The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.

Ionising Radiations Safety Policy Page 5 of 60 Version 3 October 2011 page - 5 - the use of such equipment must be obtained from the HSE where the

Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by , 2016-06-25 04:03:03

Ionising Radiations Safety Policy - nuhrise.org

Ionising Radiations Safety Policy Page 5 of 60 Version 3 October 2011 page - 5 - the use of such equipment must be obtained from the HSE where the

APPENDIX I – TRAINING REQUIREMENTS FOR RADIATION USERS AND
THOSE WITH RADIATION PROTECTION RESPONSIBILITIES

Staff Group/QE Initial Training Update Training Compliance
RPA
RPA2000, HPC Assurance
MPE
6yrs relevant post- RPA2000 HoMPCE checks;
RAM Lead reg experience in
QE Waste RAM modality, HPC renewal every biennial HPC check
RPS
Course (as 5yrs
IRMER recommended by
Practitioner relevant RPA), CPD Line Manager who
5yrs experience in
IRMER Operator work area signs off CPD tells
Relevant specialist
IRMER Referrer medical training (+ HoMPCE; biennial
Radiation Worker IRMER course
(including those where required for HPC check
using RAM) non-FRCR or non-
Heads of Radiographer) Annual refresher HoS checks
Sections, Relevant specialist
Responsible training (+ IRMER run by RPAs certificates; RPA
Managers (under course where
Policy) required for non- Audits
FRCR or non-
Radiog) CPD Lead clinician in
Info via relevant clinical area/ HoS
induction OR Clinical Director
Induction training
by RPS; signing CPD Lead clinician in
LRs clinical area/ HoS
RPA briefing into OR Clinical Director
responsibilities
under Policy. Annual reminder Responsible
Manager
Annual refresher HoS
as CPD talk

Refresher when Responsible
Policy Manager
significantly
altered.

Ionising Radiations Safety Policy Page 51 of 60
Version 3
October 2011

Appendix J

Ionising Radiations Safety Policy

Procedure for control of diagnostic X-ray machines

This procedure forms a part of the Trust Ionising Radiations Safety Policy and
is written to be complimentary to the Management of Medical Devices Policy.

This procedure only covers the addition requirements above and beyond the
requirements of the following Trust Policies

Management of Medical Devices Policy
The Control of Contractors Policy

The general requirements of the above policies must still be followed.

1. Aims

To ensure that benefits to patients from the use diagnostic X-ray machines
are maximised and that the risks to patients and staff from their use are
minimised. This includes the procurement, commissioning and maintenance
of any such machine throughout its life cycle.

2. Definitions

Diagnostic X-ray machines are all X-ray emitting devices used for medical
diagnosis on patients.

Exclusions

Specimen Cabinets e.g. faxitrons.
Electron Microscopes
Radiotherapy treatment machines (the diagnostic X-ray component should
comply with this procedure).

RPA – Radiation protection adviser
MPE – Medical Physics Expert

Ionising Radiations Safety Policy Page 52 of 60
Version 3
October 2011

3. Introduction

3.1 The Department Clinical Lead or Head of Service will:

Put systems in place to ensure the procedures below are complied with and
ensure that adequate resources(staff time etc) are available to support them.

4. Procedures

4.1 Selection and procurement including

An RPA and an MPE must be consulted regarding the potential purchase of
X-ray machines prior to award of business and ideally at project inception.
This is to ensure that the units can be installed and operated safely and that
the risks and benefits to patients staff and public are controlled.

4.2 Installation

At the contract stage advice on the radiation safety of the installation should
be sought from the relevant RPA. The responsibility for radiation safety in the
installation area must be included at the contract stage using a control of
contractors’ agreement.

4.3 Commissioning (inc. critical examination, acceptance and baseline
testing).

Prior to clinical use the following processes must have taken place.

Critical examination – The RPA will advise on the nature of the critical
examination of the safety features of the X-ray unit. The critical examination is
the installers responsibility however they may contract with another to carry
out this task.

Acceptance – advise from the MPE must be sought on the nature and scope
of the tests required.

4.4. Optimisation

It is essential that the exposures used to image patients are optimised.
Advice on the optimisation of exposures should be sought from the MPE.

Ionising Radiations Safety Policy Page 53 of 60
Version 3
October 2011

4.5. Servicing and maintenance

The Trust control of contractors policy must be followed whenever service
agents from external organisations are working on site.

4.6 Quality assurance

Advice on the quality assurance(QA) programme must be sought from an
RPA. The system must document the following requirements

The roles and responsibilities for each element of the QA programme
The test protocols to be used and the frequencies of the tests to be
carried including patient dosimetry
Tests to be carried out following routine servicing and the requirement
to take advice from an MPE when a repair has been carried out.
The tolerances to be applied to each test
The action to be taken in the event of a test failure
The calibration of equipment

4.7 Managing faults

For each piece of equipment a log of faults should be available to the users.
The fault log should be able to track a fault from discovery through to closure
and document the dates and actions taken to achieve this.

4.8 Handover

Handover arrangements for occasions when an X-ray machine is to be

operated for the purposes of repair or maintenance must be in place. The
arrangements should be agreed with an RPS. The “Axrem” form for handover
and return to use should be used unless another method has been agreed

with an RPA. The handover procedures should be documented in the local

rules for the relevant area.

4.8 Equipment inventory and replacement

An equipment replacement programme should be in place for every unit of X-
ray equipment. Where the unit’s performance has deteriorated or the RPA
has advised that replacement should be considered a risk assessment for the
continued use must be completed. RPA advice on the risk scores must be
obtained.
An equipment inventory must be maintained. The inventory must contain
name of manufacturer,

model number

serial number or other unique identifier,

Ionising Radiations Safety Policy Page 54 of 60
Version 3
October 2011

year of manufacture
year of installation

4.9 Decommissioning

Any X-ray equipment to be decommissioned should either be removed by the
manufacturer/supplier or specialist advice on disposal should be obtained e.g.
by estates as the unit may contain hazardous materials. Please note that the
RPA is not able to provide this advice.

4.10 Training and competence

All staff required to operate X-ray equipment must be trained to use the
equipment or be directly supervised – see NUH medical devices training
policy.

4.11 Incidents

Incidents involving X-ray equipment should be reported using the standard
trust reporting policy. Where there is the potential for the incident to have
resulted in increased staff public or patient dose or the image quality obtained
using the equipment may have been sub optimal the incident should also be
reported to the RPS for the area who will in turn inform the RPA according to
the local rules.

5 Record keeping

The following records must be kept.

Record Minimum retention period

QA records 2 years

Handover documents 2 years

Commissioning documents 2 years beyond decommissioning date
Incidents Variable – RPA to advise

Training and competence 2 years beyond decommissioning date

records is suggested

Equipment inventory Ongoing record

Fault log 2 years beyond decommissioning date

Ionising Radiations Safety Policy Page 55 of 60
Version 3
October 2011

Appendix K Equality Impact Assessment Radiation Safety Policy

1. Name of Policy or Service: Radiation Safety Policy

2. Name of Responsible Manager: Dr. Stephen Fowlie

3. Name of person completing assessment: Dr. Derek Pearson

4. Date EIA Completed 10/3/11

5. Description and Aims of Policy/Service (including relevance to equalities)

The purpose of the policy is to ensure that the Trust complies with the
legislation that ensures the safe use of radiation and radioactive
materials within the Trust

6. Brief Summary of Research and Relevant Data

The law requires special arrangements to be put into place for radiation
workers under the age of 18 as well as pregnant and breast feeding
workers.

Some radiation work is required at a particular time of day so restricts
working patterns (e.g. early morning starts for Radiopharmacy
production)

Some radiation work is not suitable for staff with some disabilities even
taking into account possible adjustments. This will restrict staff with
disabilities applying for some jobs.

7. Methods and Outcome of Consultation

Radiation Safety Committee
Organisational Risk Committee

8. Results of Initial Screening or Full Equality Impact Assessment:

Equality Group Assessment of Impact
Age LOW
Gender LOW
Race None
Sexual Orientation None

Ionising Radiations Safety Policy Page 56 of 60
Version 3
October 2011

Religion or belief None
Disability LOW
Dignity and Human None
Rights
Working Patterns LOW
Social Deprivation None

9. Decisions and/or Recommendations (including supporting rationale)

See full impact assessment

10. Equality Action Plan (if required)

Arrangements are already in place to address the key issues from the
impact assessment

11. Monitoring and Review Arrangements (including date of next full review)

RPAs will audit implementation of the policy for these groups as part of
the annual audit review.

Next full review 2013

Ionising Radiations Safety Policy Page 57 of 60
Version 3
October 2011

Screening Grid Is this policy or Assessment of Potential Reasons for
Equality Area service Impact: Assessment
(Protected HIGH
Characteristics) RELEVANT to MEDIUM Special
this equality LOW arrangements for
Age area? workers under the
YES / NO NOT KNOWN age of 18 working
Disability positive (+) negative (-) with radiation
YES Staff with some
Gender Impact: disabilities would
Reassignment YES LOW be excluded from
Race radiation work
Religion or NO Impact:
Belief NO LOW
Sex NO
Impact: Special
Sexual YES LOW arrangements for
Orientation pregnant and
Marriage & Civil NO breastfeeding
Partnership NO staff
Pregnancy & NO
Maternity NO Impact: Some work with
Social NO LOW radioactive
Deprivation materials needs
Dignity and YES to be completed
Human Rights at particular times
Working
Patterns

Ionising Radiations Safety Policy Page 58 of 60
Version 3
October 2011

Full Impact Assessment Grid

Equality Area Key points of Does the polic
Breach equalities
(Protected research and legislation?
No
Characteristics) consultation No

from Screening No

Grid No

Age Lower radiation dose

limits set for workers

under the age of 18.

Disability Staff with some

disabilities would be

excluded from
radiation work –

making them not

suitable for certain

posts within the

Trust.

Sex The law requires the

Trust to put special

arrangements in

place for pregnant

and breast feeding

staff.

Working Some work with

Patterns radioactive materials

needs to be

completed at

particular times

Ionising Radiations Safety Policy
Version 3
October 2011

cy / service or its implementation: Key issues for action
[Will form basis of action
s Prevent Promote
plan]
discrimination or equality / good

inequality? relations?

No Yes Local Rules to include
special arrangements
where necessary

No No Review the requirements
of appropriate
adjustments if possible
as part of appointment
process

No Yes See Appendix E of the
policy
Local Rules to include
special arrangements
where necessary

No No Make working patterns
explicit on appointment

Page 59 of 60

APPENDIX L CERTIFICATION OF EMPLOYEE AWARENESS

Document Title IONISING RADIATIONS SAFETY POLICY
Version (number) 3
Version (date) October 2011

I hereby certify that I have:
Identified (by reference to the document control sheet of the above
policy/ procedure) the staff groups within my area of responsibility to
whom this policy / procedure applies.
Made arrangements to ensure that such members of staff have the
opportunity to be aware of the existence of this document and have the
means to access, read and understand it.

Signature

Print name

Date

Directorate/
Department

The manager completing this certification should retain it for audit and/or
other purposes for a period of six years (even if subsequent versions of the
document are implemented). The suggested level of certification is;

Clinical directorates - general manager
Non clinical directorates - deputy director or equivalent.

The manager may, at their discretion, also require that subordinate levels of
their directorate / department utilize this form in a similar way, but this would
always be an additional (not replacement) action.

Ionising Radiations Safety Policy Page 60 of 60
Version 3
October 2011


Click to View FlipBook Version