Digital Slit Lamp
SL-D701
SL-D701 DIGITAL SLIT LAMP
LED light source
sharp, bright and homogeneous illumination
SL-D701 WITH LED AND HALOGEN LIGHT SOURCE* » Blue free filterTM system for superior fluorescent
» Illumination boost
» New DC-4 digital camera viewing
» New BG-5 LED back ground illumination **
• High resolution
• Meibomian gland observation capability
• Smart capture function
• Still Image with auto exposure function
• Seamless integration
• Infra Red sensitivity
* Factory option
** Fluo model
ADVANTAGES & BENEFITS OF LED
LED LIGHT SOURCE
The new LED illumination source allows observation under a brighter, more homogeneous condition than the
conventional halogen bulb source. The short wavelength of the LED spectrum enables the operator to see minute
details such as flare in the anterior chamber and vitreous. Color temperature remains uniform when adjusting light
intensity insuring consistent viewing results throughout the entire eye’ s optical path.
LED FEATURES
» Brighter illumination enhances observation of the
eye structures
» LED wavelength characteristics allow for easy
visualization of subtle details such as flare and
inflammation
» Consistent color temperature throughout the entire
light intensity adjustment
» Substantial reduction in bulb replacement
» Energy efficient and cost saving
DC-4
Digital camera
SMART CAPTURE FUNCTION LIVE VIEW
With a simple push of the joystick trigger the operator When using the external PC software in conjunction
can obtain a rapid series of images that are quickly with the DC-4, a real time live image will be seen on the
saved for later revision and selection. The Smart monitor to facilitate centering and focusing. The live
Capture function minimizes failed images or blurry image can be used to show the eye condition to third
pictures, especially with children and in conditions of party individuals for teaching and education.
excessive blinking. Sensitivity, shutter speed and white balance can be
adjusted from the computer.
STILL IMAGE WITH AUTO EXPOSURE
(AE) FUNCTION VIDEO CAPABILITY
By adjusting the shutter speed and sensor gain, the The DC-4 allows for easy acquisition of video clips of
brightness of the image will be automatically the eye movements without interfering with the
compensated. As a result the live image used for examination.
alignment and the final picture will have the same color
balance.
ADDITIONAL FILTERS
BLUE FREE FILTERTM SYSTEM
Topcon Blue Free Filter observation can be carried out using the exciter* filter for slit lamp and barrier* filter for slit
lamp. Tear flow details and scars can be clearly viewed with less glare or pooling.
* Fluo model
Blue Free FilterTM Cobalt Blue Filter
Blue Free FilterTM Blue Free FilterTM
Images provided by Toru Noda, MD, PhD, Department of Ophthalmology, Tokyo Medical Center
AMBER FILTER
A warmer, more pleasant tone of the skin and eye structures can be obtained by inserting the amber filter. This
color correction filter produces a pleasant coloration that is especially useful in slit lamp imaging.
Amber Non Amber
MEIBOMIAN GLAND OBSERVATION &
OTHER FEATURES
MEIBOMIAN GLAND OBSERVATION
Meibomian gland observation can be performed and documented using the optional meibomian gland observation
system*. Because of the high resolution of the DC-4, fine detail of glandular acinus and subtle changes of
meibomian glands can be seen and photographed for a better understanding of its condition.
* System of SL-D701 +DC-4 (optional) + BG-5 (optional)
MEIBOSCORE: GRADE 0 ~ 3
Grade 0 Grade 1
Grade 2 Grade 3
MEIBOMIAN GLAND CLOSE-UP! Meibomian Gland
Dropout
* Images and meiboscore provided by: Reiko Arita, MD, PhD, Itoh Clinic,
Department Ophthalmology, the University of Tokyo School of Medicine
RIGHT / LEFT EYE INDICATOR
When in photography mode, the SL-D701 automatically
recognizes the patient's right and left eye, simplifying the photographic
procedure.
MORE THAN JUST THE BASIC FUNCTION
Versatile lens coatings, including a preservative layer, and the use of
apochromatic optics enhance the observation and require less
maintenance.
SYSTEM CHART
Applanation Observation
Tonometer Tube
Model R900
TV Relay Lens Monitor TV Still Video Printer
bayonet mount 1/2 Recorder
TOPCON product Tonometer Mount Beam Video
Products of other SO-TM1 Splitter Camera
1/2 TV Camera TV
Relay Lens
C mount 1/2
TV Relay Lens TV
TL-54 (1/2C) Relay Lens
SONY C mount 1/3
DXC-390/-C33
Iris Diaphragm
SO-DF01
Background Illumination Yellow Filter TV Relay Lens
BG-5 TL-55 (1/3C)
Hruby Lens Parallel IMAGEnet
Panasonic binoculer Tubes
GP-KS162 PB-2 12.5X Eyepiece
The one there is no click but
TV ATT Dedital Camera with measurement scale.
TL-57
12.5X Eyepiece
1/2C Video The one there is click, and
Camera (Adapter Lens) without scale.
TV ATT 12.5X Eyepiece
TL-56 The one there is click, and
with scale.
Adapt Cover Digital Camera Unit
SO-AC 6 DC-4 12.5X Eyepiece
Adapt Cover The one there is click, and
SO-AC 7 with measurement scale.
20X Eyepiece
AUXILIARY SPRING
SO-AS1, 2, 3
PATIENT HANDLE PG-1
CHIN REST CHIN REST CHIN REST
SO-CR03 SO-CR03F SO-CR03P
SL-D701
Digital slit lamp
* Shown with optional DC-4 digital attachment, optional
handle bars and optional electric table.
Specifications Galileo type
Drum, 5-step magnification
Microscope unit
Type 6/10/16/25/40
Magnification 6.37 (ø35.1mm)
Magnification steps 9.94 (ø22.5mm)
Overall magnification (actual vision field) 15.87 (ø14.1mm)
25.37 (ø8.8mm)
Eyepiece lens Magnification 39.62 (ø5.6mm)
Diopter adjustment range
Binocular tubes 12.5x
Illumination unit Slit width -5D to +5D
Illumination field Slit length PD adjustment: 55 to 78mm
Aperture diameter
Slit direction 0 to14mm, can be altered gradually(14mm=circle)tion)
14 to1mm, can be altered gradually(14mm=circle)
Filter ø14, 10, 5, 2, 1, 0.2 mm
Vertical to horizontal, can be altered gradually
Illumination lamp Halogen type: Inclination: 5°/10°/15°/20°
LED type: Side swing
Blue filter, red-free filter, amber filter,
Base unit
UV cut filter (normal use), IR cut filter (normal use),
Forward-backward movement ND filter (13% transmission), exciter filter for slit lamp*,
Right-left movement barrier filter for slit lamp*
12V, 30W
Vertical movement 3A, 10W
Amount of movement in all directions 90mm
100mm
Chinrest unit 30mm
12mm
Amount of vertical movement of chinrest
80mm
Fixation target ** Fixation target with diopter adjustment
Fixation lamp w/Table Luminous fixation target
Other Specifications w/ Unit Table LED (Red)
Dimensions w/o Table
w/o Table and Chinrest 550mm(W) x 420mm(D) x 752 to 782mm(H)
Power Supply Weight: w/Table 440mm(W) x 397mm(D) x 752 to 782mm(H)
w/ Unit Table 329mm(W) x 396mm(D) x 652 to 682mm(H)
w/o Table 329mm(W) x 331(304)mm(D) x 652 to 682mm(H)
w/o Table and Chinrest
Table size 19kg
Unit Table size 18kg
Height from the top to patient’s eye 13kg
11.5kg
550mm x 370mm
440mm x 350mm
375mm
100-240V AC, 50-60Hz, 110VA
* PC and Camera sold seperately.
IMIUnnPcitOoemdRpSTlitaAanteNcseTowfiAthmIStnheuerobictrjeaedr,ctmehtrissttooopfrcoothhdbeautcnEatgxinmpeoatirhynteAndodbetmesbsiinegtinsartevraaasntiuliadoltbn/sloeRwreinsigtpsuheolatmcthiioefiisncreiaongtfsiiotothnrneussmowreicntohtu,onputrlteieaasds.evabnecseudrenototicree.view all user instructions prior to operation.
Topcon Europe Medical B.V. Topcon España S.A. Topcon Deutschland GmbH Topcon Ireland
Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145;
HEAD OFFICE; Frederic Mompou, 4; Hanns-Martin-Schleyer Strasse 41; Unit 276, Blanchardstown; Corporate Park 2
ToEP2p9shs0ocen0boeaA:naC+n3EC11-1au(;p02re)9ol1l00ep8-a4Le/5dJ8MCI5J0aseps7ee7dll;l;eiFTcaahxa/ed:lN+IJB3es1ts-h.e(Ve0l;r.)lPa1.0nO-d.4sB5o8x5014455;
P2E9h-0mo0naeAil::C+m3Ce1ad-p(i0ec)la1lel0@a-4t/do58pIJ5cs0os7ne7.le;;uTF;hawex:wN+we3t.1hto-e(p0rl)ca1on0nd-s-4m58e5d0ic4a5l.eu 08960 S+a3n4t-9J3u-s4t7D3e4s0v5e7rn;T;FBaoVxapi:rac+clee3loo4dn-en9all3’, II-Snt4pda7au3lisyn3tr9ia3260; D-47877 Willich, Germany Toupl. WcBPoaharolsnlynzcaePow: o+sol3kin5la;s32D-k31u8;ab94l72iSn5-491p7500,.0ISrz;eiFelaoawnxi.ed:or+z3.;5P3o-l1a8n2d93915 Item code: 5213571 / printed in Europe 11.13
Phone: Phone: (+49) 2154-885-0; Fax: (+49) 2154-885-177
E-mail: medical@topcon.eu; www.topcon.eu
E-mail: medica@topcon.es; 2Pw0hw0ow3n7e.t:oP+pa3cd9oe-nr0n.2eo-s9D1u8g6n6a7n1o;,F(aMxI:)+It3a9ly-02-E9-1m0a8i1l:0m91ed@topcon.de; www.topcon.de wPhwowEn.-etom:p+ac4iol8:n-m-(p0eo)3dls2ikc-aa6.l7p@0l -t5o0p-c4o5n; .Fiea;xw: +w4w8-.t(o0)p3c2o-n67.ie1-34-05
ToPTPprroaaceepssottecenmmoaDanrrkkassvDnveejmaj225n5a;;m4r40k00a00r0RkoRsoksilkdield, eD,aDnamnamrkark E-mail: topconitaly@tiscali.it; www.topcon
PEwPEh--hwmmoownana.etieilo:l:::pi+n+icn4f4oof5on5@-d@-44at6ot6n-op3m-pc32aoc72rno57kdn05.dad00kn;a0mFn; amaFxraak:x.r+d:k4k+.d54k-456-4-362-7352575555 Topcon (Great Britain) Ltd.
Topcon Italy Topcon S.A.R.L. de Paris; Topcon Polska Sp. z o.o.
Towpwcwo.tonpcSoncdaannmdairnk.adkvia A.B. Viale dell’ Industria 60; 9258u5l.CWlicahrsyz, aFwrasnkcae23; 42-470 Siewierz; Poland Topcon House; Kennet Side; Bone Lane; Newbury
HEAD OFFICE; 89, rue Berkshire RG14 5PX; United Kingdom
Neongatan 2; P.O. Box 25; 43151 Mölndal, Sweden 20037 Paderno Dugnano, (MPIh)oIntael:y+33-(0)1-41069494; Fax: +33-P(0h)o1n-4e7:3+94082-5(01)32-670-50-45; Fax: +48-(0)32-671-34-05 Phone: +44-(0)1635-551120; Fax: +44-(0)1635-551170
Phone: +39-02-9186671; FaxE: -+m3a9i-l:0t2o-p9c1o0n8@10to9p1con.fr; www.topconw.fwr w.topcon-polska.pl E-mail: medical@topcon.co.uk; www.topcon.co.uk
EPT-homonapeil::cm+o4e6dn-i(c0aS)l3@c1-tao7p1nc0o9dn2.i0sn0e;;aFwvawxiw:a+.t4oA6p-c(o.0Bn)3.s.1e-7109249
ToHNPphEeoAocnnDoegO:na+tFa4FEn6IC-s2(E;0pP;).aF3Or1ñ.e-7Bda1eo0rxiS9c22M.50A;o04m.;3Fp1ao5xu1:,M+4ö4; l6n-d(a0l),3S1w-7e1d0e9n249 E-mail: info@topcon.it; wTwowPH.pthaooncpnncoeso-:nMn(+.ai4tDr9tin)e-2Su1c5th4sle-8cy8eh5r-lS0at;rnFasadsxe: G(4+14m;9D)-b42T71Ho8574p7-8cW85oil-l1inc7h7,(GGerrmeanayt Britain) Ltd. Topcon Ireland
Topcon France E-mail: med@topcon.de; www.topcon.Tdoepcon House; Kennet Side; Bone Lane; Newbury
0E8-9m6a0ilS: manetdJiucsatl@Detospvecronn;.Bsea;rcwewlowna.t,oSppcaoin.se Unit 276, Blanchardstown; Corporate Park 2Ballycoolin;
Dublin 15, IrelandPhone: +353-18975900; Fax: +353-18293915
Phone: +34-93-4734057; Fax: +34-93-4733932 E-mail: medical@topcon.ie; www.topcon.ie
E-mail: medica@topcon.es; www.topcon.es
BAT A1; 3 route de la révoTltoe,p93c2o0n6 SPaiontrDtuengisaCledex Berkshire RG14 5PX; United Kingdom
+to3p3c-o(0n)@1-t4o9p2c1o2n3.2fr3;;wFCPRwahuaxowar:nn.+dateoa3x:pi3d+Fc-e3o(o;5r0ntP1e).-f1o,2r-r641tu-096g-2A9a1,9l2L43-62024.262; ;F2a7x9: 0+-305712-2EP1-hm0o-na9ei3l::8+m748e64d-i(c0a)l@16t3o5p-c5o5n11.2c0o.;uFka, xw: w+4w4.t-o(p0c)1o6n3.c5o-5.u5k1170
Phone: www.topcon.pt
E-mail:
TOTPOCPOCNONEUERUOROPEPEMMEDEDICICAALL B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands,
Phone: +31-(0)10-4585077, Fax: +31-(0)10-4585045, Email: medical@topcon.eu, www.topcon-medical.eu