The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.

PROPAK Asia 2022 Catalog Original (Hyperlink)-2

Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by warunchalees, 2022-05-25 23:22:35

PROPAK Asia 2022 Catalog Original (Hyperlink)-2

PROPAK Asia 2022 Catalog Original (Hyperlink)-2

SMC Automation, Le ading Expert for Innovative Automation

Efficiency Energy-saving

Reduced Decreased air blow air
maintenance time consumption without
sacrificing work quality
Eco-Products Eco-Factory
Pneumatic

Optimization

Extended pneumatic Reduced silencer
equipment life exhaust noise

Energy saving

Long Safety
Service Life

SMC (Thailand) Ltd. ECO-Product

134/6 Moo5, Tiwanon Rd., Bangkadi, Amphur Muang, Patumthani 12000
Tel : 0-2019-5656



Index

1 Equipment for
the Food Manufacturing Industry

3 Bacteria Removal Filter

4 EHEDG Compliant/Clean Design/
FDA Compliant Fittings

5 Compressed Air
Preparation Filter

6 Clean Design Manifold Valve

7 Electric Actuator

9 Step Motor Controller
JXC Series

11 IO-Link Compatible Products

13 Eco-product

15 Ionizer
17 Thermo Chiller/

18 12 Services
19 Training Center
20
BCP&SDGs

Equipment for
the Food Manufacturing Industry

HF1- Series HF2- Series HF1 / HF2

Fluid contact parts Fluid contact parts Compatible Products

No grease or NSF H1 grade No grease or NSF H1 grade Available without prefix
grease grease
FDA compliant materials

Applicable for a diverse range of food manufacturing processes / Possible to blow directly onto food /
Designed for hygiene management in accordance with HACCP and other standards

Transfer Box Stirring / Filling Cooling
making Mixing Drying
Packaging Cleaning

HF Series

1

Application Examples

¡Removal of particles on the container ¡Blowing air onto breads

Air Preparation Equipment Direct Operated Bacteria Air Preparation Equipment Direct Operated Bacteria
HF1-AFF/AM Series 2-Port Solenoid Valve Removal Filter HF1-AFF/AM Series 2-Port Solenoid Valve Removal Filter
HF1-JSX Series SFDA Series HF1-JSX Series SFDA Series
p. 5 p. 5
p. 57 p. 4 p. 57 p. 4

¡Nitrogen filling of packing machine ¡Stirring

2-Color Display Direct Operated Bacteria Restrictor In-line Type Direct Operated Bacteria
Digital Flow Switch 2-Port Solenoid Valve Removal Filter HF1-AS-X214 2-Port Solenoid Valve Removal Filter
PF2M7 Series HF1-JSX Series SFDA Series HF1-JSX Series SFDA Series
p. 40
p. 54 p. 57 p. 4 p. 57 p. 4

Pneumatic equipment circuit of air blower for food application (example)

ISO 8573-1 ISO 8573-1 ISO 8573-1
Purity class Purity class Purity class

[7:9:4] [5:4:4] [1:4:1]

Pressure switch

F
P

Main line filter Air filter Mist separator Micro Mist Separator Activated Flow switch 2-port valve Restrictor In-line filter Blow nozzle
(3-port valve)
Nominal filtration Regulator Nominal filtration Nominal filtration carbon filter Nominal filtration
rating: 5 μm
Line filter rating: rating: Oil concentration rating:
0.01 μm
Nominal filtration 0.1 μm 0.01 μm 0.003 mg/m3
rating: 1 μm

Refrigerated air dryer ฀ Please use HF Series or HF compatible products on the downstream side refrigerated air dryer.

2

Bacteria Removal Filter RoHS

Hollow Fiber Element

Captures bacteria in the compressed air

Bacteria Capture ฀1 ¡Uses FDA/Food Sanitation Law compliant
Performance materials฀2

LRV ≥ 9 ¡Grease-free

Contributes to the hygiene control of HACCP, etc., and
FSSC22000 certification acquisition!

฀1 LRV (Log Reduction Value): A mathematical representation of the bacteria capture performance of the filter element ฀2 Parts in contact with fluid: Resin/Rubber

Nominal Initial pressure Max. operating Flow rate
filtration rating drop pressure
500
0.01 μm 0.03 MPa 1.0 MPa
L/min (ANR)
Filtering efficiency 99.99% Inlet pressure 0.7 MPa, At 20°C
at max. flow rate

Applications

¡For air blow used to open
packaging bags

¡For the air blow of ice cream
lids and cups

¡For nitrogen blow used when
filling rice bags (to prevent
oxidation)

SFDA Series

3

For Food Industry

EHEDG Compliant/Clean Design/
FDA Compliant Fittings

RoHS

Hygienic design prevents liquid from accumulating
after cleaning
FDA compliant materials

EHEDG Compliant Fittings

EHEDG Compliant
IP69K

Hygienic Design
FDA Compliant

Stainless Steel 316 Insert Fittings

KFG2H -E Series

Clean Design Fittings

Hygienic Design
FDA Compliant

Stainless Steel 316 Insert Fittings

KFG2H -C Series

FDA Compliant Fittings

FDA Compliant

Stainless Steel 316 One-touch Fittings Metal One-touch Fittings Stainless Steel 316 Insert Fittings

KQG2-F Series KQB2-F Series KFG2-F Series

KFG2H-E/KFG2H-C/KQGB2-F KFG2-F Series 4

Modular Connection Type RoHS

Compressed Air Ne w
Preparation Filter
Sizes 50 and 60 have been
Compressed Air Purity Class ISO 8573 added.
An element service
Deodorization Solid/Oil Separation Line Filter AFF Series 1 Water indicator has been added.∗1
μm droplet
removal *1 Excludes the AMK

Flow capacity L/min (ANR)

20 Up to 300

Mist Separator AM Series 0.1 Oil mist 30 Up to 750
separation
μm
and
removal

0.01 Oil mist 40 Up to 1500
separation
Micro Mist Separator AMD Series and
μm removal Ne w 50 Up to 2200

Activated Carbon Filter AMK Series Oil concentration Oil vapor

0.003 and odor Ne w 60 Up to 3700

mg/m3 removal

Weight reduced by 50% Modular connection
is possible.
AFF/AM/AMD20-D: 0.19 kg (Existing model: 0.38 kg)

Face-to-face and depth

dimensions reduced by 30%

AFF/AM 30-D: 53 mm (Existing model: 76 mm)

Ne w

New With element
service indicator

AFF/AM/AMD/AMK Series

5

Clean Design Manifold Valve

Low fluid accumulation IP69K
Easy to clean

Large flow rate

1,600*1
L/min (ANR)

Enclosure: IP69K

NSF-H1 grease 81

External parts: FDA-compliant materials *2 mm

Metal parts are made of stainless steel 316 with high anti-corrosion performance. 166 mm 233 mm

Wiring: Lead wire/ (When 5 stations are used)
Fieldbus type
(∗ The serial unit is not included in the number of stations.)

* 1 When the inlet side is 0.6 MPa, and the outlet side is 0.5 MPa (20°C) The photo shows the IO-Link compatible manifold.
* 2 The lead wire type cable is not made of FDA-compliant materials.

Crevice free exterior and can be Sub-plate (Single unit)
cleaned without disassembly
IP69K compliant
Cleanable space between valves Valve width is 15 mm.

JSY5000

Plug-in type

Valve width: 15 mm

JSY5000-H Series

6

Electric Actuator ∗ Excludes auto
High Performance Slider Type switches

Battery-less Absolute (Step Motor 24 VDC) For details, refer to page 57 and onward.

Reduces cycle time

Cycle time 39Reduced by % (0.57 s 0.93 s)

Acceleration/ compared with the existing model∗1
Deceleration
∗1 When LEFS25GH-400 is operated from 0 to 400 mm
Max. speed
10000 mm/s2

(334% increase compared with the existing model)

1500 mm/s

(Improved by 25% compared with the existing model)

Speed [V] New JXC5H/6H Series

Existing
model

Time [T]

High Performance EtherCAT/EtherNet/IP™/
Step Motor Controller PROFINET

Higher acceleration and maximum speed can be set JXCEH/9H/PH Series
with the special controller (for LEFS G Series).

Parallel I/O

JXC5H/6H Series

LEFS G Series

7

Electric Actuator
High Rigidity and High Precision Slider Type Fordetails,referto

page 53 and onwards.

Circular arc grooves allow for
high rigidity and high precision.

Moment resistance *1 *2

Improved by

61%up to

Table displacement *1

Reduced by

50%up to

*1 Compared with the LEFS With internal battery-less absolute encoder
*2 Size 40, Mep, Overhang: 300 mm
*3 Excludes the lead H Restart from the last stop position is possible after
recovery of the power supply.
Reduced maintenance (No need to manage or replace batteries)

Positioning repeatability: ±0.01 mm *3

Step Motor Controller JXC Series

Battery-less Absolute Type (Step Motor 24 VDC)

Direct input type

<Applicable network>

Step data input type

LEKFS Series

8

Step Motor Controller JXC Series

Fieldbus Network

EtherCAT/EtherNet/IP™/PROFINET/
DeviceNet®/IO-Link/CC-Link Direct Input Type
Step Motor Controller/JXC Series p.18

With
STO
sub-
function

JXCE1 JXC91 JXCP1 JXCD1 JXCL1 JXCLF JXCM1

Two types of operation command Transition wiring of communication cables

Step no. defined operation: Operate using the preset Two communication ports are provided.
step data in the controller. For the DeviceNet® type and CC-Link type, transition wiring is
Numerical data defined operation: The actuator operates possible using a branch connector.
using values such as position and speed from the PLC. 1 to 1 in the case of IO-Link

Numerical monitoring available PLC

Numerical information, such as the current speed, current
position, and alarm codes, can be monitored on the PLC.

Application Communication protocols

PLC Can be additionally installed in
an existing network
Both air and electric systems can be established
under the same protocol. IO-Link Communication

Electric Actuators Air Cylinders IO-Link
master
EX260

<Applicable Electric Actuators>

High Rigidity and Slider Type Low Profile Slider Type Guide Rod Slider Rod Type
LEF Series LEM Series LEL Series LEY/LEYG Series
High Precision Slider Type
LEKFS Series

Slide Table/High Precision Type Slide Table Miniature Type Gripper Rotary Table
LESYH Series LES/LESH Series LEPY/LEPS Series LEH Series LER Series

9

Step Motor Controller JXC Series

System Construction/General Purpose I/O

Electric actuator/ Provided by the customer
Slider type PLC

Power supply for I/O signal
24 VDC

Controller 1 I/O cable p. 16

Web Catalog Part no.
LEC-CN5-

Actuator cable 1 p. 14, 15 To the parallel I/O connector
To SI
Compatible encoder Incremental Battery-less To SI
Cable type absolute

Standard cable LE-CP- -S — To ENC
To MOT
Robotic cable LE-CP- LE-CE-

1 Can be included as an option. Refer to the “How
to Order” page of the actuator.

Provided by the customer To PWR Step data input type Communication cable
JXC51/61 p. 16 (3 m)
Power supply Power supply p. 8
for controller plug p. 16
(Accessory)
24 VDC

Options

Teaching box p. 16 Communication cable for controller setting p. 16 Conversion cable 2 p. 16
(With 3 m cable) P5062-5
LEC-T1-3 G Communication cable : JXC-W2A-C (0.3 m)

USB cable : LEC-W2-U The conversion cable can
be used for connecting this
<Controller setting software/USB driver> controller to the optional
· Controller setting software teaching box [LEC-T1]
· USB driver (For JXC-W2A-C) offered with the LEC series.

Download from SMC’s website:
or https://www.smcworld.com

USB cable Conversion cable
(A-mini B type) p. 16
(0.8 m)

PC

2 A conversion cable is also required to connect the JXC 1 series controller and the LEC series communication cable (LEC-W2A-C).
(A conversion cable is not required for the JXC-W2A-C.)

10

IO-Link Compatible Products

Configuration File 1 IODD File: IO-Link is an open communication
(IODD File 1) interface technology between the
• Manufacturer IODD is an abbreviation of IO Device sensor/actuator and the I/O termi-
• Product part no. Description. This file is necessary for nal that is an international stand-
• Set value setting the device and connecting it to a ard, IEC61131-9.
master. Save the IODD file on the PC to
PC be used to set the device prior to use. IO-Link Master
(Commercially available)
PLC

Various fieldbusses

Device settings can Read the device data.
be set by the master.
• Sensor measured values and ON/OFF signals
• Parameter value • Device information and parameter values
• Control data, etc. • Status information and diagnostic data

PROFINET compatible EtherNet/IP™ compatible CC-Link IE Field compatible

SI unit IO-Link master SI unit IO-Link master SI unit IO-Link master

EX600-SPN3 EX600-L B1 EX600-SEN3-X80 EX600-L B1 EX600-SCF -X60 EX600-GILB-X60
EX600-SPN4

Power
supply

IO-Link master SI unit

Product 3-Screen Display 3-Screen Display 3-Screen Display 3-Screen Display 3-Screen Display
Series
High-Precision High-Precision High-Precision Multi-Channel Digital Gap Checker
Digital Pressure Switch Digital Pressure Switch Digital Pressure Switch Digital Sensor Monitor

for Air for General Fluids

Click here Click here Click here Click here Click here

1.0 MPa 1.0 MPa
1.6 MPa 2.0 MPa
5.0 MPa
10 MPa

Process data size ZSE20B(F)-L/ ISE70/ISE71-L2 ISE70G/ISE75G-L2 PSE200A ISA3-L
ISE20B-L ISE76G/ISE77G-L2
Internal 2-byte input 10-byte input 8-byte input
failure 2-byte input 2-byte input

Diagnostic/Status monitoring function Abnormal internal OUT2 OUT2 Below lower limit of pressure range
temperature OUT2

Outside of Over current Pressure sensor failure
rated range
Applied pressure error/ Pressure diagnosis/Error diagnosis
Event Short-circuit Differential pressure measurement error
data detection

Open-circuit
detection

External power
supply failure

Other

Process Diagnostic
data bit

C1

11

IO-Link Compatible Products

Product 2-Color Display 3-Color Display 3-Color Display Digital 3-Color Display Digital Flow Switch for Water

Digital Flow Switch Digital Flow Switch Flow Switch for Large Flow

Click here Click here Click here Click here

Series

PF2M7-L PFMC7-L PF3A7 H-L PF3W-L Manifold
PF3WB/C/R
Process data size 4-byte input 4-byte input 4-byte input
6-byte input

Diagnostic/Status monitoring function Internal
failure

Abnormal internal
temperature

Outside of
rated range

Event Short-circuit
data detection

Open-circuit
detection

External power
supply failure

Other Overflow error/Accumulated flow error Overflow error/Accumulated flow error Overflow error/Accumulated flow error/
Over current error

Process Diagnostic Flow diagnosis
data bit Flow diagnosis/Error diagnosis Flow diagnosis/Error diagnosis

Product Actuator Valve SI Unit Electro-Pneumatic Regulator Step Motor
Position Sensor Click here Electronic Vacuum Regulator Controller

Click here Click here Click here

Series

D-MP025/D-MP050 EX260-SIL1 ITV10 0/20 0/30 0-IL JXCL1
D-MP100/D-MP200 ITV2090-IL
4-byte output 14-byte input
Process data size 2-byte input 4-byte input 22-byte output
2-byte output
Internal
Diagnostic/Status monitoring function failure Valve output wiring Control power supply
Valve output wiring
Abnormal internal Valve power supply
temperature

Outside of
rated range

Event Short-circuit
data detection

Open-circuit
detection

External power
supply failure

Other Motor control related alarm
Reduced magnetic field strength Number of valve operations exceeded Motor control related alarm

Process Diagnostic (Switch setting) Set pressure reached
data bit Device information

2C

12

13

Lightweight Air Systems

Pressure sensor devices Directional control valve Air consuming devices,
Flow sensor devices Solenoid valve Blow guns, Actuators,
Flow control equipment,
• Flow switch Vacuum equipment, etc.
• Pressure switch
Nozzle

Are your Air blow Search for air- Solenoid valve Air cylinder
operating adjustments saving themes for Gap checker
conditions ideal? can lead to large Adsorption pad
energy savings! each device.

52 6

5 Air pressure 6 Air/Power Solenoid valve
source saving Vacuum equipment
efficiency equipment
p. 27 s 30 p. 31 s 46
• Reduce specific power Speed
• Improve operation efficiency controller

Compressor Actuators

Solenoid
valve

Energy-saving mindset Changes in upstream conductance pressure loss

9 Technical data Present 2-port valve

p. 76 s 83 Regulator
Ps
Energy consumption Energy efficient Improvement 1 Po
Filter Nozzle
Stop valve

Energy-saving Improvement 2

Cs Cn
Recommended air blow system

Ideal

Production amount

4

14

General specifications

IZF Series Filter
(IZF21/31)
Ion balance: ±5 V (IZF21/31) or ±13 V (IZF10/10R).

Minimal elimination distance: 100 mm.

Automatic cleaning function
(IZF21/31)

Flow Rate Adjustment
Function
(IZF10R/IZF21/31)

Cleaning brush Emitter

Up to 7 types
of alarms

IZS40/41/42 & IZT40/41/42 Series Separate controller and bar
- Bar can be mounted in a narrow space
Ion balance: ±30 V. - Easily monitor and adjust bars installed
Potential amplitude: 25 V or less (IZS42/IZT42 Series)
Effective electricity elimination distance: 50 to 2000 mm. in a place which cannot be accessed.

Compact design

37 mm
30 mm

Low maintenance electrode cartridges. Minimises
contamination of electrode needles by discharging
compressed air at the surface of the needles.
Two types of electrode needle materials available:
tungsten and single crystal silicon

15 For dimensions and other details refer to the general
catalogue of each series in www.smc.eu

IZN10E Series General specifications
Ionizers
Ion balance: ±10 (Energy saving) or ±15 (Large flow).
Electrode needle
Effective electricity elimination distance: 20 to 500 mm. contamination detector

Easy maintenance Built-in power supply
- Can be disassembled into 3 parts substrate
- Tools are unnecessary for the installation

or removal of the assembly.

Multiple alarms, functions and Transition wiring and remote control
LED display (IZT41/42) Up to 8 ionizers can be connected
reducing the labour time required to
Ion balance display connect power supply.
High-voltage abnormality Up to 16 ionizers can be adjust and set with
remote control through address setting.
detection
Maintenance detection

IZT40/41/42

IZS40/41/42

Electrode needle
contamination detector

Incorrect high voltage ion
discharge detection

16

17

12 Services

By providing the latest pneumatic technology,
SMC continues to create solutions for your automation needs.

1 DEDICATED 2 LOCAL 3 DESIGN 4 MACHINE
CORPORATE FACTORY ENGINEERING SAFETY
ACCOUNT SUPPORT SUPPORT SUPPORT
MANAGER
SMC has over 6,000 local sales engineers To fully support your Engineers - SMC has SMC will work with your Engineering and
An SMC Corporate Account Manager in 83 countries to support all of your local 1600 dedicated R&D Engineers that can local facilities for design assistance related to
is assigned as your one-point person production facilities. develop new products or solutions. SMC plant safety upgrades to meet ISO 13849-1
of contact. They work closely with your can quickly customize or modify existing or other Machine Directives.
Corporate HQ Sponsors, Engineers and components to meet design standards or
all production facilities - to deliver, create, unique applications.
manage and execute all collaborative
program objectives.

5 OEM MACHINE 6 CRITICAL With 12 support programs 8 MACHINE
SUPPLIER SPARE PARTS focusing on ANALYSIS
SUPPORT FOR NEW OEM ASSESSMENTS
MACHINES energy-saving activities
SMC will perform plant level machine
SMC will support your OEM Machine SMC will work with local factories receiving 7 COMPRESSED analysis to improve machine performance,
AIR ENERGY identify waste, reduce scrap rate and
suppliers with the integration of SMC new OEM machines - to ensure all critical SAVINGS improve line efficiency.
ASSESSMENTS
specified components. SMC will provide spare parts are available and onsite prior to
SMC has developed a Streamlined
pricing support, innovative design assistance Energy Savings Assessment
program for our Corporate Accounts.
production. and SMC project management to ensure Our goal is to find innovative
solutions to reduce waste of
on-time delivery and commissioning of new compressed air in the factory
environment.
machines or lines.

9 STOREROOM 10 HIGH USAGE 11 IMPROVEMENT 12 ONSITE &
ASSESSMENTS SPARE PARTS ACTIVITY ONLINE
ANALYSIS REPORTS TRAINING
SMC will perform plant level storeroom CLASSES
assessments to reduce vendor base,
eliminate duplication, standardize SMC will work with all local plants to identify SMC will document all Corporate Account SMC offers customized onsite and online
components, identify critical spares and high usage pneumatic components. SMC application successes with Improvement training classes - on a variety of subjects
offer cost savings solutions. will conduct failure mode analysis and Activity Reports (IAR’s). These IAR’s are related to pneumatic components, electric
offer robust alternatives to ensure better a one-page overview of the application actuators, energy savings, optimal machine
performance and uptime on machines where - highlighting operational improvements, design and TPM methodologies.
components are used. energy savings, cost savings details or plant
process improvements. These IAR’s are
designed to be shared with other facilities to
duplicate activity.

18

19

Business Continuity Plan (BCP: Business Continuity Plan)

Mass Production Factory Tsukuba Factory Shimotsuma Europe Asia
Risk Hedging Actuators Factory
Czech Factory China Factory
Production system BCP Air Line Equipment Actuators Actuators
Solenoid Valves/Tubing Electric Actuators Actuators
90% production supply Electric Actuators Air Line Equipment
system recovery within Auto Switches Auto Switches Air Line Equipment Air Dryers/Temperature
2 weeks after a disaster Temperature Control Control Equipment*1
Yamatsuri
Factory Equipmen*t1 Fittings
Fittings
Soka Factory Kamaishi
Air Dryers/Temperature Factory
Control Equipment Solenoid Valves Solenoid Valves
Air Line Equipment Air Line Equipment Air Line Equipment
Actuators Fittings
Asia Tono Factory
Asia Asia
India Factory Vacuum Equipment
Singapore Factory Actuators Flow Control Equipment Vietnam Factory
Fittings Flow Control Solenoid Valves
Air Dryers Equipment Sensors Fittings/Tubing
Auto Switches Actuators*1

Distribution Warehouse Risk Hedging Korea Central
Warehouse
U.S. Central Warehouse
Belgium East Japan Logistics Center
European Central Warehouse Automated warehouse introduction
West Japan
Germany Factory Scheduled to start operation in 2022 Logistics Center
(Image of completed building)
Under planning Construction in progress
China Logistics Center (Image of completed building)

Beijing, Shanghai, Guangzhou China Warehouse

Under planning

Technical Department BCP Sales Department BCP Management and (InAfoprpmlaictioanblSeectouriatyll
Finance Related BCP departments)
Global Engineering Network Established With 532 sales offices in 83 countries around the world
Other technical centers, working in parallel to each SMC provides support for customers with an 8700 Establishment of an advisory committee Strengthened information security with a globally
other can provide operational backups. person strong global sales force via SalesConnect (CRM) A strong financial foundation
Prevention of cyber attacks, automatic detection,
and strengthening of themonitoring systems.
Installation of data centers to establish
a disaster recovery system.

20


Click to View FlipBook Version