Safety Made Simple™
Testers For Electrical Safety Compliance
Hipot • Ground Bond • Insulation Resistance • Line Leakage • Multi-Function Electrical Safety
PRODUCT SELECTION GUIDE
We’ve been keeping our customers happy for more than 60 years by focusing on the little things.
During that time we’ve learned a lot about what it takes to stay current, relevant and ahead of the
competition. Our products are packed with only the features you need, and none that you don’t.
Explore the most intuitive testers on the market.
6000 SERIES • • • 30A • • •
6330
4000 SERIES
• • • 30A • •
4520 • • • 30A •
4320
290 SERIES
298 • • • •
297 • • • • •
296 • • • •
295 • • •
294 • • •
260 SERIES
264 40A •
266 60A •
2200 SERIES
2205 •
2 hipot.com
SAFETY MADE SIMPLE®
PROVEN RELIABILITY
Every Slaughter tester is backed by a standard 1-year warranty. Extend your warranty for up to
3 years when you return your tester to us for annual calibration and inspection. We also offer
2-year and 3-year buyer protection plans which you can purchase upfront without calibration
requirement.
ONGOING SUPPORT
With over 60 years of industry experience, Slaughter has developed the best support team in the industry.
Our technical library includes resources to help you learn more about your Slaughter tester, NRTL standards,
and safety compliance.
1-DAY SHIPMENT GUARANTEE*
We understand that you need to receive your tester in a timely fashion in order to prevent downtime
on the production line. We ship every order within 1 business day.
*On all standard products. If your product ships late, we pay the freight.
CUSTOMER EXPERIENCE GUARANTEE
We are so confident our instruments will meet your needs that we provide a 100% experience
guarantee. If for any reason you are dissatisfied with your Slaughter tester, return it for a full refund
or exchange within 45 days of the original purchase date, no questions asked.
50Hz 60Hz
6000 SERIES
• • • • • • • • 6330
4000 SERIES
• • • • • • OPT • 4520
• • • • • • OPT • 4320
290 SERIES
• • • • • • •
OPT OPT 298
• • • • • • •
OPT OPT 297
• • • • • • •
OPT OPT 296
• • • • • • •
OPT OPT 295
• • • • • •
OPT OPT 294
260 SERIES
• • •
OPT OPT 264
• • •
OPT OPT 266
2200 SERIES
• • 2205
Toll Free 800-504-0055 Phone +1-847-932-3662 3
6000 SERIES
6-IN-1 ELECTRICAL
SAFETY TESTERS
FPOSee how
simple using
our tester
can be!
VERSATILE 6-IN-1 The 6330 is our most advanced multi-function
FUNCTIONALITY electrical safety tester with 6-in-1 test capability.
10 PROGRAMMABLE Our flagship model is designed to make advanced
MEMORIES WITH 20 TEST testing applications simple with the most intuitive
STEPS EACH user interface on the market. With minimal setup
INTUITIVE USER INTERFACE time, you can perform AC Hipot, DC Hipot, Ground
4 BUILT-IN Bond, Insulation Resistance, Functional Run and
NRTL-COMPLIANT Line Leakage tests on a variety of DUT’s. The 6330
MEASURING DEVICES maximizes production line throughput far beyond
AUTOMATE WITH PLC a single function tester, while taking up less space.
CONTROL OR OPTIONAL Use the 6330 from the front panel or automate your
RS-232 INTERFACE testing via the optional RS-232 interface.
REMOTE SAFETY
INTERLOCK 30A
EN 61010-1 •6300 • • • • •
EN 61010-31
hipot.com
4
SAFETY MADE SIMPLE®
6000 SERIES SPECS FOUND ON PAGE 19
RELEVANT APPLICATIONS SERIES FEATURES
MEDICAL 50Hz 60Hz
APPLIANCE
INFORMATION TECHNOLOGY
SUPPLIED ACCESSORIES
102-055-913 High Voltage Lead 6 ft. (1.8m)
102-013-001 Input Power Cable USA
99-10457-01 40 Amp High Current Return Lead 10 ft. (3m)
99-10468-01 40 Amp High Current Lead 10 ft. (3m)
99-10009-01 30 Amp High Current Return Lead 6 ft. (1.8m)
99-10008-01 30 Amp High Current Lead 6 ft. (1.8m)
99-10469-01 Black DUT Input Line Test Lead
99-10470-01 Black DUT Input Neutral Test Lead
99-10471-01 White DUT Output Line Test Lead
99-10472-01 White DUT Output Neutral Test Lead
99-10040-01 Interlock Connector
99-10467-01 Adapter Box Universal US 10 ft. (3m)
99-10106-01 Fuse
Toll Free 800-504-0055 Phone +1-847-932-3662 5
4000 SERIES
4-IN-1 ELECTRICAL
SAFETY TESTERS
FPOSee how
simple using
our tester
can be!
VERSATILE 4-IN-1 The 4000 Series provides advanced 4-in-1 test
FUNCTIONALITY capability in a convenient one-box solution. Our
most popular multi-function tester, the 4000 Series
INTUITIVE USER INTERFACE performs AC Hipot, DC Hipot, Insulation Resistance
and Ground Bond tests while taking up minimal
MEETS 200 MA SHORT production line space. The 4000 Series includes the
CIRCUIT REQUIREMENTS most intuitive menu system in the industry, reducing
setup time and increasing production line throughput
6 PROGRAMMABLE for any application. With multiple memories and an
MEMORIES WITH 6 TEST optional RS-232 interface, you can quickly perform
STEPS EACH tests on a variety of DUT’s from the front panel or
with a PLC remote. Choose from two models.
AUTOMATE WITH PLC
CONTROL OR OPTIONAL 30A
RS-232 INTERFACE
4320 •• •• •• •• •
REMOTE SAFETY 4520
INTERLOCK
hipot.com
EN 61010-1
EN 61010-31
Model 4320
6
SAFETY MADE SIMPLE®
4000 SERIES SPECS FOUND ON PAGE 20
RELEVANT APPLICATIONS SERIES FEATURES
APPLIANCE 50Hz 60Hz
CABLE
MOTORS & PUMPS
SUPPLIED ACCESSORIES
102-050-913 High Voltage Retractable Probe 6 ft. (1.8m)
102-055-913 High Voltage Lead 6 ft. (1.8m)
125-013-001 Input Power Cable USA
99-10164-01 Input Power Cable USA
99-10008-01 30 Amp High Current Lead 6 ft. (1.8m)
99-10009-01 30 Amp High Current Return Lead 6 ft. (1.8m)
99-10040-01 Interlock Connector
99-10106-01 Fuse 4320
99-10656-01 Fuse 4520
Toll Free 800-504-0055 Phone +1-847-932-3662 7
290 SERIES
HIPOT
TESTERS
FPOSee how
simple using
our tester
can be!
INTUITIVE USER INTERFACE The 290 Series is our most popular line of Hipot
10 PROGRAMMABLE testers. These testers are designed to simplify every
MEMORIES aspect of safety testing for operators of all comfort
TAMPER PROOF FRONT levels. Our 290 Series includes the most intuitive
PANEL CONTROLS user interface in the industry and won’t take up too
INCLUDES CONTINUITY much space on the production line. With multiple
TEST FUNCTION memories and an optional RS-232 interface, you can
AUTOMATE WITH PLC quickly perform tests on a variety of DUT’s from the
CONTROL OR OPTIONAL front panel or with a PC. Choose from 3 different
RS-232 INTERFACE models to satisfy your testing requirements.
REMOTE SAFETY
INTERLOCK 294 • •
295 • •
EN 61010-1 296 • • •
EN 61010-31 297 • • • •
•298 500VA
8
SAFETY MADE SIMPLE® hipot.com
RELEVANT APPLICATIONS 290 SERIES SPECS FOUND ON PAGE 21
APPLIANCE SERIES FEATURES
LIGHTING & LED TESTING
POWER TOOLS 50Hz 60Hz
MOTORS & PUMPS
SUPPLIED ACCESSORIES
102-069-904 Return Lead 6 ft. (1.8m)
102-055-913 High Voltage Lead 6 ft. (1.8m)
125-013-001 Input Power Cable USA
99-10040-01 Interlock Connector
Toll Free 800-504-0055 Phone +1-847-932-3662 9
260 SERIES
GROUND BOND
TESTERS
FPOSee how
simple using
our tester
can be!
INTUITIVE USER INTERFACE Our 260 Series makes Ground Bond testing
MILLIOHM OFFSET simple. We offer two models so that you can have
FUNCTION FOR ACCURATE a simple and easy-to-use Ground Bond tester that
GROUND BOND TESTING provides the output current you need to satisfy
5 PROGRAMMABLE NRTL specifications. With an intuitive interface that
MEMORIES allows you to set-up a test in seconds and practical
AUTOMATE WITH PLC security settings, our 260 Series can easily be
CONTROL deployed in both laboratory and production line
environments.
40A 60A
264 • •
266
EN 61010-1 hipot.com
EN 61010-31
10
SAFETY MADE SIMPLE®
260 SERIES SPECS FOUND ON PAGE 22
RELEVANT APPLICATIONS SERIES FEATURES
LABORATORY EQUIPMENT 50Hz 60Hz
MEDICAL
APPLIANCE
WATER PUMPS
264 SUPPLIED ACCESSORIES
99-10725-01 40 Amp High Current Lead 6 ft. (1.8m)
99-10724-01 40 Amp High Current Return Lead 6 ft. (1.8m)
125-013-001 Input Power Cable USA
99-10103-01 Fuse
266 SUPPLIED ACCESSORIES
99-10238-01 60 Amp High Current Return Lead 6 ft. (1.8m)
99-10239-01 60 Amp High Current Lead 6 ft. (1.8m)
99-10164-01 Input Power Cable USA
99-10210-01 Fuse
Toll Free 800-504-0055 Phone +1-847-932-3662 11
2200 SERIES
INSULATION
RESISTANCE TESTERS
FPOSee how
simple using
our tester
can be!
PORTABLE DESIGN The 2205 is our stand-alone Insulation Resistance
USER-FRIENDLY INTERFACE tester designed for use on the production line or
AUTOMATE WITH PLC in the field. With measurements up to 200 GΩ at
CONTROL voltages up to 1000 VDC, the 2205 can satisfy even
REMOTE SAFETY the most demanding application requirements.
INTERLOCK We’ve incorporated the most user-friendly interface
in the industry and a portable design for safe and
easy testing.
•2205
12 hipot.com
SAFETY MADE SIMPLE®
2200 SERIES SPECS FOUND ON PAGE 23
RELEVANT APPLICATIONS SERIES FEATURES
MOTORS
SWITCHES AND CONTROLS
CABLE AND HARNESS
AEROSPACE
SUPPLIED ACCESSORIES
102-045-901 Return Clip w/ Black BNC Plug 6 ft. (1.8m)
102-055-913 High Voltage Lead 6 ft.
125-013-001 Input Power Cable USA
99-10040-01 Interlock Connector
99-10258-01 Fuse
Toll Free 800-504-0055 Phone +1-847-932-3662 13
ACCESSORIES
TEST VERIFICATION BOX
TVB-1
The TVB-1 is a go / no-go daily test verification box designed to
ensure that the failure detectors of a Slaughter electrical safety
tester are functioning properly. The TVB-1 was designed to verify
AC and DC Hipot test functionality, making it the ideal solution for
manufacturers who are required to conduct daily verifications on their
test equipment.
TVB-1 Compatible Models: 294, 295, 296, 297, 298
TVB-2 Compatible Models: All models
ADAPTER BOX
99-10001-01
We have several adapter box configurations available to meet the broad needs
of our customers. An adapter box allows for safe and easy testing of line cord-
terminated products. Simply connect the adapter box to the tester and then
plug the DUT into the adapter box. Adapter boxes are available for most test
instruments in multiple country configurations.
Compatible Models: 1340, 2500, 2900
Adapter Box Available Configurations Used With
99-10001-01 Universal Receptacle Box High Voltage 294, 295, 296, 297, 298
99-10005-01 Universal Receptacle Box High Current 264, 4320, 4520
99-10467-01 Universal Receptacle Box HC/HV/LLT 6330
1144 SAFETY MADE SIMPLE® REMOTE TRIGGER TEST/RESET BOX
RTB-1/2
The RTB is a Remote Test and Reset Control Box. It comes in two different
configurations: RTB-01 and RTB-02. Both models utilize the connection of Remote
Input/Output on the back of all compatible Slaughter models. Both RTB-01 and
RTB-02 can be used to initiate and reset a test. The RTB-02 has an additional feature
(LED’s) which allows the operator to monitor the PASS, FAIL and PROCESSING signals.
RTB-01 & RTB-02 Compatible Models: 2 94, 295, 296, 297, 298, 264, 266, 4320, 4520, 6330
hipot.com
DUT ENCLOSURE
99-10599-01
Our DUT Enclosure is designed to protect the operator from
electric shock during testing. Interface the enclosure with our
Remote Safety Interlock feature to automatically disable the
tester's output when the enclosure door is opened.
WOOD BASE DUT ENCLOSURE WITH PLEXIGLASS DOOR
Outside dimensions: (W x D x H) 24" x 19" x 11.5",
610 mm x 483 mm x 293 mm
Inside dimensions: (W x D x H) 20" x 16" x 10",
508 mm x 407 mm x 254 mm
3/4" Walls, 3/4" Flame Retardant Foam,
1/4" Plexiglass cover
Compatible Models: All Hipot Testers w/ Interlock
PLEXIGLASS DUT ENCLOSURE
Dimensions: (W x D xH) 22" x 24" x 8,"
558.8 mm x 601.5mm x 203.2 mm
Compatible Models: All Hipot Testers w/ Interlock
*Also a Safe Workstation accessory
DUAL ACTION TRIGGER
TEST PROBE 10 FT. (3m)
99-10473-01
This high voltage test gun has a dual action test trigger that controls the
retractable probe tip and activates the high voltage output of the tester.
The unique ergonomic shape makes this probe easy and comfortable to use.
Compatible Models: 294, 295, 296, 297, 298, 4320, 4520
*Also a Safe Workstation accessory
40 AMP HIGH CURRENT PROBE Phone +1-847-932-3662 1155
W/ LUG 10 FT. (3m)
99-10661-01
This fixed tip probe allows for easy contact with the grounding
points of the DUT. The probe has two separate test buttons
making it comfortable to use in various positions. The test
switch can be used to activate high current after making good
contact with the test point.
Compatible Models: 264, 4320, 4520, 6330
*Also a Safe Workstation accessory
Toll Free 800-504-0055
SAFE WORKSTATION ACCESSORIES
INSULATION MAT 20 kV
99-10691-01
The electrical insulation mat is an ideal means for adding a level
of operator safety. This mat is formulated to provide electrical
insulation for the operator. Insulating matting prevents the operator
from being grounded thereby preventing electrical shock.
HIGH VOLTAGE WARNING SIGN
99-10690-01
This "DANGER: HIGH VOLTAGE" sign is ideal for warning
unauthorized operators to stay away from the test area. This sign
should be clearly visible and mounted outside of the electrical
testing area.
RED/GREEN SIGNAL REMOTE TRIGGER
TOWER LIGHT FOOTSWITCH
99-10705-01 and 99-10706-01 99-10433-01
Gives an indication as to the Ideal for use in applications
status of the testing area. A where an operator needs
green light indicates the Hipot to perform a test while
tester is not outputting high using test probes.
voltage and the test area is Compatible with all testers
safe. A red light indicates that
the Hipot tester is active and to RETURN
stay clear of the test area. RETRACTABLE
Dual Remote I/O Compatible PROBE 10 FT.
Series: (3m)
260, 290, 4000, 6000
102-064-904
16 Compatible Series:
SAFETY MADE SIMPLE® 294, 295, 296, 297, 298
hipot.com
A E 10’
B
F E-STOP J
C
H 10’
D I
G
Setting up a Safe Workstation Scan the QR
code to learn
One of the best ways to prevent injury is to ensure that the test station is set up more about Safe
safely and securely. Test stations can be setup with or without direct protection Workstation
depending on your requirements. Direct protection means that the operator Packages
cannot physically come into contact with an energized DUT while a test is running.
AEH
DUT Safety Encloser Signal Tower Light Non-Conductive
Work Bench
This is wired to the Hipot tester’s Remote Gives an indication as to the status of
Safety Interlock. This protects you from the testing area. A green light indicates Only use a work bench made of non-
touching the DUT while a test is in progress. the Hipot tester is not outputting high conductive material such as plastic or
If the enclosure door is opened, the tester’s voltage and the test area is safe. A red light wood. This ensures no stray leakage current
high voltage is immediately disabled. indicates that the Hipot tester is active and could flow through you during a test.
to stay clear of the test area.
B I
F
Hipot Tester Dual Remote Palm Switches
Emergency Stop Button
Tests the DUT. Two hand operation switches force the
Located on the perimeter of the test area. operator to place a hand on each switch
C In the event of an emergency, someone and hold them throughout the test.
outside the test area can hit the E-Stop The palm switches should be placed at
Test Operator button to immediately cut off power to the least 21.6" (550mm) apart to prevent the
entire test station. operator from one hand activation of both
D switches.
G
High Voltage Insulation Mat J
Warning Signs
This isolates you from ground which NEC (National Electric
provides an additional means of protection Mark the testing area with clearly posted Code) & NFPA (National Fire
when operating high voltage equipment. signs that read: DANGER-HIGH VOLTAGE
TEST IN PROGRESS. UNAUTHORIZED Protection Agency
PERSONNEL KEEP AWAY.
Stipulate that any unqualified workers
shall not come within 10' of an EXPOSED
energized circuit.
Toll Free 800-504-0055 Phone +1-847-932-3662 17
INDEX
ICONOLOGY
The AC Hipot test The Functional Run Perform a Hipot test
is used to stress test ensures your DUT with confidence by
the insulation of is operating properly ensuring your test
a DUT with AC before shipment. leads are connected
high voltage. correctly.
Ensures you apply the
The DC Hipot test Output up to 100 mA correct output voltage
is used to stress of current during an AC to your DUT with no
the insulation of a Hipot test. guesswork required.
DUT with DC high An external serial bus
voltage. Quickly setup, edit interface standard for
The Insulation and recall test settings connecting peripheral
Resistance test is used for different types of devices to a computer
to determine the total DUT’s with multiple Maximize operator
resistance of a DUT’s user-defined memory safety by connecting
insulation. locations. an enclosure, warning
The Ground lights, or safety
Continuity test is used 50Hz 60Hz Get your products probes to your tester.
to verify the presence ready for the global Increase productivity by
of the DUT’s earth market by testing at 50 connecting your tester
ground conductor. or 60 Hz. to a PC for automated
The Ground Bond applications with
test is used to verify Prevents false failures optional RS-232 control.
the integrity of a by slowly ramping up This tester is NRTL
DUT’s earth ground the output voltage listed and was
conductor. over time – perfect subjected to the
The Line Leakage test for sensitive or highly same rigorous tests
is used to determine capacitive DUT’s. it must perform.
the amount of current Eliminates the need to
that flows through the make adjustments during hipot.com
insulation of a DUT testing by consistently
during operation. applying the correct
voltage for the correct
18 amount of time.
SAFETY MADE SIMPLE®
INDEX
6000 SERIES SPECIFICATIONS
INPUT (294, 295, 296, 297, 298) INSULATION RESISTANCE TEST MODE (297 only)
Voltage 100-120 VAC / 200-240 VAC ± 10% Auto Range Output Voltage Range: 0.1-1.00 kVDC
Frequency 50/60 Hz ± 5% Resolution: 0.01 kV
Accuracy: ± (1.5% of setting + 3 V)
Fuse 3.15 A / 250 VAC Fast-Blow Resistance Display Range: 1 - 1000 MΩ
Resolution: 1 MΩ
Accuracy: 100-499 V ± (7% of setting + 2 MΩ)
500-1000 V ± (3% of setting + 2 MΩ)
DIELECTRIC WITHSTAND TEST MODE
0, 1 - 1000 MΩ
Output Rating 298 AC 0-5.00 kVAC, 99.99 mA Hi-Limit Range: 1 MΩ
Lo-Limit Resolution:
294 DC 0-6.00 kVDC, 5.00 mA 1 - 1000 MΩ (0=off)
296 Range: 1 MΩ
297 Resolution:
Voltage Setting Range: 0-5.00 kVAC Timer Range: 0.2 or 1.0 sec
Output Frequency
0-6.00 kVDC Delay: 0, 0.5 - 999.99 sec (0=continuous)
AC Waveform
DC Output Ripple Resolution: 0.01 kV
Dwell Timer FPO± (1.5% of setting + 5 V)
Ramp Timer Accuracy: GENERAL SPECIFICATIONS
Leakage Failure 294 DC only
Settings 295, 298 50/60 Hz Selectable Continuity Feature Range: 1 - 1.50 Ω
296, 297 DC and 50/60 Hz Selectable Resolution: 0.01 Ω
Voltmeter Accuracy ± 0.1% Accuracy: ± (2% of setting + 0.02 Ω)
Memories 5 (10 optional)
Sine Wave, Crest Factor = 1.3 - 1.5 Remote I/O Input: Test, Reset, Interlock
Output: -Pass, Fail, Test-in-Process
294 <5% ( 6 kVDC / 5mA atResistive Load) Hardware Interlock - a relay on the
296 high voltage output opens when
297 the Interlock signal is disabled.
0, 0.2 - 60 sec (0=continuous), 0.1 sec/step 3mA AC/DC 294 Range: 0.00 - 3.00 mA
Current Limit 295 Resolution: 0.01 mA
0.2 - 180 sec, 0.1 sec/step (optional) 296 Accuracy: ± (2% of setting + 0.02mA)
297
295 AC High Limit: 0.10 - 12.00 mA Meter Max
296 AC Low Limit: 0.00 - 12.00 mA (optional) Displays the maximum voltage value recorded during
297 AC Resolution: 0.01 mA Imax a breakdown.
298 Accuracy: ± (2% of setting + 0.2 mA) (optional)
Security Displays the maximum leakage current value read
295 DC High Limit: 0.10 - 99.99 mA during a test
296 DC Low Limit: 0.00 - 99.99 mA
297 DC Resolution: 0.01 mA Switch between two security levels:
Range: Accuracy: ± (2% of setting + 0.2 mA)
Resolution: 1. Run - operator can only run a test. No ability to
Accuracy: High Limit: 0.02 - 5.00 mA change memory locations or edit test parameters.
Low Limit: 0.00 - 5.00 mA
Resolution: 0.01 mA Safety Mark 2. Mem - Operator can run a test and change memory
Accuracy: ± (2% of setting + 0.2 mA) locations. No ability to edit test parameters.
AC 0.10 - 12.00 mA CE/cTUVus
DC 0.02 - 5.00 mA
0.01 mA Specifications subject to change without notice.
± (2% of reading + 0.02 mA)
Discharge Time < 50 msec for no load, < 100 msec for capacitive load
Toll Free 800-504-0055 Phone +1-847-932-3662 19
INDEX
4000 SERIES SPECIFICATIONS
INPUT (294, 295, 296, 297, 298) INSULATION RESISTANCE TEST MODE (297 only)
Voltage 100-120 VAC / 200-240 VAC ± 10% Auto Range Output Voltage Range: 0.1-1.00 kVDC
Frequency 50/60 Hz ± 5% Resolution: 0.01 kV
Accuracy: ± (1.5% of setting + 3 V)
Fuse 3.15 A / 250 VAC Fast-Blow Resistance Display Range: 1 - 1000 MΩ
Resolution: 1 MΩ
Accuracy: 100-499 V ± (7% of setting + 2 MΩ)
500-1000 V ± (3% of setting + 2 MΩ)
DIELECTRIC WITHSTAND TEST MODE
0, 1 - 1000 MΩ
Output Rating 298 AC 0-5.00 kVAC, 99.99 mA Hi-Limit Range: 1 MΩ
Lo-Limit Resolution:
294 DC 0-6.00 kVDC, 5.00 mA 1 - 1000 MΩ (0=off)
296 Range: 1 MΩ
297 Resolution:
Voltage Setting Range: 0-5.00 kVAC Timer Range: 0.2 or 1.0 sec
Output Frequency
0-6.00 kVDC Delay: 0, 0.5 - 999.99 sec (0=continuous)
AC Waveform
DC Output Ripple Resolution: 0.01 kV
Dwell Timer FPO± (1.5% of setting + 5 V)
Ramp Timer Accuracy: GENERAL SPECIFICATIONS
Leakage Failure 294 DC only
Settings 295, 298 50/60 Hz Selectable Continuity Feature Range: 1 - 1.50 Ω
296, 297 DC and 50/60 Hz Selectable Resolution: 0.01 Ω
Voltmeter Accuracy ± 0.1% Accuracy: ± (2% of setting + 0.02 Ω)
Memories 5 (10 optional)
Sine Wave, Crest Factor = 1.3 - 1.5 Remote I/O Input: Test, Reset, Interlock
Output: -Pass, Fail, Test-in-Process
294 <5% ( 6 kVDC / 5mA atResistive Load) Hardware Interlock - a relay on the
296 high voltage output opens when
297 the Interlock signal is disabled.
0, 0.2 - 60 sec (0=continuous), 0.1 sec/step 3mA AC/DC 294 Range: 0.00 - 3.00 mA
Current Limit 295 Resolution: 0.01 mA
0.2 - 180 sec, 0.1 sec/step (optional) 296 Accuracy: ± (2% of setting + 0.02mA)
297
295 AC High Limit: 0.10 - 12.00 mA Meter Max
296 AC Low Limit: 0.00 - 12.00 mA (optional) Displays the maximum voltage value recorded during
297 AC Resolution: 0.01 mA Imax a breakdown.
298 Accuracy: ± (2% of setting + 0.2 mA) (optional)
Security Displays the maximum leakage current value read
295 DC High Limit: 0.10 - 99.99 mA during a test
296 DC Low Limit: 0.00 - 99.99 mA
297 DC Resolution: 0.01 mA Switch between two security levels:
Range: Accuracy: ± (2% of setting + 0.2 mA)
Resolution: 1. Run - operator can only run a test. No ability to
Accuracy: High Limit: 0.02 - 5.00 mA change memory locations or edit test parameters.
Low Limit: 0.00 - 5.00 mA
Resolution: 0.01 mA Safety Mark 2. Mem - Operator can run a test and change memory
Accuracy: ± (2% of setting + 0.2 mA) locations. No ability to edit test parameters.
AC 0.10 - 12.00 mA CE/cTUVus
DC 0.02 - 5.00 mA
0.01 mA Specifications subject to change without notice.
± (2% of reading + 0.02 mA)
Discharge Time < 50 msec for no load, < 100 msec for capacitive load
20 hipot.com
SAFETY MADE SIMPLE®
INDEX
290 SERIES SPECIFICATIONS
INPUT (294, 295, 296, 297, 298) INSULATION RESISTANCE TEST MODE (297 only)
Voltage 100-120 VAC / 200-240 VAC ± 10% Auto Range Output Voltage Range: 0.1-1.00 kVDC
Resolution: 0.01 kV
Frequency 50/60 Hz ± 5% Accuracy: ± (1.5% of setting + 3 V)
Fuse 3.15 A / 250 VAC Fast-Blow Resistance Display Range: 1 - 1000 MΩ
Resolution: 1 MΩ
Accuracy: 100-499 V ± (7% of setting + 2 MΩ)
500-1000 V ± (3% of setting + 2 MΩ)
DIELECTRIC WITHSTAND TEST MODE
Output Rating 298 AC 0-5.00 kVAC, 99.99 mA Hi-Limit Range: 0, 1 - 1000 MΩ
Lo-Limit Resolution: 1 MΩ
294 DC 0-6.00 kVDC, 5.00 mA Timer
296 Range: 1 - 1000 MΩ (0=off)
297 Resolution: 1 MΩ
Voltage Setting Range: 0-5.00 kVAC Range: 0.2 or 1.0 sec
0-6.00 kVDC Delay: 0, 0.5 - 999.99 sec (0=continuous)
Resolution: 0.01 kV
Accuracy: ± (1.5% of setting + 5 V) GENERAL SPECIFICATIONS
Output Frequency 294 DC only Continuity Feature Range: 1 - 1.50 Ω
Resolution: 0.01 Ω
295, 298 50/60 Hz Selectable Accuracy: ± (2% of setting + 0.02 Ω)
296, 297 DC and 50/60 Hz Selectable Memories 5 (10 optional)
Accuracy ± 0.1%
AC Waveform Sine Wave, Crest Factor = 1.3 - 1.5 Remote I/O Input: Test, Reset, Interlock
Output: -Pass, Fail, Test-in-Process
3mA AC/DC
DC Output Ripple 294 <5% ( 6 kVDC / 5mA at Resistive Current Limit Hardware Interlock - a relay on the
Dwell Timer 296 Load) (optional) high voltage output opens when
297 Meter Max the Interlock signal is disabled.
0, 0.2 - 60 sec (0=continuous), 0.1 sec/step (optional)
Imax 294 Range: 0.00 - 3.00 mA
Ramp Timer 0.2 - 180 sec, 0.1 sec/step (optional) 295 Resolution: 0.01 mA
Security 296 Accuracy: ± (2% of setting + 0.02mA)
Leakage Failure 295 AC High Limit: 0.10 - 12.00 mA 297
Settings 296 AC Low Limit: 0.00 - 12.00 mA
297 AC Resolution: 0.01 mA Displays the maximum voltage value recorded during
Voltmeter Accuracy: ± (2% of setting + 0.2 mA) a breakdown.
Discharge Time
298 High Limit: 0.10 - 99.99 mA Displays the maximum leakage current value read
Low Limit: 0.00 - 99.99 mA during a test
Resolution: 0.01 mA
Accuracy: ± (2% of setting + 0.2 mA) Switch between two security levels:
295 DC High Limit: 0.02 - 5.00 mA 1. Run - operator can only run a test. No ability to
296 DC Low Limit: 0.00 - 5.00 mA change memory locations or edit test parameters.
297 DC Resolution: 0.01 mA
Accuracy: ± (2% of setting + 0.2 mA) 2. Mem - Operator can run a test and change memory
locations. No ability to edit test parameters.
Range: AC 0.10 - 12.00 mA Safety Mark
DC 0.02 - 5.00 mA CE/cTUVus
Resolution: 0.01 mA
Accuracy: ± (2% of reading + 0.02 mA) Specifications subject to change without notice.
< 50 msec for no load, < 100 msec for capacitive load
Toll Free 800-504-0055 Phone +1-847-932-3662 21
INDEX
260 SERIES SPECIFICATIONS
INPUT GENERAL SPECIFICATIONS
Voltage 264 100 - 120 VAC / 200 - 240 VAC ± Memories 5
10% Auto Range
Frequency Remote I/O Input: Test, Reset, Interlock
Fuse 266 100 - 240 VAC ± 10% Full Range
Voltage Drop Output: Pass, Fail, Test-in-Process
50/60Hz ± 5% Display (optional)
Voltage Limit Settings Hardware Interlock - a relay on the high voltage
264 10A / 250 VAC Slow-Blow output opens when the Interlock signal is
266 15A / 250 VAC Slow-Blow disabled.
GROUND BOND TEST MODE Display the voltage drop across the circuit instead
of the resistance measurement.
Output Rating 264 Current 3.0 - 40.0 AAC
3.0 - 60.0 AAC 264 0.00 - 6.00 VAC
266 266 0.00 - 9.00 VAC
Resolution: 0.1 A Offset Limit Settings Resolution: 0.01 V
Accuracy: ± (2% of setting + 0.02 V)
Regulation: ± (2% of setting + 0.1A)
264 0.00 - 4.00 VAC
264 Voltage 6 VAC (fixed)
266 0.00 - 6.00 VAC
266 Voltage 12 VAC (fixed)
Output Frequency Safety Mark Resolution: 0.01 V
Resistance Limit 50Hz/60Hz User Selectable Accuracy: ± (2% of setting + 0.02 V)
Settings Accuracy: ± 0.1%
264 0 - 150 mΩ for 30.1 - 40.0 A CE/cTUVus
Offset Limit Settings
Dwell Time Setting 0 - 200 mΩ for 10.1 - 30.0 A Specifications subject to change without notice.
0 - 600 mΩ for 3.0 - 10.0 A
266 0 - 150 mΩ for 30.1 - 60.0 A
0 - 200 mΩ for 15.1 - 30.0 A
0 - 600 mΩ for 3.0 - 15.0 A
Resolution: 1 mΩ
Accuracy: ± (2% of setting + 2 mΩ)
0 - 100 mΩ
Resolution: 1 mΩ
Accuracy: ± (2% of setting + 2 mΩ)
0, 0.5 - 240.0 sec (0=continuous), 0.1 sec/step
Ramp Time 0.1 sec fixed
Measurement 264 0.0 - 40.0 AAC
Current 266 0.0 - 60.0 AAC
Ohmmeter Resolution: 0.1 A
Accuracy: ± (3% of reading + 0.1 A)
264 0 - 600 mΩ
Resolution: 1 mΩ
Accuracy: ± (3% of reading + 3
mΩ) for 3 - 5.9 A
266 0 - 600 mΩ
Resolution: 1 mΩ
Accuracy: ± (3% of reading + 3
mΩ) for 3 - 5.9 A
± (2% of reading + 2
mΩ) for 6 - 40 A
22 hipot.com
SAFETY MADE SIMPLE®
INDEX
2200 SERIES SPECIFICATIONS
INPUT (294, 295, 296, 297, 298) INSULATION RESISTANCE TEST MODE (297 only)
Voltage 100-120 VAC / 200-240 VAC ± 10% Auto Range Output Voltage Range: 0.1-1.00 kVDC
Frequency 50/60 Hz ± 5% Resolution: 0.01 kV
Accuracy: ± (1.5% of setting + 3 V)
Fuse 3.15 A / 250 VAC Fast-Blow Resistance Display Range: 1 - 1000 MΩ
Resolution: 1 MΩ
Accuracy: 100-499 V ± (7% of setting + 2 MΩ)
500-1000 V ± (3% of setting + 2 MΩ)
DIELECTRIC WITHSTAND TEST MODE
0, 1 - 1000 MΩ
Output Rating 298 AC 0-5.00 kVAC, 99.99 mA Hi-Limit Range: 1 MΩ
Lo-Limit Resolution:
294 DC 0-6.00 kVDC, 5.00 mA 1 - 1000 MΩ (0=off)
296 Range: 1 MΩ
297 Resolution:
Voltage Setting Range: 0-5.00 kVAC Timer Range: 0.2 or 1.0 sec
Output Frequency
0-6.00 kVDC Delay: 0, 0.5 - 999.99 sec (0=continuous)
AC Waveform
DC Output Ripple Resolution: 0.01 kV
Dwell Timer FPO± (1.5% of setting + 5 V)
Ramp Timer Accuracy: GENERAL SPECIFICATIONS
Leakage Failure 294 DC only
Settings 295, 298 50/60 Hz Selectable Continuity Feature Range: 1 - 1.50 Ω
296, 297 DC and 50/60 Hz Selectable Resolution: 0.01 Ω
Voltmeter Accuracy ± 0.1% Accuracy: ± (2% of setting + 0.02 Ω)
Memories 5 (10 optional)
Sine Wave, Crest Factor = 1.3 - 1.5 Remote I/O Input: Test, Reset, Interlock
Output: -Pass, Fail, Test-in-Process
294 <5% ( 6 kVDC / 5mA atResistive Load) Hardware Interlock - a relay on the
296 high voltage output opens when
297 the Interlock signal is disabled.
0, 0.2 - 60 sec (0=continuous), 0.1 sec/step 3mA AC/DC 294 Range: 0.00 - 3.00 mA
Current Limit 295 Resolution: 0.01 mA
0.2 - 180 sec, 0.1 sec/step (optional) 296 Accuracy: ± (2% of setting + 0.02mA)
297
295 AC High Limit: 0.10 - 12.00 mA Meter Max
296 AC Low Limit: 0.00 - 12.00 mA (optional) Displays the maximum voltage value recorded during
297 AC Resolution: 0.01 mA Imax a breakdown.
298 Accuracy: ± (2% of setting + 0.2 mA) (optional)
Security Displays the maximum leakage current value read
295 DC High Limit: 0.10 - 99.99 mA during a test
296 DC Low Limit: 0.00 - 99.99 mA
297 DC Resolution: 0.01 mA Switch between two security levels:
Range: Accuracy: ± (2% of setting + 0.2 mA)
Resolution: 1. Run - operator can only run a test. No ability to
Accuracy: High Limit: 0.02 - 5.00 mA change memory locations or edit test parameters.
Low Limit: 0.00 - 5.00 mA
Resolution: 0.01 mA Safety Mark 2. Mem - Operator can run a test and change memory
Accuracy: ± (2% of setting + 0.2 mA) locations. No ability to edit test parameters.
AC 0.10 - 12.00 mA CE/cTUVus
DC 0.02 - 5.00 mA
0.01 mA Specifications subject to change without notice.
± (2% of reading + 0.02 mA)
Discharge Time < 50 msec for no load, < 100 msec for capacitive load
Toll Free 800-504-0055 Phone +1-847-932-3662 23
INDEX
COMMON SAFETY STANDARD REFERENCE CHART
Standard / Testing Dielectric Withstand Ground Bond/Continuity Earth Insulation Suggested
Harmonized Type Leakage Resistance Model #
Standard Performance Test Voltage Max I. Test Test V Max. R Test Time Test Max I. Test V Min Slaughter
Production 500 – 4000 VAC Time Current Limit Voltage Time Limit R Tester
IEC/UL 60601-1
3rd Edition Medical or 707 – 5656 VDC 60 s 10-25 A ≤6V ≤ 0.1 Ω 5s 110% x 5-10 mA N/A 6330
Electrical Equipment 1000 – 3000 VAC No Breakdown ≤6V ≤ 0.1 Ω 5s rated V
1 or 60 s 10-25 A N/A N/A 4320, 4520
Performance 900-1079 VAC No Breakdown 60 s Continuity 1305, 1340,
Production or 1273-1526 VDC Continuity N/A N/A 2503, 2510,
H.U.D. Specification Continuity
#24 CFR 3280.810 1080-1250 VAC Continuity 2550
or 1527-1768 VDC 1305, 1340,
No Breakdown 1 s N/A N/A 2503, 2510,
2550
Performance 900 VAC or 1280 VDC No Breakdown 60 s 1305, 1340,
N/A N/A 2503, 2510,
R.V.I.A. (NEC) 2550
1305, 1340,
Production 1080 VAC or No Breakdown 1 s N/A N/A 2503, 2510,
1530 VDC 2550
IEC 60335-1 Performance 500 – 2400 VAC x rated V No Breakdown 60 s ≥ 10 A ≤ 12 V 0.1 – 0.2 ≤ 120 s 1.06 x 0.25 – N/A 6330, 2525
+ 2400 VAC Ω rated V 5.0 uA
Household Electrical
Appliances
Production 400 – 2500 VAC 5-30 mA 1s ≥ 10 A ≤ 12 V 0.1 – 0.2 No time N/A N/A 4520
Ω specified
UL 60335-1 Performance 500 V – 2400 VAC x rated No Breakdown 60 s 40 A ≤ 6.5 V ≤ 0.5 Ω 120 s 1.06 x 0.25 – N/A 6330, 2525
V + 2400 VAC rated V 5.0 uA
Household Electrical
Appliances
Production 400 – 2500 VAC 5-30 mA 1s 40 A ≤ 12 V 0.1 – 0.2 No time N/A N/A 4520
Ω specified
IEC 60598-1 Performance 500 – 4 x rated V + 2000 No Breakdown 60 s ≥ 10 A ≤ 12 V ≤ 0.5 Ω 60 s Rated V 0.5 – 10 60 s 500 1-4 6330
Luminaires VAC mA VDC MΩ
Production Not Specified - Responsibility of Manufacturer 2955, 2965,
2975
Performance 1000 VAC - 1000 VAC x 2 60 s 30 A ≤ 4 V ≤ 0.1 Ω 120 s N/A No time 500 ≥2 4320, 4520
x rated V specified VDC MΩ
UL 1598 Luminaires No Breakdown
Production 1200 VAC 1s Continuity ≤ 0.1 Ω Continuity N/A N/A 2955, 2965,
2975
Performance ≤ 10 ≤ 0.1 Ω 60 or 120 s < 300 V 0.5 mA N/A 6330
Production 5 - 60 s 25 or 30 A V or ≤ or <4 V No time
IEC/UL 61010-1 & Performance 12 V 0.133 Ω specified 2965, 2975
CSA 22.2 No. 61010- 840 - 11940 VAC or 1200
1 Laboratory Control - 7500 VDC No Breakdown 5 s max 4320, 4520
Test & Measurement ramp 1340, 2503,
Equipment up Continuity N/A N/A 2550, 2955,
EN 60204-1 2s 2965, 2975
Electrical Equipment dwell 6330
of Machines 1340, 2503,
UL 45A Portable 2 x rated V or No Breakdown 1 s 0.2 - Refer to N/A No time 500 V ≥1 2510, 2550,
Electrical Appliances 1000 VAC 10 A ≤ 24 V Section specified MΩ 2955, 2965,
2975
18.2.2
Production Not Specified - Responsibility of Manufacturer
Performance 1000 VAC + 2 x rated V 60 s Continuity < 300 V 0.5 – 3.5 60 s 500 V ≥ 50
or DC equivalent Continuity mA KΩ
Production 1000 - 3000 VAC No Breakdown N/A N/A
1s
EN 60950-1 EN Performance 1000 – 3000 VAC 120 s 30 A ≤ 12 V ≤ 0.1 Ω 60 s < 300 V 0.25 – 60 s 500 V ≥2 6330
50116 Information Production or 1414 – 4242 VDC 1-4 s 3.5 mA MΩ
Technology Performance No Breakdown 60 s
Equipment 1-4s 25 A ≤ 12 V ≤ 0.1 Ω N/A N/A 4320, 4520
UL 60950-1 CSA Production
22.2 No. 60950- 60 s ≤ 40 A ≤ 12 V ≤ 0.1 Ω < 300 V 0.25 – 60 s 500 V ≥2 6330
1 Information Continuity 3.5 mA MΩ
Technology No Breakdown
Equipment 1000 – 3000 VAC 1–6s 1340, 2503,
or 1414 – 4242 VDC 2510, 2550,
N/A N/A 2955, 2965,
2975
INTERNATIONAL PRESENCE
We have sales representatives located throughout the world to assist you in purchasing the
right electrical safety tester for your needs. These offices also provide local product support.
Please call +1 847-932-3662 for more information