We are concerned about people’s lives.
Fire Alarm Systems
For reliability, flexibility and common-sense pricing.
Conventional Detectors
AHR-871 AH-9920
QA31 Mechanical Rate of Rise Mechanical Fixed AH-0822
Single Station Smoke Detector Heat Detector Temperature Heat Detector Gas Detector
Characteristics Characteristics Characteristics Characteristics
• The QA31 features advanced • Heat-sensing diaphragm • This detector operates • The AH-0822 features ad-
photoelectric technology can operate for unlimited on the temperature vanced technology, high
for precise detection. When number of times and is not differential sensing accurate detection, low power-
smoke is detected or the affected by room tempera- principle, with a UL consumption and fast reac-
manual test button is pressed, ture. The conducting parts approved sensor tion time. It can detect natural
the buzzer sounds and LED use gold coating to avoid making mechanical gas and propane gas. Built-in
flash. oxidation. contact. buzzer and LED indicator alert
• Low-Battery Warning: Unit • Uses alloy air equalizer to • This detector is suit- by sounding and flashing.
beeps and LED flash intermit- avoid humidity and stabi- able for locations with
tently to indicate battery needs lize the ventilation func- high temperatures • Sounding and flashing in alarm
replacing. tion. Alloy itself has many temperature differen- status; the green LED is lit dur-
ing monitoring and the red LED
• 9VDC battery provided. micro-holes that can expel tials where there is flashes in alarm status.
constant use of heat.
non-fire heat to avoid false
• Optional relay output : COM. alarms. • The unit is completely
NO. NC. sealed; its function • 12VDC or 24VDC input.
• Optional series connection • The unit is completely is not affected by • Dual output relays: Opto-iso-
sealed; its function is not
wiring can co-activate up to affected by humidity, dust humidity, dust or lator output and Remote LED
15 detectors. or insects. insects. output
AH-0621 AH-8321 AH-9616
Photoelectric Photoelectric Combination
Smoke Detector Smoke Detector Heat Detector
Characteristics Characteristics Characteristics
• Contacts material is highly • Electronic circuit are mainly • Multi-purpose Design: this
acid-resistant and rust- use ONECHIP HYBRID IC detector is designed to ensure
resistant. and SMT technology, low the detection ability for tem-
• Twin-color LED display profile design, low power perature change during pre-
enables viewer to easily consumption, high precision fire period. Combination of
identify the current status and stability. two different heat detection
of detector. • This item has passed EMC functions (rate of rise and fixed
• Detector is made of high test with highest level re- temperature) makes the prod-
uct safer and more reliable.
endurance, solid and col- quirements, so it will not
orfast Fire-proof plastic. easily be affected by electro- • With accumulated water dis-
• The standard detector is magnetic field, thunder strike charger to eliminate leakage of
water from the distributing pipe
and other interference souce
2-wire or 3-wire. For 4-wire from the installation site. and ceiling.
type just add one relay
output module. Simple and • Regularly measures smoke • Heated sensing diaphragm
easy module placement particle level from smoke can operate consecutively for
enables wider application chamber, and with double- unlimited times, not effected
and flexible stock control. check feature to avoid false by temperature, especially the
• Non-loosening screws alarm. conducting part use gold coat-
ing to avoid oxidation.
on base terminal for easy • Every detector has used
installation. static process to eliminate • Use ally air equalizer to avoid
• Detector has passed strict dust inside the chamber humidity and stable the venti-
late function.
before shipping. The special
EMC test, which greatly design of smoke chamber
eliminates false alarms could effectively prevent the • This detector has passed strict
caused by interference access for external light and quality control by automatic
from nearby sources. dust. test.
Conventional Control Panel
LED Description
Characteristics • FIRE : Indicates fire status
• Model range from 12 to 100 zones. • Power : Indicates unit is in
• AC power supply has EMI (Electromag- normal status
netic Interference). AH-02124 • Short C. : Indicates short-
• Each zone has a separate disable func- circuit
tion. Annunciator • Discon. : Indicates discon-
• Double sets of sounder contacts. nection
• Automatic telephone dialer feature. • S.T. : Controls H1 & H2 for
• Long-term or temporary silencing feature. activation, light on means
• Protection against voltage spikes up to inactive
2.5KV. • Bell : Activates unit’s sounder
• Microprocessor-base design. and external bell, light on
means inactive
detection.
4 zone 8 zone 32 zone • Sounder short circuit or disconnection • Reset : Turns system back to
• Fire Alarm NO, NC, COM and Fault NO, initial status
AHC-871 NC, COM output contact points.
Fire Alarm Control Panel • Fire Relay Output contacts and Fault
12 zones up to 100 zones Relay Output contacts.
• Switch membrane provides longer service
and is waterproof, dust resistant and easy AH-00212
to clean. Fire Alarm Control Panel, 1 zone up to 10 zones
Components
CE listed
EN listed
AH-0218 AH-9718 CNS AH-9719 AH-0217
Fire Alarm Bell 6" 506e/01 Fire Alarm Bell 4" Fire Indicating Lamp Manual Call Point 506e/01
Features Features Features Features
• High efficiency low current consumption • Motor energized, • Uses white • Available in flush or surface mounted
on 24VDC motorized bells. low power con- bulb (or low models.
• Terminals will accept 2.5mm cables. sumption (28mA), current LED) • Plastic film on glass.
long operating
• Simple installation via multi-fixing base life. and installed
plate for all types of location. inside the red • Test key inserted from bottom.
• Fitted with two series diodes for fault • Bell shell is made lamp cover. • Suitable for the majority of conven-
of steel plate, so
monitoring. it will sound loud • When lit, it is tional fire alarm system.
• Option of customized discs printed with and clear. clear visible
company name and logo. • 220VAC bells are within 10 • Choice of red, yellow, blue or green
finish also available for custom-
• 12VDC bells are also available. also available. meters. made.
506e/01 506e/01
AH-9717 AH-9717 AH-03127-BS AH-03127-S AH-91213 AH-01313
Manual with base Electronic Sounder Electronic Sounder Remote Indicating Remote Indicating
Call Point Manual Call Point and Beacon Lamp Lamp
Features Characteristics Characteristics
• Emergency press alarm, immediately • 32 signal tones selectable by Dip • Larger indicating lamp.(Model.AH-91213)
activates fire alarm signal. switch.
• Built-in flash light, higher illumination
• Indicator light above fire alarm push-but- • High sound output with low current and longer operating life. (Model.AH-
ton confirms the alarm signal transfer. consumption. 91213)
• There are a phone jack and reset button • High efficiency lens for maximum • Individual reset switch. (Model.AH-
behind the cover cap. light output. 91213)
• Type I is simultaneous dual loop, Type II • Volume Control as standard. • Low current consumption. (Model.AH-
is simultaneous dual signal transfer. 01313)
• Two sets of IN and OUT terminals,
• Optional base is available. easy for installation. • Parallel type wiring.
Addressable Detectors and Control Panel
QA01 EN54 pending
Addressable Photoelectric
Smoke Detector
QA16
Addressable Fire Alarm
Control Panel
QA19
EN54 pending EN54 pending Addressable Characteristics
QA05 QA06 Manual Call Point
Addressable Combination Addressable • Large LCD screen (40 x 15
Smoke and Heat Detector Heat Detector lines) allows more events to
Features be displayed on the same
screen.
Characteristics (QA01, QA05, QA06) • Emergency press
alarm, immediately • Loop device can be set up to
• 2-wire base connection without polarity sensitivity makes activates fire alarm be temporarily isolated.
installation much easier. signal.
• Latching function helps to identify alarm device clearly and • There are a phone • Optional thermal printer that
can printout complete panel
quickly. jack and reset but- status.
• Address coding by dip switch makes the job easier. ton behind the cover
• Magnetic test feature makes maintenance easy and simple. cap. • Individual loop module test
feature to save time on panel
• Non-loosening screws on base terminal for easy installa- • Optional base is test.
tion. available.
• Detector is made of high endurance, solid and colorfast • On-board Self-test feature for
simulating alarm output.
Fire-proof plastic.
• Detector has passed strict EMC test, which greatly elimi- • Easy system programming
nates false alarms caused by interference from nearby through PC to panel.
sources.
• Dual LEDs for 360-degree visibility. • Events log can store up to
1023 events.
Addressable Module Series
QA17-A
QA17-H QA17-K
QA17-B
Characteristics
• Low power consumption in monitoring mode, high stability. all kinds of systems. (fire alarm, smoke evacuation, sprin-
• Easy installation, either single module installation or several kler, foam , winding door...etc.)
modules installed on a special mounting bar. Implanted type • Output module QA17-A can directly connect with power
gang box is available to suit the decoration design. source. The output voltage from N.O. & N.C. will be the
• The Module is designed with separate input and output contacts same as input voltage.
to decrease the difficulty of moving external wiring. • Monitor module QA17-K is designed to monitor security
• Control Module QA17-B is designed to control input & output for condition, such as water supply, pump action ...etc.
Calderon Bldg., 827 EDSA, South Triangle, Quezon City
Manila: ( 410-1155, 929-9911 • Cebu: ( 346-5413 to 14 • Davao: ( 282-8606 • 282-8694
www.multi-linegroup.com • [email protected]