU
5 Gas Reducer Panel 3 Gas ASVU
Industrial Air Medical Air Cylinder Station AGSS
System
SYSTEM GAS O2 Air Vac N2O Air800 CO2 5 Gas ASVU OPT
Medical Air ACT Normal OPT Panel
System LINK
SILENCE MENU TEST
HP
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal
LINK
SILENCE MENU TEST
HP
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
SYSTEM 3 Gas
ACT Reducer Panel
LINK
SILENCE GAS O2 Air Vac N2O Air800 CO2
Normal
MENU TEST
HP Normal Care BHU
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
CONTROL & ALARM PANEL FOR MEDICAL STATION SYSTEM GAS O2 Air Vac N2O Air800 CO2
ACT Normal
LINK
SILENCE MENU TEST
HP
LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
SOURCE 1
SOURCE 2
SOURCE 3 SYSTEM
ACT
NET LINK GAS O2 Air Vac N2O Air800 CO2
SILENCE Normal
TCP/IP LS: Voltage FAULT/ 2nd STAGE
Control SERVICE ALARM PANEL
FILTERS MENU TEST
HP
q +30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP C1
Medical Air AUX Cylinder Station LP
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6
Pendant
Wired gateway www.medimote.gr
GSM gateway (optional)
MEDIMOTE II Portal User Alerts
Medical devices monitoring
E-mail
Data I/O Enterprise loT Cloud-Platform E-mail
Web- E-mail
Telemetry Service
Comm-Server SMS
Alerting www.medimote.gr loT Front-
module Telemetry Portal API/ end
SDK Cloud
SMS / Application
E-mail
Gateway Scalable
Cloud DB
Local DB
(backup & archiving)
G. Samaras S.A. MEDICAL GAS SYSTEMS 61
PRODUCT PORTFOLIO
3.5.1 Sensors DIN175301-803-A
The medical gas alarm panels are based on M12/4p
microprocessor technology to provide an Analog sensors
alarm system capable of monitoring the
complete medical gas services installed in
a hospital and transfer all the information
through internet (TCP/IP) connection to the
control room.
Digital sensor
TYPE Description Range Connection Signal Alarm limit Comments
Low High
4 bar 6 contacts 4-20mA
DIGITAL PRESSURE SWITCH NO/NC 5 bar 6 contacts 4-20mA
8 bar 6 contacts 4-20mA
PS D-2/6bar all gases /-1bar 6 contacts 4-20mA 3,2 bar 4,8 bar predefined
4-20mA 4 bar 6 bar ±20% operation pressure
PS D-4/9bar all gases -1 to 0 bar M12/4p 4-20mA 6,4 bar 9,6 bar (minor adjustment possible
0-16 bar DIN175301-803-A 400mbar using a mechanical screw)
PS D-9/15bar all gases 0-16 bar 4-20mA
0-20 bar M12/4p
PS D-1500mbar Vac 0-25 bar DIN175301-803-A /1mt cable 4-20mA
0-250 bar 4-20mA
ANALOG TRANSDUCERS 4-20mA M12/4p 4-20mA
0-1 bar DIN175301-803-A 4-20mA
PS A-1bar Vac 4-20mA
85m3/h 1/4” 4-20mA
PS A-16bar all gases 85m3/h 1/2'' 4-20mA
160m3/h 3/4” 4-20mA
PS A-16-C bar all gases 275m3/h 1'' 4-20mA User programmable Accuracy F.S.±0,5%
455m3/h 1¼”
PS A-20bar all gases 520m3/h 1½” 4-20mA
855m3/h 2”
PS A-25bar all gases 18m3/h 2” 4-20mA
72m3/h 2” 4-20mA
PS A-250bar all gases 4-20mA
DIFFERENTIAL ANALOG TRANSDUCERS 4-20mA
4-20mA
PS DA-1bar all gases 4-20mA
4-20mA
FLOW SENSORS Consumption sensor 4-20mA User programmable Accuracy ±1.5% of M.V.,
ASFL 1/4 with integrated 4-20mA ±0.05% of F.S.
ASFL 1/2 4-20mA On request:
ASFL 3/4 measuring section
ASFL 1 Special calibration via 5 point
ASFL 1¼ ISO calibration certificate
ASFL 1½
ASFL 2
ASFL 300
ASFL 1200
TEMPERATURE SENSORS
ASTP Temperature sensor -50° to +100°C User programmable <0.5% with
User programmable possible calibration
DEW POINT / RELATIVE HUMIDITY SENSORS
<0.5%
ASDP -60°C Dew Point sensor -60° to +60°C with possible
-40° to +60°C
ASDP -40°C Dew Point sensor calibration
0–100%
ASRH Relative humidity sensor
GAS SENSORS O2 (Zirconia) 0–100% / 0–96% User programmable <0.5%
O2 (Paramagnetic) 0–100% with possible
ASO2Z 0–50ppm
ASO2PP CO calibration
ASCO 0–500ppm
CO2 0–20ppm
ASCO2 NO 0–20ppm
ASNO 0–50ppm/0–100ppm
NO2
ASNO2 SO2
ASSO2
62 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Alarm Systems
3.5.2 MGSAP monitoring and alarm systems
The monitoring and alarm systems are used to provide all the important information to the control room. They indicate the pressure
level of each gas (Low, Normal, High) whereas they can supply with information about a single medical station. Moreover, they are able
to send useful data to a remote user.
3.5.2.1 Local Alarm Panel - Single Station Alarm Panel / MGSAP L6. Features: IP based
SYSTEM GAS O2 Air Vac N2O Air800 CO2 Inputs: 6 analog inputs (transducers), 10/12 • adjustable analog sensors range and type
ACT Normal digital (switches) • alarm programming through Ethernet con-
LINK
SILENCE MENU TEST Outputs: nection with an IP address
• 12 outputs digital signals used for: a) repeat- • button test and silence
HP • 230V 50Hz-60Hz power supply (double insu-
ing to second panel, b) central alarm system,
LP c) BMS of installation. lated transformers)
• built in 18 LED, 2 red LED for each gas, 1 for • alarm / events report and log file (max 200
+30 2310 463388 http//www.gsamaras.gr [email protected] MGSAP L6 high and 1 for low pressure indication and 1
green for Normal records with relative time stamp)
L6: 6 gases alarm panel. It uses: • built in buzzer for alarm signaling • editable gas names
- O2 generator • LCD display (2×16 characters) for real time • remote control and monitor of the central
- Air dryer pressure monitoring and text messages cor-
- Economizer responding to alarm conditions AGSS central units through the L6
- AGSS central station • adjustable limits and alarm messages (by user • leakage test procedures according to EN ISO
- Local pressure alarm 6 gas programming through TCP/IP web page in-
- Remote control of AGSS system terface) 7396-1
- Master controller of up to 4 stations • ability to connect to MEDIMOTE portal,
(air, vacuum, O2, generator, dryer)
providing SMS / E-mail alert
(www.medimote.gr)
Code INPUTS OUTPUTS Communication Clock Interface Battery Extra
MGSAP Analog Digital
BUTTONS operational RJ45/10T Modbus RS 232 Web Optional
L6 6 12 Silence / Base over or page input
C1 Type 15 12 Test / Return OUT LED LED Display Buzzer TCP/IP
6 GAS Ethernet RS485 yes yes
central 6 digital outputs (Double Tone 1 yes 1 1 2 digital
3 (sinking) 18 3 LCD 2×16 800/1600 Hz) (optional I/O
Alarm (Power PWM) RTC)
9×Relay LCD 4×40 1 1 yes 1 RTC yes temperat.
6 (C/NC/NO SPDT) 20 4 or touch yes sensor
Alarm panel
Main monitor web page of Local Alarm Panel
G. Samaras S.A. MEDICAL GAS SYSTEMS 63
3.5.2.2 Central Alarm Panel for Medical Gases MGSAP C1 IP based
The central alarm panel is a monitoring and alarm system of all sources and networks of
Medical gases. It’s functionality is according to EN ISO 7396-1 (EN 737-3), HTM 02.01 in-
cluding all the necessary audio-visual signals for any alarm condition. The system makes
online measurements of pressure, using analog transducers and displays them in the
built in LCD 4×40 display. The pressure measurements of medical gases are:
• O2 R/L/A cylinder, Vessel, 1st / 2nd stage network It controls: C.Air
• N2O R/L/A cylinder, 1st / 2nd stage network - Vacuum MGSAP C1
• C. Air network and Humidity - Compressed air
- All station alarm panel
• Vacuum network - Nurse-call
q +30 2310 463388 http//www.gsamaras.gr [email protected]
The visual and audible alarm signals are specified in ISO 7396-1 and are • user programmable configuration and parameter settings (code pro-
grouped in the following categories: tected area )
a) Emergency alarms (ALARM) • alarm / events / services report and log file (max 250 records with time
b) Operating alarms (PRE ALARM) - (SERVICE) stamp)
c) Information signals
• medical gases plants monitoring using graphs, that are stored in MGS
Additional major features: controller memory and they can be retrieved for further evaluation
• IP based system, remote access via Ethernet by any internet browser, by using a USB memory stick.
• Modbus TCP/IP communication includes as standard
• self test procedures and diagnostics utilities included for system in- • optional battery back up system
tegrity, communication and wiring testing • on site firmware upgrade capability via a common USB memory stick
• real time clock with battery back up and built in non volatile memory • on line remote system viewing and additional daily graphs for all net
• default values for all parameters ensures reliable operation
pressures
• water proof metal enclosure, IP 54.
• ability to connect to MEDIMOTE portal, providing SMS / E-mail alert
(www.medimote.gr)
Main monitor web page of Central Alarm Panel Statistics and graphics Configuration web page of Central Alarm Panel Limits,
Level and Type of Sensors of Alarm (Code sensitive)
Configuration web page of Local Alarm Panel Image Editor for offline simulation and configu-
Limits, Level and Type of Sensors of Alarm (Code ration of Central Alarm Panel (Code sensitive)
sensitive) through USB Image Files
64 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Alarm Systems
3.5.2.3 Remote Management System (Medimote) MGSAP G1
HTM02-01 ENISO7396-1 TCP/IP
G. Samaras S.A. telemetry system can be used to transfer data captured remotely. Any analogue signal, usually from a transducer, or
digital signal can be interfaced to the hardware. Also, digital information can be transfered through Modbus and the telemetry
system digital (GPRS) to the Web Interface.
Remote monitoring has become an essential part in everyday life. The ability to monitor, control and manage remote devices is an
important factor for companies that can’t afford equipment failure.
Remote information is transmitted via the HTTP POST protocol to a HTTP server or via TCP/UDP to a server. The data are collected in a
database and the readings for each individual station is displayed through the portal. Data is sent at a pre-defined transmission interval
via the User Interface at initial installation or from the web application remotely.
If sms alerts have been configured, a registered engineer will receive an sms/e-mail if a threshold/criteria is monitored.
MEDIMOTE II Portal medical gas devices remote monitoring User Alerts
O2 Cylinder station Data I/O Enterprise loT Cloud-Platform
O2 Generator Web-
Telemetry Service E-mail
Medical vacuum central station Comm-Server E-mail
Medical air central station E-mail
CO2 Cylinder station Wired gateway Alerting www.medimote.gr loT Front-
N2O Cylinder station GSM gateway (optional) module Telemetry Portal API/ end SMS
AGSS SDK Cloud
Adsorption dryer SMS / Application
E-mail
Gateway Scalable
Cloud DB
Local DB
(backup & archiving)
Features Receive alerts (SMS/email)
Get graphs of each device’s operation
Real time monitor of each project (hospital, clinic, department) Easy navigation
Operation 365 / 24 / 7
Real time monitor of each device (cylinder station, compressed
air station, dryer, vacuum station, agss, O2 generator, asvu, sec-
ond stage reducer panels)
www.medimote.gr
65
66 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Bed Head Units
3.6 BED HEAD UNITS
Bed head units have been created for grouping all the necessary electrical, lighting,
data, communications equipment and medical gases services and are designed to
serve:
Normal hospital care, intensive care areas, special care areas (reanimation, geriatric,
coronary, etc.), nursing home and hospice.
All models of B.H.U. are constituted of extruded aluminum profiles, stove enameled,
having different components for power mains, low and extra low voltages and for
medical gases.
G. Samaras S.A. MEDICAL GAS SYSTEMS 67
Special Infant ICU Colour selection by RAL scale
3.6.1 Wall mounted BHU
The wall-mounted Bed Head Unit is installed externally on the wall
above the patient’s bed. It provides all the necessities for the treatment
of the patient by the nurses (medical gas outlets), but also includes var-
ious features that add to the patient’s comfort during his hospitaliza-
tion, like lighting, electrical sockets and low voltage circuits (e.g.
telephone, data, nurse call etc).
I. Aluminium profiles - coloring
The bed head unit is manufactured from a special profile of aluminum
and coated with electrostatic paint.
The units are supplied in a white standard color RAL9016 or gray an-
odized. Optionally, any color of the RAL scale can be supplied too. All
G. Samaras BHU profiles are equiped also with one or more distinctive
decorative aluminium profile DR that can have any possible RAL color-
ing. This decorative aluminium small profile DR can be replaced by the
profile Type-R (rail profile add-on) for rail support system according to
DIN (25x10mm) in the profiles Alexandra-R, Theodoro-R, Kallipolis.
All units are labeled CE0653 to guarantee a high level of safety for patients and personnel.
68 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Bed Head Units
Special Infant ICU
All units are tailor-made solutions, according to each installation. The individual channels described above are closed with covers
The units can be equipped with any desirable type of electrical from aluminum profile that can be easily removed. The typical
and medical gas outlets. BHU length is about 1,80m. for normal care, if more than one bed
The available BHU models are: ELISA, KASSANDRA, THEODORO, is required then the length is multiplied by 1,80m - depending
THEODORO-R, PANORAMA, KALLIPOLIS, ALEXANDRA, ALEXAN- on the number of beds and 2,50m for special care.
DRA-R, PANDORA. Typical placement of BHU is wall-mounted and horizontal. In
The units can be either wall-mounted or suspended. The units can some cases, the same BHU profile can be placed vertical or sus-
be produced in differnt leghts up to 6 meters and one unit can pended. It is used in specific rooms where wall mounted BHU in-
serve multiple beds. The bed head units are manufactured and stallation is not possible (in cases where there are windows,
tested in accordance with standards EN ISO 7396-1, EN ISO 14971, columns or other obstacles). The suspended supply system offers
EN ISO 11197, EN793, EN 60101-1, EN 60598-1, EN 60598-2-25 a number of decisive advantages for optimum patient treatment
(lighting) and EN 12464-1. in the field of intensive care.
The BHU internally is separated in five (5) independent channels for:
• Indirect lighting, night lighting and the bodies of lightings,
ballast etc
• Lighting for reading, for examination and electric elements
(switches, sockets etc.)
• Two independent channels are used for wiring, low and high
voltage.
• Copper pipes and medical gases outlets
G. Samaras S.A. MEDICAL GAS SYSTEMS 69
138.55 111.9 185 SINGLE BED HEAD UNITS
70 visit us on www.gsamaras.gr •••• Normal care Profile “ELISA” for normal hospital care and critical area
55.2 125 Emergercy 175.1
Profile “KASSANDRA” for normal hospital care and ward areasICU
• • • 63 – 2 – 2 – – 79.6Departments/wards CCU Departments/wards
NICU
Normal care Installation options • • • 6 3+2 – 5 1 2 – – Recovery Installation options (wall mounted horizontally / ceiling suspended)
Emergercy OPT
ICU Technical data (wall mounted horizontally / ceiling suspended) Wall mounted Technical data
CCU horizontally
NICU Wall mounted
Recovery vertically
OPT Ceiling suspended
Wall mounted horizontally
horizontally Ceiling suspended
Wall mounted vertically
vertically Mounted on
Ceiling suspended vertical brackets
horizontally Embedded on
Ceiling suspended vertical brackets
vertically Maximum length
Mounted on in meters
vertical brackets No of separated
Embedded on channels
vertical brackets Rail on BHU
Maximum length Maximum medical
in meters gas pipes
No of separated AGSS pipe
channels Lighting
Rail on BHU Single trolleys
Maximum medical Pendant arms
gas pipes
AGSS pipe
Lighting
Single trolleys
Pendant arms
279.63 84.6 • 205.6 Profile “Pandora” for normal care
Profile “Pandora EX-R” for normal care
Normal care Normal care 84.6
Emergercy Emergercy
•••••• ICU Departments/wards ICU Departments/wards
CCU CCU
•• • NICU Installation options •• NICU Installation options PRODUCT PORTFOLIO
Recovery Recovery
G. Samaras S.A. MEDICAL GAS SYSTEMS 6 3+2 2 4 1 2 – – OPT Technical data (wall mounted horizontally - vertically / ceiling suspended) • 6 3+2 – 3 – 2 – – OPT Technical data Bed Head Units
Wall mounted Wall mounted
horizontally horizontally (wall mounted horizontally / ceiling suspended)
Wall mounted Wall mounted
vertically vertically
Ceiling suspended Ceiling suspended
horizontally horizontally
Ceiling suspended Ceiling suspended
vertically vertically
Mounted on Mounted on
vertical brackets vertical brackets
Embedded on Embedded on
vertical brackets vertical brackets
Maximum length Maximum length
in meters in meters
No of separated No of separated
channels channels
Rail on BHU Rail on BHU
Maximum medical Maximum medical
gas pipes gas pipes
AGSS pipe AGSS pipe
Lighting Lighting
Single trolleys Single trolleys
Pendant arms Pendant arms
71
72 visit us on www.gsamaras.gr 209.3 167.9 153.34
• • 63 – 4 1 2 – – Normal care Departments/wards • • 63 – 4 1 2 – – Normal care Departments/wards • • 63 – 4 1 2 – – Normal care Departments/wards Profile “Alexandra” for normal care
Emergercy 84.6 Emergercy Profile “Alexandra-R” for normal care Emergercy 84.6
ICU Installation options Profile “Alexandra-R-EX” for normal care ICU Installation options 84.6 ICU Installation options
CCU Technical data CCU Technical data CCU Technical data
NICU NICU NICU
Recovery Recovery Recovery
OPT OPT OPT
Wall mounted Wall mounted Wall mounted
horizontally horizontally horizontally
Wall mounted Wall mounted Wall mounted
vertically vertically vertically
Ceiling suspended Ceiling suspended Ceiling suspended
horizontally horizontally horizontally
Ceiling suspended Ceiling suspended Ceiling suspended
vertically vertically vertically
Mounted on Mounted on Mounted on
vertical brackets vertical brackets vertical brackets
Embedded on Embedded on Embedded on
vertical brackets vertical brackets vertical brackets
Maximum length Maximum length Maximum length
in meters in meters in meters
No of separated No of separated No of separated
channels channels channels
Rail on BHU Rail on BHU Rail on BHU
Maximum medical Maximum medical Maximum medical
gas pipes gas pipes gas pipes
AGSS pipe AGSS pipe AGSS pipe
Lighting Lighting Lighting
Single trolleys Single trolleys Single trolleys
Pendant arms Pendant arms Pendant arms
213.21 116.70 116.66
99 84.82 PRODUCT PORTFOLIO
129.82 Bed Head Units
94 Profile “Kallipolis” with or without rail for normal care
25 84.6
• • 63 – 4 1 2 – – Normal care Departments/wards • • 63 – 4 1 2 – – Normal care Departments/wards Profile “Kallipolis-L” with or without rail for normal care
Emergercy Installation options Profile “THEODORO-R” for intensive care, recovery and special care Emergercy Installation options
G. Samaras S.A. MEDICAL GAS SYSTEMS ICU Technical data ICU Technical data
CCU CCU
NICU NICU
Recovery Recovery
OPT OPT
Wall mounted Wall mounted
horizontally horizontally
Wall mounted Wall mounted
vertically vertically
Ceiling suspended Ceiling suspended
horizontally horizontally
Ceiling suspended Ceiling suspended
vertically vertically
Mounted on Mounted on
vertical brackets vertical brackets
Embedded on Embedded on
vertical brackets vertical brackets
Maximum length Maximum length
in meters in meters
No of separated No of separated
channels channels
Rail on BHU Rail on BHU
Maximum medical Maximum medical
gas pipes gas pipes
AGSS pipe AGSS pipe
Lighting Lighting
Single trolleys Single trolleys
Pendant arms Pendant arms
73
74 visit us on www.gsamaras.gr 271.1 233.4 COMBINATIONS OF BED HEAD UNITS
154.4 116.7 116.7 116.7 Except from the single Bed Head Units, G.SAMARAS SA also provides a variety of combinations which are designed to cover special
needs that a single profile cannot fulfill (eg 2 rails on a BHU).
129.8 129.8
84.8 84.8
25 25 25
••••• Normal care Departments/wards Normal care Alexandra + Kallipolis with one rail add-on ••••• Departments/wards Kallipolis + Kallipolis with two rails add-on
Emergercy
• Emergercy ICU •
CCU
ICU Installation options NICU Installation options
Recovery
6 2+1 1 4 1 1 – – CCU Technical data OPT 62 2 4 1 – – – Technical data
Wall mounted
NICU horizontally
Wall mounted
Recovery vertically
Ceiling suspended
OPT horizontally
Wall mounted Ceiling suspended
horizontally vertically
Wall mounted Mounted on
vertically vertical brackets
Ceiling suspended Embedded on
horizontally vertical brackets
Ceiling suspended Maximum length
vertically in meters
Mounted on No of separated
vertical brackets channels
Embedded on Rail on BHU
vertical brackets Maximum medical
Maximum length gas pipes
in meters AGSS pipe
No of separated Lighting
channels Single trolleys
Rail on BHU Pendant arms
Maximum medical
gas pipes
AGSS pipe
Lighting
Single trolleys
Pendant arms
167.9 439 154.4 322.3
116.7
167.9 154.4
129.8 PRODUCT PORTFOLIO
84.8
Bed Head Units
25 25
Alexandra + Alexandra R with one rail add-on
•••••• Normal care Departments/wards Alexandra + Kallipolis + Alexandra R with one rail add-on •••••• Normal care Departments/wards
Emergercy 129.8
• ICU • •• Emergercy 84.8
CCU
• 6 5+2 – 5 1 2 – – NICU Installation options ICU Installation options
Recovery
G. Samaras S.A. MEDICAL GAS SYSTEMS OPT Technical data 6 4+2 1 4 1 2 – – CCU Technical data
Wall mounted
horizontally NICU
Wall mounted
vertically Recovery
Ceiling suspended
horizontally OPT
Ceiling suspended Wall mounted
vertically horizontally
Mounted on Wall mounted
vertical brackets vertically
Embedded on Ceiling suspended
vertical brackets horizontally
Maximum length Ceiling suspended
in meters vertically
No of separated Mounted on
channels vertical brackets
Rail on BHU Embedded on
Maximum medical vertical brackets
gas pipes Maximum length
AGSS pipe in meters
Lighting No of separated
Single trolleys channels
Pendant arms Rail on BHU
Maximum medical
gas pipes
AGSS pipe
Lighting
Single trolleys
Pendant arms
75
VERTICAL BED HEAD UNITS 3.6.3 Power Column / Bed-side Locator
A. Power column. The power column may consist of a single or double profile. It includes
all the necessary gas and electrical outlets, as well as data and equipotential sockets. It
may also bare a rail for hanging various equipment. In case it is necessary it can include
an embedded lighting and medical gas alarm panel.
Its main advantage is that it provides a 360° access to the patient. The power column
gives to the care givers the ability to move around the bed without any obstacles and it
also provides direct access to the critical area where the head of the patient is found.
B. Bed side locator. The bed side locator is made of two different materials. A frame made
of aluminum which includes all the necessary electrical and data outlets and an internal
part made of HPL or aluminum.
It optimizes the hospital’s investment because it combines practicality and durability. Its
internal part is a hard and durable material that offers great protection to the walls from
bariatric beds and still its frame part can provide the essential to the nursing staff and
the patient electrical and data supply, by carefully placed outlets, which are protected
from damaging contacts with the bed, by having a specially designed inclined position.
It comes in various sizes in order to cover the needs of any type of bed the hospital uses
and it is very easy to install, use and clean.
C. Light. For a complete solution, bed side locators and power columns can be assisted
with a light placed on the wall behind the patient’s bed. The light can come in various
sizes and powers.
TRANSFER 150
CONNECT 125
FAULT TEST OK
POWER
SILENT
1000
Ox ygen Oxy gen C Light
0653 DIN 13260-2 0653 DIN 13260-2
Air Air
0653 DIN 13260-2 0653 DIN 13260-2
V acuum V acuum A Power column
0653 DIN 13260-2 0653 DIN 13260-2
1500
B Bed side locator
500
Power column 414 1000 150
76 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Bed Head Units
3.6.4 Kids Bed Head Units
Our kids series of bed head units is specially designed to cre-
ate a more friendly and comfortable atmosphere to our little
friends. At the same time they cover all usual equipment of
a typical bed head unit such as medical gas outlets, electri-
cal sockets, lighting, data etc.
G.SAMARAS SA offers a various models which can cover dif-
ferent needs in horizontal or vertical layout. They are being
manufactured by extruded aluminum profiles of a great se-
lection of colors whereas the front cover with the kids theme
has the following options:
1. Direct printing on the bed head unit
2. Sticker of special design
In both options the materials that are being used are suitable for indoor use, resistant in all typical hospital detergents and disinfec-
tants and guarantee the long life of the graphics.
All bed head units are being designed and produced according to the specifications of each project there are lots of graphics available
for your choice!
G. Samaras S.A. MEDICAL GAS SYSTEMS 77
CEILING SUSPENDED BED HEAD UNITS
ATHOS series
For special placement, when the bed head unit cannot be placed on the wall, it can be otherwise suspended from the roof by a special
aluminium “BR“ profile or hung on the “ΒR“ profiles which are placed from the roof to the floor. Gases and electrical connections are
made through the “BR“ profile. There are three versions: for small loads of trolley (≤80kg), for heavy loads of trolley (80-150kg) and extra
heavy load (>150kg). Those solutions can be used in ICU instead of using ceiling pendant arms.
Light load trolley version Ι
Ceiling suspended “PANORAMA” with trolleys, light-load Version I Installation options Technical data
100 Departments/wards
230
•••
145 • 63 1 22–
44
Normal care
Emergercy
ICU
CCU
NICU
Recovery
OPT
Wall mounted
horizontally
Wall mounted
vertically
Ceiling suspended
horizontally
Ceiling suspended
vertically
Mounted on
vertical brackets
Embedded on
vertical brackets
Maximum length
in meters
No of separated
channels
Rail on BHU
Maximum medical
gas pipes
AGSS pipe
Lighting
Single trolleys
Pendant arms
FALSE CEILING
36W or 58W
Upper view
90
Panorama + TR + BR Rear view
C ALL Di gti al Clo ck/ Tmi er Front view
C ANCEL
S ET / Ho u rs
LRige ah dt ni g
S T A R T T/ mi re
S ET / M ni ut se
S T O P/T i mer
L i hg t L- ED
Night LED 18W
Horizontal movement
300Γ
Horizontal movement
400 700
Rail support 2000
1000 700 Inox tray 400x400mm
adjustable height
4hook holder 38 38
25 Drawer with
38 inox shelf 400x400x150mm
adjustable height
Floor
78 visit us on www.gsamaras.gr
Pandora + Pandora + BR 205.6 Ceiling suspended “Double PANDORA” with trolleys, heavy-load, Version II Heavy load trolley version ΙΙ
100 Departments/wards
Normal care
285
Emergercy
•••
ICU
150 100 200 • 66 – 2 – 2 2 – Installation options PRODUCT PORTFOLIO
500 CCU
G. Samaras S.A. MEDICAL GAS SYSTEMS 1600 Bed Head Units
NICU
Floor
Recovery
1000 Monitor double arm Technical data
1100 For LCD screen 10-22". OPT
Wall mounted
2000 100 150 horizontally
Wall mounted
180 178 vertically
Ceiling suspended
3000 horizontally
Ceiling suspended
vertically
Mounted on
vertical brackets
Embedded on
vertical brackets
Maximum length
in meters
No of separated
channels
Rail on BHU
Maximum medical
gas pipes
AGSS pipe
Lighting
Single trolleys
Pendant arms
79
80 visit us on www.gsamaras.gr Panorama-H + Panorama-H + BR Ceiling suspended “ATHOS” with two pendant arms, extra heavy-load, Version III Extra heavy load trolley version ΙΙΙa
Departments/wards
Normal care
100
Emergercy
45 414 45
ICU
• • •150
CCU
• Installation options
NICU
2× 38 tubes
Recovery
Floor 62
OPT
Wall mounted 1–2 Technical data
horizontally
2× 38 tubes Wall mounted
vertically
Ceiling suspended
horizontally
Ceiling suspended
vertically
Mounted on
vertical brackets
Embedded on
vertical brackets
Maximum length
in meters
No of separated
channels
Rail on BHU
Maximum medical
gas pipes
AGSS pipe
Lighting
Single trolleys
2000
3000 500 Pendant arms
Pandora + Pandora + BR Ceiling suspended “Double PANDORA” or “Double PANORAMA-H”205.6 Extra heavy load trolley version ΙΙΙb
100 Departments/wards
Normal care
387 Emergercy
ICU
••• CCU
NICU
• 66 – 2 – 2 – 2 Recovery Installation options PRODUCT PORTFOLIO
OPT
G. Samaras S.A. MEDICAL GAS SYSTEMS Wall mounted Technical data Bed Head Units
horizontally
Wall mounted
vertically
Ceiling suspended
horizontally
Ceiling suspended
vertically
Mounted on
vertical brackets
Embedded on
vertical brackets
Maximum length
in meters
No of separated
channels
Rail on BHU
Maximum medical
gas pipes
AGSS pipe
Lighting
Single trolleys
Pendant arms
81
ROUND - BRIDGE BED HEAD UNITS
AEGEAN series
Bridge Bed Head Unit is an alternative solution for operation theaters instead of ceiling pendants. It is an ideal solution to be used in com-
bination with laminar flow installation. Laminar flow ventilation is used in modern operating theatres to reduce the number of infective or-
ganisms present in the air, which may lead to post-operative wound infection. The bridge Bed Head Unit can also provide easy access to
the various instruments that are needed during an operation, by hanging trolleys that can move along the four sides of the construction.
e ri u itro us O xid e
0 6 53
0 6 53
0 6 53
0 6 53
0 6 53
0 6 53 e
ir
0 6 53 u
0 653
3000 Alluminum Rail 25×10mm
CEILING Β O xy ge n VacA ri V ac u um N itr o us O xide A ir 8 0 0
M16 0 6 53
1400 0 653
0 6 53
FALSE CEILING 0 6 53
0 6 53
0 6 53
M16 M16 500 O A V N Sc G
1400
P R E PAR ATION S C R UB -UP
3000 Alluminum Rail 25×10mm
900
A O xygen A ri V ac u um Nitro us O xid e
BACK 300 300
0 6 53
0 6 53
0 6 53
0 6 53
0 6 53
900 300 300 Electrical Cables A O O A A V V N Sc
3000 3000 45 ∅38 ∅38 O A V N A8 Sc
414
C OAV
3000 Alluminum Rail 25x10mm N A8 Sc
FRONT 3500
V ac u um A ir 800 V ac u um A ir 8 0 0 DB
0 6 53 O P E R AT I O N
0 653 T H E AT E RV V A8 A8
0 6 53
0 6 53 C Electrical Cables
O x y ge n0 6 53 C
A ir E QUIP .
0 6 53 OAV
V ac u um N A8 Sc H
330°0 653
1850 ∅38 ∅38
330° 3000
D A ir 80 0 Nitro us O xide V ac u um A ri O xygen
0 653
0 6 53
0 6 53
0 6 53
0 6 53
0 653
FROM Pipeline Gas outlets
NETWORK
O2 O O2
A LOCAL ALARM O2 ∅15 Air: A Air
PANEL Air: ∅15 Vac: V Vac
Vac: ∅22 N2O: N N2O
N2O: ∅12 Air 800: A8 Air 800
Air 800: ∅18 AGSS: Sc AGSS
AGSS: ∅22
DIR TY
C OR R IDOR
e ri u itr o us O xide i
0 6 53 0 6 53 0 6 53 0 6 53
0 653
PANORAMA
BHU room 0 6 53 Equipment per bed Lighting Trolley
description Data RJ45 Direct Night In- Equipment
BHU desription PANDORA Medical gas outlets* Electrical
sockets ΕQ cat6 direct
Bed Length Rail Vertical Normal Generator 18 W 36W Trolley Shelf Drawer
Index Room (pc.) (m) on brackets Extra profile Ο2 Αir Vac N2O AGSS 800 UPS UPS EQ Data Voice or 5W or w.Ø38 Ø38 4-hook InfusionMonitor Ø38
BHU (pcs) LED LED 58 W tubes mount holder rod arm mount
1 OPT (Operation Au i 3,80 • • Yesu i 2 0 6 53 0 6 53 Horizontal rail 2 2 2 11– 88 41 ––– 1 1 2 1 –1 –
0 6 53
0 653
theater B 3,80 • • Yes 2 for trolley/ 1 1 1 1 1 1 8 8 4 1 – – – 1 1 1 – – – 1
Round BHU C 3,80 • • Yes 2 Profile BR for brackets – – 2 – – 2 8 8 4 1 – – – 1 – – – – – –
solution) D 3,80 • • Yes 2 /Ø38 tubes 1 1 1 1 1 1 8 8 4 1 – – – 1 – – – – – –
2 OPT (Operation A 3,80 •• Yes 2 Horizontal rail 2 2 2 1 1– 8 8 41 ––– 1 1 2 1 –1 –
theater B 3,80i itrousOxide • u• Yesri e 2 for trolley/ 1 1 1 1 1 1 8 8 41 ––– 1 1 1– –– 1
0 653 3,80 0 6 53 •• 0 6 53 Yes 0 653 2 1 1 1 1 8 8 41 ––– 1 ––– –––
solution Π-type) D 0 6 53 0 6 53
Ø38 tubes 11
82 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Bed Head Units
3.6.7 Aluminum Structural Framing - BR Profile 100
100
BR profile is heavy profile made of thick (up to 7cm) aluminum which comes either elec-
trostatically painted or anodized. Profile “BR” for suspended BHU
This is a smart solution that can be used in various applications. It is mainly used in cases
where the BHU cannot be wall mounted and has to be suspended from the ceiling, but
it can also serve as support for fixing BHUs on the side of this profile. By using a number
of connectors it can virtually support any application or load.
One of the main advantages of this profile is that it combines practicality and aesthetics.
Any structure can be quickly and easily assembled and disassembled even without hav-
ing any special tools or skills. Its channels can also be used for hanging movable equip-
ment. Last but not least, every single profile is reusable and can be adjusted in order to
form a new structure according to the needs of the end user.
BR profile as BHU support
G. Samaras S.A. MEDICAL GAS SYSTEMS 83
3.6.8 COMPONENTS OF BED HEAD UNITS
Medical gas outlets
The bed head unit will be equipped with the medical gases terminal units and copper pipes connecting the BHU to the medical gas
network all in separate channels.
The medical gases terminal units are double block type, manufactured according to EN 737-1 standard and the fitting is according to
EN 737- 6 standard.
Each medical gases terminal unit is accompanied by indelible polycarbonate plate (can’t be removed) according to EN 60601-1 regu-
lations labeled with the name of medical gas, the color and the chemical symbol of corresponding gas.
The copper pipes supplying the medical gases are placed inside the unit, according to EN 13348 standard, DIN 1786 and DIN 17671,
type SF Cu / F 37, and are free of arsenic, free of oil, protected to their ends, characterized according to the regulations for use in med-
ical gas installations using silver welding of 40% content in silver, in atmosphere of neutral gas (N2). For further details, check also p.
40.
84 visit us on www.gsamaras.gr
Electrical sockets / Data sockets PRODUCT PORTFOLIO
Bed Head Units
The electrical sockets are being installed
on the Bed Head Units and on the Ceiling
Pendant Arms and play a very important
role for the medical staff and also for the
patients. Their importance is crucial be-
cause the medical team must always have
an access to a constant supply of electricity
to connect various monitors, tools and ma-
chines. The white sockets are used for nor-
mal electrical supply, the green for supply
from generator and the red for supply from
UPS. Various types of electrical sockets
could be installed according to different
norms which are posed in each country.
Moreover, special needs (with led indica-
tor, with cap, etc ) may be covered.
The Equipotential sockets are being placed
close to the electrical sockets to protect
the users of various machines and tools
from static.
The Data sockets provide to the users the
ability to have access through them to a
network cabling for data transfer. They are
suitable for connection with telephones,
monitors, etc.
Electrical socket installed on BHU with frame (colored or not), and without frame. British standard switched Equipotential sockets EQ DIN
Lighting system G. Samaras S.A. MEDICAL GAS SYSTEMS 85
Each B.H.U. usually includes the following lighting components:
• General lighting (indirect) with one or more fluorescent lamp of 36 or 58W
/ 220V operated from a switch placed at room’s entrance.
• Reading lighting (direct) with one or more fluorescent lamp of 1x18W / 220V
or LED operated from a nurse call hand set.
• Night Lighting 5W / 220V with LED operated from a switch on the BHU or
from a central position in the nurses station.
• Examination light (direct) with one or more fluorescent lamps control on
the BHU
All ballasts are electronic, made by Osram. All fluorescent lamps are made
by Osram too.
All light equipment is installed and protected by a transparent polycarbon-
ate accompanied with aluminum reflectors.
85 visit us on www.gsamaras.gr
Typical BHU Lights Color Temperature RL: Reading light, GL: General light, NL: Night light
827, 2700°K 830, 3000°K 840, 4000°K
(INTERNA) (Warm white) (Cool white)
High quality Electronic Control Gears Lamp Code Power 1350 lm Luminous flux 1350 lm Voltage Energy Average Length
for T5/T8/Dulux lamps Type Technology L18W 18W 1350 lm 1350 lm 1350 lm 230V, class lifetime L(mm)
RL Fluorescent (T8) HE14W 14W 2000 lm 1350 lm 2000 lm 50/60Hz 20.000 hrs
Powered by OSRAM HO24W 24W 1200 lm 2000 lm 1200 lm 230V, A 24.000 hrs 590
Fluorescent (T5) DL18W 18W 1800 lm 1200 lm 1800 lm 50/60Hz A 24.000 hrs 549
• Very high efficiency DL24W 24W 2900 lm 1800 lm 2900 lm A 20.000 hrs 549
• Lamp start with optimum filament pre- Compact DL36W 36W 3350 lm 2900 lm 3350 lm 230V, A 20.000 hrs 217
Fluorescent L36W 36W 5200 lm 3350 lm 5200 lm 50/60Hz A 20.000 hrs 317
heating L58W 58W 2100 lm 5200 lm 2100 lm A 20.000 hrs 411
• Automatic restart after lamp replacement (2G11) HE21W 21W 2900 lm 2100 lm 2900 lm 230V, A 20.000 hrs 1200
• Automatic shutdown of defective lamps GL Fluorescent HE28W 28W 3650 lm 2900 lm 3650 lm 50/60Hz A 24.000 hrs 1500
HE35W 35W 3500 lm 3650 lm 3500 lm A 24.000 hrs 849
and at end of life (EoL) (T8) HO39W 39W 4900 lm 3500 lm 4900 lm 230V, A 24.000 hrs 1149
• Dimming range: 1…100 % luminous flux Fluorescent HO49W 49W 5000 lm 4900 lm 5000 lm 50/60Hz A 24.000 hrs 1449
HO54W 54W 7000 lm 5000 lm 7000 lm A 24.000 hrs 849
(optional) (T5) HO80W 80W 3500 lm 7000 lm 3500 lm A 24.000 hrs 1449
• Life time: >100,000 h (for T = 65°C at Tc) DL40W 40W 4800 lm 3500 lm 4800 lm A 24.000 hrs 1149
RL/GL Compact DL55W 55W 6500 lm 4800 lm 6500 lm A 20.000 hrs 1449
Fluorescent DL80W 80W 6500 lm A 20.000 hrs 533
(2G11) A 20.000 hrs 533
A 565
Five years guarantee Approval marks:
Lighting performance according to EN 12464
LED lighting LED
The BHU can be equiped with LED lamp,
with or without including dimming capa- Typical BHU LED Lights Color Temperature RL: Reading light, GL: General light, NL: Night light
bility for reading lighting and night light.
The LED solution is enviromental friendly 830, 3000°K 840, 4000°K 855, 6500°K
and economical solution as well. (Warm white) (Cool white) (Cool daylight)
I (cd/klm) Lamp Code Power Luminous flux* Voltage Energy Average Dimensions
90° Type Technology 750 lm class lifetime L×W(mm)
11000 lm 230V, 30.000 hrs 590ר27
85 RL LED ST8V-590 8.9W 700 lm 1700 lm 800 lm 50/60Hz A 50.000 hrs 590ר27
60° LED ST8A-590 8.7W 1000 lm 2100 lm 1100 lm A+ 30.000 hrs 1200ר27
1550 lm 2500 lm 1700 lm 19.3 V A 40.000 hrs 1200ר27
170 LED ST8-HV2-1200 20 W 2000 lm 2000 lm 2100 lm 38.4 V A+ 50.000 hrs 1200ר27
255 2300 lm 2400 lm 2300 lm 35.2 V A+ 30.000 hrs 1500ר27
340 (Tubular ST8-HB2-1200 18 W 1850 lm 3400 lm 2100 lm 70.3 V A 40.000 hrs 1500ר27
2150 lm 760 lm 2400 lm 35 V A+ 50.000 hrs 1500ר27
30° GL -G13) ST8-HA2-1200 22.5 W 3100 lm 1530 lm 3400 lm 35 V A+ 50.000 hrs 280×24
Light Distribution Curve 770 lm 1400 lm 36 V A++ 50.000 hrs 560×24
ST8-HV2-1500 23 W 1480 lm 2810 lm 1040 lm 66 V A++ 50.000 hrs 280×24
I.C.U. 1360 lm 1040 lm 2080 lm 133 V A++ 50.000 hrs 560×24
ST8-HB2-1500 22 W 2790 lm 2080 lm 1260 lm A++ 50.000 hrs 280×32.6
990 lm 1260 lm A++ 50.000 hrs
ST8-HA2-1500 30.5 W 1985 lm 2230 lm A++ 560x32.6
1200 lm 4470 lm A++
LED LINEAR LLE-G3-24-280-650 5.2 W A++ 560x32.6
A++
@300mA LLE-G3-24-560-1300 10.5 W 560x20
RL/GL lm@tp=65°C LLE-G3-24-280-1250 9.6 W 1120x20
@200mA LLE-G3-24-560-2400 19.3 W
lm@tp=55°C
PLVZ2-LIN-1100-280 7.1 W
@400mA PLVZ2-LIN-2200-560 14.1 W
lm@tp=55°C
LED LINEAR PLVZ2-LIN-1300-560 9.1 W
@250mA PLFZ1-LIN-2200-560 16.7 W
lm@tp=55°C
PLFZ1-LIN-4400-560 33.4 W
Typical BHU LED Lights Color Temperature
855, 5500°K 860, 6000°K RL: Reading light, GL: General light, NL: Night light
(Cool white) (Cool white)
Lamp Energy Average Dimensions
class lifetime L×W(mm)
Type Technology Code Power Luminous flux* Voltage
T26/0.8 0.8 W 65 lm 502A/3A+60+0V+H, z A++ 15.000 hrs 63×26
ΝL LED T26/1.4 1.4 W 100 lm A++ 25.000 hrs 63×26
(E14) E14/3 3W A+ 50.000 hrs 63×26
360 lm
* Luminous flux @ tp=65ºC and If=350mA
86 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Bed Head Units
Proposed BHU configurations
BHU room Equipment per bed Lighting Nurse call Switching
description operation
BHU desription Electrical Data RJ45 Direct Night In- Direct Night Indirect
Medical gas outlets* sockets ΕQ cat6 direct Operation
ELISA
KASSANDRA
THEODORO
PANORAMA
PANORAMA-Η
PANDORA
PANDORA-R-EX
ALEXANDRA
-R / -R-EX
KALLIPOLI
Generator
UPS
Bed Length Rail Rail Normal 18 W 0.7W 36W 36W Nurse 0.7W 36W
Α/Α Room (pc.) (m) on on the Extra equipment Ο2 Αir Vac N2O AGSS supply EQ Data Voice or LED or 18W or call 18W LED or
BHU wall LED** 58 W 58 W 58 W
1 Nursery 1 1,80 • • • • • 11 11 1 1 1 1 1 Yes Yes NC Yes LS
single bed
•• •
2 Nursery 2 3,60 • • • • • 11 11 111 1 Yes Yes NC Yes LS
two bed
•• •
3 Day 1 1,80 • • • • • 11 11 1 1 1 1 1 Yes Yes NC Yes LS
Clinic
•• •
4 (AIDS, SAR) 1 1,80 • • • • • 11 11 1 1 1 1 1 Yes Yes Yes LS
•• • Yes LS
5 Artificial kidney 1 1,80 • •• 11 33 1111 1 Yes LS LS
•• • LS Yes LS
6 Delivery 1 1,80 • •• Yes 11 1 22 2111 1
••
7 ICU, CCU, High 1 2,00 • Yes Yes Digital clock - 4 4 4 88 42 11 1
Dependensy •• Horizontal rail for
unit, Isolation
• • trolley /Ø38 tubes
for instruments
8 Neonatal unit 1 2,00 • • • Yes 22 2 44 22
•• •• 22
21
9 Resuscitation 1 2,00 • Yes Yes 22 222 4 4 21
•• •• 21
11
10 Recovery 1 2,00 • • Yes 22 2 44 42 1 1
• ••
11 Preparation 1 1,00 • • Yes 11 111 2 2
• ••
12 Triage 1 1,80 • • Yes 11 1 42
• ••
13 Accident and 1 1,80 • • Yes 11 22
emergency • ••
14 Suspended for 1 2,00 • Yes Horizontal rail for 4 4 4 88 Yes Yes
special rooms (double) trolley /Ø38 tubes
for instruments
NC: Nurse Call through Relay, LS: Local Switch, DS: Door Switch, R: Rail, H: Half, EX: Εχtended NOTES:
1. There are three ways of installation: a) wall mounted, b) suspended from the ceiling (using metallic columns) and c) suspended (using metallic
*The number and the type of the medical gas outlets per bed are ac-
cording to EN ISO 7396-1 & 2, HTM 02-01 columns from ceiling to floor)
**The Bed Head Unit can be equiped with LED lamps for reading light 2.Installation height (from finishing floor)
• Single profile suggestion - Elisa, Pandora, Panorama, Pandora-R-EX profile: 1,60–1,80m lower part of BHU
• Combination profile suggestion - Alexandra-R-EX, Theodoro-R, Kallipolis profile: 1,20–1,40m lower part of BHU
- Kassandra, Alexandra, Alexandra-R profile: 1,70–1,80m lower part of BHU (when used as lighting profile with Theodoro profile)
- Rail wall-mounted 0,90m – BHU mounted on Pandora-R-EX or Theodoro-R or Alexandra-R or Kallipolis or Panorama
3.The suggested profile types are the most common and there is other solutions according to the project
G. Samaras S.A. MEDICAL GAS SYSTEMS 87
88 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Ceiling Pendant Arms
3.7 CEILING PENDANT ARMS
The ceiling pendants for special treatment rooms, are placed on the
ceiling of these rooms, such as intensive care units and operating the-
aters, above the patient’s bed or above the surgical table.
The ceiling pendant has been created for grouping all the necessary
electrical, data and medical gases services, required for use in operat-
ing theaters in anesthetic or surgical rooms and intensive care areas.
G. Samaras S.A. MEDICAL GAS SYSTEMS 89
3.7.1 Ceiling Pendant for OPT
G. Samaras S.A. ceiling pendants are manufactured and installed according to the
costumer’s specifications to suit a particular location and purpose. The installed position
ensures that the outlets can be placed immediately above the medical equipment or the
anesthetic machine, thereby removing the hazard of trailing hoses and cables.
The ceiling mounted pendant system
is manufactured totally of special
extruded anodized aluminum
profiles or stainless steel and is
electrostatic painted to any desired color.
The ceiling mounted pendant systems
are produced according to ISO 11197,
EN ISO 5359, ISO 7396-
1, ISO 7396-2, ISO
9170-1, ISO 9170-2,
EN 60601-1 standards
and they are labeled
CE0653 to guarantee
a high level of safety
for patients and
personnel.
All ceiling pendant units are Vergina III with 2 drawers, 1 shelf, 1 IVF arm and 1
consisting of the following monitor arm
main parts:
• Ceiling support system Thermi IIc with 1 drawer and 5 shelves, 1 small
cylinder base and 1 monitor arm
(tailor made depending of
Olympia 06 the actual ceiling height)
• One or two horizontal
arms (made form rein-
forced aluminum profiles
in deferent lengths)
• Vertical retractable or sta-
ble body (movement
through electrical motor
in angle or telescopically)
• Technical box (that in-
cludes instruments
shelves, drawer, rail)
• Special ⍉38 tubes sup-
ports for instrument, mon-
itors and shelves support
The available ceiling pendants models are separated in two categories: not electrically Olympia 04
driven (circling movement) and electrically driven (circling movement and movement
in the vertical axis).
90 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Ceiling Pendant Arms
I. Pendant arms Vergina
The horizontal motion is made manually with
pendant rotation ability of 330°. Two circling
movement is achieved with the help of cylin-
drical bearing cases. The arms revolve on
high quality bearings so that the technical
box can be moved very smoothly and se-
curely to any position. Horizontal rotation in
two or three axis can also be provided.
The rotation cylinder of the arm comes as
standard with pneumatic brake, for the stabi-
lization of pendant during the rotation in the
desirable place, while head cylinder uses ad-
justable mechanical brake. Pneumatic brakes
are optional and after request.
The telescopical vertical movement is electri-
cal by special actuator (Swiss made Mag-
netic) with lifting capacity from 5.000N to
8.000N/360W.
The carrying capacity depends on the config-
uration (from 80Kgr to 350Kgr).
II. Technical box Makedonia
- head of the pendant arm
In the head of the pendant and in separate
compartments, are installed the terminal
units of medical gases with the correspon-
ding manometers, the electric sockets and
EQ, while around the table exists a special
stainless rail of dimensions 25x10 mm, for the
suspension of various medical appliances
and tools.
For all units, tailor made solutions are offered
with all the necessary equipment.
The pendant can include different elements
(in number and type) depending on the de-
mand.
Thessaloniki Olympia 04
G. Samaras S.A. MEDICAL GAS SYSTEMS 91
PELLA VERGINA THERMI
without arm with one arm with two arms
Ceiling Ceiling Ceiling
cover cover cover
Bearing Regulate rotation Bearing Regulate rotation Bearing Regulate rotation
every 30° every 30° every 30°
max max
max 340° a 340° a
340° Bearing
Bearing
max
max 340° b
340° Bearing
max
340°
Pendant Arm Profile (Load capability of pendant depends on length a, b and number of arms)
VCPA-1 (max thickness: 6mm) CPA-1R (max thickness: 9,5mm) CPA-2 (max thickness: 8mm)
200 200 191
up to 6 50mm 100
100 122
Technical Box Version Ib Version II
Version Ia
Aluminium
suspension tube
185.6
Aluminium Aluminium 2×∅38 inox tubes
suspension tube suspension tube
185.6 400 Bearing
Shelf (adjustable dimensions) Aluminium
with 3-sided rails body
Bearing Bearing
6 A ir O x y g e n
80
40 120 p 0 653 EN V 737-6 EN V 737-6
psi ar 0 653
bar
0 0
O x y gen -
O2
-
6
80 A ir O x y g e n up to 6 50mm
40 120
psi p 0 653 EN V 737-6 EN V 737-6
bar ar 0 653
0
0 -
Air
A -
400
500 EN 837-1 300 V a c u um E N73 7- 1 ENV 737-6 V a c u um E N737- 1 ENV 737-6
200 500 400 73 7- 1 737- 1 0 653
600 600 - 300 0 653
100 200
700 mmHg
- -
760
100
Vacuum 700 mmHg
V ac
760
6
80 Nitrous O xide E N73 7- 1 ENV 737-6
40 120
psi 73 7- 1 0 653
bar
0 -
N itrous Oxide p
N 2O ar
0
0653 adjustable
height
Shelf with drawer (adjustable Movable shelf (adjustable
dimensions) with 2-sided rails dimensions) with 3-sided rails
Movable shelf with drawer 185.6
(adjustable dimensions) with
S Shelf (adjustable dimensions) 2-sided rails
with 3-sided rails
A ir O x y g e n
max
340° 0653 0653 0653 ENV 737-6 0653 0653 0653 0653 ENV 737-6
max m A ir O x y g e n
340°
ENV 737-6 EN V 737-6
up to 650mm V a c u um V a c u um
EN737- 1 ENV 737-6 EN737- 1 ENV 737-6
Nitrous O xide E N73 7- 1 ENV 737-6
0653
max max
340° 340°
Version IIIa Version IIIb Version IIIc
Bearing Single armed Two armed Bearing Bearing
articulated support articulated support
6
80 Monitor double arm
40 for VESA75&100
6 120 0000O x y ge n
80 psi 65 3
40 bar
00 00 0 O x y ge n
120 65 3
psi 65 3
bar
0 65 3
T len -O 2
65 3
T len -O 2
65 3
MA -4
65 3
-0.4
-8 -6 adjustable
-10 -4 height
-12 -2
-14 psi
bar
-1
0065 3 MA -4
65 3
65 3
Pneumatic
brake handle
2×∅38 tubes 1×∅38 tube 2×∅38 tubes
max max
340° 340°
Pneumatic Pneumatic
brakes button brakes button
Pneumatic
Pneumatic brakes button 2×∅38 tubes
brakes button max
340°
Version IV
400 185.6
A ir O x y g e n 6
80
0653 0653 0653 ENV 737-6 0653 0653 0653 0653 ENV 737-6 40
A ir O x y g e n up to 650mm 120
psi
ENV 737-6 ENV 737-6 bar
0
V a c u um V a c u um
O x y gen
EN737-1 ENV 737-6 EN737-1 ENV 737-6 O2
Nitrous O xide 6
80
E N73 7- 1 ENV 737-6 40
120
psi
bar
0
Air
400
500 EN 837-1 300
200
600
100
700 mmHg
760
Vacuum
V ac
6
80
40
120
psi
bar
0
N itrous Oxide
N 2O
0653
2×∅38 inox tubes
max adjustable height
340°
92 visit us on www.gsamaras.gr
3g 160 160 PRODUCT PORTFOLIO
3e 3e
Ceiling Pendant Arms
1g 2g 1e 1e 2e 2e
1e 2e 1g 1g 2g 2g PELLA E13 with electrical (telescopical) movement.
Lifting capability up to 350kg
without arm
3e 300 3g 3g Systems
300 for accessories mounting
294 300 135 135
454–604 230 300 349 349 25 M8
514–664 489–468399–639
361.5 300 549–564999–699 38 M8
1. Panorama h/q/s
2. Panorama h-ex/q/s Rail M8
225 e: electrical section For more details please 180
3g3g g: gas section ckeck the ceiling pendant arm 132.5
accessories section
1g 2g LINEAR ACTUATOR (inside the profile)
Movement: Vertical Telescopically
1g1g 2g2g Push/ pull force: 8000N / 6000N*
1e1e 2e2e Stroke length: 300×500mm
Speed at no load: 8 mm/sec
3e3e 1e 2e *Max. load for medical applications 5000N
204104 96 700
55441–4654 290
565144–671544 454–604
614–614 522–672
3. Panorama h/q/b 4. Panorama d/t
3L 4L 169.3 1g 2g
185.5
2e 1e 2e
230 96
1e 1g 1e 290
1L 2L 7. Panorama d
205.6 400
354–554
422–622
5. Pandora d 6. Tetra q
Version I Version II Version III Version IV Version V Version VI Version VII
307.5 286.3 403 204.2 234.1 286.3
209.5 209.5
175.9 124.7
175.9
209.3
OLYMPIA 06 with electrical movement. Lifting capability up to 200kg (not including technical box weight)
Version Ia Version Ib Version IIa Version IIb
Steel support tube Ceiling cover C Ceiling cover Steel support tube Ceiling cover
∅133×6mm 600×600×100mm 600×600×100mm ∅133×6mm 600×600×100mm
Pneunatic brake (& Friction) Steel support tube
Regulate rotation every30° 1000 ∅133×6mm 1000 Pneunatic brake (& Friction) 1000
Regulate rotation every30°
max Pneunatic brake (& Friction)
340° Regulate rotation every30°
Friction Friction Friction
brake brake brake
max load max load max load
250Kgr 250Kgr 250Kgr
500 500 500
max max
340° 340°
Aluminium 400 Aluminium Single armed Two armed Aluminium
suspension tube suspension tube articulated suppo articulated support suspension tube
ISO E9 6V-1ISO379-610-1 Shelf (adjustable dimensions) ISO E9 6V-1ISO379-610-1 Oxy g e n
00 with 3-sided rails 00 Gm.edSaci a lmgaarsassy stSe.m As. ISO 7E93N6V-17ISO379-6170-1
000 000Gm.edSac amgaarsassystem.. 0653 0653
s 0653 0653 0653
up to 650mm 00
Gm.edSac a mgaarsassy ste.m .
s
ISO E9 6V-1IS37O9-610-1 ISO E9 6V-1I3S7O9-610-1 Ai r ISO E793N6V7-1IS37O9-6170-1 A ir 800 ISO E793N6V7-1I3S7O9-6170-1 4 EoNxSy8g3e7n-61
ISO E9 6V-1IS37O9-610-1 ISO E9 6V-1IS37O9-610-1 Gm.edSaci a lmgaarsassy stSe.m As. Gm.edSaci a lmgaarsassy stSe.m As. 28
0 bar 10
Gm.edSac a mgaarsassy ste.m . Gm.edSac a mgaarsassy ste.m . oxSygen-
s s GM.ESDaICmALCGaLAr.2Sa,5SsYSSTE.MAS.
ar
Gm.edSac a mgaarsassy ste.m . Gm.edSac a mgaarsassy ste.m . . amar. a, s . . O xyge n oxSygen-
s s Gme. Sdicamagl aasras ysSts.eAm.s
ar
O xyge n . amar. a, s . .
Gme. Sdicamagl aasras ysSst.eAm.s
4 EoNxSy8g3e7n-61 oxSygen- oxSygen-
28
0 bar 10 bar ar
. amar. a, s . . . amar. a, s . .
GM.ESDaICmALCGaLAr.2Sa,5SsYSSTE.MAS.
I OS I9N36-1SI26O90-1702-1 0653 0653 I OS DI79N3163-1SI26O90-7102-1 I OS I9N36-1SI26O90-7102-1 G .mSdaeiacmlgaasarsssyet S.sA .
EN 737-1EN V73 7- 6 O xyge n
- - Va c uum Va c uum Gme. Scamag aasras ys . . 00 Gme. Sdicamagl aasras ysSst.eAm.s 65
E E st e s 3B
O xyge n
- - Gme. Scamag aasras ys . . Gme. Sdicamagl aasras ysSst.eAm.s : -:
E E st e s
3- 3- EN 737-1EN V73 7- 6 4 EoNxSy8g3e7n-61
28 I OS I9N36-1SI26O90-7102-1
3- 3- mGe S. cama agaasrssys te. . mGe S. cama agaasrssys te. . 0 bar 10 I OS DI79N3163-1SI26O90-7102-1 00
d s d s
0653 0653 GM.ESDaICmALCGaLAr.2Sa,5SsYSSTE.MAS.
mGe S. cama agaasrssys te. . mGe S. cama agaasrssys te. . agaasrssysStme. As. agaasrssysStme. As. Gme. Scamag aasras ys . . s I OS I9N36-1SI26O90-7102-1
d s d s Air st e
Gme. Sdicamagl aasras ysSst.eAm.s
mGe S. camal mGe S. camal 00
di di Air
Gme. Sdicamagl aasras ysSst.eAm.s
Gme. Scamag aasras ys . .
st e s
I OS I9N36-1SI26O90-7102-1 I OS DI79N3163-1SI26O90-7102-1 I OS I9N36-1SI26O90-7102-1
Gme. Scamag aasras ys . . s
st e
. .
Gme. Scamag aasras ys st e s G .mSdaeiacmlgaasarsssyet S.sA .
Shelf with drawer (adjustable adjustable I OS DI79N3163-1SI26O90-7102-1 I OS I93N6-1SI26O90-7102-1 I OS I93N6-1SI26O90-7102-1 65 : -:
dimensions) with 2-sided rails height 3B
Pneumatic Brake Gme. Scamag aasras ys . . s
UP-DOWN st e
Handle
Gme. Scamag aasras ys . .
st e s
G.SAMARAS S.A.
-0.6 -0.4
-. -. -0.8 6050004EN080337-021000 -0.2 oxSygen-
77060m0 mHg100
- -. -. ar oxSygen-
-. -. -1.0 GM.ESDaICmALCGaLAr.2Sa,5SsYSSTE.MAS. . amar. a, s . . -
- ar
mmHg -. -. . amar. a, s . .
- . M. amar. a, s . .
mmHg
- . M. amar. a, s . . G .mSdaeiacmlgaasarsssyetS.sA .
Shelf (adjustable dimensions) V acuum 65 : -:
with 3-sided rails Gme. Sdicamagl aasras ysSst.eAm.s 3B
I OS I9N36-1SI26O90-7102-1 0653 0653 I OS DI79N3163-1SI26O90-7102-1 I OS I9N36-1SI26O90-7102-1 0653 0653 I OS DI79N3163-1SI26O90-7102-1 00 I OS I9N36-1SI26O90-7102-1 I OS I9N36-1SI26O90-7102-1
00 Gme. Scamag aasras ys . . s
st e
00 00
Gme. Scamag aasras ys . . . .
st e s s s
Gme. Scamag aasras ys . Gme. Scamag aasras ys .
ts e ts e
max -
340°
max I OS I9N36-1SI26O90-7102-1 V acuum I OS DI79N3163-1SI26O90-7102-1 I OS DI79N3163-1SI26O90-7102-1 I OS I9N36-1SI26O90-1702-1 G .mSdaeiacmlgaasarsssyetS.sA .
340° Gme. Sdicamagl aasras ysSst.eAm.s
I OS I9N36-1SI26O90-7102-1 Gme. Scamag aasras ys . . s I OS I9N36-1SI26O90-7102-1 65 : -:
st e 3B
Gme. Scamag aasras ys . . s
ts e
. . . .
Gme. Scamag aasras ys st e s Gme. Scamag aasras ys st e s
2x Φ38 tubes 1x Φ38 tube 2x Φ38 tubes
max max
340° 340°
Pneumatic Pneumatic
brakes button brakes button
Pneumatic
Pneumatic brakes button
brakes button
Version IIc Version III Olympia 06D (double arm)
Steel support tube Ceiling cover Steel support tube Ceiling cover
∅133×6mm 600×600×100mm ∅133×6mm 600×600×100mm
Pneunatic brake (& Friction) Pneunatic brake (& Friction)
Regulate rotation every30° 1000 Regulate rotation every30° 1000
max Friction max Friction
340° brake 340° brake
max load max load Ceiling cover 600×600×100mm
250Kgr 250Kgr Steel support tube ∅133×6mm
500 500 Height: Floor-False Ceiling
000 Pneunatic brake (& Friction) P
000 Regulate rotation every30°
Aluminium Aluminium 1000
suspension tube suspension tube a
max Pneunatic brake (& Friction)
Regulate rotation every30°
Ai r Oxy g e n ISO E9 6V-1ISO379-610-1
Gm.edSaci a lmgaarsassy steSm. As. ISO E9 6V-1IS37O9-610-1
ISO 7E93N6V-17ISO379-6170-1 340°Gm.edSaca
ISO E793N6V7-1I3S7O9-6170-1
0653 0653 0653 mgaarsassy stem. . Gm.edSac a mgaarsassy ste.m .
0653 0653 0653 s s
Gm.edSaci a lmgaarsassy steS.m A.
s
Monitor double arm Ai r Oxy g e n up to 650mm ISO E9 6V-1ISO379-610-1 Friction
for VESA75&100 Gm.edSaci a lmgaarsassy steSm. As. ISO 7E93N6V-17ISO379-6170-1 ISO E9 6V-1I3S7O9-610-1 brake
ISO E793N6V7-1I3SO7 9-6170-1
Gm.edSac a mgaarsassy stem. . Gm.edSac a mgaarsassy stem. .
s s
Gm.edSaci a lmgaarsassy steSm. A.
s
Oxy g e n Va c uum Va c uum - - max load
E E 250Kgr
G .mSdaeiacmlgaasarsssyetmS.sA . EN 737-1EN V73 7- 6 3- 3-
0 EN 737-1EN V73 7- 6
G .mSdaeiacmlgaasarsssyet S.sA . mGe .S cma agaasrssys te. . mGe S. cma agaasrssys te. .
d a s d a s
65 BBS SE5N 678327:11-:9198998 mGe S. cmaal agaasrssysStme. As. mGe S. cmaal agaasrssysStme. As.
3 di di
65 : -:
3B
Oxy g e n Pneumatic Brake 500
UP-DOWN
G .mSdaeiacmlgaasarsssyet S.sA . G .mSdaeiacmlgaasarsssyetmS.sA . Handle
0 2×∅38 inox tubes
65 BBS SE5N 678327:11-:9198998 max
3 340°
65 : -: G.SAMARAS S.A.
3B
max
MA -4 340° Aluminium
suspension tube
- G .mSdaeiacmlgaasarsssyetmS.sA . adjustable height
0 max
G .mSdaeiacmlgaasarsssyetS.sA . 65 BBS SE5N 678327:11-:9198998 340°
3
65 : -:
3B
MA -4
- G .mSdaeiacmlgaasarsssyetmS.sA .
0
G .mSdaeiacmlgaasarsssyetS.sA . 65 BBS SE5N 678327:11-:9198998
3
65 : -:
3B
Pneumatic
brake handle
G. Samaras S.A. MEDICAL GAS SYSTEMS 93
2×∅38 tubes
max
340°
PRODUCT PORTFOLIO
Ceiling Pendant Arms
PROPOSALS FOR VARIOUS USES
AnesthesiologistUse Type / Version Electrical Telescopical Elevation Load Terminal units* UPS Optional equipment
Rail on Vertical vertical electrical ability ability Ο2 Αir4 Vac N2O Air8 AGSS CΟ2/N2 Gen Tube M8 Shelf
PELLA Ia,b /II Arms pendant movement movement movement (kgr) (kgr) 4 EQ Data Ø38 rail support drawer
PELLA IIIa,b,c / IV 222 1 – 1 – 4 4
VERGINA Ia,b / II 0 No No No No – 250 222 1 – 1 – 4 4 3 2 Yes Yes No
VERGINA IIIa,b,c / ΙV 0 No No No No – 250 222 1 – 1 – 4 4 3 2 Yes Yes No
OLYMPIA 06 Ia,b / IIa,b,c 1 Yes No No No – 250 222 1 – 1 – 4 4 3 2 Yes Yes Yes
THESSALONIKI I 1 Yes No No No – 250 111 1 – 1 – 4 4 3 2 Yes Yes Yes
THERMI Ia,b / II 1 Yes Yes Yes Yes 150 150 222 1 – 1 – 4 4 3 2 Yes Yes Yes
THERMI IIIa,b,c / ΙV 1 Yes Yes No Yes 450 350 222 1 – 1 – 4 4 3 2 Yes Yes Yes
THESSALONIKI I 2 Yes No No No – 200 222 1 – 1 – 4 4 3 2 Yes Yes Yes
THESSALONIKI II 2 Yes No No No – 200 222 1 – 1 – 4 4 3 2 Yes Yes Yes
1 Yes Yes No Yes 350 400 222 1 – 1 – 4 3 2 Yes Yes Yes
2 Yes Yes No Yes 250 280 3 2 Yes Yes Yes
OLYMPIA 04 Ia / ΙΙa 1 Yes Yes No Yes 300 300 1 1 1 – 1 – – 4 4 3 2 Yes Yes Yes
Hemodynamic Endoscopy Surgeon OLYMPIA 06 Ia,b / IIa,b,c 1 Yes Yes Yes No 250 250 1 1 1 – 1 – – 4 4 3 2 Yes Yes Yes
OLYMPIA 04 Ιb / IIb 2 Yes Yes Yes Yes 250 250 1 1 1 – 1 – – 4 4 3 2 Yes Yes Yes
OLYMPIA 06D 2 Yes Yes Yes No 200 200 1 1 1 – 1 – – 4 4 3 2 Yes Yes Yes
VERGINA II / IIIa,b,c / ΙV 1 Yes No No No – 250 1 1 1 – 1 – 1 4 4 3 2 Yes Yes Yes
THERMI II / IIIa,b,c / ΙV 2 Yes No No No – 200 1 1 1 – 1 – 1 4 4 3 2 Yes Yes Yes
VERGINA Ia,b / II 1 Yes No No No – 250 2 2 2 1 1 1 – 4 4 3 2 Yes Yes Yes
OLYMPIA 04 Ιa / IIa 1 Yes Yes No Yes 300 300 1 1 1 1 1 1 – 4 4 4 2 Yes Yes Yes
OLYMPIA 04 Ib / IIb 2 Yes Yes No Yes 250 250 1 1 1 1 1 1 – 4 4 4 2 Yes Yes Yes
OLYMPIA 06D 2 Yes Yes Yes No 200 200 1 1 1 1 1 1 – 4 4 4 2 Yes Yes Yes
*The number and the type of the medical gas outlets are according to EN ISO 7396-1 & 2, HTM 02-01
Ceiling Pendant Arm Accessories
Shelves and drawers 38 38 38 38 Rails
A A
A A
3 4 38
A A+4(mm) A+4(mm)
13
1 238 Rail 25×10mm, 38 mtd
96/160/225mm with 4hooks
B C
B A
38
C
B 14 Rail 25×10mm, 38 mtd
B
B
B
A A A A Monitor arms
Shelf, 1×38 mtd Shelf, 38 mtd with 3 sided rails 25×0mm Shelf, 38 mtd with 3 sided rails 25×10mm
up to 10 kgrs Shelf, M8 rail mtd with 3 sided rails 25×10mm up to 20 kgrs (with two pneumatic brakes and handle buttons) 15
up to 50 kgrs
38 A 38 7 453 178
38 A 38 180
5 A 8 387
6
A+4(mm) 96/160/225mm 315
A+4(mm) C+70mm 420 16
140 38
38
B B
B B
B
B
A A A 453
C C C Monitor double arm for VESA75&100 Monitor double arm for VESA75&100
Shelf with drawer, M8 rail mtd with 2 sided rails 25×10mm For LCD screen 10-24” For LCD screen 17-22”
Shelf with drawer, 38 mtd with 2 sided rails 25×10mm Shelf with drawer, 38 mtd with 2 sided rails 25×10mm Shelf with ABS drawer, 38 mtd with 2 sided rails 25×10mm Vertical rotation of head: +/- 80° Vertical rotation of head: +/- 80°
(with two pneumatic brakes and handle buttons) Horizontal rotation of head: +/- 110° Horizontal rotation of head: +/- 110°
Maximum load 15kgr
IV poles
Examination lights
9
10 B 11 12
A
38 A 1× Ø16/25 1× Ø16/25 17 18
Single articulated support 38 IV pole with 2/4/6 hooks IV pole with 2/4/6 hooks
for IV pole Double articulated support
for IV pole B 38 A
38 38 A Single armed articulated support
16/25
Two armed articulated support
1× Ø16/25 for IV pole with 2/4/6 hooks 1000
C
D
C
C
25
3×LED lights: 4,2W 12V 3×LED lights: 4,2W 12V
35.000 lux at 50cm 35.000 lux at 50cm
13.000 lux at 100cm 13.000 lux at 100cm
Ø38 mtd Rail mtd
38
16/25
1× 16/25 IV pole
16/25
1× Ø16/25 for IV pole with 2/4/6 hooks
G. Samaras S.A. MEDICAL GAS SYSTEMS 95
Βearings - braking system - pneumatic brakes
In each ceiling pendant arm, a bearing with break system is being used. The brake
system can either be with friction or pneumatic using instrumental air to operate.
Both systems ensure the stability and unobstructed movement of the pendant.
Rubber brake system Support body Upper sliding part Cover Bearing Pneumatic brake Friction brake
Bumpers Handle
Plastic bumpers avail- - upward movement
able in blue (RAL 5005), - downward movement
grey (RAL 7035) or - 1st brake (green)
white colour (RAL 9016) - 2nd brake (red)
Plastic handles available in blue (RAL
5005), grey (RAL 7035) or white colour
(RAL 9016)
Proposed positioning of pendant arms, according to OPT usage* Operation Theater (OPT)
PENDANT TYPE 1
1a 1b
OPT usage Anesthesiologist Main surgeon 2nd surgeon
General "1" 34
General "2" 1a 2b 3 2a 2b
Thorax - Cardiac
Otrhopaedic - Trauma "1" 1b 2a 4
Otrhopaedic - Trauma "2"
Neurosurgery 1a 3 2b
(with microscope)
Neurosurgery (robotic) 1a 2b –
Opthalmological - ENT
(with microscope) 1b 2a –
Obstetrics - Maternity "1"
Obstetrics - Maternity "2" 1a 4 –
Urology 1a 2a 4
Paediatric 1b 1a –
Endoscopy
1a 2b 3 (laparoscopy)
1b 2a 4 (laparoscopy)
1a 4 –
1a or 1b 3 or 4 –
Positioning and placement of CP in the OPT
Usually in each OPT we install one pendant arm to be used by the surgeon. This pendant is called Primary S1 and its role is to provide
the surgeon with all the necessary gases and electrical power. This pendant is typically motorized and equipped with 38 side tubes
supporting monitor and instrument shelves. The most commonly used type of pendant is OLYMPIA 06/04.
The OPT is also equipped with a second pendant used by the anesthesiologist. This pendant can either be with or without motorized
movement. The most commonly type of ceiling pendant used in this case is Pella E13 / Thessaloniki E with movement, or Thermi /
Vergina without movement.
In some cases, for the better support of the OPT’s requirements, a third pendant is being installed, which supports mainly the surgeon.
This pendant is optional and is called secondary S2 and can be motorized or non-motorized as well.
All pendants may consist of one or two arms depending on the needs of the OPT. Furthermore, all the equipment installed on them
may differ. The following table describes our proposition for the most appropriate configuration of each type of pendant arm:
On each ceiling pendant various equipment can be mounted using 38 support tubes as shown in section 3.7.3.
Positioning of the pendant arms is decided according to OPT usage.
96 visit us on www.gsamaras.gr
PRODUCT PORTFOLIO
Ceiling Pendant Arms
Typical lay-out of OPT with ceiling pendants
An indicative positioning of the pendants, Index Description Model Reference page
for optimal ergonomic use of the OPT, is A KIB GS 5: 58
proposed in the following table and layout. B ASVU with Alarm Panel (O2-N2O-Vac-Air-Air800) 48
In the detailed layout of the OPT with ceil- C or reducer panel PG EX: (O2-Air-Vac-Air800) 100
ing pendants and in the index below, all D Including the alarm panels 92
the various parts of a typical OPT can be E Gas Outlets and control of AGSS 92
found along with the corresponding pages F Primary main surgeon 92
of the respective equipment. G Control OPT Panel pendant arm 73
It is to be noticed that each critical area, H placed internal in the OPT Anesthesiologist 101
like an OPT, is considered to be individual pendant arm
area with its own control unit for medical I Surgeon Ceiling Secondary pendant 107
gases and electrical supply. The control J Pendant S1 arm (optional) 103
unit of the gases can either be a reducer THEODORO-R
panel or an AVSU box. For the electrical Anesthesiologist
supply a control panel and electrical board Ceiling Pendant LED
are used, according to 3.8.
In the OPT, apart from the gas outlets in- Surgeon S2
stalled in each ceiling pendant, usually Ceiling Pendant
there is a second set of wall-mounted gas
outlets mainly for security reasons in case Bed Head Unit (BHU)
of ceiling pendant failure, but also for test- preparation
ing the various equipment before being
used. External electrical power
control panel and
transformer IPS/ UPS 6kVA
OPT lights
Scrub-up
O A V N Sc G S C R UB -UP
PR E PAR ATION J
O P E R AT I O N O A V N A8 Sc
T H E AT E R Sc
N
E V
I A
O
F LOCAL ALARM
B PANEL
&
D
AGSS ALARM
PANEL
O A V A8 C
O A V A8
O EQUIP.
A
V
A8
FROM P ipe lin e H
NETWORK O2 Gas outlets
Air: O O2
A LOCAL ALARM O2 ∅15 Vac: A Air
Air: ∅15 N2O: V Vac
PANEL Vac: ∅22 Air 800: N N2O
AGSS: A8 Air 800
N2O: ∅12 Sc AGSS
Air 800: ∅18
AGSS: ∅22 DIRTY
CORRIDOR
G. Samaras S.A. MEDICAL GAS SYSTEMS 97
Typical ICU lay-out with ceiling pendants Type “Makedonia”
In ICUs, for reasons of ergonomics, instead Index Description Model Reference page
of using wall-mounted BHU or ceiling sus- A ASVU with Alarm Panel KIB GS 5:
pended BHU (like ATHOS Series), a set of or reducer panel (O2-N2O-Vac-Air-Air800) 59
ceiling pendant arm (Type Makedonia) can B Makedonia type CP dry side CP 94
be used as alternative solution. C Makedonia type CP wet side CP 94
D Scrub-up 103
The G. Samaras constellation pendant
system has a range of service pendants Ceiling Pendant Arm
that are made up of several key ele- MAKEDONIA I.C.U.
ments:
O2: ∅12
• Ceiling Support system, specifically de- Air: ∅12
signed and manufactured to suit the con- Vac: ∅15
ditions in the chosen location.
OAV
• Horizontal arm assembly, which can be x4 x4 x4
rigid or articulated as required, with
lengths to suit the service requirements. WET side DRY side
• Service head containing all electro me- C B
chanical outlets
0 653 0653 10 DIN132 60-2
• Support tubes to carry additional shelves, 5
drawers and equipment. DI N132 60-2
15
IP 44 IP 44 0
IP 44 IP 44 O x ygen
0 653 O x ygen DIN13 2 60-2
0 653 10 DIN132 60-2
5
IP 44 IP 44 0 653 0 653 DIN132 60-2
IP 44 IP 44 15
0
Air
Air
E N 83 7-1
Vac uum
Vac uum
DIN13 2 60-2
I.C.U.
D
ASVU
ASVU box 3 GASES: EARTH 230V 50/60Hz CORRIDOR O2: ∅12 FROM
O2, AIR, VAC 1x 4mm2 3x2,50mm2 Air: ∅12 NETWORK
O2 Pipeline Vac: ∅15
O2 AIR VAC Air Pipeline
A Vac Pipeline
MEDICAL GAS ALARM
POWER MEDICAL GAS PRESSURE
Link
ACT O2 Vac
N2O Air
LP HP O2
N 2O
350 10E N 837-1 10E N 837-1 400 Vac O2 outlet O
5 5 500 EN 837-1 300 Air Air outlet A
0653Air-800 Vac outlet V
EN 737-3/ EN ISO 7396-11515200
0 0 600 SILENCE TEST
Oxy ge n MA -4 100
700 mmHg
760
B S 568 2:1998 P .O. Bo x 6 0 1 78 -G R 5 70 01 Thermi
0 653 The ssalon iki - Greece
B S 5682:1998 Tel.: +30 231 0 46 3 38 8 - Fax: +30 231 0 464 570
0 6 53 h ttp://www.g-sa ma ra s.gr - e ma il:info@g-sa maras.gr
90 650
Macedonia
98 visit us on www.gsamaras.gr