APPENDIX L TABLE L 701.2(2) (continued) WATER SAVINGS CALCULATOR12 NONRESIDENTIAL BUILDINGS CONSUMPTION (gallons per minute) DURATION (minutes) DAILY WATER USES (gallons) FIXTURE TYPE DAILY USES OCCUPANTS 1.6 gpf toilets 1.6 5 I 4 32 Lavatory faucet - 2,2 gpm 2.2 8 0.25 4 I S Kitchen sink - 2.2 gpm 2.2 6 0.25 4 13 Showerhead - 2.5 gpm 2.5 0.75 8 4 60 Total Daily Volume 123 Annual Work Days 44 822 NONRESIDENTIAL BUILDINGS CONSUMPTION (gallons oer minute) DURATION (minutes) DAILY WATER USES (gallons) FIXTURE TYPE DAILY USES OCCUPANTS 1.6 gpftoilet - male 1.28 5 1 4 26 Lavatory faucet - 1.5 gpm 1.5 8 0.25 4 12 Kitchen sink - 2.2 gpm 2.2 6 0.25 4 13 Showerhead - 2.5 gpm 2.5 0.75 8 4 60 Total Daily Volume Annual Usaee Annual Savings % Reduction 111 40 442 4380 -9.8 percent For SI units: I gallon per minute = 0.06 L/s, 1 gallon = 3.785 L Notes: Consumption values shown as underlined reflect the maximum consumption values associated with the provisions called out in the IAPMO Green Plumbing & Mechanical Code Supplement. 2 To determine estimated savings, insert occupant values (same as Baseline ) and consumption values based on fixtures and fixture fittings installed. i Notes and instructions for Table L 7U 1.2(2): Table L 701.2(2) is an example of a calculator that is capable of helping estimate water savings in residential and nonresidential structures.The "'Duration” of use and '"Daily Uses" values that appear in the table arc estimates and based on previous studies.The first example shown below is a commercial office building w ith 300 occupants. 150 females, and 150 males. The second example is a 3 bedroom residential building.To obtain and use a working copy of this calculator, follow the download and use instructions below. Instructions for download: 1. Go to the IAPMO wrebsitc at wrwwr.iapmogrccn.org to download the water savings calculator. The calculator is a Microsoft Office Excel file (1997 or later), your computer must be capable of running MS Excel. 2. Follow the instructions for downloading and running the file. Instructions for use: 1 . In the Baseline Case section, insert the number of total occupants, male occupants and female occupants that apply to the building in the ' ‘Occupants"column. Unless specific gender ratio values arc provided, assume a 50/50 gender ratio. 2. Copy and paste these same values in the ' 'Occupants” column of the Calculator section. 3. In the Calculator section., insert the consumption values (flow rates in gpm or gallons per flush or per cycle) in the '"Consumption" column. 4. Estimated wratcr savings regarding percent savings versus baseline values, gallons per day and gallons per year will be automatically calculated. 414 2021 UNIFORM PLUMBING CODE


APPENDIX M PEAK WATER DEMAND CALCULATOR M 101.0 General. for the fixture branch or riser in Column |_BJ of the Water Demand Calculator and run Calculator. The flow rate for one fixture branch and one fixture supply shall be the design flow rate of the fixture according to Table M 102.1. M 102.5 Continuous Supply Demand. Continuoussupply demands in gallons per minute (gpm) for lawn sprinklers, air conditioners, hose bibbs, etc. , shall be added to the total estimated demand for the building supply as determined by Section M 102.3. Where there is more than one hose bibb installed on the plumbing system, the demand for only one hose bibb shall be added to the total estimated demand tor the building supply. Where a hose bibb is installed on a fixture branch, the demand of the hose bibb shall be added to the design flow rate for the fixture branch as determined by Section M 102.4, M 102.6 Other Fixtures. Fixtures not included in Table M 102.1 shall be added in Rows 12 through 14 in the Water Demand Calculator as Other Fixture, The probability of use and flow rate for Other Fixtures shall be added by selecting the comparable probability of use and flow rate from Columns [C] and [E]. M 102.7 Size of Water Piping per Appendix A. Except as provided in Section M 102.0 for estimating the demand load for single- and multi-family dwellings, the size of each water piping system shall be determined in accordance with the procedure set forth in Appendix A,After determining the permissible friction loss per 100 feet {30 480 mm) of pipe in accordance with Section A 104,0 and the demand flow in accordance with the Water Demand Calculator, the diameter of the building supply pipe, branches and risers shall be obtained from Chart A 105.1( 1 ) through Chart A 105,1(7), whichever is applicable, in accordance with Section A 105.0 and Section A 106.0. Velocities shall be in accordance with Section A 107.0, Appendix 1 (IS 31), Figure 3 and Figure 4 shall be permitted when sizing PEX systems. M 102.7.1 Minimum Fixture Branch Size. The minimum fixture branch size shall be L /z inch (15 mm) in diameter. M 101.1 Applicability. This appendix provides a method for estimating the demand load for the building water supply and principal branches for single- and multi-family dwellings with water-conserving plumbing fixtures, fixture fittings, and appliances. M 102.0 Demand Load. M 102.1 Water-Conserving Fixtures. Plumbing fixtures, fixture fittings, and appliances shall not exceed the design flow rate in Table M 102.1. TABLE M 102.1 DESIGN FLOW RATE FOR WATER-CONSERVING PLUMBING FIXTURES AND APPLIANCES IN RESIDENTIAL OCCUPANCIES MAXIMUM DESIGN FLOW RATE (gallons per minute) FIXTURE AND APPLIANCE Bar Sink 1.5 Bathtub 5.5 Bidet 2.0 Clothes Washer* 3.5 Combination Bath/Shower 5.5 Dishwasher* 1.3 Kitchen Faucet 2.2 Laundry Faucet (with aerator) Lavatory Faucet 2.0 1.5 Shower, per head 2.0 Water Closet, 1,28 GPF Gravity Tank 3.0 For SI units: I gallon per minute = 0.06 L/s * Clothes washers and dishwashers shall have an energy star label. M 102.2 Water Demand Calculator. The estimated design flow rate for the building supply and principal branches and risers shall be determined by the 1APMO Water Demand Calculator available for download at http://www.iapmo.org/ WEStand/Pagcs/WaterDcmandCaleulator.aspx M 102.3 Meter and Building Supply. To determine the design flow rate for the water meter and building supply, enter the total number of indoor plumbing fixtures and appliances for the building in Column |_BJ of the Water Demand Calculator and run Calculator. See Table M 102.3 for an example. M 102.4 Fixture Branches and Fixture Supplies. To determine the design flow rate tor fixture branches and risers, enter the total number of plumbing fixtures and appliances 2021 UNIFORM PLUMBING CODE 41G


APPENDIX M TABLE M 102.3 WATER DEMAND CALCULATOR EXAMPLE [B] [Cl [D] fE] [A] ENTER NUMBER OF FIXTURES PROBABILITY OF USE (%) ENTER FIXTURE FLOW RATE (GPM) MAXIMUM RECOMMENDED FIXTURE FLOW RATE (GPM) FIXTURE 1 Bar Sink 0 2.0 1,5 1,5 2 Bathtub 0 1.0 5.5 5.5 3 Bidet 0 1.0 2.0 2.0 4 Clothes Washer 1 5.5 3.5 3.5 5 Combination Bath/Shower 1 5.5 5.5 5.5 6 Dishwasher I 0.5 1,3 1,3 7 Kitchen Faucet 1 2.0 2.2 2.2 8 Laundry Faucet tr Lavatory Faucet r 0 2.0 2.0 2.0 9 1 2.0 1.5 1.5 10 Shower, per head 0 4.5 2.0 2.0 LI Water Closet, l .28 GPF Gravity Tank I 1.0 3.0 3.0 12 Other Fixture 1 0 0.0 0.0 6.0 13 Other Fixture 2 0 0.0 0.0 6.0 14 Other Fixture 3 0 0.0 0.0 6.0 Total Number of Fixtures 6 RUN VATER DEMAND CALCULATOR RESET 99th Percentile Demand Flow = 8.5 GPM For SI units: I gallon per minute = 0.66 L s. 1 gallon = 3.78} L M 102.8 Examples Illustrating Use of Water Demand Calculator with Appendix A. Example 1: indoor Water Use Only Use the information given below to find the pipe size for the building supply to a res idential building with six indoor fixtures as shown in Figure 1 [Pipe Section 4]* Given Information: Type of construction: Residential, one-bathroom Friction loss per 100 ft (30 480 mm): 15 psi (103 kPa) Maximum velocity: l kitchen faucet I WC Type of pipe material: L-copper 10 ft/s (3.05 m/s) 1 combination bath/shower 1 dishwasher 1 lavatory faucet 1 clothes washer Fixture number/type: Solution: Step 1 of 2 -Find Demand Load for the Building Supply. The Water Demand Calculator [WDC] in Figure 2 is used to determine the demand load expected from indoor w ater use. The WDC has white-shaded cells and light gray-shaded cells. The values in the light gray cells arc derived from a national survey of indoor water use at homes with efficient fixtures and cannot be changed. The white-shaded cells accept input from the designer. For instance, fixture counts from the given information arc entered in Column |_BJ; the corresponding recommended fixture flow rates arc already provided in Column |_DJ. The flow rates in Column [D] may be reduced only if the manufacturer specifics a lower flow rate for the fixture.Column [E] establishes the upper limits for the flow rates entered into Column [DJ. Clicking the Run W ater Demand Calculator button gives 8.5 gpm (0.54 L/s) asthe estimated indoor w? ater demand for the w?holc building. This result appears in the dark gray box of the WDC in Figure 2. TUB* SHOWER LAVATORY DISHWASHER "V WATER CLOSET KITCHEN SINK 3 CLOTHES WASHER A WATER HEATER FROM METER FIGURE 1 RESIDENTIAL BUILDING WITH SIX INDOOR FIXTURES 416 2021 UNIFORM PLUMBING CODE


APPENDIX M [B] [Cl [D] [E] [A] ENTER NUMBER OF FIXTURES PROBABILITY OF USE (%) ENTER FIXTURE FLOW RATE (GPM) MAXIMUM RECOMMENDED FIXTURE FLOW RATE (GPM) FIXTURE 1 Bar Sink 0 2.0 1,5 1,5 2 Bathtub 0 1.0 5.5 5.5 5 Bidet 0 1.0 2.0 2.0 4 Clothes Washer 1 5.5 3.5 3.5 5 Combination Bath/Shower I 5.5 5.5 5.5 6 Dishwasher 1 0.5 1.3 1.3 7 Kitchen Faucet 1 2.0 2.2 2.2 8 Laundry Faucet 0 2.0 2.0 2.0 9 Lavatory Faucet r 1 2.0 1.5 1.5 10 Shower, per head 0 4.5 2.0 2.0 LI Water Closet, L28 GPF Gravity Tank 1 1.0 3.0 3.0 12 Other Fixture 1 0 0.0 0.0 6.0 13 Other Fixture 2 0 0.0 0.0 6.0 14 Other Fixture 3 0 0.0 0.0 6.0 Total Number of Fixtures 99th Percentile Dema id Flow 6 RUN WATER DEMAND CALCULATOR RESET 8.5 GPM For SI units: I gallon per minute = 0.66 L/s+ 1 gallon : : 3.785 L FIGURE 2 WATER DEMAND CALCULATOR FOR INDOOR USE AT HOME WITH SIX EFFICIENT FIXTURES (EXAMPLE 1). Solution: Step 2 of 2 Building Supply. Chart A 105.1(1) for copper piping systems (from Appendix A of the UPC, shown in Figure 3) is used to determine the pipe size, based on given friction loss* given maximum allowable pipe velocity, given pipe material and the demand load computed in Step 1 . In Figure 3, the intersection of the given friction loss (15 psi) ( 103 kPa) and the maximum allowable pipe velocity (10 ft/s) (3.05 m/s) is labeled point A. The vertical line that descends from point A to the base of the chart Determine the Pipe Size of the intersects four nominal sizes for L-coppcr pipe. These intersection points arc labeled B, C, D, E and correspond to pipe sizes of 1 inch ( 25 mm). inch (20 mm), Vi inch (15 mm) and Vs inch (10 mm), respectively. A horizontal line from points LL C. D, L to the right-hand sideof the chart gives maximum flow rates of 24 gpm ( L5 L/s)* 12 gpm (0.757 L/s), 4.5 gpm (0.28 L/s), and 2.3 gpm (0.145 L/s). respectively. These results arc summarized in Table 1 which shows that a 3A inch (20 mm) type L copper line is the minimum size that can convey the peak water demand of 8.5 gpm (0.54 L/s). TABLE 1 PIPE SIZE OPTIONS FOR BUILDING SUPPLY RIPE DIAMETER (INCH) MAXIMUM FLOW (GPM) POINT IN FIGURE 3 OK FOR BUILDING SUPPLY* E YB 2.3 No D Vi 4.5 No C VA 12 Yes B I 24 Yes For SI units: I inch = 25 mm, 1 gallon per minute = 0.06 L/s * For Building in Examples I , 2, 3h and 4. 2021 UNIFORM PLUMBING CODE 417


APPENDIX M CHARTA 105.1(1) 10000 Copper Tubing Smooth Pipe Type M eooo 6000 5000 Type L 4000 Type K 3000 £000 100C SCO eoo 500 400 300 200 5 E 9 Q. 100 cn 80 o cc 60 50 40 30 20 10 6 6 5 4 3 2 FRICTION LOSS IN HEAD (pounds-force per square inch) PER 100-FOOT LENGTH FIGURE 3 CHART A 105,1(1) FOR FINDING PIPE SIZE For SJ units: 1 foot = 304.8 ram, I gallon per minute -0.06 LA), 1 pound-force per square inch = 6.8947 kPa Solution: Step 1 of 2 -Find Demand Load for the Building Supply. The WDC has been developed exclusively for peak indoor water use which can be viewed as a high-frequency shoit duraFxample 2 : Indoor and Outdoor Water Lise -Find the pipe size for the building supply [figure 1 , Pipe Section 4] if the building in lixamplc 1 adds two outdoor fixtures (hose bibb, each with a fixture flow of 2.0 gpm) {0.13 L/s). 418 2021 UNIFORM PLUMBING CODE


APPENDIX M tion process. Because fixturesfor outdoor water use may operate continuously for very long periods, they arc not included in the WDC To account for water use from one or more outdoor fixtures, add the demand of the single outdoor fixture with the highest flowrate to the calculated demand for indoor water use. With two hose bibbs, the demand of only one hose bibb is included. Hence, in this example, the total demand forthe whole house is 8.5 gpm (0.54 L/s) + 2.0 gpm (0.13 L/s) = 10.5 gpm 0.662 L/s). Solution: Step 2 of 2 — Determine the Pipe Size of the Building Supply. Table 1 shows that at 10.5 gpm (0.662 L/s) the building supply shall be 3A inch (20 mm) in diameter. As illustrated in Example 2, the hose bibb will increase the total demand for the w hole house to 13 gpm (0.820 L/s). Note that a reset button is provided to clear any numbers in Column [BJ from a previous calculation. Solution: Step 2 of 2 — Determine the Pipe Size of the Building Supply. Table 1 shows that at 13 gpm (0.820 L/s) the building supply shall be 1 inch (25 mm) in diameter Example 4: Sizing Branches and Risers-For individual hot and cold branches, repeat Steps 1 and 2. For example, for the hot water branch at the water heater [Figure 1, Pipe Section 3], enter all the fixtures and appliances that use hot water into the Water Demand Calculator (toilets will be excluded ) as seen in Figure 5. Use the calculated demand load to find the pipe size in Step 2. Table 1 show s that at 7.7 (0.49 L/s) gpm, the hot water branch shall be 3A inch (20 mm) in diameter. For each additional hot and cold branch [Figure 1, Pipe Sections 1 and 2], enter the number of fixtures and appliances served by that branch into the WDC and use that demand in Step 2 to determine the branch size. If the branch serves a hose bibb, add the demand of the hose bibb to the calculated demand flow for the branch. As discussed in Example 2, the hose bibb is not to be entered into WDC, since the Calculator is for indoor uses only. When there is only one fixture or appliance served by a fixture branch, the demand flow shall not exceed the fixture flow' rate in Column [E] of the Water Demand Calculator. The fixture flow rate would be used in Step 2 to determine the size of the fixture branch and supply. Example 3: Indoor, Outdoor and Other Fixture Water Use -Find the pipe size for the watersupply [Figure 1 , Pipe Section 4J| if the building in Example 2 adds a kitchen pot filler and a dog bath each writh a faucet flow rate of 5.5 gpm (0.35 L/s). Solution: Step 1 of 2 — Find Demand Load for the Buildiug Supply. The kitchen pot filler and dog bath are not listed in Column [A] of the WDC. To accommodate cases such as this, the WDC provides up to three additional rows for L4Other Fixtures". Enter the kitchen pot filler and dog bath in Column [A] of the WDC and erne: :hc fixture count for each in Column [B]. Find an indoor fixture that has a similar probability of use in Column [CJ and add that to the column. Finally, enter the flowr rate of the kitchen pot filler and dog bath in Column [D]. The estimated indoor wrater demand for the whole building is 11 gpm, as shown in the WDC in Figure 4. [B] [C] fD] [El [A] ENTER NUMBER OF FIXTURES PROBABILITY ENTER FIXTURE OF USE (%) FLOW RATE (GPMJ MAXIMUM RECOMMENDED FIXTURE FLOW RATE (GPM) FIX' URE 1 Bar Sink 0 2.0 1.5 1.5 2 Bathtub 0 J .O 5.5 5.5 3 Bidet 0 1.0 2.0 2.0 4 Clothes Washer 1 5.5 3.5 3.5 5 Combination Bath/Shower I 5.5 5.5 5.5 6 Dishwasher 1 0.5 1.3 1.3 7 Kitchen Faucet I 2.0 2.2 2.2 8 Laundry Faucet r Lavatory Faucet r 0 2.0 2.0 2.0 9 1 2.0 1.5 1.5 10 Shower, per head 0 4.5 2.0 2.0 LI Water Closet, 1.28 GPF Gravity Tank 1 1.0 3.0 3.0 12 Pot Filler 1 2.0 5.5 6.0 13 Dog Bath 1 1.0 5.5 6.0 14 Other Fixture 3 0 0.0 0.0 6.0 Total Number of Fixtures 8 RUN WATER DEMAND CALCULATOR RESET 99th Percentile Demand Flow = 11,0 GPM For SI units: l gallon per minute = 0.66 L/s, 1 gallon = 3.785 L FIGURE 4 WATER DEMAND CALCULATOR TO ACCOMMODATE OTHER FIXTURES (EXAMPLE 3). 2021 UNIFORM PLUMBING CODE 419


APPENDIX M [B] [Cl [D] fE] [A] ENTER NUMBER OF FIXTURES PROBABILITY OF USE (%) ENTER FIXTURE FLOW RATE (GPM) MAXIMUM RECOMMENDED FIXTURE FLOW RATE (GPM) FIXTURE 1 Bar Sink 0 2.0 1,5 1,5 2 Bathtub 0 1.0 5.5 5.5 5 Bidet 0 1.0 2.0 2.0 4 Clothes Washer 1 5.5 3.5 3.5 5 Combination Bath/Shower I 5.5 5.5 5.5 6 Dishwasher 1 0.5 1.3 1.3 7 Kitchen Faucet 1 2.0 2.2 2.2 8 Laundry Faucet 0 2.0 2.0 2.0 9 Lavatory Faucet 1 2.0 1.5 1.5 10 Shower, per head 0 4.5 2.0 2.0 II Water Closet, L28 GPF Gravity Tank 0 1.0 3.0 3.0 12 Other Fixture 1 0 0.0 0.0 6.0 13 Other Fixture 2 0 0.0 0.0 6.0 14 Other Fixture 3 0 0.0 0.0 6.0 Total Number of Fixtures 5 RUN VATER DEMAND CALCULATOR RESET 99th Percentile Demand Flow = 7.7 GPM For SI units: I gallon per minute = 0.66 L/s. 1 gallon -3.78:> L FIGURES WATER DEMAND CALCULATOR FOR THE HOT WATER BRANCH {EXAMPLE 4). 420 2021 UNIFORM PLUMBING CODE


APPENDIX N IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR SCALDING AND LEGIONELLA GROWTH N 101.0 General. N 101.1 Applicability. This appendix provides guidelines on the impact of water temperature in minimizing both scalding and Legionella growth potential associated with occupiablc commercial, institutional, multi-unit residential, and industrial building plumbing systems. This Appendix shall not include single-family residential buildings. This appendix shall not be considered a risk management guidance document for scalding or Legionella. Note: Published documents which address Legionella risk management include ASHRAE 188. ASHRAE Guideline 12, or as required by the Authority Having Jurisdiction. There are additional factors associated with the potential for scalding and Legionella growth other than temperature. For scalding potential, other factors include, but are not limited to, user age, health, body part, length of contact time, and water source. For Legionella growth potential otherfactorsinclude, but are not limited to, water source and plumbing system: size, design, circulation rate, water age, disinfectant residual, piping material and component complexity. building water system and shall be submitted to the Author ity Having Jurisdiction. N 104.0 Potential Exposure. N 104.1 Legionella Growth Potential. The Authority Having Jurisdiction shall have the authority to require documentation to address Legionella growth potential, where water temperatures in a water distribution system arc within rangesshown in Table N 104.1 that pose a Legionella growth potential. N 104.2 Scald Potential. Where the water distribution system' s water tcmperature(s) range poses a scald potential in accordance with Table N 104.1, protection shall be provided in accordance with Chapter 4. N 105.0 Disinfection. N 105.1 Disinfection Documentation. Where required by the Authority Having Jurisdiction, documentation for disinfection of all building water systems shall be provided by the registered design professional in the construction documents. Methods for new construction and any repaired system disinfection shall include, but not be limited to, the chlorination methods and procedures for flushing and disinfection in accordance with Section 609.10. Other or alternative water treatment methods for disinfection shall include, but not be limited to, one of the following methods; (1) Copper-silver ionization methods and procedures, including the following documentation. (a) Copper and silver ionization concentrations shall be included in the documentation. (b) Methods and documentation for monitoring ion levN 102.0 Definitions. N 102.1 Cold Water. Water at a temperature less than 77°F (25^C). N 102.2Tepid Cold Water. Water at a temperature not less than 77°F (25°C) and less than 85°F (29*C). N 102.3 Tepid Water. Water at a temperature not less than 85°F ( 29aC ) and less than 110°F (43°C). N 102.4 Warm Water. Water at a temperature not less than 110*F ( 4TC ) and less than 120°E (49<]C). N 102.5 Tempered Hot Water. Water at a temperature not less than 120°1 (49°C) and less than 130°F (54°C). N 102.6 Hot Water. Water at a temperature not less than 130*F (54"C) and less than 140°F (6(TC). N 102.7 Very Hot Water. Water at a temperature not less than 140*F (60°C) and less than \60°F (7 l°C). N 102.8 Disinfecting Hot Water. Water at a temperature not less than 160^F (7 l "C). N 102.9 Legionella Growth Potential. The likelihood that Legionella bacteria will reproduce. N102.10 Scald Potential. The likelihood of burning the skin. els. (c) Electrode cleaning cycles and methods shall be reported . (2) Ultraviolet light methodsshall include the following documentation: (a) Locations of ultraviolet light units. (b) Cleaning cycles and methods of the quartz sleeves and housing shall be documented. N 103.0 Building Water System Design Documentation. N 103.1 Required Documentation. Construction documents shall be required for new construction, renovation, refurbishment, replacement, or repurposing of an occupiablc 2021 UNIFORM PLUMBING CODE 421


APPENDIX N TABLE N 104.1 CORRELATION BETWEENTEMPERATURE RANGES, LEGIONELLA, AND SCALD POTENTIAL LEGIONELLA GROWTH POTENTIAL 2 WATER DESCRIPTION i TEMPERATURE (°F) SCALD POTENTIAL Cold <77 None Minimal Tepid Cold >77 and <85 None Low Tepid None Hyperthermia is possible after long exposure in a bathtub or whirlpool tub. >85 and <110 Hieh Minimal At 111°F > greater than 220 minutes for second-degree bum. Wa mi >110 and <120 Moderate Tempered Hot Low At 120°F, greater than 5 minutes for second-degree bum, and 10 minutes to third-degree bum; At 124°F, two minutes for second-degree bum, and 4 minutes, 10 seconds for third-degree burn. >120 and <130 Lowr Hot Moderate to Hieh At 130°F, 18 seconds for second-degree burn, and 30 seconds for third-degree burn. High At 140°F, three seconds for second-degree burn, and 5 seconds for third-degree bum; At 150°F, instant for second-degree bum, and less than two seconds for third-degree burn; At 158°F, instant for second-degree burn, and less than a second for third-decree burn. •u Immediate >130 and <140 None Verv Hot m? >140 and <160 None Disinfecting Hot >160 None for SI units:°C = (T-32J/L8 Notes: The infant elderly, and infirmed have a higher potential for scalding at temperatures lower than listed. 2 Temperature ranges reported arc experimentally determined iti a laboratory setting in the absence of a realistic microbial community. Legionella can survive for longer periods of time at temperatures higher and lower than the growth temperature ranges indicated due to changes in their metabolic state and/or protection from thermal disinfection within biofilm or amoeba host organisms. i 422 2021 UNIFORM PLUMBING CODE


USEFULTABLES CONVERSIONTABLES Note: The information contained in these tables arc not part of this American National Standard (ANS) and have not been processed in accordance with ANSP$ requirements for an ANS. As such, these tables may contain material that has not been subjected to public review or a consensus process. In addition, they do not contain requirements necessary for conformance to the standard. UNIT CONVERSIONS MULTIPLY BY TO OBTAIN Square feet (ft2 ) Cubic feet (ft3 ) Gallons ( U. S. liquid) Centimeters of mercury (0°C) Centimeters of mercury (0°C) Feet of water (4°C) Inches of mercury * Kilopascals ( kPa) Poundsforce/square inch (lbf/in 2 ) Gallons (gal) Liters (L) Joules (J) Kilowatts (kW) Watts (W) Kilojoules (kJ) Joule (J) Foot pounds-torce/sccond (fHbt/s) Horsepower (hp) (international ) .43 560 . 43 560 325 851 Acres. Acre-feet Acre-feet Atmosphere (atm) Atmosphere (standard) (atm) Atmosphere (standard ) (atm) Atmosphere (standard ) ( atm) Atmosphere (standard ) (atm) Atmosphere (standard ) (atm) Barrels Barrels British thermal units (Btu) British thermal units/hour (Btu/h) British thermal units hour (Btu/h) British thermal unit hour (Btu/h) British thermal unit hour (Btu/h) . . . ......... British thermal units minute (Btu min) .. British thermal units/minute (Btu/min) .. British thermal unit per hour square __ TB. foot degree Fahrenheit [Btu/(h*fL*°F)] British thermal unit inch per hour foot degree Fahrenheit [Btu*in/(h*ft*°F)] 0.14442279 Candelas per square inch (cd in2 ) Celsius (cC) Celsius (°C) Centimeters (cm) Centimeters of mercury (0' 3C) Centimeters of mercury (0 i3C) Centimeters of mercury (0 :3C) Centimeters of mercury (0' 3C) Circumference Cubic feet (ft3 ) Cubic feet (ft3 ) Cubic feet (ft3 ) Cubic feet (ft3 ) Cubic feet (ft3 ) Cubic feet (ft3 ) Cubic fcct/hour (ftVh) 76.0 76.0 33.90 29.92 101.32501 14.70 42 158.9873 1055.055 0.000293 0.293 1.055056 1055.056 12.97 . .0.02358 5.678263 Watt per square meter kelvin [W/(m *K ) | Watt per meter kelvin [W./(m*K)] Candela per square meters (cd. m2 ) Kelvin (k) Fahrenheit (°F) Inches (in ) Atmosphere (standard ) Feet of water (4°C) Pounds-forcc/squarc feet (lbf/ft2 ) Pounds-forcc/squarc inch (lbf/in 2 ) Radians (rad) Cubic inches (in') Cubic meters (m3 ) Cubic yards (yd3 ) Gallons ( U S. liquid) (gal) Liters (L) Quarts (U S. liquid) T Cubic meters/ hour (nr/h) 1.550003 x 103 , . 9C + 273.15 1.8 x 9C + 32 0.3937 0.01316 0.446 27.84 0.1934 6.283 1728 ..0.0283 0.03704 7.48052 .. ..28.32 .. ..29.92 ..0.0283 2021 UNIFORM PLUMBING CODE 423


USEFULTABLES UNIT CONVERSIONS (continued) MULTIPLY BY TO OBTAIN Cubic fcct/minutc (ftVmin) Cubic fcct/minute (tf/min) Cubic fcct/minutc (ftVmhi) Cubic fcct/sccond (ft3 /s) Cubic fcct/sccond (ftV$) Cubic inches (in3 ) Cubic inches (in3 ) Cubic meters (m3 ), Cubic yards (yd3 ) Cubic yards (yd3 ) Cubic yards (yd3 ) Degrees (deg) Fahrenheit (°1 “ ). Feet (ft) Feet (ft) Feet of water (4°C) Feet of water (4°C) Feet of water (4°C) Feet of water (4°C) Feet/minute (ft/min) Feet/minute (ft/min) Feet/second (ft/s) Feet/sccond (ft/s) Feet/second (ft/s) Foot lambert (fL) Foot pou nds-force (ft*lbf) Foot pounds-force/minute (ft' lbf/min) Foot pounds-force/sccond (ft*lbf/s) Gallons (U.S. liquid (gal) Gallons ( U S. liquid ) (gal) Gallons (U S. liquid ) (gal) Gallons (U S. liquid ) (gal) Gallons (U S. liquid ) (gal) Gallons/day Gallons/minute (gal/min) (gpm) Gallons/minute (gal/min) (gpm) Gallons/minutc (gal/min) (gpm) Gallons/minute (gal/min) (gpm) Gallons/minute (gal/min) (gpm) Grains (gr) Horsepower (hp) Horsepower-hours Horsepower-hours Inch (water column at 60CF) Inches (in) Cubic meters/second (mVs) Gallons/second Liters/second (L/s) Gallons/day Gallons/minutc (gpm) Cubic meters (m3 ) Liters (L) Gallons ( U S, liquid) Cubic feet (ft3 ) Cubic meters (m ) Gallons (U.S. liquid) Radians(rad) Celsius (°C) Meters (m) Millimeters (mm) Atmosphere (standard) (atm) Inches of mercury (0°C) Pounds-torce square feet Pounds-force/squarc inch Feet/sccond (ft/s) Miles/hour (mi/h) Mctcrs/sccoJid (m/s) Milcs/hour (mi/h) Miles/minute (mi/min) Candela per square meter (cd/m2 ) Joules (J) Kilowatts (kW) Kilowatts (kW) Cubic inches (in3 ) Cubic meters (m3 ) Cubic feet (ft3 ) Liters (L) Quarts (U S. liquid) Liters/second Cubic fcct/hour (ft3 h) Cubic meters/minute (m /min) Cubic fcct/sccond (ft3 /s) Cubic mctcrs/sccond (m3 /s) Liters/second (L/s) Kilograms (kg) Kilowatts (kW) Joules (J) Kilowatt-hours (k\V*h) Kilopascals ( kPa) Centimeters (cm) . . .0.000472 0.1247 0.47194 646 316.89 448.831 .1.64 x 10‘5 0.01639 264.17 27 0.76455 201.97 0.0174 .(°F-32)/1.8 0.3048 304.8 0.0295 0.8827 62.43 0.4335 0.01667 0.01136 0.3048 0.6818 0.01136 . . .3.426259 1.355 2.260 x 10‘5 1.356 x 10‘3 231 0.003785 . ..0.1337 3.785 4 4.3 x lO'5 8.0208 . . . 0.003785412 0.00223 6.309020 x lO'5 0.06309 0.00006479 0.7457 2.684 x 10+(5 0.7457 0.24884 2.54 424 2021 UNIFORM PLUMBING CODE


USEFULTABLES UNIT CONVERSIONS (continued) MULTIPLY BY TO OBTAIN Inches (in) Inclies/hou r Inches of mercury (0°C) Inches of mercury (0°C) Inches mercury (0 "C) Inches of mercury (0°C) Inches of water (4 "C) Inches of water (4 "C) Inches of water (4“C) Inches of water (4 "C) Joules (J) Joules (J) Joules (J) Kelvin (K) Kilograms ( kg ) Kilograms (kg) * Kilopascals ( kPa ) Kilometers ( km) Kilometers/hour ( km/h ) Kilowatts (kW) Kilowatts (kW) Kilowatt-hours. Kilowatt-hours Kilowatt-hours Kip (1000 Ibf) Kip-foot Kips per square inch fkip/iir ) Lambert (la). Liters (L). Liters (L). Liters (L). Liters (L). Lumens per square foot (lm/ft2 )(footcandle)... Meters (m) Meters (m) Meters (m) Meters/second (m/s) Meters/second (m/s) Miles (mi) Miles (statute). Miles/hour (mi/h) Miles/hour (mi/h) Miles/hour (mi/h) Miles/hour (mi/h) Miles/hour (mi/h) 25.4 Millimeters (mm) Mi11imeters hou r (mm h) Atmosphere (standard ) (atm) Feet of water (4°C) Kilopascals ( kPa) Pou nds-forec/sq uarc inc h Atmosphere (standard ) (atm) Inches of mercury (0°C) Pounds-forec/sq uarc feet Pounds-forec/sq uarc i JIC h British thermal units (Btus) Foot-pounds Watt-hours Celsius (°C) Pounds (lbs) Tons (short) Pounds-torec/sq uarc inc h Miles (statute ) Miles hour (mi/h) British thermal units/hour (Btus/hour) Horsepower (hp) British thermal units (Btus) Foot-pounds (fWbs) Joules (J) Kiloncwtons (kN) Kiloncwton meters (kN*m) Megapascals (MPa) Candela per square meter (cd nr) Cubic feet (ft3 ) Cubic inches (in3 ) “3 Cubic meters (nr) Gallons (U.S. liquid) Lux (lx) Feet (ft) Inches (in) Yards Feet/second (ft/s) Miles/hour (mi/h) Feet (ft) Kilometers (km) Fcct/minutc (ft/min) Fcet/sccond ( ft s) K_ilomcters/hour (km/h) Mctcrs/minute (m/min) Meters/second (in/s) 25.4 0.03342 1.133 3.3863 0.4912 .. ..0.002458 0.07356 5.202 0.03613 9.480 x 10"* 0.7376 2.778 x 10 ,°K - 273.15 2.2046 1.102 x 10‘3 .. .0.145038 0.6214 0.6214 3412.14 . 1.341 -4 3413 +(, 2.655 x 10 3.6 x 10+<5 4.448222 1.35671 6.8947 3.183099 x 103 0.03531 61.02 0.001 0.2642 .. . .10.76391 3.281 39.37 1.094 3.281 2.237 5280 1.609 88 1.467 1.609344 26.82 .0.44704 2021 UNIFORM PLUMBING CODE 425


USEFULTABLES UNIT CONVERSIONS (continued) MULTIPLY BY TO OBTAIN Millimeters (mm) Millimeters (mm) Millimeters (mm) Minutes (min) Ounces/square inch (oz/in2 ) Ounces/square feet (oz/fr) Ounces (oz) Ounces (oz) Pints Pound-force feet (lbf*ft) Pound-force inch (lbf*in) Pound-force per foot (Ibf/tf) ^S. TB. '"5 Pound-force per square foot (lbf/ft ) Pound-force per square inch (lbf/in2 ) Pound-force per inch ( lbf/in) Pounds/cubic inch (lb/in3 ) .„ Pounds/cubic yard (lb/yd3 ) .. Pounds (lb) Pounds/cubic foot (Ih ft ) ! Pounds/foot (lb/ft) Pounds/squarc inch (lb/in3 ) Pounds/squarc foot (lb/ft ) * Pounds-force (1bf) i Pounds-force/square inch (psi) Pounds-force/square inch (psi) Pounds-force/square inch (psi) Pounds-force/square inch (psi) Quarts (U.S. dry ) (dry qt) Quarts (U.S. liquid) ( liq qt) Quarts (liquid) Radians (rads). Seconds (s) Square acre Square feet (ft2 ) Square feet (ft2 ) Square inches (in2 ) Square inches (in2 ) Square meters (m 2 ) Square miles (mi 2 ) Square miles (mi2 ) Square millimeters (mm2 ) Square yards (yd2 ) Square yards (yd2 ) Temperature ("C) + 17.28 Temperature (°F)-32 Centimeters (cm) Inches (in ) Meters (m) Radians (rads) y Kilograms/square meter (kg/m ) y Kilograms/square meter (kg/m-) Kilograms (kg) Millimeters (mL) Liters (L) Newton meters (N*m) Newton meters (N*m) Newton meters (N*m) Pascal (Pa) Kilopascals ( kPa) Newton meters (N*m) Kilograms cubic meter (kg/m3 ) Kilograms/cubic meter (kg/m3 ) Kilograms (kg) Kilograms/cubic meter (kg/m3 ) Kilograms meters (kg/m) Kilograms-forcc/squarc meter (kg/m2 ) Kilograms-forcc/square meter (kg/m 2 ) Newtons (N) Atmosphere (standard ) (atm) Feet of water (4°C) Inches of mercury (0°C) Kilopascals ( kPa) Cubic inches (in3 ) Cubic inches (in3 ) Liters (L) Degrees (deg) Radians (rads) Square kilometers (km2 ) Square inches (in2 ) Square meters (in2 ) Square millimeters (mm2 ) Square meters (m2 ) Square inches (in2 ) Acres Square kilometers (km2 ) Square inches (in2 ) Square feet (ft2 ) Square meters (m3 ) Temperature (“F) Temperature (°C) 0.1 0.03937 0.001 2.908882 x 10'* 43.94185 0.03051517 0.02834 29.57353 0.4731765 1.355818 0T 129848 14.5939 47.88026 6.89476 175.1268 .2.767990 x 104 0.5932764 0.45359 16.0184 1.4881 703.1 4.882427 4.4482 0.06805 2.307 2.036 6.89476 67.20 57.75 0.9463529 57.30 .4.848137 xlO'* 0.404687 144 . ..0.0929 . . . 645.16 0.000645 1550 640 . . .2.589988 1.550 x 10-3 9 0.8361274 1.8 5 q 426 2021 UNIFORM PLUMBING CODE


USEFULTABLES UNIT CONVERSIONS (continued) MULTIPLY BY TO OBTAIN Ton-forcc (tonf) (2000 Ibf) Toil-force foot (tonf*f/tt) Toil-force per square foot (tonf/ft2 ) Ton-force per square inch (tonf/in2 ) Ton (metric). Tons (long) (2240 lbs) Tons (short) Watts. Watts. Yards (y) 8.896443 . .2.71342 . 95.7605 . 13.7895 Kiloncwtons (kN) Kiloncwton meters (kN*m) Kilopascals ( kPa) Megapascals (MPa) Kilograms (kg) Kilograms (kg) Pounds (lbs) British thermal units per hour (Btus/hour) Horsepower (hp) Meters (m) 1000 1016.047 2000 3.4121 1.341 x 10'3 0.9144 SI SYMBOLS AND PREFIXES SI PREFIXES MULTIPLICATION FACTOR PREFIX SYMBOL 1 000 000 000 000 000 000 E-18 exa E 1 000 000 000 000 000 EI 5 peta P 1 000 000 000 000 E+I2 tera T 1 000 000 000 E-09 G l 000 000 E+06 mega M 1 000 E-Q3 kilo k 100 E-02 hecto h 10 E+01 deka da 04 E-01 deci d 0.01 E-02 centi c 0.001 E-03 milli m 0.000 001 E-06 micro 0.000 000 001 E-09 nano n 0.000 000 000 001 E 12 pico P 0.000 000 000 000 001 E-15 femto f 0.000 000 000 000 000 001 E 18 atto a 2021 UNIFORM PLUMBING CODE 427


USEFULTABLES FLOW IN GALLONS PER MINUTE CONVERTED TO FIXTURE UNITS FOR GRAVITY FLUSH TANKS AND FLUSHOMETERS These tables may be interpolated FIXTURE UNITS FIXTURE UNITS FIXTURE UNITS FLOW GPM FLOW FLOW FLUSH VALVE FLUSHOMETER GPM VALVES FLUSH VALVE TANKS FLUSHOMETER VALVES FLUSH VALVE TANKS FLUSHOMETER VALVES GPM TANKS 1 0 43 99 33 125 506 396 2 1 44 103 35 130 533 430 3 3 45 107 37 135 559 460 4 4 46 1 1 1 39 140 585 490 5 6 47 115 42 145 611 521 6 7 48 119 44 150 638 559 7 8 49 123 46 155 665 596 8 10 50 127 48 160 692 631 9 12 51 130 ^0 165 719 666 10 13 52 135 52 170 748 700 1 1 15 53 141 54 175 778 739 12 16 54 146 57 180 809 775 13 18 55 151 60 185 840 811 14 20 56 155 63 190 874 850 15 21 57 160 66 200 945 931 16 23 58 165 69 210 1018 1009 17 24 59 170 73 220 1091 1091 18 26 60 175 76 230 1173 1173 19 28 62 185 82 240 1254 1254 20 30 64 195 88 250 1335 1335 21 32 66 205 95 260 1418 1418 22 34 5 68 215 102 270 1500 1500 23 36 70 225 108 280 1598 1598 24 39 72 236 116 290 1668 1668 25 42 8 74 245 124 300 1755 1755 26 44 9 76 254 132 310 1845 1845 27 46 10 78 264 140 320 1926 1926 28 49 1 1 80 275 148 330 2018 2018 29 51 12 82 284 158 340 2110 2110 30 54 13 84 294 168 350 2204 2204 31 56 14 86 305 176 360 2298 2298 32 58 15 88 315 186 370 2388 2388 33 60 16 90 325 195 380 2480 2480 34 63 18 92 337 205 390 2575 2575 35 66 20 94 348 214 400 2670 2670 36 69 21 96 359 223 410 2765 2765 37 74 23 98 370 234 420 2862 2862 38 78 25 100 380 245 430 2960 2960 39 83 26 105 406 270 440 3060 3060 40 86 28 110 431 295 450 3150 3150 41 90 30 115 455 329 500 3620 3620 42 95 31 120 479 365 428 2021 UNIFORM PLUMBING CODE


USEFULTABLES AREAS AND CIRCUMFERENCES OF CIRCLES DIAMETER CIRCUMFERENCE AREA Inches Inches Inches mm mm 2 mm2 ]A 6 0,40 10 0.01227 8.0 ] /4 8 0,79 20 0.04909 31,7 H 10 1,18 30 0.11045 71,3 15 1,57 40 0.19635 126.7 3 /4 20 2,36 60 0.44179 285.0 1 25 3.14 80 0.7854 506.7 m 32 3.93 100 1.2272 1,7671 3.1416 791.7 1140,1 2026.8 1Vi 40 4,71 120 2 50 6.28 160 2Vi 65 7.85 200 4.9087 3166.9 3 80 9,43 240 7,0686 4560,4 4 100 12.55 320 12.566 8107.1 5 125 15.71 400 19.635 12 667.7 6 150 18.85 480 28.274 18 241.3 7 175 21.99 560 38.485 24 828.9 8 200 25.13 640 50.265 32 428.9 9 225 28.27 720 63.617 41 043.1 10 250 31.42 800 78.540 50 670.9 EQUAL PERIPHERIES S = 0.8862 D D = 1.1284 S S = 0.2821 C S = 0.7854 D D = 1.2732 S S EQUALAREAS Area of square (S') = 1.2732 x area of circle S T Area of square (S) = 0.6366 x area of circle C S C -KD = 2TTR C = 3.5446 Varea D = 0.3183 C = 2R D = 1.1283 Varea Area =nR2 = 0.7854 D2 Area = 0.07958 C2 = * D2 D R K = 3.1416 4 2021 UNIFORM PLUMBING CODE 429


USEFULTABLES FRICTION LOSS PER FOOT LENGTH [SCHEDULE 80 PVC EXCEEDING CHART A105.1{7)] The following formula should be used for where Schedule 80 IPS CPVC sizes 214"through 107' exceed Chart A 105.1(7): Head loss formula: /4 = 0.2083 (100/01 852 x Q 1.852 / </,4.8655 Where: ML - frictional head loss (feet of water per 100 feet) C= Hazcn-Williams factor ( 150 for CPVC) Q — flow rate (gal/min) dj = inside diameter of pipe (inches) Note: head loss in feet of wrater per 100 feet can be multiplied by 0.4335 to obtain pressure drop in psi Vw= 0.4085 O f df 2 Vw - velocity of water (feet per second ) Velocity formula: Where: 430 2021 UNIFORM PLUMBING CODE


USEFULTABLES FLOW IN PARTLY FILLED (ONE-HALF FULL) PIPES (BASED ON MANNING'S FORMULA WITH n = .012) gpm x 6.31 = Us ft/sec x .305 = m/s in. x 25.4 = mm 8 8 § § I 8 10,000 ° 9,000 8,000 7,000 6,000 o o o O O Q Q O O Q O o o o o o o o 10,000 5,000 4,000 3,000 2,000 1 ,000 1,000 900 800 700 600 <u 500 E 400 CL <13 300 o cc U) 200 5 O 100 100 90 80 70 60 50 40 30 20 10 10 Q Q o O O o SLOPE (feet/feet) 2021 UNIFORM PLUMBING CODE 431


USEFULTABLES FLOW IN PARTLY FILLED (FULL) PIPES (BASED ON MANNING'S FORMULA WITH n = .012) gpm x 6.31 = L/s ft/sec x .305 = m/s in. x 25.4 = mm i (U c E <D EL UJ C o ra > 5 O LL -T' O SLOPE (feet/feet) 432 2021 UNIFORM PLUMBING CODE


INDEX © 2021 International Association of Plumbing and Mechanical Officials, All rights reserved. The copyright in this index is separate and distinct from the copyright in the document that it indexes. The licensing provisions set forth for the document arc not applicable to this index. This index may not be reproduced in whole or in part by any means without the express written permission of 1APMO. - A - ACCESSIBLE, DEFINITION ACCESSIBLE, READILY, DEFINITION ACCESSIBLE PLUMBING FACILITIES For persons with disabilities Protection against contact Where required ACRYLONITRILE-BUTADIENE-STYRENE (ABS) PIPE 203.0 ABANDONED 203.0 Grease interceptors Sewers and sewage disposal ACCESS PANELS ACCESSTO Appliances Backwater valves 1014.3.7 722.0, H 1101.0 . .317.1, 402.10 403.2 403.3 403.1 .507.26, 508.3, 508.4 710.6, 1101.6.4 1503.2.3; 1503.9.7 811.4 7078; 719.5 1210.7.1 203.0, Table 313.3, 701.2, Table 701.2, 705.1 Chemical waste system piping 705.9.4, 903.1, 1101.4 Cleanouts Drips Emergency eyewash and shower equipment Flexible connectors Flushometers Fuel gas meters Fuel gas piping Fuel gas pressure regulators . Fullway valves Grease interceptors Indirect waste receptors Interceptors AIR GAPS Backflow prevention 603.2, Table 603.2, 603.3.1 , Table 603.3.1, 603.4. 4 203.0 416.4 604.5 T 1212.5.3 413.2 . .1208.7.1, E 402.4.1 .1210.3.3.1, 1210.4.4 . .1208.8.2, 1210.5.1 606.2, 710.6 1014.3.4 804.1 1009.3, 1009.5, 1016.4, H 901.5 1208.6.12.7 H 501.12 L 407.4 402.1 L 503.3.6(1) . . . .1603.4,K 105.3. 1 H 501.5 606.3, 606.6, 1210.9, 1210.9. 1 , 1210.9.2, 1210.9. 4, 1212.5.3, 1212.6, 1327.2, E 403.9, E 403.13(2), E 403.13(6) 710.10, 810.3 422.4 1007.1 C 501.2.1 Definition Discharge from drinking water treatment units 611.2 AIRTANK ALTERATIONS AND REPAIRS Fuel gas piping Health care facilities Plumbing systems ALTERNATE MATERIALS, DESIGN, AND METHODS ALTERNATE WATER SOURCE Definition For nonpotable applications . . . For special water features Identification of piping Nonpotable rainwater catchment system . . . Table 1601.5, 1602.4, K 102.2 APPLIANCES Automatically operated . . . Categorized vent diameter/area, definition Connections to building fuel gas piping Definition Direct-vent 710.11 1203.1, 1213.1.2, 1213.4.2 1301.5 102.4, 301.2.5 301.3 Lapped flanges Manholes Meters and submeters . Plumbing fixtures Pool heaters on/off switch Rainwater storage tanks Septic tanks Shutoff valves 203.0 Chapter 15 . . L 406.1 . . .601.3.3 509.3.4, 509.5.71 203.0 1212.0 203.0 206.0, 509.2.6, 509.5.10.1, 509.8.2, 509.12 508.4 806.0, 8070 508.4 508.0 509.10, 510.2.11 509.0 Sumps Toilet facilities Trap seal primers Vacuum pumps Valves for nonpotable application . . . Vent connectors, fuel gas . . Water meters and submeters Water pressure regulators and strainers In attics Indirect waste type . In under-floor spaces On roofs Vent Connectors . . . Venting of .1503.9.5 509.10.10 . L 407.4 . . . .608.2 2021 UNIFORM PLUMBING CODE 433


INDEX APPLICATION FOR PERMIT APPROVED, DEFINITION . . APPROVED TESTING AGENCY, DEFINITION . . . AREA DRAINS ASBESTOS-CEMENT PIPE 104.3 203.0 BALLCOCKS BAPTISTRIES BATHROOM, HALF, DEFINITION BATHROOM GROUP BATHTUB, PROHIBITED TYPE BATHTUBS AND WHIRLPOOL BATHTUBS BIDETS BLOWOFF CONDENSERS BOARD OF APPEALS BOILER BLOWOFF Definition Discharge requirements BONDING JUMPER Bonding of CSST fuel gas piping Definition BOTTLING ESTABLISHMENTS BUILDING DRAIN Definition . Existing . . Material . . Sizing . . . .Table 603.2r 603.5.2 406.1 204.0 204.0, 908.2, C 303.0 405.3 203.0 203.0, 1101.15 Table 510.1.2(5), Table 510.2(5) 203.0, 603.5.9: 1303.5 103.0, 203.0 409.0 402.5, 410.0 810.1, Table 810.1 ASPIRATORS AUTHORITY HAVING JURISDICTION AUTHORITY TO Disconnect gas . . . Plumbing system . . Render gas service AUTOMATIC Drains Flushometer valves Pressure relief valve Pumps 1070 1206.0 .106.5 1205.0 204.0 810.1 K 106.2.4 413.2 608.4 612.72, 1017.1, 1101.6.2, C 501.2.5, H 601.8 411.3 420.3, 504.6 H 601.8 603.5.14 710.9 509.14, 509.14.1 1011.0 1211.2 .204.0 1013.0 204.0 102.4.1 Table 701.2 703.0, Table 703.2, 710.5, C 304.2, Table C 304.2 .712.0 .204.0 Seat cover dispensers . . . Shutoff Siphon, septic tanks . . . . Sprinkler systems Sumps and receiving tanks Vent dampers, fuel gas . . AUTO WASH RACKS Testing BUILDING DRAIN (STORM), DEFINITION BUILDING SEWERS Definition Existing Location 204.0 102.4.1, 715.3 721.0 Table 701.2, 715.1, 720.0 710.5, 7170. Table 7171, C 304.2 723.0 204.0, Chapter 6 309.3, 609.1, 701.3.1, 903.3, 1208.6.8, 1321.72 -B - BACKFILLING . .314.4, 314.4.1, 1210.1.2.1, 1323.5.1, 1323.5.4, 1323.5.5, 1504.7.2, H 601.2 Material Sizing Testing BUILDING SUPPLY BURRED ENDS BACKFLOW Definition Prevention Prevention devices or assembly BACKFLOW CONNECTION BACKFLOW PREVENTERS Approved standards . . . Definition For hot water Integral 204.0 602.2, 602.3 603.1, Table 603.2, 603.3 204.0, 603.0 - C - CAPACITY OF Breathing air cylinders Graywater systems . . Interceptors Irrigation field and mulch basin F 1001.1 1503.2.1 1014.2.1 . Table 603.2 204.0 603.4.5 . .417.2, 417.3, 4174, 603.4.6 603.4.9 E 302.6 603.2 .602.3, 603.3 704.2 1503.2.1, 1504.2, Table 1504.2, 1504.3, 1504.6.2 . . .1310.3.1, 1311.2 D 104.0 710.3 1101.6. 2 501.1,Table 501.1(1) Prohibited locations . . . Protection from damage Required BACKFLOW PREVENTION BACK-TO-BACK FIXTURES BACKWATER VALVES Definition Where Required Medical air compressors . Rectangular scuppers . . . Sewage ejectors or pumps Sump pump Water heaters CAST-IRON PIPE Approved standards . . . . 204.0 710.6 301.2. 4 434 2021 UNIFORM PLUMBING CODE


INDEX Discharge line from ejectors Drainage piping Fittings Flanges Joining Prohibited use CAULKED JOINTS CAULKING FERRULES CERTIFICATION Backflow assembly testers . Medical gas or medical vacuum installers Medical gas or medical vacuum systems Pipe welder, definition . . . . Residential fire sprinklers installers CESSPOOL Abandoned Connections to sewer prohibited . Definition CHECK VALVES In drainage systems 710.4 701.2 301.2.3, 604.6, 1208.6.10.5 1208.6.12.1 705.2, 705.10.1 316.1, 1208.6.3 705.2.1 701.6, Table 701.6 CHLORINATED POLYVINYL CHLORIDE/ALUMINUM/CHLORINATED POLYVINYL CHLORIDE (CPVC-AL-CPVC) PIPE OR TUBING Approved standards, water supply Joining and connections Table 604.1 (see Joints and connections) 911.0 . . .205.0, 1009.0 . . 707.1 - 7073, 70713, 11072 CIRCUIT VENTING CLARIFIERS 205.0, 603.2 CLEANOUT PLUGS OR CAPS CLEANOUTS Access Building sewer . . . Change of direction 1323.10 . .707.8, 719.5, 801.3. 2 719.0 707.4, 719.1, 001.3.2, 803.3, 1002.3 707.8, 7079 814.3.1 7078 707.5, 719.4 707.4, 719.1 719.6 . 707.1, 7072, 707.12 316.1 . . . .7071. Table 7071 1306.0 225.0 612.1 H 801.1 722.0, H 1101.0 714.3 205.0 Clearances . . . . Condensate drain Cover plate Direction of flow . Horizontal drains Manholes Plugs Prohibited use of Size Soil or drain pipes Where required . 710.4, 710,12.1, 710.13.2, 1004.2 In firefighter breathing air replenishment systems F 5017, F 601.5.1,F 701.3 1208.8.1 3171 In fuel gas systems In medical gas and medical vacuum systems In water supply systems .. . . . .707.4, 719.1, 909.1, 910.6, 1002.3, 1008.1, . . .1311.5(2), 1313.5 10171, 1101.13.1, E 301.4 Table 603.2, 603.3, 608.3 811.2 205.0, 811.0 509.5 . .509.5.6.2, 509.5.9 509.5.1.1, 509.5.4.3 205.0 . .509.5.6, 509.5.6.3 509.5.1 509.5.3 509.5.2 509.5.5 509.5.8 509.5.4 CLEARANCE Cleanouts . . Fuel gas vents 707.8, 7079 509.7.3.4, Table 509.73. 4(1), Table 509.73. 4(2) 504.3.1, 504.3. 2 CHEMICAL RESISTANT GLASS PIPE CHEMICAL WASTES CHIMNEYS Cleanouts Decorative Shrouds Definition Existing Factory-built Masonry Metal Size Support Termination CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE ORTUBING Approved standards, water supply . . Definition Joining and connections Water heaters CLEAR WATER WASTE Definition Discharge CLINICAL SINKS CLOSET BENDS CLOSET RINGS CLOSET SCREWS CODE, DEFINITION COMBINATION WASTE AND VENT SYSTEMS COMBUSTIBLE MATERIAL, DEFINITION COMBUSTIBLE PIPING INSTALLATIONS COMBUSTION AIR COMMON VENT, FUEL GAS 205.0 812.1 205.0, 413.1, 1303.7 310.3, 402.6.1 402.6.1 402.6. 2 205.0 205.0, 910.0, Appendix B 205.0 Table 604.1 205.0 (see Joints and connections) 612.4.2, Table 612.5.3.2(6), Table 612.5.3.2(7) 1404.0 506.0 509.6.3, 509.10.2.2, 509.10.2.3, 509.10.3.1, 509.10.72, 510.2.3, 510.2.9, 510.2.15, 510.2.16 Residential sprinklers 2021 UNIFORM PLUMBING CODE 435


INDEX COMPRESSION JOINTS 605.7.1.1 T 605.10.1.1 705.2.2, 719.6, 1208.6.11.3 402.10 Definition Flexible connectors Joining and connections 218.0 604.13 (see Joints and connections) 612.4.2, Table 612.5.3.2(8), Table 612.5.3.2(9) CONCEALED SLIP JOINTS CONCEALING OF WORK PROHIBITED BEFORE INSPECTION 105.1, 105.2.1.1 T 105.2.1.2, 503.2T 1203.2 Residential sprinklers CONDENSATE WASTE AND CONTROL CONDENSATE PUMPS . . . CONDENSERS AND SUMPS CONDUCTORS, STORMWATER 814.0 - 814.6 814.1.1 810.0 CROSS-LINKED POLYETHYLENE-ALUMINUMCROSSLINKED POLYETHYLENE (PEX-AL-PEX) PIPING OR TUBING Approved standards, water supply Definition Flexible connectors Joining and connections . . . . Table 604.1 218.0 604.13 (see Joints and connections) 612.4.2 .205.0+ 1101.12.1, 1101.13.1, 1101.16,, 1103.0, 1602.6, 1602.72, 1603.11, K 103.2, K 104.5, K 106.4 205,0. 602.2, 602.3. 603.1, 811.1, 1321.8.8, 132110.4, 1321.10.7, C 302.1, F 1101.3 205.0 CONTAMINATION Residential sprinklers -D - DESIGN FLOOD ELEVATION DEVELOPED LENGTH Bar and fountain sink trap . . . Definition DWV piping Indirect waste piping Trap arm Water supply piping Wet vent DIELECTRIC INSULATORS DISHWASHING MACHINES . . . . Air gap Approved standards Backflow protection Discharge, drainage Drainage discharge, prohibited Drainage fixture unit (DrU) Energy efficiency Flexible connector length . Water supply fixture units (WSFU) 206.0t 301.4 CONTINUOUS VENT, DEFIN TION CONTINUOUS WASTES Definition Materials CONTROL VALVES 801.4 206.0 707.4, 710.13.2 801.3.1 . .1002.2, Table 1002.2 610.9r A 104.4, A 1072 908.1 205.0 407.5, 701.4 408.3, 408.9, 606.5 -606.7 1303.1 COOLING WATER 808.0 COPPER OR COPPER ALLOY PIPE OR TUBING Fuel gas . . 5071 1208.6.3.2, 1208.6.4.2, Table 1215.2(7) -Table 1215.2(13), E 403.5 (see Joints and connections) 414.0 8073 414.1 414.2 14.3, 8073, 1014.3.2 419.2 T 1014.1.3 Table 702.1 L 403.1 604.12 Joining and connections Medical gas and medical vacuum 1318.4, 1319 1, 1323.4.2 312.9 . 811.1, 1208.6.3.2, 1208.6.4 302.1 903.2 . . . . 604.3, 604.4, A 105.2, E 302.2.1 Penetrating framing members Prohibited use of .Table 610.3, Table A 103.1, Table C 303.2 1504.1, 1504.4, Appendix H H 601.8 Standard weight Underground drainage and vent Water supply DISPOSAL FIELDS DOSING TANKS DRAINAGE SYSTEM Cleanouts Change in direction Damage to public sewer or private sewage disposal system Definition Fixture units Independent systems Indirect waste Joints and connections CRITICAL CARE AREA, DEFINITION CRITICAL LEVEL 707.0, 719.0 205.0 706.0 205.0,Table 603.2, 603.5.1, 603.5.2, 603.5.5, 603.5.13, C 501.3 603.0 305.1, 714.0 206.0 CROSS-CONNECTION CONTROL Table 702.1 CROSS-LINKED POLYETHYLENE (PEX) PIPING OR TUBING Approved standards, water supply . . . 311.0 Chapter 8 Table 604.1 . . . 705.0 436 2021 UNIFORM PLUMBING CODE


INDEX Materials Obstruction of flow Sizing 701.2, Table 701.2, 715.0 310.5 . . . .702.0, Table 702.1, 703.0, Table 703.2, 7170, Table 717.1 708.1 710.0 712.0, 723.0 306.0, 811.1, 1012.1 206.0, 415.0, 809.0, E 501.8 Table 604.1, 605.4 206.0 Drainage system Table 701.2, 701.3, 705.0, 706.0, E 504.3 Firefighter breathing air replenishment systems Fixture F 801.3 . 402.9, 403.2, 4170, 603.5.19,L 402.0 1208.6.5, 1208.6.10, 1208.6.11, 1210.4.1 .509.3.6(2), 509.4.2, 510.2.8, 510.2.9 1503.9. 2 704.1, 704.2 604.2, 604.2.1 .604.0, Table 604.1, Table 701.2, 701.3, 903.0, 1208.6, 1208.6.10, 1208.6.10.5 Slope of piping . . . Sumps and ejectors Testing Waste detrimental to DRINKING FOUNTAINS Fuel gas piping Fuel gas vent DUCTILE IRON PIPE DURHAM SYSTEM, DEFINITION Gray water Inlet, for fixture connections Lead content -E- Material of EFFECTIVE GROUND-FAULT CURRENT PATH,DEFINITION EFFECTIVE OPENING EJECTORS 207.0 207.0, Table 603.3.1 710.2 -710.5, 710.9 - 710.12 Medical gas and medical vacuum Plumbing vent Prohibited Screwed Water supply system . 1320.2, 1320.2.1, 1321.1 903.0 310.1 310.8 604.0, Table 604.1, 605.0, A 1073 .(see Plumbing fixtures) 208.0 704.0 208.0 402.6 402.11 . (see Plumbing fixtures) . . . . 702.1, Table 702.1, C 303.1, Table C 303.3 . . . . 610.3, Table 610.3, 610.10, Table 610.10, A 103.1, Table A 103.1, C 303.1, Table C 303.2 906.3 208.0, 507.12 701.5, 906.5, 906.6, 1102.3, K 103.1.1 EMERGENCY EYEWASH AND SHOWER EQUIPMENT . EXCAVATIONS 416.0 314.0, 1203.2, 1504.4, H 301.1, H 701.4 EXCESSIVE WATER PRESSURE . 608.2 EXPANSION AND CONTRACTION OF PIPE, PROVISION FOR EXPANSION TANKS FIXTURE Branch, definition . . Connections Drain, definition . . . . Flanged connection . Future installations . . Plumbing Units, drainage (DFU) 312.2 608.2, 608.3 -F - F RATING FAUCETS Approved standards Maximum flow rate. 208.0, 1404.3, 1405.3, 1406.4 417.1, 417.4, L 402.5.1 407.2, 420.2, L 402.4, L 402.5 4072.2, 407.4, Table L 402.1, L 402.5. 2, Table L 701.2(1) L 402.4 407.4 Units, water supply (WSFU) Metering Residential kitchen. . . Self closing Separate controls for hot and cold water . Sink faucets Temperature limitation FLAGPOLING OF VENTS FLAMMABLE VAPOR OR FUMES FLASHING 417.5 420.2 407.3, 408.3, 409.4, 410.3, 416.2 417.4 612.0 FLOOD RESISTANT CONSTRUCTION Coastal high hazard area Design flood elevation . . Flood hazard area Flood hazard resistance . FLOOD-LEVEL RIM FLOODED, DEFINITION FLOOR DRAINS Connected into a trap . . Directly connected to drainage system Location Required 205.0, 301.4.1 206.0 208.0 301.4 208.0, 801.3. 2 208.0 418.0 1006.1, 10071 With pull out spouts FIRE SPRINKLERS, RESIDENTIAL FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS FITTINGS Branch Cleanout Dielectric Appendix F 419.2 7071, 707.2 . .605.15,605.16.1, 605.16.3, 705.10. 2, 1322.6.1, E 403.8.2 10071 418.3, 418.4, 10171 408.7, 704.3, 10171, E 501.6 2021 UNIFORM PLUMBING CODE 437


INDEX FLUSHTANKS 208.0, 402.4, 413.1, 413.3, 413.5, 601.2 208.0 208.0, 411.2, 413.1, 603.5.3 208.0 T 413.1 T 413.2, 601.2, 603.5.1, 610.10, Table 610.10, L 402.2.2 . . . .604.1r 604.2 T 605.1.1, 605.1.4, 705.3.1, 705.3.3, 1321.9, 1321.9.2, 1321.11. 1 208.0, 1015.0 General requirements Insulation shield Integral Listing Mechanical draft . . . Obstruction of flow . . Plastic piping Special Termination Wall penetrations . . . FUEL GAS VENT, SIZING Category I appliances Multiple appliances . . 509.0 509.6.1.1 509.2.7 509.1 . . .509.3.3 - 509.3.3.5 509.15 509.4.1 509.4.3 509.6.1, 509.72, 509.8 509.8 FLUSH VALVES, DEFINITION FLUSHOMETER TANKS FLUSHOMETER VALVES FLUX FOG DISPOSAL SYSTEMS . . . FOOD-HANDLING EQUIPMENT AND FIXTURES FOOD WASTE DISPOSER . 509.6.2.1, 510.0 510.2, Table 510.2(1) -Table 510.2(9) 509.6.3, 509.6.3.2, 510.2.13 -510.2.16 509.74(1)(b)t 509.10.2.1, 510.1, 510.1.2, Table 510.1.2(1) -Table 510.1.2(6) 801.3 419.0, 714.4, 1001.2, 1014.1.3 312.6, 603.4.7, 603.5.7, 608.2, 1005.1 1210.1.4, 1210.7.1, 1323.2, 1603.17, K 106.0 906.7 Chapter 12 E 403.8.1 - E 403.8.4 1210.6 1210.4 1213.4 1211.0 1203.0, 1213.0 1210.0 1208.3 1208.6.5, 1208.6. 11 -1208.6.12.4, 1213 2.1, 1213.2.2 1208.6 1210.10 1213.6 1208.4, 1214.0, 1215.0, Table 1215.2(1) -Table 1215.2(36), E 403.3 1210.3.5, Table 1210.3.5.1 . . .1208.6.3.3, 1208.6.4.4, 1210.1, E 401.2, E 403.7, E 403.8.4 Multistory FREEZE PROTECTION Single appliance FROST OR SNOW CLOSURE FUEL GAS PIPING Cathodic protection Change in direction Concealed location Detection of leaks Electrical bonding and grounding Inspection and testing Installation Interconnections Joints and fittings -G - GANG OR GROUP SHOWERS GARBAGE GRINDER GRADE 209.0, 408.3, 408.8 (see f ood waste disposer) Building sewer Definition Horizontal drainage GRAVITY DRAINAGE REQUIRED GRAY WATER,DEFINITION GRAY WATER DIVERTER VALVE,DEFINITION GRAY WATER SYSTEMS .718.1 .209.0 .708.0 .709.0 .209.0 209.0 . . .601.3.3, Table 1501.5, 1501.5.2, 1501.6, 1502.0 1014.0 1014.1 209.0 1014.2.1, Table 1014.2.1 . .1014.3, Table 1014.3.6 1014.2 1014.1.3 .1010.1r 1014.1,H 101.3 710.12 Materials Obstruction of flow Purging Sizing GREASE INTERCEPTORS Approved standards . . Definition Capacity Gravity-type Hydromechanical-type Not required Required GRINDER PUMPS Supports Underground installation FUEL GAS VENTS Appliances not requiring vents Caps Clearance 509.2.1 -H509.6.1(6), 509.7.4(3) 509.7.3.4, Table 509.7.3.4( 1), Table 5097.3.4(2) 509.13, 509.14, 509.14.1 509.2.6 HANDHELD SHOWERS HANGERS HARMFUL WASTES 4173 (see Supports) (see Wastes, detrimental or harmful) 101.3, 102.5 505.4.1T 603.5. 4, C 302.0 HEALTH AND SAFETY HEAT EXCHANGERS Dampers Direct-vent 438 2021 UNIFORM PLUMBING CODE


INDEX HEAT-FUSION WELD JOINTS 210.0, 605.6.1, 605.11.1, 1208.6. 11.2 INDUSTRIAL WASTES Access Approval required Definition Disposal Materials Pretreatment required Prohibited material Vents INSANITARY Defective systems Definition Health and safety INSPECTION AND TESTING Alternative engineering design 811.4 HORIZONTAL BRANCH, DEFINITION HORIZONTAL PIPE, DEFINITION HORIZONTAL-TO-HORIZONTAL DRAINAGE FITTINGS HORIZONTAL-TO-VERTICAL DRAINAGE FITTINGS HOT-MOPPED SHOWER PANS HOT WATER SUPPLY PIPING . . 811.1 210.0 2110 306.0, 811.7 811.2, 811.3, 903.2. 2 306.1, 811.1 811.1 T 903.2. 2 210.0 706.3 811.6 706.2 . . . .(see Shower, pans) 601.2, 609.1, 609.4, 609.12, 610.3, 610.12.1, L 501.0, L 502.0, L 503.0 . . . .(see Building drain) . . . (see Building sewer) 105.3.1 211.0 102.5 105.0 301.3.1 - 301.3.1.2, 301.5.6 105.2 105.2.6 . .105.1, 105.2, 1203.0 T 1213.1r 1321.12, 1324.0, 1406.0, 1501.5, Table 1501.5, 1502.0, 1601.5, Table 1601.5, 1605.0 105.2, 1203.3.1 105.2.3 105.3 (see Authority Having Jurisdiction) HOUSE DRAINS HOUSE SEWERS Final Reinspection -I- Required . . . IDENTIFICATION Cast-iron soil pipe Copper tubing Fuel gas piping Medical gas and medical vacuum systems . . .701.2 . .604.4 1208.7.4 Rough-in . . . Scheduling of Testing INSPECTOR . . . . INSULATION Domestic hot water supply Fuel gas vent Penetrating firestop system Pool covers Service hot water 1318.5, 1323.13 - 1323.13.2, 1323.14, 1323.15 301.2.1 601.3 316.0 211.0, 505.4, 603.5.4, 608.7 Chapters 801.2 807.0 802.0 . . . .603.5.9,1303.5 811.0 801.3.2, 803.3 812.0 .814.1, 814.1.1, 814.5 801.3.3 810.1 902.1 801.4, 804.0 801.6, 806.0, 1303.4.1 813.0 .801.3.2, 803.3, 814.5 803.3 801.2 211.0, Table 703.2, 904.1, 908.2.1, C 601.6 Piping, fittings, traps, and fixtures . Water, nonpotable and potable . INCREASERS AND REDUCERS INDIRECT-FIRED WATER HEATERS . . . .609.11, L 501.2 509.6.1.1 . . . .1404.5, 1405.7 L 503.3.6 L 503.3.3, Table L 503.3.3 604.10.1, E 403.8. 4 INTERCEPTING HOPPERS OR SINKS (see Receptors) INTERCEPTOR (CLARIFIER) Abandoned Auto wash racks Bottling establishments Cleanouts, location Commercial and industrial laundries Definition Grease Industrial Oil and flammable liquid Packing establishments Sand Slaughterhouses Vents INTERMIXING OF METALS PROHIBITED INDIRECT WASTE Air gap or break Appliances Approval required Aspirators Chemical wastes Cleanouts Clear water wastes Condensate Food handling fixtures . . . . High temperature discharge Interceptor Receptors Sterile equipment Swimming pools Traps Vents Where required INDIVIDUAL VENTS Tracer wire . .1014.3.7 . . . .1011.0 . . . 1013.0 7077 . . . .1012.0 211.0 . . . .1014.0 . . .1009.0 10170 . . . .1010.0 . . . .1016.0 . . . .1010.0 . . . .902.1 310.6, 604.1 2021 UNIFORM PLUMBING CODE 439


INDEX INVERT, DEFINITION IRON PIPE SIZE (IPS) PIPE ISLAND FIXTURE,VENTING .211.0 302.0 909.0 PP piping Prohibited fittings and practices 605.11 310.0, 315.2, 604.2, 1321.8.4, 1321.12.3 T 1322.7 . . .605.12 T 705.6, 705.9. 4 310.8, 701.3.1 221.0, 402.10, 605.14, 705.9.1, 1003.2 . . .212.0, 605.1. 4, 705.3.3, A 1073 605.2.2, 605.3.1, 605.12.2, 705.1.2, 705.6.2, 705.9. 4 605.13, 605.16.3, 705.7 705.10. 4 605.1.5, 605.2.3, 605.5. 2, 605.11.3, 605.12.3, 605.16.1, 705.1.3, 705.3.4, 705.4.2, 705.6.3, 705.10.2, 1208.6.9, 1208 6.10.1, 1208.6.10.5, 1322.5, A 1073 105.3 705.9. 4 605.16, 705.10, 1210.1.3.8 705.8 212.0, 605.13.2, 7057.2, 1208.6.10.1, 1322.1, F 1101.2 -JJOINTS AND CONNECTIONS PVC piping . Screwed joint Slip joint . . . 315.0, 605.0, 705.0, 1208.6.11 - 1208.6.13.5, 1320.0 705.1 Table 510.1.2(5), Table 510.2(5) .212.0, 605.1.1 T 609.3, 705.3.1, 705.10.1, 705.10.2, 1208.6.11.1, 1208.6.11.2, 1309.4, 1321.1 604.6, 701.2, 705.2, 705.10.1 705.2.1 605.6.2 T 6057.1, 605.10.1.1 T 605.11.2, 705.2. 2, 1208.6.11.3 ABS Asbestos cement pipe Soldered joint Solvent cement plastic pipe Brazed joint Cast-iron piping Sfain ' ess stee1 p ' pe Caulked joint Compression joint Threaded joint Copper or copper alloy pipe or tubing 605.1, 705.3, 705.10.1, 705.10.2 605.2 605.3 605.4 . . . 705.9. 2, 1101.5, 1213.2.2 605.1.2, 1208.6.10.4 605.5, 705.4 705.9.3 210.0, 605.6.1, 605.11.1, 1208.6.11.2 604.2 . . . .605.1.3, 605.2.1, 605.4.1, 605.5.1, 605.6.2, 6057.1, 605.9. 2, 605.10.1 , 605.11.2, 605.12.1.605.13.1, 605.16.3, 705.1.1, 705.2.2, 705.3.2, 705.4.1.705.6.1. 7057.1, 705.8. 1 , 705.10.4, 1208.6.11.3 . . . .605.6, 1208.6.5 605.7 605.8 605.9 605.10 . .605.2 - 605.3.2.1, 605.6 - 605.12.3, 705.1.1 - 705.1.3, 705.5 - 705.5.1.3, 705.6 -705.6.3, 705.10.3, 1208.6.11, 1210.1.7.1 CPVC piping CPVC-AL-CPVC piping or tubing Ductile iron piping . . Expansion joint . . . . Flared Galvanized steel pipe Ground joints Heat-fusion joints . . Tightness Transition joint . Various materials Vitrified clay Welded joint . . . Lead content . . . Mechanical joints -L - LABELED LAUNDRYTUBS LAVATORIES LAVATORIES IN SETS LAWN SPRINKLERS LEAD 214.0, 301.2 1001.2 407.0, Table 702.1, E 501.4 214.0, Table 702.1 Table 610.3, Table A 103.1 Allowable lead contents Bends and traps Closet rings Flashing Roof drains Sheet Water supply LEADERS 604.2, 604.2.1 701.5, 906.6 402.6.1 1102.3.1 1102.1 408.73, 701.5, 906.6 604.2, 604.2.1 . . . .214.0, 1101.4.3, 1101.12. 1, 1101.13.1, 1101.15, 1101.16, 1101.16.1, 1103.0, Table 1103.1 PE pipe or tubing PE-AL-PE pipe or tubing PE-RT tubing PEX tubing PEX-AL-PEX pipe or tubing . . . Plastic piping, joints, and fittings 440 2021 UNIFORM PLUMBING CODE


INDEX LIQUEFIED PETROLEUM GAS (LP-GAS) Cesspools Cleanouts Drainage piping, joints, and fittings H 801.0 214.0 T 1202.1T 1208.5.1, . .7071 1208.6.73,. 1208.6.11.4, 1212.11, E 401.2, E 403.1, E 403.10 . . .214.0, 303.0, L 302.0 . . . 214.0, 301.2, 402.6.2, 701.2, Table 701.2, 701.3, 705.0 LIQUID WASTES LISTED Fuel gas piping, joints, and fittings 1208.6 - 1208.6.2, 1208.6.3 - 1208.6.5, 1208.6.10, 1208.6.11, 1208.6.12 301.2.1 .1318.0 501.1 LISTING AGENCY LOCATION OF Backwater valves . . 214.0, 301.2 Marking of Medical gas and medical vacuum Potable water piping, joints, and fittings Rainwater catchment system . . . Septic tanks Storm drainage pipe Subsoil drain 710.1, 710.3, 710.4, 710.6, 1006.0, 1101.6. 4, 1503.2.3, 1503.9.1, 1503.9.7 308.0, 402.0 1208.7 - 1208.7.3, E 402.4 -E 402.4.2 1210.9 - 1210.9.4, 1212.5.3,1212.6, E 402.3 1009.3, 1009.5 604.0, 605.0 1602.7 H 501.3 1101.4 1101.4.6 710.8 1003.1 Table 701 2, 903.0 .215.0 1010.0 Fixtures Fuel gas meters Fuel gas valves Sumps or receiving tanks Traps Vents (DWY) MAY, DEFINITION MEAT PACKING AND SLAUGHTERHOUSES MEDICAL GAS AND MEDICAL VACUUM SYSTEMS Alarms Aspirators Category 1 Category 2 Category 3 Category 4 Cleaning Construction documents . Definitions Installation requirements Joints and conneclions . . Labeling and identification Materials Interceptors and separators Medical gas and medical vacuum system valves Plumbing system or sewer on lot 1314.0 3070, 721.1, Table 721.1 . . . .H 101.8 504.1, 504.3 - 504.6, 506.3, 5072, 507.5, 507.10, 507.12 -50715, 50725, 50726, 507.27 214.0 . . . .214.0, Table 603.2 Private sewage disposal system Water heaters . . Chapter 13 1324.4 1303.5 205.0 205.0 205.0 205.0 1318.2 1304.3 215.0 1304.0r 1323.0 132O.0 1323.13 1318.0 1312.0 1319.0 1323.1, Table 1323.1. 4(1) -Table 1323.1. 4(6) 1308.0, 1321.10. 2 1318.1 1305.3, 1314.10, 1315.0 1303.4 1306.0 1324.0 13170 . . . .310.6, 604.1 4072.2 301.2 LOT, DEFINITION LOW HAZARD . . - M - MACERATING TOILET SYSTEMS MAIN,DEFINITION MAINTENANCE 215.0, 710.13 215.0 .102.2,102.3, 1009.6, 1014.1.2, 1501.5, Table 1501.5, 1501.6, 1504.6. 4, 1504.11, 1601.5, Table 1601.5, K 101.5, K 101.5.1, Table K 104.3.3, L 501.5, L 504.2 . . .604.7 Table 604.1,Table 701.2 Medical air systems Medical vacuum systems Pipe sizing MALLEABLE IRON MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL VEHICLE PARKS MARKINGS MATERIALS Alternate Approval required Approved standards Backwater, gate, or ball valves Building drains Building sewers Pressure-regulating equipment Shutoff valves Appendix E (see Identification) Station outlets/inlets Sterilizers and bedpan steamers . . System certification Testing and inspection Warning system METALS,INTERMIXING PROHIBITED METERING FAUCETS MINIMUM STANDARDS 301.3r H 501.13 301.2 301.2.2 710.6 Table 701.2 Table 701.2, 715.1, 720.0 2021 UNIFORM PLUMBING CODE 441


INDEX MULCH, DEFINITION MULCH BASIN 215.0 215.0, 1504.0 - 1504.6.4 Drainage, material 701.2, Table 701.2; 715.1, 720.1 Exposed to sunlight, ABS and PVC Fuel gas Hangers and supports 906.1 . . . .1208.0, 121O.0 313.0, Table 313.3, 1210.3.5, 1210.3.5.1, Table 1210.3.5.1, 1323.4 - 1323.4.5 Table 1323.1. 4(1) -Table 1323.4. 4 601.3 803.0 - N — NATURAL GAS, SPECIFIC GRAVITY NITROGEN,NF, DEFINITION NONCOMBUSTIBLE PIPING INSTALLATIONS 1405.0 NONPOTABLE WATER Alternate water source . . . . Identification Rainwater catchment system Unlawful connections to . . . NONWATER URINALS NUISANCE 1214.1 .216.0 Chapter 15 601.3 Chapter 16 .603.5.11, E 502.3 412.1.1, L 402.3.1 102.5, 216.0 Identification . Indirect waste Joints and connections . . .(see Joints and connections) Medical gas, material . . Plumbing vent, material Protection of 1318.0 Table 701.2, 903.0 312.0, 718.3, 1210.1.3 - 1210.1.5 320.0 612.4, 612.5 . .1101.4 - 1101.4.6 -O - Rehabilitation of Sprinkler system Storm drainage, materials Trenching, excavation, and backfill Underground Water supply, material . . . PITS, SEEPAGE OBSTRUCTIONS OF FLOW OFFSETS Definition . . Drainage . . . 310.5, 315.2 217.0 . .706.4, C 304.3.1, C 304.3.2, C 304.4, C 401.4, C 601.7 1320.2 402.6.3 .509.6.2.2, 510.1.2, 510.2. 4, 510.2.16 .910.5 1017.0 314.0 . .314.4.1, 1210.1.6 .604.0, Table 604.1 221.0, 714.3, 716.1, 722.2 - 722.4, Appendix H 707.1, 7072 Medical gas Prohibited use . . Venting (fuel gas) PLUGS,CAPS, CLEANOUT PLUMBING Additions, alterations, renovations or repairs Appliances Venting (plumbing) OIL AND FLAMMABLE INTERCEPTORS ON-SITETREATED NONPOTABLE WATER SYSTEMS . OPENTRENCH WORK OPENING, EFFECTIVE DEFINITION OVERFLOWS 102.4 218.0, 304.1, 310.5, 313.1, 4172, 603.4.6, 606.5, Table 610.3,Table 702.1, 801.7, 803.3, 806.1, 8070, 808.1, Table A 103.1, L 302.2 218.0, 304.1, 313.1, 603.4.6,Table 610.3, Table 702.1, 814.2.1, 1505.10, 1506.9.3, 1602.9, Table A 103.1, L 501.2 2170, 601.3.3, 1506.0 314.3 207.0 404.2, 413.5, 607.4, 1603.10, 1603.10.1 Appurtenances -P - PATIENT CARE SPACE, DEFINITION PENALTIES PENETRATION FIRESTOP SYSTEMS PERCOLATION TESTS PERMITS, REQUIRED 218.0 106.0 Connected to sewer or private disposal systems Definition Inspection of . . . Official System, definition Tests Uncovered for inspection Vent, definition Vent system, definition . . PLUMBING FIXTURES Access 304.1, 713.1,L 302.2 218.0 105.0 (see Authority Having Jurisdiction) 218.0 105.3, 105.3.1 105.2.1 . .218.0 . .218.0 218.0, 1404.3, 1405.3 1504.3, H 401.0 .104.1, 502.1, 1501.3, 1601.3, E 101.2, E 302.7, H 101.9, K 101.3 PERMITS FEES 104.5,Table 104.5 PIPING Drainage, changes in direction Drainage, existing sewers . . . Drainage, horizontal slope . . . 706.0 715.3 708.O, 718.1 402.1, 413.2, 416.4, 422.4 442 2021 UNIFORM PLUMBING CODE


INDEX 403.1, 403.2, 408.5, 408.6 301.3, 406.3 . . . .301.2.1, 301.2.2, 408.1, 409.1T 410.1, 411.1, 412.1, 415.1,416.1, 4171 - 4174, 418.1, 420.1 704.2 710.1, 710.2 402.5 . .304.1, 406.1, 408.4, 409.2, 415.3, 416.5, 419.2, 420.4, 704.0 . .408.3, 408.9, 601.2, 606.5 -606.7 1303.1, 1505.8. 1506.10 218.0 1001.2, 1002.2, Table 1002.2 . . .610.3, Table 610.4, 610.7 - 610.10,Table 610.10, 702.0, Table 702.1, Table 702.1(1),Table 702.2, 703.0,Table 703.2,Table A 103.1, Table C 303.2,Table C 303.3, C 501.4, C 501.5 . . 408.7, 414.3, 418.0, 704.3, 801.3. 2, 1003.1, 1006.0, 10071, 1014.3.2, 1016.1, 10171, 1101.11, 1505.1, 1506.1, 1602.1,B 101.5, B 101.6.1,Table C 304.2, Table C 304.3, E 501.6 308.0 804.1 402.0, 405.3, 408.3, 408.7, 409.3, 409.6, 412.1.1, 413.1 - 413.3, 413.5, 415.4, 416.3, 418.3 Islands 909.0 Joints 402.2 Material of 401.0, 406.2 - 406.4, 408.7 Minimum number 422.0 Must be connected to sewer 304.1, 713.1 Must be provided with trap 1001.2 Overflows 404.0 Prohibited 310.5, 405.0, 910.7 Quality 401.2 Setting 402.5, 402.6 Size of waste for 702.0,Table 702.1, 703.0, Table 703.2 406.0 Accessibility . Strainers and connections Supply fittings Waste connections .4075, 408.4 402.7 4075, 408.4, 409.2, 415.3, 416.5, 419.2, 420.4 601.2 218.0, 603.1, Table 603.2, 714.5 Alternate materials Approved standards Water supply required POLLUTION POLYVINYL CHLORIDE (PVC) PIPEORTUBING Approved standards, water supply and DWV . Definition Exposed to sunlight Flexible tubing for whirlpool bathtubs Joining and connections Back-to-back Below curb or sewer level Clearance from wall, toilet, urinal Connections, drainage Table 604.1, Table 701.2 218.0 906.1 409.6.1 (see Joints and connections) 408.7 1102.1 Control valves Lining for shower receptors Roof drains POLYETHYLENE (PE) PIPE OR TUBING Approved standards, water supply and DWV Definition Distance from traps Fixture units Table 604.1, Table 701.2 218.0 . . .1208.6.5, Table 1215.2(19) -Table 1215.2(23), Table 1215.2(34) -Table 1215.2(36) (see Joints and connections) 1102.1 Definition Fuel gas Joining and connections Floor drains Roof drains POLYETHYLENE-ALUMINUM-POLYETHYLENE (PE-AL-PE) PIPE OR TUBING Approved standards, water supply Definition Joining and connections Table 604.1 218.0 (see Joints and connections) Improper location of Indirect wastes . . . Installation of . . . . POLYETHYLENE OF RAISED TEMPERATURE (PE-RT) PIPE ORTUBING Approved standards, water supply Definition Table 604.1 218.0 . . . .604.13 (see Joints and connections) Flexible connectors . . . Joining and connections POLYPROPYLENE (PP) PIPE ORTUBING Approved standards, water supply Chemical waste Definition Joining and connections Table 604.1 811.2 218.0 (see Joints and connections) Roof drains 1102.1 POLYVINYLIDENE FLUORIDE (PVDF) PIPEORTUBING Chemical waste Definition 811.2 Special fixtures . . . .218.0 2021 UNIFORM PLUMBING CODE 443


INDEX POTABLE RAINWATER CATCHMENT SYSTEMS POTABLE WATER Connections Water Heaters Water Supply PRIMARY SETTLING TANKS PRIVATE OR PRIVATE USE, DEFINITION PRIVATE SEWAGE Capacity of system Construction . . . . . . .504.4, 504.6, 505.2 608.2 - 608.4, E 302.5 902.1 218.0 Appendix K 603.4. 4, 603.5.6, 603.5.7, 603.5.10 - 603.5.12, 603.5.14, 603.5.20, 801.5, 1303.5 218.0 603.2 609.10 . . . .H 101.7 H 201.0, H 701.1 H 501.3r H 601.9, H 701.3, H 801.3 218.0 . H 101.6, H 501.2, H 501.11, H 901.4, H 901.7 . . .218.0, 713.2 T Appendix H H 101.2 105.0 721.0, H 101.8, Table H 101.8 602.2, 602.4, E 302.1 Definition Devices or assemblies Disinfection Protection from heat transfer medium Heating identification Joints and fittings Materials Outlets Protection of Sizing piping Supply required Tanks Unlawful connection to Definition Design . 505.4.1, C 302.2 501.1 , L 507.0 601.3 604.2, 604.6, 605.0 604.1,Table 604.1 603.5.17 602.0, 603.0 610.0,Appendix A 601.2, E 302.1 607.0 . . .602.0, 603.5.11, 1503.3, 1505.4, 1506.4, 1602.4, E 502.3, K 102.2 606.0 420.3, L 201.0 605.1.3, 605.1.3.2, 605.13.1, 605.16.1, 705.7.1 Disposal systems General requirements Inspections Location PRIVATE WATER SUPPLY PROHIBITED Appliances Concealed gas piping 310.5 1210.4.2, 1212.3.1, 1212.5.3, 1323.6 Concealment of defects 309.2 Concealment of work before inspection . . . . .105.0, 503.2,. Valves 1203.0, 1406.1 PRE-RINSE SPRAY VALVES PRESSED FITTINGS Connections Sewer . Waste . 714.3 . .310.3, 404.2, 603.4.4, 805.1, 8073, 810.1 .602.0, 603.4. 4, E 502.3 . . . .903.2.2, 1208.6. 4.2 305.1, 312.3, 312.6 310.5, 1210.10 603.4. 4, 805.1, 8073, 810.1 509.1.2, 714.2, 1603.4.2, K 104.2 310.0, 315.2, 604.2 310.5, 405.0 PRESSURE DRAINAGE CONNECTIONS PRESSURE, EXCESSIVE, WATER PRESSURE-LOCK-TYPE CONNECTION, DEFINITION PRESSURE LOSSES,WATER . . PRESSURE REGULATORS 805.0 608.2 Water Copper tubing, use of Damage to drainage system Devices Direct drainage 218.0 610.2 Firefighter breathing air replenishment systems Fuel gas Discharge F 501.8 50720, 507.21, 507.22, 1202.1, 1208.8, 1210.9, 1215.1.3 Fittings Fixtures Food waste disposal, connection to Fuel gas piping Industrial waste disposal Installations Joints and connections . Medical gas and medical vacuum Water PRESSURE-RELIEF VALVES Definition Differential, backflow prevention Discharge Firefighter breathing air replenishment systems 1014.1.3 1208.6.4.3, 1210.3. 4 306.2 312.2, 602.1 . . .315.2, 605.1. 4, 605.6.2, 1321.12.3, 1322.7 . . .415.4, 1210.3.4, 1503.6 F 801.4, H 501.10, H 501.13, K 103.1.1, L 503.1.1 1321.10.2 . . .608.2 224.0 603.3.7 Table 603.2 608.5 Locations Materials F 501.1, F 501.8, F 701.3 1308.2,1308.3, 1310.4, 1316.1 Medical gas and medical vacuum piping Oxygen 1323.3.1 1213.1.6 Medical gas and medical vacuum 444 2021 UNIFORM PLUMBING CODE


INDEX Pipes in concrete or masonry Practices 312.2 .102.4.1, 104.1, 106.0, 303.1, 305.1, 309.2, 310.0r 312.2r 312.6, 502.1, 602.0r 714.1, 1101.3, 1204.3, 1205.0, 1206.3, 1501.3, K 101.3, L 302.1 804.1 310.4 1004.0 405.2, E 501.5 -Q - QUALITY AND WEIGHT OF MATERIALS, GENERAL REGULATIONS 301.2.1, 301.2.2, 301.3, 301.5 . 401.2 219.0 QUALITY OF FIXTURES QUICK-DISCONNECT DEVICE, DEFINITION -R - Receptors, location of Systems Traps Trough type urinals Urinals and water closets on a combination waste and vent system Vent termination Water piping PROPERTY LINE,TERMINATION OFVENT PROTECTION FROM Corrosion RAINWATER, DEFINITION RAINWATER CATCHMENT SYSTEMS 220.0 220.0,601.3.3, Chapter 16, Appendix K RAINWATER DIVERSION VALVES RAINWATER STORAGETANK DEFINITION REAMING PIPES 910.7 906.3 1503.2.4 312.6, 604.2, 720.1 906.2 220.0 309.3, 605.1.1 - 605.1.2, 605.1.3.2, 605.1.3.3, 605.1. 4, 609.1, 701.3.1, 705.3.1r 705.3.3, 903.3 710.2, 710.3r 710.7 - 710 10, 710.13.1 312.1, 312.4, 402.3, 402.6.2, 402.6.3, 506.9, 5075, 508.1.2, 509.5.3, 509.7 509.10.1 , 509.10.1.2, 509.10.1.3, 603.5.14.1. 603.5.14.2, 609.3, 710.4, 710.8, 810.2, 811.2, 814.1, 1004.1,1208.6.4.4, 1208.71.1, 1210.1.3, 1210.3, 1210.4. 4, 1310.4, 1323.2, 1323.3,1503.9.1 , 1603.3, C 501.3, E 301.3.2, E 403.5, E 403.6, E 403.8.2, E 403.8.4, E 502.7, F 501.4, H 501.3, H 501.13, K 105.2, K 106.2.2 . .1503.9.1,1603.3, H 501.3, K 105.2 312.6, 603.4.7 1210.1.4, 1210.7.1, 1603.17, 5072, 1323.4.5 RECEIVING TANKS OR SUMPS RECEPTORS Definition . . . Indirect waste 220.0 414.3, 801.2, 801.3.2, 801.3.3, 801.4, 801.6, 801.7 804.0, 8071, 810.4, 814.5, 902.2, 1303.4.1 Shower 408.1, 408.5 - 408.7 RECLAIMED (RECYCLED) WATER SYSTEMS . . . . Decay 220.0, Freezing 601.3.3, 1505.0 REDUCED PRESSURE DETECTOR FIRE PROTECTION BACKFLOW ASSEMBLY REDUCERS REFRIGERATORS REGULATORS Backpressure Draft Seismic PROTECTION OF Fuel gas meters Piping materials and structures Table 603.2, 603.3.9, 603.5.14 316.0 801.3 . . . .1208.7.1, 1208.7.3 312.0, 314.4, 1210.1 603.0 1002.0,1005.1, 1007.0 . . .504.3 - 504.6, 505.2, 507.2, 507.12 -50715 218.0 218.0 408.8 . . .218.0, 605.1.3, 605.1.3.3, 605.2.1 Potable water supply Trap seals Water heaters . . . . 5079 506.1.2, 509.12.3 - 509.12.5, 509.15 F 501.8 . . .50720 - 507.22, 1202.1, 1208.3,1208.8 - 1208.12, 1213.1.5, 1214.1, 1215.1.3, E 404.0, E 404.4, E 404.5. 2 Medical gas and medical vacuum . . .1308.3, 1321.10. 2 Water supply Firefighter breathing air Fuel gas supply PUBLIC OR PUBLIC USE, DEFINITION PUBLIC SEWER, DEFINITION PUBLIC SHOWER FLOORS PUSH FIT FITTINGS 608.2 2021 UNIFORM PLUMBING CODE 445


INDEX RELIEF VENTS Connections Definition Interceptors REMOTE OUTLET, DEFINITION . REPAIRING Detective gas pipe, prohibited REPAIRS AND ALTERATIONSTO PLUMBING AND DRAINAGE SYSTEMS REQUIRED Air gaps or air breaks Appurtenances . . . . 9070, 911.3, B 101.4 805.1 220.0 1009.4 220.0 ROOF DRAINAGE Combined . . . Controlled-flow Primary Secondary . . . Separate piping ROOF GUTTERS . . 1101.12, Appendix D 1101.12.2.2. 2 1105.0 1101.12.1 1101.12. 2 1101.12.2.2.1 1101.12.1, 1103.3, Table 1103.3, 1602.6, 1602.72, 1603.15, 1603.20,K 103.2, K 103.2, K 105.12, K 106.3 1208.6.8 102.4 ROOF,TERMINATION OF VENTS ABOVE 801.2 1505.10, 1506.9.3, 1602.9 509.6.1, 905.4, 906.1, 906.3, 906.5, 906.7 220.0, K 106.2 220.0 ROOF WASHERS ROUGHING-IN, DEFINITION Area of subsurface irrigation fields and mulch basins . . . Drainage or sewer connections Filters Flushing devices Fuel gas pipe size Fuel gas supply Gravity drainage Hot and cold water Inspections 1504.2 304.1, 713.0 1506.9.5, 1603.19 413.1 1215.0 1214.0 709.0 601.2.1 ,1406.0,. 1502.3.4, 1605.3.4 609.9 -S - SADDLE,SLEEVE, BAND OUTLETS, PROHIBITED SAFETY AND HEALTH SAFETY DEVICES SAND INTERCEPTORS Cleanout for Construction and size Definition Design Discharge Location Maintenance Required Vent, required and not required Water seals SANITARY TEES, PERMISSIBLE USE . . 310.1 102.5 504.4 - 504.6, 505.2, 608.0 1016.0 7077 1016.3 221.0 1009.3 1009.7, 1016.1 1009.5 1009.6 1009.1, 1016.1 Low-pressure cutoff Medical gas and medical vacuum pipe size Permits Plans Plumbing fixtures Tests 1323.1 104.0 103.3 422.0, Table 422.1 1502.2 - 1502.3. 4, 1504.10, 1505.5, 1506.5, 1602.5 . .901.2 105.2.5 .1014.1 105.3.2 902.1, 1002.1, 1016.4 1009.3, 1016.4 Vents RESPONSIBLE FORTESTING RESTAURANT, GREASE INTERCEPTORS RETESTING RISERS 706.2, C 601.3, C 601.4 1205.2, 1206.3 221.0 .222.0, 315.1, 412.1.1,413.4, 901.3, 912.2, 1005.0, 10070, C 601.1, E 501.6 . . 221.0 .902.1 SCREW JOINTS SDRt DEFINITION Fuel gas 1208.6.7 1210.1.7 1210.4.4, SEAL,TRAP E 403.6, E 404.3 Medical gas and medical vacuum Sewer Water 1323.3, 1323.13.2 E 504.6, E 504.6.2 220.0, 408.10, 610.1, 1502.3.3, A 103.1, A 106.1, A 106.2, A 108.1, E 302.1, E 302.4, E 503.2, E 505.4, L 503.3.7 312.12 . .220.0, 1101.12. 1, 1101.12.2, 1101.15, 1102.0, Table 1103.1, 1106.3, 11072.1, K 105.12 SEAM, WELDED, DEFINITION . . . SECONDARY INTERCEPTORS SECONDARY TEMPERATURE LIMITING DEVICE SEDIMENTTRAPS SEEPAGE PITS Abandoned Area of disposal Capacity Combination with disposal fields Connection to sewer prohibited 505.2 1210.7.2, 1212.9 H 701.0 722.2 H 301.0 H 701.1 H 601.4 714.3 RODENTPROOFING ROOF DRAINS . . . . 446 2021 UNIFORM PLUMBING CODE


INDEX Construction Definition Location Markings Multiple installations Soil absorption SELF-CLEANING TRAPS SEPARATE PLUMBING AND DRAINAGE SYSTEMS . . . SEPARATE VENTING H 701.3 221.0 721.0r H 101.e; Table H 101.8 716.1 H 701.2 . . Table H 201.1(2), H 301.1 1003.1 Damage to . . . . .305.1r 306.1, 714.1; 718.3, 811.1, 1009.1 . . .312.3, 718.3 T 720.1 721.2 . .710.2, 710.3, 710.10 .102.4.1, 713.6, 715.3 708.0, 718.0 . . . .1503.0 - 1503.9.7 Depth of Easements for Ejectors Existing Grade and support of Gray water Independent system required Inspections Joints and connections . . . . Location 311.0 311.0 811.6, 906.3 . . . .1009.0 105.0 705.0 . . . .307.0, 312.3, 718.3, 720.0, 721.0, Table 721.1 701.0, Table 701.2, 715.0, 720.1 SEPARATORS SEPTICTANKS Abandoned . . . Capacity Connections . . Connections to sewer prohibited Construction Definition Location of Markings Vents SERVICE, AUTHORITY TO RENDER GAS SETTING FIXTURES SETTLINGTANKS SEWAGE Definition . Disposal of 722.2 H 201.0, Table H 201.1(1) H 601.7 714.3 H 501.0 221.0 H 101.8,Table H 101.8 716.1 H 501.8 1205.0 .402.5 .902.1 Materials Mobile home and recreational vehicle parks Must be on same lot as building Private sewage disposal systems Prohibited connections E 301.0, E 504.0 . . . .307.1, 721.1 . . .713.0, 714.0 . .603.4.4,714.2, 714.3, E 502.7 1505.11 . . .709.1, 713.0 Table 702.1, 703.2, Table 703.2, 710.5, 717.0, Table 7171, C 304.2, Table C 304.2, C 601.9 1101.3, 1101.16. 2 718.2 723.0 904.1 609.2, 720.0 221.0 408.7, 408.73, 701.5, 906.6 .221.0, Table 313.3, 705.2. 2 221.0 310.5, 706.0 221.0 Reclaimed (recycled) water Required Size of building 221.0 303.0, 709.0, 713.0, 714.0, 1014.1,1503.2, E 301.1, E 504.1, L 302.1 Storm water Support Testing of Vents Water pipe in trench SHALL, DEFINITION . . SHEET LEAD SEWAGE DISPOSAL SYSTEMS, PRIVATE Abandoned Commercial food waste grinders Design Holding tank Inspection and testing Location .Appendix H 722.2 714.4 . . . .H 101.6 714.5 . . .H 1001.0 3070, 721.0, H 101.8,Table H 101.8 715.0 904.1 . . . .221.0, 710.2, 710.3, 710.10 . . . .221.0, 710.2, 710.3, 710.13 Chapter 7 722.0 312.3, 715.1, 718.3, Table 721.1 713.2, 713.4 204.0 701.0, Table 701.2, 715.0 719.0 304.0, 713.0 715.0 - 719.0 SHIELDED COUPLINGS SHOCK ARRESTER, DEFINITION . . SHORTTURN 1 /4 BEND, PROHIBITED SHOULD, DEFINITION SHOWERS Approved standards . . . . Control valves Finished curb or threshold Gang Materials Vents SEWAGE EJECTOR SEWAGE PUMP SEWERS Abandoned Adjacent to walls . . . . Available Building, definition . . . Building, material of . . Cleanouts Connection to, required Construction of 408.1 408.3, 601.2 408.5 209.0, 408.3.1, 408.3.2, L 201.0, L 402.6.1 Mobile home and recreational vehicle parks Pans Public floors Receptors Stall or compartment Tests Valve and head location . . . E 501.7 408.7 408.8 408.5, 408.6, 408.7 408.6 408.75 408.9 2021 UNIFORM PLUMBING CODE 447


INDEX Valves Waste outlet or drains Water consumption . SHUTOFF VALVES Fuel gas . . .4172, 417.3 . .317.1, 408.4 408.2, L 402.6 Grease interceptors 1014.2.1, Table 1014.2.1 , 1014.3.6, Table 1014.3.6 313.6 801.3.1, 803.3 Hanger rods Indirect waste pipes Leaders, conductors, and storm drains . . . .5078, 509.5.71, 1200.13, 1210 3.3.1r 1210.8.2, 1210.11, 1212.3.1, 1212.3.2,1212.5.3, 1212.6, 1212.7 1212.9, 1213.2.5, 1213.6.1.4, E 402.3, E 402.4.2, E 403.0, E 403.9, E 403.13, E 404.5 1103.0, Table 1103.1, Table 1103.2, Table 1103.3 . . .506.8 .1323.1.1 1504.6. 2 E 403.12 Table 707.1, 70710 . . .1602.6,K 106.5 Louvers, grilles, and screens Medical gas and medical vacuum pipe Mulch basins Oil tanks Pipe cleanouts Rainwater catchment systems Reclaimed (recycled) water piping Roof drainage Medical gas and medical vacuum 1314.6, 1314.7 1314.8, 1314.11, 13272, 1310.3.2, 1312.2 . . . 710.12.1, 710.13.2 . .504.6, 606.2, 606.3, 608.4, 609.9, E 302.3, L 402.3.1, L 404.6, L 410.3, L 413.4 1502.6 1101.12, Table 1103.2, ’ able 1103.3, 1105.1, 1603.16, Appendix D, K 106.4 .1016.3 H 301.0 H 201.0 C 6O1.0 .1504.7 702.1, Table 702.1, 910.4, 1003.3, 1O06.1, 1101.15.2 C 501.2.1 Sewage Water . Sand interceptors Seepage pits and disposal fields Septic tanks . Single-stack vent systems . Subsoil irrigation field piping Traps SINGLE-FAMILY DWELLING, DEFINITION . SINGLE-STACK VENT SYSTEMS SINKS 221.0 C 601.0 420.0 420.1 205.0,413.1,1303.7 421.0, B 101.2 909.1 420.4 405.3, B 101.2 420.4 406.2 1001.2 Approved standards Clinical Floor island Laundry Prohibited types . . . Service Special use Three-compartment Vacuum drainage systems Vent pipes .Table 703.2, 710.10, 810.1, Table 810.1, 904.0, 908.1.1 , 908.1.2, 908.2.2, C 401.0 501.1, Table 501.1(1) 610.0, Table 610.3, Table 510.4, Table A 103.1, Appendix A, E 302.2 Water heaters . Water piping . . SIZE OF Water softener connections Wet venting SLAUGHTERHOUSES SLIP JOINTS 611.4 Building sewers Cesspools Chimneys Circuit venting Combination waste and vent piping Combustion air openings Condensate pipe Disposal fields Drainage piping 703.2, 7170, Table 7171 Appendix H 509.5.5 911.0 908.0 1010.0 221.0, 402.10, 509.10.9, 605.14, 705.9.1, 705.9.3, 1003.2 (see Grade) 221.0, 310.2, 310.4, 402.6.1 , 402.6.3, Table 701.2, 701.2(6), 722.2, 1002.4 H 101.2 7017, Table 701.7 212.0, 309.2,Table 313.3, 402.6, 605.1.3.1, 605.1.4, 605.16.1 , 705.3.3, 705.10.1, 705.10.2 910.0, Appendix B 506.3 -506.5 . . . .814.3, Table 814.3 Appendix H . . . Table 702.1, 703.0, Table 703.2, C 304.0, E 302.2, E 504.4 1015.3 1208.4, 1214.0, 1215.0, E 403.2,Table E 403.2 509.6.2, 5097.4, 509.10.2, 510.0 610.10, 610.11 1503.8 SLOPE SOIL PIPE SOIL POROSITY SOLDER, BUSHINGS SOLDER JOINTS . . . FOG disposal systems . Fuel gas piping systems SPACING Fuel gas vents Pipe supports 313.0, Table 313.3, 1210.3.5, 1210.3.5.1,Table 1210.3.5.1, 1323.4, Table 1323.4.4, 13276, Table 13276 Flushometer valves and tanks Gray water 448 2021 UNIFORM PLUMBING CODE


INDEX Subsoil irrigation fields Trenching and leaching beds SPECIAL FIXTURES SPECIAL VENTING SPECIAL WASTE PIPE SPECIAL WASTES Acid Chemical Definition Industrial High temperatures Laundries, slaughterhouses, bottling establishments, and auto wash racks SPECIFIC GRAVITY, NATURAL GAS SPECIFICATIONS FOR MATERIALS STACKS 1504.7.3 H 601.9 406.0 909.0 (see Industrial wastes) S-TRAP PROHIBITED STREET MAIN: (SEE WATER MAIN) 225.0, 608.1, 608.3, 610.7 Table 721.1 T Table 1503.4, A 104.2, A 104.4, Table H 101.8 1004.1 STRUCTURAL CONDITION SAFETY SUBMITTAL OF PLANS 811.2 811.0 221.0 811.0 810.1,Table 810.1 312.2, 312.11 103.3,104.3, 104.3.2, 104.3.3, 301.5.3, 811.1 , 910.2, 1105.1, 1304.3, 1505.2.1, 1602.2, C 301.1 , C 501.1, E 101.2, H 501.1, K 101.3.1 221.0, 1101.4.6, Table 1101.4.6, 1101.6, 1101.8, 1101.9 711.0, 1010.0 - 1013.0 SUBSOIL DRAINS 1214.1 SUBSOIL IRRIGATION FIELDS 301.2, Table 1701.1 221.0, 317.1, 706.2, 711.1, 906.1, 907.0, 911.3, 1101.16.2, C 304.3, C 304.4, C 401.0, C 601.0 Table 313.3,Table 604.1, 605.13, Table 701.2, 705.7 221.0, 1503.2.1, Table 1503.4, 1503.9.3, 1504.2, 1504.5, 1504.7, Table 1504.73 SUBSTITUTE MATERIALS 301.3 SUBSURFACE DISPOSAL FIELDS . . . SUBSURFACE IRRIGATION FIELDS . . . STAINLESS STEEL PIPE .1504.0, H 101.2 STANDPIPE, CLOTHES WASHER STATION INLETS AND OUTLETS . 221.0, 1503.2.1, 1504.2 - 1504.4, 1504.5 804.1 SUDS RELIEF SUMPS 711.0 221.0, 1305.3,Table 1305.3, Table 1323.1.5( 1), 1323.1. 2, 1315.0 Boiler room,installation . . Building, backwater devices Building drainage systems below sewer level Condensers Construction Definition Macerating toilet systems . Pump connection permitted 810.1, 810.3 STEAM EXHAUST CONDENSER OR BLOW OFF STERILE EQUIPMENT . . . STORAGETANKS Alternate water sources Hot water 710.1, 710.3, 710.4, 710.6 810.0,Table 810.1 806.0 710.2 . . .810.0, Table 810.1 810.2 221.0 710.13.1 .710.2 - 710.5, 710.9, 805.1, 1101.6.2, 1101.7 1503.3, 1505.4, 1506.4 505.2, 608.6, 6087, L 502.2, L 503.3.2, L 503.3.7 E 502.7 1602.73, 1603.0, K 102.2, K 103.3, K 105.0 C 501.2.1 Chapter 11, Appendix D 221.0, 1101.4.4, 1101.6, 1101.11, 1101.12, 1101.13, 1101.15, 1103.0, 1104.1 221.0, 715.3, 1101.2, 1101.4.5, 1101.12.2.2.2, 1101.13.1, 1103.2, 1104.1 Potable water . Rainwater . . . Pump discharges, conversion to fixture units Sewage Sizing, sewage ejector and pumps Storm drainage Vacuum drainage STORM DRAINAGE SYSTEMS STORM DRAINS 702.3, 710.5 710.2 710.3 1101.6.2, 1101.6.3, 1101.7 1101.10, 1101.11, 1101.14 .710.7, 710.10, 710.13.3, 810.1, Table 810.1 603.5.5 STORM SEWERS Vents STRAINERS AND CONNECTIONS Water supply inlets SUPPLY, WATER Fittings, fixtures . . 407.5, 408.4, 810.4, 1012.1, 1102.2 402.7 2021 UNIFORM PLUMBING CODE 449


INDEX Fixture, definition Fixture units . . . 208.0 610.3, Table 610.3, 610.7 -610.10, Table 610.10, Table A 103.1, C 303.2, C 501.5, E 302.1, E 302.2, E 302.2.2, L 402.3.1 601.2.1, 602.1, 603.4.5, 603.5.10t 608.7, 609.1, 609.4 T 610.3 T Table 610.3, 610.12.1, 610.12.2, Table A 103.1, A 105.3, Table C 303.2, L 502.5, L 502.7 L 502.7.3 604.0,Table 604.1, 1503.9.2 - 1503.9.4, 1505.6, 1506.6, 16027, K 103.4 601.3,603.571, 1506.6 610.0 T Table 610.3, Table 610.4, Table A 103.1, Table C 303.2, Appendix M 409.5, 410.2, 412.2, 414.2, 419.3, 602.0, 603.0, 1303.5, 1503.3, 1505.4, 1506.4, 1602.4, E 502.3, K 101.9, K 102.2, L 411.2 . . . .608.0, 1603.14, A 104.3, E 302.2.3, E 502.5, K 105.11 601.2, 1501.7, 1506.7 1506.9. 2, 1601.7, 1603.5, 1603.16, E 302.1, K 101.7 K 104.3, K 104.4 413.1 - 413.4, 416.2, 419.3, 610.3, E 302.1 408.10, E 302.2 603.5.5, 608.1 609.4 606.0 . . . .221.0, 313.0, Table 313.3, 402.4, 507.3, 507.3.1, 507.4, 50719, 509.5.8, 509.6.4, 509.7.5, 509.10.8, 609.1, 718.2, 906.4, 1208.7.2, 1208.15.1, 1210.3, 1210.3.5, Table 1210.3.5.1, 1323.4, 1323.4.4, Table 1323.4.4, E 402.4, E 404.2, F 901.4, H 601.3, L 501.2 SURGE TANKS SWIMMING POOLS, SPAS, AND HOT TUBS 221.0 603.5.5, 603.5.20, 813.0, L 4071,L 503.3.6 SYSTEMS Chimney venting Circuit venting Combination waste and vent 509.5.5, 509.6.2.4 911.0 205.0, 910.0, Appendix B 105.3.1 603.5.18.1 509.6.1, 509.8.2 206.0 509.10.7.1, 912.0, C 201.1 50722, 509.3. 4, 509.6.1 603.5.14 Hot water Defective, testing of Dialysis water Direct-vent Durham, definition . Engineered Exhaust Materials Fire protection (protection from) Firefighter breathing air replenishment Firestop FOG disposal . . . . Fuel gas piping . . Nonpotable water Pipe, size of . . . Appendix F Chapter 14 1015.0 507.18, Chapter 12, E 401.0 - E 406.4 509.0, Table 509.4, 510.0 601.3.3,1502.0 311.0 1211.5 710.13 509.3.3, 509.8, 509.10.3.2, 509.10.6 Potable water, protection Fuel gas venting . . Gray water Independent Lightning protection Macerating toilet . Mechanical draft . . Pressure Quality Medical gas and medical vacuum . . Natural draft venting . . . . On-site treated nonpotable Plumbing vent, definition . Plumbing venting Potable water (definition) 319.0, Chapter 13 509.6.2.1 601.3.3,. 1506.0 218.0 7107, Chapter 9r C 401.0 Quantity Risers . . . . Tanks, water Testing Valves SUPPORTS . 218.0, Appendix A, E 302.1 - E 302.8 713.2, 713.3, 713.5r 714.0, 716.1, 723.1r 904.1, Appendix H 603.5.18 220.0, 601.3.3, Chapter 16, Appendix Kr L 501.0 601.3.3, 1503.3, 1505.0, 1506.4, 1602.4 Chapter 7 E 301.0 - E 301.4.1, E 504.1 - E 504.5 C 601.0 612.0 Private sewage disposal Pure water process . Rainwater catchment Reclaimed (recycled) Sanitary drainage SURFACE WATER, DISCHARGE 306.2, 714.2, 811.1, 1101.1, 1101.11 Single-stack vent Sprinkler 450 2021 UNIFORM PLUMBING CODE


INDEX Storm water drainage . . . Ultraviolet water treatment Chapter 11, Appendix D . .Table 611.1r 1506.9.2, K 104.4.2, N 105.1 C 501.0 506.1.3, 506.7.3 908.2.5 Alternate materials and methods Building sewer 301.3 102.4.1T 105.2.1 T 105.2.1.2, 723.0 . .105.3, 11072.3 712.1 1213.0 .318.0+ 1203.3. 2 .1504.3, H 401.0 105.3 105.2.5 408.75 1106.0 .301.3.1.1, 505.4, 610.2, 1406.4 . . .609.4, 712.2, 1107.2.1, 11072.3 .105.2.1.1, 609.4 . . .605.1.5, 605.2.3, 605.5.2, 605.11.3, 605.12.3, 605.16.1, 705.1.3, 705.3.4, 705.4.2, 705.6.3, 705.10.2, 1208.6.9, 1208.6.10.1, 1322.5 Vacuum drainage Ventilation Wet vent Exceptions . . . . Final Fuel gas piping . Gauges Percolation Required Responsibility for Shower receptors Storm drainage . Testing agency . — T — T RATING .222.0, 1404.3, 1405.3, 1406.4 TAILPIECES Connection Definition Maximum length of Sizes . . 414.3, 419.2, 910.5, 910.6 222.0 910.5, 1001.2 . . 407.5, 408.4, 409.2, 420.4, B 101.3, B 101.5, B 101.6.1 Water TANKS Water supply systems Dosing . . THREADED JOINTS Expansion Flush . . . H 601.8 608.2, 608.3, 812.1 208.0, 402.4, 413.1, 601.2, A 104.1 610.11, A 106.3 608.3, 608.6, 608.7, L 502.2, L 503.3.2 710.8, 810.2 1017.1 T E 403.12, E 403.13, E 404.6 1602.73, 1603.6, K 102.2, K 103.3, K 105.0 1505.4 714.3, 716.1. 722.2 - 722.4, Appendix H 710.2, 710.7 -710.10, 810.2, 1101.7 221.0, 1503.2.1, Table 1503.4 1503.9.1, 1504.10 603.5.2 404.2, 405.1, 601.2, 603.5.2, 603.5.3, L 402.2 608.1, 608.6, 608.7t E 5027, E 506.1 Flushometer Hot water storage THREE SINGLE COMPARTMENT SINKS TOILETS TOILETS,FAMILY OR ASSISTED - USE FACILITY TRACER WIRE TRANSITION GAS RISER TRANSITION JOINTS TRAPS Arms 1001.2 Materials (see Water closets) Oil Rainwater storage 422.1.1 604.10. 1, 1210.1.72 . . . .222.0, 1210.4. 4 705.9. 4 Chapter 10 . .222.0, Table 702.1, 707.14, 1002.2, Table 1002.2, 1002.3 801.4, 902.2 1008.0 1004.1 810.1 222.0, 409.6, 905.5, 1001.2, 1002.2, 1002.4 222.0 1004.1 704.3, 1003.1, 1006.0, 10071 418.4, 801.3. 2 Reclaimed water storage Septic Sump or receiving . Bar and fountain sinks . Building Bottle Condensers and sumps Crown weir Surge Urinal . . . . Water closet Water supply Definition . Drum . . . . TEMPERATURE AND Floor drains PRESSURE-RELIEF VALVES TEMPERATURE-LIMITING DEVICES .504.6, 505.2 407.3, 408.3, 409.4, 410.3, 504.5 1207.0 . . . .509.6.1, 509.8 509.8.2, 906.0, H 501.11 Food storage areas . . . . For three-compartment sinks or three lavatories From fixture, distance of . From vent, distance of . . . Gray water system Grease interceptors Indirect wastes Integral TEMPORARY USE OF GAS TERMINATION OF VENTS 1001.2 1001.2 1002.2, Table 1002.2 1503.9.6 1014.1.1 803.3 1001.2 TESTS Air .105.3, 105.3.1, 609.4, 712.3, 723.1, 1107.2.2, 1107.2.3, 1213.1.6 2021 UNIFORM PLUMBING CODE 451


INDEX Island sinks Materials Minimum size . . Nonwater urinals Prohibited types . Required Seal 909.1 8072, 906.6, 1003.1 .702.1,Table 702.1, 1003.3 412.1.1 1004.0 1001.0, 1101.15 222.0, 412.1.1, 912.2, 1005.0, 1007.1, C 601.1, E 501.6 222.0, 1007.1 1001.2 705.9.1, 1003.2 804.1 1101.15 315.1 702.0,Table 702.1, Table 703.2 C 501.0 . Table 703.2, 810.1, 901.0, 905.2, 905.5, 908.2.1, 909,1, 1002.0, Table 1002.2 Fuel gas piping 1203.2, 1208.6.3.3, 1208.6.4.4, 1210.1, E 401.2, E 402.2, E 403.7, E 403.8, E 403.8. 4 Gray water piping 1503.9.2 Medical gas and medical vacuum piping Stop-and-waste valves . Storm water piping . . . . Tanks 1323.2, 1323.5.1 603.5.17 1101.4, 1101.4.2 1503.9.1, 1601.11.2, 1603.9, E 403.11,K 105.0 315.1 903.1, 903.2 . . . .604.3, 609.9, 1506.9. 4 Seal primer Separate for each fixture Slip joints Standpipe receptors . . . Storm drains and leaders Unions Unit loading Unions . . . . Vent material Water piping UNIONS Dielectric Fuel gas piping Location Medical gas and medical vacuum piping Sump pump Where allowed UNIT LOADING OFTRAPS . UNITS,FIXTURE UNLAWFUL CONNECTIONS UNSANITARY, DEFINITION URINALS 605.15, 605.16.1, 605.16.3 1212.6, E 404.2 315.1, 609.5, 710.6 Vacuum drainage system Vents for 1322.7 1101.6. 2 315.1 702.1, Table 702.1(1) (see Fixture, units) 404.2, 602.0, 1205.2 223.0 .402.5, 402.6, 405.2, 412.1r 413.0, 418.3, 601.2, 603.5.1, 603.5.2, 7074, 710.3, 910.7 1003.1,. 1014.1, 1014.3.2.1, 1501.9, 1505.1, 1506.1, 1506.9.2, 1506.9.5, 1602.1, 1603.14, 1603.19, 1604.2, E 501.2, E 501.5 T K 105.11 L 402.3 .301.3 223.0 TRENCHING, EXCAVATION, AND BACKFILLING 314.0, 1203.2, 1210.1.1 - 1210.1.2.1, 1323.5.1 TROUGH URINALS PROHIBITED TUBING, COPPER 405.2 . . Table 604.1, 604.3, 604.4, 605.1, 609.1, 609.3, 701.2, Table 701.2, 903.2, 1208.6.4.3, A 105.2, E 403.5 TUNNELING 314.2 TYPE B GAS VENTS . . . .224.0, 509.1, Table 509.4, 509.5.5, 509.6.1, 509.6.2.1, 509.6.2.2, 509.6.3.2, Table 509.73. 4(1) T 509.7.3.5, 509.10.1.1, 509.10.1.2, 509.10.7.2, 509.10.12 T 510.1.6, 510.1.10, 510.2.2, 510.2.15, 510.2.19, 510.2.20, 510.2.22, Appendix G . . .224.0, Table 509.4,509.6. 1, 224.0, Table 509.4, 509.6.1, 509.6.2.2, Table 509.7.3.4( 1), 509.10.1.1, 509.10.1.2, 509.10.12 USE OF ALTERNATE MATERIAL USER OUTLET, DEFINITION -V - VACUUM BREAKERS 224.0, 412.2, 601.3.4, Table 603.2, 603.3.2, 603.3.5, 603.3.6, 603.4.4, 603.5.1, 603.5.5, 603.5.6, 603.5.7, 603.5.9, 603.5.13, 603.5.15, 603.5.16, 1303.5, C 501.3, E 505.4, E 506.1 C 501.0 .224.0,504.6, 608.7, 1602.9 TYPE BW GAS VENTS TYPE L GAS VENTS VACUUM DRAINAGE SYSTEMS VACUUM RELIEF VALVES -U - UNDERGROUND Backflow prevention devices Building storm drains Drainage piping 603.4.9 1101.4.4 701.2, Table 701.2, 720.0 VACUUM SYSTEM - LEVEL 1f DEFINITION VALIDITY OF CODE 224.0 101.5 452 2021 UNIFORM PLUMBING CODE


INDEX VALVES Shutoff 504.6, 606.2, 606.3, 606.6, 608.4, 609.9r 612.4.3, 612.6, 710.12.1, 1202.1, 1203.3. 2, 1208.12, 1208.13, 1210.3.3.1, 1210.8.2, 1210.9 - 1210.9. 4, 1210.11, 1210.12.5, 1212.3.1, 1212.3.2, 1212.5.3, 1212.6, 1212.7, 1213.2.5, 1213.6.1.4,. 1310.3.2, 1312.2, 1314.6, 1323.14, 13272, 1503.9.1, E 302.3, E 402.3, E 402.4.2, E 403.0, E 403.9, E 403.13, E 404.5, E 505.4, E 506.1, F 601.1, K 105.4, L 402.3.1, L 404.6, L 410.3, L 413.4 224.0, 1314.6, 1314.7, 1323.14.2, 1324.5. 4.2 504.5, 504.6, 505.2 222.0, 408.3 C 501.2.4 224.0, 504.6, 607.5, 608.7 1505.10, 1506.9.3, 1602.9 224.0, 1314.4 Chapter 9 905.5, 1002.4 204.0 Backwater 204.0, 710.1, 710.3, 710.6, 1006.1, 1503.2.3, 1503.9.1, 1503.9.7, 1603.10, K 105.4 606.1, 606.4, 710.4, 710.6 409.5 . . .603.5.10, 608.3, 710.4, 710.12.1.710.13.2, 1004.2, 1208.12.1, 1309.11, 1311.5, 1313.5, F 701.3 603.5.17 Ball Bathtub filler Check Combination stop-and-waste Combination temperature and pressure-relief Combination thermostatic/ pressure balancing Control 505.2, 608.3 205.0, 408.3 408.9, 601.2, 606.5, 606.6, 1303.1, 1306.2, C 501.3 .50722, 1208.8.4, 1208.12 2070, 1209.0 L 501.7 208.0 . . . .208.0, 411.2.2, 413.1, 413.2, 601.2, 603.5.1, 610.10, Table 610.10, A 104.1, L 402.2.2 606.2, 710.6 . . .606.1, 606.4, 710.3, 710.4, 710.6 209.0, 1503.2.2 310.7 224.0, F 501.7, F 601.5.1, F 701.3, F 801.6 4175 420.3, L 201.0, Table L 402.1, L 402.8 218.0, 408.3 612.5.3.2.2, 612.72, 1504.5.7 1603.14,A 107.2, E 403.13, F 701.3, K 105.11 504.4, 504.6, 505.2, 5079, 607.5, 608.2 - 608.6, 1208.11 4, 1306.2 1308.2, 1308.3, 1309.5, 1310.3, 1310.4, 1315.15, 1316.1, 1324.4, 1324.5, 13277.1, E 302.5, E 302.6, F 501.8, F 701.3 609.11 224.0, 1314.8, 1323.14.4 224.0, 1314.9, 1323.14.5, E 402.4.2 Source Temperature relief Thermostatic . . . Vacuum interface Vacuum relief . . . Diaphragm-type Excess flow . . . Flow balancing Flush, definition Flushometer . . Zone VENT, PLUMBING Below trap weir Branch, definition . . . . Buildings over 10 stories Changes in direction of Chemical . Combination waste and vent system design . . Fullway Gate Gray water divei ter Installation Isolation 9071 903.3 811.2, 811.5, 811.6 205.0, 910.0, Appendix B 310.2, 805.0, Table 810.1, 905.1, 905.2, 908.1.2, 908.2.1, 911.2, 1503.2. 2 205.0 224.0 . . . .1002.2, Table 1002.2 704.2, 905.6 912.0 .705.9.2, 1101.5, 1213.2. 2 .701.2, Table 701.2, 903.1 704.2, 905.6 906.3 312.8, 701.5, 906.1, 906.5, 906.6 906.7 905.1, 905.3, 911.4 905.3 906.4 Mixing Pre-rinse spray Connections Pressure-balancing Pressure-reducing Continuous, definition Definition Distance of trap from Double fitting for . . . . Engineered Expansion joints . . . . Fittings Fixtures, back-to-back Flagpoling, prohibited Flashing for Pressure-relief Quick-acting Riser Frost or snow closure Grade of Height above fixture Service Height above grade . 2021 UNIFORM PLUMBING CODE 453


INDEX Horizontal Indirect waste . . . . Individual, definition Interceptors Table 703.2, 904.2, 905.3 803.3, 805.1, 902.1 211.0 902.1, 1009.4, 1014.1.1, 1014.2.2, 1016.4, 10171 909.0 Table 702.1,Table 703.2, 904.0 701.0f Table 701.2, 811.2, 903.0, 1503.9.2 . . . .310.5, 903.3, 906.2, 906.4 902.0 WASH RACKS, AUTO WASTES Anesthetic gas disposal Chemical Clear water Condensate Continuous 1011.0 1301.2 . . . .205.0, 811.0, 903.2.2 205.0, 812.0 807.2r 814.0 205.0, 4075, 408.4, 409.2, 419.2 808.0 225.0 . . . .305.1, 306.1, 714.1, 811.1, 1009.1, H 901.1 1009.1, H 901.1 . . . Chapter 8, 1303.4.1 211.0, 306.0, 801.1, 811.1, 903.2. 2 214.0, 303.0, 304.0, 710.2, 811.1, 1006.1, 1009.1,H 101.3, H 701.1, H 901.1, L 302.0 701.1, 811.2 225.0 811.1, 1014.1 1013.1 221.0 813.1 island sinks and fixtures Length of Material for Cooling water Definition Detrimental or harmful Method of installation Not required Not to be used as soil or waste pipe . Opening location . . Parallel Piping, support of . . . Prohibited 310.4 905.5, 1002.4 Flammable Indirect . . Industrial 907.1 Table 313.3 310.4, 903.1, 903.2.2 220.0, 805.0, 9070, 911.3, 1009.4 901.2, 904.1 Refief Liquid Required Required separately on every trap . . . Sizing 901.2, 1002,1,1002.2 Table 702.1, 703.0, Table 703.2, 904.0, 908.1.1, 908.1.2, 908.2.2, 910.4, C 401.0, Table C 401.1, C 601.2 909.0 224.0, 906.1, 907.0, C 401.2, C 601.2 710.7 710.10, 710.13.3, 810.1, Table 810.1 224.0 . .905.4, 906.0 712.0, 1504.10 . .901.3, 1002.0 Materials, pipe Pipe, definition Pretreatment required Process Special, definition . . . Swimming pools . . . Special . Stack . . . WATER Sump Backflow prevention Cross contamination Table 603.2, 603.3 601.2, 602.2r 603.1 - 603.3.10 604.1, Table 604.1 System, definition Termination Testing Trap seal protection . . . . Undiminished in size through roof Unit loading Wetr Horizontal Wetr Vertical Yoke VENTILATING HOODS VERTICAL-TO-HORIZONTAL DRAINAGE FITTINGS . . . VERTICAL WET VENTING VIOLATION, NOTICES OF . . VITRIFIED CLAY PIPE Distribution piping material Distribution system design Excessive pressure Hammer Identification Lead content Nonpotable 601.1 608.2 609.11 601.3 604.2, 604.2.1 . . .603.5.11, 1506.6, 1506.9.5, L 408.1 1101.4 1602.4 (see Storm drainage) . . .604.1, Table 604.1 . . . .905.4, 907.1 . . . Table 703.2 908.2 908.1 . . . .2270, 907.0 509.2.4, 509.3.4 Rainwater, material Reclaimed Storm water Supply piping material . . . Treatment units WATER CLOSETS Approved standards Clearance Compartments Flanged fixture Connection Floor-mounted, back-outlet Seats 706.4 (see Wet vents) 106.2 701.2, Table 701.2, 705.8, 811.2, Table 1101.4.6 611.0 411.0 411.1 402.5 E 501.3.2, E 501.3.3 402.6 402.6.3 411.3 -W - WALL, EXTENSION THROUGH WALL-HUNG FIXTURES, INSTALLATION OF 312.1, 509.6. 1, 509.8 402.4, 402.6 454 2021 UNIFORM PLUMBING CODE


INDEX Manufactured/Mobile home .E 501.2, E 501.3, E 501.3.1, E 501.6 . . . .405.1, 910.7 . . . 411.2, L 402.2 Tanks . . 714.5 T 1503.9.1 , 1504.10, 1603.3, H 501.3, H 1001.2, K 105.2 C 501.8 Prohibited Water consumption WATER-CONSERVING FIXTURES AND FITTINGS . . WATER HAMMER ARRESTORS WATER HEATERS Access Vacuum drainage systems WATER/WASTEWATER UTILITY, DEFINITION WEEP HOLES, SUBDRAIN OF SHOWER STALLS WEIGHT OF FLASHING, LEAD WEIGHTS AND QUALITY OF MATERIALS L 402.0 . . . .225.0, 609.11 Chapter 5 504.3.1, 50713.2, 507.26, 508.4 225.0 408.7 701.5, 906.6, 1102.3.1 Approval requirements Approved standards . Clearances 501.1 301.2, 401.2, 604.1, 701.2, 906.6, 1102.3.1 .212.0, 605.13.2, 705.72, 1208.6.10.1, 1208.6.10.3, 1322.1, F 1101.2 225.0 Table 501.1(1), 505.3, 505.4 504.3 - 504.3.2, 508.1, 508.2.1 506.0 604.13 225.0 50713 503.2 507.0 504.1, 507.12 - 50715 505.0 502.0 504.4, 504.6, 505.2, 608.2 -608.5 504.3 -504.6, 505.2, 507.2, 5078, 507.10, 507.14.1, 507.25 608.5 .5072 WELDED JOINTS Combustion air required Connectors Definition Garages Inspections Installation Location Oil-burning and other . Permits required Pressure-relief valves . . WELDER, PIPE,DEFINITION WELL,DISTANCE FROM SEWAGE DISPOSAL . . . . 721.1,Table 721.1, H 101.8, Table H 101.8 908.0 225.0 908.2.3, 908.2.4 . .908.2, B 101.2, C 601.6 908.2 908.1 225.0, 409.0 WET VENTS Definition Fixtures Horizontal Vent connection Vertical WHIRLPOOL BATHTUBS WINDOW,TERMINATION OF VENTS FROM WOODEN SINKS ANDTILE WASHTRAYS OR SINKS WORK,CONCEALED Protection . . . Relief valve discharge Seismic provisions Temperature and pressure-relief valves . . . Temperature-limiting devices Vents WATER SOFTENERS WATER TESTS Building sewers Drainage and vent systems . Storm drainage Water supply systems WATERPROOFING AND WATERTIGHT Building sewer . . Cleanouts Connections . . . Drain pans Fixtures Flashings Interceptors . . . . Joints 906.2 405.3 105.0 - 105.2.1.2, 309.2r 402.10, 503.0 - 503.2, 509.73.2, 1004.1, 1203.2, 1203.3, 1210.4, 1212.3.1f 1212.5.3, 1213.2.1 , 1303.2, 1323.6 T 1406.1 102.2, 102.4, 2070 . .309.0, 609.1, 1208.6.8 609.3r 1210.3, E 403.6 504.6, 505.2 504.5 509.0, 510.0 611.4, Table 611.4 723.0 105.3, 712.2 11072.1 T 11072.3 105.2.1.1, 105.3, 609.4 WORK, EXISTING WORKMANSHIP . . . WRAPPING OF PIPE 723.1 707.3 105.3 507.5 402.2, 408.5, 408.7 418.2 312.8 T 906.5, 1102.3 1016.3 105.3, 1504.7.3, H 601.4, H 601.6, H 601.7, H 601.10, H 801.4 312.8, 312.10.2, 317.1 710.2, 710.8 WROUGHT IRON (GALVANIZED) 402.6.1, Table 604.1,604.6, 604.7, 701.2, 7071, 1101.4, 1208.6.3.1, 1208.6.10.5, E 403.5 414.3, 419.2, 706.2 - 706.4, 707.5, 7076, 710.4, 719.4, 9072, 909.1, 1101.16. 2 WYE CONNECTIONS Openings Sump or receiving tanks 2021 UNIFORM PLUMBING CODE 455


INDEX - X - X-RAY DARKROOMS 011.8 -Y - YOKE VENTS 2270, 907.0 -ZZINC ALLOY COMPONENTS 406.4, 1208.6.10.5 456 2021 UNIFORM PLUMBING CODE


LICENSE AGREEMENT INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS (1APMO) UNIFORM PLUMBING CODE E-BOOK -2U21 EDITION The International Association of Plumbing and Mechanical Officials (“IAPMO’ 1 ) agrees to grant, and the user of the eBook agrees to accept, a nonexclusive license to use the eBook under the terms and conditions of this eBook License Agreement (“Agreement"), Your use of the eBook constitutes your agreement to the terms and conditions set forth in this Agreement. This Agreement, or any pait thereof, cannot be changed, waived, or discharged other than by a statement in writing signed by you and 1APMO. Please read the entire Agreement carefully. eBook Usage The 1APMO eBook may be used by one user on one computer. The user of the eBook shall be subject to all of the terms of this Agreement, whether or not the user was the purchaser. Copyright, Use and Resale Prohibitions IAPMO retains all rights not expressly granted to you in this Agreement. The software, content, and related documentation in the eBook arc protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. Nothing in this Agreement constitutes a waiver of IAPMO* s rights. IAPMO will not be responsible for performance problems due to circumstances beyond its reasonable control. Other than as stated in this Agreement, you may not copy, print, modify, remove, delete, augment, add to, publish, transmit, sell, resell, license, create derivum e works tiom. or in any wa \ exploit any of the eBook ’ s eon tern, in whole or in pait, in print or electronic form, and you may not aid or permit others to do so. The unauthorized use or distribution of copyrighted or other proprietary content is illegal and could subject the purchaser to substantial damages. Purchaser will be liable for any damage resulting from any violation of this Agreement. No Transfer This license is not transferable by the eBook purchaser unless such transfer is approved in advance by IAPMO, in which case the transferee will be subject to the terms and conditions of this Agreement. Disclaimer The eBook, or any support given by lAPMO' stechnical support staff, are in no way substitutes for assistance from legal, tax, accounting, or other qualified professionals. If legal advice or other expert assistance is required, the services of a competent professional person should be sought. Limitation of Liability The eBook is provided “as is” and IAPMO does not make any warranty or representation, either express or implied, to the eBook, including its quality, accuracy, performance, merchantability, or fitness fora particular purpose. You assume the entire risk as to the results and performance of the eBook. IAPMO docs not warrant, guarantee, or make any representations regarding the use of, or the results obtained with, the eBook in tcims of accuracy, correctness or reliability. In no event wall IAPMO be liable for indirect, special, incidental, or consequential damages arising out of delays, errors, omissions, inaccuracies, or the use or inability to use the eBook, or for interruption of the eBook, from whatever cause. This will apply even if IAPMO has been advised that the possibility of such damage exists. Specifically, IAPMO is not responsible for any costs, including those incurred as a result oflost profits or revenue, loss of data, the cost of recovering such programs or data, the cost of any substitute program, claims by third parties, or similar costs. Hold Harmless / Indemnification. You agree to defend, indemnify and hold IAPMO and any third party provider harmless from and against all third party claims and damages (including reasonable attorneys1 fees) regarding your use of the eBook, unless the claims or damages arc due to IAPMO' S or any third party provider 1 s gross negligence or willful misconduct or arise out of an allegation for which IAPMO is obligated to indemnify you. Termination If you materially breach this License Agreement, we may terminate your right to use the Material immediately upon notice to you.


You agree that, upon termination of the License Agreement, you will either return to us or destroy all copies of the Material in your possession. Additional Terms This written License Agreement is the exclusive agreement between you and us concerning the eBook and supersedes any and all prior oral or written agreements, negotiations, or other dealings between us concerning the eBook. This License Agreement may be modified only by a writing signed by the user and 1APMO. in the event of litigation between the user and IAPMO concerning the eBook, the prevailing party in the litigation and the prevailing party in any ancillary disputes (c.g., discovery disputes) will be entitled to recover attorneys ' tees and expenses from the other party. This License Agreement is governed by the laws of the State of California applicable to contracts executed and performed entirely in, and by residents of. that state. This License Agreement is effective immediately upon your installation or use of the eBook. If you have any questions regarding this License Agreement, please write to the International Association of Plumbing and Mechanical Officials (IAPMO), 4755 Last Philadelphia Street, Ontario, California 91761-2816. This agreement is governed by the laws of the State of California applicable to contracts executed and performed entirely in, and by residents of, that state.