The art of simplicity
TABLE OF CONTENT
4 ABOUT BIOLINE
COMPANY PROFILE
BIOLINE VISION AND STRATEGY
5 BIOLINE MANUFACTURING LINES
ENGINIRING CAD CAM
STATE OF THE ART ACURATE MACHINING
QUALITY INSPECTION
CLEAN ROOM PACKING
6-10 CONCEPT OF SURFACE TRAEATMENTS
6 BIOLINE DENTAL IMPLANT LINES
8 SPIRAL IMPLANT
10 SPIRAL CONNIE IMPLANT
12 CYLINDRICAL IMPLANT
14 ACTIVE IMPLANT [NEW]
16 BIOLINE IMPLANT
18 ONE PIECE IMPLANT
20 PROSTHETIC PARTS
22 HEALING CUPS
23 STRAIGHT ABUTMENTS
24 15 ANGULATED ABUTMENTS
25 25 ANGULATED ABUTMENTS
26 BALL ATACHMENTS
27 ZIRCONIA ABUTMENTS
28 ZIRCONIA ABUTMENTS WITH TITANIUM BASE
29 TEMPORARY PEEK ABUTMENTS
30 CASTBLE ABUTMENTS
31 IMPRESION COMPONENTS
32 POWER CLICK ATTACHMENT
33 MULTI-UNIT
34 ANGULATED MULTI-UNIT
35 ESTHETIC SCREW ABUTMENT
36 INSTRUMENTS
37 TOOLS
38 STOPPER DRILLS
39 INSTRUMENTS & DRILLS
40 SURGICAL KITS
41 NOTES
Implants | 3
ABOUT BIOLINE
BIOLINE Dental is a worldwide leader in the field of dental implants. The company is a Manufacturer and
distributor of dental implants since 2005 and its implants can be found in Tens of thousands of healed persons
around the world.
BIOLINE Dental is a global strategic manufacturer with leading international distributions partners. We
Manufacture the implants in Eu, United States and distribute them for both the local and international Markets.
Working according to local and international standards, our products are authorized by the leading medical
labs around the world, and are sold in more than 30 countries Including Israel, Europe, North America, India
and more…..
BIOLINE Dental Vision and Strategy
• Creating the highest quality implants, ensuring functional & esthetical solutions, while considering the long
term and high success rate of the implant.
• Create a collection of products to improve the life quality of the patient.
• Continuous improvement and adherence to technological innovation and creativity.
• Production of technological products based on simplicity and long-term benefits to the doctor and the patient.
• Allowing each physician and patient worldwide use innovative product at an affordable price.
Product Range
BIOLINE manufactures six type of dental implants and wide variety of prosthetic parts, as well as using
extremely innovative clean-green surface treatment, one switching platform for all diameters components
which enable the dentist to maintain minimal inventory of prosthetic parts.
Standards-certifications
BIOLINE is committed to the highest level of accuracy and quality control to Produce the Best possible
implants and related products. The company’s products comply with All the requirements of medical devices
standards and are medical iso 13485-2012 & CE 1023 approved.
Customer Service
The company sees its customers with a very Importance all over the world.
The company’s products are marketed worldwide through authorized resellers.
The company believes in providing support and comprehensive service and support.
We are working constantly to provide information and training to distributors and customers in order to foster a
tradition of ad-lasting quality and excellence.
4 | Bioline
BIOLINE MANUFACTURING LINES
ENGINIRING CAD CAM
Our company specializes in designing computer-aided dental elements
The planning department engineers have extensive experience in many areas
• Computerized mechanical design.
• Strength of materials.
• Simulation of assemblies and subassemblies.
• Metallurgy.
Human engineering and product planning to use a simple stable and comfortable
to the doctor and the patient.
Dental product design requires a comprehensive scientific thinking concerning
mechanical strength of the product and the ability to ensure the survival during
transplantation as well as the creation of a precise-strong connection and resistant to vibration and continuous wear.
We are working on the continuous development of new products and improving existing products to ensure total quality
so as to assure long-term success in improving the patient’s quality of life.
STATE OF THE ART ACURATE MACHINING
Our company has a modern factory with high quality computerized machines
very secure continuous and repeatable accuracy.
Manufacturing operations based on a computerized manufacturing system
and program management and monitoring of the different jobs and Very
strict production process, controlled by skilled workers with knowledge and
experience.
QUALITY INSPECTION
Our company manufactures medical-dental products during application and adaptation most
stringent workmanship standards in the industry.
The company’s products are tested in the production process and in the transition between the
various productions stages by qualified Inspectors in accordance with the specifications defined
of production procedures.
Our company is certified to iso13485-2012 and carries the CE-1023 icon.
Our company is working constantly to improve the quality policy and ensuring maximum quality
level of the company’s products, all to ensure excellent products And customer satisfaction.
CLEAN ROOM PACKING
Packaging process is done in a clean room ensures purification level specified
by the medical device for dental implants.
Packaging room environment ensures hygiene product during the sterile
packaging and ensuring long shelf life without any possible contamination of
the product
This room clean environment suitable for international labor standards defined
in the CE standard.
Bioline | 5
Ordering Information
Reservation form of the Company’s products is done in a simple manner according to the illustration below
and the attached color-coded and lengths below.
For more information or questions are asked to please contact: info@bioline-implants.de
Product name Date of sterilization products Bi-3 3.75 10
Type Tracking dose
Parameters, sizes Type / aticle (by catalog of manufacturer) Bi-3-3.75-10
Manufacturer Check the manuel BIOLINE Dental Implants Systems 1023
For single use only This product is sterilized by gama radiation
PLATZ DER EINHEIT 1, FRANKFURT, HESSEN 60327 GERMANY, OFFICE: +49 69 97 503 415
www.biowliwnwe-.inmfinpiltayn.ctosm.de
Implants Spiral Spiral Cone Bioline One Piece
Slim Conical connection
3.75 3.75 3.75 3.75
* All dimensions are in millimeters ** All the implants manufactured oftitanium (Grade 5)
6 | Bioline
Our Dental Collection
Bioline | 7
Spiral Implant
Our spiral implant is a unique product based on traditional and proven Anti Bacteirial Anodize Coating
design of tapered implant threaded balanced and dynamic self-drilling
capability. Outstanding tapered implant symmetrical structure that Condensing High Theards
contributes to balance efforts and equal distribution of possible loads Anti-unscrewing Groove
during implantation and for the duration of use.
Internal hex connection
This series of implants with internal hex connection very high precision
mechanical strength and guarantees long durability.
Implant Structure
The implant is built strong and stable body with durable blades that collect at
the corners convene the soft bone and compressing it during implantation
to ensure the uniform and high-quality platform for connecting the bone
graft. The implants are equipped with uniform connection platform that
allows the use of identical parts of rehabilitation after transplantation.
Anodized coating technology unique anti-bacterial process.
The implants undergo anodized coating process which contributes to
creating anti-bacterial shell on titanium raw. The coating is made from
natural ingredients Food Standard \ Medicine and unattended polluting
industrial materials. Anodized great extent contributes to the mechanical
strength and maintaining internal connection implant restoration parts and
prevents friction between bare metal, this procedure ensures long-term
success of rehabilitation on implants.
Self Drilling Law Theards
Surface treatment unique approach
Our company has adopted the method of surface treatment based on
technology SLA or the RBM using quality materials to create Topography
required on the one hand and on the other hand has chosen , principle,
not to use chemicals and industrial pollutants which the results in their
use may be harmful after months \years during the break-up of chemicals.
The company decided to use citric acid seem natural stabilized as a key
component in the process of removing residues media which was sprayed
on a dental implant during surface treatment .
The use of acid seem natural ensures that the implant will be absorbed
very well and that will avoid situations of rejection of implants resulting
from acid treatment consisting of aggressive industrial chemicals that
have the feature break-up after a certain period.
This process is unique to our company and is based on years of
experience and hundreds of thousands of implants manufactured and
implanted around the world.
8 | Bioline
Length Dia 3.30 3.75 4.20 5.00 6.00
BIO-F3706 BIO-F4206 BIO-F5006 BIO-F6006
6.00 BIO-F3308 BIO-F3708 BIO-F4208 BIO-F5008 BIO-F6008
8.00 BIO-F3310 BIO-F3710 BIO-F4210 BIO-F5010 BIO-F6010
10.00 BIO-F3311 BIO-F3711 BIO-F4211 BIO-F5011 BIO-F6011
11.50 BIO-F3313 BIO-F3713 BIO-F4213 BIO-F5013 BIO-F6013
13.00 BIO-F3316 BIO-F3716 BIO-F4216 BIO-F5016
16.00
Drilling protocol
The recommendations presented in this drilling Protocol, based on long experience of specialists in the world. However it is
important to examine each case on its merits based on the physician’s ability to perform the procedure, and the state of the
patient’s jaw implant transpires with the beginning and there may be changes according to the situation.
In principle, we recommend using a drill that its diameter smaller than the diameter of the implant, in the case of soft bone
condition. Also, consider using a similar drill diameter implant intended for implantation in the case of hard bone in order to avoid
trauma to the bone and ensure rapid bone building around the implant.
Ø 2.0 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.1 Ø 4.5 Ø 4.8 Ø 5.2 Ø 5.8
Ø 3.3 Soft Bone
Hard Bone
Ø 3.75 Soft Bone
Hard Bone
Ø 4.2 Soft Bone
Hard Bone
Ø 5.0 Soft Bone
Hard Bone
Ø 6.0 Soft Bone
Hard Bone
Throughout entire implant's length In cases of a hard bone drill through the cortical layer
Bioline | 9
Spiral Connie Implant
Innovative implant is based on the successful series of Our company’s Anti Bacteirial Anodize Coating
original spiral implant. The design of the upper part of the implant is Conical Top
formed mainly for aesthetic reasons. Upper conical portion helps prevent Condensing High Theards
regression of bone and supports geometric rebuilding of restoration parts Anti-unscrewing Groove
on the implant above the gum line.
Internal hex connection
This series of implants with internal hex connection very high precision
mechanical strength and guarantees long durability.
Implant structure
Inventive Thinking
The implant is built strong and stable body with durable blades that
collect at the corners convene the soft bone and compressing it during
implantation to ensure the uniform and high-quality platform for connecting
the bone graft.
The implants are equipped with uniform connection platform that allows
the use of identical parts of rehabilitation after transplantation.
Anodized coating technology unique anti-bacterial process.
The implants undergo anodized coating process which contributes to
creating anti-bacterial shell on titanium raw. The coating is made from
natural ingredients Food Standard \ Medicine and unattended polluting
industrial materials. Anodized great extent contributes to the mechanical
strength and maintaining internal connection implant restoration parts and
prevents friction between bare metal, this procedure ensures long-term
success of rehabilitation on implants.
Surface treatment unique approach Self Drilling Law Theards
Our company has adopted the method of surface treatment based on
technology SLA or the RBM using quality materials to create Topography
required on the one hand and on the other hand has chosen , principle,
not to use chemicals and industrial pollutants which the results in their
use may be harmful after months \years during the break-up of chemicals.
The company decided to use citric acid seem natural stabilized as a key
component in the process of removing residues media which was sprayed
on a dental implant during surface treatment .
The use of acid seem natural ensures that the implant will be absorbed
very well and that will avoid situations of rejection of implants resulting
from acid treatment consisting of aggressive industrial chemicals that
have the feature break-up after a certain period.
This process is unique to our company and is based on years of
experience and hundreds of thousands of implants manufactured and
implanted around the world.
10 | Bioline
Length Dia 4.20 5.00 6.00
BIO-F4306 BIO-F6106
6.00 BIO-F4308 BIO-F5108 BIO-F6108
8.00 BIO-F4310 BIO-F5110 BIO-F6110
10.00 BIO-F4311 BIO-F5111 BIO-F6111
11.50 BIO-F4313 BIO-F5113 BIO-F6113
13.00 BIO-F4316 BIO-F5116
16.00
Drilling protocol
The recommendations presented in this drilling Protocol, based on long experience of specialists in the world. However it is
important to examine each case on its merits based on the physician’s ability to perform the procedure, and the state of the
patient’s jaw implant transpires with the beginning and there may be changes according to the situation.
In principle, we recommend using a drill that its diameter smaller than the diameter of the implant, in the case of soft bone
condition. Also, consider using a similar drill diameter implant intended for implantation in the case of hard bone in order to avoid
trauma to the bone and ensure rapid bone building around the implant.
Ø 2.0 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.1 Ø 4.5 Ø 4.8
Ø 3.3 Soft Bone
Hard Bone
Ø 3.75 Soft Bone
Hard Bone
Ø 4.2 Soft Bone
Hard Bone
Ø 5.0 Soft Bone
Hard Bone
Throughout entire implant's length In cases of a hard bone drill through the cortical layer
Bioline | 11
Cylindrical Implant
The company’s implant Cylinder built in order to achieve stability and serve
as an anchor for a stable reconstruction. Implant corrugation delicate and
multi-donor bone compression insertion process, the cylinder implant is
recommended for use in cases of particularly hard bone, but functions
well in other cases.
cylinder Implant is a classic and reliable product for many years.
Easy insertion of the implant in accordance with the recommended drilling
Protocol and the geometric structure ensures long term stability.
Internal hex connection
This series of implants with internal hex connection very high precision
mechanical strength and guarantees long durability.
Inventive Thinking
The implant is built strong and stable body with durable blades that collect at
the corners convene the soft bone and compressing it during implantation
to ensure the uniform and high-quality platform for connecting the bone
graft The implants are equipped with uniform connection platform that
allows the use of identical parts of rehabilitation after transplantation.
Anodized coating technology unique anti-bacterial process.
The implants undergo anodized coating process which contributes to
creating anti-bacterial shell on titanium raw. The coating is made from
natural ingredients Food Standard \ Medicine and unattended polluting
industrial materials. Anodized great extent contributes to the mechanical
strength and maintaining internal connection implant restoration parts and
prevents friction between bare metal, this procedure ensures long-term
success of rehabilitation on implants.
Surface treatment unique approach
Our company has adopted the method of surface treatment based on
technology SLA or the RBM using quality materials to create Topography
required on the one hand and on the other hand has chosen , principle,
not to use chemicals and industrial pollutants which the results in their
use may be harmful after months \years during the break-up of chemicals.
The company decided to use citric acid seem natural stabilized as a key
component in the process of removing residues media which was sprayed
on a dental implant during surface treatment .
The use of acid seem natural ensures that the implant will be absorbed
very well and that will avoid situations of rejection of implants resulting
from acid treatment consisting of aggressive industrial chemicals that
have the feature break-up after a certain period.
This process is unique to our company and is based on years of
experience and hundreds of thousands of implants manufactured and
implanted around the world.
12 | Bioline
Length Dia 3.30 3.75 4.20 5.00 6.00
BIO-G3706 BIO-G4206 BIO-G5006 BIO-G6006
6.00 BIO-G3708 BIO-G4208 BIO-G5008 BIO-G6008
BIO-G3710 BIO-G4210 BIO-G5010 BIO-G6010
8.00 BIO-G3308 BIO-G3711 BIO-G4211 BIO-G5011 BIO-G6011
BIO-G3713 BIO-G4213 BIO-G5013 BIO-G6013
10.00 BIO-G3310 BIO-G3716 BIO-G4216 BIO-G5016
11.50 BIO-G3311
13.00 BIO-G3313
16.00 BIO-G3316
Drilling protocol
The recommendations presented in this drilling Protocol, based on long experience of specialists in the world. However it is
important to examine each case on its merits based on the physician’s ability to perform the procedure, and the state of the
patient’s jaw implant transpires with the beginning and there may be changes according to the situation.
In principle, we recommend using a drill that its diameter smaller than the diameter of the implant, in the case of soft bone
condition. Also, consider using a similar drill diameter implant intended for implantation in the case of hard bone in order to avoid
trauma to the bone and ensure rapid bone building around the implant.
Ø 2.0 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.1 Ø 4.5 Ø 4.8 Ø 5.2 Ø 5.8
Ø 3.3 Soft Bone
Hard Bone
Ø 3.75 Soft Bone
Hard Bone
Ø 4.2 Soft Bone
Hard Bone
Ø 5.0 Soft Bone
Hard Bone
Ø 6.0 Soft Bone
Hard Bone
Throughout entire implant's length In cases of a hard bone drill through the cortical layer
Bioline | 13
Active Implant
Active implant is a unique dental implant developed after thorough Anti Bacteirial Anodize Coating
research related to the ongoing quality of the connection between the
bone and the dental implant. Our development team sought a solution Condensing High Theards
that would extend as far as possible the life of the connection between the Anti-unscrewing Groove
bone and the implant everything to ensure long-term quality restoration Self Drilling Law Theards
or almost infinite. In the development process is taken into consideration
that even if we use the finest dental implant in the world, it is agreed
that this object is a passive metal implant which has no lasting benefit
or active contribution of osteointegration. from this point of view, we
developed Active implant based on our spiral implant line, but hollowed
and with few points of holes in the body, all for the transport or injection of
fluid-gel that contain regeneration ingredients.
Inventive Thinking
As presented in the introduction about the Active family implant. The
goal is to use this unique dental implant as a tool for transporting liquids
and \ or special solutions designed to refresh the soft bone in the jaw.
Special holes at the bottom of the implant body and graft are used for
transporting liquids from the implant after successful implantation process
and indefinitely when the implant is functioning as a basis for dental
rehabilitation on the one hand, and as a tool for conveying the same
fluid causes the processing of soft bone regeneration. This innovative
Active implant is unique and exclusive to our company and reflects
technological innovation and a major breakthrough in relation to prolong
the life of dental implants and extending the medical care sucsess and
life quality of the patient. The proposed maintenance using Active dental
implant \ device contributes to bone reconstruction and revival of the soft
tissues. The procedure involves performing the proposed maintenance
is simple and friendly to the doctor and patient, and is in fact part of the
routine care and maintenance required after dental implants procedure
from time to time.
Surface treatment unique approach
Our company has adopted the method of surface treatment based on
technology SLA or the RBM using quality materials to create Topography
required on the one hand and on the other hand has chosen , principle,
not to use chemicals and industrial pollutants which the results in their
use may be harmful after months \years during the break-up of chemicals.
The company decided to use citric acid seem natural stabilized as a
key component in the process of removing residues media which was
sprayed on a dental implant during surface treatment . The use of acid
seem natural ensures that the implant will be absorbed very well and that
will avoid situations of rejection of implants resulting from acid treatment
consisting of aggressive industrial chemicals that have the feature break-
up after a certain period.
This process is unique to our company and is based on years of
experience and hundreds of thousands of implants manufactured and
implanted around the world.
14 | Bioline
Length Dia 3.30 3.75 4.20 5.00 6.00
BIO-IR4206 BIO-IR5006 BIO-IR6006
6.00 BIO-IR3706 BIO-IR4208 BIO-IR5008 BIO-IR6008
8.00 BIO-IR4210 BIO-IR5010 BIO-IR6010
10.00 BIO-IR3308 BIO-IR3708 BIO-IR4211 BIO-IR5011 BIO-IR6011
11.50 BIO-IR4213 BIO-IR5013 BIO-IR6013
13.00 BIO-IR3310 BIO-IR3710 BIO-IR4216 BIO-IR5016
16.00
BIO-IR3311 BIO-IR3711
BIO-IR3313 BIO-IR3713
BIO-IR3316 BIO-IR3716
Drilling protocol
The recommendations presented in this drilling Protocol, based on long experience of specialists in the world. However it is
important to examine each case on its merits based on the physician’s ability to perform the procedure, and the state of the
patient’s jaw implant transpires with the beginning and there may be changes according to the situation.
In principle, we recommend using a drill that its diameter smaller than the diameter of the implant, in the case of soft bone
condition. Also, consider using a similar drill diameter implant intended for implantation in the case of hard bone in order to avoid
trauma to the bone and ensure rapid bone building around the implant.
Ø 2.0 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.1 Ø 4.5 Ø 4.8 Ø 5.2 Ø 5.8
Ø 3.3 Soft Bone
Hard Bone
Ø 3.75 Soft Bone
Hard Bone
Ø 4.2 Soft Bone
Hard Bone
Ø 5.0 Soft Bone
Hard Bone
Ø 6.0 Soft Bone
Hard Bone
Throughout entire implant's length In cases of a hard bone drill through the cortical layer
Bioline | 15
BioLine Implant 1ST Micro Thread
2ND Micro Thread
This dental implant is a concept based on the popular series of familiar
BIOLINE spiral conical implants. The Conical structure of the implant, 3RD Micro Thread
single-threaded and self-drilling head of the implant identical conical-
spiral implant very successful, and the company’s best-selling in recent
years.
Alongside the success of this dental implant and as a result of careful
thought on the part of our development team in the company and
recommendations of researchers from medical institutions, large and
well known, all over Europe and abroad, BIOLINE decided to develop
and produce a series of implants Which are based on computerized
mechanical corrugation which increases the surface of the implant and
inviting quality morphology creates excellent conditions for integration
between the implant to the bone. The uniqueness is that conditions are
produced by corrugation of the implant computerized machine during
production using special blades that were developed for this purpose.
The result is a pure dental implant, manufactured from, Medical Grade
5 titanium missing from chemical treatments, chemical etching, rinsing
industrial soaps and aggressive acids that may chemically decompose
within a short time, and produce inflammation and risk of emission of the
implants.
Inventive Thinking
To encourage bone growth around this unique implant and creating
Osseo integration quantitative and qualitative, the company developed
with Ghimas S.p.A this unique gel, SLURRY is a physical form
characterized by a micro dispersion of solids in a gel. This is due to the
ultra microstructure of the solid which, being in a sufficient amount of
liquid, cannot settle, with complex physical interactions between the solid
particles surrounded by hydrophilic molecules and forces of chemical
attraction keeping the product fluid and cohesive.
From a biological standpoint, the SLURRY ensures better bio-compatibility
for more harmonious degradation of the polymer and copolymer and
of the co-formulates, which are therefore more easily degraded by the
organism using normal metabolic systems (e.g. the Krebs cycle).
The unique combination of pure titanium implant with mechanical
roughening without spraying substances that cause infection on the one
hand, and on the other hand use of this unique wave is breaking scientific
way of thinking.
Proven clinical experience of using these implants in recent years testifies
to the success and consistency of the proposed process benefits.
16 | Bioline
Length Dia 3.30 3.75 4.20 5.00 6.00
BIO-BI3706 BIO-BI4206 BIO-BI5006 BIO-BI6006
6.00 BIO-BI3308 BIO-BI3708 BIO-BI4208 BIO-BI5008 BIO-BI6008
8.00 BIO-BI3310 BIO-BI3710 BIO-BI4210 BIO-BI5010 BIO-BI6010
10.00 BIO-BI3311 BIO-BI3711 BIO-BI4211 BIO-BI5011 BIO-BI6011
11.50 BIO-BI3313 BIO-BI3713 BIO-BI4213 BIO-BI5013 BIO-BI6013
13.00 BIO-BI3316 BIO-BI3716 BIO-BI4216 BIO-BI5016
16.00
Drilling protocol
The recommendations presented in this drilling Protocol, based on long experience of specialists in the world. However it is
important to examine each case on its merits based on the physician’s ability to perform the procedure, and the state of the
patient’s jaw implant transpires with the beginning and there may be changes according to the situation.
In principle, we recommend using a drill that its diameter smaller than the diameter of the implant, in the case of soft bone
condition. Also, consider using a similar drill diameter implant intended for implantation in the case of hard bone in order to avoid
trauma to the bone and ensure rapid bone building around the implant.
Ø 2.0 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.1 Ø 4.5 Ø 4.8 Ø 5.2 Ø 5.8
Ø 3.3 Soft Bone
Hard Bone
Ø 3.75 Soft Bone
Hard Bone
Ø 4.2 Soft Bone
Hard Bone
Ø 5.0 Soft Bone
Hard Bone
Ø 6Ø.06.0 Soft Bone
Hard Bone
Throughout entire implant's length In cases of a hard bone drill through the cortical layer
Bioline | 17
One Piece Implant
This implant is a single unit containing a body comprising an implant and
a straight structure.
The implant is made of 3 mm diameter 3.3 mm and 3.75 mm.
This implant is designed specifically for use in a narrow ridge and narrow
place between teeth.
The implant is for immediate loading because of its uniform structure, this
implant coated with anti-bacterial anodized gold colored.
The surface of the implant treated the same way in which the treatment is
carried out at all our implants series.
Surface treatment unique approach
Our company has adopted the method of surface treatment based on
technology SLA or the RBM using quality materials to create Topography
required on the one hand and on the other hand has chosen , principle,
not to use chemicals and industrial pollutants which the results in their
use may be harmful after months \years during the break-up of chemicals.
The company decided to use citric acid seem natural stabilized as a key
component in the process of removing residues media which was sprayed
on a dental implant during surface treatment .
The use of acid seem natural ensures that the implant will be absorbed
very well and that will avoid situations of rejection of implants resulting
from acid treatment consisting of aggressive industrial chemicals that
have the feature break-up after a certain period.
This process is unique to our company and is based on years of
experience and hundreds of thousands of implants manufactured and
implanted around the world.
18 | Bioline
Length Dia 3.00 3.30 3.75
BIO-P3010 BIO-P3310 BIO-P3710
10.00 BIO-P3011 BIO-P3311 BIO-P3711
11.50 BIO-P3013 BIO-P3313 BIO-P3713
13.00 BIO-P3016 BIO-P3316 BIO-P3716
16.00
Drilling protocol
The recommendations presented in this drilling Protocol, based on long experience of specialists in the world. However it is
important to examine each case on its merits based on the physician’s ability to perform the procedure, and the state of the
patient’s jaw implant transpires with the beginning and there may be changes according to the situation.
In principle, we recommend using a drill that its diameter smaller than the diameter of the implant, in the case of soft bone
condition. Also, consider using a similar drill diameter implant intended for implantation in the case of hard bone in order to avoid
trauma to the bone and ensure rapid bone building around the implant.
16 mm
13 mm
11.5 mm
10 mm
8 mm
6 mm
0 mm Tip 0 mm
length*
Ø 1.4 Ø 2.0 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.1 * For the drills Ø 2.0, Ø 2.8, Ø 3.2, Ø 3.65, Ø 4.1
the apical height is included in the
drill depth calculation
Ø 3.0
Important!
For the drill Ø 1.4 the apical height is not included
in the drill depth calculation (see page 92 for
Ø 3.3 more information).
Ø 3.6
Ø 4.2
Ø 5.0 Throughout entire implant's length
In case of a hard bone
Bioline | 19
Perfect collection
of Prosthodontics parts
A comprehensive solution for all clinical cases
Healing Cups
Diameter
3.8 mm Slim
Cat No. BIO-H3802 BIO-H3803 BIO-H3804 BIO-H3805 BIO-H3806 BIO-H3807
Height 2.00 mm 3.00 mm 4.00 mm 7.00 mm
5.00 mm 6.00 mm
Diameter BIO-H4602 BIO-H4603 BIO-H4604 BIO-H4605 BIO-H4606 BIO-H4607
4.6 mm 4.00 mm 7.00 mm
Standart 2.00 mm 3.00 mm 5.00 mm 6.00 mm
Cat No.
Height
Diameter BIO-H5502 BIO-H5503 BIO-H5504 BIO-H5505 BIO-H5506 BIO-H5507
5.5 mm 4.00 mm 7.00 mm
Wide 2.00 mm 3.00 mm 5.00 mm 6.00 mm
Cat No.
Height
Diameter BIO-H6303 BIO-H6304 BIO-H6305 BIO-H6306 BIO-H6307 BIO-H6308
6 mm 5.00 mm 8.00 mm
Wide 3.00 mm 4.00 mm 6.00 mm 7.00 mm
Cat No.
Height
22 | Bioline
Straight Abutments
Straight BIO-A5908 BIO-A5909 BIO-A5911 BIO-A5912 BIO-A5601 BIO-A5602
Abutment 8.5 mm 9.5 mm 11.5 mm 12.5 mm 8.5 mm 10.5 mm
Cat No.
Height
Straight BIO-A4801 BIO-A4802 BIO-A4803 BIO-A4804 BIO-A5001 BIONo-nA-H5e0x 02
Shoulder 8.5 mm 9.5 mm 10.5 mm 11.5 mm 9.5 mm 9.5 mm
Abutment 1.00 mm 2.00 mm 3.00 mm 4.00 mm 1.70 mm 1.70 mm
Cat No.
Height
Shoulder
Straight BIO-A5300 BIO-A5301 BIO-A5302 BIO-A6006 BIO-A6008 BIO-A6011
Shoulder 8.5 mm 8.5 mm 8.5 mm 6.00 mm 8.00 mm 11.00 mm
Narrow 0.50 mm 1.50 mm 2.50 mm
Abutment N/A N/A N/A
Cat No.
Height
Shoulder
Straight BIO-A4601 BIO-A4602 BIO-A4603 BIO-A4604 Screw for abutment
Anatomic 9.00 mm 10.00 mm 11.00 mm 12.00 mm
Abutment 1.00 mm 2.00 mm 3.00 mm 4.00 mm BIO-S8324
Cat No. Included with all
Height types of abutments
Shoulder
Bioline | 23
150 Angulated Abutments
150 Standart BIO-A3207 BIO-A3208 BIO-A3209 BIO-A3211
Abutment 7 mm 8.5 mm 9 mm 11 mm
Cat No.
Height
150 Narrow BIO-A2807 BIO-A2809 BIO-A2811 150 Narrow BIO-A3609
Top Standart 7 mm 8.5 mm 9 mm Standart 9 mm
Abutment Abutment
Cat No. Cat No.
Height Height
150 Anatomic BIO-A2400 BIO-A2401 BIO-A2402 BIO-A2403 BIO-A2404
Standart 8.5 mm 9.5 mm 10.5 mm 11.5 mm 12.5 mm
Abutment 0.80 mm 1.00 mm 2.00 mm 3.00 mm 4.00 mm
Cat No.
Height
Shoulder
Screw for abutment
BIO-S8324
Included with all
types of abutments
24 | Bioline
250 Angulated Abutments
250 Standart BIO-A3407 BIO-A3409 BIO-A3411
Abutment 7 mm 9 mm 11 mm
Cat No.
Height
250 Narrow
Top Standart
Abutment
Cat No. BIO-A3007 BIO-A3009 BIO-A3011
Height 7 mm 9 mm 11 mm
250 Anatomic 250 Narrow
Standart Standart
Abutment Abutment
Cat No.
Cat No. BIO-A2601 BIO-A2602 BIO-A2603 BIO-A2604 Height BIO-A3809
Height 9.5 mm 10.5 mm 11.5 mm 12.5 mm 9 mm
Shoulder 1.00 mm 2.00 mm 3.00 mm 4.00 mm
Screw for abutment
BIO-S8324
Included with all
types of abutments
Bioline | 25
Ball Attachment
Metal Cap BIO-T3001
For Ball
Attachment
Cat No.
Ball
Attachment
Cat No. BIO-T3002 BIO-T3003 BIO-T3004 BIO-T3005
Silicone Extra soft Silicone soft Silicone standart Peek
Caps 2.5mm BIO-T1200 BIO-T1201 BIO-T1202 BIO-T1203 BIO-T1204 BIO-T1205 BIO-T1206 BIO-T1207
for Ball 0.5 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm
Attachment
Cat No.
Height
26 | Bioline
Zirconia Abutments
Zirconia BIO-Z4502 Zirconia BIO-Z4505 BIO-Z4510 BIO-Z4520 BIO-Z4530
Narrow 9 mm Straight 8.5 mm 9 mm 10 mm 11 mm
Straight Anatomic 0.50 mm 2.00 mm 3.00 mm
Abutment 2.00 mm Abutment 1.00 mm
Cat No. Cat No.
Height Height
Shoulder Shoulder
150 BIO-Z4509 150 BIO-Z2400 BIO-Z2401 BIO-Z2402 BIO-Z2403
Zirconia 9.5 mm Zirconia 9.5 mm 9.5 mm 10.5 mm 11.5 mm
Standart Anatomic 0.50 mm 1.00 mm 2.00 mm 3.00 mm
Abutment Abutment
Cat No.
Height Cat No.
Height
Shoulder
250 BIO-Z2601 BIO-Z2602 BIO-Z2603 BIO-Z2604 Screw for abutment
Zirconia 9.5 mm 9.5 mm 10.5 mm 11.5 mm
Anatomic 0.50 mm 1.00 mm 2.00 mm 3.00 mm BIO-S8324
Abutment
Included with all
Cat No. types of abutments
Height
Shoulder
Bioline | 27
Titanium Base
Zirconia Abutments
Zirconia BIO-ZB4502 Zirconia BIO-ZB4505 BIO-ZB4510 BIO-ZB4520 BIO-ZB4530
Narrow 9 mm Straight 8.5 mm 9 mm 10 mm 11 mm
Straight Anatomic 0.50 mm 2.00 mm 3.00 mm
Abutment 2.00 mm Abutment 1.00 mm
Cat No. Cat No.
Height Height
Shoulder Shoulder
150 BIO-ZB4509 150 BIO-ZB2400 BIO-ZB2401 BIO-ZB2402 BIO-ZB2403
Zirconia 9.5 mm Zirconia 9.5 mm 9.5 mm 10.5 mm 11.5 mm
Standart Anatomic 0.50 mm 1.00 mm 2.00 mm 3.00 mm
Abutment Abutment
Cat No. Cat No.
Height Height
Shoulder
250 BIO-ZB2601 BIO-ZB2602 BIO-ZB2603 BIO-ZB2604
Zirconia 9.5 mm 9.5 mm 10.5 mm 11.5 mm
Anatomic 0.50 mm 1.00 mm 2.00 mm 3.00 mm
Abutment
Cat No.
Height
Shoulder
Titanium BIO-ZB8326 BIO-ZB8327 Screw for abutment
Base For 4.3 mm 4.3 mm
Individual 3.5 mm 3.5 mm BIO-S8324
Zirconia Hexed
Abutment Non-Hexed Included with all
types of abutments
Cat No.
Height
Shoulder
28 | Bioline
Temporary Peek Abutments
Peek BIO-P4510 BIO-P4520 BIO-P4530
Straight 9 mm 10 mm 11 mm
Anatomic 2.00 mm 3.00 mm
Abutment 1.00 mm
Cat No.
Height
Shoulder
150 Peek 1.00 mm 2.00 mm 3.00 mm
Anatomic
Abutment BIO-P2401 BIO-P2402 BIO-P2403
9 mm 10 mm 11 mm
Cat No. 2.00 mm 3.00 mm
Height 1.00 mm
Shoulder
250 Peek BIO-P2601 BIO-P2602 BIO-P2603 Screw for abutment
Anatomic 9 mm 10 mm 11 mm
Abutment BIO-S8324
Cat No. Included with all
Height types of abutments
Shoulder
Bioline | 29
Castable Abutments
Castable BIO-C4510 BIO-C4520 BIO-C4530
Straight 9 mm 10 mm 11 mm
Anatomic 2.00 mm 3.00 mm
Abutment 1.00 mm
Cat No.
Height
Shoulder
150 BIO-C2401 BIO-C2402 BIO-C2403
Castable 9 mm 10 mm 11 mm
Anatomic 2.00 mm 3.00 mm
Abutment 1.00 mm
Cat No.
Height
Shoulder
250 BIO-C2601 BIO-C2602 BIO-C2603
Castable 9 mm 10 mm 11 mm
Anatomic 2.00 mm 3.00 mm
Abutment 1.00 mm
Cat No.
Height
Shoulder
Custom BIO-C2001 BIO-C2003 BIO-C2004 Custom BIO-C1001 BIO-C1002
Castable UCLA NON-HEX HEX Castable
Abutment Narrow
Cat No. Abutment
Cat No.
NON-HEX HEX
Screw for abutment
BIO-S8324
Included with all
types of abutments
30 | Bioline
Impression Components
Transfer For
Open Tray
Cat No. BIO-T4008 BIO-T4201 BIO-T4212
Diameter 4.75 mm 4.30 mm 4.75 mm
Height 8.00 mm 12.00 mm 12.00 mm
Transfer BIO-T3507 BIO-T3511 BIO-T3601 Screw for BIO-S2418
For Close 3.85 mm 4.50 mm 4.75 mm Transfer 24.00 mm
Tray 12.00 mm 12.00 mm 8.00 mm
Cat No.
Cat No. Height
Diamter
Height
Click BIO-T3409 BIO-T3413 BIO-T4012 Screw for BIO-S1307 BIO-S1610
Transfer 4.70 mm 4.70 mm 4.80 mm Transfer 13.00 mm 16.00 mm
For Close 9.00 mm 13.00 mm 11.80 mm
Tray Cat No.
Height
Cat No.
Diameter
Height
Ball BIO-T3801 BIO-T3802 BIO-T3803 BIO-T3804 BIO-T3805
Transfer 4.75 mm 4.75 mm 4.75 mm 4.75 mm 4.75 mm
Cat No. 1.00 mm 2.00 mm 3.00 mm 4.00 mm 5.00 mm
Diameter
Shoulder
Plastic Cap BIO-T4401 BIO-T4402 Implant BIO-T6404 BIO-T6405
For Ball 4.75 mm 4.75 mm Analog 4.00 mm 5.00 mm
Transfer 7.00 mm 10.00 mm 12.75 mm 12.75 mm
Cat No.
Cat No. Diameter
Diameter Height
Height
Bioline | 31
Power Click Attachmet
Power Click BIO-PCA01 BIO-PCA03 BIO-PCA04 BIO-PCA05
Straight
Abutment
Cat No. BIO-PCA00
Metal Cap For Indirect Peek Peek Hosting
Power Click Adaptor For Power Click
Attachment Cat No. BIO-PCIA0 Attachment
Cat No. BIO-PCMC0
Cat No. BIO-PCPH0
Silicone Transfer For Analog For BIO-PCAN0
Sealed Ring Power Click Power Click
Cat No. BIO-PCSSR Attachment Attachment
Cat No. BIO-PCTR0 Cat No.
32 | Bioline
Multi-Units
Multi-Unit BIO-M0101 BIO-M0102 BIO-M0103 BIO-M0104 BIO-M0105 BIO-M0106
Straight
Abutment 1.00 mm 2.00 mm 3.00 mm 4.00 mm 5.00 mm 6.00 mm
Cat No.
Height
Multi-Unit BIO-MPL01 Multi-Unit BIO-MTI01 Multi-Unit BIO-MTI0S
Plastic Titanuiem Short
castable Sleeve Titanuiem
Sleeve Cat No. Sleeve
Cat No. Cat No.
Healing Cap Transfer BIO-M0TR1 Analog BIO-M0AN1
For For For
Multi-Unit Multi-Unit Multi-Unit
Cat No. BIO-M0HC1 Cat No. Cat No.
Screw for Multi-Unit
BIO-M0SC1
Included with all
types of abutments
Bioline | 33
Angulated Multi-Unit
Angulated BIO-MU09 BIO-MU18 BIO-MU30
Multi-Unit
Abutment
Cat No.
Multi-Unit BIO-MPLD Multi-Unit BIO-MUTSDL Multi-Unit BIO-MUTSDH
Plastic Titanuiem Short
Castable Sleeve Titanuiem
Sleeve Cat No. Sleeve
Cat No. Cat No.
Healing Cap BIO-MUHC1 Close Open
For Transfer For Transfer For
Multi-Unit Multi-Unit Multi-Unit
Cat No. Cat No. BIO-MUTRIC Cat No. BIO-MUTRIO
Analog Screw for
For Multi-Unit
Multi-Unit
Cat No. Included with all types
of abutments
BIO-MUANAD Cat No. BIO-MOSC1
34 | Bioline
Esthetic Screw Abutment
Esthetic BIO-AA005 BIO-AA010 BIO-AA020
Screw 0.50 mm 1.00 mm 2.00 mm
Abutment
Cat No.
Height
Screw For BIO-AAS10 BIO-AAS11 BIO-AAS12
Esthetic 10.50 mm 11.50 mm 12.50 mm
Abutment
Cat No.
Height
Plastic Hexal Plastic Non BIO-AAPSL
Sleeve For Hexal Sleeve
Esthetic For Esthetic
Attachment Attachment
Cat No. BIO-AAPSL-H Cat No.
Bioline | 35
Instruments, Drills & surgical Kits
36 | Bioline
Instruments
Driver Hex BIO-X1207 BIO-X1210 BIO-X1215
1.25 mm 7.00 mm 10.00 mm 15.00 mm
Cat No.
Length BIO-X2407 BIO-X2410 BIO-X2415
7.00 mm 10.00 mm 15.00 mm
Driver, Hex
2.42 mm BIO-X2610 BIO-X2615
Front Ring 10.00 mm 15.00 mm
Cat No.
Length
Driver, Hex BIO-X2607
2.42 mm 7.00 mm
Cat No.
Length
Tools
Cat No. BIO-X1020
Description Rachet
Cat No. BIO-X1021
Description Tourque Rachet
Cat No. BIO-X1022
Description Surgical Screw Driv-
er Hex 2.42 mm
Cat No.
BIO-X1023
Description
Surgical Screw
Cat No. Long Driver
Description BIO-X1025
Depth Probe
Bioline | 37
Stopper Drills
Diameter BIO-STD2006 BIO-STD2008 BIO-STD2010 BIO-STD2011 BIO-STD2013 BIO-STD2016
2.0 mm
6.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
Cat No.
Length
Diameter BIO-STD2506 BIO-STD2508 BIO-STD2510 BIO-STD2511 BIO-STD2513 BIO-STD2516
2.5 mm
8.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
Cat No.
Length
Diameter BIO-STD2806 BIO-STD2808 BIO-STD2810 BIO-STD2811 BIO-STD2813 BIO-STD2816
2.8 mm
6.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
Cat No.
Length
Diameter BIO-STD3206 BIO-STD3208 BIO-STD3210 BIO-STD3211 BIO-STD3213 BIO-STD3216
3.2 mm
6.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
Cat No.
Length
Diameter BIO-STD3606 BIO-STD3608 BIO-STD3610 BIO-STD3611 BIO-STD3613 BIO-STD3616
3.65 mm
6.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
Cat No.
Length
Diameter BIO-STD4206 BIO-STD4208 BIO-STD4210 BIO-STD4211 BIO-STD4213 BIO-STD4216
4.2 mm
Cat No. 6.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
Length
Diameter
5.2 mm
Cat No. BIO-STD5206 BIO-STD5208 BIO-STD5210 BIO-STD5211 BIO-STD5213 BIO-STD5216
Length 6.00 mm 8.00 mm 10.00 mm 11.50 mm 13.00 mm 16.00 mm
38 | Bioline
InstrumentsINSTRUMENTS &AND DKITrSills
Drills
CountIerNsinSk TERxteUnsMionEMNarkTinSg A N DConKicaIl T S Trephine Standard / Short
CounterCsoiunnktersink Drills Marking MarkinEgxtension Extension
Cat No.Cat. Number BSIOIG--DD11003434 SIG-D1056BIO-D1056 SIG-D3410 BIO-D3410 SIG-D341B2 IO-D3412
DiameteDirameter ø33..880-4-.24m.2m0 mmø5.0-6.0mm5.00-6.00 mm
StandarSdtandard, 16mm SIG-D1220 SIG-D1225 SIG-D1228 SIG-D1232 SIG-D1236 SIG-D1242 SIG-D1252
16 mm Cat. Number
Cat No. DCioaBumnIetOetre-sriDnk12E2xt0ensiøoB2n.0IMOma-mrkDin1g225ø2.C5omBnmIicOal-D12ø22.88mmBIOTre-pDhø1i3n2.e23m2m BIOø-3DS.6t1a5nm2d3mar6d / ShBoørItO4.2-Dmm1242 ø5B.2IOmm-D1252
DiamCeoStuhenotrretr,s1in1k.52m.0m0 mm 2.50 mm 2M.a8rkminmg 3.2 mmExtensio3n.65 mm 4.20 mm 5.20 mm
Short Cat. NuCmatb. eNrumbeSIrG-D1034 SIG-D1SI4G2-0D1056 SIG-D1428 SIG-D34S1IG0-D1432 SSIIGG--DD1341326 SIG-D1442 SIG-D1452
11.5 mmDiameDteirameteør3.8-4.2mm ø2.0øm5.m0-6.0mm ø2.8mm ø3.2mm ø3.65mm ø4.2mm ø5.2mm
Cat NSotTarn.edpahrdin, e16BmImO-D1420 BIO-D1428 BIO-D1432 BIO-D1436 BIO-D1442 BIO-D1452
DiameterCaCt.aNtu. Nmubmerb2e.r00 SmIGm-D1220SIG-SDIG22-0D.28102025mmSIG-D1228S3IG.-2DS0I2G0-m3D01m232 SIG-D132.36S6I5G-mDS2mIG04-D01242 S4IG.2-D012m5S2IGm-D2050 5.20 mm
DiaDmiaemteer ter ø2.0møm2.0mmø-32..50mmmm ø2.8møm3.0mm-ø43.0.2mmmm ø3.65øm4m.0mm-5ø.40.2mmmm ø5.2øm5m.0mm-6.0mm
TrephineShCoornt,i1c1a.l5, m16mmm SIG-D3031
Cat No.CaCt.aNtu. NmubmeBrbIeOr -D2S0IG2-DS01IG42-D03018 SIG-DB1IS4OI2G8--DD3200230S0IG-D143S2IG-D30S2BI5GI-OD1-4D362S0IG4-0D3S0IG2-7D1442 SBIGIO-DS-3IGD0-2D281045520
DiameterDiaDmiaemteer te2r.00-3.ø020ø.01mm.8m-m2.4mm ø2.38mø.02m.00--34.2.0m0mmø3.m2møm2.5-3.7m4øm.30.605-m5m.ø020.7-m4.0mmø4m.2mm ø52..70-40.ø5-56m.2.m0m0m mmø3.1-5.5mm
Trephine SIG-D2020 SIG-D2030 SIG-D2040 SIG-D2050
ConicalGaCnagt. ,N1um6mbemr
1C6amt mNo. DCiaaDtm.iaNemtueBmer tIbeOrer-D301øS28øI.G02m-.D0mm3-6m32.00BmImOSøIG-2D-.D53m306m2250ø3.0SmøIG2m-.D8-B4m3.0I6mOm28m-D3SøI0G32-.D25m36øm342.0mmSøBI3-G5.I-6.O0D5m3m-m6Dm33602S7øIG4-.D0øm356.m04m0BmI-6SOø.I0G-4mD-.D3mm3360m4238
DiamCeotneicral, 16mm1.8-2.4 mm 2.0-3.2 mm 2.5-3.7 mm 2.7-4.0 mm SIG-D3652
ø5.2BmImO-D3031
2.7-4.5 mm 3.1-5.5 mm
Gang Cat. Number SIG-D3018 SIG-D3020 SIG-D3025 CSoIGlo-Dr3C02o7de SIG-D3028 SIG-D3031
Diameter ø1.8-2.4mm ø2.0-3.2mm ø2.5-3.7mm ø3.1-5.5mm
ø2.7-4.0mm ø2.7-4.5mm
16 mm BIO-D3643 BIO-D3652
Cat No.Gang, 16mm
Cat. NumBbIOer -D36S2IG0-D36B20IOS-IDG-3D3662255 SIGB-DIO3L6a-s2eD8r M3ar6SkI2G-8D363B2 IOSI-GD-D33663362 SIGB-DIO36-4D0 3S6IG3-6D364B3 IOSIG-D-D33665420
DiameterDiameter2.00 møm2.0mm 2.ø520.5mmmm 2.8 mmø2.8mComlor Codeø3.2mm 3ø3..265mmmm ø4.0m3m.65 mø4m.3mm 4ø.05.20mmmm
4.30 mm 5.20 mm
Depth Groove 16mm Color Code ø3.65 ø4.2 ø4.5 ø4.8 ø5.2 ø5.5
13mm ø2.0 ø2.8 ø3.2
11.5mm
10mm
8mm
6mm
Laser Mark
Color Code ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø4.5 ø4.8 ø5.2 ø5.5
Depth Groove 16mm
13mm
11.5mm
10mm
8mm
6mm
Bioline | 39
Surgical Kits
Professional
Surgical Kit
Cat No. BIO-PRO-KIT
Small Starter Kit
Surgical Kit Cat No. BIO-STR-KIT
Cat No. BIO-BASIC-KIT
40 | Bioline
Notes
Bioline | 41
WWW.BIOLINE-IMPLANTS.DE The art of simplicity
BIOLINE DENTAL IMPLANTS
PLATZ DER EINHEIT 1, FRANKFURT, HESSEN
60327 GERMANY
OFFICE: +49 69 97 503 415
CUSTOMER SUPPORT:
INFO@BIOLINE-IMPLANTS.DE
WWW.BIOLINE-IMPLANTS.DE
CE partner4u B.V.
Edoomlan 13,3951 DB Maam, Netherlands
www.cepartner4u.eu