The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by Clima Shop, 2019-05-02 09:24:44

Toshiba Rezidential 2018

Toshiba Rezidential 2018

GENERAL CATALOGUE

2016 RESIDENTIAL
2017 & LIGHT

COMMERCIAL
PRODUCTS

2

Index

Residential 17

G2KVP 18
N3KVP 20
N3KV2 22
BKVG 24
BKV 26
7SKV 28
UFV 30
S3AV 36
SMUV 38
G3DV 39
N3KVP 40
N3KV2 41
UFV 42

Light Commercial 59

SP_AT(P) 62
SM_ATP 64
SM_AT8 66
SM_UTP 68
SM_MUT 70
SM_BTP 72
SM_SDT 74
SM_DT 76
SM_CTP 78
SM_KRT 80
DX COIL 82
AIR CURTAIN 84
BRANCHING KITS 86

Heating 93

Estia 96
Estia Powerful 98

Business 101

3

Toshiba Group

Toshiba was founded in 1939 by the merger of
Shibaura Seisakusho (Shibaura Engineering Works)
and Tokyo Denki (Tokyo Electric).
In 1875, Tanaka Hisashige, established Tanaka
Seisakusho as the first manufacturer of telegraph
equipment in Japan. In 1904, it was renamed
to Shibaura Seisakusho and became a major
manufacturer of heavy electrical machinery. Very
soon the company was a world industrial power.
In 1890, Hakunetsusha was founded and it was
characterized as the first producer of incandescent
electric lamps in Japan. It later diversified into the
manufacture of other consumer products and in
1899 had been renamed Tokyo Denki.
The merger of Shibaura and Tokyo Denki created
a new company, which in 1978 named Toshiba
Corporation.
Today, more than 130 years after, Toshiba Group
provided a wide range of products and services
that feature the best in innovation technologies
and the finest quality.
Toshiba is a diversified electric/electronic manufacturer
and provides a wide range of products and services
on a global basis in five business domains: Energy
& Infrastructure, Community Solutions, Healthcare
Systems & Services, Electronic Devices & Components
and Lifestyle Products & Services.

4

The Toshiba Commitment

Basic Commitment

We, the Toshiba Group companies based on our total commitment to people
and to the future, are determined to help create a higher quality of life for all
people, and to do our part, to help ensure that progress continues within the
world community.

Commitment to people

We endeavor to serve the needs of all people, especially our customers,
shareholders, and employees, by implementing forward – looking corporate
strategies while carrying out responsible and responsive business activities.
As good corporate citizens, we actively contribute to future the goals of
society.

Commitment to the future

By continually developing innovative technologies centering on the fields
of Electronics and Energy, we strive to create products and services that
enhance human life, and which lead to a thriving, healthy society. We
constantly seek new approaches that help realize the goals of the world
community, including ways to improve the global environment.

Committed to People,
Committed to the Future.

5

Toshiba Air - Conditioning Principles

Leading the innovation

Toshiba produced its first air conditioning units in the 1950’s, and
immediately worked on introducing improvements. Its role as an innovator
continued with the introduction of the rotary compressor and electronic
controls. By the 1980’s with a broad product offering, Toshiba was the first
to introduce the inverter driven unit (1981) and the twin rotary compressor
(in 1988). In 1999, Toshiba again led the industry with the launch of its
product range operating with non-ozone depleting refrigerants (R410A
and R407C).

Toshiba’s spirit of innovation continues with its relentless drive for product
and system improvements. Every year, from 1994 onward, Toshiba has
received a prestigious award for its great achievement in the industry.

Innovations for worldwide air conditioning market

2000: Revolutionary DC hybrid inverter
2003: Digital Inverter
2004: SMMS (the VRF system with the industry’s highest COP)
2006: MiNi-SMMS
2007: Super Daiseikai with Ag Plasma air purifier
2009: Estia, Air-to-Water Heat Pump
2010: SMMS-i, the next generation energy efficient VRF system
2015: SMMS-e: Expansion - Experience - Excellence - Evolution

Quality

Quality has always been Toshiba’s strength and will remain the trademark
that will differentiate Toshiba air conditioners from the competition.

Toshiba is following not only the industry regulations for quality control in
order to take all necessary certifications but has introduced even higher
internal quality standards that all products have to follow strictly during
the development and manufacture process.

Toshiba products are certified with third parties institutes for quality, safety
and performance (TUV, Eurovent, WEEE, RoHS, REACH).

This is the philosophy behind every Toshiba product.

66

Environmental Management

Toshiba has its own Environmental Preservation Manual in place that
is in line with the international standard ISO14001. It is used to ensure
field management, and conduct internal environmental audit, based
on the environmental preservation activities, in order to maintain
and continuously improve the Environmental Management System.

Corporate social responsibility

Toshiba signed the United Nations Global Compact in 2004 and since
then has implemented and promoted these basic principle concern-
ing human rights, labor, environment and anti-corruption within the
organization and towards its suppliers.
Corporate social responsibility is reviewed every year by third parties
and Toshiba has been awarded with several prizes for its success and
commitment.

7

Toshiba Air - Conditioning Solutions

Residential Residential

Toshiba was the first company to incorporate inverter technology into air Light
conditioning systems in 1981 and since then it has always maintained a Commercial
technological advantage over its competitors.
The development of the new and exclusive DC hybrid inverter system has Business
reaffirmed this ability to innovate and maintain technological leadership in
a fast-growing market.
Toshiba continuous research developed PWM technology, which is used
together with the traditional PAM control.
The application of these two distinct technologies allows total control of
performance and energy use.
Residential air conditioners have a performance range from 2.5 kW to 7.0
kW and can be installed as single system or multi system.
Regardless of which model you decide for, all Toshiba air conditioners
operate with high efficiency, ensure fresh and well filtered air and perfect
temperatures all year round.

Light commercial

Toshiba Digital and Super Digital Inverter systems deliver exceptional
operating savings in extremely compact units.
With state-of-the-art technologies, flexible controls and improved installation
Toshiba brings comfort and convenience to any business installation.
A complete range of indoor units satisfies all commercial applications:
ceiling, cassette, ducted, console, under ceiling and high-wall.
The enlargement of the range with maximum cooling capacities up to
27 kW allows to address even more commercial applications with larger
volumes.
Three TOSHIBA product lines shine with the benefits of vector IPDU inverter
technology, guaranteeing optimal solutions for utility costs, maintenance
and versatility.

8

Business

VRF technology offers the best solution for large
commercial and industrial buildings: including hotels,
hospitals, leisure and shopping centers.
The dual inverter compressor guarantees high efficiency
levels, operating flexibility and reduced maintenance
requirements.
The three pipe heat recovery models are extremely
efficient and can operate simultaneously in Heating and
Cooling mode.
Toshiba VRF systems have a wide range of indoor units
which enable designers and tenants to make the right
product choice in terms of aesthetic and performances.

9

Environmental Vision 2050 Ecodesign directive

Through value creation inspired by our three over- The objective of the European Eco Design Directive is the
arching themes - “Surprise and Sensation,” “Safety integration of environmental aspects into product design
and Security,” and “Comfort”- coupled with a with the aim of improving the environmental performance
wholehearted commitment to the prevention of of the product throughout its whole life cycle.
global warming, control of chemical substances and Air conditioners have been identified as Energy Related
efficient utilization of resources, we intend to bring Products (ERPs) because have an impact on energy
our business process and products into ever closer consumption during use.
harmony with the needs of planet Earth. We believe Therefore a set of rules for energy efficiency measurements
these efforts will help to build a sustainable society. and specifications have been defined which will be
As solutions for various environmental issues, integrated in the new energy efficiency label.
including climate change, are called for, Toshiba Toshiba applies the calculation methods of the ecodesign
Group has developed Environmental Vision 2050 to directive and all its products will be in line with Lot10 and
ensure that these environmental issues are solved Lot11 requirements.
and that all people can lead affluent lifestyles in
harmony with the Earth

Energy labeling for air conditioners R-32

Under the new labeling the energy efficiency of air conditioning systems will be calculated
based on seasonal performance. For calculating heating seasonal performance, the EU is
divided into three climate zones, this ensures the energy efficiency calculation applies the
actual regional ambient temperatures.

• Warmer – annual temperature of Athens
• Average – annual temperature of Strasbourg
• Colder – annual temperature of Helsinki

Energy Efficiency Class SEER SCOP

A+++ SEER ≥ 8,50 SCOP ≥ 5,10
A++ 6,10 ≤ SEER < 8,50 4,60 ≤ SCOP < 5,10
A+ 5,60 ≤ SEER < 6,10 4,00 ≤ SCOP < 4,60
5,10 ≤ SEER < 5,60 3,40 ≤ SCOP < 4,00
A 4,60 ≤ SEER < 5,10 3,10 ≤ SCOP < 3,40
B 4,10 ≤ SEER < 4,60 2,80 ≤ SCOP < 3,10
C 3,60 ≤ SEER < 4,10 2,50 ≤ SCOP < 2,80
D

WARMER (ATHENS) AVERAGE (STRASBOURG) COLDER (HELSINKI)

Temperatures Conditions Temperatures Conditions Temperatures Conditions

Partial Outdoors Indoors Partial Outdoors Indoors Partial Outdoors Indoors
Load DB WB DB Load DB WB DB Load DB WB DB

- -- 20OC 88% -7OC - 8OC 20OC 61% -7OC - 8OC 20OC

100% 2OC 1OC 20OC 54% 2OC 1OC 20OC 37% 2OC 1OC 20OC

64% 7OC 6OC 20OC 35% 7OC 6OC 20OC 24% 7OC 6OC 20OC

29% 12OC 11OC 20OC 15% 12OC 11OC 20OC 11% 12OC 11OC 20OC

SEER

Climate zones for calculating Cooling (SEER), only ONE climate zone Temperatures Conditions
for calculating Cooling efficiencies.The climate data for Strasbourg is
the single reference point for the whole of Europe. Partial Outdoors Indoors
Load DB DB WB
10
21% 20OC 27OC 19OC

47% 25OC 27OC 19OC

74% 30OC 27OC 19OC

100% 35OC 27OC 19OC

HIGH TECHNOLOGY
NOW AVAILABLE WITH R32
& R410A REFRIGERANTS

In line with the concept of all Toshiba products, wall unit boasts low energy HFC consumption
consumption. related to tons of
It is A+ energy class in both heating and cooling modes, ensuring CO equivalent
exceptional energy savings and unparalleled comfort levels, in either its
R410A or R32 refrigerant versions. 2018

European F-GAS regulation: -37%
R32 is the right alternative to R410A
2024
The European F-gas regulation (517/2014) has been in force since January
1 2015 and will progressively phase down the use of hydrofluorocarbons -69%
(HFCs) in the heating and cooling systems of the future.
2030
However the use of R32 is gaining momentum, as the drive for high
energy efficiency and low environmental impact refrigerants increases. -79%
This zero-ODP and lower-GWP (only 675) alternative provides substantial
environmental benefit whilst also providing additional advantages such
as substantially lower system charge sizes and higher efficiency versus
R410A.

Toshiba already offers a new heating and cooling system operating
with R32, which will be the alternative to R410A in the years ahead:

• The new R32 refrigerant ensures an ideal balance between
energy efficiency and respect for the environment.

• The quantities of HFCs that areplaced on the market will
be gradually reduced in a step by step approach, until they
finally reach a minimum level by 2030.

11



Residential

Well - being and beyond

Air conditioning plays a fundamental role in your well – being at home
as well as at work. In fact, it is not only important to grant the desired
temperature, it is also the right tool to get the best indoor air quality.

Selecting the most suitable system is the key to maximize performance
and optimize comfort.

Air treatment, low sound levels, guaranteed energy savings and easy
installation of the indoor units make the Toshiba residential range the
top choice for any home.

They have all the features a user can require: elegance, silence, energy
efficiency and pure air delivery.

The ultimate expression of the inverter technology

Toshiba DC hybrid inverter technology controls the capacity supplied
by the air conditioner. By modifying the supply current frequency or
intensity, it ensures smooth linear variation of the rotation speed and
capacity of the compressor – the heart of the air conditioner.

This allows the cooling and heating capacities to be matched to the
actual operating conditions required.

When the room temperature is different from the set point, the air
conditioner operates at maximum capacity, ensuring that a comfortable
temperature will be reached quickly. Once the desired temperature
is reached the inverter precisely adjusts the capacity to maintain a
temperature close to the set point.

Energy saving
Digital technology provides superior control and cost efficiency
with the DC Inverter compressor when compared to AC Fixed
Speed compressors. Super-accurate rotation of an environmentally
sustainable compressor results in power savings of up to 50%* and
quieter operation.

Comparison of energy consumption

Fixed Speed

Inverter 50% Energy Saving

Indoor temperature : Staring from 35ºC until it reaches
a set-point temperature 25ºC.
Testing Condition Ambient temperature : Vary between 28 and 30ºC

by every 2 hours period.
Testing period : More than 8 hours.

*13k Btu Inverter vs. 13k Btu Fixed Speed product

14

Benefits of the Toshiba DC Hybrid Inverter system

Comfort
Toshiba’s DC Hybrid Inverter uses
a Twin Rotary compressor*, which
ensures a steadier rotation therefore
reducing the unwanted vibration
sound.

High power
PAM drives high power to ensure
the fastest achievement of the set
temperature.

No ozone Depletion
At Toshiba, our concerns for the
environment have led us to use the
R410A refrigerant, which is confirmed
to be non-ozone depleting, non-
flammable and non-toxic.

*In specific residential & light commercial models

Advantaged of a DC Twin-Rotary Compressor
• Increased, wide range efficiency is realized
This compressor enables the adoption of a high-pressure refrigerant. High efficiency is evident in low speed operation ranges.
It can reduce energy consumption when operated in long stable conditions.

• High Efficiency
Rotation with two rollers at the same time makes accurate compressor rotation possible with less energy loss.
As a result, it offers a great reduction in energy consumption yet with very powerful operation.

•High reliability & Low Noise
The enhanced DC Twin-rotary compressor delivers stable performance with minimum friction.
Ideal for noise-sensitive applications. The sound of the outdoor unit is almost imperceptible.

Toshiba DC Hybrid Inverter system PWM

PAM
Superior power an percise
control for maximum
comfort and energy savings.

Set Temp.

Unique Hybrid Design DC HYBRID
The Hybrid Inverter features PAM INVERTER
(Pulse Amplitude Modulation) and
PWM (Pulse Width Modulation).

The former provides the highest levels of power while the latter ensures the desired room temperature and energy
efficiency. As a hybrid, the Toshiba Inverter System features the best of both.

15



Residential

Inverter Systems
Single Split

RAS Residential range 8

G2KVP INVERTER HIGH-WALL

New Air Purifier Higher standard in efficiency and comfort.

Impurities are ionized by the High energy efficiency class, both in cooling and heating
plasma ion charger and absorbed (A+++ for sizes 10 & 13).
by heat exchanger
Elegant design.

Low energy consumption in minimum capacity:
When demand is reduced, the unit reduces also its capacity and achieves
lower power consumption.

Wide operating range.

Improved airflow features

Super Ionizer with possibility to enhance humidity in air.

User friendly wireless remote control and optimal customization.

Weekly timer with 4 freely programmable settings per day and 7 different
programs per week (standard).

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-10G2KVP-E RAS-10G2AVP-E WIRELESS
RAS-13G2KVP-E RAS-13G2AVP-E
RAS-16G2KVP-E RAS-16G2AVP-E

18

G2AVP+G2KVP kW Performance data RAS-13G2AVP-E RAS-16G2AVP-E
kW RAS-13G2KVP-E RAS-16G2KVP-E
Outdoor unit kW RAS-10G2AVP-E
Indoor unit W/W RAS-10G2KVP-E 3,50 4,50
Cooling capacity 0,63 - 4,1 0,63 - 5,0
Cooling range (min. - max.) kWh/a 2,50 0,17 - 0,82 - 1,20 0,17 - 1,30 - 1,75
Power input (min. - rated - max.) kWh 0,55 - 3,5
EER kW C 0,11 - 0,485 - 0,9 4,27 3,46
SEER kW 8,90 7,30
Energy efficiency class kW 5,15 A+++ A++
Seasonal electricity consumption 9,10 138 216
Annual energy consumption W/W C A+++ 410 650
Heating capacity C 96 4,0 5,5
Heating range (min. - max.) kWh/a 243 0,65 - 6,3 0,65 - 6,8
Power input (min. - rated - max.) 3,2 0,14- 0,80 - 1,77 0,14 - 1,37 - 2,05
SCOP (Warmer zone) 0,45 - 5,8 6,1 6,00
Energy Class (Warmer zone) H 0,09 - 0,58 - 1,65 A+++ A+++
COP H 6,2 5,00 4,01
SCOP (Average) H A+++ 5,10 4,60
Energy efficiency class (Average) 5,52 A+++ A++
Seasonal electricity consumption 5,20 988 1369
H A+++
H 808 RAS-13G2KVP-E RAS-16G2KVP-E
672 -187 696 - 193
G2KVP Physical data Indoor unit 43/25 (21) 44/26 (23)
58 59
Indoor unit m3/h - l/s C RAS-10G2KVP-E 726 - 202 744 - 207
Air Flow (max) dB(A) C 648 - 180 44/25 (21) 45/26 (23)
Sound pressure level (h/l (q)) dB(A) C 42/24 (20) 59 60
Sound power level (h) H 57
Air Flow (max) m3/h - l/s H 678 - 188 293x831x270 293x831x270
Sound pressure level (h/l (q)) dB(A) H 43/24 (20) 14 14
Sound power level (h) dB(A) 58
Dimensions (HxWxD) mm RAS-16G2AVP-E
Weight kg 293x831x270 2544 - 707
14 49
64
G2AVP m3/h - l/s Physical data Outdoor unit RAS-13G2AVP-E -10~46
dB(A) 2160 - 600 2544 - 707
Outdoor unit dB(A) RAS-10G2AVP-E 48 50
Air Flow (max) °C C 1872 - 520 63 65
Sound pressure level (h) C 46 -10~46 -15~24
Sound power level (h) m3/h - l/s C 61 2160 -600 630x800x300
Operating range dB(A) C -10~46 49 42
Air Flow (max) dBA H 1872 - 520 64
Sound pressure level (h) °C H 47 -15~24 DC Twin Rotary
Sound power level (h) mm H 62 630x800x300 1/2 - 1/4
Operating range kg H -15~24 42 2
Dimensions (HxWxD) 25
Weight inch 630x800x300 DC Twin Rotary 10
Compressor type m 42 3/8 - 1/4 15
Flare connections (gas-liquid) m 2
Minimum pipe length m DC Twin Rotary 25 220/240-1-50, 220/230-1-60
Maximum pipe length m 3/8 - 1/4 10
Maximum height difference V-ph-Hz 2 15 19
Chargeless pipe length 25
Power supply 10 220/240-1-50, 220/230-1-60
15
C = cooling mode
H = heating mode 220/240-1-50, 220/230-1-60

h/l (q)= high / low speed (quiet)

RAS Residential range 6,5

N3KVP INVERTER HIGH-WALL

Indoor Air Quality High standards in efficiency and comfort.

• Plasma air purifier Power change button: reduce the power to 75 or 50%. Helps
• Ionizer preventing black-outs when other appliances are used.

New, modern aesthetic.

Self-cleaning with low density ozone will eliminate all bacteria
normally remaining after operation.

DC Hybrid Inverter technology with Twin Rotary compressor.

New ergonomic and practical remote control with easy access to main
buttons and a sliding panel to hide the control used less frequently.

Nordic version with heat on the base plate of outdoor unit and
winter operation mode.

Weekly timer with 4 freely programmable settings per day and 7 different
programs per week (optional).

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-B10N3KVP-E RAS-10N3AVP-E RAS-M14GAV-E WIRELESS
RAS-B13N3KVP-E RAS-13N3AVP-E RAS-M18UAV-E
RAS-B16N3KVP-E RAS-16N3AVP-E RAS-3M26S3AV-E
RAS-4M27S3AV-E
20 RAS-5M34S3AV-E

N3KVP+N3AVP Performance data

Outdoor unit kW C RAS-10N3AVP-E RAS-13N3AVP-E RAS-16N3AVP-E
Indoor unit kW C RAS-B10N3KVP-E RAS-B13N3KVP-E RAS-B16N3KVP-E
kW C
Cooling capacity W/W 2,51 3,52 4,53
Cooling range (min. - max.) H 0,8 - 3,5 0,9 - 4,1 0,9 - 5,0
Power input (min. - rated - max.) kWh/a 0,14 - 0,49 - 0,9 0,16 - 0,84 - 1,37 0,16 - 1,34 - 1,82
EER kWh H
SEER kW H 5,12 4,19 3,38
Energy efficiency class kW 8,5 7,0 6,6
Seasonal electricity consumption kW A+++ A++ A++
Annual energy consumption 82 175 239
Heating capacity W/W 245 420 670
Heating range (min. - max.) 3,21 4,22 5,53
Power input (min. - rated - max.) kWh/a 0,8 - 5,8 0,8 - 5,9 0,8 - 6,7
SCOP (warmer zone) 0,15 - 0,63 - 1,90 0,16- 0,95 - 1,95 0,17 - 1,47 - 2,51
Energy efficiency class (warmer zone) 4,6 4,5 4,3
COP A+++ A++ A++
SCOP (Average) 5,1 4,44 3,76
Energy efficiency class (Average) 4,6 4,5 4,3
Seasonal electricity consumption A++ A+ A+
852 933 1236

N3KVP Physical data Indoor unit RAS-B13N3KVP-E RAS-B16N3KVP-E
660 -183 690 - 192
Indoor unit m3/h - l/s C RAS-B10N3KVP-E 43/27 45/29
Air Flow (max) dB(A) C 630 - 175 58 60
Sound pressure level (h/l) dB(A) C 42/27 732 - 203 756 - 210
Sound power level (h) m3/h - l/s H 57 44/27 45/29
Air Flow (max) dB(A) H 708 - 197 59 60
Sound pressure level (h/l) dB(A) H 43/27
Sound power level (h) mm 58 275x790x225 275x790x225
Dimensions (HxWxD) kg 10 10
Weight 275x790x225
10 RAS-13N3AVP-E RAS-16N3AVP-E
2160 - 600 2520 - 700
N3AVP Physical data Outdoor unit 48 49
63 64
Outdoor unit m3/h - l/s C RAS-10N3AVP-E -10~46 -10~46
Air Flow (max) dB(A) C 1800 - 500 2160 - 600 2160 - 600
Sound pressure level (h) dB(A) C 46 50 50
Sound power level (h) °C C 61 65 65
Operating range m3/h - l/s H -10~46 -15~24 -15~24
Air Flow (max) dB(A) H 1800 - 500 630x800x300 630x800x300
Sound pressure level (h) dB(A) H 47 41 41
Sound power level (h) °C H 62
Operating range mm -15~24 DC Twin Rotary DC Twin Rotary
Dimensions (HxWxD) kg 630x800x300 3/8 - 1/4 1/2 - 1/4
Weight 41 2 2
Compressor type inch 25 25
Flare connections (gas-liquid) m DC Twin Rotary 10 10
Minimum pipe length m 3/8 - 1/4 15 15
Maximum pipe length m 2
Maximum height difference m 25 220/240-1-50, 220-1-60 220/240-1-50, 220-1-60
Chargeless pipe length V-ph-Hz 10
Power supply 15 21

C = cooling mode 220/240-1-50, 220-1-60
H = heating mode

h/l= high / low speed

RAS Residential range INVERTER HIGH-WALL

N3KV2

Toshiba IAQ filtration system The new and improved Suzumi Plus in new design is a
successful combination of optimized energy efficiency and
effective air cleaning methods.

DC Hybrid Inverter technology with rotary compressor.
New smooth and elegant design.
Self-Cleaning function removes the moisture, while low density ozone decontaminates
the indoor unit.
The one – touch function offers the combination of features that is perfect for you by
pressing only one button.
The comfort sleep function maintains the most comfortable temperature while you sleep.
You can reach immediately the desired temperature by using the Hi POWER function.
The ECO function achieves energy-savings of up to 25% compared with standard
settings without sacrificing comfort.
Toshiba IAQ filters for improving the indoor air quality.
Weekly timer with 4 freely programmable settings per day and 7 different
programs per week (optional).
The provide remote control is a wireless type which also can be used as a wired.

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-B10N3KV2-E1 RAS-10N3AV2-E1 RAS-M14GAV-E WIRELESS
RAS-B13N3KV2-E1 RAS-13N3AV2-E1 RAS-M18UAV-E
RAS-B16N3KV2-E1 RAS-16N3AV2-E RAS-3M26S3AV-E
RAS-18N3KV2-E1 RAS-18N3AV2-E RAS-4M27S3AV-E
RAS-B22N3KV3-E1 RAS-22N3AV2-E RAS-5M34S3AV-E

22

N3KV2+N3AV2 Performance data

Outdoor unit kW RAS-10N3AV2-E1 RAS-13N3AV2-E1 RAS-16N3AV2-E RAS-18N3AV2-E RAS-22N3AV2-E
Indoor unit kW RAS-B10N3KV2-E1 RAS-B13N3KV2-E1 RAS-B16N3KV2-E1 RAS-18N3KV2-E1 RAS-B22N3KV2-E1
Cooling capacity kW C
Cooling range (min. - max.) W/W 2,5 3,5 4,5 5,0 6,0
Power input (min. - rated - max.) 1,1 - 3,0 1,1 - 4,05 0,8 - 5,0 1,1 - 6,0 1,2 - 6,7
EER kWh/a C 0,25 - 0,598 - 0,91 0,26 - 1,05 - 1,55 0,15 - 1,395 - 1,72 0,18 -1,42 - 2,00 0,20 - 1,995 - 2,65
SEER kWh C
Energy efficiency class kW 4,18 3,33 3,23 3,52 3,01
Seasonal electricity consumption kW H 6,7 6,5 6,1 7,0 6,5
Annual energy consumption kW H A++ A++ A++ A++ A++
Heating capacity H 137 189 258 250 323
Heating range (min. - max.) W/W 299 525 698 710 998
Power input (min. - rated - max.) 3,2 4,2 5,5 5,8 7,0
SCOP (Warmer zone) kWh/a H 0,9 - 4,8 1,0 - 5,3 0,9 - 6,9 0,8 - 6,3 1,0 - 7,5
Energy Class (Warmer zone) H 0,19 - 0,75 - 1,40 0,19 - 1,08 - 1,64 0,15 -1,52 -1,98 0,14 - 1,56 -1,70 0,18 - 2,05 - 2,21
COP 5,1 5,00 5,3 5,2 5,2
SCOP (Average) A +++ A ++ A+++ A+++ A+++
Energy efficiency class (Average) 4,27 3,89 3,62 3,72 3,41
Seasonal electricity consumption 4,3 4,0 3,9 4,1 4,0
A+ A+ A A+ A+
944 1119 1362 1400 1645

N3KV2 Physical data Indoor unit RAS-B16N3KV2-E1
684 - 190
Indoor unit m3/h - l/s C RAS-B10N3KV2-E1 RAS-B13N3KV2-E1 45/30 RAS-18N3KV2-E1 RAS-B22N3KV2-E1
Air Flow (max) dB(A) C 516 - 143 570 - 158 60 954 - 265 1080 - 300
Sound pressure level (h/l) dB(A) C 38/26 39/26 738 - 205 44/32 47/35
Sound power level (h) m3/h - l/s H 53 54 45/31 59 60
Air Flow (max) dB(A) H 570 - 158 624 - 173 60 990-275 1098-305
Sound pressure level (h/l) dB(A) H 39/28 40/28 44/32 47/35
Sound power level (h) mm 54 55 275 x 790 x 217 59 60
Dimensions (HxWxD) kg 10
Weight 275 x 790 x 217 275 x 790 x 217 320 x 1050 x 229 320 x 1050 x 229
10 10 RAS-16N3AV2-E 13 13
2160 - 600
N3AV2 Physical data Outdoor unit 49
64
Outdoor unit m3/h - l/s C RAS-10N3AV2-E1 RAS-13N3AV2-E1 -10~46 RAS-18N3AV2-E RAS-22N3AV2-E
Air Flow (max) dB(A) C 1800 - 500 2250 - 625 1920 - 533 2178 - 605 2316 - 643
Sound pressure level (h) dB(A) C 46 48 50 49 53
Sound power level (h) °C C 61 63 65 64 65
Operating range m3/h - l/s H -10~46 -10~46 -15~24 -10~46 -10~46
Air Flow (max) dB(A) H 1800 - 500 2250 - 625 1914 -532 2232 - 620
Sound pressure level (h) dB(A) H 47 50 550 x 780 x290 50 52
Sound power level (h) °C H 62 65 38 65 65
Operating range mm -15~24 -15~24 -15~24 -15~24
Dimensions (HxWxD) kg DC Twin Rotary
Weight 550 x 780 x 290 550 x 780 x 290 1/2 - 1/4 550 x 780 x 290 550 x 780 x 290
Compressor type inch 33 34 2 39 41
Flare connections (gas-liquid) m 20
Minimum pipe length m DC Rotary DC Rotary 10 DC Twin Rotary DC Twin Rotary
Maximum pipe length m 3/8 - 1/4 3/8 - 1/4 15 1/2 - 1/4 1/2 - 1/4
Maximum height difference m 2 2
Chargeless pipe length 2 2 220/240-1-50, 20 20
V-ph-Hz 20 20 220/230-1-60 10 10
Power supply 10 10 15 15
15 15
C = cooling mode 220/240-1-50, 220/240-1-50,
H = heating mode 220/240-1-50, 220/240-1-50, 220/230-1-60 220/230-1-60
220/230-1-60 220/230-1-60
h/l= high / low speed

23

RAS Residential range NEW R32

ΒKVG INVERTER HIGH-WALL

13% Bigger Superior Comfort
Dustless Coil
A+++ Energy Class in Heating Mode*
My new design object, direct from the future
Improved energy grade in both heating and cooling modes
New high-end compressor (made in Japan)
Sleek design
Bigger indoor units’ fan, 13% bigger to increase airflow volume
Weekly timer with 4 freely programmable settings per day and 7 different
programs per week (optional)
Hepa & Cold Catalyst filters

*Size 16, warmer zone

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-07BKVG-E RAS-07BAVG-E (optional)
RAS-10BKVG-E RAS-10BAVG-E
RAS-13BKVG-E RAS-13BAVG-E
RAS-16BKVG-E RAS-16BAVG-E

24

BKVG+BAVG Performance data

Outdoor unit kW RAS-07BAVG-E RAS-10BAVG-E RAS-13BAVG-E RAS-16BAVG-E
Indoor unit kW RAS-07BKVG-E RAS-10BKVG-E RAS-13BKVG-E RAS-16BKVG-E
Cooling capacity kW C
Cooling range (min. - max.) W/W 2,0 2,5 3,3 4,6
Power input (min. - rated - max.) (0.67 - 2.60) (0.68 - 3.00) (0.75 - 3.60) 1,20 - 5,3
EER kWh/a C (0.14 - 0.58 - 0.83) (0.18 - 0.77 - 1.00) (0.18 - 1.13 - 1.25) (0,22 - 1,53 - 1,80)
SEER kWh C
Energy efficiency class kW 3.45 3.25 2.92 3.01
Seasonal electricity consumption kW H 5.6 5,7 5,6 6.2
Annual energy consumption kW H A+ A+ A+ A++
Heating capacity H 125 153 206 260
Heating range (min. - max.) W/W 290 385 565 765
Power input (min. - rated - max.) 2,5 3.2 3.6 5.4
SCOP (Warmer zone) kWh/a H (0.55 - 3.30) (0.71 - 3.90) (0.72 - 4.50) 0,93 - 6,40
Energy Class (Warmer zone) H (0.12 - 0.64 - 0.90) (0.15 - 0.85 - 1.11) (0.15 - 0.96 - 1.24) (0,18 - 1,55 - 2,10)
COP 4,46 4,63 4,81 5,4
SCOP (Average) A+ A++ A++ A+++
Energy efficiency class (Average) 3.91 3.76 3.75 3.48
Seasonal electricity consumption 4,0 4,0 4,0 4.2
A+ A+ A+ A+
700 839 980 1334

BKVG Physical data Indoor unit RAS-13BKVG-E RAS-16BKVG-E
600 - 167 750 - 208
Indoor unit m3/h - l/s C RAS-07BKVG-E RAS-10BKVG-E 264 - 73 330 - 92
Air Flow (h) m3/h - l/s C 522 - 145 540 - 150 41/24 43/25
Air Flow (l) dB(A) C 234 - 65 240 - 67 56 58
Sound pressure level (h/l) dB(A) C 38/23 39/24 618 - 172 768 - 213
Sound power level (h) m3/h - l/s H 53 54 294 - 8,2 348 - 97
Air Flow (h) m3/h - l/s H 534 - 148 552 - 153 45/24 43/25
Air Flow (l) dB(A) H 246 - 68 252 - 70 57 58
Sound pressure level (h/l) dB(A) H 38/23 39/24
Sound power level (h) mm 53 54 293 x 798 x 230 293 x 798 x 230
Dimensions (hxwxd) kg 9 10
Weight 293 x 798 x 230 293 x 798 x 230
9 9 RAS-13BAVG-E RAS-16BAVG-E
1980 - 550 2040 - 567
BAVG Physical data Outdoor unit 50 50
65 65
Outdoor unit m3/h - l/s C RAS-07BAVG-E RAS-10BAVG-E -15 ~ 46 -15~46
Air Flow (max) dB(A) C 1740 - 483 1860 - 517 1980 - 550 2160 - 600
Sound pressure level (h) dB(A) C 48 49 51 52
Sound power level (h) °C C 63 64 66 67
Operating range m3/h - l/s H -15 ~ 46 -15 ~ 46 -15~24 -15~24
Air Flow (max) dB(A) H 1800 - 500 1860 - 517
Sound pressure level (h) dB(A) H 50 51 530 x 660 x 240 550 x 780 x 290
Sound power level (h) °C H 65 66 22 34
Operating range mm -15 ~ 24 -15 ~ 24
Dimensions (HxWxD) kg DC Rotary DC Rotary
Weight 530 x 660 x 240 530 x 660 x 240 3/8" - 1/4" 1/2" - 1/4"
Compressor type inch 21 21
Flare connections (gas-liquid) m 2 2
Minimum pipe length m DC Rotary DC Rotary 15 20
Maximum pipe length m 3/8" - 1/4" 3/8" - 1/4" 12 12
Maximum height difference m 15 15
Chargeless pipe length 2 2 220-240/1/50 220-240/1/50
V-ph-Hz 15 15
Power supply 12 12
15 15

220-240/1/50 220-240/1/50

C = cooling mode
H = heating mode
h/l= high / low speed

25

RAS Residential range NEWR410A

ΒKV INVERTER HIGH-WALL

White LEDs looks elegant New era of Toshiba Hi wall units.
in night-time
Attractive design by big-round shape, providing slimmer look, with smooth-glossy
surface and luxury bright-white LED indicators

Energy efficiency, comfort, and reliability
Indoor sound pressure has been reduced, giving highly comfortable environment
Smaller pipe, more condensed, less refrigerant used and energy efficiency increased
Healthy & Fresh air / none bad-smell (mold & bad odor)
Hepa & Cold catalyst filters
New high-end compressor (made in Japan)
Weekly timer with 4 freely programmable settings per day and
7 different programs per week (optional)

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-07BKV-E RAS-07BAV-E (optional)
RAS-10BKV-E RAS-10BAV-E
RAS-13BKV-E RAS-13BAV-E
RAS-16BKV-E RAS-16BAV-E

26

BKV+BAV Performance data

Outdoor unit kW RAS-07BAV-E RAS-10BAV-E RAS-13BAV-E RAS-16BAV-E
Indoor unit kW RAS-07BKV-E RAS-10BKV-E RAS-13BKV-E RAS-16BKV-E
Cooling capacity kW C
Cooling range (min. - max.) W/W 2,0 2,5 3,1 4,4
Power input (min. - rated - max.) 0.64 - 2.50 0.67 - 3.10 0.75 - 3.50 1,1 -4,8
EER kWh/a C 0.14 - 0.60 - 0.86 0.165 - 0.85 - 1.19 0.18 - 1.15 - 1.33 0,21 - 1,56 - 1,72
SEER kWh C 2,82
Energy efficiency class kW 3.33 2.94 2.70
Seasonal electricity consumption kW H 5.7 5,6 5,7 5,9
Annual energy consumption kW H A+ A+ A+ A+
Heating capacity H 123 156 190 261
Heating range (min. - max.) W/W 300 425 575 780
Power input (min. - rated - max.) 2,5 3.2 3.6 5.2
SCOP (Warmer zone) kWh/a H 0.55 - 3.20 0.70 - 3.90 0.70 - 4.50 0,80 - 6,10
Energy Class (Warmer zone) H 0,13 - 0,62 - 0,82 0.15 - 0.84 - 1.06 0.15 - 0.96 - 1.24 0,16 - 1,52 - 1,90
COP 4,32 4,6 4,69 5,32
SCOP (Average) A+ A++ A++ A+++
Energy efficiency class (Average) 4.03 3.81 3.75 3,42
Seasonal electricity consumption 4,0 4,0 4,0 4,2
A+ A+ A+ A+
630 840 980 1333

BKV Physical data Indoor unit RAS-13BKV-E RAS-16BKV-E
600 - 167 720 - 200
Indoor unit m3/h - l/s C RAS-07BKV-E RAS-10BKV-E 264 - 73 318 - 88
Air Flow (h) m3/h - l/s C 522 - 145 540 - 150 41/24 44/25
Air Flow (l) dB(A) C 234 - 65 240 - 67 56 59
Sound pressure level (h/l) dB(A) C 38/22 40/23 618 - 172 756 - 210
Sound power level (h) m3/h - l/s H 54 55 294 - 82 348 - 97
Air Flow (h) m3/h - l/s H 534 - 148 552 - 153 45/24 43/26
Air Flow (l) dB(A) C 246 - 68 252 - 70 57 58
Sound pressure level (h/l) dB(A) C 40/22 41/23
Sound power level (h) mm 55 56 293 x 798 x 230 293 x 798 x 230
Dimensions (hxwxd) kg 9 9
Weight 293 x 798 x 230 293 x 798 x 230
9 9 RAS-13BAV-E RAS-16BAV-E
1980 - 550 2040 - 567
BAV Physical data Outdoor unit 48 49
64 64
Outdoor unit m3/h - l/s C RAS-07BAV-E RAS-10BAV-E -15 ~ 46 -15~46
Air Flow (max) dB(A) C 1740 - 483 1860 - 517 1980 - 550 2040 - 567
Sound pressure level (h) dB(A) C 48 48 50 50
Sound power level (h) °C C 62 63 65 65
Operating range m3/h - l/s H -15 ~ 46 -15 ~ 46 -15~24 -15~24
Air Flow (max) dB(A) H 1800 - 500 1860 - 517
Sound pressure level (h) dB(A) H 50 50 530 x 660 x 240 550 x 780 x 290
Sound power level (h) °C H 64 65 22 34
Operating range mm -15 ~ 24 -15 ~ 24
Dimensions (HxWxD) kg DC Rotary DC Rotary
Weight 530 x 660 x 240 530 x 660 x 240 3/8" - 1/4" 1/2" - 1/4"
Compressor type inch 21 21
Flare connections (gas-liquid) m 2 2
Minimum pipe length m DC Rotary DC Rotary 15 20
Maximum pipe length m 3/8" - 1/4" 3/8" - 1/4" 12 12
Maximum height difference m 15 15
Chargeless pipe length 2 2 220-240/1/50 220-240/1/50
Power supply V-ph-Hz 15 15
12 12
C = cooling mode 15 15
H = heating mode
220-240/1/50 220-240/1/50
h/l= high / low speed

27

RAS Residential range INVERTER HIGH-WALL

7SKV

Self cleaning function If your need is ideal temperature all year round,
delivered with high energy saving and extremely low
AvAnt is endowed with the self-cleaning noise, Toshiba AvAnt Inverter is the solution.
function, that prevents moisture and mould to
be formed in the indoor unit. Improved energy efficiency in cooling and heating.
When the air conditioner is turned off, the Compact design fit easily into every room.
internal fan runs and dries the moisture coil, Wider usable operating range.
before turning off automatically. User friendly remote control.
Detachable front panel for regular maintenance routines.
Weekly timer with 4 freely programmable settings per day and 7 different
programs per week (optional).

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-107SKV-E7 RAS-107SAV-E6 WIRELESS
RAS-137SKV-E7 RAS-137SAV-E6
RAS-167SKV-E7 RAS-167SAV-E5

28

7SKV+7SAV kW Performance data RAS-137SAV-E6 RAS-167SAV-E5
kW RAS-137SKV-E7 RAS-167SKV-E7
Outdoor unit kW RAS-107SAV-E6
Indoor unit W/W RAS-107SKV-E7 3,15 4,4
Cooling capacity 1,2-3,6 1,1-5,0
Cooling range (min. - max.) kWh/a 2,5 0,28-1,10-1,50 0,26-1,56-1,90
Power input (min. -rated - max.) kWh 1,2-3,0 2,86 2,82
EER kW C 0,29-0,77-1,05
SEER kW 3,25 5,1 5,8
Energy efficiency class kW A A+
Seasonal electricity consumption W/W 5,1 213 266
Annual energy consumption CA 550 780
Heating capacity kWh/a C 171 3,6 5,2
Heating range (min. - max.) 0,95-4,0 1,0-6,2
Power input (min. - rated - max.) 385 0,21 - 0,95 - 1,18 0,19 - 1,52 - 1,81
COP 3,2 3,79 3,42
SCOP (Average) 0,9-3,5 3,8 3,8
Energy efficiency class (Average) H 0,21 - 0,84- 0,97 A A
Seasonal electricity consumption 3,81 921 1399
3,8
HA RAS-167SKV-E7
H 736 690 - 192
45/30
7SKV m3/h - l/s C Physical data Indoor unit RAS-137SKV-E7 60
dB(A) C 570 - 158 744 - 207
Indoor unit dB(A) C RAS-107SKV-E7 41/28 45/31
Air Flow (max) m3/h - l/s H 528 - 147 56 60
Sound pressure level (h/l) dB(A) H 40/27 588 - 163
Sound power level (h) dB(A) H 55 42/29 275x790x205
Air Flow (max) mm 570 - 158 57 9
Sound pressure level (h/l) kg 41/28
Sound power level (h) 56 275x790x205 RAS-167SAV-E5
Dimensions (HxWxD) 9 2250 - 625
Weight 275x790x205 49
9 64
-10~46
7SAV Physical data Outdoor unit 2250 - 625
50
Outdoor unit m3/h - l/s C RAS-107SAV-E6 RAS-137SAV-E6 65
Air Flow (max) dB(A) C 1740 - 483 1860 - 517 -15~24
Sound pressure level (h) dB(A) C 48 48 550x780x290
Sound power level (h) °C C 63 63 40
Operating range m3/h - l/s H -10~46 -10~46 DC Rotary
Air Flow (max) dB(A) H 1740 - 483 1860 - 517 1/2 - 1/4
Sound pressure level (h) dB(A) H 50 50 2
Sound power level (h) °C H 65 65 20
Operating range mm -15~24 -15~24 10
Dimensions (HXWXD) kg 530x660x240 530x660x240 15
Weight 28 28 220-240/1/50
Compressor type inch DC Rotary DC Rotary 220-230/1/60
Flare connections (gas-liquid) m 3/8 - 1/4 3/8 - 1/4
Minimum pipe length m 2 2 29
Maximum pipe length m 15 15
Maximum height difference m 8 8
Chargeless pipe length 15 15
V-ph-Hz
Power supply 220-240/1/50 220-240/1/50
220-230/1/60 220-230/1/60

C = cooling mode, H = heating mode
h/l= hIgh/low speed

RAS Residential range UFV

UFV INVERTER CONSOLE

Bi-flow air delivery system Innovative and compact unit to be installed on the floor
and in low wall applications, fit perfectly under
the window sills or in a low ceiling attic.

This feature enables users to select the Compact and modern design in all three dimensions (60x70x22 cm).
favorable air flow outlet between the two Toshiba IAQ filtration system.
available positioned at the top and bottom Child lock function on the unit display panel.
front of the unit. Brightness level control of the display unit to reduce the led light glow.
The warm air distributed from the Automatic restart function in case of unexpected electricity supply
bottom front is a Toshiba unique feature. line power cuts.

INDOOR UNITS OUTDOOR UNITS REMOTE CONTROLS

RAS-B10UFV-E1 RAS-10N3AV2-E1 RAS-2M14S3AV-E WIRELESS
RAS-B13UFV-E1 RAS-13N3AV2-E1 RAS-2M18S3AV-E
RAS-B18UFV-E1 RAS-18N3AV2-E1 RAS-3M26S3AV-E
RAS-4M27S3AV-E
30 RAS-5M34S3AV-E

B_UFV+N3AV2 kW Performance data RAS-13N3AV2-E1 RAS-18N3AV2-E
kW RAS-B13UFV-E1 RAS-B18UFV-E1
Outdoor unit kW RAS-10N3AV2-E1
Indoor unit W/W RAS-B10UFV-E1 3,5 5,0
Cooling capacity 1,1 - 4,1 1,1 - 5,7
Cooling range (min. - max.) kWh/a 2,5 0,23 - 1,05 - 1,50 0,20 - 1,66 - 1,95
Power input (min. -rated - max.) kWh 1,1 - 3,1
EER kW C 0,23 - 0,595 - 0,91 3,33 3,01
SEER kW 6,3 5,7
Energy efficiency class kW 4,20 A++ A+
Seasonal electricity consumption W/W 6,6 194 307
Annual energy consumption C A++ 525 830
Heating capacity kWh/a C 133 4,2 5,8
Heating range (min. - max.) 298 1,0 - 5,0 1,1 - 6,3
Power input (min. -rated - max.) 3,2 0,18 - 1,25 - 1,80 0,20 - 1,805 - 2,20
COP 1,0 - 4,8 3,36 3,21
SCOP (Average) H 0,18 - 0,75 - 1,55 4,0 3,8
Energy efficiency class (Average) 4,27 A+ A
Seasonal electricity consumption 4,1 1085 1474
H A+
H 1024 RAS-B13UFV-E1 RAS-B18UFV-E1
510 - 142 600 - 167
B_UFV m3/h - l/s C Physical data Indoor unit 270 - 75 366 - 102
m3/h - l/s C 40/27 (24) 46/34 (31)
Indoor unit C RAS-B10UFV-E1 54 60
Air Flow (h) dB(A) C 468 - 130 552 - 153 642 - 178
Air Flow (l) H 258 - 72 288 - 80 366 - 102
Sound pressure level (h/l)(q) dB(A) H 39/26 (23) 40/27 (24) 46/34 (31)
Sound power level (h) m3/h - l/s H 54 55 60
Air Flow (h) m3/h - l/s H 510 - 142
Air Flow (l) 270 - 75 600 x 700 x 220 600 x 700 x 220
Sound pressure level (h/l)(q) dB(A) 39/26 (23) 16 16
Sound power level (h) 54
Dimensions (HxWxD) dB(A) RAS-18N3AV2-E
Weight 600 x 700 x 220 2178 - 605
mm 16 49
64
kg -10~46
1914 - 532
N3AV2 m3/h - l/s C Physical data Outdoor unit RAS-13N3AV2-E1 50
dB(A) C 2250 - 625 64
Outdoor unit dB(A) C RAS-10N3AV2-E1 48 -15~24
Air Flow (max) °C C 1800 - 500 63
Sound pressure level (h) m3/h - l/s H 46 -10~46 550 x 780 x 290
Sound power level (h) dB(A) H 61 2250 - 625 39
Operating range dB(A) H -10~46 50
Air Flow (max) °C H 1800 - 500 65 DC Twin Rotary
Sound pressure level (h) mm 47 -15~24 1/2 - 1/4
Sound power level (h) kg 62 2
Operating range -15~24 550 x 780 x 290 20
Dimensions (HxWxD) inch 34 10
Weight m 550 x 780 x 290 15
Compressor type m 33 DC Rotary
Flare connections (gas-liquid) m 3/8 - 1/4 220/240-1-50, 220/230-1-60
Minimum pipe length m DC Rotary
Maximum pipe length V-ph-Hz 3/8 - 1/4 2 31
Maximum height difference 20
Chargeless pipe length 2 10
Power supply 20 15
10 220/240-1-50, 220/230-1-60
15
220/240-1-50, 220/230-1-60

C = cooling mode, H = heating mode
h/l= hIgh/low speed
q = quiet operation



Residential

Inverter Systems
Multi Split

34

Inverter Systems - Multi Split Hi-wall Console Ducted Cassette

Hi-wall

HEAT PUMP INDOOR UNIT N3KVP N3KV2 UFV G3DV SMUV
RAS-2M14S3AV-E
RAS-2M18S3AV-E HP 7 - RAS-M07N3KV2-E1 - RAS-M07G3DV-E -
RAS-3M18S3AV-E RAS-B10N3KVP-E
RAS-3M26S3AV-E HP 10 RAS-B13N3KVP-E RAS-B10N3KV2-E1 RAS-B10UFV-E1 RAS-M10G3DV-E RAS-M10SMUV-E

RAS-4M27S3AV-E HP 13 RAS-B10N3KVP-E RAS-B13N3KV2-E1 RAS-B13UFV-E1 RAS-M13G3DV-E RAS-M13SMUV-E
HP 7 RAS-B13N3KVP-E RAS-M07N3KV2-E1 - RAS-M07G3DV-E -
RAS-5M34S3AV-E
HP 10 RAS-B13N3KVP-E RAS-B10N3KV2-E1 RAS-B10UFV-E1 RAS-M10G3DV-E RAS-M10SMUV-E

HP 13 RAS-B10N3KVP-E RAS-B13N3KV2-E1 RAS-B13UFV-E1 RAS-M13G3DV-E RAS-M13SMUV-E
RAS-B13N3KVP-E
HP 16 RAS-B16N3KVP-E RAS-B16N3KV2-E1 - RAS-M16G3DV-E RAS-M16SMUV-E
HP 7 RAS-M07N3KV2-E1 - RAS-M07G3DV-E -
RAS-B10N3KVP-E
HP 10 RAS-B13N3KVP-E RAS-B10N3KV2-E1 RAS-B10UFV-E1 RAS-M10G3DV-E RAS-M10SMUV-E
RAS-B16N3KVP-E
HP 13 RAS-B13N3KV2-E1 RAS-B13UFV-E1 RAS-M13G3DV-E RAS-M13SMUV-E
- RAS-B16N3KV2-E1 - RAS-M16G3DV-E RAS-M16SMUV-E
HP 16 -
- RAS-M07N3KV2-E1 - RAS-M07G3DV-E -
HP 7 - RAS-B10N3KV2-E1 RAS-B10UFV-E1 RAS-M10G3DV-E RAS-M10SMUV-E
HP 10 RAS-B10N3KVP-E
RAS-B13N3KVP-E RAS-B13N3KV2-E1 RAS-B13UFV-E1 RAS-M13G3DV-E RAS-M13SMUV-E
HP 13 RAS-B16N3KVP-E RAS-B16N3KV2-E1 - RAS-M16G3DV-E RAS-M16SMUV-E
HP 16 -
HP 18 - - RAS-B18UFV-E1 - -
HP 22 - RAS-B22N3KV2-E1 - - -
HP 24 - RAS-M24N3KV2-E1 - - -
HP 7 RAS-B10N3KVP-E RAS-M07N3KV2-E1 - RAS-M07G3DV-E -
HP 10 RAS-B13N3KVP-E RAS-B10N3KV2-E1 RAS-M10G3DV-E RAS-M10SMUV-E
HP 13 RAS-B16N3KVP-E RAS-B13N3KV2-E1 RAS-B10UFV-E1 RAS-M13G3DV-E RAS-M13SMUV-E
HP 16 - RAS-B16N3KV2-E1 RAS-B13UFV-E1 RAS-M16G3DV-E RAS-M16SMUV-E
HP 18 - - -
HP 22 - - - - -
HP 24 RAS-B22N3KV2-E1 RAS-B18UFV-E1 - -
HP 7 RAS-M24N3KV2-E1 RAS-M07G3DV-E -
HP 10 RAS-M07N3KV2-E1 - RAS-M10G3DV-E RAS-M10SMUV-E
HP 13 RAS-B10N3KV2-E1 - RAS-M13G3DV-E RAS-M13SMUV-E
HP 16 RAS-B13N3KV2-E1 - RAS-M16G3DV-E RAS-M16SMUV-E
HP 18 RAS-B16N3KV2-E1 RAS-B10UFV-E1 - -
HP 22 RAS-B13UFV-E - -
HP 24 - - - -
RAS-B22N3KV2-E1 RAS-B18UFV-E1
RAS-M24N3KV2-E1 - 35
-

RAS Residential range MULTI-SPLIT

S3AV NEW OUTDOOR UNIT

This new outdoor unit for multi series can serve up to
five indoor units for exceptional flexibility.

Superior reliability and performance as it is equipped with DC Twin Rotary compressor.
Improved energy efficiency class: A++ in cooling and A+ in heating.
Operating range expansion: -10 ~ 46oC in cooling and -15 ~ 24oC in heating.
Compatible with hiwalls, ducted, cassette and console indoor units.
Low noise levels.

OUTDOOR UNITS

RAS-3M26S3AV-E
RAS-4M27S3AV-E
RAS-5M34S3AV-E

36

S3AV Performance data

Outdoor unit 2-room 2-room 3-room 3-room 4-room 5-room
RAS-2M14S3AV-E RAS-2M18S3AV-E RAS-3M18S3AV-E RAS-3M26S3AV-E RAS-4M27S3AV-E RAS-5M34S3AV-E
Cooling capacity kW C
Cooling capacity (min. - max.) kW C 4 5,2 5,2 7,5 8,0 10,0
Power input kW H 1,6-4,9 1,7-6,2 2,4-6,5 4,1-9,0 4,2 - 9,3 3,7 - 11,0
EER W/W H 0,83 1,34 2,00
SEER 4,82 3,88 1,17 3,75 2.29 2,98
Energy efficiency class kW 6,73 6,90 4,44 6,19 3.50 3,36
Heating capacity kW A++ A++ 6,80 A++ 6.11 6,31
Heating capacity (min. - max.) kW A++ A++ A++
Power input W/W 4,4 5,6 6,8 9,0 9.0 12,0
COP 1,3-5,2 1,3-7,5 1,9-8,0 2,0-11,2 2,9 - 11,7 2,7 - 14,0
SCOP (Average) 0,85 1,19 1,58 1,93 2,83
Energy efficiency class (Average) 5,18 4,71 4,30 2,2 4,67 4,24
4,41 4,60 4,60 4,09 4,26 4,08
A++ A++ 4,44 A+ A+
A+ A+

S3AV Physical data outdoor

Outdoor unit - - - 3-room Multisplit 4-room Multisplit 5-room Multisplit
RAS-3M26S3AV-E RAS-4M27S3AV-E RAS-5M34S3AV-E
Air Flow m3/h-l/s C 1863-517 2107-585 2177-605
Sound pressure level dB(A) C 45 47 47 2507-696 2507-696 3245-901
Sound power level dB(A) C 58 60 60 48 48 52
Operating range °C C 63 63 66
Air Flow m3/h-l/s H -10/46 -10/46 -10/46
Sound pressure level dB(A) H 1863-517 2038-566 2107-585 -10/46 -10/46 -10/46
Sound power level dB(A) H 2507-696 2507-696 3562-989
Operating range °C H 46 50 50
Dimensions (HxWxD) mm 59 63 63 49 49 55
Weight kg -20/24 -20/24 -20/24 64 64 68
Compressor type 630 x 800 x 300 630 x 800 x 300 630 x 800 x 300 -15/24 -15/24 -15/24
Flare connections - gas inch 44 44 46 890 x 900 x 320 890 x 900 x 320 890 x 900 x 320
Flare connections - liquid inch DC Twin Rotary DC Twin Rotary DC Twin Rotary 72 72 78
Maximum pipe length (per unit/total) m 3/8" x 2 3/8" x 2 3/8" x 2 + 1/2"×1 DC Twin Rotary DC Twin Rotary DC Twin Rotary
Maximum height difference m 1/4" x 2 1/4" x 2 1/4" x 3 3/8" x 1 + 1/2"×2 3/8" x 2 + 1/2"×2 3/8" x 3 + 1/2"×2
Chargeless pipe length m 20/30 20/30 25/50 1/4" x 3 1/4" x 4 1/4" x 5
Power supply V-ph-Hz 10 10 10 25/ 70 25 / 70 25 / 80
30 30 50 15 15 15
220/240-1-50 220/240-1-50 220/240-1-50 40 40 40
220/240-1-50 220/240-1-50 220/240-1-50

C= cooling mode
H = heating mode

37

RAS Residential range MULTI SPLIT 4-WAY CASSETTE

SMUV INDOOR UNIT

Standard size Its compact and stylish panel design makes it discreet
and unobtrusive.
Stylish design and compact dimensions
to suit all standard 600 x 600 mm grid Complete range from 10 to 16 kW.
ceilings. Easy maintenance: easy access to electrical box by simply removing the suction grill.
Easy installation by panel adjust pocket.
All units equipped with IR remotes as standard.
Corner pocket opening.

SMUV Physical data Indoor unit

Indoor unit HP C RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E
Air Flow (max) m3/h - l/s C 588 - 163 618 - 172 660 - 183
Sound pressure level (h/l) dB(A) C 37/30 38/30 40/31
Sound power level (h) dB(A) H 52 53 55
Air Flow (max) m3/h H 558 - 432 618 - 432 660 - 450
Sound pressure level (h/l) dB(A) H 37/30 38/30 40/31
Sound power level (h) dB(A) 52 53 55
Dimensions (HxWxD) mm
Weight kg 268x575x575 268x575x575 268x575x575
Flare connections (gas - liquid) inch 15 15 15

3/8 - 1/4 3/8 - 1/4 1/2 - 1/4

C = cooling mode H = heating mode h/l= high / low speed

38

RAS Residential range MULTI SPLIT DUCTED

G3DV INDOOR UNIT

Slim design The compact and quiet units are suitable for a wide
range of residential and light commercial applications,
210mm with one outdoor unit serving up to four indoor units.

Very slim design and only 210mm mm Easy-to-use infrared remote control or wired remote control as an option.
high, for easier and versatile installations. Low noise level: the unit operates very quietly.
Flexible air inlet: rear or below the unit.
Drain pump kit available as standard.
Up to 63,7 Pa static pressure.

G3DV Physical data Indoor unit

Indoor unit HP C RAS-M10G3DV-E RAS-M13G3DV-E RAS-M16G3DV-E
Air Flow (h/l) m3/h C 570/380 610/385 780/420
Sound pressure level (h/l) dB(A) C 35/27 37/27 35/24
Sound power level (h/l) dB(A) H 50/42 52/42 50/39
Air Flow m3/h H 570/380 610/385 780/450
Sound pressure level (h/l) dB(A) H 35/27 37/27 35/24
Sound power level (h/l) dB(A) 50/42 52/42 50/40
Dimensions (HxWxD) mm
Weight kg 210×700×450 210×700×400 210×900×450
Flare connections (gas - liquid) inch 16 16 19
External static pressure (S/M1/M2/U) Pa
3/8- 1/4 3/8- 1/4 1/2 - 1/4
10/20/35/45 10/20/35/45 10/20/35/45

C = cooling mode H = heating mode h /l = high / low speed
S / M1 /M2 / U = Standard / Middle1 / Middle 2 / Upper
39

RAS Residential range 6,5 MULTI-SPLIT HI-WALL

N3KVP INDOOR UNIT

Indoor Air Quality High standards in efficiency and comfort.

• Plasma air purifier Power change button: reduce the power to 75 or 50%. Helps
• Ionizer preventing black-outs when other appliances are used.

New, modern aesthetic.

Self-cleaning with low density ozone will eliminate all bacteria
normally remaining after operation.

New ergonomic and practical remote control with easy access to main
buttons and a sliding panel to hide the control used less frequently.

N3KVP HP C Physical data Indoor unit RAS-B13N3KVP-E RAS-B16N3KVP-E
m3/h - l/s C 660 - 183 690 - 192
Indoor unit dB(A) C RAS-B10N3KVP-E 43/27 45/29
Air Flow (max) dB(A) H 630 - 175 58 60
Sound pressure level (h/l) m3/h - l/s H 42/27 732 - 203 756 - 210
Sound power level (h) dB(A) H 58 44/27 45/29
Air Flow (max) dB(A) 708 - 197 59 60
Sound pressure level (h/l) mm 43/27
Sound power level (h) kg 58 275x790x225 275x790x225
Dimensions (HxWxD) inch 10 10
Weight 275x790x225
Flare connections (gas - liquid) 10 3/8 - 1/4 1/2 - 1/4

40 3/8 - 1/4 C = cooling mode

H = heating mode h/l= high / low speed

RAS Residential range MULTI-SPLIT HI-WALL

N3KV2 INDOOR UNIT

Toshiba IAQ The new and improved Suzumi Plus in new design
filtration system is a successful combination of optimized energy
efficiency and effective air cleaning methods.

New smooth and elegant design.
Self-Cleaning function removes the moisture, while low density ozone
decontaminates the indoor unit.
The one – touch function offers the combination of features that is perfect for
you by pressing only one button.
The comfort sleep function maintains the most comfortable temperature while
you sleep.
You can reach immediately the desired temperature by using the Hi POWER
function.
The ECO function achieves energy-savings of up to 25% compared with
standard settings without sacrificing comfort.
Toshiba IAQ filters for improving the indoor air quality.

N3KV2 Physical data Indoor unit

Indoor unit RAS- C M07N3KV2-E1 B10N3KV2-E1 B13N3KV2-E1 B16N3KV2-E1 B22N3KV2-E1 M24N3KV2-E1
Air Flow (max) m3/h - l/s C 516 - 143 516 - 143 570 - 158 684 - 190 1080 - 300 1134 - 315
Sound pressure level (h/l) dB(A) C 38/26 38/26 39/26 45/30 47/35 49/37
Sound power level (h/l) dB(A) H 53 53 54 60 60/48 62/50
Air Flow (max) m3/h - l/s H 570 - 158 570 - 158 624 - 173 738 - 205 1098 - 305 1152 - 320
Sound pressure level (h/l) dB(A) H 39/28 39/28 40/28 45/31 47/35 49/37
Sound power level (h/l) dB(A) 53 54 55 60 60/48 62/50
Dimensions (HxWxD) mm
Weight kg 275 x 790 x 217 275 x 790 x 217 275 x 790 x 217 275 x 790 x 217 320 x 1050 x 229 320 x 1050 x 229
Flare connections (gas - liquid) inch 10 10 10 10 13 13

3/8 - 1/4 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4

41

RAS Residential range MULTI-SPLIT CONSOLE

UFV INDOOR UNIT

Floor heating function Innovative and compact unit to be installed on the
floor and in low wall applications, fit perfectly under
Unique floor heating function, to deliver a the window sills or in a low ceiling attic.
powerful flow at floor level for a uniform
and comfortable room heating. Compact and modern design in all three dimensions (60x70x22 cm).
Toshiba IAQ filtration system.
Child lock function on the unit display panel.
Brightness level control of the display unit to reduce the led
light glow.
Automatic restart function in case of unexpected electricity supply
line power cuts.

UFV Physical data Indoor unit

Indoor unit HP C RAS-B10UFV-E1 RAS-B13UFV-E1 RAS-B18UFV-E1
Air Flow (max) m3/h - l/s C 468 - 130 510 - 142 600 - 167
Sound pressure level (h/l) dB(A) C 39/26 40/27 46/34
Sound power level (h) dB(A) H 54 55 61
Air Flow (max) m3/h - l/s H 510 - 142 552 - 153 642 - 178
Sound pressure level (h/l) dB(A) H 39/26 40/27 46/34
Sound power level (h) dB(A) 54 55 61
Dimensions (HxWxD) mm
Weight kg 600x700x220 600x700x220 600x700x220
Flare connections (gas - liquid) inch 16 16 16

3/8 - 1/4 3/8 - 1/4 1/2 - 1/4

C = cooling mode H = heating mode h/l= high / low speed

42

Indoor units combinations examples
2:1 3:1

RAS-2M18S3AV-E RAS-3M26S3AV

4:1 5:1

RAS-4M27S3AV-E RAS-5M34S3AV-E

Note: Differtent type of indoor units can be connected in the same system. Refer to the matching table to see the sizes available for each system combination.

43

Outdoor unit RAS-2M14S3AV-E Combination ratings (size 14) heat pump

Performances in Cooling mode Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
Operating status Unit A Unit B Unit A Unit B Min. Nom. Max.
07 07 Min. Nom. Max. 290 940 1130 Min. Nom. Max. Pdc SEER Class
2 unit operation 10 07 22 290 870 1130 4 6,55 A++
13 07 2,30 1,70 1,6 4 4,5 290 850 1140 1,64 4,36 5,22 4 6,58 A++
Performances in Heating mode 10 10 2,60 1,40 290 850 1140 4 6,65 A++
Operating status 13 10 1,6 4 4,6 290 840 1150 1,64 4,05 5,22 4 6,63 A++
13 13 22 290 830 1150 4 6,70 A++
2 unit operation 2,31 1,69 1,6 4 4,7 1,64 3,96 5,26 4 6,73 A++
22
1,6 4 4,7 1,64 3,96 5,26 SCOP Label
4,31 A+
1,6 4 4,8 1,64 3,91 5,31 4,33 A+
4,37 A+
1,6 4 4,9 1,64 3,87 5,31 4,35 A+
4,39 A+
Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A) 4,41 A+
Unit A Unit B Unit A Unit B Min. Nom. Max.
07 07 2,20 2,20 Min. Nom. Max. 240 920 1270 Min. Nom. Max. Pdh
10 07 2,63 1,77 250 910 1250 3,1
13 07 2,73 1,67 1,3 4,4 5,1 250 880 1250 1,36 4,27 5,84 3,1
10 10 2,20 2,20 250 890 1230 3,1
13 10 2,30 2,10 1,3 4,4 5,1 250 870 1230 1,42 4,23 5,75 3,1
13 13 2,20 2,20 250 850 1230 3,1
1,3 4,4 5,2 1,42 4,09 5,75 3,1

1,3 4,4 5,1 1,42 4,14 5,66

1,3 4,4 5,2 1,42 4,05 5,66

1,3 4,4 5,2 1,42 3,96 5,62

Outdoor unit RAS-2M18S3AV-E Combination ratings (size 18) heat pump

Performances in Cooling mode Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
Operating status
Unit A Unit B Unit A Unit B Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Pdc SEER Class
2 unit operation 4 6,59 A++
07 07 2,00 2,00 1,7 4,0 5,5 270 940 1700 1,53 4,36 7,75 4,7 6,62 A++
Performances in Heating mode 5,2 6,64 A++
Operating status 10 07 2,70 2,00 1,7 4,7 5,8 270 1260 1830 1,53 5,80 8,32 5,2 6,84 A++
5,2 6,62 A++
2 unit operation 13 07 3,38 1,82 1,7 5,2 5,9 270 1490 1840 1,53 6,82 8,37 5,2 6,69 A++
5,2 6,88 A++
16 07 3,60 1,60 1,7 5,2 6.2 270 1390 1870 1,53 6,37 8,50 5,2 6,76 A++
5,2 6,90 A++
10 10 2,60 2,60 1,7 5,2 5,9 270 1520 1840 1,53 6,95 8,37 5,2 6,98 A++

13 10 3,01 2,19 1,7 5,2 6,0 270 1480 1850 1,53 6,77 8,41 SCOP Label
4,19 A+
16 10 3,25 1,95 1,7 5,2 6,3 270 1370 1870 1,53 6,29 8,50 4,21 A+
4,32 A+
13 13 2,60 2,60 1,7 5,2 6,1 270 1430 1850 1,53 6,55 8,41 4,57 A+
4,31 A+
16 13 2,85 2,35 1,7 5,2 6,2 270 1340 1880 1,53 6,15 8,54 4,33 A+
4,59 A+
16 16 2,60 2,60 1,7 5,2 6,4 270 1300 1900 1,53 5,97 8,63 4,36 A+
4,6 A++
Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A) 4,98 A++
Min. Nom. Max.
Unit A Unit B Unit A Unit B 1,3 5,4 7,2 Min. Nom. Max. Min. Nom. Max. Pdh
1,3 5,4 7,2 3,2
07 07 2,70 2,70 1,3 5,4 7,5 240 1370 2240 1,36 6,29 10,14 3,2
1,3 5,4 7,5 3,2
10 07 3,34 2,26 1,3 5,4 7,3 250 1390 2200 1,42 6,37 9,96 3,2
1,3 5,4 7,5 3,2
13 07 3,64 1,96 1,3 5,4 7,5 250 1340 2250 1,42 6,15 10,18 3,2
1,3 5,4 7,5 3,2
16 07 3,76 1,84 1,3 5,4 7,5 240 1240 2090 1,36 5,71 9,47 3,2
1,3 5,4 7,5 3,2
10 10 2,80 2,80 250 1350 2160 1,42 6,20 9,78 3,2

13 10 3,11 2,49 250 1320 2210 1,42 6,06 10,01

16 10 3,24 2,36 240 1220 2070 1,36 5,62 9,38

13 13 2,80 2,80 250 1290 2170 1,42 5,93 9,83

16 13 2,93 2,60 240 1190 2020 1,36 5,48 9,16

16 16 2,80 2,80 240 1140 1910 1,36 5,26 8,68

44

Outdoor unit RAS-3M18S3AV Combination ratings (size 18) heat pump

Performances in Cooling mode Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
Operating status
Unit A Unit Β Unit C Unit A Unit Β Unit C Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Pdc SEER Class
3 unit operation
07 07 07 1,74 1,73 1,73 2,4 5,2 6,5 400 1220 1950 2,22 5,62 8,85 5,2 6,92 A++

10 07 07 2,10 1,55 1,55 2,4 5,2 6,5 400 1210 1950 2,22 5,57 8,85 4,7 6,91 A++

13 07 07 2,50 1,35 1,35 2,4 5,2 6,5 400 1200 1950 2,22 5,53 8,85 5,2 6,9 A++

16 07 07 2,76 1,22 1,22 2,4 5,2 6,5 400 1190 1950 2,22 5,48 8,85 5,2 6,84 A++

10 10 07 1,90 1,90 1,40 2,4 5,2 6,5 400 1200 1950 2,22 5,53 8,85 5,2 6,91 A++

13 10 07 2,29 1,67 1,24 2,4 5,2 6,5 400 1190 1950 2,22 5,48 8,85 5,2 6,89 A++

16 10 07 2,54 1,53 1,13 2,4 5,2 6,5 400 1180 1950 2,22 5,44 8,85 5,2 6,82 A++

13 13 07 2,05 2,05 1,10 2,4 5,2 6,5 400 1180 1950 2,22 5,44 8,85 5,2 6,87 A++

16 13 07 2,29 1,89 1,02 2,4 5,2 6,5 400 1170 1950 2,22 5,39 8,85 5,2 6,75 A++

10 10 10 1,74 1,73 1,73 2,4 5,2 6,5 400 1190 1950 2,22 5,48 8,85 5,2 6,9 A++

13 10 10 2,12 1,54 1,54 2,4 5,2 6,5 400 1180 1950 2,22 5,44 8,85 5,2 6,87 A++

16 10 10 2,36 1,42 1,42 2,4 5,2 6,5 400 1170 1950 2,22 5,39 8,85 5,2 6,8 A++

13 13 10 1,90 1,90 1,40 2,4 5,2 6,5 400 1170 1950 2,22 5,39 8,85 5,2 6,85 A++

Performances in Cooling mode Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)
Operating status
Unit A Unit Β Unit C Unit A Unit Β Unit C Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Pdh SCOP Label
3 unit operation
07 07 07 2.26 2,27 2,27 1,9 6,8 8,0 350 1700 2320 1,96 7,75 10,50 3,5 4,46 A++

10 07 07 2,90 1,95 1,95 1,9 6,8 8,0 350 1680 2290 1,96 7,66 10,36 3,5 4,47 A++

13 07 07 3,26 1,77 1,77 1,9 6,8 8,0 350 1650 2250 1,96 7,53 10,18 3,5 4,47 A++

16 07 07 3,44 1,68 1,68 1,9 6,8 8,0 340 1600 2150 1,91 7,30 9,74 3,5 4,61 A++

10 10 07 2,54 2,54 1,72 1,9 6,8 8,0 350 1660 2260 1,96 7,57 10,23 3,5 4,47 A++

13 10 07 2,91 2,32 1,57 1,9 6,8 8,0 350 1640 2220 1,96 7,48 10,05 3,5 4,43 A++

16 10 07 3,07 2,23 1,50 1,9 6,8 8,0 340 1590 2130 1,91 7,26 9,65 3,5 4,61 A++

13 13 07 2,68 2,68 1,44 1,9 6,8 8,0 350 1620 2190 1,96 7,39 9,92 3,5 4,42 A++

16 13 07 2,83 2,58 1,39 1,9 6,8 8,0 340 1580 2110 1,91 7,22 9,56 3,5 4,6 A++

10 10 10 2,26 2,27 2,27 1,9 6,8 8,0 350 1650 2230 1,96 7,53 10,10 3,5 4,46 A++

13 10 10 2,62 2,09 2,09 1,9 6,8 8,0 350 1620 2200 1,96 7,39 9,96 3,5 4,43 A++

16 10 10 2,78 2,01 2,01 1,9 6,8 8,0 330 1580 2090 1,85 7,22 9,47 3,5 4,6 A++

13 13 10 2,43 2,43 1,94 1,9 6,8 8,0 350 1620 2160 1,96 7,39 9,78 3,5 4,42 A++

45

Outdoor unit RAS-3M26S3AV-E Combination ratings (size 26) heat pump

Performances in Cooling mode Combination Unit C Unit cacacity (kW) Cooling capacity (kW) Power input (W) Operating current (A) SEER Class
Operating status Unit A Unit B 07 Unit A Unit B Unit C Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. 5,71 A+
07 07 07 2,00 2,00 2,00 3,8 6,0 8,4 950 1400 2720 4,59 6,41 12,07 5,86 A+
3 unit operation 10 07 07 2,70 2,00 2,00 3,8 6,7 8,4 950 1660 2720 4,59 7,60 12,07 5,92 A+
13 07 07 3,56 1,92 1,92 3,9 7,4 8,6 960 1975 2750 4,64 9,04 12,20 5,93 A+
16 07 07 3,92 1,74 1,74 3,9 7,4 8,6 960 1975 2750 4,64 9,04 12,20 5,89 A+
18 07 07 4,11 1,64 1,64 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,17 A++
22 07 07 4,44 1,48 1,48 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,16 A++
24 07 07 4,73 1,33 1,33 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,96 A+
10 10 07 2,70 2,70 2,00 3,8 7,4 8,4 950 1850 2720 4,59 8,47 12,07 5,92 A+
13 10 07 3,26 2,38 1,76 3,9 7,4 8,6 960 1975 2750 4,64 9,04 12,20 5,92 A+
16 10 07 3,62 2,17 1,61 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,89 A+
18 10 07 3,81 2,06 1,53 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,17 A++
22 10 07 4,15 1,87 1,38 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,16 A++
24 10 07 4,45 1,69 1,25 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,91 A+
13 13 07 2,91 2,91 1,57 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,92 A+
16 13 07 3,26 2,68 1,45 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,89 A+
18 13 07 3,46 2,56 1,38 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,17 A++
22 13 07 3,79 2,34 1,26 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,16 A++
24 13 07 4,10 2,14 1,16 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,05 A+
16 16 07 3,03 3,03 1,35 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,15 A++
18 16 07 3,22 2,90 1,29 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,18 A++
22 16 07 3,60 2,70 1,20 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,17 A++
24 16 10 3,92 2,48 1,10 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 5,92 A+
10 10 10 2,47 2,47 2,47 3,9 7,4 8,6 960 1975 2750 4,64 9,04 12,20 5,91 A+
13 10 10 3,01 2,20 2,20 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,92 A+
16 10 10 3,36 2,02 2,02 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,89 A+
18 10 10 3,56 1,92 1,92 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,17 A++
22 10 10 3,89 1,75 1,75 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,16 A++
24 10 10 4,20 1,60 1,60 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,91 A+
13 13 10 2,71 2,71 1,98 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 5,92 A+
16 13 10 3,06 2,51 1,83 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,02 A+
18 13 10 3,25 2,40 1,75 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,17 A++
22 13 10 3,63 2,24 1,63 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,17 A++
24 13 10 3,94 2,06 1,50 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,18 A++
16 16 10 2,85 2,85 1,71 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,15 A++
18 16 10 3,03 2,73 1,64 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,18 A++
22 16 10 3,41 2,56 1,53 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,17 A++
24 16 13 3,72 2,36 1,42 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 5,91 A+
13 13 13 2,47 2,47 2,47 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,05 A+
16 13 13 2,80 2,30 2,30 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,02 A+
18 13 13 2,98 2,21 2,21 4,0 7,4 8,8 970 1975 2770 4,69 9,04 12,29 6,17 A++
22 13 13 3,36 2,07 2,07 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,17 A++
24 13 13 3,67 1,91 1,91 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,19 A++
16 16 13 2,66 2,66 2,19 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,15 A++
18 16 13 2,84 2,56 2,10 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,18 A++
22 16 13 3,17 2,38 1,95 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,17 A++
24 16 16 3,48 2,21 1,81 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,19 A++
16 16 16 2,50 2,50 2,50 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,16 A++
18 16 16 2,68 2,41 2,41 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42 6,21 A++
22 16 3,00 2,25 2,25 4,1 7,5 9,0 980 2000 2800 4,73 9,15 12,42

46

Outdoor unit RAS-3M26S3AV-E Combination ratings (size 26) heat pump

Performances in Heating mode Combination Unit C Unit cacacity (kW) Cooling capacity (kW) Power input (W) Operating current (A) SEER Class
Operating status Unit A Unit B 07 Unit A Unit B Unit C Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. 4,41 A+
07 07 07 2,70 2,70 2,70 2,0 8,1 10,8 380 1800 2750 2,07 8,24 12,20 4,41 A+
3 unit operation 10 07 07 3,53 2,38 2,38 2,0 8,3 10,8 380 1900 2750 2,07 8,70 12,20 4,41 A+
13 07 07 4,28 2,31 2,31 2,0 8,9 10,8 380 2175 2750 2,07 9,95 12,20 4,41 A+
16 07 07 4,49 2,20 2,20 2,0 8,9 10,8 380 2175 2750 2,07 9,95 12,20 4,41 A+
18 07 07 4,68 2,11 2,11 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,27 A+
22 07 07 5,02 1,94 1,94 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
24 07 07 5,34 1,78 1,78 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
10 10 07 3,18 3,18 2,14 2,0 8,5 10,8 380 2000 2750 2,07 9,15 12,20 4,41 A+
13 10 07 3,80 3,04 2,05 2,0 8,9 10,8 380 2175 2750 2,07 9,95 12,20 4,41 A+
16 10 07 4,01 2,92 1,97 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 10 07 4,20 2,80 1,89 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,27 A+
22 10 07 4,55 2,60 1,75 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
24 10 07 4,87 2,41 1,62 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
13 13 07 3,50 3,50 1,89 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
16 13 07 3,71 3,37 1,82 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 13 07 3,90 3,25 1,75 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
22 13 07 4,24 3,03 1,63 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
24 13 07 4,56 2,82 1,52 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
16 16 07 3,57 3,57 1,75 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 16 07 3,76 3,45 1,69 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,27 A+
22 16 07 4,14 3,26 1,60 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,26 A+
24 16 10 4,47 3,04 1,49 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,41 A+
10 10 10 2,97 2,97 2,97 2,0 8,9 10,8 380 2175 2750 2,07 9,95 12,20 4,41 A+
13 10 10 3,42 2,74 2,74 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
16 10 10 3,63 2,64 2,64 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 10 10 3,81 2,54 2,54 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,27 A+
22 10 10 4,15 2,37 2,37 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
24 10 10 4,48 2,21 2,21 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
13 13 10 3,18 3,18 2,54 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
16 13 10 3,38 3,07 2,46 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 13 10 3,56 2,97 2,37 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
22 13 10 3,94 2,81 2,25 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,26 A+
24 13 10 4,26 2,63 2,11 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,41 A+
16 16 10 3,26 3,26 2,37 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 16 10 3,45 3,16 2,30 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,27 A+
22 16 10 3,82 3,00 2,18 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,26 A+
24 16 13 4,14 2,81 2,05 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,41 A+
13 13 13 2,97 2,97 2,97 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
16 13 13 3,16 2,87 2,87 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,41 A+
18 13 13 3,34 2,78 2,78 2,0 8,9 11,0 380 2175 2830 2,07 9,95 12,56 4,26 A+
22 13 13 3,71 2,65 2,65 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,26 A+
24 13 13 4,03 2,49 2,49 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,41 A+
16 16 13 3,09 3,09 2,81 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,41 A+
18 16 13 3,27 3,00 2,73 2.0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,27 A+
22 16 13 3,60 2,83 2,57 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,26 A+
24 16 16 3,92 2,66 2,42 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,42 A+
16 16 16 3,00 3,00 3,00 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,42 A+
18 16 16 3,18 2,91 2,91 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87 4,27 A+
22 16 3,50 2,75 2,75 2,0 9,0 11,2 380 2200 2900 2,07 10,07 12,87

47

Outdoor unit RAS-4M27S3AV-E Combination ratings (size 27) heat pump

Performances in Cooling mode Combination Unit C Unit D Unit capacity (kW) Unit D Cooling capacity (kW) Power input (W) Operating current (A) SEER Class
Operating status Unit A Unit B 07 07 Unit A Unit B Unit C 1,78 Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. 6,00 A+
07 07 07 07 1,78 1,78 1,78 1,72 4,0 7,1 8,6 850 2029 2620 4,11 9,29 11,62 6,06 A+
4 unit operation 10 07 07 07 2,33 1,72 1,72 1,57 4,0 7,5 8,7 890 2143 2640 4,30 9,81 11,71 6,06 A+
13 07 07 07 2,90 1,57 1,57 1,47 4,1 7,6 8,9 900 2171 2700 4,35 9,94 11,98 6,08 A+
16 07 07 07 3,30 1,47 1,47 1,42 4,1 7,7 9,0 930 2200 2730 4,49 10,07 12,11 6,07 A+
18 07 07 07 3,55 1,42 1,42 1,32 4,1 7,8 9,1 930 2229 2760 4,49 10,20 12,24 6,10 A++
22 07 07 07 3,95 1,32 1,32 1,21 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,09 A+
24 07 07 07 4,28 1,21 1,21 1,62 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,06 A+
10 10 07 07 2,18 2,18 1,62 1,48 4,1 7,6 8,9 900 2171 2700 4,35 9,94 11,98 6,08 A+
13 10 07 07 2,74 2,00 1,48 1,39 4,1 7,7 9,0 930 2200 2730 4,49 10,07 12,11 6,10 A++
16 10 07 07 3,13 1,88 1,39 1,35 4,1 7,8 9,1 930 2229 2760 4,49 10,20 12,24 6,08 A+
18 10 07 07 3,38 1,82 1,35 1,24 4,1 7,9 9,2 940 2257 2790 4,54 10,33 12,38 6,10 A++
22 10 07 07 3,73 1,68 1,24 1,14 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,09 A+
24 10 07 07 4,06 1,55 1,14 1,39 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,11 A++
13 13 07 07 2,56 2,56 1,39 1,30 4,1 7,9 9,2 940 2257 2790 4,54 10,33 12,38 6,10 A++
16 13 07 07 2,91 2,40 1,30 1,24 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,07 A+
18 13 07 07 3,11 2,30 1,24 1,15 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
22 13 07 07 3,46 2,13 1,15 1,07 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,09 A+
24 13 07 07 3,79 1,98 1,07 1,22 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,11 A++
16 16 07 07 2,73 2,73 1,22 1,17 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
18 16 07 07 2,93 2,63 1,17 1,13 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,05 A+
18 18 10 07 2,82 2,82 1,13 1,50 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,06 A+
10 10 10 07 2,03 2,03 2,03 1,41 4,1 7,6 8,9 900 2171 2700 4,35 9,94 11,98 6,09 A+
13 10 10 07 2,60 1,90 1,90 1,33 4,1 7,8 9,1 930 2229 2760 4,49 10,20 12,24 6,11 A++
16 10 10 07 2,99 1,79 1,79 1,27 4,1 7,9 9,2 940 2257 2790 4,54 10,33 12,38 6,07 A+
18 10 10 07 3,19 1,72 1,72 1,18 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
22 10 10 07 3,54 1,59 1,59 1,09 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,09 A+
24 10 10 07 3,87 1,47 1,47 1,31 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
13 13 10 07 2,42 2,42 1,76 1,22 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
16 13 10 07 2,76 2,27 1,65 1,18 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,07 A+
18 13 10 07 2,95 2,18 1,59 1,11 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,11 A++
22 13 10 07 3,33 2,06 1,50 1,03 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,10 A++
24 13 10 07 3,66 1,91 1,39 1,15 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,11 A++
16 16 10 07 2,59 2,59 1,56 1,11 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,08 A+
18 16 10 07 2,78 2,50 1,50 1,09 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,06 A+
18 18 13 07 2,72 2,72 1,47 1,21 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,10 A++
13 13 13 07 2,23 2,23 2,23 1,14 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
16 13 13 07 2,56 2,10 2,10 1,10 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,07 A+
18 13 13 07 2,74 2,03 2,03 1,09 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,12 A++
16 16 13 07 2,45 2,45 2,01 1,05 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,09 A+
18 16 10 10 2,63 2,37 1,95 1,98 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,11 A++
10 10 10 10 1,98 1,98 1,98 1,81 4,1 7,9 9,2 940 2257 2790 4,54 10,33 12,38 6,11 A++
13 10 10 10 2,48 1,81 1,81 1,69 4,1 7,9 9,2 940 2257 2790 4,54 10,33 12,38 6,10 A++
16 10 10 10 2,82 1,69 1,69 1,63 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,07 A+
18 10 10 10 3,02 1,63 1,63 1,53 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,11 A++
22 10 10 10 3,40 1,53 1,53 1,42 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,10 A++
24 10 10 10 3,74 1,42 1,42 1,67 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,10 A++
13 13 10 10 2,28 2,28 1,67 1,57 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,10 A++
16 13 10 10 2,61 2,15 1,57 1,50 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,12 A++
16 16 10 10 2,50 2,50 1,50 1,51 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,07 A+
18 13 10 10 2,80 2,07 1,51 1,45 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,09 A+
18 16 13 10 2,68 2,42 1,45 1,55 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,10 A++
13 13 13 10 2,12 2,12 2,12 1,48 4,2 7,9 9,3 950 2257 2820 4,59 10,33 12,51 6,12 A++
16 13 13 10 2,47 2,03 2,03 1,43 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,09 A+
18 13 13 13 2,65 1,96 1,96 2,00 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51 6,11 A++
13 13 2,00 2,00 2,00 4,2 8,0 9,3 950 2286 2820 4,59 10,46 12,51

48

Outdoor units RAS-4M27S3AV-E Combination ratings (size 27) heat pump

Performances in Heating mode Combination Unit C Unit D Unit capacity (kW) Unit D Cooling capacity (kW) Power input (W) Operating current (A) SEER Class
Operating status Unit A Unit B 07 07 Unit A Unit B Unit C 2,09 Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. 4,24 A+
07 07 07 07 2,09 2,09 2,09 1,89 2,9 8,4 11,5 501 1792 2560 2,42 8,20 11,36 4,24 A+
4 unit operation 10 07 07 07 2,80 1,89 1,89 1,78 2,9 8,5 11,5 501 1812 2560 2,42 8,29 11,36 4,24 A+
13 07 07 07 3,30 1,78 1,78 1,73 2,9 8,6 11,6 501 1850 2580 2,42 8,47 11,45 4,24 A+
16 07 07 07 3,53 1,73 1,73 1,69 2,9 8,7 11,6 501 1869 2580 2,42 8,55 11,45 4,24 A+
18 07 07 07 3,75 1,69 1,69 1,59 2,9 8,8 11,6 501 1889 2580 2,42 8,65 11,45 4,10 A+
22 07 07 07 4,13 1,59 1,59 1,48 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,10 A+
24 07 07 07 4,45 1,48 1,48 1,74 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,24 A+
10 10 07 07 2,58 2,58 1,74 1,64 2,9 8,6 11,6 501 1850 2580 2,42 8,47 11,45 4,24 A+
13 10 07 07 3,03 2,43 1,64 1,60 2,9 8,7 11,6 501 1869 2580 2,42 8,55 11,45 4,24 A+
16 10 07 07 3,26 2,37 1,60 1,56 2,9 8,8 11,6 501 1889 2580 2,42 8,65 11,45 4,24 A+
18 10 07 07 3,47 2,31 1,56 1,47 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,10 A+
22 10 07 07 3,80 2,17 1,47 1,37 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,10 A+
24 10 07 07 4,12 2,03 1,37 1,56 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,23 A+
13 13 07 07 2,89 2,89 1,56 1,51 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 13 07 07 3,08 2,80 1,51 1,47 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 13 07 07 3,26 2,71 1,47 1,38 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,10 A+
22 13 07 07 3,58 2,56 1,38 1,30 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,10 A+
24 13 07 07 3,90 2,41 1,30 1,47 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,24 A+
16 16 07 07 2,98 2,98 1,47 1,42 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 16 07 07 3,16 2,90 1,42 1,38 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 18 10 07 3,07 3,07 1,38 1,59 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
10 10 10 07 2,35 2,35 2,35 1,52 2,9 8,6 11,6 501 1850 2580 2,42 8,47 11,45 4,24 A+
13 10 10 07 2,81 2,25 2,25 1,48 2,9 8,8 11,6 501 1889 2580 2,42 8,65 11,45 4,24 A+
16 10 10 07 3,02 2,20 2,20 1,44 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 10 10 07 3,20 2,13 2,13 1,36 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,10 A+
22 10 10 07 3,52 2,01 2,01 1,28 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,10 A+
24 10 10 07 3,83 1,89 1,89 1,44 2,6 8,9 11,7 480 1905 2600 2,32 8,72 11,54 4,23 A+
13 13 10 07 2,66 2,66 2,13 1,40 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 13 10 07 2,85 2,59 2,07 1,36 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 13 10 07 3,02 2,51 2,01 1,30 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,10 A+
22 13 10 07 3,37 2,41 1,93 1,23 2,6 9,0 11,7 480 1927 2600 2,32 8,82 11,54 4,10 A+
24 13 10 07 3,68 2,27 1,82 1,36 2,6 9,0 11,7 480 1927 2600 2,32 8,82 11,54 4,24 A+
16 16 10 07 2,77 2,77 2,01 1,32 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 16 10 07 2,93 2,69 1,96 1,30 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 18 13 07 2,89 2,89 1,93 1,36 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,23 A+
13 13 13 07 2,51 2,51 2,51 1,32 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 13 13 07 2,69 2,45 2,45 1,29 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 13 13 07 2,86 2,38 2,38 1,30 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 16 13 07 2,65 2,65 2,41 1,27 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,24 A+
18 16 10 10 2,81 2,58 2,34 2,18 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,24 A+
10 10 10 10 2,18 2,18 2,18 2,09 2,9 8,7 11,6 501 1869 2580 2,42 8,55 11,45 4,24 A+
13 10 10 10 2,62 2,09 2,09 2,03 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 10 10 10 2,80 2,03 2,03 1,98 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 10 10 10 2,97 1,98 1,98 1,89 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,10 A+
22 10 10 10 3,32 1,89 1,89 1,79 2,6 9,0 11,7 480 1927 2600 2,32 8,82 11,54 4,10 A+
24 10 10 10 3,63 1,79 1,79 1,98 2,6 9,0 11,7 480 1927 2600 2,32 8,82 11,54 4,23 A+
13 13 10 10 2,47 2,47 1,98 1,92 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 13 10 10 2,65 2,41 1,92 1,89 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 16 10 10 2,61 2,61 1,89 1,87 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,24 A+
18 13 10 10 2,81 2,34 1,87 1,85 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
18 16 13 10 2,77 2,54 1,85 1,87 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,23 A+
13 13 13 10 2,34 2,34 2,34 1,85 2,9 8,9 11,7 501 1905 2600 2,42 8,72 11,54 4,24 A+
16 13 13 10 2,54 2,31 2,31 1,80 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,24 A+
18 13 13 13 2,70 2,25 2,25 2,25 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54 4,23 A+
13 13 2,25 2,25 2,25 2,9 9,0 11,7 501 1927 2600 2,42 8,82 11,54

49

Outdoor unit RAS-5M34S3AV-E Combination ratings (size 34) heat pump

Performances in Cooling mode

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)
5 unit operation
Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. SEER Class
50
07 07 07 07 07 1,96 1,96 1,96 1,96 1,96 3,7 9,8 10,8 950 2917 3630 4,59 13,35 16,10 6,28 A++
10 07 07 07 07 2,50 1,85 1,85 1,85 1,85 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
13 07 07 07 07 3,13 1,69 1,69 1,69 1,69 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 07 07 07 07 3,56 1,58 1,58 1,58 1,58 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 07 07 07 07 3,81 1,52 1,52 1,52 1,52 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
10 10 07 07 07 2,34 2,34 1,74 1,74 1,74 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
13 10 07 07 07 2,95 2,16 1,60 1,60 1,60 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 10 07 07 07 3,38 2,03 1,50 1,50 1,50 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 10 07 07 07 3,61 1,95 1,45 1,45 1,45 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
13 13 07 07 07 2,73 2,73 1,48 1,48 1,48 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 07 07 07 3,14 2,58 1,39 1,39 1,39 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 13 07 07 07 3,37 2,49 1,35 1,35 1,35 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
16 16 07 07 07 2,97 2,97 1,32 1,32 1,32 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 16 07 07 07 3,19 2,87 1,28 1,28 1,28 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
10 10 10 07 07 2,21 2,21 2,21 1,64 1,64 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
13 10 10 07 07 2,80 2,04 2,04 1,51 1,51 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
13 13 10 07 07 2,60 2,60 1,90 1,40 1,40 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 10 10 07 07 3,21 1,92 1,92 1,42 1,42 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 10 10 07 07 3,44 1,86 1,86 1,38 1,38 3,7 9,9 10.9 950 2946 3670 4,59 13,48 16,28 6,27 A++
13 13 13 07 07 2,43 2,43 2,43 1,31 1,31 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 13 07 07 2,80 2,30 2,30 1,25 1,25 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 13 13 07 07 3,02 2,23 2,23 1,21 1,21 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
16 16 10 07 07 2,84 2,84 1,70 1,26 1,26 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 16 10 07 07 3,06 2,75 1,65 1,22 1,22 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
16 16 13 07 07 2,67 2,67 2,19 1,19 1,19 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 16 13 07 07 2,88 2,59 2,13 1,15 1,15 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
10 10 10 10 07 2,09 2,09 2,09 2,09 1,55 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
13 10 10 10 07 2,65 1,94 1,94 1,94 1,43 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 10 10 10 07 3,05 1,83 1,83 1,83 1,36 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 10 10 10 07 3,28 1,77 1,77 1,77 1,31 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
13 13 10 10 07 2,48 2,48 1,81 1,81 1,34 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 10 10 07 2,86 2,35 1,71 1,71 1,27 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 13 10 10 07 3,07 2,28 1,66 1,66 1,23 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
16 16 10 10 07 2,72 2,72 1,63 1,63 1,21 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
13 13 13 10 07 2,32 2,32 2,32 1,69 1,25 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 13 10 07 2,68 2,21 2,21 1,61 1,19 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
16 16 13 10 07 2,56 2,56 2,11 1,54 1,14 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
13 13 13 13 07 2,18 2,18 2,18 2,18 1,18 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 13 13 07 2,53 2,08 2,08 2,08 1,13 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
16 16 13 13 07 2,42 2,42 1,99 1,99 1,08 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
10 10 10 10 10 1,98 1,98 1,98 1,98 1,98 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
13 10 10 10 10 2,53 1,84 1,84 1,84 1,84 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 10 10 10 10 2,91 1,75 1,75 1,75 1,75 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 10 10 10 10 3,13 1,69 1,69 1,69 1,69 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
13 13 10 10 10 2,36 2,36 1,72 1,72 1,72 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 10 10 10 2,73 2,25 1,64 1,64 1,64 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 13 10 10 10 2,95 2,18 1,59 1,59 1,59 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
16 16 10 10 10 2,61 2,61 1,56 1,56 1,56 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
13 13 13 10 10 2,22 2,22 2,22 1,62 1,62 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 13 10 10 2,58 2,12 2,12 1,55 1,55 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,30 A++
18 13 13 10 10 2,78 2,06 2,06 1,50 1,50 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,27 A++
16 16 13 10 10 2,49 2,49 2,04 1,49 1,49 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,31 A++
13 13 13 13 10 2,09 2,09 2,09 2,09 1,53 3,7 9,9 10,9 950 2946 3670 4,59 13,48 16,28 6,29 A++
16 13 13 13 10 2,46 2,02 2,02 2,02 1,48 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,31 A++
18 13 13 13 10 2,66 1,97 1,97 1,97 1,44 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,28 A++
16 16 13 13 10 2,36 2,36 1,94 1,94 1,41 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,31 A++
13 13 13 13 13 2,00 2,00 2,00 2,00 2,00 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,31 A++
16 13 13 13 13 2,33 1,92 1,92 1,92 1,92 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,31 A++
22 07 07 07 07 4,24 1,41 1,41 1,41 1,41 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 10 07 07 07 4,04 1,82 1,35 1,35 1,35 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 10 10 07 07 3,86 1,74 1,74 1,29 1,29 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 10 10 10 07 3,69 1,66 1,66 1,66 1,23 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 10 10 10 10 3,54 1,59 1,59 1,59 1,59 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 13 07 07 07 3,78 2,33 1,26 1,26 1,26 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 13 10 07 07 3,62 2,23 1,63 1,21 1,21 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 13 10 10 07 3,47 2,14 1,56 1,56 1,16 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 13 10 10 10 3,37 2,08 1,52 1,52 1,52 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,30 A++
22 13 13 07 07 3,41 2,11 2,11 1,14 1,14 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
22 13 13 10 07 3,31 2,04 2,04 1,49 1,10 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,30 A++
22 13 13 10 10 3,19 1,97 1,97 1,44 1,44 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,30 A++
22 13 13 13 07 3,14 1,94 1,94 1,94 1,05 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,30 A++
24 07 07 07 07 4,65 1,31 1,31 1,31 1,31 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 10 07 07 07 4,45 1,69 1,25 1,25 1,25 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 10 10 07 07 4,26 1,62 1,62 1,20 1,20 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 10 10 10 07 4,09 1,55 1,55 1,55 1,15 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 10 10 10 10 3,93 1,49 1,49 1,49 1,49 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 13 07 07 07 4,18 2,18 1,18 1,18 1,18 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 13 10 07 07 4,02 2,09 1,53 1,13 1,13 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 13 10 10 07 3,86 2,01 1,47 1,47 1,09 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++
24 13 10 10 10 3,76 1,96 1,43 1,43 1,43 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,30 A++
24 13 13 07 07 3,80 1,98 1,98 1,07 1,07 3,7 9,9 11,0 950 2946 3700 4,59 13,48 16,42 6,29 A++

24 13 13 10 07 3,70 1,93 1,93 1,41 1,04 3,7 10,0 11,0 950 2980 3700 4,59 13,64 16,42 6,30 A++


Click to View FlipBook Version