M&E PPM Quick Reference with Log Sheets

M&E PPM Quick Reference with Log Sheets

MIRHCT Leeds General Infirmary

Quick Reference Maintenance Guide

MECHANICAL & ELECTRICAL PPM

Item. Frequency Manufacturer Manual Location Notes
D W M 3M 6M 9M 1Y
MECHANICAL The frequency of some routines may need to be increased subject to individual
requirements. Failure to maintain the system to the minimum
Ventilation XXXX X Quartz HPI Section 3 recommendations could result in the warranty becoming null and void.
Fancoil Units XXXX Reference should be made to the manufacturers information for specific routine
X Barkell HPI Section 3 maintenance and frequencies.
Air Handling Units Equipment is of passive nature and therefore requires no routine maintenance,
X Allaway Acoustics Limited HPI Section 3 lubrication or spares. Visual inspection should be carried out at least once a
Attenuators X X X Actionaire HPI Section 3 year.
X X X General Maintenance Note HPI Section 3 Fire damper tests to be carried out annually.
Fire Dampers (Smokeshield) X Helios HPI Section 3 Check all duct joints and access panels are airtight, reseal as necessary.
Ductwork XXX X The first maintenance should be carried out three months after commissioning
Extract Fans and thereafter at 12 monthly intervals.

Grilles & Diffusers XX X Gilberts (Blackpool) Limited HPI Section 3 Weekly observational checks required & cleaning as required.

Heating & Cooling Systems

Heater Batteries X X SP Coils HPI Section 3 Regular observational checks & annual service by a qualified professional.
X Boss HPI Section 3 The combined low loss header and air/dirt separator requires maintenance at
Chemical Dosing Pot & Combined Low Loss Header Air/Dirt X X Wilo UK Limited HPI Section 3 least once a year. Inspect dosing pot daily and clean annually.
Separator X Wilo UK Limited HPI Section 3 Regular observational checks & service per year.
X ICS HPI Section 3 Regular observational checks & service per year.
Pressurisation Unit & Expansion Vessel X X Solray Tridant HPI Section 3 Regular observational checks & service per year.
X Condair HPI Section 3 Page 69 Inspect for leaks and remove any dust and dirt built-up from heating surface.
Pumps XX HPI Section 3 Integral monitoring system + annual inspection
Kingspan HPI Section 3 Check insulation is securely in place and inspect for any stains which could be
MRI Chilled PHX XX X Boss signs of leakage. Check identity bands are in place and visible.
HPI Section 3 Periodically inspect filter and change as necessary
Radiant Panels General Maintenance Note Systems to be checked every 3 months for fall in chemical levels & levels to be
HPI Section 3 checked/topped up after any works carried out on system. Refer to water
Humidifiers General Maintenance Note treatment specialist's log book further details.
HPI Section 3
Thermal Insulation X General Maintenance Note Systems to be checked every 3 months for fall in chemical levels & levels to be
HPI Section 3 checked/topped up after any works carried out on system. Refer to water
Side Stream Filter X Armitage Shanks HPI Section 3 treatment specialist's log book further details. (Please note Derived from
X General Maintenance Note Clarendon Chilled Main not water treatment in place)
Water Treatment to LTHW X HPI Section 3
General Maintenance Note Systems to be checked every 3 months for fall in chemical levels & levels to be
Water Treatment CHW Primary Circuit X checked/topped up after any works carried out on system. Refer to water
treatment specialist's log book further details.
Water Treatment CHW Secondary Circuit PHX-MRI X
X Weekly checks required.
Utility Systems Annual temperature check. (Integral Armitage Shanks)
Sanitaryware & Fittings Refer to notes
Thermostatic Mixing Valves X Regular water draw off regime required to any unused outlets. Please note
XX DWS are connected to Existing Clarendon Mains, Existing Hospital Protocols in
Water Treatment (to Domestic Water Systems) operation (Sentinel Monitoring Installed see BMS )
X
Specialist Systems X Eon HPI Section 5 Daily observational checks & service per year.
BMS Controls XX
X Hospital Pipeline See Dedicated Manual Daily observational checks before use, Specialist Knowledge Required. This
Medical Gas Installation Installations system is an extension grafted onto the existing Clarendon Medgas System.
Trust existing protocols to be followed.
LV Switchgear, Distribution & Small Power
Distribution Boards ELECTRICAL
Electrical Distribution (Sub - Main Cables)
Main LV Switchboard X Schneider Electrical Section 2 part 2.2 & 2.2 Existing adjustments should not be disturbed unless absolutely necessary. An
Lighting X General Maintenance Note Section 2 part 2.2 & 2.2 inspection should always be made as soon as possible after a circuit fault.
Light Fittings (Emergency) X Schneider Electrical Section 2 part 2.2 & 2.2
Visual periodic inspection.

Existing adjustments should not be disturbed unless absolutely necessary. An
inspection should always be made as soon as possible after a circuit fault.

X Advanced Section 2 part 2.5 Daily operational checks. Monthly and yearly system tests. Please note
Advanced System is grafted onto existing system (extension thereon)

Light Fittings (General) X X Southgate & Whitecroft Section 2 part 2.4 General examination for cleanliness and correct operation. All fittings are LED

Specialist Systems

Nurse Call X X Static Systems Section 4 part 4.9 This system is an extension grafted onto the existing Clarendon System. Trust
existing protocols to be followed.

Fire Alarm System XX X Autronica Chubb Section 2 part 2.6 This system is an extension grafted onto the existing Clarendon System. Trust
existing protocols to be followed.

Lightning Protection System X Michael Jackson Section 5 part 5.11 Annual test and observational inspection of all connections and down
conductors. Observational checks following lightning strike.

Weekly operational checks. Monthly checks. 3 Monthly full functional test. This

Access / CCTV XXX Openview Section 4 part 4.6 system is an extension grafted onto the existing Clarendon System. Trust

existing protocols to be followed.

Structured Cabling System X Dataflow Section 4 part 4.7 Check set up/connections & clean cabinet. Visual inspection of cabling and
outlets. Structured cabling emanates from existing Cabinet in CD void

Weekly / Monthly / Annual inspection Required. Due to the specialist nature of

UPS / IPS XX X X Bender Section 4 part 4.4 & 4.5 equipment Trust is advised to enter into a service agreement with an

appropriate specialist.

BAM AFTERCARE

Item Frequency Notes
D W M 3M 6M 9M 1Y

BAM Aftercare Manager Post Handover Courtesy Visit Sign BAM Aftercare Manager will meet with the client team on a Quarterly basis
Offs discuss the maintenance schedule and will require proof that the elements
noted have been done in order to sign of this section.

This is a guide for the 12 months inspections to ensure all equipment seeks to function correctly and does not invalidate any warranties. The user is responsible for their own 12 months maintenance plan and service. All

maintenance work must be carried out by a suitably trained and qualified person. RAMS need to be in place before starting any maintenance work.

Compiled 12/03/2019 Please refer to you full Operations and Maintenance Manual for more detail on these items Page 1 of 36

System Maintenance Log Sheet

Item Fancoil Units Maintenance Frequency
Manufacturer Quartz
D W M 3M 6M 9M 1Y
Date
XXXX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Air Handling Units Maintenance Frequency
Manufacturer Barkell
D W M 3M 6M 9M 1Y
Date
XXXX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Attenuators Maintenance Frequency
Manufacturer Allaway Acoustics Limited
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Fire Dampers Maintenance Frequency
Manufacturer Actionaire
D W M 3M 6M 9M 1Y
Date XXX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Ductwork Maintenance Frequency
Manufacturer General Maintenance Note
D W M 3M 6M 9M 1Y
Date XXX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Extract Fans Maintenance Frequency
Manufacturer Helios
D W M 3M 6M 9M 1Y
Date XXX X X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Grilles & Diffusers Maintenance Frequency
Manufacturer Gilberts (Blackpool) Limited
D W M 3M 6M 9M 1Y
Date
XX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Heater Batteries Maintenance Frequency
Manufacturer SP Coils
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Chemical Dosing Pot & Combined Low Loss Header Air/Dirt Separator Maintenance Frequency
Manufacturer Boss
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Pressurisation Unit & Expansion Vessel Maintenance Frequency
Manufacturer Wilo UK Limited
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Pumps Maintenance Frequency
Manufacturer Wilo UK Limited
D W M 3M 6M 9M 1Y
Date
XX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item MRI Chilled PHX Skid Maintenance Frequency
Manufacturer ICS
D W M 3M 6M 9M 1Y
Date
XX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Radiant Panels Maintenance Frequency
Manufacturer Solray Tridant
D W M 3M 6M 9M 1Y
Date XXX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Huminifiers Maintenance Frequency
Manufacturer Condor
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Thermal Insulation Maintenance Frequency
Manufacturer Kingspan
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Side Stream Filter Maintenance Frequency
Manufacturer Boss
D W M 3M 6M 9M 1Y
Date
XX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Water Treatment LTHW Maintenance Frequency
Manufacturer General Maintenance Note
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Water Treatment CHW Primary Maintenance Frequency
Manufacturer General Maintenance Note
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Water Treatment Secondary Circuit Maintenance Frequency
Manufacturer General Maintenance Note
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Sanitaryware & Fittings Maintenance Frequency
Manufacturer Various
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Thermostatic Mixing Valves Maintenance Frequency
Manufacturer General Maintenance Note (integral Armitage Shanks)
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

Item System Maintenance Log Sheet Maintenance Frequency

Manufacturer Water Treatment to Domestic Regular water draw off regime
Date General Maintenance Note required to any unused outlets.
Refer to water treatment specialist's
log book for frequencies and further
details.

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item BMS Controls Maintenance Frequency
Manufacturer Eon
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item BMS Controls Maintenance Frequency
Manufacturer Hospital Pipeline Systems
D W M 3M 6M 9M 1Y
Date XXX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Distribution Boards Maintenance Frequency
Manufacturer Schneider
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Electrical Distribution (Sub - Main Cables) Maintenance Frequency
Manufacturer General Maintenance Note
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item LV Panelboards Maintenance Frequency
Manufacturer Schneider
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Emergency Lighting Maintenance Frequency
Manufacturer Advanced Electronic
D W M 3M 6M 9M 1Y
Date XXXX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Light Fittings (General) Maintenance Frequency
Manufacturer Southgate & Whitecroft
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Nurse call Maintenance Frequency
Manufacturer Static Systems
D W M 3M 6M 9M 1Y
Date XX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Fire Alarm System Maintenance Frequency
Manufacturer Chubb
D W M 3M 6M 9M 1Y
Date
XX X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Lightning Protection System Maintenance Frequency
Manufacturer Michael Jackson Lighting Protection
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Access / CCTV Maintenance Frequency
Manufacturer Openview
D W M 3M 6M 9M 1Y
Date XXX

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item Structured Cabling System Maintenance Frequency
Manufacturer Dataflow
D W M 3M 6M 9M 1Y
Date X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance

System Maintenance Log Sheet

Item UPS / IPS Maintenance Frequency
Manufacturer Bender
D W M 3M 6M 9M 1Y
Date XX X X

Maintenance Carried Out Person Carrying Out Log Of Issues Encountered
Maintenance