The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by ACQ Web Design, 2020-10-23 07:22:17

Yuken

Yuken

■ Solenoid Ass'y, Coil, Receptacle and Connector Ass'y No.

Valve Model Numbers 11 20 13 18 19 Remarks
Solenoid Ass'y No. Coil No. Receptacle Connector Ass'y Connector Ass'y

Part No. Part No. Part No.

DSG-01- -A100-70 SA1-100-70 C-SA1-100-70 R1-70 Terminal
DSG-01- -A120-70 SA1-120-70 C-SA1-120-70 Box
DSG-01- -A200-70 SA1-200-70 C-SA1-200-70 KR1-A-70 Type
DSG-01- -A240-70 SA1-240-70 C-SA1-240-70 KR1-B-70
DSG-01- -D12-70 SD1-12-70 C-SD1-12-70 RR1-70
DSG-01- -D24-70 SD1-24-70 C-SD1-24-70 KR1-A-70
DSG-01- -D48-70 SD1-48-70 C-SD1-48-70 KR1-B-70
DSG-01- -R100-70 SR1-100-70 C-SR1-100-70 RR1-70
DSG-01- -R200-70 SR1-200-70 C-SR1-200-70
S-DSG-01- SD1-12-S-70 C-SD1-12-70 GDM-211-A-11 GDM-211-B-11
S-DSG-01- -D12-70 SD1-24-S-70 C-SD1-24-70
S-DSG-01- -D24-70 SD1-48-S-70 C-SD1-48-70 Plug-in
S-DSG-01- -D48-70 SR1-100-S-70 C-SR1-100-70 Connector
S-DSG-01- -R100-70 SR1-200-S-70 C-SR1-200-70 GDME-211-R-A-10 GDME-211-R-B-10 Type
DSG-01- -R200-70 SA1-100-N-70 C-SA1-100-N-70
DSG-01- -A100-N-70 SA1-120-N-70 C-SA1-120-N-70 GDM-211-A-11 GDM-211-B-11
DSG-01- -A120-N-70 SA1-200-N-70 C-SA1-200-N-70
DSG-01- -A200-N-70 SA1-240-N-70 C-SA1-240-N-70 GDME-211-R-A-10 GDME-211-R-B-10
DSG-01- -A240-N-70 SD1-12-N-70 C-SD1-12-N-70
DSG-01- -D12-N-70 SD1-24-N-70 C-SD1-24-N-70 GDML-211-1-11 GDML-211-1-11 Plug-in
DSG-01- -D24-N-70 SD1-48-N-70 C-SD1-48-N-70 Connector
DSG-01- -D48-N-70 SR1-100-N-70 C-SR1-100-N-70 GDML-211-2-11 GDML-211-2-11
DSG-01- -R100-N-70 SR1-200-N-70 C-SR1-200-N-70 GDML-211-3-11 GDML-211-3-11 with
S-DSG-01- -R200-N-70 SD1-12-S-N-70 C-SD1-12-N-70 GDML-211-1-11 GDML-211-1-11 Indicator
S-DSG-01- -D12-N-70 SD1-24-S-N-70 C-SD1-24-N-70 GDML-211-2-11 GDML-211-2-11
S-DSG-01- -D24-N-70 SD1-48-S-N-70 C-SD1-48-N-70 GDML-211-3-11 GDML-211-3-11 Light
S-DSG-01- -D48-N-70 SR1-100-S-N-70 C-SR1-100-N-70 GDML-211-1-11 GDML-211-1-11
S-DSG-01- -R100-N-70 SR1-200-S-N-70 C-SR1-200-N-70
DSG-01- -R200-N-70 SA1-100-N-70 C-SA1-100-N-70
DSG-01- -A100-N1-70 SA1-120-N-70 C-SA1-120-N-70
DSG-01- -A120-N1-70 SA1-200-N-70 C-SA1-200-N-70
DSG-01- -A200-N1-70 SA1-240-N-70 C-SA1-240-N-70
DSG-01- -A240-N1-70 SD1-12-N-70 C-SD1-12-N-70
DSG-01- -D12-N1-70 SD1-24-N-70 C-SD1-24-N-70
DSG-01- -D24-N1-70 SD1-48-N-70 C-SD1-48-N-70
S-DSG-01- -D48-N1-70 SD1-12-S-N-70 C-SD1-12-N-70
S-DSG-01- -D12-N1-70 SD1-24-S-N-70 C-SD1-24-N-70
S-DSG-01- -D24-N1-70 SD1-48-S-N-70 C-SD1-48-N-70
-D48-N1-70

Note: The connector assembly is not included in the solenoid assembly.

360 DSG-01 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

■ 3/8 Solenoid Operated Directional Valves, DSG-03 Series

These are epoch-making solenoid operated valves of high pressure, high flow Terminal Box Type E
which have been developed incorporating a unique design concept into every Plug-in Connector Type
part of the valve including the solenoid. With wet type solenoids, these
valves ensure the low noise and the long life, moreover, ensure no leakage of
oil outside of the valves.

● Wide Range of Models
Choose the optimum valve to meet your need from a large selection available.
The DSG-03 50 design series solenoid operated directional valves are
classified into the two basic models.
● Standard type …. Useable at high pressure: 31.5 MPa (4570 PSI) and high
flow: 120 L/min (31.7 U.S.GPM)
● Shockless type …. A noise at spool changeover and a vibration in piping
can be reduced to a minimum.

● Stable Operation
With a strong magnet and spring force, the valves are tough against
contamination and thus ensure a stable operation.

● Usable in products of various standards
CE/UL/CSA certified products are available.

Specifications DSG-03 Series Solenoid
Operated Directional Valves
Valve Model ★2 Max. Operating Max. T-Line Max. Changeover Approx. Mass kg(1bs.)
Type Numbers Pressure Back Pres.
Max. Flow MPa (PSI) MPa (PSI) Frequency Type of Solenoid
L /min (U.S.GPM) min-1 (Cycles/Min) AC DC, R, RQ

DSG-03-3C - -50/5090 31.5 (4570) 240 3.6 (7.9) 5 (11)
Spool Type 60 Only R Type Sol. Only 2.9 (6.4) 3.6 (7.9)
Standard DSG-03-2D2- -50/5090 120 (31.7) 16 (2320)
Type 25 (3630) 120

DSG-03-2B - -50/5090

Shockless S-DSG-03-3C - -50/5090 120 (31.7) 25 (3630) 16 (2320) 120 5 (11)
Type S-DSG-03-2B2- -50/5090 3.6 (7.9)

★1 L-DSG-03-3C - -50/5090 240 3.6 (7.9) 5 (11)
R Type Sol. Only 2.9 (6.4) 3.6 (7.9I
Low
120
Wattage L-DSG-03-2D2- -50/5090 60 (15.9) 16 (2320) 16 (2320)

(14W)Type L-DSG-03-2B - -50/5090

★1 For details of L-DSG-03, please contact us.

★2 The maximum flow means the limited flow without inducing any abnormality to the operation (changeover) of the valve. The maximum flow
differs according to the spool type and operating conditions. For details, please refer to the "List of Standard Models and Maximum Flow" on
pages 364 to 368.

Sub-plate

Piping Japanese Standard "JIS" European Design Standard N.American Design Standard Approx.
Size Mass
Sub-plate Thread Sub-plate Thread Sub-plate Thread
Model Numbers Size Model Numbers Size Model Numbers Size kg (lbs.)

3/8 DSGM-03-40 Rc 3/8 DSGM-03-2180 3/8 BSP.F DSGM-03-2190 3/8 NPT 3.0 (6.6)

1/2 DSGM-03X-40 Rc 1/2 DSGM-03X-2180 1/2 BSP.F DSGM-03X-2190 1/2 NPT 3.0 (6.6)

3/4 DSGM-03Y-40 Rc 3/4 DSGM-03Y-2180 3/4 BSP.F DSGM-03Y-2190 3/4 NPT 4.7 (10.4)

Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.

Mounting Bolts
For socket head cap screws in the table below are included.

Descriptions Soc. Hd. Cap Screw (4 pcs.) Tightening Torque

Japanese Standard "JIS" M6 × 35 Lg. 12 - 15 Nm
European Design Standard (106 - 133 in. 1bs.)

N. American Design Standard 1/4-20 UNC × 1-1/2 Lg.

DSG-03 Series Solenoid Operated Directional Valves 361

Solenoid Ratings

Valve Type Electric source Coil Frequenc y Voltage (V) Current & Power at Rated Voltage
Type (Hz) Source Rating Serviceable Range Inrush (A) 2 Holding (A) Power (W)
1 50
A100 60 100 80 - 110 5.37 0.90
AC 50 100 4.57 0.63
A120 60 5.03 0.77
Standard 50 90 - 120 4.48 0.75
Type A200 60 110 3.81 0.52
50 2.69 0.45
Shockles s DC (K Series ) A240 60 96 - 132 2.29 0.31
Type D12 120 2.52 0.38
D24 50/60 2.24 0.37
AC→ DC Rectified (R ) D100 108 - 144 1.91 0.26
R100 50/60 200 160 - 220
AC→DC Rectified (RQ) R200 200 3.16
(Quick Return ) RQ100 1.57 38
180 - 240 0.38
220 0.43

192 - 264 38
240 0.21

216 - 288 0.43 38
12 10.8 - 13.2
24 21.6 - 26.4
100 90 - 110
100 90 - 110
200 180 - 220

100 90 - 110

1. AC solenoid is not available in shockless type.
R or RQ type models with built-in current rectifier is recommended for shockless operation with AC power.

2. Inrush current in the above table show rms values at maximum stroke.
3. There are more coil types other than the above. For details, please make inquiries .

The coil type numbers in the shaded column are handled as optional extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering .

Options Lock Nut

Push Button with Lock Nut Push Button
Can be used for manual changeover of spool. The push button
can be locked in the pressed condition. Plug-in Connector
with Solenoid
Plug-in Connector with Solenoid Indicator Light Indicator Light
These are the indicator light incorporated plug-in connector type
solenoids. Energisation or de-energisation of the solenoid can SOL b
be easily identified with the incorporated indicator light.

M8 Mounting Bolts.
As the mounting bolts, M6 socket head cap screws are used for
the standard valves, however, M8 socket head cap screws are also
available for supply as optional extras. In case the M8 screws
are required, suffix "02" to the design number of both valve and
sub-plate model number like below.

(Example)
Valve: DSG-03-3C2-A100-5002
Sub-plate: DSGM-03-4002

The valve is supplied with 4 pcs. hexagon
socket head cap screws M8 × 38 Lg.

362 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

■ Model Number Designation

F- S- DSG -03 -2 B 2 A -D24 -C -N -50 -L

Series Special Two Models with
Number Reverse Mtg. of
Special Shockles Valve Number Spool- Spool Position Valve Coil Manual Electrical Design Design
Seals Type Size of Valve Spring Type Omit if not Type Override Conduit Number Standard Solenoid
Positions Arrangement Connection
Omit if not
required required

2, 3 AC:
4,40 A100
5, 60
3: C: 9,10 A120 None:
Three Spring 11,12 Japanese
Positions Centred A200 Std. "JIS"

A240 None: 90:
N.American
DC: Terminal Design Std.
D12 Box Type
None::
None: D24 Japanese
Standard Std. "JIS"
Type 2: D: 2 D100 None: and E
No-Spring European
F: Two Detented 2 R: Manual Design
For Phosphate Positions 3 (AC→DC) Override Std.
Ester Type B: 8 R100 Pin
Fluids Spring 90:
(Omit if not Offset R200 N.American
required) Design
DSG: A 1 RQ: Std. L
B 1 (AC→DC) L
Solenoid RQ100
Operated 03 50
Directional
Valve N: 2
C : Plug-in
DC: Push Connector DSG-03 Series Solenoid
Button Operated Directional Valves
D12 and Type

3: C: 2 D24 Lock Nut
4 (Option) 3
Three Spring D100
Positions Centred N1:

S: R: Plug-in
(AC DC) Connector
Shockles R100 Type
Type R200 with
Indicator
2: B: A 1 RQ: Light
B 1 (AC DC) (Option)
Two Spring
Positions Offset 2

RQ100

1. In case of the special two position valve, please refer to page 369 for details.
2. N is not available for RQ-type solenoids .
3. N1 is not available for R and RQ-type solenoids .

In the table above, the symbols or numbers highlighted with shade represent the optional
extras. The valves with model number having such optional extras are handles as options,
therefore, please confirm the time of delivery with us before ordering.

DSG-03 Series Solenoid Operated Directional Valves 363

List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-03- -A

No. of Valve Positions P AB T Max. Flow L/min PB
Spool-Spring Arrangement BA [Port "A" Blocked]
PA
[Port "B" Blocked]

Model Graphic AB AB AB
Numbers Symbols PT PT PT

Working Pressure MPa Working Pressure MPa Working Pressure MPa

10 16 25 31.5 10 16 25 31.5 10 16 25 31.5

AB 100(70) 100(48) 96(28) 65(24) 100(70) 100(48) 96(28) 65(24)
100 100 100
DSG-03-3C2 a b 100
90(49) 53(30) 34(19) 26(15) 90(49) 53(30) 34(19) 26(15)
PT 100(81) 100(81) 100(81) 100(81) 100(81) 100(81) 100(81) 100(81)
90 90 90
AB 100(81) 100(81) 100(81) 100(81) 100(81) 100(81) 100(81) 100(81)
80(65) 80(25) 100(58) 100(33) 76(22) 46(19) 100(58) 100(33) 76(22) 46(19)
DSG-03-3C3 a b 90 80
75(20) 30(15) 90(47) 50(26) 28(18) 22(15) 90(47) 50(26) 28(18) 22(15)
PT 100(75) 100(62) 100(39) 84(21) 48(18) 100(62) 100(39) 84(21) 48(18)
100 100
AB 100(25) 62(40) 47(26) 27(16) 20(12) 62(40) 47(26) 27(16) 20(12)

DSG-03-3C4 a b 80 30 30 30 26 21 18 16 30 28 28 28

PT

AB

DSG-03-3C40 a b 100

Three Positions PT
Spring Centred
AB

DSG-03-3C5 a b 30

PT

AB

DSG-03-3C60 a b 70 70 70 100 100 100 100 100 100

PT

AB

DSG-03-3C9 a b 100 100 100 100 60 60 60 60 60 60 60 60

PT 80(30) 80(20) 100(55) 100(36) 60(21) 34(16) 100(55) 100(36) 60(21) 34(16)
80
AB
30(25) 20(15) 60(38) 47(24) 23(14) 17(11) 60(38) 47(24) 23(14) 17(11)
DSG-03-3C10 a b 80 100(80) 100(65) 85(35) 62(28) 100(80) 100(65) 85(35) 62(28)

PT 100 100 100
80(60) 70(46) 51(32) 45(25) 80(60) 70(46) 51(32) 45(25)
AB
90(30) 90(20) 100(55) 100(36) 60(21) 34(16) 100(55) 100(36) 60(21) 34(16)
DSG-03-3C11 a b 100 90

PT 40(20) 20(15) 60(38) 47(24) 23(14) 17(11) 60(38) 47(24) 23(14) 17(11)

AB

DSG-03-3C12 a b 90

PT

No-Spring DSG-03-2D2 a A B b 100 100 100 100 40 40 30 28 60 60 40 35
Detented
PT

Two Positions DSG-03-2B2 A B 100 100 100 100 24 20 100(62) 100(62) 100(44) 94(37)
b 100(90) 100(90) 100(90) 100(90) 34 19 80(42) 73(36) 63(34) 51(33)
Spring Offset PT

DSG-03-2B3 A B 100 100 100 100 100(79) 100(72) 100(64) 100(59)
b 100(75) 100(75) 100(75) 100(75) 57 57 57 57 92(55) 89(46) 78(28) 70(27)
PT

DSG-03-2B8 AB b 100(35) 87(15) 61( 9 ) 49( 7 )
PT 26 19 18 16 45(21) 34(12) 15( 9 ) 11( 6 )

Notes : 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.

(Example) 50Hz, At rated voltage 100(75) 50Hz, At minimum serviceable voltage
60Hz, At rated voltage 100 (80% of rated voltage)
The maximum flow rate is
constant regardless of 50 Hz or 100(25) 60Hz, At minimum serviceable voltage
60 Hz and of any voltage (90% of rated voltage)
variants within the serviceable
voltage

2. For the maximum flow rate in P → T of the valves with a mark, please see page 368.

The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.

364 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

List of Standard Models and The Maximum Flow
Models with DC Solenoids: DSG-03- -D
Models with R Type Solenoids: DSG-03- -R
Models with RQ Type Solenoids: DSG-03- -RQ100

No. of Valve Positions P AB T Max. Flow L/min PB
Spool-Spring Arrangement BA [Port "A" Blocked]
PA
[Port "B" Blocked]

Model Graphic AB AB
Numbers Symbols PT
AB

PT PT

Working Pressure MPa Working Pressure MPa Working Pressure MPa

10 16 25 31.5 10 16 25 31.5 10 16 25 31.5
120 120
AB 80 55 80 55
120 54 43 120 54 43
DSG-03-3C2 a b 120 120 120 120 100 100 E

PT

AB

DSG-03-3C3 a b 120 120 120 120 120 120 120 120 120 120 120 120

PT

AB 84 64 84 64
120 120 120 120
DSG-03-3C4 a b 120 120 120 120
65 53 65 53
PT 120 62 49 120 62 49
120 120
AB 104 57 42 104 57 42

DSG-03-3C40 a b 120 120 120 120

Three Positions PT
Spring Centred
AB DSG-03 Series Solenoid
Operated Directional Valves
DSG-03-3C5 a b 50 50 50 50 35 24 21 20 45 45 45 45

PT

AB

DSG-03-3C60 a b 120 120 120 120 120 120 120 120 120

PT

AB

DSG-03-3C9 a b 120 120 120 120 100 100 100 100 100 100 100 100

PT 112 60 51 112 60 51
120 120
AB 120 65
50 69 46 40 69 46 40
DSG-03-3C10 a b 120 120 80 65 80 65
P T 65
100 100 100 100
AB 62 52 62 52

DSG-03-3C11 a b 120 120 120 120 120 62 51 120 62 51
120 120
PT
86 47 40 86 47 40
AB 120 65
50
DSG-03-3C12 a b 120 120
P T 65

No-Spring DSG-03-2D2 a A B b 120 120 120 120 45 37 30 28 60 60 40 35
Detented
PT

Two Positions DSG-03-2B2 A B 110 110 110 110 68 47 38 38 120 114 75 63
48
Spring Offset PT b 100 100 100 100 83 58 120
103
AB 47
37
DSG-03-2B3 b 120 120 120 120 77 77 77 77 120 120 120

PT

DSG-03-2B8 AB b 120 62
PT 53 33 24 23 120

62 40

Notes ) 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown below.

(Example) 120 At rated voltage [after temperature rise and saturated]
120
The maximum flow rate is constant regardless of At minimum serviceable voltage
any voltage variants within the serviceable voltage 65 (90% of rated voltage) [after temperature rises and saturated]

2. For the maximum flow rate in P → T of the valves with a mark, please see page 368.

The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.

DSG-03 Series Solenoid Operated Directional Valves 365

List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-03- -A

Max. Flow U.S.GPM

No. of Valve Positions P AB T PA PB
Spool-Spring Arrangement BA [Port "B" Blocked] [Port "A" Blocked]

Model Graphic AB AB AB
Numbers Symbole PT PT PT

Working Pressure PSI Working Pressure PSI Working Pressure PSI

1450 2320 3630 4570 1450 2320 3630 4570 1450 2320 3630 4570

AB 26.4 (18.5) 26.4 (12.7) 25.4 (7.4) 17.2 (6.3) 26.4 (18.5) 26.4 (12.7) 25.4 (7.4) 17.2 (6.3)

DSG-03-3C2 a b 26.4 26.4 26.4 26.4
23.8
PT 21.1 23.8 (12.9) 14.0 (7.9) 9.0 (5.0) 6.7 (4.0) 23.8 (12.9) 14.0 (7.9) 9.0 (5.0) 6.7 (4.0)
26.4
AB 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4)

DSG-03-3C3 a b 23.8 23.8 23.8

PT 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4) 26.4 (21.4)

AB 21.1 (17.2) 21.1 (6.6) 26.4 (15.3) 26.4 (8.7) 20.1 (5.8) 12.2 (5.0) 26.4 (15.3) 26.4 (8.7) 20.1 (5.8) 12.2 (5.0)

DSG-03-3C4 a b 21.1 19.8 (5.3) 7.9 (4.0) 23.8 (12.4) 13.2 (6.9) 7.4 (4.8) 5.8 (4.0) 23.8 (12.4) 13.2 (6.9) 7.4 (4.8) 5.8 (4.0)

PT

AB 26.4 (19.8) 26.4 (16.4) 26.4 (10.3) 22.2 (5.5) 12.7 (4.8) 26.4 (16.4) 26.4 (10.3) 22.2 (5.5) 12.7 (4.8)

DSG-03-3C40 a b 26.4 26.4

PT 26.4 (6.6) 16.4 (10.6) 12.4 (6.9) 7.1 (4.2) 5.3 (3.2) 16.4 (10.6) 12.4 (6.9) 7.1 (4.2) 5.3 (3.2)

Three Positions AB
Spring Centred
DSG-03-3C5 a b 7.9 7.9 7.9 7.9 6.9 5.5 4.8 4.2 7.9 7.4 7.4 7.4

PT

AB

DSG-03-3C60 a b 18.5 18.5 18.5 26.4 26.4 26.4 26.4 26.4 26.4

PT

AB

DSG-03-3C9 a b 26.4 26.4 26.4 26.4 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9

PT

AB 21.1 (7.9) 21.1 (5.3) 26.4 (14.5) 26.4 (9.5) 15.9 (5.5) 9.0 (4.2) 26.4 (14.5) 26.4 (9.5) 15.9 (5.5) 9.0 (4.2)

DSG-03-3C10 a b 21.1 21.1 7.9 (6.6) 5.3 (4.0) 15.9 (10) 12.4 (6.3) 6.1 (3.7) 4.5 (2.9) 15.9 (10) 12.4 (6.3) 6.1 (3.7) 4.5 (2.9)
26.4
PT 23.8

AB 26.4 (21.1) 26.4 (17.2) 22.5 (9.2) 16.4 (7.4) 26.4 (21.1) 26.4 (17.2) 22.5 (9.2) 16.4 (7.4)

DSG-03-3C11 a b 26.4 26.4 26.4

PT 21.1 (15.9) 18.5 (12.2) 13.5 (8.5) 11.9 (6.6) 21.9 (15.9) 18.5 (12.2) 13.5 (8.5) 11.9 (6.6)

AB 23.8 (7.9) 23.8 (5.3) 26.4 (14.5) 26.4 (9.5) 15.9 (5.5) 9.0 (4.2) 26.4 (14.5) 26.4 (9.5) 15.9 (5.5) 9.0 (4.2)

DSG-03-3C12 a b 23.8 10.6 (5.3) 5.3 (4.0) 15.9 (10) 12.4 (6.3) 6.1 (3.7) 4.5 (2.9) 15.9 (10) 12.4 (6.3) 6.1 (3.7) 4.5 (2.9)

PT

No-Spring DSG-03-2D2 a A B b 26.4 26.4 26.4 26.4 10.6 10.6 7.9 7.4 15.9 15.9 10.6 9.2
Detented
PT

Two Positions Spring Offset DSG-03-2B2 AB 26.4 26.4 26.4 26.4 9.0 6.3 5.3 5.0 26.4 (16.4) 26.4 (16.4) 26.4 (11.6) 24.8 (9.8)
DSG-03-2B3 15.1 15.1 15.1 15.1 21.1 (11.1) 19.3 (9.5) 16.6 (9.0) 13.5 (8.7)
DSG-03-2B8 PT b 5.0 4.8 4.2 26.4 (20.9) 26.4 (19) 26.4 (16.9) 26.4 (15.6)
AB 24.3 (14.5) 23.5 (12.2) 20.6 (7.4) 18.5 (7.1)
26.4 (23.8) 26.4 (23.8) 26.4 (23.8) 26.4 (23.8) 26.4 (9.2) 23 (4.0) 16.1 (2.4) 12.9 (1.8)
PT 11.9 (5.5) 9.0 (3.2) 4.0 (2.4) 2.9 (1.6)
AB 26.4 26.4 26.4 26.4

PT b

26.4 (19.8) 26.4 (19.8) 26.4 (19.8) 26.4 (19.8)

b 6.9

Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown below.

(Example) 50Hz, At rated voltage 50Hz, At minimum serviceable voltage
60Hz, At rated voltage (80% of rated voltage)
The maximum flow rate is 26.4(19.8)
constant regardless of 50 Hz or 26.4
60 Hz and of any voltage 26.4(6.6)
variants within the serviceable
voltage 60Hz, At minimum serviceable voltage
(90% of rated voltage)

2. For the maximum flow rate in P → T of the valves with a mark, please see page 368.

The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.

366 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

List of Standard Models and The Maximum Flow

Models with DC Solenoids: DSG-03- -D
Models with R Type Solenoids: DSG-03- -R
Models with RQ Type Solenoids: DSG-03- -RQ100

Max. Flow U.S. GPM

No. of Valve Positions P AB T PA PB
Spool-Spring Arrangement BA [Port "B" Blocked] [Port "A" Blocked]

Model Graphic AB AB AB
Numbers Symbols PT PT PT

Working Pressure PSI Working Pressure PSI Working Pressure PSI

1450 2320 3630 4570 1450 2320 3630 4570 1450 2320 3630 4570

AB 31.7 21.1 14.5 31.7 21.1 14.5 E

DSG-03-3C2 a b 31.7 31.7 31.7 31.7 31.7 26.4 14.3 11.4 31.7 26.4 14.3 11.4

PT

AB

DSG-03-3C3 a b 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7

PT

AB 22.2 16.9 22.2 16.9

DSG-03-3C4 a b 31.7 31.7 31.7 31.7 31.7 31.7 17.2 14 31.7 31.7 17.2 14

PT

AB 31.7 16.4 12.9 31.7 16.4 12.9

DSG-03-3C40 a b 31.7 31.7 31.7 31.7 31.7 27.5 15.1 11.1 31.7 27.5 15.1 11.1

Three Positions PT
Spring Centred
AB DSG-03 Series Solenoid
Operated Directional Valves
DSG-03-3C5 a b 13.2 13.2 13.2 13.2 9.2 6.3 5.5 5.3 11.9 11.9 11.9 11.9

PT

AB

DSG-03-3C60 a b 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7

PT

AB

DSG-03-3C9 a b 31.7 31.7 31.7 31.7 26.4 26.4 26.4 26.4 26.4 26.4 26.4 26.4

PT

AB 31.7 17.2 29.6 15.9 13.5 29.6 15.9 13.5

DSG-03-3C10 a b 31.7 31.7 17.2 13.2 31.7 18.2 12.2 10.6 31.7 18.2 12.2 10.6

PT

AB 21.1 17.2 21.1 17.2

DSG-03-3C11 a b 31.7 31.7 31.7 31.7 26.4 26.4 16.4 13.7 26.4 26.4 16.4 13.7

PT

AB 31.7 17.2 31.7 16.4 13.5 31.7 16.4 13.5

DSG-03-3C12 a b 31.7 31.7 17.2 13.2 31.7 22.7 12.4 10.6 31.7 22.7 12.4 10.6

PT

No-Spring DSG-03-2D2 a A B b 31.7 31.7 31.7 31.7 11.9 9.8 7.9 7.4 15.9 15.9 10.6 9.2
Detented
PT

Two Positions DSG-03-2B2 AB 29.1 29.1 29.1 29.1 30.1 19.8 16.6
DSG-03-2B3 18 12.4 10 10 31.7 12.7
Spring Offset DSG-03-2B8 PT b 26.4 26.4 26.4 26.4 21.9 15.3 31.7
AB 27.2
b 31.7 31.7 31.7 31.7 20.3 20.3 20.3 20.3 31.7 31.7 31.7 12.4
PT
AB 31.7 16.4 9.8
14 8.7 6.3 6.1 31.7
PT b 16.4 10.6

Notes ) 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown below.

(Example)

The maximum flow rate is constant regardless of 22.2 At rated voltage [after temperature rise and saturated]
any voltage variants within the serviceable voltage 31.7
At minimum serviceable voltage
17.2 (90% of rated voltage) [after temperature rises and saturated]

2. For the maximum flow rate in P → T of the valves with a mark, please see page 368.

The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.

DSG-03 Series Solenoid Operated Directional Valves 367

Maximum Flow of Centre By-Pass

In valve type 3C3, 3C5 and 3C60, in case where the actuator is put on in between the cylinder ports A and B as illustrated
below and where the actuator moves and suspended at its stroke end and where the valve is then shifted to the neutral
position in the suspended state of the actuator, the maximum flow rates available are those as shown as the table below
regardless of any voltage in the range of serviceable voltage.

Graphic Max. Flow L/min (U.S.GPM)
Symbols
Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
DSG-03-3C3-A 100 (26.4)
DSG-03-3C3-D /R /RQ100 AB b 120 (31.7) 100 (26.4) 100 (26.4) 100 (26.4)
DSG-03-3C5-A a b
DSG-03-3C5-D /R /RQ100 b 26 (6.9) 120 (31.7) 120 (31.7) 120 (31.7)
DSG-03-3C60-A PT 35 (9.2)
DSG-03-3C60-D /R /RQ100 84 (22.2) 21 (5.5) 18 (4.8) 16 (4.2)
AB 68 (18.0)
a 24 (6.3) 21 (5.5) 20 (5.3)

PT 52 (13.7) 52 (13.7)

AB 65 (17.2) 61 (16.1)
a

PT

List of Shockless Models and The Maximum Flow
Models with DC Solenoids: S-DSG-03- -D
Models with R Type Solenoids: S-DSG-03- -R
Models with RQ Type Solenoids: S-DSG-03- -RQ100

Max. Flow L/min (U.S.GPM)

P AB T PA PB
BA [Port "B" Blocked] [Port "A" Blocked]

No. of Valve Model Graphic AB AB AB
Positions Numbers Symbols PT PT PT
Spool-Spring
Arrangement

Working Pressure MPa (PSI) Working Pressure MPa (PSI) Working Pressure MPa (PSI)

5 10 16 25 5 10 16 25 5 10 16 25

(730) (1450) (2320) (3630) (730) (1450) (2320) (3630) (730) (1450) (2320) (3630)

AB 120 (31.7) 75 (19.8) 50 (13.2) 120 (31.7) 75 (19.8) 50 (13.2)

Three S-DSG-03-3C2 a b 120 (31.7) 120 (31.7) 120 (31.7) 120 (31.7) 120 (31.7) 105 (27.7) 65 (17.2) 40 (10.6) 120 (31.7) 105 (27.7) 65 (17.2) 40 (10.6)
Positions
Spring PT
Centred
AB 85 (22.5) 65 (17.2) 120 (31.7) 75 (19.8) 40 (10.6) 120 (31.7) 75 (19.8) 40 (10.6)

S-DSG-03-3C4 a b 120 (31.7) 120 (31.7) 70 (18.5) 45 (11.9) 120 (31.7) 100 (26.4) 65 (17.2) 35 (9.2) 120 (31.7) 100 (26.4) 65 (17.2) 35 (9.2)

PT

Two S-DSG-03-2B2 AB 105 (27.7) 60 (15.9)
Positions PT b 120 (31.7) 100 (26.4) 75 (19.8) 40 (10.6) 39 (10.3) 39 (10.3) 39 (10.3) 39 (10.3) 120 (31.7) 120 (31.7)
Spring
Offset 80 (21.1) 50 (13.2)

Note: The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown below.

(Example)

L/ min U.S.GPM At rated voltage
[after temperature rise and saturated]
The maximum flow rate is constant regardless of 120 (31.7)
any voltage variants within the serviceable voltage 120 (31.7) At minimum serviceable voltage
(90% of rated voltage)
80 (21.1) [after temperature rises and saturated]

368 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

Reverse Mounting of Solenoid

In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b position
(side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in the reverse
position -SOL a side- is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B A and 2B B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.

AB b AB
PT
a
PT

Standard Mtg. of Solenoid Reverse Mtg. of Solenoid

Valves Using Neutral Position and Side Position (Special Two Position Valve) E

Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and MaximumFlow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B).

(Example) In case of Spool Type "2"

SOL. a Energised Neutral Position
Position
SOL. b Energised
Position

AB b DSG-03 Series Solenoid
a Operated Directional Valves

PT

2B2A 2B2B
AB AB

b b

PT PT

"A": Use of Neutral and "B": Use of Neutral and
SOL. a Energised SOL. b Energised
Position (2B2A) Position (2B2B)

Graphic SymbolsG raphic Symbols

Model Numbers Standard Reverse Model Numbers Standard Reverse
Mtg. Type Mtg. Type Mtg. Type Mtg. Type
(S-) DSG-03-2B A DSG-03-2B B
(S-) DSG-03-2B2A AB ba AB (S-) DSG-03-2B2B AB ba AB
PT PT PT PT
DSG-03-2B3B
(S-) DSG-03-2B4B

DSG-03-2B60B
DSG-03-2B10B

In the above table, the graphic symbols in mounting
type highlighted with shade are optional extra,
therefore, please confirm the time of delivery with
us before ordering.

DSG-03 Series Solenoid Operated Directional Valves 369

Typical Changeover Time
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
Standard Type (Without Shockless Function)

[Test Conditions] [Result of Measurement]

Pressure: 16 MPa (2320 PSI) ON

Flow Rate: 70 L/min (18.5 U.S.GPM) Solenoid OFF OFF
Viscosity: 30 mm2 /s (140 SSU) Spool Shift 0

Voltage: 100 %V (After coil temperature rises and saturated) T2

0
Max.
T1

Type Model Numbers Changeover Time ms
T1 T2
Standard DSG-03-3C2-A 27 22
Type DSG-03-3C2-D 97 30
DSG-03-3C2-R 97 204
DSG-03-3C2-RQ100 97 41

Shockless Type [Result of Measurement]
[Test Circuit and Conditions]
Accelmeter ON OFF
ab Speed SOL a G1 G2
Ps Acceleration (G)
Load Pressure (Ps)

T1 Time T2

Setting Pressure (Ps): 7 MPa (1020 PSI) Time Acceleration
m/s2 (G)
Load (W): 1000 kg (2205 1bs.) Type Model Numbers ms G1 G2

Speed: 8.8 m/min (28.9 ft./min) Shockless T1 T2 6.4 6.4
Viscosity: 30 mm2/s (140 SSU) Type (.65) (.65)
S-DSG-03-3C2- D 110 120

S-DSG-03-3C2- R 110 220

S-DSG-03-3C2-RQ100 110 120

370 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

Pressure Drop
Pressure drop curves based on viscosity of 35 mm2/s (164 SSU) and specific gravity of 0.850.

Standard Type: DSG-03Pressure Drop P 1 Model Numbers Pressure Drop Curve Number
P→A B→T P→ B A→ T P→T
PSI MPa 2 DSG-03-3C2
2.5 3 DSG-03-3C3 7777
DSG-03-3C4 99995
350 4 DSG-03-3C40 7878
5 DSG-03-3C5 7777
300 2.0 DSG-03-3C60 97791
DSG-03-3C9 65651
250 DSG-03-3C10 9797
1.5 DSG-03-3C11 7877
DSG-03-3C12 9777
200 DSG-03-2D2 7778
DSG-03-2B2 4366
150 1.0 DSG-03-2B3 2177
DSG-03-2B8 3299
100 6 65 E
7
0.5 98
50

0
0 0 20 40 60 80 100 120 L/ min

0 5 10 15 20 25 30 35 U.S.GPM
Flow Rate

Shockless Type: S-DSG-03 1 DSG-03 Series Solenoid
Operated Directional Valves
PSI MPa

350 2.5

Pressure Drop P 300 2
2.0
Model Numbers Pressure Drop Curve Number
250 P→A B→T P→B A→T
1.5 S-DSG-03-3C2
S-DSG-03-3C4 22 22
200 S-DSG-03-2B2 2233

150 1.0 3 1222

100
0.5

50

0
0

0 20 40 60 80 100 120 L/ min

0 5 10 15 20 25 30 35 U.S.GPM
Flow Rate

For any other viscosity, multiply the factors in the table below.

mm2/s 15 20 30 40 50 60 70 80 90 100
Viscosity

SSU 77 98 141 186 232 278 324 371 417 464

Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30

For any other specific gravity (G'), the pressure drop ( P') may be
obtained from the formula below.

P' = P (G'/0.850)

DSG-03 Series Solenoid Operated Directional Valves 371

Mounting surface: ISO 4401-AC-05-4-A

TERMINAL BOX TYPE

Models with AC Solenoids: DSG-03- -A -50/5090
Double Solenoid: Spring Centred & No-Spring Detended

Cylinder Port "A "

Solenoid Indicator Light Pressure Port "P"
Cylinder Port "B"
(For Sol b) 91 54
(2.13)
(3.58)

Model Numbers "C " Thd. 32.5
DSG-03- -A -50 G 1/2 (1.28)
DSG-03- -A -5090 1/2 NPT 46
(1.81)

7(.28) Dia. Through 50.8 Solenoid Indicator Light
(2.00) (For Sol a)
11(.43) Dia. Spotface
4 Places Tank Port "T "

Space Needed to Remove 236
Solenoid-Each End (9.29)

47.5 179.5
(1.87) (7.07)

Electrical Conduit Connection 123
"C " Thd. (Both Ends) (4.84)
34.5
58 (1.36)
(2.28)

32 35.3
(1.26) (1.39)

70 89.5
(2.76) (3.52)

Manual Actuator 105.3
6.3(.25) Dia. (4.15)
27
(1.06)
Lock Nut 19
Tightening Torque: Mounting Surface
8.5-10.5 Nm (75-93 IN.lbs.) (.75) (O-Rings Furnished)
92

(3.62)

. Of the two of tank port "T", the tank port in the left side is normally used in our standard sub-plate, DIMENSIONS IN
though, either side of the tank port "T" can be used without problem. MILLIMETRES (INCHES)

Single Solenoid: Spring Offset

179.5
(7.07)

372 176.3
(6.94)
For other dimensions, refer to "Spring Centred and No-Spring Detented" medels.
Solenoid being mounted in the reverse position -SOL a side- is also available.

DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

Mounting surface: ISO 4401-AC-05-4-A

TERMINAL BOX TYPE

Models with DC Solenoids : (S-)DSG-03- -D -50/5090

Models with R Type Solenoids : (S-)DSG-03- -R -50/5090

Models with RQ Type Solenoids : (S-)DSG-03- -RQ100-50/5090

Double Solenoid: Spring Centred & No-Spring Detented

Single Solenoid: Spring Offset Space Needed to Remove 282
Solenoid-Each End (11.10)
58 202.5
(2.28) 70.5
(2.78) (7.97)

35.3 L SOL b SOL a L' E
(1.39)

89.5
(3.52)

105.3
(4.15)

32 114 Double Solenoid
(4.49) Models Only
(1.26)
70 199.3
(7.85)
(2.76)

For other dimensions, refer to Models with AC solenoids (Page 372). S
Q
Sub- plates DIMENSIONS IN 76
MILLIMETRES (INCHES) (2.99)
DSGM-03 -40/2180/2190
L DSG-03 Series Solenoid
J 90 N Operated Directional Valves
P
18 (3.54)
(.71) 54

8.8 (.35) Dia. Through (2.13) "D" Thd. "E" Deep
14 (.55) Dia. Spotface 37.3 4 Places
4 Places
(1.47) K
27 T
7
90 10 (.39) 46 22 (.87) (1.06) 20 (.28)
(.79)
16.7

(.66)
3.2

(.13)

6.4 (.25) P

(3.54) (1.81) 32.5 (1.28) 21.4 (.84) 70
(2.76)
A
110 B
(4.33)

T

11 (.43) Dia. H 92
4 Places
(3.62) "C" Thd.
F 4 Places

Sub-plate Piping Size "D" Thd. Dimensions mm (Inches)
Model Numbers "C" Thd.
DSGM-03-40 Rc 3/8 E FH JK LN PQ S T
DSGM-03-2180 3/8 BSP.F
DSGM-03-2190 3/8 NPT M6 13 (.51) 110 9 10 32 62 40 16 48 21 24
DSGM-03X-40 Rc 1/2 (4.33) (.35) (.39) (1.26) (2.44) (1.57) (.63) (1.89) (.83) (.94)
DSGM-03X-2180 1/2 BSP.F
DSGM-03X-2190 1/2 NPT 1/4-20 UNC 15 (.59)
DSGM-03Y-40 Rc 3/4
DSGM-03Y-2180 3/4 BSP.F M6 13 (.51) 110 9 10 32 62 40 16 48 21 24
DSGM-03Y-2190 3/4 NPT (4.33) (.35) (.39) (1.26) (2.44) (1.57) (.63) (1.89) (.83) (.94)

1/4-20 UNC 15 (.59)

M6 13 (.51) 120 14 15 50 80 45 10 47 16 42
(4.72) (.55) (.59) (1.97) (3.15) (1.77) (.39) (1.85) (.63) (1.65)

1/4-20 UNC 15 (.59)

DSG-03 Series Solenoid Operated Directional Valves 373

PLUG-IN CONNECTOR TYPE (N)
PLUG-IN CONNECTOR WITH INDICATOR LIGHT (N1)

Models with AC Solenoids: DSG-03- -A - NN1-50/5090

The position of the Plug-in connector can be changed as Cable Departure
illustrated below by loosening the lock nut. After
completion of the change, be sure to tighten the lock nut Cable Applicable:
with the torque as specified below. Outside Dia. ...... 8-10mm(.31-.39 in.)
Conductor Area ..... Not Exceeding 1.5mm2 (.0023 Sq. in.)
27.5(1.08)
236
(9.29)

91
(3.58)

39 35 89

(1.54)(1.38) (3.50)

35.3 61.8SOLb SOLa
(1.39) (2.43)

109.1
(4.30)
61.8
(2.43)

(1.26) 176.3 Double Solenoid
70 (6.94) Models Only
Lock Nut
(2.76) Tightening Torque:
8.5 - 10.5 Nm (75-93 IN.lbs.)

Models with DC Solenoids: (S-)DSG-03- -D - NN1-50/5090

Models with R Type Solenoids: (S-)DSG-03- -R -N-50/5090

The position of the Plug-in connector can be changed as Cable Departure
illustrated below by loosening the lock nut. After Cable Applicable:
completion of the change, be sure to tighten the lock nut Outside Dia. ..... 8-10mm(.31-.39 in.)
with the torque as specified below. Conductor Area ..... Not Exceeding 1.5mm2 (.0023 Sq. in.)

E 282

(11.10)

114

(4.49)

F 35 89

(1.38) (3.50)

35.3 D SOL b SOL a
(1.39)

C

(1.26) 199.3 Double Solenoid
Models Only
70 Lock Nut (7.85)
(2.76)
Tightening Torque:

8.5 - 10.5 Nm (75-93 IN.lbs.)

Model Numbers Dimensions mm (Inches) For other dimensions, refer to "Terminal Box Type"
(Page 372 – 373).

CD EF

DSG-03- -D - NN1-50/5090 121.1 (4.77) 73.8 (2.91) 27.5 (1.08) 39 (1.54)

DSG-03- -R -N-50/5090 124.9 (4.92) 62.6 (2.46) 34 (1.34) 53 (2.09)

Options DIMENSIONS IN
MILLIMETRES (INCHES)

Models with Push Button & Lock Nut: (S-)DSG-03- - C(- NN1)-50/5090

Lock Nut AC : 158.5 (6.24)
Press the "Push Button" then turn "Lock Nut" DC,R,RQ : 181.5 (7.15)
clockwise. The position of the "Push Button" is
held.
Be sure to loosen "LockNut" fully before solenoid
is energised

Push Button

374 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

Details of Receptacle

Type of Double Solenoid Type Single Solenoid Type
Electrical Conduit

Connection

3 Power Supply Earth
(For SOL.a)
Power Supply
(For SOL.b)

Earth 1

Indicatot Indicator
Light Light

Terminal SOL. b SOL. a SOL. b
Box Type

Common Plate 2 Indicator Light Power
Common Earth 1 Supply

Ground E

Plug-in 1-Power Supply 3 1
Connector
1
Type
3 2-Power Supply 3

3 2

2

1. There are two grounding terminals. You can use either one. DANGER DSG-03 Series Solenoid
2. If you do not need the common plate, remove it. Operated Directional Valves
3. With DC solenoids, polarity is no question. Do not perform wiring while the power is on.
Doing so may result in electric shock, burns or death.
Make the wiring properly. Improper wiring will cause an
irregular movement of the machine, resulting in a grave
accident.

Electrical Circuit AC Electric Source AC→ DC Rectified
DC
Type of
Electrical Conduit

Connection

Indicator Light Indicator Light Indicator Light

Power Power Power Voltage-Surge
Supply Supply Supply Suppressor

Terminal SOL. SOL. SOL.
Box Type

Common Common Voltage-Surge Common Rectifier
Ground Ground Suppressor Ground Circuit

Indicator Light Voltage-Surge
Suppressor
(Integrated in "N1"
model only) SOL.

SOL. Rectifier
Circuit
1-Power 1-Power 1-Power
Supply Supply Supply

Plug-in 2-Power SOL. 2-Power
Connector Supply Supply
Ground 2-Power Ground
Type Supply

Ground

Indicator Light Voltage-Surge
(Integrated in "N1"
model only) Suppressor
(Circuit composed
in coil)

DSG-03 Series Solenoid Operated Directional Valves 375

■ List of Seals
-DSG-03- - -50/5090

18 16 Spring Offset Type
25 43 42 41 40 44
29
30 26 19 21 20 22 24 31 17 23 15
14
SOL b SOL a 28
27

1 2 27 3 6 4 10

-DSG-03- -N/N1-50/5090

46 47 48 45 16

SOL b SOL a

List of Seals

Item Name of Parts Part Numbers Qty. Remarks
3C 2D2 2B Included in Solenoid Ass'y (Item 16 )

21 Gasket 1751S-VK418689-6 111

27 O-Ring SO-NB-A014(NBR, Hs90) 5 5 5

28 O-Ring SO-NB-P21 1

29 Plug 1790S-VK418329-9 2

30 O-Ring S6 222

41 O-Ring SO-NB-P21 221

43 O-Ring SO-NA-P4 442

When ordering the O-Rings, please specify the seal kit number from the table below.

Valve Model Numbers Seal Kit No. O-Ring Details for Seal Kit
DSG-03- - -50/5090 KS-DSG-03-50 27 (5 Pcs.), 28 & 41 (2 Pcs., see above), 43 (4 Pcs.)
DSG-03- - -N-50/5090 KS-DSG-03-N-50 27 (5 Pcs.), 28 & 41 (2 Pcs., see above)

Solenoid Ass'y, Coil, Receptacle and Connector

Refer to Page 377 for the details of these parts.

376 DSG-03 Series Solenoid Operated Directional Valves

DIRECTIONAL CONTROLS

■ Solenoid Ass'y, Coil, Receptacle and Connector Ass'y No.

Valve Model Numbers 16 42 17 45 46 Remarks
Solenoid Ass'y No. Coil No. Receptacle Connector Ass'y Connector Ass'y

Part No. Part No. Part No.

DSG-03- -A100-50 SA3-100-51 C-SA3-100-51 R3-60 Terminal
DSG-03- -A120-50 SA3-120-51 C-SA3-120-51 Box
DSG-03- -A200-50 SA3-200-51 C-SA3-200-51 KR3-A-60 Type
DSG-03- -A240-50 SA3-240-51 C-SA3-240-51 KR3-C-60
DSG-03- -D12-50 SD3-12-51 C-SD3-12-51 RR3-60 E
DSG-03- -D24-50 SD3-24-51 C-SD3-24-51 QR3-C-60
DSG-03- -D100-50 SD3-100-51 C-SD3-100-51 KR3-A-60
DSG-03- -R100-50 SR3-100-51 C-SR3-100-51 KR3-C-60
DSG-03- -R200-50 SR3-200-51 C-SR3-200-51 RR3-60
DSG-03- -RQ100-50 SR3-100-51 C-SR3-100-51 QR3-C-60
S-DSG-03- SD3-12-S-51 C-SD3-12-51
S-DSG-03- -D12-50 SD3-24-S-51 C-SD3-24-51 GDM-211-A-11 GDM-211-B-11 DSG-03 Series Solenoid
S-DSG-03- -D24-50 SD3-100-S-51 C-SD3-100-51 Operated Directional Valves
S-DSG-03- -D100-50 SR3-100-S-51 C-SR3-100-51 Plug-in
S-DSG-03- -R100-50 SR3-200-S-51 C-SR3-200-51 Connector
S-DSG-03- -R200-50 SR3-100-51 C-SR3-100-51 GDME-211-R-A-10 GDME-211-R-B-10 Type
DSG-03- -RQ100-50 SA3-100-N-51 C-SA3-100-N-51
DSG-03- -A100-N-50 SA3-120-N-51 C-SA3-120-N-51 GDM-211-A-11 GDM-211-B-11
DSG-03- -A120-N-50 SA3-200-N-51 C-SA3-200-N-51
DSG-03- -A200-N-50 SA3-240-N-51 C-SA3-240-N-51 GDME-211-R-A-10 GDME-211-R-B-10
DSG-03- -A240-N-50 SD3-12-N-51 C-SD3-12-N-51
DSG-03- -D12-N-50 SD3-24-N-51 C-SD3-24-N-51 GDML-211-1-11 GDML-211-1-11 Plug-in
DSG-03- -D24-N-50 SD3-100-N-51 C-SD3-100-N-51 Connector
DSG-03- -D100-N-50 SR3-100-N-51 C-SR3-100-N-51 GDML-211-2-11 GDML-211-2-11
DSG-03- -R100-N-50 SR3-200-N-51 C-SR3-200-N-51 GDML-211-3-11 GDML-211-3-11 with
S-DSG-03- -R200-N-50 SD3-12-S-N-51 C-SD3-12-N-51 GDML-211-1-11 GDML-211-1-11 Indicator
S-DSG-03- -D12-N-50 SD3-24-S-N-51 C-SD3-24-N-51 GDML-211-2-11 GDML-211-2-11
S-DSG-03- -D24-N-50 SD3-100-S-N-51 C-SD3-100-N-51 GDML-211-3-11 GDML-211-3-11 Light
S-DSG-03- -D100-N-50 SR3-100-S-N-51 C-SR3-100-N-51 GDML-211-1-11 GDML-211-1-11
S-DSG-03- -R100-N-50 SR3-200-S-N-51 C-SR3-200-N-51
DSG-03- -R200-N-50 SA3-100-N-51 C-SA3-100-N-51
DSG-03- -A100-N1-50 SA3-120-N-51 C-SA3-120-N-51
DSG-03- -A120-N1-50 SA3-200-N-51 C-SA3-200-N-51
DSG-03- -A200-N1-50 SA3-240-N-51 C-SA3-240-N-51
DSG-03- -A240-N1-50 SD3-12-N-51 C-SD3-12-N-51
DSG-03- -D12-N1-50 SD3-24-N-51 C-SD3-24-N-51
DSG-03- -D24-N1-50 SD3-100-N-51 C-SD3-100-N-51
S-DSG-03- -D100-N1-50 SD3-12-S-N-51 C-SD3-12-N-51
S-DSG-03- -D12-N1-50 SD3-24-S-N-51 C-SD3-24-N-51
S-DSG-03- -D24-N1-50 SD3-48-S-N-51 C-SD3-100-N-51
-D100-N1-50

Note : The connector assembly is not included in the solenoid assembly.

DSG-03 Series Solenoid Operated Directional Valves 377

DIRECTIONAL CONTROLS

■ Solenoid Controlled Pilot Operated Directional Valves

These valves are composed of a solenoid operated pilot valve and a pilot
operated slave valve. When a solenoid is energised the pilot valve
directs the flow to move the spool of the slave valve, thus changing the
direction of flow in the hydraulic circuit.

● High Pressure High Flow
High pressure [31.5 MPa (4570 PSI)] along which high flow means
compact system design.

● Lower Pressure Drop
System energy saving increased as pressure drop of each valve has been
greatly reduced.

E

Specifications Solenoid Controlled
Pilot Operated Directional Valves
Valve Model Numbers ★1 Max. Max. Pilot Min. ★2 Max. T-Line Back Max. Change- Mass
Type Operating Pressure Required Pressure over Frequecy kg
Max. Flow Pressure MPa (PSI) Pilot Pres. MPa (PSI) Cycles/Min {min–1}
L/min MPa (PSI) MPa (PSI) AC DC R (1bs.)
Ext. Drain Int. Drain
(U.S.GPM)

DSHG-01-3C - -14/1480/1490 40 (10.6) 21 (3050) 21 (3050) 1.0 (145) 16 (2320) 16 (2320) 120 120 120 3.2 (7.1)

DSHG-01-2B - -14/1480/1490 2.7 (6.0)

DSHG-03-3C - -14/1490 6.9 (15.2)

DSHG-03-2N - -14/1490 160 (42.3) 25 (3630) 25 (3630) 0.7 (100) 16 (2320) 16 (2320) 120 120 120 6.9 (15.2)

Standard DSHG-03-2B - -14/1490 6.4 (14.1)
Type (S-)DSHG-04-3C - -52/5290 8.5 (18.7)

(S-)DSHG-04-2N - -52/5290 300 (79.3) 31.5 (4570) 25 (3630) 0.8 (120) 21 (3050) 16 (2320) 120 120 120 8.5 (18.7)

(S-)DSHG-04-2B - -52/5290 8.0 (17.6)

(S-)DSHG-06-3C - -53/5390 ★3 12.4 (27.3)
(S-)DSHG-06-2N - -53/5390
(S-)DSHG-06-2B - -53/5390 500 (132) 25 (3630) 0.8 (120) 120 120 120 12.4 (27.3)
31.5 (4570) 21 (3050) 16 (2320)
11.9 (26.2)

Shockless (S-)DSHG-06-3H - -53/5390 21 (3050) 1.0 (145) 110 110 110 13.2 (29.1)

Type (S-)DSHG-10-3C - -43/4390 25 (3630) 120 120 100 45.0 (99.2)

(S-)DSHG-10-2N - -43/4390 ★3 100 100 100 45.0 (99.2)
1100 (291) 31.5 (4570) 1.0 (145) 21 (3050) 16 (2320)
(S-)DSHG-10-2B - -43/4390 44.5 (98.1)
21 (3050) 60 60 50
(S-)DSHG-10-3H - -43/4390 52.9 (116.6)

★1. Maximum flow indicates a ceiling flow. As the ceiling flow depends on the type of Yuken can offer flanged connection valves described below.
spool and operating condition, refer to the List of Spool Functions on pages 386 to 390 Consult us for the details.
for details.
Model Numbers Rated Flow Max. Pressure
★2. Pilot pressure of internal pilot drain models must always exceed tank line back pressure l/min (U.S.GPM) MPa (PSI)
by a minimum required pilot pressure. DSHF-10- - -27 21 (3050)
DSHF-16- - -37 315 (83) 21 (3050)
★3. Min. pilot pressure of with pilot piston in 1.8 MPa (260 PSI). DSHF-24- - -28 500 (132) 21 (3050)
DSHF-32- - -27 1200 (317) 21 (3050)
■ Solenoid Ratings 2400 (634)

Solenoid ratings of pilot valve are identical with those of standard solenoid
valve. Refer to relevant solenoid ratings described on the page below.

Model Pilot Valve Model Solenoid Ratings described CSA Approved Solenoid Valve
Numbers Numbers on the page below
Available to supply DSHG-06 series valve approved
DSHG-01 DSG-01- - -70 345 by the CSA (Canadian Standards Association).
DSHG-03 Consult us for details.
(S-)DSHG-04
(S-)DSHG-06
(S-)DSHG-10

Solenoid Controlled Pilot Operated Directional Valves 381

■ Model Number Designation

F- S- DSHG -06 -2 B 2 A -C2 -E T

Special Series Valve No. of Spool-Spring Spool Special Two Models with Pilot Drain
Seals Type Number Size Valve Arrangement Type Position Pilot Choke Connec- Connec-
Position Valve
Valve tion tion

2, 3, 4
C: 40, 5, 60
3 Spring Centred 7, 9, 10

01 11, 12

2 B: 2, 3, 4
Spring Offset 40, 7

None: 2, 3, 4
Standard
Type 3 C: 40, 5, 60
Spring Centred 7, 9, 10

11, 12

F: DSHG: 03 N: 2 None: None:
For Solenoid 04 No-Spring 3 C1 : Internal External
Phos- Controlled 2 4
phate Pilot 40
Ester Operated B: 7
Type Directional Spring Offset
Fluids Valve,
Sub-plate 2, 4, 40 With C1 Pilot Drain
( )Omit if not Mounting Choke E: E:
C: 60, 10, 12
required Spring Centred 3, 5, 6 ★1 C2 :
( )3
7, 9, 11

N: 2, 4, 40 A ★2 With C2 External Internal
No-Spring Choke Pilot Drain
(3, 7) ★1 (Omit if not required)

2 A★2 B★2

B: 2, 4, 40
(3, 7) ★1 (Omit if not required)
None: Spring Offset C1C2 :
Standard
Type H: 2, 4, 40 With C1 &
C2 Choke
S: Pressure Centred 60, 10, 12
Shock- 06 3 ( )3, 5, 6 ★1 ( )Omit if not
less C: required
Type 7, 9, 11
Spring Centred

N: 2, 4, 40 A ★2
No-Spring (3, 7) ★1
(Omit if not required)

10 2

B: 2, 4, 40 A★2 B★2

Spring Offset (3, 7) ★1 (Omit if not required)

Note: In spool type “3”, “5”, “6”, “60”, and “7”, the combination applicable between pilot system and drain system is as described in the table below.

Pilot Connection Drain Connection Care in Application
Internal Pilot
External Pilot (E) External Drain Hold back pressure in the tank line so that the difference between
pilot pressure and drain pressure is always more than minimum
Internal Drain (T) required pilot pressure.
External Drain
Combination is not applicable
Internal Drain (T)
No restrictions in the combination on us

382 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

-R2 -A100 -C -H -N -53 - -L

Spool Control ★3 Coil Manual Bult-in Type of Elec- Design Design Models with
Modification Type Override of Orifice for trical Conduit Number Standard Reverse Mtg.
(Omit if not required) Pilot Valve Pilot Line Connection of Solenoid

AC: 14 None:
A100 , A200 Japanese
A120 , A240
Standard L
DC:
D12 , D24 "JIS" (Omit if not required)
D48
R2 : None: 90:
With Stroke AC → DC Terminal
Adjustment, R100 , R200 None : Box Type 14 N.
Both Ends Manual American
Override E
RA : Pin Design
With Stroke
Adjustment, Standard L
Port "A" End
(Omit if not required)
RB :
With Stroke None:
Adjustment,
Port "B" End Japanese Solenoid Controlled
Pilot Operated Directional Valves
R2 : With Stroke Adj., Standard
Both Ends
AC: C: 52 "JIS" &
RA : With Stroke Adj., A100 , A200 Push European
Port "A" End A120 , A240 Button &
Lock Nut Design
RB : With Stroke Adj., DC:
Port "B" End D12 , D24 N: Standard L
D48 Push-in
P2 : With Pilot Piston, Connector (Omit if not required)
Both Ends AC → DC Type
R100 , R200 H: 80:
PA : With Pilot Piston, Refer to ★5 N1 : European
Port "A" End Push-in ★4 53 Design
Connector Standard
PB : With Pilot Piston, with (Applicable
Port "B" End Indicator only for
Light DSHG-01)

90:

N.

43 American L

Design (Omit if not required)

Standard

★1. Shekless type (S-DSHG) are not available for spool type marked ( ).
★2. As for the details of the valve using the neutral position and the side position (either SOL a or SOL b side), please refer to page 391.

Furthermore, the spool types other than “2”, “4”, “40” (3, 7) are also available.
★3. In spool-spring arrangement “H” (Pressure centred models), the valves with stroke adjustment (R*) and pilot-piston (P*) are not available.
★4. NI stands for Plug-in connector with solenoid indicator light. NI is not available for R-type solenoids.
★5. In spool-spring arrangement “H” (pressure centred models), in case the pilot pressure is more than 10 MPa (1450 PSI), please specify that the

valve should have the built-in orifice to the pilot line.

In the table above, the symbols and numbers highlighted with shade represent the optional extras.
The valves with model number having such optional extras are handles as options, therefore
please confirm the time of delivery with us before ordering.

Solenoid Controlled Pilot Operated Directional Valves 383

Sub-plates

Valve Japanese Standard "JIS" European Design Standard N. American Design Standard
Model
Numbers Sub-plate Thread Approx. Sub-plate Thread Approx. Sub-plate Thread Approx.
Model Numbers Size Mass Model Numbers Size Mass Model Numbers Size Mass

kg (1bs.) kg (1bs.) kg (1bs.)

DSGM-01-31 Rc 1/8 0.8 (1.8) DSGM-01-3080 1/8 BSP.F 0.8 (1.8) DSGM-01-3090 1/8 NPT 0.8 (1.8)

DSHG-01 DSGM-01X-31 Rc 1/4 0.8 (1.8) DSGM-01X-3080 1/4 BSP.F 0.8 (1.8) DSGM-01X-3090 1/4 NPT 0.8 (1.8)

DSGM-01Y-31 Rc 3/8 0.8 (1.8) DSGM-01Y-3090 3/8 NPT 0.8 (1.8)

DSGM-03-40 Rc 3/8 3.0 (6.6) DSGM-03-2180 3/8 BSP.F 3.0 (6.6) DSGM-03-2190 3/8 NPT 3.0 (6.6)

DSGM-03X-40 Rc 1/2 3.0 (6.6) DSGM-03X-2180 1/2 BSP.F 3.0 (6.6) DSGM-03X-2190 1/2 NPT 3.0 (6.6)
DSHG-03 Rc 3/4 4.7 (10.4) DSGM-03Y-2180 3/4 BSP.F 4.7 (10.4) DSGM-03Y-2190 3/4 NPT 4.7 (10.4)

DSGM-03Y-40

DHGM-03Y-10 Rc 3/4 4.7 (10.4) DHGM-03Y-1080 3/4 BSP.F 4.7 (10.4) DHGM-03Y-1090 3/4 NPT 4.7 (10.4)

DHGM-04-20 Rc 1/2 4.4 (9.7) DHGM-04-2080 1/2 BSP.F 4.4 (9.7) DHGM-04-2090 1/2 NPT 4.4 (9.7)
DSHG-04

DHGM-04X-20 Rc 3/4 4.1 (9.0) DHGM-04X-2080 3/4 BSP.F 4.1 (9.0) DHGM-04X-2090 3/4 NPT 4.1 (9.0)

DHGM-06-50 Rc 3/4 7.4 (16.3) DHGM-06-5080 3/4 BSP.F 8.5 (18.7) DHGM-06-5090 3/4 NPT 7.4 (16.3)
DSHG-06

DHGM-06X-50 Rc 1 7.4 (16.3) DHGM-06X-5080 1 BSP.F 8.5 (18.7) DHGM-06X-5090 1 NPT 7.4 (16.3)

DHGM-10-40 Rc 1-1/4 21.5 (47.4) DHGM-10-4080 1-1/4 BSP.F 21.5 (47.4) DHGM-10-4090 1-1/4 NPT 21.5 (47.4)
DSHG-10
DHGM-10X-40 Rc 1-1/2 21.5 (47.4) DHGM-10X-4080 1-1/2 BSP.F 21.5 (47.4) DHGM-10X-4090 1-1/2 NPT 21.5 (47.4)

DSGM-03 is available only for Internal pilot-Internal drain type (Use DHGM-03Y for other valves).
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.

Mounting Bolt

Model Name Japanese Standard "JIS" Mouting Bolt Qty. Tightening Torque
Numbers European Design Standard Nm (in. 1bs.)
N. American Design Standard
DSHG-01 Mtg. Bolt Kit 3 MBK-01-01-30 1 1 set 5 - 6 (43 - 52)
MBK-01-02-30 2 MBK-01-01-3090 1
DSHG-03 Soc. Hd. Cap Screw MBK-01-02-3090 2 4 12 - 15 (104 - 130)
M6 35 Lg. 1/4-20 UNC 1-3/4 Lg. 2 12 - 15 (104 - 130)
(S-)DSHG-04 Soc. Hd. Cap Screw 1/4-20 UNC 1-3/4 Lg. 4 58 - 72 (504 - 625)
M6 45 Lg. 3/8-16 UNC 2 Lg. 6 100 - 123 (868 - 1068)
(S)-DSHG-06 Soc. Hd. Cap Screw M10 50 Lg. 1/2-13 UNC 2-1/2 Lg. 6 473 - 585 (4106 - 5078)
(S)-DSHG-10 Soc. Hd. Cap Screw 3/4-10 UNC 3 Lg.
M12 60 Lg.
M20 75 Lg.

1. For Internal Pilot-Internal Drain.
2. For External Pilot or External Drain.
3. Mounting bolt kit is common to that of 01 series modular valves.

Refer to figure below for the dimensions of bolt kit.

Stud Bolt

"B" Thd.
Both Ends

9 9
(.35) (.35)

A 4
(.16)
Nut DIMENSIONS IN
MILLIMETRES (INCHES)

"B" Thd.

8.5 Dia. Model Numbers A mm (In.) "B" Thd.
(.33) MBK-01-01-30 94 (3.70) M5
MBK-01-02-30 134 (5.28)
MBK-01-01-3090 94 (3.70) No.10-24 UNC
MBK-01-02-3090 134 (5.28)
9
(.35)

15
(.59)

384 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Options Pressure Centred Models (3H )

Models with Pilot Choke Adjustment The pressure centered type can be used when the
returning of the main spool to the neutral position is
When the adjustment screw is turned clockwise, required to be firmily.
changeover speed of the main spool becomes slow. In
case of the spring centred valves in particular, making Graphic Symbols (Ex.: External Pilot-External Drain)
slow of the returning speed of the main spool to the
neutral position is possible with a C2 choke valve.
These choke valves can be used in combination with the
valves of spring centred, no-spring, offset, pressure
centred and the valves with stroke adjustment.

(Only for 3H6, 3H60)

Graphic Symbols (Ex.: Spring Centred) AB AB
PT PT
DSHG-01,06,10 C2 Choke a b a b
Y V Y VX

X

C1 Choke b a Models with Stroke Adjustment (R2, RA, RB) E

P Y When the adjustment screw is screwed in , the main
T spool stroke becomes short and flow rate reduces.

Graphic Symbols (Ex.: Spring Centred)

AB "R2" Models

DSHG-03, 04 AB
a
C2 Choke Solenoid Controlled
YP T Pilot Operated Directional Valves
b
"RA" Models
a b

C1 Choke

Y AB b
P a

T YP T

AB "RB" Models

AB b
a
Models with Pilot Piston(P2, PA, PB)
YP T
The valves with a pilot piston can be used when the high
speed changeover of the main spool is required. Additional Mass of Options
However, please not that in case of spring centered
valves, there is no change in the returning speed of the Add the mass described below to the mass of standard
main spool to the neutral position even with the pilot models on page 381, if options are required.
piston.
kg (1bs.)
Graphic Symbols (Ex.: Spring Centred)
Model with Pilot Models with Models with
Choke Adj.
"P2" Models Model Pilot Piston Stroke Adj.
Numbers C1, C2 C1C2
a AB P2 PA P2 PA
W YP T PB PB
b
V DSHG-03 0.65(1.4) 1.3(2.9) 0.6(1.3) 0.3 (.7)

(S-)DSHG-04 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5(1.1)

(S-)DSHG-06 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5(1.1) 1.2(2.6) 06(1.3)

"PA" Models (S-)DSHG-10 0.65(1.4) 1.3(2.9) 3.6(7.9) 1.8(4.0) 3.7(8.2) 1.85(4.1)

a AB b Options on Pilot Valve
YP T V
The same options to DSG-01 series valves are available.
"PB" Models b Please refer to page 345 for the details.

a AB
W YP T

Solenoid Controlled Pilot Operated Directional Valves 385

List of Spool Functions and Maxmum Flow (DSHG-01)

Three Positions Two Positions

Spring Centred Spring Centred

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow
L /min (U.S.GPM) L /min (U.S.GPM)
Spool Type AB AB
ab 7 MPa 14 MPa 21 MPa 7 MPa 14 MPa 21 MPa
(1020 PSI) (2030 PSI) (3050 PSI) b (1020 PSI) (2030 PSI) (3050 PSI)
Y PT
Y PT
Model Numbers
Model Numbers

"2" DSHG-01-3C2 40 (10.6) 40 (10.6) 40 (10.6) DSHG-01-2B2 40 (10.6) 40 (10.6) 40 (10.6)

"3" DSHG-01-3C3 40 (10.6) 40 (10.6) 40 (10.6) DSHG-01-2B3 40 (10.6) 40 (10.6) 40 (10.6)

"4" DSHG-01-3C4 40 (10.6) 40 (10.6) 40 (10.6) DSHG-01-2B4 40 (10.6) 40 (10.6) 40 (10.6)

"40" DSHG-01-3C40 40 (10.6) 40 (10.6) 40 (10.6) DSHG-01-2B40 40 (10.6) 40 (10.6) 40 (10.6)

"5" DSHG-01-3C5 40 (10.6) 40 (10.6) 40 (10.6)

"60" DSHG-01-3C60 40 (10.6) 40 (10.6) 40 (10.6)

"7" DSHG-01-3C7 40 (10.6) 40 (10.6) 40 (10.6) DSHG-01-2B7 40 (10.6) 40 (10.6) 40 (10.6)

"9" DSHG-01-3C9 40 (10.6) 40 (10.6) 40 (10.6)

"10" DSHG-01-3C10 40 (10.6) 40 (10.6) 40 (10.6)

"11" DSHG-01-3C11 40 (10.6) 40 (10.6) 40 (10.6)

"12" DSHG-01-3C12 40 (10.6) 40 (10.6) 40 (10.6)

Notes ) 1. Max. flow shows value at pilot pressure more than 1 MPa (150 PSI) AB
PT
2. Max. flow in the table above represents the value in the flow condition of P A B T (or P B
A T) as shown in the circuit diagram right.

In case the valve is used in the condition that either A or B port is blocked, the maximum flow differs
according to a hydraulic circuit, therefore, please consult us for details.

a b

386 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

List of Spool Functions and Maxmum Flow (DSHG-03)

Three Positions

Spring Centred

Spool Type Graphic Symbol Maximum Flow
"2" L /min (U.S.GPM)
AB
ab 7 MPa 14 MPa 25 MPa
(1020 PSI) (2030 PSI) (3630 PSI)
Y PT
85 (22.5) 60 (15.9)
Model Numbers 160 (42.3)

DSHG-03-3C2 160 (42.3) 95 (25.1)

"3" DSHG-03-3C3 160 (42.3) 160 (42.3) 160 (42.3)

"4" DSHG-03-3C4 160 (42.3) 85 (22.5) 60 (15.9)

160 (42.3) 95 (25.1)

"40" DSHG-03-3C40 160 (42.3) 85 (22.5) 60 (15.9)

160 (42.3) 95 (25.1) E

"5" DSHG-03-3C5 160 (42.3) 85 (22.5) 60 (15.9)
160 (42.3) 95 (25.1)

"60" DSHG-03-3C60 160 (42.3) 160 (42.3) 125 (33.0)

160 (42.3)

"7" DSHG-03-3C7 160 (42.3) 85 (22.5) 60 (15.9)

160 (42.3) 95 (25.1)

"9" DSHG-03-3C9 160 (42.3) 85 (22.5) 60 (15.9) Solenoid Controlled
Pilot Operated Directional Valves
160 (42.3) 95 (25.1)

"10" DSHG-03-3C10 160 (42.3) 85 (22.5) 60 (15.9)

160 (42.3) 95 (25.1)

"11" DSHG-03-3C11 160 (42.3) 85 (22.5) 60 (15.9)

160 (42.3) 95 (25.1)

"12" DSHG-03-3C12 160 (42.3) 85 (22.5) 60 (15.9)

160 (42.3) 95 (25.1)

Two Positions

No-Spring Spring Offset

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow

AB L /min (U.S.GPM) AB L /min (U.S.GPM)
a
Spool Type b 7 MPa 14 MPa 25 MPa b 7 MPa 14 MPa 25 MPa
(1020 PSI) (2030 PSI) (3630 PSI) (1020 PSI) (2030 PSI) (3630 PSI)
"2" Y PT Y PT
"3" 85 (22.5) 85 (22.5)
"4" Model Numbers 160 (42.3) 160 (42.3) Model Numbers 160 (42.3) 160 (42.3)
"40"
"7" DSHG-03-2N2 160 (42.3) DSHG-03-2B2 160 (42.3)
85 (22.5) 85 (22.5)
DSHG-03-2N3 160 (42.3) 160 (42.3) DSHG-03-2B3 160 (42.3) 160 (42.3)
160 (42.3) 160 (42.3)
DSHG-03-2N4 85 (22.5) DSHG-03-2B4 85 (22.5)
160 (42.3) 160 (42.3) 160 (42.3) 160 (42.3)
DSHG-03-2N40 160 (42.3) DSHG-03-2B40 160 (42.3)
85 (22.5) 85 (22.5)
DSHG-03-2N7 160 (42.3) 160 (42.3) DSHG-03-2B7 160 (42.3) 160 (42.3)
160 (42.3) 160 (42.3)
85 (22.5) 85 (22.5)
160 (42.3) 160 (42.3) 160 (42.3) 160 (42.3)
160 (42.3) 160 (42.3)

Notes:1. The relation between max. flow and pilot pressure in the table Pilot Pressure at 0.7 MPa (100 PSI).
above is as shown below. Pilot Pressure at 1 MPa (150 PSI).

(Example)

Maximum flow rate is constant regardless of pilot pressure. 85 (22.5)
Pilot Pressure more than 0.7 MPa (100 PSI). 160 (42.3)

160 (42.3)

2. Max. flow in the table above represents the value in the flow AB
condition of P A B T (or P B A T) as shown ab
in the circuit diagram right.
In case the valve is used in the condition that either A or B port PT
is blocked, the maximum flow differs according to a hydraulic
circuit, therefore, please consult us for details.

Solenoid Controlled Pilot Operated Directional Valves 387

List of Spool Functions and Maxmum Flow (DSHG-04/S-DSHG-04)

Three Positions

Spring Centred

Graphic Symbol Maximum Flow
L /min (U.S.GPM)
Spool Type a AB b
"2" Y PT

Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

DSHG-04-3C2 300 (79.3) 300 (79.3) 200 (52.8) 145 (38.3)

(S-)DSHG-04-3C2 300 (79.3) 250 (66.1) 120 (31.7) 110 (29.1)

"3" DSHG-04-3C3 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)

DSHG-04-3C4 300 (79.3) 300 (79.3) 250 (66.1) 165 (43.6)
"4"

(S-)DSHG-04-3C4 300 (79.3) 300 (79.3) 140 (37.0) 110 (29.1)
DSHG-04-3C40 300 (79.3) 300 (79.3) 200 (52.8) 145 (38.3)

"40"
(S-)DSHG-04-3C40 300 (79.3) 250 (66.1) 120 (31.7) 110 (29.1)

"5" DSHG-04-3C5 250 (66.1) 250 (66.1) 245 (64.7) 245 (64.7)

"6" DSHG-04-3C6 300 (79.3) 260 (68.7) 245 (64.7) 235 (62.1)
DSHG-04-3C60

"60" 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
(S-)DSHG-04-3C60

"7" DSHG-04-3C7 300 (79.3) 300 (79.3) 200 (52.8) 145 (38.3)

"9" DSHG-04-3C9 300 (79.3) 300 (79.3) 280 (74.0) 250 (66.1)
DSHG-04-3C10 300 (79.3) 300 (79.3) 200 (52.8) 150 (39.6)

"10"
(S-)DSHG-04-3C10 300 (79.3) 250 (66.1) 120 (31.7) 110 (29.1)

"11" DSHG-04-3C11 300 (79.3) 260 (68.7) 160 (42.3) 140 (37.0)
DSHG-04-3C12 300 (79.3) 280 (74.0) 170 (44.9) 135 (35.7)

"12"
(S-)DSHG-04-3C12 300 (79.3) 250 (66.1) 120 (31.7) 110 (29.1)

Two Positions

No-Spring Spring Offset

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow
L /min (U.S.GPM) L /min (U.S.GPM)
AB AB
a 10 MPa 16 MPa 25 MPa 31.5 MPa
Spool Type b b (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

Y PT Y PT

Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

"2" (S-)DSHG-04-2N2 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) (S-)DSHG-04-2B2 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)

"3" DSHG-04-2N3 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) DSHG-04-2B3 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)

"4" (S-)DSHG-04-2N4 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) (S-)DSHG-04-2B4 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)

"40" (S-)DSHG-04-2N40 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) (S-)DSHG-04-2B40 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)

"7" DSHG-04-2N7 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) DSHG-04-2B7 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)

Notes:1. Max flow described above shown value at pilot pressure more than 0.8 MPa (120 PSI). AB
ab
2. Max. flow in the table above represents the value in the flow condition of P A B T (or
P B A T) as shown in the circuit diagram right. PT
In case the valve is used in the condition that either A or B port is blocked, the maximum flow
differs according to a hydraulic circuit, therefore, please consult us for details.

388 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

List of Spool Functions and Maxmum Flow (DSHG-06/S-DSHG-06)

Three Positions

Spring Centred Pressure Centred

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow
L /min (U.S.GPM) L /min (U.S.GPM)
Spool Type AB b AB
"2" a ab

Y PT Y PT V

Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

(S-)DSHG-06-3C2 500 (132) 500 (132) 410 (108) 310 (81.9) (S-)DSHG-06-3H2 500 (132) 500 (132) 500 (132) 420 (111)

500 (132) 500 (132) 500 (132)

"3" DSHG-06-3C3 500 (132) 500 (132) 460 (122) 370 (97.8) DSHG-06-3H3 500 (132) 500 (132) 500 (132) 500 (132)

"4" (S-)DSHG-06-3C4 500 (132) 500 (132) 410 (108) 310 (81.9) (S-)DSHG-06-3H4 500 (132) 500 (132) 500 (132) 420 (111)

500 (132) 500 (132) 500 (132)

"40" (S-)DSHG-06-3C40 500 (132) 500 (132) 410 (108) 310 (81.9) 500 (132) 500 (132) 420 (111)
(S-)DSHG-06-3H40 500 (132)
500 (132) 500 (132) 500 (132)

470 (124) E
"5" DSHG-06-3C5 500 (132) 500 (132) 425 (112) 350 (92.5) DSHG-06-3H5 500 (132) 500 (132) 500 (132)

500 (132)

420 (111)
"6" DSHG-06-3C6 475 (125) 390 (103) 300 (79.3) 230 (60.8) DSHG-06-3H6 500 (132) 500 (132) 500 (132)

500 (132)

420 (111)
"60" (S-)DSHG-06-3C60 475 (125) 420 (111) 340 (89.8) 280 (74.0) (S-)DSHG-06-3H60 500 (132) 500 (132) 500 (132)

500 (132)

"7" DSHG-06-3C7 500 (132) 500 (132) 450 (119) 360 (95.1) DSHG-06-3H7 500 (132) 500 (132) 500 (132) 500 (132)

"9" DSHG-06-3C9 500 (132) 500 (132) 450 (119) 360 (95.1) DSHG-06-3H9 500 (132) 500 (132) 500 (132) 500 (132) Solenoid Controlled
Pilot Operated Directional Valves
500 (132) 500 (132)

"10" (S-)DSHG-06-3C10 500 (132) 500 (132) 410 (108) 310 (81.9) (S-)DSHG-06-3H10 500 (132) 500 (132) 500 (132) 460 (122)

500 (132) 500 (132) 500 (132)

"11" DSHG-06-3C11 500 (132) 500 (132) 410 (108) 310 (81.9) DSHG-06-3H11 500 (132) 500 (132) 500 (132) 460 (122)

500 (132) 500 (132) 500 (132)

"12" (S-)DSHG-06-3C12 500 (132) 500 (132) 410 (108) 310 (81.9) (S-)DSHG-06-3H12 500 (132) 500 (132) 500 (132) 460 (122)

500 (132) 500 (132) 500 (132)

Two Positions

No-Spring Spring Offset

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow
L /min (U.S.GPM)
Spool Type AB b AB L /min (U.S.GPM)
a b
10 MPa 16 MPa 25 MPa 31.5 MPa
Y PT Y PT (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

"2" (S-)DSHG-06-2N2 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B2 500 (132) 500 (132) 500 (132) 500 (132)

"3" DSHG-06-2N3 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B3 500 (132) 500 (132) 500 (132) 500 (132)

"4" (S-)DSHG-06-2N4 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B4 500 (132) 500 (132) 500 (132) 500 (132)

"40" (S-)DSHG-06-2N40 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B40 500 (132) 500 (132) 500 (132) 500 (132)

"7" DSHG-06-2N7 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B7 500 (132) 500 (132) 500 (132) 500 (132)

Notes:1. The relation between max. flow and pilot pressure in the table above is as shown
below.

(Example) Pilot Pressure at 0.8 MPa (120 PSI).
In case pressure centred models, pilot pressure
Maximum flow rate is constant regardless of pilot pressure. 500 (132) 410 (108) is more than 1 MPa (150 PSI)
Pilot Pressure more than 0.8 MPa (120 PSI). 500 (132)
In case pressure centred models, pilot pressure is more than Pilot Pressure at 1.5 MPa (220 PSI).
1 MPa (150 PSI).

2. Max. flow in the table above represents the value in the flow condition of P A AB
B T (or P B A T) as shown in the circuit diagram right. ab
In case the valve is used in the condition that either A or B port is blocked, the
maximum flow differs according to a hydraulic circuit, therefore, please consult us PT
for details.

Solenoid Controlled Pilot Operated Directional Valves 389

List of Spool Functions and Maxmum Flow (DSHG-010/S-DSHG-10)

Three Positions

Spring Centred Pressure Centred

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow
L /min (U.S.GPM) L /min (U.S.GPM)
Spool Type AB b AB
a ab

Y PT Y PT V

Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

"2" (S-)DSHG-10-3C2 1100 (291) 1100 (291) 950 (251) 750 (198) (S-)DSHG-10-3H2 1100 (291) 1100 (291) 1100 (291) 970 (256)

1100 (291) 1100 (291) 1100 (291)

1050 (277)
"3" DSHG-10-3C3 1100 (291) 1100 (291) 1060 (280) 895 (236) DSHG-10-3H3 1100 (291) 1100 (291) 1100 (291)

1100 (291)

"4" (S-)DSHG-10-3C4 1100 (291) 1100 (291) 950 (251) 750 (198) 970 (256)
(S-)DSHG-10-3H4 1100 (291) 1100 (291) 1100 (291)
1100 (291) 1100 (291) 1100 (291)

"40" (S-)DSHG-10-3C40 1100 (291) 1100 (291) 950 (251) 750 (198) (S-)DSHG-10-3H40 1100 (291) 1100 (291) 1100 (291) 970 (256)

1100 (291) 1100 (291) 1100 (291)

1000 (264)
"5" DSHG-10-3C5 1100 (291) 1100 (291) 980 (259) 850 (225) DSHG-10-3H5 1100 (291) 1100 (291) 1100 (291)

1100 (291)

970 (256)
"6" DSHG-10-3C6 1050 (277) 880 (232) 700 (185) 570 (151) DSHG-10-3H6 1100 (291) 1100 (291) 1100 (291)

1100 (291)

970 (256)
"60" (S-)DSHG-10-3C60 1050 (277) 940 (248) 785 (207) 680 (180) (S-)DSHG-10-3H60 1100 (291) 1100 (291) 1100 (291)

1100 (291)

"7" DSHG-10-3C7 1100 (291) 1100 (291) 1040 (275) 870 (230) DSHG-10-3H7 1100 (291) 1100 (291) 1100 (291) 1100 (291)

1100 (291) 1100 (291)

"9" DSHG-10-3C9 1100 (291) 1100 (291) 1040 (275) 870 (230) DSHG-10-3H9 1100 (291) 1100 (291) 1100 (291) 1100 (291)

"10" (S-)DSHG-10-3C10 1100 (291) 1100 (291) 950 (251) 750 (198) (S-)DSHG-10-3H10 1100 (291) 1100 (291) 1100 (291) 1060 (280)

1100 (291) 1100 (291) 1100 (291)

"11" DSHG-10-3C11 1100 (291) 1100 (291) 950 (251) 750 (198) DSHG-10-3H11 1100 (291) 1100 (291) 1100 (291) 1060 (280)

1100 (291) 1100 (291) 1100 (291)

"12" (S-)DSHG-10-3C12 1100 (291) 1100 (291) 950 (251) 750 (198) (S-)DSHG-10-3H12 1100 (291) 1100 (291) 1100 (291) 1060 (280)

1100 (291) 1100 (291) 1100 (291)

Two Positions

No-Spring Spring Offset

Graphic Symbol Maximum Flow Graphic Symbol Maximum Flow
L /min (U.S.GPM)
Spool Type AB b AB L /min (U.S.GPM)
a b
10 MPa 16 MPa 25 MPa 31.5 MPa
Y PT Y PT (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

"2" (S-)DSHG-10-2N2 1100 (291) 1100 (291) 1100 (291) 1100 (291) (S-)DSHG-10-2B2 1100 (291) 1100 (291) 1100 (291) 1100 (291)

"3" DSHG-10-2N3 1100 (291) 1100 (291) 1100 (291) 1100 (291) DSHG-10-2B3 1100 (291) 1100 (291) 1100 (291) 1100 (291)

"4" (S-)DSHG-10-2N4 1100 (291) 1100 (291) 1100 (291) 1100 (291) (S-)DSHG-10-2B4 1100 (291) 1100 (291) 1100 (291) 1100 (291)

"40" (S-)DSHG-10-2N40 1100 (291) 1100 (291) 1100 (291) 1100 (291) (S-)DSHG-10-2B40 1100 (291) 1100 (291) 1100 (291) 1100 (291)

"7" DSHG-10-2N7 1100 (291) 1100 (291) 1100 (291) 1100 (291) DSHG-10-2B7 1100 (291) 1100 (291) 1100 (291) 1100 (291)

Notes ) 1. The relation between max. flow and pilot pressure in the table above Pilot Pressure at 1 MPa (150 PSI).
is as shown below. Pilot Pressure at 1.5 MPa (220 PSI).

(Example)

Maximum flow rate is constant regardless of pilot pressure. 1040 (275)
1100 (291)
1100 (291)
Pilot Pressure more than 1 MPa (150 PSI).

2. Max. flow in the table above represents the value in the flow condition AB
of P A B T (or P B A T) as shown in the circuit ab
diagram right.
In case the valve is used in the condition that either A or B port is PT
blocked, the maximum flow differs according to a hydraulic circuit,
therefore, please consult us for details.

390 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Reverse Mounting of Solenoid.

In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b
position (side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in
the reverse position - SOL a side - is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B A and 2B B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.

AB SOL b AB SOL a
YPT a APB
b APB

XA B PTY XA B

Standard Mtg. of Solenoid Reverse Mtg. of Solenoid ("L")

Valves Using Neutral Position and Side Position. (Special Two position Valve) E

Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B).

(Example) In case of Spool Type "2"

Neutral Position

SOL. a Energised SOL. b Energised

Position Position

AB

a b

2B2A Y PT 2B2B Solenoid Controlled
b Pilot Operated Directional Valves
AB AB

b

YPT Y PT

"A": Use of Neutral and "B": Use of Neutral and
SOL. a Energised SOL. b Energised
Position Position

Graphic Symbols Graphic Symbols Graphic
Symbols
Model Numbers Standard Reverse Model Numbers Standard Reverse Model Numbers
Mtg. Mtg. Type Mtg. Mtg. Type Standard
04 04 04 Mtg.
DSHG-06-2B A DSHG-06-2B B AB DSHG-06-2N A
AB ba AB AB b a AB b
10 Y PT PT Y 10 Y PT 10 a
(S-)DSHG- -2B2A (S-)DSHG- -2B2B PT Y
Y PT

(S-)DSHG- -2N2A

DSHG- -2B3A DSHG- -2B3B DSHG- -2N3A

(S-)DSHG- -2B4A (S-)DSHG- -2B4B (S-)DSHG- -2N4A

(S-)DSHG- -2B40A (S-)DSHG- -2B40B (S-)DSHG- -2N40A

DSHG- -2B5A DSHG- -2B5B DSHG- -2N5A

DSHG- -2B6A DSHG- -2B6B DSHG- -2N6A

(S-)DSHG- -2B60A (S-)DSHG- -2B60B (S-)DSHG- -2N60A

DSHG- -2B7A DSHG- -2B7B DSHG- -2N7A

DSHG- -2B9A DSHG- -2B9B DSHG- -2N9A

(S-)DSHG- -2B10A (S-)DSHG- -2B10B (S-)DSHG- -2N10A

DSHG- -2B11A DSHG- -2B11B DSHG- -2N11A

(S-)DSHG- -2B12A (S-)DSHG- -2B12B (S-)DSHG- -2N12A

Solenoid Controlled Pilot Operated Directional Valves 391

Pressure Drop
Pressure drop curves based on viscosity of 35 mm 2/s (164 SSU) and specific gravity of 0.850.

DSHG-01

DSHG-01

Pressure Drop P PSI MPa 1 Spool Pressure Drop Spool Pressure Drop
200 1.4 2 Type Curve Numbers Type Curve Numbers

160 1.2 P AB TP BA TP T P AB TP BA TP T

1.0 3 2 3232 7 3232
120 0.8
4 3 42422 9 4242
80 0.6
4 3232 10 3 2 3 2

0.4 40 3 2 3 2 11 3 2 3 2
40 0.2 5 32321 12 3 2 3 2
60 3 2 3 2 1
00
0 10 20 30 40 L /min

0 24 68 10 U.S.GPM
40 Flow Rate

DSHG-03 DSHG-03

PSI MPa 12 3 Spool Pressure Drop Spool Pressure Drop
300 2.0 Type Curve Numbers Type Curve Numbers
4 P AB TP BA TP T P AB TP BA TP
Pressure Drop P 250 1.6 5 2 3344 7 3344 T
6 3 9 6364
200 55564 10 3544
1.2 11 6344
4 3546 12 3346
150
40 3 3 4 4
100 0.8

50 0.4 5 63462

0 0 80 120 160 L /min 60 3 3 4 4 1
0

0 10 20 30 40 U.S.GPM
Flow Rate

DSHG-04, S-DSHG-04 DSHG-04

PSI MPa 1 23 Spool Pressure Drop Spool Pressure Drop
4 Type Curve Numbers Type Curve Numbers
180 P AB TP BA TP T
160 1.2 5 P AB TP BA TP T 60 75772
7 5456
Pressure Drop P 120 0.8 6 2 5456 9 5456
10 5256
80 7 3 53557 11 6456
0.4 12 5455
4 5355
40
40 5 4 5 6

5 74555

0 6 53561
0 0 50 100 150 200 250 300 L /min

0 20 40 60 80 U.S.GPM

Flow Rate
S-DSHG-04

Spool Pressure Drop T Spool Pressure Drop
Type Curve Numbers Type Curve Numbers
P AB TP BA TP P AB TP BA TP T
2 2224 60 64672
4 2325 10 2224
40 2426 12 2225

392 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

DSHG-06, S-DSHG-06

1 DSHG-06
2
PSI MPa 3 Spool Pressure Drop Spool Pressure Drop
300 2.0 Type Curve Numbers Type Curve Numbers
P AB TP BA TP T
Pressure Drop P 250 1.6 4 P AB TP BA TP T 60 65671
7 6467
200 5 2 8 5 8 7 9 6567
1.2 10 8587
150 6 3 64674 11 8457
12 8587
0.8 7 4 8587
100 40 8587
5 84571
50 0.4 8 6 53541

00
0 100 200 300 400 500 L /min

0 20 40 60 80 100 120 140 U.S.GPM
Flow Rate

S-DSHG-06

Spool Pressure Drop T Spool Pressure Drop E
Type Curve Numbers Type Curve Numbers
P AB TP BA TP P AB TP BA TP T
2 6162 60 62631
4 6262 10 8587
40 8587 12 8587

DSHG-10, S-DSHG-10 Solenoid Controlled
Pilot Operated Directional Valves
12 DSHG-10
3
Pressure Drop P PSI MPa 4 Spool Pressure Drop Spool Pressure Drop
300 2.0 5 Type Curve Numbers Type Curve Numbers
200 400 600 6 P AB TP BA TP T P AB TP BA TP T
250 1.6 7 2 9698 60 85853
200 8 3 76775 7 7677
9 4 9696 9 7678
1.2 40 9698 10 9598
150 800 10001100 L /min 5 96861 11 9687
100 0.8 6 53522 12 9796

50 0.4
00
0

0 50 100 150 200 250 300 U.S.GPM
Flow Rate
S-DSHG-10

Spool Pressure Drop T Spool Pressure Drop
Type Curve Numbers Type Curve Numbers
P AB TP BA TP P AB TP BA TP T
2 8384 60 84842
4 8586 10 9598
40 9698 12 9796

For any other viscosity, multiply the factors in the table below.

mm2/s 15 20 30 40 50 60 70 80 90 100
Viscosity

SSU 77 98 141 186 232 278 324 371 417 464

Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30

For any other specific gravity (G'), the pressure drop ( P') may be obtained
from the formula right.

P' = P(G'/0.850)

Solenoid Controlled Pilot Operated Directional Valves 393

Typical Changeover Time

Changeover time varies according to oil viscosity, spool type and hydraulic circuit.

Test Conditions
Coil Type : D (Models with DC solenoids)
Voltage : Rated Voltage
Oil Viscosity : 35 mm2/s (164 SSU)

DSHG-04 DSHG-10

ms ms
150 250

100 Changeover Time 3C 200
SOL"ON"
50 2B Changeover Time 3C
SOL"OFF" SOL"ON"
150 SOL"OFF"
2N SOL"OFF" SOL"ON"

0 2B
0 5 10 15 20 25 MPa 2N SOL"ON","OFF"
100

50

0 1000 2000 3000 3600 PSI

Pilot Pressure 0
05
10 15 20 25 MPa

DSHG-06 0 1000 2000 3000 3600 PSI

ms 3C Pilot Pressure
150 SOL"ON"
Changeover Time SOL"OFF" 2B
100 SOL"ON"
2N SOL"OFF"
50

0
0 5 10 15 20 25 MPa

0 1000 2000 3000 3600 PSI

Pilot Pressure

394 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Terminal Box type: DSHG-01- - -14/1490 Mounting surface: ISO 4401-AB-03-4-A
Internal Pilot - Internal Drain

Space Needed to Remove AC :196.4 (7.73) Pressure Port "P"
Solenoid-Each End DC,R :204.4 (8.05) Cylinder Port "A"

AC :45.5 (1.79) 40.5 31 0.75
DC,R :50 (1.97) (1.59) (1.22) (.03)
32.5
AC :79.2 (3.12) (1.28)
DC,R :83.2 (3.28)

P
B

A

T

5.5 (.22) Dia. Through Solenoid Indicator Light
7 (.28) Dia. Spotface Tank Port "T"
4 Places

Cylinder Port "B"

Electrical Conduit Connection E
"C" Thd. (Both Ends)
46
(1.81) 95
(3.74)

Manual Actuator
6(.24) Dia.

128.8 SOL b SOL a
(5.07)
Nut 27 (1.06) Hex. 110.5 Double Solenoid Solenoid Controlled
(4.35) Models Only Pilot Operated Directional Valves
78
(3.07) Mounting Surface
63.5 (O-Rings Furnished)
(2.5)

48 43.5
(1.89) (1.71) 125(4.92)

AC 160.7(6.33)
DC,R 164.7(6.48)

Model Numbers "C" Thd. "D" Thd. DIMENSIONS IN
DSHG-01- - -14 G 1/2 Rc 1/4 MILLIMETRES (INCHES)
DSHG-01- - -1490 1/2 NPT 1/4 NPT

External Pilot - External Drain
External Pilot - Internal Drain
Internal Pilot - External Drain

SOL b SOL a

168.8 Double Solenoid Models Only
(6.65)
150.5 Pilot Drain Port "Y"
(5.92) "D" Thd.
118
(4.65)
103.5
(4.07)
60
(2.36)

Pilot Pressure Port "X"
"D" Thd.

For other dimensions, refer to "Internal Pilot Internal Drain".

Solenoid Controlled Pilot Operated Directional Valves 395

- -NN1-14/1480/1490 Mounting surface: ISO 4401-AB-03-4-A

Plug-in Connector Type: DSHG-01-
Internal Pilot-Internal Drain

The position of the Plug-i n connector can be changed as Cable Departure
illustrated below by loosening the lock nut. After
completion of the change, be sure to tighten the lock nut Cable Applicable:
with the torque as specified below. Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.0023 Sq. IN.)
E
H 70
(2.76)
F 32
(1.26)

63.5 D SOL b SOL a
(2.5)

C
78
(3.07)

48 Lock Nut 43.5
(1.89) (1.71)
Tightening Torque:
10.3 - 11.3 Nm (91-100 IN.lbs.) 125
(4.92)

K

J

External Pilot-External Drain DIMENSIONS IN
External Pilot-Internal Drain MILLIMETRES (INCHES)
Internal Pilot-External Drain

Pilot Drain Port "Y"
"J" Thd.

L SOL b SOL a
118
(4.65) Model Numbers "J" Thd.
60 DSHG-01- - -N -14 Rc 1/4
(2.36) DSHG-01- - -N -1480 1/4 BSP.F
103.5 D DSHG-01- - -N -1490 1/4 NPT
(4.07)

Pilot Pressure Port "X"
"J" Thd.

Model Numbers Dimensions mm (Inches)

CD E FHJ KL
27.5 (1.08)
DSHG-01- - -A -N /N1 128.5 (5.06) 53 (2.09) 27.5 (1.08) 39 (1.54) 79.2 (3.12) 196.4 (7.73) 160.7 (6.33) 168.5 (6.63)
34 (1.34)
DSHG-01- - -D -N /N1 139.5 (5.49) 64 (2.52) 39 (1.54) 83.2 (3.28) 204.4 (8.05) 164.7 (6.48) 179.5 (7.07)

DSHG-01- - -R -N 142.5 (5.61) 57.2 (2.25) 53 (2.09) 182.5 (7.19)

For other dimensions, refer to "Terminal Box Type".

396 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Terminal Box Type: DSHG-03- Mounting surface: ISO 4401-AC-05-4-A

- -14/1490 (The pilot and drain ports in accordance with the ISO original draft)

Pressure Port "P" Cylinder Port "B" Space Needed to Remove
Solenoid-Each End
Solenoid AC : 45.5(1.79) Model Numbers "C" Thd.
Indicator Light DC,R : 50(1.97) DSHG-03- - -14 G 1/2
DSHG-03- - -1490 1/2 NPT
AC 70.2 (2.76)
DC,R 74.2 (2.92)

L L' 32.5
Pilot Pressure Port "X" (1.28)
(For External Pilot Models Only) 46
(1.81)
Cylinder Port "A"
Tank Port "T" 50.8 Pilot Drain Port "Y" Manual Actuator
(2.0) (For External Drain Models Only) 6(.24) Dia.
Double Solenoid Models Only
95(3.74) 7(.28) Dia. Through, 11(.43) Dia. Spotface 4 Places Nut
1 46.5 A100 27(1.06) Hex.
(.04) (1.83) Electrical Conduit Connection
"C" Thd. (Both Ends)

E

SOL a SOL b

L L' 108.5
(4.27)

155.5
(6.12)

173.8
(6.84)

27 Solenoid Controlled
(1.06) Pilot Operated Directional Valves

Mounting Surface 58
(O-Rings Furnished) 170(6.69) (2.28)

Of the two of tank port "T", the tank port
in the left side is normally used in our
standard sub-plate, though, either side of
the tank port "T" can be used without
problem.

Plug-in Connector Type: DSHG-03- - -NN1-14/1490 DIMENSIONS IN
MILLIMETRES (INCHES)

J K Cable Departure
C Cable Applicable:
102 Outside Dia. 8-10mm(.31-.39 IN.)
(4.02) Conductor Area Not Exceeding 1.5mm2(.0023 Sq. IN.)

F

SOL a SOL b 27
(1.06)

108.5 D
(4.27)

E

170 58
(6.69) (2.28)

H Position of cable departure can be changed. For
details, refer to DSHG-01 valve on page 396.

Model Numbers C Dimensions mm (Inches)
39 (1.54) DEFH J K
DSHG-03- - -A -N /N1 39 (1.54) 53 (2.09) 173.5 (6.83) 27.5 (1.08) 182.2 (7.17) 196.4 (7.73) 47.2 (1.86)
DSHG-03- - -D -N /N1 53 (2.09) 64 (2.52) 184.5 (7.26) 27.5 (1.08)
DSHG-03- - -R -N
186.2 (7.33) 204.4 (8.05) 51.2 (2.02)
57.2 (2.25) 187.5 (7.38) 34 (1.34)

For other dimensions, refer to "Terminal Box Type".

Solenoid Controlled Pilot Operated Directional Valves 397

Terminal Box Type: (S-)DSHG-04- - -52/5290 Mounting surface:
ISO 4401-AD-07-4-A

Pressure Port "P" Pilot Pressure Port "X"
Tank Port "T" (For External Pilot Models Only)

11(.43) Dia. Through Pilot Drain Port "Y" "C" Thd.
(For External Drain Models Only)
17.5(.69) Dia. Spotface
4 Places Model Numbers

(S-)DSHG-04- - -52 G 1/2

(S-)DSHG-04- - -5290 1/2 NPT

Cylinder Port "A" 1.5
7(.28) Dia. Through (.06)
11(.43) Dia. Spotface
2 Places Cylinder Port "B"
Solenoid Indicator Light
Double Solenoid
Models Only AC Space Needed to Remove Electrical Conduit Connection
DC,R Solenoid-Each End "C" Thd. (Both Ends)
50.7(2.00)
54.7(2.15) Manual Actuator
6(.24) Dia.

Nut 27(1.06) Hex.

Mounting Surface 3(.12) Dia. Two Locating Pins
(O-Rings Furnished)

- -NN1-52/5290 DIMENSIONS IN
MILLIMETRES (INCHES)

Plug-in Connector Type: (S-)DSHG-04-

H J Cable Departure
C Cable Applicable:
102
(4.02) Outside Dia. . . . . . . 8-10 mm(.31 - .39 IN.)
Conductor Area . . . Not Exceeding 1.5 m m2 (.0023 Sq. IN.)

F

SOL a SOL b 114.5 D Position of cable
(4.51) departure can be
changed. For details,
E refer to DSHG-01
valve on page 396.

K

Model Numbers Dimensions mm (Inches)

C DE F H J K
39 (1.54) 47.2 (1.86) 45.6 (1.80)
(S-)DSHG-04- -A -N/N1 39 (1.54) 53 (2.09) 173.5 (6.83) 27.5 (1.08) 196.4 (7.73)
(S-)DSHG-04- -D -N/N1 53 (2.09) 51.2 (2.02) 49.6 (1.95)
(S-)DSHG-04- -R -N 64 (2.52) 184.5 (7.26) 27.5 (1.08)
204.4 (8.05)

57.2 (2.25) 187.6 (7.39) 34 (1.34)

For other dimensions, refer to "Terminal Box Type".

398 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Terminal Box Type: (S-)DSHG-06- - -53/5390 Mounting surface:
ISO 4401-AE-08-4-A

Solenoid Indicator Light Pressure Port "P"

Tank Port "T" Pilot Drain Port "Y"
(For External Drain Models Only)
13.5(.53) Dia. Through 50.5 255(10.04)
20(.79) Dia. Spotface (1.99) Model Numbers "C" Thd.
130.2 (S-)DSHG-06- - -53 G 1/2
6 Places 53.2 (5.13) (S-)DSHG-06- - -5390
(2.09) 1/2 NPT

LL 46.1
(1.81)

92.1
(3.63)
118
(4.65)

Pilot Pressure Port "X" 77 13
(For External Pilot Models Only) (3.03) 156 (.51)

Cylinder Port "A" (6.14) Cylinder Port "B"

AC 196.4(7.73) AC 45.5(1.79) Space Needed to Remove E
DC,R 204.4(8.05) DC,R 50(1.97) Solenoid-Each End
AC 50.7(2.00)
DC,R 46 Electrical Conduit Connection
54.7(2.15) (1.81) "C" Thd. (Both Ends)

Double Solenoid
Models Only

Manual Actuator
6(.24) Dia.
182.5(7.19)
200.8(7.91) Nut Solenoid Controlled
27(1.06) Hex. Pilot Operated Directional Valves
6 41
(.24) (1.61)
Mounting Surface AC 45.2(4.78) 6(.24) Dia. Two Locating Pins
(O-Rings Furnished) DC,R 49.2(1.94)
DIMENSIONS IN
Plug-in Connector Type: (S-)DSHG-06- - - NN1-53/5390 MILLIMETRES (INCHES)

H J Cable Departure
C Cable Applicable:
102
(4.02) Outside Dia. ...... 8-10 mm (.31 - .39 IN.)
Conductor Area ... Not Exceeding 1.5 mm2 (.0023 Sq. IN.)

F

SOL a SOL b 135.5 D Position of cable
(5.33) departure can be
changed. For details,
E refer to DSHG-01
valve on page 396.

K

Model Numbers Dimensions mm (Inches)

C DE F H JK
39 (1.54) 47.2 (1.86) 45.2 (1.78)
(S-)DSHG-06- -A -N/N1 39 (1.54) 53 (2.09) 200.5 (7.95) 27.5 (1.08) 196.4 (7.73)
(S-)DSHG-06- -D -N/N1 53 (2.09) 51.2 (2.02) 49.2 (1.94)
(S-)DSHG-06- -R -N 64 (2.52) 211.5 (8.33) 27.5 (1.08)
204.4 (8.05)

57.2 (2.25) 214.5 (8.44) 34 (1.34)

For other dimensions, refer to "Terminal Box Type".

Solenoid Controlled Pilot Operated Directional Valves 399

Terminal Box Type: (S-)DSHG-10- - -43/4390 Mounting surface:
ISO 4401-AF-10-4-A

Solenoid Indicator Light

Tank Port "T" Pressure Port "P"

Pilot Pressure Port "X" Pilot Drain Port "Y "
(For External Pilot Models Only) (For External Drain Models Only)

Y

XA B Model Numbers "C" Thd.
(S-)DSHG-10- - -43 G 1/2
114.3 (S-)DSHG-10- - -4390
(4.50) 1/2 NPT

19.6
(.77)

21.5(.85) Dia. Through Cylinder Port "B"

32(1.26) Dia. Spotface

6 Places

Cylinder Port "A"

AC 196.4(7.73) AC 45.5(1.79) Space Needed to Remove
DC,R 204.4(8.05) DC,R 50(1.97) Solenoid-Each End

AC 50.7(2.00) Electrical Conduit Connection
DC,R 54.7(2.15) "C" Thd. (Both Ends)

Two Eye Bolts M8 Manual Actuator
6(.24) Dia.

Nut 27(1.06) Hex.

XA B

Mounting Surface AC 22.2(.87) 6(.24) Dia. Two Locating Pins
(O-Rings Furnished) DC,R 26.2(1.03)

Plug-in Connector Type: (S-)DSHG-10- - - NN1-43/4390 DIMENSIONS IN
MILLIMETRES (INCHES)

H J Cable Departure
C Cable Applicable:
102 Outside Dia. ...... 8-10 mm (.31 - .39 IN.)
(4.02) Conductor Area ... Not Exceeding 1.5 mm2 (.0023 Sq. IN.)

F Position of cable
departure can be
198.5 D changed. For details,
(7.81) refer to DSHG-01
valve on page 396.
E

K

Model Numbers Dimensions mm (Inches)

C DEF H JK
39 (1.54) 47.2 (1.86) 22.2 (.87)
(S-)DSHG-10- -A -N/N1 39 (1.54) 53 (2.09) 263.5 (10.37) 27.5 (1.08) 196.4 (7.73)
(S-)DSHG-10- -D -N/N1 53 (2.09) 51.2 (2.02) 26.2(1.03)
(S-)DSHG-10- -R -N 64 (2.52) 274.5 (10.81) 27.5 (1.08)
204.4 (8.05)

57.2 (2.25) 277.5 (10.93) 34 (1.34)

For other dimensions, refer to "Terminal Box Type".

400 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Sub-plate

DHGM-03Y-10/1080/1090 120 Sub-plate "C" Thd. "D" Thd. "E" Thd. F
(4.72) Model Numbers mm (in.)
Rc 3/4 Rc 1/4
15 90 DHGM-03Y-10 3/4 BSP.F 1/4 BSP.F M6 13(.51)
(.59) (3.54) DHGM-03Y-1080 3/4 NPT 1/4 NPT

18 62 DHGM-03Y-1090
(.71) (2.44)

54 1/4-20 UNC 15(.59)
(2.13)
37.3(1.47) 11(.43) Dia. 50
4 Places (1.97)
"D" Thd. 43(1.69)
27(1.06) 80
Used only on external 42(1.65) (3.15)
pilot type valves. 16.7(.66)
To be plugged on internal 25(.98) 45
pilot type valves. (1.77)

25 22(.87) 8(.31) 3.2 10 16(.63)
(.98) (.13) (.39) 47
(1.85)
10 32.5(1.28) 21.5(.85) 6.4(.25) 12 76
(.39) (.47) (2.99)

19 110 90 46 (1.81) 11 19 P E
(.75) (4.33) (3.54) (.43) (.75) BT

70
(2.76)

6.2(.24) Dia. 19 6.2(.24) Dia. A "C" Thd.
(.75) 4 Places
"E" Thd. "F" Deep "D" Thd.
92 4 Places Used only on external
(3.62) drain type valves.
To be plugged on internal
drain type valves.

DIMENSIONS IN Sub-plate "C" Thd. "D" Thd. "E" Thd. 21.5(.85)"F" Thd.
MILLIMETRES (INCHES) Model Numbers 33(1.30)
76
DHGM-0044X -20/2080/2090 (2.99)

DHGM-04-20 Rc 1/2 Rc 1/4 Solenoid Controlled
DHGM-04X-20 Rc 3/4 Pilot Operated Directional Valves
190 M10 M6
(7.48) DHGM-04-2080 1/2 BSP.F
12(.47) DHGM-04X-2080 3/4 BSP.F 1/4 BSP.F
32.2(1.27) 166
(6.54) DHGM-04-2090 1/2 NPT 1/4 NPT 3/8-16 UNC 1/4-20 UNC
34(1.34) DHGM-04X-2090 3/4 NPT
101.6
(4.00) "E" Thd. 36 125 "C" Thd.
17(.67) Deep (1.42) (4.92) 4 Places
76.7 4 Places
(3.02) 20 90
6(.24) Dia. 2 Places (.79) (3.54)
50 17.5(.69) Dia. 19
(1.97) 4 Places (.75) 46
"F" Thd. 12(.47) Deep (1.81)
18.3(.72) 2 Places

12 16 29
(.47) (.63) (1.14)
13.1
(.52) 10.1
1.6(.06) (.40)

120 57.1 65 P
(4.72) (2.25) (2.56) X
90
96 T PX (3.54) Y T
(3.78) A BY B
71.4
(2.81)
69.8
(2.75)

55.6
(2.19)
14.2
(.56)

A

11(.43) Dia. Through 65.8 "D" Thd. 58
17.5(.69) Dia. Spotface (2.59) 2 Places (2.28)
4 Places
14.2 88.1 102
3.6(.14) Dia. (.56) (3.47) (4.02)
5(.20) Deep
2 Places 130 137.5
(5.12) (5.41)

Valve Types Pilot Pressure Port "X" Port "Y"
Used only on external pilot type
Solenoid Controlled Pilot valves. Used as drain port only on external
Operated Directional Valves To be plugged on internal pilot drain type valves.
type valves. To be plugged on internal drain
Pilot Operated Spring Centred type valves.
Directional No-spring Used
Valves Used as pilot pressure port
Spring Offset Not used (plug is not required)
Used as pilot drain port
Manually Operated Directional Valves Used as drain port

Solenoid Controlled Pilot Operated Directional Valves 401

Sub-plate

DHGM-0066X -50/5090 204 Sub-plate "C" Thd. "D" Thd. "E" Thd. F
(8.03) Model Numbers mm (in.)
12
(.47) 180 DHGM-06-50 Rc 3/4 Rc 1/4 M12 24 (.94)
(7.09)
25 DHGM-06X-50 Rc 1 26 (1.02)
(.98) 130.2
(5.13) DHGM-06-5090 3/4 NPT 1/4 NPT 1/2-13 UNC
29.4(1.16)
112.7 DHGM-06X-5090 1 NPT
(4.44)
11(.43) Dia.
94.5
(3.72) "D" Thd. (From Rear)
4 Places
77
(3.03) "E" Thd. "F" Deep
6 Places
53.2
(2.09)

5.6(.22)

116 V TP Y 46.1
(4.57) XA B (1.81)
92.1
(3.63) 73.1
74.6 (2.88)
(2.94)
96.9
(3.81)

12 17.5(.69) 17.5 11(.43) Dia. Through 34(1.34)
(.47) (.69) 17.5(.69) Dia. Spotface 35(1.38)
19.1(.75) 4 Places 50
29.5 (1.97)
7(.28) Dia. (1.16) 23(.91) Dia.
"C" Thd. (From Rear) DIMENSIONS IN
8(.31) Deep 100.8 4 Places MILLIMETRES (INCHES)
2 Places (3.97)

12.5 126.2
(.49) (4.97)

156
(6.14)

DHGM-0066X -5080

204 M12 Thd. 1/4 BSP.F Thd. D
(8.03) 24(.94) Deep 4 Places E
6 Places
12 180 F
(.47) (7.09) 50 H
J
25 130.2 (1.97)
(.98) (5.13)
35
(1.38)

134 T PY 11.9 Y P T
(5.28) V AB W (.47) W V
110 X 73.1 46.1
(4.33) 116 (2.88) BA X (1.81)
92.1 (4.57)
(3.63) 74.6
(2.94)

12 12.5 11(.43) Dia. 17.5 N 19.1
(.47) (.49) 4 Places (.69) L (.75)
K
8.9 156 24.5(.96) Dia.
(.35) (6.14) 4 Places

"C" Thd.
4 Places

Sub-plate "C" Thd. D E F Dimensions mm (Inches) L N
Model Numbers 102 (4.02) H JK 78.2 (3.08) 42.5 (1.67)
106 (4.17) 74 (2.91) 32 (1.26)
DHGM-06-5080 3/4 BSP.F 151.2 (5.95) 137.7 (5.42) 54.4 (2.14) 30.6 (1.20) 125.8 (4.95)
50 (1.97) 25 (.98) 130 (5.12)
DHGM-06X-5080 1 BSP.F 155.2 (6.11) 148 (5.83)

For other dimensions, refer to "DHGM-06 -50/5090" above.
For Uses of Port "X", "Y", "V", "W", refer to DHGM-10 on the following page.

402 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Sub-plate

DHGM-1100X -40/4080/4090 DIMENSIONS IN
MILLIMETRES (INCHES)
306.5
(12.07)

20(.79) 266.5
(10.49)

38(1.50) 190.5 7 (.28) Dia. 8 (.31) Deep
(7.50) 2 Places

168.3 "E" Thd. 34 (1.34) Deep
(6.63) 6 Places

147.6 60
(5.81) (2.36)

114.3 213
(4.50) (8.39)

76.2(3.00) F

41.3(1.63) H "C" Thd. E
4 Places

199 VT P Y 114.3 YP T
(7.83) X A BW (4.50) WB V
158.8
(6.25) A
123.8 X
(4.87)
79.4
(3.13)

20.1 28.6 35 43(1.69) "D" Thd. Solenoid Controlled
(.79) (1.13) (1.38) 4 Places Pilot Operated Directional Valves

21.8 82.5 44(1.73) 55
(.86) (3.25) (2.17)
17.5 (.69) Dia. Through
11 (.43) Dia. 234 K
4 Places (9.21) 26 (1.02) Dia. Spotface
4 Places
J
36 (1.42) Dia.

4 Places

Sub-plate "C" Thd. "D" Thd. "E" Thd. F Dimensions mm (Inches) K
Model Numbers 152 (5.98) HJ
DHGM-10-40 Rc 1-1/4 Rc 3/8 M20
DHGM-10-4080 1-1/4 BSP.F 3/8 BSP.F M20 156 (6.14) 79 (3.11) 185.5 (7.30) 120.5 (4.74)
DHGM-10-4090 1-1/4 NPT 3/8 NPT 3/4-10 UNC
DHGM-10X-40 M20 74 (2.91) 194.5 (7.66) 112.5 (4.43)
DHGM-10X-4080 Rc 1-1/2 Rc 3/8 M20
DHGM-10X-4090 1-1/2 BSP.F 3/8 BSP.F 3/4-10 UNC
1-1/2 NPT 3/8 NPT

Note: Uses of port "X", "Y", "V", and "W"

Valve Types Pilot Pres. Port "X" Port "Y" Drain Port "V" Drain Port "W"
Used only on Used as drain port only
Spring Centred, No-spring, external pilot type on external drain type Not used (plug is not required)
Spring Offset valves. valves.
Solenoid To be plugged on Used Not used
Controlled Pressure Centred internal pilot type To be plugged on Used Used
With Pilot Piston, Both Ends valves. internal drain type Not used
Pilot valves. Used (plug is required)
Operated With Pilot Piston, Used
Directional Port "A" End Used as pilot pres. port Not used Used
Valves Not used Used as pilot drain port (plug is required)
With Pilot Piston, (plug is not required)
Port "B" End Used as pilot pres. port

Spring Centred, No-spring Used as pilot pres. port Not used (plug is not required)
Used as pilot drain port
Spring Offset Not used
(plug is not required)
Pressure Centred Used Not used
Used Used
Pilot With Pilot Piston, Both Ends
Operated Not used Used
Directional With Pilot Piston, (pllug is required)
Valves Port "B" End

With Pilot Spring Centred Not used
Piston (plug is required)
Port "A" No-spring Used

End Spring Offset

Manually Operated Directional Valves Used Not used (plug is
not required)

As the thread is provided on the body, plug either port on the sub-plate or port on the body.

Solenoid Controlled Pilot Operated Directional Valves 403

Options

Models with Pilot Choke Valve

Terminal Box Type Plug-in Connector Type

DSHG-03- -C1/C2/C1C2 DSHG-03- -C1/C2/C1C2- N
N1
Fully
Extended Fully Extended
37.5 59
(1.48)(2.32) 37.5 59

(1.48) (2.32)

SOL a SOL b

SOL a SOL b A

E E
D J
C
H
H F
F

(S-)DSHG-04- -C1/C2/C1C2 (S-)DSHG-04- -C1/C2/C1C2-NN1

Fully Extended Fully Extended
59 59

(2.32) (2.32)

SOL a SOL b SOL a SOL b

E E
D J
C
H
H F
F

(S-)DSHG-1060 - -C1/C2/C1C2 (S-)DSHG-0106 - -C1/C2/C1C2-NN1

Fully Extended Fully Extended
59 59

(2.32) (2.32)

SOL a SOL b SOL a SOL b

E E
D F
H
F
H

1. "C1" Choke Adj. Screw 6 (.24) Hex. DIMENSIONS IN
2. "C2" Choke Adj. Screw 6 (.24) Hex. MILLIMETRES (INCHES)
3. Lock Nut 12 (.47) Hex.

Dimensions mm (Inches)

Model Numbers C D E FH J
DC SO L
198.8 (7.83) 180.5 (7.11) AC SO L R SOL
223.8 (8.81) 205.5 (8.09)
DSHG-03- -C1 204.8 (8.06) 186.5 (7.34) 100 (3.94) 100 (3.94) 198.5 (7.81) 209.5 (8.25) 212.5 (8.37)
DSHG-03- -C2 229.8 (9.05) 211.5 (8.33) 133.5 (5.26) 100 (3.94)
DSHG-03- -C1C2 225.8 (8.89) 207.5 (8.17) 223.5 (8.80) 234.5 (9.23) 237.5 (9.35)
(S-) DSHG-04- -C1 250.8 (9.87) 232.5 (9.15) 158.5 (6.24) 125 (4.92) 106 (4.17)
(S-) DSHG-04- -C2 288.8 (11.37) 270.5 (10.65) 106 (4.17) 106 (4.17) 204.5 (8.05) 215.5 (8.48) 218.5 (8.60)
(S-) DSHG-04- -C1C2 313.8 (12.35) 295.5 (11.63)
(S-) DSHG-06- -C1 139.5 (5.49) 127 (5.00) 229.5 (9.04) 240.5 (9.47) 243.5 (9.59)
(S-) DSHG-06- -C2 127 (5.00)
(S-) DSHG-06- -C1C2 164.5 (6.48) 131 (5.16) 225.5 (8.88) 236.5 (9.31) 239.5 (9.43)
(S-) DSHG-10- -C1 127 (5.00) 190 (7.48)
(S-) DSHG-10- -C2 190 (7.48) 250.5 (9.86) 261.5 (10.30) 264.5 (10.41)
(S-) DSHG-10- -C1C2 160.5 (6.32)
288.5 (11.36) 299.5 (11.79) 302.5 (11.91)
185.5 (7.30) 152 (5.98)
190 (7.48) 313.5 (12.34) 324.5 (12.78) 327.5 (12.89)

223.5 (8.80)

248.5 (9.78) 215 (8.46)

404 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Options Models with Stroke Adjustment
DSHG-03- -R
Fully Extended
252 (9.92)

Lock Nut 17(.67) Hex.

SOL a SOL b

35
(1.38)

Stroke Adj. Screw (Port "A" End) 99 (3.90) Stroke Adj. Screw (Port "B" End)
13 (.51) Hex. Fully Extended 13 (.51) Hex.

(S-)DSHG-04- -R Fully Extended
289 (11.38)
E

SOL a SOL b

Lock Nut 17(.67) Hex.

Stroke Adj. Screw (Port "A" End) 33 Solenoid Controlled
13 (.51) Hex. (1.30) Pilot Operated Directional Valves

93 (3.66) Stroke Adj. Screw (Port "B" End)
Fully Extended 13 (.51) Hex.

(S-)DSHG-1060- -R Fully Extended
C

SOL a SOL b

Lock Nut 24(.94) Hex.

E

Stroke Adj. Screw (Port "A" End) D Stroke Adj. Screw (Port "B" End)
17 (.67) Hex. Fully Extended 17 (.67) Hex.

Model Numbers C DE
(S-)DSHG-06- -R2 376 (14.80) 111 (4.37) 40 (1.57)
(S-)DSHG-10- -R2 558 (21.97) 164.5 (6.48) 65 (2.56)

DIMENSIONS IN
MILLIMETRES (INCHES)

Pressure Centred Model s Models with Pilot Piston

(S-)DSHG- 0160-3H C (S-)DSHG- 0106- -P

C

SOL a SOL b SOL a SOL b

D D

Model Numbers C D Model Numbers C D
(S-)DSHG-06-3H 306.5 (12.07) 102 (4.02) (S-)DSHG-06- -P2 323 (12.72) 84 (3.31)
(S-)DSHG-10-3H 456 (17.95) 149.5 (5.89) (S-)DSHG-10- -P2 479 (18.86) 125 (4.92)

Solenoid Controlled Pilot Operated Directional Valves 405

List of Seals and Pilot Valves
DSHG-01- - -14/1480/1490

Pipe Plug 12 15 14 17 16 8 18 12 Pipe Plug
Removed for External Drain Models
Removed for External

Pilot Models

SOL b SOL a

13

T Pipe Plug
Removed for Internal Pilot Models

13 Pipe Plug

Removed for Internal Drain Models

2 5 4 11 8 3 1 7 10 6

Note: Piece parts marked are not available
for internal pilot-internal drain type

DSHG-03- - -14/1490 15 14 17 16

Pipe Plug Pipe Plug

13 Removed for Internal 13 Removed for Internal

Pilot Models Drain Models

SOL a SOL b

X Y

Section X-X 12 5 4 9 1 8 3 10 7 2 6 Section Y-Y

X Y

List of Seals Pilot Valves
See page 408 for the pilot valve model numbers to be used.
DSHG-01 DSHG-03
Item Name
Part Numbers Qty. Part Numbers Qty.

7 O-Ring JASO-1018-1A 2 SO-NB-P28 2

8 O-Ring SO-NB-P9 8(4) SO-NB-A104 5

9 O-Ring SO-NB-P9 2

10 O-Ring SO-NB-P5 2 SO-NB-P9 6

Quantities in the ( ) are applicable to internal pilot-internal drain.

Note: When ordering the o-rings, please specify the seal kit number listed
in page 408. In addition to the above o-rings, o-rings for pilot
valve is included in the seal kit.
For the detail of the pilot valve o-rings, see page 359.

406 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

■ List of Seals and Pilot Valves

(S-)DSHG-04- - -52/5290
15 14 16 17

Pipe Plug Pipe Plug
Removed for Internal
11 Removed for Internal Pilot Models

Drain Models 11

SOL a SOL b

XY 12

E

XY Section Y-Y Section X-X

18 10 5 4 1 3 9 13 8 2 7

(S-)DSHG-06- - -53/5390 Solenoid Controlled
(S-)DSHG-10- - -43/4390 Pilot Operated Directional Valves

15 14 16 17 Pipe Plug Pipe Plug
Removed for Internal Removed for Internal
Pilot Models Drain Models

11 11

SOL a SOL b 21 12
12 Section X-X
21 X
Y

X

Section Y-Y 11 Pipe Plug

Y Removed for External
Drain Models
18 2 10 5 3 1 9 13 8 4 7

Note: Item 21 orifice marked is applicable to pressure centred models
(3H ) with pilot pressure more than 10 MPa (1450 PSI).

List of Seals Part Numbers (S-)DSHG-10 Qty. Pilot Valves
(S-)DSHG-06 SO-NB-P20 See page 408 for the pilot valve model numbers to
Item Name SO-NB-P14 SO-NB-P42 2 be used.
(S-)DSHG-04 SO-NB-P30 SO-NB-P65 4
SO-NB-P40 SO-NB-P14 2
8 SO-NB-P9 SO-NB-P10 2
9 SO-NB-P22

O-Ring
10 SO-NB-P34
18 SO-NB-P9

Note: When ordering the o-rings, please specify the seal kit number listed in page
408. In addition to the above o-rings, o-rings for pilot valve is included in
the seal kit.
For the detail of the pilot valve o-rings, see page 359.

Solenoid Controlled Pilot Operated Directional Valves 407

■ List of Seal Kits and Pilot Valves

Valve Model Numbers Pilot Valve Model Numbers Seal Kit Numbers

DSHG-01-3C - - -14 DSG-01-3C4- - -70 KS-DSHG-01- -14
DSHG-01-3C - -N-1480 DSG-01-3C4- -N-70 (For Internal Pilot-Internal Drain)
DSHG-01-3C - - -1490 DSG-01-3C4- - -7090

DSHG-01-2B - - -14 DSG-01-2B2- - -70-L KS-DSHG-01-ET- -14
DSHG-01-2B - -N-1480 DSG-01-2B2- -N-70-L (Except for Internal Pilot-Internal Drain)
DSHG-01-2B - - -1490 DSG-01-2B2- - -7090-L

DSHG-03-3C - - -14 DSG-01-3C4- - -70
DSHG-03-3C - - -1490 DSG-01-3C4- - -7090

DSHG-03-2B - - -14 DSG-01-2B2- - -70 KS-DSHG-03- -14
DSHG-03-2B - - -1490 DSG-01-2B2- - -7090

DSHG-03-2N - - -14 DSG-01-2D2- - -70
DSHG-03-2N - - -1490 DSG-01-2D2- - -7090

(S-)DSHG-04-3C - - -52 DSG-01-3C4- - -70
(S-)DSHG-04-3C - - -5290 DSG-01-3C4- - -7090

(S-)DSHG-04-2B - - -52 DSG-01-2B2- - -70 KS-DSHG-04- -52
(S-)DSHG-04-2B - - -5290 DSG-01-2B2- - -7090

(S-)DSHG-04-2N - - -52 DSG-01-2D2- - -70
(S-)DSHG-04-2N - - -5290 DSG-01-2D2- - -7090

(S-)DSHG-06-3C - - -53 DSG-01-3C4- - -70
(S-)DSHG-06-3C - - -5390 DSG-01-3C4- - -7090

(S-)DSHG-06-2B - - -53 DSG-01-2B2- - -70-L KS-DSHG-06- -53
(S-)DSHG-06-2B - - -5390 DSG-01-2B2- - -7090-L

(S-)DSHG-06-2N - - -53 DSG-01-2D2- - -70
(S-)DSHG-06-2N - - -5390 DSG-01-2D2- - -7090

(S-)DSHG-10-3C - - -43 DSG-01-3C4- - -70
(S-)DSHG-10-3C - - -4390 DSG-01-3C4- - -7090

(S-)DSHG-10-2B - - -43 DSG-01-2B2- - -70-L KS-DSHG-10- -43
(S-)DSHG-10-2B - - -4390 DSG-01-2B2- - -7090-L

(S-)DSHG-10-2N - - -43 DSG-01-2D2- - -70
(S-)DSHG-10-2N - - -4390 DSG-01-2D2- - -7090

Notes) 1: Fill coil type (a symbol representing current/voltage) in section marked . Likewise, in section marked , fill a symbol
representing the type of electrical conduit connection (None: Terminal Box Type, N: Plug-in Connector Type).

2: For the details of the pilot valves, see page 359 to 360.

408 Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

■ “ ” Series Shockless Type Solenoid Operated / Solenoid
Controlled Pilot Operated Directional Valves

The G-Series Solenoid Operated Directional Valves incorporate electronic G-DSG-01
circuits o enable adjustment of the spool shifting time.
A special spool shape that minimises shock is used, shocks caused by the
actuator starting and stopping, as well as vibration due to oil hammering.
The shifting time of conventional Solenoid Operated, Shockless, and
Directional Valves is constant and cannot be adjusted.
As the shifting time of the G-Series valves can be adjusted, it can be set at
an optimal level to minimise shocks to the machine.

E

1 Reduces oil hammering during spool changeover. G-DSHG-04 “ ” Series Shockless Type Solenoid Operated /
Solenoid Controlled Pilot Operated Directional Valves
Conventional Type G-Series Valve

W W

Oil Hammering No vibration
No oil leakage
Improvement Enhanced
machining
Piping Machine SOL accuracy
vibration vibration ON

SOL Solenoid Valve
ON

PT Oil leakage Large machining PT
errors

2 Reduces shock caused by acceleration and deceleration G-Series Valve

Conventional Type Slow start
Jerk at start up

No shaking

Improvement

Sudden stop, causing shock Slow stop No shaking
Shaking Still

Stopping accuracy enhanced 409

“ ” Series Shockless Type Solenoid Operated /
Solenoid Controlled Pilot Operated Directional Valves

System Diagram (Example of sink type wiring) Deceleration
Start Signal
Programmable
Controller

Shifting Signal

HALT 24 V DC
SOL a DC Power
SOL b Supply

Adj. Volume Adj. Volume "MIN" Adj. Volume "OFF ADJ"
"OFF ADJ" Output Current Check (to 0V) Adj. Volume "ON T"
Adj. Volume "OFF T"
Adj. Volume
"ON T"

Adj. Volume
"OFF T"

Relationships between SOL signals and flow patterns

Without HALT functions With HALT functions

AB AB

PT PT MIN MIN

Pattern OFF ADJ AB Pattern OFF AB
of Flow of Flow ADJ
OFF T PT Max. PT Max.
ON T (Max. 1s) ON T OFF T 60s OFF 60s
(Max. 1s) (Max. 1s) (Max. 1s) ADJ
OFF ON
OFF OFF ADJ OFF
OFF
ON ON T OFF T ON OFF ON T OFF T
(Max. 1s) (Max. 1s)
SOL a SOL a (Max. 1s) (Max. 1s)
SOL b ON OFF SOL b ON
HALT
ON
OFF

Hold for 0.1 second or longer Hold for 0.1 second or longer

The minimum adjustment volume is common for SOL a and b, and it is not possible to set a different volume for each SOL a and b individually.
If the HALT functions are not used, set the minimum adjustment volume to zero.

410 “ ” Series Shockless Type Solenoid Operated /
Solenoid Controlled Pilot Operated Directional Valves

DIRECTIONAL CONTROLS

Instructions (Example) G-DSG valve
a fully opens after the ON T duration.
Adjustment of maximum flow rate
The G-Series Solenoid Operated Directional Valves b To adjust maximum flow rates, with
cannot be adjusted for maximum flow rates. PTB
To adjust maximum flow rates, use flow control valves. "G" series solenoid operated direc-
In G-series solenoid controlled pilot operated direc- tional valves (G-DSG-01/03), flow
tional valves (G-DSHG-04/06), the maximum flow rate control valves such as throttle check
can be adjusted by use of the valve with stroke adjust- modular valves are used.
ment screw of optional extra. With "G" series solenoid controlled
pilot operated directional valves (G-
DSHG-04/06), maximum flow rates
A can be adjusted without flow control
valves but by using a model with
stroke adjustment (option).

How to use HALT functions E
The HALT functions are used to drive the actuator at a low speed to the stop position while keeping a slight flow
after OFF T. “ ” Series Shockless Type Solenoid Operated /
A flow rate (min. flow rate) during a low-speed operation can be set with the minimum adjusting volume (The minimum Solenoid Controlled Pilot Operated Directional Valves
adjusting volume is common for SOL a and b. Individual setting is not possible for SOL a and b.) When HALT signal
is on, the min. flow rate becomes zero and the actuator stops. Here, take care to keep the HALT signal on for longer
than 0.1 second. The min. flow rate gets to "0" after about 60 seconds following the OFF T. If the HALT functions
are not used, set the minimum adjusting volume to zero.
The HALT functions are not applicable to the spool function "2B7".

Flow Rate Max. 60 s If no HALT signal is set on within 60

seconds of the end of OFF T, the flow rate
decreases gradually.

0

ON OFF T MIN

SOL OFF

OFF ON OFF

HALT

Hold for 0.1 second or longer

“ ” Series Shockless Type Solenoid Operated / 411
Solenoid Controlled Pilot Operated Directional Valves


Click to View FlipBook Version