Freedom Panel
FP3LF011100F; FP3LF011101E; FP3LF011101F; FP3LF011110F; FP3LF011111E;
FP3LF011111F; FP3LFR11100F; FP3LFR11101E; FP3LFR11101F; FP3LFR11110F;
FP3LFR11111E; FP3LFR11111F; FP3DF011100F; FP3DF011101E; FP3DF011101F;
FP3DF011110F; FP3DF011111E; FP3DF011111F; FP3DFR11100F; FP3DFR11101E;
FP3DFR11101F; FP3DFR11110F; FP3DFR11111E; FP3DFR11111F; FP6LF011100F;
FP6LF011101E; FP6LF011101F; FP6LF011110F; FP6LF011111E; FP6LF011111F;
FP6LFR11100F; FP6LFR11101E; FP6LFR11101F; FP6LFR11110F; FP6LFR11111E;
FP6LFR11111F; FP6DF011100F; FP6DF011101E; FP6DF011101F; FP6DF011110F;
FP6DF011111E; FP6DF011111F; FP6DFR11100F; FP6DFR11101E; FP6DFR11101F;
FP6DFR11110F; FP6DFR11111E; FP6DFR11111F
Hardware Reference Guide
1 Table of Contents
2 Part Identification.................................................................................................................................................... 2
3 Mounting Instructions ........................................................................................................................................... 2
4 Wiring Instructions.................................................................................................................................................. 2
5 Input Resistive Switches........................................................................................................................................ 3
6 Manufacturer Information.................................................................................................................................... 3
7 Supporting Documentation................................................................................................................................. 3
8 NexRev Visio Symbol ............................................................................................................................................. 3
9 NexRev Wiring/Connection Standards ............................................................................................................ 6
FreedomPanel_ver1 14 July 2015 1 of 7
2 Part Identification
3 Mounting Instructions
Typically located in Electrical Rooms or the Manager’s office, the exact location varies by customer.
Please refer to your SOW or contact your Project Manager for the exact mounting locations.
The Freedom Controller should always be mounted at a height of 6’ to the top of the panel.
*Conduit should never be installed on the top of the panel, only on the sides.
4 Wiring Instructions
22AWG wire for inputs, 18 AWG for outputs
FreedomPanel_ver1 14 July 2015 2 of 7
5 Input Resistive Switches
Input Resistave Switches need to be set to “On” when using 4-20mA inputs
6 Manufacturer Information
NexRev
http://nexrev.com/
1-888-967-5224
7 Supporting Documentation
This product is custom built by NexRev.
8 NexRev Visio Symbol
FreedomPanel_ver1 Communication Terminals 3 of 7
14 July 2015
Output / Overrides
FreedomPanel_ver1 14 July 2015 4 of 7
Inputs
FreedomPanel_ver1 14 July 2015 5 of 7
9 NexRev Wiring/Connection Standards
Communications
Outputs wired from Power Panel or External Power Supply
Outputs wired from NexRev Lighting Contactor Panel
(Output Wire Color will Vary)
FreedomPanel_ver1 Outputs wired as Dry Contacts 6 of 7
14 July 2015
Input wired as Thermistor / Dry Contact
Input wired as 4-20mA
Input wired as 0-10VDC
FreedomPanel_ver1 14 July 2015 7 of 7