Captus ® 700t Thyroid Uptake System Brochure

Captus®700t Thyroid Uptake System

Fast, Accurate, High Quality at Low Cost! Diagnostics and Tests:
• Quality Assurance includes zero adjust, automatic gain adjust,
With the Captus® 700t Thyroid Uptake System and its new
color touch screen interface, performing thyroid uptake mea- calibrator detector resolution, Chi-square, constancy, MDA,
surements has never been easier. automatic efficiency calculation and storage.
Using HIPAA compliant software, the Captus 700t provides fast, • Thyroid Uptake protocols allow entry of patient demographics
dedicated modules for Thyroid Uptake, Wipe Tests, Bio-Assay, and the selection of a pre-defined procedure protocol. The stan-
and Lab Tests including Schillings Test, Blood Volume, and dard can be measured with each uptake or automatically decay-
RBC Survival. corrected by the software. The number of uptakes for each
QA is automated and easy to perform for calibration, constancy, patient procedure is user-defined. The Captus 700t software
Chi Square, MDA and resolution functions. System calibration, will automatically calculate and store each uptake which will be
constancy and Chi-Square are automatically performed using a available for immediate access/printing or may be retrieved at
Cs-137 reference source. Eu-152 can be used for enhanced the conclusion of the study or at a later point in time.
point to point spectral energy calibration. The General • Wipe Testing is state-of-the-art and uses a simple menu-driven
Measurement software is very user friendly. ROI's can be format. The system will perform a peak search on each wipe
selected from a convenient menu of isotopes with pre-defined sample and will identify any contamination by peak and by
regions, or, ROI's can defined by the user. Results are reported nuclide. The user determines and defines the number of wipe
with full spectrum counts and counts by region of interest. locations. Wipe locations can be grouped by a variety of vari-
Multiple TU protocols can be created for I-123, I-131 or Tc-99m. ables including wipe location and type. Pre-defined or user-
The protocols can use a standard capsule method or allow the defined trigger levels are set to flag wipes above a specific
system to perform an automatic decay correction to the admin- activity level.
istered dose. The system will store detailed patient demograph- • Lab tests including Schillings Test and I-125 or Cr-51 Blood
ics, physician data and administered dose data. There is no Volume offers step-by-step guidance through the counting pro-
limit to the number of uptakes that can be cedure and automatic calculation of the results. Patient demo-
performed, and the results will be reported graphics and procedure results are printed or archived, as
with detailed count information and automatic
percentage uptake calculations. necessary.
• Red Blood Cell Survival is an added
feature and provides the same step-by-
step guidance through the counting
procedure and automatic calculation of
results.
• Bioassay for Staff allows for the quick
and efficient assessment of potential
thyroid burden for I-123, I-125 or I-131.
Staff records, as with other test results,
are maintained and archived on the
instrument or available as printed
records.

Thyroid Uptake Stand Dimensions
• Height: 69" (175.3 cm)
• Width: 28" (71.1 cm)
• Depth: 31" (78.7 cm)
• Weight: 400 lbs (181.8 kg)
• w/optional well: 470 lbs (213.6 kg)

Captus ®700t Thyroid Uptake System: Item #5430-3137 Console Dimensions
Captus ®700t Thyroid Uptake System • Height: 9.5" (42 cm)
• Width: 9" (23 cm)
with Well: Item #5430-3138 • Depth: 10.5" (27 cm)
Optional 2 inch Shielded Well: Item #5430-0069 • Weight: 7.5 lb. (3.4 kg)

CAPINTEC, INC. 6 Arrow Road, Ramsey, NJ 07446 · PH: 201.825.9500 or 800.631.3826 · WEB: www.capintec.com

Captus®700t Thyroid Uptake System

Display Screen • Maximum Count Rate - 100,000 counts per second (Real Time)
• Type: 8” VGA LCD Color Touch Screen Display • Linear Display - Automatic/Manual
• Patient Demographics
• Test Results Nuclide Data
• Spectral Display • Over 90 Nuclides in Memory (major gamma-ray energies, keV and

Detector half-life)
• 2” x 2” shielded NaI (TI) crystal with standard or optional
Pediatric/Bioassay collimator Advanced System Setup
• Test Sources, Efficiencies, User Nuclides, Wipe Test Data,
Well Detector Bioassay Data, Thyroid Uptake protocols, Thyroid Uptake Normal
• Optional drilled well type NaI (TI)- lined with brass to minimize Values
back scatter
1: Well Diameter: 1.6 cm max (5/8”) Diagnostics and Tests
Depth: 4 cm (1 1/2”) • Full system self-diagnostics including all program and data memories
Lead: 2.5 cm (1”) • Comprehensive test programs include automatic Chi-Square and
2: Well Diameter: 1.6 cm max (5/8”) FWHM, and MDA
Depth: 4 cm (1 1/2”)
Lead: 5 cm (2”) Printer
• Inkjet Color Printer
Multichannel Pulse Height Analyzer • Print results of studies including graphic displays
• 512 Channels
• Automatic self-calibration Thyroid Uptake Stand
• Linearity - within 2% full scale • Rugged floor stand with spring arm and shelves
• Differential Linearity - 2% SD • Heavy duty locking casters
• A to D conversion time - 10 microseconds • Base designed to hold Shielded Well Detector
• Low Energy Discrimination Level - 16 KeV, 4 Channels
(whichever is greater) Power Requirements
• ROI - Automatic or Manual • Standard: 115V .25A 90-127V 50-60Hz
• Background subtraction and mean energy calculation via curve • Optional: 220V .125A 180-250V 50-60HZ
fittings (With circuit protections, line filter and isolation transformer)

Optional Accessories

Neck Phantom: Wipe Spot Pads (Box of Test Tubes for Wipe Samples Table Top Stand: Well Detector (2” Shield):
Item #5230-0038 500): Item #5420-0086 (Qty. 100): Item #5420-0090 Item #5430-2038 Item #5230-0069

Eu-152- (0.5 µCi Rod): Rod Source Holder: Wall Mount Stand: Drilled Well Crystal:
Item #0975-152R Item #7315-1850 Item #5430-3095 Item #5430-0081
Cs-137- (0.5 µCi Rod):
Item #0975-137R

CAPINTEC, INC. 6 Arrow Road, Ramsey, NJ 07446 · PH: 201.825.9500 or 800.631.3826 · WEB: www.capintec.com