Ma. Lynnor O. Pinca
REBL No.: 0000354 Valid until 11/03/21
DHSUD No.: 000088 Valid until 12/31/20
Tel No.: 09175045091
www.amaialand-asc.com
FREQUENTLY ASKED
QUESTIONS
How much is the construction bond?
P10,500 for interior renovation/repairs and
P21,000 for exterior renovation/repairs
How much is the move-in fee?
None
Association dues? And what are the
inclusions of the association dues?
No established rate yet.
Inclusions include: security, maintenance,
garbage collection, payment for property
management, streetlights, RPT, etc.
Who is the utilities provider on the area?
Meralco, Laguna Water, Globe, PLDT
Is the water and Meralco included in the
other charges?
Not Included.
How much is the estimated/expected cost for
Laguna Water and Meralco application and
installation process?
For Laguna Water it is P7,840 while for Meralco it is P6,500.
But this might be subject to change given that these rates
are as of 2020.
What are the commercial, establishments
inside?
Inside Nuvali Estate are the following:
Solenand, S&R, Landmark
Magnitude that the building can handle?
Magnitude 8
What are the construction materials
used?
Load Bearing Wall System
Waste management system?
MRF (Materials Recovery Facility) is provided.
It is divided in 3 areas - wet, dry and hazardous.
How many units in Series Nuvali?
Sector 1 – 253 Units
It is possible to combine the unit in pre
selling stage?
Yes, we have predetermined units that can be combined.
We highly recommend combining of units at this stage
in order to finalize all construction plans to avoid any
complications..
What if the buyer wants to combine the unit but
the unit are constructed already it is possible to
combine it?
Possible but buyer needs to have an approved structural plan.
Warranties from Amaia will be void.
Can buyer put fence? What are the restrictions?
Yes, buyer can construct his own fence,
following the restrictions:
• 2m maximum fence height
• 1m maximum concrete
• 1m minimum see-through
• no encroachments are prohibited.
Difference between Vermosa Series and Nuvali?
1. Floor Plan (Living Area, Dining, Kitchen, T&B, Bedrooms
and hallways)
2. Stair Design and Location
3. Façade (additional accent and heightened exterior colors)
4. Less number of units per cluster
5. Bigger open space and greeneries
STAIR REVISIONS
END UNIT STAIRS ISOMETRIC
VERMOSA STAIR REVISIONS
• STAIR WIDTH FROM
800mm TO 915mm
• STAIR TREAD FROM
300mm TO 280mm
(ADJUSTED IN ORDER
TO RETAIN THE 3
BEDROOM LAYOUT)
• STAIR RISER FROM
193mm TO 180mm
• WINDING STAIRS ,
TREAD DEPTH 150mm
MINIMUM AND
280mm @ 305mm
FROM NARROWEST
PORTION
• STAIR ENTRY RE-
ORIENTED
• FROM 14 STEPS TO 16
STEPS
NUVALI
INNER UNIT STAIRS ISOMETRIC
VERMOSA STAIR REVISIONS
• STAIR WIDTH FROM
800mm TO 915mm
• STAIR TREAD FROM
300mm TO 280mm
(ADJUSTED IN ORDER
TO RETAIN THE 3
BEDROOM LAYOUT)
• STAIR RISER FROM
193mm TO 180mm
• WINDING STAIRS ,
TREAD DEPTH 150mm
MINIMUM AND
280mm @ 305mm
FROM NARROWEST
PORTION
• STAIR ENTRY RE-
ORIENTED
• FROM 14 STEPS TO 16
STEPS
NUVALI
FLOOR PLANS
END UNIT GROUND FLOOR PLAN
PROPOSED
ADDITIONAL AREAS
• BREAKFAST NOOK
• STUDY NOOK
• STORAGE UNDER
STAIRS
• 59 SQM. FLOOR
AREA
VERMOSA NUVALI
END UNIT SECOND FLOOR PLAN
REVISIONS
• WIDER STAIRS AND
HALLWAY
• VARIATION OF
BEDROOM SIZES
• T&B LAYOUT
VERMOSA NUVALI
INNER UNIT GROUND FLOOR PLAN
REVISIONS
• RELOCATION OF
SERVICE DOOR
AND WINDOW
FOR BIGGER
KITCHEN AND
SERVICE AREA
• SAME LAYOUT
VERMOSA NUVALI
INNER UNIT SECOND FLOOR PLAN
REVISIONS
• MASTER
BEDROOM WITH
OWN T&B
• REGULAR T&B
LAYOUT
VERMOSA NUVALI
FACADE
FACADE
VERMOSA REVISIONS
• 1m TOP FIREWALL
EXTENSION
• ADDITIONAL
ACCENT WALL ON
INNER UNITS
• PAINT COLORS
NUVALI
OTHER ITEMS