The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by capintec, 2018-03-03 14:15:48

Hot Cells Brochure

Hot Cells Brochure

7 Vreeland Road, Florham Park, NJ 07932
201.825.9500 or 800.631.3826 • www.capintec.com

Multiple Function Hot Cell • An innovative vacuum sealing technology ensures chamber air
tightness.
The multiple function hot cell has two operation platforms both
with lead glass viewing windows. One equipped with two shielded • A HEPA filter is equipped to ensure the air quality complies
glove ports, another equipped with one tong. It is available for two with Grade A (class 100/ISO 5).
operators to handle the isotope simultaneously. It is not only for
research purpose but also for GMP production. • The Smart Touch Control Panel integrates all operating
functions and real time monitoring of temperature, humidity,
air pressure, air flow rate, air change rate, and radiation level.

• It is perfect for daily production and also ideal for research
operations

DIMENSIONS
• External Size: W120 x D 120 x H270 cm
• Internal Size: W 96 x D 77 x H 65 cm
• Weight: 6800 kg (lead thickness 60mm on front side, and 50mm on back and

other sides.)

ITEM NUMBERS
Multiple Function Hot Cell (75/75 mm lead shielding).............. 5300-00001
Multiple Function Hot Cell (75/60 mm lead shielding).............. 5300-00002
Multiple Function Hot Cell (60/50 mm lead shielding).............. 5300-00003

2

All-In-One Hot Cell

It consists of dual synthesizing cell and a dispensing cell to save
space and cost, as well as comply with GMP guidelines. It is ideal
for upgrading or renovating your current laboratory to achieve
GMP requirement.

• The working chamber is SUS 316 stainless steel with rounded Smart Touch Control Panel
corners to minimize dust accumulation. The external surface is
SUS 304 stainless steel. DIMENSIONS
• External Size: W 180 x D 113 x H 270 cm
• 75 mm of lead shields the front of the hot cell. All other sides • Internal Size:
have 60 mm or 75 mm of lead shielding.
• Dispensing Chamber: W 60 x D 79 x H 70 cm
• The Laminar Flow Dispensing Chamber includes HEPA • Synthesis Chamber: W 70 x D 64 x H 65 cm
filtration that provides air quality to comply with Grade A (class • Weight: 11800kg
100/ISO 5).
ITEM NUMBERS
• Unidirectional air flow in the Synthesis Chambers have HEPA All-In-One Hot Cell (75/60/50 mm lead shielding)..................... 5730-00004
filtration to comply with class C or B (depending on the Lab All-In-One Hot Cell (75/75/60 mm lead shielding)..................... 5730-00005
environment) requirements. Exhaust air passes through charcoal
filtration.

• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.

• The Smart Touch Control Panel integrates all operating
functions and real time monitoring information.

• The front of the Dispensing Cell has a lead glass viewing
window and a tele-tong. The Synthesis Cells have a viewing
CCTV monitor on the upper shielded hinged door.

• A shielded sliding door located on the side of the Dispensing
Cell enables easy movement of material or products between the
cells.

• The Dispensing Cell has a side door with a shielded glove port.
An air ventilated lifter is equipped on the below of glove port to
ensure the material and product deliver in or out the clean air
chamber without cross contamination.

• Radiation detectors measure the level of activity in each
working chamber. When the radiation exceeds a preset safety
level the interlock system prevents the door from opening
(optional).

• It accommodates auto dispensers ADG-500 and ADG-500S.

3

Tele-Tong Hot Cell

It is equipped with two tele-tongs for handling and processing
isotope and radiopharmaceuticals under Grade A (Class 100/ ISO
5) environment to comply with GMP regulations.

• The working chamber is SUS 316 stainless steel with rounded
corners to minimize dust accumulation. The external surfaces
are SUS 304 stainless steel.

• 75 or 60 mm of lead shields the front of the hot cell. All other
sides have 75, 60 or 50 mm of lead shielding.

• The Laminar Flow Dispensing Chamber has HEPA filtration
that provides air quality to comply with Grade A (class 100/
ISO 5).

• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.

• The Smart Touch Control Panel integrates all operating
functions, real time monitoring information and readings from
the dose calibrator.

• The hinged front door has a lead glass viewing window.
• Two tongs enable manipulative work in the dispensing area.
• A product elevator enables materials or products to be moved

into and out of the dispensing area without contamination.
• A 60 mm lead dose calibrator housing is equipped below the

working level.
• A radiation detector measures the radioactivity level in the

working chamber. When the radiation exceeds a preset safety
level the interlock prevents the doors from opening (optional).
• It accommodates auto dispensers ADG-500, ADG-500S,
MVD-20, and APDS.

Smart Touch Control Panel

DIMENSIONS
• External Size: W 120 x D 130 x H 240 cm
• Internal Size: W 92 x D 87 x H 80 cm
• Weight: 7800 kg (75/60 mm lead shielding); 6800 kg (75/60/50 mm lead

shielding)

ITEM NUMBERS
Tele-Tong Hot Cell (75/60 mm lead shielding)............................ 5730-00006
Tele-Tong Hot Cell (75/60/50 mm lead shielding)...................... 5730-00007
Tele-Tong Hot Cell (75/75 mm lead shielding)............................ 5730-00008

4

Production Hot Cell

This hot cell is equipped with two shielded glove ports, one tele-
tong, and two lead glass viewing windows in the front. It is
available for two operators to handle the isotopes simultaneously. It
is not only for research purpose but also for GMP production.

• The working chamber is SUS 316 stainless steel with rounded
corners to minimize dust accumulation. The external surfaces
are SUS 304 stainless steel.

• 75 or 60 mm of lead shields the front of the hot cell. All other
sides have 75, 60 or 50 mm of lead shielding.

• The Laminar Flow Dispensing Chamber has HEPA filtration
that provides air quality to comply with Grade A (class 100/
ISO 5).

• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.

• The Smart Touch Control Panel integrates all operating
functions, real time monitoring information and readings from
the dose calibrator.

• The hinged front door has a lead glass viewing window.
• Two shielded glove ports and one tele-tong enable manipulative

work in the dispensing area.
• A air ventilated product elevator enable materials or products to

be moved into and out of the dispensing area without
contamination.
• A 60 mm lead dose calibrator housing is equipped below the
working level.
• A radiation detector measures the radioactivity level in the
working chamber. When the radiation exceeds a preset safety
level the interlock prevents the doors from opening (optional).
• It is ideal for accommodation auto dispenser MVD-20.

Smart Touch Control Panel

DIMENSIONS
• External Size: W 152 x D 120 x H 260 cm
• Internal Size: W 120 x D 75 x H 65 cm
• Weight: 7800 kg

ITEM NUMBERS
Production Hot Cell (75/60 mm lead shielding)......................... 5730-00009
Production Hot Cell (60/50 mm lead shielding)......................... 5730-00010
Production Hot Cell (77/75 mm lead shielding)......................... 5730-00011

5

Dispensing Hot Cell

This hot cell is for operators to handle the lower activity
radiopharmaceuticals or isotopes through two shielded glove ports
either by an automatic or semi-auto dispenser. It is ideal for PET
center or nuclear medicine department to dispense the
radiopharmaceuticals from bulk vial into syringes (unit does) in a
Grade A (class 100/ ISO 5) environment to comply with GMP.

• The working chamber is SUS 316 stainless steel with rounded
corners to minimize dust accumulation. The external surfaces
are SUS 304 stainless steel.

• The front face of the hot cell is shielded with either 75 or 60
mm of lead. All other sides have 75,60, or 50 mm of lead
shielding.

• The Laminar Flow Dispensing Chamber has HEPA filtration
that provides air quality to comply with Grade A (class 100/
ISO 5).

• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.

• The Smart Touch Control Panel integrates all operating
functions, real time monitoring information, and readings
from the dose calibrator.

• The hinged front door has a lead glass viewing port and two
shielded glove ports (the gloves are not shielded).

• Air ventilated elevator functioning in a class 100 environment
enable materials to be transferred into and out of the
dispensing area without contamination.

• A 60 mm lead dose calibrator housing is equipped below the
working level.

• A GM detector measures the radioactivity level in the working
chamber. When the radiation exceeds a preset safety level the
interlock prevents the doors from opening (optional).

• It accommodates auto dispenser ADG-2000.

Smart Touch Control Panel

DIMENSIONS
• External Size: W 113 x D 110 x H 240 cm (75/60 mm lead shielding); W 113

x D 110 x H 260 cm (75/60 or 50 mm lead shielding)
• Internal Size: W 88 x D 70 x H 70 cm
• Weight: 6500 kg

ITEM NUMBERS
Dispensing Hot Cell (75/60 mm lead shielding)......................... 5730-00012
Dispensing Hot Cell (60/50 mm lead shielding)......................... 5730-00013
Dispensing Hot Cell (75/75 mm lead shielding)......................... 5730-00014

6

Manipulator Hot Cell

Can be equipped with a pair of manipulators for handling and
processing the high activity isotopes or radiopharmaceuticals under
Grade A (class100/IOS 5) environment to comply with GMP
regulations.

• The working chamber is SUS 316 stainless steel with rounded
corners to minimize dust accumulation. The external surfaces
are SUS 304 stainless steel.

• The front face of the hot cell is shielded with either 60 or 75
mm of lead. All other sides have 50, 60, or 75 mm of lead
shielding.

• The Laminar Flow Dispensing Chamber includes HEPA
filtration that provides air quality to comply with Grade A
(class 100/ISO 5).

• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.

• The Smart Touch Control Panel integrates all operating
functions, real time monitoring information, and readings
from the dose calibrator.

• The hinged front door has a lead glass viewing window.
• A pair of manipulator is equipped for handling andprocessing

the isotope or radiopharmacy under Grade A condition
(optional).
• Air ventilated elevator functioning in a class 100 environment
enable materials to be transferred into and out of the
dispensing area without contamination.
• A 60 mm lead dose calibrator housing is equipped below the
working level.
• A GM detector measures the radioactivity level in the working
chamber. When the radiation exceeds a preset safety level the
interlock prevents the doors from opening (optional).
• It accommodates dispensers ADG-500, ADG-500S, MVD-20,
and APDS.

Smart Touch Control Panel

DIMENSIONS
• External Size: W 140 x D 130 x H 270 cm
• Internal Size: W 100 x D 80 x H 100 cm
• Weight: 8200 kg

ITEM NUMBERS
Manipulator Hot Cell (60/50 mm lead shielding)....................... 5730-00015
Manipulator Hot Cell (75/60 mm lead shielding)....................... 5730-00016
Manipulator Hot Cell (75/75 mm lead shielding)....................... 5730-00017

7

Dual Synthesis Hot Cell

This hot cell has two segregated cabinets to accommodate two
chemical modules (chemical synthesizer) in a vertical position. The
shielded side cabinet is ideal to enlarge the space for placing the
accessories of chemical modules or as a transfer box to delivery
material or product in/out the hot cell.

• The working chambers are SUS 316 stainless steel with
rounded corners to minimize dust accumulation. The external
surfaces are SUS 304 stainless steel.

• 75 mm of lead shields the face of the hot cell. All other sides
can be supplied with 60 mm or 75 mm lead shielding.

• A unidirectional air flow system in the synthesis chamber passes
through a HEPA filter to ensure compliance with classes C or
B (depending on the lab environment). Exhaust air passes
through a charcoal filter.

• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.

• The Smart Touch Control Panel integrates all operating
functions and real time monitoring information.

• Hinged front doors allow complete access to the working
chambers.

• A video monitor displays the output from a CCTV installed in
each cell.

• A GM detector measures the radioactivity level in the working
chamber. When the radiation exceeds a preset safety level the
interlock prevents the doors from opening (optional).

• The optional side chamber with 20 mm of lead shielding is
available as optional.

Smart Touch Control Panel

DIMENSIONS
• External Size: W 102 x D 107 x H 260 cm (75/60 mm lead shielding); W 150

x D 107 x H 260 cm (75/60 mm lead shielding with 20mm lead shielded side
chamber)
• Internal Size: W 72 x D 80 x H 100 cm (75/60 mm lead shielding); W 72 x D
65 x H 68 cm (75/60 mm lead shielding with 20mm lead shielded side
chamber)
• Weight: 8200 kg (75/60 mm lead shielding); 9000 kg (75/60 mm lead
shielding with 20mm lead shielded side chamber)
ITEM NUMBERS
Dual Synthesis Hot Cell (75/60 mm lead shielding)................... 5730-00018
Dual Synthesis Hot Cell (75/75 mm lead shielding)................... 5730-00019

8

Synthesizing Hot Cell

Its large interior space is designed to accommodate chemical
module (chemical synthesizer) and accessories, such as HPLC
detector. Two shielded boxes are equipped on front of the lower
level as for additional space or transfer box.
• The working chamber is SUS 316 stainless steel with rounded

corners to minimize dust accumulation. The external surfaces
are SUS 304 stainless steel.
• 75 mm of lead shields the face of the hot cell. All other sides
can be supplied with 60 mm or 75 mm lead shielding.
• A unidirectional air flow system in the synthesis chamber passes
through a HEPA filter to ensure compliance with classes C or
B (depending on the lab environment). Exhaust air passes
through a charcoal filter.
• An innovative air vacuum technology system seals the inner
containment door to ensure air tightness.
• The Smart Touch Control Panel integrates all operating
functions, real time monitoring information, and readings
from the dose calibrator.
• Two over lapping hinged doors allow full access to the working
chamber.
• A GM detector measures the radioactivity level in the working
chamber. When the radiation exceeds a preset safety level the
interlock prevents the doors from opening (optional).
• A video monitor displays the output from CCD cameras
installed in the cell.

Smart Touch Control Panel

DIMENSIONS
• External Size: W 112 x D 105 x H 260 cm
• Internal Size: W 85 x D 70 x H 70 cm
• Weight: 6800 kg
ITEM NUMBERS
Synthesizing Hot Cell (75/60 mm lead shielding)....................... 5730-00020
Synthesizing Hot Cell (75/75 mm lead shielding)....................... 5730-00021

9

Solid Target Hot Cell

The Solid Target Hot Cells consist of a hot cell for processing and a
hot cell for production. The hot cell for processing is for the
chemical synthesizer and equipped a disc receiving carrier. The hot
cell for production is equipped with an auto pipette dispensing
system to heat, shake and dispense the isotopes into micro liter
vials.

Auto Micropippette Dispenser
ITEM NUMBERS
Solid Target Hot Cell 75/60 mm.................................................... 5730-00024
Solid Target Hot Cell 75/60 mm, 75/60 mm with 20 mm
Lead Shielding................................................................................. 5730-00025

10

Bio-Safety Cabinet

As a leading manufacturer of shielded enclosures for a variety of
Nuclear Medicine, PET and 511 SPECT applications, Capintec
can provide custom shielding for any of the hoods or enclosures
listed on these pages. Whether your requirement is for an eighth
of an inch of lead surrounding a work area or 2.38” (60 mm) of
PET thick shielding and an integral lead glass mobile body shield
for quality assurance or dose preparation, we can design custom
hood shielding to your specifications. If you are not sure of an
exact shielding design, contact Capintec for typical design
characteristics, specifications and pricing.
The photo on this page is a fully shielded Laminar Flow Hood
and Radioisotope Fume Hood. These units feature a mobile body
shield with lead glass, to view the working area while protecting
the worker. The mobile body shield can be moved to allow
replacement of filters and to service the hood. The mobile body
shield, although weighing several hundred pounds, moves
smoothly into place or out of the way. Our mechanical engineers
will be glad to work with you to design the product that suits
your application best.

Features
• Standard shielding is 1’ or 2” with custom shielding available
• Optional lead glass mobile body shield
• Flush mounting for dose calibrator ion chambers
• Environmental shielding for dose calibrator or other equipment
• 4’ (122 cm) and 6’ (183 cm) configurations available- Note

that dimensions vary with shielding selection
• NSF listed
• Optional UV lighting

ITEM NUMBERS
4’ Shielded A2 Bio-Safety Cabinet with Sliding L-block............ 5730-30342
4’ Shielded B2 Bio-Safety Cabinet with Sliding L-block............ 5730-30346
6’ Shielded A2 Bio-Safety Cabinet with Sliding L-block............ 5730-30350
6’ Shielded B2 Bio-Safety Cabinet with Sliding L-block............ 5730-30354

11

CAP-Cell® Isolator

The new Capintec CAP-Cell® Isolator is designed to provide an
ISO Class 5 (Class 100) clean air environment to meet the new
and more stringent requirements of USP <797> for aseptic sterile
compounding.

This shielded negative pressure recirculating isolator is the ideal
system for compounding and dispensing injectable Nuclear
Medicine radiopharmaceuticals. The unit incorporates a sealed
glove box and interchange chamber, with 1/8 inch (optional ¼
inch) of lead shielding to front door, sides, and floor. Additional
shielding on front face provides a full ¼ inch lead body shield. The
sealed isolator also eliminates the costly requirement for placement
in an exterior ISO Class 7 (Class 10,000) clean room. The standard
system uses HEPA filtered air with partial recirculation and room
air exhaust. This feature eliminates the need for HVAC hookup
and reduces operating costs. Optional external exhaust accessories
are available for HVAC hookup if desired. The model has a fully
hinged front panel to allow easy access for cleaning and equipment
placement. The sealed interchange chamber allows the user to
transfer materials without compromising the air quality of the
primary cell.

Isolator:
• Sealed glove box design with sealed interchange chamber
• Unit shall maintain ISO Class 5 (Federal Standard 209E Class

100) within workzone and interchange chamber
• Negative pressure, with sufficient interchange chamber pressure

differential to maintain sterility in glove box
• Interchange door is interlocked to prevent inadvertent opening

when outer door is open
• Two removable work trays with cove corners for main and

interchange chambers
• HEPA filter for supply air protected by non flammable

perforated metal diffuser
• HEPA filter seal is spring loaded Neoprene
• Partial re-circulating or total exhaust choice
• Externally mounted fluorescent lighting
• Hospital grade duplex outlet on back wall with drip proof cover
• Hinged front face, ergonomically slanted at 10° from vertical
• 16 GA, Type 304 stainless steel liner with reinforced U

channels
• Top/Front filter removal access without disassembly of control

panel
• Two 8 inch diameter glove ports

12

• Two circular nitrile rubber gloves DIMENSIONS
• Overall Dimensions: 51.5” w x 31” d x 80.5”- 90.5” h (130.8 x 78.7 x
• Two circular nitrile rubber sleeves
204.4 - 229.9 cm) , depending upon adjustable base setting
• Three position IV bar with six hooks • Workzone Dimensions: Main Cell 35.25” w x 23.25” d x 27.375” h (89.5 x

• Key locks included on external front face 59 x 69.5 cm)
Shielding/Base • Interchange Chamber Dimensions: 14.125” w x 24” d x 27.375” h (35.8 x

• Viewing window: 1/2 in. of 4.8 g/cm3 leaded glass, 25 in. 60.9 x 69.5 cm)
wide x 7 1/2 in. height • Interior sliding door: 18” w x 8.5” h (45.7 x 21.6 cm)
• Weight: 1/8” 1,200 lbs. (.3175 cm 544 kg), 1/4” option 1,600 lbs. (.635 cm
• 1/8 in. lead shielding on base, back and sides (optional 1/4
in.) 725.7 kg)

• 1/8 in. lead shielding on hinged front panel excluding glove ITEM NUMBERS
ports and viewing window CAP-Cell® with 1/8” lead.................................................................. 5530-3140
CAP-Cell® with 1/4” lead.................................................................. 5530-3141
• 1/4 in. lead body shield in center of front panel

• Base penetrations are sized for sharps container and flush
mount dose calibrator chamber

• 1/8 in. lead shielding for sharps container (Optional 1/4 in.)

• Articulating arm for calibrator readout mounted on base

• Exterior steel cosmetic panels painted epoxy enamel

• Heavy duty base support-adjustable height with 10 in. range

• Height adjustment to center of glove port-42 1/2 in. to 52
1/2 in.

• Electrical/Control Panel

• Exhaust interlock to prevent positive pressure workzone and
interchange

• Centrally located control panel for adjustable airflow and
lights

• Airflow adjustment via solid state motor voltage regulator

• Fuses located in control panel

• Two minihelic gauges

• Meets UL requirements for U.S. and Canada for electrical
safety

• UL/UL-C Listed 115 V, AC 60 Hz, 6 Amps (220V/50 Hz
option)

• 12 ft. Hospital Grade Power Cord

• Exhaust rate 65 CFM (110CMH) @ 0.1in. w.g. (external
exhaust option only)

Installation

• Unit is designed for customer installation

• Disassembled unit will fit through standard 36 in. doorway

• Base adjustment must be set before placing shielded glove
box

Options

• Thimble kit for external exhaust

• Additional lead shielding (1/4 in. total) on sides, floor, and
sharps shield

13

Radiation Fume Hoods

Radiation Fume Hoods in a wide variety of configurations are now
available from Capintec. The hoods are constructed of type 304
stainless steel and include an integral bottom with cup sink option.
The one piece interior is free of joints, cracks, or crevices which
prevents buildup of residue and simplifies decontamination
procedures. These radiation fume hoods can be configured for a
seated or standing working height. Because of the unique air flow
and accessory requirements that are typical for radiation fume hood
applications please contact Capintec to discuss your special needs.
• Capintec offers both shielded and standard configurations
• 4 and 6 foot widths available
• 1 and 2” lead shielding also available
• Custom configuration services available
• Optional integrated mobile lead glass work shields
• Three remotely controlled service fixtures
• Dedicated remote blower for superior exhaust characteristics

ITEM NUMBERS
Radiation Fume Hood 4 ft............................................................... 5300-0025

14

Elution Dispensing Safety Cabinet

This is an ideal solution for elution, compounding and dispensing
the SPECT or low activity PET drugs in a class 100 air
environment to comply with USP 797 regulations in an imaging
center, or unit dose distribution pharmacy.

• The internal chamber is SUS 316 stainless steel with round
concerns to prevent dust accumulation and chemical erosion.
The external body is carbon steel with epoxy painting.

• The working chamber is shielded by 5 mm thickness of lead,
the front top is shielded by lead glass.

• Two sliding lead glasses and two side foldable lead glasses are
equipped on the front of working area to prevent radiation
exposure to worker.

• A moveable generator cart with 50mm lead shielded is
equipped on front. It may accommodate two generators.

• A dose calibrator housing with 30 mm lead shielding is built
beneath the working level.

• The laminar flow with HEPA filter is equipped to meet the
IOS 5 air clearness (or Federal Standard 209E class 100).

• The exhausted air passes through a charcoal filter with 70%
recycled and 30% exchanged air.

• A touch control panel integrated all the functions is equipped
on front top.

• It accommodates dispenser MADD-3, ADS-100, 02-A201.

and Capintec are registered trademarks of Capintec, Inc. DIMENSIONS
• External Size: W 150 x D 90 x H 225 cm
• Internal Size: W 120 x D 70 x H 70 cm
• Weight: 750 kg
ITEM NUMBERS
Elution Dispensing Safety Cabinet................................................. 2500-6405

15


Click to View FlipBook Version