2 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
PERIMETER BARRIERS Siderise CW perimeter barrier and fire stop systems
AND FIRE STOPS FOR offer an extensive range of solutions for fire stop, smoke
CURTAIN WALLING stop and sound barrier requirements in all architectural
cladding panel applications.
Based on the experience gained through being the
premier supplier to the UK curtain walling market, the
products represent an unrivalled combination of fully
qualified performance, practical installation and service
benefits.
The primary function of the CW system is to maintain
continuity of fire resistance by sealing the void between
the compartment floors or walls and the external
curtain wall both horizontally and vertically.
Canary Wharf, London
Front Cover: Dollar Bay, London
• No. 1 in the UK for over 30 years | 3VERSION 1.9 SEPTEMBER 2021
• Third-party approved options:
Benefits
Certifire & Intertek certification
• Fully compliant to: UK, EU & UAE regulations • Market leading fire resistance and smoke seal
• Fire Resistance to: EN 1364-4, EN 1366-4 • Suitable for horizontal and vertical application
• Classified ‘A1‘ to: EN 13501-1 • Unique product construction provides ability to
accommodate façade movement
• Fully qualified acoustic performance
• Simple and quick to install
4 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
PRODUCT DESCRIPTION
Siderise perimeter barriers and fire stops for curtain
walling use is a unique method of manufacture that
provides a resilient lateral compression. This facilitates
installation ensuring the requisite tight fit and enhances
fire integrity.
The materials throughout the range comprise of a one-
piece product with a pre-compressed non-combustible
stone wool core. The products also have integral
aluminium foil facings to provide an overall Class A1 rating
(to EN 13501-1) and excellent resistance to smoke.
The systems can offer tested fire rating options ranging
from 30mins to 3 hours and can accommodate void
widths up to 600mm.
In addition to providing an effective seal against the
passage of smoke and fire the products will also function
as an effective acoustic barrier and plenum lining.
Siderise Cavity Barrier (CW-CB) or Siderise Fire
Stop (CW-FS)
Metal spandrel panel with Siderise Nexus ‘Core’
Siderise Nexus ‘Fusion’
Insulation other than Class A1
Siderise Nexus or Class A1
Siderise CW-FB Curtain Wall Fire Board
Siderise CW-AB Acoustic Barrier Overlay
Siderise CVB/C Acoustic Void Barrier
| 5VERSION 1.9 SEPTEMBER 2021
Standard systems Fire performance Third party certification
The materials can be either supplied Reaction to fire Certifire Certification has been
as pre-cut units to suit a specified void achieved based on proven fire
size or in sheet form for cutting on Siderise CW Cavity Barriers and Fire performance, for horizontal
site. Stops have been tested for non- applications to EN 1364-4 (Table 1),
combustibility and classified ‘A1’ to EN and horizontal and vertical applications
Sheets 13501-1. to EN 1366-4 (Table 2 & 3).
• Standard sheet products are
Resistance to fire For further details, Certifire Certificate
supplied 1200 x 1200mm which may ‘CF 563’ can be downloaded from
prove beneficial when the actual Siderise CW systems have been tested www.siderise.com
void size is not known or where to EN 1364-4 and EN 1366-4 for fire
it varies significantly. Please note resistance, and classified to EN 13501- Intertek Certification has also been
when ordered in sheet form, the 2. achieved based on reaction to fire
requisite quantity of fixing brackets performance to EN 13501-1, and fire
needs to be purchased separately. Siderise CW systems provide resistance to EN 1364-4 for horizontal
continuity of fire resistance applications (Table 1).
Pre-cut Strips across the void when aligned with
• Pre-cut products are available in fire rated elements to maintain For further details, Intertek
compartmentation. Certificates ‘WH120-32944302’
1mm increments of width to suit the (EN 13501-1) and ‘WHI19-32944301’
cavity size. Please see Tables 1, 2 & 3 The correct system is simply selected (EN 1364-4) can be downloaded from
regarding ‘fit type’. by matching the fire resistance www.siderise.com.
requirements to the CW system type
• S upplied with appropriate brackets and void size.
as part of a system
Tables 1 to 3 summarise the void
The standard fixing brackets are sizes, fire resistance classifications
supplied in 1mm galvanised mild steel to EN 13501-2, and provide 3rd Party
in flat form that is complete with a pre- Certification details where applicable.
notched facility for folding on site.
Approved Document B – England &
All holes are to be drilled to suit the Wales
varying site conditions. Different size
brackets are available according to the Approved Document B for England
cavity size – please see Tables 1 to 3. & Wales (2019 edition) gives
classification to EN 13501-2 as the
All fixing brackets are to be mechanic- primary route to compliance.
ally secured to the substructure with
suitable non-combustible fixings. BS 476-20 remains as an alternate
route to compliance.
Siderise CW systems have addition-
ally been tested and assessed to BS
476-20. For any voids not covered by
Tables 1 to 3, please contact technical.
[email protected] for advice on
these options.
6 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Table 1: Fire Resistance to EN 1364-4* (Horizontal Orientation)
Void Product Product Compression Cover Bracket Classification 3rd Party Approval
Width Ref. Thickness (minimum) Length Requirement (EN 13501-2)
(mm) Certifire ‘CF 563’
(mm) 2 no. B65/110 EI 120 Intertek ‘WHI19-
20 to 50 600mm EI 180 32944301’
CW-FS120 120mm +10% 1200 centres EI 120 Certifire ‘CF 563’
51 to 150 CW-FS180 150mm 2 no. B65/110 EI 180 Intertek ‘WHI19-
600mm EI 120 32944301’
151 to CW-FS120 120mm +10% 1200 centres EI 180 Certifire ‘CF 563’
250 CW-FS180 150mm 2 no. B195 Intertek ‘WHI19-
600mm 32944301’
CW-FS120 120mm +10% 1200 centres
CW-FS180 150mm
NOTE: All fixing brackets are to be mechanically fixed to structure. Please see separate installation instructions.
Table 2: Fire Resistance to EN 1366-4 (Horizontal Orientation)
Void Product Product Compression Cover Bracket Classification 3rd Party Approval
Width Ref. Thickness (minimum) Length Requirement (EN 13501-2) Certifire ‘CF 563’
(mm) Certifire ‘CF 563’
(mm) None EI 30 Certifire ‘CF 563’
EI 60 Certifire ‘CF 563’
CW-CB30 75mm 2 no. B65/110 EI 120 Certifire ‘CF 563’
600mm EI 30
20 to 50 CW-FS60 90mm +10% 1200 centres EI 60
2 no. B195 EI 120
CW-FS120 120mm 600mm EI 30
centres EI 60
CW-CB30 75mm 2 no. B355 EI 120
600mm EI 30
51 to 150 CW-FS60 90mm +10% 1200 centres EI 60
2 no. B355 EI 120
CW-FS120 120mm 600mm
centres EI 60
CW-CB30 75mm
151 to 250 CW-FS60 90mm +10% 1200
CW-FS120 120mm
251 to CW-CB30 75mm +10% 1200
300 CW-FS60 90mm
CW-FS120 120mm
301 to CW- 120mm +10% 1200
600 FS60-X
NOTE: All fixing brackets are to be mechanically fixed to structure. Please see installation instructions.
| 7VERSION 1.9 SEPTEMBER 2021
Table 3: Fire Resistance to EN 1366-4 (Vertical Orientation)
Void Product Product Compression Cover Bracket Classification 3rd Party Approval
Width Ref. Thickness (minimum) Length Requirement (EN 13501-2) Certifire ‘CF 563’
(mm) Certifire ‘CF 563’
20 to 50 (mm) None EI 30 Certifire ‘CF 563’
EI 60 Certifire ‘CF 563’
51 to 150 CW-CB30 75mm +10% 1200 2 no. B65/110 EI 120 Certifire ‘CF 563’
CW-FS60 90mm 600mm EI 30 Certifire ‘CF 563’
151 to CW-FS120 120mm +10% 1200 centres EI 60
250 CW-CB30 75mm 2 no. B195 EI 120
CW-FS60 90mm +10% 1200 600mm EI 30
251 to CW-FS120 120mm centres EI 60
300 CW-CB30 75mm +10% 1200 2 no. B355 EI 120
CW-FS60 90mm 600mm EI 30
301 to CW-FS120 120mm +10% 1200 centres EI 60
450 CW-CB30 75mm 2 no. B355 EI 120
451 to CW-FS60 90mm 600mm EI 30
600 CW-FS120 120mm centres EI 60
CW-CB30 75mm 2 no. B355 EI 120
CW-FS60 90mm 600mm
CW-FS120 120mm centres EI 60
CW- 120mm +20mm 1200
FS60-X
NOTE: All fixing brackets are to be mechanically fixed to structure. Please see installation instructions.
8 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Acoustic performance As an example, the installation of which can further enhance the
120mm thick CW-FS120 within the overall acoustic performance of the
The CW range additionally provides an cavity will increase the transmission construction.
effective sound barrier as the material loss via the tortuous sound path by
construction and inherent properties approximately 25dB. AB barriers are extremely quick and
of the stone wool core afford the CW easy to install and are suitable for
exceptional acoustic performance. The precise value will depend upon improving sound performance within
the specifics of the construction. all curtain walling environments.
Also, the foil facings coupled with
the additional sealing of joints with Table 4 confirms values for Weighted The AB acoustic barriers are factory
Siderise foil tape all serve to provide Sound Reduction Index (Rw) based on produced multi-layer composite
improved air tightness. laboratory tests to determine airborne materials consisting of an aluminium
sound transmission in accordance with foil faced polymeric layer bonded to a
Sound reduction between floors BS EN ISO 140-3 : 1995, BS 2750 Pt 3 flexible acoustic foam. The products
The installation of the CW systems :1995. are available in two grades depending
within an external curtain wall cavity on the acoustic performance
will significantly increase the floor-to- Enhanced acoustic performance requirement, namely AB5 and AB10
floor attenuation. AB acoustic barriers whenever façade deflection is
Siderise offer a range of complementary anticipated.
acoustic mass overlay materials
Table 4: CW acoustic performance Table 5: AB acoustic performance
Weighted Sound Reduction Index Weighted Sound Reduction Index
Product Type Thickness (mm) Rw (dB) Product Type Surface mass (mm) Rw (dB)
CW-CB30 75 21 25
22 AB5 5 kg/m2 28
25
CW-FS60 90 26* AB10 10 kg/m2
CW-FS120 120
CW-FS180 150
NOTE: *Assessed values by either UKAS accredited Laboratories
or IOA registered Acoustic Engineers
Table 6: The table below illustrates typical CW and AB acoustic performance of a range of different curtain wall
fire stopping products, including products manufactured by Siderise.
Product 21 - 30dB Rw 31 – 35dB Rw 36 - 50dB Rw 50dB Rw +
Rw Rw
Siderise CW-FS60 Rw Rw Rw Rw Rw Rw
Siderise CW-FS120 + Ctr + Ctr + Ctr + Ctr
Siderise CW-FS60 + AB5 Overlay 23 21 — — — — ——
Siderise CW-FS120 + AB5 Overlay 25 23 — — — — ——
Siderise CW-FS60 + AB10 Overlay — — 33 27 — — ——
Siderise CW-FS120 + AB10 Overlay — — 33 27 — — ——
Siderise CW-FS120 + AB10 Overlay — — — — 36* 31* ——
+ CVB/C10 below — — — — 37 32 ——
Siderise CW-FS120 + 2mm Steel Plate Overlay —
+ CVB/C10/75 below —— —— — 51 45
—
—— —— — 53 45
NOTE: *Assessed values by either UKAS accredited Laboratories or IOA registered Acoustic Engineers
| 9VERSION 1.9 SEPTEMBER 2021
Siderise CW-FS120 Siderise CW-FS120 + AB10 Overlay Siderise CW-FS120 + AB10 Overlay
+ CVB/C10 below
Societe Generale, London
10 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
| 11VERSION 1.9 SEPTEMBER 2021
Installation recommendations Where the void is smaller than the Installation detailing
section available, the CW-CB/CW-FS
Siderise CW is installed using can be trimmed on site with a sharp For the interface with the mullion
necessary compression and fixing serrated knife providing that the condition we recommend that the
brackets (see tables 1-3) which are compression allowance is maintained. CW is trimmed to accommodate
impaled into the material at mid- Also, if used in sheet form, the product the mullion with the joint between
thickness at nominal 600mm fixing must be cut to provide the requisite adjacent product being along the
centres i.e. 300mm from each end. compression fit. centre line of the mullion.
For horizontal applications the cut Installation principles For curtain wall systems with mullion
strips are then inserted within the void centres in excess of 1200mm, we
with the fixing brackets located over The CW material must be installed recommend the use of standard
the edge of the concrete floor slab. with the un-faced stone wool in 1200mm CW-CB/CW-FS trimmed to
contact with the sides of the cavity, accommodate the mullion, together
The brackets must be mechanically the aluminium foil smoke barrier with a smaller section of CW-CB/
fixed to the compartment floor or wall, facings will be positioned top and CW-FS trimmed to accommodate the
with suitable non-combustible fixings. bottom i.e. remains visible to the mullion.
installer. For all installations the CW
The CW is built into the void to seals are to be sized to provide the Please note that the smaller 300mm
provide the necessary compression as correct compression allowance. See CW-CB/CW-FS length is secured with
per Tables 1 to 3. It’s crucial that there Tables 1 to 3. two fixing brackets. We specify that all
are no gaps. small portions of CW-CB/CW-FS are
Installation considerations fixed with two fixing brackets as part
Ensure that there are no gaps and that of the system.
all joints, including the intersections As standard, the CW material must be
of horizontal / vertical installation, compressed within the void to maintain For the interface with the spandrel
are tightly abutted and sealed with the integrity of the seal. panel at the mullion position we
Siderise foil tape to ensure the recommend the use of a cut portion
integrity of the smoke barrier. As a For vertical applications where the of CW product to suit the void (cut
minimum the topside is only sealed façade deflection may be up to 15mm, oversize to maintain compression).
with Siderise foil tape, the juncture we recommend that you calculate This is then bonded into position with
between façade and floor or wall need the design deflection of the external Siderise fire and acoustic gap sealant.
not be sealed. façade system in both positive and
negative wind load situations. Then Smaller voids and/or particularly
Fixing brackets follow Tables 1 to 3 + the design difficult situations can be treated by
deflection of the system. the additional application of Siderise
A range of support brackets for fire and acoustic gap sealant to make
Siderise CW-FS horizontal perimeter Additional material allowances good joints, areas of missing material
barriers are available for void widths should be included whenever façade or complex details.
of up to 600mm (see Tables 2 and 3 deflection is anticipated. For example:
for appropriate type and quantity). The CW material is easily cut on site
CW-CB/CW-FS + Deflection + with a sharp serrated knife to form
The fixing brackets should be trimmed Compression a tight resilient seal around mullion
if necessary to approximately 75% details and structural brackets etc.
of the cavity width. The standard CW-CB/CW-FS to suit void + 15mm
fixing brackets are supplied in 1mm + 10mm = CW-CB/CW-FS to suit void
galvanised mild steel in flat form that + 25mm
is complete with a pre-notched facility
for folding on site. Stainless steel Therefore for 120mm void = 120mm
brackets can be quoted and provided + 15mm + 10mm = 145mm of CW-CB/
upon request. All holes are to be CW-FS
site drilled to suit the varying site
conditions.
Dollar Bay, London
12 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Movement characteristics Design considerations
Curtain walling and external façade Important factors to consider for the
deflection application of fire stops within curtain
wall façades:
The qualification of proprietary fire
stop systems are typically limited • Review the position of firestop
by the condition that they must be and distance from fixing bracket
installed in a static environment. connection.
However, for curtain walling • E nsure structural engineer specifies
applications it is imperative that the façade defelction.
the installed seal is able to function
effectively with due regard to all • R eview the curtain wall expansion
designed movement serviceability and any floor slab/building movement.
limits. Siderise recognise that curtain
walling and cladding façade systems • Review transom/mullion deflection.
will deflect due to:
Upon confirmation and consideration
• Positive wind-load of the above parameters, the required
• Negative wind-load fire stop compression factor can
• Occupational live load be assessed for the specific project
application.
The above are covered by EN 13116:2001
Note 1: Siderise CW vertical fire
Typically, a project may stipulate that stop systems can accommodate
the curtain walling system may have the façade deflection due to their unique
following allowable deflection limits: construction. However, material size
is crucial to ensure that integrity is
Under the declared wind loads the maintained.
maximum frontal deflection of the
curtain walling’s framing members shall Note 2: On a project basis, consider
not exceed L/200 or 15mm, whichever both inward and outward deflection
is the less, when measured between requirements for the system.
the points of support or anchorage to
the building’s structure in compliance
with EN 13116. [Extract from EN 13830]
These factors may inevitably combine
to preclude the suitability and
therefore, use of certain systems e.g.
high density material slab products.
However, the CW perimeter barriers
and fire stop systems are very effective
in their function within curtain walling
as the unique material construction
can accept the cyclical negative and
positive wind and live loads imposed
on the façade.
| 13VERSION 1.9 SEPTEMBER 2021
The Scalpel, London
14 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Horizontal perimeter barrier installation: CW-FSH-01-A
Curtain Wall Fire Stop
Siderise CW-FS
75% Fixed Bracket Spandrel Panel
Siderise Bracket Siderise NXR Core
Fixed Bracket
Siderise Bracket 75% Spandrel Panel
Siderise NXR Core
Curtain Wall Fire Stop
Siderise CW-FS
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Siderise Nexus Core ‘NXR’
Horizontal perimeter barrier installation: CW-FSH—02—A | 15VERSION 1.9 SEPTEMBER 2021
Curtain Wall Fire Stop Fixed Bracket
Siderise CW-FS Siderise Bracket
Foil Tape Spandrel Insulation
Siderise FT 120/45 Non Fire Rated
Fixed Bracket Spandrel Insulation
Siderise Bracket Non Fire Rated
Curtain Wall Fire Stop
Siderise CW-FS
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Spandrel insulation (non fire rated)
16 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS Fixed Bracket
Siderise Bracket
Horizontal perimeter barrier installation: CW-FSH—03—A
Curtain Wall Fire Stop
Siderise CW-FS
Foil Tape Composite Panel
Siderise FT 120/45 Siderise NXS Fusion
Fixed Bracket Composite Panel
Siderise Bracket Siderise NXS Fusion
Curtain Wall Fire Stop
Siderise CW-FS
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Siderise Nexus Fusion ‘NXS’
Horizontal perimeter barrier installation: CW-FSH—04—A | 17VERSION 1.9 SEPTEMBER 2021
Curtain Wall Fire Stop Firestop Support Bracket
Siderise CW-FS Siderise Bracket
Foil Tape Fire Rated Board
Siderise FT 120/45 Siderise CW-FB Board
Firestop Support Bracket Steel Tray
Siderise Bracket min 0.9mm
75% Fire Rated Board
Siderise CW-FB Board
Curtain Wall Fire Stop
Siderise CW-FS
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Siderise CW-FB Spandrel protection
18 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS Fixed Bracket
Siderise Bracket
Horizontal perimeter barrier installation: CW-FSH—03—B
Curtain Wall Fire Stop
Siderise CW-FS
Foil Tape Composite Panel
Siderise FT 120/45 Class ‘A1’ Thermal Insulation
Fixed Bracket (min 80kg/m3)
Siderise Bracket
Composite Panel
Curtain Wall Fire Stop Class ‘A1’ Thermal Insulation
Siderise CW-FS
(min 80kg/m3)
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Class ‘A1’ (min 80kg/m3) Thermal Insulation
Horizontal perimeter barrier installation: CW-FSH—04—B | 19VERSION 1.9 SEPTEMBER 2021
Curtain Wall Fire Stop Firestop Support Bracket
Siderise CW-FS Siderise Bracket
Foil Tape 75% Fire Rated Board
Siderise FT 120/45 Siderise CW-FB Board
Fixed Bracket Steel Tray
SIDERISE Bracket min. 0.9mm
Curtain Wall Fire Stop Fire Rated Board
SIDERISE CW-FS SIDERISE CW-FB Board
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Siderise CW-FB Spandrel protection
20 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Horizontal perimeter barrier installation: CW-FSH—05—A
Acoustic Overlay Fixing Strap Fixed Bracket
Siderise CW-AB Generic Fixing Strap Siderise Bracket
Foil Tape Spandrel Panel
Siderise FT 120/45 Siderise NXR Core
Fixed Bracket Acoustic Overlay
Siderise Bracket Siderise CW-AB
Spandrel Panel
Fixing Strap
Generic Fixing Strap Siderise NXR Core
Curtain Wall Fire Stop
Siderise CW-FS
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Siderise Nexus lamella boards
Siderise acoustic barrier overlay AB
Horizontal perimeter barrier installation: CW-FSH—06—A | 21VERSION 1.9 SEPTEMBER 2021
Acoustic Overlay Fixing Strap Fixed Bracket
Siderise CW-AB Generic Fixing Strap Siderise Bracket
Foil Tape Spandrel Panel
Siderise FT 120/45 Siderise NXR Core
Fixed Bracket Acoustic Overlay
Siderise Bracket Siderise CW-AB
Spandrel Panel
Fixing Strap
Generic Fixing Strap Siderise NXR Core
Curtain Wall Fire Stop
Siderise CW-FS
Acoustic Upgrade
Siderise CVB
Products used
Siderise curtain wall fire stop CW-FS
Siderise support brackets
Siderise nexus lamella boards
Siderise acoustic barrier overlay AB
Siderise acoustic upgrade CVB/C
22 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Horizontal perimeter barrier installation: CW-FSH—07—A
Spandrel Panel
Siderise NXR Core
Curtain Wall Firestop Foil Tape
Siderise CW-FS Siderise RFT 120/45
Curtain Wall Fire Stop Spandrel Panel
Siderise CW-FS Siderise NXR Core
Fixed Bracket
Siderise Bracket
Products used
Siderise curtain wall fire stop CW-FS
| 23VERSION 1.9 SEPTEMBER 2021
Vertical perimeter barrier installation: CW-FSV—08—A Fixed Bracket
Siderise Bracket
Fixed Bracket
Siderise Bracket
Foil Tape Curtain Wall Fire Stop Spandrel Panel
Siderise FT 120/45 Siderise CW-FS Siderise NXR Core
Fixed Bracket Curtain Wall Firestop
Siderise Bracket Siderise CW-FS
Fixed Bracket Spandrel Panel
Siderise Bracket Siderise NXR Core
Curtain Wall Fire Stop
Siderise CW-FS
Foil Tape
Siderise FT 120/45
Products used
Siderise nexus lamella boards
Siderise curtain wall fire stop CW-FS
Siderise foil tape: RFT 120/45
24 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS Fixed Bracket
Siderise Bracket
Vertical perimeter barrier installation: CW-FS—08—B
Curtain Wall Firestop
Siderise CW-FS
Foil Tape Curtain Wall Fire Stop Spandrel Panel
Siderise FT 120/45 Siderise CW-FS Siderise NXR Core
Fixed Bracket Curtain Wall Fire Stop
Siderise Bracket Siderise CW-FS
Curtain Wall Fire Stop Spandrel Panel
Siderise CW-FS Siderise NXR Core
Curtain Wall Fire Stop
Siderise CW-FS
Foil Tape
Siderise FT 120/45
Products used
Siderise Nexus lamella boards
Siderise curtain wall fire stop CW-FS
Siderise foil tape: RFT 120/45
| 25VERSION 1.9 SEPTEMBER 2021
Vertical perimeter barrier installation: CW-FS—08—C Fixed Bracket
Siderise Bracket
Curtain Wall Fire Stop
Siderise CW-FS
Mullion Insert Curtain Wall Fire Stop Spandrel Panel
Siderise MI6 Siderise CW-FS Siderise NXR Core
Fixed Bracket Mullion Insert
Siderise Bracket Siderise MI6
Curtain Wall Fire Stop Curtain Wall Fire Stop
Siderise CW-FS Siderise CW-FS
Curtain Wall Fire Stop Spandrel Panel
Siderise CW-FS Siderise NXR Core
Foil Tape
Siderise FT 120/45
Products used
Siderise Nexus lamella boards
Siderise curtain wall fire stop CW-FS
Siderise foil tape: RFT 120/45
26 | SIDERISE®CW RANGE – PERIMETER BARRIERS AND FIRE STOPS
Regulations guidance Siderise CW-CB Cavity Barriers have For the purpose of Siderise product
been developed in recognition terminology, the ‘imperfection of fit’
• Approved Document B of the of the more demanding requirements is considered to be the discontinuity
Building Regulations requires that of the ‘Design Guide for the Fire between the edge of the structural
cavity barriers must have a minimum Protection of Buildings’ as issued by frame (slab or wall) and the interface
standard fire resistance of 30 The Loss Prevention Council. with the external cladding system.
minutes integrity and 15 minutes
insulation with regards to EN 1366-4 Cavity barriers … a definition “A Siderise CW-FS60 is suitable for
criteria respectively (EI 15). construction provided to close a installation in alignment with a 1 hour
concealed space against penetration rated compartment wall or floor to
• The Loss Prevention Council’s of smoke or flame, or provided to provide continuity of fire resistance
‘Design Guide for the Fire Protection restrict the movement of smoke or across the cavity (EI 60).
of Buildings’ states that cavity flame within such a space”.
barriers must have 30 minutes Siderise CW-FS120 is suitable for
integrity and minimum 30 minutes Siderise CW-CB30 is suitable for use installation in alignment with a 90
fire insulation (EI 30). as a cavity barrier (EI 30). minute or 2 hour rated compartment
wall or floor (EI 120).
• The ‘Standard Performance Criteria’ Siderise CW-FS Fire Stops are used
for fire and smoke stopping to maintain the continuity of the fire Siderise CW-FS180 is suitable for
issued by the Centre for Window resistance by sealing the gap between installation in alignment with a 3 hour
and Cladding Technology states: compartment floors (and walls) and compartment floor (EI 180).
“There shall be continuity of time the external curtain walling façade or
temperature rated fire and smoke any other external cladding systems.
stopping between the curtain wall
and compartment walls and floors. Fire stops … a definition “Sealing an
Any spaces or cavities between the imperfection of fit or design tolerance
two shall be effectively stopped between fire rated elements of a
against the spread of smoke and building to restrict the passage of fire
flame. The fire resistance of such and smoke for the same period of fire
stopping shall be equal to that resistance”.
required of the compartment floor
or wall against which it abuts”.
Technical specification
Siderise Perimeter Barriers & Fire stops for Curtain Walling
Form supplied Sheet : 1200mm x 1200mm x thickness (denoted by rating)
Pre-cut strips : 1200mm x (cavity + compression as per Certifire/Intertek) x thickness –
Colour please see tables 1 to 3
Finish Silver, with coloured identification tape centrally located on the product
Density Aluminium foil
Thermal conductivity Nominal 75 kg/m3
Cavities λ10 = 0.038 W/m.K (tested foil to foil)
Reaction to fire 20mm to 600mm - please see tables 1 to 3
Resistance to fire EN 13501-1 : Class ‘A1’
EN 13501-2 : EI 30 to EI 180 (minutes) - please see tables 1 to 3
| 27VERSION 1.9 SEPTEMBER 2021
FURTHER INFORMATION
Products available Ordering Technical & Sales support
The following Siderise products are When ordering please: Sales support
available. Sales Team
• Indicate contract title and location of T: +44 (0) 1656 730833
• Siderise CW perimeter barriers and project. E: [email protected]
fire stops for curtain walling – sheet
or pre-cut strip options • Specify product type required, e.g. Technical support
sheet form. Technical Services Team
• Siderise Aluminium Jointing Tape T: +44 (0) 1656 730833
must be used at all joints and • Specify fire rating or thickness E: [email protected]
intersections: RFT120/45 (120mm required.
wide x 45m rolls) Adhesive backed, Site Services support
Supplied in boxes of 8 • Specify void height or schedule of
sizes for each product type. Siderise offer a range of services
• Siderise Fire & Acoustic Sealant to contractors and installers. These
may be used for small gaps and • Confirm total linear metres required include toolbox product installation
undulations: FS120/310ML/WH (310ml for each size. and site installation inspection and
cartridge) Supplied in boxes of 25 reporting (subject to availability and
• Specify bracket type and quantity by agreement).
Additional information available required
Site Services Team
The following information is available • Specify foil tape quantity T: +44 (0) 1656 730833
for download via the website: requirement: RFT 120/45. E: [email protected]
• NBS Specification Clause • Order Siderise fire and acoustic gap System testing support
sealant 310ml cartridge
• Safety Data Sheet Siderise can provide assistance and
Environmental advice for large scale system testing to
• Cutting and Installation instructions BS EN, NFPA, ASTM and AS standards.
Siderise perimeter barriers and
• 3rd party approval - Certifire ‘CF 563’ fire stops for curtain walling are Testing Support Team
environmentally friendly. T: +44 (0) 1656 730833
• 3rd party approval - Intertek ‘WHI9- E: [email protected]
32944301’ • They contain no Volatile Organic
Compounds (VOCs) and no very Context
• 3rd party approval - Intertek ‘WH20- Volatile Organic Compounds
32944302’ (vVOCs). The information in this datasheet is
believed to be accurate at the date of
• Zero Ozone Depleting Potential publication. Siderise has a policy of
continuous product improvement and
• Zero Global Warming Potential reserves the right to alter or amend
the specifications of products without
• Recyclable prior notice. Siderise does not accept
responsibility for the consequences of
Specification support using the products described outside
of the recommendations within this
Siderise offer specifiers support from datasheet. Expert advice should be
initial enquiry and technical consultation sought where there is any doubt about
to project realisation. NBS draft the correct specification or installation
specifications are provided for standard of Siderise products.
products and applications and can
be tailored to suit specific project
performance requirements.
VERSION 1.72 APRIL 2021 | 28
Siderise Insulation Siderise Special Products
Passive fire solutions for the building Engineered acoustic solutions for equipment
envelope manufacture and construction
Siderise (Special Products) Ltd
United Kingdom Lady Lane Industrial Estate
Siderise Group, Forge Industrial Estate, T: +44 (0) 1473 827695
Maesteg, UK, CF34 0AY INDONESIA
T: +44 (0) 1656 730833 | F: +44 (0) 1656 812509 PT. Kencana Mirae Industri
Kawasan Ruko Business Park, Kebon Jeruk Blok I No.9
Middle East & India Jakarta Barat, DKI Jakarta 11620
T : (+62) 21 5890 8283 | E : [email protected]
Al Shafar Investment Building, www.kencanamirae.com
Al Quoz Industrial Area 1, Dubai, UAE
T: +971 (0) 4 580 4999 MEMBER
Asia Pacific
Siderise (Asia Pacific) Pte. Ltd. 80 Robinson Road,
#02-00 Singapore 068898
T: +65-963 19310
www.siderise.com