Life Safety and Emergency
Communications Systems
Intelligent Fire Alarm Control Panels
NFS2-3030 NFS2-640(E) NFS-320 SFP-5UDC / SFP-10UDC
Intelligent Addressable Intelligent Addressable Intelligent Addressable Conventional Fire Alarm Control Panel
Fire Alarm System Fire Alarm System Fire Alarm System 5-zone, 10-zone
Features Features Features Features
• Up to 159 detectors • Up to 159 detectors and • Up to 159 detectors and • A Fire Alarm Control Panel that
and 159 modules 159 modules per SLC; 159 modules per SLC; provide reliable fire signaling
per SLC; 318 318 devices per loop/636 318 devices maximum protection for small to medium-
devices per per FACP or network • Standard 80-character sized commercial, industrial,
loop/3,180 per node display and institutional buildings
FACP or network • Standard 80-character • High-speed network for • Outputs include four NACs
node display, 640-character up to 200 nodes (Notification Appliance
• Large 16 line, 640 large display (NCA-2), or • 6.0 A power supply with Circuits), three programmable
character LCD display-less (a node on a four Class A/B built-in Form-C relays (factory
backlit display or network) Notification Appliance programmed for Alarm,
use display-less as • High-speed network for Circuits (NAC) Trouble, and Supervisory) and
a network node up to 200 nodes • Full QWERTY keypad 24 VDC special application
• High-speed network • 6.0 A switch mode power • Battery charger supports resettable and nonresettable
for up to 200 nodes supply with four Class 18 – 200 AH batteries power outputs
A/B built-in Notification
Appliance Circuits (NAC)
LCD2-80
DVC-EM ONYX FirstVision™ Terminal Mode/ACS eVance™
Digital Voice Command Interactive Firefighters’ Display ModeAnnunciator Service Manager
Features Features Features Features
• Programmable • 22” LCD touch- • 80-character backlit • Keep track of annual
• Up to 32 minutes of screen Liquid Crystal Display (20 inspection due dates
standard quality or 4 • Interfaces with characters x 4 lines) for all fire systems
minutes of high quality ONYX® Series • Display mimics panel or NCA: • Offer additional value
digital audio storage of panels or - Event message to facility owners and
user-selected/created NOTI•FIRE•NET - 20 characters for point managers
messages and tones (version 5.0 or label • Be proactive
• 4-channel analog audio higher) - 12 characters for by receiving
supported • Compatible with extended label automatic alerts
• Up to 1000 audio standard and - Time, date and point and notifications via
sequences High Speed address Service Manager
• Message prioritization NOTI•FIRE•NET™ • Control switches for System • The customer’s
• Firefighters’ Telephone • Supports multiple Acknowledge, Signal Silence equipment, service
Communications gateways for large Drill and System Reset history and diagnostic
• Local paging microphone networks and • LEDS for general off-normal information is
option campuses events with UL 864 9th available in real time
Edition Panels
Quezon City: ( 410-1155, 929-9911 • Cebu: ( 346-5413 • Davao: ( 282-8606 • [email protected] • www.multi-linegroup.com
Fire Alarm Devices
882 Photoelectronic Detector FSP-851(A) in B210LP(A) Base
885 Heat Detector
FSP-851(A) Series FAPT-851 LPX-751
800 Series Intelligent Plug-In Acclimate Plus™ Very Intelligent
Multi-Sensor
Photoelectric
Early Warning (VIEW®)
Low-Profile Plug-in Smoke Detectors with Low-Profile LASER Smoke Detector
Smoke/Heat Detectors FlashScan® Intelligent Detector
Features Features Features Features
• 2-wire conventional • photoelectric detector’s • Automatically adjusts sensitivity • Very Intelligent Early
profile plug-in detectors unique optical sensing levels without the need for operator Warning (VIEW®)
aimed to meet the chamber is engineered intervention or programming, smoke detection
performance criteria to sense smoke sensitivity increases with heat • Advanced laser light
designated by UL produced by a wide • Microprocessor-based, combination source and patented
• Operating Temperature range of combustion photo and thermal technology optical design
Range: 0~38°C (32°F sources. Dual • Addressable-analog communication • Sleek low-profile
to 100°F) for Heat, electronic thermistors • Rotary, decimal addressing (1 – 99 housing (1.66”/42.164
0~49°C (32°F to 120°F) add 135°F (57°C) on current classic systems, 1 – 159 mm height)
for Photoelectronic fixed-temperature on ONYX® Series FlashScan® • NOTIFIER Analog
• Operating Humidity thermal sensing on the systems, 1 – 99 on the AFC-600) Addressable
Range: 10% to 93% FSP-851T(A) • Addresses can be viewed and communications
Relative Humidity, Non- • Sleek, low-profile changed without the need for protocol provides
condensing design electronic programmers extremely reliable
• interruptionSensitivity: • Addressable-analog • Dual bi-color LED design provides operation proven in
63°C (145.4°F) Fixed communication 360° viewing angle millions of worldwide
(Heat only) • Stable communication • LEDs lock red when in Alarm. In detector installations
• Operating Voltage: technique with noise FlashScan®, LEDs flash green in • Sensitivity to 0.03%/
8.5~30 VDC for Heat, immunity Standby for normal condition foot
8.5~35 VDC for • Two-wire SLC • Built-in tamper-resistant feature
Photoelectronic connection • Sealed against back pressure
Kobishi MBA-6 FSM500K NBG-12 Series EXITPOINT
Fire Alarm Bells Manual Call Point Manual Pull Stations Directional Sounder
Features Features Features Features
• DC 12.1mA • CSIRO Approved • non-coded manual pull • Four field-selectable routing
• FWR 12.4mA • Two wire connection for stations which provide a Fire evacuation patterns
• UL 83dB easy installation Alarm Control Panel (FACP) • Ideal in unfamiliar
• Typical 87dB • Suitable for flush mounting with a single alarm initiating surroundings or poor visibility
• Can used at outdoor or surface mounting input signal • Works in open areas,
• Very low current • Simple rotary decade • This series includes both corridors or stairs
consumption only setting single-action and dual-action • Reduces evacuation times by
12.1mA at 24VDC • Integral LED controlled models equipped with either as much as 75%
from panel a hex or key lock / reset
Quezon City: ( 410-1155, 929-9911 • Cebu: ( 346-5413 • Davao: ( 282-8606 • [email protected] • www.multi-linegroup.com
Fire Alarm Devices
FMM-1(A) (Type H)
800 Series 900 Series
SpectrAlert SpectrAlert 800 900 Series
Indoor Selectable-Output Speaker Advance Series D4240 Linear Heat Detector
Strobes and Dual Voltage Features
Evacuation Speakers Indoor Selectable-Output 4-Wire Photoelectric
Horns, Strobes Duct Smoke Detector • Multiple alarm
Features and Horn Strobes for Wall temperature ratings
Applications Features available for both
• Plug-in design and protective
cover reduce ground faults • Photoelectric, integrated digital and analogue
• Universal mounting plate with Features low-flow technology type
an onboard shorting spring • Automatic selection of 12- • Air velocity rating from • Maximum zone length
tests wiring continuity before or 24-volt operation at 15 100 ft/min to 4,000 ft/ (Digital) - 1000 meters
installation and 15/75 candela min (0.5 m.s to 20.32 m/ • Maximum zone length
• Field selectable candela • Field-selectable candela sec) (Analogue) – 600
settings settings on wall units: 15, • Versatile mounting meters
• Automatic selection of 12- or 15/75, 30, 75, 95, 110, options square or • Resettable
24-volt operation at 15 and 115, 135, 150, 177, and rectangular configuration temperature up
15/75 candela 185 • Broad ranges for to 120°C (248°F)
• Rotary switch simplifies field • Rotary switch for horn operating temperature (Analogue)
selection of speaker voltage tone and three volume (-4°F to 158°F) and • Compatible with
(25 and 70.7 Vrms) and selections humidity (0% to 90% any conventional or
power settings (¼, ½, 1 and 2 • Universal mounting plate non-condensing) intelligent fire alarm
watts) for wall units panel
Fire Alarm Modules
FRM-1(A)
Control and Relay Module
Features
• Addressable Relay Module provides the system with a dry-contact output for activating
a variety of auxiliary devices, such as fans, dampers, control equipment, etc.
• Allows the dry contact to be activated, either manually or through panel programming,
on a select basis
FMM-1(A)
Monitor Module with FlashScan®
Features
• Monitor modules supervise a circuit of dry-contact input devices, such as conventional
heat detectors and pull stations, or monitor and power a circuit of two-wire smoke Portable Fireman’s
detectors
• Typically mounts to a 4” [10.16 cm] square box Telephone Handset
FCM-1(A)
Control and Relay Module
Features
• Addressable Control Module provides Notifier intelligent fire alarm control panels a Telephone Receptacles
circuit for Notification Appliances (horns, strobes, speakers, etc.)
Quezon City: ( 410-1155, 929-9911 • Cebu: ( 346-5413 • Davao: ( 282-8606 • [email protected] • www.multi-linegroup.com