The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.

W E S T C A R MILANO ITALY WESTCAR PRODUCTS ROTOFLUID-CA hydraulic couplings with annular chamber and starting torque lower than nominal motor torque

Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by , 2017-01-30 01:15:03

FLUID COUPLINGS - Konaflex

W E S T C A R MILANO ITALY WESTCAR PRODUCTS ROTOFLUID-CA hydraulic couplings with annular chamber and starting torque lower than nominal motor torque

STC AR ELECTRONIC “SCD” DEVICE Sheet
FOR OVERLOAD CONTROL
MILANO 80-022A EN
ITALY
Date

05-2006
Min. 16 5±2MILANO - ITALY
WE
38 C A Rotofluid Coupling
45 B
96B Electronic controller
90 10
C Pulse initiator (2 pz. A 180°)

A D Sensor Allarm

REL. OFF WESTCAR S.r.l.

SENS. PNP ON
NPN
RES. AUT NPN
SET P. PNP
MIN MAN

MAX RESET

T 1 STOP

E 437 SET POINT Off the drive
A Dimensions
TC 8R
7A REL. OFF ON RESET
6N NPN
5G SENS. PNP PNP 1
4E NPN MAN
3 () RES. AUT SET POINT
2 2 uF SET P. MAX
1 1 uF MIN 8R
7A
ENABLE 6N
5G
D ON T 4E
3 ()
M18x1 E 437 2 2 uF
A 1 1 uF
TC
ENABLE

ON

48

“SCD” DEVICE
The “SCD” Device can be setted to guarantee the safety of coupling and machine and the product quality.
The “SCD” device is an electronic controller which receives a train of pulses by a sensor. The pulses are converted into a voltage proportional to
the pulses frequency. This voltage is compared with a variable reference voltage (SET POINT). The internal relay changes over when the input
speed is faster or lower than the fixed (SET POINT). It is emploied to control the shaft revolution speed. In case of speed decrease, the device
gives a signal to the operator.

OPERATION
As the trasmitted torque is increased, this gives rise to an increased slip of the fluid coupling. Possible overload can be detected by measuring
the resulting speed reduction in the driven half coupling by means of overload “SCD”. This with change-over contact at the output may either emit
an alarm signal or switch off the main motor. A delaying action (max 120 sec.) prevent the unnecessary triggering of the relay, when the motor is
started. It only occurs once when the operating voltage is applied. False alarms are prevented arising from very short torque fluctuations, by the
introduction of a preset time lag (max. 30 sec.)

SUPPLY
50÷60 Hz - Tolerance: -10%÷+6% - 24Vac STANDARD (115Vac or 230 Vac on request)- How to order: SCD 24 Vac

49

STC AR INSTRUCTIONS FOR MOUNTING ROTOFLUID Sheet
WE MILANO - ITALY COUPLING ON THE MOTOR SHAFT
MILANO 90-004A EN
ITALY D
A Date

05-2006

TAPPED HOLE DIMENSIONS FOR STANDARD ELECTRIC MOTOR SHAFTS

MOTOR SHAFT DIAMETERS “D”

Dimensions Ø 55 Ø 90
“A” Ø 60
Ø 14 Ø 19 Ø 24 Ø 28 Ø38 Ø42 Ø 65 Ø 100 Ø 140
Ø 48 Ø 70 Ø 110 Ø 160
Ø 75 Ø 125
Ø 80
Ø 135

M5 ●

M6 ●

M8 ●

M 10 ●

M 12 ●

M 16 ●

1 M 20 ●
M 24 ●

M 36 ●

65

13
42

Fig. 1 Fig. 2

For the mounting of the ROTOFLUID coupling to the motor it is indispensable to operate on the shaft (1) of the coupling to avoid axial stress on
the bearings. It is recommended to fix on the motor shaft a screw stay (2) on which a nut (3) is tightened possibly resting to a thrust bearing (4)
(see Fig.1).
It is indispensable to lubricate the motor shaft before mounting the coupling.
Check that the coupling shaft rest on the motor shaft shoulder and lock by means of screw (5), spacer (6) (see Fig.2)

1 M 4R B
4

2 B 5
3
Fig. 1 Fig. 2 Fig. 3

1) 1) Demount the ROTOFLEXI rubber element (F) as shown at Fig.1
2) 2) Fit the ROTOFLUID hydraulic coupling (A) on the motor shaft(M), fit the ROTOFLEXI hub (B) on the driven shaft ©. Assure that the driven

shaft is coaxial with the hydraulic coupling (A). The concentricity is assured when it is possible to fix the hub (B) to the hydraulic coupling flange
(A) by means of the screw (D), as shown at Fig.2. It is now possible to fix definitely the motor and the driven machine checking that between
the hub (B) and the driven shaft shoulder there must be a space (E) equal to the thickness of the rubber element (F).
3) Remove the screws (D), move the hub (B), place the rubber element (F), lock the screws (G) and (H) as shown at Fig.3.

50

WE STC AR MILANO - ITALY INSTRUCTIONS FOR PULLING OFF ROTOFLUID Sheet
COUPLING FROM THE MOTOR SHAFT
MILANO 90-005A EN
ITALY
Date

05-2006

SCREW PULLER “VE”TYPE ROTOFLUID COUPLING
TYPE
Fusible plug SISTEM SIZE K
“VE” K1
K3
VE M14 20 -

VE M16 20 ALL
VERSIONS
VE M20 20
UP TO Ø 65
30 FOR Ø75 Ø 80

30P ALL
VERSIONS
VE M24 40P

50

55

55

VE M30 60

65

32 70P
75P

Oil plug VE M36 80P
85P

- To pull off the ROTOFLUID coupling proceed as follows: 90P
- Remove the screw plug or the tightening screw from the shaft end. 95P

- Tight the screw pullerÇ in the shaft threaded holeÉ checking that the motor shaft is locked.

PULLING OFF SYSTEM “SE”TYPE ROTOFLUID COUPLING

SISTEM SIZR TYPE

“SE” KZ JH X
X 103
SE M20 20 - - J 103 H 85

SE M24/35 30

30P ALL

SE M24/40 40P VERSIONS

50

55 UP TO Ø 65

55 FOR Ø75 Ø 80

SE M30 60

65

70P

52 SE M36 75P ALL
80P VERSIONS

3 85P
6 90P

- To pull off the ROTOFLUID coupling proceed as follows: 95P

- Remove the screw plug or the tightening screw from the shaft end.

- Lock the bush (5) to the shaft end (3) with 2 securing screws.

- Tight the screw puller (2) in the shaft threaded hole keeping locked the rod (6) to avoid the motor shaft rotation.

PULLING OFF SYSTEM
“SE” TYPE

The figure 1 shows
ROTOFLUID® coupled in
line with ROTOFLEXI®.
This kind of assembly
permits the great advantage
to replace the rubber
elements without moving the
transmission components
from their position (Fig.2)

Fig. 1 Fig. 2

51

WE STC AR MILANO - ITALY ROTOFLUID COUPLINGS OUTLINE AND MAIN Sheet
COMPONENTS
MILANO 90-018A EN
ITALY
Date

05-2006

COUPLING ALFA Fig. 1 ROUND SINGLE IMPELLER COUPLINGS Fig. 2
10 K1
20 K1 COUPLING ALFA
30 K1
30P K1 10 K3
40P K1 20 K3
30 K3
30P K3
40P K2
COUPLING BETA
10 Z
20 Z
30 Z-X-J-H
30P Z-X-J-H
40P Z-X-J-H

HOLLOW HOLLOW
SHAFT SHAFT

HOUSING EXTERNAL
COVER IMPELLER

INTERNAL INTERNAL
IMPELLER IMPELLER

EXTERNAL HOUSING
IMPELLER COVER

SINGLE IMPELLER COUPLINGS Fig. 3 TWIN IMPELLER COUPLINGS Fig. 4

COUPLING ALFA COUPLING ALFA
50 K2 55 K2
60 K2 65 K2
70P K2 75P K2
80P K2 85P K2
90P K2 95P K2
COUPLING BETA
COUPLING BETA 55 Z-X-J-H
50 Z-X-J-H 65 Z-X-J-H
60 Z-X-J-H 75P Z-X-J-H
70P Z-X-J-H 85P Z-X-J-H
80P Z-X-J-H

HOLLOW HOLLOW
SHAFT SHAFT
HOUSING
HOUSING EXTERNAL
EXTERNAL IMPELLER - F
IMPELLER - F
INTERNAL
INTERNAL IMPELLER
IMPELLER HOUSING
EXTERNAL
HOUSING IMPELLER - M
COVER
52

WE STC AR MILANO - ITALY RECOMMENDED Sheet
SPARE PARTS
MILANO 90-022A EN
ITALY
Date

05-2006

ROTOFLUID ROTOFLUID SCF ROTOFLUID DCF
COUPLING COUPLIG COUPLING

SPARE PARTS FOR ALFA AND ALFA COUPLING AND FLEXIBLE COUPLING 10
BETA COUPLINGS 9
4 5 88
1 OILSEALS KIT 7
2
2 BEARINGS KIT 1

6 FR-V AB
1 TYPE LR-V Brake Disc PA

3 SEEGER RINGS KIT 2

4 NUTS KIT 5 Brake Drums
5 OIL PLUG AND SCREWS KIT TYPE K FRD AFF

FR-PAV

BETA COUPLING

TYPE J H XZ

6 FUSIBLE PLUG (1)

SPARE PARTS FOR FLEXIBLE COUPLING

8 FLEXIBLE COUPLING 9 PINS WITH RUBBER 10 RUBBER BUFFER
WITH SCREW
FOR ROTOPIN COUPLINGS
(1) QUOTE TEMPERATURE FOR ROTOFLEXI FOR ROTOPIN COUPLINGS AB
120 °C - 145 °C - 180 °C COUPLINGS AB AFF
AFF
7 THERMAL TRIP PLUG (1)

(1) QUOTE TEMPERATURE LRV
120 °C - 145 °C - 180 °C FRV
FRD

FR-PAV

For transmission oil characteristic see installation and maintenance manual.
To order spare parts indicate coupling type and identification code or see pag.3 of instruction manual.

53

WE STC AR MILANO - ITALY OPTIONAL FUNCTIONS Sheet

MILANO 10-060A EN
ITALY
Date

05-2006

THE OPTIONAL FUNCTIONS ROTOFLUID COUPLING OPTIONAL FUNCTIONS
WILL MODIFY THE BASIC
CODE OF THE SIZE VERSION HOLE
STANDARD COUPLING
BORE
D [ [

HORIZONTAL SHAFT Standard
MOUNTING
C1
VERTICAL SHAFT MOUNTING
MOTOR SHAFT UP WARDS C2

Standard
VERTICAL SHAFT MOUNTING
MOTOR SHAFT DOWN WARDS R

C1 Standard
OIL FILLING PLUG PARALLEL
TO THE COUPLING SHAFT V

OIL FILLING PLUG RADIAL ZZ
TO THE COUPLING SHAFT OIL Standard

I
NBR OIL SEALS FOR MAX. 120°C B
(WITHOUT STRENGTHENING RINGS)
Standard
VITON OIL SEALS FOR G
MAX 200°C
Standard
STRENGTHENING AND PROTECTING E
RINGS FOR OIL SEALS

OIL FOR TEMPERATURES FROM
-20°C TO +180°C.
NONFLAMMABLE OIL (I)
OIL FOR TEMPERATURES FROM
-40°C TO +160°C (B)

BEARINGS LUBRICATION WITH
TRANSMISSION OIL

FORCED BEARINGS LUBRICATION
WITH GREASE/OIL

COUPLING ARRANGED FOR
DISASSEMBLING WITH EXTRACTION
SCREW


COUPLING ARRANGED FOR
DISASSEMBLING WITH
“S.E.” SYSTEM (E)

54

WE STC AR MILANO - ITALY APPLICATION REQUIREMENTS Sheet

MILANO 10-059A EN
ITALY
Date

05-2006

CUSTOMER NAME ............................................................................................................................................................................................................................................................
APPLICANT ............................................................................................................................................................................................................................................................................
ADDRESS ...............................................................................................................................................................................................................................................................................
PHONE No. ................................................................. FAX ................................................................................... E-MAIL ..................................................................................

MOTOR DATA

Electric motor size ............................................................................................................................................. kW ................................................ RPM ................................
Shaft diameter mm ..................................................................................... Length mm. ................................................................................. Key .............................

Diesel engine type .............................................................................................................................................. kW ............................................... RPM ..............................
Flyweel dimensions (SAE) ...............................................................................................................................................................................................................................................
Housingdimensions(SAE) ....................................................................................................................................................................................................................

MACHINE DATA

Machin type ..........................................................................................................................................................................................................................................

Application type ❑ in line (pag.11)

❑ with pulley (pag.29)

Driven shaft diameter mm.................................................................................................................... Length mm...................................................................................

Pulley: Pitch diameter mm .......................................................................... Grooves section and number ...........................................................
Mounting:
❑ horizontal ❑ vertical ❑ motor shaft up wards

❑ motor shaft down wards

FURTHER DETAILS

Required power when running kW .............................................................................................................................................................................................................................

Starts at full load: ❑ yes ❑ no

Start-Stop Cycle .....................................................................................................................................................................................................................................................................

Reversal Cycle ..............................................................................................................................................................................................................................................................

Overload Cycle ................................................................................................................................................................................................................................................................

Load inertia (kgm2) .............................................................................................................................................................................................................................................................

Load speed RPM ................................................................................................................................................................................................................................................................

Required acceleration time: Full load ...........................................................................................................................................................................

Empty .................................................................................................................................................................................

Room temperature °C ......................................................................................................................................................................................................................................................

Environmental conditions ...............................................................................................................................................................................................................................................

Specify eventual required options

Please enclose application description and sketch

55

WE STC AR MILANO - ITALY APPLICATIONS Sheet

MILANO 10-052A EN
ITALY
Date

09-2005

Building-Construction-Surface Mining-Bricks FIELDS OF APPLICATION
• Tower cranes
• Bridge cranes Paper Processing
• Belt conveyors • Winders
• Armored chain conveyors • Pulpers
• Screw conveyors • Cardboard making machinery
• Slat conveyors • Mixers
• Bucket wheel excavators
• Bucket elevators Timber Processing
• Concrete mixers • Drum barkers
• Rotating screens • Hardboard presses
• Rolling mills • Shredders
• Brick moulders • Playwood presses
• Power trowels
• Stone crushers Plastic and Rubber
• Centrifuge for concrete piles • Crushers
• Hammer and barrel mills • Screw extruders
• Calenders
Textile • Rolling presses
• Drum tumblers • Mixers
• Centrifuges • Muddlers
• Industrial washing machines
• Driers Cement Mill
• Carding machines • Rotating kilns
• Spinning machines • Belt conveyors
• Combing machines • Bucket elevators
• Raising machines • Fan blowers

Chemical – Foodstuff Marble
• Centrifuges • Gantry cranes
• Centrifugal separators • Multi-blade frames
• Decanters • Diamond wire saw
• Rotating filters
• Mixers Ceramics
• Stirrers • Continuos and intermittent ball mills
• Soap cutters • Mixers
• Bottling plants • Presses
• Disc driers
• Waste slaughterhouses braker The Ecology
• Blenders
Mechanical Engineering • Sludge purification plant
• Twisting machines for rope and wire
• Rod iron straighteners Others
• Presses • Winches
• Profiling machines • Windlasses
• Drawbenches • Centrifugal and alternative compressors
• Cutters • Suction and centrifugal fans
• Centrifugal pumps
Automotive Industry • Fire pumps
• Balancing machines • Elevators
• Tow conveyors • Cable cars
• Overhead chain conveyors • Amusements park rides
• Gates open/closing drive • Haulage wagons in steelworks and mines
• Chain conveyors • Stack-up coating plants
• Car parking elevators • Sprayers
• Refineries
• Ski lift
Sand mixers

56

APPLICATIONS W ESTC AR

MILANO
ITALY

Elevator winch

Rotating dryer

Shredder

Belt conveyor

Australia WESTCAR WORLD WIDE Romania
Austria Singapore
Belgium Great Britain Slovenja
Canada Holland South Africa
Ceka Republik Hungary Spain
China - Shanghai India Sweden
Cyprus Indonesia Switzerland
Denmark Iran Taiwan
Egypt Israel Thailand
Finland Korea Turkey
France Malaysia U.S.A.
Germany New Zealand
Norway
Portugal

Distributor

WE STC AR s.r.l.

MILANO
ITALY

WESTCAR s.r.l. Via Monte Rosa, 14 - 20149 MILANO (Italy)

Tel. +39 02.76.11.03.19 r.a. - Fax +39 02.76.11.00.41
E-mail: [email protected] - www.westcar.it


Click to View FlipBook Version