The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by McCrometer, 2020-11-05 11:15:04

Ag Resource Binder (English)

Agricultural





Product Suite















Overview and Specifications



Section 1







McPropeller Meters



Mc Propeller






Flow Meters






Ideal Flow Measurement for

Agriculture and Irrigation














































The Best Solution For Irrigation Flow Measurement

Magnetic Coupling System
Register Options Heavy Gauge Stainless Isolates register and drive
Steel Support system from flow and allows
Mechanical Register - Standard Resists corrosion unrestricted impeller movement
An instantaneous flowrate
indicator with optional six-digit Long-lasting Stainless
or seven-digit straight reading Steel Ball Bearings
totalizer and standard. The Factory lubricated and
register is hermetically sealed protected from flow
with a die cast aluminum case. stream
This protective housing includes
a domed acrylic lens and hinged Straightening Vanes
lens cover with locking clasp. For optimum flow
profiles
Digital Register - Optional
The FlowCom digital register
has an expected battery life Corrosion-Resistant
of 6-10 years and is housed Impeller
in a NEMA 4X rated, durable Made of durable
enclosure. FlowCom’s indicator polymer material,
and totalizer has a non- factory calibrated to
volatile memory. The five-digit retain accuracy
indicator shows flow rate in 22
different units, including GPM,
CFS or MGD. The eight-digit Wide Variety of End
totalizer provides volumetric Flexible Cable Drive Fittings
flow data and is available in Simple and durable, Epoxy-Coated Carbon Including threaded,
20 different units including protected by self- Steel Body grooved-end, flanged,
Gallons, AF or CF. Units of lubricating cable guide All stainless steel and weld-on
measure are user-selectable. construction available
Available with optional 4-20mA
and/or pulse output.
Wireless Register - Optional Simple and Effective
FlowConnect with Exact Read
advanced technology ensures • Available with all of the features you need, none of
you have an accurate and exact the features you don’t
reading from register to website.
Unlike traditional telemetry • Requires no power to operate, no batteries to fail
systems, FlowConnect’s unique
one-piece design eliminates • Straightforward, hassle-free installation; just cut the
the need for cables, pole pipe and bolt on
mounting and other hardware.
Get more data, faster and have • Easy to read with a mechanical register that calculates
it delivered to the palm of both total and instantaneous flow
your hand with FlowConnect.
Available with cellular or satellite
communication protocols.




When it comes to your flow measurement needs, there are many options available. But for
a highly accurate and reliable product at a reasonable price, McCrometer makes the most
sense.

The Mc Propeller is the industry standard for propeller technology, continually
outperforming all other flow meters in the agricultural and turf markets.

Our flow meters are simple to install and operate, require minimal maintenance, and are
equipped with all the features you need. It’s no wonder that it’s the #1 choice for irrigation use.

Pressure Standard Indicator/ Digital Wireless
Rating Totalizer Totalizer
M0300 - Bolt-on Saddle
• Stainless steel construction
4“ - 16” 150 PSI Standard Standard Optional Optional
• Can be used on a variety of pipe materials: Steel, plastic, cast
iron, cement, or asbestos cement
M0300SW - Bolt-on Saddle Surface Water
• Stainless steel construction
4” - 12” 150 PSI Standard Standard Optional Optional
• Can be used on a variety of pipe materials: Steel, plastic, cast
iron, cement, or asbestos cement
M1400 - Large Line, Bolt-on Saddle
18” - 48” • Can be used on a variety of pipe materials: Steel, plastic, cast 75 PSI Standard Standard Optional Optional
iron, cement, or asbestos cement
M1700 - Open Flow
10” - 24” • Can be used on a variety of pipe materials: Steel, plastic, cast Atmospheric Standard Standard Optional Optional
iron, cement, or asbestos cement
M1700 - Open Flow
24” - 72” • Can be used on a variety of pipe materials: Steel, plastic, cast Atmospheric N/A N/A Standard Optional
iron, cement, or asbestos cement
MF100 - Flanged End
2” - 12” • AWWA Class D Flanges 150 PSI Standard Standard Optional Optional
• Optional flow straightening vanes welded in the tube
ML100 - Irrigation Flanged
6” - 12” 75 PSI Standard Standard Optional Optional
• Optional flow straightening vanes welded in the tube



M0300 M0300SW M1400 MF100 ML100 M1700









Options and Accessories TYPICAL APPLICATIONS


• Electronic outputs connect with • Agricultural Irrigation • Park Management
your system for better irrigation
management • Turf Irrigation • Pumping Stations
• Over-run bearing extends meter • Center Pivot Systems • Canal Laterals
life in high flow applications • Drip and Sprinkler Systems • Golf Courses
• 7-digit totalizer increases the • Greenhouse Growers

maximum total recordable volume




Designed for Accuracy, Built to Last

• Durable, built with a time-tested rugged
To find out more about our flow measurement
design CALL TO ACTION STUFF HERE
• Consistent and repeatable products, or for a free flow evaluation, contact
measurements due to the simplicity of your nearest Mc Propeller representative today
our proven propeller design or visit our website at www.mccrometer.com.
• Versatile, with a wide range of You can reach us directly at 1-800-220-2279.
applications

Specifications

All flow meters comply with the American Water Works Association Standard No. C704-08.
Performance
Accuracy/Repeatability ±2% of reading guaranteed throughout full range; ±1% over reduced range; calibrated
in our NIST traceable test facilities. Repeatability of 0.25% or better.

Maximum Temperature (Standard Construction) 160°F constant.

materials
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel.
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are standard.
The register is hermetically sealed within a die-cast aluminum case. This protective
housing includes a domed acrylic lens and a hinged lens cover with locking hasp.
Propeller Propellers are manufactured of high-impact plastic, retaining their shape and accuracy
over the life of the meter. High temperature impeller is optional.

Any published technical data and specifications are subject to change without notice.

The Flow Straightener


A tight-spot solution that saves money

By reshaping irregular flow into a smooth stream, the advanced Flow Straightener offers higher accuracy and repeatability when installed
in as little as 1.5 pipe diameters from chemigation, butterfly and gate valves, out-of-plane elbows, and reducers. Saving money by
reducing piping and labor costs, the Flow Straightener is ideal for both new and retrofit installations.




Straight Pipe Requirements Other flow meters


Mc Propeller M0308 Pipe Diameters
with flow straightener
Meter Upstream Downstream
Flow Direction M0308 with flow 1.5 1

straightener
Other flow meters 10 5

Committed to Quality
Manufacturing in the USA
McCrometer prides itself on the fact that all of its flow meters are
designed, manufactured, and tested in the USA. Manufacturing
takes place in our headquarters in Hemet, California and we own
and operate one of the world’s largest volumetric test facilities in
Porterville, California. Our manufacturing facilities and quality control
systems are the foundation for being a trusted supplier. Our USA
based, high quality manufacturing is another reason our customers
around the world have confidently chosen McCrometer flow meters
for their most challenging flow applications since 1955.




Corporate Headquarters:
3255 West Stetson Avenue, Hemet, CA 92545 USA
© 2018 McCrometer, Inc / Printed in U.S.A. Tel: 951-652-6811 | Fax 951-652-3078
Lit# 24519-14, Rev. 1.3 | 11-27-18 www.mccrometer.com

Specification Sheet
M0300 Strap-on Saddle Flow Meter



DESCRIPTION

All Mc Propeller flow meters are manufactured
to comply with applicable provisions of AWWA
Standard No. C704-02 for propeller-type flow
meters.

FEATURES

Saddle

• The fabricated stainless steel saddle
eliminates the fatigue-related breakage
common to cast iron and aluminum saddles
and provides unsurpassed corrosion
protection.

• Fabricated stainless steel construction offers
the additional advantage of being flexible
enough to conform to out-of-true pipe.
Impellers
• Impellers are manufactured of high-impact
plastic, capable of retaining their shape and Typical Applications
accuracy over the life of the meter.

• Each impeller is individually calibrated at • Center pivot systems
the factory to accommodate the use of any • Sprinkler irrigation systems
standard McCrometer register, and since no • Drip irrigation systems
change gears are used, the M0300 can be
field-serviced without the need for factory • Golf course and park water management
recalibration. • Gravity turnouts from underground pipelines
Bearings • Commercial nurseries
• Factory lubricated, stainless steel bearings • Water and wastewater management
are used to support the impeller shaft.
• The shielded bearing design limits the entry
of materials and fluids into the bearing
chamber providing maximum bearing
protection. • The register housing protects both the register
and cable drive system from moisture while
Register
allowing clear reading of the flowrate indicator
• The instantaneous flowrate indicator is and totalizer.
standard and available in gallons per minute,
cubic feet per second, liters per second and
other units.
• The register is driven by a flexible steel cable
with a magnetically coupled drive, encased
within a protective vinyl liner.








24517-00 Rev. 2.2 | 8JUL2019

Specification Sheet
M0300 Strap-on Saddle Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory. A straight run of full pipe the length of ten pipe diameters upstream and one diameter downstream
of the meter is recommended for meters without straightening vanes. Meters with optional straightening vanes
require at least five pipe diameters upstream and two diameters downstream of the meter. For more information,
see the section “Pipe Run Requirements”.


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Maximum Temperature (Standard Construction) 160°F constant

Pressure Rating 150 psi. Consult factory for higher rated version.
Materials
Saddle 304 stainless steel construction

Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel
Magnets (Permanent type) Alnico
Bearing Housing For models 4” to 16”: 304 stainless steel standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.
Options

• Extended warranty
• Register extensions
• High temperature construction, 180°F max
• Marathon bearing assembly for higher than normal flowrates 4” and larger

• Digital register available in all sizes of this model
• A complete line of flow recording / control instrumentation
• Canopy boot
• Saddle can be constructed to fit any outside diameter pipe dimensions, including
metric sizes.
• Blank repair saddle
• Can be used on a variety of pipe materials such as steel, plastic, cast iron, cement or
asbestos cement
• Straightening vanes





Page 2 24517-00 Rev. 2.2 | 8JUL2019

Specification Sheet
M0300 Strap-on Saddle Flow Meter


DIMENSIONS















FLOW

M0300 DIMENSIONS
Meter and Nominal Pipe Size 4 6 8 10 12 14 16
Maximum Flow U.S. GPM 600 1200 1500 1800 2500 3000 4000
Minimum Flow U.S. GPM 50 90 100 125 150 250 275
Approx. Head Loss in Inches at Max. 23.00 17.00 6.75 3.75 2.75 2.00 1.75
Flow
Approx. Shipping Weight-lbs. 12 17 21 24 28 28 30
A (inches) 7 5/8 15 15 15 15 15 15
B (inches) 8 1/4 10 3/4 10 3/4 10 3/4 11 3/4 13 3/4 13 3/4
C (inches) 7 8 8 9 1/2 9 1/2 9 1/2 9 1/2
D (inches) 4* 5 1/8* 6* 7* 7 1/4 7 1/4 7 1/4
E (inches) 10 3/4 14 15 17 19 20 5/8 21 5/8



For larger sizes see Model M1400.
McCrometer reserves the right to change design or specification without notice.
*Standard pipe only. For other than standard pipe, consult factory for cutout dimensions.
Please specify the inside diameter of the pipe when ordering.

































Page 3 24517-00 Rev. 2.2 | 8JUL2019

INSTALLATION
Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory. A straight run of full pipe the length of ten pipe diameters upstream and one diameter downstream
Specification Sheet
of the meter is recommended for meters without straightening vanes. Meters with optional straightening vanes
M0300 Strap-on Saddle Flow Meter

require at least five pipe diameters upstream and one diameter downstream of the meter.
PIPE RUN REQUIREMENTS

Upstream Requirement


Mc Propeller meters should be installed Flow B

a minimum of five to ten diameters
downstream of any obstructions.
15”
Downstream Requirement
A
The downstream run should be one
diameter of straight pipe length after Measure 15” from center of
the meter. ell to determine average
location of the propeller tip.

Confi guration A B
Without straightening vanes 10 1
Elbow shown - Other piping components can be
With straightening vanes 5 1 pumps, valves and expansions or reductions
With FS100 Flow Straightener 1.5 1




STRAIGHTENING VANES

Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal

sand separator. These cause swirling flow in the line that affect propeller meters. Well developed swirls can

travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.


















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener

















Page 4 24517-00 Rev. 2.2 | 8JUL2019

Specification Sheet
M0300 Strap-on Saddle Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register







Mechanical Totalizer

The instantaneous flowrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a flexible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the flowrate indicator and totalizer.








Digital Totalizer



The optional FlowCom register displays a flowmeter’s flowrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard

4-20mA signal. The FlowCom can be fitted to any new or existing McCrometer

propeller flowmeter.






Wireless Telemetry

The optional FlowConnect is designed specifically for wireless telemetry via either

satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility
provides data tools that can analyze flow rate, consumption, and possible

anomalies in an irrigation system.





Page 5 24517-00 Rev. 2.2 | 8JUL2019

Specification Sheet
M0300 Strap-on Saddle Flow Meter


Accuracy ACCURACY CHART
105%

102%
100%
98%


95%


90%




0 1 2 3 4 5 6 7 8 9 10
12”
8”, 10” VELOCITY (FEET PER SECOND)
6”
4”
3”

Standard flowrates for McCrometer propeller meters are shown below. Readings are guaranteed accurate
within ±2% in these flowrates. Please note that over 80 percent of the meter’s flow range, the accuracy is better


than ±1%.
Nominal Meter Size 2” 2.5” 3” 4” 6” 8” 10” 12” 14” 16” 18” 20” 24”
Minimum Flow(U.S.GPM) 40 40 40 50 90 100 125 150 250 275 400 475 700
Maximum Flow(U.S.GPM) 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500
Dial Face Range 250 250 250 800 1300 2500 3000 4000 6000 8000 10000 10000 15000
Headloss


Headloss refers to the fluid pressure lost due to the meter. Propeller meters have very low permanent headloss
as seen in the chart below. HEADLOSS CHART
1.263 35
1.083 30

0.902 25

HEADLOSS 0.722 20 HEADLOSS
3” 4”
(PSI) 0.541 15 (INCHES
6”
0.361 10 OF WATER)

0.180 8” 10” 5
12”
0.000 0
0 1 2 3 4 5 6 7 8 9 10
VELOCITY (FEET PER SECOND)

Nominal Meter Size 3” 4” 6” 8” 10” 12” 14” 16” 18” 20” 24”
Max. Headloss (in. H 2 0 column) 30 23 17 7 4 3 2 2 2 1 1
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 6 24517-00 Rev. 2.2 | 8JUL2019

Specification Sheet
M0300SW Reverse Strap-on Saddle Flow Meter



DESCRIPTION

The M0300SW is a strap-on reverse-helix*
propeller meter designed to shed debris often
associated with surface water applications.
This flow meter is designed with the meter body
turned 180 degrees from normal, a propeller
installed nose-first on the bearing shaft, and
a reverse flow style bearing assembly. This
configuration allows the ell to curve with the
flow, allowing grass or other debris to shed off
with ease. The assembly design also reduces
the ability of sand and silt to accumulate in the
bearing.

All Mc Propeller flow meters are manufactured
to comply with applicable provisions of AWWA
Standard No. C704-02 for propeller-type flow
meters.


FEATURES
Typical Applications
Saddle
• The fabricated stainless steel saddle
eliminates the fatigue-related breakage • Center pivot systems
common to cast iron and aluminum saddles • Sprinkler irrigation systems
and provides unsurpassed corrosion • Drip irrigation systems
protection. • Golf course and park water management
• Fabricated stainless steel construction offers • Gravity turnouts from underground
the additional advantage of being flexible pipelines
enough to conform to out-of-true pipe. • Commercial nurseries
Impellers • Water and wastewater management

• The impellers are manufactured of high-
impact plastic, capable of retaining their
shape and accuracy over the life of the meter.
Register
• Each impeller is individually calibrated at
the factory to accommodate the use of any • The instantaneous flowrate indicator is standard
standard McCrometer register, and since no and available in gallons per minute, cubic feet per
change gears are used, the M0300SW can be second, liters per second and other units.
field-serviced without the need for factory • The register is driven by a flexible steel cable with
recalibration. a magnetically coupled drive, encased within a
Bearings protective vinyl liner.
• Factory lubricated, stainless steel bearings • The register housing protects both the register
are used to support the impeller shaft. and cable drive system from moisture while
allowing clear reading of the flowrate indicator
• The shielded bearing design limits the entry of and totalizer.*
materials and fluids into the bearing chamber
providing maximum bearing protection. • 4” meters use a forward helix propeller with a reverse
register.



24517-04 Rev. 1.6 | 4NOV2019
www.mccrometer.com

Specification Sheet
M0300SW Reverse Strap-on Saddle Flow Meter


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Maximum
Temperature (Standard Construction) 160°F constant
Pressure Rating 150 psi. Consult factory for higher rated version.
Materials

Saddle 304 stainless steel construction
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel
Magnets (Permanent type) Alnico
Bearing Housing For models 4” to 16”: 304 stainless steel standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.
Options

• Extended warranty
• Register extensions
• High temperature construction, 180°F max

• Marathon bearing assembly for higher than normal flowrates 4” and larger
• Digital register available in all sizes of this model
• A complete line of flow recording / control instrumentation
• Canopy boot
• Saddle can be constructed to fit any outside diameter pipe dimensions,
including metric sizes.
• Blank repair saddle
• Can be used on a variety of pipe materials such as steel, plastic, cast iron,
cement or asbestos cement



















Page 2 24517-04 Rev. 1.6 | 4NOV2019
www.mccrometer.com

Specification Sheet
M0300SW Reverse Strap-on Saddle Flow Meter


DIMENSIONS


A


D D
B
E




C FLOW Meter Tube Installation Cut-Out Detail
DIMENSIONS ARE IN INCHES NAME DATE
DIMENSIONS ARE IN INCHES
M0300SW DIMENSIONS
Meter and Nominal Pipe Size 4 6 8 10 12 14 16
Minimum Flow U.S. GPM 50 90 100 125 150 250 275
Maximum Flow U.S. GPM 600 1200 1500 1800 2500 3000 4000
Max. Flow w/Marathon Bearing 900 1800 2250 2700 3750 4500 6000
Approx. Head Loss in Inches at 23 17 6.75 3.75 2.75 2.00 1.75
Max. Flow
Standard Dial Face (GPM/Gal) * 1000/100 1800/100 2500/100 3K/1000 4K/1000 6K/1000 8K/1000
OD up to (inches) 5.5 7.5 9.5 11.5 13.5 15.5 17.5
A (inches) 7 5/8 15 15 15 15 15 15
B (inches) 8 1/4 10 3/4 10 3/4 10 3/4 11 3/4 13 3/4 13 3/4
C (inches) 7 8 8 9 1/2 9 1/2 9 1/2 9 1/2
D (inches) 4** 5 1/8** 6** 7** 7 1/4 7 1/4 7 1/4
E (inches) 10 3/4 14 15 17 19 20 5/8 21 5/8
Approx. Shipping Weight-lbs. 12 17 21 24 28 28 30
*Indicates the dial face range and multiplier
**Standard pipe only. For other than standard pipe, consult factory for cutout dimensions.



For larger sizes see Model M1400.
Please specify the inside diameter of the pipe when ordering.
McCrometer reserves the right to change design or specification without notice.
























Page 3 24517-04 Rev. 1.6 | 4NOV2019
www.mccrometer.com

Specification Sheet
M0300SW Reverse Strap-on Saddle Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS


Confi guration A B

Without
straightening vanes 8 3
With Flow
straightening vanes 3 3
A


15”



B

Measure 15” from center of
ell to determine average
location of the propeller tip.



Elbow shown - Other piping components can be
pumps, valves and expansions or reductions




STRAIGHTENING VANES


Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal

sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can

travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in and bolt-in.


















Elbows out of plane Bolt-in straightening vanes



Page 4 24517-04 Rev. 1.6 | 4NOV2019
www.mccrometer.com

Specification Sheet
M0300SW Reverse Strap-on Saddle Flow Meter

TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000
500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer

The instantaneous owrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer

propeller owmeter.







Wireless Telemetry
The optional FlowConnect is designed speci cally for wireless telemetry via either

satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).

You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility
provides data tools that can analyze ow rate, consumption, and possible

anomalies in an irrigation system.

Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-04 Rev. 1.6 | 4NOV2019
www.mccrometer.com



Specification Sheet
M1400 Strap-on Saddle Large Line Flow Meter



DESCRIPTION

All Mc Propeller flow meters are manufactured
to comply with the applicable provisions
of AWWA standard No. C704-02 and latest
revisions for propeller type flow meters.

FEATURES

Saddle

• The fabricated, epoxy-coated steel saddle
eliminates the fatigue-related breakage
common to cast iron and aluminum saddles
and provides unsurpassed corrosion
protection.

• Fabricated steel construction offers the
additional advantage of being flexible
enough to conform to out-of-true pipe.
Impellers
• Impellers are manufactured of high-impact Typical Applications
plastic, capable of retaining their shape and
accuracy over the life of the meter. The McCrometer propeller meter is the most

• Each impeller is individually calibrated at widely used flowmeter for agricultural and turf
the factory to accommodate the use of any irrigation measurement. Typical applications
standard McCrometer register, and since include:
no change gears are necessary, the M1400 • Golf course and park water management
can be field-serviced without the need for • Gravity turnouts for underground pipelines
factory recalibration.
• Pump stations
Bearings • Water and wastewater management
• Factory lubricated, stainless steel bearings • Sprinkler irrigation systems
are used to support the impeller shaft.
• Drip irrigation systems
• The sealed bearing design limits the entry
of materials and fluids into the bearing
chamber providing maximum bearing
protection. • The register is driven by a flexible steel cable
encased within a protective vinyl liner.
Register
• The register housing protects both the register
• An instantaneous flowrate indicator is
standard and available in gallons per minute, and cable drive system from moisture while
allowing clear reading of the flowrate indicator
cubic feet per second, liters per second and and totalizer.
other units.













24517-15 Rev. 2.2 | 8JUL2019

Specification Sheet
M1400 Strap-on Saddle Large Line Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise the
factory. A straight run of full pipe the length of ten pipe diameters upstream and two diameters downstream of
the meter is recommended for meters without straightening vanes. Meters with optional straightening vanes
require at least five pipe diameters upstream and two diameters downstream of the meter.

SPECIFICATIONS


Performance
• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Maximum Temperature (Standard Construction) 160°F constant
Pressure Rating 75 psi
Materials

Bearing Assembly • Impeller shaft is 316 stainless steel
• Ball bearings are 440C stainless steel
Magnets (Permanent type) Alnico
Bearing Housing Brass standard, 316 stainless steel optional

Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.

Options
• Extended warranty
• Saddle can be constructed to fit any outside diameter pipe dimensions, including
metric sizes
• Can be used on a variety of pipe materials such as steel, plastic, cast iron, cement or
asbestos cement
• Register extensions
• Marathon bearing assembly for higher than normal flowrates

• Digital register available in all sizes of this model
• A complete line of flow recording / control instrumentation
• Blank repair saddle
• Canopy boot










Page 2 24517-15 Rev. 2.2 | 8JUL2019

Specification Sheet
M1400 Strap-on Saddle Large Line Flow Meter


DIMENSIONS



MEASURE “L” ALONG
LENGTH OF PIPE






FLOW

MEASURE “W”
OVER CURVE OF PIPE
PIPELINE CUTOUT




M1400 DIMENSIONS
Meter and Nominal
Pipe Size (inches) 18 20 22 24 26 28 30 32 34 36 42 48
Maximum Flow U.S.
GPM 5000 6000 7000 8500 8500 12500 12500 12500 17000 17000 25000 30000
Minimum Flow U.S.
GPM 400 475 650 700 700 1200 1200 1200 1500 1500 2000 2500
Standard Dial Face 10000/ 10000/ 10000/ 15000/ 15000/ 15000/ 15000/ 15000/ 30000/ 30000/ 35000/ Consult
(GPM/Gal) 1000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 Factory
Approx. Head Loss in
Inches at Max. Flow 1.5 1.25 1.0 1.0 .75 .60 .52 .50 .45 .40 .40 .40
Approx. Shipping 55 65 73 80 100 100 110 110 130 140 200 200
Weight, lbs.
A (inches) 17 17 17 17 17 17 17 17 17 17 17 17
B (inches) 14 3/8 16 3/8 16 3/8 18 3/8 20 3/8 20 3/8 20 3/8 22 3/8 23 3/8 24 3/8 30 3/8 36 3/8
C (inches) 12 12 12 12 12 18 18 18 18 18 18 18
L (inches) 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 12 12 12 12
W (inches) 13.5 13.5 13.5 13.5 13.5 13.5 13.5 13.5 16 16 16 16




























Page 3 24517-15 Rev. 2.2 | 8JUL2019

INSTALLATION
Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory. A straight run of full pipe the length of ten pipe diameters upstream and one diameter downstream
Specification Sheet
of the meter is recommended for meters without straightening vanes. Meters with optional straightening vanes
M1400 Strap-on Saddle Large Line Flow Meter

require at least five pipe diameters upstream and one diameter downstream of the meter.
PIPE RUN REQUIREMENTS

Upstream Requirement

Mc Propeller meters should be installed Flow B

a minimum of five to ten diameters
downstream of any obstructions.
15”
Downstream Requirement
A
The downstream run should be one
diameter of straight pipe length after Measure 15” from center of
the meter. ell to determine average
location of the propeller tip.

Confi guration A B
Without straightening vanes 10 1
Elbow shown - Other piping components can be
With straightening vanes 5 1 pumps, valves and expansions or reductions
With FS100 Flow Straightener 1.5 1



STRAIGHTENING VANES


Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal

sand separator. These cause swirling flow in the line that affect propeller meters. Well developed swirls can

travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.


















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener

















Page 4 24517-15 Rev. 2.2 | 8JUL2019

Specification Sheet
M1400 Strap-on Saddle Large Line Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register







Mechanical Totalizer

The instantaneous flowrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a flexible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the flowrate indicator and totalizer.








Digital Totalizer



The optional FlowCom register displays a flowmeter’s flowrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard

4-20mA signal. The FlowCom can be fitted to any new or existing McCrometer

propeller flowmeter.






Wireless Telemetry

The optional FlowConnect is designed specifically for wireless telemetry via either

satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility
provides data tools that can analyze flow rate, consumption, and possible

anomalies in an irrigation system.





Page 5 24517-15 Rev. 2.2 | 8JUL2019

Specification Sheet
M1400 Strap-on Saddle Large Line Flow Meter


Accuracy ACCURACY CHART
105%

102%
100%
98%


95%


90%




0 1 2 3 4 5 6 7 8 9 10
12”
8”, 10” VELOCITY (FEET PER SECOND)
6”
4”
3”
Standard flowrates for McCrometer propeller meters are shown below. Readings are guaranteed accurate



within ±2% in these flowrates. Please note that over 80 percent of the meter’s flow range, the accuracy is better
than ±1%.
Nominal Meter Size 2” 2.5” 3” 4” 6” 8” 10” 12” 14” 16” 18” 20” 24”
Minimum Flow(U.S.GPM) 40 40 40 50 90 100 125 150 250 275 400 475 700
Maximum Flow(U.S.GPM) 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500
Dial Face Range 250 250 250 800 1300 2500 3000 4000 6000 8000 10000 10000 15000
Headloss


Headloss refers to the fluid pressure lost due to the meter. Propeller meters have very low permanent headloss
as seen in the chart below. HEADLOSS CHART
1.263 35
1.083 30

0.902 25

HEADLOSS 0.722 20 HEADLOSS
3” 4”
(PSI) 0.541 15 (INCHES
6”
0.361 10 OF WATER)

0.180 8” 10” 5
12”
0.000 0
0 1 2 3 4 5 6 7 8 9 10
VELOCITY (FEET PER SECOND)

Nominal Meter Size 3” 4” 6” 8” 10” 12” 14” 16” 18” 20” 24”
Max. Headloss (in. H 2 0 column) 30 23 17 7 4 3 2 2 2 1 1
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 6 24517-15 Rev. 2.2 | 8JUL2019

Specification Sheet
MF100 Fixed Ell Flanged Flow Meter



DESCRIPTION

The Model MF100 is designed to provide high
pressure rating and excellent meter accuracy
in an inexpensive package.
The model MF100 is designed for a maximum
continuous working pressure of up to 150 psi
and is fitted with AWWA Class D flanges.
All Mc Propeller flow meters are manufactured
to comply with the applicable provisions of
AWWA standard No. C704-02.

The impeller and drive assembly are easily
accessed through the open end of the meter
tube.

FEATURES

Impellers

• Impellers are manufactured of high-impact
plastic, capable of retaining their shape and
accuracy over the life of the meter.
• Each impeller is individually calibrated at Typical Applications
the factory to accommodate the use of any
standard McCrometer register, and since • Center pivot systems
no change gears are necessary, the MF100 • Sprinkler irrigation systems
can be field-serviced without the need for • Drip irrigation systems
factory recalibration. • Golf course and park water management

Bearings • Commercial nurseries
• Factory lubricated stainless steel bearings • Water and wastewater management
are used to support the impeller shaft.

• The sealed bearing design limits the entry
of materials and fluids into the bearing
chamber providing maximum bearing
protection.

Register • The register is driven by a flexible steel cable
encased within a protective vinyl liner.
• An instantaneous flowrate indicator is
standard and available in gallons per minute, • The register housing protects both the register
cubic feet per second, liters per second and and cable drive system from moisture while
allowing clear reading of the flowrate indicator
other units.
and totalizer.














24517-10 Rev. 2.1 | 23MAR2020

Specification Sheet
MF100 Fixed Ell Flanged Flow Meter


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 2” to 12”
Maximum
Temperature (Standard Construction) 160°F constant
Pressure Rating 150 psi. Consult factory for higher rated version.
Materials

Spool Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Body Epoxy-coated carbon steel pipe conforming to A.S.A pipe schedules
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel
Magnets (Permanent type) Alnico

Bearing Housing • For models 2” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.
Options

• Extended warranty
• Register extensions

• All stainless steel construction
• High temperature construction
• Marathon bearing assembly for higher than normal flowrates
• A complete line of flow recording/control instrumentation
• Flow straightening vanes
• Certified calibration test results

• Canopy boot
















Page 2 24517-10 Rev. 2.1 | 23MAR2020

Specification Sheet
MF100 Fixed Ell Flanged Flow Meter


DIMENSIONS

FLOW

















MF100 DIMENSIONS
inches 2 2 1/2 3 4 6 8 10 12
Meter Size
mm 51 64 76 102 152 203 254 305
GPM 40 40 40 50 90 100 125 150
Minimum Flow
LPS 2.5 2.5 2.5 3.2 5.7 6.3 7.9 9.5
GPM 250 250 250 600 1200 1500 1800 2500
Maximum Flow
LPS 15.8 15.8 15.8 37.9 75.7 94.6 113.6 157.7
Maximum Flow w/ GPM 900 1800 2250 2700 3750
Marathon Bearing
Approx. Head Loss inches 29.5 29.5 29.5 23 17 6.75 3.75 2.75
in Inches at Max. mm 749 749 749 584 432 171 95 70
Flow
Standard Dial GPM/ 250/ 250/ 250/ 800/ 1300/ 2500/ 3000/ 4000/
Face* Gal 10 10 10 100 100 100 1000 1000
Approx. Shipping lbs 40 40 40 50 60 102 157 176
Weight, lbs. kg 18 18 18 23 27 46 71 80
inches 0.75 0.75 0.75 0.75 0.375 0.375 1 1
B
mm 19 19 19 19 10 10 25 25
inches 4.75 5.5 6 7.5 9.5 11.75 14.25 17
C
mm 121 140 152 191 241 298 362 432
inches 6 7 7.5 9 11 13.5 16 19
D
mm 152 178 191 229 279 343 406 483
inches 12.16 12.66 13 13.66 16 17.3 22.5 24
H
mm 309 322 330 347 406 439 572 610
inches 13 13 13 20 20 20 20 20
L
mm 330 330 330 508 508 508 508 508
No. of Bolts Per Flange 4 4 4 8 8 8 12 12
*Indicates the dial face range and multiplier



















Page 3 24517-10 Rev. 2.1 | 23MAR2020

Specification Sheet
MF100 Fixed Ell Flanged Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1

Flow 15”




A Measure 15” from center of
ell to determine average
location of the propeller tip.


Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions




STRAIGHTENING VANES

Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal
sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can


travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.



















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-10 Rev. 2.1 | 23MAR2020

Specification Sheet
MF100 Fixed Ell Flanged Flow Meter


TOTALIZERS

Typical face plates

2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000
500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register




Mechanical Totalizer


The instantaneous owrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.





Wireless Telemetry


The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.


Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-10 Rev. 2.1 | 23MAR2020



Specification Sheet
MG100 and MS100 Fixed Ell Main Line Flowmeter



DESCRIPTION

Model MG100 and MS100 meters are designed
to provide high pressure rating and “main line”
meter accuracy in an inexpensive package.
The flow meters are manufactured to comply
with the applicable provisions of the AWWA
Standard No. C704-02 for propeller type flow
meters.

The impeller and drive assembly are fully
accessible through the open end of the meter
tube.

FEATURES

Impellers

• Impellers are manufactured of high-impact
plastic, capable of retaining their shape and
accuracy over the life of the meter.
• Each impeller is individually calibrated at Typical Applications
the factory to accommodate the use of any
standard McCrometer register, and since The McCrometer propeller meter is the most
no change gears are used, the flow meters widely used flowmeter for municipal and
can be field-serviced without the need for wastewater treatment applications as well as
factory recalibration. agricultural and turf irrigation measurement.
Typical applications include:
Bearings
• Center pivot systems
• Factory lubricated stainless steel bearings • Sprinkler irrigation systems
are used to support the impeller shaft. • Drip irrigation systems
• The shielded bearing design limits the entry • Golf course and park water management
of materials and fluids into the bearing • Gravity turnouts from underground pipelines
chamber providing maximum bearing • Commercial Nurseries
protection. • Water and Wastewater management
Register
• An instantaneous flowrate indicator is
standard and available in gallons per minute,
cubic feet per second, liters per second and • The register housing protects both the register
other units. and cable drive system from moisture while
• The register is driven by a flexible steel cable allowing clear reading of the flowrate indicator
encased within a protective vinyl liner. and totalizer.















24517-17 Rev. 2.3 | 23MAR2020

Specification Sheet
MG100 and MS100 Fixed Ell Main Line Flowmeter


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better.
Range 2” to 24”
Maximum
Temperature (Standard Construction) 160°F constant
Pressure Rating 150 psi
Materials

Spool Epoxy-coated carbon steel
Coating Fusion-bonded eposxy
Body Epoxy-coated carbon steel pipe conforming to A.S.A pipe schedules
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel
Magnets (Permanent type) Alnico

Bearing Housing • For models 2” to 16”: 304 stainless steel standard, 316 stainless steel optional
• For models 18” and larger: Brass standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter. High temperature impeller is optional.
Options

• Extended warranty
• High temperature construction 180°F
• Marathon bearing assembly for higher-than-normal flowrates 4” and larger
• Digital register available in all sizes of this model
• A complete line of flow recording/control instrumentation
• Register extensions available
• Certified calibration test results
• Canopy boot
• Non-standard laying lengths


















Page 2 24517-17 Rev. 2.3 | 23MAR2020

Specification Sheet
MG100 and MS100 Fixed Ell Main Line Flowmeter


DIMENSIONS





FLOW

















MG100 / MS100 DIMENSIONS
inches 2 2 ½ 3 4 6 8 10 12 14 16 18 20 24
Meter Size
mm 50.8 63.5 76.2 101.6 152.4 203.2 254 304.8 355.6 406.4 457.2 508 609.6
GPM 1016 1016 1016 1270 2286 2540 3175 3810 6350 6985 10160 12065 17780
Minimum Flow
LPS 40 40 40 50 90 100 125 150 250 275 400 475 700
GPM 15.8 15.8 15.8 37.9 75.7 94.6 113.6 157.7 189.3 252.4 315.5 378.5 536.3
Maximum Flow
LPS 250 250 250 600 1200 1500 1800 2500 3000 4000 5000 6000 8500
Maximum Flow w/ GPM
Marathon Bearing 900 1800 2250 2700 3750 4500 6000 7500 9000 12750
Approx. Head Loss in inches 30 30 30 23 17 7 4 3 2 2 2 1 1
Inches at Max. Flow mm 749 749 749 584 432 171 95 70 51 44 38 32 25
GPM/ 250/ 250/ 250/ 1000/ 1800/ 2500/ 3K/ 4K/ 6K/ 8K/ 10K/ 10K/ 15K/
Standard Dial Face*
Gal 10 10 10 100 100 100 1000 1000 1000 1000 1000 10K 10K
Approx. Shipping lbs 17 28 44 53 87 106 140 144 172 181 223
Weight, lbs. kg 7.7 12.7 20.0 24.0 39.5 48.1 63.5 65.3 78.0 82.1 101.2
inches 11 13 14 15 17 19 21 23 26 27 31
H
mm 277 325 352 377 430 480 521 572 648 674 775
inches * See 13 20 20 20 20 20 20 22 22 22 22
L - MG100
mm special note 330 508 508 508 508 508 508 559 559 559 559
inches 13 20 22 22 22 22 22 24 24 24 24
L - MS100
mm 330 508 559 559 559 559 559 610 610 610 610
inches 3.5 4.5 6.625 8.625 10.75 12.75 14 16 18 20 24
O.D. of Meter Tube
mm 89 114 168 219 273 324 356 406 457 508 610
*Indicates the dial face range and multiplier
**Special Note—Reducing ttings incorporating grooves are supplied to adapt the 3-inch model to smaller line sizes.

Larger owmeters on special order.














Page 3 24517-17 Rev. 2.3 | 23MAR2020

Specification Sheet
MG100 and MS100 Fixed Ell Main Line Flowmeter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1
15”
Flow



A





Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions



STRAIGHTENING VANES


Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal
sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can


travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.



















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-17 Rev. 2.3 | 23MAR2020

Specification Sheet
MG100 and MS100 Fixed Ell Main Line Flowmeter


TOTALIZERS

Typical face plates

2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000
500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register




Mechanical Totalizer

The instantaneous owrate indicator is standard and available in gallons per

minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.





Wireless Telemetry

The optional FlowConnect is designed speci cally for wireless telemetry via either

satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.


Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-17 Rev. 2.3 | 23MAR2020



Specification Sheet
MT100 Fixed Ell Threaded End Flow Meter



DESCRIPTION

The Model MT100 is manufactured to comply
with the applicable provisions of the AWWA
Standard No. C704-02 and latest revisions for
propeller type flowmeters.
The threaded ends of the MT100 allow it to be
directly coupled into an existing pipeline.
The carbon steel flow tube has a fusion-bonded
epoxy coating offering excellent corrosion
protection.

As with all McCrometer propeller flowmeters,
standard features include a magnetically
coupled drive, instantaneous flowrate indicator
and straight-reading, six-digit totalizer.


FEATURES

Impellers
Impellers are manufactured of high-impact Typical Applications
plastic, capable of retaining their shape and
accuracy over the life of the meter. The McCrometer propeller meter is the most

Each impeller is individually calibrated at the widely used flowmeter for municipal and
factory to accommodate the use of any standard wastewater treatment applications as well as
McCrometer register, and since no change agricultural and turf irrigation measurement.
gears are used, the MT100 can be field-serviced Typical applications include:
without the need for factory recalibration. • Water and wastewater management

Bearings • Truck loading and discharge
• Sprinkler irrigation systems
Factory lubricated stainless steel bearings are
used to support the impeller shaft. • Drip irrigation systems
• Golf course and park water management
The shielded bearing design limits the entry of • Commercial nurseries
materials and fluids into the bearing chamber
providing maximum bearing protection.
Register
An instantaneous flowrate indicator is
standard and available in gallons per minute,
cubic feet per second, liters per second and
other units.
The register is driven by a flexible steel cable
encased within a protective self-lubricating
liner.
The register housing protects both the register
and cable drive system from moisture while
allowing clear reading of the flowrate indicator
and totalizer.




24517-19 Rev. 2.5 | 23MAR2020

Specification Sheet
MT100 Fixed Ell Threaded End Flow Meter


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 2” to 6”
Maximum
Temperature (Standard Construction) 160°F constant
Pressure Rating 150 psi
Materials

Spool Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Body Fusion-bonded epoxy-coated carbon steel threaded to NPT. (Other thread standards
available)
Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel.
Magnets (Permanent type) Alnico
Bearing Housing 304 stainless steel standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter. High temperature impeller is optional.
Options

• Extended warranty
• Register extensions

• Custom lay lengths
• High temperature construction 180°F
• Marathon bearing assembly for higher than normal flowrates 4” and larger
• Digital register available in all sizes of this model
• A complete line of recording/control instrumentation can be driven from this
flowmeter
• Canopy boot

















Page 2 24517-19 Rev. 2.5 | 23MAR2020

Specification Sheet
MT100 Fixed Ell Threaded End Flow Meter


DIMENSIONS








FLOW














MT100 DIMENSIONS
inches 2 2 1/2 3 4 6
Meter Size
mm 51 64 76 102 152
GPM 35 35 40 50 90
Minimum Flow
LPS 2.2 2.2 2.5 3.2 5.7
GPM 250 250 250 600 1200
Maximum Flow
LPS 15.8 15.8 15.8 37.9 75.7
Maximum Flow w/
Marathon Bearing GPM 900 1800
Approx. Head Loss in inches 29.5 29.5 29.5 23 17
Inches at Max. Flow mm 749 749 749 584 432
GPM/
Standard Dial Face* 250/10 250/10 250/10 1000/100 1800/100
Gal
Approx. Shipping lbs 17 40 42
Weight, lbs. kg 8 18.1 19.1
inches 10 13 14
H
mm * See special note 254 330 356
inches 13 20 22
L
mm 330 508 559
inches 3.5 4.5 6.625
OD up to
mm 89 114 168
*Indicates the dial face range and multiplier
*SPECIAL NOTE — Reducing ttings are supplied to adapt the 3-inch model to smaller line sizes.




















Page 3 24517-19 Rev. 2.5 | 23MAR2020

SMOOTH END Specification Sheet
MT100 Fixed Ell Threaded End Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1
Flow
15”





A





Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions





STRAIGHTENING VANES

Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal

sand separator. These cause swirling flow in the line that affect propeller meters. Well developed swirls can

travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.


















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-19 Rev. 2.5 | 23MAR2020

Specification Sheet
MT100 Fixed Ell Threaded End Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer
The instantaneous flowrate indicator is standard and available in gallons per

minute, cubic feet per second, liters per second and other units. The register is
driven by a flexible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the flowrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a flowmeter’s flowrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be fitted to any new or existing McCrometer


propeller flowmeter.






Wireless Telemetry

The optional FlowConnect is designed specifically for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze flow rate, consumption, and possible
anomalies in an irrigation system.
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-19 Rev. 2.5 | 23MAR2020



Specification Sheet
ML100 Flanged Irrigation Flow Meter



DESCRIPTION

Model ML100 irrigation flow meter is designed
to provide accurate flow measurement at
moderate pressure ratings in an inexpensive
package.
The impeller and drive assembly are removed
and replaced through the open end of the
meter tube.

The ML100 can be field-serviced without the
need for factory recalibration.

FEATURES
Impellers
Impellers are manufactured of high-impact
plastic, capable of retaining their shape and
accuracy over the life of the meter.
Each impeller is individually calibrated at
the factory to accommodate the use of any
standard McCrometer register. Typical Applications
Bearings
The McCrometer propeller is the most widely
Factory lubricated stainless steel bearings are used flowmeter for agricultural and turf
used to support the impeller shaft.
irrigation measurement. Typical applications
The sealed bearing design limits the entry of include:
materials and fluids into the bearing chamber • Center pivot systems
providing maximum bearing protection.
• Sprinkler irrigation systems
Register
• Golf course and park water management
The instantaneous flowrate indicator is
standard and available in gallons per minute, • Drip irrigation systems
cubic feet per second, liters per second and • Gravity turnouts from underground pipelines
other units.
• Commercial nurseries
The register is driven by a flexible steel cable
encased within a protective vinyl liner.
The register housing protects both the register
and cable drive system from moisture while
allowing clear reading of the flowrate indicator
and totalizer.


















24517-18 Rev. 2.2 | 23MAR2020

Specification Sheet
ML100 Flanged Irrigation Flow Meter


SPECIFICATIONS

Performance

• ±2% of reading guaranteed throughout full range
Accuracy /
Repeatability • ±1% over reduced range
• Repeatability 0.25% or better
Range 6”, 8”, 10” 12”
Pressure Rating 75 psi

Materials
Tube Epoxy-coated carbon steel pipe, conforming to ASA pipe standards. Lightweight
irrigation flanges with 150 pound drilling
Spool Carbon steel standard, stainless steel optional
Coating Fusion-bonded epoxy
Body Epoxy-coated carbon steel pipe conforming to A.S.A pipe schedules

Bearing Assembly Impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel.
Magnets (Permenant type) Alnico
Bearing Housing 304 stainless steel standard, 316 stainless steel optional
Register An instantaneous flowrate indicator and six-digit straight-reading totalizer are
standard. The register is hermetically sealed within a die cast aluminum case.
This protective housing includes a domed acrylic lens and hinged lens cover with
locking hasp.
Impeller Impellers are manufactured of high-impact plastic, retaining their shape and
accuracy over the life of the meter.
Options

• Extended warranty
• Register extensions
• Flow straightening vanes
• High temperature construction 180°F
• Marathon bearing assembly for higher than normal flowrates

• Digital register available in all sizes of this model
• A complete line of flow recording/control instrumentation
• Canopy boot




















Page 2 24517-18 Rev. 2.2 | 23MAR2020

Specification Sheet
ML100 Flanged Irrigation Flow Meter


DIMENSIONS



FLOW















ML100 DIMENSIONS
inches 6 8 10 12
Meter Size
mm 152 203 254 305
Minimum Flow. U.S. GPM 90 100 125 150
GPM LPS 5.7 6.3 7.9 9.5
Maximum Flow U.S. GPM 1200 1500 1800 2500
GPM LPS 75.7 94.6 113.6 157.7
Maximum Flow w/
Marathon Bearing GPM 1800 2250 2700 3750
Approx. Head Loss in inches 17 6.75 3.75 2.75
Inches at Max. Flow mm 432 171 95 70
GPM/
Standard Dial Face* 1800/100 2500/100 3K/1000 4K/1000
Gal
Approx. Shipping lbs 50 61 104 125
Weight, lbs. kg 23 28 47 57
inches 6 8 10 12
A
mm 152 203 254 305
inches 0.875 0.875 1 1
B
mm 22 22 25 25
inches 9.5 11.75 14.25 17
C
mm 241 298 362 432
inches 11 13.25 16 19
D
mm 279 337 406 483
inches 16.25 18.5 21.75 24.25
H
mm 413 470 552 616
inches 20 20 20 20
L
mm 508 508 508 508
No. of Bolts Per Flange 8 8 12 12
*Indicates the dial face range and multiplier















Page 3 24517-18 Rev. 2.2 | 23MAR2020

FLANGED Specification Sheet
ML100 Flanged Irrigation Flow Meter


INSTALLATION

Standard installation is horizontal mount. If the meter is to be mounted in the vertical position, please advise
the factory.



PIPE RUN REQUIREMENTS



Confi guration A B

Without straightening vanes 10 1
With straightening vanes 5 1 B
With FS100 Flow Straightener 1.5 1
Flow
15”





A





Elbow shown - Other piping
components can be pumps, valves
and expansions or reductions





STRAIGHTENING VANES

Special attention should be given to systems using two elbows “out of plane” or devices such as a centrifugal

sand separator. These cause swirling ow in the line that a ect propeller meters. Well developed swirls can

travel up to 100 diameters downstream if unobstructed. Since most installations have less than 100 diameters
to work with, straightening vanes become necessary to alleviate the problem. Straightening vanes will break
up most swirls and ensure more accurate measurement. McCrometer actively encourages installing vanes just
ahead of the meter. Straightening vanes are available in weld-in, bolt-in, and the FS100 Flow Straightener.


















Elbows out of plane Bolt-in straightening vanes FS100 Flow Straightener






Page 4 24517-18 Rev. 2.2 | 23MAR2020

Specification Sheet
ML100 Flanged Irrigation Flow Meter


TOTALIZERS

Typical face plates


2500 2500
2000 3000 2000 3000
1500 3500 1500 3500
1000 4000 1000 4000

500 4500 500 4500
0 9 2 5 4 5 0 9 2 5 4 5 7
0 5000 0 5000


Standard register Optional 7-wheel totalizer FlowCom register






Mechanical Totalizer

The instantaneous owrate indicator is standard and available in gallons per
minute, cubic feet per second, liters per second and other units. The register is
driven by a exible steel cable encased within a protective vinyl liner. The register

housing protects both the register and cable drive system from moisture while
allowing clear reading of the owrate indicator and totalizer.







Digital Totalizer



The optional FlowCom register displays a owmeter’s owrate and volumetric
total. Available are optional outputs: scaled pulse and/or industry standard
4-20mA signal. The FlowCom can be tted to any new or existing McCrometer


propeller owmeter.






Wireless Telemetry

The optional FlowConnect is designed speci cally for wireless telemetry via either
satellite or cellular data service. Manual meter reading is never required. It uses
either the mechanical register or the digital register (both shown above).
You can determine how often readings are made and transmitted to the cloud
database, which you can view on a PC or on a cell phone. The viewing utility

provides data tools that can analyze ow rate, consumption, and possible
anomalies in an irrigation system.
Copyright © 2001-2019 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing,
technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Page 5 24517-18 Rev. 2.2 | 23MAR2020