Published by capintec, 2018-02-24 17:50:06

EuroProbe3

EuroProbe3

EuroProbe3

Exceeding the Challenge of Radioguided Surgery

EuroProbe3

The EuroProbe3 meets the demanding specifications of EuroProbe3 Surgical Probe- Item #5250-0111
radioguided surgical procedures to identify increased EuroProbe3 Surgical Probe, (CdTe), Straight- Item #5250-0117
radionuclide uptake in a variety of clinical and surgical EuroProbe3 Surgical Probe, Cs(I), Bent- Item #5250-0118
settings. EuroProbe3 Surgical Probe, Cs(II), Straight- Item #5250-0119
EuroProbe3 Surgical Probe, CsI, High Sensitivity- Item #5250-0120
Multiple detector options, size and configurations have EuroProbe3 Surgical Probe, Endoscopic- Item #5250-0121
been designed to meet specific surgical requirements and Source Holder- Item #5250-0122
assure the versatility to perform optimal radioguided 511 Collimator, CsI- Item #5250-0125
surgical procedures. Collimator, CdTe- Item #5250-0112
Collimator, CSI- Item # 5250-0113
• Wireless EuroProbe3 Surgical Probe, CdTe, Bent- Item #5250-0116
EuroProbe3 with Bluetooth Probe- Item #5250-0152
• Blue Tooth probe: EuroProbe3 Bluetooth 511 Collimator - Item # 5250-0153
• 100 keV to 1 MeV (Tc-99m, In-111, I-131, F-18) Surgical Probe Sheath- Item #5250-0094
• Collimator integrated in the probe EuroProbe3 Source Holder- Item # 5230-2124
• Detector crystal: Csl

• Wired

• Large CsI probe:
• 110keV to 1 MeV
• Straight or angled probes

• High sensitivity straight or angled probes available

• Small CdTe probe:
• 20 keV to 170 keV
• Straight, angled, ROLL or endoscopic probes
• Excellent spatial resolution

SPECIFICATIONS EuroProbe3 Specifications

Detector Features

• High efficiency solid state scintillation detectors operating Operating Power:

at room temperature. • 115VAC, F=50Hz, I= 0.5A or 230VAC, F=50HZ, I= 0.250A

• High sensitivity and target to background ratio. Power Consumption:
• Hot swappable. • Max. 15 watts
• Can be sterilized with Ethylene Oxide gas. Maximum Counting Rate:
• Preferred ergonomic angled design. • 15,000 cps/s
• Integrated tungsten collimator. Operating Temperature Range:
• Additional detachable collimator is available. • +15°C to +40°C
• All probes are waterproof. Dimensions:

Detector Features • 245mm H x 233mm W x 270 mm D
Weight:
• Direct read-out (digital and bar-graph type) through large, • 4.4 lb. (2 kg)
easy to read display.

• Pre-set or user definable energy window setting for

ultimate flexibility.

• Choice of two types of audible signals proportional to

counting rate.

• Both probes are standard.

• Easily switch between probes.

• Store up to 9 custom configurations.

• Built in background subtraction.

• Choice of bent or straight probes.

• Automatic probe identification

• Optional foot switch.

OPTIONAL COMPONENTS

Bluetooth Probe Specifications CsI probe: “large” probe

Detector: Scintillator:
• Detector Crystal: CsI 10mm long x 5mm diameter coupled to a 25mm² silicon • Diameter = 5 mm, Length = 10mm CsI (T1) crystal coupled to a 25 mm2
Silicon photodiode Energy Range:
photodiode • 100 keV to 1 MeV
Energy Range: Dectector Efficiency for Tc-99m (140keV):
• 100 keV to 1 MeV (Tc-99m, In-111, I-131, F18) • > 80%
Probe Dimensions: Dectector Efficiency for In-111 (245 keV):
• Probe Length 261 mm Diameter 11 mm • > 70%
Collimation: Detector Efficiency for I-131 (364 keV):
• The collimator is integrated in the probe • > 45%
Weight: Storage Temperature:
• 200g • +1°C to +50°C
Protection IP: Operating Temperature Range:
• IP64 • +15°C to +50°C
Probe Battery: Final Size of the Probe:
• Pile Li-SOCL² 1/2AA 3,6V SAFT LS 14250 • Length = 184mm, detection head diameter = 16 mm. Slightly angled to permit easier
Wireless Connection:
• Module Bluetooth ID: ES9LMX9838 access certain tissues. The collimator is an integral part of the probe.
Decontamination: Weight:
• By Immersion, ONLY AFTER THE BATTERY HAS BEEN REMOVED • 6.2 oz. (175 g) (excluding table)
Maximum ambient humidity for good operation:
CdTe or CdZnTe probe: “small”J139 probe • 80% at 40°C

Semiconductor crystal either CdTe or CdZnTe:
• 5x5x3mm3 CdTe or CdZnTe (Cadmium Telluride)
Energy Range:
• 20 to 300 keV (can also be used from 170 to 364 keV, but the detection efficiency

within this range is better with the CsI probe)
Detector efficiency for I-125 (27-35 keV):
• > 80%
Dectector efficiency for Tc- 99m (140 keV):
• > 60%
Storage Temperature:
• +1°C to +40°C
Operating Temperature Range:
• +15°C to +40°C
Final Size of the Probe
• Length = 175mm, detection head diameter = 11 mm. Slightly angled to

permit easier access to certain tissues. The collimator is an integral part of the probe.
Weight:
• 5 oz. (140 g) (excluding cable)
Maximum ambient humidity for good operation:
• 80% at 40°C

6 Arrow Road, Ramsey, NJ 07446 • 201.825.9500 or 800.631.3826 • www.capintec.com
and Capintec are registered trademarks of Capintec, Inc.


Click to View FlipBook Version