AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] Proposal For Engineering, Procurement & Commissioning Of Rooftop, Grid - Tied Solar PV Power Plant of 160.170KWp and 160.05KWp (DC Capacity) Submitted To Shri Ram Centennial School Sikanderpur, Dayalbagh(9759559494) AGRA ON 01-03-2024


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] INDEX I. DISCLAIMER ................................................................................................4 II. AIM OF THE DOCUMENT ............................................................................5 III. SCOPE OF WORK .......................................................................................5 IV. ASSUMPTIONS & EXCULSIONS ..................................................................5 ASSUMPTIONS .................................................................................................5 EXCLUSIONS .....................................................................................................6 V. COMMERCIAL OFFER..................................................................................6 A) PRICE.........................................................................................................6 B) PAYMENT TERMS ......................................................................................7 C) VALIDITY ....................................................................................................7 D) WARRANTY ...............................................................................................7 VI. TECHNICAL OVERVIEW..............................................................................8 A) SYSTEM SCHEMATIC..................................................................................8 B) KEY FACTS OF THE POWER PLANT .............................................................8 VII. SYSTEM DESCRIPTION...............................................................................8 VIII. MAJOR SYSTEM COMPONENTS.................................................................9 A) PV MODULES.............................................................................................9 B) INVERTER.................................................................................................10 C) MODULE MOUNTING STRUCTURE...........................................................11 D) CABLES ....................................................................................................11 E) EARTHING................................................................................................11 F) LIGHTNING ARRESTORS ...........................................................................12 IX. MAJOR BILL OF MATERIALS (INDICATIVE)................................................12 A) CONTROL PLAN .......................................................................................13


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] B) QUALITY CONTROL PLAN.........................................................................13 C) QUALITY CONTROL PLAN - ELECTRICAL ...................................................13 X. SAFETY RULES ..........................................................................................13 XI. TIME SCHEDULE ......................................................................................14 XII. FORCE MAJEURE .....................................................................................14 XIII. EFFECTIVE DATE OF ORDER .....................................................................15 XIV. JURISDICTION..........................................................................................15 XV. ASSIGNMENT/SUBCONTRACTING ...........................................................15 XVI. RESOLUTION OF DISPUTES AND ARBITRATIONS......................................15 CONTACT DETAILS ..........................................................................................15 XVII. ABOUT THE COMPANY .....................................................................16 A) CORPORATE OVERVIEW ..........................................................................16 B) STRATEGY AND VISION............................................................................16


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] II. DISCLAIMER This proposal is proprietary to AAKAR POWER. It is supplied in confidence and should not be disclosed, duplicated or otherwise revealed in whole or in part to any third parties without the prior consent of AAKAR POWER. The Company has developed all information and opinions contained in the document. Information on the projects contains Intellectual Property owned by AAKAR POWER, and as such may not be made available to other third party vendors without our prior written approval. No representation or warranty, express or implied, is given by the Company or any of their respective directors, partners, officers, affiliates, employees, advisers or agents (and any warranty expressed or implied by statute is hereby excluded) as to the accuracy or completeness of the contents of this document or any other document or information supplied, or which may be supplied at any time or any opinions or projections expressed herein or therein, nor is any such party under any obligation to update the document or correct any inaccuracies or omissions in it which may exist or become apparent. In particular, for reasons of commercial sensitivity, information on certain matters has not been included in the document. Such information may be made available at a later stage. Please note that information in this document is intended to provide a broad-level outline of the project of the plant. The capacity assessed shall be subject to Site survey & Detail Engineering. Techno commercial proposal submitted herein is subject to change after detailed site survey & Engineering.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] III. AIM OF THE DOCUMENT This document is aimed at providing the Techno-Commercial offer of 160.170 KWp and 160.05KWp DC Capacity solar roof top power plants based on the initial discussion with the Management/ Technical Team of the company. The Techno Commercial proposal submitted herein is subject to the Detailed Site Survey & Engineering. IV. SCOPE OF WORK For AAKAR POWER Comprehensive Engineering, Procurement and Construction Contract (EPC) including: Design, Engineering, Testing, including developing overall plant layout showing all walk ways, cable trenches, auxiliary facilities. Procurement of Modules, Inverters, Cables, Junction box, module’s structure etc. Construction/Erection of panels, inverters. Power Evacuation cable from ACDB point near to Inverter outlet onwards. Delivery of evacuation of electricity at 415V output from Solar Power Plant. (Max 100mtr Al Ar Cable shall be in the scope of APSPL. If the cable length exceeds 100 mtrs, the extra cost shall be in the scope of Customer. All civil works including structures and foundations required for mounting the solar modules. Assistance for claim of subsidy to client. Client shall claim the subsidy. (If Applicable) Assistance towards Net Metering documentation. For Owner/Developer/Client Provide site (shadow free area @80 sq.ft per kWp capacity) and diagrams with true South. Provide control room / isolated space for inverter and other electrical (approx. 100 sq.ft well ventilated room, if required). All necessary clearances to work inside the premises. Site and related scopes like right of way, access to site. Site Development activities including but not limited to drainage, fencing, support Infrastructure, panel cleaning arrangements, internal lighting and fire protection equipment. Approval for Grid Connectivity from Discom / Net Metering Arrangements. Power and soft water for construction & module cleaning etc. for cleaning related activities. Cleaning of Modules shall be in the scope of Customer. AAKAR POWER will provide training to client’s employee. Fire & Allied Insurance + Third Party Insurance after commissioning of Plant V. ASSUMPTIONS & EXCULSIONS ASSUMPTIONS The client shall provide suitable space for setting up aforementioned system with unrestricted access.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] Written consent / permission to access the roofs for solar PV power plant installation and Maintenance activities (if, given to AAKAR POWER). Clear mounting area is available for the PV on the roof without shading/obstruction. The indicative power plant capacity is considered based on initial discussions, this is to be confirmed post detailed site survey and Engineering. Assumed roof can withstand the dead + live load of modules. The sufficient area is available for inverters and ACDB / ACCB. Preferred to have control room for mounting inverters and ACDB / ACCB. LAN connectivity for remote plant monitoring system (Weblogger, Data Logger or SCADA which ever applicable as per Inverter Make). Secured storage area for component storage during course of project execution EXCLUSIONS Construction Power & water is in customer scope. Computer / desk top for data logging under customer scope. Post COD soft water and other equipment’s for module cleaning to be arranged by client for the cleaning. AAKAR POWER will provide training to client’s employee for cleaning. VI. COMMERCIAL OFFER a) PRICE a. Total Project Cost on turnkey basis will be -- Sr. Nos ITEM Size RATE Total GST @13.8% Grand Total QTY. (Rs / KW) Rs Rs Rs 1. 160.05KWp SOLAR POWER PLANT with 550 Wp Mono Perc modules 160.05 KWp Rs.29,000.00 Rs.46,41,450.00 Rs.6,40,520.00 Rs.52,81,970.00 2. 160.170KWp SOLAR POWER PLANT with 570 Wp TOPCON modules 160.170 KWp Rs.30,000.00 Rs.48,05,100.00 Rs.6,63,104.00 Rs.54,68,204.00 As per the scope of work defined above. b. In addition to the above the client has to pay additional charges towards Net Meter and Net Metering expenses, if required. c. The above price includes breakdown maintenance support for Five year period. i.e. In case of any fault occurring due to negligence in workmanship of our staff, our services shall be free for a period of five years starting from the date of commissioning of the plant.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] d. The above price is exclusive of Taxes -- (GST extra). The GST mentioned above is at the prevailing rate. GST rate at the time of Invoicing shall be applicable on the plant – Any change in the GST rates shall be to the scope of the customer. e. Contract Price shall be inclusive of all transportation and insurance cost till the Project Site only. b) PAYMENT TERMS The terms of payment for the scope of supply as mentioned in this offer are as follows:- 35% of order value in the name of “AAKAR POWER SYSTEM P. LTD.” as advance with confirm Work Order. 60% of order value in the name of “AAKAR POWER SYSTEM P. LTD.” before dispatch of Major Components to site (Structure, Module and Inverter). 5% of order value in the name of “AAKAR POWER SYSTEM P. LTD.” within 30 days from the date of Commissioning (start of power evacuation from solar power system). c) VALIDITY The above quoted price is valid for a period of 30 days from the date of this offer. Thereafter, the same can be extended as mutually agreed upon. d) WARRANTY a. All equipment supplied by us shall carry original equipment warranty terms. Our warranties are not valid for any mishandling, abused wear and tear, sabotage/force majeure conditions. b. This warranty will not cover damages caused due to lightning, storm, over voltage & normal wear & tear as the same will be covered under the Fire & Allied insurance policy and damage policy which has to be taken by the client. AAKAR POWER will not be liable for any damage due to monkeys after installation. c. 90% of the specified minimum output of the module for a 10-year period and 80% of the specified minimum output of the module from 11-25 year period, provided the Modules are maintained clean and area being shadow free.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] VII. TECHNICAL OVERVIEW a) SYSTEM SCHEMATIC A PV grid-tied power plant comprises a limited number of components including modules, mounting structure, inverters, cables, routing, ACCB. Each component designed for your system is detailed within this offer. b) KEY FACTS OF THE POWER PLANT Plant capacity in kWp : 160.170 KWp and 160.05KWp(DC Capacity) PV Technology/ Module : High efficiency Monoperc modules each of 550Wp and 570Wp TOPCON Inverter : String Inverters after detailed engineering Power Evacuation : 415V AC, 3Phase, 50 Hz Estimated Power Output : Minimum of 15% Capacity Utilization Factor. The aforesaid estimated power output shall be subjected to cleaning frequency based on dust accumulation on modules & actual weather conditions. The environment should be free from ash and dust. VIII. SYSTEM DESCRIPTION The Solar Photovoltaic power generator is the total arrangement of PV modules in series and parallel connections. Individual crystalline solar cells are connected together in a module (in series


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] connection), which are hermetically sealed to survive in rugged weather conditions and ensures optimum performance during its long life. The solar array is comprised of solar modules that generate DC electricity in proportion to the amount of sunlight available, generating the most power on a clear day when the sun is at a normal angle to the array. The microprocessor control circuit shall automatically adjust the DC-DC converter to ensure that it should always match to the PV array Maximum Power Point (MPPT) under varying conditions and transfers the maximum possible power to Inverter. The inverter shall convert DC to AC and export it to the grid. The inverter output shall match the grid in voltage, frequency and phase. AC Distribution board is equipped with Bi-directional (Import-Export) Meter to measure the energy generation and export to the grid. Each system comprises of the following components: 1. Solar Module 2. Module Mounting Structures / Racking System 3. Solar String Inverter 4. AC distribution board / AC Combiner Box 5. Cables & Accessories IX. MAJOR SYSTEM COMPONENTS The following are the major systems, sub systems & components that are used for the power plant: a. Solar Module b. Module Mounting Structures / Racking System c. Solar String Inverter d. AC distribution board / AC Combiner Box e. Cables & Accessories a) PV MODULES Salient Features: High-Efficiency Polycrystalline Solar Cells; Passing mechanical load test according to IEC 61215(advanced test); Passing Salt mist corrosion test as per IEC 61701. Tested to withstand Wind load up to 3800Pa / Snow load up to 5400Pa The high-transparency low-iron tempered glass allows maximum light permeability while enhancing stiffness and impact resistance;


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] Integrated bypass diodes to protect the solar cell circuit from hot spots during partial shadowing; The module technology avoids any problems of water freezing and warping; Crystalline Module Technology Power Tolerance Certification Salient features Monoperc and TOPCON 550Wp And 570Wp IEC 61215, IEC 61730 10-year limited product warranty; 25 year manufacturer’s warranty b) INVERTER Salient Features: Peak efficiencies up to 98.5% to maximize harvest. With an appropriate transformer, it can also be adapted to the low voltage grid (LV 480 VAC) Configurable DC voltage ranges and power outputs allow for flexibility for all panel types and installations. Standard 1000 VDC input for long string lengths Maximum Power Point Tracking is designed to meet the latest requirements for quick responses to dynamic weather conditions such as spontaneous cloud cover on a clear day, and reliable day/night detection (active/passive). The utility scale inverters have grid management features that can be adapted to the unique requirements of the utility. With four different ways to provide reactive power control, adjustable settings for Low Voltage Ride Through, ramp parameters for start and stop operations, options to adjust the effective power to stabilize grid frequency, and remote power control, the flexibility of the inverters are unmatched. Integrated industry standard RS485/Modbus communications Inverter Technology Max. Efficiency Recommended PV Power Salient features K-SOLAR/ POLYCAB/Growatt/ EQUIVALENT String Inverter >98% 160.170KWp and 160.05KWp (DC) Refer above


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] c) MODULE MOUNTING STRUCTURE The Mild Steel Galvanized mounting system is a semi rigid structure, the structure is designed to resist the wind load of 140km/hour as per IS-875-part-3-1997 & draft code The coating for the base material shall be hot dipped galvanized of 70 to 80 micron to prevent corrosion. All connections shall be MS galvanized clamps, bolt, nut & washers. The concrete foundation shall be designed for the uplift forces. d) CABLES All cables have been designed to minimize losses and ensure optimal operation even at high temperatures. These cables are extremely robust and resist high mechanical load and abrasion. High temperature resistance and excellent weather proofing characteristic provide a long service life. The proposed cable ratings are tentative only and it can be finalized during detailed engineering. Parameters Specifications Type XLPE/PVC – Armored & Unarmored Short circuit temperature range 250 Deg. C Standard IS 5831/Equivalent Conductor class IEC 60228 Class 5 Material Copper/Aluminium Protection IP 65 Tensile strength 100 N/Sq.mm e) EARTHING Grounding for the DC side will be designed so as to ground the structures and associated components on the DC side. The system will be so designed to keep the resistance below 1 Ohms. This grounding system will provide a safe path for any ground currents. The earth pits will all be interconnected to prevent any high potential build up. Earth mat will be provided in the switch yard for AC side grounding. Suitable number of earth pits will be provided at the Inverter rooms. All AC side earth pits will be suitably interconnected to create a common earth. Structure Material Foundation Max. wind load MS Galvanized Structure for RCC/ Aluminium Structure for Shed For RCC Roof -- Frame sections: MS Galvanized Structure as per IS-2062-1999, IS-2629-1998 Connections: Galvanized steel Fasteners: MS Galvanized./ Aluminium For Shed Concrete Foundations For RCC Roof (N/A for Shed) 140 kmph


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] f) LIGHTNING ARRESTORS The components used in AJB’s and Inverters have inbuilt surge suppressors. Appropriate lighting protection will be provided in a location, covering the entire solar power plant for protection from lighting strikes. X. MAJOR BILL OF MATERIALS (INDICATIVE) Group Description Make Qty Unit 1 Module 550Wp Monoperc and 570Wp TOPCON GAUTAM SOLAR / AUSTRALIAN PREMIUM SOLAR (APS) / INA/ USHA SHRIRAM/ EQUIVALENT 160.170KWp AND 160.05KWp KWp 2 Mounting Structure Module Mounting Structures AAKAR POWER 1 Set 3 Inverter String Inverter with Online Monitoring K-SOLAR/ GROWATT/ POLYCAB/EQUIVALENT 1 Set 4 AC DB 415V – AC Distribution Box AAKAR POWER 1 Set 5 Cables and Connectors DC Cable POLYCAB TYPE-1 / EQUIVALENT 1 Set AC LV Cable POLYCAB / HAVELS OR EQUIVALENT 1 Set Communication Cables Reputed 1 Set Grounding Equipment Reputed 1 Set Connectors, Cable Glands, Cable Ties Reputed 1 Set 6 Miscellaneous Components Earthing System Reputed 3 Set Lightening Arrestor (107 mtr Radius) Reputed 1 Set Rubber Mat 1 Set Note: We reserve the right to choose the make or equivalent based upon our assessment at the time of detailed engineering and after conducting detailed site survey.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] QUALITY ASSURANCE a) CONTROL PLAN A full time AAKAR POWER Project Manager will be appointed during the planning and execution of the PV plant. He will be empowered sufficiently to coordinate, implement, maintain and monitor the overall quality issues of the project from the initial stages to final commissioning and handover. b) QUALITY CONTROL PLAN We will establish a fully documented quality plan which, on implementation, ensures that product and service conforms to specific requirements. In order to meet this it will carry out the tests as listed in the tables below. AAKAR POWER will follow appropriate test methodology to carry out these tests in accordance appropriate standards. c) QUALITY CONTROL PLAN - ELECTRICAL Tests on Electrical side are classified into four categories. The same are listed in the table below. Type Test: This test is carried out on one product of the same type. Test certificate from a reputed lab is used to validate this. Routine Test: This test is carried out by the manufacturer during production. Manufacturer test report is used to validate this test. SAT: Site Acceptance Test is carried out during inspection by an AAKAR POWER authorized representative at the project site. XI. SAFETY RULES The objective of the safety policy is to set down in clear and unambiguous terms the Company’s management approach and commitments toward occupational health and safety of persons, workplace conditions and practices. It sets out clearly all individual roles, responsibilities, accountabilities and authorities towards occupational health and safety. The management of AAKAR POWER believes that all "accidents" or “workplace injury” can be prevented and that the safety and health of its employees and contractors are of primary importance in the operation of its business Every effort to address all areas of risk assessment, hazard control and accident prevention shall be made to protect personnel against harm and damage to property The promotion of safe work practices and the proper maintenance of plant and equipment shall be our basic responsibility. All personnel including contractors are accountable for ensuring success through adequate planning, proper organization and strict enforcement and control. Every employee shall recognize their responsibility to ensure their own health and safety and the that of their co- workers The Site Management team shall provide a safe and healthy workplace for all persons. This shall be achieved in conjunction with effective implementation of the AAKAR POWER Occupational Safety and Health Management System program through the consensus effort of Management, Employees and Contractors.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] XII. TIME SCHEDULE The SPV Power plants will be commissioned within 3 months from date of receipt of confirm Work order along with Mobilization Advance. S. N. Work Schedule Stage 1 Site Survey: Site markings, site pictures, Safety, Logistics Planning etc. Stage 2 System Design Module selection Inverter selection Control Panels Design Mounting structure design Cables design, load wiring design, lighting & earthing system design Civil-structure foundation design Stage 3 Document Approvals from client: Drawings and datasheet approvals for the all components Stage 4 Sub-Contractor finalization for Civil Works, MMS, DC & AC Works Vendor finalization for all components (Such as SPV modules, inverter, cables etc.,) Stage 6 Procurement Activities Stage 7 QA inspection before delivery Stage 8 Delivery of materials to site Stage 9 Project Management Activities Initial Activities- Team Mobilization / Deputation & Arrangement for local stay etc Execution Activities; Site preparation Construction of foundations for Module Mounting structures Installation of module mounting structures Installation of modules Erection of electrical components & cabling Grid synchronization & net metering system (if applicable) Stage 10 Testing, Trail Runs & Final Commissioning Stage 11 Customer Approval / Acceptance & Document submission (As built drawings) XIII. FORCE MAJEURE Force Majeure is herein defined as any cause which is beyond the control of the Contractor or the Owner as the case may be, which they could not foresee or with a reasonable amount of diligence could not have foreseen and which substantially affect the performance of the Contract, such as: Natural Phenomena, including but not limited to floods, droughts, earthquakes and epidemics; Acts of any Government, domestic or foreign, including but not limited to war, declared or undeclared, priorities, guarantees, and embargoes


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] Third party actions which prevent the Contractor from the performance of his obligation under the Contract. Provided either party shall within fifteen (15) days from the occurrence of such a cause notify the other in writing of such causes. XIV. EFFECTIVE DATE OF ORDER Effective Date shall be the date of the release of Mobilization Advance along with Work Order. XV. JURISDICTION Any disputes relating to this Contract shall be subject to the court of competent jurisdiction situated exclusively within the limits of city of Agra (Uttar Pradesh, India). XVI. ASSIGNMENT/SUBCONTRACTING We may subcontract part of the contract to the sub-contractors and other equipment manufacturers, provided it meets our design requirement and quality standards. XVII. RESOLUTION OF DISPUTES AND ARBITRATIONS Any dispute or difference arising between the parties shall unless amicably settled, be referred to arbitration under and in accordance with the provisions of Arbitration and Conciliation Act, 1996 as amended from time to time. The venue of the Arbitration shall be Agra (Uttar Pradesh, India). CONTACT DETAILS FOR FURTHER CLARIFICATIONS, PLEASE CONTACT Phone: +91-9319513726 ; 9719077711 Email: [email protected] ; [email protected]


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] XVIII. ABOUT THE COMPANY a) CORPORATE OVERVIEW The Company has been set up with the objective to be the most reputed and ethical player in the low carbon economy business and Provide cost effective solutions to the customers through renewable energy, innovative technologies and energy efficiency. The company is a complete turnkey solution provider in the Solar Photovoltaic sector. • AAKAR POWER is a Solar Power project development and operating company created to leverage the large scale solar build-out projected in India. • Creates turn-key Solar Power projects with all permits, licenses, sites, interconnectivity and vendors. • Has a fully deployed project development and operations team to provide best-in-class solutions from planning through procurement, development and installation. • Capability to provide clients with fully developed turn- key solutions for their power needs. • Combine best practices in operations and technology leadership with deep local relationships. The management of AAKAR POWER strives to contribute as a total solution provider in the renewable energy and energy management domains thereby contributing in the global efforts of a cleaner & greener world. Our founders and business partners have helped organizations and companies to achieve their energy efficiency and power reliability mandated goals and objectives. We are committed to delivering products and services that help protect and preserve the world's most precious resources. You can trust us for accurate information, trustworthy tools, and reliable resources to help you make the right energy decisions. “We are differentiated by deep industry knowledge and practical experience that is unconstrained by conventional thinking.” b) STRATEGY AND VISION AAKAR POWER understands that solar power is not just about environmental sustainability but also has a significant social and economic impact. For India to achieve its goal of 20% of power generation from renewable sources the needs of the whole of society must be addressed.


AAKAR POWER SYSTEM P. LTD._______ Energising Lives __________________________________________________________________________________ HATHRAS ROAD, NEAR CANARA BANK, AGRA, (U.P.) - 282006 Ph -- +91-9319513726 ; 9719077711 ; 9719002120 Email : [email protected] ; [email protected] It is not reasonable to expect any government to provide high levels of subsidies indefinitely. It is neither politically nor economically sustainable. Our Strategy is to do so by growing solar power to an industrial scale which can compete effectively with existing generators. Our Vision, therefore, is a form of energy which is competitively priced, renewable and produced in harmony with nature. This in turn will benefit consumers and provide attractive returns to investors. Gaining scale brings a number of benefits: Helps to achieve India’s 20% renewable energy target; Reduces the cost per unit of supply; Supports the development of a local solar industry in India; Provides large scale skilled employment in a number of local industries; Offers additional energy security for India; Make solar a mainstream form of energy generation; With the Indian government’s objective of achieving 100GW of renewable power generation by 2022, the case for an integrated solar PV company is extremely compelling. India stands to benefit not only from the development of an indigenous solar power industry but also an increase in the number of highly skilled jobs and capital investment. AAKAR POWER Advantages: At AAKAR POWER we believe Reliability, Cost and Price should be addressed together, to provide the customer with the best economical and operational fit for every facility AAKAR POWER offers significant advantages to its customers.