Thank You for Trusting Us
At Striem, we make three things: oil separators, solids interceptors, and chemical waste tanks. If we don’t make them right, we have nothing
to fall back on. This tends to keep us very sharp.
Whether you’re specifying, buying, installing, or maintaining one of our products, we thank you for trusting us.
We want to make a promise. If you call us, we will provide best-in-class customer service. If you interact with our product, it will be easy.
If you think we didn’t hold up our end of the bargain, call us and we’ll make it right.
Vince Ismert Gabe Ismert
Direct: 816-591-9765 Direct: 816-820-5454
100% American Made Lifetime Guarantee
If you want to speak to the fabricator who built your product, call Our polyethylene products are designed to last the lifetime of the
us. If you want to meet him or her, drop by our factory. All of our plumbing system in which they are installed. If they don't, we will
products are 100% American made, now and forever. repair or replace them at no charge. Product damage due to normal
wear and tear may be repaired or replaced at a reasonable charge.
www.striemco.com | Made in the USA | Striem Catalog
Table of Contents specifications & submittals
Oil Separators formats PDF DOC DWG RFA
available
online
Oil Reserve™ oil/sand separators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Oil Reserve™ oil collection tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Solids Interceptors
HLT/B and USI Series under counter solids interceptors . . . . . . . . . . . . . . . . . . . . . . . . . 12
Aardvark™ basket style solids interceptors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Prospector™ screen style solids interceptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Settler™ catch basins for sand and sediment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Chemical Waste Tanks
Lab Rat™ under counter neutralization tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Lab Basin™ neutralization tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
NT Series neutralization tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Command Center™ pH monitoring package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Bio Basin™ decontamination tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Appendix
Terms and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Talk to a Human
8:00 a.m. – 5:00 p.m. CST (Monday through Friday)
Tel: 913-222-1500
email: [email protected] | [email protected]
www.striemco.com | Made in the USA | Striem Catalog 2
Oil Reserve™ Product Selection
sizing guidelines
Oil Reserve™ Oil/Sand Separators incorporate patented Diffusion Flow™ technology to maximize
oil and sand separation. Petroleum based oils are typically lighter than water and will quickly rise
to the surface by gravity differential separation according to Stokes' Law.
Common Specific Gravities
The following chart is provided for reference only. Specific gravities less than 1 float
while those greater than 1 sink.
substance specific gravity substance specific gravity
Gasoline A 0.74 Chicken Fat 0.924
Petroleum Oil 0.82 Fish Oil 0.928
Hydraulic Fluid 0.86 Water 1
Butter 0.87 Freon 11 1.49
Lard 0.875 Mud 1.73
Olive Oil 0.91 Sand 1.92
Vegetable Oil 0.92
Option 1: size by drainage area for service facilities
When allowed, use the following sizing chart where motor vehicles are serviced and/or stored. For parking-only areas, consider option 2.
Oil Separator Sizing Chart
square feet of drainage area required capacity: cubic feet required capacity: gallons recommended model
Up to 200 Up to 7 52 OS-50
OS-75
>200 – 1,100 Up to 16 120 OS-100
OS-100 (2 in series)
>1,100 – 3,100 Up to 36 269 OS-750
OS-1000
>3,100 – 6,700 Up to 72 539 OS-1500
>6,700 – 9,500 Up to 100 750
>9,500 – 12,900 Up to 134 1,000
>12,900 – 19,500 Up to 200 1,500
Review plumbing code and locally adopted ordinances for specific requirements.
Option 2: size by flow rate for parking only facilities
Consider drain / hose bib flow rates when sizing for applications where motor vehicles are neither serviced nor stored (parking-only areas).
Drain Line Flow Rates (GPM) by Pipe Size* Hose Bib Flow Rates
pipe size (nominal) half pipe flow (design flow) maximum full pipe flow velocity ½ ¾
6.64 GPM
2 9.67 19.44 4 Ft./sec 3.77 GPM 9.96 GPM
3 29.33 58.67 13.29 GPM
4 62.96 125.77 6 Ft./sec 5.66 GPM 16.61 GPM
6 187.74 375.47
8 Ft./sec 7.54 GPM
preferred flow rate
10 Ft./sec 9.43 GPM
* ¼" pitch slope based on Manning’s Formula with friction factor N=0.012"
3 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Option 3: size by flow rate for elevator pits
ASME A17.1-2007/CSA B44-07 is the Safety Code for Elevators and Escalators.
It intended to serve as the basis for the design construction, installation,
operation, testing, inspection, maintenance, alteration and repair of elevators,
dumbwaiters, escalators, moving walks and material lifts. Section 2.2 details
the requirements for pits for all elevators governed by the code. 2.2.2.3
mandates that permanent provision be made to prevent accumulation of ground
water in the pit, while 2.2.2.4 requires the necessary floor drain or sump pump
meet the applicable plumbing code for the jurisdiction. 2.2.2.5 requires all
elevators with Firefighters’ Emergency Operation to have a drain or sump pump.
A sump pump or drain shall have the capacity to remove 3,000 gallons per hour
(50 gpm) per elevator.
IPC mandates the installation of an oil separator for hydraulic elevator pits,
unless there is an approved alarm system installed. The intent of the code is to
prevent an oil discharge to the sanitary drainage system. Some manufacturers
produce a specially fitted sump pump with an oil sensor and alarm unit which
functions to shut off the pump if oil is detected in the pit. For elevators with
Firefighters’ Emergency Operation the pit must be kept clear of accumulated
water as required in ASME A17.1-2007/CSA B44-07 section 2.2.2.5. However,
it may be possible for a sump pump with an oil sensor to shut off during a fire
allowing the pit to fill with sprinkler water undermining a firefighting operation.
The installation of an oil interceptor downstream of a sump pump satisfies both
the elevator and plumbing codes.
Sizing Guidelines Following an Elevator Sump
First, select an oil separator that meets the pump flow rate. Then, choose an oil separator with an oil capacity that is equal to or greater
than the worst possible discharge of hydraulic fluid.
application pump flow (GPM) OS model OS flow rate (GPM) OS oil capacity (gal.)
Single Elevator A 50 OS-50 50 34.1
Single Elevator B 50 OS-75 75 84.4
Double Elevator 100 OS-100 100 147.5
Review plumbing code and locally adopted ordinances for specific requirements.
Single Elevator A Single Elevator B Double Elevator
VENT VENT VENT
PIT PIT PIT PIT OS-100
OS-50 OS-75 SUMP
SUMP SUMP
NOTE: all pump fed oil separators should be specified with Clean Sweep™ coalescing media (as shown above) due to emulsification of oil.
www.striemco.com | Made in the USA | Striem Catalog 4
Oil Reserve™
oil/sand separators
With a standard lifetime warranty and OS-100 OS-75
several innovative installation features, OS-50 OS-35
the Oil Reserve™ stands alone as the
most versatile oil/sand separator series. OS-15 OS-25
Features: above grade or buried installations
| easy to carry HDPE design | TeleGlide™ field
adjustable risers | models OS-50 through OS-100
suitable for exterior installations | Two built-in
vent locations
Oil Reserve™ Covers
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
indoor covers outdoor cover
16" 24" 24" 24"
BOLTED BOLTED BOLTED PICKABLE CAST
POLYPROPYLENE COMPOSITE COMPOSITE – TRAFFIC IRON – H20 (optional)
OS-15, OS-25 OS-35, OS-50 OS-50 (optional), OS-50, OS-75, OS-100
2,000 lbs. pedestrian load rating 2,000 lbs. pedestrian load rating OS-75, OS-100 16,000 lbs. H20 load rating
16,000 lbs. highway load rating
Clean Sweep™ Coalescing Media (optional)
When oily wastewater is mechanically Clean Sweep™ polypropylene
emulsified (as in pump applications), oils
break into smaller, less buoyant droplets coalescing media has been
and decrease separator efficiency.
Coalescing media provides increased third party tested to
surface area for emulsified oil droplets to
merge into larger, more buoyant droplets, performance standard CEN EN858-1 for
greatly improving separator efficiency.
class 1 coalescing separators. The Clean
Specify Clean Sweep™ coalescing media
with select Oil Reserve™ Series models Sweep™ will render effluent quality to no
(OS-35, OS-50, OS-75, OS-100) to
significantly improve the separation of more than 5 mg/L (parts per million) up
mechanically emulsified oils.
to the following flow rates: Flow Rate:
OS-35 (with single media) 15 GPM
OS-50 (with single media) 15 GPM
OS-75 (with single media) 30 GPM
OS-100 (with single media) 45 GPM
OS-100 (with double media) 90 GPM
Efficiency may decrease at higher flow rates.
5 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Specifications
Capacity Pipe Sizes Rough-in Dimensions (in.) Weight (lbs.)
Striem Flow Oil Sand Liquid Plain End Optional Vent Body Inlet/Outlet Vent optional oil Vent/ Adapter Dry Wet
Model Rate (gal.) (gal.) (gal.) SCH.40 Male WH AB CD draw-off draw-off Adjust-
(GPM) Std. Optional Thread EF ability
(add to
L G B, D & H)
OS-15 15 10.1 3.9 16 2 3 2, 3 3 25 19 14 ¼ 10 4 ¼ 11 ¼ 3 n/a n/a 5 ½ n/a 28 160
OS-25 25 10.3 6.4 22 3 2 2, 3 3 27 21 15 10 ¾ 4 ¼ 11 ½ 3 ½ n/a n/a 6 ¼ n/a 31 215
OS-35 35 19.5 9.5 35 3 2, 4 2, 3, 4 3 33 25 25 15 10 17 8 n/a n/a 7 ½ 3 ½ 77 369
OS-50 50 34.1 12.5 52 4 3 3, 4 3 37 28 28 ½ 18 10 ½ 20 8 ½ 6 ½ 22 9 3 ½ 92 525
OS-75 75 84.4 19.2 125 4 6 4, 6 3 46 32 38 ½ 26 12 ½ 28 ½ 10 21 ½ 17 12 6 130 1,171
OS-100 100 147.5 105 275 4 6 4, 6 3 68 33 ½ 51 ½ 38 13 ½ 40 11 ½ 31 20 ½ 16 6 230 2,520
OS-15 OS-25 OS-35 OS-50 OS-75 OS-100
INLET-AIR RELIEF, OUTLET CLOSED TO PROVIDE SEWER GAS SEAL
Miscellaneous Options TeleGlide™ Riser Order Guide
*Upgrade to Highway *Upgrade to H-20 Desired Riser Height (in.)
Striem High Water Rated Bolted Rated Pickable Cast OS-15 OS-35 OS-75 Risers Needed
Model Anchor Kit Composite Cover Iron Cover OS-25 OS-50 OS-100 16 Series
Part # Part # Part # >2 1 ⁄8 - 16 n/a n/a Riser (SR-16)
OS-15 n/a n/a n/a n/a 0 - 3½ 0-6 24 Series Adapter
OS-25 n/a n/a
OS-35 n/a n/a
OS-50 AK1 n/a
n/a n/a >3½ - 22 >6 - 24 24 Series
OS-75 AK1 Short Riser (SR24)
OS-100 AK1 C24-H n/c C24-HP n/c
included C24-HP n/c n/a >22 - 37 >24 - 39 24 Series
included Long Riser (LR24)
C24-HP (2) n/c
Clean Sweep Coalescing Media Part # Compatible with Model(s) n/a n/a >39 - 43 24 Series Short +
CS1 (single media) 0S-35 / 0S-50 Short (SR24 + SR24)
CS2 (single media) 0S-75
CS3 (single media) 0S-100 n/a n/a >43 - 58 24 Series Short +
Long (SR24 + LR24)
CS6 (double media) 0S-100
n/a n/a >58 - 72 24 Series Long +
Long (LR24 + LR24)
DO2: Optional 2" Oil Draw-off Arm required when ordered with
Oil Reserve™ oil collection tank.
* When ordered with oil separator.
NOTE 1: OS-100 has two covers requiring a set of two TeleGlide™ risers when ordered.
NOTE 2: When upgraded covers are purchased separately, the full price will apply.
www.striemco.com | Made in the USA | Striem Catalog 6
OS-750 OS-1000
Specifications Specifications
Inlet/Outlet Max Flow Rate Max Operating Inlet/Outlet Max Flow Rate Max Operating
6" 314 GPM Temperature 6" 314 GPM Temperature
Liquid Capacity Oil Capacity 190°F Liquid Capacity Oil Capacity 190°F
750 (gal.) 387 (gal.) 1,000 (gal.) 440 (gal.)
Solids/Sediment Solids/Sediment
Capacity Capacity
306 (gal.) 347 (gal.)
Unit Weight w/Std. Covers Unit Weight w/Std. Covers
1,200 (lbs.) 1,400 (lbs.)
Highway rated, bolted, gas/water tight composite Highway rated, bolted, gas/water tight composite
covers (16,000 lbs.) covers (16,000 lbs.)
Side View Side View
Options Options
Teleglide field adjustable risers for extending covers to grade Teleglide field adjustable risers for extending covers to grade
H20 rated pickable cast iron covers H20 rated pickable cast iron covers
4" Plain end connections 4" Plain end connections
8" Plain end connections 8" Plain end connections
Male pipe thread connections Male pipe thread connections
7 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
OS-1500
Specifications Notes (OS-750, OS-1000, OS-1500)
Inlet/Outlet Max Flow Rate Max Operating 1. 1" thick seamless high density polyethylene walls.
6" 314 GPM Temperature 2. Unit supplied with built-in adapter(s) for up to 6" of adjustability.
Liquid Capacity Oil Capacity 190°F Additional riser(s) available for deeper burial depth.
1,500 (gal.) 616 (gal.) 3. Cover placement allows full access to tank for proper
Solids/Sediment
Capacity maintenance.
4. For buried applications.
485 (gal.)
Unit Weight w/Std. Covers
1,00 (lbs.)
Highway rated, bolted, gas/water tight composite
covers (16,000 lbs.)
Side View TeleGlide™ Riser Order Guide
Desired Riser Height (in.) Risers Needed
OS-750, OS-1000, OS-1500
16 Series
n/a Riser (SR-16)
0-6 24 Series Adapter
>6 - 24
>24 - 39 24 Series
>39 - 43 Short Riser (SR24)
>43 - 58
>58 - 72 24 Series
Long Riser (LR24)
24 Series Short +
Short (SR24 + SR24)
24 Series Short +
Long (SR24 + LR24)
24 Series Long +
Long (LR24 + LR24)
Options
Teleglide field adjustable risers for extending covers to grade
H20 rated pickable cast iron covers
4" Plain end connections
8" Plain end connections
Male pipe thread connections
www.striemco.com | Made in the USA | Striem Catalog 8
Oil Reserve™ OCT-275
oil collection tanks
Oil Reserve™ Collection Tanks in
conjunction with oil/sand separators
maximize oil storage capacity and
minimize pump-out frequency. The
collection tank also provides more
accurate oil level monitoring.
OCT-50 OCT-125
Features: above grade or buried installations | easy to carry
HDPE design | TeleGlide™ field adjustable risers | suitable for
exterior installations | install with Striem oil separator
Oil/Sand Oil Collection
Separator Tank
Operating Adjustable Oil Venting Maximum
Water Level Draw-off Arm Spill Line Oil Capacity
Slip
Static Nut
Water Level
Oil/Sand
Separator Oil
Collection
Tank
Cutaway View of
Oil Draw-off Arm
Oil Reserve™ Covers
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
24" 24" 24"
BOLTED BOLTED PICKABLE CAST
COMPOSITE COMPOSITE – TRAFFIC IRON – H20 (optional)
OCT-50 OCT-50 (optional) OCT-50, OCT-125, OCT-275
2,000 lbs. pedestrian load rating OCT-125, OCT-275 16,000 lbs. H20 load rating
16,000 lbs. highway load rating
9 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Specifications
Oil Capacity Pipe Size Rough-in Dimensions (in.) Weight (lbs.)
Cubic Feet Gallons (Plain End SCH.40)
Dry Wet
Striem Inlet Vent Body Vent Inlet Vent/ Adapter Install
Model W AB CD Inlet Adjustability 92 525 with:
130 1,171
L H E (add to B, D & H) 230 2,313 0S-50
0S-75
OCT-50 7 52 2 3 37 28 28 ½ 20 8½ 6½ 22 9 3½ 0S-100
OCT-125 16.7 125 2 3 46 32 38 ½ 28 ½ 10 21 ½ 17 12 6
OCT-275 36.8 275 2 3 68 33 ½ 51 ½ 11 ½ 20 ½ 16 6
40 31
OCT-50 OCT-125 OCT-275
Miscellaneous Options TeleGlide™ Riser Order Guide
*Upgrade to H-20 Desired Riser Height (in.)
Rated Pickable Cast
Striem High Water OCT-50 OCT-125 Risers Needed
Model Anchor Kit Iron Cover OCT-275
OCT-50 Part # Part # 0 - 3½ 0-6 24 Series Adapter
OCT-125 AK1 C24-HP
OCT-275 AK1 C24-HP n/c >3½ - 22 >6 - 24 24 Series
AK1 C24-HP (2) n/c >22 - 37 >24 - 39 Short Riser (SR24)
n/c
n/a >39 - 43 24 Series
Monitoring Packages n/a >43 - 58 Long Riser (LR24)
n/a >58 - 72 24 Series Short +
AVA-3: Single Level AVA-4: Multi-level Short (SR24 + SR24)
Monitoring Package Monitoring Package 24 Series Short +
Remote audio/visual Remote audio/ Long (SR24 + LR24)
alarm panel and visual alarm panel 24 Series Long +
explosion proof and explosion proof Long (LR24 + LR24)
stainless steel multi-level float switch.
float switch. 80%
50%
20%
NOTE 1: When ordered with float switch, add 2" measuring finished cover to centerline of all connections and subtract 2" from available riser height. 10
NOTE 2: OCT-275 has two covers requiring a set of two risers when ordered.
NOTE 3: When upgraded covers are purchased separately, the full price will apply.
www.striemco.com | Made in the USA | Striem Catalog
Solids Interceptors Product Selection
sizing guidelines
For General Applications
Striem recommends that solids interceptors first be sized by pipe size, then by selecting the unit with the
appropriate sediment capacity to provide an acceptable cleaning frequency.
Flow Rates (GPM) by Pipe Size
pipe size per Manning’s Formula*
(nominal)
half pipe flow (design flow) maximum full pipe flow
2 9.67 19.44
3 29.33 58.67
4 62.96 125.77
6 187.74 375.47
preferred flow rate
* ¼" pitch slope based on Manning’s Formula with friction factor N=0.012"
For Lint Applications
Striem recommends the following sizing guidelines.
Step 1 of 2: Select interceptor with appropriate drain line pipe size.
For example, if your primary drain line is 4", choose models with standard 4" connections (models AA-L and AA-XL).
Step 2 of 2: Complete formula, then select interceptor with appropriate
lint capacity based on maintenance interval.
30-Day Professional Maintenance Interval Weekly Do-It-Yourself Maintenance Interval
Gallons Number 30 Gallons Recommended Gallons Number 7 Gallons Recommended
of Lint of Days of Lint Prospector (-S) of Lint of Days of Lint Aardvark
Per Day Machines Per Per Day Machines Per Model
Month Model Week
0.0495 5 30 7.4 PS-15-S 0.0495 6 7 2 AA-S
0.0495 7 30 10.4 PS-25-S 0.0495 14 7 5 AA-M
AA-L
0.0495 12 30 17.8 PS-35-S 0.0495 23 7 8
0.0495 18 30 26.7 PS-50-S 0.0495 29 7 10 AA-XL
0.0495 42 30 62.4 PS-125-S
0.0495 141 30 209.4 PS-275-S
NOTE 1: Average wash cycle time of a commercial laundr y machine = 42 minutes. Average business hours of a commercial laundr y facility =
16 hours. Average lint output per wash of 20-60 lb. commercial laundr y machine = 0.009 gallons (1.14 oz.). Average wash cycles per day of a
commercial laundr y machine = 5.5 cycles. Lint output may var y based on clothes type. For example, towels and linens yield high lint levels while
clothing will yield lower lint levels. Data developed by Striem with assistance from Alliance Laundr y Systems (www.unimac.com) and the Coin
Operated Laundr y Association (www.coinlaundr y.org)
NOTE 2: Periodic maintenance by professional may be required to fully pump down the interceptor.
11 www.striemco.com | Made in the USA | Striem Catalog
HLT/B Series specifications & submittals
under counter solids interceptors formats PDF DOC DWG RFA
available
online
Features: lightweight HDPE body | handles temperatures up to 190º F | 4" threaded and gasket-sealed port | removable type 304
stainless steel basket with 3/32" perforations | for hair and lint applications | used in lieu of fixture P-trap
Specifications
Striem Model Liquid Access Plain End Body Rough-in Dimensions (in.) Outlet Weight
Capacity Location Connections OD Inlet (lbs.)
HLT-1176-1 8 ½
HLT-1176-2 (gal.) Top 1 ½ 8 ½ H A B C D Dry Wet
HLB-1176-1 Top 2 8 ½ 8 ¾
HLB-1176-2 0.5 Bottom 8 ½ 8 ¾ 1 5 ⁄8 7 1 ⁄8 5 3 ⁄8 3 3 ⁄8 5 9
0.5 Bottom 1 ½ 8 ¾
0.5 2 8 ¾ 1 5 ⁄8 7 1 ⁄8 5 3 ⁄8 3 3 ⁄8 5 9
0.5
3 3 ⁄8 5 3 ⁄8 7 1 ⁄8 1 5 ⁄8 5 9
3 3 ⁄8 5 3 ⁄8 7 1 ⁄8 1 5 ⁄8 5 9
HLT-1176 HLB-1176 HLT-1176 Installation HLB-1176 Installation
D D 7" Min.
B B
HLT-1176-1 Shown 7" Min.
H H
C C
A A
OD
OD
USI Series
under counter solids interceptors
Features: lightweight HDPE body | handles temperatures up to 190º F | gasket-sealed cover with hand threaded clamps |
removable HDPE bucket with 3/16" filter screen | for plaster, clay and heavy solids | used in lieu of fixture P-trap
Specifications
Striem Model Liquid Access Plain End Body Rough-in Dimensions (in.) Outlet Weight
Capacity Location Connections Inlet (lbs.)
USI-1180-1
USI-1180-2 (gal.) Top 1 ½ OD CD H A B C D Dry Wet
USI-1184-1 Top 2
USI-1184-2 1.2 Bottom 7 11 11 ¾ 4 3 ⁄8 7 3 ⁄8 8 3 ⁄8 3 3 ⁄8 8 18
1.2 Bottom 1 ½
1.2 2 7 11 11 ¾ 4 3 ⁄8 7 3 ⁄8 8 3 ⁄8 3 3 ⁄8 8 18
1.2
7 11 11 ¾ 3 3 ⁄8 8 3 ⁄8 7 3 ⁄8 4 3 ⁄8 8 18
7 11 11 ¾ 3 3 ⁄8 8 3 ⁄8 7 3 ⁄8 4 3 ⁄8 8 18
USI-1180 USI-1184 USI-1180 Installation USI-1184 Installation
CD OD
B D D 9" Min.
B
A H 9" Min.
OD C H
C
A USI-1180-1 Shown
DRAIN PLUG
CD
www.striemco.com | Made in the USA | Striem Catalog 12
AARDVARK™ SERIES Food
Processing
basket style solids interceptors
Laundry
Facilities
Commercial Art Room
Kitchens Sinks
28
Dog Wash & Barber Shops & SPECIFICATION SHEET : SMALL SOLIDS INTERCEPTOR
Pet Kennels Hair Salons
NOTES:
Innovations 1. 2" SCH. 40 PLAIN END INLET/OUTLET.
2. 16 GALLON LIQUID CAPACITY.
Basket interlocks with inlet to prevent 3. 2 GALLON SOLIDS CAPACITY.
solids from escaping 4. DRY UNIT WEIGHT : 36 LBS.
Uni-Fit™: basket only fits into tank one way 5. COVER LOAD CAPACITY WHEN DIRECTLY
All perforated basket means better flow
through unit BURIED WITH RISER : 2,500 LBS.
6. MAXIMUM CONTINUOUS OPERATING
TEMPERATURE : 190 F.
7. WALL THICKNESS : 3/8".
8. TANK MATERIAL : SEAMLESS HIGH DENSITY
POLYETHYLENE.
9. FOR GRAVITY APLLICATIONS ONLY.
10. FOR ON-THE-FLOOR OR BURIED
APPLICATIONS.
OPTIONS:
SR-16 - ADJUSTABLE RISER.
2M - 2" MPT CONNECTIONS.
3P - 3" PLAIN END CONNECTIONS.
3M - 3" MPT CONNECTIONS.
ENGINEER SPECIFICATION GUIDE CL OF I
STRIEM AARDVARK™ SOLIDS INTERCEPTOR MODEL HIG
SMALL SHALL BE LIFETIME GUARANTEED AND MADE IN 14-1
USA OF SEAMLESS, ROTATIONALLY-MOLDED HIGH
DENSITY POLYETHYLENE WITH MINIMUM 3/8" UNIFORM CL OF I
WALL THICKNESS. INTERCEPTOR SHALL BE FURNISHED HIG
FOR ABOVE OR BELOW-GRADE INSTALLATION.
INTERCEPTOR SHALL BE FURNISHED WITH FILTER
BASKET AND CONNECTION FOR EXTENDING HANDLE FOR
DEEP BURIALS. COVER SHALL PROVIDE WATER/GAS-
TIGHT SEAL AND HAVE A MINIMUM 450 LBS LOAD
CAPACITY.
Optional low outlet Signature of Approval:
Moveable sewer gas trap between Company:
high or low outlet Date of Approval:
Specifying Engineer:
Field-adjustable basket handle for Engineering Firm:
deeper burials
Cover options 28-1/2"
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
indoor covers outdoor covers
16" 24" 24" 24" THE INFORMATION CONT
ANY REPRODUCTION IN PART O
BOLTED BOLTED BOLTED PICKABLE CAST
POLYPROPYLENE COMPOSITE COMPOSITE – TRAFFIC IRON – H20 (optional)
AA-S AA-M AA-L (optional) AA-L
AA-L AA-XL AA-XL
13
www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
46" 46"
A 37" 37" A A A
A
28" A A 32"
32"
28"
37" 46" A 25" 25" AA 33" 33"
46"
A 19" A 25" A A
A A
37" 25"
19"
A
A A A A
28" A
8" 32"
DESIRED D3RE2IPS"TEHR GUIDE RISER
REQUIRED
0" - 2" N/A
> 2 1/2" - 16" (1) SR - 16
> 16" N/A
AA-S AA-M AA-L AA-XL
33" CL OF INLET AND CL OHFIGINH46LO"EUT2T4A-L1NE/D2T" 24-1/2"
SPECIFICATIONS (PS-125-B) HIGH OUTLET
1. 4" inlet/outlets Sch. 40. (No-Hub)
25" 33" 2. Liquid capacity: 125 Gallons
SPECIFICATIONS (PS-35-B) 25" 3. Basket capacity: 10 Gallons
C45L..OHFcUHIGoinIgmNHiht pLwwOoEaeUsTyiigTteArhLatNcEtweoDTdv/s,etbrdso.,lct1eo6dv,e,0rg0sa0C:Ls1l/bwO4Hs8aFIlGtolebIaNHrsdt.Li.O1gE6hUT"tTACLNOEDTVER
1. 3" inlet/outlets Sch. 40. (No-Hub) A A33" 37" 10" Adjuasdtaapb1tl0ee"r
2. Liquid capacity: 35 Gallons Adjustable 16" COVER
3. Basket capacity: 5 Gallons A A NOTES adapter A 25"
4. Unit weight w/std. covers: 86 lbs. 25" 6. Maximum operating temperature 190 F continuous. A 25" 15"
A A1. General purpose solids interceptor.
A5. 2,000 lb. load rated, bolted, gas/water tight A 615432S......PEcB2ULM4Co,i"anqa0ImiAsFiux0ntkIipi0lwmdCeeotetlAucsb/oicamig.TtauephlIoptOaotlcaeacpwNodtciestv/Siystrr2eySa:at5(r2d:t5tcPs"ie.85nh2.Sdc"g.G,G-o45tbvaea00eolml.l-lorloBt(spneANn):esdso1r,-a046352gHt9.....auusrlbbe/fDFDdU3aC)wose/d1oo.noer8aej9rivsup"tntp0egeisrgotseorhrrtuntaaFrpitpcpeuivbebglkcpdsiairtuhloeylicsitnrmtenyeiedfaad.tomaairlrnArairmwdneouidpnetnilwoetdreaphteunisgttfasshiasbooels.l.nuoonhuac2itwailrpgtepe5-lrsh.ipi"rnnailfsdiutpcaeelapadlrnllt(aaliissocopci)awntctytaesesiorrpseocnfosolnsealytrl.ayolesu.r1ottapha4naynt-col1vkeea/6n4il"e"ao4bwfl-1ea10l/lf"4sAo."r 4-1/4" 32" A
composite covers. 15"
6. Maximum operating temperatu1r9e"190 F continuous. A
19" A 14-1/4"
28" 10"
NOTES
1. General purpose solids int1e9rc"eptor.
2. For gravity drainage applications only.
Do not use for pressure applications.
3. 3/8" thick seamless high density polyethylene walls. through doorways and down stairwells.
4. Unit supplied with built-in adapter for up to 3-1/2" of 7. Internal components are removable for easy
adjustability. Additional riser(s) are also available for NOTES maintenance. 4" CL OPTIONAL 4" CL OPTIONAL 6" CL OPTIONAL 6" CL OPTIONAL
deeper burial depth. 1. General purpose solids inter8c.eptFoor.r on-the-floor or buried applications. LOW OUTLET LOW OUTLET LOW OUTLET LOW OUTLET
5. Cover placement allows full access to tank 2. For gravity drainage applications only.
for proper maintenance. Do not use for pressure applications.
6. Internal components are removable for easy 3. 3/8" tshuicpkplsieedamwiltehssbuhiilgt-hindaednaspittyerpfoolyr eutphytole3n-e1Tw/2Oa"lPolsf. ISOMETRIC VIEW AA-S TOP VAIEAW-S TECHNICAL BENEFITS / INNOVATIONS TOP VAIEAW-M AA-M
TOP VIEW 4. Unit VIEW • NO "BACKFLOW" FROM BASKET.
maintenance.
7. For on-the-floor or buried applications. adjustability. Additional riser(s) are also available for • BEINANTSHEKCARLENLOHTCOFIE-GCIADKNHLILFNLOELGUPTOETBWALRANEFTSDT.HKREOT.UGTHifeo-rdaonwcnhpoor iknitt
deeper burial depth. full access to tank Deep structural • 24-1/2" DreeinefpOCorLsUctOiTrnuSLgcEEtcuTDoralDuTlmIOPnPTsUBE
COLU56OT..SLEEfIConTDorteDvpTrerIOnPoraPpTpleUlcaroBcmmeEmapionentneetnnaatlslnocawerse. ENGINEER SPECIFICATION GUIDE
SENtriGeImNEPEroRsSpePcEtCoCrLIF™IOCsFAoTIliNIdOsLNEinTGteUArcINDeEDptor model PS-35-B shall model PS-125-B shall Tie-down point reinforcing colum• ns HIGH / LOWCLOOUFTILNELTEST. AND CL OF INLET AND
be lifetime guaranteHedIGaHndOMUaTdLeEinT USA of seamless, remSotrviaebmlePfroorsepaescytor™ solids interceptor for anchor kit OPTIONAL VEHNITG.H OUTLET HIGH OUISTLO2E4MT-1E/2T" RIC
OPTIONAL TRA1P2.-1/2"
16" COVER maintenance. be lifetime guaranteed and Made in USA of seamless, • VIEW 24-1/2"
SWAP CAP AND DIPTUB
rotationally-molded High Density Polyethylene with minimum 7bSrE3o.e/Nt8traiGl"eitFfiuImeISoNoFntnWriEiPmUafoEoArleSnlIorRyNPm8-Isg-Nt2VSm-phCCu3"LwGePEeao/AWc4a-EORrlHfPLdat"llColATFoIOeCnGLtrAIoTdhtF™IWeNHrEiOIHcHeCoLDRkOsFdIiArEgnGoUDUSbTTahIelNHiTunEIITdsAOPD1rLLdssLAiON0TNEee.EE1LiM"DUdnnIUTTT0nGtsaBTae"tUiAedtEprLyrceIrba1mwNpDEcoePbu/leiiDi2ETtitpnnorcaohp"itiaavtloUmtyiufoetloirsieSlnurotn.moetimAnsahfCrrohsolylborbo1y.adlmeefav-6lelmnelss,olwb0eekroPwe0eaaslwSd-0tlmhfglieu-aattlr5lhbdrhnealnl0siddsmcHpi-sseBklrcoiCih,2ognnLoiaes4nvheinmdhd-OissHd1nDatsuceaf/eFI2leo2.amGllc4l"wnrIpaItnNH-isaatot1iieocttLn/eyOri2nEtc1rfy".PU/oeT0gIropnT"alAettysLoexeN-rErtttciesDhCgTeLnhyhpdalOteHtilosnlnFIergbGeaseIhNHwlhOCaf1aaLiutOnL0UnlhErldOn-dUTTb1mlieSsLTeh/A2ihISEEanLfFfo"eNWTu2DviEmrdUer"DTDAndTuSWfaiPoIeOsmIPNArehPCTCpLTGeUAdEOBHPLROFEI2AGSW4INNHE-D1CAOLLO/ELDU2OUHT"IT1PTFIL0AGTLE-INU1ENHT/DBT12LOE0"E-UT12T/A42L-"NE1D/T2" ISOMETRIC VIEW • IF USING LOW OUTLET
3/8" uniform wall thickness. Interceptor shall be furnished for 24-1/2" CLOSED TOP
above or below-grade installation.4I-n1t/e4r"ceptor shall be furnished 24-1/2" OUTLET DIPTUBE
with filter basket and connection for extending handle for deep 2" WATER SEAL
12-1/2" 12-1/2"
burials. Cover shall provide water/gas-tight seal and have a
minimum 2,000 lbs load capacity SWAP CAP AND DIPTUBE
1CL4-O1/F4"INLET AND
INLET AND HIG1H61"O0C"UOTVLEERT IF USING LOW OUTLET
GH OUTLET
16" COVER 38-1/2"
OPTIONS: above or below-gra2d5e" installation. Interceptor shall be furnished OPTIONS: 2" WATER SEAL
• 4-12TM/"e4alole"erg4pli"dipePelfatiehinlrdeeaandddjcuposipntaenbeolecrtirmoisnaeslrespf4oip-re1e/tx4htr"eenaddincgocnonveecrtsiotnosgrade with filter basket and connection for extending handle for deep • MTealleegplidipeeftiehlrdeaaddjcuos2nta8nb-e1lec/t2iro"isnesrs for extending covers to grade 38-1/26" " 38-1/2" 23-3/4"
• FILTER BASKET mbuinriiamlsuL4.mO"CCWo2Lv,0eOO0rUP0sTThlbLaIOsEllNlTpo2Arao5Ldv"icd1ae5p"wacaitteyr/gas-tight seal and have2a5" • 26" INVERT
• STATIC 2•••8-1/HH62"2i"gPOhlarwianateteednrdpaIi1nNpc3kciVp-ahE1ebo/R4lrceT"okcnitan(sestec2ittri8ooo-nnf1s2c/21)o(N"8v"eor-Hub)
WATER LINE
15-3/4" 26"
1/4" 14-1/4" 2-7/8" OPTIONAL 15" INVERT
10" 10" SECTION "A-A" LOW INVERT 15"
18" 18"
OPTIONS:
• Teleglide field adjustable risers for extending covers tSoTgArTaIdCe
• Male pipe thread connections 6" CL OPTIONAL STATIC 10" CL OPTIONAL
• 3" Plain end pipe orFmILaTlEeRpiBpAeSthKrEeTad connectioWnsATER LINE LOW OUTLET STATIC 6-1/2" CL OPTIONAL FILTER BASKET WATER LINE LOW OUTLET
WATER LINE LOW OUTLET
4" CL OPTIONAL 4" LCLOWOPOTUIOT••• NLEAHHHTLi2igg0hhwrwaataeytderarptaiecndkcabhboolelrtekcdita(csstoeimrtoponof cs2oi)tevecrover 6" LCLOWOPOTUIOTNLEA4LTL-O1W/4"INOVPETRIOTNAL 6" FILTER BASKET CL OPTIONAL7L-O3W/4"INOVPETR1IO0TN" ACLL OPTION
LOW OUTLET CL OPTIONAL
LOW O6U-1T/L2E" TCL OPTIONAL 6-1/2" CL OPTIONAL4-1/4" OPTIONAL
AA-S LOW OUTLET LOW OUTLETLOW INVERT SECTION "A-A" 10" LOW OUTLET LOW OUT
SECTION "A-A"
AA-S AA-M AA-M AA-L AA-L AA-XL AA-XLSECTION "A-A"
Striem Striem
3 100 Brinkerhoff 3100 Brinkerhoff
Striem Kansas City, KS 66115 Kansas City, KS 661
CL OF INLET AND C 3 100 Brinkerhoff
HIGH OUTLET L OF IN2L4E-1T/2A" ND 24-1/2" Kansas City, KS 66115 wFTwaexwl::.9s9t11r3i3e--2m229c21o--K10.ac540no350s17ma0s0SCBtirrtiiyne,kmKewSrFThw6aeo6xwlf:1f:.91s9t151r3i3e--2m229c21o--10.c540o507m
HIGH OUTLET Tel: 913-222-1500
3100SBtrriinekmerhoffPROPRIETARY AND CONFIDENTIAL Fax: 913-291-0457
PROPRIETARY AND CONFIDENTIAL www.striemco.com
STANDARD SPEC S STANDARD SPEC S STANDARD SPEC S STANDARD SPEC SINLET AND Made in the U.SFT.aeAxl:: 991133--222921--M1054a05d07e in the U.S.A
GH OUTLET
PROPRIETARY AND CONFIDENTIAL Kansas City, KS 66115THE INFORMATION CONTAINED IN THIS DRAWING ISTTHHEEINSFOOLREMPARTOIOPNERCTOYNOTFAISNTERDIEINM,TLHLISC.DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC. PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHAONUYTRTEHPERWODRUITCTTEINONPEINRMPAISRSTIOONROAFS SATWRIHEOML,ELLWCI.TIHSOUT THE WRITTEN PERMISSION OF STRIEM, LLC. IS
12-1/2" FTaexl:: 991133--222921--10540507PROHIBITED. PROHIBITED. Made in the U.S.ATHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC.
CL OF INL2E4T-1A/2N" D 24-1/2" 12-1/2"ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF STRIEM, LLC. IS PROPRIETARY AND CONFIDENTIAL ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF STRIEM, LLC. IS www.striemco.com
PROPRIETARYHANIDGCHONOFIDUENTTLIAEL T PROHIBITED. PROHIBITED.
www.striemco.comTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC.
CONNECTIONS: 2” SCH. 40 PLAIN END INLET/OUTLETS CONNECTIONS: 3” SCH. 40 PLAIN END INLET/OUTLETS CONNECTIONS: 4” SCH. 40 PLAIN END INLET/OUTLETS CONNECTIONS: 4” SCH. 40 PLAIN END INLET/OUTLETSTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC.
ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF STRIEM, LLC. IS
PROHIBITED.
ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF STRIEM, LLC. IS Made in the U.S.A
PROHIBITED.
Made in the U.S.A
LSIOQLUIDIDSCCAAPPAACCIITTYY:: 2 GAL. HLIGOWH::145GGAALL. . LSIOQLUIDIDSCCAAPPAACCIITTYY:: 6 GAL. HLOIGWH::1325GGAALL.. SLIOQLUIDIDSCCAAPPAACCIITTYY:: 8 GAL. HLOIGWH::1542GGAALL.. LSIOQLUIDIDSCCAAPPAACCIITTYY:: 10 GAL. HLIGOWH::13205GGAALL. .10-1/2"
10-1/2"
38-1/2" 38-1/2"
" 2W8-E1/I2G" HT: 42 LBS. WEIG2H6T" : 83 LBS. 26" WEIGHT: 105 LBS. WEIGHT: 145 LBS.
18" INSTALL1A8"TION: ABOVE OR BELOW GRADE INSTALLATION: ABOVE OR BELOW GRADE INSTALLATION: ABOVE OR BELOW GRADE INSTALLATION: ABOVE OR BELOW GRADE
6-1/2" CL OPTIONAL 6-1/2" CL OPTIONAL 10" CL OPTIONAL 10" CL OPTIONAL
LOW OUTLET LOW OUTLET LOW OUTLET LOW OUTLET
AA-L AA-L AA-XL AA-XL
Striem Striem RISER ORDER GUIDE
3100 Brinkerhoff
Kansas City, KS 66115 REQUIRED RISER
3 100 Brinkerhoff DESIRED DEPTH
Tel: 913-222-1500 KaTnesla: s91C3it-y2R,2K2I-S1S656E010R15 ORDER GUIDE SR24 LR24
PROPRIETARY AND CONFIDENTIAL RISER ORDER GUIwFDwaExw:.s9t1ri3e-m29c1o-0.c4o57m Fax: 913-291-0457 REQUIRED RISER 0" - 6" INCLUDED
TAINED IN THIS DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC. REQUMaIRdeEiDn tRheISUE.SR.A wDwEwS.IsRtriEeDmcDoE.cPoTmH
RISER ORDER GUIDEOR DESIRED DEPTH > 6" - 24" 10
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SPTRROIEPMR, LILECT. AISRY AND CONFIDENTIAL Made in the U.S.A
PROHIBITED.
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF STRIEM, LLC. SR24 LR24 SR24 LR24
ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF STRIEM, LLC. IS
DESIREPRDOHIBDITEED. PTH REQUIRED RISER > 24" – 39" 01
INCLUDED 0" - 3-1/2" INCLUDED
0" - 2" N/A 0" - 3-1/2" > 39" – 43" 20
> 2-1/2" - 16" (1) SR - 16
> 3-1/2" - 22" 10 > 3-1/2" - 22" 10 > 43" – 58" 11
> 16" N/A > 22" – 37" 01
> 22" – 37" 01 > 58" – 72" 02
www.striemco.com | Made in the USA | Striem Catalog 14
Prospector™ Series
screen style solids interceptors
Prospector™ Screen-Style PS-35-S PS-275-S PS-125-S
Solids Interceptors provide PS-15-S PS-25-S PS-50-S
a removable filter screen to
allow for professional pumping
maintenance.
Features: above grade or buried PS-125-S Shown
installations | non-corrosive polypropylene
filter | easy to carry HDPE design | 6
models with sediment capacities from
8 gallons up to 210 gallons | removable
filter screen | TeleGlide™ field adjustable
risers | models PS-50-S through PS-275-S
suitable for exterior installations
Prospector™ Covers
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
indoor covers outdoor covers
16" 24" 24" 24"
BOLTED BOLTED BOLTED PICKABLE CAST
POLYPROPYLENE COMPOSITE COMPOSITE – TRAFFIC IRON – H20 (optional)
PS-15-S, PS-25-S PS-35-S, PS-50-S PS-50-S (optional), PS-50-S, PS-125-S, PS-275-S
2,000 lbs. pedestrian load rating 2,000 lbs. pedestrian load rating PS-125-S, PS-275-S 16,000 lbs. H20 load rating
16,000 lbs. highway load rating
15 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Specifications
Capacity and Rating Pipe Sizes Rough-in Dimensions (in.) Weight (lbs.)
Striem Total Solids *No. of Plain End SCH.40 Optional Body Inlet/Outlet Adapter
Model Male
Liquid Capacity Washing Thread Adjustability Dry Wet
(gal.) (gal.) Machines Standard Optional (no (add to B & H)
Plain L W H A B
charge)
PS-15-S 16 8 5 2 3 2, 3 25 19 14 ¼ 10 4 ¼ n/a 29 162
PS-25-S 22 11 n/a 35 219
7 3 2 2, 3 27 21 15 10 ¾ 4 ¼
PS-35-S 35 17.5 12 3 2, 4 2, 3, 4 33 25 25 15 10 3 ½ 83 375
PS-50-S 52 26 18 4 2, 3 2, 3, 4 37 28 28 ½ 18 10 ½ 3 ½ 106 550
PS-125-S 125 62.5 42 4 6 4 46 32 38 ½ 26 12 ½ 6 140 1,183
PS-275-S 275 210 141 4 6 4 68 33 ½ 51 ½ 38 13 ½ 6 270 2,564
* Based on 30-day maintenance interval.
PS-15-S PS-25-S PS-35-S PS-50-S PS-125-S PS-275-S
Miscellaneous Options TeleGlide™ Riser Order Guide
High Water *Upgrade to *Upgrade to Desired Riser Height (in.)
Anchor Kit Highway H-20 Rated
Striem Pickable Cast PS-15-S PS-35-S PS-125-S Risers Needed
Model Part # Rated Bolted Iron Cover PS-25-S PS-50-S PS-275-S
n/a Composite Cover 16 Series
PS-15-S n/a Riser (SR-16)
PS-25-S n/a Part # Price Part # Price >2 1 ⁄8 - 16 n/a n/a 24 Series Adapter
PS-35-S AK1 n/a 0 - 3½ 0-6
PS-50-S AK1 n/a n/a 24 Series
PS-125-S AK1 Short Riser (SR24)
PS-275-S n/a n/a n/a >3½ - 22 >6 - 24
24 Series
n/a n/a Long Riser (LR24)
24 Series Short +
C24-H n/c C24-HP n/c n/a >22 - 37 >24 - 39 Short (SR24 + SR24)
24 Series Short +
included C24-HP n/c n/a n/a >39 - 43 Long (SR24 + LR24)
24 Series Long +
included C24-HP(2) n/c Long (LR24 + LR24)
* When ordered with solids interceptor. n/a n/a >43 - 58
n/a n/a >58 - 72
Polypropylene Screen Filter Options (actual sizes shown)
Buttons, Change, Gravel Medium – 0.1" x 0.08" opening Precious Metals, Fine Sand
Coarse – 0.3" x 0.27" opening Fine – 0.03" x 0.025" opening
–C –M –F
NOTE 1: Select appropriate screen filter suffix in step 3 to complete model number. 16
NOTE 2: Subtract 1" from adapter and riser range when PS-35-S is ordered with 4" connections.
NOTE 3: PS-275-S has two covers requiring a set of two risers when ordered.
www.striemco.com | Made in the USA | Striem Catalog
Settler™ Series CB-275-S CB-125-G
CB-125-S
catch basins
CB-50-S CB-50-G
Settler™ Catch Basins allow sand and
sediment to collect from the bottom up and
may drain either through a drain line (-S
models) or directly through a top inlet grate (-G
models). An optional removable filter basket
may be ordered with –G models to allow for
intermittent DIY (do-it-yourself) maintenance
and to catch valuables that need to
be retrieved.
Features: for buried installations | easy to carry HDPE
design | 5 models from 50 to 275 gallons | TeleGlide™
field adjustable riser system | suitable for exterior
installations
Cutaway of CB-275-S Shown
Settler™ Covers
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
outdoor covers and grate
24" 24" 28"
BOLTED PICKABLE CAST IRON PICKABLE
COMPOSITE – TRAFFIC – H20 (optional) GRATE – H20
CB-50-S, CB-125-S, CB-275-S CB-50-S, CB-125-S, CB-275-S CB-50-G, CB-125-G
16,000 lbs. highway load rating 16,000 lbs. H20 load rating 16,000 lbs. H20 load rating
17 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Specifications
Capacity Pipe Sizes Rough-in Dimensions (in.) Weight (lbs.)
Striem Total Optional Plain End SCH.40 Optional Body Inlet/Outlet Adapter Dry Wet
Model Liquid Basket Standard Optional Male Thread W AB Adjustability
(gal.) Capacity (no charge) (add to B & H)
(gal.) L H
CB-50-S 52 n/a 4 2, 3 2, 3, 4 37 28 28 ½ 18 10 ½ 3 ½ 86 520
CB-50-G 52 7
CB-125-S 125 n/a 4 2, 3 2, 3, 4 37 28 30 1 ⁄8 18 12 1 ⁄8 3 ½ 187 621
CB-125-G 125 7
CB-275-S 275 n/a 4 6 4 46 32 38 ½ 26 12 ½ 6 123 1,166
4 6 4 46 32 40 1 ⁄8 26 14 1 ⁄8 6 213 1,256
4 6 4 68 33 ½ 51 ½ 38 13 ½ 6 218 2,532
* Smaller sizes available upon request.
CB-50-S CB-50-G CB-125-S CB-125-G CB-275-S
Miscellaneous Options TeleGlide™ Riser Order Guide
Optional High Water *Upgrade to Desired Riser Height (in.)
Basket Anchor Kit H-20 Rated
Striem Pickable Cast CB-50-S CB-125-S, CB-125-G Risers Needed
Model Iron Cover CB-50-G CB-275-S
Part # Part # Part # 0 - 3½ 0-6 24 Series Adapter
CB-50-S n/a AK1 C24-HP 24 Series
n/a Short Riser (SR24)
CB-50-G BCB-7 AK1 >3½ - 22 >6 - 24
C24-HP >22 - 37 >24 - 39 24 Series
CB-125-S n/a AK1 n/a >39 - 43 Long Riser (LR24)
n/a >43 - 58 24 Series Short +
CB-125-G BCB-7 AK1 C24-HP(2) n/a >58 - 72 Short (SR24 + SR24)
n/a 24 Series Short +
CB-275-S n/a AK1 Long (SR24 + LR24)
24 Series Long +
Long (LR24 + LR24)
* When ordered with catch basin.
BCB-7
Optional 7 gal. sediment
basket with coarse filter
(0.3" x 0.27" openings) for
initial separation of large
solids. (weighs 10 lbs.).
Must be ordered with
catch basin.
NOTE: CB-275-S has two covers requiring a set of two risers when ordered.
www.striemco.com | Made in the USA | Striem Catalog 18
Chemical Waste Tanks Product Selection
sizing guidelines
Did You Know? EPA Guidelines for Acceptable pH Levels
Plumbing and pretreatment codes
require treatment of acidic waste, 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0
but make no mention of caustic waste.
Caustic waste can be just as harmful ACID 7.0 NEUTRAL ALKALINE
and must be considered when choosing
the neutralization approach. Stomach Acid Limes Apples Beer Milk Egg Whites Bleach Drain Cleaner
Step 1 of 6: Determine Characteristics of the Waste Stream
a) If acidic – proceed to step 2. b) If caustic or caustic and acidic, reagent injection system needed.
Step 2 of 6: Choose Neutralization System Type
Continuous (go to step 3) or Batch (contact Striem)
Use • Flow is relatively constant and not characterized by large surges. Use • Flow is discharged in large batches or there are large
When • Influent chemistry is relatively constant and not characterized by When fluctuations in flow.
large swings in pH. • Influent chemistry is characterized by large swings in pH.
• Effluent chemistry is not critical, such as the first stage in a • Effluent makeup is critical and pH must be kept within
multi-stage process. specific parameters.
Examples High school, college, and professional labs Examples Manufacturing, pharmaceutical, and food processing
Step 3 of 6: Determine Size of Tank
For all labs, use "Sizing by Sinks" table below to determine tank size to provide adequate residence time for acid neutralization via limestone treatment.
Residence times vary significantly based on strength of acid. For more information on required contact time, see "Contact Time" table below.
Sizing by Sinks Contact Time For Limestone Neutralization of Acids*
Per ASPE Plumbing Engineering Design Handbook Volume 3
Number of Tank Size Number of Tank Size 150 Tank Size
Lab Sinks (Gal.) Lab Sinks (Gal.) 175 (Gal.)
200
2 5 30 108 300 500
4 15 40 150 500 550
8 30 50 175 600 650
16 55 60 200 1,200
22 75 75 275 2,000
27 90 110 360 3,000
NOTE: Table assumes a “worst case scenario” influent pH of 2 and provides
3 hours residence time at a flow rate of 1 GPH per fixture. See "Contact
Time" table for appropriate limestone contact time.
*Data provided via third party test requested by Striem.
Step 4 of 6: Consider Solids Pretreatment
Most lab waste contains solids that can clog the acid waste drain system. It is recommended that a solids interceptor be installed in front of
centralized neutralization tanks. See the Prospector™ Series on p. 13-16 for more information.
Step 5 of 6: Determine Tank Material
Striem offers neutralization tanks in both polyethylene and polypropylene. While polyethylene is adequate for most projects, it’s important to
consider the chemical resistances of polyethylene and polypropylene.
Step 6 of 6: Consider pH Monitoring
All acid waste streams should be monitored. The monitor acts as both an alarm in the event of system failure and to indicate when the
neutralization media needs to be replaced. See Striem’s Command Center™ on p. 25-26.
19 www.striemco.com | Made in the USA | Striem Catalog
Lab Rat™ Series specifications & submittals
under counter neutralization tanks formats PDF DOC DWG RFA
available
online
The Lab Rat™ Series of under-counter neutralization tanks for LB-5 LB-2
school labs is the most versatile design in the industry with 5-Gallon 2-Gallon
standard top or side inlet connections, hand-threaded cover
and adaptability for 1½" or 2" drain lines.
Features: 2 and 5 gallons | for under counter sink installations | gasketed top
with captive hand-thread hardware | easy to carry HDPE design | combination
1½" or 2" FPT connections standard | built-in top and side inlet options |
optional top vent connection (LB-5 only) | internal sewer gas seal
Specifications
Rough-in Dimensions (in.) Pipe Connections Weight (lbs.)
Striem Liquid Sizing By Body Side Inlet/Outlet Top Inlet Standard FPT Outlet Optional Dry Wet
Model Capacity Number Connections Location Top Vent Wet with
Connection 6
(gal.) of Sinks per ANSI 11 Limestone
B1.20.1
L WH A B C D 23 28
LB-2 2 1 1 ½ or 2 Top or Side n/a 58 80
LB-5 5.3 2 9 9 10 1 ⁄8 7 2 7 2
14 14 12 5 ⁄8 9 2 ½ 11 ½ 2 ½ 1 ½ or 2 Top or Side included
LB-2 LB-5
Side View Top View Side View Top View
Limestone Application Specific Details
Striem Model Load (lbs.) Part # LB-2 Elevated LB-5 Elevated
LB-2 25 LS-25
LB-5 50
LS-50
Optional
Vent
When loading Lab 4" Plain End 4" Plain End
Rat™ Series tanks with Pipe by Others Pipe by Others
limestone, use Striem Cut to Size Cut to Size
limestone chips 2 - 3"
in size with a calcium LB-2 with Limestone Serving LB-5 with Limestone Serving
carbonate content (CACO3) Condensate Line Condensate Line
of 90% or greater. When
limestone is depleted High Efficiency High Efficiency
contact a waste specialist Water Heater or Water Heater or
to evacuate basins. Condensing Boiler Condensing Boiler
Condensate Line Condensate Line
Up to 2 GPH Up to 6 GPH
www.striemco.com | Made in the USA | Striem Catalog 20
Lab Basin™ Series
neutralization tanks
Lab Basin™ Neutralization Tanks LB-35 LB-275 LB-125
are designed for above or below LB-15 LB-25 LB-50
grade installation, providing an
excellent value for the most
common industry neutralization
tanks sizes from 15 gallons to
275 gallons.
Features: 15 through 275 gal. | easy to Cutaway of LB-275 Shown
carry HDPE design | above or below grade
installations | TeleGlide™ field adjustable
riser system | models LB-50 through LB-
275 suitable for exterior installations
Lab Basin™ Covers
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
indoor covers outdoor covers
16" 24" 24"
BOLTED BOLTED BOLTED
POLYPROPYLENE COMPOSITE COMPOSITE – TRAFFIC
LB-15, LB-25 LB-35, LB-50 LB-50, LB-125, LB-275
2,000 lbs. pedestrian load rating 2,000 lbs. pedestrian load rating 16,000 lbs. highway load rating
21 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Made To Order – Submittal Required
Specifications
Recommended Rough-in Dimensions (in.) Weight (lbs.)
Pipe Size
Sizing By Limestone Liquid
Striem Number Required Holding Inlet & Body Inlet/Outlet Vent Adapter
Model of Sinks (lbs.) Gallons Outlet W AB CD Adjustability
Vent (add to Dry Wet
L H E
H & B)
LB-15 4 200 15 2 2 25 19 14 ¼ 10 4 ¼ 11 ½ 2 ¼ 5 ½ n/a 28 166
LB-25 3 n/a 31 220
LB-35 6 275 22 3 2 27 21 15 10 ¾ 4 ¼ 11 ½ 3 ½ 6 ¼ 3 ½ 77 369
LB-50 4 3 ½ 92 525
LB-125 9 450 35 4 2 33 25 25 15 10 17 8 7 ½ 6 130 1,171
LB-275 4 6 230 2,313
15 650 52 2 37 28 28 ½ 18 10 ½ 20 8 ½ 9
35 1,550 125 2 46 32 38 ½ 26 12 ½ 28 10 ½ 12
75 3,150 275 2 68 33 ½ 51 ½ 38 13 ½ 40 11 ½ 16
LB-15 LB-25 LB-35 LB-50 LB-125 LB-275
Miscellaneous Options: TeleGlide™ Riser Order Guide
Miscellaneous Options Desired Riser Height (in.)
Striem High Water Limestone *Upgrade to LB-15 LB-35 LB-125 Risers Needed
Model Anchor Kit Highway Rated Bolted LB-25 LB-50 LB-275 16 Series
Part #
LB-15 Part # LS-50 (4) Composite Cover Riser (SR-16)
LB-25 n/a LS-50 (6)
LB-35 n/a LS-50 (9) Part # Price >2 1 ⁄8 - 16 n/a n/a
LB-50 n/a LS-50 (13)
LB-125 AK1 LS-50 (31) n/a n/a 0 - 3½ 0-6 24 Series Adapter
LB-275 AK1 LS-50 (63)
AK1 n/a
n/a n/a >3½ - 22 >6 - 24 24 Series
Short Riser (SR24)
C24-H n/c
included n/a >22 - 37 >24 - 39 24 Series
Long Riser (LR24)
included
24 Series Short +
* When ordered with neutralization tank. n/a n/a >39 - 43 Short (SR24 + SR24)
n/a n/a >43 - 58 24 Series Short +
Long (SR24 + LR24)
n/a n/a >58 - 72 24 Series Long +
Long (LR24 + LR24)
For monitoring package see Command
Center™ on pages 25-26
NOTE 1: Subtract 1" from adapter and riser range when LB-35 is ordered with 4" connections. 22
NOTE 2: LB-275 has two covers requiring a set of two TeleGlide™ risers when ordered.
www.striemco.com | Made in the USA | Striem Catalog
NT Series Better Below
Grade Value
neutralization tanks See Lab Basin™
Models on
p. 21-22
Specifications
Capacity Recommended Rough-in Dimensions (in.) Weight (lbs.)
(gal.) Pipe Size
Sizing In/Out Vent Adapter
Striem by Body C/L to C/L to In/Out Adjust- Above Below Lab Basin™
Model No. of Bottom Bottom C/L to ability Grade Grade Equivalent
Sinks Liquid Inlet / of Tank of Tank Cover (add to
Holding Outlet Vent HB & B) LB-35
C* LB-50
ID OD HA HB A B 3 ½" Dry Dry LB-125
6" LB-275
NT-30 8 30 3 2 22 28 24 ½ 33 20 21 13 6" 32 66 LB-275
6" LB-275
NT-55 16 55 3 2 24 30 36 ½ 43 ¾ 30 32 13 ¾ 6" 43 116 LB-275 (2 in series)
6" LB-275 (3 in series)
NT-100 32 117 4 2 31 37 48 5 ⁄8 56 ½ 38 40 17 ¾ 6" 87 178
6" —
NT-150 41 154 4 2 36 40 48 ½ 55 ¾ 38 40 17 ¾ 6" 86 212 —
6" —
NT-200 63 210 4 2 42 48 48 ½ 56 ½ 38 40 17 ¾ 6" 142 250
NT-275 75 275 4 2 48 52 48 ½ 56 ½ 38 40 17 ¾ 132 310
NT-350 107 350 4 2 52 58 48 ½ 56 ½ 41 43 14 ¾ 130 372
NT-500 150 500 4 2 48 54 84 ½ 92 ½ 70 76 21 ¾ n/a 425
NT-750 230 750 6 4 67 81 n/a 77 59 / 57 n/a 19½ / 21½ n/a 1200
NT-1000 300 1000 6 4 76 90 n/a 77 59 / 57 n/a 16¼ / 18¼ n/a 1400
NT-1500 500 1500 6 4 106 120 n/a 77 59 / 57 n/a 16 / 18 n/a 1700
* Inlet/outlet centerline to cover dimensions listed are for below grade (-B) models only. NT-30 through NT-500
Above Grade Below Grade
NT-750 Side View NT-1000 Side View NT-1500 Side View
23 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Made To Order – Submittal Required
Model Numbers and Limestone Requirements
Polyethylene Add for Limestone
Above Grade Below Grade Part # Load
(lbs.)
Striem Model Striem Model
NT-30-A-PE NT-30-B-PE LS-50 (8) 400
NT-55-A-PE NT-55-B-PE LS-50 (14) 700
NT-100-A-PE NT-100-B-PE LS-50 (29) 1,450
NT-150-A-PE NT-150-B-PE LS-50 (38) 1,900
NT-200-A-PE NT-200-B-PE LS-50 (52) 2,600
NT-275-A-PE NT-275-B-PE LS-50 (66) 3,300
NT-350-A-PE NT-350-B-PE LS-50 (86) 4,300
n/a NT-500-B-PE LS-50 (130) 6,500
n/a LS-50 (196) 9,800
n/a NT-750 LS-50 (260) 13,000
n/a NT-1000 LS-50 (390) 19,500
NT-1500
Polypropylene tanks available upon request
TeleGlide™ Riser Order Guide
Desired Riser Height (in.)
NT-30 all other Risers Needed FOR
NT models MONITORING
PACKAGE see
0 - 3½ 0-6 24 Series Adapter Command Center™
>3½ - 22 >6 - 24 on pages 25-26
>22 - 37 >24 - 39 24 Series
>39 - 43 Short Riser (SR24)
n/a >43 - 58
n/a >58 - 72 24 Series
n/a Long Riser (LR24)
24 Series Short +
Short (SR24 + SR24)
24 Series Short +
Long (SR24 + LR24)
24 Series Long +
Long (LR24 + LR24)
NT Tank Covers
Covers are provided with water/air tight gasket seal and are designed to fit tightly into a key-fit frame.
indoor covers outdoor covers
15" 24"
THREADED BOLTED
POLYPROPYLENE COMPOSITE – TRAFFIC
NT-30-A through NT-350-A All -B Models
non-load manway with 16,000 lbs. highway load rating
15" threaded access
NOTE 1: 6" connections are not available with NT-30 through NT-100.
NOTE 2: NT-750, NT-1000 and NT-1500 have two covers requiring a set of two risers when ordered.
www.striemco.com | Made in the USA | Striem Catalog 24
Command Center™
pH monitoring package
The Command Center™ is the industry's only ”ready-to-use” Touchscreen Interface
pH monitoring package. Simply install the pH sensor and supply
power — that's it. The system is pre-programmed to alarm at low
and high pH values (6-9 pH) and can be adjusted as required. Up to
1 year of recorded data can be stored to the micro SD card (included) for
easy data transfer. Customizations are simple using the easy-to-navigate
menus on the color touchscreen display.
Features: ready-to-use: pre-programmed audio/visual alarm set points | touchscreen:
bright, easy-to-navigate 3.5" color touch-screen display | large memory storage: includes
two formatted micro SD cards – each card stores approximately 1 year of history | exports
to Excel: recorded data logs, alarm history, and trend data export to Excel for easy data
management | remote access: use ethernet connection to remotely manage the Command
Center™ through your company’s building management system | fresh water flush: pre-
programmed with digital output to power solenoid valve for fresh water flush if pH approaches
high/low limits | NEMA 4X lockable weather proof enclosure – temperature resistant from
32º F to 122º F | sensor maintenance and calibration kit included (CC-K) | 120 V AC power
supply required | all components are UL listed | sensor can be mounted up to 3,000 feet from
Command Center™
Command Center™
with SPK-A above grade sen-
sor placement kit
Solenoid Valve
(by others)
Cutaway of Lab Basin™
LB-275 installed above grade
with Command Center™ and
optional limestone
25 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Step 1 of 3: Select Your System
Command Center™ with 1 Sensor Command Center™ with 2 Sensors
CC-1 (10 ft. of cable) CC-2 (10 ft. of cable)
includes includes CC-K Sensor Maintenance and
CC-K (qty. 1) CC-K (qty. 1) Calibration Kit (see step 3 below) is
included with order of CC-1 or CC-2.
Step 2 of 3: Select Sensor Placement Kit
Above Grade Below Grade
SPK-A SPK-B
For installation of sensor in For installation of sensor in below grade outlet
above grade outlet drainage line drainage line. Exclusive quick disconnect feature
allows for easy cleaning or replacement of probe from
Kit Contents (depicted below) finished grade Quick
Disconnect
9" x 9" sensor port with threaded Kit Contents (depicted below)
Cable Grip
and gasketed cover access. Top assembly with dual quick-disconnect
4" plain end connections and adapter components for 2" and
Above Grade with Effluent Sensor 4" PVC connection
pH sensor port with 4" plain end connections
Flow Command 50 ft. of sensor wire with single quick
Center™ disconnect clip
Heavy duty cleanout with sidewall
Lab Basin™ 1½" and 4" PVC pipe cut to length (by others) Sensor
Below Grade with Effluent Sensor And Cable
Come with
Flow Command Command
Center™ Center™
Lab Basin™
Stabilizing
Mount for pH
Probe
Step 3 of 3: Select Accessories and Replacement Components (Optional)
Replacement Sensor with Additional Sensor Cable Quick Disconnect Clip Sensor Maintenance and Calibration Kit
10 ft. of Cable and Quick (for use with below grade (required when ordering 500 mL 7 pH buffer solution, 500 mL 10 pH buffer solution,
Disconnect Clip SPK-B, quick disconnect above grade CC-PHW for 500 mL cleaning solution, sensor brush, gloves, salt bridge,
clip not required) SPK-A) standard cell solution
CC-K (qty. 1) included
standard with order of
Command Center
(CC-1 or CC-2)
CC-PH CC-PHW CC-PHWC CC-K
www.striemco.com | Made in the USA | Striem Catalog 26
Bio Basin™ Series BB-500
BB-275
decontamination tanks
Chapter 8 of the UPC and IPC require the pretreatment of
liquid wastes likely to damage the building’s drain, waste
and vent system, public sewer or ground/surface waters.
According to the American Institute of Architects (AIA)
“water drainage must be contained and disposed of safely
to ensure that it does not enter hospital or community
drainage systems.” The American National
Standards Institute Standard (ANSI Z538.1)
says “consideration should be given to the
proper disposal of waste
flushing fluids from operating
emergency eye wash and
shower equipment.” Other
local codes may apply.
Striem recommends the following steps for sizing a decontamination tank:
Number of Supply Line Rinse Time Size of Supply Line Flow Rates
Fixtures (showers Flow Rate of (15-20 Tank in
Each Fixture minutes Gallons velocity ½ ¾
or eyewash (see table right) typical) 6.64 GPM
stations) 4 Ft./sec 3.77 GPM 9.96 GPM
13.29 GPM
Sizing Sample: 6 Ft./sec 5.66 GPM 16.61 GPM
1. A hospital with two emergency showers, each with a ¾" supply line carrying a
8 Ft./sec 7.54 GPM
flow rate of 9.96 GPM. 2 fixtures x 9.96 GPM = 19.92 GPM
2. 19.92 GPM x 15 minutes = 298.8 gallons 10 Ft./sec 9.43 GPM
3. Select Bio Basin™ model BB-500 (500 liquid holding gallons)
Bio Basin™ Covers Monitoring Packages
Covers are provided with AVA-3: Single Level AVA-4: Multi-level 80%
water/air tight gasket seal Monitoring Package Monitoring Package 50%
and are designed to fit Remote audio/ Remote audio/visual 20%
tightly into a key-fit frame. visual alarm panel alarm panel and
and explosion proof explosion proof multi-
stainless steel level float switch.
float switch.
24"
BOLTED
COMPOSITE – TRAFFIC
BB-275, BB-500-B, BB-750,
BB-1000, BB-1500
16,000 lbs. highway load rating
27 www.striemco.com | Made in the USA | Striem Catalog
specifications & submittals
formats PDF DOC DWG RFA
available
online
Made To Order – Submittal Required
Specifications
Capacity (gal.) Recommended Rough-In Dimensions (in.) Adapter Weight (lbs.)
Pipe Size Adjustability Dry Wet
Striem Inlet and Optional Optional 4" Weight Weight
Model Liquid Body Pump-out Outlet Outlet Valve Vent (add to
Holding W ID (High Connection) (Low Connection) B, D, F & H)
Inlet / Vent
Outlet L OD H A B C D EF
BB-275 275 4 2 68 33 ½ — — 51 ½ 38 13 ½ 9 42 ½ 40 11 ½ 6" 223 2,306
BB-500-B 500 4 2 — — 48 54 91 ¾ 70 21 ¾ 6 85 ¾ 76 15 ¾ 6" 455 —
BB-750* 750 6 4 6" 1200 —
BB-1000* 1000 6 4 See specifications below 6" 1400 —
BB-1500* 1500 6 4 6" 1700 —
* BB-750, BB-1000, BB-1500 are for below grade applications only
BB-275 BB-500-B
Below Grade (-B)
BB-750 Side View BB-1000 Side View BB-1500 Side View
TeleGlide™ Riser Order Guide
Desired Riser Height (in.) Risers Needed
All BB models
0-6 24 Series Adapter
>6 - 24
>24 - 39 24 Series
>39 - 43 Short Riser (SR24)
>43 - 58
>58 - 72 24 Series
Long Riser (LR24)
24 Series Short +
Short (SR24 + SR24)
24 Series Short +
Long (SR24 + LR24)
24 Series Long +
Long (LR24 + LR24)
NOTE 1: When ordered with float switch, add 2" measuring finished cover to centerline of all connections and subtract 2" from available riser height. 28
NOTE 2: BB-275 has two covers requiring a set of two risers when ordered.
www.striemco.com | Made in the USA | Striem Catalog
Appendix
Terms and Conditions
All Customers: The following terms and conditions pertain to qualified customers only.
Striem, at its option, may qualify or disqualify any customer. All prices are subject to change without notice.
International Customers: All border crossing fees are paid by the importing customer. Contact Striem for further information on NAFTA and HTS
numbers.
Credit Terms: 2% 10 days, net 30.
A 2% discount may be taken if payment is received on or before the 10th day from date of invoice. Full payment is required on or before the 30th
day from date of invoice. A 2% service charge will be applied to all overdue accounts. Accounts that regularly pay beyond net terms will be denied
open account status. All prices are subject to change without notice. Invoices may be sent via email upon request.
Freight Terms: Shipments are F.O.B. Kansas City, KS. Freight charges are pre-paid and billed with product invoice.
Returned Goods: Effective March 2 nd , 2015, standard catalog products may be returned with a Striem-issued RGA if they are in saleable
condition within 6 months of the purchase date. A 5% restock fee of the original invoiced amount will apply. The customer is responsible for
returned freight. If the product is damaged or incomplete, additional charges may apply. Made-to- order products are non-returnable.
29 www.striemco.com | Made in the USA | Striem Catalog
Notes specifications & submittals
formats PDF DOC DWG RFA
available
online
www.striemco.com | Made in the USA | Striem Catalog 30
PH 913-222-1500 [email protected]
[email protected]
STRIEMCO.COM