2023 Service Package - THE DOITUNG DEVELOPMENT PROJECT

THE DOITUNG DEVELOPMENT PROJECT

Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Precise - - 4.58 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 1000 kVA อาคาร 2 0.95 CT,PT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 36.10 NORMAL 37.10 NORMAL FALSE 37.00 NORMAL FALSE 36.70 NORMAL FALSE 37.00 NORMAL Priority RECOMMENDED ACTION FALSE - - FALSE 38.10 NORMAL 1.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 38.20 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.10 - ระบบเป็นปกติ 1.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 48


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Precise - - 2.71 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 1000 kVA อาคาร 2 0.95 บุชชิ่งแรงสงู IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 50.50 NORMAL 41.20 NORMAL FALSE 42.20 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 5.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 47.10 3.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 4.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 49


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Precise - - 1.55 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 1000 kVA อาคาร 2 0.95 บุชชิ่งแรงต่ า IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 43.40 NORMAL 35.90 NORMAL FALSE 41.20 NORMAL FALSE FALSE 40.70 NORMAL Priority RECOMMENDED ACTION FALSE FALSE 0.30 - ระบบเป็นปกติ (P0) 35.60 7.80 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 5.60 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 5.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 50


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 1000 kVA อาคาร 2 0.95 Main Circuit Breaker 1600AT 50% Schneider Electric - - 0.61 230 / 400 25.00 1600 7 March 2566 - 15.00-16.00 IR THERMOGRAMS AND VISIBLE LIGHT IMAGES TECHNICAL DATA IR Thermograms Visible Light Image FALSE 31.30 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE 31.80 NORMAL FALSE 31.20 NORMAL FALSE 30.50 NORMAL FALSE 30.40 NORMAL FALSE - - FALSE 32.80 NORMAL Priority RECOMMENDED ACTION 2.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 29.80 3.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.60 - 1.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by ระบบเป็นปกติ 0.70 - ระบบเป็นปกติ Priority RECOMMENDED ACTION 1.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.70 - ระบบเป็นปกติ 1.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 51


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 6.46 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 500 kVA อาคาร 1 0.95 Drop Out fuse IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 36.10 NORMAL 36.20 NORMAL FALSE 36.20 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 3.70 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 32.50 3.60 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 3.70 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 52


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Precise - - 6.46 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 500 kVA อาคาร 1 0.95 CT,PT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 36.70 NORMAL 37.60 NORMAL FALSE 36.40 NORMAL FALSE 36.50 NORMAL FALSE 36.20 NORMAL Priority RECOMMENDED ACTION FALSE - - FALSE 38.10 NORMAL 0.50 - ระบบเป็นปกติ (P0) 37.10 0.40 - ระบบเป็นปกติ 0.70 - ระบบเป็นปกติ 1.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.90 - ระบบเป็นปกติ 0.60 - ระบบเป็นปกติ Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 53


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Precise - - 6.46 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 500 kVA อาคาร 1 0.95 บุชชิ่งแรงสงู IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 47.00 NORMAL 40.20 NORMAL FALSE 48.30 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 4.70 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 44.90 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 3.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 54


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Precise - - 2.65 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 500 kVA อาคารประกอบ 1 0.95 บุชชิ่งแรงต่ า IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 14.00-15.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 41.10 NORMAL 40.70 NORMAL FALSE 39.40 NORMAL FALSE FALSE 43.00 NORMAL Priority RECOMMENDED ACTION FALSE FALSE 1.70 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 39.00 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.40 - ระบบเป็นปกติ 4.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 55


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Square D - - 1.61 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข1, 2 INSPECTION DETAIL FLUKE Ti480P S/N 18100128 TR 500 kVA อาคารประกอบ 1 0.95 Main Circuit Breaker 800AT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 800 7 March 2566 - 15.00-16.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 28.40 NORMAL 28.20 NORMAL FALSE 28.20 NORMAL FALSE 27.60 NORMAL FALSE 28.10 NORMAL Priority RECOMMENDED ACTION FALSE - - FALSE 27.80 NORMAL 0.20 - ระบบเป็นปกติ (P0) 28.00 0.40 - ระบบเป็นปกติ 0.20 - ระบบเป็นปกติ 0.20 - ระบบเป็นปกติ 0.10 - ระบบเป็นปกติ 0.40 - ระบบเป็นปกติ 0.60 - ระบบเป็นปกติ Tested by Witnessed by Priority RECOMMENDED ACTION 0.10 - ระบบเป็นปกติ 0.60 - ระบบเป็นปกติ 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 56


F I E L D I N S P E C T I O N T E S T R E C O R D DOITUNG ROYAL VILLA อ า ค า ร ป ร ะ ก อ บ ห ม า ย เ ล ข 5 PAGE 57


Customer : Location : Distribution Transfromer : Phase Sealed type Conservator type Dry type VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS EARTHING RESISTANCE MEASUREMENT FAIL PASS PASS with condition HV to GND : GΩ LV to GND : GΩ HV to LV : GΩ Note : Should be more than 1 GΩ or 1000 MΩ High voltage TR. : Ω Low voltage TR. : Ω Low voltage MDB. : Ω Generator : Ω Note : Should be less than 5 Ω, or 5- 25 Ω with condition Responsibility Signature Name Date เปลี่ยนSilica Gel Capacitor Bank LV Terminal Oil Level Indicator Oil drain value check Thermometer Buchholz Relay Pressure- Relief Device High voltage fuse Low voltage fuse Tank and Fin HV Bushing and Gasket LV Bushing and Gasket Cover Gasket Tap Changer Gasket HV Terminal Dehydrating breather (Silica gel) 721.69 001262 3 PRECISE 2003 50 Dyn 11 500 ONAN 22000 400 / 230 A A 60 66 - 7.39 339 - 1815 46-003381 Rated Power Type of cooling Rated voltage HV Rated voltage LV Hz kVA V V Serial No. Tap Position K K °C % Litre kg kg 13.12 27 March 2023 27 March 2023 3 Tested by Witnessed by การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย VISUAL INSPECTION TECHNICAL DATA Rated current HV Rated current LV Oil Temperature rise Winding Temperature rise Max ambient temperature Impedance voltage Oil Quantity Untank mass Total mass PEA No. Manufacture Year of manufacture Rated Frequency Vector Group Symbol CHECKLIST การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD TRANSFORMER AND GROUNDING GENERAL INFORMATION อาคารประกอบหมายเลข5 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ INSULATION RESISTANCE MEASUREMENT EARTHING RESISTANCE MEASUREMENT 7.20 10.00 2.00 1000 500 1000 Test Voltage (Vdc) COMMENTS AND RECOMMENDATION : Grounding Resistance 2.60 - - COMMENTS AND RECOMMENDATION : PAGE 58


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS Manufacture : Type : Sizing / Bundle : Wiring method : Length : Rated current : Rated voltage : Connected with : ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า FAIL PASS จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง FAIL PASS ปลดฟิวส์control ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายcontrol ออกจากสายตัวน าประธาน เชื่อมต่อสายที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าประธานออกจาก Main Circuit Breaker แจ้งทีม maintenance หม้อแปลงก่อนเริ่มทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันที่สายไฟ A - (G,B,C) : GΩ ที่ทดสอบเทียบกับสายอื่นต่อลงดินค่าความต้านทานฉนวน B - (G,A,C) : GΩ ต้องมากกว่า 1 MΩ หรือ0.001 GΩ C - (G,A,B) : GΩ Responsibility Signature Name Date การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN FEEDER 1068 A. INSULATION RESISTANCE MEASUREMENT 5 ที่ 1 2 3 4 600 / 1000 V. TR 500 kVA to Main CB 800 AT รายละเอียด VISUAL INSPECTION จุดที่ตรวจสอบ 4.15 0.94 0.81 ที่ระยะเวลา 1 นาทีมาตรฐาน : Witnessed by นายธีรพงษ์ค าใหญ่นายณวรา ชนยุทธ COMMENTS AND RECOMMENDATION : 27 March 2023 27 March 2023 GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข5 รายละเอียด ผลการทดสอบ หมายเหตุ CHECKLIST TECHNICAL DATA ผลตรวจสอบ 1000 Tested by Bangkok Cable CV 4x185 Sq.mm. / 3 Bundle underground 100 m. PAGE 59


Customer : Location : Circuit Breaker Manufacture : Series : Breaking Capacity : AT. VISUAL INSPECTION FAIL PASS FAIL PASS CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT FAIL PASS Main CB. สามารถ Operate ON-OFF ได้ FAIL PASS Main CB. สามารถทดสอบ TRIP-TRIP FREE ได้ FAIL PASS Aux. CB. ทดสอบปลดวงจรจากshunt trip/under, voltage release FAIL PASS ช่องดับอาร์ก ต้องไม่มีสภาพเสยีหายทางกลและรอยไหม้ FAIL PASS หน้าสมัผัสหลัก ต้องไม่มีสภาพสกึหรอรอยไหม้และรอยออกไซด์ FAIL PASS กลไกทางกล ต้องไม่มีสิ่งแปลกปลอมไปขัดกลไกท างาน FAIL PASS ปลดฟิวส์control ปลดสายตัวน าประธานออกจากหม้อแปลงไฟฟ้า ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar แจ้งทีม maintenance TR- MDB. ก่อนทดสอบ Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - a : GΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - b : GΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - c : GΩ กระแสทดสอบ: 100 A ที่ระยะเวลา 1 นาที A ค่าความต้านทานหน้าสมัผัสCircuit Breaker ควรมีค่าต่ า A - a : µΩ โดยค่าความต้านทานหน้าสมัผัสควรมีค่าใกล้เคียงกัน B - b : µΩ ทั้งสามเฟสหากค่าความต้านทานหน้าสมัผัสมีผลต่าง C - c : µΩ เกินกว่า 50% ให้ท าการตรวจสอบเบื้องต้นและเฝ้าระวังต่อไป Responsibility Signature Name Date รายละเอียด ผลการทดสอบ หมายเหตุ การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN CIRCUIT BREAKER GENERAL INFORMATION CHECKLIST โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข5 Schneider Electric NS1000N 800 27 March 2023 Tested by Witnessed by นายธีรพงษ์ค าใหญ่ 27 March 2023 นายณวรา ชนยุทธ INSULATION RESISTANCE MEASUREMENT จุดที่ตรวจสอบ ผลตรวจสอบ VISUAL INSPECTION ที่รายละเอียด INSULATION RESISTANCE MEASUREMENT 6 1 2 3 5 4 COMMENTS AND RECOMMENDATION : ควรลดขนาดปรับตั้งของเมนเบรกเกอร์ให้สมัพันธ์กับค่ากระแสสงูสดุของหม้อแปลงไฟฟ้า (Rated current LV : 721.69 A) 1000 ที่ระยะเวลา 1 นาที > 200 > 200 > 200 มาตรฐาน : 100 ที่ระยะเวลา 1 นาที 113.20 145.60 153.10 มาตรฐาน: CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT PAGE 60


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS ปลดฟิวส์control Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แจ้งทีม maintenance MDB. ก่อนทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - (G,B,C) : GΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - (G,A,C) : GΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - (G,A,B) : GΩ Responsibility Signature Name Date VISUAL INSPECTION ที่จุดที่ตรวจสอบ รายละเอียด ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย CHECKLIST รายละเอียด ผลการทดสอบ หมายเหตุ 27 March 2023 27 March 2023 Tested by Witnessed by นายธีรพงษ์ค าใหญ่นายณวรา ชนยุทธ การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN BUSBAR GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารประกอบหมายเลข5 ผลตรวจสอบ INSULATION RESISTANCE MEASUREMENT 1000 ที่ระยะเวลา 1 นาที 5 จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง 6 Bus bar ต้องไม่มีรอยไหม้โค้งและโก่งงอ 7 ตัวยึดฉนวน ต้องไม่มีรอยร้าวและรอยแตกไหม้ 3 จุดเข้าสาย CB. COMMENTS AND RECOMMENDATION : 1.49 0.68 0.91 มาตรฐาน : 4 จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า 1 ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย 2 จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย PAGE 61


F I E L D I N S P E C T I O N T E S T R E C O R D DOITUNG ROYAL VILLA บ้ า น พั ก รั บ ร อ ง PAGE 62


Customer : Location : Distribution Transfromer : Phase Sealed type Conservator type Dry type VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS EARTHING RESISTANCE MEASUREMENT FAIL PASS PASS with condition HV to GND : GΩ LV to GND : GΩ HV to LV : GΩ Note : Should be more than 1 GΩ or 1000 MΩ High voltage TR. : Ω Low voltage TR. : Ω Low voltage MDB. : Ω Generator : Ω Note : Should be less than 5 Ω, or 5- 25 Ω with condition Responsibility Signature Name Date พบรอยวาปไฟตามผิว เปลี่ยนSilica Gel Capacitor Bank LV Terminal Oil Level Indicator Oil drain value check Thermometer Buchholz Relay Pressure- Relief Device High voltage fuse Low voltage fuse Tank and Fin HV Bushing and Gasket LV Bushing and Gasket Cover Gasket Tap Changer Gasket HV Terminal Dehydrating breather (Silica gel) 721.69 0007404 3 PRECISE 2003 50 Dyn 11 500 ONAN 22000 400 / 230 A A 60 65 - 7.46 339 - 1815 44-003376 Rated Power Type of cooling Rated voltage HV Rated voltage LV Hz kVA V V Serial No. Tap Position K K °C % Litre kg kg 13.12 18 March 2023 18 March 2023 3 Tested by Witnessed by การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย VISUAL INSPECTION TECHNICAL DATA Rated current HV Rated current LV Oil Temperature rise Winding Temperature rise Max ambient temperature Impedance voltage Oil Quantity Untank mass Total mass PEA No. Manufacture Year of manufacture Rated Frequency Vector Group Symbol CHECKLIST การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD TRANSFORMER AND GROUNDING GENERAL INFORMATION บ้านพักรับรอง ค่าความต้านทานดินด้านแรงสงู บุชชิ่ง เฟส A, C พบรอยวาปไฟตามผิว โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ INSULATION RESISTANCE MEASUREMENT EARTHING RESISTANCE MEASUREMENT 3.51 1.76 3.14 1000 500 1000 ค่าความต้านทานดินด้านแรงสงูมีค่าสงูแต่ทั้งนี้ยังอยู่ในเกณฑ์ที่ยอมรับได้ Test Voltage (Vdc) COMMENTS AND RECOMMENDATION : Grounding Resistance 12.00 - - COMMENTS AND RECOMMENDATION : PAGE 63


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS Manufacture : Type : Sizing / Bundle : Wiring method : Length : Rated current : Rated voltage : Connected with : ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า FAIL PASS จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง FAIL PASS ปลดฟิวส์control ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายcontrol ออกจากสายตัวน าประธาน เชื่อมต่อสายที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าประธานออกจาก Main Circuit Breaker แจ้งทีม maintenance หม้อแปลงก่อนเริ่มทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันที่สายไฟ A - (G,B,C) : MΩ ที่ทดสอบเทียบกับสายอื่นต่อลงดินค่าความต้านทานฉนวน B - (G,A,C) : MΩ ต้องมากกว่า 1 MΩ หรือ0.001 GΩ C - (G,A,B) : MΩ - พบการเชื่อมต่อสายไฟฟ้าไปยังวงจรอื่นโดยที่ไม่ผ่านอุปกรณ์ป้องกันหรือมีการเข้าปลายสายโดยไม่ใช้หางปลา Responsibility Signature Name Date การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN FEEDER 1068 A. INSULATION RESISTANCE MEASUREMENT 5 ที่ 1 2 3 4 600 / 1000 V. TR 500 kVA to Main CB. 1000 AT. รายละเอียด VISUAL INSPECTION จุดที่ตรวจสอบ 47.30 20.80 23.00 ที่ระยะเวลา 1 นาทีมาตรฐาน : Witnessed by นายพนภัทร ฐานานุกูล นายณวราชนยุทธ COMMENTS AND RECOMMENDATION : - ควรปิดช่องเดินสายเพื่อป้องกันไม่ให้สตัว์เข้าไปภายในตู้MDB และสร้างความเสยีหายแก่ระบบไฟฟ้า 18 March 2023 18 March 2023 GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ บ้านพักรับรอง รายละเอียด ผลการทดสอบ หมายเหตุ CHECKLIST TECHNICAL DATA ผลตรวจสอบ 1000 Tested by Bangkok Cable CV 4x185 Sq.mm. / 3 Bundle Underground 300 m. PAGE 64


Customer : Location : Circuit Breaker Manufacture : Series : Breaking Capacity : AT. VISUAL INSPECTION FAIL PASS FAIL PASS CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT FAIL PASS Main CB. สามารถ Operate ON-OFF ได้ FAIL PASS Main CB. สามารถทดสอบ TRIP-TRIP FREE ได้ FAIL PASS Aux. CB. ทดสอบปลดวงจรจากshunt trip/under, voltage release FAIL PASS ช่องดับอาร์ก ต้องไม่มีสภาพเสยีหายทางกลและรอยไหม้ FAIL PASS หน้าสมัผัสหลัก ต้องไม่มีสภาพสกึหรอรอยไหม้และรอยออกไซด์ FAIL PASS กลไกทางกล ต้องไม่มีสิ่งแปลกปลอมไปขัดกลไกท างาน FAIL PASS ปลดฟิวส์control ปลดสายตัวน าประธานออกจากหม้อแปลงไฟฟ้า ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar แจ้งทีม maintenance TR- MDB. ก่อนทดสอบ Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - a : MΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - b : MΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - c : MΩ กระแสทดสอบ: 100 A ที่ระยะเวลา 1 นาที A ค่าความต้านทานหน้าสมัผัสCircuit Breaker ควรมีค่าต่ า A - a : µΩ โดยค่าความต้านทานหน้าสมัผัสควรมีค่าใกล้เคียงกัน B - b : µΩ ทั้งสามเฟสหากค่าความต้านทานหน้าสมัผัสมีผลต่าง C - c : µΩ เกินกว่า 50% ให้ท าการตรวจสอบเบื้องต้นและเฝ้าระวังต่อไป Responsibility Signature Name Date 85.80 Witnessed by 114.80 มาตรฐาน: - ค่าความต้านทานหน้าสมัผัสมีค่าต่างกันเกินกว่า 50 % เห็นควรให้เฝ้าระวังและตรวจสอบโดยละเอียดอีกครั้ง 3 ที่ มาตรฐาน : 100 ที่ระยะเวลา 1 นาที การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN CIRCUIT BREAKER GENERAL INFORMATION CHECKLIST โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ บ้านพักรับรอง Schneider Electric NS1000N 1000 18 March 2023 Tested by 5 4 - พบซากหนูตายบริเวณเฟสB ของ Main Circuit Breaker COMMENTS AND RECOMMENDATION : - ควรลดขนาดปรับตั้งของเมนเบรกเกอร์ให้สมัพันธ์กับค่ากระแสสงูสดุของหม้อแปลงไฟฟ้า (Rated current LV : 721.69 A) 1000 ที่ระยะเวลา 1 นาที 138.00 118.00 169.00 50.40 นายพนภัทร ฐานานุกูล 18 March 2023 นายณวราชนยุทธ รายละเอียด ผลการทดสอบ หมายเหตุ CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT INSULATION RESISTANCE MEASUREMENT จุดที่ตรวจสอบ ผลตรวจสอบ ค่าต่างกันเกิน50 % VISUAL INSPECTION รายละเอียด INSULATION RESISTANCE MEASUREMENT 6 1 2 PAGE 65


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS ปลดฟิวส์control Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แจ้งทีม maintenance MDB. ก่อนทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - (G,B,C) : MΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - (G,A,C) : MΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - (G,A,B) : MΩ Responsibility Signature Name Date เห็นควรให้เปลี่ยนเป็นชนิดเซรามิคหรืออีพ็อกซี่พร้อมติดตั้ง Heater และพัดลมระบายอากาศภายในตู้MDB เนื่องจากมีปริมาณความชื้นสงู VISUAL INSPECTION ที่จุดที่ตรวจสอบ รายละเอียด ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย COMMENTS AND RECOMMENDATION : ค่าความต้านทานฉนวนของบัสบาร์มีค่าต่ ากว่าเกณฑ์มาตรฐานเห็นควรให้เฝ้าระวังและตรวจสอบโดยละเอียดอีกครั้ง จากการตรวจสอบเบื้องต้นพบหยดน้ าบริเวณ Busbar Support 129.00 103.00 109.00 มาตรฐาน : 4 จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า 1 CHECKLIST รายละเอียด ผลการทดสอบ หมายเหตุ 18 March 2023 18 March 2023 Tested by Witnessed by นายพนภัทร ฐานานุกูล นายณวราชนยุทธ การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN BUSBAR GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ บ้านพักรับรอง ผลตรวจสอบ INSULATION RESISTANCE MEASUREMENT 1000 ที่ระยะเวลา 1 นาที 5 จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง 6 Bus bar ต้องไม่มีรอยไหม้โค้งและโก่งงอ 7 ตัวยึดฉนวน ต้องไม่มีรอยร้าวและรอยแตกไหม้ 3 จุดเข้าสาย CB. ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย 2 จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย PAGE 66


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา Tested by Witnessed by Priority RECOMMENDED ACTION 4.30 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 4.80 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 4.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 31.20 Priority RECOMMENDED ACTION FALSE FALSE FALSE FALSE FALSE 26.90 NORMAL 26.30 NORMAL FALSE 26.40 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE TECHNICAL DATA IR Thermograms Visible Light Image IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 15.00-16.00 50% Precise - - 8.95 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารบ้านพักรับรอง INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 500kVA 0.95 Surge Arrester GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED PAGE 67


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา Tested by Witnessed by Priority RECOMMENDED ACTION 0.50 - ระบบเป็นปกติ 0.60 - ระบบเป็นปกติ 0.90 - ระบบเป็นปกติ (P0) 36.00 Priority RECOMMENDED ACTION FALSE FALSE FALSE FALSE FALSE 35.50 NORMAL 35.10 NORMAL FALSE 35.40 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE TECHNICAL DATA IR Thermograms Visible Light Image IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 15.00-16.00 50% Precise - - 5.91 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารบ้านพักรับรอง INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 500kVA อาคารบ้านพักรับรอง 0.95 Drop Out Fuse GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED PAGE 68


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา 1.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 1.60 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.70 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.60 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 3.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.80 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.40 - ระบบเป็นปกติ (P0) 34.00 Priority RECOMMENDED ACTION FALSE - - FALSE 32.30 NORMAL FALSE 32.40 NORMAL FALSE 32.00 NORMAL FALSE 30.80 NORMAL 33.60 NORMAL FALSE 31.20 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE TECHNICAL DATA IR Thermograms Visible Light Image IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 15.00-16.00 50% Precise - - 13.54 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารบ้านพักรับรอง INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 500kVA 0.95 CT,PT GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED PAGE 69


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา Tested by Witnessed by Priority RECOMMENDED ACTION 2.30 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 3.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 41.90 Priority RECOMMENDED ACTION FALSE FALSE FALSE FALSE FALSE 39.60 NORMAL 38.50 NORMAL FALSE 39.80 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE TECHNICAL DATA IR Thermograms Visible Light Image IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 15.00-16.00 50% Precise - - 2.27 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารบ้านพักรับรอง INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 500kVA 0.95 บุชชิ่งแรงสงูหม้อแปลง GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED PAGE 70


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 7 March 2566 7 March 2566 บัณฑิตอินทา บัณฑิตอินทา Tested by Witnessed by Priority RECOMMENDED ACTION 1.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.00 - ระบบเป็นปกติ 0.80 - ระบบเป็นปกติ 2.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 37.90 Priority RECOMMENDED ACTION FALSE FALSE FALSE FALSE 36.90 NORMAL FALSE 37.90 NORMAL 40.30 NORMAL FALSE 38.70 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE TECHNICAL DATA IR Thermograms Visible Light Image IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 7 March 2566 - 15.00-16.00 50% Precise - - 2.25 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ อาคารบ้านพักรับรอง INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 500kVA 0.95 บุชชิ่งแรงต่ าหม้อแปลง GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED PAGE 71


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 0.10 - ระบบเป็นปกติ 0.20 - ระบบเป็นปกติ โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ Priority RECOMMENDED ACTION 0.10 - ระบบเป็นปกติ (P0) 23.20 0.95 Main Circuit Breaker 1000A IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 50% Schneider Compact - - 1.34 การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED GENERAL INFORMATION อาคารบ้านพักรับรอง INSPECTION DETAIL FLUKE Ti480P S/N 18100128 MDB 230 / 400 25.00 1000 7 March 2566 - 15.00-16.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE 23.60 NORMAL FALSE 23.90 NORMAL FALSE 23.60 NORMAL FALSE 23.70 NORMAL FALSE 24.00 NORMAL FALSE 23.80 NORMAL FALSE - - Priority RECOMMENDED ACTION - ระบบเป็นปกติ 0.40 - ระบบเป็นปกติ 0.70 - ระบบเป็นปกติ 0.40 - ระบบเป็นปกติ 7 March 2566 7 March 2566 Tested by Witnessed by บัณฑิตอินทา บัณฑิตอินทา 0.50 - ระบบเป็นปกติ 0.80 - ระบบเป็นปกติ 0.60 PAGE 72


F I E L D I N S P E C T I O N T E S T R E C O R D DOITUNG ROYAL VILLA ห อ แ ร ง บั น ด า ล ใ จ PAGE 73


Customer : Location : Distribution Transfromer : Phase Sealed type Conservator type Dry type VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS EARTHING RESISTANCE MEASUREMENT FAIL PASS PASS with condition HV to GND : GΩ LV to GND : GΩ HV to LV : GΩ Note : Should be more than 1 GΩ or 1000 MΩ High voltage TR. : Ω Low voltage TR. : Ω Low voltage MDB. : Ω Generator : Ω Note : Should be less than 5 Ω, or 5- 25 Ω with condition Responsibility Signature Name Date - - COMMENTS AND RECOMMENDATION : INSULATION RESISTANCE MEASUREMENT EARTHING RESISTANCE MEASUREMENT 2.78 1.68 3.27 1000 500 1000 Test Voltage (Vdc) COMMENTS AND RECOMMENDATION : Grounding Resistance 4.00 การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD TRANSFORMER AND GROUNDING GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแรงบันดาลใจ 25 March 2023 25 March 2023 3 Tested by Witnessed by การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย VISUAL INSPECTION TECHNICAL DATA Rated current HV Rated current LV Oil Temperature rise Winding Temperature rise Max ambient temperature Impedance voltage Oil Quantity Untank mass Total mass PEA No. Manufacture Year of manufacture Rated Frequency Vector Group Symbol CHECKLIST Rated voltage HV Rated voltage LV Hz kVA V V Serial No. Tap Position K °C °C % Litre kg kg 10.5 Dehydrating breather (Silica gel) 557.35 4510241 3 TIRA THAI 2002 50 Dyn 11 400 ONAN 22000 400 / 230 A A 65 60 40 4.19 320 1,065 1,935 45-111912 Rated Power Type of cooling LV Terminal Oil Level Indicator Oil drain value check Thermometer Buchholz Relay Pressure- Relief Device High voltage fuse Low voltage fuse Tank and Fin HV Bushing and Gasket LV Bushing and Gasket Cover Gasket Tap Changer Gasket HV Terminal เปลี่ยนSilica Gel Capacitor Bank PAGE 74


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS Manufacture : Type : Sizing / Bundle : Wiring method : Length : Rated current : Rated voltage : Connected with : ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า FAIL PASS จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง FAIL PASS ปลดฟิวส์control ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายcontrol ออกจากสายตัวน าประธาน เชื่อมต่อสายที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าประธานออกจาก Main Circuit Breaker แจ้งทีม maintenance หม้อแปลงก่อนเริ่มทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันที่สายไฟ A - (G,B,C) : GΩ ที่ทดสอบเทียบกับสายอื่นต่อลงดินค่าความต้านทานฉนวน B - (G,A,C) : GΩ ต้องมากกว่า 1 MΩ หรือ0.001 GΩ C - (G,A,B) : GΩ Responsibility Signature Name Date THAI YAZAKI NYY 4x185 Sq.mm. / 2 Bundle underground 200 m. 25 March 2023 25 March 2023 GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแรงบันดาลใจ รายละเอียด ผลการทดสอบ หมายเหตุ CHECKLIST TECHNICAL DATA ผลตรวจสอบ 1000 Tested by Witnessed by นายพนภัทรฐานานุกูล นายณวรา ชนยุทธ COMMENTS AND RECOMMENDATION : 2.40 2.42 2.62 ที่ระยะเวลา 1 นาทีมาตรฐาน : การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN FEEDER 606 A. INSULATION RESISTANCE MEASUREMENT 5 ที่ 1 2 3 4 450 / 750 V TR 400 kVA to Main CB 800 AT. รายละเอียด VISUAL INSPECTION จุดที่ตรวจสอบ PAGE 75


Customer : Location : Circuit Breaker Manufacture : Series : Breaking Capacity : AT. VISUAL INSPECTION FAIL PASS FAIL PASS CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT FAIL PASS Main CB. สามารถ Operate ON-OFF ได้ FAIL PASS Main CB. สามารถทดสอบ TRIP-TRIP FREE ได้ FAIL PASS Aux. CB. ทดสอบปลดวงจรจากshunt trip/under, voltage release FAIL PASS ช่องดับอาร์ก ต้องไม่มีสภาพเสยีหายทางกลและรอยไหม้ FAIL PASS หน้าสมัผัสหลัก ต้องไม่มีสภาพสกึหรอรอยไหม้และรอยออกไซด์ FAIL PASS กลไกทางกล ต้องไม่มีสิ่งแปลกปลอมไปขัดกลไกท างาน FAIL PASS ปลดฟิวส์control ปลดสายตัวน าประธานออกจากหม้อแปลงไฟฟ้า ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar แจ้งทีม maintenance TR- MDB. ก่อนทดสอบ Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - a : GΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - b : GΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - c : GΩ กระแสทดสอบ: 100 A ที่ระยะเวลา 1 นาที A ค่าความต้านทานหน้าสมัผัสCircuit Breaker ควรมีค่าต่ า A - a : µΩ โดยค่าความต้านทานหน้าสมัผัสควรมีค่าใกล้เคียงกัน B - b : µΩ ทั้งสามเฟสหากค่าความต้านทานหน้าสมัผัสมีผลต่าง C - c : µΩ เกินกว่า 50% ให้ท าการตรวจสอบเบื้องต้นและเฝ้าระวังต่อไป Responsibility Signature Name Date COMMENTS AND RECOMMENDATION : ควรลดขนาดปรับตั้งของเมนเบรกเกอร์ให้สมัพันธ์กับขนาดพิกัดของสายตัวน าประธานและค่ากระแสสงูสดุของหม้อแปลงไฟฟ้า (Rated current LV : 557.35 A) 1000 ที่ระยะเวลา 1 นาที 17.50 21.00 20.00 มาตรฐาน : 100 ที่ระยะเวลา 1 นาที 65.70 78.20 75.80 มาตรฐาน: หมายเหตุ CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT INSULATION RESISTANCE MEASUREMENT จุดที่ตรวจสอบ ผลตรวจสอบ VISUAL INSPECTION ที่รายละเอียด INSULATION RESISTANCE MEASUREMENT 6 1 25 March 2023 Tested by Witnessed by นายพนภัทรฐานานุกูล 25 March 2023 นายณวรา ชนยุทธ 2 3 5 4 การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN CIRCUIT BREAKER GENERAL INFORMATION CHECKLIST โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแรงบันดาลใจ ABB SACE S6N 800 รายละเอียด ผลการทดสอบ PAGE 76


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS ปลดฟิวส์control Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แจ้งทีม maintenance MDB. ก่อนทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - (G,B,C) : GΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - (G,A,C) : GΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - (G,A,B) : GΩ Responsibility Signature Name Date มาตรฐาน : 4 จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า 1 ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย 2 จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย COMMENTS AND RECOMMENDATION : 11.50 11.50 9.90 หอแรงบันดาลใจ ผลตรวจสอบ INSULATION RESISTANCE MEASUREMENT 1000 ที่ระยะเวลา 1 นาที 5 จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง 6 Bus bar ต้องไม่มีรอยไหม้โค้งและโก่งงอ 7 ตัวยึดฉนวน ต้องไม่มีรอยร้าวและรอยแตกไหม้ 3 จุดเข้าสาย CB. การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN BUSBAR GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ 25 March 2023 25 March 2023 Tested by Witnessed by นายพนภัทรฐานานุกูล นายณวรา ชนยุทธ CHECKLIST รายละเอียด ผลการทดสอบ หมายเหตุ VISUAL INSPECTION ที่จุดที่ตรวจสอบ รายละเอียด ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย PAGE 77


Customer : Location : VISUAL INSPECTION FAIL PASS FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS : : : : : : : : : : : : : : : : : : สภาพตัวถังC ไม่มีรอยบุบบวมรอยไหม้ FAIL PASS สภาพตัวถังC ไม่มีการ over pressure ด้านบนของตัวถัง FAIL PASS จุดต่ออุปกรณ์ไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดต่อที่ terminal C ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดต่อที่ terminal C มีการติดตั้ง discharge Resistor ตามผู้ผลิตแนะน า FAIL PASS Magnetic contactor สามารถตัด-ต่อวงจรได้หน้าสมัผัสต้องไม่อาร์กติดหรือไหม้ FAIL PASS Responsibility Signature Name Date รุ่น พิกัดกระแส VISUAL INSPECTION ที่จุดที่ตรวจสอบ รุ่น Serial No. ผลตรวจสอบ SACE53 250 AT 2 3 4 5 6 COMMENTS AND RECOMMENDATION : การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD CAPACITOR BANK GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแรงบันดาลใจ CAPACITANCE MEASUREMENT 01/02 CHECKLIST รายละเอียด ผลการทดสอบ หมายเหตุ TECHNICAL DATA ผลิตภัณฑ์ Tested by Witnessed by Conection พิกัดแรงดัน รุ่น Number of step kVAR 25 March 2023 Power factor controller Capacitor 25 March 2023 นายพนภัทรฐานานุกูล นายณวรา ชนยุทธ ผลิตภัณฑ์ รุ่น 1 ผลิตภัณฑ์ รายละเอียด รุ่น พิกัดกระแส Circuit Breaker ผลิตภัณฑ์ V Fuse Magnetic Contactor 25 / 27 kVAR พิกัดกระแส ผลิตภัณฑ์ A A ABB RVC 30128 ABB UA50 100 ABB NH00 63 ABB ABB CLMD43 400 / 415 Delta 5 PAGE 78


Customer : Location : 1 2 3 4 5 6 7 8 9 10 11 12 V - µF Responsibility Signature Name Date A-B B-C C-A ph-ph kVAR PASS ค่าความจุของCapacitor ขนาด FAIL Step FAIL PASS Capacitance PASS 260.00 259.00 259.00 258.00 Capacitance (MicroFarad) FUSE ค่าทดสอบ ค่ามาตรฐาน Magnetic Contactor สายตัวน าส าหรับ Capacitor GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแรงบันดาลใจ FIELD INSPECTION AND TEST RECORD CAPACITOR BANK CAPACITANCE MEASUREMENT การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) Tested by Witnessed by นายพนภัทรฐานานุกูล นายณวรา ชนยุทธ 25 March 2023 25 March 2023 FAIL 02/02 260.00 259.00 259.00 258.00 PASS FAIL 258.00 258.00 25.00 ค่าความ ต้านทานฉนวน (GΩ) 258.00 260.00 259.00 258.00 258.00 248.68 248.68 248.68 248.68 248.68 25.00 25.00 25.00 25.00 7.40 8.20 8.10 6.60 6.40 25 kVAR พิกัดแรงดัน 400.00 ควรมีค่าอยู่ระหว่าง 236.25 273.55 COMMENTS AND RECOMMENDATION : PAGE 79


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 17..95 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 เสาต้นCT,PT 0.95 Drop Out Fuse IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 31.70 NORMAL 34.50 NORMAL FALSE 31.80 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 3.30 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 31.20 0.50 - ระบบเป็นปกติ 0.60 - ระบบเป็นปกติ Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 80


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 14.14 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 เสาต้นCT,PT 0.95 Surge Arrester IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 25.50 NORMAL 27.90 NORMAL FALSE 24.80 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 0.10 - ระบบเป็นปกติ (P0) 28.00 2.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 3.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 81


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 14.14 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 เสาต้นCT,PT 0.95 CT,PT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 31.30 NORMAL 32.80 NORMAL FALSE 29.40 NORMAL FALSE FALSE 35.40 NORMAL Priority RECOMMENDED ACTION FALSE FALSE 1.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 31.30 0.00 - ระบบเป็นปกติ 1.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 4.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 82


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 13.28 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 เสาต้นหม้อแปลง 400kVA 0.95 Drop Out Fuse IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 31.30 NORMAL 33.30 NORMAL FALSE 33.80 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 3.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 29.40 1.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 4.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 83


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 9.50 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 400kVA 0.95 Surge Arrester IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 34.60 NORMAL 34.70 NORMAL FALSE 34.40 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 2.30 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 32.40 2.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 84


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% TIRA THAI - - 10.89 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 400kVA 0.95 บุชชิ่งแรงสงู IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 40.00 NORMAL 39.80 NORMAL FALSE 40.00 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 1.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 37.90 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 85


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 14.14 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 400kVA 0.95 บุชชิ่งแรงต่ า IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 0 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 33.00 NORMAL 33.60 NORMAL FALSE 36.20 NORMAL FALSE FALSE 34.70 NORMAL Priority RECOMMENDED ACTION FALSE FALSE 0.80 - ระบบเป็นปกติ (P0) 34.40 1.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 1.80 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.30 - ระบบเป็นปกติ Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 86


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date 8 March 2566 8 March 2566 Tested by Witnessed by บัณฑิตอินทา บัณฑิตอินทา 2.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.60 - ระบบเป็นปกติ 0.70 - ระบบเป็นปกติ 0.40 - ระบบเป็นปกติ FALSE 29.00 NORMAL FALSE - - Priority RECOMMENDED ACTION FALSE 26.90 NORMAL FALSE 28.70 NORMAL FALSE 28.60 NORMAL Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE 27.10 NORMAL FALSE 27.20 NORMAL 230 / 400 25.00 800 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED GENERAL INFORMATION หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 MDB 1.40 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ Priority RECOMMENDED ACTION 1.60 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 26.50 0.95 Main Circuit Breaker 800AT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 50% ABB SACE S6 - - 0.90 PAGE 87


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% ABB SACE S1 - - 0.59 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 LP7 หอแห่งแรงบันดาลใจ 0.95 Circuit Breaker 125AT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 125 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 26.60 NORMAL 27.60 NORMAL FALSE 28.10 NORMAL FALSE 26.30 NORMAL FALSE 26.90 NORMAL Priority RECOMMENDED ACTION FALSE - - FALSE 26.20 NORMAL 2.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 25.60 1.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 2.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.60 - ระบบเป็นปกติ 1.30 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 0.70 - ระบบเป็นปกติ 0.40 - ระบบเป็นปกติ Tested by Witnessed by Priority RECOMMENDED ACTION 0.70 - ระบบเป็นปกติ 1.80 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 88


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% Schneider - - 0.53 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ หอแห่งแรงบันดาลใจ INSPECTION DETAIL FLUKE Ti480P S/N 18100128 ตู้AC BOX (F2) 0.95 Circuit Breaker 50AT IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 50 8 March 2566 - 10.00-11.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 31.80 NORMAL 32.50 NORMAL FALSE 32.30 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 4.70 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 27.80 4.00 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 4.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 89


F I E L D I N S P E C T I O N T E S T R E C O R D DOITUNG ROYAL VILLA โ ร ง ง า น แ ม ค ค า แ ล ะ น้ า ดื่ ม PAGE 90


Customer : Location : Distribution Transfromer : Phase Sealed type Conservator type Dry type VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS EARTHING RESISTANCE MEASUREMENT FAIL PASS PASS with condition HV to GND : GΩ LV to GND : GΩ HV to LV : GΩ Note : Should be more than 1 GΩ or 1000 MΩ High voltage TR. : Ω Low voltage TR. : Ω Low voltage MDB. : Ω Generator : Ω Note : Should be less than 5 Ω, or 5- 25 Ω with condition Responsibility Signature Name Date Capacitor Bank LV Terminal Oil Level Indicator Oil drain value check Thermometer Buchholz Relay Pressure- Relief Device High voltage fuse Low voltage fuse Tank and Fin HV Bushing and Gasket LV Bushing and Gasket Cover Gasket Tap Changer Gasket HV Terminal Dehydrating breather (Silica gel) 144.34 480001 3 PHONG PIMARN 2005 50 Dyn 11 100 ONAN 22000 400 / 230 A A 60 65 40 3.74 180 372 620 48-110020 Rated Power Type of cooling Rated voltage HV Rated voltage LV Hz kVA V V Serial No. Tap Position K K °C % Litre kg kg 2.62 26 March 2023 26 March 2023 3 Tested by Witnessed by การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย การไฟฟ้าสว่นภูมิภาคอ าเภอแม่สาย VISUAL INSPECTION TECHNICAL DATA Rated current HV Rated current LV Oil Temperature rise Winding Temperature rise Max ambient temperature Impedance voltage Oil Quantity Untank mass Total mass PEA No. Manufacture Year of manufacture Rated Frequency Vector Group Symbol CHECKLIST การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD TRANSFORMER AND GROUNDING GENERAL INFORMATION โรงงานแมคคาและน าดื่ม โครงการพัฒนาดอยตุง (พื นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ INSULATION RESISTANCE MEASUREMENT EARTHING RESISTANCE MEASUREMENT 11.00 4.45 12.00 1000 500 1000 Test Voltage (Vdc) COMMENTS AND RECOMMENDATION : Grounding Resistance 3.20 3.00 - COMMENTS AND RECOMMENDATION : PAGE 91


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS Manufacture : Type : Sizing / Bundle : Wiring method : Length : Rated current : Rated voltage : Connected with : ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย FAIL PASS จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า FAIL PASS จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง FAIL PASS ปลดฟิวส์control ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายcontrol ออกจากสายตัวน าประธาน เชื่อมต่อสายที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าประธานออกจาก Main Circuit Breaker แจ้งทีม maintenance หม้อแปลงก่อนเริ่มทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันที่สายไฟ A - (G,B,C) : MΩ ที่ทดสอบเทียบกับสายอื่นต่อลงดินค่าความต้านทานฉนวน B - (G,A,C) : MΩ ต้องมากกว่า 1 MΩ หรือ0.001 GΩ C - (G,A,B) : MΩ Responsibility Signature Name Date การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN FEEDER 238 A. INSULATION RESISTANCE MEASUREMENT 5 ที่ 1 2 3 4 600 / 1000 V. TR. 100 kVA to Main CB 250 AT รายละเอียด VISUAL INSPECTION จุดที่ตรวจสอบ 40.00 30.00 40.00 ที่ระยะเวลา 1 นาทีมาตรฐาน : Witnessed by นายพนภัทร ฐานานุกูล นายณวราชนยุทธ COMMENTS AND RECOMMENDATION : ควรปิดช่องเดินสายหรือช่องเปิดต่างๆ เพื่อป้องกันไม่ให้สตัว์เข้าไปภายในตู้MDB และสร้างความเสยีหายแก่ระบบไฟฟ้า 26 March 2023 26 March 2023 GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ โรงงานแมคคาและน าดื่ม รายละเอียด ผลการทดสอบ หมายเหตุ CHECKLIST TECHNICAL DATA ผลตรวจสอบ 1000 Tested by BANGKOK CABLE CV 4x95 Sq.mm / 1 Bundle IMC 15 m. PAGE 92


Customer : Location : Circuit Breaker Manufacture : Series : Breaking Capacity : AT. VISUAL INSPECTION FAIL PASS FAIL PASS CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT FAIL PASS Main CB. สามารถ Operate ON-OFF ได้ FAIL PASS Main CB. สามารถทดสอบ TRIP-TRIP FREE ได้ FAIL PASS Aux. CB. ทดสอบปลดวงจรจากshunt trip/under, voltage release FAIL PASS ช่องดับอาร์ก ต้องไม่มีสภาพเสยีหายทางกลและรอยไหม้ FAIL PASS หน้าสมัผัสหลัก ต้องไม่มีสภาพสกึหรอรอยไหม้และรอยออกไซด์ FAIL PASS กลไกทางกล ต้องไม่มีสิ่งแปลกปลอมไปขัดกลไกท างาน FAIL PASS ปลดฟิวส์control ปลดสายตัวน าประธานออกจากหม้อแปลงไฟฟ้า ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar แจ้งทีม maintenance TR- MDB. ก่อนทดสอบ Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - a : GΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - b : GΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - c : GΩ กระแสทดสอบ: 100 A ที่ระยะเวลา 1 นาที A ค่าความต้านทานหน้าสมัผัสCircuit Breaker ควรมีค่าต่ า A - a : µΩ โดยค่าความต้านทานหน้าสมัผัสควรมีค่าใกล้เคียงกัน B - b : µΩ ทั งสามเฟสหากค่าความต้านทานหน้าสมัผัสมีผลต่าง C - c : µΩ เกินกว่า 50% ให้ท าการตรวจสอบเบื องต้นและเฝ้าระวังต่อไป Responsibility Signature Name Date 523.00 Witnessed by 699.00 มาตรฐาน: 3 ที่ มาตรฐาน : 100 ที่ระยะเวลา 1 นาที การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN CIRCUIT BREAKER GENERAL INFORMATION CHECKLIST โครงการพัฒนาดอยตุง (พื นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ โรงงานแมคคาและน าดื่ม Schneider Electric NSX 250F 250 26 March 2023 Tested by 5 4 COMMENTS AND RECOMMENDATION : ควรลดขนาดปรับตั งของเมนเบรกเกอร์ให้สมัพันธ์กับขนาดพิกัดของสายตัวน าประธานและค่ากระแสสงูสดุของหม้อแปลงไฟฟ้า (Rated current LV : 144.34 A) 1000 ที่ระยะเวลา 1 นาที MCB: 200 ATS: 45 MCB: 200 ATS: 45 MCB: 200 ATS: 50 444.00 นายพนภัทร ฐานานุกูล 26 March 2023 นายณวราชนยุทธ รายละเอียด ผลการทดสอบ หมายเหตุ CIRCUIT BREAKER CONTACT RESISTANCE MEASUREMENT INSULATION RESISTANCE MEASUREMENT จุดที่ตรวจสอบ ผลตรวจสอบ VISUAL INSPECTION รายละเอียด INSULATION RESISTANCE MEASUREMENT 6 1 2 PAGE 93


Customer : Location : VISUAL INSPECTION FAIL PASS INSULATION RESISTANCE MEASUREMENT FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS FAIL PASS ปลดฟิวส์control Main CB. สภาวะต าแหน่งเปิดวงจร (OFF) ปลดสายControl บางวงจรออกจากBusbar ปลดกับดักฟ้าผ่าออกจากระบบ ปลดสายตัวน าสายป้อนบางวงจรออกจากBus bar เชื่อมต่อBus bar ที่ไม่ได้ทดสอบลงดิน Branch CB. สภาวะต าแหน่งเปิดวงจร (OFF) แจ้งทีม maintenance MDB. ก่อนทดสอบ แรงดันทดสอบ: Vdc. ค่าความต้านทานฉนวนทดสอบโดยจ่ายแรงดันให้อุปกรณ์ A - (G,B,C) : GΩ ที่ทดสอบระหว่างด้านSource และด้านLoad ค่าความ B - (G,A,C) : GΩ ต้านทานฉนวนต้องมากกว่า 100 MΩหรือ0.1 GΩ C - (G,A,B) : GΩ Responsibility Signature Name Date VISUAL INSPECTION ที่จุดที่ตรวจสอบ รายละเอียด ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย COMMENTS AND RECOMMENDATION : 200.00 200.00 150.00 มาตรฐาน : 4 จุดเข้าสาย CB. ต้องใช้cable lug ขนาดเหมาะสมกับสายไฟฟ้า 1 CHECKLIST รายละเอียด ผลการทดสอบ หมายเหตุ 26 March 2023 26 March 2023 Tested by Witnessed by นายพนภัทร ฐานานุกูล นายณวราชนยุทธ การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) FIELD INSPECTION AND TEST RECORD MAIN BUSBAR GENERAL INFORMATION โครงการพัฒนาดอยตุง (พื นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ โรงงานแมคคาและน าดื่ม ผลตรวจสอบ INSULATION RESISTANCE MEASUREMENT 1000 ที่ระยะเวลา 1 นาที 5 จุดเข้าสาย CB. ต้องกวดขันแน่นและเชื่อมต่อสายด้วยวิธีที่ถูกต้อง 6 Bus bar ต้องไม่มีรอยไหม้โค้งและโก่งงอ 7 ตัวยึดฉนวน ต้องไม่มีรอยร้าวและรอยแตกไหม้ 3 จุดเข้าสาย CB. ฉนวนสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย 2 จุดต่อสายไฟฟ้า ต้องไม่มีลักษณะเสยีหายทางกายภาพและการหลอมละลาย PAGE 94


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% - - - 8.26 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ โรงงานแมคคาและน้ าดื่ม INSPECTION DETAIL FLUKE Ti480P S/N 18100128 ต้นหม้อแปลง100 kVA 0.95 Drop Out Fuse IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 8 March 2566 - 11.00-12.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 31.40 NORMAL 28.70 NORMAL FALSE 31.00 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 1.20 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง (P0) 27.50 3.90 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง 3.50 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 95


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : kV Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% PHONG PIMARN - - 10.16 22 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ โรงงานแมคคาและน้ าดื่ม INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 100 kVA 0.95 บุชชิ่งแรงสงู IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 8 March 2566 - 11.00-12.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 34.40 NORMAL 34.20 NORMAL FALSE 32.60 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 0.50 - ระบบเป็นปกติ (P0) 33.70 0.70 - ระบบเป็นปกติ 1.10 4 ตรวจหาสาเหตุที่อาจเป็นไปได้อีกครั้ง Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 96


Customer : Location : Infrared Thermography : Installation : Emissivity : Equipment ID : Relative humidity : Manufacture : Wind speed : m/s Series : Distance : m Rated voltage : V Environment Temperature : °C Rated current : A Inspection Date : Feeder : Inspection Time : Component Information Actual Temp (A0) 0 : °C Actual Temp (A1) 0 : °C Actual Temp (A2) 0 : °C Actual Temp (A3) 0 : °C Actual Temp (A4) 0 : °C Actual Temp (A5) 0 : °C Actual Temp (A6) 0 : °C Delta T over ambient air temperature Reference Temperature : °C Different Temperature (Ref. - A0) : °C Different Temperature (Ref. - A1) : °C Different Temperature (Ref. - A2) : °C Different Temperature (Ref. - A3) : °C Different Temperature (Ref. - A4) : °C Different Temperature (Ref. - A5) : °C Delta T between similar components under similar load Different Temperature (A0 - A3) : °C Different Temperature (A1 - A4) : °C Different Temperature (A2 - A5) : °C Responsibility Signature Name Date GENERAL INFORMATION การไฟฟ้าส่วนภูมิภาค(PROVINCIAL ELECTRICITY AUTHORITY ) INFRARED INSPECTION REPORT INFRARED 50% PHONG PIMARN - - 10.72 230 / 400 โครงการพัฒนาดอยตุง (พื้นที่ทรงงาน)อันเนื่องมาจากพระราชด าริ โรงงานแมคคาและน้ าดื่ม INSPECTION DETAIL FLUKE Ti480P S/N 18100128 หม้อแปลง 100 kVA 0.95 บุชชิ่งแรงต่ า IR THERMOGRAMS AND VISIBLE LIGHT IMAGES 25.00 - 8 March 2566 - 11.00-12.00 IR Thermograms Visible Light Image TECHNICAL DATA Ref. Temp Temperature Value COMMENTS AND RECOMMENDATION FALSE FALSE 30.80 NORMAL FALSE 31.00 NORMAL FALSE FALSE Priority RECOMMENDED ACTION FALSE FALSE 0.70 - ระบบเป็นปกติ (P0) 31.50 0.50 - ระบบเป็นปกติ Tested by Witnessed by Priority RECOMMENDED ACTION 8 March 2566 8 March 2566 บัณฑิตอินทา บัณฑิตอินทา PAGE 97