The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by trefferindia, 2019-11-15 10:24:42

TPSS_MV AIR CORE REACTOR

TPSS_MV AIR CORE REACTOR

PQ

MV AIR CORE REACTOR

Treffer Power System Solution Pvt Ltd

Off. Gat No.1838 Dehu-Alandi Road Chikhali Pune-411062
Email :psbisale@trefferindia.com,
Phone no. +919822401714

+918408877788
www.trefferindia.com, www.trefferpower.com

ISO 9001 & 14001 Certified Company

Treffer Air-Core Reactors provide a linear response of impedance versus current which is
essential for numerous applications. The dry type design is maintenance free and
environmentally friendly.

TREFFER has an experienced team of reactive power compensation specialists able to provide customised
solutions to meet special customer needs, more than 20 year of experience in field

Manufacturing : For encapsulated design, the conductors are
mechanically immobilised and encapsulated by
Treffer reactor windings consist of numerous epoxy impregnated fibreglass filaments forming
aluminium or copper conductors connected in cylinders. Depending on the reactor ratings, one or
parallel. these conductors can be insulated single more of these cylinders are connected in parallel
wires, insulated cables or aluminium profiles separated between aluminium or copper spiders. the individual
by fibreglas spacers. the cost-effective solution to be cylinders are separated by fibreglas spacers forming
selected, in terms of dimensions and conductor type
to be used in each design, depends on the required cooling ducts. . F- 155°C & H-180°C Class
ratings for the equipment.

Quality Assurance : We have in house Testing facilities As per IS/IEC

At Treffer, a continuous quality improvement system is • HV Testing up to 70KV
in place based on the constant quest for optimised • Digital Megger 1-5KV
product design, procurement of materials and • Digital Milliohm Meter
components, production and customer service. • Digital L-C-R Bridge
Products assembled by an experienced and well- • Digital DB meter
trained workforce , we modern equipment's to • Thermography up to 250deg
determine the Guaranteed parameter, we have online • Laser temperature Gun - 250 deg
in process test records ensure the design data will be • Load test up to 150 Amp ( Temp rise test)
verified at the initial stage itself,We have Separate Lab
for test the finish Goods

Specifications :

Specification IS-5553-1990 / IEC 60070
Frequency 50 Hz / 60HZ
Resonance Frequency 0.2/ 2/4/6/7/14 % & Tuned 2nd/3rd/5th/7th/11th/13th
Capacitor Voltage 0.69Kv/1.1KV/3.3KV/6.6/11KV/20K/2002KV/33KV/66KV
Protection Degree IP-00
Output in Kvar from 5 KVAR to 200 KVAR
Type Air core Aluminum / Copper Wound
Rated Current Up to 450 A

Installation :

Treffer reactors are suitable for either indoor or
outdoor installation.

Reactors are often installed in existing substations
or installed to replace existing reactors. Treffer can
design reactors to fit inside space limitations or to
be mounted directly onto the existing foundations.
Treffer can also design reactors for use inside
enclosures. In this case, the reactors are designed
to avoid excessive heating.

A Mounting arrangement
Reactors can be mounted individually as single-
phase units, side-by-side, or as three-phase stacks,
one coil on top of the other. Special mounting
arrangements can be offered in case of space
limitations. Figure 2&4 illustrates options available.


A Magnetic Clearance
Treffer basic guidelines for magnetic clearances are
shown in figure 3.



SVC (static Var compensation)

sVc applications are used to provide dynamic voltage stabilization, improve
synchronous stability and operate as steady-state voltage support. the sVc can
also be required for dynamic load balancing in industrial installations using
large electrical motors and other equipment with variable loads. typical
applications include steel works (steel mills, cranes, arc-furnaces), paper mills,
mining companies, etc.)

sVc systems provide dynamic power compensation for utilities and industry
networks. the main benefits include dynamic voltage support, improvement of
system stability, power oscillation damping, reactive power balancing, flicker
control and reduction of losses. sVc normally consists of

a combination of thyristor-controlled reactors (tcr), thyristor-switched
capacitors and reactors (tsc and tsr), mechanically-switched capacitor banks
(msc) and harmonic filters (HF).

Treffer mfg All the MV reactor in accordance with IS/IEC STD. And Supplied Almost 1000 Nos Reactor in the field for various
industries in India & abroad past 20 year , We have Type Tested IN ERDA for 6.6KV/11KV/33KV Category


Click to View FlipBook Version