CRC-15 Series Communications (with F18 key) Manual- Revision E

CRC®-15 Series
Communications

OWNER’S MANUAL

Capintec, Inc.
Sales and Marketing
and Customer Support

6 Arrow Road
Ramsey, NJ 07446
Phone (800) ASK-4CRC
Fax (201) 825-1336

Capintec, Inc.
Service Center
620 Alpha Drive
Pittsburgh, PA 15238
Phone (800) 227-6832
Fax (412) 963-0610

Copyright© 2002 Capintec, Inc.

®CRC is a registered trademark of Capintec, Inc.
U.S. Patents - 3,748,476 and 3,840,745
ALL RIGHTS RESERVED

Manual Stock No. 9250-0096

Rev. E – October 2007



CAPINTEC, INC. CRC®-15 Series Communications

TABLE OF CONTENTS

INTRODUCTION ...................................................................................................................... 3

INSTALLING THE SOFTWARE ..............................................................................................5

CONNECTING THE CALIBRATOR ........................................................................................9

DEMONSTRATION MODE......................................................................................................9

STARTING THE PROGRAM ...................................................................................................9
Data Acquisition..................................................................................................................10
Repeated Acquisition..........................................................................................................11
Maximum Activity Acquisition .............................................................................................11
Setup ..................................................................................................................................11

PROGRAM SETUP................................................................................................................12
Calibrator Frame.................................................................................................................12
License Frame ....................................................................................................................13
Entering the License .......................................................................................................13
Report Header Frame.........................................................................................................13
Communications Port Frame ..............................................................................................13
Exiting Program Setup........................................................................................................13

DATA ACQUISITION.............................................................................................................14
Standard Data Acquisition Screen......................................................................................14
Enhanced Data Acquisition Screen ....................................................................................15
User Key Names .............................................................................................................15
Changing Nuclide............................................................................................................16
Update User Keys ...........................................................................................................16
CRC®-15PET Dual Chamber Data Acquisition Screen ......................................................16
Select Chamber Frame ...................................................................................................16
Saving Data ........................................................................................................................17
Printing ...............................................................................................................................17
Exporting............................................................................................................................. 18
Exiting Data Acquisition ......................................................................................................18

REPEATED ACQUISITION ...................................................................................................19
Setup for Repeated Acquisition ..........................................................................................19
Entering Interval ..............................................................................................................20
Number of Measurements...............................................................................................20
Exiting Repeated Acquisition Setup ................................................................................20
Starting Repeated Acquisition ............................................................................................20
Canceling Repeated Acquisition.........................................................................................21
Printing ...............................................................................................................................21
Exporting............................................................................................................................. 21
Exiting Repeated Acquisition ..............................................................................................22

October 07 1

CAPINTEC, INC. CRC®-15 Series Communications

MAXIMUM ACTIVITY ACQUISITION ................................................................................... 22
Setup for Maximum Activity Acquisition ............................................................................. 23
Entering Interval.............................................................................................................. 23
Exiting Maximum Activity Setup...................................................................................... 23
Starting Maximum Activity Acquisition................................................................................ 23
Stopping Maximum Activity Acquisition .............................................................................. 23
Printing ............................................................................................................................... 24
Exporting ............................................................................................................................ 24
Exiting Maximum Activity Acquisition ................................................................................. 25

IMPORTING A FILE INTO EXCEL........................................................................................ 25

INDEX .................................................................................................................................... 29

NEW PRODUCT WARRANTY .............................................................................................. 31

2 October 07

CAPINTEC, INC. CRC®-15 Series Communications

INTRODUCTION

The CRC®-15 Series Communications Program will communicate with the following
calibrators that have the RS-232 option installed:

• CRC®-15R, CRC®-15R Enhanced,
• CRC®-15PET, CRC®-15PET Enhanced
• CRC®-15 Dual PET
• CRC®-15BT

It will also communicate with the Chamber portion of the following calibrators that have the
RS-232 option installed:

• CRC®-15 Beta, CRC®-15 Beta Enhanced
• CRC®-15W, CRC®-15W Enhanced

The functions supported by each calibrator are given in the table below.

Function 15R 15R Enhanced 15PET 15 15BT
Data Acquisition 15PET 15Beta Enhanced Enhanced Dual n
15Beta PET
Select Isotope 15W 15W Enhanced n
Acquire and Store Data n n
Daily Test n n n n
Repeated Acquisition n n n
Maximum Activity Acquisition n n n
Chamber Selection n n
n

October 07 3



CAPINTEC, INC. CRC®-15 Series Communications

INSTALLING THE SOFTWARE

Note: Before proceeding, it is recommended that you close any applications you may be
running. Setup cannot install system files or update shared files if they are in use.

Insert the CRC®-15 Series Communications CD into your CD drive.
The CD is self-starting. If it does not start, perform the following steps:

Select Run… from the Start Menu.
Click the Browse… button.
From the Look in: drop-down list, select Communications (CD Drive).
Click on the file setup.exe to select it.
Click the Open button.
Click the OK button.
The CRC®-15 Series Communications Setup window appears as shown in Figure 1.

Figure 1

Click the Exit Setup button to cancel the installation.
Click the OK button to continue the installation. Figure 2 will appear.

October 07 5

CAPINTEC, INC. CRC®-15 Series Communications

Figure 2
Click the Exit Setup button to cancel the installation.

Click the button to begin the installation. The CRC®-15 Series Comm F18 – Choose

Program Group window appears as shown in Figure 3.

Figure 3
Click the Cancel button to cancel the installation.
Click the Continue button to continue the installation. The Program begins to run through its
setup procedure as shown in Figure 4.

6 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Figure 4
Once Setup is completed successfully, Figure 5 will appear.

Figure 5
Click the OK button to finish the installation.
After the installation is complete, click the Start Menu, Programs, right-click on the CRC-15
Series Comm F18 icon and select Create Shortcut.
Drag one of the shortcuts to the Desktop.
Restart the computer.

October 07 7



CAPINTEC, INC. CRC®-15 Series Communications

CONNECTING THE CALIBRATOR

Connect one end of the cable to the “RS-232” port on the rear panel of the Calibrator.
Connect the other end of the cable to the Serial (Comm) port of the computer.

The calibrator must be connected to the PC and on the Chamber measurement screen
before starting the Communications program.

DEMONSTRATION MODE

Until you have purchased a license for the program, the program will run in Demonstration
Mode.

Reference License Frame on page 14 for information on obtaining a license.

The program will operate as if connected to a CRC®-15R Enhanced Calibrator but no
measurements can be obtained from a calibrator and no data can be saved, printed or
exported.

A pre-determined isotope and activity will be displayed.

STARTING THE PROGRAM

Double-click the desktop icon created during the installation procedure to start the CRC®-15
Communications program. Figure 6 Main Screen will appear.

All functions are accessed from the Main Screen.

October 07 9

CAPINTEC, INC. CRC®-15 Series Communications

Figure 6 Main Screen

From the Main screen, the following functions can be accessed:
• Data Acquisition
• Repeated Acquisition
• Maximum Activity Acquisition
• Setup

Note: The Repeated Acquisition and the Maximum Activity Acquisition buttons are inactive
(grayed out) on the Main Screen for the CRC®-15BT Calibrator.

Data Acquisition
(Reference DATA ACQUISITION on page 14 for operational instructions.)
The activity and isotope are displayed and updated every second. Selected measurements
may be saved and saved data may be printed or exported to Excel.

10 October 07

CAPINTEC, INC. CRC®-15 Series Communications

If your calibrator is a CRC®-15R Enhanced, CRC®-15 Beta Enhanced or CRC®-15W
Enhanced, the Isotope and User keys will be displayed on the Data Acquisition screen. The
isotope may be changed from the PC and the User keys will display the assigned isotope (for
any other calibrator, the Isotope and User keys are not shown).

If your calibrator is a CRC®-15R Enhanced, CRC®-15 Beta Enhanced, CRC®-15W Enhanced
or CRC®-15PET Enhanced, the Data Acquisition function can also display the readings from
the following tests:

• Daily (which consists of the Zero, Background, System, Accuracy and Constancy
tests)

• System
• Accuracy
• Background

The readings are displayed and updated every second.

Repeated Acquisition
Note: Repeated Acquisition is not available for the CRC®-15BT Calibrator.

(Reference REPEATED ACQUISITION on page 19 for operational instructions.)

The isotope and activity are displayed and updated at time intervals set by the user and for
the number of measurements set by the user. The data for each interval are automatically
saved and may be printed or exported to Excel.

Maximum Activity Acquisition
Note: Maximum Activity Acquisition is not available for the CRC®-15BT Calibrator.

(Reference MAXIMUM ACTIVITY ACQUISITION on page 22 for operational instructions.)

The isotope and activity are displayed and updated at time intervals set by the user. The
maximum activity will also be displayed. The data acquisition must be stopped by the user.
The maximum activity will be automatically saved and may be printed or exported to Excel.

Setup
(Reference PROGRAM SETUP on page 12 for operational instructions.)

Used to select the calibrator, select the communications port that the calibrator is connected
to and input the information to be included on the report headers. The License Request Form
is generated here and License information is entered here.

October 07 11

CAPINTEC, INC. CRC®-15 Series Communications

PROGRAM SETUP

From the Main screen, click the Setup button. Figure 7 Setup Screen will appear.

Figure 7 Setup Screen

Calibrator Frame
Click the appropriate radio button for your calibrator. An Activation Code will appear in the
License frame at the top of the screen.
For a Standard calibrator (15R, 15W, 15Beta, 15PET, 15PET Enhanced, 15PET Dual
Chamber, 15BT) the Activation Code is related to your computer. The Serial Number box will
be grayed out and blank.
For an Enhanced calibrator (15R Enhanced, 15W Enhanced, and 15Beta Enhanced) the
Activation Code is the last 4 digits of the calibrator serial number. The Serial Number box will
display the serial number of the calibrator.
Note: Remember that the program only communicates with the Chamber portion of the

CRC®-15Beta, CRC®-15Beta Enhanced, CRC®-15W and CRC®-15W Enhanced.

12 October 07

CAPINTEC, INC. CRC®-15 Series Communications

License Frame

After the Calibrator has been selected, the License Request Form button will be enabled. An
example activation code is shown below in Figure 8.

Figure 8 License Frame

Click the License Request Form button to print a form containing the information necessary
to obtain a license. Contact the Capintec Sales department at 1-800-631-3826 to order your
license. You will be given a License code that will work only with your computer/calibrator.

Note: A printer attached to your computer is required to obtain the License Request Form.

Entering the License
Note: If you have exited Setup before entering the license, you will still be in
Demonstration Mode. Re-enter Setup and click the appropriate radio button
for your calibrator.

Enter the License Code making sure that you enter the License with upper case
letters. If the license is correctly entered, you will be able to obtain data from the
calibrator.

Communications Port Frame

Comm 1 is set as the default. If there is more than one RS-232 port on your computer and
you want to use another port for communications with the calibrator, select another port. The
port will be set up when the Done button is pressed.

Report Header Frame

Up to 40 characters per line may be entered in these 5 fields. The Report Header will be
printed on all of the reports.

Exiting Program Setup
To exit Setup and save the entries, click the Done button.

To exit Setup without saving entries, click the Cancel button.

October 07 13

CAPINTEC, INC. CRC®-15 Series Communications

DATA ACQUISITION

From the Main screen, click the Data Acquisition button. There are 3 different Data
Acquisition screens depending on your calibrator:

• Standard Data Acquisition screen (15R, 15W, 15Beta, 15PET, 15PET Enhanced,
15BT) shown in Figure 9.

• Enhanced Data Acquisition screen (15R Enhanced, 15W Enhanced, 15Beta
Enhanced,) shown in Figure 10.

• CRC®-15PET Dual Chamber Data Acquisition screen (15PET Dual Chamber) shown
in Figure 11.

Note: Remember that the program only communicates with the Chamber portion of the
CRC®-15Beta, CRC®-15Beta Enhanced, CRC®-15W and CRC®-15W Enhanced.

The isotope and activity are automatically acquired every second. Data Acquisition begins
when the Data Acquisition screen is displayed. The current calibrator reading is displayed.

Standard Data Acquisition Screen

The Standard Data Acquisition screen is displayed when using one the following calibrators:
CRC®-15R, CRC®-15W, CRC®-15Beta, CRC®-15PET, CRC®-15PET Enhanced and CRC®-
15BT.

Figure 9 Standard Data Acquisition Screen

14 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Enhanced Data Acquisition Screen

The Enhanced Data Acquisition screen is displayed when using one the following calibrators:
CRC®-15R Enhanced, CRC®-15W Enhanced and CRC®-15Beta Enhanced.

The Enhanced Data Acquisition function can also display readings from the following tests:

• Daily (which consists of the Zero, Background, System, Accuracy and Constancy
tests)

• System
• Accuracy
• Background

Figure 10 Enhanced Data Acquisition Screen

User Key Names
When the Enhanced Data Acquisition screen is accessed, the Calibrator sends the
names of the isotopes assigned to the User Keys to the PC. These names are
displayed on the User keys on the Enhanced Data Acquisition screen. If a User Key
does not have a isotope assigned to it, the key will not be active (grayed out).

October 07 15

CAPINTEC, INC. CRC®-15 Series Communications

Changing Nuclide

The isotope on the calibrator can be changed from the PC program by clicking one of
the Pre-Set Isotope keys or a User key shown on the Enhanced Data Acquisition
screen. The data for the selected isotope will be displayed.

Update User Keys
If the assignment for any User key on the calibrator is changed, click the Update
User Keys button so that the User keys on the PC program will reflect the
assignments on the calibrator.

CRC®-15PET Dual Chamber Data Acquisition Screen
The CRC®-15PET Dual Chamber Data Acquisition screen is displayed when using the
CRC®-15PET Dual Chamber Calibrator.

The isotope and activity are automatically acquired every second for the selected Chamber.

Figure 11 CRC®-15PET Dual Chamber Data Acquisition Screen
Select Chamber Frame

To change the Chamber being read, click on the appropriate radio button for
Chamber #1 or #2.

16 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Saving Data
To save data for printing or exporting, click the SAVE button. The data will appear in the
Saved Isotope and Activity boxes at the top of the screen.

Each time the SAVE button is pressed, the current data is added to the previously saved
data.

Once the DONE button is pressed, the saved data is erased.

If you wish to retain the saved data, you must either print it or export it to a file. The Print and
Export buttons will become active after the SAVE button is pressed.

Printing
Note: The Print button is not active until the SAVE button is pressed.

Click the Print button for a printout of the saved data. After printing, you will be asked if you
want to retain the data. Click the Yes button to retain the data.

If the No button is pressed, all saved data will be erased and the Print button will become
inactive.

October 07 17

CAPINTEC, INC. CRC®-15 Series Communications

Exporting
Note: The Export button is not active until the SAVE button is pressed.

Click the Export button to create a file of the saved data that may be used in Excel or a
similar program. (The default save folder is C:\CRC-15 Series Communications\Data. The
default file extension is .xls) Figure 12 Default Extension is xls Screen will appear.

Figure 12 Default Extension is xls Screen

Type a name in the File name: drop-own box and press the Save button.
After exporting, you will be asked if you want to retain the data. Click the Yes button to retain
the data.
If the No button is pressed, all saved data will be erased and the Export button will become
inactive.

Exiting Data Acquisition
Click the DONE button or press the Esc key to exit the Data Acquisition screen and return to
Figure 6 Main Screen.
All saved data will be erased upon exiting the Data Acquisition screen.

18 October 07

CAPINTEC, INC. CRC®-15 Series Communications

REPEATED ACQUISITION

Repeated Acquisition is used to acquire data at a constant time interval for a given number of
measurements.

Note: Repeated Acquisition is not available for the CRC®-15BT Calibrator.

Note: Remember that the program only communicates with the Chamber portion of the
CRC®-15Beta, CRC®-15Beta Enhanced, CRC®-15W and CRC®-15W Enhanced.

From the Main screen, click the Repeated Acquisition button. Figure 13 Repeated
Acquisition Screen will appear.

Note: The Repeated Acquisition screen for the CRC®-15PET Dual Chamber Calibrator
contains a Select Chamber Frame used to change the chamber being read; click the
appropriate radio button for Chamber #1 or #2.

Standard/Enhanced CRC®-15PET Dual Chamber

Figure 13 Repeated Acquisition Screen

Setup for Repeated Acquisition
Click the Setup button to display Figure 14 Repeated Acquisition Setup Screen.

The Setup screen is used for entering the parameters needed to acquire repeated data.

October 07 19

CAPINTEC, INC. CRC®-15 Series Communications

Figure 14 Repeated Acquisition Setup Screen

Entering Interval
The default value for the interval between measurements is 1 second.
To change this value, input the desired interval in seconds, minutes or hours (integral
seconds, minutes or hours only).

Number of Measurements
Input the desired number of measurements. The Total Acquisition time will then be
displayed.

Exiting Repeated Acquisition Setup
Click the Done button to exit Repeated Acquisition Setup and save the values.
Click the Cancel button to exit Repeated Acquisition Setup without saving the values.
Figure 13 Repeated Acquisition Screen will re-appear.

Starting Repeated Acquisition
Click the Start button to begin the acquisition.
Data is read from the calibrator at the requested interval for the requested number of
measurements. The Isotope, Activity and Acquisition number are displayed.
When the acquisition is complete, the time, Isotope and Activity for each measurement are
saved for output and the Export and Print buttons become active.

20 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Canceling Repeated Acquisition
Click the Cancel button to stop the acquisition before all of the requested measurements
have been made.

Printing
Click the Print button for a printout of the measurements. After printing, you will be asked if
you want to retain the data. Click the Yes button to retain the data.

If the No button is pressed, all saved data will be erased and the Print button will become
inactive.

Exporting
Click the Export button to create a file of the measurements that may be used in Excel or a
similar program. (The default save folder is C:\CRC-15 Series Communications\Data. The
default file extension is .xls) Figure 15 Default Extension is xls Screen will appear.

Figure 15 Default Extension is xls Screen

Type a name in the File name: drop-own box and press the Save button.
After exporting, you will be asked if you want to retain the data. Click the Yes button to retain
the data.

If the No button is pressed, all saved data will be erased and the Export button will become
inactive.

October 07 21

CAPINTEC, INC. CRC®-15 Series Communications

Exiting Repeated Acquisition
Click the Done button or press the Esc key to exit the Repeated Acquisition screen.

All saved data will be erased upon exiting the Repeated Acquisition screen.

MAXIMUM ACTIVITY ACQUISITION

Maximum Activity Acquisition is used to perform repeated data acquisitions and save the
maximum activity for the set acquisition time period.

Note: Maximum Activity Acquisition is not available for the CRC®-15BT Calibrator.

Note: Remember that the program only communicates with the calibrator portion of the
CRC®-15Beta, CRC®-15Beta Enhanced, CRC®-15W and CRC®-15W Enhanced.

From Figure 6 Main Screen, click the Maximum Activity Acquisition button. Figure 16
Maximum Activity Acquisition Screen will appear.

Note: The Maximum Activity Acquisition screen for the CRC®-15PET Dual Chamber
Calibrator contains a Select Chamber Frame used to change the chamber being
read; click the appropriate radio button for Chamber #1 or #2.

Standard/Enhanced CRC®-15PET Dual Chamber

Figure 16 Maximum Activity Acquisition Screen

22 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Setup for Maximum Activity Acquisition
Click the Setup button to display Figure 17 Maximum Activity Setup Screen.

Figure 17 Maximum Activity Setup Screen

Entering Interval
The default value for the interval between measurements is 1 second.

To change this value, input the desired interval in seconds (integral seconds only)

Exiting Maximum Activity Setup
Click the Done button to exit Maximum Activity Setup and save the values.

Click the Cancel button to exit Maximum Activity Setup without saving the values.

Figure 16 Maximum Activity Acquisition Screen will re-appear.

Starting Maximum Activity Acquisition
Click the Start button to begin the acquisition.

Data will be read from the Chamber at the requested interval. The Isotope, Maximum Activity
since the data acquisition began and the Current Activity will be displayed. The Run Time
(time since the data acquisition began) will also be displayed.

Stopping Maximum Activity Acquisition
Click the Stop button to terminate the Maximum Activity Acquisition and save the maximum
activity.

When the acquisition is stopped, the time, Isotope and Maximum Activity are saved for
output and the Export and Print buttons become active.

October 07 23

CAPINTEC, INC. CRC®-15 Series Communications

Printing
Click the Print button for a printout of the maximum activity for each set of measurements.
After printing, you will be asked if you want to retain the data. Click the Yes button to retain
the data.

If the No button is pressed, all saved data will be erased and the Print button will become
inactive.

Exporting
Click the Export button to create a file of the maximum activities that may be used in Excel
or a similar program. (The default save folder is C:\CRC-15 Series Communications\Data.
The default file extension is .xls) Figure 18 Default Extension is xls Screen will appear.

Figure 18 Default Extension is xls Screen

Type a name in the File name: drop-own box and press the Save button.
After exporting, you will be asked if you want to retain the data. Click the Yes button to retain
the data.
If the No button is pressed, all saved data will be erased and the Export button will become
inactive.

24 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Exiting Maximum Activity Acquisition
Click the Done button or press the Esc key to exit the Maximum Activity Acquisition screen.

All saved data will be erased upon exiting the Repeated Acquisition screen.

IMPORTING A FILE INTO EXCEL

Data that has been exported to Excel is in a format that is easy for Excel to read. However, a
few steps must be performed before accessing the data.

1. Open Excel and select the exported file (15test3.xls in the example). Figure 19 will
appear.

Figure 19

2. Verify that the Delimited radio button is selected and the File origin: drop-down box is
set to Windows (ANSI). Click the Next> button. Figure 20 will appear.

October 07 25

CAPINTEC, INC. CRC®-15 Series Communications

Figure 20
3. Verify that the options are set as above. Click the Next> button. Figure 21 will appear.

Figure 21
4. Click the Finish button. The spreadsheet will appear as shown in Figure 22.

26 October 07

CAPINTEC, INC. CRC®-15 Series Communications

Figure 22

5. If you want a heading for the data, highlight the first row and select Rows from the
Insert Menu. Refer to Figure 23.

Figure 23

6. Type the heading in the row that is opened in front of the current row 1. Refer to
Figure 24.

October 07 27

CAPINTEC, INC. CRC®-15 Series Communications

Figure 24

28 October 07

CAPINTEC, INC. CRC®-15 Series Communications

INDEX

A Interval
activation code, 13 entering, 20, 23

C L
Calibrator Frame, 12 License
Calibrator Functions, 3
Changing Nuclide, 16 entering, 13
Communications Port, 13 obtaining, 13
Connection
M
Calibrator, 9 Maximum Activity Acquisition, 11, 22

D Entering Interval, 23
Data Acquisition, 10, 14 Exiting, 25
Exiting Setup, 23
CRC®-15PET Dual Chamber screen, 16 Exporting, 24
Enhanced screen, 15 Printing, 24
Exiting, 18 Setup, 23
Exporting, 18 Starting, 23
Printing, 17 Stopping, 23
Saving Data, 17
Standard screen, 14 N
Demo Mode, 9 Nuclide
Demonstration Mode, 9
change, 16
E Number of Measurements, 20
Excel
P
Importing a file, 25 Printing
Exiting
Data Acquisition, 17
Data Acquisition, 18 Maximum Activity Acquisition, 24
Maximum Activity Acquisition, 25 Repeated Acquisition, 21
Maximum Activity Acquisition Setup, 23 Program Setup, 12
Program Setup, 13 Program Setup
Repeated Acquisition Setup, 20 exiting, 13
Exporting
Data Acquisition, 18 R
Maximum Activity Acquisition, 24 Repeated Acquisition, 11, 19
Repeated Acquisition, 21
Canceling, 21
F Entering Interval, 20
Functions Exiting, 22
exiting setup, 20
Calibrator, 3 Exporting, 21
Program, 10 Number of Measurements, 20
Printing, 21
I Setup, 19
Importing to Excel, 25 Starting, 20
Installation, 5 Report Header, 13

October 07 29

CAPINTEC, INC. CRC®-15 Series Communications

S Repeated Acquisition, 19
Saving Data Starting the Program, 9

Data Acquisition, 17 U
Select Chamber Frame, 16, 19, 22 User Key
Setup, 11
Names, 15
Maximum Activity Acquisition, 23 Update, 16
Program, 12

30 INDEX November 03

NEW PRODUCT WARRANTY

Conditions and Limitations

CAPINTEC warrants our products to be free from defects in material and
workmanship for a period of 12 months after delivery to the original buyer
(unless indicated otherwise). Our obligation under this warranty is
limited to servicing or adjusting products returned to our factory for that
purpose promptly upon any claim under this warranty, provided our
examination discloses to our satisfaction that the affected parts were
originally defective and have not been subjected to misuse, abuse,
mishandling or improper operation. This warranty extends to every part
of the product except batteries, fuses, ink, magnetic storage media,
toner, transistors, tubes or any other normally consumable item. In no
event shall we liable for transportation, installation, adjustment or any
other expenses which may arise in connection with such products or
their servicing or adjustment.

This warranty is expressly in lieu of any other express or implied
warranties, and we make no warranty that the products sold herein are
merchantable or are suitable for any particular purpose. The benefits of
this warranty shall extend only to the buyer and to none other. We shall
have no liability of any nature arising out of the use or application of the
product in conformity with this warranty. If the product shall fail to
perform in conformity with the warranty made herein, we shall be liable
solely for the repair and replacement of the product as provided
hereinabove, and shall have no other liability in respect of such failure or
performance, or any consequences therefrom, including, without
limitation, business impairment or loss, personal injury or property
damage.

No agent, employee, or representative of ours has any authority to bind
us to any representation or warranty concerning the product sold herein,
and unless a representation or warranty made by an agent, employee or
representative is specifically included herein, it shall not be enforceable
by the buyer. No waiver, alteration or modification of the foregoing
conditions shall be valid, unless made in writing and signed by an
executive officer of our corporation.


Click to View FlipBook Version