The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by majeed.sap, 2017-07-24 07:22:34

Jasen - Steel Windoor

STEEL SYSTEMS VISS FAÇADES 15





Variante aches Deckprol 50 mm Variante aches Deckprol 60 mm A-A









76.115 76.115 76.115
Variante aches Deckprol 50 mm Variante aches Deckprol 60 mm A-A







76.115 76.115 76.115









B-B





5 5
B-B
76.115 76.115 76.115



5 5
76.115 76.115 76.115
Variante VISS Linea lasergeschweisst





Variante VISS Linea lasergeschweisst

205
175
145
205
175
145


A A



A B A B


B B

16 STEEL SYSTEMS VISS FAÇADES















Example of VISS roof glazing
B-B
B-B





A-A B-B
A-A
20.270
20.270

A-A

20.270
28 28
28 28



76.694
28
28 28
76.694
28


76.694
28


































B
A
B
A
A
A
B
A

A
B
B




B

A-A
20.270 B-B
STEEL SYSTEMS VISS FAÇADES 17






28 28






76.694
28





B-B






A-A

20.270







28 28




76.694
28



















B
A

A










B





B
A
A








B

18 STEEL SYSTEMS VISS FAÇADES









B-B


A-A (Schweissbolzen)
B-B
Example of VISS Basic
A-A (Schweissbolzen)

B-B
B-B
A-A (Welding stud)
A-A (Schweissbolzen)
A-A (Schweissbolzen)






50 50
50 50




50 50
50 50


Variant A-A (Screw bolt)
Variante A-A (Schraubbolzen)
Variante A-A (Schraubbolzen)



Variante A-A (Schraubbolzen)
Variante A-A (Schraubbolzen)







50 50
50 50

B
50 50
50 B 50


B
B A A


A A
A A
A A
B



B
B
B

B-B Variante A-A (Schraubbolzen)
STEEL SYSTEMS VISS FAÇADES 19















Example of VISS I tra
x



B-B Variante A-A (Schraubbolzen)
A-A (Welding stud)
A-A (Schweissbolzen)





B
B-B Variante A-A (Schraubbolzen)





A A






B-B Variant A-A (Screw bolt) B
Variante A-A (Schraubbolzen)
A-A (Schweissbolzen)





B






A-A (Schweissbolzen)
A A





B
B
A-A (Schweissbolzen)





A A B







A A
B






B

20 STEEL SYSTEMS VISS FAÇADES

STEEL SYSTEMS VISS FAÇADES 21















VISS façades


Steel pro les with high structural


properties






60 60
Maximum load-bearing capacity with a
minimal number of supporting units
3
76.142 Z 280
Through the combination of new pro le additions such as Structural values
60
the VISS steel pro les, which have excellent structural
76.142 Z
properties, and the heavy-duty connecting spigot, Jansen
3 I X = 1964.8 cm 4 76.141 Z 220
60 is offering a re ned complete solution for sophisticated W X = 126.4 cm 3
façade constructions. The latter are characterised by large
76.141 Z
spans and heavy in ll units. With them, we reduce
3 I X = 1046.2 cm 4 3
architectural aesthetics, structural integrity and ef cient 280 W X = 85.2 cm 3
76.142 Z
fabrication to a common denominator.
76.140 Z
76.141 Z 220 I X = 621.5 cm 4 76.140 Z
Bene ts W X = 61.8 cm 3
76.140 Z 180 • Small edge radii 180
• Short delivery times as pro les can be obtained directly
from the warehouse
• Ef cient fabrication thanks to system pro les:
complicated welding on of screw ports not required
• Reliable surface protection inside as well as outside
through pre-galvanised pro les
• Low total weight compared to regular rectangular
hollow pro les

22 STEEL SYSTEMS VISS FAÇADES















VISS SG


All-glass façades











When building envelopes blend in with
their surroundings

The idea of transparency in a building envelope that blends
in with its surroundings can be realised harmoniously and
aesthetically with an all-glass façade. The all-glass architecture
creates a feeling of lightness and openness. Narrow internal
sightlines and the simultaneous implementation of large-scale
glass areas convey a generous sense of space.
Steel and its outstanding structural properties allow developers
and architects to turn their conception of all-glass façade
solutions into a reality simply and economically.
The VISS SG and VISS Semi SG systems can be combined with
any VISS pro le with face widths of 50 and 60 mm and with
the VISS Basic solution which can be mounted on any support.
Even roof glazing can be easily implemented in a structural
glazing style using VISS SG. This provides a large variety of
options with minimal additional components. In ll unit
thicknesses from 30 to 70 mm. Glass areas of up to 2.5 x 5.0 m




CE marking in accordance with ETAG 002
• European Technical Approval ETA 13/0015
• Thermal transmittance of U > 0.84 W/m K
2
f
• Watertightness up to class RE1200
• Air permeability up to class AE
• Resistance to wind load up to class 2 kN/m 2
• Impact resistance up to class E5/I5
• Successfully TRAV safety tested (German technical regulation
for safety barrier glazing)

STEEL SYSTEMS VISS FAÇADES 23


A-A









A-A
Example of VISS SG




A-A









B-B





B-B






B-B














B
B






B
A A
A A





A A







B

B



B

24 STEEL SYSTEMS VISS FAÇADES















VISS Fire


Fire-resistant façades











No compromise on safety

For the sensitive area of re protection, Jansen has develo-
ped the VISS Fire system – a modular façade construction for
universal use. The system is suitable for vertical façades in all
re resistance classes for interior and exterior use (E30/60/90,
EI30/60/90). All classes are also TRAV safety tested. VISS Fire
has also been approved for use with Janisol 2 and Janisol C4
re doors.
With a face width of 50 mm, re protection requirements can
be implemented discreetly and elegantly. Basic depths from
50 to 280 mm provide a whole range of structural solutions for
creating storeys of up to 5000 mm in height and of unlimited
width. The many alternatives give the developer the necessary
freedom to create attractive large areas of glazing. The Delta
and Linea load-bearing proles can be used to make an elegant
statement.



Tested in accordance with EN 1364
• Fire protection classes E30 / E60 / E90 / EI30 / EI60 / EI90
• Successfully TRAV safety tested (German technical
regulations for safety barrier glazing)
• Face width of 50 mm
• Basic depths of 50 - 280 mm
• Inll unit thicknesses of 5 - 70 mm

STEEL SYSTEMS VISS FAÇADES 25















Example of VISS Fire


B-B

B-B A-A
B-B
A-A
A-A












B-B

A-A





B


B
B


A A

A A
A A



B
B
B
B





A A








B

26 STEEL SYSTEMS VISS FAÇADES

STEEL SYSTEMS VISS FAÇADES 27















VISS RC4 burglar resistance


and break-out resistance











Maximum building protection

For the protection of luxury properties, Jansen has brought
a further development of the burglar-resistant RC3 system
solution onto the market in the shape of VISS RC4. With only
a few additional components, the tried-and-tested VISS RC3
system turns into a VISS RC4 system solution that meets
increased security requirements. Visually identical to the
standard VISS façade, the appearance of the VISS RC4
construction does not betray its burglar-resistant properties.
This means that different project requirements can be
implemented with a uniform appearance.

• VISS RC4 can be combined with the existing VISS systems in
the face widths of 50 and 60 mm
• Burglar and break-out resistance in accordance with EN 1627
• Thermal transmittance of U > 0.84 W/m K
2
f
• Watertightness class RE 1200
• Air permeability class AE
• Resistance to wind load class 2 kN/m 2
• Impact resistance class E5/I5
• VISS RC versions can be combined with the burglar-resistant
pro le solutions of the Janisol door and window systems
• Installation of double and triple glazing

28 STEEL SYSTEMS VISS FAÇADES















VISS projected top-hung window


and parallel-opening window











New opening types for increased Projected top-hung windows and parallel-
freedom of design and user comfort opening windows in all-glass look (SG)

The VISS SG projected top-hung and parallel-opening window • Projected top-hung window:
not only integrates seamlessly into the VISS SG façade – which Vent weights of up to 180 kg
allows the all-glass look to achieve its full effect – they can Max. vent size 1956 × 2456 mm (W×H)
also be installed in the standard VISS and VISS Basic systems –
for face widths of 50 mm and 60 mm. • Parallel-opening window:
The VISS projected top-hung or parallel-opening window Vent weights of up to 300 kg
can be installed as the pure SG version or alternatively as a Max. vent size 4000 × 4000 mm (W×H)
version with subtle glazing beads. The design using glazing
beads also functions as a mechanical xing for the outer • Grid area up to a maximum of 4 m²
pane, which is required in Germany, for example. • Glass thicknesses of 28 to 58 mm
• Mechanical xing of the glass to the frame – without bonding
Steel allows narrow internal sightlines to be retained • Mechanised option available through chain drive,
whilst accommodating large-scale glass areas, which convey no locking motors required
a generous sense of space. The use of double and triple
insulating glass of a thickness up to 58 mm and the option
of natural ventilation meet the increasing requirements for • CE marking in accordance with EN 14351-1
energy savings and ensure the wellbeing of users. • U values > 1.8 W/m K
2
f
• Watertightness class of up to 9A
• Air permeability of up to class 4
• Resistance to wind load up to class B/C 4

STEEL SYSTEMS VISS FAÇADES 29

30 STEEL SYSTEMS VISS FAÇADES















VISS system


Pivot door











For greater generosity across the
entire line

With the new VISS pivot door as a project-speci c solution
for oor-to-ceiling and module eld doors, the generous
lines of the VISS façade can now also be continued in
access areas. With this development, Jansen is extending
the design options for large-scale glass façades with the
addition of both a visual and functional highlight.

• Large, thermally insulated pivot door for special
applications and requirements (e.g. entrances to exhibition
halls, atria, etc.)
• Appearance identical to the VISS façade construction
• Construction principle based on the tried-and-tested
VISS façade doors
• Thermally insulated door rebate pro les available for
glass thicknesses of 27 to 42 mm
• The VISS pivot door can be both outward and inward-
opening, but can only be operated from the inside
• Dimension of the door and frame pro les can be freely
selected or speci ed in accordance with the structural
requirements
• Concealed espagnolette with lower and upper lock,
integrated in the room-side door leaf pro le
• Large selection of cover pro les allows diverse
possibilities for design

STEEL SYSTEMS VISS FAÇADES 31















Example of VISS pivot door





A-A



















50 40 50 50 40 50 50 40 50


A-A
B-B

B

50



40
A A
50

















B

50

32 STEEL SYSTEMS VISS FAÇADES















Performance characteristics


VISS façades











CE marking Thermal transmittance
Curtain wall façade tested to EN 13830. The pro le combinations were calculated
according to EN ISO 10077-2. The product
achieves UC 0.73 W/m K.
2
W


Air permeability Bullet resistance
Air permeability tested to EN 12153. Bullet resistance tested to EN 1522/1523.
The product achieves Class AE. The product achieves Class FB4 NS.





Watertightness Burglar resistance
Watertightness tested to EN 12155. Burglar resistance tested to EN 1627.
The product achieves Class RE 1200. The product achieves Class RC2/RC3/RC4.






Resistance to wind load TRAV safety tested
Resistance to wind load tested to EN 12179: The product has been tested in accordance with
– Permissible wind load 2000 Pa the German TRAV regulations (technical
– Safety load 3000 Pa regulations for the use of safety barrier glazing)
and meets the requirements of category A.


Impact resistance CWCT test
Impact resistance tested to EN 14019. Tested to the requirements of CWCT:
The product achieves Class E5 / I5.. – Air permeability/watertightness: PASS
– Permissible wind load 2400 Pa
– Safety load 3600 Pa



Sound reduction
Sound reduction tested to EN ISO 140-3.
The product achieves R = 45 dB.
W

STEEL SYSTEMS VISS FAÇADES 33















Certi cation programmes


for sustainable building











Contemporary architecture is committed to sustainability. It Timeless steel - sustainable use for generations
is not only for public buildings that the requirements in terms Steel offers an extraordinarily high recycling potential and its
of ecological standards have increased considerably in recent lifespan is unsurpassed in comparison to alternative materials.
years. The sustained building trend is also increasingly nding Windows, doors and façades made from steel and stainless
expression in relation to newbuilds, residential properties and steel full these requirements in peerless fashion and there-
renovations. fore guarantee sustainable construction and ecological use of
The focus is on efciency and awareness in the use of natu- buildings.
ral resources. Today binding evidence of the environmental
compatibility of a building is already being requested in many For increased sustainability with a prole:
project specications. In particular, the extraction of raw Environmental Product Declarations (EPDs)
materials, transport, manufacturing, fabrication, usage phase With its prole systems, Jansen makes a substantial contribu-
and recycling of a product are considered. tion to the successful certication of a building. The evidence
provided for the adherence to ecological guidelines can be
The eco-friendliness of a building is examined on the basis of used by the fabricator as the basis for obtaining their own
different certication programmes. Together with ecological manufacturer EPDs.
aspects, in most cases the topic of sustainability is also evalua-
ted in respect of sociocultural and economic requirements. Environmental Product Declarations for
• Minergie-Standard (Switzerland) steel/stainless steel prole systems
• Quality Seal of the German Sustainable Building Council With window, door and façade proles made from steel and
(DGNB stainless steel, Jansen provides for the sustainable design,
• BREEAM (Building Research Establishment Environmental installation, and, in particular, use of buildings. As a manufactu-
Assessment Method) rer of complete steel prole systems, Jansen makes industry-
• LEED (Leadership in Energy and Environmental Design) specic Environmental Product Declarations in accordance
• Klimaschutz und Energieefzienz Schweiz (Certicate from with ISO 14025 and EN 15804 for windows, doors and façades
the Energy Agency of the Swiss Private Sector) available to the fabricator.
The EPDs can be obtained quickly and easily from the ift test
institute in Rosenheim, Germany.

34 STEEL SYSTEMS VISS FAÇADES















System versatility:


for every application















Windows Façades Fixed glazings Partition walls Conservatories Fire protection Thermal insulation

Systems Doors Safety System speci cations
Janisol/Janisol Primo Doors and windows CE tested, anti- nger-trap door,
Basic depth of doors 60 mm ◆ ◆ ◆ ◆ ◆ ◆ ◆ folding wall, burglar resistance RC3 and bullet
Basic depth of windows 60/64 mm resistance, steel and stainless steel
Janisol HI Doors and windows CE tested, Minergie tested,
Basic depth of doors 80 mm ◆ ◆ ◆ ◆ ◆ ◆ ◆ highly insulated, windows RC3
Basic depth of windows 90 mm
Janisol Arte Windows CE tested, inward and outward opening
Basic depth 60 mm ◆ ◆ ◆ ◆ ◆ windows, very slim face widths
Janisol 2 Doors and xed glazings, re resistant tested EI30,
Basic depth 60 mm/70 mm ◆ ◆ ◆ ◆ ◆ ◆ smoke protection, burglar resistance,
steel and stainless steel
Janisol C4 Doors and xed glazings, re resistant tested EI60
◆ ◆ ◆ ◆ ◆
Basic depth 70 mm and EI90, smoke protection
VISS TV Mullion-transom construction for vertical glazings,
Face width 50/60 mm ◆ ◆ ◆ ◆ ◆ dry glazing, CE tested,
burglar resistance RC4 and bullet resistance

VISS TVS Mullion-transom construction for vertical and roof
Face width 50/60 mm glazings, dry glazing, CE tested,
◆ ◆ ◆ ◆ ◆
burglar resistance RC4 and bullet resistance
VISS Fire Mullion-transom construction for vertical and
Face width 50 mm ◆ ◆ ◆ roof glazings, tested for re resistance to E90/EI90
VISS SG Structural Glazing façade based on the
◆ ◆ ◆ ◆
Face width 50/60 mm tried-and-tested VISS system
VISS Basic / VISS I x tra Construction for steel and stainless steel façades
◆ ◆ ◆ ◆
for mounting on any support
Jansen-Economy 50 Doors and windows CE tested, anti- nger-trap door,
Basic depth of doors 50 mm ◆ ◆ ◆ ◆ ◆ ◆ re resistant tested E30, smoke protection,
Basic depth of windows 50/58,5 mm burglar resistance, steel and stainless steel
Jansen-Economy 60 Doors CE tested, anti- nger-trap door,
Basic depth 60 mm ◆ ◆ ◆ ◆ ◆ re resistant tested E30, smoke protection, burglar
resistance and bullet resistance
Standard pro les Steel pro le series for double action doors,
Basic depth 40, 50, 60, 80 mm ◆ ◆ ◆ ◆ frame doors and pilaster pro les
Folding and sliding doors Steel pro les for folding and sliding doors,
Basic depth 50, 60, 80 mm automatic or manual folding, CE tested

STEEL SYSTEMS VISS FAÇADES 35

598 803 I Steel Systems I 01.2016 I Subject to change

























































Jansen AG




Steel Systems
Industriestrasse 34
9463 Oberriet
Schweiz
jansen.com

Doors & windows





Thermally insulated pro le systems
made from steel and stainless steel

2 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Minimal heat loss


Maximum stability











Doors and windows symbolise openness and provide a way in for people, light and air.
But they also protect from external in uences. The individual requirements for thermal
insulation and sound reduction or burglar and bullet resistance determine how doors
and windows are to be constructed.

The thermally insulated door and window systems of the The range includes the following pro le series:
Janisol series in steel or stainless steel impress with excellent
U values (thermal transmittance) and feature narrow face • Janisol doors (steel and stainless steel): with a basic depth
widths. of just 60 mm, suitable for complex single and double-leaf
doors.
The door and window systems of the Janisol series are • Janisol windows (steel and stainless steel): for generous
suitable for dry and wet glazing, while the door systems window surfaces with slimline frame pro les. Turn/tilt,
are also available with easy-access thresholds. Whether it bottom-hung, horizontal pivot and double-vent windows
be in public buildings, residential construction or renovation are all possible.
projects – the wide Janisol range with its differentiated, • Janisol Primo (steel): highly thermally insulated window
combinable pro le series will meet the most demanding of system with a basic depth of 60 mm.
requirements for thermal insulation. The Janisol systems are • Janisol HI (steel): highly-insulating – the rst Minergie-
also at the forefront in terms of security, mechanical strength certi ed steel window and door system in Switzerland.
and durability. • Janisol Arte (steel): slender thermally insulated windows
with face widths of 25 and 40 mm; ideal for the faithful
renovation of industrial and loft glazing as well as the
windows of listed buildings.







The Janisol systems have successfully passed the tests laid down in the product standard EN 14351-1.
On this basis, manufacturers can label windows and external doors with the CE mark which is obligatory throughout the EU.

STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS 3

4 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Janisol steel systems


Doors and windows











Janisol doors – Proven technology in perfect harmony

The ush-tted prole series is ideally required before welding the frames.
suited for creating visually attractive The range of colours available is
and structurally sophisticated single virtually unlimited; powder coating
and double-leaf doors. The use of high- and wet coating are both possible.
quality insulating bars and mechanically The appearance is coordinated to
undercut rolling means that a high match the other Jansen door systems
degree of rigidity is achieved despite for re and smoke protection. The
a minimal basic depth of 60 mm. sight lines are practically identical.
Structural reinforcements can also be For the developer, this guarantees
easily added. The glass bre reinforced that sight lines are identical even
insulating bars are heat-resistant. As a where requirements are different.
result, no special precautions are





Janisol anti- nger-trap doors –
Safety and design perfectly combined

The rounded half proles minimise or hospitals. The Janisol anti-nger-
the risk of injury at the secondary trap door meets the product standard
closing edge. This then prevents EN 14351-1 for external doors and is
crushing and shearing points as per CE certied.
DIN 18650. With maintenance-free, The anti-nger-trap doors are
high-performance hinge bushes, compatible with the Janisol and
Janisol anti-nger-trap doors are Jansen-Economy 60 range of proles.
particularly suitable for buildings Integrated door closers and automatic
with high frequency use by the side-hung door drives can also
public, e.g. shopping centres, schools be installed.

STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS 5 5 5















Janisol windows – Modern technology with a classical appearance


Torsionally rigid, welded frames allow Our range of products is completed by
large windows with extremely slender a system-compatible and easy-to-install
proles. Arched windows, structural range of ttings (surface-mounted or
reinforcement and aesthetic adaptations concealed). Side-hung, turn/tilt, bottom-
of standard steel proles can also be hung, horizontal pivot and double-vent
produced cost-effectively in individual windows, xed glazing or combinations
units and small quantities. As a result, of these are all possible.
the Janisol system is very much in
demand, not only for newbuilds, but
also for renovation projects.













Janisol Primo – High-quality insulation in the smallest of spaces

This thermally insulated prole Identical prole cross-sections
system with a construction height greatly simplify the fabrication of
of only 60 mm (64 mm vent) enables Janisol Primo, and also allow them
efcient fabrication of xed glazing to be combined with tried-and-tested
and windows (side-hung, turn/tilt, Janisol proles.
double-vent and bottom-hung).
All window vents have a centre gasket As a holistic approach to buildings
and a rebate gasket on the room side. is adopted, energy saving measures
We stock a range of system-tested and thermal insulation are playing an
ttings with single-handed operation ever-greater role. For both economic
and multi-point locking for all possible and ecological reasons, the window
opening types. should be accorded greater importance.

6 A-A STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS




50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50









Example of Janisol doors A-A
A-A
A-A





A-A

B-B 50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50
50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50
50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50


50

50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50
22.5



B-B
B-B
B-B
22.5 50
50 50

22.5 Alternative Alternative
B-B
22.5 22.5
50
50
10 22.5
22.5 22.5 22.5 Alternative Alternative

Alternative
50 50 Alternative Alternative
Alternative
Alternative
50 50 Alternative
10 B
10 10 22.5
22.5 50
50 50 50 Alternative Alternative B
22.5 20 22.5 B B
22.5 22.5 10
20 22.5 A A
22.5 22.5 87.5 50 50 87.5 50 50 20 20 50 22.5 22.5 A B A

22.5 22.5 22.5 87.5 87.5 50 50 50 50 A A A A

50 16.5 22.5
50 16.5 8 22.5 20 22.5
50 50 8 16.5 16.5 22.5 22.5
8 8
8 8 8
8 A A
22.5 87.5 50 50 B
B
B B
50 16.5 22.5
8
8

B

STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOW A-A 7








50 25 22.5 22.5 25 14.5 23 20 22 23 14.5 25 22.5 22.5 25 22.5





Example of Janisol windows

A-A
A-A



A-A



B-B
50 25 22.5 22.5 25 14.5 23 20 22 23 14.5 25 22.5 22.5 25 22.5
50 25 22.5 22.5 25 14.5 23 20 22 23 14.5 25 22.5 22.5 25 22.5

25
50 25 22.5 22.5 25 14.5 23 20 22 23 14.5 25 22.5 22.5 25 22.5
22.5






B-B
B-B Concealed window tting
22.5 35 70
25 105
25
25 22.5 B-B
22.5
14.5 25

23 22.5
22.5 35 70
22.5 105 35 105 70
20 25
25
14.5
22.5 14.5 35 70
23 105 B
23
25
20
20
14.5
22.5 23 B B
20
25 22.5
22.5
22.5 25 25 A B A
22.5 A A
22.5 22.5 A A

25
22.5 A A
20
20
20
35
35
B
35 20 25 B
25
35 22.5 B
22.5
25 B
25
22.5 22.5

8 A-A STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS














A-A
Example of Janisol Primo windows
50 25 14.5 23 20 20 23 17 23 20 20 23 14.5 25 50


A-A

A-A




50 25 14.5 23 20 20 23 17 23 20 20 23 14.5 25 50
B-B



50
50 25 14.5 23 20 20 23 17 23 20 20 23 14.5 25 50
25 50 25 14.5 23 20 20 23 17 23 20 20 23 14.5 25 50
B-B
22.5 50 22.5 25 50
35 47.5 72.5
25
B-B
22.5 Concealed window tting 22.5 25 50
B-B 35 47.5 72.5
50

22.5 25 50
22.5 25 22.5 22.5 25 50
35 47.5 72.5
25
22.5 25 22.5 25 50
35 47.5 72.5
14.5 14.5 22.5 25 22.5 22.5 25 22.5
35 70 35 70
23 105
23 22.5 105
20 B
25 22.5
20 22.5 25 22.5 B
14.5 25
35 70
23 105 22.5 25 22.5
14.5
35 70
20 23 105 B
20 A A
20 B
23
14.5
20 25 A A
20 A A
23 23 20 22.5 A A
B
14.5 14.5 23
25
14.5
25
22.5 25
B
22.5 22.5
B
B

STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS 9

10 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS

STEEL SYSTEMS JANISOL STAINLESS STEEL 11















Janisol stainless steel


Doors and windows











Janisol stainless steel doors Janisol stainless steel windows

The thermally insulated stainless steel Whether you are considering using These slimline, thermally insulated
pro les are based on tried and tested stainless steel for functional or stainless steel pro les complement
Janisol technology. Pro les and sizes aesthetic reasons, Janisol windows the tried-and-tested Janisol range,
are the same as those in the Janisol meet both requirements. adding a variant made from stainless
range. This makes it possible for the A comprehensive range of ttings steel of grade 1.4401 (AISI 316).
designer to combine both types of enables the construction of side-
steel easily and for the fabricator to hung, turn/tilt, double-vent and This material is particularly suitable
use identical accessories and fabrication bottom-hung windows. for use:
tools. The range is complemented by • In industrial areas
a comprehensive range of stainless • In coastal areas (salty air)
steel ttings. The pro le surface is • In areas with strict hygiene
available from stock in a mill nish requirements
or polished. • Near roads (withstands salt and grit)

A-A
12 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS













50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50
Example of Janisol stainless steel doors
A-A
A-A






A-A


50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50
B-B 50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50




50
50 10 50 22.5 22.5 50 10 50 22.5 22.5 50 10 50
22.5 B-B
B-B


50
50
22.5 22.5 22.5 B-B



50
50
22.5 22.5

10 22.5
50
50
50 Alternative
10
10
22.5
Alternative
50 Alternative B
50 Alternative
22.5
50 B B
22.5 22.5
10

50 Alternative
22.5 22.5 22.5
22.5 22.5 22.5 22.5 A A A B A A A

50
50
50 50
50
50
22.5 22.5
22.5 8 8
22.5 22.5 A A
40 B B
8 40
50
50 B
40
22.5
8
B
40

STEEL SYSTEMS JANISOL STAINLESS STEEL A-A 13













50 25 14.5 23 20 A-A 20 23 17 23 20 20 23 14.5 25 50
Example of Janisol stainless steel windows





A-A






50 25 14.5 23 20 20 23 17 23 20 20 23 14.5 25 50




B-B

50 25 14.5 23 20 20 23 17 23 20 20 23 14.5 25 50
50

25
B-B
22.5
50

25
22.5
B-B

50

22.5 25
22.5 22.5
25 B
25 B
14.5 14.5

23
23
20 22.5
20
25 A B A
14.5
A A
23
20
20
A A
23
B
14.5
20 25

22.5 20
23
B
23
14.5 14.5 B

25 25
22.5
22.5

14 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Janisol folding wall


Flexible room design











Steel folding wall – thermally broken

The Janisol folding wall is based on and quiet operation. A range of designs
the Janisol thermally insulated system. is available for the threshold.
Flexible in use, the Janisol folding wall Depending on the size and loading,
system can be used as a room divider proles with a face width of 25 mm
as well as for outside areas, and can or 50 mm can be used. The load-
be inward or outward-opening. bearing capacity of the top running
A compatible range of ttings and gear is up to 200 kg, which in turn
accessories ensures proper, smooth permits leaf weights of up to 100 kg.

A - A
7.5
7.5
10
25
25
25
7.5
10
25
B - B
STEEL SYSTEMS JANISOL FOLDING WALL 7.5 25 10 25 7.5 7.5 25 10 25 15
70

5
25
5
10 Example of Janisol folding wall

25
7.5
A - A










13.5
13.5
25 10 25 7.5 7.5 25 10 25 7.5 7.5 25 10 25 7.5 7.5 25 10 25


B - B
B





70 A A

7.5 5 47.5
25 25 5
10 6.5
10 33 33
25
22.5 8
25 10 7.5 5
1
18 60/20/5
22.5


B
13.5
13.5



B



A A
7.5 47.5
25
6.5
10 33 33
22.5 8
25 10 5
1
18 60/20/5
22.5
B

16 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Pro le range


Janisol doors and windows







1.5 7 1.5 7 1.5 7 1.5 7

46 60 46 60 46 60 46 60

4 4 4 4
3 3
40 10 15 22.5 40 10 15 3 22.5 40 10 15 15 10 15 3
65 87.5 87.5 40
630.013 630.114 630.416 630.010
630.013 Z 630.114 Z 630.416 Z 630.010 Z
630.013.01 630.114.01 630.416.01
630.013.03 630.114.03 630.416.03

3
1.5 7 1.5 7 1.5 4
46 60 46 60 46 54 60


4 4 4
22.5 15 10 15 3 22.5 15 10 15 3 40 10 15 3
62.5 62.5 50
630.110 630.411 600.010 Z
630.110 Z 630.411 Z


1.5 7 1.5 7 1.5 7

46 60 46 60 46 60

3 4 3 4 3 4
75 10 15 22.5 75 10 15 22.5 75 10 15
100 122.5 122.5
630.016 630.115 630.417
630.016 Z 630.115 Z 630.417 Z
630.016.01
630.016.03
3
1.5 1.5 1.5 1.5
57 60 57 60 57 60 54 60


3 3
3 3 22.5 25 22.5
25 22.5 22.5 25 22.5 22.5 25 22.5
47.5 70 70 70
601.635 602.635 603.635 605.635
601.635 Z 602.635 Z 603.635 Z 605.635 Z
601.635.01 602.635.01 603.635.01 605.635.01
601.635.03 602.635.03 603.635.03 605.635.03

STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS 17
















1.5 1.5 1.5

57 60 57 60 57 60


3 3 3
50 22.5 22.5 50 22.5 22.5 50 22.5
72.5 95 95
601.685 602.685 603.685
601.685 Z 602.685 Z 603.685 Z
601.685.01 602.685.01 603.685.01
601.685.03 602.685.03 603.685.03


3 3
1.5 1.5 1.5 1.5

54 60 54 60 60 60


3
50 22.5 3 22.5 50 22.5 50 25
72.5 95
604.685 605.685 600.005 600.006
604.685 Z 605.685 Z 600.005 Z 600.006 Z
604.685.01 605.685.01
604.685.03 605.685.03


3 3
1.5 1.5 1.5 1.5
56 57 60 56 57 60 54 60 54 60

3 3 3 3
50 25 50 25

600.001 600.002 600.007 Z 600.008 Z
600.001 Z 600.002 Z


8.5 9
1.5 11.5 1.5 1.5
10 12.5 12.5 10 1.5 22
61
64 61 64 68.5 57 60
26
3 3 12
3 35
3
20 23 20 20 25 20 25 23 20 4.5 20 25 22.5 3
63 65 68 67.5
630.900 602.636 630.901 Z 601.699.6
630.900 Z 602.636 Z 630.901.01 601.699.6 Z
630.900.01 630.901.03
630.900.03


Z = made from hot-dip 01 = Stainless steel, bright, 03 = Stainless steel polished,
galvanised strip material 1.4401 (AISI 316) grain 220-240
material 1.4401 (AISI 316)

18 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Pro le range


Janisol Primo windows










1.5 1.5 1.5 1.5
57 60 57 60 57 60 57 60



25 22.5 3 50 22.5 3 22.5 25 22.5 3 22.5 25 22.5 3
47.5 72.5 70 70
601.635.6 Z 601.685.6 Z 602.635.6 Z 603.635.6 Z




1.5 1.5 1.5

57 60 57 60 57 60



22.5 50 22.5 3 22.5 50 22.5 3 22.5 50 22.5 3
95 95 95
602.685.6 Z 603.685.6 Z 605.685.6 Z

1.5
1.5 1.5 1.5 1.5

57 60 56 60 57 60 57 60


3
22.5 25 22.5 3 25 1.5 15 22.5 3 22.5 15 22.5
70 37.5 60
605.635.6 Z 600.002.6 Z 601.634.6 Z 602.634.6 Z




Z = made from hot-dip galvanised strip

STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS 19

20 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Janisol HI


For powerful insulation










Highly insulated steel doors reduce thermal transmittance
to a minimum


In busy public buildings in particular, With a basic depth of 80 mm, inll unit
the requirements for security, durability thicknesses of up to 56 mm can be used.
and thermal insulation have increased A comprehensive and coordinated range
dramatically. Janisol HI steel doors of ttings and accessories, as well as a
conveniently combine mechanical range of thresholds, which can be
stability with high thermal insulation selected to suit the situation, provide
properties in one single steel prole the perfect solution for all possible
system. applications. Thanks to the specially
Thanks to insulating bars made from formed insulating bars, the lock can
glass bre-reinforced polyurethane, be installed in the centre of the prole
Janisol HI achieves U values to very easily and efciently.
d
1.0 W/m K.
2





Steel windows with optimum thermal break

Modern windows must meet a number glazing and 0.8 W/m K for windows.
2
of different demands and perform a With a basic depth of 90 mm, vent
variety of functions. They must save heights of up to 2800 mm and a vent
energy, be airtight, watertight and weight of 180 kg are possible. What is
easy to use, meet structural require- more, different inll unit thicknesses
ments, but also be highly attractive. of up to 66 mm can be used. Due to
Janisol HI steel windows and xed the slimline external face width and the
glazing feature insulating bars made wide variety of coating options, Janisol
from glass bre-reinforced polyure- HI steel windows can meet high thermal
thane and boast optimum thermal insulation requirements in terms of both
and structural properties. They achieve function and design.
U values to 0.69 W/m K for xed
2
w

STEEL SYSTEMS JANISOL HI 21

22 A-A STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS




50 20 20 50 10 50 20 20 50 10 50






A-A
A-A
Example of Janisol HI doors









50 50
50 50 20 20 20 20 50 50 10 10 A-A 20 20 20 20 50 50 10 10 50 50
B-B





50



20
50 20 20 50 10 50 20 20 50 10 50
B-B
B-B

50 50


20 20 20



50
B-B
20 20
10
50 50 50
Alternative
50 10 10 20
D
Alternative
Alternative
50 50
D D
20
20 20
20


50
20 20 A A A A
10 20 A A
20 20
Alternative
50 50
50
20 D
50 50
50
20 35 35
20 20 96 96 D D
50
35
20 96 A D A
20
20
50
50
35
96 D
20

STEEL SYSTEMS JANISOL HI 23


A-A










A-A
Example of Janisol HI windows


50 30 20 20 30 20 5 35 35 5 20 30 20 20 30 50





A-A

50 30 20 20 30 20 5 35 35 5 20 30 20 20 30 50








B-B
50 30 20 20 30 20 5 35 35 5 20 30 20 20 30 50


30 B-B

20
30

20


B-B



30
20
20
20
B
30 B
30
15
15
25 25
20
20
20
B
30
A A
15
A A
25
25 20
25
25
15
B
25
30 A A
15
20 B
30 25

25
20
15
B
30
20

24 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Pro le range


Janisol HI











Doors


40 10 40 10 60 10
3
1.5 10 1.5 10 10 1.5


60 80 60 80 60 80 74 80


1.5
7 7 7
50 15 3 20 50 15 3 20 50 15 3 20 50 20 3
65 85 85 90
680.013 Z 680.114 Z 680.416 Z 680.650 Z




20 10 20 10 40 10 12 28 10
3
1.5 10 1.5 10 10


60 80 60 80 60 80 74 80

1.5
7 7 7
30 15 3 20 30 15 3 20 30 15 3 10 28 12 3
45 65 65 50
680.010 Z 680.110 Z 680.411 Z 680.050 Z





Z = made from hot-dip galvanised strip

STEEL SYSTEMS JANISOL HI 25
















Fixed glazings

1.5 1.5 1.5 1.5


77 80 77 80 77 80 77 80




30 20 3 50 20 3 20 30 20 3 20 50 20 3
50 70 70 90
681.630 Z 681.650 Z 682.630 Z 682.650 Z




1.5 1.5
1.5 1.5

77 80 77 80 77 80 77 80




20 30 20 3 20 50 20 3 20 30 20 3 20 50 20 3
70 90 70 90
683.630 Z 683.650 Z 685.630 Z 685.650 Z





Windows


1.5 12.5 9.6 10 1.5
1.5
12.5 12.4

90 87 90 87 90
60.5

3
20 15 10 20 4.5 20 30 20 3 20 30 20 3
65 70
70
680.900 Z 680.901 Z 680.902 Z

26 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Janisol Arte 2.0


The new generation











Simpli ed fabrication; new materials for pro les

The second generation of the Janisol Arte window system Design bene ts
now offers pro les made from stainless steel and Corten • Inward and outward-opening xed glazing/window vents
steel as well as a wide range of pro les. The integrated • Single and double-vent windows
weatherstrip groove simpli es and speeds up fabrication. • Inward-opening side-hung, bottom-hung and double-vent windows
A large selection of glazing beads is also available in a • Outward-opening side-hung, top-hung, double-vent,
variety of different materials. horizontal pivot and projected top-hung windows
The wide range of opening types is ideally suited for the • Vent sizes of 1000 × 2400 mm
renovation of old windows but also for modern residential • Vent weight of up to 150 kg
construction. With the narrowest pro le face widths of only • Unit thicknesses from 20 to 47 mm
25 or 40 mm for xed glazing and a basic depth of 60 mm, • U value from 0.8 W/m K
2
w
intricate yet stable constructions with a large proportion of • Multi-point window locking
glass and excellent thermal insulation can be created. • New materials for pro les: stainless steel and Corten
Fabrication bene ts
• Composite technology tested in accordance with EN 14024
• CE classi cation in accordance with EN 14351-1
• Optimum weldability of the pro le frame due to the
ZF surface nish
• Mechanical strength tested in accordance with EN 13115
• Impact resistance tested in accordance with EN 13049




























Janisol Arte 2.0 Janisol Arte 2.0 stainless steel Janisol Arte 2.0 Corten

STEEL SYSTEMS JANISOL ARTE 27
































Janisol Arte
horizontal pivot window

The new Janisol Arte horizontal pivot window
has been successfully CE marked. Vents of up
to 1400 × 1600 mm can be constructed as manual
or motorised versions.

• Vent weights of up to 100 kg
• Watertightness 8A - 450 Pa
• Air permeability up to class 4
• Sound reduction up to 40 dB











Janisol Arte
sliding doors

With the extremely slimline steel pro le system Janisol Arte,
large sliding doors can be created with narrow face widths
and a high degree of stability. Originally developed by Jansen
for the reconstruction of historic windows, Janisol Arte now
offers architects and developers the opportunity to create
large glass fronts.

• Unit sizes of up to 3000 × 2500 mm (W×H)
• Max. weight of 150 kg per leaf
• Insulating glass of 20 to 34 mm
• U value of 1.5 W/m K
2
w
• Welded steel half pro les in combination with glass bre-
reinforced high-performance plastics (100% recyclable)
produce particularly stable frames
• Pro le face widths of just 40 mm ensure increased light penetration
and also increase the energy ef ciency of the building
• CE marking in accordance with EN 14351-1
• Pro le rolling technology tested in accordance with EN 14024
• Sound reduction of up to 41 dB

28 STEEL SYSTEMS THERMALLY INSULATED DOORS & WINDOWS















Janisol Arte 2.0 pro le range


3

57 60 57 60 57 60 54 60

3 3 3 3
10 15 15 10 15 15 10 15 15 10 15
25 40 40 40
601.611 Z 602.611 Z 603.611 Z 605.611 Z
601.611.01 602.611.01 603.611.01 605.611.01
601.611.09 602.611.09 603.611.09 605.611.09




3

63 66 63 66 54 60
60

3 3 3
15 10 15 15 10 15 10 15
40 40 25 10
602.612 Z 603.612 Z 600.609 Z 600.610 Z
602.612.01 603.612.01
602.612.09 603.612.09



3
57 60 57 60 57 60 54 60


3 3 3 3
25 15 15 25 15 15 25 15 15 25 15
40 55 55 55
601.615 Z 602.615 Z 603.615 Z 605.615 Z
602.615.01


3

57 60 57 60 57 60 54 60


3 3 3 3
10 15 15 10 15 15 10 15 15 10 15
25 40 40 40
601.610 602.610 603.610 605.610
601.610 Z 602.610 Z 603.610 Z 605.610 Z
601.610.01 602.610.01 603.610.01 605.610.01
601.610.09 602.610.09 603.610.09 605.610.09




Part no.
without addition = bright with 01 = Stainless steel, bright, material 1.4401 (AISI 316)
with Z = hot-dip galvanised steel with 09 = Steel KB DOCOL 355W (Corten)


Click to View FlipBook Version