Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Fire Rated Ceilings - Plasterboard Installation
Rondo PN 128 Top Cross Rail Rondo PN 121 Suspension Rods End joints formed on Furring
@ 1200mm max ctrs @ 1200mm max ctrs Channels and staggered,
otherwise end joints on first layer
Rondo PN 2534 Suspension Clip 1200mm max must be back-blocked.
Where applicable, end joints of
Rondo PN 139 1200mm max second and third layers should be
Joiner Clip screw laminated to previous layer
@ 200mm max ctrs
200mm
150mm
Plasterboard fasteners to be 200mm 1, 2 or 3 layers of Boral Rondo PN 129 Furring Channel
max ctrs in field and 150mm max Plasterboard Firestop® fixed @ 600mm max ctrs
ctrs on end joints - staggered transverse to Furring Channels
@ 600mm max ctrs. All joints Tape and finish face layer only
Screw Fixing Layout staggered min 200mm with selected Boral Plasterboard
system
Screws 10mm to 16mm
from edges
D3 Ceilings
BORAL PLASTERBOARD | February 2009 D3. 3
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
Fire Rated Ceilings - Back-blocking
Back-blocking is a mandatory fixing requirement where specified
in the Australian Standard AS/NZS 2589.1:1997.
Failure to provide back-blocking installed as per
AS/NZS 2589.1:1997 may result in liability for any associated
costs relating to maintenance and/or rectification caused by
jointing defects.
Laminate back-block to back face Ceiling framing
of ceiling with 10 x 38 Type L
screws @ 200mm ctrs 200mm min
Apply cornice adhesive or back- 200mm min Firestop® same thickness as
blocking adhesive over full face of 100mm min ceiling board
back-blocking piece with a
notched spreader to form beads Joints in other layers staggered
6mm x 6mm @ approx 20mm ctrs min 200mm from previous layer
and at right angle to joint
Laminate back-block to back face
Single Layer Back-block Detail of ceiling with 10 x 38 Type L
screws @ 200mm max ctrs
EQ
EQ
Form plasterboard dry back-block
behind all end joints not formed
on framed members
Multi Layer Back-block Detail
D3 Ceilings
D3.4 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Fire Rated Ceilings - Perimeter Rondo PN 121 Suspension Rod
@ 1200mm max ctrs
Rondo PN 2534 Suspension Clip
Continuous Rondo PN 553 Angle 100mm max Rondo PN 128 Top Cross Rail
or Steel Stud fastened to wall 6 - 10mm
@ 600mm max ctrs Rondo PN 139 Joiner
Approved Sealant 100mm max Rondo PN 129 Furring Channel
6 - 10mm 1 x 16mm
Cornice Adhesive Boral Plasterboard Firestop®
Plasterboard Cornice or Alternative Detail
taped square set finish
Typical Perimeter Detail - FRL 30/30/30
6 - 10mm Rondo PN 554 Angle
Rondo PN DU05 Wall Trim 10mm 22mm Promaseal IBS
2 or 3 layers of Boral Plasterboard by Promat Fyreguard
Firestop® as required
Rondo PN P50 Shadowline Trim
Wall Trim Detail Shadowline Trim Detail
100mm max 2 or 3 layers of Boral Plasterboard
Firestop® as required
6 - 10mm 3 - 10mm
16mm max Plasterboard Cornice
Framing
25 x 25mm fillet 25 x 25mm fillet
of Cornice Adhesive of Cornice Adhesive
Plasterboard Cornice Top Plate 10mm Boral Plasterboard
45mm thick Standard Core
5mm max o/hang Cornice Adhesive
Plasterboard Cornice Detail
Alternative Plasterboard Cornice Detail
Typical Perimeter Detail - FRL 60/60/60 D3 Ceilings
BORAL PLASTERBOARD | February 2009 D3. 5
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
» Fire Rated Ceilings - Perimeter Roofing or flooring
Framing member
Rondo PN 274
Suspension Bracket Rondo PN 2534 Suspension Clip
Rondo PN 128 Top Cross Rail
Rondo PN 121 Suspension Rod 600mm max Rondo PN 139 Joiner
@ 1200mm max ctrs 6 - 10mm Rondo PN 129 Furring Channel
3 x 16mm Boral Plasterboard
Continuous Rondo PN 553 Angle Firestop®
or Steel Stud fastened to wall
@ 600mm max ctrs
Approved fire rated sealant
Optional Plasterboard Cornice
or taped square set finish
600mm max
6 - 10mm
Cornice Adhesive Rondo PN 129 Furring Channel
Optional Plasterboard Cornice or
taped square set finish 3 x 16mm Boral Plasterboard
Firestop®
Typical Perimeter Detail - FRL 90/90/90
Alternative Detail
D3 Ceilings
D3.6 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
» Fire Rated Ceilings - Perimeter
100mm max
6 - 10mm
Framing
2x16mm Boral Firestop® Cornice Adhesive
or Wet Area Firestop™
129 Furring Channel @ 600mm ctrs
Plasterboard cornice or on 237 clips @ 1200mm ctrs
taped square set finish fastened to framing with 12 x 50
roofing screw.
100mm max Or 581 Resilient Channel
6 - 10mm @ 600mm ctrs fastened to framing
Continuous 553 angle.
Fasten to wall @ 600mm ctrs max
Approved Fire Sealant
Alternative Detail
Typical Perimeter Detail - FRL 120/120/120
D3 Ceilings
BORAL PLASTERBOARD | February 2009 D3. 7
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
Fire Rated Ceilings - Bulkhead Roofing or flooring
Rondo PN 2534 Suspension Clip
Framing Member Rondo PN 139 Joiner pop rivetted
to Top Cross Rail
Rondo PN 274 Rondo PN 128 Top Cross Rail
Suspension Bracket Rondo PN 129 Furring Channel
Rondo PN 121 50mm x 50mm x 0.75mm
Suspension Rod Galvanised Steel Angle
Additional Rondo PN 121
Suspension Rod Corner Bead if Required
Rondo PN 2534
Suspension Clip
25 x 25 x 0.75mm BMT
Galvanised Angle pop rivetted
to Top Cross Rail
Rondo PN 128
Top Cross Rail
50mm x 50mm x 0.75mm
Galvanised Steel Angle
1, 2 or 3 layers of Boral
Plasterboard Firestop®
as required
Rondo PN 129 Furring Channel
Typical Bulkhead Detail
D3 Ceilings
600mm max drop
D3.8 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Fire Rated Ceilings - Movement/Control Joints
Type L screws @ 200mm ctrs Framing
Approved fire grade sealant
1, 2 or 3 layers of Boral
Plasterboard Firestop®
as required
10 -12mm
Typical Control Joint Detail
Notes:
1. Locate joint centrally between framing members when parallel to framing.
2. Minimum of one layer of Boral Firestop® Plasterboard continuous over joint.
3. Ensure single layer system is back blocked.
FRL 30/30/30: 120mm 20mm Roofing or flooring
1 x 16mm Boral Plasterboard 50mm
FireSTOP™. D3 CeilingsFraming member
FRL 60/60/60 and FRL 90/90/90: 100mm max 20mm max Rondo PN 121 Suspension Rod
2 x 16mm Boral Plasterboard @ 1200mm max centres
FireSTOP™ Rondo PN 2534 Suspension Clip
Rondo PN 128 or 127
Rondo PN 274 Suspension Bracket Top Cross Rail
Minimum 6 x 50 Type L screws to Rondo PN 129
one side only @ 200mm max ctrs Furring Channel
Rondo PN 139 Joiner
1, 2 or 3 layers of
Boral Firestop®
Plasterboard as required
Rondo PN P35
Expansion Joint Bead if required
Typical Movement Joint Detail
BORAL PLASTERBOARD | February 2009 D3. 9
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
Fire Rated Ceilings - Lights 450mm Rondo PN 274 Suspension Bracket
100mm
Flooring or roof Prefabricated metal light stirrup
Light fitting box
Framing member
Rondo PN 128 Top Cross Rail
Rondo PN 121 Support mounting
Suspension Rod spaced to
support any additional mass
due to light fitting
Rondo PN 2534
Suspension Clip
Rondo PN 129
Furring Channel
1, 2 or 3 layers of Boral
Plasterboard Firestop®
as required
Typical Light Recess Detail
D3 Ceilings
D3.10 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Fire Rated Ceilings - Electrical and Loaded Penetrations
Rondo PN 121 Suspension Rod
Rondo PN 2534 Suspension Clip Cable
Fyre Spring by Promat Fyreguard.
Rondo PN 128 Top Cross Rail Refer to Promat Fyreguard Pty Ltd
Rondo PN 139 Joiner for details
1, 2 or 3 layers of Boral Rondo PN 129 Furring Channel
Plasterboard Firestop®
as required Promaseal Fire Mastic
by Promat Fyreguard
Cable Penetration Detail
Two 100 x 100mm pieces of
Rondo PN 121 Suspension Rod 16mm Boral Firestop® with
lower piece slotted for cable
Rondo PN 2534 Suspension Clip Cable
Cable set in Boral Cornice
Rondo PN 128 Top Cross Rail Adhesive or approved
Rondo PN 129 Furring Channel fire rated sealant
Rondo PN 139 Joiner
1, 2 or 3 layers of Boral Steel Suspension Rod and bracket
Plasterboard Firestop® to engineer’s details
as required
Alternative Cable Penetration Detail
Framing member
Rondo PN 274 Suspension Bracket
Rondo PN 121 Suspension Rod
Rondo PN 2534 Suspension Clip Rod set in Boral Cornice Adhesive D3 Ceilings
Rondo PN 128 Top Cross Rail or approved fire rated sealant
Rondo PN 139 Joiner Rondo PN 129 Furring Channel
1, 2 or 3 Layers of Boral 6-10mm gap
Plasterboard Firestop®
as required
Typical Loaded Penetration Detail
BORAL PLASTERBOARD | February 2009 D3. 11
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
» Fire Rated Ceilings - Plumbing Penetrations
100mm max dia Copper Pipe Cage by Promat Fyreguard (refer
to Promat Fyreguard tests)
50 x 20mm Promaseal IBS by
Promat Fyreguard 13mm max
D3 Ceilings
520mmRondo PN 128 Top Cross RailAA Promaseal Fire Mastic
by Promat Fyreguard
Rondo PN 139 Joiner
Rondo PN 129
Furring Channel
1 or 2 layers of Boral Plasterboard
Firestop® as required
15mm min
100mm max dia Copper Pipe
Line of 50 x 20mm Promaseal IBS
by Promat Fyreguard
View AA uPVC Pipe independently
supported above ceiling
Typical Copper Pipe Penetration - FRL 30/30/30 and FRL 60/60/60
Rondo PN 129 Furring Channel
Steel toggle bolt Retrofit Fyre Collar by Promat
Rondo PN 128 Top Cross Rail Fyreguard. Refer to Promat
Rondo PN 139 Joiner Fyreguard Pty Ltd for details
1, 2 or 3 layers of Boral
Plasterboard Firestop® Water pipe independently
as required supported above ceiling
Typical uPVC Pipe Penetration Rondo PN 129 Furring Channel
Approved fire grade sealant
Rondo PN 128 Top Cross Rail
February 2009 | BORAL PLASTERBOARD
Rondo PN 139 Joiner
1, 2 or 3 layers of Boral
Plasterboard Firestop®
as required
Sprinkler head
Typical Sprinkler Pipe Penetration
D3.12
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Fire Rated Ceilings - Beam Protection 50 x 50 x 0.75mm or
75 x 75 x 0.75mm
Roofing or continuous galv steel angles
Flooring as required
Framing member Furring Channel stirrups
@ 600mm ctrs
Rondo PN 226 or 1, 2 or 3 layers of Boral
394 Direct Plasterboard Firestop®
Fixing Clip as required
Rondo PN 129
Furring Channel 1, 2 or 3 layers of Boral
Plasterboard Firestop®
Steel Beam as required
Type W screws as required
1, 2 or 3 layers of Boral @ 200mm ctrs
Plasterboard Firestop®
as required D3. 13
50 x 50 x 0.75mm continuous
Galv Steel Angles
Corner Bead if required
Typical Steel Beam Protection Detail
Note:
Vertical plasterboard fixed as per ceiling
Roofing or
Flooring
Framing member
Rondo PN 226 or
394 Direct
Fixing Clip
Rondo PN 129
Furring Channel
50 x 50 x 0.75mm or
75 x 75 x 0.75mm
continuous galv steel angles
as required
Timber Beam
Corner Bead if required 50mm min D3 Ceilings
Typical Timber Beam Protection Detail
BORAL PLASTERBOARD | February 2009
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
This page left blank intentionally.
D3 Ceilings
D3.14 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Non Fire Rated Ceilings - Plasterboard Installation
4 daubs of adhesive Daubs of adhesive 200mm from
25mm dia x 15mm high for sheets edge of sheets
1200mm and 1350mm wide
Centre line of sheet
CL 200mm
200mm
CL
CL
Space daubs of adhesive
@ 230mm max ctrs
Adhesive and Mechanical Fixing Layout (conventional spacing shown)
Adhesive / Fastener Layout
Ceilings
Plasterboard Width (mm) Conventional 1/3 Spacing
Spacing FAFAF
FAFAFAF
900 FAFAF FAFAFAF
1200 FAAF/FAAF
1350 FAAF/FAAF
F = Screw F/F = Double Screw A = Adhesive
Notes:
• Under slow-drying conditions, keep Boral Plasterboard sheets firm against the
adhesive daubs for at least 48 hours. Use temporary blocks fastened through
plasterboard to framing members.
• Be sure to fix Boral Plasterboard within thirty minutes of applying adhesive.
This will avoid skin forming on the adhesive.
D3 Ceilings
BORAL PLASTERBOARD | February 2009 D3. 15
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
» Non Fire Rated Ceilings - Plasterboard Installation
Back-blocks laminated to face Note: Rondo Suspension Rods
sheet with cornice adhesive on all All joints not formed on a Furring to manufacturer’s details
longitudinal joints and on butt or Channel must be back-blocked
end joints Rondo Furring channel
Rondo Joiner to manufacturer’s details
Rondo Suspension Clip to manufacturer’s details @ 600mm max ctrs (450mm max
to manufacturer’s details ctrs for 10mm Standard Core
Plasterboard)
Rondo Top Cross Rail
to manufacturer’s details
200mm
300mm
Tape and finish with preferred Screws 10mm to 16mm Screw fastening is illustrated
Boral Plasterboard joining system from edges using min 6 x 25 Type S or Type D
screws. Screws to be max 300mm
1 layer of 10mm or 13mm Boral ctrs in field and 200mm max ctrs
Plasterboard Standard Core or on end joints (staggered)
10mm Boral Plasterboard
Unispan® fixed transverse to -
Furring Channels
Screw Fixing Layout
Screw Fixing Layout
Minimum Fixing Points per Sheet Width
Plasterboard Width (mm) Single Screws
900 4
1200 5
1350 6
D3 Ceilings Notes:
When screw-fixing single layers of Boral Plasterboard sheets:
• Hold plasterboard sheets firmly in place against the framing members while
driving in the screws.
• Adjust screw gun correctly so as to drive the screw heads below the surface
of the sheet without puncturing the face linerboard.
• Press tip of screw firmly into the face linerboard before driving it home.
• Always drive screws with the shank at right angles to the face of the sheets.
• Wherever possible always start from the centre of the sheet toward the
outer edges.
• Position screws on adjacent edges opposite each other.
D3.16 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Non Fire Rated Ceilings - Back-blocking
Back-blocking Back-blocking Butt Joints
Back-blocking is a mandatory fixing requirement where specified Back-block butt joints as follows:
in the Australian Standard AS/NZS 2589.1:1997.
• Fix ceiling sheets with ends butted neatly together. The butt
Failure to provide back-blocking installed as per AS/NZS joint should fall within 50mm of the mid-span point between
2589.1:1997 may result in liability for any associated costs framing members.
relating to maintenance and/or rectification caused by
jointing defects. • Use battens and packers to support and deflect the sheet
ends upwards about 2mm.
Back-blocking substantially reduces call-backs, in particular for
cracking and peaking joints. Back-block Rafter or joist
Recessed Joints in Ceilings Temporary nailing Packing strip Cornice adhesive
Plasterboard Temporary battens
Any area containing three or more recessed joints must be back-
blocked as follows: Typical Back-blocking of Butt Joint
{ Fix Boral Plasterboard ceiling sheets transverse to framing Back-blocking Dos and Don’ts
members.
• Back-blocking must be installed at the fixing stage.
| Place back-block pieces 200mm wide along the full length • Joints must not be set prior to back-blocking.
of fixed sheets edge with cornice adhesive (or back-blocking • Do not use plaster in its advanced setting state or any dry
adhesive). Cornice adhesive to be applied to full face of back-
blocks using notched spreader to form beads of 6mm x 6mm mix compound for back-blocking. Dry or partly dry compounds
at approx 20mm centres and at right angles to joint. combined with ceiling temperatures may cause premature
dry-out and reduced bond.
} Fix the next sheet immediately after back-blocks are in place. • Ensure back-blocking is completely dry prior to the taping process.
• Do not use Stud Adhesive for back-blocking.
Ceiling framing beyond • Back-blocking strips should not be tight between framing members.
Plasterboard 200mm
Back-block pieces
y
zx
Recessed joint
Cornice adhesive
Typical Back-blocking of Recessed Joint
D3 Ceilings
BORAL PLASTERBOARD | February 2009 D3. 17
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
Non Fire Rated Ceilings - Perimeter
Rondo PN 129 Furring Channel Rondo PN 127 Top Cross Rail
Wall angle trim Rondo PN 139 Joiner
Typical Bulkhead Detail - Section Through Top Cross Rail 1 layer of 10mm or 13mm Boral
Plasterboard Standard Core or
10mm Boral Plasterboard
Unispan® as required
Rondo PN 129 Furring Channel Rondo PN 127 Top Cross Rail
Boral Plasterboard cornice
Rondo PN 139 Joiner
Typical Bulkhead Detail - Section Through Furring Channel
1 layer of 10mm or 13mm Boral
Plasterboard Standard Core or
10mm Boral Plasterboard
Unispan® as required
D3 Ceilings
D3.18 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
Non Fire Rated Ceilings - Bulkhead Rondo PN 121 Suspension Rod
Rondo PN 2534 Suspension Clip
Rondo PN 139 Joiner Rondo PN 127 Top Cross Rail
Pop rivet
Continuous galvanised steel angle Rondo PN 129 Furring Channel
Pop rivet
Corner bead if required 1 layer of 10mm or 13mm Boral
Plasterboard Standard Core or
Typical Bulkhead Detail - Section Through Top Cross Rail 10mm Boral Plasterboard
Unispan® as required
Rondo PN121 Suspension Rod
Rondo PN 127 Top Cross Rail Rondo PN 139 Joiner pop rivettedD3 Ceilings
Rondo PN 129 Furring Channel to Top Cross Rail
Corner bead if required Rondo PN 2534 Suspension Clip
Typical Bulkhead Detail - Section Through Furring Channel Galvanised Angle pop rivetted to
BORAL PLASTERBOARD | February 2009 Top Cross Rail
1 layer of 10mm or 13mm Boral
Plasterboard Standard Core or
10mm Boral Plasterboard
Unispan® as required
D3. 19
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
Non Fire Rated Ceilings - Acoustic Details Daubs of Stud Adhesive at
230mm max ctrs for two layer
Refer page D3.21 for plasterboard application, across
Acoustic Mount fixing details width of sheet, 200mm from
edges of sheets and screw points,
at Furring Channel locations
300mm min overlap
Screw along centerline of sheet
Second layer of Boral
Plasterboard Soundstop®
Resilient Channel fixed to timber Alternative Detail
joist at each crossing with
6g x 32mm type W screws
Plasterboard Fixing Layout - Acoustic Ceiling Mount and Resilient Channel
Notes:
• For fire rated ceilings refer page D3.3 for Firestop® Plasterboard details.
• Single layer application of Boral Plasterboard Soundstop® screw-fastened to Furring Channels/Resilient Channels
as per standard installation details (refer page D3.16).
• First of two layer application, Boral Plasterboard Soundstop® screw-fixed to Furring Channel across sheet width at 300mm maximum centres.
D3 Ceilings
D3.20 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
» Non Fire Rated Ceilings - Acoustic Details
Boral Acoustic Ceiling Mount Suspended Application
Direct Fix Application Mount Assembly
Assemble the mount as shown in the following illustration.
Screws (supplied by others) 1. Clip the Interchange Clip into the Top Cross Rail.
2. Clip Furring Channel into the Furring Channel Clip.
• 14 - 10 x minimum 65mm Type 17 roof screw into timber
• 12 or 14 gauge x minimum 45mm drill point roofing screw into Rondo
Top Cross Rail
light gauge steel
• “Tapcon” screw into concrete.
Mount Assembly
Assemble the mount as shown in the following illustration.
1. Screw fix the mount via the central hole in the rubber Furring Channel Clip
element. For fire rated ceilings, a 25mm diameter x 2mm steel
washer is required under the fastener head. Rubber element showing
colour coding dot
2. Use a suitable power tool with an appropriate hex driver and Interchange Clip
tighten the fastener to a point where there is no compression
of the rubber element. Check the pull-out capacity of the
fastener to ensure correct size is selected.
3. Clip furring channel into the Furring Channel Clip.
Ceiling 28mm Furring Channel
support structure
Rondo Sound Isolation Mount STWC
Furring Channel Clip Direct Fix Application
Rubber element showing Screw 6g x 60mm Type W Screw into timber
colour coding dot • 6g x 45mm Type S screws for steel BMT up to 0.8mm
• 6g x 45mm Type D screws for steel BMT 0.8mm - 2mm
Fixing screw (with 25mm dia • “Tapcon” screw into concrete.
steel washer where fire rating
required) Nominal 53mm
28mm Furring Channel (including 5mm
static deflection)
Nominal 68mm
(including 5mm static deflection)
D3 Ceilings
BORAL PLASTERBOARD | February 2009 D3. 21
D | Installation Details Selector+ PLASTERBOARD SYSTEMS
» Non Fire Rated Ceilings - Acoustic Details
Maximum Spacing of Resilient Channel
Plasterboard Joist Spacing 600mm
Thickness 450mm
600
Single Layer Application 600
600
10mm1 600
600
13mm 600 600
400
16mm 600
Double Layer Application
10mm1 600
13mm 600
16mm 600
Note:
1. Resilient Channel spacing 450mm centres for 10mm Standard Core plasterboard.
Maximum Spacing of Boral Acoustic Ceiling Mount/Rondo Sound Isolation Mount STWC
Plasterboard Joist Spacing Maximum Spacing of Joist Spacing Maximum Spacing of
Thickness 450mm 28mm Furring Channel 600mm 28mm Furring Channel
Single Layer Application 1350 (B, R) 450 1200 (B, R) 450
10mm1, 3 1350 (B, R) 600 1200 (B, R) 600
10mm2 1350 (B, R) 600 1200 (B, R) 600
13mm1, 3, 4 1350 (B, R) 600 1200 (B, R) 600
16mm4
1350 (B, R) 450 1200 (B, R) 450
Double Layer Application 1350 (B, R) 600 1200 (B, R) 600
10mm1, 3 1350 (B, R) 600 1200 (B, R) 600
10mm2 1350 (W) 600 1200 (W) 600
13mm1 1350 (W) 600 1200 (W) 600
13mm3, 4
16mm4 900 (W) 600 1200 (W) 450
Three Layer Application 900 (W) 450 600 (W) 600
16mm4
Four Layer Application
16mm4
D3 Ceilings Notes: (B). Boral Acoustic Ceiling Mount - ‘Blue’ dot rubber element
(maximum load 17kg per mount with 5mm static deflection)
1. Boral Plasterboard Standard Core
2. Boral Plasterboard Unispan® (W). Boral Acoustic Ceiling Mount - ‘White’ dot rubber element
3. Boral Plasterboard Soundstop® (maximum load 25kg per mount with 5mm static deflection)
4. Boral Plasterboard Firestop®,
(R). Rondo Sound Isolation Mount STWC (maximum load 16kg per mount).
for fire rated ceilings refer page D3.2 for details
D3.22 February 2009 | BORAL PLASTERBOARD
Selector+ PLASTERBOARD SYSTEMS D | Installation Details
D4 | Reference
Old/New Reference Guide
Old Ref New Ref Old Ref New Ref Old Ref New Ref Old Ref New Ref Old Ref New Ref
ACWS1 ST1010 ASTS15 TS1616F CPS10 PSC32F CS22 C48F SS9 S1313
ACWS10 ST3232F ASTS16 TS1313F CPS10 PSC38F SS1313F
ACWS2 ST1313 ASTS17 TS1313F10 CPS12 PSC13F CS22 CF48F SSS1 SS2626F
ACWS2 ST1313F ASTS18 TS2626F CPS12 PSC25F SS3232F
ACWS3 ST1616F ASTS20 TS3232F CPS12 PSC32F CS22 CS48F SSS3 TS1616F
ACWS4 ST1326F ASW1 SH16F CPS12 PSC38F TS2626F
ACWS6 ST2626F ASW2 SH32F CPS14 PSC13F CS4 CHS48F SSS4 TS3232F
ACWS7 ST3232F ASW3 SH1616F CPS14 PSC25F SH32F
ACWS8 ST4848F ATS1 T10 CPS14 PSC32F CS5 CSP3248F STS5 SH1616F
ACWS9 ST3232F ATS15 T2626F CPS14 PSC38F SH16F
ADM10 M20.01 ATS16 T3232F CPS20 PSC25F10 CS6 C64F STS6 SH29F
ADM10 M20.01CF ATS2 T13 CPS20 PSC50F SH26F
ADM20 M90B ATS2 T16F CPS20 PSC75F CS6 CF64F STS7 WP20
ADM21 M110B ATS20 TR1616F10 CPS40 PSC1313F WP13A
ADM22 M110B ATS22 TR2626F CPS40 PSC2626F CS6 CS64F SW2 WP10
ADM23 M150B ATS23 TR3232F CPS40 PSC3232F WP13
ADM24. M110B ATS24 25TP1010 CPS40 PSC3939F DM3 MF1616F SW3 WP10A
ADM25 M150B ATS25 TT2626F CPT10 PTC26F WPB1313
ADM26 M90B ATS26 50TP1010 CPT20 PTC26F DM3 MF16F SW4 WPB2626
ADM27 M90B ATS27 TT1616F CPT20 PTC13F WPL20
ADM28 M90B ATS28 TT1616F CPT20 PTC39F DM3 MF2626F SW5 WP2010U
ADM4 M150C ATS29 TT3232F CPT20 PTC48F SWP1020
ADM8 M10.01 ATS30 TT2929F CS1 PCS25F DM3 MF26F SW6 WP13A
ADM9 M15.01 ATS4 T1010 CS10 C48F TWP1020
ADP3 VS57F ATS5 T1313 CS10 CF48F DM3 MF3232F SWP1 WP13A
ADP4 VS48F ATS5 T1313F CS11 CSP3232F T3232F
ADP5 VS48F+S10 ATS6 T1616F CS15 C32F DM3 MF32F SWP10 TBV16F
ADP5 VS48F+T10 ATS9 TR1616F CS15 CF32F TBV10
ADSS1 D1616F BPS10 PSB38F CS15 CR32F DSS1 D1616F SWP2(1) T2626F
ADSS3 D2626F BPS11 PSBT48F CS15 CS32F T3232F
ADSS5 D3232F BPS12 PSBC48F CS16 CHS32F DSS3 D2626F SWP2(2) T3232F
ADSS6 D6464F BPS30 PSB50F CS17 C16F T2626F
ARR1 COCT10U BPS40 PSB3232F CS17 CF16F DSS5 D3232F SWP2(3) TBV26F
ARR3 C13 BPT20 PTB13F CS17 CR16F TT2626F
ARR3 COC13 BPT20 PTB26F CS17 CS16F DSS6 D6464F SWP4 50TP1010
ARR4 C16F BPT20 PTB39F CS18 C10 T2626F
ARR4 C16F BPT20 PTB48F CS18 C10U EW1 FC32F SWP5 TT1616F
ARR4 COC16F CinemaZone CS18 C13 TT1616F
ARR4 COD16F Bronze TR26A10 CS18 CF10U EW2 FC39F SWP6 TT3232F
ARR5 C32F CinemaZone CS18 CF13 TT2929F
ARR5 COC32F Gold ST2626A CS18 CS10U EW2 FC48F SWP7 OW16WF10
ARR5 COD32F CinemaZone CS18 CS13 OW32WF10
ASS1 S1010 Gold TF39(26)A10 CS19 C13F EW13 50IW13 SWP8 25TP1010
ASS2 S1313 CinemaZone CS19 C16F 25TP1313A
ASS3 S1616F Gold TT2626A CS20 C26F EW13F 50IW13F SWP8 T1616F
ASS5 S1326F CinemaZone CS20 CF26F T1616F
ASS7 S2020 Silver TF26(13)A10 CS20 CR26F EW13S13 50IW13S13 SWP9 TBV16F
ASS8 S2626F CPC10 CS20 CS26F T32F
ASS9 S3232F CPC10 PCC13F CS21 C29F EWS13FS13F 50IWS13FS13F SWP9 T1616F
ASSS3 SS2626F CPC20 PCC25F CS21 CF29F T1616F
ASSS4 SS1616F CPC20 PCC13F CS21 CR29F EWS13AS13A 50IWS13AS13A TS1 T2626F
ASSS6 SS3232F CPS10 PCC25F CS21 CS29F
PSC13F EWF13FS13F 50IWF13FS13F TS10
O/wall 60 OW16WF10 TS11
O/wall 90 OW32WF10 TS12
O/wall 90A OW32WF16F TS13
O/wall 90B OW26WF10 TS14
O/wall 90C OW16WF26F TS15
O/wall 90D OW16WF16F TS16
O/wall 90E OW26WF10 TS18
O/wall 90F OW16WF26F TS19
PWS1 25SP1010 TS2
PWS3 25SP1313A TS20
PWT1 25TP1010 TS21
PWT2 25TP1313A TS22
PWT4 50TP1010 TS23
PWT6 50TP1313A TS24
SR3 VS57F TS25 D4 Reference
SR4 VS48F TS26
SS1 S3232F TS28
SS10 S1010 TS3
SS2 S3232F TS4
SS3 S2626F TS5
SS4 S1326F TS6
SS5 S1616F TS7
SS6 S32F TS8
SS7 S1313F TS9
CPS10 PSC25F SS8 S3232F
BORAL PLASTERBOARD | February 2009 D4. 1