Dräger X-am 2500
Logistics
Dräger Dräger X-am 2500
X-am 2500 Flex
p/n 8323900 pre-configured
X-am 2500 Ex, O2, CO, NO2 Dräger X-am 2500 Ex
X-am 2500 Ex, O2, H2S-LC, SO2
X-am 2500 Ex, O2, CO, H2S-LC Dräger X-am 2500 Ex, O2
X-am 2500 Ex, O2, CO Dräger X-am 2500 Ex, O2, H2S-LC
X-am 2500 Ex, O2, H2S-LC
X-am 2500 Ex, O2 Dräger X-am 2500 Ex, O2, CO
X-am 2500 Ex Dräger X-am 2500 Ex, O2, H2S-LC, CO
X-am 2500 O2, CO, H2S-LC
X-am 2500 O2, CO
X-am 2500 O2, H2S-LC
make to order make to stock
Dräger X-am 2500 | Rüdiger Weich | March 2013 215
Dräger X-am 2500
The product
Dräger X-am 2500 Dräger X-am 2500
Flex (stock)
delivered with: delivered with:
- calibration certificate - calibration certificate
- country specific alarm levels - Default alarm levels
- further sensors expandable - not expandable
- selectable power pack - w/o power pack
- selectable variants (not sensors) - fixed variants
- selectable calibrations for Cat Ex
- customer specific settings
- w/o support CD - w/o support CD
- optional XXS SO2 sensor
with installed KX filter (H2S)
- selectable calibration intervall
(customer specific)
make to order make to stock
Dräger X-am 2500 | Rüdiger Weich | March 2013 216
Dräger X-am 2500
Differentiation / visual appearance
NE
W!
black silver silver
sensor grill sensor grill sensor grill
silver retro
black /grey
grey foil reflective
foil
foil
Dräger Dräger Dräger
X-am 2000 X-am 2500 X-am 5x00
Dräger X-am 2500 | Rüdiger Weich | March 2013 217
Dräger Gas Detection Technology : PAM
X-am 1700 X-am 2000 X-am 2500 X-am 5000 X-am 5600
Personal Air Monitoring
PAM
Numbers of sensors 4 1-4 1-4 1-5 1-6
Time limited
H S/CO/O /EX
2
2
NO/NO /SO /PH /HC only NO ,
2
2
3
2
N/NH /CO /Cl /OV/H SO 2
2
2
3
/Odorant/
2
Amine/COCl 2
IR Ex / IR CO 2
Cat Ex 125 PR
Ex Vol% 0-5 Vol% 0-5 Vol.% 0-5 Vol.% 0-5 und 0-100 0-5 und 0-100
Vol.% Vol.%
Ex Zone 2G/M2 2G/M2 1G/M1 1G/M1 1G/M1
Dräger Gas Detection Technology : PAM
X-am 1700 X-am 2000 X-am 2500 X-am 5000 X-am 5600
Numbers of sensors 4 1-4 1-4 1-5 1-6
Time limited
H S/CO/O /EX
2
2
NO/NO /SO /PH /HC only NO ,
2
2
2
3
N/NH /CO /Cl /OV/H SO 2
2
2
3
/Odorant/
2
Amine/COCl 2
IR Ex / IR CO 2
Cat Ex 125 PR
Ex Vol% 0-5 Vol% 0-5 Vol.% 0-5 Vol.% 0-5 and 0-100 0-5 and 0-100
Vol.% Vol.%
Ex Zone 2G/M2 2G/M2 1G/M1 1G/M1 1G/M1
Dräger X-am 2500 SP`s & USP´s
• Longest sensor life times
• 3 years warranty for standard gases and instrument
– to proove the longevity of our sensors
• Quickest testing & lowest gas consumption with X-dock
NO2 and SO2 sensor in a low cost instrument
- important for mining and refinery
• Zone 0; MED approval; Meas Perf. Approval
– Zone 0 for Industry and Mining => unique in the low cost market
– Shipping Industry approved low end 4 gas
– Meas. perf. Approval from Methane to Nonane => Refinery proof
220
PUMP FOR
X-AM 2500
ั
ี
อดตป๊ม
Multi-
gas detector
X-AM 3500 SERIES
X-AM 3500
https://www.youtube.com/watch?v=xN_Z6D2LPzU
®
Dräger X-am 3500
Sub Headline
Location, date, first name last name
®
Dräger X-am 3500 At a Glance
®
Dräger X-am 3500
Optimised for clearance measurement
®
The Dräger X-am 3500 was especially
designed for clearance measurements. The 1
to 4 gas detector reliably detects flammable
gases and vapours as well as O , CO, H S, NO
2
2
2
und SO . The innovative signaling design and
2
extensive range of accessories ensure
optimum safety and easy handling.
The device is extremely robust. For
easy readability, the device offers a
large colour display. The inductive
charging protects against wear and
tear and thus ensures a long lifespan.
®
Dräger X-am 3500
Features & Benefits
Switch easily between
Glowing D-Light indicates: pump and diffusion mode
tested and ready for use for flexible use
ZZZZZZ
Inductive charging Sensor slots
protects against wear and used to measure up to
tear four gases
®
Dräger X-am 3500
Deep Dive
Simple and safe
clearance measurement Efficient through
thanks to a powerful < Product picture > extensive fleet
pump and an extensive management
range of accessories
Specially designed for use with a pump Low operating costs
The Dräger X-am 3500 is equipped with a very powerful pump. Bumptest and calibration are carried out simply and quickly
It can be connected with hoses of up to 45 metres in length. A using the Dräger X-dock® calibrating station. Its low test
pump adapter makes it easy to switch between diffusion and gas consumption keeps operating costs to a minimum.
pump mode at any time. This means the pump is only operated
when you actually need it. That saves energy, reduces wear Its reporting function and numerous other useful features
and tear and thereby extends the lifespan of the pump. make the X-dock Manager PC software a smart addition to
any fleet management operation. To identify the devices in
the fleet, you can either use tried and tested barcodes or an
integrated RFID transponder.
Presentation title | first name last 237 | 16
name | 14.02.2018
®
Dräger X-am 3500
Models & Accessories
Models Z ZZZZZ Z ZZZZZ Z ZZZZZ Z ZZZZZ Z ZZZZZ
Dräger X-am 3500 Dräger X-am 8000
Measures up to 4 gases Measures up to 7 gases
Accessories
Inductive charger Pedestal and shoulder strap Protective rubber boot Dräger X-dock
with adhesive label
®
Dräger X-am 3500
Application Scenarios
Challenge:
Reliable measurement of
different gases
Confined Space Entry is one of the
highest risk activities around. Because
of the limited space and a lack of
ventilation, it is particularly relevant
whether hazardous gases are present.
A reliable clearance measurement is
required before entry.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
Solution: X-am 3500
®
Dräger X-am 3500
Application Scenarios
Challenge:
Reliable measurement of
different gases
Leakages can occur anywhere where
gases or liquids are stored or
transported. It is important to identify
them quickly in order to take appropriate
measures to prevent injuries to people,
and damages to the environment and
facility.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
Solution: X-am 3500
®
Dräger X-am 3500
Application Scenarios
Challenge:
Reliable measurement of
different gases
The sudden appearance of gas
concentrations during daily work can be
very dangerous. Therefore the ambient
air in some areas must be analysed
continuously. The challenge is to monitor
the work environment of many people at
one time.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
Solution: X-am 3500
®
Dräger X-am 3500
Extended Portfolio
Extended portfolio:
Appropriately respond to a variety of
hazards
Everything from one source: From single
gas over multi gas devices to a complete
area monitoring.
The X-am 3500 stands for simple and
X-zone 5500 safe clearance measurement with an
Area monitoring in innovative signaling concept and
X-am 2500/5X00 combination with X-am practical assistant functions.
1- to 5- gas detectors 5000/5600
for personal air monitoring X-am 8000
Mulitfunctional 1- to 7-
gas detection device for The development
clearance measurement, of integrated sensors
leak search and area is done almost exclusively at
X-am 3500 monitoring
Multifunctional 1- to 4- gas our headquarters in Lübeck.
detection device for clearance They stand for consistently
measurement, leak search high quality and reliability.
and are monitoring
®
Dräger X-am 3500
Technical Data
Alarm Clear optical alarm signal, visible through Safety Cost Produc-
coloured LEDs efficiency tivity
Loud acoustic alarm: Multi-tone, typically 100
dB(A) at 30 cm Clear visible alarm
Vibration alarm system for
reliable protection
Operating time (Diffusion) Depends on the sensor set up: between
approx. 24 h and up to 120 h
Handy thanks to
Dimensions (H x W x D) 179 x 77 x 42 mm low weight and
ergonomic design
Ingress protection class IP 67
Quick readiness
in emergency cases
Ready for measurement Typical: < 60 s for standard sensors
Presentation title | first name last 243 | 22
name | 14.02.2018
®
Dräger X-am 3500
Standards & Approvals
As a part of our safety portfolio, ATEX
the X-am 3500 has to fulfill legal (European Ex approval)
requirements and further requirements for
their industrial use (e.g. explosion IECEx
protection, electromagnetic compatibility). (International Ex approval)
Product quality also allows its use under MED / DNV GL*
harsh conditions, thus ensuring the device‘s (Shipping Approval)
reliability.
CSA C US* (Ex approval for USA and
Canada)
* EAC (Ex approval for Russia, Belarus
and Kazakhstan)
EAC
> 24 h 1 - 4 CSA & C US ATEX / IECEx
Battery life (diffusion mode) out of 6 sensors selectable
IECEx
®
Dräger X-am 3500
Markets we are in
Chemical Oil & Gas
Industry Industry
Shipping Pharma-
ceutical
Industry
Fire Services Water
Treatment
Presentation title | first name last name 245 | 16
| 14.02.2018
X-AM 8000
https://www.youtube.com/watch?v=p6Qt9eDfcMw
®
Dräger X-am 8000
ู
ึ
®
Dräger X-am 8000 At a Glance ใช้ได้สงถง 7 gas detector sensor
®
Dräger X-am 8000
Optimised for clearance measurement
Clearance measurement has never been this
easy and convenient: The
Dräger X-am® 8000 measures up to seven
toxic as well as flammable
gases, vapours and oxygen all at once —
either in pump or diffusion mode. Innovative
signaling design and handy assistant
functions ensure
complete safety throughout the process.
The device is extremely robust. For
easy readability, the device offers a
large colour display. The inductive
charging protects against wear and
tear and thus ensures a long lifespan.
Presentation title | first name last 248 | 16
name | 07.06.2017
®
Dräger X-am 8000
Features & Benefits
Switch easily between
Glowing D-Light indicates: pump and diffusion mode
tested and ready for use for flexible use
Assistants for
clearance measure-
ment, leak detection
and benzene-specific
testing with the PID Five sensor slots
(pre-tube) ensure easy ZZZZZZ used to measure up
handling to 7 gases
®
Bluetooth module
allows communication and Inductive charging
data exchange with other protects against wear and
systems tear
®
Dräger X-am 8000
Deep Dive
Simple and safe Efficient through
clearance measure-ment extensive fleet
thanks to assistant and < Product picture > management
CSE Connect/ Bluetooth®
Assistant function and app connection Low operating costs
The X-am 8000 effectively supports various applications with Bumptest and calibration are carried out simply and quickly
specially developed assistant functions that guide you through using the Dräger X-dock® calibrating station. Its low test
each process step by step. During clearance measurement, for gas consumption keeps operating costs to a minimum.
example, the smart assistant calculates the necessary flooding
time based on different parameters. Its reporting function and numerous other useful features
make the X-dock Manager PC software a smart addition to
With the app and cloud solution CSE Connect, specially any fleet management operation. To identify the devices in
developed for the X-am 8000, measured values can be trans- the fleet, you can either use tried and tested barcodes or an
ferred automatically via an optional Bluetooth® connection to integrated RFID transponder.
the app. Additionally, measuring jobs can be quickly and easily
transmitted to the app using an online application.
®
Dräger X-am 8000
Models & Accessories
Z
Models Dräger X-am 8000 Z Dräger X-am 3500 Z ZZZZZ Z ZZZZZ Z ZZZZZ
ZZZZZ
ZZZZZ
Measures up to 7 gases Measures up to 4 gases
Accessories
Inductive charger Base (Pedestal) Protective rubber boot Dräger X-dock Pre-tube holder
®
Dräger X-am 8000
Why Dräger?
Optimised for » The Dräger X-am 8000 has been developed in close collaboration with users. The result is a
01 practical use » Useful assistant functions
device with high practical customer usage.
Easy to use » 3 button operation concept, signal system based on a clear colour code
02 » Impact detection informs about severe mechanical stresses that might result in functional
impairments
Low operating costs » Durability of sensors and devices
03 » Low maintenance effort
» Low gas consumption during the functional test
> 250 Customer contacts in the development phase of > 35 various sensors can be used
the Dräger X-am 8000
years of experience
> 70 in development of > 150
different gases can be measured
gas detection devices
®
Dräger X-am 8000 Application Scenarios
Challenge:
Reliable measurement of
different gases
Confined Space Entry is one of the
highest risk activities around. Because
of the limited space and a lack of
ventilation, it is particularly relevant
whether hazardous gases are present.
A reliable clearance measurement is
required before entry.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
4 PID detection with pre-tube
Solution: X-am 8000
®
Dräger X-am 8000 Application Scenarios
Challenge:
Reliable measurement of
different gases
Leakages can occur anywhere where
gases or liquids are stored or
transported. It is important to identify
them quickly in order to take appropriate
measures to prevent injuries to people,
and damages to the environment and
facility.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
4 PID detection with pre-tube
Solution: X-am 8000
®
Dräger X-am 8000 Application Scenarios
Challenge:
Reliable measurement of
different gases
The sudden appearance of gas
concentrations during daily work can be
very dangerous. Therefore the ambient
air in some areas must be analysed
continuously. The challenge is to monitor
the work environment of many people at
one time.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
4 PID detection with pre-tube
Solution: X-am 8000
®
Dräger X-am 8000 Application Scenarios
Challenge:
Reliable measurement of
different gases
In many companies, benzene vapours
can hardly be avoided. The right
measurement strategy and precise
monitoring with PID can contribute to
avoiding work-related cancer due to
benzene vapours.
1 Clearance Measurement
2 Leak Search
3 Area Monitoring
4 PID detection with pre-tube
Solution: X-am 8000
®
Dräger X-am 8000
Extended Portfolio
Extended portfolio:
Appropriately respond to a variety of
hazards
Everything from one source: From single
gas over multi gas devices to a complete
area monitoring.
The X-am 8000 stands for simple and
X-zone 5500 safe clearance measurement with an
Area monitoring in innovative signaling concept and
Pac combination with X-am practical assistant functions.
3500/5500/7000 5000/5600
single-gas detection X-am 8000
devices Multifunctional 1- to 7-
gas detection device The development
for clearance of integrated sensors
measurement, leak is done almost exclusively at
X-am 2500/5X00 search and area
1- to 5- gas detectors for monitoring our headquarters in Lübeck.
personal air monitoring They stand for consistently
high quality and reliability.
®
Dräger X-am 8000
Technical Data
Alarm Clear optical alarm signal, visible through Safety Cost Produc-
coloured LEDs efficiency tivity
Loud acoustic alarm: Multi-tone, typically 100
dB(A) at 30 cm Clear visible alarm
Vibration alarm system for
reliable protection
Operating time (Diffusion) Depends on the sensor set up: between
approx. 16 h and up to 120 h
Handy thanks to
Dimensions (H x W x D) 179 x 77 x 42 mm low weight and
ergonomic design
Ingress protection class IP 67
Various gas
combinations for
Sensor options (slots) Combination of sensors: 1 PID- or IR-Sensor, 2 high safety and
IR- or CatEx sensors, 3 – 5 EC sensors flexible use
Quick readiness
Ready for measurement Typical: < 60 s for standard sensors in emergency cases
®
Dräger X-am 8000
Standards & Approvals
As a part of our safety portfolio, ATEX
the X-am 8000 has to fulfill legal (European Ex approval)
requirements and further requirements for
their industrial use (e.g. explosion
protection, electromagnetic compatibility). IECEx
(International Ex approval)
Product quality also allows its use under
harsh conditions, thus ensuring the device‘s MED / DNV GL*
reliability. (Shipping Approval)
CSA C US* (Ex approval for USA and
* Canada)
7 > 150 CSA & C US ATEX / IECEx
gases can be measured simulta- different gases can be measured
neously with the Dräger X-am 8000 with the Dräger X-am 8000
IECEx
*please contact Dräger regarding availability
Presentation title | first name last 259 | 16
name | 07.06.2017
®
Dräger X-am 8000
Markets we are in
Chemical Oil & Gas
Industry Industry
Shipping Pharma-
ceutical
Industry
Fire Services Water
Treatment
Dräger X-am 3500 and 8000 - How to use (all chapters)
https://www.youtube.com/watch?v=xN_Z6D2LPzU
Dräger X-am 8000 - Clearance Measurement
https://www.youtube.com/watch?v=p6Qt9eDfcMw
Dräger Gas Detection Technology LS
Leak Search
Leak Detection
•Leakages can occur wherever gases or liquids are
stored or transported. It is important to identify
leakages quickly, so that the appropriate measures
can be taken to avoid harm to people, the
environment and the facility.
•Detection devices combined with corresponding
pumps must be able to respond quickly so as to
detect small changes in concentration. High levels
of reliability are another minimum requirement
for these measuring instruments.
Overview Portable Gas Detection | Gas Detection | March 2013 263 | 26
LS
Dräger Gas Detection Technology Leak Search
Leak Detection Multi PID 2 X-am 7000
Numbers of sensors 1 1-5
H2S/CO/O2
Special gases e.g..
Cl2/HCN/NH3/NO2/PH3/SO2/
NO/OV/OV-A ...
IR Ex / IR CO2
Cat Ex
PID für VOC´s
IP class protection IP 67
Response time > 2 sec t90 >15 sec (PID)
Ideal for: Quick leak detection of Multigas Leak detection
VOC´s incl. VOC´s
264 | 26