Brochure - VENTUS 2016

Brochure - VENTUS 2016

Keywords: Brochure - VENTUS 2016

2016

RELIABLE TOP QUALITY
AND TIGHT COMPONENTS
CONSTRUCTION

INTELLIGENT SAFETY
CONTROL OF USE
SYSTEMS

STRUCTURE

AZ 150
ALUZINC SHEET

RESISTANCE TO CORROSION

3000 2412 VENTUS AHU
2500 new coating
resistance
Number of hours
2000

1500

1000

500
162

0 Galvanised Aluzinc

20 Mu Z275 20 Mu AZ150

Salt spray test according to ASTM B-117

CASING SKIN FAN SECTION CAGE

»» metal sheet thickness increased by 20% »» increased longitudinal stiffness
»» increased rigidity and durability of the structure

of the AHU structure »» easier sections assembly
»» low absorption of heat radiation and UV
»» increased resistance to weather conditions

ALUMINIUM COLUMNS
AS STANDARD
FOR ALL TYPES
OF UNITS

Z PROFILE C PROFILE

VS 21-150 VS 180-650

GALVANIZED STEEL SUPPORT
AS STANDARD FOR ALL TYPES

OF UNITS

FRAME STRUCTURAL COLUMNS

»» easier transport »» thermal breaks on the mullion as standard
»» greater profile resistance to deflection »» high resistance to weather conditions

and UV rays

TIGHTNESS

SMART HINGE
SYSTEM

VTS PATENTED
PROPRIETARY

SOLUTION

INSPECTION PANELS EQUIPPED WITH THE OPEN / CLOSE SMART SYSTEM
AND NEW PROTECTIVE CORNERS

»» easy to use, enabling quick opening and closing of the inspection panel
»» smart hinge - prevents seal breaking when the panel is opened (VTS proprietary and patented solution)
»» improved ergonomics with an integrated handle and hinge function
»» reduced risk of panel damage

THERMAL ADDITIONAL
BREAK COLUMN
SEALING

LABYRINTH ADDITIONAL
SEALING SEALING
FINS

ALUMINIUM STRUCTURAL COLUMNS WITH AN ADDITIONAL SEALING FIN
AND A THERMAL BREAK

»» thermal breake as standard - ensures no condensation outside the AHU
»» the fin ensures labyrinth sealing - currently the most effective solution on the market,

mainly used in laboratory equipment
»» original solution consisting in the use of symmetrical channel tension filled with a sealing compound,

which provides 100% tightness of the connection between the column and construction structure

CONTROLS

NEW FEATURES

MEASUREMENT AND CONTROL ELECTRIC HEATER CONTROL
OF THE CONSTANT AIR VOLUME
»» smooth control system that adjusts
»» adjustment of the preset constant air instantaneous power to the current demand
volume under changing flow resistance -
compensation of changing internal resistance
of the AHU (e.g. with varying degrees of air
filter dirt, different setpoint of the mixing
box, etc.)

»» adjustment of the fan power to the current
needs of the installation

»» immediate readiness of the AHU to work
with the required performance immediately
after installation

CONSTANT PRESSURE CONTROL
WITH VARIABLE AIR VOLUME

»» control of constant, preset air pressure
at variable volume (efficiency change
is carried out through the air distribution
system – e.g. VAV controllers)

CO2 HUMIDITY CONTROL

»» automatic reduction of the amount »» control over air humidifying
coof nocuetsnitdreataioirn(kbeeelopwingthteheseCtOv2alue) - both evaporative and steam

»» optimisation of consumption of heat »» supports control the drying process
and electricity
MIXING BOX CONTROL
CONTROL OF VS21 – 150 BACKUP
ENGINES »» smooth control of the mixing box,
external signal or as in the CO2 control
»» adaptation to the special needs function, etc.
of the building
»» optimization of the ventilation air
»» protection in case of failure to save energy
of the first engine

MAIN and LX HMI

SMART HMI

NEW RANGE OF CONTROLLERS ULTRA+ SMART MAIN LX
• •
1 source • • •
SOURCE 2 sources • • •
OF HEATING 3 sources •
/COOLING 4 and more sources • •

COMMUNICA- TCP/IP Modbus • •
TION WITH MAS- WebServer •
TER SYSTEM BacNET • •

Dual methode of heating coil freeze protection • • •
(low limit thermostat on the air and water side) • •
Energy recovery systems frost protection • •
FUNCTIONS (temperature sensor downstreem energy recovery section) • •
Measurement and control of the constant air volume (CAV) •
Measurement and maintennance of air volume based •
on system required pressure (VAV) •
Control of the concentration of carbon dioxide in the air •
Air humidity control
Pre-heater control for extreme low temperatures
(maximization of the energy recovery performance)

SOURCES OF HEATING/COOLING »»Mixing box
»»Primary heater »»Primary heater (before recovery of heat), electric/water
»»Primary cooler »»Reheat coil (mainly used for drying)
»»The recovery (plate heat exchanger or a rotary exchanger,

glycol system)

SAFETY OF USE

HANDLE OPEN PROTECTION FAN SAFETY BARRIER

»» increased safety against accidental »» protection against fan in-operation
opening of the fan section

PANEL CLOSED Contact PANEL OPENED
Reed switch
Contact closed – fan start permitted
PLUG fan section

Contact open – fan start prohibited

Contact Contact
Reed switch Reed switch

PLUG fan section PLUG fan section

REED SWITCH
Contact
Reed switch

»» electronic stop of thPLeUG motorfan section when
the panel is opened

Contact