Tacera Cut Sheets

Tacera Cut Sheets

TOUCH SCREEN
CARE STATION
IP-TSNS/M-18
• Background noise-canceling handset to guarantee the
best audio quality

• Ultra-slim design for healthcare applications

• SSD storage for best performance and reliability

• High resolution, flat touch screen designed for easy cleaning

Innovative, Sleek Design

Austco’s Care Station is used for systems with nurse
call intercoms and designed for use with Austco’s Pulse
Care software solution.

The Care Station features a background noise-canceling
handset to guarantee the best audio quality for calls to
other locations.

Audible tones will sound for the highest priority alarm in
the alarm list.

Austco’s Care Station features a 43mm thin body
enclosure, USB 3.0, and dual isolated Ethernet, which
lets hospitals separate and manage internal and external
network traffic.

Designed for applications in hospitals, aged care
facilities, and treatment centers.

Features

• Ultra-slim design for healthcare applications

• High resolution, flat touch screen for easy cleaning

• SSD storage for best performance and reliability

• Background noise-canceling handset to guarantee the best
audio quality for calls to other locations

• Dual isolated Ethernet for network traffic management and
data security

www.austco.com CS-002, Rev. B

Natural Viewing Experience
with 16:9 18.5" Display

SPECIFICATIONS

Hardware CPU Intel ® Apollo Lake N4200 (2M Cache, up to 2.5 GHz)
Memory 4 GB
Display
Touchscreen Primary Storage SSD 32 GB
I/O Ports Size
Max Resolution 18.5" W TFT LED
Audio 1920 x 1080 FHD
Network Luminance
Software Contrast Ratio 350 cd/m2
Mechanical 1000:1
Type
Projected Capacitive
USB 3.0
USB 2.0 1 (Rear)
Audio Jack (TRRS) 2
Handset Out (RJ-12) 1
DC-in 1
Speaker 1
Internal Microphone 3 Watt x 2
LAN (Isolated) 1

Operating System (OS) Isolated RJ-45 (10/100/1000 Mbit) x 2

Mounting Windows 10 LTSB 2016
Dimensions ( W x H x D)
Weight VESA 75 x 75 mm & 100 x 100 nn
466.4 x 311.5 x 43 mm (18.4” x 12.3” x 1.7”)
Options Handset Net Weight (w/o Adapter): 8.58 lbs, 3.89 kgs
Power Supply Gross Weight: 13.1 lbs, 5.94 kgs
AC/DC Adapter Included
Environment Input Voltage
Output Voltage 100 ~ 240 VAC, 1.1 – 0.45 A @ 47-63 Hz
IT or Medical: 18-19 VDC, 3.42 A
Operating Temperature
Vibration 0 - 40° C (32 – 122°F)
Shock 1G
EMC and Safety Certifications 10 G Peak Acceleration (11 ms duration)
CE, FCC, CCC, CB, UL ITE and Medical, EN 60601-1 and IEC 62368, BSMI

ORDERING INFORMATION

Product Code Description Order Options

IP-TSNS/M-18 Touch Screen Care Station N/A
IP-TSNS/M-18 Desk Stand Desk Stand for 18” Touch Screen Care Station N/A
IP-POWERCORD-T/M-EURO Power Cord specific for Europe Union (EU), non-UK countries 1.83 M for ITE N/A
IP-POWERCORD-T/M-UK Power Cord specific for United Kingdom 1.83 M for ITE N/A
IP-POWERCORD-T/M-AUS/NZ Power Cord specific for Australia/New Zealand N/A
IP-POWERCORD-T/M-USA Power Cord specific for United States of America 1.83 M for ITE N/A
(bundled with TSNS; purchase only for spares)

Touch Screen Care Station, 18 Inch, Includes Audio Handset, Purchase Desk Stand Separately, Excludes Software License

© 2019 Austco Communication Systems Pty Ltd.
All rights are reserved.
Austco Communication Systems Pty Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

TOUCH SCREEN
CARE STATION
IP-TSNS/M-18/NA (NON-AUDIO)

• Ultra-slim design for healthcare applications

• SSD storage for best performance and reliability

• High resolution, flat touch screen designed for easy cleaning

• Fanless design for quiet operation

Innovative, Sleek Design

Austco’s Care Station is used for systems without nurse
call intercoms and is designed for use with Austco’s
Pulse Care software solution.

Audible tones will sound for the highest priority alarm in
the alarm list.

Austco’s Care Station features a 43mm thin body
enclosure, USB 3.0, and dual isolated Ethernet, which
lets hospitals separate and manage internal and external
network traffic.

Designed for applications in hospitals, aged care
facilities, and treatment centers.

Features

• Ultra-slim design for healthcare applications

• High resolution, flat touch screen for easy cleaning

• SSD storage for best performance and reliability

• Dual isolated Ethernet for network traffic management and
data security

• Fanless design for quiet operation

www.austco.com CS-003, Rev. B

Natural Viewing Experience
with 16:9 18.5" Display

SPECIFICATIONS Intel® BayTrail Celeron® J1900
2.0 GHz (Quad-Core)
CPU
Basic Frequency 2MB
L2 Cache 4GB (1 x SO-DIMM DDR3L 1333 MHz up to 8 GB)
Memory 1 x 2.5 internal SATA HDD bay
HDD 2 x Gigabit Ethernet ports (RJ-45)
Network 1 x RS-232
1 x RS-232 / 422 / 485
Processor I/O Ports 5 x USB 2.0 / 1 x USB 3.0
System 2 x Gigabit Ethernet (RJ-45)
1 x HDMI
OS Support Stereo Speaker Audio Line-out x 1, Mic-in x 1
Environmental BUS Expansion 1W x 2
Specifications Mounting Full-size MiniPCIe/mSATA
Dimension (W x H x D) VESA 100 x 100
Power Supply Weight 475 x 295 x 43.5 mm (18.7 x 11.6 x 1.71 in)
5 kg (176.37 oz)
LCD Display Operating Temperature Win 10 IoT Enterprise
Relative Humidity 0 ~ 40° C (32 ~ 104° F)
Touch Screen Vibration 10 ~ 95% @ 40° C non-condensing
Shock 0.5G
EMC and Safety Certifications 10 G peak acceleration (11 msec. duration)
Front Panel Protection CE, FCC, UL, CCC CB,BSMI
Input Rating IP65/ NEMA4 Compliant
12 V/7 A (84W ITE Adapter)
Power Consumption *12-30V Optional
Typical 32W
Size Max. 70W
Max Resolution
Max Color 18.5" TFT LCD
Pixel Pitch (um) 1366 x 768 (FHD 1920 x 1080 Optional)
Brightness (cd/m2)
View Angle 16.7M
300(H) x 300(V)
Type 250 (Typical)

Light Transmission 170°/160°
Controller
Analog Resistive 5-wires (Res. Flat Glass) / Projected Capacitive Touch
Panel (Pcap. Flat Glass) / Glass Panel
Res. Touch : 80% ± 5% / P-Cap Touch : 90% ± 2%
COM interface / USB interface

ORDERING INFORMATION

Product Code Description Order Options

IP-TSNS/M-18/NA Touch Screen Care Station (excludes voice calls) N/A
IP-TSNS/M-18 Desk Stand Desk Stand for 18” Touch Screen Care Station N/A
IP-POWERCORD-T/M-EURO Power Cord specific for Europe Union (EU), non-UK countries 1.83 M for ITE N/A
N/A
IP-POWERCORD-T/M-UK Power Cord specific for United Kingdom 1.83 M for ITE N/A
IP-POWERCORD-T/M-AUS/NZ Power Cord specific for Australia/New Zealand N/A

IP-POWERCORD-T/M-USA Power Cord specific for United States of America 1.83 M for ITE
(bundled with TSNS; purchase only for spares)

Touch Screen Care Station, 18 Inch, Non-Audio, Excludes Software License

© 2019 Austco Communication Systems Pty Ltd.
All rights are reserved.
Austco Communications System Pty Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

ANNUNCIATOR
DISPLAY

IP-WN-DD-2

• High resolution support for clear, legible alarm displays
• Compact and fanless for quieter operation
• Multi-row color text secondary annunciator with audio chimes
• Integrates with Tacera Nurse Call system
• DVI-I/VGA video output

Annunciator Display IP-WN-DD-2 Display Driver Front View

The Annunciator Display is a device that can turn a Full HD LCD
screen into a secondary annunciator on the Tacera Nurse Call system.
The IP-WN-DD-2 is lightweight, web-based, and is remotely
administered/managed.
Healthcare personnel can view multiple alerts without scrolling and
if the monitor has built-in audio capability, the nurse call chimes can
be played through the unit. The IP-WN-DD-2 can be configured to
only receive alarm information from certain locations depending on
the Healthcare facility's needs.

Enhanced Software User Interface Tacera Annunciator Display
Alarm
The new software user interface is clear and legible, allowing users to Acknowledgement
easily read the alarms list from far distances. The Tacera Annunciator
Display can show a clock when no calls or slides are active. The clock CS-004, Rev. C
has customizable features such as 12- or 24-hour formatting, showing
or hiding seconds for digital format, and improved time sync accuracy
with other Austco systems.
The Annunciator displays a confirmation of alarm acceptance by staff
which helps improve staff efficiency by focusing on alarms that have
not yet been accepted to improve staff response times.
Alarm list behavior, including fonts and the option of a user defined
slide show, can all be defined with a simple web interface.

Safe and Reliable

The device has been designed and manufactured to meet international
electrical isolation standards. The design of the IP-WN-DD-2 maintains
the monitor/TV’s integrity and warranty, as it requires only video/audio
connection.
www.austco.com

SPECIFICATIONS

Feature escr on
Height
Width 2 mm 2.44 in
Depth
Weight 1 2 mm . in
Mounting
210 mm .2 in
Housing
Cables . lbs without cables

nvironment Note All the following options must be purchased from a rd party manufacturer that provides
M 0 chassis mounting options.
Display Resolution
Display Outputs ptions are
Audio DIN-RAIL mounting vertical and horizontal
Configuration Wall mount brackets
Network V SA 100 x 100 mm . 4 x . 4 in or x mm 2. x 2. in . A aches in the back of a
monitor.
S
perating System Metal case
Power For HDMI connection, an adapter is required not provided . This may be a DVI-D to HDMI adapter
Power On or a VGA to HDMI adapter, both with or without analog audio.
Cooling
Compliance Temperature 0 C to 40 C 2 F to 104 F
Humidity 10 to 0

Full HD 1 20 x 10 0p suits monitors 24 and larger
1x DVI, 1x VGA

1x Audio TRS ack

Web Interface

thernet 10/100
Pre-set to static 10.2 .2 .10 subnet mask 2 .2 .2 .0

4 x S 2.0
Linux-based
Multi-country AC adapter I C plug types A, C, G and I 12 V
Auto boot application

Fanless

Designed to comply with

• AS 4 0 -1 Personal Reponse Systems
• AS/N S 1000. . 2012 lectromagnetic Compatibility
• AS/N S CISPR 2 lectromagnetic Compatibility of Multimedia quipment mission

Requirements
• HTM 0 -0 edhead services
• CAN/CSA C22.2 No. 0 01-1-14 2004 Safety Requirements for lectrical quipment for

Measurement, Control, and Laboratory se
• C Mark of uropean Conformity
• RoHS Restriction of Hazardous Substances

ORDERING INFORMATION

Product Code escr on Order ons
IP-WN-DD-2 Annunciator Display Driver Monitor specified by site must be purchased separately.

Software license is required. Contact your Austco
representative for more information.

201 Austco Communications Systems PT Ltd.
All rights are reserved.
Austco Communications Systems PT Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without
notice or obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

IP-TALKTWO
INTERCOM MODULE
IP-TALKTWO/VOIP
• Full-duplex speech capability IP-TALKTWO/VOIP/BS
• VoIP communications powered by PoE
• Web-based setup interface Impact
• Integrated with the Tacera Nurse Call System resistant ABS

• Active call indicator plastic

Speaker

TalkTwo/VoIP Microphone Active call
indicator
A flush mounted intercom module that provides IP-TALKTWO/VOIP
full-duplex audio communication between healthcare Active call
staff and patients/residents in their room. It is Impact Speaker indicator
integrated with the Tacera Nurse Call System to resistant ABS
provide seamless communication to a specific location
when an alarm is activated. plastic
The intercom fits into a standard electrical wall box for
quick and easy installation. Manufactured from an
impact resistant polycarbonate / ABS plastic blend,
the intercom features mounting hardware to
maximize the life of the module.

Two-way Audio
Communication

When a patient or resident activates a callpoint, the
nurse call system displays the alarm with the
extension number of the room where the alarm
was activated. By clicking on the extension number
on either the nurse station or the mobile app, a
voice call is connected to the room.

Microphone

www.austco.com IP-TALKTWO/VOIP/BS

CS-005, Rev. C

SPECIFICATIONS

Feature c i tion c i tion

Height 116 mm (4.57 in) 5 mm . in
Width 76 mm (2.99 in) 5 mm . in

epth 45 mm (1.77 in) 45 mm (1.77 in)
Weight 150 grams (5.29 oz) 0 . grams . oz
Mounting Screw on
Plate Austco Modular Plate Screw on
Wall Box Size Standard Size Wall Box Austco Modular Plate
Housing Wall Box Standard Australian Size Wall Box
Connectors Modular P C Wall Box
Cable Modular P C
Temperature CAT STP cable
0 - 50 C - CAT STP cable
umidity Range 0 - 50 C -
Power 0- 5 Non Condensing
PoE 0 . af or later power 0- 5 Non Condensing
Compliance PoE 0 . af or later power

CSA . No. - - - Audio/Video, Information and Communication Technology Equipment - Part
Safety Requirements

EN 550 0 5 Electromagnetic Compatibility of Multimedia Equipment

EN 550 5 0 Electromagnetic Compatibility of Multimedia Equipment - Immunity Requirements

EN 000- - 0 Electromagnetic compatibility EMC . imits. imits for harmonic current emissions
equipment input current A per phase

EN 000- - 0 Electromagnetic Compatibility EMC - PART - imits - imitation of Voltage Changes,
Voltage luctuations and licker in Public ow-Voltage Supply Systems, for Equipment with Rated
Current A Per Phase and Not Sub ect to Conditional Connection

CE Mark European Conformity

IEC - Audio/video, information and communication technology equipment - Part Safety requirements
RCM Regulatory Compliance Mark

ORDERING INFORMATION

Product Code c i tion Or tion
IP-TALKTWO/VoIP IP TalkTwo VoIP Intercom N/A

IP-TA TW /VoIP/BS IP TalkTwo VoIP Intercom, British Style N/A

0 Austco Communications Systems PT td.
All rights are reserved.
Austco Communications Systems PT td. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Enables direct integrations to other systems WEB SERVICES
IPC-WEBSERVICES

• Does not require middleware

• Can accept alarms from other systems, such as fire or
security, and export alarms to other systems, such as EMR

• Provides facilities/vendors with a standard interface to
request alarm data

• RESTful web services deliver scalability and flexibility

Web Services Overview

The Web Services API provides an open interface between the Tacera Nurse Call System and software clients that integrate
with it. It allows for the direct integration of various healthcare information systems (HIS) such as EMRs, ADT, PES and RTLS
systems. This solution addresses the interoperability challenges of HIS systems needing to share information with other
internal systems. This leads to enhanced quality and safety, convenient access to healthcare services and reduced costs.

Advantages of Web Services RTLS

Interoperability Smart pumps, Smart Beds
other devices Scheduling,
In healthcare, interoperability is the ability for different information Patient Assignments
technology systems and software applications to communicate, Engagement
exchange data, and use the information that has been exchanged. Systems ADT
(PES)
The push for advanced healthcare technology has resulted in nurse
call features intended to facilitate caregiver and patient Fire Alarms ALARM DATA
communication as well as maximize clinical workflow. While the
technology still includes a call bell, new nurse call systems are far EMR
more complex and feature-rich.

Additional systems such as real-time location (RTLS) and
admit/discharge/transfer (ADT) systems are now expected to
integrate seamlessly with the nurse call system.

With an increased focus on patient satisfaction, it’s more
important than ever to create an environment of quality customer
service, fast response times and superlative nursing care.

Standard Web Interface New Additions

Web Services allow the business logic of many different In addition to RTLS and basic alarm data, the Web
systems to be exposed over the web. This gives the Services API has been enhanced to allow:
applications the freedom to use the Web Services that they • Third-party applications to take alarm actions like
need. Instead of re-inventing the wheel for each client
system, you only need to include additional Accept, Reject or Escalate.
application-specific business logic on the client side. • Auxiliary events from patient pendant buttons. This

Further details are available in SIM-027, Tacera Web allows third-party applications to take mapped
Services API Developer Guide. actions such as lights, fan, and/or window blinds
control.
www.austco.com
CS-006, Rev. A

12V Power Supply

IP-PSA-ALT-12V/24V

• 12V Power Supply
• This power supply is used for the Medicom Nurse Call solution

Features

• Visual fault indication
• Relay Fault Rebooting
• Additional output for Fire Alarm Interface (FAI)
• Short circuit protection
• Thermal protection
• Reverse polarity protection (PTC)
• UL Listed
• CSA Certified
• Limited warranty: Lifetime

SPECIFICATIONS

Feature Description

Height 4"
Width 11"
Depth 15"
Weight
Input voltage 15 lbs. (Approximately)
Input current 110V AC
Output voltage 3.30 A @ 110 V

12V DC @ 8 A

ORDERING INFORMATION

Product Code Description Order Options
IP-PSA-ALT-12V/24V 12V Power Supply N/A

www.austco.com or call to speak to our experts about a CS-023, Rev. A

ARK-1 NURSE CALL
APPLIANCE

IP-ARK-1

• The first Nurse Call Appliance available on the market
• Smaller form factor, can be rack- or wall-mounted
• Industrial-grade – built for reliability and durability

Austco ARK-1

The Austco ARK-1 Nurse Call Appliance offers a guaranteed
5-year product lifecycle. Nurse Call systems need to operate
reliably for a long period of time in harsh environments,
including extreme temperatures, areas of electromagnetic
interference (EMI), vibration, dirt, moisture and corrosion. It
is important that operations personnel purchase equipment
specifically designed for these harsher environments and
high availability. While traditional commercial solutions are
ideal for low-reliability enterprise applications, they may
not necessarily be designed to withstand severe conditions
as those found in most healthcare environments.
With its small form-factor, the ARK-1 is ideal for facilities
with limited server space which do not want to sacrifice
performance or durability. The ARK-1 can be rack or
wall-mounted, is developed to Austco R&D specifications
and is fully supported by Austco.
Austco’s newly released ARK-1 will supersede legacy
ACS-110 hardware.

Ruggedized for High Reliability and
Greater Uptime Seamless Redundancy

Built specifically for 24/7 mission critical operations in The ARK-1 offers high availability and a long lifecycle,
extreme conditions of temperature, humidity and dust making it perfect for healthcare environments requiring
while providing a high level of reliability, robustness and complete reliability and high performance.
performance. Use of all industrial grade components Austco’s ARK-1 is fully scalable and has the ability to
and fanless design, the ARK-1 has been engineered for perform as a primary and secondary node, providing full
reliability in harsh environments. redundancy capabilities and reduced downtime.

www.austco.com CS-025, Rev. F

er rmance ndustr al
mputin

Featuring an advanced industrial grade design encased in an
aluminum housing, the entire system is CB, U , CCC, BSMI,
and CE/FCC Class A rated with added protection from shock,
vibration, water and dust, making the ARK-1 the ideal
system ensuring patient safety in a wide range of
environments requiring uninterrupted operation.

SPECIFICATIONS

rocessor System CPU Intel i-5-4300U Dual Core
ower Requirement Power Input Voltage 12V DC
Mechanical Input current is 5 Amps
Construction Aluminum Housing
Environment Mounting Wall Mounting (standard), Rack Mount Kit available (optional)
Dimensions (W x H x D) 223 x 46.6 x 133.0 mm (8.69” x 1.81” x 5.18”)
Regulation
Graphics perating Temperature With extended temperature SS/mSATA/RAM -20 55 C with 0.7 m/s air ow
Storage Temperature -40 5 C (-40 1 5 F)
Relative umidity
5 40 C (non-condensing)
ibration during peration With mSATA/SSD rms, IEC 00 -2- 4, random, 5 500 , 1 hr/axis
Shock during peration With mSATA/SSD 0 , IEC 007 -2-27, half sine, 11 ms duration
EMC CE/FCC Class A, CCC, BSMI
Safety U , CCC, BSMI, CB
VGA Up to 1 20 x 1200 at 0

ORDERING INFORMATION

Product Code escr pti n Order pti ns
IP-ARK-1 Appliance IP-ARK-1-RACK - Rack mount enclosure sold separately.

201 Austco Communications Systems T td.
All rights are reserved.
Austco Communications Systems T td. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

PATIENT STATION

IP-PST2

• Full Duplex VoIP for 2-way speech - Improves patient/
resident and staff communication

• Simplified cabling - Cabling and infrastructure is reduced
to only structural cabling and a PoE switch

• 3 configurable alarm buttons - Provides flexibility for
different call types

• A single Patient Station for either single or double bed rooms -
Provides a complete in-room communication solution

Description

The Tacera Patient Station (IP-PST2) is a wall or bedhead unit that
provides a complete in-room patient call and audio solution.
Multiple patient/resident handset sockets allow the patient
station to support one or two beds per room. The device serves
as an IPnet Room Controller supporting all current IPnet device
types.

The IP-PST2 is also compatible with digital pendants, including Din
Austco’s Entertainment Multifunction Handset (IP-EMH) which Sockets x 2
offers a sophisticated television patient entertainment system
interface along with up to four nurse assistance buttons and up Two-Way Multifunctional
to four environment buttons for lights, fans, blinds, or air Audio Nurse Call
conditioners. Buttons

Highly Configurable

The IP-PST2 is configurable for use as either a single or double bed
station. Comprising of a single module with four buttons, nine status
LED’s, two standard ¼” jacks and two 8 pin DIN sockets the IP-PST2
can be easily configured for use with standard call cords, pillow
speakers, and external alarm devices such as infusion pumps or a
combination of all three.

Easy to Identify and Use Standard ¼"
Jacks x 2
Call activation is performed by pressing one or more of the three
call buttons (labelled with its function). Additional room or ensuite
speech or non-speech call points can be connected directly to the
Patient Station via its 2 IPnet patient area network ports.

www.austco.com CS-028, Rev B

eatures and esthetics The IP-PST2 is designed to meet the re uirements of
any modern healthcare facility with features such as
The call buttons feature so touch” operation and are Clean Mode”, Cord ut” notification on sockets
manufactured with an anti-bacterial additive as an without the need for dummy plugs, automatic
infection control measure. Backlighting of the call Entertainment Muting”, and built-in Bed Interface”
buttons provides for easy location and operation at functionality. Its slim, unobtrusive style and design
night. An audible tone sounder and visual reassurance with so curves ensures maximum patient safety
LEDs is standard. while maintaining Austco’s uni ue style.

SPECIFICATIONS

Feature Description
Height
8 mm ( . in)
idth
Depth mm ( . 2)

eight 28 mm ( . 0)
Mounting Method
0 grams ( . o )
all Box Si e
Temperature Wall Box
Humidity Range
Connectors Australian or North American Single or Double ang

Cable Si es 0 - 0 C (32 22 F)

Current Consumption 0 8 Non Condensing
Voltage
Compliance Two DIN8 connectors
Three RJ sockets two Callpoint (IPnet), one Ethernet/PoE

ne -pin Communication port
Two RJ for AM-TVCV

ne 2-position screw terminals for additional 2 V power if re uired
Two 3-pin Header for RL
Two .3 mm (0.2 -inch) pendant connectors

Power Two-wire 2mm (American ire auge (A ) max
RL ne 3 x /0. mm multi-core cable (optional RL -Cord cable)
Callpoint Controller Two pairs of CAT /CAT
AM-TVC Four-wire modular
/0. mm
EMH 2m ( . ), 8-core multi-strand, double-insulated white PVC
Pendant 2m ( . ), three-core multi-strand, double-insulated white PVC with large smooth plastic linen clip

Standby 0 mA
During Intercom call 22 mA (does not include consumption of connected devices)

Power over Ethernet (PoE ) or 2 Volt DC
CAN/CSA C22.2 No. 20 - 3rd Edition
CE Mark of European Conformity
HTM 08-03 (Bedhead services)
RoHS (Restriction of Ha ardous Substances)
L 0 (Safety for Hospital Signalling and Nurse Call E uipment)
L 0 0- (Information Technology E uipment Safety Part eneral Re uirements)
EN 032 20 AC 20
CFR FCC Part Subpart B Class A
EN 02 20 0
L2 0 st edition 20
EN 23 8- 20

ORDERING INFORMATION

Product Code Description Order ptions
IP-PST2 VoIP Patient Station Insert Buttons are ordered separately.

20 Austco Communications Systems PT Ltd.
All rights are reserved.

Austco Communications Systems PT Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any conse uences resulting from the use of this publication.

www.austco.com

CALLPOINTS
IP PULL CORDS

• Maintains reliability in harsh wet areas IP-CPG-PC/X | IP-CPG-PC/R/BS

• Flush anti-microbial soft-touch button for improved IP-CPG-PC/X
Infection control

• Interfaces to all standard Austco callpoint controllers

• Reassurance LED and beep

IP Pull Cord Callpoints

Water resistant, wall or ceiling mounted callpoints that initiate
calls on the Tacera Nurse Call System. The cord has a wipe-clean
surface and has its own strain relief to ensure reliable operation
without any possibility of damage. Standard features include a
reassurance LED, tone sounder for audibly or visually impaired
patients and call mute mode for cleaners.

Pull Cord Callpoints fit into standard electrical wall boxes, reducing
installation times and costs. Manufactured from an
impactresistant polycarbonate / ABS plastic, all Pull Cord
Callpoints feature concealed stainless steel fixings to maximize the
life of the callpoint and reduce maintenance costs.

Lower “Whole-of-Life” Costs IP-CPG-PC/R/BS

Pull Cord Callpoints are IPnet and feature plug-and-play
functionality. They are connected in series using only standard
CAT5/6 cable that also provides POIPnet (Power Over IPnet).

Each callpoint has a unique address and is supplied configured for
immediate use. Once connected, the callpoint is quickly and easily
assigned to a room using a browser, which simplifies the process
and reduces the cost of installation and commissioning.

The system continuously checks the functionality of each device
and immediately notifies maintenance staff if any problem is
detected. Pull Cord Callpoints are hot swappable, making
maintenance a breeze – simply replace a callpoint and use a
browser to quickly configure the new device.

The pull cord incorporates a weak-link break point as a safety
measure. The pull cord can support up to 2 kg (4.416 lbs) of
weight before it will break apart.

www.austco.com or call to speak to our experts about a CS-030, Rev. A

Wall or Ceiling Mount

Available as a wall mount unit with standard 1 meter PVC plastic cord or as a ceiling mount unit with standard 3
meter PVC plastic cord.
The cord has four options for the cord ends. Please see ordering options for details.

SPECIFICATIONS

Feature IP-CPG-PC Description IP-CPG-PC/R/BS Description
85mm (3.35 inches)
Height 110mm (4.3 inches) 85mm (3.35 inches)
Width 68mm (2.7 inches)
Standard Australian/New Zealand/North American Wall Box Standard British (note unit depth below)
Wall Box Size Equivalent to ClipsalTM 2000 series plate British Plate
Plate
35mm (1.4 inches)
Depth
Weight 100 grams (3.5 oz)
Mounting Method Screw on
Connectors
Modular to room controllers, Screw terminal to overbed lamp, Pin headers to CPS-IML & RLY-2 or 5
Cable
Temperature 6-core flat or round (CAT5) modular cable (AWG 26) to call point controller.
Humidity Range
0 – 50°C (32 – 122°F)
Pull Cord Break Apart Point 0…85% Non Condensing

Compliance 2 kg (4.416 lbs) or greater

• UL 1069 Hospital Signaling and Nurse Call Equipment.
• RCM Mark.
• CAN/CSA 22.1 No. 205, CISPR 22 and EN 50081-1, EN 50082-1, and IEC 1000-4 series Electrocompatibility.
• ENV 50204:1995 Radiated Electromagnetic Field from Digital Radio Telephones Immunity Test.
• CE Mark of European Conformity.
• 47 CFR, Part 15 Subpart B Class B
• EN 55032:2015 + AC:2016
• 47 CFR FCC Part 15 Subpart B Class A
• EN 55024:2010
• UL2560: 1st edition 2011, CSA-C22.2 No. 205
• EN 62368-1:2014

ORDERING INFORMATION

Product Code Description Order Options for CPG-2MLPC
IP-CPG-PC/* IP Callpoint Pull Cord, Red or Green Fly Lead Specify cord & tag /*:
/R - Red Emergency
IP-CPG-PC/R/BS IP Callpoint Pull Cord, Red Fly Lead, British Style /G - Green Nurse Call

Note: The IP-CPG-PC Pull Cord Call Points include water resistant gasket and single surround. Pull cords to be ordered separately.

Pull Cord Ordering Options Description

AM-CORD/1M/G Pull Cord 1M Green Icon
AM-CORD/1M/G-T Pull Cord 1M Green, Text
AM-CORD/1M/R Pull Cord 1M Red Icon
AM-CORD/1M/R-T Pull Cord 1M Red, Text
AM-CORD/3M/G Pull Cord 3M Green Icon
AM-CORD/3M/G-T Pull Cord 3M Green, Text
AM-CORD/3M/R Pull Cord 3M Red Icon
AM-CORD/3M/R-BAN Pull Cord 3M Red Round Bangle
AM-CORD/3M/R-T Pull Cord 3M Red, Text

© 2019 Austco Communications Systems PTY Ltd.
All rights are reserved.

Austco Communications Systems PTY Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Ultra high visibility with wide 1800 viewing angle OVER DOOR
LIGHTS
• Steady or flashing illumination
IP-ODL-4RGB | IP-ODL-3LED
• Reduce power consumption by 88% vs conventional
corridor lamps 4RGB OPTION
Can show up to 4 unique calls at a time
Over Door Lights
3LED OPTION
The Over Door Light is used to indicate active alarms / calls
using four segments. The colors and flash rates are uniquely Red, Green and Yellow Segments
programmable for each call priority, allowing any existing
Nurse Call protocols to be simulated. CS-031, Rev. B

The Over Door Lights have been engineered to operate
independently of the primary Nurse Call server ensuring failsafe
operation.

Lower “Whole-of-Life” Costs

The four segment Over Door Lights are IP-based and feature
plug-and-play functionality. Over Door Lights are connected in
series using standard CAT5/6 cable that also provides POIPnet
(Power Over IPnet).

Each light has a unique address and is supplied configured
for immediate use. Once connected, the light is quickly and
easily assigned to a room using a browser, which simplifies
the process and reduces the cost of installation and
commissioning.

Tacera continuously checks the functionality of each light
and will immediately notify maintenance staff if any
problem is detected. The Over Door Lights are hot-swappable,
making maintenance a breeze – simply replace a light and
then use a browser to quickly re-assign functionality to the
new light.

www.austco.com or call to speak to our experts about a

Easily Viewed from a Distance Optional Three LED Colored Segment

There is a RGB LED per segment that provides improved An optional three LED Over Door Light is available, with
reliability and increased brightness that ensures alerts are standard red, green and yellow colored segments. There are
easy to view from a distance of up to approximately 50 feet. two solid state LED’s per colored segment for added
reliability and brightness.
Easy to Program On-site
Optional RGB Colored Segments
For each call priority, the number of segments and flashing rate
of the Over Door Light can be programmed on-site using a Over Door Light with four segments are available, with each
browser. These parameters can be set as a specific standard for segment having the option to pick from nine available colors.
a ward, individual rooms or as a global standard for the site. Each segment can independently show a color or all
segments can show the same color.

SPECIFICATIONS

Feature Description

Height 115mm (4.53 inches)
Width 145mm (5.71 inches)
Depth
55mm (2.17 inches)
Weight
109 grams (3.88 oz)
Wall Box Size
Mounting Method Standard Australian/New Zealand/North American Wall Box
Housing Wall Box or Surface Mount (options)
Connectors Shatterproof, heat-resistant polycarbonate plastic dome
Cable 2 x RJ-45 IPnet ports
Color Options CAT5, CAT5E, CAT6 or CAT6E
Temperature 4RGB has the option to select out of nine available colors for each segment
Humidity Range 0 – 50°C (32 – 122°F)
0…85% Non Condensing
Compliance
IP-ODL-3LED IP-ODL-4RGB

• AS/NZS CISPR 22:2009 • AS/NZS CISPR22:2009
• EN 61000-3-2:1995, EN 61000-3-3:2003, EN • EN 55022:2010,
• EN 55024:2010
61000-4-2:1995, EN 61000-4-3:1995, EN 61000-4-4:1995, • EN 55032:2015 + AC:2016
EN 61000-4-5:1995, EN 61000-4-6:1996, EN • EN 62368-1:2014
61000-4-11:1994, EN 61000-6-1:2001 • EN 61000-3-2:2009, EN 61000-3-3:2008 EN 61000-6-1:2007
• 47 CFR, Part 15 Subpart B Class B • 47 CFR, Part 15 Subpart B Class A, ANSI C63.4-2009
• UL 1069: 7th edition 2007, CAN/CSA 22.2 No. 205 • UL 1069: 7th edition 2007, CAN/CSA 22.2 No. 205
• UL2560: 1st edition 2011 • UL2560: 1st edition 2011

ORDERING INFORMATION

Product Code Description Order Options
IP-ODL-3LED IP Over Door Light 3 LED N/A
N/A
IP-ODL-4RGB IP Over Door Light 4 RGB

© 2019 Austco Communications Systems PTY Ltd.
All rights are reserved.

Austco Communications Systems PTY Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

IPNet Router

• Control and power up to 30 callpoints, over doorROOM CONTROLLER
lights and zone sounders IPnet ROUTER
IP-CCT/UL

• Fail safe operation - operates independently of server

• Browser based configuration for on-site remote
configuration and diagnostics

• Standard CAT5/6 cabling

IPNet Router Ethernet IP-Net Input
Ports Ports Power
The IPnet Router is a sophisticated callpoint controller and acts as a Connector
router between your nurse call LAN and the callpoint LAN. The IPnet
Router has been engineered to operate independently of the primary CS-032, Rev. B
nurse call server, ensuring fail safe operation of callpoints, over door
lights and local buzzers.
The router can manage up to 32 IPnet devices, however, for
maintenance it is recommended to manage up to 30 devices and keep
two spare. The router provides Ethernet functionality with monitored
and fused power over Cat5/6 cable for all IPnet devices.

n-board status LEDs provide visual confirmation of a network
connectivity and normal operating current and voltage. Callpoint
priorities and the level of call (bed, toilet, staff assist, emergency, etc.)
can be independently programmed for each IPnet device or callpoint.
Power for the router is provided by a battery backed power supply
and the P IPnet (Power ver IPnet) circuits are both monitored and
managed for voltage and current.

IP Connecti it for rue Integration

The IPnet Router is quick to install and easy to commission. When
connected to the server, it is automatically assigned a unique address,
integrating the router into your facilities network infrastructure is
straigh orward and it is continuously monitored for connectivity.

op isticated Processing Priorit Management

The IPnet Router is an advanced call processor, supporting specialized
features above and beyond traditional nurse call systems. These
advanced features include;
• utomatic call upgrade. The automatic call upgrade

function will upgrade callpoints within the room, when a specific
callpoint is activated. For example; patient callpoints may be
upgraded to Staff Assist callpoints when Nurse Presence is activated.

www.austco.com or call to speak to our experts about a

www.austco.com

• Callpoint Upgrade. Callpoints may be configured to be upgraded Fault Monitoring
to another call type should the callpoint be pressed three times
in quick succession or if the callpoint is pressed and held for a IPnet devices are monitored for faults. IPnet router monitors itself for
specified duration. temperature and voltage out of range.

• Protected callpoints are isolated from function unless another Multinode
call point is activated within the room. For example; the
“Transport Required” callpoint may be disabled unless “Nurse IPNet routers work with each other to allow for cross sounding and
Presence” has been activated. over door lighting.

• Cleaning Mode. By pressing and holding the Cancel Button on a Reduced Cost of Installation and Commissioning
callpoint, the callpoint enters a cleaning mode which temporarily
disables the button functionality to permit cleaning. The IPnet Router is commissioned and managed using a standard
browser. Allowing on-site or remote programming via a PCs or a
• The Multi Cancel function enables a single cancel button to Tablet.
cancel any number of active callpoints. For example; once a
Nurse Presence button has been pressed in a multi bed The plug-and-play capability of Tacera ensures that when connected,
environment, all existing patient calls may be cancelled within each device is automatically identified for default configuration;
the room. simplifying the installation process and reducing the cost of
installation and commissioning.

Additionally, the IPnet Router enables audible tones to be
configured on-site, to match your existing Nurse Call system and
dynamically adjust the volume levels based on day or night
configuration.

Reduced Ongoing Maintenance

The system continuously checks the functionality of each device and immediately notifies staff if any problem is detected. IPnet devices are hot
swappable, making maintenance a breeze, simply replace a device and then use a browser to quickly configure the device. The browser also
provides access to an event log for use as a service tool for network testing.

SPECIFICATIONS

Feature Description

Height 55.88 mm (2.2")
Width 195.1 mm (7.68")
Depth 132.1 mm (5.2")
Weight
Mounting Method 26.45 oz (749.84 grams)
Wall Box Size Surface Mount Enclosure
Connectors N/A
Power - plug-in screw terminal, IPnet - 2 x RJ-45 socket, Ethernet - 2 x RJ-45 socket
Cable
Current Consumption Power - (15AWG), CAT5 or CAT6
Voltage Standby: 105mA, Maximum: 1.5A
Temperature 12 to 32V DC
Humidity Range 0 – 50°C (32-122˚F)
0…85% Non Condensing
Compliance • EN 55022:2010 + AC:2011
• EN 55024:2010
• EN 62368-1:2014
• EN 61000-3-2:2014, EN 61000-3-3:2013
• 47 CFR, Part 15 Subpart B Class A
• UL 1069: 7th edition 2007, CAN/CSA 22.2 No. 205
• UL 2560: 1st edition 2011

ORDERING INFORMATION

Product Code Description Order Options
IP-CCT/UL IPnet Router/UL, 30 Devices N/A

© 2019 Austco Communications Systems PTY Ltd.
All rights are reserved.
Austco Communications Systems PTY Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

4 BUTTON CALLPOINT
IP-CPS-4B

• Streamline workflow by alerting designated staff to
an active workflow

• Notification of rounding reminders via pagers, wireless
telephones, overdoor lights and LED displays

• User configurable buttons for Sequential, Independent
or Concurrent operation

on Callpoints Bright LED reassurance

A flush wall mounted callpoint that is used for both Nurse Call and
Workflow applications. The four touch buttons can be individually
programmed for any Nurse Call, Status or Workflow function. Each
button has a user inscribable tag that indicates its function and is
placed behind a clear lexan cover for improved infection control.

To initiate a single workflow event or a sequence the staff member
presses the appropriate button. The alert is automatically sent to
pagers and wireless telephones.

Hundreds of workflow events are available. A workflow event
can be a single on/off event or up to four workflow buttons can
be sequenced together, so that pressing the next button in the
sequence automatically cancels the previous event.

The 4 Button Callpoint fits into standard electrical wall boxes,
reducing installation times and costs. Manufactured from an
impact-resistant plastic, the callpoint features concealed fixings to
maximize the life of the callpoint and reduce maintenance costs.

o er ole of ife Costs User configurable buttons
Programmable to any sequence
The 4 Button Callpoint is IP-based and features plug-and-play
functionality. The callpoint is connected in series using only
standard CAT5/6 cable that operates from P IPnet (Power ver
IPnet).

Each callpoint has a unique address and once connected, the
callpoint is quickly and easily assigned functionality in a room using
a browser, which simplifies the installation process and reduces the
cost of installation and commissioning.

www.austco.com CS-033, Rev. C

The system continuously checks the functionality of The 4 Button Callpoint supports multiple scenarios, and
each callpoint and will immediately notify staff if any the activation and cancellation of calls is configurable
problem is detected. The callpoint is hot-swappable, for each scenario.
making maintenance a breeze – simply replace a
callpoint and then use a browser to quickly re-assign The callpoint is connected on the IPnet patient area
functionality to the new device. network to all other components of the Tacera system
to initiate communication between staff.

Easy to Identify and Use Improved Infection Control

This callpoint features four configurable buttons plus a This ergonomic callpoint is flush, wall mounted and
CANCEL button, all clearly labelled for easy and fast includes a clear plastic lexan that covers the buttons for
identification. A colored LED above each button will improved infection control.
illuminate when a call is active, and users can easily
cancel an active call with a simple button press.

SPECIFICATIONS

Feature Description

Height 116.1 mm (4.57")
Width 75.9 mm (2.99")
Depth 22.01 mm (0.87")
Weight 75.13 grams (2.65oz)
Mounting Method Screw on
Plate Austco Modular Plate
Wall Box Size Standard North American size wall box
Housing Wall Box

Connectors IPnet: 2RJ45
CAT5 or CAT6
Cable 0 – 50°C (32 – 122°F)
Temperature 0…85% Non Condensing
Humidity Range
• AS/NZS CISPR22:2009
Compliance • EN 55022:2010
• EN 55024:2010
• EN 61000-6-1:2007, EN 61000-3-2:2009, EN 61000-3-3:2008,
• EN 61000-4-2:1995, 61000-4-3:1995, EN 61000-4-4:1995, EN 61000-4-5:1995,
• EN 61000-4-6:1996, EN 61000-4-11:1994, EN 61000-6-1:2001
• EN 62368-1:2014
• 47 CFR, Part 15 Subpart B Class A and B
• UL 1069: 7th edition 2007, CAN/CSA 22.1 No. 205
• UL2560: 1st edition 2011, CSA-C22.2 No. 205
• CE Compliant
• HTM 08-03

ORDERING INFORMATION

Product Code Description Order Options
IP-CPS-4B IP Callpoint, 4 Button N/A

© 2019 Austco Communications Systems PTY Ltd.
All rights are reserved.

AoAobubulslisitgtgcacaototiiCoCoononmmaanmnmdduuwnwniiicilcllalantntioioootntnbsbseeSSylyliisasatbtbeelmlemefsfsooPrPrTTaaYYnnLyLyttcdcdo.o.nrnreseseseseqeqruruvveeeensnscctethehseserrrereisigsguhuhltltttitintnooggttfafrarkokoememcchththahaenenguguesesseseioinonffsstpthpheieiscscipifipfiucucbabatltliiiciocoananttsisiooaannnn..dd//oorrddiissccoonnttiinnuueeaannyypprroodduuccttaattaannyyttiimmeewwiitthhoouuttnnoottiicceeoorr
www.austco.com

• C ENTERTAINMENT
•C HANDSET
•C
IP-CAA-EEH

C
Entertainment Handset

C

Clear, Two-way Audio
Communication

C

C C
C

a o nti an an

i Con o
C
ountin tion

Con o

SPECIFICATIONS

Feature c i tion C
Height 180mm (7.1" C
Width 61mm (2.4"
30mm (1.18"
Weight
C
Housing
Connectors C
C C

CC C

C C
C
CC
C

ORDERING INFORMATION

Product Code c i tion Or tion
IP-CAA-EEH/x Ergonomic Entertainment Handset

C
All rights are reserved.

C

www.austco.com

APPLICATION STATION
IP-APP1

(Hardware Only)

• Ultra clear, stylish and sleek appearance

• High-resolution back-lit LCD with a bright, high-contrast display Tacera
• Two-way voice communication

• Tamper-resistant design

us co s pp ic tion tion

The Application Station is a sleek touch screen that provides a
clear display of active calls and rounding reminders. The
Application Station also supports custom workflow features
including patient transport, room cleaning and many other
user-defined events.
A high-resolution back-lit LCD with a bright, high-contrast
display is easy to read and simple to configure using the
Application Station Configuration tool.

The Application Station provides caregivers with the added
confidence that they are providing patients with high-quality
care by initiating rounding, wound care and pain assessment via
the intuitive user interface. Patient satisfaction is increased as
patients are assured their needs are taken care of at scheduled
intervals throughout the day.

urse tion in er Roo

The Application Station is like having a urse Station in every
room. Care providers can easily view a list of active calls for
the defined display location, to gain a holistic view of the unit.
Call type priorities are color-coded, allowing highest-priority
calls to be easily identified. The level of priority, location, type
and duration of each call is displayed and is accompanied by
distinctive alert tones for each priority of call.

Voice call functionality allows calls between the Application
Station and any intercom or nurse station on the system to be
easily initiated or answered. It also adds shortcut one-bu on
dialing and hands-free tap-to-call operation.

www.austco.com or call to speak to our experts about a CS-035, Rev. B

Licenses Rounding

• By acquiring the IPC-DUTY license with the Application Station, a The Application Station assists caregivers in supporting the
healthcare facility benefits by having increased clinical workflow evidence-based practice of rounding by reminding them when it’s
features, enabling nurses to manage their day-to-day tasks such time to check in on patients. Rounding provides more than a boost to
as rounding. patient satisfaction, it also:

• An optional IPC-AUDIO license shall be acquired if using the • reduces the number of patient falls
Application Station as an intercom device. • improves the unit’s workflow by reducing the number of calls
• increases interaction between caregivers and patients

SPECIFICATIONS

Feature Description

Height 182.5 mm (7.18 in)
Width 251 mm (9.88 in)
Depth 22 mm (0.86 in)
Weight 969 g (34.2 oz)
Mounting Method Supports USA and European electrical wallbox mounting
Display Projected Capacitive Touch Screen
Display Resolution 1280 x 800 (16:9) Pixel
Display Size 10" (Diagonal)

Power Within IEEE 802.3af PoE standard of 15.4 W
Power Input PoE IEEE 802.3af
VoIP SIP

Speaker Built-in

Microphone Built-in

Ethernet 1 x Ethernet PoE (802.3af) and 1 x switched Ethernet (non-powered)
Temperature 14° to 112°F (-10° to 45°C)

Humidity Range 10% to 90% (non-condensing)
Compliance • EN 55032:2015
• EN 55035:2017
• EN 60950-1
• EN 61000-3-2:2014
• EN 61000-3-3:2013
• FCC PART 15B

ORDERING INFORMATION

Product Code Description Order Options
IP-APP1 Wall Mounted Touch Screen Application Station N/A
IPC-DUTY License for Application Station Software N/A
IPC-AUDIO License for VoIP Audio enabled communications (Optional) N/A

IP-APP1-ADPT Required to mount IP-APP1 using IP-Duty Back Box N/A

© 2019 Austco Communication Systems PTY Ltd.
All rights are reserved.
Austco Communication Systems PTY Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

DEMENTIA CARE
SYSTEM CONTROLLER

• Non-intrusive Automated Controller IP-DCS-2000
• User Friendly Two Button Operation
• Exception Alarm Reporting (Hardware Only)
• Light Queuing
• Operational Button Security Delay

Dementia Care System Controller

The Dementia Care System Controller is a stand-alone controller
that integrates with various movement sensors to provide a
system for the non-intrusive monitoring and care of residents
suffering from confusion as result of Alzheimer’s or other
Dementia disorders. The level of monitoring is selectable from
16 researched pre-defined behaviour profiles.

Integrated with an Austco Nurse Call System, the Dementia
Care System Controller provides a total specialised care system
including integration with logging to analyse a resident’s
movements by display, sorting, reporting and/or exporting to
other applications.

Easy to Install

The Dementia Care System Controller is a standard size flush
wall mountable panel, typically installed immediately outside
the resident’s room, and contains an On/Off button, Select
Profile button and a 7-segment Status Display.

The Dementia Care System Controller works with 2G and 3G
Products. It has a 3 way jumper link provided for 2G, the link
should be put in the 12V side and for 3G the other side is 24V.
The 12 volts out is provided capable of feeding 100mA for PIR
operation.

Easy to Identify and Use

The Dementia Care System Controller is a small, easy to use,
two button operated controller that alerts staff if a resident is in
need of care. There is no computer, keyboard or complex
programming required from staff.

www.austco.com or call to speak to our experts about a CS-036, Rev. B

The Dementia Care System Controller’s ability to Night Mode
establish a resident’s typical behavioural pattern allows
staff to anticipate times when the resident may display Typically the system is switched on at night to monitor
non-typical behaviour preventing falls, stitches or inputs from a bed exit sensor plus other movement
other emergency medical care . The system sensors such as PIRs and reed switches located within
automatically advises staff of a resident’s change in the resident’s room. The bed exit sensor is the master
behavioural patterns. Staff are able to be pro-active in input that signals when the resident leaves the bed,
providing care, without the resident feeling like being a er which the Dementia Care System Controller
under constant supervision. monitors the resident’s activity through inputs from

t Controls the other movement detectors. If the resident’s activity
varies from the selected profile, an alarm is raised and
Automatic light queuing is included that pre-empts a sent to the Nurse Call System, identifying the room
resident’s movements when the bed exit signal is number for normal Nurse Call System alarm/call alert
detected and switches room and/or ensuite lights on or handling such as display, logging, printing and paging.
off as a prompt to assist the resident to follow the
lights.

SPECIFICATIONS

Feature Des r tion

eight 110 mm 4.33
idth 6 mm 2.67
Depth 30 mm 1.1
eight
ounting ethod 100 grams 3. 2oz
Plate Screw on
all Box Size Austco odular Plate
ousing Standard North American size wall box

Connectors all Box

Cable Screw Terminals
Temperature CAT or CAT6
0 0 C 32 122 F
umidity Range 0 Non Condensing

Compliance T 0 -03 Bedhead services.

EN 022 2010, AS/N S CISPR22 200 , EN 61000-6-1 2007, EN 61000-3-2 200 , EN 61000-3-3 200

47 CFR, Part 1 Subpart B Class A

ORDERING INFORMATION

Product Code Des r tion Order tions
IP-DCS-2000/* N/A
Dementia Care System Controller Full Dementia onitoring System
12VDC for 2G and 24VDC for 3G
*Note: Bed Exit Pad is required and must be purchased separately as non Austco supplied product.

201 Austco Communications Systems PT td.
All rights are reserved.

AooAbubulslisitgtgcacaototiiCoCoononmmaanmnmdduuwnwniiicilcllalantntioioootntnbsbseeSSylyliisasatbtbeelmlemefsfsooPrPrTTaannyyttcdcdo.o.nrnreseseseseqeqruruvveeeensnscctethehseserrrereisigsguhuhltltttitintnooggtmfafrrkoaoemkmechttchahheneagunuesgsseeeisonofifnstpthshepiiscseipficpuicufibabctlaliiicoctainaottsiniooasnnna..dn/do/rodridscisocnotnintiuneueanaynyprpordoudcutcattaatnaynytimtime ewwithitohuotuntontoictieceoror
www.austco.com

INPUT BRIDGE ISOLATED
IP-OPT8

• Integrates third party clinical systems with Tacera Tacera
• Over door lights and audible chimes may be activated from

the input bridge
• Alarm details may be relayed to pagers, wireless telephones,

bridges and LCD annunciators
• Easy to install with CAT5/6 cable

IP Input Bridge Isolated Allows both messaging and relay
output events to be actioned
The IP Input Bridge Isolated enables up to eight external
devices such as patient monitors, ventilators, IV pumps, pulse More than one input can trigger a
oximeters, room sensors, access control sensors and alarms to common event or output
be interfaced into Tacera.

An integral buzzer sounds when the bridge is first connected
to an IPnet Router, giving the installer reassurance that the
device has been connected and is functioning.

Lower “Whole-of-Life” Costs

The IP Input Bridge Isolated is IP-based and features plug-and-
play functionality. Bridges are connected in series using only
standard CAT5/6 cable that also provides POIPnet (Power Over
IPnet).

Each bridge has a unique address that is used to identify
the device on the IPnet Router. Once connected, the device
is assigned an IPnet address then each input is quickly and
easily assigned to a room or area and function using a browser.
This simplifies the installation process and reduces the cost of
installation and commissioning.

The system continuously checks the functionality of each
bridge and immediately notifies staff if any problem is
detected. Bridges are hot swappable, making maintenance a
breeze – simply replace a bridge and then use a browser to
configure the device.

www.austco.com or call to speak to our experts about a CS-038, Rev. B

Individual Control Safe and Reliable

There are eight independent 6-24V AC or DC opto isolated inputs The electrical isolation between the bridge inputs and the IPnet
that can be individually set as normally open (NO) or normally closed ports maintains compliance with IEC 60601-1 Medical electrical
(NC) using a browser. equipment - Part 1: General requirements for basic safety and
essential performance.
To ensure reliability, the bridge has been designed and manufactured
for immunity against voltage spikes and static charges, the most
common causes of electronic failure.

SPECIFICATIONS

Feature Description
Height
Width 66.04 mm (2.6 in)
Depth 133.60 mm (5.26 in) including mounting planges
Weight 36.06 mm (1.42 in)
Mounting Method 109.99 g (3.88 oz)
Connectors Surface mount. 2 holes 4.8" centres
IPnet - 2 x RJ-45 socket
Cable Inputs - 16 screw terminals for 8 isolated inputs
CAT5 or CAT6
Temperature Inputs - 2 core (AWG 18-24) security cable for each call input
Humidity Range
Compliance 0° - 50°C (32° - 122°F)

0...85% Non Condensing)
• 47 CFR, Part 15 Subpart B Class B
• UL 1069: 7th edition 2007
• UL2560: 1st edition 2011
• CAN/CSA 22.2 No. 205
• AS/NZS CISPR 22:2009, EN 6100-6-1:2001, EN 61000-3-2:1995, EN 61000-3-3:2003, EN 61000-4-2:1995,

EN 61000-4-3:1995, EN 61000-4-4:1995, EN 61000-4-5:1995, EN 61000-4-6:1996, EN 61000-4-11:1994
• EN 62368-1:2014
• HTM 08-03

ORDERING INFORMATION

Product Code Description Order Options
IP-OPT8 IP 8 Input Bridge Optically Isolated N/A

© 2019 Austco Communication Systems PTY Ltd.
All rights are reserved.
Austco Communication Systems PTY Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Integrates third party clinical systems with Tacera INPUT BRIDGE
IP-IN8
• Over door lights and audible chimes may be activated from Tacera
the input bridge Allows both messaging and relay
output events to be actioned
• Alarm details may be relayed to pagers, wireless telephones,
bridges and LCD annunciators More than one input can trigger a
common event or output
• Easy to install with CAT5/6 cable

IP Input Bridge

The IP Input Bridge enables up to eight external devices such
as patient monitors, ventilators, IV pumps, pulse oximeters,
room sensors, access control sensors and alarms to be
interfaced into Tacera.

An integral buzzer sounds when the bridge is first connected
to an IPnet Router, giving the installer reassurance that the
device has been connected and is functioning.

Lower “Whole-of-Life” Costs

The IP Input Bridge is IP-based and features plug-and-play
functionality. Bridges are connected in series using only
standard CAT5/6 cable that also provides POIPnet (Power Over
IPnet).

Each bridge has a unique address that is used to identify
the device on the IPnet Router. Once connected, the device
is assigned an IPnet address then each input is quickly and
easily assigned to a room or area and function using a browser.
This simplifies the installation process and reduces the cost of
installation and commissioning.

The system continuously checks the functionality of each
bridge and immediately notifies staff if any problem is
detected. Bridges are hot swappable, making maintenance a
breeze – simply replace a bridge and then use a browser to
configure the device.

www.austco.com or call to speak to our experts about a CS-039, Rev. B

Individual Control Safe and Reliable

There are eight independent, voltage free inputs that To ensure reliability, the bridge has been designed
can be individually set as normally open (NO) or and manufactured for immunity against voltage
normally closed (NC) using a browser. spikes and static charges, the most common causes
of electronic failure.

SPECIFICATIONS

Feature Description
Height
Width 66.04 mm (2.6 in)
Depth 134.11 mm (5.28 in) including mounts
Weight 36.06 mm (1.42 in)
Housing 109.99 g (3.88 oz)
Mounting Method Plastic enclosure
Connectors Surface mount. 2 holes 4.8" centres
IPnet - 2 x RJ-45 socket
Cable Inputs - 16 screw terminals for 8 inputs
CAT5 or CAT6
Temperature Inputs - 2 core (AWG 18-24) security cable for each call input
Humidity Range
Compliance 0° - 50°C (32° - 122°F)

0...85% Non Condensing)
• EN 55022:2010, AS/NZS CISPR22:2009, EN 61000-6-1:2007, EN 61000-3-2:2009, EN 61000-3-3:2008
• 47 CFR, Part 15 Subpart B Class A, ANSI C63.4-2009
• AS/NZS CISPR 22:2009, EN 6100-6-1:2001, EN 61000-3-2:1995, EN 61000-3-3:2003, EN 61000-4-2:1995,

EN 61000-4-3:1995, EN 61000-4-4:1995, EN 61000-4-5:1995, EN 61000-4-6:1996, EN 61000-4-11:1994
• 47 CFR, Part 15 Subpart B Class B
• HTM 08-03

ORDERING INFORMATION

Product Code Description Order Options
IP-IN8 IP 8 Input Bridge N/A

© 2019 Austco Communication Systems PTY Ltd.
All rights are reserved.
Austco Communication Systems PTY Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Provides two individually controlled relays IP DUAL RELAY
IP-RLY
• Electrically isolated for high voltage (Hardware Only)

• Patient may use hand held pendant for lighting and
blind control

• Easy silent installation with buzzer sounding when
device has been successfully connected

IP Dual Relay

The IP Dual Relay allows patients to control lighting and
blinds from the comfort of their bed using any of Austco’s
entertainment handsets or pendants. For maximum flexibility,
the Dual Relay can be used to switch any connected device
from any callpoint on the system.

An integrated buzzer sounds when the Dual Relay is connected
to an IPnet Router, giving the installer reassurance that the
device has been detected and is functioning. Change over
contacts allow each relay contact to be wired in a two-way
lighting circuit.

Connects to the
IPnet Router

Lower “Whole-of-Life” Costs

The IP Dual Relay is IP-based with plug-and-play functionality. Dual Relays are typically installed in the patient’s room
and connected in series using only standard CAT5/6 cable that also provides POIPnet (Power Over IPnet).

Each Dual Relay has a unique address that is used to identify the device on the IPnet Router. Once connected, the device
is quickly and easily assigned to an input or lighting control on a patient handset using a browser, which simplifies the
process and reduces the cost of installation and commissioning.

The system continuously checks the functionality of each Dual Relay and immediately notifies maintenance staff if any
problem is detected. Dual Relays are hot swappable, making maintenance a breeze – simply replace a Dual Relay and
then use a browser to configure the device.

www.austco.com or call to speak to our experts about a CS-040, Rev. B

Individual Control Safe and Reliable

There are two sets of relay contacts that are The Dual Relay has been designed and manufactured
individually controlled from callpoint or pendant to meet stringent international electrical isolation
bu ons via the router. The relays are designed for standards. The Dual Relay enclosure includes two
inductive or resistive AC loads up to 5 volts at cable-clamp glands while the mains connectors are
amps. internal to allow safe termination of the lighting cables.

Additionally, the relay outputs may be programmed for The electronic design allows POIPnet, removing the
either continuous operation such as opening and need for a separate power supply normally associated
closing blinds or for toggle based operations such as with a mechanical pulse relay. As a result, the Dual
turning lights on and off. Relay is both reliable and quiet.

SPECIFICATIONS

Feature Description
Height
95mm (3.74 inches)
idth 135mm (5.31 inches)
Depth
Weight 36mm (1.41 inches)
130 grams (4.58 oz)
ounting ethod urface ount
Housing Plastic
Connectors
IPnet - x R - 5 socket
Cable Relay - 2 x 3 way screw terminal
Current Consumption
CAT5 or CAT6
oltage
Temperature tandby 5mA at
aximum mA at
umidity Range IPnet powered,
Compliance 0 – 50°C (32 – 122°F)

5 on Condensing

• CFR, Part 5 ubpart Class

• 6 th edition

• 56 st edition

• CA /C A . o. 5

• A / CI PR , E 6 -6- ,E 6 - - 5, E 6 - - ,E 6 -- 5, E 6 - - 5,
E 6 -- 5, E 6 - -5 5, E 6 - -6 6, and E 6 - -

•E 6 6 -

• CE Compliant

•T -

ORDERING INFORMATION

Product Code Description Order Options
IP-RLY IP Dual Relay N/A

Austco Communications ystems PT td.
All rights are reserved.

Austco Communications ystems PT td. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Simplified cabling from room to room T JUNCTION
• Regenerate signals IP-TJ
• Requires no external power supplies (Hardware Only)

IPnet Cabling CS-041, Rev. B

Tacera callpoints are efficiently cabled using Cat5/6 cable in a
daisy chain fashion throughout the room and ensuite. Room
Controllers can be used for multiple rooms making for cost
effective deployment.
The T-Junction allows a common Cat5/6 cable down the
corridor and branch to each room along the corridor. This
branch and continued cabling provides for a simple way to
deploy and maintain cabling arrangement.

Connections

The T-Junction interfaces to the IP-CCT via a Cat5/6 UTP cable
with 8-way modular connectors. Three IPnet ports allow both
power and IPnet data to pass through the devices. There are
two types of connectors in the IP-TJ:
• Main IPnet Connector - connected to a Room Controller or

another IP-TJ on the main IPnet bus
• Branch IPnet Connector - connected to IPnet devices.
Connect a cable to one of its RJ45 connectors and then to one
of the IPnet connectors on the Room Controller.

Installation

The T-Junction is contained in a small sealed plastic enclosure
that can be fitted in the roof space outside of the rooms. In
addition, the T-Junction is line powered and therefore
requires no external power supplies.

www.austco.com or call to speak to our experts about a

CAUTION
hen using IP-PST , do not use IP-TJ or

IP-IJ on an IPnet port. ue to the total
power consumption limitation of Po a
so start power turn on of the IPnet bus
can put the IP-TJ/IP-IJ into an unstable
state, which causes IP- -4R B to not
respond to IPnet commands.

SPECIFICATIONS

Feature esc tion

Height 30mm (1.18 inches)
idth 82mm (3.23 inches)

epth 54mm (2.13 inches)
Weight 145 grams (5.11 oz)
Mounting Method Surface Mount
Housing Black Plastic Case
Connectors
x RJ45 modular 8P8C
IPnet
Main IPnet Consisting of 8 circuits, 4 power and data communication
Branch IPnet Pass through of IPnet
Power
ata signals regenerated on the branch
Temperature 0. 5 ine powered from IPnet
umidity Range
0 – 50°C (32 – 122°F)
Compliance 0 85 on Condensing

• 4 C R, Part 15 Subpart B Class and B 61000-4- :1 5, 61000-4-4:1 5,
• S/ S CISPR : 00 , 61000- - :1 5, 61000- - : 00 , 61000-4- :1 5,

61000-4-5:1 5, 61000-4-6:1 6, 61000-4-11:1 4, 61000-6-1: 001
• 550 4: 010
• 550 : 015 C: 016
• HTM 08-03

ORDERING INFORMATION

Product Code esc tion Or e tions
IP-TJ IPnet Device, Branches IPnet Bus N/A

01 ustco Communications Systems PT td.
ll rights are reserved.

ustco Communications Systems PT td. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

RF PENDANT
IP-CPG/RF
(Hardware Only)

• Hard-wearing and washable
• Anti-bacterial protection with infection control
• Supports multiple wireless wearable pendants
• “Three Button Press” for emergency calls

IP Callpoint Lower ‘Whole-of-Life’ Costs

With all of the benefits and features of regular callpoint, IP Generic Callpoints are IPnet and feature
the addition of wireless wearable pendant enables the auto-discover functionality. They are connected in
patient to move around with the comfort that they can series using standard Cat5/6 cable that also provides
raise a call any time anywhere. Multiple pendants can be POIPnet (Power Over IPnet).
registered to the one callpoint offering great flexibility in
common areas. Additionally, each callpoint has a unique address and
is supplied configured for immediate use. Once
Large and easy to activate, the Austco call button provides connected, the callpoint is quickly and easily
a positive tactile response when pressed. This makes it assigned to a room using a browser, simplifying the
ideal for patient/residents with restricted or limited installation process and reducing the cost of
movement. installation and commissioning.

Standard features include backlit buttons for night viewing The system also continuously checks the
by residents and patients, a reassurance LED and tone functionality of each callpoint and will immediately
sounder for audibly or visually impaired patients, and call notify staff if any problem is detected. Callpoints are
mute mode for cleaners. hot-swappable, making maintenance a breeze,
simply replace a callpoint and then use a browser to
Callpoints are designed with changeable inserts, as shown quickly configure the device.
in picture.
Wearable pendant Generic Callpoint with
The call button design enables a facility to swap out and transmitter RF receiver
replace the current insert instead of having to replace the
entire callpoint. For example, a facility can change a Staff
Assist Callpoint in a room to an Emergency Callpoint by
simply swapping out the Staff Assist button insert for an
Emergency Call button insert and reprogramming the
system. This low maintenance feature adds flexibility and
efficiency, thus increasing patient care, as a facility can
change the alerts after the initial installation.

www.austco.com or call to speak to our experts about a Changeable inserts
(ordered separately)

CS-042, Rev. B

Easy to Identify and Use the callpoint enters a cleaning mode which temporarily
disables the button functionality to permit cleaning.
IP Generic Callpoints feature soft-touch push buttons
that are clearly labelled with text or icons for easy and Improved Infection Control
fast identification. The call button insert is available in a
number of standard colors and icons, allowing the The silicone surround is manufactured with an antibacterial
system to operate a variety of alarm levels and system additive for improved infection control.
inputs as determined by the protocols of the facility.
Over Bed Indicator
The callpoint can be configured to allow active calls to
be upgraded to a higher level by pressing the call An over bed indicator can be added to display the call status.
button three times or holding it for three seconds. This
feature can eliminate the need for separate staff assist RF Pendants
buttons thus further reducing infrastructure costs.
Single or multiple pendants are supported by a callpoint.
To avoid nuisance alarms during cleaning, the callpoint False alarms are avoidable in single-pendant environment
provides a cleaning mode. By pressing and holding the as they only occur on the callpoint to which the pendant is
Cancel Button on a callpoint for a specified duration, paired. Pendants can be paired to multiple callpoints
offering great flexibility in supporting a patient in both their
SPECIFICATIONS room and in common areas.

Feature Description

Height 116mm (4.57 inches)
Width 76mm (2.99 inches)
Depth 26mm (1.02 inches)
Weight 100 grams (3.5 oz)
Mounting Method Screw on
Plate Austco modular plate
Wall Box Size Standard single Wall Box
Connectors IPnet: 2 x RJ45 socket Over bed indicator: 2 mm screw terminal (AWG 24)
Cable Cat5 or Cat6 (AWG 24) Data / Security cable to over bed indicator light

Receiver Frequency 304 MHz
Paired Pendants 355

Receiver Range 50 m (164 ft)
Temperature
Humidity Range 0 – 50°C (32 – 122°F)
Compliance 0…85% Non Condensing

• 47 CFR, Part 15 Subpart B Class B
• UL 1069: 7th edition 2007
• UL2560: 1st edition 2011
• CAN/CSA 22.2 No. 205
• AS/NZS CISPR 22:2009, EN 6100-6-1:2001, EN 61000-3-2:1995, EN 61000-3-3:2003, EN 61000-4-2:1995, EN 61000-4-3:1995,

EN 61000-4-4:1995, EN 61000-4-5:1995, EN 61000-4-6:1996, EN 61000-4-11:1994
• EN 62368-1:2014
• CE Compliant
• HTM 08-03

ORDERING INFORMATION Order Options
Product Code Description *Inserts are ordered separately

IP-CPG/RF IP CallPoint with RF Transmitter

Accessory: AM-RFPD/W - RF Pendant Transmitter 304 MHz which is ordered separately

© 2019 Austco Communications Systems PTY Ltd.
All rights are reserved.

Austco Communications Systems PTY Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

RACK MOUNT IPNET
ROUTER
IP-CCT/H
• Control and power up to 30 callpoints, over door
lights and zone sounders (Hardware Only)

• Fail safe operation - operates independently of server
• Browser based configuration for on-site remote

configuration and diagnostics

• Suitable for structured cabling installations

Rack Mount IPnet Router Industry standard 19” Rack
Mount 3RU
The Rack Mount IPnet Router is a highly sophisticated callpoint
concentrator and acts as a router between your Nurse Call LAN
and the callpoint LAN. The IPnet Router has been engineered to
operate independently of the primary Nurse Call server, ensuring
fail safe operation of callpoints, over door lights and local buzzers.

Callpoint priorities and the level of call (bed, toilet, staff assist, IP-HUB
emergency, etc.) can be independently programmed for each IPnet
device or callpoint. Each router card can be accessed locally or Support for ten IPnet Routers
remotely, providing added exibility and maintenance options. per Rack

IP Connecti it for rue Integration

When connected to the server, it is automatically assigned
an unique IP address if DHCP is enabled, making integration
of the router into your facilities network infrastructure
straigh orward and can be continuously monitored for
connectivity.

op isticated Processing IP-CCT/H
Priorit Management

The IPnet Router is an advanced call processor, supporting Each router card provides IP-CCT/Blank
specialized features above and beyond traditional Nurse Call control and power up to 30 Optional blank plate
systems. These advanced features include:
• Automatic callpoint upgrade. The automatic callpoint upgrade IPnet devices

function will upgrade callpoints within the room, when a specific
callpoint is activated. For example; normal patient callpoints may
be upgraded to Staff Assist callpoints once Nurse Presence is
activated.

• Callpoint Upgrade. Callpoints may be configured to be upgraded
to another call type should the callpoint be pressed three times
in quick succession or if the callpoint is pressed and held for a
specified duration.
or call to speak to our experts about a
www.austco.com CS-043, Rev. B

• Protected callpoints are isolated from function The plug-and-play capability of Tacera ensures that when
unless another call point is activated within the connected, each device is automatically identified for default
room. For example; the “Transport Required” configuration; simplifying the installation process and reducing
callpoint may be disabled unless “Nurse Presence” the cost of installation and commissioning.
has been activated.
Reduced Ongoing Maintenance
• Cleaning Mode. By pressing and holding the Cancel
Button on a callpoint, the callpoint enters a cleaning The system continuously checks the functionality of each
mode which temporarily disables the button device and immediately notifies staff if any problem is
functionality to permit cleaning. detected. IPnet devices are hot swappable, making
maintenance a breeze, simply replace a device and then use a
• The Multi Cancel function enables a single cancel browser to quickly configure the device. The browser also
button to cancel any number of active callpoints. For provides provides access to an event log for use as a service
example; once a Nurse Presence button has been tool for network testing.
pressed in a multi bed environment, all existing
patient calls may be cancelled within the room. POIPnet and Power Monitoring

Reduced Cost of Installation Power for the router is provided by a battery backed power
and Commissioning supply and the POIPnet (Power Over IPnet) circuits are both
monitored and managed for voltage and current.
The IPnet Router is commissioned and managed using
a standard browser. Allowing on-site or remote IP-HUB
programming via a PC or a Tablet.
IP-HUB can support ten rack mount IPnet routers. It has simple
SPECIFICATIONS and automated functionality, and takes up 3RUs, allowing it to be
installed in a server rack in a communications room.

Feature Description

Height 132mm (5.2 inches)
Width
Depth 485mm (19 inches)
Weight 160mm (6.3 inches)
Mounting Method 4517.78 grams, 159.3 oz, 9.96 lbs
Current Consumption 19" rack-mount enclosure
for each router card
Standby: 255mA
Voltage Maximum: 1.5A
Connectors
Cable 18-28V DC
Temperature Power - plug-in screw terminal, IPnet - 2 x RJ-45 socket, Ethernet - 2 x RJ-45 socket
Humidity Range
Compliance Power - 2 core (15AWG) 1.5mm2 CAT5 or CAT6

0 – 50°C (32 – 122°F)
0…85% Non Condensing
• 47 CFR, Part 15 Subpart B Class A, ANSI C63.4-2009
• UL 1069: 7th edition 2007
• UL2560: 1st edition 2011
• CAN/CSA 22.2 No. 205
• EN 55022:2010, AS/NZS CISPR22:2009, EN 61000-6-1:2007, EN 61000-3-2:2009, EN 61000-3-3:2008
• EN 62368-1:2014
• CE Compliant
• HTM 08-03

ORDERING INFORMATION

Product Code Description Order Options
IP-CCT/H Rack Mount IPnet Router Card and Holder, 30 Devices The IP-HUB is not sold with any Router Cards or
Blank Plates - these must be ordered separately
IP-CCT/BLANK Rack Mount IPnet Router Enclosure Blank Plate

Accessory: IP-HUB Rack Mount IPnet Router Enclosure, 10 slots

© 2019 Austco Communications Systems PTY Ltd.
All rights are reserved.

Austco Communications Systems PTY Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Adjustable volume level depending upon time of day ZONE TONE
SOUNDER
• Unique audio tones identify call type
• Selectable sets of alert tone sound sequences that IP-ZTS/O
IP-ZTS/O/BS
replicate the Annunciator
Selectable set of alert tones
• Easy to install with CAT5/6 cable
IP-ZTS/O
Zone Tone Sounder Selectable set of alert tones

A wall or ceiling mounted speaker that is used to audibly IP-ZTS/O/BS
annunciate active calls in an area on the Tacera Nurse Call
System. It is typically used in conjunction with an audio / CS-044, Rev. B
visual Annunciator, and located in areas where the Annunciator
cannot be seen or heard.

The Zone Tone Sounder fits into standard electrical wall boxes,
reducing installation times and costs.

Manufactured from an impact resistant polycarbonate / ABS
plastic blend, the sounder features concealed fixings to
maximize the life of the sounder and reduce maintenance
costs.

Lower “Whole-of-Life” Costs

The Zone Tone Sounder is IP-based and features plug-andplay
functionality. It is connected in series using only standard
CAT5/6 cable that also provides POIPnet (Power Over IPnet).
Each sounder has a unique address and is supplied configured
for immediate use. Once connected, the sounder is quickly
and easily assigned to a zone / area using a browser, which
simplifies the process and reduces the cost of installation and
commissioning.

The system continuously checks the functionality of each
device and will immediately notify staff if any problem is
detected. The Zone Tone Sounder is hot swappable, making
maintenance a breeze – simply replace a sounder and then
use a browser to configure the device.

www.austco.com

Easy to Hear Wide Coverage

This sounder incorporates a speaker that provides The Zone Tone Sounder can be connected to multiple
clear, undistorted audio that replicates the chime speakers with amplifiers to extend the area of
Annunciator audio sequence, allowing staff to quickly notification such as a whole ward.
identify the type of active call.
All sounders are connected on the IPnet Nurse Call Volume Level
AN to all other components of the Tacera system.
The output volume can be set by adjusting the trimpot
SPECIFICATIONS accessible from the faceplate using a jewelers
screwdriver.

Feature IP-ZTS/O Description IP-ZTS/O/BS Description

Height 116 mm (4.57 in) 5 mm ( . in)
Width 76 mm (2.99 in) 5 mm ( . in)
Depth
Weight 45 mm (1.77 in) 45 mm (1.77 in)
Mounting 150 grams (5.29 oz)
Plate Screw on 6. grams ( . oz)
Austco Modular Plate Screw on
all Box Size Standard Size all Box Austco Modular Plate
Housing
Connectors all Box Standard Australian Size all Box
Cable Modular 8P8 C all Box
Temperature
CAT6 STP cable Modular 8P8 C
umidity ange -5 C( - )
Power CAT6 STP cable
0-85% Non Condensing
Compliance PoE ( . af or later) power -5 C( - )

0-85% Non Condensing

PoE ( . af or later) power

CSA . No. 6 6 - - - Audio/ ideo, Information and Communication Technology Equipment - Part
Safety equirements

EN 55 5 Electromagnetic Compatibility of Multimedia Equipment

EN 55 5 Electromagnetic Compatibility of Multimedia Equipment - Immunity equirements

EN 6 - - Electromagnetic compatibility (EMC). imits. imits for harmonic current emissions
(equipment input current 6 A per phase)

EN 6 - - Electromagnetic Compatibility (EMC) - PA T - imits - imitation of oltage Changes,
oltage luctuations and licker in Public ow- oltage Supply Systems, for Equipment with ated
Current 6 A Per Phase and Not Subject to Conditional Connection

CE Mark (European Conformity)

IEC 6 6 - Audio/video, information and communication technology equipment - Part Safety requirements

CM ( egulatory Compliance Mark)
U 6 ospital Signaling and Nurse Call Equipment (IP-ZTS/U only)

TM -

ORDERING INFORMATION

Product Code Description Order Options
IP-ZTS/O IP Zone Tone Sounder with Output Note Zone Tone Sounders do not include surrounds.
IP Zone Tone Sounder with Output British Style
IP-ZTS/O/BS
IP-ZTS/U IP Zone Tone Sounder U
IP-AM-CSP Chime Speaker with Amplifier

Austco Communications Systems PT td.
All rights are reserved.
Austco Communications Systems PT td. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

• Full Duplex VoIP for 2 way speech IP PATIENT STATION
• Total in Room Communication Solution FLUSH MOUNT
• Light control functions, TV & Entertainment
• Full range of IPNet callpoints/devices IP-PST-F/BE

IP Patient Station

The IP Patient Station is a slimline wall/bed head unit - which can be
used either - per single-bed room or one per bed in a multi-bed
room - providing a complete in-room patient call and audio
solution. The three on-board call buttons and cancel button allow
nurse calls, such as; presence, staff assist, code blue, to be directly
supported on the unit thereby, saving on additional call points. For
additional flexibility, the set of call types offered on these buttons
can be changed.

The IP Patient Station is suited for structured cabling where each
room/bed requires only a single CAT cable to the IP Patient Station.
Furthermore, its on-board full-duplex audio allows staff to be in
contact with the patient and using VoIP SIP allows for simple
connectivity.

Devices such as Austco pendants, handsets, multi-functional
handsets auxiliary input, over-bed lamp and flexible dual relay can
all be directly connected to the unit.

Easy to Identify and Use IP Patient Station has Multiple
Device Connectivity
The call can be activated by momentarily pressing one or more of
the three call buttons (labelled with its function) or through the
call button on Austco’s pendant or multifunction handset. The
audio is full duplex and requires no button presses to activate a
call, making it a full hands free operation.

For an easy identification, the call buttons have a hard wearing
epoxy caps, which clearly indicate the function, and backlighting,
which provides easy location and operation at night. Additionally,
once the call button is pressed, a tone sounder buzzer and
reassurance LED behind the cancel button appears, giving
patients the reassurance that their call has been placed.

When a pendant is removed, either accidentally or intentionally, the IP Patient Station will generate a pendant out
alarm. Furthermore, the IP Patient Station’s modern design allows for the pendant cable to breakaway if pulled abruptly,
limiting the risk of damage to equipment or injury to the patient.

www.austco.com CS-045, Rev. A

To avoid nuisance alarms during cleaning, the IP Patient Station Ente ta n ent
incorporates a cleaning mode. The cleaning time and date is logged
on the central server, providing an important audit trail for infection IP Patient Station when coupled with the IP-EM multifunction
control compliance. handset, provides a pillow speaker based TV entertainment solution.
The TV sound is routed to the IP-EM loud speaker, providing quality
ur superior product design provides flexibility to the facility to sound on the pillow and reducing the ward background sound.
change any room layout at any time without additional corridor Additionally, TV on/off, volume, channel changing controls are
cabling or networking equipment. Furthermore, if an additional room supported directly on IP-EM and communicates to the TV using
or ensuite call point is required, it can be connected directly to the IP serial direct or IR connection or IP messaging over Ethernet.
Patient Station via its two IPnet patient area network ports.
Insta ation
onne ti ty
The IP-Patient Station can be mount flush on the wall
The IP Patient Station requires a single CAT cable to be connected or panel mounted into a medical service panel and incorporates
to the room/bed and PoE for total room device powering or V, rear connector options for straight and right angle facing down.
Addtionally, IP Patient Station can be directly connected to up to Additionally, an spacer is available as an option for surface mount
Austco IPnet call points, digital handsets , pendants, over door and a rear plastic cover is available for straight connector option.
lights, zone tone sounders - including those in ensuite. Furthermore, the equipment is compatible with wall boxes from
Clipsal, ESC and S gang.
SPECIFICATIONS

Feature es tion

eight . mm ( . )
Width
Depth mm ( . ")
Weight mm ( . ")
Mounting Method
Ethernet . oz ( grams)
IPnet Flush mounted on wall or in medical service panel. Surface mount spacer available

Call uttons x R , Mbit/s, PoE IEEE . at ( -event Classification only)
Cancel utton
Audio x R connectors, Maximum devices

ver ed Lamp x Call buttons, flexible call type, backlit, Refer to AM-PST buttons caps. Can be used for pendant enable.
Relay
Pendants Cancel button
Full duplex, VoIP using SIP, LED indicator
Digital andset
Current Consumption x pin header. Suites CM-DM
Temperature
x pin header. Control is pulsed signal suitable for RL - or
umidity Range x . mm stereo jack. Flexible N /NC, button enable, delay. Suites pendants CP-PCP, CP-SCP, CM-PM, CS-PMPAD,
Compliance bed mats, floor mats, medical devices

x S Type A latching. May require AMTV S . Suits IP-EM

During Intercom Call mA (Does not include consumption of connected IPNet devices)

C ( - F)
Non Condensing
EN
EN
EN -
CE Mark of European Conformity
L th edition
L st edition
CFR, Part Subpart Class A
CAN/CSA . No.
TM -

ORDERING INFORMATION

Product Code es tion Orde tions
IP-PST-F/BE Flush Mount VoIP Patient Station Call buttons - Refer to AM-PST uttons.

Surface mount spacer available.

Austco Communications Systems PT Ltd.
All rights are reserved.
Austco Communications Systems PT Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice
or obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

IP GENERIC CALLPOINT
IP-CPG
IP-CPG/BS

• Hard-wearing and washable IP-CPG
• Anti-bacterial protection with Infection Control
• Fully Supervised Callpoint, with backlight
• Pendant Removal Alarm
• “Three Button Press” for Emergency Calls

IP Generic Callpoint Optional 6.5mm
Pendant Socket
Large and easy to activate, the Austco call button provides a Bright reassurance
positive tactile response when pressed. This makes it ideal for LED
patient/residents with restricted or limited movement. IP-CPG/BS

Standard features include back lit buttons for night viewing by Optional 8 pin DIN Pendant Socket
residents and patients, a reassurance LED and tone sounder for TV control for both versions
for audibly or visually impaired patients, and call mute mode CHANGEABLE INSERTS
for cleaners. MUST BE ORDERED
SEPARATELY
Callpoints are designed for changeable inserts as shown in
picture. The call button insert design enables a facility to swap CS-046, Rev. B
out and replace the current call button instead of needing to
replace the whole Callpoint. For example, if a facility had a
Staff Assist Callpoint in a room and now wanted that Callpoint
to be an Emergency Callpoint, they simply swap out the Staff
Assist button insert for an Emergency Call insert and
reconfigure to alert as an Emergency Call on the system when
pressed. With this added flexibility and low maintenance
feature the facility can work out which alerts need to be
where, long after the initial install. This helps to drive
workflow efficiencies throughout their healthcare organisation
thus increasing patient care.

Lower “Whole-of-Life” Costs

IP Generic Callpoints are IPnet and feature plug-and-play
functionality. They are connected in series using standard CAT5/6
cable that also provides POIPnet (Power Over IPnet).

Each callpoint has a unique address and is supplied configured for
immediate use. Once connected, the callpoint is quickly and easily
assigned to a room using a browser, which simplifies the
installation process and reduces the cost of installation and
commissioning.

www.austco.com

The system continuously checks the functionality of each callpoint These ergonomic callpoints are flush, wall mounted with a
and will immediately notify staff if any problem is detected. configurable CALL button. Each callpoint has a separate CANCEL
Callpoints are hot swappable, making maintenance a bree e, simply button that illuminates red, giving visual reassurance that a call has
replace a callpoint and then use a browser to quickly configure the been initiated. All callpoints are connected on the Nurse Call LAN to
device. all other components of the Tacera system to initiate
communication between nursing staff and patients.
Easy to Identify and Use
Improved Infection Control
Callpoints feature soft-touch push buttons that are clearly labelled
with text or icons for easy and fast identification. The CALL button is Both buttons are manufactured from silicone rubber with an
available in a number of standard colours and icons, allowing the anti-bacterial additive for improved infection control.
system to operate a variety of alarm levels and system inputs as To avoid nuisance alarms during cleaning, the callpoint incorporates
determined by the protocols of your facility. a cleaning mode. The cleaning time and date is logged on the
The callpoint can be configured to allow active calls to be upgraded central server, providing an important audit trail for infection
to a higher level by pressing the CALL button three times or holding control compliance.
it for three seconds. This feature can eliminate the need for separate
staff assist buttons thus further reducing infrastructure costs. External Lamp Indicator

SPECIFICATIONS An over door lamp indicator can be added to display the call status.

Feature IP-CPG Description IP-CPG/BS Description
Height 85 mm ( . in)
Width 116 mm (4.57 in) 85 mm ( . in)
Depth 76 mm (2.99 in) 45 mm (1.77 in)
Weight
Mounting 25 mm (1.02 in) grams ( . o )
Plate grams ( . o ) Screw on
Wall Box Si e Austco Modular Plate
Housing Screw on Standard Australian Si e Wall Box
Connectors Austco Modular Plate Wall Box
Standard North American Si e Wall Box Ipnet xR5- 5 socket, External lamp indicator
Cable Wall Box 2-pm screw terminal (AWG 24)
Ipnet xR5- 5 socket, External lamp indicator CAT5 or CAT6, (AWG ) Data / Security cable
Temperature 2-pm screw terminal (AWG 24) to over bed indicator light
Humidity Range CAT5 or CAT6, (AWG ) Data / Security cable
to over bed indicator light - 5 C ( - F)
Compliance -85 Non Condensing
- 5 C ( - F)
, EN 6 - - 5, EN 6 - - 5, EN 6 - -
-85 Non Condensing

UL 6 th edition

UL 56 st edition

CFR, Part 5 Subpart B Class A and B

CAN/CSA . No 5

EN 55

EN 55

EN 6 -6- , EN 6 - - 5, EN 6 - - 5, EN
6 - -5 5, EN 6 - -6 6, EN 6 - -

EN 6 68- , report -A6 -CB-

AS/N S CISPR

ORDERING INFORMATION

Product Code Description Product Code Description
IP-CPG/BS IP Callpoint General, British Style
IP-CPG IP Callpoint General IP-CPG/BS/P IP Callpoint General With Pendant Socket, British Style

IP-CPG/P IP Callpoint General With Pendant Socket

Order Options for IP-CPG /H - (Hori ontal Callpoint)

Note Please see AM-CPG Generic Callpoint Inserts cut sheet for options.

Austco Communications Systems PTY Ltd.
All rights are reserved.

Austco Communications Systems PTY Ltd. reserves the right to make changes in specifications and/or discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

www.austco.com

RESIDENT CHECK-IN
IPC-RCI

• Informs the Staff which residents have not checked-in
• Maintains a log of which residents have not checked-in
• Optional audible message notifications
• Check-in button conveniently located on Austco bedside

device or pillow speaker

Resident Check-In

Austco’s Resident Check-In feature allows residents to “check-in” with the press of a
button which notifies the care team that the resident is awake and is ready to start
their day. While this feature is typically used for morning check-ins,
the check-in period can be designated to be used any time of the day.

The daily check-in monitoring period is configured within the
system and residents may receive an optional audible
notification message advising them to check-in. The IPC-AUDIO
license is required for audio notifications. Residents can then
press the check-in button on their Austco pillow speaker, call
pendant or patient station button to notify care teams that they
have checked-in. Residents will then receive a notification to
acknowledge their check-in.

How it Works

If the resident fails to check-in within a pre-configured
amount of time after the initial notification message, a
reminder notification message will occur reminding them
that the check-in window is closing soon and to please
check-in. If the resident still does not check-in after the
check-in period, an alarm will be activated and displayed on
the master station and other rostered devices including staff
smartphones using Pulse Mobile.
When residents have not checked-in, an alarm is activated. The
Tacera Nurse Call System will log this alarm which can be
generated into a report. Staff can then quickly follow-up with
residents who have not yet checked-in.

ORDERING INFORMATION

Product Code Description Order Options
N/A
IPC-RCI Software License for Resident Check-In N/A

IPC-AUDIO License for VoIP Audio enabled communications (Optional)

www.austco.com CS-047, Rev. A


Click to View FlipBook Version