POWER PROTECTION

1.4.PMU SERIES 60-200KVA PMU SERIES 60-200kva Modular Ups 3:3 Phase Pf : 0.9

Overview: • Because the input power factor is up to 0.999,
PMU series UPS is 3-phase On-line UPS, in which the energy efciency can be improved a lots, the
the advanced 3-level inverter & latest DSP- grid load becomes lower, and the cost of
controlled technology are employed. Modular electricity distribution can be reduced.
N+X parallel redundancy design ensures the • Intelligent battery management: it is
normal operation all the time even though one of automatically converting boost or oat charge,
power module is in fault. And hot-swappable temperate compensate to avoid over or less
feature ensure UPS normal operations to the load charge; adjusted the cut off voltage of discharge
without interruption during maintenance and according to load capacity, greatly extend life of
replacement with low MTTR (Mean Time To the battery pack. With intelligent fan speed
Repair). control, the fan speed is depended on the load
capacity to extend the life of fan.
Feature: • Under ECO energy-saving mode, the efciency
• By employing TI’s DSP control, the processing of UPS system can be more than 99%, suitable for
speed and fault protection become much better. the area of good AC quality.
• By using advanced 3-level inverter technology, • And it can quickly switch back to inverter mode
it has good output wave form and high over-all within 5ms.
efciency. • Manual bypass design ensures uninterrupted
• With cold-start function, the UPS can be started operations during maintenance and the system
up without AC input. becomes more reliable

www.poweronenertech.com 07

Technical Specifications

MODEL PMU 339-60K PMU 339-100K PMU 339-120K PMU 339-200K PMU 339-120K-277V PMU 339-200K-277V
Rated Capacity 60kVA/54kW 100kVA/90kW
Power Module Capacity 120kVA/108kW 200kVA/180kW 120kVA/120kW 200kVA/200kW
INPUT 10kVA/9kW
Nominal voltage 20kVA/18kW 20kVA/20kW
Voltage range
Frequency range 120/208V(3P4W + G) 220/380V(3P4W + G) 277/480V(3P4W + G)
Bypass Synchronization ±15%(±10% / ±20% selectable) ±25% ( ±20% / ±15% selectable) ±15%(±10% / ±20% selectable)
50/60Hz ±10%(±5% selectable)
50/60Hz ±5%(±10% selectable)

Bypass voltage range +15% ( +10% / +20% selectable)
-20% (-15% / -30% selectable)

Power Factor ≥ 0.99

Total Harmonic Distortion (THDi) Linear load(full load) ≤3% Non-linear load(full load) ≤5%
OUTPUT

Voltage 120/208V(3P4W+G or 3P3W+G) 220/380V(3P4W+G or 3P3W+G) 277/480V(3P4W+G or 3P3W+G)

Voltage Regulation ±1%(Static)

Frequency Synchronized (AC mode);50/60Hz ± 0.2%(Battery mode)
Phase Difference Balanced load: ≤2 Unbalanced load: ≤5
Total Harmonic Distortion (THDi) Linear load: ≤3% ; Non-linear load: ≤6%
Bypass Inverter Transfer Time
Synchronized:0ms ; Asynchronous<20ms

Efciency AC mode ≥92.5%;Battery mode ≥95% AC mode ≥94%;Battery mode ≥97% AC mode ≥95%;Battery mode ≥97%

Overload Capability 125% : 10 minutes
Current Sharing <5%
DC Component
Unbalance Load Capability ≤100mV
BATTERY 100% unbalanced load
Nominal Voltage
Charging Current ±192Vdc ±360Vdc ±408Vdc

Max. 30A Max. 50A Max. 30A Max. 50A Max. 30A Max. 50A

Protection of Battery Yes
Deep Discharge

Battery Start Yes
ENVIRONMENTAL
Operating temperature 0°C ~ 40°C(32~104°F)
0 ~ 95% (non condensing)
Relative Humidity
63 dBA
Audible Noise (At 1M) IP20
Protection(IP degree)
DISPLAY 7 inch touch-screen LCD, Multi-language supported
LCD UPS working status
LED
INTERFACE Input dry contact, output dry contact, RS232/RS485, SNMP(optional)
Standard
PHYSICAL OF BATTERY BANK 600X900X2000 600X900X1400 600X900X2000 600X900X1400 600X900X2000
Unit Dimensions DXWXH (mm) 600X900X1400

UPS System 327kg(N.W.), 500kg(N.W.), 345kg(N.W.), 538kg(N.W.), 345kg(N.W.), 538kg(N.W.),
362kg(G.W.) 540kg(G.W.) 380kg(G.W.) 570kg(G.W.) 380kg(G.W.) 570kg(G.W.)
Weight
Power Module 22.1kg(N.W.),24.3kg(G.W.) 25.1kg(N.W.), 27.3kg(G.W.)

www.poweronenertech.com 08

POWER PROTECTION

1.5.POWERGUARD MPS 300 Powerguard MPS 330 Series N+X Modular UPS series
5-210KVA (3 Ph in/3Ph out)

• Small size, light weight.

• Easy maintenance, free replacement of the
module.

• System controller for communication and diagnosis.

• Adopt centralized Static Switch module.

• Capacity : the power module has three modes of
5KVA, 10KVA and 15KVA, user can choose the
power according to their need.

• Module: MPS 330 series is a modular parallel
redundant UPS system, The system consist of three
module: Switch module, Display & Communication
Module, and Power Module (can parallel from 1 to

10 pcs)

• Multi-setting : According to input power condition,
user can set up the UPS conguration with 4 kinds of
working model (3 phase in & 3phase out, 3 phase in
& 1phase out, single phase in & out, single phase in
& 3phase out)

Overview: • Energy - saving: Compared with traditional UPS,
• N+X MODULAR DESIGN, FULL UPGRADED which efciency less than 90%, about 10% is wasted.
PROTECTION MPS330 inverter efciency is above 96%. It is
designed for lower heat emission, less energy waste.
• Modular UPS has the independent power and
control sections, That's each module is an independent • Green and clean power: The level of harmonic pollution
UPS. MPS330 is modular system adopts the of MPS330 is very low, with input current THD<3%,
centralized multiple parallel. N+X format. It's simple Input PF above 0.999, This reduces more pollution
for system expansion with little fault points. It provides
load with N+1 to N+X levels of protection. The to main and power loss than equivalent traditional
maximum capacity can be expanded to 210kva. The UPS.
reliability and exible of the system it is incomparable
with traditional UPS. • Management software : MPS330 provides a real
time monitoring and access to data on current
operational status, control features, conguration
information, and more.

• APPLICATION • Easy Expansion : With the upgrade of customer's
IDC (Internet Data Center), computing center, ISP load requirement, the original designed UPS may
(Internet Service Provider), Telecom, Finance bank and not be able to meet the demand. According to the
securities, Tax, hospital system, industrial automation, traditional UPS system, we must replace a new and
precision equipment, etc.. higher capacity UPS system for customers. But for
modular UPS there is no need to replace the whole
Feature: UPS, but only adding the required number of
• Multi-setting, according to input power condition modules for expansion. MPS330 modular UPS can
user can set up the UPS conguration with 1/1, 1/3, be expanded on line from 5kva to 210kva. The
3/1 or 3/3 four kings of working model. advantage of module is reducing customer's costs for
initial equipment purchase and future expansion.
• Module structure, be compose from 1 to 10 modules. Satisfy customer's investment requirement by
providing exible number of modules for business
• Redundant and scalable system,it can be upgraded growth.
according to your requirement.
• Hot Swappable : Hot Swappable modules can to be
• N + X redundancy, reliable performance. added or removed on line. There is no need for senior
technical personnel to perform the job. It is safe and
• Share battery pack. convenient. Maintenance and repair is easy as there is
no need to switch to bypass. Communication modules
• Green and clean power, Input THDI<5% and power modules are both hot swappable. On-line
expansion or redundancy enhancement can be
• Input PF>0.99 achieved easily without modication.

www.poweronenertech.com 09

Technical Specifications

MODEL MPS330 5-210KVA
Unit module Capacity 5KVA 10KVA 15KVA
System Capacity
Rating Frequency 5-210KVA
INPUT 50Hz/60Hz
Voltage Range
Phase 380/400/415V±20%
Frequency Range Three phase 4 wire+G/ Single phase2 wire+G
Power Factor
Total Harmonic Distortion 45Hz-55Hz
Slow Start ≥0.99
OUTPUT <3%
Voltage Range >60sec

Frequency Precision 220V (single phase) 380/400/415V (three phase)
Main power within 50 ±2%, output tracking mains frequency, when phase shift< 3°;

main power overrun or battery supply. the output is 50Hz±0.2%

Power Factor 0.8
Waveform Distortion Linear loads≤3%, Nonlinear load≤5%
Crest Factor
Efciency 3:1
Average Current Precision ≥95% (AC-AC) (100% load) ≥98% (under batt...)
Transfer Time
≤5%
Transient Dynamic 0ms
Response Range
Output voltage≤2% (overload change between 10%~100% or change between 100%~10%)
Load Capacity
DC 100% imbalance load
Input Voltage
Input Range ±384V
345~440V
Backward relative broad band
noise current against DC input <10%

Backward relative prophometric weighted <1%
noise current against DC input

INDICATION English UPS status and operation of guided input voltage, output voltage, current, frequency,
LCD battery voltage and charge and discharge current values, fault indication, warning

WORKING ENVIRONMENT 0°C~40°C
Temperature 0~95% (Non-condensing)
Humidity
Storage Temperature -25° C~ 55° C
Altitude ≤1500m
Noise (within 1 meter) <50dB
PHYSICAL FEATURE
Dimension (WXDXH)mm 600x800x2000
STANDARD
Conrm to GB/IEC regulation
EMC GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5
SAFETY
GB4943
www.poweronenertech.com
10

POWER PROTECTION 2. OUTDOOR ONLINE UPS

2.1.PHO 118E 1-10KTXL PHO118E 1-10KTXL Integrated Outdoor Online
Ups 1-10kva

Overview:
Model: 1-10KVA
Nominal Voltage: 220/230/240VAC
Nominal Frequency: 50/60Hz
Output Power Factor: 0.8

Feature: •Optional Accessories Like Heat
• Double Conversion Pure Sine wave Online Exchanger/Air conditioner
• Extendable Battery Pack for long backup
Design • Lightning Arrester Built-in
• High Temperature Resistant Design •Multiple communication accessories
•Sealing Level For IP55 with Dust proof Water optional
proof Features • LCD display optional.
• Wide range of Input Voltage and Frequency • IP level increasable
Window

www.poweronenertech.com 11

Technical Specifications

MODEL PHO118E 1KTXL PHO118E 2KTXL PHO118E 3KTXL PHO118E 6KTXL PHO118E 10KTXL
Capacity(VA/Watts) 0.8KVA 1.6KVA 2.4KVA 4.8KVA 8KVA
Nominal voltage
220/230/240VAC

Nominal frequency 50Hz/60Hz

INPUT 115~295VAC (±3VAC) 176~297VAC (±3VAC)
Voltage range
Frequency range 50HZ: (46~54HZ) ; 60HZ: (56HZ~64HZ)
Soft start 0~100% 5sec
Power factor
OUTPUT 0.98

Voltage precision 220/230/240X ( 1± 2%)VAC
Frequency precision 50/60HZ:0.05Hz

Power factor Standard 0.8
Wave distortion Linear load <3% Non-linear load <6%
Overload capability Overload (110% ~ 150%) for 30 seconds, then automatically transfer to bypass.
Crest factor When load is normal, it can automatically transfer to normal mode.
Transfer time
BATTERY 3:1
0ms (AC to DC )

DC Supply Voltage 36VDC 96VDC 96VDC 240VDC 240VDC
Charge Current 4A/8A (optional) 4A/8A (optional) 4A/8A (optional) 4.2A 4.2A

Internal Battery Capacity (38/65/80/100AH) optional
PANEL DISPLAY

LED Load level/Battery level, Battery indicator, Utility power, Inverter, Bypass, Overload, Fault

COMMUNICATIONS

Communicate interface RS232 SNMP card (optional)

WORK ENVIRONMENT

Temperature -40°C ~ 55°C

Humidity 0 ~ 95% (non condensing)

Storage Temperature - 25°C ~ + 55°C

Elevation < 1500m

PHYSICAL CHARACTERISTIC

Net weight (kg) 85 125 125 150 155

Dimension D X W X H (mm) 613X640X954 650X753X1227 650X753X1227 940X940X1770 940X940X1770
STANDARDS

Safety GB 4943

EMC GB7260.2/IEC62040-2 -GB/17626.2~5/lEC61000-4-2~5

www.poweronenertech.com 12

POWER PROTECTION 3. LINE INTERACTIVE UPS

3.1. PHP 110E SERIES Protector HP110E series Line – interactive UPS
600 -2000 VA

POWERON

POWERON

Overview: Feature:
Model : 600-2000 VA • Microprocessor control guarantees high
Nominal Voltage: 220/230/240VAC reliability
Nominal frequency: 50/60Hz • Advance line-interactive design
Output Power factors: 0.6 • Intelligent voltage regulation technique
Models available : 600VA , 800VA , 1000VA , • Intelligent charging technique
1400VA & 2000VA • User-replacable battery design
• Complete soft ware monitoring system

www.poweronenertech.com 13

Technical Specifications

MODEL HP 110E-600VA HP 110E-800VA HP 110E-1000VA HP 110E-1400VA HP 110E-2000VA
Capacity(VA/Watts) 600VA/360W 800VA/480W 1000VA/600W 1400VA/840W 2000VA/1200W
Nominal voltage 220/230VAC

Operating voltage range 50/60Hz
INPUT

Voltage Range 165VAC-275VAC(± 5VAC)
Frequency range 40/70HZ
OUTPUT

Voltage Regulation 220/230/240VAC ± 10%
Frequency Regulation Battery model : 50/60Hz ± 0.1Hz AC model : Auto sense

Wave Form Modied sine wave
Transfer Time <10ms (Typical 5ms)
BATTERY

Battery Type and Number 12V/7Ah X 1pcs 12V/7Ah X 1pcs 12V/7Ah X 2pcs 12V/7Ah X 2pcs 12V/7Ah X 2pcs
LCD DISPLAY

AC Mode Green lighting The 1st green LED lighting
Green lighting The 2nd to 5st green LEDs gradually lighting indicating load level

Battery Mode Green ashing The 1st green LED ashing
Green ashing The 2nd to 5st green LEDs gradually lighting indicating battery capacity

Fault The red LED lighting

COMMUNICATION

Communication port RS232 port, USB port (Optional)

OPERATING ENVIRONMENTAL

Operating temperature 0°C ~ 40°C

Humidity range 5% ~ 95% (<40°C, Non-condensing)
Storage Temperature -25°C ~ 55°C
Elevation < 1500m

Noise (within 1 meter) < 45dB
PHYSICAL CHARACTERISTIC

Dimension D X W X H (mm) 330 X 100 X 140mm 405 X 205 X 145mm

Net weight (kg) N.W. 6 6.5 9.6 9.7 9.8
G.W. 8 8.5 11.6 11.7 11.8

STANDARDS

Safety GB4943

EMC GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5

www.poweronenertech.com 14

POWER PROTECTION

3.2. PROTECTOR PL 116A Protector HP110E series Line – interactive UPS
650T-1000T 600 -2000 VA

Feature: optimizes reliability
• Double boost and buck AVR for
• Frequency auto adaptive
• Low transfer time (<5ms) voltage stabilization
• Echo friendly and user friendly • Perfect protection for overload ,
• Auto restart while AC is recovering
• Line mode, Battery mode and fault short circuit , over-voltage ,low-
voltage and over-heating etc
alarm • Compact size and ergonomic
• Off mode charging and cold start design: it can be placed on a desk
top or other convenient location
function
• Excellent microprocessor control

www.poweronenertech.com 15

Technical Specifications PL116A 650T PL116A 1000T
650VA/360W 1000VA/600W
Model 220/230Vac 110/120Vac or 220/230Vac
Capacity 140-300Vac 81-145VAC/140-300Vac
Input Voltage
Input Voltage Range 50Hz/60Hz (Auto-sensing)
Input Frequency Range
Output Voltage 220/230Vac 110/120Vac or 220/230Vac
AC Voltage Regulation
Frequency Range ±10% (Bat Mode)
Active Power
Transfer time 50Hz ± 1Hz (Bat Mode)
Waveform (Bat Mode)
Battery 360W 600W
Battery Type & Number
Floating Charging Voltage Typical 2--6ms
Charging ability
Line mode Simulated Sine wave
Battery mode
Fault Lead-acid battery
Battery mode
Low battery 12V/7Ah*1 12V/9Ah*1
Overload
Battery Replacement Alarm 13.7VDC
Fault 4-6 hours recover to 90% capacity
Dimension D*W*H(mm)
Net Weight (kg) Green lighting
Humidity Yellow ashing
Noisy Level
www.poweronenertech.com Red lighting
Sounding every 10 seconds

Sounding every second

Sounding every 0.5 seconds
Sounding every 2 seconds

Continuously sounding
279*101*142
4.9

0-90% Relative Humidity 0-40 °C (Non-condensing)
Less than 40dB

16

POWER PROTECTION

3.3.NEW POWER PROTECTOR PLSH 500VA,600VA , 800VA , 1200VA ,1500VA
SERIES PLSH 500-1500VA

Overview: Feature:
Power protector series PLSH UPS is a “Lite” • Compact size
UPS to protect your power issue on personal • Excellent microprocessor control
computers. It provides comprehensive guarantees
protection in a small and economic package.
Not only offering greater comprehensive high reliability
power protection against surges and spikes, • Boost and buck AVR for voltage stabilization
it also provides pure voltage with built-in AVR • Auto restart while AC is recovering
stabilizer. The UPS will continue providing • Simulated sine wave
clean and stable power to connected • Off-mode charging
equipment while its embedded • Cold start function
microprocessor controller guarantees high • Generator compatible (option)
reliability, perfect for any home or small ofce
application.

www.poweronenertech.com 17

Technical Specifications

MODEL PLSH 500 PLSH 600 PLSH 800 PLSH 1200 PLSH 1500
Capacity 500VA/300W 600VA/360W 800VA/480W 1200VA/720W 1500VA/900W
INPUT
12 V/9 Ah x 2
Voltage 110/120 VAC or 220/230/240 VAC
Voltage Range 81-150 Vac / 145-290 Vac
Frequency range 60/50 Hz (auto sensing)

OUTPUT

Voltage 110/120 VAC or 220/230/240 VAC± 10%
Waveform (Batt.Mode) 50 Hz or 60 Hz ± 1 Hz
Transfer Time Typical 2-8 ms
AC Voltage Regulation Simulated Sine Wave

BATTERY

Battery Type and Number 12 V/4.5 Ah x 1 12 V/7 Ah x 1 12 V/9 Ah x 1 12 V/7 Ah x 2
Typical Recharge Time 4 hours up to 90% capacity
PROTECTION
Overload, discharge, and overcharge protection
Full Protection

INDICATORS

AC Mode Green lighting
Battery Mode Green Flashing

ALARM

Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload
Fault Sounding every 0.5 second
Continuously sounding

PHYSICAL

Dimension 279 x101 x142 350 x 146 x 160 397 x 146 x 205
D X W X H (mm)

Net weight (kg) 3.55 4.2 4.9 8.0 11.1
ENVIRONMENT
0-90 % RH @ 0- 40°C (non-condensing) 18
Humidity Less than 40dB

Noise Level

www.poweronenertech.com

POWER PROTECTION PLS 400~2000VA Work: Line Interactive
Applications: PC, workstation, SOHO equipment, etc.
3.4.POWER PROTECTOR
SERIES PLSK 400-2000VA

Feature: • Built-in Self-diagnostic function
• Cold start function • Modem/LAN internet protection
• Auto-restart function • Smart RS232/USB interface for power
• AVR boost and buck
• Fastest charging capacity management
• Auto charging at off mode • Compatible with generator set (optional)
• LCD or LED panel for option
19
www.poweronenertech.com

Technical Specifications

MODEL PLSK 400 PLSK 600 PLSK 800MPSP3L3S0K 150-20100KVPALSK 1200 PLSK 1500 PLSK 2000
Capacity(VA/Watts) 400 / 240 600 / 360 800/ 480 1000 / 600 1200 / 720 1500 / 900 2000 / 1200

INPUT

Nominal input voltage 110/120 Vac or 220/230/240 Vac
81 ~145 Vac / 162 ~ 290 Vac
Operating voltage range 50/60 Hz (± 10%)

Operating frequency range

OUTPUT

Output voltage range Simulated sine wave at nominal voltage ± 10%
(Batt. Mode)

Frequency range 50 or 60Hz ±1Hz
(Batt. Mode) Typical 2~6 ms, 10ms max.

Transfer Time 12 V/4.5Ah X 1 12 V/7Ah X 1 12 V/9Ah X 1 12V/7Ah X 2 12 V/7Ah X 2 12 V/9Ah X 2 12 V/9Ah X 2
BTyApTicTaElRrYecharge time 6~8 hours (to 90% of full capacity)
Battery type & number
Typical recharge time
SYSTEM FEATURES

AC Mode (Green LED lighting) The 5th Green LED lighting
(The 1st to 4th green LED lighting to indicate load level)

LED1 (green): >100% load level
LED2 (green): >75% load level
LED3 (green): >50% load level
LED4 (green): >25% load level

Indicators

Battery Mode (Amber LED ashing) The 5st green blinking
(The 1st to 4th green LED lighting to indicate battery capacity)

LED1 (green): battery voltage > 25V
LED2 (green): battery voltage > 23V
LED3 (green): battery voltage > 22V
LED4 (green): battery voltage > 21V

Protection Fault (Red LED lighting)
Alarm
Overload and overcharge protection

Battery Mode: Sounding every 10 seconds
Low battery: Sounding every second
Overload: Sounding every 0.5 second

Battery replacement alarm: Sounding every 2 seconds
Fault: Continuously sounding

Communication interface USB/RS-232 (optional),Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC

NO3.eP5tE5wRAeiTgIhNtG(kEgN) VIRONMENTAL 0°C ~ 40°C
Operating temperature

Humidity range 0% ~ 95% (Non-condensing)

Noise level < 40dB (1 meter from surface)

PHYSICAL CHARACTERISTIC

Dimension D X W X H (mm) 298 X 101 X142 338 X 149.3 X 162 380 X 158 X198

Net weight (kg) 3.55 4.25 4.9 7.8 8 11.1 11.5
STANDARDS

Safety lEC/EN62040-1; lEC/EN60950-1

EMC IEC/EN62040-2; lEC61000-4-2; IEC61000-4-3; lEC61000-4-4; lEC61000-4-5; IEC61000-4-6; IEC61000-4-8

www.poweronenertech.com 20

POWER PROTECTION

3.5.Pure Sine Wave PLPSH Pure Sine Wave Line Interactive UPS PLPSH 1-3KVA
1-5KVA Long Backup WITH LONG BACKUP -PLPSH 1-5KL

APPLICATION
PC, office, communication switching system,
server, Ian equipment, ATM system etc.

Feature: • Automatically transfer to battery mode
• Intelligent CPU control when over-voltage,under»voltage
• Wide input voltage
• LCD/LED display • Overload, short circuit protection
• AVR function • Can connect to external battery, extending
• Mute function
• Pure sine wave output backup time
• Compatible with generator • Large charging current for big capacity

battery

www.poweronenertech.com 21

Technical Specifications

MODEL PLPSH1K PLPSH1.5K PLPSH2K PLPSH3K PLPSH1KL PLPSH1.5KL PLPSHP2HKL119PCL-P3KSHT3SKL PLPSH5KL
Rated Capacity 1000VA 1500VA 2000VA 3000VA 1000VA 1500VA 2000VA 3000VA 5000VA
Rated Power 700W 1050W 1400W 2100W 700W 1050W 1400W 2100W 3500W

DISPLAY LCD / LED Optional
Indicators Panel
AC MODE 145-275Vac or 85-150Vac
Input voltage 48-54Hz, or 56-64 Hz, following AC frequency
Input frequency
Output voltage 200-240Vac or 100-132Vac
Over-current protection Breaker
INVERTER MODE
Output voltage 220/230Vac ± 5% or 110/120/127Vac ± 5%
Output frequency 50/60 ± 0.5Hz
Power factor 0.7
Output wave form Pure sine wave
Transfer Time
Overload capacity Typical 2-6ms,10ms max
Over-current protection 110% shutdown within 60sec/120% shut down within 5 sec
BATTERY
Battery model System shut down automatically within 20ms
DC voltage
Sealed maintenance-free lead-acid battery

DC 24V DC 48V DC 24V DC 48V

Standard conguration 12/7AHX2 12/9AHX2 12/7AHX4 12/9AHX4 External battery
10A(non-settable)
Charging current 3A(non-settable) Depends on the battery connected

Charging period 6-8 hours recover to 90% capacity

PHYSICAL

Net weight (kg) 23.8 25.6 30.2 34.5 19.8 21.4 26.6 32.7 41.5
UPS size(mm) 405*145*220 455*195*330
Carton size(mm) 495*238*343 525*335*485 405*145*220 455*195*330
ENVIRONMENT
Environment 495*238*343 525*335*485
Noise Level
Altitude Temperature 0°C - 40°C, humidity 20%-90%
MANAGEMENT ≤ 40dB(1m)

Altitude exceeds 1000m, full power can not reach

Communication slot Standard with RS232, optional USB

www.poweronenertech.com 22

POWER PROTECTION

3.6.PURE SINE WAVE PLPSK PLPSK – Pure Sine Wave Series 1000VA, 1500VA, 2000VA
1000-2000VA

Overview: Feature:
This ups is specially designed for personal • LCD display
computer with multi functions. Its light weight • DC Start Function.
, compact design perfect ts to the limited • Compact size, Light Weight.
working environment. The line of ups is • Auto restart while AC recovery.
equipped with boost and buck avr to stabilize • Provides AC Overload protection.
input voltage range .its also built in with dc • Equipped with Boost and Buck AVR
start function .this function enables ups to be • Microprocessor control guarantees high
started up with out ac power supplied ,
although its a small ups reliability

www.poweronenertech.com 23

Technical Specifications

MODEL PLPSK 1000 PLPSK 1500 PLPSK 2000
Capacity 1000 VA / 700 W 1500 VA / 1050 W 2000 VA / 1400W
Transformer Size
INPUT EI 114*40 EI 114*60 EI 114*60
Voltage
Voltage Range 12 V / 7Ah x 2 110/120 VAC or 220/230/240 VAC 12 V / 9 Ah x 2
Frequency Range 81-145 VAC /162-290 VAC
OUTPUT 50/60 Hz (Auto sensing)

AC Voltage Regulation ±10%
(Batt.Mode) 50 Hz or 60 Hz ± 1 Hz
Frequency Range (Batt. Mode)
Waveform (Batt. Mode) Pure Sinewave
Transfer Time Typical 2-6 ms, 10ms max.
BATTERY
Battery Type & Number 12 V / 9 Ah x 2
Typical Recharge Time
PROTECTION Overload, discharge, and overcharge protection
Full Protection
INDICATORS AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage,
Overload, Fault, and Low Battery
LCD Display
353x 149.3 x 162 Sounding every 10 seconds
ALARM Sounding every second
Battery Mode
Low Battery Sounding every 0.5 second
Overload Sounding every 2 seconds
Battery Replacement Alarm
Fault Continuously sounding
PHYSICAL
Dimension, D x W x H (mm) 380 x 158 x198

Rear Panel

Net Weight (kgs) 8.7 10.7 11.5
ENVIRONMENT
Noise Level Less than 45dB Less than 55dB
MANAGEMENT
USB & RS-232 Port Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC
(1) AVR Boost and Buck
Other Features (2) Overload, discharge, and overcharge protection
(3) Cold Start Function
www.poweronenertech.com (4) Smart USB/ RS232 Interface for Power Management
(5) Built-in Self-diagnostic Function
(6) Modem/LAN Internet Protection
(7) LCD panel
(8) Fastest Charging Capacity
(9) Auto Charging at Off Mode

(10) Auto-restart Function

24

POWER PROTECTION 4. LF ONLINE UPS - 3:3

4.1.GP 332C 10-120KVA Powerguard GP332C Series Low Frequency Online UPS
10-120 kVA (3Ph in / 3Ph out)

Overview: units per backup (N+1) or power parallel. A
NominalInputvoltage:380/400/415VAC parallel between models with different power
Output Power factor : 0.8 levels is possible.
Parallel : maximum : 8 PCS UPS
Battery can be shared in parallel Hot System Expansion (HSE) : HSE allows
Absolute Protection the insertion of a new UPS within an existing
GP332C is an on-line double conversion UPS system, without the need to switch off the
(VFIISS 111 in accordance with IEC EN UPSs which are already operating or switch
62040-3) with a transformer isolated them to bypass mode.
inverter. GP332C has a compact foot print This guarantees maximum load protection,
and high quality output to provide the even during maintenance and enlargement.
ultimate power protection for "mission Maximum levels of availability also in the
critical" applications : data processing, event of an interruption to the parallel bus
telecommunications, industrial processes, cable: the system is "FAULT TOLERANT". It is
security and electro-medical systems. not affected by faults with the connection
The GP332C range includes three-phase cables and continues to power the load
output models from 10 to 120kVA, Models without a continuity solution, signaling the
from 10-120kVA are available with a 6 or 12 anomaly with an alarm.
pulse rectier.
From 100kVA to 120kVA GP332C is High Efficiency Parallel System (HEPS) : This
available in a HIP (High Input Performance) is the system which optimises the efciency of
format with an IGBT-based rectier offering the system in parallel, according to the power
even lower input harmonic distortion (THDi) required by the load at that moment.
and unity input power factor. The N+1 redundancy is nevertheless
guaranteed, but each UPS operating in
Maximum Levels Of Reliability And parallel operates at the best possible load
Availability level in order to achieve the highest overall
Distributed or centralised parallel up to 8 efciency.

www.poweronenertech.com 25

Technical Specifications

MODEL GP332C 10KVA GP332C 15KVA GP332C 20KVA GP332C 30KVA GP332C 40KVA GP332C 60KVA GP332C 80KVA GP332C 100KVA GP332C 120KVA

POWER (kVA) 10 15 20 30 40 60 80 100 120

INPUT 380-400-415 Vac three-phase
Nominal Voltage tolerance

Frequency 400 V + 20%/- 25%

Soft start 45 ÷ 65 Hz
Permitted frequency tolerance 0÷100% in 30" (selectable)

Standard features ±2% (selectable from± 1% to±5% from the front panel)

BATTERIES Back Feed protection; separable bypass line
Type lead, ooded and VRLA AGM / GB; NiCd

AC ripple <1%
Temperature compensation -0.5Vx °C
Typical charging current 0.2xC10

OUTPUT 10 15 20 30 40 60 80 100 120
Rated power (kVA)

Active power (kw) 8 12 16 24 32 48 64 80 96

Number of phases 3+N

Nominal voltage ±1%
Static stability 380-400-415 Vac three-phase

Dynamic stability ±5% in 10 ms

Voltage distortion <1% with linear load / < 3% with no-linear load

Crest factor (lpeak/Irms) 3:1

Frequency stability on battery mode 0.05%

Frequency 50 or 60 Hz (selectable)

Overload 110% for 60; 125% for 10; 150% for 1

ENVIRONMENTAL 210* 220* 230 280 330 450 600 640 650
Weight (kg) without batteries 1400x800x740
Dimensions (hwd) (mm) 1400x555x740
Remote signalling
Voltage-free contacts

Remote commands EPO and bypass

Communication double RS232+ remote contacts + 2 communication interface slots
Operating Temperature 0 °C/+40 °C

Relative humidity <95% non condensing

Colour Light grey RA 7035

Noise 54 60 62 63 ÷ 68 dBA at 1m
Protection rating IP20
Efciency Smart Mode
Up to 98%

Compliance European Directives : I V 2006/95/CE; EMC 2004/108/ECl; Safety IEC 62040-1; EMC IEC EN 62040-2 C2

Classication according ot IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

www.poweronenertech.com 26

POWER PROTECTION

4.2.GP 335C 120-400KVA Powerguard GP335C Series Low Frequency Online UPS
120-800 KVA (3 Ph in/3 Ph out)

performance.
• Extra strong capability to withstand output overload and
short circuit, ensuring the system stability and system safety
under extreme conditions.
• Layered independently-sealed ventilation channel and
redundant fan, circuit boards with protective paints and a
dust lter embedded make it highly efcient to dissipate heat
and protect the product effectively under severe
environment.

Model : 120-200KVA Excellent Electrical Performance
Nominal voltage : 380/400/415VAC Online double transform structure, double DSP control
Nominal frequency: 50/60Hz technology.
Output Power factor : 0.9 • GP335C series UPS Using real online double transform
Parallel : maximum 6PCS UPS structure. This architecture is currently the best to solve the
Efciency Rate of Machine:>94% (>98% in ECO Mode) power structure. The frame work can almost completely
solve all the power problems, such as power utility high and
Overview: low voltage, voltage instantaneous fall, reduce oscillation,
Efficient • Energy -saving • Environmental -protection • high-voltage pulsed, voltage uctuation, surge voltage,
Innovation: GP335C series UPS is a quality product in a harmonic distortion, clutter interference, frequency wave
nominal capacity from 120KVA to 800KVA, had application power supply problems. Provide continuous, stable and pure
in key equipment for the power system protection, could sine wave power for the load.
provide high quality power, a high level of availability and • Adopt double DSP high speed digital signal processing
scalability, and invest minimize Total Cost of Ownership chip collaborative central CPU microprocessor common to
(TCO) Application the system control, feedback, measuring, display,
Mainly used in large IDC rooms, bank/securities settlement communication etc for all-round real-time processing, and
center, communication network management center, semi make the system parameters keep the same when
conductor product lines and large automation production environment (temperature, humidify, noise, etc.) charges.
with it's control system. According to the special needs of Even in the input signal distorted, can also provide accurate
users was improved, used in large sports venues, conference current, voltage, frequency and waveforms output. This
room, theater, highway and railway tunnels metal halide technology has powerful control functions, thus realizing the
lamp lighting system. computer system's comprehensive power
management.
Feature:
• Using advance 6th generations DSP and full digital control GP335C Series Working Principle:
technologies to realize higher system stability. • GP335C series UPS use AC-DC-AC converter. The rst
• Output power factor is 0.9, carrying capacity more than level transform (AC-DC) adopts SCR 3 -phase full controlled
conventional UPS with 10% above, as users reduce rectiers, 3-phase AC input voltage transform into stable DC
investment cost. bus voltage. Rectier hold concurrently and charger
• Advanced distributed active parallel technology can function, and adopts the advanced temperature
realize parallel operation of 6PCS UPS units without the need compensation technology, so that prolong battery life.
of centralized bypass cabinet. Inverter main power adopts high power insulation gate
• 6-inch extra large LCD that can display 12 language bipolar transistors (IGBT) as its inverter unit. Controller
(English, Russian, Spanish, French and so on) adopts advanced space vector pulse width modulation
• Extra wide input voltage and frequency range make it (SVPWM) technology. And the DC Bus voltage inverter back
adapt to severe power grid environment. to AC voltage.
• Intelligent battery management maintains battery
automatically to prolong the battery life. • Rectiers and inverter work at same time when the Utility
• Standard input/output lter improve the system EMC Power is normal, at the same time to supply power to the
load and to the battery charge. When the utility power
abnormalities, rectier stop working, turn by the battery by
inverter to power supply to the load. If the battery voltage
drops to discharge the termination voltage, and utility power
hasn't returned to normal, UPS will shutdown (if two utility
power different source and bypass the normal, system will let
bypass supply power). Battery discharge and terminate
voltage already preset. Inverter fault or overload, still can
have external communications bypass through bypass
switch Q2 and static bypass to supply power for the load. In
addition, is UPS need maintenance or repair, UPS can
through internal manual control maintenance bypass switch
Q3 to supply power to the load. UPS normal operation,
except maintenance bypass switch, all other switches are
closed.

www.poweronenertech.com 27

Technical Specifications

MODEL GP335C 120-800KVA

6P 12P 6P 12P 6P 12P 6P 12P 6P 12P 12P 12P 12P

Rated Nominal 120KVA/108KW 160KVA/144KVA 200KVA/180KVA 300KVA/270KVA 400KVA/360KVA 500KVA/450KVA 600KVA/540KVA 800KVA/720KVA

Rated Input Voltage 380/400/415VAC 3-phase 4-wire

Rated Frequency 50/60HZ

INPUT PARAMETERS

Input Voltage Range ±25%

Input Frequency Range 45Hz~65Hz

Input Soft Start Function 0-100% 5-300S settable

Input Power Factor >0.98 (if harmonic lter is added)

Input Harmonic current (THD) <4.5% (if harmonic lter is added)

BYPASS

Bypass Voltage Range -20%~+15%

Bypass Frequency Range 50/60HZ±10%

OUTPUT PARAMETERS

Inverter Output Voltage 380/400/415VAC 3-phase 4-wire

Voltage Stability ±1% (Steady status), ±3% (Transient status)

Frequency 50/60Hz

Mains power synchronization window ±5%

Actually measured frequency 50/60Hz±0.05Hz
accuracy (internal clock)

Output Power Factor 0.9 (output 90kW per 100kVA)

Transient Response Time <5ms

Inverter Overload Capacity At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s

Short circuit current from inverter 3ph 1.5 in for 5seconds, 1ph 2.9in for 5seconds

Maximum Bypass Capability 1000% for 100ms

Phase Shift Characteristic With 100% balanced load <1°
With 100% imbalance load <1°

Total Harmonic 100% linear load <1%
Distortion (THDv) 100% non-linear load <3%

System Efciency (full load) Up to 94% (Inverter efciency is up to 98%)

RECTIFIER OUTPUT PARAMETERS

Charger output voltage stability 1%

DC Ripple Voltage <1%

OPERATING ENVIRONMENT

Operating Temperature Range 0~40 C

Storage Temperature -25~70 C (Inverter efciency is up to 98%)

Relative Humidity 0~95% (Non-condensing)

Maximum Operating Height <Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m

NOISE (1M) 58-68dB

Protection level IP20

Standard Safety: IEC60950-1 IEC62040-1-1 UL 1778EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3

PHYSICAL PARAMETER

Weight (kg) 980 1420 1200 1750 1350 2000 1600 2200 2100 2750 3690 6390 7390

Dimensions : (WxDxH)mm 900X855X1900 1250X855X1900 1640X855X1900 1250X855X1900 1640X855X1900 2280X855X1900 2835X1000X1950 3955X1090X1950

www.poweronenertech.com 28

POWER PROTECTION GP 338C SERIES 10K, 15K, 20K, 30K, 40K, 60K, 80K,
100K, 120K, THREE PHASE IN /OUT
4.3.GP 338C 10-120KVA

Overview: • High Efciency Parallel System
GP 338C 10K-120K •UPS Group Synchroniser (optional )
Nominal Input Voltage 380/400/415vac • Parallel System Joiner ( Optional )
Output Power factor - 0.8 • Flexibility
Parallel : Maximum : 8pcs : Ups • Advanced Communication
Battery Can Be Shared In Parallel • Ease Of Installation

Feature:
• Absolute Protection
• Easy Source
• Power Continuity
• Maximum Levels Of Reliability And

Availability
• Hot System Expansion

www.poweronenertech.com 29

Technical Specifications

MODEL GP338C 10K GP338C 15K GP338C 20K GP338C 30K GP338C 40K GP338C60K GP338C 80K GP338C 100K GP338C 120K
Power (KVA) 10 15 20 30 40 60 80 100 120
INPUT
Nominal voltage 380/400/415VAC Three phase

Nominal Voltage tolerance 400 V + 20% / - 25%

Frequency 45+65Hz
Soft start 0+100% in 30" (selectable)
Permitted frequency tolerance ±2% (selectable from ± 1% to ±5% from the front panel)
Standard features Back Feed protection; separable bypass line

BATTERY lead, ooded and VRLA AGM / GB; NiCd
Type <1%
Ac ripple
Temperature compensation -0.5VxºC
Typical charging current 0.2xC10
OUTPUT

Rated power (KVA) 10 15 20 30 40 60 80 100 120

Active power (kw) 8 12 16 24 32 48 64 80 96
Number of phases 3+N

Nominal voltage 380/400/415VAC Three phase

Static stability ± 1%
Dynamic stability ±5% in 10 ms
Voltage distortion <1% with linear load / < 3% with no-Iineer load

Crest factor (Ipeak/Irms) 3:1
Frequency stability on battery mode 0.05%
Frequency 50 or 60 Hz (selectable)
Overload 110% for 60;125% for 10;150% for 1
ENVIRONMENTAL

Weight (kg) without batteries 210* 220* 230 280 330 450 600 640 650
Dimensions (hwd) (mm)
Remote signalling Voltage 1400X555X740 1400X800X740
Remote commands
Communication Voltage-free contacts
Operating temperature
Relative humidity EPO and bypass
Colour
double RS232+ remote contacts + 2 communication interface slots+ Modbus Protocal

0°C+/45°C

<95% non condensing
Light Grey &. Black

Noise 54 60 62 63+68 dBA at 1m

Protection rating IP20
Efciency Smart Made Up to 98%
Compliance European Directives : l V 2006/95/CE: EMC 2004/108/ECl: Safety IEC 62040-1: EMC IEC EN 62040-2 C2

Classication according to (Voltage Frequency lndependent) VFl-SS-111
IEC 62040-3

SPECIAL FEATURES

Galvanized Isolation Output Transformer, Input Harmonic Filter, MuIti Language Large Touch Screen Display

www.poweronenertech.com 30

POWER PROTECTION GP 338C II SERIES 10K-120K 3/3 Phase Online LF UPS
POWER FACTOR 0.8
4.4.GP 338CS 10-120K

10-40kVA 60-80kVA 100-120kVA

Overview: Feature:
GP 338C II Series is upgraded DSP controlled • Maximum Reliability
Online LF UPS with output isolation • High Speed DSP Processor
transformer. It can be your perfect large • Output 100% Unbalance Load
capacity power shield for your critical and • ECO Function
industrial load. • UPS For Industrial Loads
PERFECT APPLICAITON: Middle and large • Operating Flexibility
data center, Telecom, Finance, Traffic, • Colorful Multifuctional Panel
Defense, Medical, Education, Energy, • Advanced Battery Management (ABM)
Manufacture, Industry, etc. • Maximum Safety For Personnel
• Full Front Access And Convenient Cable

Connection
• Perfect Human-machine Communication

www.poweronenertech.com 31

Technical Specifications

MODEL GP 338CS 10K GP 338CS 15K GP 338CS 20K GP 338CS 30K GP 338CS 40K GP 338CS 60K GP 338CS 80K GP 338CS 100K GP 338CS 120K
Capacity
10kVA 15kVA 20kVA 30kVA 40kVA 60kVA 80kVA 100kVA 120kVA
SYSTEM
Output PF 0.8(lag)

System efciency (inverter mode) 92%(@100% load) ;90% @50%load;

System efciency (ECO mode) 98%(@100%load)
Maximum leakage current 100(mA)

MTBF Above 200,000hours
Dry contact Standard: 3 types signal(BAT. low,battery mode,bypass /failure);Optional:14 dry contact ; output: 12Vdc 80mA

Communication interface Standard RS232,optional: RS485 / MODBUS
Operation temperature 0 ~ 40 °C

Humidity 95 % (non-condense)

Cooling Forced air (speed varying according to load percent)

Max. altitude Within 1000m(every 100increase,capacity decrease -1%),Maximum 4000m

Noise (dB) 52 ~ 58
IP protection (EN 60529) IP20
Input/output way
Bottom /rear

Safety standard safety:GB4943 ,EN 50091-1; EMI:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2

PHYSICAL

WxDxH(mm) 600*600*1280 800*800*1480 800*800*1800
Weight(Kg)
AC INPUT 195 210 220 305 340 500 600 800 950

Rated voltage 380/400/415Vac Three-phase four-wires
Input voltage range ± 15 % (± 25 % adjustable)

Rate frequency 50 / 60 Hz auto-sense
Frequency range 50/60Hz ± 5Hz

Input soft start function 0 - 100%,10-300s(settable)

Input power factor Reachable 0.99 (plus harmonic lter)

Input current harmonic component (THDi) Can <5% (plus harmonic lter)

Max. input current [A] 18 27 36 54 72 108 144 180 216

THE OUTPUT CHARACTERISTIC OF THE RECTIFIER

Battery type1 and 2 :V =435Vdc (2.266 x el.)

Maintain the voltage (20°C) Battery type 3 :V =424Vdc (2.21 x el.)

Battery type 0:the voltage value between type 1and 2, Voltage regulating range: V =400~460Vdc

Charging voltage (20°C) Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.)
Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)

Battery type 0: the voltage value between type 1and 2, Voltage regulating range: V =400~460Vdc

The highest charging voltage 445V

The charger output voltage 1%
regulation accuracy

DC ripple voltage component ≤1%

BATTERY

Unit number(rated voltage) 384VDC(360-384v,selectable)

Charging current settings 0.1C(battery capacity)

The battery discharge Battery type 1,2 and 3:no-load discharge current, V min=346 [Vdc]
Battery type 1,2 and 3:output current =Ah capacity, V min=316 [Vdc]

end voltage Battery type 1,2 and 3:output current >Ah capacity, V min=306 [Vdc]

Battery type 0: the factory set the default values, V min=320 [Vdc], Regulating range: V min =300~360[V dc]

INVERTER OUTPUT

Rated capacity [kVA] 10 15 20 30 40 60 80 100 120

Rated power [KW] 8 12 16 24 32 48 64 80 96

Rated voltage [V] 380/400/415VacThree-phase four-wires

Rated current [A] 12 18 24 36 48 72 96 120 144

Phase voltage setting 200 ~ 244 V (control board)

Peak factor 3:1

Waveform Sine wave

Voltage phase shift (degrees) 100% balanced load ± 1'
100% unbalanced load ± 2'

Phase voltage difference 100% balanced load ± 1 %
100% unbalanced load ± 3 %

Total harmonic content(THDv) 100% linear load <2%
100% non-linear load <5%

Steady-state voltage stability ±1%

Transient voltage response ± 5 % within 10ms

Rated frequency Same as input

Frequency stability When asynchronous,± 0.5 %; synchronization,± 2 % (can be set to ± 1~5 %,by the panel operation)

Overload 600’ / 10’ / 1’ (110/125/150% rated current)

Short circuit 0.1s Double input

Inverter efciency(load 100%) 98%

BYPASS

Rated capacity [kVA] 10 15 20 30 40 60 80 100 120

Rated voltage [V] 380/400/415VacThree-phase four-wires

Input voltage range ±15 % (can be adjusted from the control panel ± 10 %,± 20%)

Rated frequency [Hz] 50 / 60

Frequency range ±2 % (can be adjusted from the control panel ± 5 %)

Transfer time “STAND-BY ON” (Eco mode, the bypass switch to inverter) 2~5ms

Inverter/bypass transfer time <1ms

Overload 10’/1’/18” (150/175/200% Rated current)

Standard conguration Feed ow protection, bypass independently isolated

www.poweronenertech.com 32

POWER PROTECTION GP 338C II SERIES 160K-400K 3/3 Phase Online LF UPS
POWER FACTOR 0.8
4.5.GP 338CS 160-400K

160-400kVA

Overview: Feature:
GP 338C II Series is upgraded DSP controlled • Maximum Reliability
Online LF UPS with output isolation • High Speed DSP Processor
transformer. It can be your perfect large • Output 100% Unbalance Load
capacity power shield for your critical and • ECO Function
industrial load. • UPS For Industrial Loads
PERFECT APPLICAITON: Middle and large • Operating Flexibility
data center, Telecom, Finance, Traffic, • Colorful Multifuctional Panel
Defense, Medical, Education, Energy, • Advanced Battery Management (ABM)
Manufacture, Industry, etc. • Maximum Safety For Personnel
• Full Front Access And Convenient Cable

Connection
• Perfect Human-machine Communication

www.poweronenertech.com 33

Technical Specifications

MODEL GP 338CS 160K GP 338CS 200K GP 338CS 250K GP 338CS 300K GP 338CS 350K GP 338CS 400K

Capacity 160kVA 200kVA 250kVA 300kVA 350kVA 400kVA
6P 12P 6P 12P 6P 12P 6P 12P 6P 12P 6P 12P

SYSTEM PARAMETER

Output PF 0.8(lag)

Overall efciency (normal model) Load 100% 94%

Load 50% 92%

Overall efciency:(ECO mode)Load 100% 98%

Maximum leakage current(mA) 100

Standby economic model Standard functions

MTBF Above 200,000 hours

Dry contact signal Standard three control signal (battery low,battery discharge,bypass/breakdown);Optional 14 control signal;output 12Vdc 80mA

Computer monitors port Standard S232,optional ODBUS

Running temperature 0 ~ 40 °C

Maximum relative humidity 95 % (non-condensing)

Cooling Forced ventilation (fan speed changing with load)

Maximum altitude 1000m rated power(Rising 100m lower 1%) maximum 4000m

Noise (dB) 54 ~ 62

Protection class (EN 60529) IP20

Inlet and outlet of the wire way Bottom /rear

Safety standard Safety: GB4943,EN 50091-1 electromagnetic compatibility: GB7260.2,GB/T 17626.2~5EMC,EN 50091-2

PHYSICAL PARAMETER

Wide (mm) 1100 1400 1100 1400 1400 1400 1400 1400 1600 1600 1600 1600

Deep*high (mm) 800*1800 1000*2000 1100*2000

Weight(Kg) 1200 1550 1350 1750 1500 1950 1650 2150 1850 2400 2100 2700

THE INPUT RECTIFIER FEATURES

Rated voltage 380/400/415Vac Three-phase four-wires

Input voltage range ± 15 % (± 25 % adjustable)

Rate frequency 50 / 60 Hz automatic identication

Frequency range 45 ~ 65

Input soft start function Yes,0 - 100%,can be set to 10-300 seconds

Input power factor cosҨ Reachable 0.99(plus harmonic lter)

Input current harmonic component (THDi) Can <5% (plus harmonic lter)

Max. input current [A] 250 315 400 500 550 630

THE OUTPUT CHARACTERISTIC OF THE RECTIFIER

Maintain the voltage (20°C) Battery type1 and 2 :V =435Vdc (2.266 x el.) Battery type1 and 2:V =544Vdc (2.266 x el.)
Battery type 3 :V =424Vdc (2.21 x el.) Battery type 3:V =530Vdc (2.21 x el.)
Charging voltage (20°C)
Battery type 0:the voltage value between type 1and 2, Battery type 0:the voltage value between type 1
The highest charging voltage Voltage regulating range: V =400~460Vdc and 2, Voltage regulating range: V =500~575Vdc
The charger output voltage
regulation accuracy Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.) Battery type1 and 2: V(%recharging<95%)
=557Vdc (2.32 x el.)
Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)
Battery type 3 :V(%recharging<95%)
Battery type 0: the voltage value between type 1and 2, =576Vdc (2.4 x el.)
Voltage regulating range: V =400~460Vdc
445V Battery type 0:the voltage value between type 1
and 2, Voltage regulating range: V =500~575Vdc
1%
556V

DC ripple voltage component ≤1% 240 units(480VDC)
BATTERY
Unit number(rated voltage) 192 units (384VDC) Battery type 1,2 and3:no-load
Charging current settings 0.1C(battery capacity) discharge current,Vmin=433 [Vdc]
Battery type 1,2 and 3: output current
The battery discharge Battery type 1,2 and 3:no-load discharge current, V min=346 [Vdc]
end voltage =Ah capacity, Vmin=395 [Vdc]
Battery type 1,2 and 3:output current =Ah capacity, V min=316 [Vdc] Battery type 1,2 and 3: output current

Battery type 1,2 and 3:output current >Ah capacity, V min=306 [Vdc] >Ah capacity, Vmin=383 [Vdc]

Battery type 0: the factory set the default values, V min=320 [Vdc], Battery type 0:the factory set the default values,Vmin=
Regulating range: V min =300~360[Vdc] 400 [Vdc] Regulating range: Vmin =375~450V[Vdc]

INVERTER OUTPUT 160 200 250 300 350 400
Rated capacity [kVA]
Rated power [KW] 128 160 200 240 280 320
Rated voltage [V] 380/400/415VacThree-phase four-wires
Rated current [A]
Phase voltage setting 195 243 304 365 426 486
Peak factor 200 ~ 244 V (control board)
Waveform 3:1
Sine wave
Voltage phase shift (degrees) 100% balanced load ± 1'
100% unbalanced load ± 2'

Phase voltage difference 100% balanced load ± 1 %
100% unbalanced load ± 3 %
Total harmonic content(THDv)
100% linear load <2%
Steady-state voltage stability 100% non-linear load <5%
Transient voltage response
Rated frequency ±1%
Frequency stability ± 5 % within 10ms
Overload
Short circuit 0.1s Same as input
Inverter efciency(load 100%) When asynchronous,± 0.5 %; synchronization,± 2 % (can be set to ± 1~5 %,by the panel operation)
BYPASS
Rated capacity [kVA] 600’ / 10’ / 1’ (110/125/150% rated current)
Rated voltage [V] Double input
Input voltage range 98%

160 200 250 300 350 400
380/400/415VacThree-phase four-wires

±15 % (can be adjusted from the control panel ± 10 %,± 20%)

Rated frequency [Hz] 50 / 60
Frequency range ±2 % (can be adjusted from the control panel ± 5 %)
Conversion time “STAND-BY ON” (Eco mode, the bypass switch to inverter) 2~5ms
Inverter/bypass transfer time
Overload <1ms
Standard conguration 10’/1’/18” (150/175/200% Rated current)
Feed ow protection, bypass independently isolated

www.poweronenertech.com 34

POWER PROTECTION GP 339C II SERIES 10K-120K 3/3 PHASE ONLINE LF UPS
POWER FACTOR 0.9
4.6.GP 339CS 10-120K

10-40kVA 60-80kVA 100-120kVA

Overview: Feature:
GP 339C II Series is upgraded DSP controlled • Maximum Reliability
Online LF UPS with output isolation • High Speed DSP Processor
transformer. It can be your perfect large • Output 100% Unbalance Load
capacity power shield for your critical and • ECO Function
industrial load. • UPS For Industrial Loads
PERFECT APPLICAITON: Middle and large • Operating Flexibility
data center, Telecom, Finance, Traffic, • Colorful Multifuctional Panel
Defense, Medical, Education, Energy, • Advanced Battery Management (ABM)
Manufacture, Industry, etc. • Maximum Safety For Personnel
• Full Front Access And Convenient Cable

Connection
• Perfect Human-machine Communication

www.poweronenertech.com 35

Technical Specifications

MODEL GP 339CS 10K GP 339CS 15K GP 339CS 20K GP 339CS 30K GP 339CS 40K GP 339CS 60K GP 339CS 80K GP 339CS 100K GP 339CS 120K
Capacity
10kVA 15kVA 20kVA 30kVA 40kVA 60kVA 80kVA 100kVA 120kVA
SYSTEM
Output PF 0.9(lag)

System efciency (inverter mode) 92%(@100% load) ;90% @50%load;

System efciency (ECO mode) 98%(@100%load)
Maximum leakage current 100(mA)

MTBF Above 200,000hours
Dry contact Standard: 3 types signal(BAT. low,battery mode,bypass /failure);Optional:14 dry contact ; output: 12Vdc 80mA

Communication interface Standard RS232,optional: RS485 / MODBUS
Operation temperature 0 ~ 40 °C

Humidity 95 % (non-condense)

Cooling Forced air (speed varying according to load percent)

Max. altitude Within 1000m(every 100increase,capacity decrease -1%),Maximum 4000m

Noise (dB) 52 ~ 58
IP protection (EN 60529) IP20
Input/output way
Bottom /rear

Safety standard safety:GB4943 ,EN 50091-1; EMI:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2

PHYSICAL

WxDxH(mm) 600*600*1280 800*800*1480 800*800*1800
Weight(Kg)
AC INPUT 195 210 220 305 340 500 600 800 950

Rated voltage 380/400/415Vac Three-phase four-wires
Input voltage range ± 15 % (± 25 % adjustable)

Rate frequency 50 / 60 Hz auto-sense
Frequency range 50/60Hz ± 5Hz

Input soft start function 0 - 100%,10-300s(settable)

Input power factor Reachable 0.99 (plus harmonic lter)

Input current harmonic component (THDi) Can <5% (plus harmonic lter)

Max. input current [A] 18 27 36 54 72 108 144 180 216

THE OUTPUT CHARACTERISTIC OF THE RECTIFIER

Battery type1 and 2 :V =435Vdc (2.266 x el.)

Maintain the voltage (20°C) Battery type 3 :V =424Vdc (2.21 x el.)

Battery type 0:the voltage value between type 1and 2, Voltage regulating range: V =400~460Vdc

Charging voltage (20°C) Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.)
Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)

Battery type 0: the voltage value between type 1and 2, Voltage regulating range: V =400~460Vdc

The highest charging voltage 445V

The charger output voltage 1%
regulation accuracy

DC ripple voltage component ≤1%

BATTERY

Unit number(rated voltage) 384VDC(360-384v,selectable)

Charging current settings 0.1C(battery capacity)

The battery discharge Battery type 1,2 and 3:no-load discharge current, V min=346 [Vdc]
Battery type 1,2 and 3:output current =Ah capacity, V min=316 [Vdc]

end voltage Battery type 1,2 and 3:output current >Ah capacity, V min=306 [Vdc]

Battery type 0: the factory set the default values, V min=320 [Vdc], Regulating range: V min =300~360[V dc]

INVERTER OUTPUT

Rated capacity [kVA] 10 15 20 30 40 60 80 100 120

Rated power [KW] 9 13.5 18 27 36 54 72 90 108

Rated voltage [V] 380/400/415VacThree-phase four-wires

Rated current [A] 12 18 24 36 48 72 96 120 144

Phase voltage setting 200 ~ 244 V (control board)

Peak factor 3:1

Waveform Sine wave

Voltage phase shift (degrees) 100% balanced load ± 1'
100% unbalanced load ± 2'

Phase voltage difference 100% balanced load ± 1 %
100% unbalanced load ± 3 %

Total harmonic content(THDv) 100% linear load <2%
100% non-linear load <5%

Steady-state voltage stability ±1%

Transient voltage response ± 5 % within 10ms

Rated frequency Same as input

Frequency stability When asynchronous,± 0.5 %; synchronization,± 2 % (can be set to ± 1~5 %,by the panel operation)

Overload 600’ / 10’ / 1’ (110/125/150% rated current)

Short circuit 0.1s Double input

Inverter efciency(load 100%) 98%

BYPASS

Rated capacity [kVA] 10 15 20 30 40 60 80 100 120

Rated voltage [V] 380/400/415VacThree-phase four-wires

Input voltage range ±15 % (can be adjusted from the control panel ± 10 %,± 20%)

Rated frequency [Hz] 50 / 60

Frequency range ±2 % (can be adjusted from the control panel ± 5 %)

Transfer time “STAND-BY ON” (Eco mode, the bypass switch to inverter) 2~5ms

Inverter/bypass transfer time <1ms

Overload 10’/1’/18” (150/175/200% Rated current)

Standard conguration Feed ow protection, bypass independently isolated

www.poweronenertech.com 36

POWER PROTECTION GP 339C II SERIES 160K-400K 3/3 Phase Online LF UPS
POWER FACTOR 0.9
4.7.GP 339CS 160-400K

160-400kVA

Overview: Feature:
GP 338C II Series is upgraded DSP controlled • Maximum Reliability
Online LF UPS with output isolation • High Speed DSP Processor
transformer. It can be your perfect large • Output 100% Unbalance Load
capacity power shield for your critical and • ECO Function
industrial load. • UPS For Industrial Loads
PERFECT APPLICAITON: Middle and large • Operating Flexibility
data center, Telecom, Finance, Traffic, • Colorful Multifuctional Panel
Defense, Medical, Education, Energy, • Advanced Battery Management (ABM)
Manufacture, Industry, etc. • Maximum Safety For Personnel
• Full Front Access And Convenient Cable

Connection
• Perfect Human-machine Communication

www.poweronenertech.com 37

Technical Specifications

MODEL GP 339CS 160K GP 339CS 200K GP 339CS 250K GP 339CS 300K GP 339CS 350K GP 339CS 400K

Capacity 160kVA 200kVA 250kVA 300kVA 350kVA 400kVA
6P 12P 6P 12P 6P 12P 6P 12P 6P 12P 6P 12P

SYSTEM PARAMETER

Output PF 0.9(lag)

Overall efciency (normal model) Load 100% 94%

Load 50% 92%

Overall efciency:(ECO mode)Load 100% 98%

Maximum leakage current(mA) 100

Standby economic model Standard functions

MTBF Above 200,000 hours

Dry contact signal Standard three control signal (battery low,battery discharge,bypass/breakdown);Optional 14 control signal;output 12Vdc 80mA

Computer monitors port Standard S232,optional ODBUS

Running temperature 0 ~ 40 °C

Maximum relative humidity 95 % (non-condensing)

Cooling Forced ventilation (fan speed changing with load)

Maximum altitude 1000m rated power(Rising 100m lower 1%) maximum 4000m

Noise (dB) 54 ~ 62

Protection class (EN 60529) IP20

Inlet and outlet of the wire way Bottom /rear

Safety standard Safety: GB4943,EN 50091-1 electromagnetic compatibility: GB7260.2,GB/T 17626.2~5EMC,EN 50091-2

PHYSICAL PARAMETER

Wide (mm) 1100 1400 1100 1400 1400 1400 1400 1400 1600 1600 1600 1600

Deep*high (mm) 800*1800 1000*2000 1100*2000

Weight(Kg) 1200 1550 1350 1750 1500 1950 1650 2150 1850 2400 2100 2700

THE INPUT RECTIFIER FEATURES

Rated voltage 380/400/415Vac Three-phase four-wires

Input voltage range ± 15 % (± 25 % adjustable)

Rate frequency 50 / 60 Hz automatic identication

Frequency range 45 ~ 65

Input soft start function Yes,0 - 100%,can be set to 10-300 seconds

Input power factor cosҨ Reachable 0.99(plus harmonic lter)

Input current harmonic component (THDi) Can <5% (plus harmonic lter)

Max. input current [A] 250 315 400 500 550 630

THE OUTPUT CHARACTERISTIC OF THE RECTIFIER

Maintain the voltage (20°C) Battery type1 and 2 :V =435Vdc (2.266 x el.) Battery type1 and 2:V =544Vdc (2.266 x el.)
Battery type 3 :V =424Vdc (2.21 x el.) Battery type 3:V =530Vdc (2.21 x el.)
Charging voltage (20°C)
Battery type 0:the voltage value between type 1and 2, Battery type 0:the voltage value between type 1
The highest charging voltage Voltage regulating range: V =400~460Vdc and 2, Voltage regulating range: V =500~575Vdc
The charger output voltage
regulation accuracy Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.) Battery type1 and 2: V(%recharging<95%)
=557Vdc (2.32 x el.)
Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)
Battery type 3 :V(%recharging<95%)
Battery type 0: the voltage value between type 1and 2, =576Vdc (2.4 x el.)
Voltage regulating range: V =400~460Vdc
445V Battery type 0:the voltage value between type 1
and 2, Voltage regulating range: V =500~575Vdc
1%
556V

DC ripple voltage component ≤1% 240 units(480VDC)
BATTERY
Unit number(rated voltage) 192 units (384VDC) Battery type 1,2 and3:no-load
Charging current settings 0.1C(battery capacity) discharge current,Vmin=433 [Vdc]
Battery type 1,2 and 3: output current
The battery discharge Battery type 1,2 and 3:no-load discharge current, V min=346 [Vdc]
end voltage =Ah capacity, Vmin=395 [Vdc]
Battery type 1,2 and 3:output current =Ah capacity, V min=316 [Vdc] Battery type 1,2 and 3: output current

Battery type 1,2 and 3:output current >Ah capacity, V min=306 [Vdc] >Ah capacity, Vmin=383 [Vdc]

Battery type 0: the factory set the default values, V min=320 [Vdc], Battery type 0:the factory set the default values,Vmin=
Regulating range: V min =300~360[Vdc] 400 [Vdc] Regulating range: Vmin =375~450V[Vdc]

INVERTER OUTPUT 160 200 250 300 350 400
Rated capacity [kVA]
Rated power [KW] 144 180 225 270 315 360
Rated voltage [V] 380/400/415VacThree-phase four-wires
Rated current [A]
Phase voltage setting 195 243 304 365 426 486
Peak factor 200 ~ 244 V (control board)
Waveform 3:1
Sine wave
Voltage phase shift (degrees) 100% balanced load ± 1'
100% unbalanced load ± 2'

Phase voltage difference 100% balanced load ± 1 %
100% unbalanced load ± 3 %
Total harmonic content(THDv)
100% linear load <2%
Steady-state voltage stability 100% non-linear load <5%
Transient voltage response
Rated frequency ±1%
Frequency stability ± 5 % within 10ms
Overload
Short circuit 0.1s Same as input
Inverter efciency(load 100%) When asynchronous,± 0.5 %; synchronization,± 2 % (can be set to ± 1~5 %,by the panel operation)
BYPASS
Rated capacity [kVA] 600’ / 10’ / 1’ (110/125/150% rated current)
Rated voltage [V] Double input
Input voltage range 98%

160 200 250 300 350 400
380/400/415VacThree-phase four-wires

±15 % (can be adjusted from the control panel ± 10 %,± 20%)

Rated frequency [Hz] 50 / 60
Frequency range ±2 % (can be adjusted from the control panel ± 5 %)
Conversion time “STAND-BY ON” (Eco mode, the bypass switch to inverter) 2~5ms
Inverter/bypass transfer time
Overload <1ms
Standard conguration 10’/1’/18” (150/175/200% Rated current)
Feed ow protection, bypass independently isolated

www.poweronenertech.com 38

POWER PROTECTION GP 339 SERIES 500KVA, 600KVA, 800KVA 3 PHASE
IN / 3 PHASE OUT PF:0.9
4.8.GP 339CS SERIES
500-800KVA

Super wide input voltage/frequency range,
adapt to harsh utility environments.
Higher overload capacity and output short-
tolerant ability.
Input power factor up to 0.95 with input lter
options, input THDi<4.5%.
Output power factor 0.9, brings 12.5% more
power than traditional UPS.
Intelligent self diagnosis, mass memory to
record operation log.
Super long MTBF and short MTTR.
Intelligent parallel and parallel ECO Mode.

2.Reliability

Overview: Fully digital control with the most advanced
This GP series large power UPS is true online, DSP processor, higher system reliability.
double conversion topology, with most Redundant fan design, enhance system
innovative design and patents, power your reliability.
business with the highest power quality. Build-in output isolation transformer,
Environment friendly, high efciency and eliminate neutral to ground drifting voltage,
high reliability provide the lowest TCO (Total and isolate load harmonic current inuence
Cost of Ownership). to inverter.
This series UPS is fully digital controlled, More than 90% components are from world
armed with several DSP, MCU, CPLD, and it well-known tier 1 suppliers, 100% IQC
can parallel up to 8 units for redundancy or inspected. All nal products will pass internal
capacity.It is truly a perfect high quality and test procedure and 24 Hours burn-in before
innovational solutions to protect your large delivery, increase the system reliability.
and critical equipments from any power
problems 3.Abundant options

Feature: Build-in various communication connectors
1.Leading technology (RS232, RS485, AS400, EPO etc).
Optional cards available: SNMP, battery
Advanced SCR rectier and IGBT inverter management kit, lighting proof module, dust
control technology, true online double proof lter etc.
conversion topology, three phase in three
phase out, 380/400/415V, 50/60Hz 4.Operation
compatible.
Front side maintenance, top or bottom wiring
connection, with protection equipments.
Friendly human machine interface, easy
operation with large LCD panel and
keyboards.

www.poweronenertech.com 39

Technical Specifications

MODEL GP 339 500k GP 339 600k GP 339 800k
Capacity(VA/Watts) 500 / 450 600 / 540 800 / 720
INPUT

Wiring connection Three phase+Ground
Nominal voltage 380/400/415VAC
Voltage range 285VAC~498VAC
Frequency 50/60Hz

Frequency range 45-65Hz
Soft start 5-600sec settable
Power factor 0.95 (with input lter)

BYPASS

Nominal voltage 380/400/415VAC (Three phase+Neutral+Ground)
Frequency 50/60Hz ± 10%
Voltage range
± 10%,± 15%,± 20% settable

OUTPUT

Nominal voltage 380/400/415VAC (Three phase+Neutral+Ground)

Voltage regulation ± 1% (balance load), ± 2% (100% unbalance load)

Power factor 0.9

Dynamic response ± 5% (0 ~ 100% load transient)
Distortion <1%(100% linear load), <3%(100% non-linear load)

Transient response < 5ms
Sync. Range ± 2Hz (±0.5 - ±3Hz settable)
Overload 105% continue, 110% 1Hr, 125% 10min, 150% 1min

Frequency ± 0.05%
Waveform Pure sine wave
EFFICIENCY

Inverter mode Up to 94%

ECO mode 98%
PARALLEL

N+X Max 8 units

BATTERY

Conguratation 12V, 40 pieces default (38~42pieces settable)

DISPLAY

LCD + LED

PHYSICAL

Dimension D X W X H (mm) 855 X 2700 X 1900 855 X 3000 X 1900 855 X 3800 X 1900

Net weight (kg) 3000 3500 4100

ENVIRONMENTAL

Temperature 0 ~ 40°C
Humidity 0 ~ 95% (non condensing)

Noise (1m) 71dB 73dB 76dB
CONNECTIVE

RS-232/(USB option) Support windows2000/XP/7/Linux/Unix/Mac
SNMP Support remote control through web browser

STANDARDS IEC60950-1,IEC62040-1-1
Safety IEC62040-2,IEC62040-3
EMC

www.poweronenertech.com 40

POWER PROTECTION 5. HF ONLINE UPS - 3:3

5.1.Value Series 10-120KVA PHV Series 3/3phase Online HF UPS 10-120kVA
with PF0.9

Overview: • Comprehensive protection measures
PHV series 3 phase 10-120kVA is a high end Surge Protection, short circuit protection, and other
uninterruptible power supply, which has adopted the world protection to ensure the reliability of UPS system;
leading electrical and electronic technology to increase IGBT and SCR adopt the advanced EUPEC power module;
performance and super high reliability(MTBT>200,000h). The adoption of advanced technology (IGBT driving
3nos high speed DSPs with completed digital control fully technology, IGBT soft over-current shutdown, VCE
ensure highest quality of power supply and UPS reliability. protection) highly improves the reliability and safety of
Being kin to 1.0 input power factor and less than 2% THDi inverter.
lead this UPS green and energy saved. It also offers • Similar modular design
humanization design: full front access of service ability, user- Each phase main board are designed like rack for easy
friendly touch screen.(optional ) assembling and maintenance
Perfect Applications: Inbuilt battery pack plug-in design for easy use
Internet Service, Middle Data Center, Medium-scale • Intelligent battery management (ABM)
network system / computing center, bank and securities, Adopting the intelligent battery management, extending
business server group, Medium-scale office automation, battery lifespan extremely;
precision equipment, etc. Intelligent interval three-stage charging process( constant
current, constant voltage, oat charging and charger shut
Feature: off, when battery voltage decrease to a lower level,
• Complete digital control technology charger restarts to work);
Fully digital control with two DSPs, all the subsystems are Automatic temperature compensation,( -0.11% per °C ), to
digital controlled including the IGBT rectier, inverter, extremely extend battery life by 30% and minimize the
charger, discharger. maintaining work;
• Excellent electrical properties Online detecting battery status The max battery charging
True online double conversion offers the safe and effective current can set by end users according to the battery
power protection for various loads, with strong output load features, to avoid any damage caused by the big charging
capacity current; Back up time displayed on the LCD screen
• High input power factor, green and energy-saving Periodic self-test battery, detecting the battery problems
Input with PFC and input PF of the whole UPS up to 0.99, timely With battery inverse connection, over voltage /
THDi less than 2% current protection, to protect the battery
• Dual AC input source supportable
Supportable AC and bypass separate input AC source Online detecting battery status The max battery charging
• Strong environmental adaptability current can set by end users according to the battery
Wide input voltage and frequency range, adaptation to all features, to avoid any damage caused by the big charging
kinds of power grid and almost any kinds of generator current; Back up time displayed on the LCD screen Periodic
self-test battery, detecting the battery problems timely
With battery inverse connection, over voltage / current
protection, to protect the battery
• Cold start and AC start Function
Directly start the UPS through battery or start UPS through
Mains only.
• Superior network monitoring capabilities
Communication port (RS232, RS485, dry contact and so
on) connecting with computer, SNMP card optional,
• Easy-maintenance design (mmTM<0.5h)
a) Adopts the full front maintenance design, reducing the
restrictions on the installation space, and saving the space
of computing center
b) Modular design class, convenient and easy site
maintenance
c) With manual maintain bypass
d) Battery replacement without disrupting the UPS running
e) Historical records classied with search function, events
up to1,000 items
• Advanced parallel technology:
With digital control technology for cycle current control,
parallel system with very high reliable and up to 6units,
and sharing common battery;
Friendly interface with Large LCD with multi language
display (7 languages)
Large LCD display and LED status indication; Abundant
information display of UPS English, Spanish, Portuguese,
Russian etc

www.poweronenertech.com 41

Technical Specifications

MODEL PHV339-10 PHV339-15 PHV339-20 PHV339-30 PHV339-40 PHV339-60 PHV339-80 PHV339-100 PHV339-120

Rating Power 10kVA/ 15kVA/ 20kVA/ 30kVA/ 40kVA/ 60kVA/ 80kVA/ 100kVA/ 120kVA/
AC INPUT 9kW 13.5kW 18kW 27kW 36kW 54kW 72kW 90kW 108kW

Rated voltage 380/400/415Vac(Line-Line)
Input connection 3phase +N+PE
Power factor Above 0.999

THDi Less 2%

Voltage range -40%~+25%
Frequency 40-70Hz
Bypass
OUTPUT +/- 15%(settable)
Power factor
0.9 (lag)

Voltage Precision 380/400/415Vac±0.5%
Dynamical volt. transient Less 5% ( 0~100% load step)
THDU THD less 0.6% ( linear load), 3%(non-linear load)
Crest Factor
Freq. tracking range 3:1
50/60Hz±3Hz

Output Freq.precision ±0.05%(Battery mode) , ±3hz(Line mode)

Phase displacement 120±0.5°(Balance or imbalance load )
Voltage unbalance +/-3%( 100% unbalance load)
Freq. tracking rate Less 1Hz/s

Overload capability 110%:1hour,110%<load<125%,transfer to bypass after 10 mins
125%<load<150%,transfer to bypass after 1 mins, Above 150%, transfer to bypass after 200ms
Bypass overload
SYSTEM Below125% long time operation 125%<Load<150%,10mins;above 150% 1S

System 93-94%(Line and battery mode) Above 94%(Line and battery mode)
efciency 98%(ECO mode)

Display Large LCD screen (Touch screen optional)

IEC62040-2

EMC IEC61000-4-2 (ESD)
IEC61000-4-3 (RS)

IEC6100-4-4 (EFT)

IEC6100-4-5 (Surge)

Noise (1m) 50- 60dB
Insulating resistance Above 2M (500VDC)
Insulating intensity (input, output to PE) 2820Vdc, leakage current lower than 3.5mA, no ashover in 1min
Surge protection Meet the requirement of IEC60664-1class,endure surge of 1.2/50us+8/20us higher than 6KV/3KA

IP class IP20
BATTERY CONFIGURATION

Installation(dc) +/-216Vdc( 168/192/216/240Vdc settable from LCD screen)

Battery type Free Maintenance Lead Acid (Gel battery)

Long run Battery to be connected external

Inbuilt battery 36pcs *7AH 36pcs *7AH 36pcs *9AH 72pcs *7AH 72pcs *9AH

Connection Bottom cable connection in front

Charger 1-15A,ABM technology (settable from LCD) 10-40A( settable from LCD screen)
PHYSICAL 660*700*1520 mm
Dimension (Long-run) 370*782*902mm (W*D*H) 500*717*1146 mm(W*D*H)
370*782*978mm (W*D*H) 500*717*1546 mm(W*D*H)
Dimension (Inbuilt batt.)

Packing Dimension 784*824*1712 mm

Weight (kg)(Long -run) 80/108 130/163 133/166 245/280 260/295 275/310 305/340

Weight (kg) 148/176 170/190 305/344 344/383
(Inbuilt Batt.)
10kVA and 15kVA:inbuilt 36pcs 7AH (72pcs 7AH) (72pcs 9AH)
20kVA: inbuilt 36pcs 9AH

Note: For 110/120/127Vac (L-N), 60Hz 3phase, 10-80kVA available;

www.poweronenertech.com 42

POWER PROTECTION

5.2.Prime Series 15K-400KVA PHP Series Online HF UPS 15KVA-400kVA

Overview: surge protection and Unlike most high
PHP series Online HF UPS provide effective efciency UPS in ECO mode
data-center solution with advanced
hardware and rich design features. It is • Real compatibility
adopted world leading technology and • True reliability
gained numbers of revolutionary • Hot Sync technology makes it possible to
technological breakthrough, which has parallel up to four UPSs to increase availability
leaded it become a complete high level or add capacity.
reliable product with excellent performance.
• Compact & serviceable design
Feature:
• Energy-efficiency design • Separate SPS for bypass and main system
• With a transformer-free design Besides the SPS with reliable double circuit
• sophisticated sensing and control circuitry design but also the SPS of bypass is separated,
which can ensure even the main system SPS
•HE mode: High efciency mode with surge failed, UPS can transfer to bypass successfully.
protection up to a 98.5% rating, making it
one of the most energy-efcient UPS. • ABM battery management
•And it still provides maximum load
protection, within 4-6ms transfer time and

www.poweronenertech.com 43

Technical Specifications

MODEL PHP PHP PHP PHP PHP PHP PHP PHP PHP PHP PHP PHP
339 15 339 20 339 30 339 40 339 60 339 80 339 100 339 120 339 160 339 200 339 300 339 400

Capacity(kW) 13.5 18 27 36 54 72 90 108 144 180 240 360
UPS efciency
94% (Full load on inverter-mode)

Standby 98.5% on HE mode, reliable protects load

Power expand Easy expand capacity or redundancy via Hot-Sync
Topology IGBT ON-Line Dual Conversion
AC TO DC RECTIFY

IGBT rectier With PWM tech

INPUT

Ac-Voltage 3Ph 380/400/415VAC +N+G (L-N: 220/230/240VAC)

Tolerance -45% Nominal + 25%

THD 3%

Frequency 50Hz (60) auto-detect (40-72Hz range)

Input P.F. >0.99
Power Walk-in Yes

DC TO AC INVERSION

IGBT Inverter Transformer-less

Output P.F. 0.9

Voltage 3Ph 380/400/415VAC +N+G (L-N: 220/230/240VAC) + 1%
Overload 115%: keep working, 125%, 10mins

THDi 2%
Frequency 50Hz (60)

Unbalanced load 100%
Crestor factor 3:01

BYPASS

Static bypass Yes

Voltage 3Ph 380/400/415VAC +N+G (L-N: 220/230/240VAC) + 15%

MAINTENANCE BYPASS

SWMB Yes Yes
Battery congure Option

Charge ABM or 3-stage charge control

Battery type VRLA or Gel
Backup time Depend on capacity, discharge depth

Quantity 32-40 cells, default 36 36-40 cells, default 40

Recharge time 8 hours up to 90%

COMMUNICATION SLOT

Slot RS 232, Mini-slot
Accessory Mini-slot SNMP/Web Card, Mini-slot Modbus/Ethernet card, Mini-slot AS400 card

OPERATION CONDITION

Temperature 0 ~ 40°C

Storage - 25 ~ 55°C

Humidity 5 ~ 95% (non condensing)

Altitude No degrade power under 1000m

Noise (dB) 55 62 65 70 73

STANDARDS

EMC 61000-4
EMI EN5550022/EN55024
Quality
ISO9001-2008

Certicate CE

KVA 15 20 30 40 60 80 100 120 160 200 300 400
Physical Size
500*710*960/1230/1500 600*800*1876 1600*820*1880

UPS Weight 72 91 120 202 245 283 311 457 860 970

UPS with battery 272 376 490 External battery design
UPS with transformer 220
245 328 532 575 660 720 Transformer-less

www.poweronenertech.com 44

POWER PROTECTION 6. HF ONLINE UPS RT - 1:1

6.1.HP 116CR 1-10KVA Powerguard HP116CR Series 1-10KVA (1 Ph in/1Ph out
& 3 Ph in/ 1 Ph out)

Overview: friendly.
Powerguard HP116CR Series • Pure high frequency online UPS, with
High Frequency Online Rack Mount UPS voltage adjustment circuit, provide reliable
1-10KVA (1 Ph in/1Ph out & 3 Ph in/ 1 Ph out) power protection in the bad operation
Nominal voltage : 208/220/230/240VAC environment.
Nominal frequency: 50/60Hz • Comprehensive electric isolate and bypass
Output Power factor : 0.7/0.8 (Optional) protection.
• Input power factor correction, reduce the
The more flexible and reliable power harm of harmonic to the power grid,
protection convenient to match small generators.
Power Guard HP116CR series rack mount • Automatic alarm, self test function.
UPS is pure online UPS, the capacity from • Wide input voltage range.
1kva to 10 kva. Compared to line interactive input neutral and live wire detection and data
or offline UPS, online can provide the best protect function.
power environment for the load and it is the • When main power failure, the UPS going to
best UPS structure considering from the DC start, Convenient and reliable; when
output range of voltage stabilize, frequency m a i n p o w e r r e c o v e r, U P S r e s t a r t
range, input noise filter, and the zero transfer automatically.
time from utility model to battery mode. • N+X Parallel Redundancy and Capacity
expansion for 6K-10K.
Feature:
• Large blue LCD display interface, user-

www.poweronenertech.com 45

Technical Specifications

Model HP116CR 1-10KVA

1KR/1KR-XL 2KR/2KR-XL 3KR/3KR-XL 6KR/6KR-XL 10KR/10KR-XL 10KR-XL

Capacity 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW 6KVA/4.2KW 10KVA/7KW 10KVA/7KW
Nominal Voltage
220/230/240VAC

Frequency 50/60 Hz

INPUT

Voltage Range 115~295VAC (±3VAC) 176~297VAC (±3VAC) 304~478VAC (±3VAC)

Frequency Range 50HZ: (46~54HZ) ; 60HZ : (56HZ~64HZ)

Power Factor >0.98

OUTPUT

Voltage Precision 220/230/240X (1±2%) VAC

Frequency Precision 50/60Hz ±0.05 Hz

Power Factor 0.7/0.8 (Optional) Standard 0.7

Voltage Distortion Linear load<3% Non-linear load<6%

Overload Capacity 110%~150% for 30sec; > 150% for 200ms 105%~130% for 10min; >130% for 1 min

Current Crest Ratio 3:1

Transfer Time 0ms (AC " DC)

BATTERY

DC Voltage 36VDC 96VDC 240VDC

Recharge Time (5 hours to 90% (optional : 2KR/3KR standard model battery inside the UPS)

Recharge Current 1A 81 8 1A 8A 2.0A/4.2A/5.6A (Option)
PANEL DISPLAY

LCD Display input and output Voltage, Frequency, Battery voltage, Battery capacity and the percentage of load

COMMUNICATION

Communications Interface RS232, SNMP card (Option), USB port (Option)

WORKING ENVIRONMENT

Temperature 0~40 °C

Humidity 0~95% (Non-condensing)

Storage Temperature -25 °C~55 °C

Elevation <1500m

Noise Level (1m) <45dB <50db

PHYSICAL CHARACTERISTIC

Weight N.W. 16.5 9 26 11.5 26 12.5 18.5 20.5 22 24 25.5
(KG) G.W. 27 28.5
18.5 11.5 28 14.5 28 15 21.5 23.5 25

Dimensions : \ 447x450x89 447x600x130 447x450x89 447x600x130 447x450x89 447x600x177
(WxDxH)mm 2U
3U 2U 3U 2U 3U 4U

STANDARD Conrm to GB/IEC regulation

EMC GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5
GB 4943
SAFETY

www.poweronenertech.com 46

POWER PROTECTION PH 119C RT II SERIES 1KRT-3KRT 1:1 PF 0.9

6.2.PH 119CRT II SERIES Overview:
1-3KRT Optional Sockets
Rack -tower Convertible
Battery Cabinets (optional )
Multifunctional Brackets
Easy For Maintenance - Hot Swappable
Battery

Feature:
• Cold Start
• Efficiency up to 90%
• Emergency Power Off
• Matching Battery Pack
• Hot-Swappable Battery
• Optional Powerful Charger
• Rack/Tower Convertible Design
• True Online Double Conversion
• High Output Power Factor at 0.9PF
• Frequency Converter Mode ls Settable
• Support Economic(ECO) Operation Mode
• Estimated Remaining Time displayed on

the LCD
• Smart SNMP works with either USB or RS-

232 together
• Power Shedding May Turn Off Uncritical

Load in Battery Backup
• Patented Mimic LCD Display May be

Rotated by Simply Pushing Front Button
• Comprehensive display allows easy

monitoring and access of UPS status

www.poweronenertech.com 47

Technical Specifications

MODEL PH119C2 - 1KRTS PH119C2- 1.5KRTS PH119C2- 2KRTS PH119C2-3KRTS
Capacity(VA/Watts) 1000 / 900 1500 / 1350 2000 / 1800 3000 / 2700
INPUT
Nominal voltage 200/208/220/230/240Vac
Operating voltage range
Operating frequency range 110-290Vac
Power factor 45~65Hz(auto-detect)

Bypass voltage range ≥ 0.98

Max.voltage: +15%(optional +5%, +10%, +25%)
Min. voltage: - 45% (optional -15%, - 20%, - 30%)

Frequency protection range: ± 10%

Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power factor 0.9
Voltage regulation
Frequency Utility Mode ± 2%
50Hz or 60Hz(Synchronized to Mains)
Battery Mode
Crest factor 50/60Hz ± 0.02Hz
3:1

THDv ≤ 3% with linear load
≤ 5% with non linear load

AC Mode(full load) Up to 90%
Efficiency Battery Mode(full load) > 85%
> 94%
ECO Mode(full load)
BATTERY

Battery Type 12V/9AH 12V/9AH 12V/9AH 12V/9AH

Numbers 2 34 6
Standard Typical Recharge Time 4 hours recover to 90% capacity
Model
1.4 A
Charging Current(max.)

Charging Voltage 27.4Vdc ± 1% 41.0Vdc ± 1% 54.7Vdc ± 1% 82.1Vdc ± 1%

Battery Numbers 6A/12A(double board) Depending on the capacity of external batteries 6A/12A(double board)
Long-run Charging Current(max.) 27.4Vdc ± 1% 7A/14A(double board) 6A/12A(double board) 82.1Vdc ± 1%
Model
41.0Vdc ± 1% 54.7Vdc ± 1%
Charging Voltage
SYSTEM FEATURES Utility to Battery: 0ms; Utility to bypass< 4ms
Transfer time

AC Mode Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely

Overload Bat. Mode Load <100%~150%: 30S; Load > 150%: 300ms then shut down UPS completely

Bypass Mode Load > 130%: 60S then shut down output

Audible & Visual alarms Line Failure, Battery Low, Overload, System Fault

Status LED & LCD display Load/Battery/lnput/Output/Operating Mode Information

ENVIRONMENTAL

Dimension(W X H X D)mm 440 X 86.5 X 430 440 X 86.5 X 430 440 X 86.5 X 572 440 X 86.5 X 696

Weight (Kg) 15.1 18.1 22.2 25.5

Input Connection IEC320 C14-10A IEC320 C14-10A IEC320 C20-16A IEC320 C20-16A

Output Connection IEC320 C13-10A X 6 IEC320 C13-10A X 6 IEC320 C13-10A X 6 IEC320 C13-10A X 6 & C19-16A X 6

Communication Interface Smart RS232/USB Port/RJ45/SNMP Card (independent to RS232)

Operating temperature 0°C ~ 40°C

Storage temperature - 25°C ~ + 55°C

Humidity 0 ~ 95% (non condensing)
Altitude < 1500m. (derating while > 1500m)

Noise < 50dB (at 1 meter)
BATTERY BANK PBB 129 RT2
Model

Battery type& Max.quantity 9Ah X 4 9Ah X 6 9Ah X 8 9Ah X 12
PHYSICAL OF BATTERY BANK 440 X 86.5 X 430 440 X 86.5 X 430 440 X 86.5 X 572 440 X 86.5 X 696
Unit Dimensions DXWXH (mm)

Net weight (kg) 12 15 22 32

www.poweronenertech.com 48

POWER PROTECTION PH 119C 6KRTS 10KRTS PH119C-6KRTXL-10KRTXL
1:1 Phase
6.3.PH 119C 6 - 10KRTXL

Overview: • Input current harmonic: 3%
The LED Panel Can Be Rotated • Non Transfer Time of output
This Series Has Matching Battery Cabinets • Self-testing when UPS startup
(optional) • Options: SNMP card/Relay card
Rack Tower Convertible • Communication port: RS232, USB
• Input over/under-voltage protection
Feature: • Wide input voltage range: 120~276Vac
• DC start • Optimization battery group, the quantity
• ECO function
• PFC technology of battery: 16/18/20 pieces (optional)
• Automatic bypass • Charging/Rectier/lnverter fully digital
• Full digital control (DSP)
• Output power factor: 0.9 control technology
• Online-Double conversion • Wide input frequency range: 45-5Hz/

54-66Hz ±0.5Hz

www.poweronenertech.com 49

Technical Specifications

MODEL PH119C-6KRTS PH119C-10KRTS
Capacity(VA/Watts) 6k / 5.4k 10k / 9k
INPUT
Nominal voltage 220/230/240Vac(L+N+PE)
Operating voltage range
Operating frequency range 120Vac~276Vac
Power factor
45~55Hz/54~66Hz ± 5Hz
Bypass voltage range ≥ 0.99

220V: +25%(optional +10%,+15%,+20%)
230: +20% (optional +10%,+15%)
240: +15% (optional +10%)

Min.voltage: - 45% (optional -20%, -30%)

ECO range Same as the bypass
Harmonic distortion (THDi) ≤ 3%(100% linear load)
Generator input
OUTPUT Support
Output voltage
Power factor 220 / 230 / 240Vac
Voltage regulation 0.9
Frequency Line Mode
± 2%
Bat. Mode ± 1% / ± 2% / ± 4% / ± 5% / ± 10% of the rated frequency(optiona|)
Crest factor
50/60 (± 0.1)Hz
Harmonic distortion (THDv) 3:1

Waveform ≤ 2% with linear load
≤ 5% with non linear load
Efciency
BATTERY Pure Sinewave
Battery voltage > 93.5%

Optional Voltage: ± 96/108/120Vdc

Typical recharge time 6~8 hours (to 90% of full capacity)
Charge Current Maximum current 6A; charge current can be set according to battery capacity installed.
SYSTEM FEATURES
Transfer time Utility to Battery : 0ms; Utility to bypass: 0ms

Line Mode Load ≤ 110%: last 60min, ≤125%: last 10min, ≤ 150%: Iast 1S, > 150% turn to bypass mode
Overload
40A(Input breaker) 60A(Input breaker)
Bypass Mode
Short Circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Low battery voltage
Self - diagnostics Alarm and Switch off
EPO (optional) Upon Power On and Software Control
Battery
Noise Suppression Shut down UPS immediately
Audible & Visual alarms
Status LED & LCD display Advanced Battery Management
Complies with EN62040-2
Reading on the LCD display
Line Failure, Battery Low, Overload, System Fault

Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault

Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage,
Inner Temperature & Remaining Battery Backup Time

Communication interface USB, RS232, Parallel Port, SNMP card / Relay card (optional)
ENVIRONMENTAL
Operating temperature 0°C ~ 40°C
Storage temperature - 25°C ~ 55°C
Humidity range 0 ~ 95% (non condensing)
Altitude
Noise level < 1500m
PHYSICAL < 55dB
Dimension W X H X D (mm)
Net weight (kg) 443 X 131 X580(3U)
STANDARDS 23 25
Safety
IEC/EN62040 - 1, IEC/EN60950 - 1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,

www.poweronenertech.com IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

50

POWER PROTECTION PH 119 C RT SERIES RACK TOWER CONVERTIBLE
PH119C-1KRTS- 3KRTS 1:1 Phase(PF0.9)
6.4.PH 119C 1KRTS-3KRTS

Overview: • Extended runtime with up to four
The Series Has Extended Battery Packs (EBPs) per UPS.
Two Directions LCD Display
Rack Tower Convertible • Easy maintenance design with hot
Multi-functional Bracket swappable battery pack from the font.
Matching Battery Cabinets (optional)
Hot-swappable Battery - Easy For • Emergency shutdown control through the
Maintenance Emergency Power-o (EPO) port.

Feature: • With RT LCD design, just press the function
• Rack and tower installation convertible. button can meet visual angle requirement.
• Versatile LCD display with setting function.
• Selectable High efciency mode of • Shedding function may turn off uncritical
load in battery backup to make longer
operation. backup time for critical load.
• High power density. Output power factor
• Standard communication options : RS 232,
up to 0.9. communication ,USB communication port
• Cold start function to startup the UPS and relay output contacts or SNMP card.

without utility. • Three segment charging mode to increase
battery service life, optimize recharge time.
Standard communication options: one
RS-232 communication port, one USB
Power

www.poweronenertech.com 51

Technical Specifications

MODEL PH119C-1KRTS PH119C-2KRTS PH119C-3KRTS
Capacity(VA/Watts) 1000 / 900 2000 / 1800 3000 / 2700
INPUT
Nominal voltage 4.9A 220 / 230 / 240Vac 14.2A
Operating voltage range 200 ~ 290Vac
Operating frequency range
Power factor 50Hz / 60Hz ± 10%
Max. input current ≥ 0.99
OUTPUT 9.5A
Output voltage
Output frequency 200/208/220/230/240Vac ± 1%
Crest factor Synchronized with the utility on AC mode; 50Hz/60Hz ± 0.2 on battery mode
Harmonic distortion (THDv)
3:1
Efciency ≤ 3% (linear load)

BATTERY >89%
DC voltage >94% (high efciency mode)
Battery type & number
Backup time 36Vdc 72Vdc 72Vdc
Typical recharge time 12V/7Ah/9Ah X 3 12V/7Ah/9Ah X 6 12V/9Ah X 6
Charge Current Estimated remaining time displayed on the LCD
SYSTEM FEATURES 1.0A 5 hours (to 90% of full capacity) 1.0A

Transfer time 1.0A

Overload Capability 1. 0ms (Mains 1 Battery)
LCD indication 2. <4ms (Mains 1 Bypass)

Audible alarm 30s at 100% ~ 150% ; 300ms at>150%

Load/Battery/lnput/Output/Operating Mode Information

1. Sounding every 4 seconds (Battery Mode)
2. Sounding every second (Low Battery)

3. Sounding twice every second (Overload)
4. Continuously Sounding (Fault)

Communication interface RS232, USB, SNMP (optional)
ENVIRONMENTAL
Operating temperature 0°C ~ 40°C
Humidity range 0 ~ 95% (non condensing)
Altitude
Noise level < 1500m
PHYSICAL < 45dB
Dimension D X W X H (mm)
Net weight (kg) 430 X 440 X 86.5 690 X 440 X 86.5
STANDARDS 13
24.6 25.5

Safety IEC/EN62040 - 1, IEC/EN60950 - 1

EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

www.poweronenertech.com 52

POWER PROTECTION 7. HF ONLINE UPS RT - 3:1

7.1.PH 319C 6KRTS-10KRTS PH 319C RT SERIES PH319C-6KRTS-10KRTS(XL)
3:1 Phase( PF 0.9 )

Overview:
Rack Tower Convertible
The LED Panel Can Be Rotated
This Series Has Matching Battery Cabinets
(optional)

Feature: •Wide input frequency range:40~70Hz±0.5Hz
• DC start • Communication port : RS232, dry contact,
• ECO function
• PFC technology RS485×2
• Automatic bypass • Charging/Rectier/Inverter fully digital
• Full digital control (DSP)
• Output power factor: 0.9 control technology
• Online-Double conversion • Wide input voltage range: 208~478Vac or
• Non Transfer Time of output
• Input current harmonic: 5% 120VAC-276VAC
• Self-testing when UPS startup • Options: SNMP card/Centralized monitoring
• Input over/under-voltage protection
card/ Parallel port module
• Optimization battery group, the quantity of

battery: 16/18/20 pieces (optional)

www.poweronenertech.com 53

Technical Specifications

MODEL PH319C-6KRTS PH319C-10KRTS
Capacity(VA/Watts) 6k / 5.4k 10k / 9k
INPUT
Nominal voltage 380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE)
Operating voltage range 208~478Vac or 120Vac~276Vac
Operating frequency range
Power factor 50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)

Bypass voltage range ≥ 0.99

Bypass frequency range Max.voltage: 220V: +25%(optional +10%,+15%,+20%)
ECO range 230V: +20% (optional +10%,+15%)
Harmonic distortion (THDi) 240V: +15% (optional +10%)
Generator input
OUTPUT Min.voltage: - 45% (optional -20%, -30%)
Output voltage
Power factor Frequency protection range: ± 10%
Voltage regulation Same as the bypass
Frequency Line Mode
≤ 5%(100% linear load)
Bat. Mode
Crest factor Support

220 / 230 / 240Vac
0.9

± 1%
± 1% / ± 2% / ± 4% / ± 5% / ± 10% of the rated frequency(optiona|)

50/60 (± 0.1)Hz

3:1

Harmonic distortion (THD) ≤ 2% with linear load
≤ 5% with non linear load

Efciency > 93.5%
BATTERY ± 96/108/120Vdc (optional)
Battery voltage

Backup time Long run unit depends on the capacity of external batteries
Typical recharge time Estimated remaining time displayed on the LCD

6~8 hours (to 90% of full capacity)

Charge Current Maximum current 10A; charge current can be set according to battery capacity installed.
SYSTEM FEATURES
Transfer time Mains to Battery : 0ms; Mains to bypass: 0ms

Line Mode Load ≤ 110%: last 60min, ≤125%: last 10min, ≤ 150%: Iast 1min, > 150% turn to bypass mode
Overload
40A(Input breaker) 60A(Input breaker)
Bypass Mode
Hold Whole System
Short Circuit
Overheat Line Mode: Turn to Bypass; Backup Mode: Shut down UPS immediately
Low battery voltage
Self - diagnostics Alarm and Switch off
Battery
Audible & Visual alarms Upon Power On and Software Control

Status LED & LCD display Advanced Battery Management

Line Failure, Battery Low, Overload, System Fault

Line Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault

Reading on the LCD display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage,
Inner Temperature & Remaining Battery Backup Time
Communication interface RS232,USB,SNMP card(optional), Relay card (optional)
ENVIRONMENTAL
Operating temperature 0°C ~ 40°C

Storage temperature - 25°C ~ 55°C

Humidity range 0 ~ 95% (non condensing)

Altitude < 1500m

Noise level < 55dB
PHYSICAL 580 X 443 X 131(3U)

Dimension D X W X H (mm)

Net weight (kg) 23 25
STANDARDS IEC/EN62040 - 1, IEC/EN60950 - 1
Safety

EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
BATTERY BANK PBB12920RT
Model

Battery type& Max.quantity 7Ah X 20 9Ah X 20
PHYSICAL 0F BATTERY BANK
Dimensions DXWXH (mm) 720 X 443 X 131(3U)

Net weight (kg) 30(3:1) / 19(1:1) 31(3:1) / 20(1:1)

www.poweronenertech.com 54

POWER PROTECTION 8. HF ONLINE UPS TOWER

8.1.PH 119C 1-3KT PF-0.9 PHC 119C Series PH119C 1KT-3KT 1:1 Phase(PF0.9)

Overview: • Output power factor up to 0.9.
This series has • Versatile LCD display with setting function.
1.EPO port • Selectable high efciency mode of
2.Intelligent slot for SNMP card, drycontact
cart etc. operation.
3.External battery cabinet connector • Three segment charging mode to increase
4.Output slots including two segments
5.Large current output slot battery life, optimize recharge time.
6.Input slot • Extended runtime with up to four extended
7.RJ45 surge suppress port
8.RS232 port battery modules (EBPs) per UPS.
9.USB port • Emergency shutdown control through the
10.Matching Battery Cabinets (Optional)
remote emergency power-off (EPO) port.
Feature: • Power shedding function may turn off
• Cold start.
• High power density. uncritical load in battery backup to make
longer backup time for critical load.
• Standard communication options: RS-232
communication port, USB communication
port, and relay output contacts or SNMP
card.