SPLIT SYSTEMS PAGE

BLANC - WALL MOUNTED 6

MISSION - WALL MOUNTED 8

ULTIMATE COMFORT - WALL MOUNTED 10

DUCT 12

COMPACT ROUND FLOW CASSETTE 14

SUPER SLIM ROUND FLOW CASSETTE 16

CEILING AND FLOOR 18

SPLIT SYSTEMS QUICK REFERENCE GUIDE 20

FREE MATCH MULTI SERIES 22
25
FREE MATCH OUTDOOR / INDOOR UNITS 26
COMBINATION TABLES
FREE MATCH MULTI QUICK REFERENCE GUIDE

VRF OUTDOOR

MINI VRF FULL DC INVERTER 30

V4 PLUS R HEAT RECOVERY 34

V6 HEAT PUMP 40

CONTROLLERS 48

BRANCH JOINTS 50

MODE SWITCH (MS) BOX 52

VRF INDOOR 56
58
WALL MOUNTED 60
ROUNDFLOW 4-WAY CASSETTE 62
ROUNDFLOW COMPACT CASSETTE 64
CEILING AND FLOOR 66
FLOOR STANDING 68
FRESH AIR PROCESSING UNIT 70
LOW STATIC PRESSURE DUCT 72
MEDIUM STATIC PRESSURE DUCT 74
HIGH STATIC PRESSURE DUCT 76
HEAT RECOVERY VENTILATOR
DX INTERFACE KITS

WARRANTY TERMS 78

SPLIT SYSTEMS ICONS GUIDE 79

ABOUT MIDEA GROUP

Established in 1968 Midea have grown to be the World’s No. 1 Midea have 18 domestic manufacturing bases, and an
brand of HVAC products, 1 in every 5 air conditioning systems additional 15 bases in 12 other countries outside of China.
made globally are manufactured by Midea. This has resulted
in over 40,000,000 systems being sold annually, to put that Fortune Magazine named Midea as 2018’s fastest growing
in context the UK Air Conditioning market installs less than business within the world’s top 500 companies.
250,000 systems each year.
In 2018 Midea launched the Worlds 1st Eco-Friendly air
Midea annual sales in the last 10 years have grown from $12bn conditioner and became the 1st manufacturer to receive
to $36bn per annum based on a simple strategy of providing the Eco-Friendly Blue Angel certification from the German
innovative, affordable, robust and reliable air conditioning Environment Agency.
products. With production facilities in 12 countries, served by
Midea owned German robotic automation, Midea are able to Each year, Midea wins 40+ design awards at different global
provide global manufacturing accuracy that is only matched design shows such as reddot, iF, and Good Design Award. Midea
by companies such as BMW and Mercedes Benz. has also landed many high-profile projects, including 12 of the
stadiums at the 2016 Rio de Janeiro Olympic Games. Midea are
Midea manufacture a wide range of equipment including; 1kW to also the official supplier at 7 of the 12 stadiums at the 2018
70kW DX split systems, 3HP to 88HP VRF, 25kW to 2000kW Air FIFA World Cup in Russia, utilising the Midea water-cooled screw
Cooled Chillers, 365kW to 985kW Water Cooled Screw Chillers, chillers, VRF and fan coil units to provide an even more enjoyable
200m3/hr to 240,000 m3/hr AHUs and even the world’s most experience for athletes and spectators. Midea equipment can
economical 7000kW Centrifugal Chiller and so much more. In be operated in a wide temperature range, from -32oC to +67oC,
2016 Midea acquired ownership stakes in Clivet Italy (80%), placing them as the perfect choice for Air Conditioning in some
Toshiba Life Style Corporation Japan (80%) and Germany’s of the world’s harshest climates as seen in Russia or even in the
Largest Robotic manufacturer KUKA (95%). mildest of climates as found in the UK.

5 Star Hotels

5 Star Atlantis Hotel Dubai 5 Star Hilton Hotel Barcelona 5 Star NH Laguna Palace Hotel Italy

5 Star Stadiums

Camp Nou Barcelona 7 Stadiums at the 2018 FIFA World Cup Russia 12 Stadiums at the 2016 Olympics Rio Brazil

World’s Largest VRF Projects

UAE 5000 Villas Accommodation Beijing Capital Airport Forest City Malaysia

Midea is implementing its strategy to continue as a highly dynamic enterprise, with the aspiration for consistent growth that
is characteristic of a world class business.

3

ABOUT MIDEA UK Periodically maintaining our products after being professionally
installed will then not only offer the end user the lowest possible
The Midea UK business is headed up by General Manager long-term running costs, it will also prevent unnecessary and
Steve Robinson who has built a distribution sales team avoidable wear and tear of the equipment, leading to significantly
passionate about delivering market-leading products that reduced life cycle costs. To encourage this process all Midea UK
are supported fully by a unique Mi-Pro partnership program. customers benefit from the 1st refrigerant contribution scheme
in the industry. Additionally, for Mi Pro partners who take good
In the words of Steve Robinson, the Midea UK philosophy is care of our products and register their installation, they can also
set out as follows: benefit from 1st year maintenance contributions, incentivising
the promotion and securing of long-term end user service
“Our primary focus is developing successful and lasting agreements for optimal equipment performance over time.
relationships with installation partners by offering all of the
product training and technical support they could hope to The Mi Pro rewards for our partners and their end users pay
receive, and then rewarding those who go on to install our for themselves - this is a win-win for both the Midea brand
products correctly and take care of them effectively. Our key and professional installer, as well as the end user. A true
message to installers and end users is that if our products business partnership.”
are installed and commissioned professionally with the
correct refrigerant charge, they will operate at optimum
efficiency from day one.

Midea are the largest and fastest growing supplier of Chinese
branded air conditioning products in the UK.

Midea UK Newcastle Office Mi Pro UK TDraiinfinfgeArceadnemtyiating the Midea Brand Midea UK London Office

Qualifying Mi Pro installation partners can offer 10 Year Warranty Next Day Spares
their end users warranties of up to 10 years*. Free Training 1st Year Service Contributions

This is available to installation partners when our Commissioning Support
philosophy of correctly installing, recording and
maintaining the equipment is upheld. Refrigerant Contributions

The benefits available to our Mi Pro Partners are:

1. Refrigerant contribution scheme paid at £32/kg. Values are paid up to the maximum piping length of every split system**
2. Mi Points reward scheme with optional 1st Year Maintenance Contributions, encouraging end user maintenance agreements**
3. VRF commissioning support as standard
4. Included product training at our UK Academy or field based during product installation
5. 10 Year Warranty*
6. Next Day spare parts on all Midea UK supplied products

*Dependent on Mi Pro Partner Status
**Fixed values shown within this price catalogue

4

SPLIT SYSTEMS

BLANC - WALL MOUNTED
MISSION - WALL MOUNTED
ULTIMATE COMFORT - WALL MOUNTED
DUCT
COMPACT ROUND FLOW CASSETTE
SUPER SLIM ROUND FLOW CASSETTE
CEILING AND FLOOR

5

BLANC SERIES

Ultimate
Blanc (S
Mission

Sensed Temp 26°C Sensed Temp 26°C

Cassette

‘Follow Me’ active ‘Follow Me’ inactive

‘FOLLOW ME’ SENSITIVE COOLING DUAL PURIFICATION SYSTEM Duct (Sp

Keep the remote close to you and it will measure the air Double protection - dual filters remove dust and absorb
temperature around you to deliver perfectly adjusted harmful particles and bacteria, giving you cleaner, fresher air.
comfort levels.
AUTOMATIC SELF CLEANING
ONE TOUCH ‘SUPER COOL’ FUNCTION
The cooling fins are cleaned and dried automatically, keeping
This quick one-touch function flash cools the room it functioning at its best and prolonging the life of the unit.
for instant comfort – cold air within 60 seconds.
APP REMOTE CONTROL
SWEET DREAMS
Control the air conditioner and set timers easily through the
‘Sweet Dreams’ guarantees a good night’s sleep by adjusting app on your smartphone.
the air conditioner according to your body temperature. ‘Do not
Disturb’ mode will switch off the LED display and provide a quiet Ceiling/
sleep breeze.

6

BLANC SERIES

e Comfort (Split) Mi Fi Ready

Optional Intelligent Cool Bill Control Humidity Control Quiet Control Fresh Air Skin Moisturizing Bacteria & GA Stepless High Density
WiFi Control Dust Removal Comfort Technology Filter

Cold Catalyst Follow Me 2-way Smart Reminder Weekly Timer Louver Position Refrigerant Auto Restart Frost
FilteInr door unit Draining Memory Leakage Detect Function Protection

Outdoor unit Remote control

Split)

WiFi Super Cool Flash Three-Dimensional iECO Mode Gear Change “Diamond-Edged” Frost Refrigerant Self-diagnosis and
Control Cooling/Heating Airflow Casing Protection Leakage Detect Auto-protection

Follow Me Sweet Dreams High Density Cold Catalyst Self-cleaning 2-way Auto Restart 24h Anti-cold Self Clean
Filter Filter Draining Function 24-hour Timer Air Function

INDOOR MA-09NXD0-I MA-12NXD0-I MA-18NXD0-I MA-24NXD0-I

(Split) OUTDOOR MA-09N8D0-O MA-12N8D0-O MA-18N8D0-O MA-24N8D0-O

e (Split) Nominal Cooling Capacity (min-max) kW 2.6 (1.02 - 3.22) 3.5 (1.08 - 4.10) 5.3 (1.91 - 6.14) 7.0 (2.65 – 8.25)
plit)
Nominal HeatAinrcgtiCcaFpoax cRietym(omtein-maBxi)ll Control WkiWFi Control Turbo3M.0o(d0e.82 - 3.H3i7gh) Density Cold C4a.t0al(y1s.t08 - 4.2F2o)llow Me 2-w5a.7y (1.4 - 6S.m91a)rt Reminder 7.6 (2.91 - 8.53)
UK Total Cooling Capacity kW Filter Filter 3.94 Draining 5.91 7.4
3.06

Power supply (indoor power via outdoor) V-Hz-Ph 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph

Cooling Current (min-max) A 3.3 (0.4-5.4) 5.1 (0.5-6.9) 7.1(0.8-10.3) 10.6(4.3-15.4)

Heating Current (min-max) A 3.4(0.4-5.2) 4.8(0.5-6.9) 6.7(0.9-10.5) 10.5(4.57-13.5)
Max. currentSmart Sleep Curve SmaArt Diagnosis “DiamCoansdin-Egdge1d0” Weekly Timer 17.5
Quiet Mode LouMveermPoosryitio1n0 Refrigerant AuFtuonRcetisotnar1t 3.5 Frost 20
A 16 Leakage Detect Protection

Outdoor Recommended Fuse Size 16 16

Interconnecting/Indoor Power Wiring No. 5 Core 1.5mm 5 Core 1.5mm 5 Core 1.5mm 5 Core 2.5mm

Seasonal Efficiency SEER/Class W/W 6.2/A++ 6.1/A++ 6.6/A++ 6.1/A++

Seasonal Efficiency SCOP/Class W/W 4.9/A++ 4.6/A++ 4.9/A++ 4.8/A++

Indoor air flow (Hi/Mi/Lo) m3/h 520/460/340 600/500/360 860/690/560 1050/860/700

Indoor sound pressure level (Hi/Mi/Lo/Si) dB(A) 36/30/26/21 38/34/28/22 43/36/30/22 47/40/33/22

Dimension (W*D*H) mm 805x205x285 805x205x285 958x223x302 1038x235x325

Indoor unit Packing (W*D*H) mm 870x285x360 870x285x360 1035x305x380 1120x405x330

Net/Gross weight Kg 7.9/10.3 7.9/10.3 10.3/13.3 12.8/16.2

Outdoor air flow m3/h 1700 1700 2000 3000

Outdoor sound pressure level dB(A) 50 50 51 54

OptionaDl imensi3o6n0(˚WA*irD*H) Remotemm Error Alarm 70Tw0ixn270x550Refrigerant Louver Po7si0ti0onx270Fxr5es5h0Air Temperature 80A0nxt3i-3co3lxd554 Low Ambient Emer8ge4n5cxy363x70Bu2ilt-in Wired Ce
WiFi Control Flow Panel Enable Port Port Combination Leakage Detect Memory Inlet Compensation Air Function Cooling Use Function Drain Pump Control M

Outdoor unit Packing (W*D*H) mm 815x325x615 815x325x615 920x390x615 965x395x765

Net/Gross weight Kg 22.7/25.2 22.7/25.2 34/36.7 51.5/54.5

Type R32 R32 R32 R32

Refrigerant GWP 675 675 675 675

Charged quantity Kg 0.5 0.5 1.0 1.6

Additional Charge g/m 12 12 12 24
FreInslhetAΦir6.35CT/oeΦmm1pp2ee.n7rsa(at1ut/iro4en”/1A/i2Ar n”F)tui-nccotlidon Φ9D2.r5a-w2ina/iyΦng15.9(3/8T”i/m5e/r8”)
WOiFpitCioonnatLlrioqluAiPddrejsusisdsteua/rbelGeSaSwstiatsctihidceEnRaebmleoPtmeormt (iEnrcrho)r Alarm PΦor6t.3C5o/mΦTb9wi.ni5na2ti(o1n/4”W/3ire/d8”C)ontrol LeRaΦekaf6rgi.ge3e5Dra/enΦtet9c.t5L2o(u1Mv/e4erm”P/oo3sr/yit8io”n) Low Ambient U
30 50 Cooling

Refrigerant piping Mlenagx.threfrigerant pipe m 25 25

Max. height difference m 10 10 20 25

Thermostat type Remote Control Remote Control Remote Control Remote Control

aOtpuerreation temper- Indoor (cooling/ heating) °C 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30
Outdoor (cooling/heating) °C -15~50/-25~30 -15~50/-25~30 -15~50/-25~30 -15~50/-25~30

PRICE £ 530.00 610.00 900.00 1,310.00

Mi Points 9 12 18 24

/Floor (SpliNNt)oommiinnaall Conditions: Cooling; indoor 27°C DB, 19°C WB, outdoor 35°C DB, 24°C WB. UK Conditions: Summer: indoor 21°C DB, 15°C WB, outdoor 27°C DB.
Conditions: Heating; indoor 20°C DB, outdoor 7°C DB, 6°C WB. Sound Pressure is measured 1.0m below the air-outlet at Nominal Conditions.

Optional Remote Error Alarm Port Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Optional Wired Central Control
WiFi Control Enable Port Combination Leakage Detect Memory Inlet Compensation Air Function Cooling Use Function Drain Pump Control Management

7

MISSION SERIES

B
M

C
D

Powerful and rapid cooling FLASHCOOL TECHNOLOGY C

SLEEK AND ELEGANT DESIGN The high frequency start-up system generates
a strong flow of cool air in a very short time.
A curved and streamlined exterior that will fit into any
interior, with air outlet and display screen discreetly hidden. APP REMOTE CONTROL

ENERGY SAVING TECHNOLOGY Control the air conditioner and set timers easily
through the app on your smartphone.
A highly efficient inverter system and iECO energy saving
technology make this air conditioner very economical to run. SMART DIAGNOSTIC

THREE-DIMENSIONAL AIRFLOW Automatic monitoring system that detects and diagnoses
errors at an early stage. Error codes are clearly indicated
The directional air outlet moves automatically to for fast service.
direct airflow to every corner of the room.

8

Cold Catalyst Follow Me 2-way Smart Reminder Weekly Timer Louver Position Refrigerant Auto Restart Frost
Draining Memory Leakage Detect Function Protection
MISSION SERIESFilter

Blanc (Split)

WiFi Super Cool Flash Three-Dimensional iECO Mode Gear Change “Diamond-Edged” Frost Refrigerant Self-diagnosis and
Control Cooling/Heating Airflow Casing Protection Leakage Detect Auto-protection

24h

Follow Me Sweet Dreams High Density Cold Catalyst Self-cleaning 2-way Auto Restart 24-hour Timer AiAr nFtui-nccotlidonRemote control
Filter Filter Draining Function
Indoor unit

Outdoor unit

Mission (Split) WiFi Control Turbo Mode High Density Cold Catalyst Follow Me 2-way Smart Reminder Mi Fi Ready
Filter Filter Draining
Self Clean Arctic Fox Remote Bill Control

Low Ambient Smart Sleep Curve Quiet Mode Smart Diagnosis “Diamond-Edged” Weekly Timer Louver Position Refrigerant Auto Restart Frost
Cooling Casing Memory Leakage Detect Function Protection

INDOOR MB-09N8D6-I MB-12N8D6-I MB-18N8D0-I MB-24N8D0-I

OUTDOOR MBT-09N8D6-O MBT-12N8D6-O MB-18N8D0-O MB-24N8D0-O

Nominal Cooling Capacity (min-max) kW 2.6 (1.02 - 3.3) 3.5(1.37 - 4.5) 5.3 (1.96 - 6.21) 7.0 (2.11 - 8.44)

Nominal Heating Capacity (min-max) kW 3.0 (0.82 - 3.75) 4.0 (1.06 - 4.9) 5.7 (1.96 - 6.97) 7.6 (1.55 - 9.43)

UK Total Cooling Capacity kW 3.15 4.26 5.82 7.67

Power supply (indoor power via outdoor) V-Hz-Ph 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph

Cooling Current (min-max) A 2.98(0.35-4.78) 4.19(0.5-7.2) 7.1(0.7-9.7) 9.58(1.7-12.6)

Heating Current (min-max) A 2.83(0.32-4.32) 4.19(0.5-6.4) 6.5(1.0-10.1) 8.82(1.0-17)

Cassette (SpMlaixt.)current A 9.0 10.0 15.0 16.0

Outdoor Recommended Fuse Size A 16 16 16 20

Interconnecting/Indoor PoWwOieFpritCiWooninraitnlrogl 360˚ Air NoE.nRaebmleoPteort ErroPr oAr5ltarCmore 1C.o5mmTbwminination LeRaekafrgigeeDraentet ct5LoCuoMvreeerm1P.oo5srmyitimon Fresh Air CToemmpp5eenrCsaoaturteiroen1.5mAiArmnFtui-nccotlidon LowCoAomlibnigen5t CoUrEseme2eF.ru5gnmecnmtcioyn Built-in Wi
Seasonal Efficiency SEER/Class Flow Panel Inlet 7.0/A++ 7.0/A++ Drain Pump Con

W/W 8.0/A++ 8.0/A++

Seasonal Efficiency SCOP/Class W/W 5.1/A++ 5.3/A++ 5.4/A++ 5.1/A++

Indoor air flow (Hi/Mi/Lo) m3/h 440/370/240 500/440/270 750/590/500 1050/700/550

Indoor sound pressure level (Hi/Mi/Lo) dB(A) 35/29/22 36/33/27 40/35/31 44/38/29
mm 730x198x293 810x200x300 980x225x325 1090x235x338
Duct (Split) Dimension (W*D*H)

Indoor unit Packing (W*D*H) mm 810x285x375 890x285x385 1055x305x405 1165x420x315
Outdoor air flow FreInslhe1tA0i.r7/14CT.o3emmppeenrsaatutiroen
NWeOti/FpGitCirooonsnastlrowleiAPgdrhejutssstuarbeleSSwtiatcthicKgEnRaebmleoPteort Error Alarm P7o.4rt/9C.8omTbwinination Wired Control Le8Rae.k3afr/gi1gee1Dr.a2entet ct Louver Position Anti-cold 13/D12r6a-wi.n7aiyng Timer Low Am
Memory 2100 Air Function Coo

m3/h 1980 1980 3300

Outdoor sound pressure level dB(A) 49 49 49 54

Dimension (W*D*H) mm 800x333x554 800x333x554 800x333x554 845x363x702

Outdoor unit Packing (W*D*H) mm 920x390x615 920x390x615 920x390x615 965x395x765

Net/Gross weight Kg 28.5/31.4 28.5/31.4 36.9/39.6 49.7/51.2

Type R32 R32 R32 R32

Refrigerant GWP Kg 675 675 675 675
Charged quantity 0.65 0.65 1.25 1.6

Ceiling/Floor (Split) Additional Charge g/m 12 12 12 24

Refrigerant piping Liquid side/Gas side mm(inch) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ12.7(1/4"/1/2") Φ9.52/Φ15.9(3/8"/5/8")

lMeWnaOgxiF.tpihrtCieoofnrniagtlreorlantEpniRpaeebmleoPteort Error Alarm Port Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Optional Wired Central
m Combination 2L5eakage Detect Memory 2In5let Compensation Air Functio3n0 Cooling Use Function D5ra0in Pump Control Manag

Max. height difference m 10 10 20 25

Thermostat type Remote Control Remote Control Remote Control Remote Control

aOtpuerreation temper- Indoor (cooling/ heating) °C 16~32/0~30 16~32/0~30 16~32/0~30 16~32/0~30
Outdoor (cooling/heating) °C -15~50/-25~30 -15~50/-25~30 -15~50/-25~30 -15~50/-25~30

PRICE £ 628.00 748.00 946.00 1,395.00

Mi Points 9 12 18 24

Nominal Conditions: Cooling; indoor 27°C DB, 19°C WB, outdoor 35°C DB, 24°C WB. UK Conditions: Summer: indoor 21°C DB, 15°C WB, outdoor 27°C DB.
Nominal Conditions: Heating; indoor 20°C DB, outdoor 7°C DB, 6°C WB. Sound Pressure is measured 1.0m below the air-outlet at Nominal Conditions.

9

ULTIMATE COMFORT SERIES

Ultimate

Blanc (S

Elegant S-curved design Mission

Dual Filtration System

ELEGANT S-CURVED DESIGN DUAL PURIFICATION SYSTEM Cassette

A smart streamlined exterior, with S-curved design combines Double protection - dual filters remove dust and absorb
technology and style. The display dims automatically in low light harmful particles and bacteria, giving you cleaner, fresher air.
saving energy and reducing light display during sleep.
PURE COMFORT
FLASHCOOL TECHNOLOGY
Smart technology detects humidity levels and adjusts cool
The high frequency start-up system generates airflow to the desired level.
a strong flow of cool air in a very short time.
ENERGY SAVING R32 TECHNOLOGY Duct (Sp
WIDE ANGLE AIRFLOW
A highly efficient inverter system and iECO energy saving
The optimised air outlet design widens the airflow angle technology make this air conditioner very economical to run.
for optimum comfort.

10

ULTIMATE COMFORT SERIES

Indoor unit

Outdoor unit Remote control

e Comfort (Split)

Optional Intelligent Cool Bill Control Humidity Control Quiet Control Fresh Air Skin Moisturizing Bacteria & GA Stepless High Density
WiFi Control Dust Removal Comfort Technology Filter

Self Clean Cold Catalyst Follow Me 2-way Smart Reminder Weekly Timer Louver Position Refrigerant Auto Restart Frost Mi Fi Ready
Filter Draining Memory Leakage Detect Function Protection

INDOOR MT-09N8D6-I MT-12N8D6-I

Split) OUTDOOR MBT-09N8D6-O MBT-12N8D6-O
(Split)
Nominal Cooling Capacity (min-max) kW 2.6 (1.17 - 3.3) 3.5(1.38- 4.3)
e (Split)
plit) WiFi SupNeormCoinoal l Heating CFlaapshacity (miTnh-mreaex-D) imensional iEkCWO Mode Gear Ch3an.0ge(.91 “-D3i.a7m5o)nd-Edged” Fros4t.0 (1.07 - 4R.e4f)rigerant Self-diagnosis and
Control Cooling/Heating Airflow kW Casing Protection Leakage Detect Auto-protection
UK Total Cooling Capacity 4.07
3.15

Power supply (indoor power via outdoor) V-Hz-Ph 220-240, 50Hz/1Ph 220-240, 50Hz/1Ph

Cooling Current (min-max) A 2.94(0.35-4.78) 4.37(02.54h-7.2)

Follow Me HeatinSgwCeeutrrDerneta(mmsin-maHxi)gh Density Cold CatalysAt Self-cleaning 2.8(0.23-2w-a4y.32) Auto Restart 4.2144-(h0o.u5r-6Ti.m4)er Anti-cold
Filter Filter A Dr9aining Function 10 Air Function
Max. current

Outdoor Recommended Fuse Size A 16 16

Interconnecting/Indoor Power Wiring No. 5 Core 1.5mm 5 Core 1.5mm

Seasonal Efficiency SEER/Class W/W 8.2/A++ 7.4/A++

Indoor air flow (Hi/Mi/Lo) m3/h 500/370/240 550/480/420

Arctic Fox Remote BillICnodnotoror lsound pWreisFsi uCroentlreovlel (Hi/MTui/rbLo/MSoi)de HigdhBD(eAn) sity Cold Cata3l8ys/t29/20/1Fo9llow Me 2-wa3y 9/29/2S0m/2ar1t Reminder
Dimension (W*D*H) Filter Filter Draining
mm 886x188x315
886x188x315

Indoor unit Packing (W*D*H) mm 985x300x385 985x300x385

Net/Gross weight Kg 10.3/13.3 10.3/13.3

Smart Sleep Curve QuiOetuMtdoodoer air flSomwart Diagnosis “Diamond-Edged” Wemek3ly/hTimer Louver Positio1n980 Refrigerant Auto Restart1980 Frost
Casing dB(A) Memory 50 Leakage Detect Function 50 Protection
Outdoor sound pressure level

Dimension (W*D*H) mm 800x333x554 800x333x554

Outdoor unit Packing (W*D*H) mm 920x390x615 920x390x615

Net/Gross weight Kg 29.1/31.6 29.1/31.7

Type R32 R32

Refrigerant GWP Kg 675 675
Charged quantity 0.65 0.69

Additional Charge g/m 12 12

Liquid side/Gas side mm(inch) Φ6.35/Φ9.52(1/4"/3/8") Φ6.35/Φ9.52(1/4"/3/8")

Refrigerant piping lMenagx.threfrigerant pipe m 25 25

Max. height difference m 10 10

Optional 360˚TAhirermostaRtetmypoete Error Alarm Twin Refrigerant Louver PosRiteiomn oteFCreosnhtrAoilr Temperature ReAmntoi-cteolCdontroLol w Ambient Emergency Built-in Wired Ce
WiFi Control Flow Panel Enable Port IndPooortr (coolinCgo/mhbeinaattiinogn) Lea°kCage Detect Memory17~32/0I~nl3e0t Compensation A1ir7F~u3n2ct/io0n~30 Cooling Use Function Drain Pump Control M

Oatpuerreation temper- Outdoor (cooling/heating) °C -15~50/-25~30 -15~50/-25~30

PRICE £ 808.00 950.00

Mi Points 9 12

Nominal Conditions: Cooling; indoor 27°C DB, 19°C WB, outdoor 35°C DB, 24°C WB.
APdrejussstuarbeSUNleoKoSuSmwCntiaitodnctnhiaPcdlriCetEiosonRsnnauedsbmri:leteSiooiPutsneomsmr:tmeHeaEersra:ruotiirnrnedAgdol;ao1irnrm.0d2moP1oo°rbrCte2l0DoC°wBoCm,tT1hbDw5eiBni°naa,Citorio-uWontudBto,lWeootruira7tedtd°oNCCooorDmn2Bti7rn,o°a6l Cl°LCCeDoRaBWnek.dafBrigit.geioeDnraesnt.et ct
Optional Louver Position Fresh Air Temperature Anti-cold 2-way Timer Low Ambient
WiFi Control Memory Inlet Compensation Air Function Draining Cooling U

11

DUCT SERIES

(Split)

Optional Intelligent Cool Bill Control Humidity Control Quiet Control Fresh Air Skin Moisturizing Bacteria & GA Stepless High Density
WiFi Control Dust Removal Comfort Technology Filter

Cold Catalyst Follow Me 2-way Smart Reminder Weekly Timer Louver Position Refrigerant Auto Restart Frost
Filter Draining Memory Leakage Detect Function Protection

WiFi Super Cool Flash Three-Dimensional iECO Mode Gear Change “Diamond-Edged” Frost Refrigerant Self-diagnosis and
Control Cooling/Heating Airflow Casing Protection Leakage Detect Auto-protection

Follow Me Sweet Dreams High Density Cold Catalyst Self-cleaning 2-way Auto Restart 24h Anti-cold
Filter Filter Draining Function 24-hour Timer Air Function

Arctic Fox Remote Bill Control WiFi Control Turbo Mode High Density Cold Catalyst Follow Me 2-way Smart Reminder
Filter Filter Draining

Smart Sleep Curve Quiet Mode Smart Diagnosis “Diamond-Edged” Weekly Timer Louver Position Refrigerant Auto Restart Frost
Casing Memory Leakage Detect Function Protection

Optional 360˚ Air Remote Error Alarm Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Built-in Wired Central Control
WiFi Control Flow Panel Enable Port IndooPorrut nit Combination Leakage Detect Memory InletOutdoCoomrpuennsiattion Air Function Cooling Use Function Drain Pump
ControRl emMoatneagceomnetnrtol

Optional Adjustable Static Remote Error Alarm Port Twin Wired Control Refrigerant Louver Position Fresh Air Temperature Anti-cold 2-way Timer Low Ambient Emergency Central Control
WiFi Control Pressure Switch Enable Port Combination Leakage Detect Memory Inlet Compensation Air Function Draining Cooling Use Function Management

FLEXIBLE AIR INTAKE POSITION LED CHASSIS MOUNTED DISPLAY

Air inlet from back standard and from bottom optional. Built in display for easy trouble shooting and system

BUILT IN DRAIN PUMP information.

The built in drain pump can lift the condensate water up to 750mm. FRESH AIR INLET

t) MULTI CHANNEL AIR DISTRIBUTION Built in fresh air inlet to make a more comfortable
environment.

WOiFcTpithChioonaenatlnroulnneiEtlnsRaaebmailerorPtdeeoritsstuErrriiotbraAublatrlimeoPnofortgrCiovdmeTibwfsifnineaytirooenunLetcRaoekraformgigeoeDfrmaoentert ctttyLiopnueMveeesrmvP,ooeisrytirtsiyonmcouFrrleInntsliheetAri.r Temperature Anti-cold Low Ambient Emergency Optional Wired Central Control
FLEXIBLE CONTROL AND EASY MAINTENANCECompensation Air Function
Cooling Use Function Drain Pump Control Management

The electrical control box can be removed away from the unit
for easy maintenance access. Standard functional ports are
included such as Remote On/Off, Dry Contact Switch and
Alarm Signal Output.

12

DUCT SERIES MTIU-12FNXD0 MTIU-18FNXD0
INDOOR MTIU-24FNXD0
MOU-12FN8-QD0 MOU-18FN8-QD0
OUTDOOR MOU-24FN8-QD0 Mi Fi Ready
3.5 (0.62-4.40) 5.28(1.23-6.15)
Nominal Cooling Capacity (min-max) kW 3.8(0.62-4.98) 5.57(1.76-7.03) 7.03(2.20-8.21)
kW 7.62(2.43-8.65)
Nominal Heating Capacity (min-max) kW 4.17 5.77
W/W 6.1/A++ 6.5/A++ 7.78
UK Total Cooling Capacity W/W 6.1/A++
V- Ph-Hz 4/A+ 4/A+
Seasonal Efficiency SEER / Class V- Ph-Hz Power from Outdoor 220~240-1-50 4/A+
A 220~240-1-50 220~240-1-50
Seasonal Efficiency SCOP / Class A 220~240-1-50 220~240-1-50
A 4.7(1.0-7.7) 7.1(1.2-9.3) 9.5(2.1-12.4)
Power supply (Indoor ) A 4.5(2.3-8.2) 6.5(1.4-9.5) 8.9(2.2-12.5)
A 8.7
Power supply (Outdoor ) No. 10.0 13.5
m3/h Power from Outdoor 5* 5*
Cooling Current (min-max) dB(A) 16 16 20
mm 2 Core 1mm² Screened 2 Core 1mm² Screened
Heating Current (min-max) mm 4 Core 1mm² 1006/853/684 1248/1054/839
Kg 600/480/300 40/36/33 41/38/34
Max. input current mm 880x674x210 1100x774x249
m3/h 38/34/31 1070x725x270 1305x805x305
Recommended Fuse Size (Indoor ) dB(A) 700x450x200 25.6/31.4 31.5/38.9
mm 860x540x275 ODΦ25 ODΦ25
Recommended Fuse Size (Outdoor) mm 2100 2700
Kg 18/22 51 55
Interconnecting Wiring ODΦ25 800x333x554 845x363x702
Kg 2000 920x390x615 965x395x765
Indoor air flow (Hi/Mi/Lo) g/m 35.6/38.5 66.8/72.6
mm(inch) 51 R32 R32
Indoor sound pressure level (Hi/Mi/Lo) m 800x333x554 675 675
m 920x390x615 1.35 1.5
Dimension (WxDxH) °C 12 24
°C 34.5/37.3 Φ6.35/Φ12.7(1/4"/1/2") Φ9.52/Φ15.9(3/8"/5/8")
Indoor unit Packing (WxDxH) R32 30 50
675 20 25
Net/Gross weight 1.05 17~32/0~31 17~32/0~32
12 -15~50/-15~25 -15~50/-15~26
Drainage water pipe diameter
Φ6.35/Φ9.52(1/4"/3/8") 1,524.00 1,882.00
Outdoor air flow 25 18 24
10
Outdoor sound pressure level MTI-48FNXD0
17~32/0~30 MOU-48FN8-RD0
Dimension (WxDxH) -15~50/-15~24 14 (4.26-16.41)
16.1(3.7-18.13)
Outdoor unit Packing (WxDxH) 1,194.00
12 15.54
Net/Gross weight 6.1/A++

Type 4/A+
220~240-1-50
Refrigerant GWP
Charged quantity 380~415-3-50

Additional Charge 8.3(1.8-9.4)
6.8(1.65~10.22)
Liquid side/ Gas side
11.2
Refrigerant piping Max. pipe length 5*
16
Max. difference in level 2 Core 1mm² Screened
2400/2040/1680
Operating temperature Indoor (Cooling/Heating) 45/42/40
Outdoor (Cooling/Heating) 1200x874x300
1405x915x355
PRICE £ 47.6/55.8
ODΦ25
Mi Points 7500
59
INDOOR kW MTI-36FNXD0 952x415x1333 MTI-55FNXD0
OUTDOOR kW 1095x495x1480 MOU-55FN8-RD0
Nominal Cooling Capacity (min-max) kW MOU-36FN8-(Q/R)D0 106.7/119.9 16 (5.86-18.11)
Nominal Heating Capacity (min-max) W/W R32 18.2(4.69-20.52)
UK Total Cooling Capacity W/W 10.55(2.64-12.01) 675
Seasonal Efficiency SEER / Class V- Ph-Hz 11.14(2.93-13.19) 2.8 16.89
Seasonal Efficiency SCOP / Class 24 6.1/A++
Power supply (Indoor ) V- Ph-Hz 11.38 Φ9.52/Φ15.9(3/8"/5/8")
6.1/A++ 65 4/A+
Power supply (Outdoor ) A 30 220~240-1-50
A 4/A+ 17~32/0~34
Cooling Current (min-max) A 220~240-1-50 -15~50/-15~28 380~415-3-50
A 220~240-13-5-500| 380~415-
Heating Current (min-max) A 16.3(2.9-19.6)/ 7.2(1.2-8.2) 3,396.00 8.93(2-11)
No. 12.9(2.8-19.8)/ 5.5(1.2-8.3) 48 8.8(1.6-9.9)
Max. input current m3/h
dB(A) 21.5/10.0 14.0
Recommended Fuse Size (Indoor ) mm 5* 5*
mm 16
Recommended Fuse Size (Outdoor) Kg 32 | 16 2 Core 1mm² Screened
mm 2 Core 1mm² Screened 2600/2210/1820
Interconnecting Wiring m3/h 45/42/40
dB(A) 1400/1150/750 1200x874x300
Indoor air flow (Hi/Mi/Lo) mm 43/40/36 1405x915x355
mm 47.6/55.8
Indoor sound pressure level (Hi/Mi/Lo) Kg 1360x774x249 ODΦ25
1570x805x305 7500
Dimension (WxDxH) Kg 56
g/m 40.5/48.5 952x415x1333
Indoor unit Packing (WxDxH) mm(inch) ODΦ25 1095x495x1480
m 4000 111.3/124.3
Net/Gross weight m 56 R32
°C 675
Drainage water pipe diameter °C 946x410x810 2.95
1090x500x875 24
Outdoor air flow 66.8/72.6 | 81.5/87.0 Φ9.52/Φ15.9(3/8"/5/8")
65
Outdoor sound pressure level R32 30
675 17~32/0~35
Dimension (WxDxH) 2.4 -15~50/-15~29
24
Outdoor unit Packing (WxDxH) Φ9.52/Φ15.9(3/8"/5/8") 3,492.00 Nominal Conditions: Cooling; indoor
65 55 27°C DB, 19°C WB, outdoor 35°C
Net/Gross weight 30 DB, 24°C WB.
17~32/0~33 Nominal Conditions: Heating; indoor
Type -15~50/-15~27 20°C DB, outdoor 7°C DB, 6°C WB.
UK Conditions: Summer: indoor 21°C
Refrigerant GWP 2,660.00 DB, 15°C WB, outdoor 27°C DB.
Charged quantity 36 Sound Pressure is measured 1.5m
below the air-outlet at Nominal
Additional Charge Conditions.
*Option for power via Outdoor also
Liquid side/ Gas side available.

Refrigerant piping Max. pipe length 13

Max. difference in level

Operating temperature Indoor (Cooling/Heating)
Outdoor (Cooling/Heating)

PRICE £

Mi Points

COMPACT ROUND FLOW Mission (Split)
CASSETTE RANGE

Cassette (Split)
Duct (Split)

Ceiling/Floor (Split

360° AIRFLOW OUTLET

360° air outlet provides even airflow circulation to cool
or heat every corner of a room and keep a constant
temperature.

FRESH AIR INLET LOW AMBIENT COOLING

Benuvilitroinnmfreesnht.aOirpitn1i5ol3enmtamtlommotaokreaavamilaoUbrletlreacttoohmininfocrrteaabslee With built-in low ambient kit or specially designed
the fresh air effect. PCB, outdoor fan speed can be changed automatically
according to condenser temperature, even when the
750mm temperature is down to -15°C.

BUILT IN DRAIN PUMP LED FASCIA DISPLAY

The built in drain pump can lift the condensate Built in display for easy trouble shooting and system
water up to 750mm. information.
14

COMPACT ROUND FLOW Follow Me 2-way Smart Reminder
Arctic Fox Remote Bill Control WiFi Control Turbo Mode High Density Cold Catalyst Draining
CASSETTE RANGEFilter Filter

Mi Fi Ready

Smart Sleep Curve Quiet Mode Smart Diagnosis “Diamond-Edged” Weekly Timer Louver Position Refrigerant Auto Restart Frost
Casing Memory Leakage Detect Function Protection

Indoor unit Outdoor unit Remote control

Optional 360˚ Air Remote Error Alarm Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Built-in Wired Central Control
WiFi Control Flow Panel Enable Port Port Combination Leakage Detect Memory Inlet Compensation Air Function Cooling Use Function Drain Pump Control Management

INDOOR MCA3U-12FNXD0 MCA3-18FNXD0

OUTDOOR MOU-12HFN8-QD0 MOU-18FN8-QD0 

Nominal Cooling Capacity (min-max) kW 3.5 (0.62-4.40) 5.3 (0.79-6.15)

Nominal Heating Capacity (min-max) kW 4.1 (0.62-5.13) 5.6 (0.88-7.03)

Optional Adjustable Static Remote UKErTroortaAllaCromoPlionrgt CapaTcwiitny Wired Control RefrigeraknWt Louver Position Fresh4A.1ir7 Temperature Anti-cold 5.77 2-way Timer Low Ambient Emergency Central Control
WiFi Control Pressure Switch Enable PortSeasonal EfficiencCyoSmEbEinRa/tiColnass Leakage DWete/cWt Memory I6n.l1et/A++ Compensation Air Functio6n .3/A+D+raining Cooling Use Function Management

Seasonal Efficiency SCOP/Class W/W 4/A+ 4/A+

Power supply (Indoor ) V- Ph-Hz 220~240-1-50 220~240-1-50

Power supply (Outdoor ) V- Ph-Hz 220~240-1-50 220~240-1-50

Cooling Current (min-max) A 4.4(1.0-7.7) 7.5(1.2-10.9)

Heating Current (min-max) A 4.5(2.3-8.4) 6.8(1.38-11.50)

Max.Current A 8.7 10

Recommended Fuse Size (Indoor ) A 5 5*

Recommended Fuse Size (Outdoor) A 16 20

t) Interconnecting Wiring No. 4 Core 1mm² 2 Core 1mm² Screened

Indoor air flow (Hi/Mi/Lo) m3/h 650/530/450 660/550/490
Optional Remote Error Alarm Port Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Optional Wired Central Control
WiFi Control Enable Port IndoCoormsboinuantdionpreLsesaukaregeleDveetlec(tHi/MMie/mLoo)ry Inlet dB(A)Compensation Air3Fu8n/c3t4io/n31 Cooling Use Funct4io1n/38D/r3a4in Pump Control Management

Dimension (WxDxH) (body) mm 570x570x260 570x570x260

Packing (WxDxH)(body) mm 655x655x290 655x655x290

Indoor unit D(piamneenl)sion (WxDxH) mm 647x647x50 647x647x50
Packing (WxDxH)(panel) mm 715x715x123 715x715x123

Net/Gross weight (body) Kg 16/19 16.5/19

Net/Gross weight (panel) Kg 2.5/4.5 2.5/4.5

Drainage water pipe dia. mm ODΦ25 ODΦ25

Outdoor air flow m3/h 2000 2100

Outdoor sound pressure level dB(A) 51 51

Dimension (WxDxH) mm 800x333x554 800x333x554

Outdoor unit Packing (WxDxH) mm 920x390x615 920x390x615

Net/Gross weight Kg 34.5/37.3 35.6/38.5

Type R32 R32

Refrigerant GWP Kg 675 675
Charged quantity 1.05 1.35

Additional Charge g/m 12 12

Liquid side/ Gas side mm(inch) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ12.7(1/4”/1/2”)

Refrigerant piping Max. pipe length m 25 30

Max. height difference m 10 20

Oatpuerreating temper- Indoor (Cooling/Heating) °C 17~32/0~30 17~32/0~31
Outdoor (Cooling/Heating) °C -15~50/-15~24 -15~50/-15~25

PRICE £ 1,178.00 1,560.00

Mi Points 12 18

Nominal Conditions: Cooling; indoor 27°C DB, 19°C WB, outdoor 35°C DB, 24°C WB. *Option for power via Outdoor also available.
Nominal Conditions: Heating; indoor 20°C DB, outdoor 7°C DB, 6°C WB. *R32 Data & Availability to be confirmed. Data above based on R410a equipment.
UK Conditions: Summer: indoor 21°C DB, 15°C WB, outdoor 27°C DB.
Sound Pressure is measured 1.5m below the air-outlet at Nominal Conditions. 15

Mission (Split)

SUPER SLIM ROUND FLOW
CASSETTE RANGE

Cassette (Split)
Duct (Split)

Ceiling/Floor (Split

360° AIRFLOW OUTLET Horizontal flow

360° air outlet provides even airflow circulation Vertical flow
to cool or heat every corner of a room and keep
a constant temperature.

FRESH AIR INLET & DRAIN PUMP INDEPENDENT VANE CONTROL

Built in fresh air inlet to make a more comfortable The direction of each vane can be set
environment. Optional motor available to increase the fresh independently via the wired controller.
air effect. The built in drain pump has access panel for easy
removal /maintenance. 205mm Super slim

LED FASCIA DISPLAY SUPER SLIM BODY

Built in display for easy trouble shooting and system information. Super slim body starting from just 205mm.

16

SUPER SLIM ROUND FLOW CASSETTE RANGEArcticFoxRemote BillControl
WiFi Control Turbo Mode High Density Cold Catalyst Follow Me 2-way Smart Reminder
Filter Filter Draining

Smart Sleep Curve Quiet Mode Smart Diagnosis “Diamond-Edged” Weekly Timer Louver Position Refrigerant Auto Restart Frost
Casing Memory Leakage Detect Function Protection

Mi Fi Ready

Indoor unit Outdoor unit Remote control

Optional 360˚ Air Remote Error Alarm Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Built-in Wired Central Control
WiFi Control Flow Panel Enable Port Port Combination Leakage Detect Memory Inlet Compensation Air Function Cooling Use Function Drain Pump Control Management

INDOOR MCD-18FNXD0 MCD-24FNXD0 MCD-36FNXD0 MCD-48FNXD0 MCD-55FNXD0

OUTDOOR MOU-18FN8-QD0 MOU-24FN8-QD0 MOU-36FN8-(Q/R)D0 MOU-48FN8-RD0 MOU-55FN8-RD0

Nominal Cooling Capacity (min-max) kW 5.28(1.26-6.15) 7.03(2.23-8.21) 10.55(2.64-12.02) 14.0(4.76-16.12) 15.8(5.28-18.46)

Nominal Heating Capacity (min-max) kW 5.57(1.76-7.03) 7.62(2.43-8.65) 11.14(2.93-13.19) 16.1(3.93-17.59) 18.2(4.4~20.51)

UK Total Cooling Capacity kW 5.8 7.78 11.39 15.28 17.22
CToemmppeenr6saat.1utir/oeAn++AiAr nFtui-nccotlidon D2ra-winaiyn6g.1/A++ Timer
WSOiFepiatCisooonnnatlarollEAfPfdricejuisesstnuacrbeyleSSSwEtiEatctRhic/CElanRasebsmleoPteort Error Alarm PWor/t WComTbwinination Wire6d.C3o/nAt+ro+l Refrigerant LouMveer6mP.1oosr/yiAti+on+ Fresh Air LowCoAomlibnige6n.t1/AU+Esm+e eFrugnecntcioyn Central Control
Leakage Detect Inlet 4/A+ 4/A+ Management

Seasonal Efficiency SCOP/Class W/W 4/A+ 4/A+ 4/A+

Power supply (Indoor ) V- Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50

Power supply (Outdoor ) V- Ph-Hz 220~240-1-50 220~240-1-50 232800~~244105--13--5500| 380~415-3-50 380~415-3-50

Cooling Current (min-max) A 7.1(1.2-9.3) 9.5(2.1-12.4) 16.3(2.9-81.92.)6)/7.2(1.2- 8.3(1.8-9.26) 9.80(1.8-11)

Heating Current (min-max) A 6.5(1.4-9.5 8.9(2.2-12.5) 12.9(2.8-81.93.)8)/5.5(1.2- 8.2(1.56-8.83) 9.9(1.6~10.6)

Max.Current A 10.0 13.5 21.5/10 11.2 14.0

Recommended Fuse Size (Indoor ) A 5.0* 5.0* 5.0* 5.0* 5.0*
A 16 20.0 32 | 16 16 16
t) Recommended Fuse Size (Outdoor)

Interconnecting Wiring No. 2 Core 1mm² Screened 2 Core 1mm² Screened 2 Core 1mm² Screened 2 Core 1mm² Screened 2 Core 1mm² Screened
Optional Remote Error Alarm Port Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Optional Wired Central Control
WIniFdioCoorntaroirl flowEn(aHbi/leMPio/rLto) Combinatiomn 3L/ehakage Detect 10M3e6m/8or6y7/763 Inlet C1o3m7p8e/n1sa2t0io0n/10Ai3r 2Function 1C7o7o5li/n1g620/U1s4e3F8unction Dr1a7in1P5u/m1p568/1C3o8n1trol Mana1g9em70en/t1737/1537

Indoor sound pressure level (Hi/Mi/Lo) dB(A) 41/37/33 41/38/35 47/45/42 49/46/43 47/44/41

(Dbiomdeyn) sion (WxDxH) mm 840x840x205 840x840x205 840x840x245 840x840x287 840x840x287

Packing (WxDxH) (body) mm 900x900x225 900x900x225 900x900x265 900x900x292 900x900x292

Indoor unit D(piamneenl)sion (WxDxH) mm 950x950x55 950x950x55 950x950x55 950x950x55 950x950x55
P(paacnkeinl)g (WxDxH) mm 1035x1035x90 1035x1035x90 1035x1035x90 1035x1035x90 1035x1035x90

Net/Gross weight (body) Kg 21.4/25.1 23/27 27.5/31 29/32.7 29.7/33.4

N(peatn/eGlr)oss weight Kg 5/8 5/8 5/8 5/8 5/8

Drainage water pipe dia. mm ODΦ32 ODΦ32 ODΦ32 ODΦ32 ODΦ32

Outdoor air flow m3/h 2100 2700 4000 7500 7500

Outdoor sound pressure level dB(A) 51.0 55.0 56 59 56.0

Dimension (WxDxH) mm 800x333x554 845x363x702 946x410x810 952x415x1333 952x415x1333

Outdoor unit Packing (WxDxH) mm 920x390x615 965x395x765 1090x500x875 1095x495x1480 1095x495x1480

Net/Gross weight Kg 35.6/38.5 66.8/72.6 66.8/73.4 | 81.5/87.0 106.7/119.9 111.3/124.3

Type R32 R32 R32 R32 R32

Refrigerant GWP 675 675 675 675 675

Charged quantity Kg 1.35 1.5 2.4 2.8 2.95

Additional Charge g/m 12 24 24 24 24

Liquid side/ Gas side mm(inch) Φ6.35/Φ12.7(1/4"/1/2") Φ9.52/Φ15.9(3/8"/5/8") Φ9.52/Φ15.9(3/8"/5/8") Φ9.52/Φ15.9(3/8"/5/8") Φ9.52/Φ15.9(3/8"/5/8")

Refrigerant piping Max. pipe length m 30 50 65 65 65

Max. height difference m 20 25 30 30 30

Oatpuerreating temper- HInedaotoinrg(C) ooling/ °C 17~32/0~32 17~32/0~33 17~32/0~34 17~32/0~35 17~32/0~36
OHueatdtionogr) (Cooling/ °C -15~50/-15~26 -15~50/-15~27 -15~50/-15~28 -15~50/-15~29 -15~50/-15~30

PRICE £ 1,710.00 1,986.00 2,498.00 3,238.00 3,560.00

Mi Points 18 24 36 48 55

Nominal Conditions: Cooling; indoor 27°C DB, 19°C WB, outdoor 35°C DB, 24°C WB. UK Conditions: Summer: indoor 21°C DB, 15°C WB, outdoor 27°C DB.
Nominal Conditions: Heating; indoor 20°C DB, outdoor 7°C DB, 6°C WB. Sound Pressure is measured 1.5m below the air-outlet at Nominal Conditions.
*Option for power via Outdoor also available.
17

CEILING AND FLOOR RANGE Cassette
Duct (Sp

Ceiling/

Drop ceiling

3D AIR FLOW horizontal andAvierrtiOcaul stwliengt function The unitVcEaRnTICbAeL OinRsHtaOlRleIZdONeTitAhLeINr ShToALriLzAoTInOtNally on
the ceilinThge uonrit cvaen rbteiicnsatalllyedavegrtaicianllysotr thhoreizowntaallylld. epending
The unit has auto
on your requirements and can even be installed at the corner
which supplies an even and comfortable airflow. of narrow ceilings.

tes a MANUAL OPERATION TIMER
).

Infrared DEF./FAN ALARM
signal
receiver

FRESH AIR INLET LED DISPLAY

Built in fresh air inlet to make a more comfortable Built in display for easy trouble shooting and system
environment. Optional motor available to increase information.
D MDV-D28Q1/N1-DthMDeVf-Dre36sQh1/aN1ir-DeMffDeVc-Dt.45Q1/N1-D MDV-D56Q1/N1-D MDV-D71

1-phase,220-240V,50Hz

2.8 3.6 4.5 5.6 7

3.2 18 4.0 5.0 6.3 8

41 41 48 48 6 Auto Swing & Wide-angle Airflow

e (Split) Optional

CEILING AND FLOOR RANGEWiFiControl Wired
360˚ Air Remote Error Alarm Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Built-in Control Central Control
Flow Panel Enable Port Port Combination Leakage Detect Memory Inlet Compensation Air Function Cooling Use Function Drain Pump Management

Mi Fi Ready

plit)

Optional Adjustable Static Remote Error Alarm Twin Wired Refrigerant Louver Position Fresh Air Temperature Anti-cold 2-way Timer Low Ambient Emergency
WiFi Control Pressure Switch Enable Port Port Combination Control Leakage Detect Memory Inlet Compensation Air Function Draining Cooling Use Function

Indoor unit Outdoor unit Remote control

/Floor (Split)

Optional Remote Error Alarm Twin Refrigerant Louver Position Fresh Air Temperature Anti-cold Low Ambient Emergency Wired Central Control
WiFi Control Enable Port Port Combination Leakage Detect Memory Inlet Compensation Air Function Cooling Use Function Control Management

INDOOR kW MUE-18FNXD0 MUE-24FNXD0 MUE-36FNXD0 MUE-48FNXD0 MUE-55FNXD0
OUTDOOR kW MOU-18FN8-QD0 MOU-24FN8-QD0 MOU-36FN8-(Q/R)D0 MOU-48FN8-RD0 MOU-55FN8-RD0
Nominal Cooling Capacity (min-max) kW 5.28 (1.29-6.20) 7.03 (2.20-8.21) 14.2 (4.96-16.4) 16.0 (5.28-18.46)
Nominal Heating Capacity (min-max) W/W 5.57 (1.76-7.03) 7.62 (2.43-8.65) 10.55(2.64-12.02) 16.1 (3.81-18.5) 18.2 (4.4-20.51)
UK Total Cooling Capacity W/W 11.14 (2.93-13.19)
Seasonal Efficiency SEER/Class V- Ph-Hz 5.82 7.77 15.43 17.44
Seasonal Efficiency SCOP/Class V- Ph-Hz 6.1/A++ 6.1/A++ 11.25 6.1/A++ 6.1/A++
Power supply (Indoor ) 6.3/A++ 4/A+ 4/A+
A 4/A+ 4/A+ 220~240-1-50 220~240-1-50
Power supply (Outdoor ) 220~240-1-50 220~240-1-50 4/A+ 232800~~244105--13--5500|
A 220~240-1-50 380~415-3-50
Cooling Current (min-max) A 220~240-1-50 220~240-1-50 232800~~244105--13--5500| 9.1(1.77-9.29)
A 16.3(2.9-189.2.6))/ 7.2(1.2- 10.5(1.9-10.3)
Heating Current (min-max) A 7.1(1.2-9.3) 9.5(2.1-12.4) 12.9(2.8-189..38))/ 5.5(1.2- 8.14(1.6-10.27)
No. 9.94(1.6-10.8)
Max.Current m3/h 6.5(1.4-9.5) 8.9(2.2-12.5) 21.5/10.0 11.2
dB(A) 5.0* 5.0* 14.0
Recommended Fuse Size (Indoor ) mm 10.0 13.5 32 | 16 5.0*
mm 5.0* 5.0* 32 | 16 2 Core 1mm² Screened 16
Recommended Fuse Size (Outdoor) Kg 16 20 2 Core 1mm² Screened 2329/1930/1417 2 Core 1mm² Screened
mm 2 Core 1mm² Screened 2 Core 1mm² Screened 50/43/47 2454/1834/1426
Interconnecting Wiring m3/h 902/786/677 1208/1066/853 2160/1844/1431 1650x675x235 49/45/41
dB(A) 40/35/31 48/43/38 50/48/45 1725x755x313 1650x675x235
Indoor air flow (Hi/Mi/Lo) mm 1068x675x235 1068x675x235 41.2/47.6 1725x755x313
mm 1145x755x313 1145x755x313 1650x675x235 ODΦ32 41.4/47.8
Indoor sound pressure level (Hi/Mi/Lo) Kg 26.6/31.8 26.8/31.9 1725x755x313 7500 ODΦ32
ODΦ32 ODΦ32 59 7500
Dimension (WxDxH) Kg 2100 2700 39/45 952x415x1333 56.0
g/m 51.0 55.0 ODΦ32 1095x495x1480 952x415x1333
Indoor unit Packing (WxDxH) mm(inch) 800x333x554 845x363x702 4000 106.7/119.9 1095x495x1480
m 920x390x615 965x395x765 R32 111.3/124.3
Net/Gross weight m 35.6/38.5 66.8/72.6 56 675 R32
R32 R32 946x410x810 2.8 675
Drainage water pipe dia. 675 675 1090x500x875 24 2.95
1.35 1.5 66.8/73.4 | 81.5/87.0 Φ9.52/Φ15.9(3/8”/5/8”) 24
Outdoor air flow 12 24 65 Φ9.52/Φ15.9(3/8”/5/8”)
Φ6.35/Φ12.7(1/4"/1/2") Φ9.52/Φ15.9(3/8”/5/8”) R32 30 65
Outdoor sound pressure level 50 675 30
30 25 2.4
Dimension (WxDxH) 20 24
Φ9.52/Φ15.9(3/8”/5/8”)
Outdoor unit Packing (WxDxH) 65
30
Net/Gross weight

Type

Refrigerant GWP
Charged quantity

Additional Charge

Liquid side/ Gas side

Refrigerant piping Max. pipe length

Max. height difference

aOtpuerreating temper- HInedaotoinrg(C) ooling/ °C 17~32/0~32 17~32/0~33 17~32/0~34 17~32/0~35 17~32/0~36
HOueatdtionogr) (Cooling/
°C -15~50/-15~26 -15~50/-15~27 -15~50/-15~28 -15~50/-15~29 -15~50/-15~30

PRICE £ 1,468.00 1,810.00 2,590.00 3,234.00 3,370.00
18 24 36 48 55
Mi Points

Nominal Conditions: Cooling; indoor 27°C DB, 19°C WB, outdoor 35°C DB, 24°C WB. UK Conditions: Summer: indoor 21°C DB, 15°C WB, outdoor 27°C DB.
Nominal Conditions: Heating; indoor 20°C DB, outdoor 7°C DB, 6°C WB. Sound Pressure is measured 1.5m below the air-outlet at Nominal Conditions.
*Option for power via Outdoor also available.
19

SPLIT SYSTEMS QUICK REFERENCE GUIDE

TYPE CODE COOLING HEATING PIPE SIZES MAX PIPE
kW (Min-Max) kW (Min-Max) LENGTH (M)
MA
Blanc Wall Mount Series 09
12
Mission Wall Mount Series 18 2.6 (1.02 - 3.22) 3.0 (0.82 - 3.37) 1/4” & 3/8” 25
24 3.5(1.08 - 4.10) 4.0 (1.08 - 4.22) 1/4” & 3/8” 25
Ultimate Wall Mount Series MB 5.3 (1.91 - 6.14) 5.7 (1.4 - 6.91) 1/4” & 1/2” 30
Compact Roundflow Cassette 09 7.0 (2.65 – 8.25) 7.6 (2.91 - 8.53) 3/8” & 5/8” 50
Compact Roundflow Cassette Twin 12
Super Slim Roundflow Cassette 18 2.6 (1.02 - 3.3) 3.0 (0.82 - 3.75) 1/4” & 3/8” 25
24 3.5(1.37 - 4.5) 4.0 (1.06 - 4.9) 1/4” & 3/8” 25
MT 5.3 (1.96 - 6.21) 5.7 (1.96 - 6.97) 1/4” & 1/2 30
09 7.0 (2.11 - 8.44) 7.6 (1.55 - 9.43) 3/8” & 5/8” 50
12
MCA 2.6 (1.17 - 3.3) 3.0 (.91 - 3.75) 1/4” & 3/8” 25
12 3.0 (.91 - 3.75) 4.0 (1.07 - 4.4) 1/4” & 3/8” 25
18
MCA 3.5 (0.62-4.40) 4.1 (0.62-5.13) 1/4” & 3/8” 25
5.3 (0.79-6.15) 5.6 (0.88-7.03) 1/4” & 1/2” 30
18+18
10.55(2.64-12.02) 11.14(2.93-13.19) 1/4” & 1/2” In / 3/8” & 5/8” Out 65
MCD
18 5.28(1.26-6.15) 5.57(1.76-7.03) 1/4” & 1/2” 30
24 7.03(2.23-8.21) 7.62(2.43-8.65) 3/8” & 5/8” 50
36 10.55(2.64-12.02) 11.14(2.93-13.19) 3/8” & 5/8” 65
48 14.0(4.76-16.12) 16.1(3.93-17.59) 3/8” & 5/8” 65
55 15.8(5.28-18.46) 18.2(4.4-20.51) 3/8” & 5/8” 65
MCD
Super Slim Roundflow Cassette Twin 18+18 10.55(2.64-12.02) 11.14(2.93-13.19) 1/4” & 1/2” In / 3/8” & 5/8” Out 65
Ceiling / Floor 24+24 14.0(4.76-16.12) 16.1(3.93-17.59) 3/8” & 5/8” 65
30+30 15.8(5.28-18.46) 18.2(4.4-20.51) 3/8” & 5/8” 65
MUE
18 5.28 (1.29-6.20) 5.57 (1.76-7.03) 1/4” & 1/2” 30
24 7.03 (2.20-8.21) 7.62 (2.43-8.65) 3/8” & 5/8” 50
36 10.55(2.64-12.02) 11.14 (2.93-13.19) 3/8” & 5/8” 65
48 14.2 (4.96-16.4) 16.1 (3.81-18.5) 3/8” & 5/8” 65
55 16.0 (5.28-18.46) 18.2 (4.4-20.51) 3/8” & 5/8” 65
MUE
Ceiling / Floor Twin 18+18 10.55(2.64-12.02) 11.14 (2.93-13.19) 1/4” & 1/2” In / 3/8” & 5/8” Out 65
Ducted 24+24 14.2 (4.96-16.4) 16.1 (3.81-18.5) 3/8” & 5/8” 65
30+30 16.0 (5.28-18.46) 18.2 (4.4-20.51) 3/8” & 5/8” 65
MTI
12 3.5 (0.62-4.40) 3.8(0.62-4.98) 1/4” & 3/8” 25
18 5.28(1.23-6.15) 5.57(1.76-7.03) 1/4” & 1/2” 30
24 7.03(2.20-8.21) 7.62(2.43-8.65) 3/8” & 5/8” 50
36 10.55(2.64-12.01) 11.14(2.93-13.19) 3/8” & 5/8” 65
48 14 (4.26-16.41) 16.1(3.7-18.13) 3/8” & 5/8” 65
55 16 (5.86-18.11) 18.2(4.69-20.52) 3/8” & 5/8” 65
MTI
Ducted Twin 18+18 65
24+24 65
30+30 10.55(2.64-12.01) 11.14(2.93-13.19) 1/4” & 1/2” In / 3/8” & 5/8” Out 65
14 (4.26-16.41) 16.1(3.7-18.13) 3/8” & 5/8”
16 (5.86-18.11) 18.2(4.69-20.52) 3/8” & 5/8”

20 * 4 Core Option Available
** Indoor Power Option From Outdoor Available

MAX PIPE CHARGE INTERCONNECTING POWER SUPPLY MI-PRO CONTRIBUTION
HEIGHT (M) g/M CABLE
POWER TO Ph In (A) Out (A) LIST PRICE Mi Points RPefaryigmeernatnt

10 12 5 Core* 1.5mm² Outdoor 1 N/A 16 £530.00 9 £10
1 N/A 16 £610.00 12 £10
10 12 5 Core* 1.5mm² Outdoor 1 N/A 16 £900.00 18 £10
1 N/A 20 £1,310.00 24 £35
20 12 5 Core* 1.5mm² Outdoor
1 N/A 16
25 24 5 Core* 2.5mm² Outdoor 1 N/A 16
1 N/A 16
10 12 5 Core* 1.5mm² Outdoor 1 N/A 20 £628.00 9 £10
£748.00 12 £10
10 12 5 Core* 1.5mm² Outdoor 1 N/A 16 £946.00 18 £10
1 N/A 16 £1,395.00 24 £35
20 12 5 Core* 1.5mm² Outdoor
1 N/A 16
25 24 5 Core* 2.5mm² Outdoor 1 5 16

10 12 5 Core* 1.5mm² Outdoor £808.00 9 £10
£950.00 12 £10
10 12 5 Core* 1.5mm² Outdoor

10 12 4 core 1.5mm² Outdoor £1,178.00 12 £10
£1,560.00 18 £10
20 12 2 Core 1mm² Both**

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £2,807.00 36 £46

20 12 2 Core 1mm² Both** 1 5 16 £1,710.00 18 £10

25 24 2 Core 1mm² Both** 1 5 20 £1,986.00 24 £35

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £2,498.00 36 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,238.00 48 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,560.00 55 £46

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £3,106.00 36 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,738.00 48 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,873.00 55 £46

20 12 2 Core 1mm² Both** 1 5 16 £1,468.00 18 £10

25 24 2 Core 1mm² Both** 1 5 20 £1,810.00 24 £35

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £2,590.00 36 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,234.00 48 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,370.00 55 £46

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £2,623.00 36 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,385.00 48 £46

30 24 2 Core 1mm² Both** 3 5 16 £4,057.00 55 £46

10 12 4 Core 1mm² Outdoor 1 N/A 16 £1,194.00 12 £10

20 12 2 Core 1mm² Both** 1 5 16 £1,524.00 18 £10

25 24 2 Core 1mm² Both** 1 5 20 £1,882.00 24 £35

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £2,660.00 36 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,396.00 48 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,492.00 55 £46

30 24 2 Core 1mm² Both** 1|3 5 32 | 16 £2,735.00 36 £46

30 24 2 Core 1mm² Both** 3 5 16 £3,529.00 48 £46

30 24 2 Core 1mm² Both** 3 5 16 £4,197.00 55 £46

21

FREE MATCH
MULTI SERIES

FLEXIBLE INSTALLATION

One outdoor unit can be connected with up to 5 indoor units. Each indoor unit can be individually controlled.
Indoor units do not need to be installed at the same time, which enables system expansion, depending on the
user’s needs.

DEDICATED INDOOR UNITS

The Free Match range is the ideal solution for efficient
2, 3, 4 or 5-zone air conditioning with a single outdoor
unit. On a single system it is possible to connect a
range of different indoors with varying capacities. All
indoor units can be individually controlled and pipe
lengths of up 80 meters can be accommodated.

22

FREE MATCH OUTDOOR UNITS

Mi Fi Ready

5.3kW 7.9kW 10.6 kW, 12.3 kW

OUTDOOR M2O-18FN8-Q M30-27FN8-Q M4O-36FN8-Q M5O-42FN8-Q
5.3 (1.4 - 6.34) 7.9 (1.58 - 8.69)
Nominal Cooling Capacity (min-max) kW 5.6 (1.54 - 6.66) 8.2 (1.58 - 8.69) 10.6 (1.59 - 13.78) 12.3 (1.66 - 14)
kW
Nominal Heating Capacity (min-max) m3/h 2200 2700 11.1 (1.8 - 14.4) 12.3 (1.66 - 14.94)
m3/h 53 56
Outdoor air flow w/w 4000 3850
w/w 6.1/A+ 6.1/A++
Outdoor sound pressure level V-Hz 4/A 4/A 60 58

Seasonal Efficiency SEER/Class A 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph 6.2/A++ 6.1/A++
mm 7.1(0.7-9.27) 10.6(0.9-13.5)
Seasonal Efficiency SCOP/Class mm 6.1(1.4-7.74) 10.0(1.4-12.5) 3.8/A 3.8/A
Kg 12 15
Power supply (Outdoor) 16 16 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph
Kg 800x333x554 845x363x702
Cooling Current (min-max) g/m 920x390x615 965x395x755 15.0(1.5-18.5) 18.9(1.2-20.0)
36/39 53/56.5
Heating Current (min-max) R32 R32 12.1(2.1-18.4) 13.5(2.2-17.6)
675 675
Max. Current 1.3 1.57 21.5 22
12 12
Recommended Fuse Size (Outdoor) 25 25
(16/.345” && 93./582” ((xx22))) (16/.345” && 93./582” ((xx33)))
Dimension (WxDxH) 946x410x810 946x410x810
40 60
Packing (WxDxH) 1090x500x875 1090x500x875
25 30
Net/Gross weight 68.8/75.6 73.3/80.4
15 15
Type R32 R32
10 10
Refrigerant GWP Remote Control 675 675
Charged quantity Remote Control -15~50/-15~24
-15~50/-15~24 2.1 2.4
1,412.00
Additional Charge 992.00 27 12 (1/4”) 24 (3/8”) 12 (1/4”) 24 (3/8”)
18
Lsiidqeuid side/ Gas mm(inch) (61./345”&&((xx1414/)2)2&&.”79((3xx./1158))2)” (x3) (61./345”&&((xx1515/)2)2&&.”79((3xx./1158))2)” (x4)
(x3) (x4)

(MAall)x. pipe length m 80 80
(MPaexr ipnidpoeolre)ngth
pRiepfirniggerant m 35 35
°C
tMoaoxu. thdeoiogrht indoor 15 15

Mtwaexe.nhienigdhotobrse- 10 10

Thermostat type Remote Control Remote Control
-15~50/-15~24 -15~50/-15~24
Outdoor (Cooling/Heating)
2,210.00 2,306.00
PRICE £ 36 42

Mi Points

23

FREE MATCH INDOOR UNITS

HIGH WALL

INDOOR MA-09NXD0-I MA-12NXD0-I MA-18NXD0-I MA-24NXD0-I
2.6 (1.02 - 3.22) 3.5(1.08 - 4.10) 5.3 (1.91 - 6.14) 7.0 (2.65 - 8.25)
Nominal Cooling Capacity (min-max) kW 3.0 (0.82 - 3.37) 4.0 (1.08 - 4.22) 5.7 (1.4 - 6.91) 7.6 (2.91 - 8.53)
kW
Nominal Heating Capacity (min-max) kW 3.06 3.94 5.91 7.4
No. 4 Core 1.5mm 4 Core 1.5mm 4 Core 1.5mm 4 Core 1.5mm
UK Total Cooling Capacity V-Hz-Ph
m3/h Via Outdoor Via Outdoor Via Outdoor Via Outdoor
Interconnecting Wiring dB(A) 520/460/340 600/500/380 860/690/560 1050/860/700
mm
Power Supply mm 36/30/26/21 38/34/28/22 43/36/30/22 47/40/33/22
Kg
Indoor air flow (Hi/Mi/Lo) 805x205x285 805x205x285 958x223x302 1038x235x325
mm(inch) 870x285x360 870x285x360 1035x305x380 1120x405x330
ILnod/oSoi)r sound pressure level (Hi/Mi/ °C
7.9/10.3 7.9/10.3 10.3/13.3 12.8/16.2
Dimension (WxDxH) Remote Control Remote Control Remote Control Remote Control

Packing (WxDxH) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ12.7(1/4”/1/2”) Φ9.52/Φ15.9(3/8”/5/8”)

Net/Gross weight 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30

Thermostat type 196.00 222.00 292.00 330.00

pRiepfirniggerant Lsiidqeuid side/ Gas

Indoor (Cooling/Heating)

PRICE £

COMPACT CASSETTE kW MCA3L-09FNXDO MCA3U-12FNXDO MCA3U-18FNXC8
kW 2.6 (1.03 - 3.2) 3.5 (0.62-4.40) 5.3 (0.79-6.15)
INDOOR kW 3.0 (0.82 - 3.4) 4.1 (0.62-5.13) 5.6 (0.88-7.03)
Nominal Cooling Capacity (min-max) V-Hz-Ph 4.17 5.77
Nominal Heating Capacity (min-max) No. 3.06 Via Outdoor Via Outdoor
UK Total Cooling Capacity m3/h Via Outdoor 4 Core 1.5mm 4 Core 1.5mm
Power Supply dB(A) 4 Core 1.5mm 617/504/415 680/560/500
Interconnecting Wiring mm 580/500/450 37/34/31 44/38/33
Indoor air flow (Hi/Mi/Lo) mm 35/33/31 570x570x260 570x570x260
Indoor sound pressure level (Hi/Mi/Lo) Kg 570x570x260 655x655x290 655x655x290
Dimension (WxDxH) (body) mm 655x655x290 16.2/21.4 16.2/21.4
Packing (WxDxH) (body) mm 14.5/17.3 647x647x50 647x647x50
Net/Gross weight (body) Kg 647x647x50 715x715x123 715x715x123
Dimension (WxDxH) (panel) 715x715x123 2.5/4.5 2.5/4.5
Packing (WxDxH) (panel) Remote Control Remote Control
Net/Gross weight (panel) 2.5/4.5
Thermostat type Remote Control
Refrigerant piping Lsiidqeuid side/ Gas
Indoor (Cooling/Heating) mm(inch) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ12.7(1/4”/1/2”)

PRICE £ °C 17~32/0~30 17~32/0~30 17~32/0~30

600.00 610.00 630.00

DUCTED kW MTIU-09FNXD0 MTIU-12FNXD0 MTIU-18FNXD0
kW 2.6 (1.03 - 3.2) 3.5 (0.62-4.40) 5.3 (0.79-6.15)
INDOOR kW 3.0 (0.82 - 3.4) 3.8(0.62-4.98) 5.7(0.88-7.03)
Nominal Cooling Capacity (min-max) V-Hz-Ph
Nominal Heating Capacity (min-max) No. 3.06 4.17 5.77
UK Total Cooling Capacity m3/h Via Outdoor Via Outdoor Via Outdoor
Power Supply dB(A) 4 Core 1.5mm 4 Core 1.5mm 4 Core 1.5mm
Interconnecting Wiring mm 580/500/450 650/530/450 800/650/500
Indoor air flow (Hi/Mi/Lo) mm 32/28/26 38/35/32 42/38/36
Indoor sound pressure level (Hi/Mi/Lo) Kg 700x635x210 700x635x210 700x635x210
Dimension (WxDxH) 915x655x290 915x655x290 915x655x290
Packing (WxDxH) mm(inch) 18.5/23.1 18.5/23.1 23.0/29.0
Net/Gross weight °C Remote Control Remote Control Remote Control
Thermostat type Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ9.52(1/4”/3/8”) Φ6.35/Φ12.7(1/4”/1/2”)
Refrigerant piping Refrigerant 17~32/0~30 17~32/0~30 17~32/0~30
Indoor (Cooling/Heating)
422.00 470.00 542.00
PRICE £

*Data & Availability to be confirmed.

24

FREE MATCH INDOOR UNITS

CONSOLE kW MFAU-09FNXD0 MFAU-12FNXD0 MFAU-18FNXD0
kW 2.6 (1.03 - 3.2) 3.5(1.08 - 4.1) 5.3 (1.8 - 6.1)
INDOOR kW 3.0 (0.82 - 3.4) 4.0 (0.88 - 4.2) 5.7 (1.4 - 6.7)
Nominal Cooling Capacity (min-max) V-Hz-Ph 5.73
Nominal Heating Capacity (min-max) No. 3.06 3.85 Via Outdoor
UK Total Cooling Capacity m3/h Via Outdoor Via Outdoor 4 Core 1.5mm
Power Supply dB(A) 4 Core 1.5mm 4 Core 1.5mm 740/700/640
Interconnecting Wiring mm 550/470/360 550/470/360 48/42/38
Indoor air flow (Hi/Mi/Lo) mm 45/40/35 47/41/35 700x210x600
Indoor sound pressure level (Hi/Mi/Lo) Kg 700x210x600 700x210x600 810x305x710
Dimension (WxDxH) 810x305x710 810x305x710 15 / 20
Packing (WxDxH) mm(inch) 13.5 / 18 Remote Control
Net/Gross weight °C Remote Control 15 / 20
Thermostat type Φ6.35/Φ9.52(1/4”/3/8”) Remote Control Φ6.35/Φ12.7(1/4”/1/2”)
Refrigerant piping Refrigerant 17~32/0~30 Φ6.35/Φ9.52(1/4”/3/8”) 17~32/0~30
Indoor (Cooling/Heating) 17~32/0~30
350.00 408.00
PRICE £ 374.00

*Data & Availability to be confirmed.

COMBINATION TABLES

M2O-18FN8-Q Two Unit M3O-27FN8-Q Two Unit Three Unit
9+9 9+9 9+9+9
One Unit 9+12 One Unit 9+12 9+9+12
9 9+18 9 9+18 9+9+18
12 12
18 12+12 18 12+12 9+12+12
12+18 9+12+18
18+18 12+12+12

M4O-36FN8-Q Two Unit Three Unit Four Unit
12+12
One Unit 9+9 12+18 9+9+9 9+12+24 9+9+9+9 9+12+12+12
9 9+12 12+24
12 9+18 12+24 9+9+12 9+18+18 9+9+9+12 9+12+12+18
18 9+24
24 9+9+18 12+12+12 9+9+9+18 12+12+12+12

9+9+24 12+12+18 9+9+12+12 12+12+12+18

9+12+12 12+12+24 9+9+12+18

9+12+18 12+18+18

M5O-42FN8-Q Two Unit Three Unit Four Unit Five Unit
12+12
One Unit 9+9 12+18 9+9+9 9+12+18 9+9+9+9 9+9+12+24 9+9+9+9+9 9+9+12+12+12
9 9+12 12+24
12 9+18 18+18 9+9+12 9+18+18 9+9+9+12 9+12+12+12 9+9+9+9+12 9+12+12+12+12
18 9+24
24 9+9+18 12+12+12 9+9+9+18 9+12+12+18 9+9+9+9+18 9+12+12+12+18

9+9+24 12+12+18 9+9+9+24 12+12+12+12 9+9+9+12+12 12+12+12+12+12

9+12+12 12+18+18 9+9+12+12 12+12+12+18 9+9+9+12+18

9+12+24 12+12+24 9+9+12+18

25

FREE MATCH MULTI
QUICK REFERENCE GUIDE

TYPE CODE COOLING HEATING PIPE SIZES MAX PIPE
kW (Min-Max) kW (Min-Max) LENGTH (M)

Free Range Outdoor 5.6 (1.54 - 6.66)
8.2 (1.58 - 8.69)
18 5.3 (1.4 - 6.34) 11.1 (1.8 - 14.4) 1/4” & 3/8” (x2) 40
12.3 (1.66 - 14.94) 1/4” & 3/8” (x3) 60
27 7.9 (1.58 - 8.69) 1/4” (x4) & 3/8” (x3) & 1/2” (x1) 80
3.0 (0.82 - 3.37) 1/4” (x5) & 3/8” (x4) & 1/2” (x1) 80
36 10.6 (1.59 - 13.78) 4.0 (0.08 - 4.22)
5.7 (1.4 - 6.91)
42 12.3 (1.66 - 14) 7.6 (2.91 – 8.53)

Free Range High Wall MA 3.0 (0.82 - 3.4)
4.1 (0.62-5.13)
9 2.6 (1.02 - 3.22) 5.6 (0.88-7.03) 1/4” & 3/8” 25 - 35*
1/4” & 3/8” 25 - 35*
12 3.5(1.08 - 4.10) 3.0 (0.82 - 3.4) 1/4” & 1/2” 25 - 35*
3.8(0.62-4.98) 3/8” 5/8” 25 - 35*
18 5.3 (1.91 - 6.14) 5.7(0.88-7.03)

24 7.0 (2.65 – 8.25) 3.0 (0.82 - 3.4)
4.0 (0.88 - 4.2)
Free Range Compact Cassette MCA 5.7 (1.4 - 6.7)

9 2.6 (1.03 - 3.2) 1/4” & 3/8” 25 - 35*
1/4” & 3/8” 25 - 35*
12 3.5 (0.62-4.40) 1/4” & 1/2” 25 - 35*

18 5.3 (0.79-6.15)

Free Range Ducted MTI

9 2.6 (1.03 - 3.2) 1/4” & 3/8” 25 - 35*
1/4” & 3/8” 25 - 35*
12 3.5 (0.62-4.40) 1/4” & 1/2” 25 - 35*

18 5.3 (0.79-6.15)

Free Floor Mount MFA

9 2.6 (1.03 - 3.2) 1/4” & 3/8” 25 - 35*
1/4” & 3/8” 25 - 35*
12 3.5(1.08 - 4.1) 1/4” & 1/2” 25 - 35*

18 5.3 (1.8 - 6.1)
*Max pipe length varies depending on outdoor/indoor combination - see manual for full details.

26

POWER SUPPLY MI-PRO CONTRIBUTION
Ph Fuse (A)
MAX PIPE CHARGE INTERCONNECTING POWER TO LIST PRICE RPefaryigmeernatnt
HEIGHT (M) g/M CABLE
Mi Points

10 See Indoor See Indoor Outdoor 1 16 £992.00 18 £10
10 See Indoor See Indoor Outdoor 1 16 £1,412.00 27 £12
10 See Indoor See Indoor Outdoor 1 25 £2,210.00 36 £17
10 See Indoor See Indoor Outdoor 1 25 £2,306.00 42 £21

10 12 4 Core 1.5mm Outdoor 1 N/A £196.00 See Outdoor
See Outdoor
10 12 4 Core 1.5mm Outdoor 1 N/A £222.00 See Outdoor
See Outdoor
10 12 4 Core 1.5mm Outdoor 1 N/A £292.00

10 24 4 Core 1.5mm Outdoor 1 N/A £330.00

10 12 4 Core 1.5mm Outdoor 1 N/A £600.00 See Outdoor
See Outdoor
10 12 4 Core 1.5mm Outdoor 1 N/A £610.00 See Outdoor

10 12 4 Core 1.5mm Outdoor 1 N/A £630.00

10 12 4 Core 1.5mm Outdoor 1 N/A £422.00 See Outdoor
See Outdoor
10 12 4 Core 1.5mm Outdoor 1 N/A £470.00 See Outdoor

10 12 4 Core 1.5mm Outdoor 1 N/A £542.00

10 12 4 Core 1.5mm Outdoor 1 N/A £350.00 See Outdoor
See Outdoor
10 12 4 Core 1.5mm Outdoor 1 N/A £374.00 See Outdoor

10 12 4 Core 1.5mm Outdoor 1 N/A £408.00

27

Mi Fi Midea Air App

COLOUR-CODED SMARTS

Unlike a lot of air conditioning controls that use confusing icons, Midea Air App is colour-coded for simplicity.
There’s blue for cooling, red for heating, yellow for fan-only operation and green for our set and forget auto function.

HEATING COOLING TAKE A CLOSER LOOK
Unit Location
Get your conditions all cosy before you Nobody likes to work or live in an oven. Name the unit location/System No.
arrive at work or home. Keep your cool from the moment you walk System status
in the door. Outdoor Temperature/Indoor Temperature/
Humidity
FAN ONLY AUTO
Circle of operation
Sometimes you only need some air Automatically cool or heat your home Set Temp/Mode/Fan Speed
circulation to get comfortable. The great or place of work with the set and forget User Set Temperature
thing with this option is it saves on your auto function. Rotate from 16 to 30°C
power bill too.
Power Button
INFORMATIVE CONTROL Turn air conditioner On/Off
Mode
FULL ZONE CONTROL Auto/Cool/Heat/Dry/Fan Only
Fan Speed
Add Device Select fan speed from 0 to 100%
Add and share devices direct
from your home screen SYSTEM CHECKS
Full Zone Control AT HOME OR AWAY
Create, View & Edit zones in
your app. Control each zone TEST UP TO 105 ITEMS REMOTELY
individually
Online or off line Remotely check connected equipment or share
Check the connection of the system status with a trained technician should
Systems saved on your app your device indicate a system abnormality. Remote
scanning and equipment diagnostics at the touch
SET AND FORGET TIMER of a button.
You can check up to 105 test items of every
Timer connected system to ensure that equipment is
Control ON/OFF timer performing to the standards you would expect
Set time indicator* from Midea. In the unlikely event of equipment
Displays the days you want to turn malfunction your first visit to site could be armed
ON or OFF your air conditioner with the required spare part already diagnosed
Timer increments in minutes remotely. Saving time on equipment diagnostics
Scroll up or down to set the and end user inconvenience
minutes
Timer increments in hours
Scroll up or down to set the hours
from 0 to 24:00 hours
Timer set button
Press to accept the timer

28

VRF OUTDOOR

MINI VRF FULL DC INVERTER
V4 HEAT RECOVERY
V6 HEAT PUMP
CONTROLLERS
BRANCH JOINTS
MODE SWITCH (MS) BOX

29

MINI VRF FULL DC INVERTER

WIDE APPLICATION RANGE

WIDE CAPACITY RANGE

The outdoor units’ capacity range from 7.2kW to 45kW which is ideal for small offices, villas, apartment and shops,
making it perfect for commercial and residential application.

7.2kW(1.5~8kW), 9.0kW(2~10kW) 12.3kW, 14kW, 15.5kW, 17.5kW 20kW, 22.4kW, 26kW, 40kW, 45kW

WIDE RANGE OF INDOOR UNITS WIDE OPERATION RANGE

Midea provides 12 ranges and more than 100 models of VRF Mini VRF Series operates stably under extreme
indoor units. These have been proven to meet a wide range of conditions, ranging from minus 15°C to 48°C.
applications including Hotels, Hospitals, Office Blocks, Airports
and Sports Stadiums.

-15°C 48°C

Cooling Mode

-15°C 27°C

Heating Mode

LONG PIPING LENGTH

The Mini VRF provides a total piping length possibility of 250m, a maximum height difference between outdoor and indoor units
of 30m. The height difference between indoor units can be up to 8m. These generous allowances facilitate an extensive array of
system designs.

PERMITTED VALUE(M) 7.2/9kW 12.3/14/ 20/22.4/ 40/45kW
100 15.5/17.5kW 26kW 250
45 100
Total piping length (Actual) 50 100 120 120

Level difference between IDU and ODU is 30m Piping length (LLo)ngest piping Actual length 20 60 60 40
Level difference between IDUs is 8m Equivalent length
The IDU to the nearest 20 70 70 20
branch joint is 15m 30 30
The first branch joint to the Etbhrqeaunifvacahrtlehjoneitsntpt)IipDiUngtoletnhgethfir(sftroinmdoor 8 20 20 8
farthest IDU is 40m
The longest piping length is 120m eLenvceel differ- LIbDeeUvtwe~leOdeDinfUference Outdoor unit up 20 20
Outddooowrnunit 30 30
88
Level difference between IDU~IDU

1. Total pipe length is equal to all the liquid pipe or all the gas pipe length.
2. When the total equivalent pipe length of liquid side plus gas side is more than 90m, it needs to meet

the specific conditions according to the installation part of the technical manual.

30

MINI VRF FULL DC INVERTER

EASY INSTALLATION AND SERVICE

EASY INSTALLATION

No special area is required for outdoor units. All outdoor
units can be transported by elevator, which greatly simplifies
installation and reduces time and labour.
The Mini VRF system’s indoor and outdoor units are almost
as easy to install as residential air conditioning systems,
making them ideal for small offices and shops.

SPACE SAVING DESIGN

The Mini VRF units are slimmer and more compact, resulting in significant savings in installation space.
In some large residential and light commercial areas, such as villas, restaurants, usually it needs more than
one indoor unit, which in turn requires multiple outdoor units.
Midea’s Mini VRF system solves this problem, and retains buildings’ original aesthetics.

AUTO ADDRESSING

Outdoor unit can distribute addresses for indoor
units automatically.

Wireless and wired controllers can query and
modify each indoor unit’s address.

31

MINI VRF FULL DC INVERTER

Mini VRF 8, 10.5kW Mini VRF 12, 14, 16kW Mini VRF 20, 22.4, 26kW, 40kW, 45kW

SINGLE PHASE

MODEL V80W/DN1 V105W/DN1 V120W/DN1 V140W/DN1 V160W/DN1(B)

Power supply V/Ph/Hz 220-240/1/50 40
15.5
Recommended Fuse Size A 25 32 32 40 6.42
7.2(1.5~8.0) 9.0(2.0~10.0) 17
Cooling Capacity kW 12.5 14
ESEER 7.36 7.4 9
7.2(1.6~8.4) 9.0(2.1~10.5) 7.1 6.68
1
Heating Capacity kW 14.0 16.0
2
Cinodnonoercutnabitle Total capacity 45~130% of outdoor unit capacity
Max. quantity 2088
45 78 3.8
7.93
Compressor Type Rotary Φ9.53(3/8)
Quantity Φ19.1(3/4)
11 11 6000
54
Fan motor Type DC Motor
Quantity 100
11 22 110

Type R410A 3,083.00
32
Refrigerant GWP 2088 2088 2088 2088
Factory charging kg
2.95 2.95 2.8 3.2

CO2 equivalence kg 6.16 6.16 5.85 6.68

Pipe connections Liquid pipe mm(inch) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8)

Gas pipe mm(inch) Φ15.9(5/8) Φ15.9(5/8) Φ15.9(5/8) Φ15.9(5/8)

Air flow rate m3/h 5500 5500 6000 6000

Sound pressure level dB(A) 53 54 54 54

Net dimension (WxHxD) mm 1075 × 966 × 396 900 × 1327 × 400

Packing size (WxHxD) mm 1120 × 1100 × 435 1030 × 1456 × 435

Net weight kg 75.5 75.5 95 99

Gross weight kg 85.5 85.5 105 109

Operating temperature range °C Cooling: -15~43; Heating: -15~27

PRICE £ 1,834.00 2,138.00 2,889.00 2,937.00
16 21
Mi Points 24 28

32

MINI VRF FULL DC INVERTER

3 PHASE

MODEL V120W/DRN1 V140W/DRN1 V160W/DRN1 V180W/DRN1

Power supply V/Ph/Hz 25 380-415/3/50 25
A 12.5 17.5
Recommended Fuse Size kW 7.1 25 25 6.21
14 19
Cooling Capacity kW 14 16
ESEER 7 9
kg 6.68 6.42
kg 1 1
Heating Capacity mm(inch) 16 17.5
mm(inch) 2 2
Cinodnonoercutnabitle Total capacity m3/h 45~130% of outdoor unit capacity
Max. quantity dB(A) 2.8 4.5
mm 5.85 89 9.40
mm Φ9.53(3/8) Φ9.53(3/8)
Compressor Type kg Φ15.9(5/8) Rotary Φ19.1(3/4)
Quantity kg 6000 6800
°C 57 11 59

Fan motor Type 95 DC Motor 107
Quantity 106 118
22
2,865.00 3,305.00
Type 24 R410A 36

Refrigerant Factory charging 3.2 3.8

CO2 equivalence 6.68 7.93
Liquid pipe
Pipe connections Gas pipe Φ9.53(3/8) Φ9.53(3/8)

Φ15.9(5/8) Φ19.1(3/4)

Air flow rate 6000 6000

Sound pressure level 57 57

Net dimension (WxHxD) 900 x 1327 x 400

Packing size (WxHxD) 1030 x 1456 x 435

Net weight 99 100

Gross weight 109 110

Operating temperature range Cooling: -15~43; Heating: -15~27

PRICE £ 2,939.00 3,042.00

Mi Points 28 32

MODEL V200W/DRN1 V224W/DRN1 V260W/DRN1 V400W/DRN1 V450W/DRN1

Power supply V/Ph/Hz 380-415/3/50
A
Recommended Fuse Size kW 32 32 40 40 40

Cooling Capacity kW 20 22.4 26 40 45
ESEER
kg 6.19 6.21 6.42 6.26 6.2
kg
Heating Capacity mm(inch) 22 24.5 28.5 45 50
mm(inch)
Cinodnonoercutnabitle Total capacity m3/h 50~130% of outdoor unit capacity
Max. quantity dB(A)
mm 10 11 12 14 15
mm
Compressor Type kg DC Inverter
Quantity kg
°C 11122

Fan motor Type DC + AC Motor DC Motor
Quantity
22222

Type R410A

Refrigerant Factory charging 4.8 6.2 6.2 9 12

CO2 equivalence 10.02 12.95 12.95 18.79 25.06
Liquid pipe
Pipe connections Gas pipe Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8) Φ12.7(1/2) Φ12.7(1/2)

Φ19.1(3/4) Φ19.1(3/4) Φ19.1(7/8) Φ22.2(7/8) Φ25.4 (1 1/8)

Air flow rate 10999 10494 10494 16575 16575

Sound pressure level 59 59 60 62 62

Net dimension (WxHxD) 1120x1558x528 1360x1650x540 1460x1650x540

Packing size (WxHxD) 1270x1720x565 1450x1785x560 1550x1785x560

Net weight 137 146.5 147 240 275

Gross weight 153 162.5 163 260 290

Operating temperature range Cooling: -15~46; Heating: -15~24 Cooling: -5~48; Heating: -15~24

PRICE £ 3,754.00 4,220.00 4,276.00 6,578.00 7,337.00

Mi Points 40 45 52 80 90

Nominal Conditions: Cooling: indoor 27°C DB, 19°C WB; outdoor 35°C DB, 24°C WB.
Nominal Conditions: Heating: indoor 20°C DB, outdoor 7°C DB, 6°C WB.
Sound Pressure is measured 1.0 in front of the unit and 1.5m above floor level at Nominal Conditions.

33

VRF V4 PLUS R
HEAT RECOVERY SERIES

WIDE APPLICATION RANGE

WIDE CAPACITY RANGE

The V4+ R Series has an extensive range of capacities,
from 8HP to 64HP, meeting all customer requirements
from small to large buildings.

EASY INSTALLATION AND SERVICE WIDE OPERATION RANGE

Simultaneous cooling and heating achieved for The V4+ R Series operates stably under extreme
new designed MS (Mode Switch) box. The newly conditions, ranging from minus 20°C to 48°C.
designed rotating control box can be rotated up to
150 degrees to provide access to the pipeline system
for inspection and maintenance without the need to
remove the control box.

-5°C 48°C

Cooling Mode

-20°C 24°C

Heating Mode

5°C 24°C

Simultaneous Cooling and Heating Mode

LONG PIPING CAPABILITY

PIPING LENGTH CAPABILITY

Total piping length 1000m
Longest length - actual (equivalent) 175m (200m)

Longest length after first branch 90m*

Largest height difference between indoor 70m (110m)
and outdoor units - ODU up (down)

Largest height difference between indoor 30m
units

*The longest length after first branch is 40m as standard but can be extended
to up to 90m under certain conditions. Please contact your local Midea dealer
for further information.

34

VRF V4 PLUS R
HEAT RECOVERY SERIES

HIGH RELIABILITY

DUTY CYCLING

Duty cycling equalizes the running time of the outdoor units in a multiple-unit system and of the compressors
in each unit, significantly extending compressor lifespan.

BACKUP

In a multi-unit system, if one module fails, the other modules provide backup so that the system can continue operating.

PRECISE OIL CONTROL TECHNOLOGY

Five stages of oil control technology ensure all outdoor compressor oil is always kept at a safe level, eliminating any

compressor oil shortage problems.

The 1st stage: Compressor internal oil separation.

The 2nd stage: High-efficiency centrifugal oil separator (with separation efficiency of up to 99%)
ensures that oil is separated from the discharge gas and returned to the
compressors in a timely fashion.

The 3rd stage: Oil balance pipes between compressors ensure even oil distribution to keep
compressors running normally.

The 4th stage: Oil balance pipes among modules
ensure even oil distribution among
modules.

The 5th stage: Auto oil return program monitors
the running time and system status
to ensure reliable oil return.

35

VRF V4 PLUS R
HEAT RECOVERY SERIES

WIDE APPLICATION RANGE

The V4+ R Series has an extensive range of capacities, from 8HP
to 64HP, meeting all customer requirements from small to large
buildings. Midea provides 12 types and more than 100 models
of VRF indoor units to meet varied customer requirements in
a wide range of locations including shopping malls, hospitals,
office buildings, hotels and airports.
36

VRF V4 PLUS R
HEAT RECOVERY SERIES

HP 8 10 12 14 16

MODEL MV-252W/D2RN1T(D) MV-280W/D2RN1T(D) MV-335W/D2RN1T(D) MV-400W/D2RN1T(D) MV-450W/D2RN1T(D)

Power supply V/Ph/Hz 380-415/3/50
A
Recommended Fuse Size kW 25 25 25 40 40
kW
Cooling Capacity 25.2 28 33.5 40 45
Pa
Heating Capacity Pa 27 31.5 37.5 40 45

Cunointnectable indoor Total capacity kg 50~130% of outdoor unit capacity
Max. quantity mm(inch)
mm(inch) 13 16 20 23 26
mm(inch)
Compressor Type mm DC inverter
Quantity mm
m3/h 11122
dB(A)
Type mm DC motor
mm
Fan motor Quantity kg 2
kg
Static pressure °C 0-20 (default)

20-40 (customized) 20-60 (customized) 20-40 (customized)

Type R410A

Refrigerant GWP 2088 2088 2088 2088 2088

Factory charging 10 10 10 13 13

Liquid pipe Φ12.7(1/2) Φ12.7(1/2) Φ15.9(5/8) Φ15.9(5/8) Φ15.9(5/8)

Low pressure gas pipe Φ22.2(7/8) Φ22.2(7/8) Φ25.4(1) Φ28.6(1 1/8) Φ28.6(1 1/8)

Pipe connections High pressure gas pipe Φ19.1(3/4) Φ19.1(3/4) Φ19.1(3/4) Φ22.2(7/8) Φ22.2(7/8)
Hpiipgeh pressure gas balance
Φ19.1 (Φ3/4)

Oil balance pipe Φ6 (Φ1/4)

Air flow rate 12000 12000 13000 15000 15000
56 63
Sound pressure level 59 60 63
255 303
Net dimension (WxHxD) 273 1250×1615×765 322

Packing size (WxHxD) 6,563.00 1305×1790×820 9,964.00
25 90
Net weight 255 255 303

Gross weight 273 273 322

Operating temperature range Cooling: -5~48; Heating: -20~24; Simultaneous Cooling and Heating: -5~24

PRICE £ 6,936.00 7,828.00 9,165.00

Mi Points 56 67 80

HP 18 20 22 24 26
MV-532W/D2RN1T(D) MV-730W/D2RN1T(D)
MODEL MV-560W/D2RN1T(D) MV-615W/D2RN1T(D) MV-680W/D2RN1T(D)
8+10 10+16
Combination 10+10 10+12 10+14
25+25 25+40
Power supply V/Ph/Hz 53.2 380-415/3/50 73
A 58.5 76.5
Recommended Fuse Size kW 25+25 25+25 25+32
kW 29 43
Cooling Capacity 56 61.5 68
kg 2 3
Heating Capacity mm(inch) 63 69 71.5
mm(inch) 2088 2088
uCnointnectable indoor Total capacity mm(inch) 10×2 50~130% of outdoor unit capacity 10+13
Max. quantity mm Φ15.9 (5/8) Φ19.1 (3/4)
mm Φ31.8 (Φ1-1/4) 33 36 39 Φ34.9 (Φ1-3/8)
m3/h Φ28.6 (Φ1-1/8) Φ28.6 (Φ1-1/8)
Compressor Type dB(A) DC inverter
Quantity mm 24000 27000
mm 58 223 60
kg
Fan motor Type kg 255×2 DC motor 255+303
Quantity °C 273×2 273+322
2X2
13,499.00 16,900.00
Type 106 R410A 146

Refrigerant GWP 2088 2088 2088 37

Factory charging 10×2 10×2 10+13

Liquid pipe Φ15.9 (5/8) Φ15.9 (5/8) Φ15.9 (5/8)

Low pressure gas pipe Φ31.8 (Φ1-1/4) Φ31.8 (Φ1-1/4) Φ34.9 (Φ1-3/8)
Φ28.6 (Φ1-1/8) Φ28.6 (Φ1-1/8) Φ28.6 (Φ1-1/8)
Pipe connections High pressure gas pipe
pHiipgeh pressure gas balance
Φ19.1 (Φ3/4)

Oil balance pipe Φ6 (Φ1/4)

Air flow rate 24000 25000 27000

Sound pressure level 58 59 60

Net dimension (WxHxD) (1250×1615×765)×2

Packing size (WxHxD) (1305×1790×820)×2

Net weight 255×2 255×2 255+303

Gross weight 273×2 273×2 273+322

Operating temperature range Cooling: -5~48; Heating: -20~24; Simultaneous Cooling and Heating: -5~24

PRICE £ 13,872.00 14,764.00 16,101.00

Mi Points 112 123 136

Nominal Conditions: Cooling: indoor 27°C DB, 19°C WB; outdoor 35°C DB, 24°C WB.
Nominal Conditions: Heating: indoor 20°C DB, outdoor 7°C DB, 6°C WB.
Sound Pressure is measured 1.0 in front of the unit and 1.5m above floor level at nominal conditions.

VRF V4 PLUS R
HEAT RECOVERY SERIES

HP 28 30 32 34 36
MV-800W/D2RN1T(D) MV-1010W/D2RN1T(D)
MODEL MV-850W/D2RN1T(D) MV-900W/D2RN1T(D) MV-960W/D2RN1T(D)
14+14 10x2 +16
Combination 14+16 16x2 10×2+14
32+32 25+25+40
Power supply V/Ph/Hz 80 380-415/3/50 101
A 80 108
Recommended Fuse Size kW 32+40 40+40 25+25+32
kW 46 59
Cooling Capacity 85 90 96
kg 4 4
Heating Capacity mm(inch) 85 90 103
mm(inch) 2088 2x3
uCnointnectable indoor Total capacity mm(inch) 13×2 50~130% of outdoor unit capacity
Max. quantity mm Φ19.1 (Φ3/4) 2088
mm Φ34.9 (Φ1-3/8) 50 53 56 10×2+13
m3/h Φ28.6 (Φ1-1/8) Φ19.1 (Φ3/4)
Compressor Type dB(A) DC inverter
Quantity mm 30000
mm 61 444
kg
Fan motor Type kg 255+303 DC motor
Quantity °C 273+322
2x2
18,330.00
Type 160 R410A

Refrigerant GWP 2088 2088 2088

Factory charging 13×2 13×2 10×2+13

Liquid pipe Φ19.1 (Φ3/4) Φ19.1 (Φ3/4) Φ19.1 (Φ3/4)

Low pressure gas pipe Φ34.9 (Φ1-3/8) Φ34.9 (Φ1-3/8) Φ41.3 (Φ1-5/8) Φ41.3 (Φ1-5/8)

Pipe connections High pressure gas pipe Φ28.6 (Φ1-1/8) Φ28.6 (Φ1-1/8) Φ34.9 (Φ1-3/8) Φ41.3 (Φ1-5/8)
Hpiipgeh pressure gas balance
Φ19.1 (Φ3/4)

Oil balance pipe Φ6 (Φ1/4)

Air flow rate 30000 30000 39000 39000

Sound pressure level 61 61 61 62

Net dimension (WxHxD) (1250×1615×765)×2 (1250×1615×765)×3

Packing size (WxHxD) (1305×1790×820)×2 (1305×1790×820)×3

Net weight 303×2 303×2 255×2+303 255×2+303

Gross weight 322×2 322×2 273×2+322 273×2+322

Operating temperature range Cooling: -5~48; Heating: -20~24; Simultaneous Cooling and Heating: -5~24

PRICE £ 19,129.00 19,928.00 23,037.00 23,836.00

Mi Points 170 180 192 202

HP 38 40 42 44 46
MV-1065W/D2RN1T(D) MV-1300W/D2RN1T(D)
MODEL MV-1130W/D2RN1T(D) MV-1200W/D2RN1T(D) MV-1250W/D2RN1T(D)
10+12+16 14+16×2
Combination 10+14+16 14x3 14×2+16
25+25+40 32+40+40
Power supply V/Ph/Hz 106.5 380-415/3/50 130
A 114 130
Recommended Fuse Size kW 25+32+40 32+32+32 32+32+40
kW 63 64
Cooling Capacity 113 120 125
kg 4 6
Heating Capacity mm(inch) 116.5 120 125
mm(inch) 2088 2088
Cunointnectable indoor Total capacity mm(inch) 10×2+13 50~130% of outdoor unit capacity 13×3
Max. quantity mm Φ19.1 (Φ3/4) Φ19.1 (Φ3/4)
mm Φ41.3 (Φ1-5/8) 64 64 64 Φ41.3 (Φ1-5/8)
m3/h Φ34.9 (Φ1-3/8) Φ34.9 (Φ1-3/8)
Compressor Type dB(A) DC inverter
Quantity mm 40000 45000
mm 62 566 64
kg
Fan motor Type kg 255×2+303 DC motor 303×3
Quantity °C 273×2+322 322×2
2×3
24,728.00 29,093.00
Type 213 R410A 260

Refrigerant GWP 2088 2088 2088

Factory charging 10+13×2 10+13×2 13×3

Liquid pipe Φ19.1 (Φ3/4) Φ19.1 (Φ3/4) Φ19.1 (Φ3/4)

Low pressure gas pipe Φ41.3 (Φ1-5/8) Φ41.3 (Φ1-5/8) Φ41.3 (Φ1-5/8)

Pipe connections High pressure gas pipe Φ34.9 (Φ1-3/8) Φ34.9 (Φ1-3/8) Φ34.9 (Φ1-3/8)
pHiipgeh pressure gas balance
Φ19.1 (Φ3/4)

Oil balance pipe Φ6 (Φ1/4)

Air flow rate 42000 45000 45000

Sound pressure level 63 64 64

Net dimension (WxHxD) (1250×1615×765)×3

Packing size (WxHxD) (1305×1790×820)×3

Net weight 255+303×2 303×3 303×3

Gross weight 273+322×2 322×2 322×2

Operating temperature range Cooling: -5~48; Heating: -20~24; Simultaneous Cooling and Heating: -5~24

PRICE £ 26,065.00 27,495.00 28,294.00

Mi Points 226 240 250

38

VRF V4 PLUS R
HEAT RECOVERY SERIES

HP 48 50 52 54 56
MV-1350W/D2RN1T(D) MV-1580W/D2RN1T(D)
MODEL MV-1432W/D2RN1T(D) MV-1460W/D2RN1T(D) MV-1515W/D2RN1T(D)
16×3 10+14+16×2
Combination 8+10+16×2 10×2+16×2 10+12+16×2
40+40+40 25+32+40+40
Power supply V/Ph/Hz 135 380-415/3/50 158
A 135 161.5
Recommended Fuse Size kW 25+25+40+40 25+25+40+40 25+25+40+40
kW 64 64
Cooling Capacity 143.2 146 151.5
kg 6 7
Heating Capacity mm(inch) 148.5 153 159
mm(inch) 2×3 2088
Cunointnectable indoor Total capacity mm(inch) 50~130% of outdoor unit capacity 10+13×3
Max. quantity mm 2088 (22×2+28.6×2)
mm 13×3 64 64 64 Φ44.5 (Φ1-3/4)
m3/h Φ19.1 (Φ3/4) Φ38.1 (Φ1-1/2)
Compressor Type dB(A) Φ41.3 (Φ1-5/8) DC inverter
Quantity mm Φ34.9 (Φ1-3/8) 57000
mm 666 65
kg 45000
Fan motor Type kg 64 DC motor 255+303×3
Quantity °C 273+322×3
(1250×1615×765)×3 2×4
(1305×1790×820)×3 36,029.00
Type R410A 316
303×3
Refrigerant GWP 322×3 2088 2088 2088

Factory charging 29,892.00 10×2+13×2 10×2+13×2 10×2+13×2
270
Liquid pipe Φ22.2 (Φ7/8) Φ22.2 (Φ7/8) (22×2+28.6×2)

Low pressure gas pipe Φ44.5 (Φ1-3/4) Φ44.5 (Φ1-3/4) Φ44.5 (Φ1-3/4)

Pipe connections High pressure gas pipe Φ34.9 (Φ1-3/8) Φ34.9 (Φ1-3/8) Φ38.1 (Φ1-1/2)
Hpiipgeh pressure gas balance
Φ19.1 (Φ3/4)

Oil balance pipe Φ6 (Φ1/4)

Air flow rate 54000 54000 55000

Sound pressure level 65 65 65

Net dimension (WxHxD) (1250×1615×765)×4

Packing size (WxHxD) (1305×1790×820)×4

Net weight 255×2+303×2 255×2+303×2 255×2+303×2

Gross weight 273×2+322×2 273×2+322×2 273×2+322×2

Operating temperature range Cooling: -5~48; Heating: -20~24; Simultaneous Cooling and Heating: -5~24

PRICE £ 33,427.00 33,800.00 34,692.00

Mi Points 285 292 303

HP 58 60 62 64
MV-1650W/D2RN1T(D) MV-1800W/D2RN1T(D)
MODEL MV-1700W/D2RN1T(D) MV-1750W/D2RN1T(D)
14×3+16 16×4
Combination 14×2+16×2 14+16×3
32+32+32+40 40+40+40+40
Power supply V/Ph/Hz 165 380-415/3/50 180
A 165 180
Recommended Fuse Size kW 32+32+40+40 32+40+40+40
kW 64 64
Cooling Capacity 170 175
kg 8 8
Heating Capacity mm(inch) 170 175
mm(inch) 2088 2088
Cunointnectable indoor Total capacity mm(inch) 13×4 50~130% of outdoor unit capacity 13×4
Max. quantity mm Φ22.2 (Φ7/8) Φ22.2 (Φ7/8)
mm Φ44.5 (Φ1-3/4) 64 64 Φ44.5 (Φ1-3/4)
m3/h Φ38.1 (Φ1-1/2) Φ38.1 (Φ1-1/2)
Compressor Type dB(A) DC inverter
Quantity mm
mm 88
kg
Fan motor Type kg DC motor
Quantity °C
2×4

Type R410A

Refrigerant GWP 2088 2088

Factory charging 13×4 13×4

Liquid pipe Φ22.2 (Φ7/8) Φ22.2 (Φ7/8)

Low pressure gas pipe Φ44.5 (ΦΦ1-3/4) Φ44.5 (Φ1-3/4)

Pipe connections High pressure gas pipe Φ38.1 (Φ1-1/2) Φ38.1 (Φ1-1/2)
pHiipgeh pressure gas balance
Φ19.1 (Φ3/4)

Oil balance pipe Φ6 (Φ1/4)

Air flow rate 60000 60000 60000 60000
66 66
Sound pressure level 66 66
303×4 303×4
Net dimension (WxHxD) 322×4 (1250×1615×765)×4 322×4

Packing size (WxHxD) 37,459.00 (1305×1790×820)×4 39,856.00
330 360
Net weight 303×4 303×4

Gross weight 322×4 322×4

Operating temperature range Cooling: -5~48; Heating: -20~24; Simultaneous Cooling and Heating: -5~24

PRICE £ 38,258.00 39,057.00

Mi Points 340 350

39

VRF V6 HEAT PUMP SERIES
WIDE APPLICATION RANGE

WIDE CAPACITY RANGE

Starting at 8HP, capacity increases in 2HP increments up to 32HP, which is the world’s largest single VRF unit capacity.

8/10/12HP 14/16/18HP 20/22HP 24/26/28/30/32HP
(with single fan) (with single fan) (with dual fans) (with dual fans)

-5°C 48°C

WIDE OPERATION RANGE Cooling Mode

The V6-i VRF can operate stably in a wide ambient -23°C 24°C
temperature range: from -5oC to 48oC in cooling mode
and from -23oC to 24oC in heating mode. Heating Mode

LONG PIPING CAPABILITY
• Total piping length: 1000m
• Longest piping length – actual (equivalent): 175m (200m)
• Longest piping length after first branch: 40/90*m
• Level difference between IDUs and ODU –

ODU above (below): 90m (110m)

• Level difference between IDUs: 30m

*The longest length after first branch is 40m as standard but can be extended to up to 90m under
certain conditions. Please contact your local Midea dealer for further information.

40

VRF V6 HEAT PUMP SERIES

HIGH RELIABILITY

Precise Oil Control Technology

Four stages of oil control technology ensure all outdoor compressor oil is always kept at a safe level, eliminating any compressor
oil shortage problems.

• Compressor internal oil separation.
• High efficiency centrifugal oil separator (with separation efficiency of up to 99%) ensures that oil is separated from the

discharge gas and returned to the compressors in a timely fashion.

• Oil balance pipes between compressors ensure even oil distribution to keep compressors running normally.
• Auto oil return program monitors the running time and system status to ensure reliable oil return.

Backup Operation

In units with two compressors, if one compressor fails, the other compressor can run on its own for up to 4 days, allowing time
for maintenance or repair whilst maintaining comfort.

Operation compressor

Standby compressor

Failed compressor

Compressor backup

41

VRF V6 HEAT PUMP SERIES

HIGH RELIABILITY

Refrigerant Cooling PCB

The V6-i VRF uses refrigerant cooling technology to cool the electric control box. It decreases the average temperature of electrical
control components by about 8 degrees, guaranteeing the stable and safe running of the control system.

Real-time Refrigerant Amount Monitoring

The temperature and pressure of refrigerant can be real-time monitored by the outdoor unit. When the level of refrigerant is too low
or too high, this can cause damage to the unit and poor performance. V6 outdoor unit can detect excessive or insufficient amounts of
refrigerant, to ensure consistent performance.

Anti-corrosion Protection

Outdoor units are given anti-corrosion treatment for non-extreme conditions as standard and can also be customized with heavy
anti-corrosion treatment on main components for surface protection against corrosive air, acid rain and saline air (for installations in
coastal regions) to extend overall useful life. The integrity of the anti-corrosion treatment is ensured by subjecting major components
and parts to salt mist testing, moisture and heating testing and light aging testing.

Fan motor Screws / bolts / gaskets Heat exchanger aluminum foil
Standard products: Standard products: Standard products:
72h of neutral salt mist 300h of neutral salt mist 72h of neutral salt mist
Heavy anti-corrosion products:
240h of neutral salt mist Heavy anti-corrosion products: Heavy anti-corrosion products:
720h of neutral salt mist 1000h of neutral salt mist
Painted sheet metal 140h of acid salt mist
Standard products:
500h of neutral salt mist Heat exchanger copper pipe
1000h of moisture and heating test Standard products:
500h of light aging test 24h of neutral salt mist
Heavy anti-corrosion products:
1000h of neutral salt mist Heavy anti-corrosion products:
2000h of moisture and heating test 120h of neutral salt mist
720h of light aging test
Electric control box case
42 Standard products:
96h of neutral salt mist

Heavy anti-corrosion products:
240h of neutral salt mist

VRF V6 HEAT PUMP SERIES
Easy Installation and Service

Non-polarized Communication Wiring*

Only one chain of 2-core non-polarized shielded communication wiring required for indoor and outdoor unit communication.

*In installations where relatively strong electromagnetic fields are present, 3-core shielded wiring should be used in order to prevent interference.

Auto Addressing

Outdoor units can distribute addresses to indoor units automatically. Remote and wired controllers can be used to query
or modify each indoor unit’s address.

Automatic Refrigerant Charging/Recycling Function*

Automatic refrigerant charging and recycling make installation
and service easier and more efficient.

*This function is available as a customization option.

Multifunctional PCB

An optional multifunctional small PCB can be installed on the unit’s side
columns, enabling installation and service engineers to activate Auto-
commissioning or check the operating status without removing the
front panel. It can also perform automatic data backup of the last
30 minutes’ operating record.

43

VRF V6 HEAT PUMP SERIES
Enhanced Comfort

Night Silent Mode

The night silent mode feature, which is easily configured on the outdoor unit’s PCB, includes various scheduling
options that can be used to reduce noise levels at times when low noise operation is required.

Enhanced Heating Capacity

Heating capacity is 100% of rated capacity at ambient
temperatures as low as -5oC and 90% of rated
capacity at -15oC.

Intelligent Defrosting Technology

The intelligent defrosting program calculates
the time required for defrosting according to
the actual system status, eliminating heat losses
from unnecessary defrosting. A specialized defrosting
valve reduces time required for defrosting to as little
at four minutes.

44

VRF V6 HEAT PUMP SERIES

8/10/12HP 14/16/18HP
(with single fan) (with single fan)

20/22HP 24/26/28/30/32HP
(with dual fans) (with dual fans)

45

VRF V6 HEAT PUMP SERIES

CAPACITY HP 8 10 12
MODEL MV6-i252W V2GN1-E MV6-i335W V2GN1-E
A MV6-i280W V2GN1-E
Power supply kW 25 32
Recommended Fuse Size kBtu/h 25.2 380-415/3/50 33.5
kW 86 32 114.3
kBtu/h 25.2 33.5
Cooling Capacity 86 28 114.3
kg (lbs.) 13 20
mm(inch) 95.5
mm(inch) 5,998.00 Φ15.9 (5/8)
Heating Capacity m3/h 50 28 Φ28.6 (1 1/8)
dB(A) 95.5
Cunointnectable indoor Total capacity mm Total capacity 50-130% of outdoor unit capacity 57
Max. quantity mm 16
kg Type DC Inverter 7,746.00
Compressor Type kg 67
Quantity °C 1

Fan motor Type DC
Quantity 1
R410A
Refrigerant Type 11
Factory charging

Pipe connections Liquid pipe Φ12.7 (1/2)
Gas pipe
Φ28.6 (1 1/8)
Air flow rate 11000

Sound pressure level 55
990×1635×790
Net dimension (WxHxD) 1090×1805×860
227
Packed dimension (WxHxD) 242

Net weight Cooling: -5 to 48; Heating: -23 to 24

Gross weight 6,388.00

Operating temperature range

PRICE £

Mi Points 56

CAPACITY HP 14 16 18
MODEL MV6-i400W V2GN1-E
A 380-415/3/50 45
Power supply kW 40 40 50
Recommended Fuse Size kBtu/h 40 45 170.6
kW 136.5 50
Cooling Capacity kBtu/h 40 153.5 170.6
136.5 45 29
Heating Capacity kg (lbs.) 23
mm(inch) 153.5 Φ19.1 (3/4)
uCnointnectable indoor Total capacity mm(inch) 9,132.00 50-130% of outdoor unit capacity
Max. quantity m3/h 80 62
dB(A) 26
Compressor Type mm DC Inverter 295
Quantity mm 322
kg 1
Fan motor Type kg DC 10,816.00
Quantity °C 1 100
R410A
Refrigerant Type 13
Factory charging Φ15.9 (5/8)
Φ31.8 (1 1/4)
Pipe connections Liquid pipe 13000
Gas pipe 59
1340×1635×850
Air flow rate 1405×1805×910
277
Sound pressure level 304
Cooling: -5 to 48; Heating: -23 to 24
Net dimension (WxHxD)
10,162.00
Packed dimension (WxHxD) 90

Net weight

Gross weight

Operating temperature range

PRICE £

Mi Points

Nominal Conditions: Cooling: indoor 27°C DB, 19°C WB; outdoor 35°C DB, 24°C WB.
Nominal Conditions: Heating: indoor 20°C DB, outdoor 7°C DB, 6°C WB.
Sound Pressure is measured 1.0 in front of the unit and 1.5m above floor level at nominal conditions.

46

VRF V6 HEAT PUMP SERIES

CAPACITY HP 20 380-415/3/50 22
MODEL MV6-i560W V2GN1-E MV6-i615W V2GN1-E
A 50-130% of outdoor unit capacity
Power supply kW 45 50
Recommended Fuse Size kBtu/h 56 DC Inverter 61.5
kW 191.1 2 209.8
Cooling Capacity kBtu/h 56 DC 61.5
191.1 2 209.8
Heating Capacity kg (lbs.) 33 36
mm(inch) R410A
Cunointnectable indoor Total capacity mm(inch) 12,110.00 17 13,256.00
Max. quantity m3/h 112 123
dB(A) Φ19.1 (3/4)
Compressor Type mm Φ31.8 (1 1/4)
Quantity mm
kg 17000
Fan motor Type kg 63
Quantity °C
1340×1635×825
Refrigerant Type 1405×1805×910
Factory charging
344
Pipe connections Liquid pipe 364
Gas pipe Cooling: -5 to 48; Heating: -23 to 24

Air flow rate

Sound pressure level

Net dimension (WxHxD)

Packed dimension (WxHxD)

Net weight

Gross weight

Operating temperature range

PRICE £

Mi Points

CAPACITY HP 24 26 28 30 32
MV6-I670W V2GN1-E
MODEL A MV6-i730W V2GN1-E MV6-i785W V2GN1-E MV6-i850W V2GN1-E MV6-i900W V2GN1-E
kW 50
Power supply kBtu/h 67 3-phase, 380-415V,50/60Hz
Recommended Fuse Size kW 228.6
kBtu/h 67 60 60 70 70
228.6 73
Cooling Capacity 249.1 78.5 85 90
39 73
249.1 267.8 290 307.1
43
Heating Capacity 78.5 85 90
22
Φ31.8 (1 1/4) 267.8 290 307.1

Cunointnectable indoor Total capacity 25000 50-130% of outdoor unit capacity
Max. quantity
15,687.00 46 50 53
146
Compressor Type DC inverter
Quantity
2

Fan motor Type DC
Quantity
2

Refrigerant Type R410A
Factory charging
kg (lbs.) 25
mm(inch)
Pipe connections Liquid pipe mm(inch) Φ19.1 (3/4) Φ22.2 (7/8)
Gas pipe m3/h
dB(A) 64 Φ38.1 (1 1/2)
mm
Air flow rate mm 407 24000
kg 430
Sound pressure level kg 65
°C 14,258.00
Net dimension (WxHxD) 134 1730×1830×850

Packed dimension (WxHxD) 1800×2000×910

Net weight 429 475

Gross weight 452 507

Operating temperature range Cooling: -5 to 48; Heating: -23 to 24

PRICE £ 17,508.00 18,562.00 19,458.00

Mi Points 157 170 180

Nominal Conditions: Cooling: indoor 27°C DB, 19°C WB; outdoor 35°C DB, 24°C WB.
Nominal Conditions: Heating: indoor 20°C DB, outdoor 7°C DB, 6°C WB.
Sound Pressure is measured 1.0 in front of the unit and 1.5m above floor level at nominal conditions.

47

VRF CONTROLLERS

WIRED CONTROLLERS

K JR-29B K JR-86C K JR-120B WDC-120G/WK

MODEL K JR29B K JR86C K JR120B K JR120C
Fan speed control ✔
Remote signal Mode selection ✔✔✔ ✔
receiver Auto mode ✔
Clean filter Eco mode ✔✔✔ ✔
reminder icon Keyboard lock ✔
Swing function ✔✘✔ ✔
Background light ✔
24 hour timer ✘✘✘ ✔
Clock display ✔
Address setting ✔✘✔ ✔
Remote signal receiver ✔
Clean filter reminder ✔✘✔ ✔
Follow Me function ✔
Silent Key Silent mode ✔✔✔ ✔
One-key 26°C ✔
KJR29B Indoor temperature display ✔✘✔ ✔
(Touch key) °F/°C display ✔
Weekly schedule timer ✔✘✔ ✔
Delay function ✔
Auto restart ✔✘ ✘ ✔
Error reporting ✔
WIDE RANGE OF FUNCTIONS Dimensions (HxWxD)mm ✔✘ ✘
Power supply 120×120×20
A user friendly selection of wired controllers, ✔✘✔ DC 18V
with functions to suit any environmental PRICE £
requirements. Clear LED display screens, 24 ✔✘ ✘ 145.00
hour or weekly timers, auto functions and error
reporting are just some of the functions available ✔✔✔
in the Midea wired controller range.
✘✔✘

✘✔✘

✔✘✔

✘✘✘

✘✘✘

✔✔✔

✘ ✘✔

120×120×20 86×86×18 120×120×20

DC 5V (Supplied by indoor unit)

94.00 80.00 159.00

48

VRF CONTROLLERS

TOUCH SCREEN CENTRALISED CONTROLLERS & BMS INTERFACE

The centralised controller is a multi-functional device that can control up to 64 units within a maximum connection length of 1,200m.
User can group control or individual control and set temperature independently for each unit.

CCM-180A/WS CCM-270A/WS TOUCH SCREEN CENTRAL CONTROLLER

The CCM-180A/WS (6.2”) & CCM270A/WS(10.1”) offers control
of up to 384 indoors units simultaneously.

MODEL CCM-180A/WS CCM-270A/WS
Max. number of indoor units 64 384
Max number of systems 8 48
Mode selection ✔ ✔
Temperature setting ✔ ✔
7-speed fan control ✔ ✔
Outdoor unit Eco mode setting ✔ ✔
Schedule management ✔ ✔
2 permission levels ✔ ✔
Extension function ✔ 8
Daylight saving time ✔ 8
Unit model recognition ✔ ✔
Electricity charge distribution 8 ✔
Visual schematic 8 ✔
Energy management ✔ ✔
Group management ✔ ✔
Error check function ✔ ✔
System parameter querying ✔ 8
LAN access 8 ✔
Dimensions (HxWxD)mm
Power supply 181x124x30 187x276x34
12V 24V AC
PRICE £
1200.00 4000.00

WIRELESS REMOTE CONTROLLERS

INTELLIGENT WI FI CONTROLLER

The CCM-15 offers long distance VRF control via the internet.
VRF can be controlled via smartphone, tablet, laptop or desktop
PC easily through this web controller.

MODEL CCM-15 RM05B RM12D
Max Indoors 64
Description MODEL RM05B RM12D
Date Converter Mode selection ✔ ✔
PRICE £ Temperature setting ✔ ✔
750.00 Fan speed control ✔ ✔
Keyboard lock ✔ ✔
CCM-15 Eco mode ✔ ✔
Swing function ✔ ✔
BMS GATEWAY Air direction control ✔ ✔
24 hour timer ✔ ✔
BMS Gateways available via LonWorks, ModBUS & BACnet interfaces. Night silent mode ✔ ✔
Address setting ✔ ✔
MODEL DESCRIPTION MAX INDOORS PRICE £ Follow Me function ✘ ✔
MD-KNX KNX Gateway 1 Display shut-off ✔ ✔
MD LonGW64/E 400.00 Background light ✔ ✔
LGoantWeworakys 64 Dmimmensions (HxWxD)
CCM-18A/N Modbus Gateway 4,4000.00 Batteries 150x60x20 170x48x20
CCM-18A/N-U Modbus Gateway 64
MD-CCM08/E BACnet Gateway 16 4,4000.00 PRICE £
64 1,5000.00
4,4000.00

1.5V(LR03/AAA)×2

52.00 48.00

49

VRF HEAT PUMP BRANCH JOINTS

MODEL APPEARANCE MODEL PACKED DIMENSIONS NET / GROSS TWO PIPE PRICE £
mm WEIGHT REFRIGERANT SYS-
kg
TEM
BRANCH JOINTS

FQZHW- 255×150×185 1.2 / 1.5 Connecting two 142.00
02N1D outdoor units

BRANCH JOINTS FQZHW- 345×160×285 2.4/3.4 Connecting three 298.00
FOR 03N1D outdoor units
OUTDOOR UNITS

FQZHW- 475×165×300 3.6/4.8 Connecting four 449.00
04N1D outdoor units

FQZHN-01D 290×105×100 0.3/0.4 A*<16.6kW 43.00

FQZHN-02D 290×105×100 0.4/0.6 16.6≤A*<33kW 58.00

BRANCH JOINTS FQZHN-03D 310×130×125 0.6/0.9 33kW≤A*<66kW 93.00
FOR INDOOR
UNIT

FQZHN-04D 350×180×170 1.1/1.5 66kW≤A*<92kW 139.00

FQZHN-05D 365×195×215 1.4/1.9 92kW≤A* 158.00

* A = Total capacity of indoor units connected to this branch joint

50