TEMPERATURES 97
TEMPERATURES 98
TEMPERATURES 99
TEMPERATURES 100
TEMPERATURES 101
TEMPERATURES 102
104HEATERS
105HEATERS Ordering From Band Heater
106HEATERS Ordering From Strip Heater
107HEATERS Ordering From Tubular Heater
108HEATERS Ordering From Tubular Heater
109HEATERS Ordering From Finned Heater
110HEATERS Ordering From Finned Heater
111HEATERS Ordering From Immersion Heater
112HEATERS Ordering From Cartridge Heater
Wire Heater Resistohm RESISTOHM 80 Ni 79 - Cr 20 - Si.Mn.+ CET ALLIAGE OFFRE D'EXCELLENTES PERFORMANCES JUSQU'A 1200°C OUTSTANDING PERFORMANCES AT TEMPERATURES UP TO 1200°C DENSITE / DENSITY 8.35 g.cm3 POINT DE FUSION / MELTING POINT 1400 °C TEMP.MAX.UTILISATION / MAX.OPERATING TEMP. 1200 °C RESISTIVITE / RESISTIVITY 108 mΩ.cm RESISTOHM 70 Ni 69 - Cr 30 - Si + ALLIAGE UTILISE A DES TEMPERATURES ELEVEES SOUS ATMOSPHERES OXYDANTES THIS ALLOY IS SELECTED FOR HIGH TEMPERATURE IN OXIDISING ATMOSPHERES DENSITE / DENSITY 8.16 g.cm3 POINT DE FUSION / MELTING POINT 1380 °C TEMP.MAX.UTILISATION / MAX.OPERATING TEMP. 1250 °C RESISTIVITE / RESISTIVITY 118 mΩ.cm RESISTOHM 60 Ni 69 - Cr 15 - Fe bal - Si + ALLIAGE UTILISE POUR DES TEMPERATURES NE DEPASSANT PAS 1100°C RECOMMENDED WHEN WORKING TEMPERATURE DOES NOT EXCEED 1100°C DENSITE / DENSITY 8.20 g.cm3 POINT DE FUSION / MELTING POINT 1350 °C TEMP.MAX.UTILISATION / MAX.OPERATING TEMP. 1100 °C RESISTIVITE / RESISTIVITY 112 mΩ.cm RESISTOHM 40 Ni 37 - Cr 18 - Fe bal - Si + ALLIAGE UTILISE POUR DE NOMBREUX APPAREILS DOMESTIQUES SUITABLE FOR A WIDE RENGE OF DOMESTIC APPLIANCES DENSITE / DENSITY 7.9 g.cm3 POINT DE FUSION / MELTING POINT 1380 °C TEMP.MAX.UTILISATION / MAX.OPERATING TEMP. 1050 °C RESISTIVITE / RESISTIVITY 105 mΩ.cm RESISTOHM 30 Ni 30 - Cr 20 - Fe.bal - Si. + ALLIAGE SELECTIONNE POUR PLUS FAIBLES TEMPERATURES SUITABLE FOR RESISTANCE ELEMENT AT LOWER TEMPERATURES DENSITE / DENSITY 7.95 g.cm3 POINT DE FUSION / MELTING POINT 1390 °C TEMP.MAX.UTILISATION / MAX.OPERATING TEMP. 1000 °C RESISTIVITE / RESISTIVITY 105 mΩ.cm RESISTOHM Ni – Cr 114HEATERS
115HEATERS
116HEATERS
117HEATERS
118HEATERS
Control and applied loading Wiring and setup notices 119HEATERS
120HEATERS
The weights and related dimensions of the power regulators 121HEATERS
Outline appearance and fixed dimensions 122HEATERS
Model SP48P16 SP48P26 SP48P36 SP48P46 CURRENT RATING 18A 26A 36A 46A CURRENT VOLTAGE 180~480VAG 180~480VAG 180~480VAG 180~480VAG FUSG FWC-25A10F FWC-32A10F 4SET 63FE DEMENSION 90L"57W"98H 130L"54W"98H 90L"54W"148H 130L"54W"148H WEIGHT 0.45KG 0.6KG 0.65KG 0.9KG 123HEATERS
124HEATERS
125HEATERS
126HEATERS HS - 1 ( Heat Sink ) HS - 2 ( Heat Sink ) HS - 3 ( Heat Sink ) HS - 4 ( Heat Sink ) HS - 5 ( Heat Sink )
Pressure Gauge 128PRESSURES
Pressure Gauge 129PRESSURES
Pressure Gauge 130PRESSURES
Pressure Electric 131PRESSURES
Transmitter Pressure Gauge 132PRESSURES
Pressure Gauge Diaphragm 133PRESSURES
Differential Pressure Gauge 134PRESSURES
Homogenizer Pressure Gauge Diaphragm 135PRESSURES
CTX-CTL Industrial Pressure Transmitter For OEM Application 136PRESSURES
CTX-CTL 137PRESSURES
CTX-CTL 138PRESSURES
CTX-CTL 139PRESSURES
Pressure Gauge Type 140PRESSURES
141PRESSURES Metric Pressure Measurement Pressure Units Cross Reference Chart
143CALIBRATION Calibration Services Calibration Framework
Multicalibrator ISOCAL MCS-8 Instrumentation for • Measures and generates mA, mV, Volts, Ohms, RTD, TC. • Simultaneous input and output operation. • Isolated input and output. • Interface with a Windows-based Calibration Software to provide a true Computer-Aided Calibration System with documenting capability. • Real-time data acquisition capability when connected to a computer. ISOCAL MCS-8 Universal Calibrator enables measurement and generation of signals used in instrumentation and Process Control. It is a high-accuracy instrument, having high stability features in temperature changes and long-term aging conditions. It contains useful items allowing its on field and workbench use. The calibrator also incorporates concepts of automatic checking and calibration via computer, such as report and certificate issues, automatic work management, data archiving for an overall coverage of quality procedure requirements. presys EF0211-01 08/03/2012 Phone: + 55 (11) 5073.1900 http://www.presys.com.br Fax: + 55 (11) 5073.3366 I n s t r u m e n t s I n c . E-mail:[email protected] PRESYS 144CALIBRATION
145CALIBRATION
146CALIBRATION