Table of Contents

1. Introduction...................................................................................................................... 3
2. Disaster Recovery Plan....................................................................................................... 4
3. Patch Management Plan................................................................................................... 11
4. Conclusion....................................................................................................................... 28
5. Reference........................................................................................................................ 29

Page 2 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1. Introduction

In this PBL we learn how to do disaster recovery plan and patch management plan step by step
procedure .

Page 3 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

2. Disaster Recovery Plan

The step-by-step plan consists of the precautions to minimize the effects of a disaster so the
organization can continue to operate or quickly resume mission-critical functions. Typically, disaster
recovery planning involves an analysis of business processes and continuity needs.

Screenshot For Step By Step Procedure
Disaster recovery plan

1.open server manager
2.choose add roles and features

1.click next

Page 4 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose role-based or feature-
based installation
2.click next

1.choose select server from the
server pool
2.click next

1.choose window server
essentials experience

Page 5 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click add features

1.click next

1.click next

Page 6 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click next

1.choose restart the destination
server automatically if required
2.click yes
3.click install

1.click close

Page 7 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.open server manager
2.open tools
3.open window server backup

1.click once local backup
1.click backup once

Page 8 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose different options
2.click next

1.choose full server
2.click next

1.choose local drives
2.click next

Page 9 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click next

1.click backup

1.finish

Page 10 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

3. Patch Management Plan

Patching not only keeps systems and applications running smoothly, it’s also one of the core
activities involved in keeping today’s organizations secure. Leaving machines unpatched makes
them vulnerable to cyber attacks.

Screenshot For Step By Step Procedure
Patch Management Plan

1.open server manager
2.open manage and choose add
roles and features

1.click next

Page 11 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose role based or feature
based installation
2.click next

1.choose select a server from
the server pool
2.click next

1.choose window server update
services & web server(IIS)
2.click next

Page 12 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click add features

1.click next

1.click next

Page 13 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose WID connectivity &
WSUS services

1.write E:\WSUS
2.click next

1.click next

Page 14 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click next

1.click install

1.open server manager
2.open tools
3.choose window server update
services

Page 15 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click next

1.Uncheck the Yes box
2.click next

1.Choose synchronize from
Microsoft update
2.click next

Page 16 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click next

1.click start connecting

1.click next

Page 17 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose English
2.click next

1.choose all options that
associates with window 10
2.click next

1.click next

Page 18 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose critical updates,
definition updates, security
updates & upgrades
2.click next

1.choose synchronize
automatically
2.write at first synchronizations
= 3:00 AM(choose a suitable
time when your internet
connection is faster)
3.synchronization per day
choose 1
4.click next

1.click next

Page 19 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.click finish

1.open server manager
2.choose group policy
management

Page 20 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.right click at file name computer
and create a new gpo

1.write Name: WSUS Client
2.click ok
1.right click at WSUS Client(that
made early) then choose edit

Page 21 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.expand folder name Window
Components

1.click at folder name Window
Update

1.Under the setting choose
Configure Automatic Updates

Page 22 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.choose Enabled
2.Configure automatic updating
: auto download and notify for
install
3.Scheduled install day: every
Friday
4.Scheduled install time: 5:00
5.click ok

1.Under setting click Enable
client-side targeting

1.choose enabled
2.Fill in your target group name
for this computer
3.click apply ,then ok

Page 23 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.open Update Services
2.right click at All Computer
then choose Add Computer
Group

1.Write your group computer
name
2.click add
1.choose enabled
2.write your group computer
name
3.click ok

Page 24 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.under setting click at Specify
intranet Microsoft update service
location

1.choose enabled
2.Set the intranet update service
for detecting updates:
http://nlb-wsus-01:8530
http://*your server name* :
*available port no.*
3.write the same at 3 of the
blank space provided here
4.click ok

1.open cmd and run as
administrator
2.write wuauclt.exe /detectnow
Press enter
3.write gpupdate /force
Press enter

Page 25 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.write gpresult /r
Press enter
2.close cmd after the program
finish run

1.open update services
2.click at All Updates
1.right click at the top 1 of the
list
2.click approve

Page 26 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

1.right click at *your computer
group name*
2.choose Approved for Install

1.click ok

1.open Windows Update
2.click check for updates button

Page 27 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

4. Conclusion
Many disasters can quickly knock out your entire corporate network or database. If you don’t have
a disaster recovery plan in place, chances are that the consequences will be severe. A disaster
recovery plan describes scenarios for resuming work quickly and it is an important part of the
business continuity plan and it allows for sufficient IT recovery and the prevention of data loss.
For most organizations, implementing patch management tools and processes to ensure that their
IT operations continue to run smoothly in the face of an Internet full of new and changing threats.

Page 28 of 29

Operating Systems Administration 1- CIT 0553

INDUSTRIAL ELECTRONICS DEPARTMENT

5. Reference
1. Pass Institute, September 30 2015, Windows Server Backup - Disaster Recovery,
https://www.youtube.com/watch?v=9NrSl1jOSF0&t=512s
2. NLB Solutions, May 11 2017, 12.1 Installing and configuring Windows Server 2016 Update
Services (Step by Step guide), https://www.youtube.com/watch?v=2olvZOgn0LQ

Page 29 of 29


Click to View FlipBook Version